SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8066 WMO= 1901608


Cycle 212 GMT 15/ 2/2017 13:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.28 48 10.15 442 7 7
2 1214.00 150 5.84 1828 7 7
3 1160.08 30 6.25 1719 7 7
4 1085.76 30 6.23 1648 7 7
5 985.32 30 6.60 1509 7 7
6 876.72 30 6.91 1381 7 7
7 745.56 30 7.43 1227 7 7
8 191.56 30 9.70 520 7 7
9 -0.00 30 10.57 264 7 7
10 -0.04 180 10.53 267 7 11

Cycle 211 GMT 5/ 2/2017 19: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.24 47 10.28 442 7 7
2 1223.88 150 6.26 1828 7 7
3 1167.80 30 6.37 1751 7 7
4 1074.24 30 6.66 1642 7 7
5 961.60 30 6.98 1497 7 7
6 838.04 30 7.25 1366 7 7
7 423.28 30 8.95 821 7 7
8 32.32 30 10.51 303 7 7
9 16.84 30 10.53 283 7 7
10 -0.04 181 10.61 260 7 10

Cycle 210 GMT 27/ 1/2017 0:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 46 10.28 461 7 7
2 1051.32 1 7.66 1576 7 7
3 1253.32 150 6.45 1887 7 7
4 1176.60 30 6.73 1776 7 7
5 1076.36 30 6.90 1651 7 7
6 958.08 30 7.42 1480 7 7
7 692.96 30 8.33 1148 7 7
8 138.64 30 10.13 454 7 7
9 0.12 30 10.74 261 7 7
10 0.04 180 10.68 257 7 12

Cycle 209 GMT 17/ 1/2017 6: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.24 44 10.41 442 7 7
2 1089.12 2 7.03 1692 7 7
3 1630.88 150 5.87 2350 7 7
4 1558.24 30 6.19 2235 7 7
5 1472.72 30 6.28 2140 7 7
6 1375.12 30 6.38 2060 7 7
7 1261.76 30 6.88 1858 7 7
8 1135.96 30 7.07 1720 7 7
9 736.96 30 8.21 1235 7 7
10 200.20 30 10.01 553 7 7
11 0.12 30 10.67 295 7 7
12 0.08 180 10.59 318 7 8

Cycle 208 GMT 16/ 1/2017 5:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 43 10.54 442 7 7
2 1109.12 2 7.41 1769 7 7
3 1289.28 150 6.94 1924 7 7
4 1196.16 30 7.36 1781 7 7
5 1071.48 30 7.51 1653 7 7
6 811.68 30 8.17 1332 7 7
7 255.12 30 10.01 595 7 7
8 0.24 30 10.78 261 7 7
9 0.20 180 10.75 262 7 14

Cycle 207 GMT 6/ 1/2017 11:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.92 45 10.47 442 7 7
2 1246.16 150 7.28 1870 7 7
3 1140.76 30 7.56 1736 7 7
4 1012.76 30 7.93 1570 7 7
5 597.48 30 9.11 1046 7 7
6 74.16 30 10.56 361 7 7
7 0.08 30 10.81 261 7 7
8 0.04 180 10.78 264 7 18

Cycle 206 GMT 27/12/2016 17:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.40 44 10.60 461 7 7
2 1044.36 1 7.98 1692 7 7
3 1254.92 150 7.35 1890 7 7
4 1144.76 30 7.81 1731 7 7
5 1016.56 30 8.07 1578 7 7
6 453.92 30 9.56 864 7 7
7 10.04 30 10.79 267 7 7
8 0.20 30 10.81 267 7 7
9 0.24 180 10.78 271 7 11

Cycle 205 GMT 17/12/2016 23:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.20 43 10.66 442 7 7
2 1065.00 1 8.18 1634 7 7
3 1259.52 150 7.56 1888 7 7
4 1140.00 30 7.98 1741 7 7
5 742.44 30 8.81 1238 7 7
6 193.64 30 10.26 536 7 7
7 0.12 30 10.85 267 7 7
8 0.04 180 10.81 266 7 9

Cycle 204 GMT 8/12/2016 4:51:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.48 43 10.60 461 7 7
2 1585.24 150 7.15 2302 7 7
3 1460.48 30 7.59 2106 6 7
4 1085.60 30 8.18 1675 6 7
5 695.88 30 9.08 1193 7 7
6 415.76 30 9.68 868 7 7
7 19.76 30 10.75 315 7 7
8 -0.12 30 10.81 316 7 7
9 0.28 180 10.74 325 7 19

Cycle 203 GMT 7/12/2016 4:34:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 41 10.47 480 7 7
2 1076.68 1 7.98 1750 7 7
3 1249.96 150 7.75 1885 7 7
4 998.52 30 8.49 1552 7 7
5 732.92 30 8.92 1249 7 7
6 160.36 30 10.38 498 7 7
7 8.68 30 10.83 275 7 7
8 -0.00 30 10.85 272 7 7
9 0.04 180 10.80 285 7 10

Cycle 202 GMT 27/11/2016 10:26:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.36 44 10.73 442 7 7
2 965.92 -1 10.73 442 7 7
3 1222.92 150 7.98 1847 7 7
4 963.56 30 8.62 1525 7 7
5 555.56 30 9.46 1007 7 7
6 20.68 30 10.76 297 7 7
7 -0.00 30 10.86 270 7 7
8 -0.12 180 10.79 288 7 14

Cycle 201 GMT 17/11/2016 16:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.04 46 10.73 461 7 7
2 954.16 -1 10.73 461 7 7
3 1151.72 150 8.21 1758 7 7
4 885.36 30 8.80 1432 7 7
5 333.80 30 9.96 741 7 7
6 13.96 30 10.78 299 7 7
7 -0.04 181 10.82 283 7 16

Cycle 200 GMT 7/11/2016 22:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.00 46 10.66 442 7 7
2 1151.68 150 8.29 1762 7 7
3 739.80 30 9.16 1252 7 7
4 332.00 30 10.05 731 7 7
5 11.16 30 10.82 291 7 7
6 -0.00 30 10.85 280 7 7
7 -0.04 180 10.78 306 7 11

Cycle 199 GMT 29/10/2016 4:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 41 10.73 442 7 7
2 1091.00 2 8.24 1750 7 7
3 1629.44 150 7.59 2371 7 7
4 1374.24 30 7.96 2079 6 7
5 1102.44 30 8.64 1720 7 7
6 675.80 30 9.36 1188 7 7
7 220.44 30 10.38 598 7 7
8 8.52 30 10.80 319 7 7
9 0.20 30 10.77 341 7 7
10 -0.00 180 10.78 334 7 16

Cycle 198 GMT 28/10/2016 4:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.88 38 10.73 423 7 7
2 1137.24 3 8.43 1769 7 7
3 1141.24 150 8.45 1770 7 7
4 45.88 30 10.75 348 7 7
5 0.12 30 10.85 311 7 7
6 0.16 180 10.78 334 7 10

Cycle 197 GMT 27/10/2016 13:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.56 45 10.66 461 7 7
2 1222.80 150 8.27 1853 7 7
3 822.24 30 9.13 1347 7 7
4 408.44 30 9.98 823 7 7
5 21.16 30 10.83 303 7 7
6 -0.00 30 10.95 267 7 7
7 -0.08 180 10.88 276 7 10

Cycle 196 GMT 17/10/2016 19:38:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 44 10.66 442 7 7
2 1059.24 1 9.26 1653 7 7
3 1253.84 150 8.30 1897 7 7
4 978.24 30 8.95 1547 7 7
5 273.48 30 10.39 634 7 7
6 0.20 30 10.92 273 7 7
7 0.12 180 10.89 275 7 18

Cycle 195 GMT 8/10/2016 1:34: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.48 41 10.79 442 7 7
2 1109.56 2 9.26 1673 7 7
3 1275.56 150 8.34 1928 7 7
4 1010.52 30 8.94 1590 7 7
5 579.12 30 9.72 1047 7 7
6 19.36 30 10.88 291 7 7
7 0.16 30 10.96 267 7 7
8 0.16 180 10.85 297 7 17

Cycle 194 GMT 28/ 9/2016 9: 8:14

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.84 35 10.66 461 7 7
2 1252.56 6 8.18 1980 6 7
3 1707.52 150 7.45 2466 7 7
4 1578.52 30 7.81 2323 6 7
5 1171.32 30 8.60 1832 6 7
6 628.40 30 9.51 1148 7 7
7 186.36 30 10.49 561 7 7
8 0.24 30 10.87 316 7 7
9 1.28 180 10.81 335 7 12

Cycle 193 GMT 27/ 9/2016 8:41:28

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.28 35 10.66 461 7 7
2 1140.48 3 8.43 1807 7 7
3 1221.60 150 8.30 1872 7 7
4 95.00 30 10.66 422 7 7
5 0.12 30 10.87 311 7 7
6 0.08 180 10.77 334 7 17

Cycle 192 GMT 26/ 9/2016 17:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 38 11.05 480 7 7
2 1128.12 3 10.22 1730 7 7
3 1278.08 150 7.84 1923 7 7
4 1151.80 30 8.30 1764 6 7
5 733.20 30 9.24 1243 7 7
6 62.36 30 10.68 361 7 7
7 -0.12 30 10.92 259 7 7
8 -0.16 180 10.84 278 7 10

Cycle 191 GMT 17/ 9/2016 1:23:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.56 35 12.12 461 7 7
2 1098.64 2 11.18 1788 7 7
3 1271.88 150 4.51 2110 7 7
4 1397.80 30 8.18 2074 6 7
5 1470.12 30 7.88 2182 6 7
6 1439.64 30 8.11 2137 6 7
7 1367.44 30 8.44 2034 7 7
8 1260.84 30 8.68 1904 6 7
9 1129.40 30 9.02 1720 7 7
10 557.32 30 10.13 1009 7 7
11 -0.00 181 11.25 274 7 9

Cycle 190 GMT 7/ 9/2016 5:35:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.92 34 12.89 480 7 7
2 1047.56 1 11.11 1711 7 7
3 1237.32 150 7.96 1872 7 7
4 968.32 30 9.86 1550 7 7
5 280.20 30 11.48 664 7 7
6 0.08 181 11.99 296 7 10

Cycle 189 GMT 28/ 8/2016 11:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.16 33 12.82 519 7 7
2 1066.56 1 11.81 1692 7 7
3 1585.12 150 9.31 2346 7 7
4 672.16 30 10.90 1220 7 7
5 20.56 30 12.88 361 7 7
6 0.04 30 12.82 360 7 7
7 0.12 180 12.26 360 7 14

Cycle 188 GMT 27/ 8/2016 11:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.12 34 13.46 500 7 7
2 1210.48 150 6.02 1824 7 7
3 1161.24 30 9.53 1791 7 7
4 1039.80 30 9.78 1655 7 7
5 627.52 30 11.10 1132 7 7
6 -0.04 30 13.62 305 7 7
7 -0.12 180 12.73 307 7 14

Cycle 187 GMT 17/ 8/2016 17:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.52 34 13.78 500 7 7
2 1212.12 153 4.48 1910 7 7
3 1361.04 30 8.98 2039 6 7
4 1432.48 30 8.99 2127 6 7
5 1391.36 30 9.34 2082 6 7
6 1285.52 31 9.77 1949 6 7
7 1168.16 31 10.13 1828 7 7
8 596.76 31 12.16 1119 7 7
9 0.08 30 14.00 310 7 7
10 0.12 180 13.21 313 7 14

Cycle 186 GMT 7/ 8/2016 21:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.92 33 14.04 480 7 7
2 1227.04 150 5.64 1962 7 7
3 1293.76 30 9.54 1959 6 7
4 1221.36 30 10.03 1882 7 7
5 1100.12 30 10.54 1744 7 7
6 816.20 30 11.77 1385 7 7
7 0.24 30 14.09 311 7 7
8 0.16 180 13.50 321 7 20

Cycle 185 GMT 29/ 7/2016 3:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 35 13.85 519 7 7
2 937.32 -1 13.85 519 7 7
3 1175.48 150 7.68 1796 7 7
4 1073.56 30 10.54 1703 7 7
5 507.04 30 12.92 993 7 7
6 0.32 30 14.15 314 7 7
7 0.16 180 13.71 326 7 17

Cycle 184 GMT 19/ 7/2016 9:11:38

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.08 35 13.85 519 7 7
2 945.56 -1 13.85 519 7 7
3 1534.00 150 9.46 2268 7 7
4 766.12 30 12.56 1337 6 7
5 0.12 30 14.15 347 7 7
6 -0.00 181 13.48 383 7 12

Cycle 183 GMT 18/ 7/2016 9:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.20 34 13.72 538 7 7
2 1181.12 153 4.75 1905 7 7
3 1299.08 30 10.07 1975 7 7
4 1333.52 30 10.19 2039 6 7
5 1233.40 30 10.76 1909 7 7
6 964.64 30 11.82 1602 7 7
7 129.04 31 13.83 504 7 7
8 -0.12 181 13.88 316 7 21

Cycle 182 GMT 8/ 7/2016 14:11:36

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.28 35 13.85 519 7 7
2 1191.52 153 4.45 1856 7 7
3 1340.24 30 9.76 2046 7 7
4 1394.68 30 10.06 2108 7 7
5 1330.12 30 10.42 2078 7 7
6 1215.48 30 11.03 1916 7 7
7 658.24 30 12.73 1191 7 7
8 0.12 30 14.19 297 7 7
9 -0.04 180 14.04 298 7 27

Cycle 181 GMT 28/ 6/2016 18:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 35 14.04 480 7 7
2 1191.00 150 6.32 1798 7 7
3 1132.68 30 10.78 1772 7 7
4 1014.64 30 11.41 1637 7 7
5 433.96 30 13.26 882 7 7
6 0.60 30 14.28 286 7 7
7 0.04 180 14.21 284 7 31

Cycle 180 GMT 19/ 6/2016 0:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.00 35 14.04 480 7 7
2 1178.36 150 7.49 1795 7 7
3 1079.72 30 11.24 1714 7 7
4 500.44 30 13.19 975 7 7
5 30.12 30 14.20 327 7 7
6 0.08 30 14.30 289 7 7
7 -0.00 180 14.17 300 7 41

Cycle 179 GMT 9/ 6/2016 6:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.96 35 14.17 461 7 7
2 1556.08 150 9.24 2300 7 7
3 801.12 30 12.77 1405 7 7
4 81.40 30 14.07 432 7 7
5 0.04 30 14.27 331 7 7
6 -0.08 180 14.16 348 7 24

Cycle 178 GMT 8/ 6/2016 7: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 34 14.17 442 7 7
2 1223.36 153 4.47 1923 7 7
3 1365.64 30 10.37 2081 7 7
4 1421.60 30 10.59 2142 7 7
5 1340.44 30 11.00 2060 7 7
6 1217.56 31 11.50 1892 7 7
7 638.88 31 12.96 1166 7 7
8 68.24 31 14.09 393 7 7
9 0.04 30 14.26 292 7 7
10 0.12 180 14.24 297 7 31

Cycle 177 GMT 29/ 5/2016 11:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.60 35 14.10 442 7 7
2 1200.64 153 5.08 1920 7 7
3 1320.96 30 10.48 2015 7 7
4 1277.64 30 11.02 1948 7 7
5 1165.12 30 11.43 1823 7 7
6 743.44 30 12.71 1300 7 7
7 51.72 30 14.14 371 7 7
8 -0.16 181 14.25 291 7 13

Cycle 176 GMT 19/ 5/2016 16:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 35 14.10 480 7 7
2 1202.68 150 6.27 1854 7 7
3 1168.60 30 11.06 1824 7 7
4 1059.16 30 11.60 1688 7 7
5 501.56 30 13.26 965 7 7
6 14.64 30 14.16 313 7 7
7 0.08 181 14.28 286 7 27

Cycle 175 GMT 9/ 5/2016 22:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 35 14.23 461 7 7
2 1195.04 150 7.62 1831 7 7
3 1078.24 30 11.63 1716 7 7
4 372.64 30 13.55 796 7 7
5 0.24 30 14.26 286 7 7
6 0.08 181 14.27 288 7 22

Cycle 174 GMT 30/ 4/2016 4:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 35 14.04 500 7 7
2 1566.48 150 9.20 2295 7 7
3 837.12 30 12.74 1459 7 7
4 90.60 30 14.11 435 7 7
5 2.72 30 14.21 329 7 7
6 0.44 30 14.23 345 7 8
7 0.16 180 14.21 348 12 70

Cycle 173 GMT 29/ 4/2016 4:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 33 14.17 403 7 7
2 1040.44 1 10.66 1692 7 7
3 1245.36 153 4.57 1999 7 7
4 1387.56 30 10.62 2098 7 7
5 1435.92 30 10.88 2145 7 7
6 1345.24 31 11.27 2055 7 7
7 1214.92 30 11.86 1865 7 7
8 480.32 30 13.39 940 7 7
9 23.96 31 14.16 326 7 7
10 -0.12 30 14.26 291 7 7
11 -0.16 180 14.25 300 7 29

Cycle 172 GMT 19/ 4/2016 9:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.12 35 14.04 461 7 7
2 1201.32 151 5.47 1886 7 7
3 1286.56 30 10.65 1969 7 7
4 1219.52 30 11.22 1898 7 7
5 1101.88 30 11.67 1756 7 7
6 518.16 30 13.33 983 7 7
7 16.00 30 14.17 305 7 7
8 -0.00 181 14.29 280 7 12

Cycle 171 GMT 9/ 4/2016 14:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.68 35 14.04 461 7 7
2 1204.00 150 6.35 1876 7 7
3 1177.28 30 11.18 1810 7 7
4 1065.60 30 11.67 1704 7 7
5 504.88 30 13.22 978 7 7
6 0.16 30 14.19 294 7 7
7 0.20 180 14.25 290 7 18

Cycle 170 GMT 30/ 3/2016 20:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.92 35 14.17 461 7 7
2 1197.88 150 7.36 1820 7 7
3 1092.84 30 11.65 1722 7 7
4 413.32 30 13.47 844 7 7
5 47.92 30 14.13 350 7 7
6 0.08 30 14.22 288 7 7
7 -0.04 180 14.25 296 7 27

Cycle 169 GMT 21/ 3/2016 2:18: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.36 35 13.85 480 7 7
2 1570.24 150 9.09 2292 7 7
3 852.76 30 12.80 1459 7 7
4 114.40 30 14.03 475 7 7
5 0.20 30 14.24 316 7 7
6 0.08 180 14.24 342 7 19

Cycle 168 GMT 20/ 3/2016 2:20: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.32 35 14.04 461 7 7
2 966.84 -1 14.04 461 7 7
3 1226.56 153 5.31 1933 7 7
4 1332.76 30 10.82 2033 7 7
5 1270.72 30 11.38 1943 7 7
6 1152.00 30 11.84 1816 7 7
7 474.40 30 13.44 929 7 7
8 9.00 30 14.23 294 7 7
9 -0.12 30 14.28 283 7 7
10 0.12 180 14.26 295 7 37

Cycle 167 GMT 10/ 3/2016 7:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.60 35 14.04 461 7 7
2 1190.04 153 5.41 1897 7 7
3 1288.84 30 10.81 1973 7 7
4 1215.48 30 11.36 1908 7 7
5 1094.24 31 11.78 1767 7 7
6 503.20 31 13.32 975 7 7
7 34.88 31 14.17 332 7 7
8 0.12 30 14.26 288 7 7
9 0.04 180 14.23 306 7 33

Cycle 166 GMT 29/ 2/2016 12:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.68 35 14.10 461 7 7
2 1202.04 150 6.23 1863 7 7
3 1178.80 30 11.21 1847 7 7
4 1080.04 30 11.81 1715 7 7
5 523.36 30 13.21 1007 7 7
6 37.84 30 14.11 344 7 7
7 0.24 30 14.21 291 7 7
8 0.08 180 14.20 307 7 22

Cycle 165 GMT 19/ 2/2016 18:40: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.28 35 14.10 480 7 7
2 1184.80 150 7.23 1807 7 7
3 1091.32 30 11.67 1732 7 7
4 676.64 30 12.87 1212 7 7
5 48.24 30 14.11 360 7 7
6 0.92 180 14.23 299 7 19

Cycle 164 GMT 10/ 2/2016 0:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.00 35 14.04 480 7 7
2 1562.36 150 9.09 2287 7 7
3 705.88 30 13.03 1278 7 7
4 54.56 30 14.13 385 7 7
5 0.08 30 14.22 337 7 7
6 0.04 180 14.20 346 7 16

Cycle 163 GMT 9/ 2/2016 0:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.28 35 13.97 480 7 7
2 1197.00 153 5.12 1878 7 7
3 1312.24 30 10.87 2002 7 7
4 1266.60 30 11.46 1964 7 7
5 1157.40 31 11.98 1824 7 7
6 593.04 31 13.23 1092 7 7
7 48.00 30 14.07 360 7 7
8 0.08 181 14.26 291 7 13

Cycle 162 GMT 30/ 1/2016 6: 7: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.48 35 14.04 480 7 7
2 1211.64 153 5.49 1875 7 7
3 1291.56 30 10.83 1973 7 7
4 1221.72 30 11.56 1896 7 7
5 1091.64 30 12.12 1725 7 7
6 349.20 31 13.60 768 7 7
7 0.04 30 14.21 294 7 7
8 0.04 180 14.24 296 7 31

Cycle 161 GMT 20/ 1/2016 11:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 35 14.10 442 7 7
2 1197.12 151 6.05 1854 7 7
3 1191.36 30 11.29 1845 7 7
4 1087.60 30 11.84 1741 7 7
5 674.44 30 13.02 1188 7 7
6 34.84 30 14.10 335 7 7
7 0.12 30 14.21 286 7 7
8 -0.04 180 14.18 305 7 29

Cycle 160 GMT 10/ 1/2016 17:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.96 35 14.04 480 7 7
2 1196.84 150 7.39 1797 7 7
3 1095.12 30 11.77 1716 7 7
4 524.60 30 13.24 996 7 7
5 31.00 30 14.08 329 7 7
6 0.12 30 14.21 284 7 7
7 0.12 180 14.15 310 7 26

Cycle 159 GMT 31/12/2015 23:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.44 35 13.85 519 7 7
2 1584.80 150 8.98 2313 7 7
3 731.80 30 13.02 1299 7 7
4 60.92 30 14.06 400 7 7
5 0.04 31 14.23 331 7 7
6 -0.00 181 14.19 343 7 21

Cycle 158 GMT 30/12/2015 23:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 35 13.91 500 7 7
2 1216.32 151 5.74 1887 7 7
3 1275.96 30 11.14 1929 7 7
4 1190.48 30 11.82 1863 7 7
5 931.88 30 12.61 1534 7 7
6 91.00 30 14.02 412 7 7
7 0.20 30 14.23 283 7 7
8 0.08 180 14.23 293 7 26

Cycle 157 GMT 21/12/2015 4:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 35 14.04 480 7 7
2 1204.88 150 6.13 1878 7 7
3 1218.40 30 11.32 1885 7 7
4 1112.24 30 12.06 1740 7 7
5 563.20 30 13.26 1041 7 7
6 52.12 30 14.07 358 7 7
7 0.08 181 14.25 288 7 20

Cycle 156 GMT 11/12/2015 10:18: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.16 35 14.04 480 7 7
2 1201.52 150 6.85 1826 7 7
3 1132.56 30 11.68 1768 7 7
4 1000.68 30 12.28 1618 7 7
5 120.88 30 13.95 464 7 7
6 0.16 30 14.19 289 7 7
7 0.08 180 14.19 300 7 21

Cycle 155 GMT 1/12/2015 16:14:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.16 35 14.04 480 7 7
2 1204.40 150 7.84 1823 7 7
3 1080.64 30 11.98 1699 7 7
4 354.20 30 13.55 768 7 7
5 0.04 30 14.19 294 7 7
6 -0.08 180 14.20 288 7 29

Cycle 154 GMT 21/11/2015 22:18:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.24 35 13.97 480 7 7
2 1907.96 150 4.67 2673 7 7
3 1975.36 30 10.97 2885 7 7
4 1908.68 30 11.45 2767 6 7
5 1786.12 30 11.57 2679 7 7
6 1228.92 30 12.46 1930 7 7
7 648.36 30 13.23 1193 7 7
8 0.08 30 14.28 288 7 7
9 -0.04 180 14.31 299 7 19

Cycle 153 GMT 11/11/2015 23:42: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 35 14.10 461 7 7
2 1909.00 150 7.56 2820 7 7
3 1779.44 30 11.54 2581 6 7
4 1211.32 30 12.48 1895 6 7
5 354.80 30 13.70 778 7 7
6 0.12 30 14.26 294 7 7
7 0.20 180 14.28 308 7 21

Cycle 152 GMT 2/11/2015 1:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.40 35 14.10 461 7 7
2 1511.76 150 9.99 2231 7 7
3 293.72 30 13.78 701 7 7
4 0.20 30 14.19 318 7 7
5 0.20 180 14.16 346 7 10

Cycle 151 GMT 1/11/2015 2:10: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.76 35 14.10 461 7 7
2 1515.36 150 9.82 2216 7 7
3 453.84 30 13.50 929 7 7
4 20.80 30 14.14 342 7 7
5 0.04 30 14.20 342 7 7
6 0.04 180 14.16 345 7 41

Cycle 150 GMT 31/10/2015 2:42: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.72 35 14.10 480 7 7
2 1512.64 150 9.64 2220 7 7
3 442.56 30 13.52 911 7 7
4 0.08 181 14.16 345 7 10

Cycle 149 GMT 30/10/2015 3:22: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.56 35 13.97 480 7 7
2 1902.32 150 6.34 2961 7 7
3 1832.68 30 11.37 2645 7 7
4 1710.44 30 11.76 2512 6 7
5 1167.08 30 12.53 1847 7 7
6 289.24 30 13.77 685 7 7
7 0.04 181 14.24 319 7 20

Cycle 148 GMT 25/10/2015 13:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.68 35 14.04 480 7 7
2 1901.76 150 4.58 2373 7 7
3 1973.52 30 9.91 2831 6 7
4 1917.80 30 10.90 2794 6 7
5 1807.32 30 11.32 2648 6 7
6 1535.16 30 11.93 2331 6 7
7 807.84 30 13.05 1364 7 7
8 1.16 30 14.20 299 7 7
9 0.20 180 14.28 301 7 15

Cycle 147 GMT 15/10/2015 14:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.20 35 13.97 480 7 7
2 1901.96 150 4.60 2439 7 7
3 1970.52 30 10.15 2863 7 7
4 1919.80 30 11.07 2794 7 7
5 1811.72 30 11.49 2663 6 7
6 1254.24 30 12.36 1966 7 7
7 673.48 30 13.22 1209 7 7
8 0.08 30 14.26 283 7 7
9 0.04 180 14.28 304 7 17

Cycle 146 GMT 5/10/2015 15:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 35 14.04 480 7 7
2 1907.60 150 4.55 2284 7 7
3 1975.44 30 10.38 2840 6 7
4 1913.28 30 11.18 2768 6 7
5 1802.76 30 11.46 2680 6 7
6 1395.20 30 12.25 2121 7 7
7 663.24 30 13.25 1191 7 7
8 32.68 30 14.18 332 7 7
9 0.12 30 14.29 295 7 10
10 0.08 180 14.25 323 7 25

Cycle 145 GMT 25/ 9/2015 16:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 35 13.97 500 7 7
2 1903.68 152 4.50 2098 7 7
3 1978.44 30 10.78 2860 6 7
4 1907.36 30 11.31 2799 6 7
5 1779.24 30 11.65 2608 6 7
6 1228.64 30 12.41 1941 6 7
7 378.60 30 13.64 810 7 7
8 0.16 30 14.24 291 7 7
9 0.12 180 14.27 306 7 30

Cycle 144 GMT 15/ 9/2015 18: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.16 35 13.91 480 7 7
2 1850.28 150 5.43 2650 7 7
3 1846.88 30 11.55 2712 6 7
4 1755.12 30 11.83 2597 6 7
5 1501.88 30 12.26 2244 7 7
6 912.12 30 12.99 1499 7 7
7 -0.08 30 14.31 292 7 7
8 -0.08 180 14.30 313 7 21

Cycle 143 GMT 5/ 9/2015 17:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.12 35 13.91 500 7 7
2 1507.88 150 10.04 2242 7 7
3 269.96 30 13.74 684 7 7
4 0.04 30 14.14 334 7 7
5 0.08 180 14.14 344 7 25

Cycle 142 GMT 4/ 9/2015 18:18: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.28 35 13.78 519 7 7
2 1510.80 150 9.94 2239 7 7
3 411.88 30 13.56 869 7 7
4 0.12 31 14.25 311 7 7
5 0.12 181 14.14 346 7 16

Cycle 141 GMT 3/ 9/2015 19: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.80 35 13.97 500 7 7
2 1512.44 150 9.97 2236 7 7
3 301.84 30 13.68 730 7 7
4 0.16 30 14.16 328 7 7
5 0.04 181 14.12 352 7 22

Cycle 140 GMT 2/ 9/2015 19:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.56 34 13.97 500 7 7
2 1964.80 70 4.54 2131 7 7
3 2023.32 20 11.12 2891 6 7
4 1974.16 20 11.60 2903 7 7
5 1879.60 20 11.92 2739 6 7
6 1764.72 20 12.16 2605 6 7
7 1495.00 20 12.45 2283 7 7
8 942.76 21 13.06 1548 7 7
9 245.56 21 13.81 634 7 7
10 0.40 181 14.23 315 7 17

Cycle 139 GMT 28/ 8/2015 10:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.16 35 13.97 500 7 7
2 1963.96 70 4.39 1417 7 8
3 2027.32 20 8.05 2994 6 7
4 1993.32 20 10.48 2898 6 7
5 1916.72 20 11.38 2790 6 7
6 1810.08 20 11.69 2677 6 7
7 1557.96 20 12.22 2357 6 7
8 1284.40 20 12.51 2045 7 7
9 732.00 20 13.25 1295 7 7
10 73.80 21 14.02 411 7 7
11 0.08 21 14.23 300 7 7
12 0.04 180 14.23 304 7 13

Cycle 138 GMT 18/ 8/2015 11:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.88 35 13.97 500 7 7
2 1961.44 70 4.42 1577 7 7
3 2028.04 21 9.02 2907 6 7
4 1989.80 21 10.71 2909 6 7
5 1906.92 21 11.36 2796 6 7
6 1791.12 21 11.79 2629 6 7
7 1519.76 21 12.21 2315 6 7
8 1099.12 21 12.77 1775 7 7
9 393.68 21 13.64 837 7 7
10 0.32 181 14.23 300 7 16

Cycle 137 GMT 8/ 8/2015 11:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 35 13.85 519 7 7
2 1963.08 70 4.46 1714 7 7
3 2022.84 20 9.96 2886 6 7
4 1976.00 20 11.16 2879 6 7
5 1891.24 20 11.62 2768 6 7
6 1780.08 20 11.90 2648 6 7
7 1516.88 21 12.24 2315 7 7
8 1097.16 21 12.79 1777 6 7
9 379.80 21 13.65 822 7 7
10 0.16 180 14.23 305 7 10

Cycle 136 GMT 29/ 7/2015 12:11: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 35 14.10 480 7 7
2 1968.80 70 4.51 1929 7 7
3 2037.24 21 10.45 2918 6 7
4 1976.24 21 11.38 2875 6 7
5 1873.00 21 11.64 2779 6 7
6 1747.28 21 11.98 2617 6 7
7 1333.84 21 12.53 2078 6 7
8 640.12 21 13.35 1162 7 7
9 97.04 21 14.07 444 7 7
10 -0.04 21 14.29 296 7 8
11 -0.00 180 14.23 316 7 11

Cycle 135 GMT 19/ 7/2015 12:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.56 35 13.78 538 7 7
2 1964.72 70 4.59 2340 7 7
3 2006.56 20 11.56 2946 6 7
4 1948.96 20 11.97 2848 6 7
5 1853.72 20 12.08 2766 6 7
6 1739.28 20 12.28 2614 6 7
7 1328.88 20 12.71 2078 7 7
8 788.40 20 13.29 1365 7 7
9 224.24 20 13.91 607 7 7
10 0.04 21 14.23 300 7 7
11 -0.04 180 14.26 315 7 21

Cycle 134 GMT 9/ 7/2015 12:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.56 35 14.10 461 7 7
2 1513.88 70 10.11 2244 7 7
3 1411.08 20 12.50 2167 7 7
4 1283.88 20 12.61 2047 7 7
5 726.36 21 13.19 1326 7 7
6 66.80 21 14.13 414 7 7
7 0.28 21 14.23 343 7 7
8 0.24 180 14.17 350 7 19

Cycle 133 GMT 8/ 7/2015 13:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.84 34 13.97 480 7 7
2 1505.88 70 9.98 2249 7 7
3 1413.24 20 12.50 2155 7 7
4 1282.76 20 12.59 2052 7 7
5 736.20 21 13.20 1324 7 7
6 157.24 21 13.96 540 7 7
7 -0.08 21 14.25 324 7 7
8 -0.16 180 14.14 353 7 17

Cycle 132 GMT 7/ 7/2015 13:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.16 34 14.04 480 7 7
2 1508.04 70 10.01 2243 7 7
3 1405.08 20 12.50 2172 6 7
4 1278.76 21 12.62 2027 7 7
5 711.64 21 13.24 1302 7 7
6 123.00 21 14.01 493 7 7
7 0.12 21 14.16 345 7 7
8 -0.00 180 14.12 357 7 20

Cycle 131 GMT 6/ 7/2015 13:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 34 13.85 500 7 7
2 1962.44 70 4.54 2075 7 7
3 2018.84 20 11.12 2944 6 7
4 1972.44 20 11.65 2905 6 7
5 1876.84 20 12.03 2749 6 7
6 1748.32 20 12.23 2588 6 7
7 1331.76 20 12.64 2085 6 7
8 920.12 21 13.01 1548 7 7
9 209.04 21 13.86 593 7 7
10 0.16 21 14.23 307 7 7
11 0.08 180 14.17 334 7 24

Cycle 130 GMT 1/ 7/2015 5: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.04 35 13.97 500 7 7
2 1961.36 70 4.35 1267 7 8
3 2025.20 20 7.32 2874 6 7
4 2022.52 20 10.57 2881 6 7
5 1948.24 20 11.37 2840 6 7
6 1838.20 20 11.73 2711 6 7
7 1707.36 20 12.03 2559 6 7
8 1297.68 20 12.59 2033 6 7
9 874.20 20 13.08 1489 7 7
10 154.56 20 13.93 523 7 7
11 0.04 21 14.27 304 7 7
12 0.04 180 14.21 313 7 26

Cycle 129 GMT 21/ 6/2015 5:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 34 14.10 480 7 7
2 1961.56 70 4.37 1406 7 8
3 2029.00 20 8.37 2948 6 7
4 2002.36 20 10.94 2920 6 7
5 1927.08 20 11.49 2840 6 7
6 1821.92 20 11.87 2679 6 7
7 1564.52 20 12.31 2369 6 7
8 1152.44 20 12.69 1874 7 7
9 592.68 20 13.47 1090 7 7
10 65.80 20 14.10 393 7 7
11 -0.00 21 14.25 309 7 7
12 0.04 180 14.20 318 7 20

Cycle 128 GMT 11/ 6/2015 5:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 34 13.97 500 7 7
2 1964.64 70 4.42 1632 7 7
3 2040.28 20 9.51 2944 6 7
4 1992.72 20 11.14 2927 6 7
5 1910.20 20 11.61 2819 6 7
6 1797.12 20 11.92 2691 6 7
7 1529.36 20 12.41 2321 6 7
8 1113.56 20 12.87 1802 7 7
9 408.20 20 13.67 857 7 7
10 27.48 20 14.18 331 7 7
11 0.16 21 14.32 296 7 9
12 -0.00 180 14.23 313 7 21

Cycle 127 GMT 1/ 6/2015 6:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.64 34 14.10 480 7 7
2 1960.84 70 4.50 1917 7 7
3 2025.84 20 10.63 2968 6 7
4 1973.52 20 11.61 2886 6 7
5 1877.40 20 11.94 2759 7 7
6 1751.72 20 12.23 2586 7 7
7 1350.76 21 12.52 2117 6 7
8 803.44 21 13.20 1388 7 7
9 116.12 21 14.08 469 7 7
10 -0.12 21 14.32 302 7 7
11 -0.16 180 14.25 313 7 23

Cycle 126 GMT 22/ 5/2015 6:30: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.52 34 14.04 500 7 7
2 1967.08 70 4.62 2450 7 7
3 2023.48 20 11.85 2968 6 7
4 1964.64 20 12.09 2877 6 7
5 1862.04 20 12.21 2778 6 7
6 1733.64 20 12.35 2602 6 7
7 1321.64 20 12.80 2054 6 7
8 908.96 21 13.12 1533 7 7
9 162.48 21 14.02 529 7 7
10 0.32 20 14.34 292 7 7
11 0.20 180 14.27 320 7 17

Cycle 125 GMT 12/ 5/2015 7:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 34 14.04 480 7 7
2 1515.88 70 10.27 2262 7 7
3 1418.60 20 12.57 2191 7 7
4 1287.24 20 12.67 2066 7 7
5 720.48 21 13.25 1320 7 7
6 61.88 21 14.17 412 7 7
7 0.12 20 14.33 333 7 7
8 -0.00 180 14.19 351 7 16

Cycle 124 GMT 11/ 5/2015 7:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.40 34 13.97 500 7 7
2 1502.24 70 10.30 2235 7 7
3 1400.36 20 12.59 2153 7 7
4 1277.76 21 12.65 2033 7 7
5 569.88 21 13.42 1102 7 7
6 29.88 21 14.17 364 7 7
7 -0.00 21 14.32 343 7 7
8 0.08 180 14.18 353 7 21

Cycle 123 GMT 10/ 5/2015 7:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 30 14.10 480 7 7
2 1188.20 4 12.06 1846 7 7
3 1519.64 70 10.47 2271 7 7
4 1417.32 20 12.59 2187 7 7
5 1151.36 21 12.79 1879 7 7
6 593.96 21 13.41 1125 7 7
7 64.40 21 14.13 418 7 7
8 0.04 21 14.30 341 7 7
9 0.04 180 14.17 357 7 20

Cycle 122 GMT 9/ 5/2015 8:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.84 28 13.91 519 7 7
2 1245.56 6 11.88 1961 7 7
3 1961.24 70 4.85 3044 7 7
4 2012.76 20 11.86 2973 7 7
5 1956.64 20 12.11 2838 6 7
6 1861.96 20 12.23 2752 6 7
7 1612.88 20 12.41 2465 6 7
8 1340.96 20 12.73 2083 7 7
9 770.72 21 13.28 1339 7 7
10 93.48 21 14.16 422 7 7
11 0.24 21 14.35 294 7 7
12 0.24 180 14.21 332 7 15

Cycle 121 GMT 3/ 5/2015 23:41: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.84 34 13.97 519 7 7
2 1964.00 20 4.35 1029 7 8
3 2023.12 21 5.49 2552 6 7
4 2066.00 21 10.55 2971 6 7
5 2001.40 21 11.40 2901 6 7
6 1900.92 21 11.71 2775 6 7
7 1783.20 21 11.88 2674 6 7
8 1234.56 21 12.55 1982 7 7
9 806.68 20 13.15 1398 7 7
10 105.52 20 14.08 446 7 7
11 21.52 20 14.29 323 7 7
12 0.12 20 14.36 297 7 7
13 0.08 180 14.19 319 7 21

Cycle 120 GMT 23/ 4/2015 23:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 34 13.91 519 7 7
2 1963.84 20 4.37 1134 7 7
3 2022.16 21 6.04 2837 6 7
4 2055.64 21 11.13 2976 6 7
5 1995.44 21 11.60 2909 6 7
6 1882.60 21 11.83 2781 6 7
7 1755.48 21 12.01 2634 6 7
8 1329.84 20 12.66 2071 7 7
9 750.52 20 13.20 1323 7 7
10 149.76 20 14.04 509 7 7
11 11.48 21 14.30 309 7 7
12 0.20 21 14.34 296 7 7
13 0.20 180 14.18 329 7 37

Cycle 119 GMT 14/ 4/2015 0:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 34 13.97 519 7 7
2 1967.60 20 4.41 1223 7 7
3 2035.16 21 7.46 2939 6 7
4 2008.68 21 11.58 2914 7 7
5 1930.68 21 11.91 2805 6 7
6 1814.72 21 12.04 2691 6 7
7 1548.08 21 12.33 2362 6 7
8 983.80 20 12.99 1629 7 7
9 297.56 20 13.79 713 7 7
10 10.84 21 14.30 307 7 7
11 -0.00 21 14.35 294 7 7
12 0.08 180 14.17 321 7 23

Cycle 118 GMT 4/ 4/2015 0:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.16 34 14.10 480 7 7
2 1963.32 21 4.41 1315 7 7
3 2021.92 20 8.31 2862 6 7
4 1996.44 20 11.66 2917 6 7
5 1912.96 20 11.80 2852 6 7
6 1799.28 20 12.12 2679 6 7
7 1529.76 20 12.45 2321 6 7
8 1116.36 20 12.87 1797 6 7
9 684.56 20 13.31 1239 7 7
10 92.52 20 14.09 434 7 7
11 0.08 21 14.36 294 7 7
12 0.04 180 14.17 318 7 19

Cycle 117 GMT 25/ 3/2015 1:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 33 14.10 500 7 7
2 1060.40 1 11.94 1711 7 7
3 1960.76 21 4.45 1497 7 7
4 2014.12 20 10.01 2889 6 7
5 1986.84 20 11.77 2939 6 7
6 1905.00 20 12.02 2802 6 7
7 1775.44 20 12.15 2662 6 7
8 1507.96 20 12.45 2316 6 7
9 1076.84 20 12.86 1759 7 7
10 245.24 20 13.82 655 7 7
11 45.00 20 14.19 372 7 7
12 0.52 181 14.20 315 7 20

Cycle 116 GMT 15/ 3/2015 1:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.60 34 14.10 480 7 7
2 964.36 -1 14.10 480 7 7
3 1966.00 21 4.44 1419 7 7
4 2030.44 20 9.38 2896 6 7
5 1983.12 20 11.69 2905 6 7
6 1894.88 21 11.83 2805 6 7
7 1768.28 20 12.17 2646 6 7
8 1375.36 20 12.57 2153 6 7
9 961.32 20 13.04 1595 6 7
10 409.00 20 13.63 872 7 7
11 48.32 20 14.25 362 7 7
12 0.16 181 14.19 313 7 22

Cycle 115 GMT 5/ 3/2015 2: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.60 34 14.10 500 7 7
2 1966.52 20 4.41 1255 7 7
3 2025.44 21 7.51 2939 6 7
4 1988.72 21 11.61 2901 6 7
5 1897.68 21 11.88 2785 6 7
6 1798.08 21 12.05 2674 6 7
7 1376.12 21 12.52 2153 6 7
8 1098.76 21 12.76 1792 6 7
9 161.36 21 13.93 552 7 7
10 0.36 21 14.28 309 7 7
11 -0.08 180 14.14 323 7 16

Cycle 114 GMT 23/ 2/2015 2: 6: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 34 13.97 519 7 7
2 1964.56 20 4.41 1200 7 7
3 2011.84 21 7.49 2843 6 7
4 1989.16 21 11.53 2907 6 7
5 1910.12 21 11.87 2798 6 7
6 1793.92 21 12.02 2674 6 7
7 1523.92 21 12.35 2328 6 7
8 955.44 20 13.04 1588 7 7
9 519.64 20 13.47 1021 7 7
10 41.88 21 14.18 369 7 7
11 0.12 181 14.19 315 7 19

Cycle 113 GMT 13/ 2/2015 2:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 34 14.10 442 7 7
2 1962.88 20 4.35 1106 7 8
3 2024.20 21 6.02 2790 6 7
4 2045.84 21 11.28 2939 6 7
5 1963.92 21 11.64 2882 6 7
6 1843.60 21 11.95 2738 6 7
7 1582.20 21 12.34 2375 6 7
8 1159.92 20 12.78 1874 7 7
9 588.60 20 13.43 1110 7 7
10 70.92 21 14.15 403 7 7
11 25.80 181 14.19 321 7 10

Cycle 112 GMT 3/ 2/2015 3: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.92 34 14.23 423 7 7
2 1965.96 20 4.35 1093 7 8
3 2034.12 21 5.74 2670 6 7
4 2071.20 21 10.99 2984 6 7
5 1997.52 21 11.57 2928 6 7
6 1883.76 21 11.82 2809 6 7
7 1756.32 21 12.07 2623 6 7
8 1193.56 21 12.73 1911 6 7
9 499.16 20 13.58 982 7 7
10 94.96 21 14.16 427 7 7
11 91.88 181 14.01 403 7 16

Cycle 111 GMT 24/ 1/2015 3:24: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 34 14.23 423 7 7
2 1965.96 30 4.40 1249 7 7
3 2048.12 26 7.15 2985 6 7
4 2008.92 25 11.41 2955 6 7
5 1876.52 25 11.88 2738 6 7
6 1717.84 25 12.13 2553 6 7
7 1181.28 25 12.71 1886 7 7
8 474.12 25 13.58 949 7 7
9 24.52 25 14.28 334 7 7
10 8.12 181 14.23 304 7 9

Cycle 110 GMT 14/ 1/2015 3:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.44 34 14.23 423 7 7
2 1965.08 30 4.40 1285 7 7
3 2036.44 26 8.24 2892 6 7
4 1976.96 25 11.61 2884 6 7
5 1856.48 25 11.86 2743 6 7
6 1533.80 25 12.29 2351 6 7
7 1027.76 25 12.90 1690 7 7
8 326.00 25 13.79 749 7 7
9 22.76 25 14.24 335 7 7
10 18.80 181 14.21 304 7 9

Cycle 109 GMT 4/ 1/2015 4: 4: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.04 34 14.17 442 7 7
2 1962.20 30 4.41 1276 7 7
3 2038.36 26 9.05 2847 6 7
4 1962.80 25 11.65 2901 6 7
5 1841.76 25 11.96 2730 6 7
6 1522.28 25 12.32 2340 6 7
7 1006.28 25 12.91 1668 7 7
8 278.52 25 13.85 678 7 7
9 19.52 25 14.28 324 7 7
10 0.12 25 14.38 299 7 7
11 0.16 181 14.24 302 7 28

Cycle 108 GMT 25/12/2014 4:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.00 34 14.17 442 7 7
2 1964.92 20 4.41 1217 7 7
3 2031.88 21 7.82 2882 6 7
4 2007.40 21 11.64 2965 6 7
5 1920.60 21 11.96 2830 6 7
6 1804.20 21 12.12 2694 7 7
7 1410.60 21 12.57 2185 6 7
8 981.80 21 13.05 1612 7 7
9 254.00 20 13.95 650 7 7
10 0.08 181 14.26 300 7 8

Cycle 107 GMT 15/12/2014 4:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.76 34 14.23 423 7 7
2 1972.28 20 4.41 1206 7 7
3 2053.96 21 7.20 2967 6 7
4 2033.12 21 11.49 3023 6 7
5 1932.52 21 11.95 2826 6 7
6 1818.36 21 12.06 2717 6 7
7 1425.40 21 12.51 2217 6 7
8 883.52 20 13.16 1499 7 7
9 309.36 20 13.81 744 7 7
10 26.44 181 14.20 317 7 15

Cycle 106 GMT 5/12/2014 5: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.80 34 14.17 423 7 7
2 2001.32 30 4.43 1452 7 7
3 2048.32 20 9.73 2973 6 7
4 2014.44 20 11.77 2956 6 7
5 1952.00 21 11.92 2860 6 7
6 1862.12 20 12.21 2742 6 7
7 1552.28 20 12.53 2374 6 7
8 1008.08 20 13.00 1684 7 7
9 368.84 20 13.80 807 7 7
10 0.16 20 14.30 299 7 7
11 0.12 200 14.24 294 7 18

Cycle 105 GMT 25/11/2014 5:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 34 14.23 423 7 7
2 2007.12 31 4.50 1815 7 7
3 2045.00 20 11.34 3009 6 7
4 1994.40 20 11.95 2898 6 7
5 1926.00 20 12.12 2831 6 7
6 1830.36 20 12.27 2713 6 7
7 1207.52 20 12.88 1925 6 7
8 993.68 20 13.09 1646 6 7
9 325.72 20 13.85 742 7 7
10 0.36 201 14.24 296 7 12

Cycle 104 GMT 15/11/2014 6: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.28 33 14.10 500 7 7
2 1040.16 1 11.81 1711 7 7
3 2004.36 31 4.61 2218 7 7
4 2039.76 20 11.74 2985 6 7
5 1991.00 20 12.05 2927 6 7
6 1913.08 20 12.18 2821 6 7
7 1815.72 20 12.31 2682 6 7
8 1303.72 20 12.72 2076 6 7
9 882.72 20 13.20 1499 7 7
10 147.52 21 14.13 504 7 7
11 24.84 21 14.32 330 7 7
12 -0.04 21 14.36 300 7 7
13 -0.08 200 14.19 334 7 55

Cycle 103 GMT 5/11/2014 6:22: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 33 14.17 480 7 7
2 2007.28 31 6.15 2662 7 7
3 2030.44 20 11.83 2953 6 7
4 1971.48 20 12.04 2886 6 7
5 1878.12 20 12.15 2792 6 7
6 1674.64 20 12.44 2514 6 7
7 1240.96 20 12.83 1963 6 7
8 801.52 20 13.24 1391 7 7
9 131.36 21 14.07 493 7 7
10 18.20 21 14.29 334 7 7
11 -0.04 201 14.15 331 7 24

Cycle 102 GMT 26/10/2014 7: 7:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.80 32 14.10 500 7 7
2 2006.00 31 6.93 2634 7 7
3 1981.48 20 11.87 2886 6 7
4 1913.64 20 12.15 2792 6 7
5 1823.60 20 12.26 2677 6 7
6 1624.96 20 12.50 2439 6 7
7 897.24 20 13.08 1533 7 7
8 696.80 21 13.28 1264 7 7
9 44.32 21 14.19 379 7 7
10 -0.00 21 14.30 315 7 7
11 0.16 200 14.06 346 7 42

Cycle 101 GMT 16/10/2014 7:59: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.04 32 14.04 519 7 7
2 2005.52 31 7.25 2698 7 7
3 1976.00 20 11.95 2869 6 7
4 1901.76 20 12.11 2788 6 7
5 1804.76 20 12.21 2689 6 7
6 1484.52 20 12.57 2268 6 7
7 940.84 20 13.07 1573 6 7
8 398.60 20 13.65 877 7 7
9 13.80 20 14.19 343 7 7
10 2.52 20 14.15 328 7 7
11 0.12 20 14.22 321 7 7
12 0.08 200 13.96 355 9 54

Cycle 100 GMT 6/10/2014 8:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.24 32 13.78 557 7 7
2 2001.68 31 7.58 2823 7 7
3 1969.80 20 11.94 2872 6 7
4 1903.12 20 12.16 2771 6 7
5 1805.88 20 12.29 2660 6 7
6 1383.76 20 12.69 2143 6 7
7 956.88 20 12.96 1629 6 7
8 625.52 21 13.32 1174 7 7
9 23.40 21 14.16 362 7 7
10 -0.04 21 14.15 332 7 7
11 -0.00 200 13.83 366 7 32

Cycle 99 GMT 26/ 9/2014 9:14: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.12 32 13.97 519 7 7
2 2006.44 31 7.86 2719 7 7
3 1977.36 20 11.94 2865 6 6
4 1907.24 20 12.06 2805 6 7
5 1812.48 20 12.23 2675 6 7
6 1397.64 20 12.66 2155 6 7
7 762.64 20 13.17 1372 6 7
8 244.60 21 13.71 676 7 7
9 0.12 201 13.87 360 7 18

Cycle 98 GMT 16/ 9/2014 9:55: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.28 32 13.97 519 7 7
2 2004.88 31 8.14 2795 7 7
3 1969.12 20 11.97 2896 6 7
4 1896.00 20 12.15 2763 6 7
5 1800.08 20 12.24 2667 6 7
6 1375.20 20 12.68 2091 6 7
7 835.52 20 13.12 1432 6 7
8 498.24 21 13.44 1006 7 7
9 0.16 201 13.89 356 7 20

Cycle 97 GMT 6/ 9/2014 10:48: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 32 13.97 519 7 7
2 2002.36 31 8.50 2832 7 7
3 1958.76 20 11.96 2879 6 7
4 1888.36 20 12.16 2771 6 7
5 1799.68 20 12.25 2655 6 7
6 1278.44 20 12.73 2016 6 7
7 741.16 20 13.27 1283 7 7
8 301.84 21 13.69 747 7 7
9 0.28 21 14.16 332 7 7
10 0.16 200 13.85 361 7 19

Cycle 96 GMT 27/ 8/2014 11:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.52 31 14.04 500 7 7
2 2006.32 31 8.62 2778 7 7
3 1972.04 20 11.92 2905 6 7
4 1889.08 20 12.08 2805 6 7
5 1685.28 20 12.30 2559 6 7
6 1185.24 20 12.79 1925 6 7
7 982.72 20 12.99 1643 7 7
8 214.20 21 13.81 642 7 7
9 -0.08 21 14.22 332 7 7
10 -0.08 200 13.88 351 7 16

Cycle 95 GMT 17/ 8/2014 12: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 31 14.04 519 7 7
2 2003.96 31 9.00 2797 7 7
3 1953.44 20 11.92 2893 6 7
4 1879.76 20 12.10 2795 6 7
5 1786.08 20 12.23 2653 6 7
6 1362.36 20 12.64 2112 6 7
7 920.48 20 13.02 1566 6 7
8 268.40 21 13.78 700 7 7
9 0.04 201 14.01 347 7 19

Cycle 94 GMT 7/ 8/2014 12:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.28 33 13.91 519 7 7
2 964.12 -1 13.91 519 7 7
3 2007.00 31 8.36 2794 7 7
4 1967.08 20 11.96 2874 6 7
5 1896.00 20 12.05 2809 6 7
6 1804.08 20 12.18 2677 6 7
7 1172.04 20 12.80 1884 6 7
8 646.52 20 13.28 1218 6 7
9 219.88 21 13.79 646 7 7
10 -0.04 21 14.23 328 7 7
11 -0.12 200 13.88 359 7 34

Cycle 93 GMT 28/ 7/2014 13:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.80 33 14.10 480 7 7
2 1491.20 31 9.47 2202 7 7
3 1490.64 20 12.35 2292 6 7
4 1430.72 20 12.49 2218 6 7
5 1345.80 20 12.59 2114 6 7
6 1040.80 20 12.89 1725 6 7
7 411.52 20 13.64 889 7 7
8 37.24 20 14.17 365 7 7
9 0.32 21 14.28 317 7 7
10 0.32 200 14.03 348 7 33

Cycle 92 GMT 18/ 7/2014 13:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 32 14.10 500 7 7
2 2002.16 31 8.64 2726 7 7
3 1955.44 20 12.02 2838 6 7
4 1879.80 20 12.07 2807 6 7
5 1782.12 20 12.20 2665 6 7
6 1267.00 20 12.72 2021 6 7
7 835.88 20 13.14 1456 7 7
8 187.92 20 14.02 564 7 7
9 9.60 20 14.33 319 7 7
10 0.04 21 14.34 304 7 7
11 -0.20 200 14.06 348 7 34

Cycle 91 GMT 8/ 7/2014 14:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 32 13.97 519 7 7
2 2004.20 31 8.99 2736 7 7
3 1959.44 20 11.99 2872 6 7
4 1884.24 20 12.08 2797 6 7
5 1787.52 20 12.21 2677 6 7
6 1363.60 20 12.62 2148 6 7
7 826.52 20 13.22 1427 7 7
8 280.76 20 13.92 689 7 7
9 0.32 21 14.29 313 7 7
10 0.12 200 14.13 338 7 23

Cycle 90 GMT 28/ 6/2014 15: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 33 14.10 500 7 7
2 965.60 -1 14.10 500 7 7
3 2001.36 31 8.33 2706 7 7
4 1957.32 21 11.84 2873 6 7
5 1876.20 20 12.06 2790 6 7
6 1777.44 21 12.15 2655 6 7
7 1155.36 20 12.79 1876 6 7
8 736.16 20 13.31 1307 7 7
9 108.84 20 14.08 475 7 7
10 0.28 21 14.34 315 7 7
11 0.24 200 14.12 336 7 34

Cycle 89 GMT 18/ 6/2014 15:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.68 33 14.17 480 7 7
2 1740.80 31 8.67 2406 7 7
3 1734.28 20 12.15 2588 6 7
4 1670.24 20 12.26 2523 6 7
5 1579.64 20 12.38 2403 6 7
6 1177.20 20 12.76 1913 6 7
7 860.20 20 13.10 1492 7 7
8 100.40 20 14.18 442 7 7
9 46.52 20 14.28 372 7 7
10 -0.00 21 14.37 304 7 7
11 0.08 200 14.13 340 7 38

Cycle 88 GMT 8/ 6/2014 15:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.08 33 14.17 500 7 7
2 1832.88 31 8.27 2519 7 7
3 1811.24 20 12.00 2720 6 7
4 1743.44 20 12.18 2607 6 7
5 1647.20 20 12.30 2504 6 7
6 1341.88 20 12.67 2088 6 6
7 816.76 20 13.20 1412 7 7
8 173.96 20 14.06 552 7 7
9 38.72 20 14.27 362 7 7
10 0.12 201 14.14 341 7 33

Cycle 87 GMT 29/ 5/2014 15: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.60 33 14.10 500 7 7
2 1775.32 31 8.17 2308 7 7
3 1774.64 20 12.00 2641 6 7
4 1713.48 20 12.13 2593 6 7
5 1623.80 21 12.23 2454 6 7
6 1225.96 20 12.75 1961 6 7
7 915.28 20 13.07 1559 7 7
8 244.20 20 13.98 638 7 7
9 25.00 20 14.36 331 7 7
10 -0.04 21 14.41 298 7 7
11 -0.04 200 14.14 341 7 37

Cycle 86 GMT 19/ 5/2014 14:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.76 33 14.23 461 7 7
2 1724.20 31 8.25 2281 7 7
3 1724.08 21 12.02 2574 6 7
4 1661.04 20 12.26 2509 6 7
5 1574.64 20 12.35 2413 6 7
6 1178.44 20 12.80 1893 6 7
7 769.52 20 13.25 1355 7 7
8 139.20 20 14.07 499 7 7
9 11.92 20 14.41 299 7 7
10 0.24 21 14.37 296 7 7
11 0.20 200 14.16 332 7 26

Cycle 85 GMT 9/ 5/2014 14:47: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 33 14.23 480 7 7
2 1840.88 31 8.09 2500 7 7
3 1822.48 21 11.93 2734 6 7
4 1749.28 20 12.19 2626 6 7
5 1656.64 21 12.25 2499 6 7
6 1340.24 20 12.65 2107 6 7
7 800.24 20 13.21 1400 7 7
8 154.08 20 14.05 530 7 7
9 32.00 20 14.32 343 7 7
10 0.08 21 14.40 296 7 7
11 0.08 200 14.17 331 7 35

Cycle 84 GMT 29/ 4/2014 14:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.84 33 14.17 480 7 7
2 2006.76 31 8.25 2596 7 7
3 1966.20 20 11.96 2888 6 7
4 1888.44 20 12.04 2814 6 7
5 1683.04 20 12.37 2526 6 7
6 1176.48 20 12.82 1893 6 7
7 764.52 20 13.28 1350 7 7
8 224.16 20 13.96 624 7 7
9 58.56 20 14.31 384 7 7
10 0.08 21 14.43 288 7 7
11 -0.00 200 14.18 337 7 32

Cycle 83 GMT 19/ 4/2014 15: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.32 33 14.23 480 7 7
2 2000.52 31 8.67 2587 7 7
3 1954.32 20 11.96 2860 6 7
4 1874.08 20 12.16 2756 6 7
5 1676.80 20 12.39 2526 6 7
6 1369.36 20 12.67 2143 6 7
7 943.32 20 13.05 1602 7 7
8 276.32 20 13.90 689 7 7
9 67.20 20 14.27 398 7 7
10 0.08 21 14.42 296 7 7
11 -0.04 200 14.15 336 7 27

Cycle 82 GMT 9/ 4/2014 15:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.88 33 14.17 480 7 7
2 2005.32 31 9.01 2762 7 7
3 1952.12 20 11.93 2879 6 7
4 1880.28 20 12.15 2764 6 7
5 1791.68 20 12.29 2648 6 7
6 1368.64 20 12.67 2141 6 7
7 931.44 20 13.12 1540 7 7
8 176.92 20 14.04 559 7 7
9 45.68 20 14.34 362 7 7
10 0.20 21 14.42 302 7 7
11 0.20 200 14.18 332 7 36

Cycle 81 GMT 30/ 3/2014 16:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.72 33 14.23 480 7 7
2 1806.52 31 9.37 2470 7 7
3 1775.72 21 12.01 2664 6 7
4 1699.76 20 12.30 2540 6 7
5 1602.84 21 12.34 2437 6 7
6 1173.68 20 12.84 1889 6 7
7 644.28 20 13.39 1191 7 7
8 95.88 20 14.15 446 7 7
9 43.92 20 14.31 367 7 7
10 0.12 201 14.13 346 7 23

Cycle 80 GMT 20/ 3/2014 16:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.48 33 14.23 480 7 7
2 1618.96 31 9.50 2343 7 7
3 1619.08 20 12.20 2463 6 7
4 1575.60 20 12.40 2391 6 7
5 1483.12 20 12.53 2259 6 7
6 1064.20 20 12.94 1742 6 7
7 540.60 20 13.57 1033 7 7
8 95.92 20 14.12 453 7 7
9 22.40 20 14.30 338 7 7
10 0.16 21 14.38 313 7 7
11 -0.08 200 14.07 356 7 41

Cycle 79 GMT 10/ 3/2014 16:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.64 33 14.23 461 7 7
2 1551.48 31 9.88 2225 7 7
3 1551.72 20 12.28 2362 6 7
4 1491.56 20 12.45 2288 6 7
5 1401.24 20 12.57 2182 6 7
6 888.52 20 13.10 1523 7 7
7 479.08 20 13.60 977 7 7
8 64.04 20 14.16 415 7 7
9 29.28 20 14.28 353 7 7
10 -0.00 21 14.35 313 7 7
11 -0.00 200 14.08 355 7 64

Cycle 78 GMT 28/ 2/2014 16:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.76 33 14.23 480 7 7
2 1657.44 31 9.49 2346 7 7
3 1648.84 20 12.23 2478 6 7
4 1583.20 20 12.41 2410 6 7
5 1485.28 20 12.58 2261 6 7
6 1066.44 20 12.97 1747 6 7
7 551.64 20 13.51 1069 7 7
8 67.52 20 14.23 398 7 7
9 31.36 20 14.36 346 7 7
10 -0.00 21 14.42 300 7 7
11 -0.00 200 14.14 338 7 49

Cycle 77 GMT 18/ 2/2014 16:51: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 33 14.23 480 7 7
2 1950.60 31 8.99 2625 7 7
3 1905.68 20 12.03 2807 6 7
4 1831.32 20 12.21 2713 6 7
5 1739.36 21 12.24 2617 6 7
6 1312.16 20 12.67 2093 6 7
7 767.36 20 13.31 1355 7 7
8 127.08 20 14.13 492 7 7
9 60.40 20 14.27 391 7 7
10 0.12 21 14.41 302 7 7
11 0.12 200 14.14 346 7 34

Cycle 76 GMT 8/ 2/2014 16: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.24 33 14.23 480 7 7
2 2002.96 31 9.01 2736 7 7
3 1955.08 20 11.96 2864 6 7
4 1873.04 20 12.22 2749 6 7
5 1774.72 20 12.32 2631 6 7
6 1240.16 20 12.79 1985 6 7
7 723.08 20 13.37 1283 7 7
8 188.20 20 14.05 566 7 7
9 42.84 20 14.33 357 7 7
10 0.12 20 14.46 302 7 7
11 0.08 200 14.17 339 7 25

Cycle 75 GMT 29/ 1/2014 16:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.08 33 14.23 480 7 7
2 2003.76 31 8.88 2709 7 7
3 1957.96 20 12.00 2869 6 7
4 1879.92 20 12.10 2807 6 7
5 1688.76 20 12.43 2547 6 7
6 1363.88 20 12.72 2141 6 7
7 827.08 20 13.22 1430 7 7
8 161.92 20 14.09 533 7 7
9 35.60 20 14.32 353 7 7
10 -0.00 21 14.38 300 7 7
11 -0.04 200 14.15 330 7 40

Cycle 74 GMT 19/ 1/2014 17:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.88 33 14.23 480 7 7
2 2008.20 31 9.07 2697 7 7
3 1965.08 20 11.91 2913 6 7
4 1882.44 20 12.11 2807 6 7
5 1592.68 20 12.47 2446 6 7
6 1284.52 20 12.77 2040 6 7
7 655.92 20 13.48 1184 7 7
8 226.00 20 14.04 605 7 7
9 28.84 20 14.34 340 7 7
10 0.16 20 14.41 295 7 7
11 0.08 200 14.13 351 7 43

Cycle 73 GMT 9/ 1/2014 18:19: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.40 33 14.23 480 7 7
2 2003.64 31 9.27 2736 7 7
3 1955.52 20 11.99 2881 6 7
4 1877.44 20 12.19 2788 6 7
5 1587.32 20 12.57 2391 6 7
6 1185.00 20 12.90 1893 6 7
7 762.76 20 13.31 1357 7 7
8 108.68 20 14.15 463 7 7
9 25.20 20 14.35 340 7 7
10 -0.00 21 14.39 309 7 7
11 -0.00 200 14.11 355 7 35

Cycle 72 GMT 30/12/2013 18:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 33 14.17 500 7 7
2 2003.72 31 9.35 2757 7 7
3 1954.40 20 12.05 2877 6 7
4 1876.28 20 12.22 2778 6 7
5 1583.32 20 12.50 2425 6 7
6 1182.96 20 12.90 1886 6 7
7 759.44 20 13.31 1343 7 7
8 196.88 20 14.06 576 7 7
9 1.20 21 14.39 311 7 7
10 0.08 201 14.08 347 7 18

Cycle 71 GMT 20/12/2013 19:35:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.80 33 14.10 519 7 7
2 2005.32 31 9.29 2768 7 7
3 1955.40 20 11.98 2881 6 7
4 1877.76 20 12.20 2773 6 7
5 1574.16 20 12.50 2415 6 7
6 1167.16 20 12.88 1898 6 7
7 743.52 20 13.34 1326 7 7
8 81.40 20 14.19 425 7 7
9 0.16 201 14.10 342 7 16

Cycle 70 GMT 10/12/2013 20:24: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.48 33 14.23 480 7 7
2 2005.36 31 8.97 2690 7 7
3 1962.20 21 11.93 2884 6 7
4 1881.44 20 12.18 2807 6 7
5 1684.80 20 12.46 2543 6 7
6 1286.28 20 12.79 2038 6 7
7 838.64 20 13.23 1458 7 7
8 374.56 20 13.83 816 7 7
9 0.84 201 14.08 343 7 21

Cycle 69 GMT 30/11/2013 21:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.28 33 14.10 519 7 7
2 2003.64 31 8.55 2662 7 7
3 1960.12 20 11.96 2903 6 7
4 1884.76 21 12.09 2798 6 7
5 1689.16 20 12.45 2552 6 7
6 1286.32 20 12.75 2062 6 7
7 857.56 20 13.27 1475 7 7
8 104.04 20 14.20 453 7 7
9 0.12 21 14.39 311 7 7
10 0.16 200 14.11 339 7 16

Cycle 68 GMT 20/11/2013 22: 6:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.44 33 14.17 519 7 7
2 2005.60 31 8.91 2719 7 7
3 1965.64 20 11.98 2888 6 7
4 1887.76 20 12.19 2800 6 7
5 1593.84 20 12.57 2412 6 7
6 1184.04 20 12.93 1893 6 7
7 762.84 20 13.36 1350 7 7
8 109.88 20 14.22 449 7 7
9 19.16 20 14.35 331 7 7
10 -0.04 21 14.47 292 7 7
11 0.04 200 14.11 345 7 43

Cycle 67 GMT 10/11/2013 22:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.96 33 14.23 480 7 7
2 2006.40 31 8.52 2725 7 7
3 1962.32 21 11.91 2881 6 7
4 1887.04 21 12.09 2820 6 7
5 1593.12 20 12.49 2446 6 7
6 1189.24 20 12.91 1917 6 7
7 878.80 20 13.24 1506 7 7
8 104.08 20 14.19 449 7 7
9 0.08 21 14.39 304 7 7
10 0.08 200 14.08 343 7 26

Cycle 66 GMT 31/10/2013 23:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.36 33 14.23 500 7 7
2 2004.60 31 9.02 2704 7 7
3 1961.28 20 11.96 2925 6 7
4 1882.52 20 12.20 2816 6 7
5 1783.52 20 12.45 2631 6 7
6 1261.12 20 12.87 2006 6 7
7 838.64 20 13.31 1446 7 7
8 187.64 20 14.11 557 7 7
9 0.20 21 14.41 304 7 7
10 0.08 200 14.08 346 7 27

Cycle 65 GMT 22/10/2013 0:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.80 33 14.17 519 7 7
2 2005.64 31 8.88 2722 7 7
3 1959.48 20 12.06 2881 6 7
4 1885.16 20 12.23 2785 6 7
5 1789.76 20 12.38 2687 6 7
6 1363.12 20 12.82 2114 6 7
7 725.68 20 13.43 1285 7 7
8 91.68 20 14.22 432 7 7
9 -0.00 21 14.42 307 7 7
10 -0.08 200 14.07 347 7 25

Cycle 64 GMT 12/10/2013 1: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.36 33 14.17 519 7 7
2 2000.84 31 8.61 2753 7 7
3 1971.04 20 12.11 2876 6 7
4 1904.96 20 12.20 2831 6 7
5 1707.88 20 12.52 2566 6 7
6 1305.04 20 12.80 2066 7 7
7 877.00 20 13.26 1499 7 7
8 216.76 20 14.07 593 7 7
9 4.00 20 14.41 307 7 7
10 0.04 20 14.42 299 7 7
11 -0.20 200 14.05 354 7 35

Cycle 63 GMT 2/10/2013 1:48:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.08 33 14.23 500 7 7
2 2001.60 31 8.59 2760 7 7
3 1953.20 20 12.12 2869 6 7
4 1879.36 20 12.27 2773 6 7
5 1781.16 20 12.36 2684 6 7
6 1354.76 20 12.82 2121 6 7
7 921.36 20 13.20 1562 7 7
8 355.40 20 13.85 802 7 7
9 0.44 200 14.09 342 7 18

Cycle 62 GMT 22/ 9/2013 2:42: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 33 14.17 538 7 7
2 2003.92 31 9.00 2769 7 7
3 1958.20 20 12.12 2862 6 7
4 1882.12 20 12.28 2788 6 7
5 1783.40 20 12.43 2670 6 7
6 1348.84 20 12.79 2131 6 7
7 906.12 20 13.24 1533 7 7
8 237.08 20 14.05 629 7 7
9 0.20 21 14.42 304 7 7
10 0.08 200 14.05 346 7 34

Cycle 61 GMT 12/ 9/2013 3:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.40 33 14.23 519 7 7
2 2002.68 31 8.71 2884 7 7
3 1956.76 20 12.14 2855 6 7
4 1890.24 20 12.24 2838 6 7
5 1803.56 20 12.41 2711 6 7
6 1284.40 20 12.89 2023 6 7
7 762.24 20 13.38 1352 7 7
8 216.44 20 14.06 603 7 7
9 50.32 20 14.31 372 7 7
10 0.12 21 14.44 302 7 7
11 0.04 200 14.07 353 7 44

Cycle 60 GMT 2/ 9/2013 4:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.16 33 14.04 538 7 7
2 2004.92 31 8.59 2829 7 7
3 1961.92 20 12.07 2886 6 7
4 1881.44 20 12.35 2761 6 7
5 1688.12 20 12.52 2557 6 7
6 1281.72 20 12.92 2014 6 7
7 751.80 20 13.43 1323 7 7
8 125.44 20 14.15 485 7 7
9 0.08 201 14.15 331 7 12

Cycle 59 GMT 23/ 8/2013 5:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.20 33 14.10 519 7 7
2 2003.52 31 8.94 2864 7 7
3 1958.00 20 12.12 2891 6 7
4 1883.88 20 12.35 2768 6 7
5 1688.84 20 12.61 2533 6 7
6 1378.36 20 12.84 2155 6 7
7 645.96 20 13.55 1184 7 7
8 215.20 20 14.05 605 7 7
9 0.24 21 14.43 304 7 7
10 0.24 200 14.08 337 7 35

Cycle 58 GMT 13/ 8/2013 6: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.56 33 14.17 538 7 7
2 2003.68 31 8.99 2914 7 7
3 1950.16 20 12.11 2889 6 7
4 1864.28 20 12.30 2761 6 7
5 1768.72 20 12.45 2653 6 7
6 1353.00 20 12.87 2105 6 7
7 709.60 20 13.48 1278 7 7
8 84.52 20 14.28 415 7 7
9 -0.12 21 14.42 307 7 7
10 -0.16 200 14.06 354 7 23

Cycle 57 GMT 3/ 8/2013 6:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.16 33 14.23 500 7 7
2 2009.20 31 9.15 2854 7 7
3 1965.52 20 12.11 2898 6 7
4 1885.80 20 12.32 2783 6 7
5 1688.12 20 12.60 2523 6 7
6 1275.80 20 12.93 2011 6 7
7 643.32 20 13.55 1180 7 7
8 208.68 20 14.09 593 7 7
9 0.20 21 14.46 307 7 7
10 0.20 200 14.07 353 7 20

Cycle 56 GMT 24/ 7/2013 7:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.00 33 14.29 500 7 7
2 2009.56 31 9.26 2858 7 7
3 1966.00 20 12.17 2874 6 7
4 1885.56 20 12.33 2787 6 7
5 1695.88 20 12.57 2547 6 7
6 1275.40 20 12.90 2031 6 7
7 841.48 20 13.34 1451 7 7
8 76.48 20 14.31 410 7 7
9 0.12 21 14.44 311 7 7
10 0.08 200 14.06 350 7 30

Cycle 55 GMT 14/ 7/2013 8:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.16 33 14.10 538 7 7
2 2001.60 31 9.27 2872 7 7
3 1945.52 20 12.16 2876 6 7
4 1873.28 20 12.37 2752 6 7
5 1784.96 20 12.48 2651 6 7
6 1245.96 20 12.93 1987 6 7
7 816.48 20 13.38 1412 7 7
8 78.84 20 14.27 415 7 7
9 0.12 21 14.45 302 7 7
10 0.16 200 14.08 350 7 26

Cycle 54 GMT 4/ 7/2013 9:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.00 33 14.29 500 7 7
2 2007.72 31 9.42 2860 7 7
3 1947.28 20 12.17 2874 6 7
4 1857.96 20 12.37 2759 6 7
5 1660.72 20 12.65 2482 6 7
6 1341.04 20 12.87 2107 6 7
7 797.04 20 13.42 1386 7 7
8 136.68 20 14.18 504 7 7
9 0.28 21 14.46 307 7 7
10 0.20 200 14.06 358 7 32

Cycle 53 GMT 24/ 6/2013 10:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.24 33 14.10 538 7 7
2 2005.00 31 9.70 2855 7 7
3 1960.52 20 12.18 2864 6 7
4 1879.12 20 12.35 2783 6 7
5 1680.68 20 12.64 2521 6 7
6 1260.88 20 12.97 1999 6 7
7 716.80 20 13.54 1276 7 7
8 63.76 20 14.34 388 7 7
9 0.16 21 14.47 309 7 7
10 0.20 200 14.09 354 7 21

Cycle 52 GMT 14/ 6/2013 11:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.40 33 14.23 519 7 7
2 2002.48 31 9.93 2824 7 7
3 1952.20 20 12.19 2862 6 7
4 1863.52 20 12.37 2742 6 7
5 1665.68 20 12.64 2519 6 7
6 1138.84 20 13.09 1831 6 7
7 513.72 20 13.77 1007 7 7
8 16.96 20 14.38 328 7 7
9 0.36 201 14.07 353 7 21

Cycle 51 GMT 4/ 6/2013 12:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.32 33 14.29 519 7 7
2 2007.44 31 9.70 2929 7 7
3 1960.12 20 12.23 2865 6 7
4 1880.44 20 12.40 2764 6 7
5 1677.08 20 12.64 2533 6 7
6 1153.48 20 13.07 1869 6 7
7 641.64 20 13.59 1191 7 7
8 40.76 20 14.36 357 7 7
9 20.84 20 14.35 335 7 7
10 8.96 20 14.34 316 7 7
11 0.08 21 14.35 337 7 7
12 -0.04 201 14.00 374 7 158

Cycle 50 GMT 25/ 5/2013 13:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.48 33 14.29 500 7 7
2 2001.72 31 10.18 2906 7 7
3 1937.88 20 12.23 2879 6 7
4 1858.28 20 12.37 2780 6 7
5 1764.68 20 12.56 2643 6 7
6 1218.80 20 13.06 1944 6 7
7 581.68 20 13.70 1100 7 7
8 60.24 20 14.32 391 7 7
9 0.08 21 14.48 309 7 7
10 0.08 200 14.09 359 7 28

Cycle 49 GMT 15/ 5/2013 14:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 33 14.29 519 7 7
2 2002.60 31 10.34 2862 7 7
3 1940.84 20 12.23 2876 6 7
4 1855.28 20 12.37 2776 6 7
5 1648.88 20 12.61 2542 6 7
6 1215.28 20 13.05 1954 6 7
7 465.20 20 13.81 951 7 7
8 54.24 20 14.32 393 7 7
9 -0.00 201 14.11 354 7 16

Cycle 48 GMT 5/ 5/2013 15: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.04 33 14.29 519 7 7
2 2004.44 31 10.52 2881 7 7
3 1942.36 21 12.25 2841 6 7
4 1857.48 21 12.40 2745 6 7
5 1759.12 21 12.52 2649 6 7
6 887.32 20 13.37 1528 7 7
7 459.28 20 13.85 949 7 7
8 20.56 20 14.43 336 7 7
9 -0.08 21 14.47 311 7 7
10 -0.04 200 14.06 366 7 29

Cycle 47 GMT 25/ 4/2013 16: 7: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 32 14.36 519 7 7
2 2004.16 31 10.75 2896 7 7
3 1945.44 20 12.39 2835 6 7
4 1852.72 20 12.54 2728 6 7
5 1546.08 20 12.82 2386 6 7
6 1027.28 20 13.29 1708 6 7
7 601.44 20 13.68 1146 7 7
8 54.64 20 14.38 384 7 7
9 0.12 21 14.52 304 7 7
10 0.12 200 14.09 372 7 29

Cycle 46 GMT 15/ 4/2013 16:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.12 32 14.36 519 7 7
2 2002.60 31 10.87 2927 7 7
3 1934.48 20 12.36 2864 6 7
4 1838.96 20 12.57 2740 6 7
5 1626.84 20 12.83 2470 6 7
6 1193.84 20 13.16 1920 6 7
7 529.64 20 13.78 1045 7 7
8 31.64 20 14.41 357 7 7
9 0.08 21 14.48 302 7 7
10 -0.00 200 14.09 364 7 31

Cycle 45 GMT 5/ 4/2013 18: 3: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.60 32 14.42 500 7 7
2 2004.28 31 10.93 2956 7 7
3 1932.16 20 12.38 2872 6 7
4 1847.72 20 12.60 2742 6 7
5 1451.64 20 12.96 2261 6 7
6 1242.64 20 13.16 1994 6 7
7 455.08 20 13.89 944 7 7
8 44.32 20 14.41 374 7 7
9 -0.04 21 14.44 315 7 7
10 0.04 200 14.07 374 7 37

Cycle 44 GMT 26/ 3/2013 19: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.64 32 14.36 519 7 7
2 2001.76 31 10.96 3019 7 7
3 1933.32 20 12.48 2860 6 7
4 1836.88 20 12.62 2728 6 7
5 1435.40 20 13.03 2223 6 7
6 1012.68 20 13.37 1687 7 7
7 356.52 20 14.03 807 7 7
8 7.68 20 14.48 311 7 7
9 0.24 20 14.43 311 7 7
10 0.04 200 14.09 365 7 41

Cycle 43 GMT 16/ 3/2013 19:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.04 32 14.42 500 7 7
2 2003.00 31 11.58 2910 7 7
3 1934.28 20 12.53 2891 6 7
4 1848.92 20 12.67 2754 6 7
5 1545.68 20 13.02 2364 6 7
6 1011.04 20 13.39 1701 6 7
7 272.32 20 14.15 694 7 7
8 29.52 20 14.46 348 7 7
9 0.04 21 14.49 307 7 7
10 0.04 200 14.13 363 7 30

Cycle 42 GMT 6/ 3/2013 20:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.92 32 14.29 538 7 7
2 2006.72 31 11.78 2940 7 7
3 1945.96 20 12.59 2872 6 7
4 1855.88 20 12.72 2759 6 7
5 1533.88 20 13.03 2374 6 7
6 986.44 20 13.44 1660 7 7
7 439.76 20 14.01 908 7 7
8 33.12 20 14.44 365 7 7
9 0.12 21 14.53 307 7 7
10 0.12 200 14.14 365 7 36

Cycle 41 GMT 24/ 2/2013 21:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.24 32 14.42 500 7 7
2 2007.08 49 11.73 2923 7 7
3 1805.44 25 12.67 2726 6 7
4 1356.04 25 13.11 2118 6 7
5 646.36 25 13.76 1195 7 7
6 59.44 25 14.45 405 7 7
7 0.04 25 14.56 316 7 7
8 -0.12 201 14.19 362 7 30

Cycle 40 GMT 14/ 2/2013 23:28: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.88 32 14.42 500 7 7
2 2000.76 49 11.94 2906 7 7
3 1807.16 25 12.76 2713 6 7
4 1360.40 25 13.14 2128 6 7
5 451.88 25 14.02 918 7 7
6 35.60 25 14.51 359 7 7
7 0.16 25 14.50 308 7 7
8 -0.00 201 14.16 371 7 44

Cycle 39 GMT 5/ 2/2013 1: 3: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.56 32 14.42 538 7 7
2 2002.56 49 12.14 2935 7 7
3 1791.32 25 12.85 2676 6 7
4 1326.76 25 13.18 2086 6 7
5 614.96 25 13.83 1151 7 7
6 25.60 25 14.52 343 7 7
7 0.04 25 14.52 307 7 7
8 -0.04 201 14.17 366 7 52

Cycle 38 GMT 26/ 1/2013 2:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.84 32 14.42 538 7 7
2 2005.52 62 12.12 2946 7 7
3 1555.24 25 13.02 2382 6 7
4 891.92 25 13.60 1503 7 7
5 83.84 25 14.49 426 7 7
6 0.04 25 14.60 307 7 7
7 0.04 201 14.21 361 7 32

Cycle 37 GMT 16/ 1/2013 4:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 32 14.42 519 7 7
2 2003.36 62 12.22 2938 7 7
3 1807.44 25 12.93 2697 6 7
4 868.20 25 13.64 1476 7 7
5 157.00 25 14.43 520 7 7
6 0.24 201 14.28 350 7 18

Cycle 36 GMT 6/ 1/2013 6:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.32 32 14.42 519 7 7
2 2009.96 62 12.27 2933 7 7
3 1791.84 25 12.97 2688 6 7
4 861.92 25 13.66 1472 7 7
5 83.40 25 14.50 422 7 7
6 -0.00 25 14.65 305 7 7
7 -0.04 201 14.23 354 7 35

Cycle 35 GMT 27/12/2012 7:30:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.80 32 14.48 519 7 7
2 2004.80 62 12.32 2930 7 7
3 1565.32 25 13.11 2386 6 7
4 886.44 25 13.67 1505 7 7
5 151.56 25 14.42 522 7 7
6 0.16 201 14.28 356 7 29

Cycle 34 GMT 17/12/2012 9:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.20 32 14.36 557 7 7
2 2003.28 62 12.35 2926 7 7
3 1560.60 25 13.15 2380 6 6
4 874.92 25 13.68 1489 7 7
5 82.32 25 14.52 418 7 7
6 0.04 25 14.67 295 7 7
7 -0.08 201 14.23 361 7 25

Cycle 33 GMT 7/12/2012 10:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 32 14.48 519 7 7
2 2002.36 62 12.35 2934 7 7
3 1566.08 25 13.18 2362 6 7
4 871.00 25 13.67 1493 7 7
5 73.12 25 14.54 407 7 7
6 0.20 25 14.63 307 7 7
7 0.24 201 14.20 369 7 46

Cycle 32 GMT 27/11/2012 12:30:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 32 14.42 538 7 7
2 2005.60 62 12.36 2939 7 7
3 1338.88 25 13.27 2114 6 7
4 880.56 25 13.66 1501 7 7
5 66.52 25 14.58 403 7 7
6 0.08 25 14.65 310 7 12
7 0.16 201 14.20 369 7 37

Cycle 31 GMT 17/11/2012 14:13: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 32 14.42 538 7 7
2 2003.08 62 12.40 2923 7 7
3 1362.36 25 13.31 2143 6 7
4 710.96 25 13.85 1267 7 7
5 102.96 25 14.48 455 7 7
6 -0.04 24 14.65 307 7 7
7 -0.08 201 14.19 373 7 29

Cycle 30 GMT 7/11/2012 15:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.28 32 14.42 519 7 7
2 2004.28 62 12.41 2908 7 7
3 1557.24 25 13.20 2366 6 7
4 673.56 25 13.89 1230 7 7
5 0.04 25 14.67 310 7 7
6 -0.00 201 14.23 368 7 18

Cycle 29 GMT 28/10/2012 17:14: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.64 32 14.42 538 7 7
2 2004.52 62 12.40 2934 7 7
3 1534.04 25 13.20 2363 6 7
4 854.80 25 13.73 1465 7 7
5 155.80 25 14.49 524 7 7
6 0.12 25 14.66 314 7 7
7 0.20 201 14.23 369 7 31

Cycle 28 GMT 18/10/2012 18:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.36 32 14.42 519 7 7
2 2001.84 62 12.42 2929 7 7
3 1352.20 25 13.33 2116 6 7
4 888.36 25 13.69 1507 7 7
5 146.24 25 14.48 517 7 7
6 0.60 25 14.65 307 7 11
7 0.28 201 14.19 376 7 21

Cycle 27 GMT 8/10/2012 20:28: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.68 32 14.42 519 7 7
2 2005.32 62 12.40 2934 7 7
3 1572.56 25 13.20 2382 6 7
4 882.48 25 13.70 1501 6 7
5 161.48 25 14.44 538 7 7
6 0.16 25 14.65 314 7 7
7 0.08 201 14.20 367 7 32

Cycle 26 GMT 28/ 9/2012 21:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.76 32 14.42 538 7 7
2 2004.16 62 12.42 2925 7 7
3 1542.56 25 13.19 2366 6 7
4 865.28 25 13.70 1476 7 7
5 70.72 25 14.55 413 7 7
6 0.16 25 14.65 314 7 7
7 0.12 201 14.18 374 7 19

Cycle 25 GMT 18/ 9/2012 23:29: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.76 32 14.42 538 7 7
2 2002.44 62 12.43 2915 7 7
3 1362.96 25 13.34 2111 6 7
4 900.44 25 13.66 1518 6 7
5 72.32 25 14.53 416 7 7
6 -0.00 25 14.63 310 7 7
7 -0.04 201 14.16 375 7 33

Cycle 24 GMT 9/ 9/2012 1: 1: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.48 32 14.42 538 7 7
2 2018.28 62 12.42 2932 7 7
3 1805.48 25 13.04 2695 6 7
4 1017.44 25 13.56 1684 6 7
5 117.92 25 14.50 476 7 7
6 0.12 24 14.67 312 7 7
7 0.08 201 14.19 365 7 32

Cycle 23 GMT 30/ 8/2012 2:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.08 32 14.42 538 7 7
2 2000.76 62 12.43 2930 7 7
3 1563.24 25 13.18 2355 6 7
4 876.24 25 13.68 1490 7 7
5 30.80 25 14.63 349 7 7
6 -0.00 25 14.60 310 7 7
7 -0.00 201 14.20 359 7 34

Cycle 22 GMT 20/ 8/2012 4:11: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.16 32 14.42 538 7 7
2 2005.52 62 12.42 2935 7 7
3 1545.20 25 13.21 2345 6 7
4 837.28 25 13.73 1441 7 7
5 62.32 25 14.59 391 7 7
6 0.76 201 14.27 341 7 25

Cycle 21 GMT 10/ 8/2012 5:48: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.00 32 14.36 557 7 7
2 2005.64 62 12.47 2916 7 7
3 1558.68 25 13.21 2353 6 7
4 844.36 25 13.73 1451 7 7
5 76.80 25 14.59 422 7 7
6 0.16 25 14.70 316 7 7
7 0.08 201 14.24 348 7 38

Cycle 20 GMT 31/ 7/2012 7:34: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.36 31 14.48 519 7 7
2 2003.00 62 12.48 2916 7 7
3 1547.88 25 13.20 2370 6 7
4 1086.80 25 13.51 1786 6 7
5 146.84 25 14.53 505 7 7
6 0.08 25 14.73 310 7 7
7 0.04 201 14.26 342 7 27

Cycle 19 GMT 21/ 7/2012 9:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.96 31 14.42 557 7 7
2 2003.52 62 12.49 2926 7 7
3 1554.36 25 13.17 2403 6 7
4 846.64 25 13.73 1449 7 7
5 158.56 25 14.49 524 7 7
6 0.28 25 14.74 312 7 7
7 0.12 201 14.26 346 7 31

Cycle 18 GMT 11/ 7/2012 10:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.12 31 14.42 538 7 7
2 2003.00 62 12.48 2954 7 7
3 1558.52 25 13.17 2399 6 7
4 848.60 25 13.71 1461 7 7
5 162.84 25 14.44 549 7 7
6 -0.04 200 14.31 343 7 12

Cycle 17 GMT 1/ 7/2012 12:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.72 31 14.48 519 7 7
2 2001.92 62 12.49 2940 7 7
3 1339.00 25 13.30 2107 6 7
4 870.24 25 13.66 1509 6 7
5 70.92 25 14.59 413 7 7
6 -0.12 201 14.30 341 7 18

Cycle 16 GMT 21/ 6/2012 14:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.92 31 14.48 519 7 7
2 2001.76 68 12.39 2936 7 7
3 1309.04 25 13.34 2060 6 7
4 611.52 25 13.94 1151 7 7
5 63.88 25 14.60 405 7 7
6 0.16 220 14.29 347 7 39

Cycle 15 GMT 11/ 6/2012 15:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 31 14.48 538 7 7
2 2004.32 68 12.45 2923 7 7
3 1311.44 25 13.35 2053 6 7
4 426.44 25 14.18 887 7 7
5 75.00 25 14.65 403 7 7
6 0.12 25 14.77 305 7 7
7 0.12 221 14.28 351 7 146

Cycle 14 GMT 1/ 6/2012 17:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.88 31 14.48 538 7 7
2 2002.12 68 12.48 2928 7 7
3 1301.60 25 13.34 2062 6 7
4 837.56 25 13.74 1443 7 7
5 62.96 25 14.68 395 7 7
6 0.08 25 14.80 305 7 7
7 -0.00 220 14.30 350 7 130

Cycle 13 GMT 22/ 5/2012 19: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.28 31 14.55 519 7 7
2 2000.88 68 12.46 2925 7 7
3 1331.48 25 13.29 2099 6 7
4 622.04 25 13.93 1166 7 7
5 68.16 25 14.64 413 7 7
6 0.04 25 14.80 308 7 7
7 -0.00 221 14.29 347 7 145

Cycle 12 GMT 12/ 5/2012 20:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.56 31 14.55 519 7 7
2 2002.44 68 12.50 2921 7 7
3 1291.08 25 13.35 2022 6 7
4 618.64 25 13.96 1151 7 7
5 72.72 25 14.69 403 7 7
6 0.20 25 14.81 303 7 7
7 0.16 221 14.32 337 7 137

Cycle 11 GMT 2/ 5/2012 21:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 31 14.55 519 7 7
2 2001.68 68 12.52 2911 7 7
3 1306.76 25 13.31 2062 6 7
4 617.88 25 13.92 1157 7 7
5 70.12 25 14.67 403 7 7
6 -0.04 25 14.77 314 7 7
7 -0.00 221 14.28 352 7 149

Cycle 10 GMT 22/ 4/2012 23:20: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.24 31 14.55 538 7 7
2 1954.36 68 12.51 2871 7 7
3 1255.60 25 13.31 1993 6 7
4 573.84 25 13.96 1099 7 7
5 66.76 25 14.68 399 7 7
6 -0.00 25 14.82 303 7 7
7 -0.12 222 14.29 350 7 159

Cycle 9 GMT 12/ 4/2012 23:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.92 31 14.55 519 7 7
2 2000.92 68 12.52 2892 7 7
3 1304.28 25 13.25 2062 6 7
4 622.72 25 13.92 1147 7 7
5 72.72 25 14.67 409 7 7
6 0.16 25 14.82 295 7 7
7 0.20 221 14.30 352 7 147

Cycle 8 GMT 3/ 4/2012 1:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.60 31 14.48 519 7 7
2 1311.52 68 13.03 2058 7 7
3 1097.76 25 13.43 1780 6 7
4 614.84 25 13.90 1149 7 7
5 56.28 25 14.70 378 7 7
6 0.24 220 14.34 340 7 60

Cycle 7 GMT 24/ 3/2012 3:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.56 30 14.55 538 7 7
2 1584.24 68 12.81 2386 7 7
3 1144.40 25 13.33 1840 6 7
4 441.36 25 14.14 901 7 7
5 46.96 25 14.74 357 7 7
6 0.08 220 14.35 330 7 53

Cycle 6 GMT 14/ 3/2012 4:47: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.56 30 14.55 519 7 7
2 2002.80 68 12.49 2871 7 7
3 1308.88 25 13.19 2026 6 7
4 627.92 25 13.86 1149 7 7
5 80.80 25 14.66 411 7 7
6 15.56 24 14.73 312 7 7
7 0.16 220 14.25 357 7 123

Cycle 5 GMT 4/ 3/2012 6:18: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.36 30 14.61 500 7 7
2 2003.76 68 12.51 2773 7 7
3 1322.72 25 13.11 2070 6 7
4 646.20 25 13.81 1178 7 7
5 68.88 24 14.65 401 7 7
6 0.16 25 14.77 299 7 7
7 0.20 220 14.19 353 7 130

Cycle 4 GMT 23/ 2/2012 7:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.20 30 14.61 442 7 7
2 1515.84 68 12.81 2300 7 7
3 1084.60 25 13.29 1765 7 7
4 375.76 25 14.20 820 7 7
5 49.80 25 14.68 370 7 7
6 0.24 220 14.29 324 7 65

Cycle 3 GMT 22/ 2/2012 7:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.48 30 14.61 423 7 7
2 1503.88 69 12.77 2267 7 7
3 1285.80 25 13.09 2034 6 7
4 545.00 25 13.90 1045 7 7
5 51.32 25 14.67 374 7 7
6 0.08 220 14.30 290 7 49

Cycle 2 GMT 21/ 2/2012 8:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.48 30 14.48 461 7 7
2 1503.36 68 12.69 2224 7 7
3 1288.68 25 13.00 2032 7 7
4 551.16 25 13.83 1053 7 7
5 56.20 25 14.63 376 7 7
6 -0.08 242 14.26 290 7 154

Cycle 1 GMT 20/ 2/2012 8:50: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.88 25 14.61 403 7 7
2 1113.68 2 13.91 1788 7 7
3 1078.28 69 12.83 1745 7 7
4 107.68 25 14.42 451 7 7
5 0.16 25 14.69 297 7 7
6 0.12 223 14.20 287 7 147

Cycle 0 GMT 19/ 2/2012 23:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 74.36 68 14.42 377 154 7
2 67.96 25 14.51 359 7 7
3 35.20 25 14.55 314 7 7
4 0.20 25 14.70 270 7 7
5 0.20 218 14.30 266 7 136