SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8493 WMO= 1902025


Cycle 298 GMT 17/12/2024 22:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 22 14.93 433 2 2
2 12 1109.28 1 14.92 1976 2 2
3 7 2009.00 43 14.23 3174 2 2
4 13 1603.56 27 14.19 2656 2 2
5 13 711.72 27 14.52 1409 2 2
6 13 75.00 27 14.84 433 2 2
7 13 22.40 27 14.85 337 2 2
8 8 -0.40 190 14.81 295 2 2

Cycle 297 GMT 7/12/2024 23:21: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 22 14.92 437 2 2
2 12 1120.88 1 14.92 2009 2 2
3 7 2007.92 43 14.24 3157 2 2
4 13 1876.68 27 14.15 2992 2 2
5 13 939.28 27 14.43 1717 2 2
6 13 535.20 27 14.64 964 2 2
7 13 535.20 27 14.71 673 2 2
8 13 535.20 27 14.81 327 2 2
9 8 -0.08 190 14.84 275 2 2

Cycle 296 GMT 28/11/2024 0:14: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 21 14.93 460 2 2
2 10 1001.20 5 14.87 1800 2 2
3 3 870.08 -2 15.28 0 2 2
4 3 940.92 -1 15.29 0 2 2
5 12 1089.56 1 14.93 1935 2 2
6 7 2002.32 43 14.23 3157 2 2
7 13 1740.20 27 14.16 2843 2 2
8 13 700.68 27 14.55 1390 2 2
9 13 400.04 27 14.77 656 2 2
10 13 19.96 27 14.86 328 2 2
11 8 -0.48 190 14.82 292 2 2

Cycle 295 GMT 18/11/2024 0:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 22 14.95 417 2 2
2 3 969.64 -1 15.30 0 2 2
3 3 1030.40 1 15.00 1876 2 2
4 12 1137.52 1 14.92 2001 2 2
5 7 2008.40 43 14.23 3169 2 2
6 13 1443.60 27 14.25 2416 2 2
7 13 1167.00 27 14.29 2033 2 2
8 13 94.40 27 14.83 461 2 2
9 13 48.04 27 14.84 380 2 2
10 8 -0.56 190 14.82 295 2 2

Cycle 294 GMT 8/11/2024 1:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 22 14.96 431 2 2
2 12 1096.28 1 14.94 1949 2 2
3 7 2013.48 43 14.21 3197 2 2
4 13 1887.16 27 14.13 3026 2 2
5 13 1099.80 27 14.34 1952 2 2
6 13 74.16 27 14.87 427 2 2
7 13 41.72 27 14.87 363 2 2
8 8 -0.32 190 14.84 291 2 2

Cycle 293 GMT 29/10/2024 1:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 22 14.98 435 2 2
2 12 1113.00 1 14.92 1987 2 2
3 7 2002.64 43 14.24 3138 2 2
4 13 1721.92 27 14.20 2695 2 2
5 13 988.80 27 14.41 1792 2 2
6 13 200.12 27 14.80 632 2 2
7 13 45.48 27 14.87 372 2 2
8 8 -0.44 190 14.83 295 2 2

Cycle 292 GMT 19/10/2024 2: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 22 14.98 430 2 2
2 12 1103.96 1 14.93 1953 2 2
3 7 2010.52 43 14.24 3153 2 2
4 13 1880.80 27 14.15 3040 2 2
5 13 805.76 27 14.53 1553 2 2
6 13 93.04 27 14.87 458 2 2
7 8 -0.32 190 14.87 290 2 2

Cycle 291 GMT 9/10/2024 2:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 22 14.96 437 2 2
2 12 1125.08 1 14.93 1989 2 2
3 7 2006.00 43 14.23 3171 2 2
4 13 1580.80 27 14.22 2612 2 2
5 13 696.92 27 14.56 1378 2 2
6 13 63.32 27 14.88 409 2 2
7 8 -0.40 190 14.86 292 2 2

Cycle 290 GMT 29/ 9/2024 1:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 21 14.95 451 2 2
2 12 1123.28 1 14.94 2011 2 2
3 7 2003.32 43 14.25 3167 2 2
4 13 1453.04 27 14.26 2445 2 2
5 13 749.76 27 14.53 1461 2 2
6 13 69.76 27 14.87 427 2 2
7 13 36.44 27 14.87 363 2 2
8 8 -0.28 190 14.84 305 2 2

Cycle 289 GMT 19/ 9/2024 1:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 21 14.96 431 2 2
2 12 1149.44 1 14.93 2026 2 2
3 7 2005.08 43 14.25 3158 2 2
4 13 1605.68 27 14.23 2646 2 2
5 13 1006.00 27 14.40 1814 2 2
6 13 209.52 27 14.79 652 2 2
7 8 -0.24 190 14.85 300 2 2

Cycle 288 GMT 9/ 9/2024 1:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 22 14.90 445 2 2
2 12 1104.40 1 14.95 1974 2 2
3 7 2010.88 43 14.24 3181 2 2
4 13 1886.68 27 14.17 3023 2 2
5 13 784.96 27 14.54 1509 2 2
6 13 88.44 27 14.88 458 2 2
7 13 45.56 27 14.88 378 2 2
8 8 -0.12 190 14.85 294 2 2

Cycle 287 GMT 30/ 8/2024 1:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 21 14.97 452 2 2
2 12 1121.12 1 14.93 1989 2 2
3 7 2005.56 43 14.24 3188 2 2
4 13 1590.28 27 14.32 2616 2 2
5 13 837.92 27 14.62 1569 2 2
6 13 62.92 27 14.95 410 2 2
7 13 33.04 27 14.95 358 2 2
8 8 -0.32 190 14.90 299 2 2

Cycle 286 GMT 20/ 8/2024 1:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 22 14.99 440 2 2
2 12 1090.32 1 14.94 1952 2 2
3 7 2007.04 43 14.24 3185 2 2
4 13 1875.00 27 14.15 3028 2 2
5 13 945.72 27 14.48 1737 2 2
6 13 146.04 27 14.86 545 2 2
7 13 32.80 27 14.91 348 2 2
8 8 -0.36 190 14.87 291 2 2

Cycle 285 GMT 10/ 8/2024 1: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 22 14.99 437 2 2
2 12 1099.00 1 14.94 1942 2 2
3 7 2004.84 43 14.24 3165 2 2
4 13 1733.76 27 14.19 2837 2 2
5 13 717.76 27 14.60 1422 2 2
6 13 114.92 27 14.88 501 2 2
7 8 -0.24 190 14.89 295 2 2

Cycle 284 GMT 31/ 7/2024 0:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 22 14.98 449 2 2
2 12 1095.28 1 14.93 1954 2 2
3 7 2003.68 43 14.24 3148 2 2
4 13 1730.36 27 14.20 2783 2 2
5 13 697.24 27 14.61 1387 2 2
6 13 266.44 27 14.82 667 2 2
7 8 -0.36 190 14.88 291 2 2

Cycle 283 GMT 21/ 7/2024 0:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 22 15.00 450 2 2
2 12 1115.84 1 14.92 1983 2 2
3 7 2006.44 43 14.22 3185 2 2
4 13 1470.08 27 14.27 2460 2 2
5 13 756.12 27 14.57 1463 2 2
6 13 72.24 27 14.90 421 2 2
7 13 36.40 27 14.91 358 2 2
8 8 -0.28 190 14.87 292 2 2

Cycle 282 GMT 11/ 7/2024 0: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 22 14.99 442 2 2
2 12 1106.96 1 14.92 1968 2 2
3 7 2005.96 44 14.21 3182 2 2
4 13 1728.00 27 14.18 2802 2 2
5 13 857.32 27 14.54 1605 2 2
6 13 59.00 27 14.93 405 2 2
7 8 -0.40 190 14.90 302 2 2

Cycle 281 GMT 30/ 6/2024 23:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 21 15.00 450 2 2
2 3 1024.84 1 15.02 1850 2 2
3 12 1118.60 1 14.92 1993 2 2
4 7 2004.20 43 14.24 3143 2 2
5 13 1604.28 27 14.24 2652 2 2
6 13 857.48 27 14.53 1602 2 2
7 13 102.84 27 14.89 482 2 2
8 8 -0.36 190 14.89 303 2 2

Cycle 280 GMT 20/ 6/2024 23:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 21 14.99 422 2 2
2 12 1136.00 1 14.91 2017 2 2
3 7 2005.08 43 14.22 3170 2 2
4 13 1585.12 27 14.24 2614 2 2
5 13 838.80 27 14.54 1587 2 2
6 13 62.56 27 14.92 405 2 2
7 13 38.32 27 14.91 362 2 2
8 8 -0.16 190 14.88 298 2 2

Cycle 279 GMT 10/ 6/2024 23:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 21 15.00 430 2 2
2 12 1118.12 1 14.91 2002 2 2
3 7 2004.60 44 14.21 3161 2 2
4 13 1462.40 27 14.29 2439 2 2
5 13 717.04 27 14.59 1420 2 2
6 13 74.60 27 14.90 425 2 2
7 13 41.52 27 14.91 365 2 2
8 8 -0.32 190 14.87 302 2 2

Cycle 278 GMT 31/ 5/2024 22:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 22 15.00 445 2 2
2 12 1102.16 1 14.91 1970 2 2
3 7 2003.48 43 14.23 3155 2 2
4 13 1589.56 27 14.24 2626 2 2
5 13 715.76 27 14.60 1402 2 2
6 13 75.92 27 14.91 422 2 2
7 13 40.32 27 14.92 365 2 2
8 8 -0.36 190 14.88 297 2 2

Cycle 277 GMT 21/ 5/2024 22:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 22 15.00 428 2 2
2 12 1121.76 1 14.92 1998 2 2
3 7 2002.88 44 14.24 3111 2 2
4 13 1589.96 27 14.24 2602 2 2
5 13 699.60 27 14.61 1376 2 2
6 13 70.28 27 14.92 410 2 2
7 13 38.76 27 14.92 354 2 2
8 8 -0.24 190 14.88 293 2 2

Cycle 276 GMT 11/ 5/2024 22: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 21 15.00 430 2 2
2 12 1119.48 1 14.91 1984 2 2
3 7 2005.96 43 14.22 3166 2 2
4 13 1742.52 27 14.19 2823 2 2
5 13 981.24 27 14.46 1774 2 2
6 13 103.08 27 14.90 467 2 2
7 13 31.56 27 14.93 341 2 2
8 8 -0.32 190 14.89 290 2 2

Cycle 275 GMT 1/ 5/2024 21:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 22 15.00 419 2 2
2 3 964.52 -1 15.32 0 2 2
3 12 1124.48 1 14.92 1970 2 2
4 7 2004.04 43 14.23 3163 2 2
5 13 1476.84 27 14.28 2473 2 2
6 13 871.88 27 14.50 1637 2 2
7 13 104.44 27 14.88 473 2 2
8 13 28.44 27 14.91 338 2 2
9 8 -0.56 190 14.87 290 2 2

Cycle 274 GMT 21/ 4/2024 20:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 22 15.01 444 2 2
2 12 1088.68 1 14.93 1949 2 2
3 7 2005.92 43 14.23 3165 2 2
4 13 1599.16 27 14.24 2631 2 2
5 13 710.88 27 14.60 1401 2 2
6 13 110.24 27 14.88 490 2 2
7 13 26.76 27 14.91 345 2 2
8 8 -0.44 190 14.87 296 2 2

Cycle 273 GMT 11/ 4/2024 20:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 23 14.91 433 2 2
2 12 1116.56 1 14.92 1973 2 2
3 7 2002.84 43 14.24 3140 2 2
4 13 1583.04 27 14.25 2604 2 2
5 13 592.96 27 14.67 1231 2 2
6 13 87.08 27 14.91 449 2 2
7 13 25.88 27 14.93 337 2 2
8 8 -0.24 190 14.89 292 2 2

Cycle 272 GMT 1/ 4/2024 20: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 22 14.92 433 2 2
2 12 1114.84 1 14.91 2009 2 2
3 7 2003.32 43 14.24 3140 2 2
4 13 1587.56 27 14.25 2617 2 2
5 13 1309.56 27 14.29 2188 2 2
6 13 914.52 27 14.53 1452 2 2
7 13 914.52 27 14.59 1153 2 2
8 13 914.52 27 14.68 797 2 2
9 8 -0.48 190 14.82 299 2 2

Cycle 271 GMT 22/ 3/2024 20:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 23 14.89 452 2 2
2 12 1106.12 1 14.94 1972 2 2
3 7 2003.56 43 14.24 3169 2 2
4 13 1453.76 27 14.29 2433 2 2
5 13 1021.36 27 14.42 1830 2 2
6 13 735.88 27 14.55 1336 2 2
7 13 735.88 27 14.61 1049 2 2
8 13 735.88 27 14.71 705 2 2
9 8 -0.52 190 14.81 291 2 3

Cycle 270 GMT 12/ 3/2024 21:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 22 14.94 426 2 2
2 12 1126.24 1 14.94 1999 2 2
3 7 2007.84 43 14.25 3188 2 2
4 13 1877.60 27 14.17 3004 2 2
5 13 914.60 27 14.49 1681 2 2
6 13 854.20 27 14.52 1439 2 2
7 13 854.20 27 14.58 1149 2 2
8 13 854.20 27 14.68 779 2 2
9 8 -0.28 190 14.81 298 2 3

Cycle 269 GMT 2/ 3/2024 22:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 23 14.95 437 2 2
2 12 1117.80 1 14.94 1985 2 2
3 7 2007.36 43 14.26 3145 2 2
4 13 1891.88 27 14.16 3013 2 2
5 13 1596.12 27 14.25 2358 2 2
6 13 1596.12 27 14.25 2102 2 2
7 13 54.20 27 14.97 361 2 2
8 8 -0.04 190 14.93 286 2 2

Cycle 268 GMT 21/ 2/2024 23:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 23 14.92 431 2 2
2 12 1098.24 1 14.95 1947 2 2
3 7 2003.48 43 14.27 3144 2 2
4 13 1689.60 27 14.30 2742 2 2
5 13 819.32 27 14.66 1541 2 2
6 13 128.24 27 15.00 488 2 2
7 13 70.80 27 15.01 384 2 2
8 8 -0.12 190 14.98 284 2 2

Cycle 267 GMT 11/ 2/2024 23:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 18 14.92 424 2 2
2 10 1027.96 3 14.87 1846 2 2
3 3 1054.76 1 14.90 1909 2 2
4 3 1021.16 1 15.01 1858 2 2
5 12 1099.56 1 14.94 1960 2 2
6 7 2003.72 43 14.26 3175 2 2
7 13 1572.48 27 14.35 2562 2 2
8 13 732.04 27 14.72 1410 2 2
9 13 127.52 27 14.96 515 2 2
10 13 73.12 27 14.96 396 2 2
11 8 -0.24 190 14.93 285 2 2

Cycle 266 GMT 1/ 2/2024 23:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 22 14.91 430 2 2
2 3 953.24 -1 15.29 0 2 2
3 3 952.56 -1 15.31 0 2 2
4 7 1063.96 43 14.71 1874 2 2
5 13 981.68 27 14.64 1764 2 2
6 13 588.64 27 14.67 1204 2 2
7 13 63.68 27 14.87 395 2 2
8 8 -0.40 190 14.85 279 2 2

Cycle 265 GMT 23/ 1/2024 0:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 22 14.96 414 2 2
2 3 1020.00 1 15.03 1882 2 2
3 7 992.80 43 14.74 1778 2 2
4 13 901.76 27 14.68 1656 2 2
5 13 367.36 27 14.76 884 2 2
6 13 67.12 27 14.87 392 2 2
7 13 35.52 27 14.87 333 2 2
8 8 -0.24 190 14.83 277 2 2

Cycle 264 GMT 13/ 1/2024 0:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 22 14.97 420 2 2
2 12 1094.00 1 14.96 1948 2 2
3 7 1374.52 43 14.55 2326 2 2
4 13 1268.20 27 14.48 2186 2 2
5 13 581.60 27 14.65 1201 2 2
6 13 68.08 27 14.89 396 2 2
7 8 -0.32 190 14.87 279 2 2

Cycle 263 GMT 3/ 1/2024 0: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 22 14.98 431 2 2
2 12 1105.00 1 14.99 1892 2 2
3 7 2002.00 43 14.27 3163 2 2
4 13 1461.92 27 14.30 2449 2 2
5 13 882.00 27 14.50 1637 2 2
6 13 108.36 27 14.86 481 2 2
7 13 29.96 27 14.89 337 2 2
8 8 -0.48 190 14.86 286 2 2

Cycle 262 GMT 23/12/2023 23:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 21 14.99 432 2 2
2 12 1120.32 1 14.96 1998 2 2
3 7 2001.52 43 14.28 3139 2 2
4 13 1718.24 27 14.22 2809 2 2
5 13 812.36 27 14.55 1558 2 2
6 13 91.48 27 14.88 459 2 2
7 13 10.84 27 14.91 305 2 2
8 8 -0.48 190 14.86 288 2 2

Cycle 261 GMT 13/12/2023 23: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 22 14.97 428 2 2
2 12 1089.56 1 14.96 1972 2 2
3 7 2004.12 43 14.27 3160 2 2
4 13 1727.36 27 14.23 2780 2 2
5 13 1119.28 27 14.39 1973 2 2
6 13 91.08 27 14.88 446 2 2
7 13 45.76 27 14.89 364 2 2
8 8 -0.44 190 14.86 286 2 2

Cycle 260 GMT 3/12/2023 22:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 22 14.98 437 2 2
2 12 1115.76 1 14.95 1985 2 2
3 7 2003.12 43 14.29 3126 2 2
4 13 1592.56 27 14.26 2608 2 2
5 13 1000.96 27 14.44 1812 2 2
6 13 114.24 27 14.87 482 2 2
7 13 15.12 27 14.91 306 2 2
8 8 -0.48 190 14.86 287 2 2

Cycle 259 GMT 23/11/2023 22:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 22 14.98 449 2 2
2 12 1126.16 1 14.96 2026 2 2
3 7 2005.88 44 14.28 3167 2 2
4 13 1609.60 27 14.26 2652 2 2
5 13 705.44 27 14.59 1393 2 2
6 13 121.24 27 14.86 503 2 2
7 13 14.32 27 14.90 314 2 2
8 8 -0.40 190 14.86 293 2 2

Cycle 258 GMT 13/11/2023 21:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 22 14.97 429 2 2
2 12 1112.32 1 14.97 1972 2 2
3 7 2003.12 43 14.29 3161 2 2
4 13 1726.56 27 14.24 2824 2 2
5 13 799.08 27 14.54 1544 2 2
6 13 100.84 27 14.87 475 2 2
7 8 -0.24 190 14.88 292 2 2

Cycle 257 GMT 3/11/2023 21:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 21 14.98 432 2 2
2 12 1113.20 1 14.97 1985 2 2
3 7 2015.72 43 14.28 3153 2 2
4 13 1467.08 27 14.30 2439 2 2
5 13 861.04 27 14.49 1620 2 2
6 13 108.96 27 14.86 480 2 2
7 8 -0.28 190 14.87 284 2 2

Cycle 256 GMT 24/10/2023 21: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 21 14.97 441 2 2
2 12 1121.00 1 14.97 2010 2 2
3 7 2002.56 43 14.28 3183 2 2
4 13 1581.84 27 14.27 2581 2 2
5 13 848.88 27 14.51 1600 2 2
6 13 120.28 27 14.87 492 2 2
7 8 -0.32 190 14.88 286 2 2

Cycle 255 GMT 14/10/2023 20:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 21 14.98 432 2 2
2 12 1109.40 1 14.98 1965 2 2
3 7 2008.12 43 14.29 3171 2 2
4 13 1602.68 27 14.27 2613 2 2
5 13 735.92 27 14.58 1440 2 2
6 13 128.64 27 14.85 518 2 2
7 8 -0.40 190 14.87 291 2 2

Cycle 254 GMT 4/10/2023 20: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 21 14.96 436 2 2
2 12 1116.56 1 14.97 2014 2 2
3 7 2006.04 43 14.30 3144 2 2
4 13 1606.96 27 14.27 2650 2 2
5 13 689.16 27 14.59 1380 2 2
6 13 117.76 27 14.86 496 2 2
7 8 -0.28 190 14.87 297 2 2

Cycle 253 GMT 24/ 9/2023 19:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 21 14.97 436 2 2
2 12 1109.88 1 14.97 1978 2 2
3 7 2003.84 43 14.28 3154 2 2
4 13 1595.36 27 14.27 2634 2 2
5 13 836.08 27 14.52 1580 2 2
6 13 104.56 27 14.87 465 2 2
7 8 -0.16 190 14.86 290 2 2

Cycle 252 GMT 14/ 9/2023 19:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 22 14.98 424 2 2
2 12 1091.80 1 14.97 1939 2 2
3 7 2004.60 43 14.28 3150 2 2
4 13 1597.08 27 14.27 2624 2 2
5 13 698.68 27 14.60 1388 2 2
6 13 114.00 27 14.86 487 2 2
7 8 -0.20 190 14.87 294 2 2

Cycle 251 GMT 4/ 9/2023 18:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 21 14.98 436 2 2
2 3 1028.12 1 15.08 1870 2 2
3 12 1124.36 1 14.96 2011 2 2
4 7 2004.52 43 14.30 3148 2 2
5 13 1456.08 27 14.31 2439 2 2
6 13 865.60 27 14.51 1616 2 2
7 13 139.12 27 14.87 510 2 2
8 8 -0.12 190 14.89 279 2 2

Cycle 250 GMT 25/ 8/2023 18:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 21 14.96 430 2 2
2 3 1019.80 1 15.09 1870 2 2
3 12 1115.20 1 14.97 1984 2 2
4 7 2003.64 43 14.31 3150 2 2
5 13 1596.04 27 14.29 2593 2 2
6 13 835.36 27 14.53 1586 2 2
7 13 132.92 27 14.87 520 2 2
8 8 -0.16 190 14.89 282 2 2

Cycle 249 GMT 15/ 8/2023 18:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 21 14.96 435 2 2
2 12 1090.84 1 14.99 1950 2 2
3 7 2006.56 43 14.29 3155 2 2
4 13 1874.80 27 14.20 3030 2 2
5 13 817.52 27 14.55 1560 2 2
6 13 97.28 27 14.88 461 2 2
7 8 -0.40 190 14.87 293 2 2

Cycle 248 GMT 5/ 8/2023 17:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 22 14.96 439 2 2
2 12 1101.20 1 14.98 1960 2 2
3 7 2008.36 43 14.29 3158 2 2
4 13 1875.28 27 14.21 3005 2 2
5 13 644.72 27 14.64 1320 2 2
6 13 97.92 27 14.88 471 2 2
7 13 49.68 27 14.89 379 2 2
8 8 -0.32 190 14.86 294 2 2

Cycle 247 GMT 26/ 7/2023 17:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 21 14.96 457 2 2
2 12 1096.08 1 14.98 1969 2 2
3 7 2001.00 43 14.29 3181 2 2
4 13 1451.28 27 14.31 2416 2 2
5 13 599.92 27 14.64 1240 2 2
6 13 77.40 27 14.88 431 2 2
7 8 -0.16 190 14.86 296 2 2

Cycle 246 GMT 16/ 7/2023 16:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 21 14.97 436 2 2
2 10 1004.88 3 14.96 1825 2 2
3 3 904.44 -2 15.37 0 2 2
4 3 968.68 -1 15.39 0 2 2
5 12 1155.44 1 14.96 2037 2 2
6 7 2005.12 44 14.29 3148 2 2
7 13 1463.84 27 14.31 2468 2 2
8 13 649.40 27 14.64 1318 2 2
9 13 87.04 27 14.88 456 2 2
10 8 -0.24 190 14.87 304 2 2

Cycle 245 GMT 6/ 7/2023 15:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 21 14.95 446 2 2
2 12 1104.04 1 14.98 1973 2 2
3 7 2005.84 43 14.30 3152 2 2
4 13 1599.12 27 14.28 2640 2 2
5 13 716.08 27 14.60 1403 2 2
6 13 68.28 27 14.89 415 2 2
7 8 -0.32 190 14.87 295 2 2

Cycle 244 GMT 26/ 6/2023 15:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 21 14.97 439 2 2
2 12 1129.52 1 14.97 2011 2 2
3 7 2003.04 44 14.29 3142 2 2
4 13 1587.92 27 14.28 2623 2 2
5 13 694.92 27 14.60 1390 2 2
6 13 106.04 27 14.86 487 2 2
7 13 15.40 27 14.89 329 2 2
8 8 -0.52 190 14.84 305 2 2

Cycle 243 GMT 16/ 6/2023 14:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 22 14.98 423 2 2
2 12 1094.68 1 14.98 1953 2 2
3 7 2004.04 43 14.28 3160 2 2
4 13 1872.80 27 14.21 2983 2 2
5 13 961.48 27 14.49 1753 2 2
6 13 79.16 27 14.89 441 2 2
7 13 20.12 27 14.90 331 2 2
8 8 -0.40 190 14.86 293 2 2

Cycle 242 GMT 6/ 6/2023 14:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 21 14.98 448 2 2
2 12 1083.24 1 15.00 1939 2 2
3 7 2005.16 43 14.29 3138 2 2
4 13 1457.64 27 14.34 2412 2 2
5 13 602.48 27 14.66 1233 2 2
6 13 79.08 27 14.89 424 2 2
7 8 -0.36 190 14.88 284 2 2

Cycle 241 GMT 27/ 5/2023 13:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 22 14.98 444 2 2
2 3 972.96 -1 15.40 0 2 2
3 12 1140.68 1 14.97 2034 2 2
4 7 2002.96 43 14.29 3132 2 2
5 13 1588.88 27 14.28 2618 2 2
6 13 596.92 27 14.66 1237 2 2
7 13 79.52 27 14.89 438 2 2
8 13 48.08 27 14.89 378 2 2
9 8 -0.40 190 14.86 291 2 2

Cycle 240 GMT 17/ 5/2023 12:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 22 14.98 423 2 2
2 12 1115.32 1 14.99 1985 2 2
3 7 2008.36 43 14.30 3151 2 2
4 13 1874.20 27 14.21 3022 2 2
5 13 785.32 27 14.57 1510 2 2
6 13 78.04 27 14.89 435 2 2
7 13 39.84 27 14.89 365 2 2
8 8 -0.48 190 14.86 297 2 2

Cycle 239 GMT 7/ 5/2023 12:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 22 14.97 444 2 2
2 12 1109.12 1 14.99 1981 2 2
3 7 2005.56 43 14.30 3142 2 2
4 13 1877.04 27 14.22 2990 2 2
5 13 1099.04 27 14.43 1941 2 2
6 13 134.92 27 14.87 521 2 2
7 13 16.36 27 14.91 315 2 2
8 8 -0.48 190 14.86 284 2 2

Cycle 238 GMT 27/ 4/2023 12: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 22 14.98 443 2 2
2 12 1126.60 1 14.99 2016 2 2
3 7 2026.56 43 14.30 3162 2 2
4 13 1608.16 27 14.28 2621 2 2
5 13 887.00 27 14.52 1646 2 2
6 13 66.68 27 14.89 413 2 2
7 13 36.60 27 14.88 361 2 2
8 8 -0.52 190 14.85 290 2 2

Cycle 237 GMT 17/ 4/2023 10:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 22 14.97 440 2 2
2 12 1099.52 1 14.99 1953 2 2
3 7 2015.68 43 14.30 3165 2 2
4 13 1886.52 27 14.21 3006 2 2
5 13 800.00 27 14.57 1530 2 2
6 13 45.88 27 14.91 381 2 2
7 8 -0.44 190 14.88 296 2 2

Cycle 236 GMT 7/ 4/2023 9:50: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 22 14.95 434 2 2
2 12 1121.20 1 14.98 2006 2 2
3 7 2010.04 44 14.31 3163 2 2
4 13 1453.88 27 14.35 2424 2 2
5 13 542.12 27 14.69 1149 2 2
6 13 57.36 27 14.90 396 2 2
7 8 -0.36 190 14.88 288 2 2

Cycle 235 GMT 28/ 3/2023 9:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 21 14.99 439 2 2
2 3 1028.12 1 15.06 1857 2 2
3 12 1050.04 1 15.00 1873 2 2
4 7 1691.08 43 14.42 2731 2 2
5 13 1557.44 27 14.36 2533 2 2
6 13 964.12 27 14.49 1767 2 2
7 13 71.80 27 14.88 418 2 2
8 8 -0.44 190 14.87 289 2 2

Cycle 234 GMT 18/ 3/2023 8:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 21 14.98 437 2 2
2 12 1124.20 1 14.98 2007 2 2
3 7 2006.96 44 14.30 3167 2 2
4 13 1475.52 27 14.34 2443 2 2
5 13 612.08 27 14.65 1262 2 2
6 13 81.64 27 14.89 444 2 2
7 13 22.56 27 14.91 339 2 2
8 8 -0.32 190 14.87 296 2 2

Cycle 233 GMT 8/ 3/2023 8:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 21 14.97 427 2 2
2 12 1109.04 1 14.99 1979 2 2
3 7 2004.68 44 14.31 3142 2 2
4 13 1733.60 27 14.25 2817 2 2
5 13 697.36 27 14.61 1378 2 2
6 13 110.48 27 14.87 481 2 2
7 8 -0.36 190 14.88 286 2 2

Cycle 232 GMT 26/ 2/2023 8: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 21 14.98 419 2 2
2 12 1113.24 1 14.98 1983 2 2
3 7 2011.68 43 14.30 3151 2 2
4 13 1884.48 27 14.21 3023 2 2
5 13 797.84 27 14.57 1536 2 2
6 13 95.88 27 14.89 460 2 2
7 13 21.96 27 14.91 330 2 2
8 8 -0.44 190 14.87 288 2 2

Cycle 231 GMT 16/ 2/2023 7:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 22 14.98 435 2 2
2 12 1101.48 1 14.99 1943 2 2
3 7 2004.60 43 14.30 3159 2 2
4 13 1492.20 27 14.32 2474 2 2
5 13 640.36 27 14.64 1296 2 2
6 13 84.00 27 14.88 444 2 2
7 13 21.04 27 14.91 334 2 2
8 8 -0.48 190 14.86 295 2 2

Cycle 230 GMT 6/ 2/2023 6:50: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 22 14.98 446 2 2
2 12 1108.84 1 14.98 1980 2 2
3 7 2009.40 43 14.30 3150 2 2
4 13 1735.88 27 14.26 2762 2 2
5 13 839.60 27 14.55 1586 2 2
6 13 101.12 27 14.89 463 2 2
7 13 23.80 27 14.91 328 2 2
8 8 -0.40 190 14.87 285 2 2

Cycle 229 GMT 27/ 1/2023 6: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 22 14.97 423 2 2
2 12 1101.60 1 15.00 1968 2 2
3 7 2002.44 43 14.31 3150 2 2
4 13 1468.72 27 14.33 2452 2 2
5 13 728.20 27 14.59 1428 2 2
6 13 117.68 27 14.86 499 2 2
7 13 24.72 27 14.90 334 2 2
8 8 -0.44 190 14.86 287 2 2

Cycle 228 GMT 17/ 1/2023 5:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 22 14.99 447 2 2
2 12 1103.36 1 14.99 1994 2 2
3 7 2002.88 43 14.30 3152 2 2
4 13 1578.44 27 14.30 2586 2 2
5 13 581.76 27 14.67 1204 2 2
6 13 58.88 27 14.90 402 2 2
7 13 16.64 27 14.91 321 2 2
8 8 -0.44 190 14.86 291 2 2

Cycle 227 GMT 7/ 1/2023 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 21 14.98 434 2 2
2 3 1044.04 1 15.02 1879 2 2
3 12 1090.36 1 15.00 1958 2 2
4 7 2003.72 43 14.30 3169 2 2
5 13 1740.80 27 14.25 2833 2 2
6 13 730.64 27 14.60 1449 2 2
7 13 122.76 27 14.87 507 2 2
8 13 28.04 27 14.91 346 2 2
9 8 -0.48 190 14.87 292 2 2

Cycle 226 GMT 28/12/2022 4: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 22 14.98 424 2 2
2 3 964.28 -1 15.36 0 2 2
3 12 1116.00 1 14.99 1998 2 2
4 7 2002.88 44 14.30 3131 2 2
5 13 1349.80 27 14.38 2284 2 2
6 13 922.44 27 14.49 1701 2 2
7 13 141.32 27 14.85 539 2 2
8 13 28.44 27 14.89 345 2 2
9 8 -0.48 190 14.86 292 2 2

Cycle 225 GMT 18/12/2022 3: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 21 14.98 440 2 2
2 3 1040.16 1 15.01 1860 2 2
3 12 1120.40 1 14.99 1979 2 2
4 7 2006.16 43 14.32 3159 2 2
5 13 1731.48 27 14.27 2795 2 2
6 13 804.28 27 14.57 1536 2 2
7 13 83.04 27 14.89 434 2 2
8 13 22.56 27 14.91 325 2 2
9 8 -0.48 190 14.87 284 2 2

Cycle 224 GMT 8/12/2022 2:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 21 14.97 433 2 2
2 12 1094.48 1 14.99 1995 2 2
3 7 2006.72 44 14.31 3140 2 2
4 13 1595.80 27 14.29 2645 2 2
5 13 1145.76 27 14.40 2021 2 2
6 13 91.52 27 14.89 459 2 2
7 13 49.08 27 14.90 381 2 2
8 8 -0.36 190 14.87 294 2 2

Cycle 223 GMT 28/11/2022 2:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 21 14.98 433 2 2
2 12 1108.08 1 15.01 1954 2 2
3 7 2010.36 43 14.30 3162 2 2
4 13 1466.68 27 14.34 2446 2 2
5 13 1023.92 27 14.45 1857 2 2
6 13 104.12 27 14.88 471 2 2
7 8 -0.32 190 14.88 294 2 2

Cycle 222 GMT 18/11/2022 1:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 21 14.98 428 2 2
2 12 1078.40 1 15.00 1924 2 2
3 7 2003.84 44 14.31 3135 2 2
4 13 1742.92 27 14.27 2763 2 2
5 13 803.84 27 14.56 1539 2 2
6 13 82.72 27 14.89 437 2 2
7 8 -0.32 190 14.88 289 2 2

Cycle 221 GMT 8/11/2022 1: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 21 14.97 452 2 2
2 12 1091.20 1 15.00 1971 2 2
3 7 2004.64 43 14.32 3138 2 2
4 13 1746.64 27 14.26 2830 2 2
5 13 731.52 27 14.61 1425 2 2
6 13 77.40 27 14.90 423 2 2
7 8 -0.24 190 14.89 296 2 2

Cycle 220 GMT 29/10/2022 0:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 21 14.97 446 2 2
2 12 1121.08 1 15.02 1927 2 2
3 7 2018.36 43 14.32 3176 2 2
4 13 1604.36 27 14.29 2661 2 2
5 13 849.40 27 14.54 1614 2 2
6 13 109.20 27 14.88 478 2 2
7 8 -0.32 190 14.87 296 2 2

Cycle 219 GMT 19/10/2022 0: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 21 14.98 441 2 2
2 12 1121.60 1 14.99 1988 2 2
3 7 2002.40 43 14.32 3132 2 2
4 13 1593.36 27 14.30 2654 2 2
5 13 845.84 27 14.55 1601 2 2
6 13 112.76 27 14.88 492 2 2
7 8 -0.16 190 14.88 297 2 2

Cycle 218 GMT 8/10/2022 23:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 21 14.97 431 2 2
2 12 1091.80 1 15.00 1946 2 2
3 7 2006.60 43 14.32 3136 2 2
4 13 1605.56 27 14.30 2632 2 2
5 13 1119.32 27 14.41 1956 2 2
6 13 137.56 27 14.85 524 2 2
7 8 -0.32 190 14.87 288 2 2

Cycle 217 GMT 28/ 9/2022 22:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 21 14.99 435 2 2
2 12 1073.72 1 15.01 1946 2 2
3 7 2004.24 43 14.32 3151 2 2
4 13 1597.88 27 14.29 2636 2 2
5 13 845.64 27 14.54 1600 2 2
6 13 130.40 27 14.86 514 2 2
7 8 -0.32 190 14.87 289 2 2

Cycle 216 GMT 18/ 9/2022 21:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 21 14.98 465 2 2
2 3 1026.00 1 15.05 1871 2 2
3 12 1114.84 1 15.01 1964 2 2
4 7 2008.64 44 14.31 3155 2 2
5 13 1873.92 27 14.23 3009 2 2
6 13 798.20 27 14.58 1537 2 2
7 13 115.00 27 14.89 483 2 2
8 8 -0.08 190 14.89 289 2 2

Cycle 215 GMT 8/ 9/2022 21:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 22 14.96 467 2 2
2 3 958.08 -1 15.35 0 2 2
3 12 1125.40 1 15.00 1995 2 2
4 7 2005.12 44 14.31 3154 2 2
5 13 1583.20 27 14.30 2624 2 2
6 13 588.44 27 14.67 1227 2 2
7 13 80.40 27 14.89 435 2 2
8 8 -0.08 190 14.88 299 2 2

Cycle 214 GMT 29/ 8/2022 20:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 22 14.93 464 2 2
2 3 1023.08 1 15.02 1860 2 2
3 12 1123.84 1 14.99 1977 2 2
4 7 2004.40 43 14.31 3155 2 2
5 13 1451.88 27 14.35 2425 2 2
6 13 722.16 27 14.60 1435 2 2
7 13 120.16 27 14.86 518 2 2
8 8 -0.28 190 14.86 306 2 2

Cycle 213 GMT 19/ 8/2022 20:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 20 14.98 466 2 2
2 3 1052.04 1 14.98 1901 2 2
3 12 1138.32 1 15.00 2015 2 2
4 7 1322.28 43 14.63 2247 2 2
5 13 1206.96 27 14.57 2103 2 2
6 13 483.88 27 14.72 1069 2 2
7 13 75.96 27 14.87 435 2 2
8 13 28.40 27 14.88 348 2 2
9 8 -0.32 190 14.84 299 2 2

Cycle 212 GMT 9/ 8/2022 19:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 21 14.97 430 2 2
2 12 1117.04 1 15.01 2000 2 2
3 7 2015.08 43 14.33 3147 2 2
4 13 1897.12 27 14.23 3039 2 2
5 13 713.64 27 14.62 1404 2 2
6 13 114.64 27 14.86 506 2 2
7 8 -0.08 190 14.87 306 2 2

Cycle 211 GMT 30/ 7/2022 19: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 21 14.95 445 2 2
2 12 1080.52 1 15.02 1939 2 2
3 7 2044.64 44 14.30 3186 2 2
4 13 2054.96 27 14.16 3248 2 2
5 13 871.28 27 14.55 1637 2 2
6 13 63.88 27 14.90 415 2 2
7 13 17.24 27 14.91 330 2 2
8 8 -0.32 190 14.86 301 2 4

Cycle 210 GMT 20/ 7/2022 17:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 21 14.98 433 2 2
2 12 1093.48 1 15.00 1983 2 2
3 7 2005.48 43 14.32 3147 2 2
4 13 1722.36 27 14.27 2797 2 2
5 13 792.48 27 14.57 1523 2 2
6 13 90.40 27 14.87 456 2 2
7 13 45.68 27 14.88 378 2 2
8 8 -0.32 190 14.85 302 2 2

Cycle 209 GMT 10/ 7/2022 17:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 21 14.98 442 2 2
2 12 1102.96 1 15.01 1959 2 2
3 7 2008.72 43 14.33 3141 2 2
4 13 1742.48 27 14.27 2808 2 2
5 13 693.76 27 14.62 1376 2 2
6 13 129.44 27 14.87 508 2 2
7 13 15.92 27 14.91 309 2 2
8 8 -0.12 190 14.88 286 2 2

Cycle 208 GMT 30/ 6/2022 16:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 21 14.97 450 2 2
2 12 1101.80 1 15.00 1966 2 2
3 7 2003.12 43 14.32 3143 2 2
4 13 1868.48 27 14.24 3006 2 2
5 13 641.96 27 14.64 1317 2 2
6 13 104.60 27 14.87 477 2 2
7 8 -0.20 190 14.88 293 2 2

Cycle 207 GMT 20/ 6/2022 16: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 21 14.97 443 2 2
2 3 1027.36 1 15.04 1848 2 2
3 12 1103.76 1 14.99 1978 2 2
4 7 2001.28 44 14.32 3142 2 2
5 13 1719.16 27 14.27 2807 2 2
6 13 769.12 27 14.58 1499 2 2
7 13 93.56 27 14.88 453 2 2
8 8 -0.16 190 14.87 291 2 2

Cycle 206 GMT 10/ 6/2022 15:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 21 14.97 428 2 2
2 12 1131.16 1 14.99 2020 2 2
3 7 2004.04 43 14.32 3136 2 2
4 13 1734.92 27 14.28 2768 2 2
5 13 694.52 27 14.61 1381 2 2
6 13 117.56 27 14.86 496 2 2
7 8 -0.32 190 14.87 290 2 2

Cycle 205 GMT 31/ 5/2022 15:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 20 14.96 428 2 2
2 12 1126.68 1 15.01 1982 2 2
3 7 2006.20 43 14.32 3191 2 2
4 13 1587.20 27 14.31 2619 2 2
5 13 838.48 27 14.55 1588 2 2
6 13 112.72 27 14.87 481 2 2
7 13 26.20 27 14.89 336 2 2
8 8 -0.32 190 14.86 287 2 2

Cycle 204 GMT 21/ 5/2022 14:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 20 14.97 438 2 2
2 3 1019.20 1 15.06 1860 2 2
3 12 1124.20 1 15.00 1982 2 2
4 7 2001.40 43 14.34 3139 2 2
5 13 1579.60 27 14.32 2605 2 2
6 13 985.00 27 14.48 1794 2 2
7 13 105.12 27 14.86 478 2 2
8 13 54.56 27 14.87 385 2 2
9 8 -0.28 190 14.85 289 2 2

Cycle 203 GMT 11/ 5/2022 14:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 20 14.97 424 2 2
2 12 1113.24 1 14.99 1984 2 2
3 7 2007.88 43 14.33 3168 2 2
4 13 1738.52 27 14.27 2802 2 2
5 13 810.24 27 14.55 1550 2 2
6 13 112.16 27 14.86 487 2 2
7 13 56.60 27 14.87 387 2 2
8 8 -0.40 190 14.84 291 2 2

Cycle 202 GMT 1/ 5/2022 14:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 10 14.99 420 2 2
2 10 1039.76 5 14.95 1856 2 2
3 10 1073.64 3 14.95 1890 2 2
4 3 1146.04 4 14.90 1943 2 2
5 3 1033.24 1 15.05 1868 2 2
6 12 1098.80 1 15.01 1943 2 2
7 7 2014.28 44 14.33 3169 2 2
8 13 1741.36 27 14.27 2811 2 2
9 13 808.24 27 14.55 1548 2 2
10 13 93.40 27 14.87 449 2 2
11 13 27.52 27 14.88 342 2 2
12 8 -0.24 190 14.85 293 2 2

Cycle 201 GMT 21/ 4/2022 14: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 847.92 19 14.71 1585 2 7
2 3 848.36 -3 15.38 0 2 7
3 3 848.48 -3 15.40 0 2 7
4 12 169.72 1 15.30 472 2 2
5 7 1862.72 43 14.44 2965 2 2
6 13 1447.24 27 14.41 2421 2 2
7 13 844.80 27 14.57 1591 2 2
8 13 99.32 27 14.88 461 2 2
9 13 25.12 27 14.90 334 2 2
10 8 -0.36 190 14.86 288 2 2

Cycle 200

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 21 14.91 433 2 2
2 10 1008.88 3 14.89 1826 2 2
3 3 905.48 -2 15.31 0 2 2
4 3 963.44 -1 15.33 0 2 2
5 7 848.08 44 14.87 1575 2 2
6 13 847.24 27 14.78 1585 2 2
7 13 847.16 27 14.68 1587 2 2
8 13 847.16 27 14.60 1588 2 2
9 13 847.12 27 14.54 1583 2 2
10 13 847.04 27 14.50 1588 2 2
11 13 846.96 27 14.48 1573 2 2
12 13 846.96 27 14.47 1580 2 2
13 13 846.92 27 14.46 1574 2 2
14 13 846.92 27 14.46 1572 2 2
15 13 846.92 27 14.46 1569 2 2
16 13 846.92 27 14.45 1584 2 2
17 13 846.96 27 14.45 1575 2 3
18 13 846.96 27 14.46 1574 2 5
19 13 846.96 27 14.46 1573 2 48
20 13 846.96 27 14.57 1025 2 247
21 13 847.00 27 14.70 597 247 247
22 13 847.00 27 14.76 412 247 247
23 13 847.08 27 14.78 377 247 247
24 13 847.08 27 14.83 290 247 247
25 13 847.16 27 14.84 330 247 247
26 13 847.20 27 14.86 314 247 247
27 13 847.20 27 14.88 272 247 247
28 13 847.20 27 14.90 272 247 247
29 13 847.24 27 14.91 252 247 247
30 13 848.12 27 14.91 292 247 247
31 13 848.16 27 14.95 248 247 247
32 13 848.16 27 14.97 321 247 247
33 13 848.20 27 15.00 260 247 247
34 13 848.20 27 15.02 253 247 247
35 13 848.24 27 15.03 272 247 247
36 8 848.20 1 15.03 334 247 247
37 14 848.20 169 14.99 230 247 247

Cycle 199 GMT 1/ 4/2022 2:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 22 14.95 440 2 2
2 10 1024.12 5 14.90 1843 2 2
3 3 852.16 -3 15.33 0 2 2
4 7 782.40 43 14.89 1491 2 2
5 13 712.80 27 14.83 1397 2 2
6 13 411.88 27 14.84 943 2 2
7 13 57.84 27 14.92 390 2 2
8 8 -0.28 190 14.89 289 2 2

Cycle 198 GMT 22/ 3/2022 3:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 21 14.94 428 2 2
2 10 1015.32 3 14.91 1840 2 2
3 3 915.36 -2 15.33 0 2 2
4 12 1098.20 1 15.00 1965 2 2
5 7 1252.52 43 14.65 2150 2 2
6 13 1251.44 27 14.55 2163 2 2
7 13 1149.80 27 14.48 2009 2 2
8 13 66.68 27 14.89 410 2 2
9 13 16.80 27 14.90 324 2 2
10 8 -0.24 190 14.87 286 2 2

Cycle 197 GMT 12/ 3/2022 4: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 22 14.94 422 2 2
2 3 966.16 -1 15.34 0 2 2
3 12 1149.84 1 15.01 1945 2 2
4 7 1206.24 44 14.66 2085 2 2
5 13 1107.32 27 14.60 1947 2 2
6 13 552.32 27 14.70 1152 2 2
7 13 61.84 27 14.90 384 2 2
8 13 31.20 27 14.90 331 2 2
9 8 -0.28 190 14.86 280 2 2

Cycle 196 GMT 2/ 3/2022 4: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 21 14.95 446 2 2
2 3 1055.36 1 14.96 1915 2 2
3 3 1027.12 1 15.04 1877 2 2
4 12 1129.72 1 15.00 2006 2 2
5 7 1259.24 43 14.64 2161 2 2
6 13 1133.24 27 14.58 1993 2 2
7 13 1006.60 27 14.53 1836 2 2
8 13 82.20 27 14.88 440 2 2
9 8 -0.24 190 14.87 289 2 2

Cycle 195 GMT 20/ 2/2022 4:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 22 14.99 437 2 2
2 3 951.12 -1 15.36 0 2 2
3 12 1162.28 1 14.99 2070 2 2
4 7 1672.72 43 14.46 2708 2 2
5 13 1313.04 27 14.45 2241 2 2
6 13 920.40 27 14.51 1693 2 2
7 13 252.64 27 14.78 709 2 2
8 13 40.60 27 14.87 357 2 2
9 8 -0.44 190 14.84 288 2 3

Cycle 194 GMT 10/ 2/2022 3:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 22 15.00 422 2 2
2 12 1103.76 1 15.00 1989 2 2
3 7 2005.48 44 14.32 3137 2 2
4 13 1623.48 27 14.30 2673 2 2
5 13 1071.48 27 14.44 1893 2 2
6 13 122.92 27 14.86 489 2 2
7 13 14.60 27 14.91 306 2 2
8 8 -0.40 190 14.86 283 2 2

Cycle 193 GMT 31/ 1/2022 2:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 22 15.01 433 2 2
2 12 1080.16 1 15.01 1957 2 2
3 7 2005.80 44 14.31 3162 2 2
4 13 1737.04 27 14.27 2779 2 2
5 13 614.68 27 14.63 1265 2 2
6 13 96.16 27 14.87 447 2 2
7 13 27.68 27 14.90 330 2 2
8 8 -0.28 190 14.87 281 2 2

Cycle 192 GMT 21/ 1/2022 1:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 22 14.98 442 2 2
2 12 1107.80 1 15.00 1981 2 2
3 7 2002.96 43 14.33 3147 2 2
4 13 1709.60 27 14.28 2778 2 2
5 13 814.52 27 14.54 1564 2 2
6 13 116.04 27 14.87 470 2 2
7 13 26.68 27 14.90 318 2 2
8 8 -0.28 190 14.87 279 2 2

Cycle 191 GMT 11/ 1/2022 1:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 22 15.00 424 2 2
2 3 1023.44 1 15.06 1892 2 2
3 12 1087.08 1 15.02 1950 2 2
4 7 2003.24 43 14.33 3152 2 2
5 13 1571.16 27 14.31 2613 2 2
6 13 819.72 27 14.54 1572 2 2
7 13 104.32 27 14.87 470 2 2
8 13 53.44 27 14.88 380 2 2
9 8 -0.28 190 14.86 287 2 2

Cycle 190 GMT 1/ 1/2022 0:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 22 14.99 427 2 2
2 12 1128.08 1 15.00 2016 2 2
3 7 2004.56 43 14.32 3179 2 2
4 13 1443.40 27 14.35 2411 2 2
5 13 717.96 27 14.59 1422 2 2
6 13 128.20 27 14.86 494 2 2
7 13 14.56 27 14.90 306 2 2
8 8 -0.32 190 14.86 279 2 3

Cycle 189 GMT 21/12/2021 23:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 22 14.98 439 2 2
2 3 972.12 -1 15.38 0 2 2
3 12 1149.40 1 15.00 2034 2 2
4 7 2003.68 43 14.33 3159 2 2
5 13 1440.44 27 14.35 2407 2 2
6 13 707.16 27 14.59 1405 2 2
7 13 120.72 27 14.86 489 2 2
8 8 -0.24 190 14.87 287 2 2

Cycle 188 GMT 11/12/2021 22:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 22 14.99 436 2 2
2 10 1004.40 3 14.95 1800 2 2
3 3 939.20 -1 15.36 0 2 2
4 3 968.44 -1 15.38 0 2 2
5 12 1095.44 1 15.01 1973 2 2
6 7 2001.96 43 14.33 3148 2 2
7 13 1586.64 27 14.31 2592 2 2
8 13 705.16 27 14.58 1415 2 2
9 13 126.68 27 14.86 497 2 2
10 13 13.20 27 14.90 301 2 2
11 8 -0.20 190 14.86 283 2 2

Cycle 187 GMT 1/12/2021 21:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 22 14.98 431 2 2
2 12 1119.00 1 15.01 2004 2 2
3 7 2011.68 43 14.33 3169 2 2
4 13 1466.68 27 14.34 2442 2 2
5 13 853.88 27 14.51 1622 2 2
6 13 124.24 27 14.85 501 2 2
7 8 -0.20 190 14.87 290 2 2

Cycle 186 GMT 21/11/2021 20:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 22 14.99 419 2 2
2 12 1117.28 1 15.00 2009 2 2
3 7 2010.04 43 14.32 3190 2 2
4 13 1878.00 27 14.25 2969 2 2
5 13 790.52 27 14.55 1528 2 2
6 13 154.92 27 14.84 544 2 2
7 8 -0.24 190 14.87 289 2 2

Cycle 185 GMT 11/11/2021 19:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 22 14.97 447 2 2
2 12 1133.08 1 15.01 2012 2 2
3 7 2003.60 43 14.32 3173 2 2
4 13 1430.12 27 14.35 2406 2 2
5 13 863.16 27 14.50 1626 2 2
6 13 127.48 27 14.85 503 2 2
7 8 -0.16 190 14.87 286 2 2

Cycle 184 GMT 1/11/2021 18: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 22 14.97 429 2 2
2 12 1123.52 1 15.02 1990 2 2
3 7 2008.24 43 14.33 3138 2 2
4 13 1550.12 27 14.32 2553 2 2
5 13 831.56 27 14.52 1585 2 2
6 13 195.92 27 14.81 620 2 2
7 8 -0.16 190 14.86 297 2 2

Cycle 183 GMT 22/10/2021 17: 5: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 22 14.98 449 2 2
2 12 1114.68 1 15.01 1993 2 2
3 7 2003.16 43 14.33 3155 2 2
4 13 1467.36 27 14.34 2441 2 2
5 13 702.68 27 14.58 1409 2 2
6 13 117.92 27 14.86 486 2 2
7 8 -0.20 190 14.87 291 2 2

Cycle 182 GMT 12/10/2021 16:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 22 14.96 436 2 2
2 12 1111.12 1 15.01 1974 2 2
3 7 2003.00 44 14.34 3113 2 2
4 13 1414.76 27 14.35 2353 2 2
5 13 692.60 27 14.58 1381 2 2
6 13 118.12 27 14.85 489 2 2
7 8 -0.12 190 14.87 291 2 2

Cycle 181 GMT 2/10/2021 14:37: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 22 14.98 439 2 2
2 12 1108.08 1 15.01 1998 2 2
3 7 2003.52 43 14.35 3127 2 2
4 13 1470.80 27 14.34 2449 2 2
5 13 732.12 27 14.56 1440 2 2
6 13 134.92 27 14.85 512 2 2
7 8 -0.12 190 14.87 287 2 2

Cycle 180 GMT 22/ 9/2021 13:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 22 14.98 447 2 2
2 12 1099.68 1 15.02 1957 2 2
3 7 2002.84 43 14.34 3125 2 2
4 13 1461.52 27 14.34 2416 2 2
5 13 739.76 27 14.56 1452 2 2
6 13 92.28 27 14.87 439 2 2
7 8 -0.12 190 14.87 295 2 2

Cycle 179 GMT 12/ 9/2021 11:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 22 14.97 441 2 2
2 12 1107.44 1 15.01 1984 2 2
3 7 2003.68 43 14.34 3136 2 2
4 13 1438.56 27 14.35 2401 2 2
5 13 742.68 27 14.56 1462 2 2
6 13 81.44 27 14.88 424 2 2
7 8 0.44 190 14.86 293 2 2

Cycle 178 GMT 2/ 9/2021 9:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 22 14.98 441 2 2
2 12 1103.92 1 15.02 1958 2 2
3 7 2014.80 43 14.34 3135 2 2
4 13 1595.80 27 14.31 2607 2 2
5 13 710.52 27 14.58 1417 2 2
6 13 117.68 27 14.86 491 2 2
7 8 -0.16 190 14.86 296 2 2

Cycle 177 GMT 23/ 8/2021 8:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 22 14.97 436 2 2
2 12 1114.92 1 15.03 1997 2 2
3 7 2005.40 43 14.34 3115 2 2
4 13 1602.76 27 14.31 2616 2 2
5 13 732.04 27 14.57 1437 2 2
6 13 79.96 27 14.88 425 2 2
7 8 -0.04 190 14.87 292 2 2

Cycle 176 GMT 13/ 8/2021 7: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 22 14.97 447 2 2
2 12 1105.48 2 14.95 1965 2 2
3 7 1975.32 43 14.34 3135 2 2
4 13 1840.12 27 14.27 2944 2 2
5 13 762.32 27 14.56 1494 2 2
6 13 137.72 27 14.85 530 2 2
7 8 -0.12 190 14.87 299 2 2

Cycle 175 GMT 3/ 8/2021 5:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 22 14.98 442 2 2
2 12 1096.24 2 14.96 1946 2 2
3 7 1968.16 43 14.34 3112 2 2
4 13 1432.08 27 14.35 2399 2 2
5 13 858.92 27 14.50 1614 2 2
6 13 113.92 27 14.85 478 2 2
7 8 -0.12 190 14.86 295 2 2

Cycle 174 GMT 24/ 7/2021 3:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 22 14.98 430 2 2
2 7 2004.68 43 14.35 3125 2 2
3 13 1734.52 27 14.29 2776 2 2
4 13 841.08 27 14.52 1587 2 2
5 13 126.28 27 14.86 490 2 2
6 8 -0.20 190 14.87 290 2 2

Cycle 173 GMT 14/ 7/2021 3: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 22 14.98 441 2 2
2 7 2005.28 43 14.34 3159 2 2
3 13 1604.72 27 14.31 2628 2 2
4 13 872.64 27 14.51 1626 2 2
5 13 130.88 27 14.85 499 2 2
6 8 -0.16 190 14.87 284 2 2

Cycle 172 GMT 4/ 7/2021 2:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 22 15.00 435 2 2
2 7 2004.52 43 14.35 3126 2 2
3 13 1590.60 27 14.31 2589 2 2
4 13 647.40 27 14.61 1311 2 2
5 13 102.56 27 14.87 452 2 2
6 13 24.64 27 14.90 324 2 2
7 8 -0.20 190 14.86 288 2 4

Cycle 171 GMT 24/ 6/2021 1:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 22 15.00 436 2 2
2 3 1034.48 1 15.06 1875 2 2
3 7 2007.36 43 14.35 3175 2 2
4 13 1594.16 27 14.31 2607 2 2
5 13 843.80 27 14.52 1605 2 2
6 13 135.76 27 14.86 503 2 2
7 8 -0.12 190 14.88 288 2 2

Cycle 170 GMT 14/ 6/2021 1:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 22 14.98 430 2 2
2 7 2005.32 44 14.34 3160 2 2
3 13 1595.80 27 14.31 2609 2 2
4 13 719.68 27 14.58 1421 2 2
5 13 129.64 27 14.86 497 2 2
6 8 -0.20 190 14.87 282 2 2

Cycle 169 GMT 4/ 6/2021 1:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 21 14.99 436 2 2
2 7 2009.12 43 14.35 3163 2 2
3 13 1606.32 27 14.32 2615 2 2
4 13 872.08 27 14.51 1640 2 2
5 13 124.24 27 14.86 497 2 2
6 8 -0.12 190 14.87 286 2 2

Cycle 168 GMT 25/ 5/2021 0:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 22 14.99 441 2 2
2 7 2005.96 43 14.35 3152 2 2
3 13 1872.84 27 14.27 2975 2 2
4 13 799.08 27 14.55 1536 2 2
5 13 102.52 27 14.88 454 2 2
6 8 -0.12 190 14.88 284 2 2

Cycle 167 GMT 15/ 5/2021 0:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 22 14.98 440 2 2
2 7 2003.60 44 14.35 3157 2 2
3 13 1575.00 27 14.32 2595 2 2
4 13 955.72 27 14.47 1737 2 2
5 13 89.24 27 14.87 435 2 2
6 8 -0.12 190 14.86 292 2 2

Cycle 166 GMT 5/ 5/2021 0:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 21 14.99 433 2 2
2 7 2002.84 43 14.35 3160 2 2
3 13 1732.60 27 14.29 2816 2 2
4 13 833.12 27 14.52 1587 2 2
5 13 111.48 27 14.86 484 2 2
6 13 29.72 27 14.89 347 2 2
7 8 -0.44 190 14.85 294 2 2

Cycle 165 GMT 24/ 4/2021 23:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 21 14.98 424 2 2
2 7 2008.36 43 14.35 3159 2 2
3 13 1594.28 27 14.32 2614 2 2
4 13 996.12 27 14.45 1793 2 2
5 13 118.64 27 14.85 490 2 2
6 13 34.08 27 14.88 348 2 2
7 8 -0.20 190 14.85 288 2 2

Cycle 164 GMT 14/ 4/2021 23:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 21 14.99 429 2 2
2 7 2003.36 43 14.37 3120 2 2
3 13 1605.36 27 14.32 2625 2 2
4 13 1008.68 27 14.45 1822 2 2
5 13 116.32 27 14.86 490 2 2
6 13 28.72 27 14.89 343 2 2
7 8 -0.24 190 14.86 292 2 2

Cycle 163 GMT 4/ 4/2021 23:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 21 14.97 421 2 2
2 7 2001.84 44 14.35 3145 2 2
3 13 1582.48 27 14.32 2599 2 2
4 13 710.44 27 14.58 1411 2 2
5 13 73.72 27 14.88 418 2 2
6 13 38.92 27 14.88 357 2 2
7 8 -0.44 190 14.85 292 2 2

Cycle 162 GMT 25/ 3/2021 23: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 22 14.99 428 2 2
2 7 2007.16 43 14.36 3145 2 2
3 13 1453.44 27 14.35 2434 2 2
4 13 771.28 27 14.54 1507 2 2
5 13 80.36 27 14.86 437 2 2
6 13 42.32 27 14.87 369 2 2
7 8 -0.48 190 14.83 298 2 2

Cycle 161 GMT 15/ 3/2021 22:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 22 15.01 416 2 2
2 7 2004.12 43 14.35 3157 2 2
3 13 1733.76 27 14.29 2816 2 2
4 13 702.64 27 14.58 1407 2 2
5 13 132.60 27 14.85 521 2 2
6 13 29.68 27 14.89 343 2 2
7 8 -0.32 190 14.85 292 2 2

Cycle 160 GMT 5/ 3/2021 22:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 22 14.98 419 2 2
2 7 2003.48 43 14.36 3151 2 2
3 13 1744.28 27 14.30 2718 2 2
4 13 742.72 27 14.57 1462 2 2
5 13 155.80 27 14.84 553 2 2
6 13 35.60 27 14.89 347 2 2
7 8 -0.32 190 14.85 289 2 2

Cycle 159 GMT 23/ 2/2021 21:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 22 14.99 439 2 2
2 7 2009.00 43 14.35 3167 2 2
3 13 1884.08 27 14.27 3034 2 2
4 13 949.84 27 14.48 1744 2 2
5 13 159.76 27 14.83 570 2 2
6 13 38.68 27 14.89 360 2 2
7 8 -0.36 190 14.85 292 2 2

Cycle 158 GMT 13/ 2/2021 20:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 21 14.99 431 2 2
2 7 2002.00 43 14.36 3159 2 2
3 13 1455.84 27 14.36 2439 2 2
4 13 748.20 27 14.55 1477 2 2
5 13 148.36 27 14.84 541 2 2
6 13 16.20 27 14.89 314 2 2
7 8 -0.28 190 14.85 287 2 2

Cycle 157 GMT 3/ 2/2021 20:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 21 14.99 427 2 2
2 7 2005.00 43 14.37 3157 2 2
3 13 1597.16 27 14.32 2642 2 2
4 13 861.76 27 14.51 1619 2 2
5 13 141.60 27 14.85 525 2 2
6 13 35.32 27 14.89 349 2 2
7 8 -0.28 190 14.86 289 2 2

Cycle 156 GMT 24/ 1/2021 19:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 21 15.00 424 2 2
2 3 1028.80 1 15.08 1895 2 2
3 7 2004.56 43 14.36 3154 2 2
4 13 1464.80 27 14.36 2448 2 2
5 13 754.20 27 14.56 1480 2 2
6 13 150.24 27 14.84 546 2 2
7 13 36.40 27 14.88 350 2 2
8 8 -0.20 190 14.85 284 2 2

Cycle 155 GMT 14/ 1/2021 18:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 22 14.99 425 2 2
2 3 972.96 -1 15.41 0 2 2
3 7 2003.00 43 14.36 3152 2 2
4 13 1739.48 27 14.30 2830 2 2
5 13 719.56 27 14.59 1431 2 2
6 13 143.36 27 14.86 527 2 2
7 13 34.88 27 14.90 340 2 2
8 8 -0.32 190 14.87 290 2 2

Cycle 154 GMT 4/ 1/2021 18:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 21 14.99 424 2 2
2 7 2001.96 43 14.37 3144 2 2
3 13 1576.36 27 14.34 2596 2 2
4 13 847.48 27 14.52 1610 2 2
5 13 128.36 27 14.86 505 2 2
6 8 -0.08 190 14.87 286 2 2

Cycle 153 GMT 25/12/2020 17:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 22 14.98 423 2 2
2 7 2004.84 43 14.37 3111 2 2
3 13 1733.68 27 14.30 2800 2 2
4 13 815.84 27 14.54 1554 2 2
5 13 122.84 27 14.86 491 2 2
6 13 30.52 27 14.90 333 2 2
7 8 -0.36 190 14.86 283 2 2

Cycle 152 GMT 15/12/2020 16:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 22 14.98 432 2 2
2 7 2002.28 43 14.38 3097 2 2
3 13 1596.96 27 14.33 2607 2 2
4 13 996.76 27 14.45 1799 2 2
5 13 202.20 27 14.80 625 2 2
6 13 21.60 27 14.88 315 2 2
7 8 -0.24 190 14.85 284 2 2

Cycle 151 GMT 5/12/2020 16:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 22 14.98 435 2 2
2 7 2003.24 43 14.37 3148 2 2
3 13 1868.76 27 14.29 2991 2 2
4 13 944.12 27 14.50 1734 2 2
5 13 161.00 27 14.84 562 2 2
6 13 38.96 27 14.89 350 2 2
7 8 -0.28 190 14.86 286 2 2

Cycle 150 GMT 25/11/2020 16: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 22 14.99 434 2 2
2 7 2001.68 44 14.37 3129 2 2
3 13 1715.20 27 14.31 2762 2 2
4 13 690.68 27 14.60 1385 2 2
5 13 129.16 27 14.86 503 2 2
6 13 30.28 27 14.90 332 2 2
7 8 -0.16 190 14.86 283 2 2

Cycle 149 GMT 15/11/2020 15:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 21 14.99 443 2 2
2 3 1028.84 1 15.10 1887 2 2
3 7 2005.28 43 14.38 3156 2 2
4 13 1739.12 27 14.31 2808 2 2
5 13 860.00 27 14.53 1628 2 2
6 13 130.40 27 14.86 511 2 2
7 13 15.88 27 14.90 311 2 2
8 8 -0.20 190 14.86 288 2 2

Cycle 148 GMT 5/11/2020 14:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 21 14.97 434 2 2
2 7 2004.00 43 14.38 3146 2 2
3 13 1727.60 27 14.32 2795 2 2
4 13 789.96 27 14.56 1521 2 2
5 13 115.48 27 14.87 476 2 2
6 8 -0.12 190 14.88 283 2 2

Cycle 147 GMT 26/10/2020 14:38: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 21 14.98 423 2 2
2 3 1018.80 1 15.12 1864 2 2
3 7 2005.36 43 14.38 3132 2 2
4 13 1464.64 27 14.37 2432 2 2
5 13 738.44 27 14.58 1443 2 2
6 13 137.48 27 14.84 525 2 2
7 13 14.60 27 14.89 307 2 2
8 8 -0.28 190 14.85 286 2 2

Cycle 146 GMT 16/10/2020 14:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 21 14.99 425 2 2
2 7 2005.04 43 14.38 3175 2 2
3 13 1871.68 27 14.29 2999 2 2
4 13 1060.08 27 14.45 1901 2 2
5 13 141.00 27 14.85 536 2 2
6 13 16.28 27 14.90 316 2 2
7 8 -0.20 190 14.86 290 2 2

Cycle 145 GMT 6/10/2020 14: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 21 14.95 430 2 2
2 7 2007.44 43 14.38 3138 2 2
3 13 1876.56 27 14.29 2974 2 2
4 13 840.08 27 14.54 1601 2 2
5 13 130.44 27 14.87 506 2 2
6 13 33.36 27 14.90 340 2 2
7 8 -0.20 190 14.87 291 2 2

Cycle 144 GMT 26/ 9/2020 13:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 21 14.99 421 2 2
2 7 2004.00 43 14.40 3121 2 2
3 13 1559.64 27 14.36 2575 2 2
4 13 947.08 27 14.48 1736 2 2
5 13 145.32 27 14.84 532 2 2
6 13 78.60 27 14.86 414 2 2
7 8 -0.28 190 14.84 292 2 2

Cycle 143 GMT 16/ 9/2020 13:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 21 14.98 431 2 2
2 7 2003.24 43 14.38 3166 2 2
3 13 1729.88 27 14.32 2801 2 2
4 13 836.64 27 14.54 1594 2 2
5 13 121.64 27 14.87 492 2 2
6 8 -0.12 190 14.88 291 2 2

Cycle 142 GMT 6/ 9/2020 12:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 21 14.98 437 2 2
2 7 2004.40 43 14.40 3101 2 2
3 13 1595.92 27 14.35 2607 2 2
4 13 864.76 27 14.52 1617 2 2
5 13 127.32 27 14.86 501 2 2
6 8 -0.16 190 14.87 291 2 2

Cycle 141 GMT 27/ 8/2020 11:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 21 14.99 436 2 2
2 7 2005.20 44 14.38 3118 2 2
3 13 1586.92 27 14.35 2605 2 2
4 13 837.80 27 14.53 1593 2 2
5 13 110.72 27 14.87 475 2 2
6 8 -0.12 190 14.87 291 2 2

Cycle 140 GMT 17/ 8/2020 10:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 21 14.99 440 2 2
2 7 2005.72 43 14.39 3157 2 2
3 13 1872.16 27 14.30 2991 2 2
4 13 786.52 27 14.57 1516 2 2
5 13 105.84 27 14.88 467 2 2
6 8 -0.16 190 14.89 287 2 2

Cycle 139 GMT 7/ 8/2020 10:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 21 14.99 431 2 2
2 7 2004.72 43 14.39 3173 2 2
3 13 1454.32 27 14.39 2421 2 2
4 13 870.64 27 14.52 1653 2 2
5 13 121.28 27 14.86 498 2 2
6 8 -0.08 190 14.87 290 2 2

Cycle 138 GMT 28/ 7/2020 10:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 21 14.99 450 2 2
2 7 2003.72 43 14.39 3159 2 2
3 13 1874.56 27 14.31 2996 2 2
4 13 920.64 27 14.52 1697 2 2
5 13 165.72 27 14.85 564 2 2
6 8 -0.28 190 14.88 281 2 2

Cycle 137 GMT 18/ 7/2020 10: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 22 14.98 427 2 2
2 3 958.76 -1 15.40 0 2 2
3 7 2002.08 43 14.39 3128 2 2
4 13 1732.60 27 14.33 2812 2 2
5 13 843.68 27 14.54 1601 2 2
6 13 120.40 27 14.87 496 2 2
7 13 29.28 27 14.90 337 2 2
8 8 -0.20 190 14.87 286 2 2

Cycle 136 GMT 8/ 7/2020 9:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 22 15.00 442 2 2
2 7 2003.80 43 14.39 3149 2 2
3 13 1477.08 27 14.38 2456 2 2
4 13 888.96 27 14.51 1647 2 2
5 13 130.80 27 14.87 497 2 2
6 8 -0.04 190 14.88 282 2 2

Cycle 135 GMT 28/ 6/2020 9:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 22 15.00 419 2 2
2 7 2001.72 43 14.39 3139 2 2
3 13 1598.64 27 14.35 2621 2 2
4 13 876.68 27 14.52 1637 2 2
5 13 133.48 27 14.86 508 2 2
6 8 -0.28 190 14.88 282 2 2

Cycle 134 GMT 18/ 6/2020 8:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 22 14.98 431 2 2
2 7 2002.68 44 14.39 3156 2 2
3 13 1460.24 27 14.38 2450 2 2
4 13 889.04 27 14.51 1661 2 2
5 13 133.64 27 14.85 518 2 2
6 8 -0.08 190 14.87 284 2 2

Cycle 133 GMT 8/ 6/2020 7:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 22 14.96 428 2 2
2 7 2037.16 43 14.37 3193 2 2
3 13 1919.32 27 14.29 3019 2 2
4 13 1004.56 27 14.48 1810 2 2
5 13 218.60 27 14.82 648 2 2
6 13 45.28 27 14.89 350 2 2
7 8 -0.16 190 14.86 282 2 3

Cycle 132 GMT 29/ 5/2020 6:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 22 14.99 430 2 2
2 7 1814.36 43 14.47 2847 2 2
3 13 1686.48 27 14.39 2727 2 2
4 13 685.04 27 14.61 1375 2 2
5 13 117.80 27 14.87 471 2 2
6 8 -0.20 190 14.88 280 2 2

Cycle 131 GMT 19/ 5/2020 5:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 22 14.99 426 2 2
2 7 2005.08 43 14.40 3120 2 2
3 13 1594.52 27 14.35 2606 2 2
4 13 872.28 27 14.52 1636 2 2
5 13 131.36 27 14.86 508 2 2
6 13 31.84 27 14.90 329 2 2
7 8 -0.16 190 14.87 282 2 2

Cycle 130 GMT 9/ 5/2020 4:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 22 15.01 410 2 2
2 7 2003.32 43 14.39 3138 2 2
3 13 1591.80 27 14.36 2615 2 2
4 13 835.60 27 14.54 1584 2 2
5 13 115.56 27 14.87 472 2 2
6 8 -0.16 190 14.88 285 2 2

Cycle 129 GMT 29/ 4/2020 4:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 22 15.01 421 2 2
2 7 2005.84 43 14.39 3179 2 2
3 13 1605.44 27 14.35 2625 2 2
4 13 750.80 27 14.58 1464 2 2
5 13 92.00 27 14.90 434 2 2
6 8 -0.04 190 14.90 281 2 2

Cycle 128 GMT 19/ 4/2020 3:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 22 15.00 428 2 2
2 7 2007.68 43 14.40 3128 2 2
3 13 1734.12 27 14.34 2801 2 2
4 13 837.08 27 14.56 1583 2 2
5 13 124.60 27 14.88 488 2 2
6 8 -0.12 190 14.90 279 2 2

Cycle 127 GMT 9/ 4/2020 3: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 22 14.98 421 2 2
2 7 2003.56 43 14.40 3129 2 2
3 13 1483.64 27 14.38 2456 2 2
4 13 785.12 27 14.56 1524 2 2
5 13 166.00 27 14.84 561 2 2
6 8 -0.08 190 14.88 281 2 2

Cycle 126 GMT 30/ 3/2020 2:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 22 15.00 410 2 2
2 7 2002.92 43 14.39 3132 2 2
3 13 1459.28 27 14.39 2406 2 2
4 13 900.52 27 14.51 1666 2 2
5 13 133.24 27 14.86 495 2 2
6 13 27.16 27 14.90 315 2 2
7 8 -0.40 190 14.87 272 2 2

Cycle 125 GMT 20/ 3/2020 1:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 22 15.00 416 2 2
2 7 2002.52 43 14.40 3151 2 2
3 13 1600.12 27 14.36 2603 2 2
4 13 750.32 27 14.60 1455 2 2
5 13 156.04 27 14.87 531 2 2
6 13 32.32 27 14.91 330 2 2
7 8 -0.20 190 14.88 277 2 2

Cycle 124 GMT 10/ 3/2020 1:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 22 15.00 426 2 2
2 7 2004.32 44 14.40 3132 2 2
3 13 1737.80 27 14.33 2807 2 2
4 13 824.84 27 14.56 1563 2 2
5 13 117.24 27 14.89 474 2 2
6 13 27.48 27 14.92 324 2 2
7 8 -0.16 190 14.88 277 2 3

Cycle 123 GMT 29/ 2/2020 0:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 22 15.01 421 2 2
2 7 2005.96 43 14.39 3165 2 2
3 13 1603.32 27 14.36 2615 2 2
4 13 860.68 27 14.54 1612 2 2
5 13 127.60 27 14.88 486 2 2
6 13 26.04 27 14.91 323 2 2
7 8 -0.32 190 14.88 275 2 2

Cycle 122 GMT 19/ 2/2020 0:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 22 15.01 406 2 2
2 7 2002.60 43 14.39 3148 2 2
3 13 1870.08 27 14.31 2989 2 2
4 13 829.72 27 14.56 1581 2 2
5 13 128.60 27 14.89 496 2 2
6 13 28.52 27 14.92 326 2 2
7 8 -0.24 190 14.89 278 2 2

Cycle 121 GMT 8/ 2/2020 23:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 22 15.00 416 2 2
2 7 2001.84 44 14.40 3124 2 2
3 13 1713.52 27 14.34 2774 2 2
4 13 821.36 27 14.56 1566 2 2
5 13 120.08 27 14.89 474 2 2
6 13 30.24 27 14.92 316 2 2
7 8 -0.28 190 14.89 271 2 2

Cycle 120 GMT 29/ 1/2020 23:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 22 14.99 428 2 2
2 7 2002.96 43 14.40 3151 2 2
3 13 1454.32 27 14.40 2422 2 2
4 13 737.72 27 14.59 1444 2 2
5 13 142.64 27 14.87 512 2 2
6 13 31.08 27 14.91 327 2 2
7 8 -0.16 190 14.88 277 2 2

Cycle 119 GMT 19/ 1/2020 22:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 22 15.01 414 2 2
2 7 2006.88 43 14.40 3149 2 2
3 13 1602.68 27 14.37 2619 2 2
4 13 857.96 27 14.54 1607 2 2
5 13 217.68 27 14.83 636 2 2
6 13 40.92 27 14.90 340 2 2
7 8 -0.32 190 14.87 280 2 2

Cycle 118 GMT 9/ 1/2020 22:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 22 15.02 414 2 2
2 7 2002.80 43 14.40 3142 2 2
3 13 1723.56 27 14.35 2805 2 2
4 13 945.52 27 14.51 1720 2 2
5 13 186.56 27 14.86 578 2 2
6 13 21.72 27 14.93 302 2 2
7 8 -0.20 190 14.89 268 2 2

Cycle 117 GMT 30/12/2019 21:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 22 15.01 420 2 2
2 7 2002.28 43 14.41 3098 2 2
3 13 1595.60 27 14.36 2623 2 2
4 13 873.88 27 14.54 1645 2 2
5 13 137.92 27 14.88 507 2 2
6 13 33.04 27 14.92 330 2 2
7 8 -0.36 190 14.88 275 2 2

Cycle 116 GMT 20/12/2019 21: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 22 15.01 423 2 2
2 7 2005.72 43 14.41 3096 2 2
3 13 1485.92 27 14.39 2489 2 2
4 13 779.72 27 14.59 1502 2 2
5 13 165.92 27 14.86 550 2 2
6 8 -0.16 190 14.90 273 2 2

Cycle 115 GMT 10/12/2019 20:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 22 15.01 417 2 2
2 7 2001.96 43 14.41 3145 2 2
3 13 1592.88 27 14.38 2570 2 2
4 13 857.44 27 14.55 1611 2 2
5 13 132.40 27 14.89 492 2 2
6 13 15.36 27 14.93 297 2 2
7 8 -0.32 190 14.89 269 2 2

Cycle 114 GMT 30/11/2019 19:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 22 15.01 414 2 2
2 7 2003.00 43 14.41 3147 2 2
3 13 1586.92 27 14.38 2593 2 2
4 13 854.28 27 14.55 1611 2 2
5 13 130.32 27 14.89 488 2 2
6 8 -0.12 190 14.90 271 2 2

Cycle 113 GMT 20/11/2019 19:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 22 15.01 416 2 2
2 7 2003.92 43 14.41 3135 2 2
3 13 1592.24 27 14.38 2613 2 2
4 13 737.40 27 14.61 1438 2 2
5 13 148.00 27 14.88 518 2 2
6 13 32.56 27 14.93 332 2 2
7 8 -0.20 190 14.89 272 2 2

Cycle 112 GMT 10/11/2019 18:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 22 15.02 447 2 2
2 7 2001.96 43 14.40 3154 2 2
3 13 1587.64 27 14.38 2578 2 2
4 13 851.16 27 14.56 1610 2 2
5 13 133.64 27 14.89 501 2 2
6 13 31.64 27 14.93 330 2 2
7 8 -0.24 190 14.89 276 2 2

Cycle 111 GMT 31/10/2019 18: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 21 15.01 442 2 2
2 3 1043.24 1 15.06 1892 2 2
3 7 2004.92 43 14.41 3145 2 2
4 13 1595.84 27 14.39 2607 2 2
5 13 835.48 27 14.57 1584 2 2
6 13 130.44 27 14.90 493 2 2
7 8 -0.08 190 14.91 278 2 2

Cycle 110 GMT 21/10/2019 17:30: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 21 15.01 422 2 2
2 7 2003.60 44 14.42 3106 2 2
3 13 1449.76 27 14.42 2410 2 2
4 13 726.48 27 14.61 1428 2 2
5 13 143.00 27 14.88 515 2 2
6 8 -0.16 190 14.90 279 2 2

Cycle 109 GMT 11/10/2019 17: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 21 15.02 427 2 2
2 7 2009.40 43 14.42 3151 2 2
3 13 1607.00 27 14.38 2633 2 2
4 13 734.28 27 14.62 1442 2 2
5 13 143.16 27 14.89 509 2 2
6 8 -0.12 190 14.91 283 2 2

Cycle 108 GMT 1/10/2019 16: 3:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 21 15.02 425 2 2
2 7 2003.72 43 14.42 3125 2 2
3 13 1737.68 27 14.37 2757 2 2
4 13 846.16 27 14.57 1603 2 2
5 13 122.64 27 14.90 491 2 2
6 8 -0.20 190 14.91 280 2 2

Cycle 107 GMT 21/ 9/2019 15:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 21 15.01 447 2 2
2 3 1025.40 1 15.13 1858 2 2
3 7 2002.64 43 14.42 3165 2 2
4 13 1723.76 27 14.37 2792 2 2
5 13 830.52 27 14.59 1574 2 2
6 13 129.76 27 14.91 500 2 2
7 13 26.56 27 14.95 322 2 2
8 8 -0.12 190 14.91 279 2 2

Cycle 106 GMT 11/ 9/2019 14:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 21 15.00 427 2 2
2 7 2014.84 44 14.41 3153 2 2
3 13 1880.04 27 14.33 3003 2 2
4 13 1067.08 27 14.49 1900 2 2
5 13 139.04 27 14.90 522 2 2
6 8 -0.04 190 14.92 284 2 2

Cycle 105 GMT 1/ 9/2019 14:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 21 15.01 424 2 2
2 7 2001.24 43 14.42 3146 2 2
3 13 1470.80 27 14.42 2450 2 2
4 13 740.12 27 14.62 1460 2 2
5 13 138.56 27 14.89 518 2 2
6 8 -0.16 190 14.90 284 2 2

Cycle 104 GMT 22/ 8/2019 13:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 21 15.02 430 2 2
2 7 2005.80 43 14.43 3128 2 2
3 13 1605.56 27 14.39 2620 2 2
4 13 894.68 27 14.56 1669 2 2
5 13 126.24 27 14.90 491 2 2
6 8 -0.16 190 14.91 279 2 2

Cycle 103 GMT 12/ 8/2019 13: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 21 15.02 454 2 2
2 7 2004.36 43 14.42 3151 2 2
3 13 1726.64 27 14.38 2707 2 2
4 13 840.68 27 14.59 1606 2 2
5 13 126.76 27 14.91 497 2 2
6 8 -0.12 190 14.92 283 2 2

Cycle 102 GMT 2/ 8/2019 12:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 21 15.02 432 2 2
2 7 2002.28 43 14.43 3135 2 2
3 13 1466.20 27 14.43 2449 2 2
4 13 881.96 27 14.56 1661 2 2
5 13 130.20 27 14.90 501 2 2
6 8 -0.08 190 14.91 281 2 2

Cycle 101 GMT 23/ 7/2019 11:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 21 15.01 423 2 2
2 7 2001.52 43 14.43 3143 2 2
3 13 1728.56 27 14.39 2763 2 2
4 13 946.76 27 14.55 1742 2 2
5 13 172.80 27 14.89 567 2 2
6 8 -0.24 190 14.92 284 2 2

Cycle 100 GMT 13/ 7/2019 11:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 21 15.02 430 2 2
2 7 2007.60 43 14.43 3133 2 2
3 13 1466.32 27 14.44 2414 2 2
4 13 752.92 27 14.62 1483 2 2
5 13 136.08 27 14.89 517 2 2
6 8 -0.12 190 14.91 287 2 2

Cycle 99 GMT 3/ 7/2019 11: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 21 14.92 444 2 2
2 3 970.96 -1 15.43 0 2 2
3 7 2003.80 43 14.43 3164 2 2
4 13 1587.72 27 14.41 2589 2 2
5 13 840.96 27 14.60 1594 2 2
6 13 119.12 27 14.92 483 2 2
7 8 0.08 190 14.92 286 2 2

Cycle 98 GMT 23/ 6/2019 10:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 21 14.94 439 2 2
2 3 1019.00 1 15.14 1875 2 2
3 7 2003.20 43 14.44 3143 2 2
4 13 1483.64 27 14.43 2454 2 2
5 13 766.12 27 14.62 1493 2 2
6 13 144.72 27 14.89 535 2 2
7 8 -0.12 170 14.91 286 2 2

Cycle 97 GMT 13/ 6/2019 10:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 21 14.95 428 2 2
2 7 2001.36 44 14.44 3098 2 2
3 13 1733.44 27 14.38 2783 2 2
4 13 686.08 27 14.68 1375 2 2
5 13 124.16 27 14.92 502 2 2
6 8 0.12 170 14.94 286 2 2

Cycle 96 GMT 3/ 6/2019 10:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 21 14.95 427 2 2
2 7 2007.48 43 14.44 3109 2 2
3 13 1875.84 27 14.35 3015 2 2
4 13 795.44 27 14.63 1528 2 2
5 13 102.56 27 14.94 459 2 2
6 8 0.00 170 14.94 281 2 2

Cycle 95 GMT 24/ 5/2019 10: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 21 14.92 418 2 2
2 7 2004.68 43 14.43 3179 2 2
3 13 1463.24 27 14.45 2419 2 2
4 13 882.96 27 14.58 1655 2 2
5 13 137.20 27 14.91 509 2 2
6 8 0.28 170 14.93 278 2 2

Cycle 94 GMT 14/ 5/2019 9:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 21 14.92 444 2 2
2 7 2006.64 43 14.44 3098 2 2
3 13 1471.76 27 14.45 2428 2 2
4 13 754.08 27 14.64 1484 2 2
5 13 96.32 27 14.93 459 2 2
6 13 51.44 27 14.93 376 2 2
7 8 -0.08 170 14.91 287 2 2

Cycle 93 GMT 4/ 5/2019 9:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 21 14.93 440 2 2
2 7 2007.16 44 14.42 3143 2 2
3 13 1581.60 27 14.42 2574 2 2
4 13 822.40 27 14.61 1576 2 2
5 13 178.96 27 14.88 590 2 2
6 13 34.72 27 14.94 341 2 2
7 8 -0.08 170 14.91 286 2 2

Cycle 92 GMT 24/ 4/2019 9:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 21 14.93 435 2 2
2 7 2002.16 43 14.43 3150 2 2
3 13 1730.12 27 14.39 2795 2 2
4 13 732.56 27 14.66 1445 2 2
5 13 138.56 27 14.92 521 2 2
6 13 30.40 27 14.95 335 2 2
7 8 -0.04 170 14.93 277 2 2

Cycle 91 GMT 14/ 4/2019 9:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 22 14.94 423 2 2
2 3 971.68 -1 15.44 0 2 2
3 7 2011.68 43 14.42 3136 2 2
4 13 1737.96 27 14.40 2672 2 2
5 13 960.44 27 14.56 1742 2 2
6 13 159.68 27 14.90 547 2 2
7 13 17.32 27 14.96 300 2 2
8 8 0.00 170 14.92 274 2 2

Cycle 90 GMT 4/ 4/2019 8:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 21 14.96 433 2 2
2 3 1033.24 1 15.12 1871 2 2
3 7 2004.76 43 14.43 3143 2 2
4 13 1723.64 27 14.39 2783 2 2
5 13 697.56 27 14.68 1385 2 2
6 13 126.00 27 14.93 494 2 2
7 13 30.64 27 14.96 330 2 2
8 8 0.00 170 14.93 274 2 2

Cycle 89 GMT 25/ 3/2019 8:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 21 14.94 436 2 2
2 7 2006.08 43 14.43 3171 2 2
3 13 1586.44 27 14.42 2596 2 2
4 13 827.80 27 14.62 1568 2 2
5 13 126.60 27 14.93 485 2 2
6 13 30.28 27 14.97 326 2 2
7 8 0.00 170 14.93 277 2 2

Cycle 88 GMT 15/ 3/2019 8:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 21 14.95 419 2 2
2 7 2005.24 43 14.43 3146 2 2
3 13 1592.84 27 14.42 2626 2 2
4 13 737.72 27 14.66 1449 2 2
5 13 133.08 27 14.92 512 2 2
6 13 35.68 27 14.96 342 2 2
7 8 -0.08 170 14.92 281 2 2

Cycle 87 GMT 5/ 3/2019 7:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 21 14.93 425 2 2
2 7 2003.16 44 14.44 3115 2 2
3 13 1586.60 27 14.43 2576 2 2
4 13 723.44 27 14.67 1425 2 2
5 13 134.84 27 14.93 507 2 2
6 13 14.88 27 14.97 297 2 2
7 8 0.00 170 14.93 279 2 3

Cycle 86 GMT 23/ 2/2019 7:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 21 14.95 425 2 2
2 7 2003.08 43 14.44 3132 2 2
3 13 1581.28 27 14.43 2581 2 2
4 13 843.44 27 14.62 1586 2 2
5 13 104.96 27 14.94 453 2 2
6 13 25.24 27 14.96 316 2 2
7 8 -0.16 170 14.92 280 2 2

Cycle 85 GMT 13/ 2/2019 7:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 21 14.95 418 2 2
2 7 2004.36 43 14.43 3128 2 2
3 13 1737.36 27 14.39 2814 2 2
4 13 797.80 27 14.64 1532 2 2
5 13 115.84 27 14.95 468 2 2
6 13 13.96 27 14.98 299 2 2
7 8 0.08 170 14.94 277 2 2

Cycle 84 GMT 3/ 2/2019 7:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 21 14.96 420 2 2
2 7 2004.64 43 14.43 3153 2 2
3 13 1561.56 27 14.44 2570 2 2
4 13 685.32 27 14.69 1363 2 2
5 13 115.56 27 14.94 470 2 2
6 13 32.52 27 14.97 330 2 2
7 8 -0.16 170 14.94 272 2 2

Cycle 83 GMT 24/ 1/2019 7:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 20 14.94 425 2 2
2 7 2007.68 43 14.43 3133 2 2
3 13 1873.64 27 14.36 2964 2 2
4 13 681.68 27 14.71 1358 2 2
5 13 124.84 27 14.95 482 2 2
6 13 30.04 27 14.98 324 2 2
7 8 0.04 170 14.95 275 2 2

Cycle 82 GMT 14/ 1/2019 7:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 21 14.94 427 2 2
2 7 2003.00 43 14.44 3150 2 2
3 13 1584.00 27 14.43 2589 2 2
4 13 700.16 27 14.68 1390 2 2
5 13 126.76 27 14.93 497 2 2
6 13 12.84 27 14.97 301 2 2
7 8 -0.04 170 14.93 282 2 2

Cycle 81 GMT 4/ 1/2019 7:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 21 14.95 409 2 2
2 7 2006.24 44 14.43 3129 2 2
3 13 1578.96 27 14.44 2561 2 2
4 13 954.92 27 14.57 1738 2 2
5 13 138.40 27 14.92 510 2 2
6 13 28.80 27 14.96 330 2 2
7 8 0.00 170 14.93 280 2 2

Cycle 80 GMT 25/12/2018 7:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 21 14.96 424 2 2
2 7 2002.40 43 14.44 3172 2 2
3 13 1579.12 27 14.44 2592 2 2
4 13 814.60 27 14.64 1564 2 2
5 13 108.36 27 14.95 463 2 2
6 13 25.52 27 14.97 326 2 2
7 8 -0.04 170 14.94 280 2 2

Cycle 79 GMT 15/12/2018 7:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 21 14.95 442 2 2
2 7 2001.88 43 14.45 3125 2 2
3 13 1735.52 26 14.40 2819 2 2
4 13 711.80 26 14.70 1400 2 2
5 13 141.96 26 14.95 508 2 2
6 13 30.36 26 14.99 319 2 2
7 8 -0.04 170 14.96 274 2 2

Cycle 78 GMT 5/12/2018 7:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 21 14.95 443 2 2
2 7 2002.68 43 14.45 3109 2 2
3 13 1554.96 26 14.44 2558 2 2
4 13 817.16 26 14.63 1561 2 2
5 13 123.36 26 14.95 486 2 2
6 13 15.00 26 14.99 303 2 2
7 8 -0.12 170 14.95 277 2 2

Cycle 77 GMT 25/11/2018 6:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 21 14.99 432 2 2
2 7 2005.92 43 14.44 3126 2 2
3 13 1592.48 26 14.43 2600 2 2
4 13 977.20 26 14.57 1773 2 2
5 13 211.96 26 14.90 641 2 2
6 13 21.16 26 14.98 317 2 2
7 8 -0.16 170 14.95 280 2 2

Cycle 76 GMT 15/11/2018 6:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 21 14.96 435 2 2
2 7 2009.44 43 14.45 3140 2 2
3 13 1882.92 26 14.37 2982 2 2
4 13 839.72 26 14.65 1591 2 2
5 13 138.04 26 14.96 509 2 2
6 8 0.08 170 14.98 278 2 2

Cycle 75 GMT 5/11/2018 6: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 20 14.99 434 2 2
2 3 1045.44 1 15.11 1882 2 2
3 7 2003.80 44 14.45 3109 2 2
4 13 1594.04 26 14.44 2591 2 2
5 13 727.16 26 14.69 1429 2 2
6 13 138.28 26 14.94 522 2 2
7 8 -0.04 170 14.96 279 2 2

Cycle 74 GMT 26/10/2018 5:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 21 14.97 431 2 2
2 7 2020.32 43 14.43 3171 2 2
3 13 1897.20 26 14.36 3019 2 2
4 13 818.28 26 14.65 1571 2 2
5 13 129.56 26 14.96 502 2 2
6 8 0.00 170 14.98 278 2 2

Cycle 73 GMT 16/10/2018 5: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 20 14.97 442 2 2
2 7 2004.16 43 14.46 3105 2 2
3 13 1594.48 26 14.44 2605 2 2
4 13 702.24 26 14.70 1391 2 2
5 13 148.16 26 14.95 527 2 2
6 8 0.08 170 14.97 276 2 2

Cycle 72 GMT 6/10/2018 4:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 20 14.97 429 2 2
2 7 2010.44 43 14.45 3169 2 2
3 13 1482.76 26 14.47 2452 2 2
4 13 890.16 26 14.62 1649 2 2
5 13 146.04 26 14.95 516 2 2
6 13 73.48 26 14.97 392 2 2
7 8 -0.16 170 14.96 271 2 2

Cycle 71 GMT 26/ 9/2018 4:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 20 14.98 435 2 2
2 7 2002.84 44 14.45 3096 2 2
3 13 1575.84 26 14.45 2566 2 2
4 13 965.88 26 14.59 1752 2 2
5 13 166.44 26 14.93 556 2 2
6 8 0.08 170 14.97 272 2 2

Cycle 70 GMT 16/ 9/2018 4:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 20 14.98 424 2 2
2 7 2005.84 43 14.46 3125 2 2
3 13 1466.48 26 14.48 2432 2 2
4 13 610.48 26 14.75 1258 2 2
5 13 104.08 26 14.97 462 2 2
6 8 -0.04 170 14.98 281 2 2

Cycle 69 GMT 6/ 9/2018 4:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 20 14.98 418 2 2
2 7 2003.20 43 14.46 3124 2 2
3 13 1450.16 26 14.49 2427 2 2
4 13 862.96 26 14.64 1621 2 2
5 13 136.52 26 14.96 510 2 2
6 8 0.08 170 14.97 278 2 2

Cycle 68 GMT 27/ 8/2018 4:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 20 14.96 443 2 2
2 7 2003.12 43 14.48 3111 2 2
3 13 1616.16 26 14.45 2633 2 2
4 13 753.48 26 14.70 1464 2 2
5 13 156.92 26 14.96 539 2 2
6 13 21.88 26 15.01 310 2 2
7 8 0.12 170 14.97 274 2 2

Cycle 67 GMT 17/ 8/2018 4: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 21 14.97 422 2 2
2 7 2001.20 44 14.47 3120 2 2
3 13 1422.88 26 14.50 2362 2 2
4 13 707.24 26 14.72 1387 2 2
5 13 119.64 26 14.97 481 2 2
6 13 29.60 26 15.00 331 2 2
7 8 0.04 170 14.96 282 2 2

Cycle 66 GMT 7/ 8/2018 3:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 20 14.98 440 2 2
2 10 1004.48 3 15.03 1809 2 2
3 3 947.36 -1 15.46 0 2 2
4 7 2009.04 43 14.47 3132 2 2
5 13 1596.12 26 14.46 2603 2 2
6 13 738.96 26 14.70 1460 2 2
7 13 142.84 26 14.96 531 2 2
8 13 34.64 26 14.99 345 2 2
9 8 -0.08 170 14.97 282 2 2

Cycle 65 GMT 28/ 7/2018 2:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 20 14.98 418 2 2
2 7 2001.20 44 14.46 3169 2 2
3 13 1460.80 26 14.50 2436 2 2
4 13 882.68 26 14.65 1646 2 2
5 13 121.56 26 14.97 491 2 2
6 8 0.00 170 14.98 281 2 2

Cycle 64 GMT 18/ 7/2018 2:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 20 15.02 406 2 2
2 7 2005.40 43 14.49 3126 2 2
3 13 1464.28 26 14.51 2426 2 2
4 13 760.60 26 14.71 1480 2 2
5 13 145.80 26 14.97 534 2 2
6 8 0.04 170 14.99 277 2 2

Cycle 63 GMT 8/ 7/2018 1:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 20 15.00 430 2 2
2 7 2002.40 43 14.48 3151 2 2
3 13 1867.80 26 14.41 3006 2 2
4 13 768.24 26 14.73 1488 2 2
5 13 92.24 26 15.02 443 2 2
6 8 0.04 170 15.01 280 2 2

Cycle 62 GMT 28/ 6/2018 1:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 20 15.01 418 2 2
2 7 2003.24 43 14.48 3147 2 2
3 13 1596.44 26 14.48 2599 2 2
4 13 856.60 26 14.68 1612 2 2
5 13 113.60 26 14.99 476 2 2
6 8 -0.12 170 15.00 281 2 2

Cycle 61 GMT 18/ 6/2018 1:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 20 15.01 421 2 2
2 7 2004.64 43 14.49 3141 2 2
3 13 1476.64 26 14.52 2439 2 2
4 13 889.36 26 14.66 1664 2 2
5 13 129.80 26 14.99 506 2 2
6 8 0.08 170 15.01 276 2 2

Cycle 60 GMT 8/ 6/2018 0:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 20 15.02 427 2 2
2 7 2002.76 43 14.50 3147 2 2
3 13 1735.56 26 14.46 2818 2 2
4 13 676.04 26 14.77 1372 2 2
5 13 122.32 26 15.01 494 2 2
6 13 29.96 26 15.04 332 2 2
7 8 0.00 170 15.00 277 2 2

Cycle 59 GMT 29/ 5/2018 0:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 20 15.01 434 2 2
2 7 2001.32 44 14.49 3160 2 2
3 13 1716.48 26 14.45 2782 2 2
4 13 922.16 26 14.66 1705 2 2
5 13 89.20 26 15.03 440 2 2
6 13 46.84 26 15.03 363 2 2
7 8 -0.04 170 15.01 279 2 2

Cycle 58 GMT 19/ 5/2018 0: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 20 15.02 434 2 2
2 7 2004.68 43 14.50 3144 2 2
3 13 1583.08 26 14.50 2606 2 2
4 13 705.72 26 14.77 1415 2 2
5 13 130.96 26 15.01 509 2 2
6 13 27.12 26 15.05 323 2 2
7 8 -0.04 170 15.01 279 2 2

Cycle 57 GMT 8/ 5/2018 23:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 20 15.03 421 2 2
2 7 2002.96 43 14.50 3148 2 2
3 13 1595.44 26 14.50 2647 2 2
4 13 727.48 26 14.77 1433 2 2
5 13 131.60 26 15.01 513 2 2
6 13 29.72 26 15.04 333 2 2
7 8 -0.04 170 15.01 278 2 2

Cycle 56 GMT 28/ 4/2018 23:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 20 15.02 434 2 2
2 7 2009.12 44 14.50 3140 2 2
3 13 1457.92 26 14.55 2427 2 2
4 13 603.64 26 14.82 1253 2 2
5 13 76.32 26 15.04 415 2 2
6 13 42.56 26 15.04 358 2 2
7 8 -0.08 170 15.02 278 2 2

Cycle 55 GMT 18/ 4/2018 22:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 20 15.03 432 2 2
2 7 2007.20 44 14.50 3150 2 2
3 13 1462.52 26 14.56 2415 2 2
4 13 747.52 26 14.76 1470 2 2
5 13 75.76 26 15.05 421 2 2
6 13 39.76 26 15.05 351 2 2
7 8 -0.08 170 15.02 282 2 2

Cycle 54 GMT 8/ 4/2018 21:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 20 15.04 437 2 2
2 7 2004.00 43 14.51 3156 2 2
3 13 1470.56 26 14.55 2462 2 2
4 13 768.40 26 14.75 1509 2 2
5 13 83.36 26 15.04 443 2 2
6 13 23.28 26 15.06 332 2 2
7 8 -0.08 170 15.02 280 2 2

Cycle 53 GMT 29/ 3/2018 20:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 20 15.06 413 2 2
2 7 2001.76 44 14.51 3156 2 2
3 13 1449.56 26 14.56 2402 2 2
4 13 736.08 26 14.77 1463 2 2
5 13 137.72 26 15.02 523 2 2
6 8 0.00 170 15.04 280 2 2

Cycle 52 GMT 19/ 3/2018 20:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 20 15.05 416 2 2
2 7 2004.72 43 14.52 3137 2 2
3 13 1603.52 26 14.52 2638 2 2
4 13 741.56 26 14.79 1462 2 2
5 13 144.00 26 15.04 526 2 2
6 13 17.52 26 15.09 306 2 2
7 8 0.04 170 15.05 269 2 2

Cycle 51 GMT 9/ 3/2018 19:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 20 15.07 422 2 2
2 7 2004.56 43 14.51 3142 2 2
3 13 1873.40 26 14.46 3002 2 2
4 13 938.04 26 14.72 1731 2 2
5 13 183.52 26 15.03 595 2 2
6 13 43.76 26 15.08 358 2 2
7 8 0.04 170 15.05 280 2 2

Cycle 50 GMT 27/ 2/2018 19:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 20 15.07 419 2 2
2 3 1027.32 1 15.19 1868 2 2
3 7 2002.48 43 14.52 3184 2 2
4 13 1592.76 26 14.54 2613 2 2
5 13 702.64 26 14.81 1416 2 2
6 13 127.48 26 15.06 506 2 2
7 13 33.92 26 15.08 342 2 2
8 8 -0.04 170 15.06 275 2 2

Cycle 49 GMT 17/ 2/2018 18:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 20 15.07 428 2 2
2 7 2000.52 43 14.53 3125 2 2
3 13 1578.28 26 14.56 2565 2 2
4 13 849.04 26 14.75 1609 2 2
5 13 118.28 26 15.06 492 2 2
6 13 59.56 26 15.07 386 2 2
7 8 -0.04 170 15.06 274 2 2

Cycle 48 GMT 7/ 2/2018 17:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 20 15.08 414 2 2
2 7 2004.72 43 14.53 3131 2 2
3 13 1592.88 26 14.55 2589 2 2
4 13 850.68 26 14.77 1598 2 2
5 13 113.84 26 15.07 475 2 2
6 13 31.16 26 15.10 329 2 2
7 8 0.04 170 15.07 274 2 2

Cycle 47 GMT 28/ 1/2018 17:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 20 15.08 404 2 2
2 7 2003.68 43 14.53 3163 2 2
3 13 1463.32 26 14.60 2443 2 2
4 13 708.12 26 14.83 1403 2 2
5 13 129.08 26 15.07 503 2 2
6 13 30.56 26 15.10 330 2 2
7 8 -0.12 170 15.07 275 2 2

Cycle 46 GMT 18/ 1/2018 16:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 20 15.08 435 2 2
2 7 2003.76 43 14.53 3164 2 2
3 13 1739.44 26 14.52 2791 2 2
4 13 852.44 26 14.78 1637 2 2
5 13 125.80 26 15.08 503 2 2
6 13 34.68 26 15.11 341 2 2
7 8 -0.08 170 15.08 281 2 2

Cycle 45 GMT 8/ 1/2018 15:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 20 15.09 421 2 2
2 7 2008.84 43 14.54 3167 2 2
3 13 1468.68 26 14.61 2456 2 2
4 13 744.24 26 14.82 1490 2 2
5 13 146.60 26 15.07 542 2 2
6 13 15.92 26 15.12 313 2 2
7 8 0.00 170 15.07 287 2 2

Cycle 44 GMT 29/12/2017 14:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 20 15.10 434 2 2
2 7 2001.68 43 14.54 3148 2 2
3 13 1719.56 26 14.54 2741 2 2
4 13 800.84 26 14.81 1553 2 2
5 13 171.16 26 15.07 586 2 2
6 13 37.20 26 15.11 346 2 2
7 8 -0.16 170 15.08 279 2 2

Cycle 43 GMT 19/12/2017 14:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 20 15.11 424 2 2
2 7 2007.92 44 14.54 3168 2 2
3 13 1456.92 26 14.62 2420 2 2
4 13 1011.40 26 14.72 1841 2 2
5 13 119.56 26 15.10 487 2 2
6 13 27.72 26 15.13 340 2 2
7 8 0.08 170 15.10 278 2 2

Cycle 42 GMT 9/12/2017 14:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 20 15.10 432 2 2
2 7 2003.48 43 14.55 3178 2 2
3 13 1586.44 26 14.58 2608 2 2
4 13 849.00 26 14.80 1628 2 2
5 13 125.48 26 15.10 514 2 2
6 8 0.08 170 15.11 283 2 2

Cycle 41 GMT 29/11/2017 13:26:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 20 15.12 449 2 2
2 7 2002.32 44 14.56 3140 2 2
3 13 1582.28 26 14.59 2596 2 2
4 13 800.12 26 14.82 1550 2 2
5 13 158.08 26 15.08 568 2 2
6 8 -0.04 170 15.11 286 2 2

Cycle 40 GMT 19/11/2017 13: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 19 15.13 429 2 2
2 7 2001.32 43 14.57 3127 2 2
3 13 1465.36 26 14.64 2444 2 2
4 13 760.68 26 14.85 1494 2 2
5 13 152.36 26 15.09 559 2 2
6 8 0.04 170 15.12 279 2 2

Cycle 39 GMT 9/11/2017 12:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 19 15.12 447 2 2
2 7 2004.00 43 14.56 3186 2 2
3 13 1871.12 26 14.52 2978 2 2
4 13 812.72 26 14.84 1561 2 2
5 13 133.00 26 15.12 506 2 2
6 8 0.08 170 15.13 282 2 2

Cycle 38 GMT 30/10/2017 11:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 19 15.13 426 2 2
2 7 1995.28 43 14.57 3128 2 2
3 13 1716.40 26 14.58 2771 2 2
4 13 815.76 26 14.84 1571 2 2
5 13 176.12 26 15.09 599 2 2
6 8 -0.04 170 15.12 292 2 2

Cycle 37 GMT 20/10/2017 10:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 19 15.13 427 2 2
2 7 2002.96 39 14.60 3154 2 2
3 13 1871.36 29 14.53 2992 2 2
4 13 788.40 29 14.85 1527 2 2
5 13 165.72 29 15.10 582 2 2
6 8 -0.08 170 15.12 288 2 2

Cycle 36 GMT 10/10/2017 10:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 19 15.14 431 2 2
2 7 2006.76 40 14.60 3147 2 2
3 13 1891.40 29 14.53 3046 2 2
4 13 792.20 29 14.85 1545 2 2
5 13 101.88 29 15.14 464 2 2
6 8 0.04 170 15.13 283 2 2

Cycle 35 GMT 30/ 9/2017 10:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 20 15.13 429 2 2
2 3 970.40 -1 15.53 0 2 2
3 7 1990.68 39 14.62 3100 2 2
4 13 1726.84 29 14.59 2786 2 2
5 13 959.04 29 14.79 1769 2 2
6 13 103.04 29 15.14 466 2 2
7 8 0.00 170 15.14 282 2 2

Cycle 34 GMT 20/ 9/2017 9:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 20 15.14 469 2 2
2 7 2007.96 40 14.59 3175 2 2
3 13 1594.16 29 14.63 2603 2 2
4 13 808.12 29 14.85 1553 2 2
5 13 147.40 29 15.12 547 2 2
6 8 -0.12 170 15.13 287 2 2

Cycle 33 GMT 10/ 9/2017 9: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 20 15.15 440 2 2
2 7 2003.52 39 14.63 3086 2 2
3 13 1603.84 29 14.63 2620 2 2
4 13 852.88 29 14.84 1618 2 2
5 13 114.88 29 15.14 490 2 2
6 8 0.04 170 15.14 286 2 2

Cycle 32 GMT 31/ 8/2017 8:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 18 15.16 442 2 2
2 3 1060.40 2 15.16 1935 2 2
3 3 1018.96 1 15.27 1896 2 2
4 7 2002.32 39 14.64 3074 2 2
5 13 1735.92 29 14.60 2813 2 2
6 13 813.72 29 14.87 1548 2 2
7 13 110.36 29 15.15 469 2 2
8 8 0.04 170 15.15 282 2 2

Cycle 31 GMT 21/ 8/2017 7:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 19 15.14 433 2 2
2 3 966.00 -1 15.54 0 2 2
3 7 2001.16 39 14.64 3063 2 2
4 13 1735.60 29 14.62 2723 2 2
5 13 981.56 29 14.80 1794 2 2
6 13 110.52 29 15.15 482 2 2
7 8 0.00 170 15.16 284 2 2

Cycle 30 GMT 11/ 8/2017 6:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 19 15.17 423 2 2
2 7 2003.68 39 14.63 3122 2 2
3 13 1601.88 29 14.65 2614 2 2
4 13 722.72 29 14.90 1438 2 2
5 13 117.44 29 15.14 502 2 2
6 8 0.04 170 15.15 293 2 2

Cycle 29 GMT 1/ 8/2017 6: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 19 15.17 415 2 2
2 7 2002.64 40 14.61 3146 2 2
3 13 1735.80 29 14.61 2782 2 2
4 13 791.04 29 14.88 1512 2 2
5 13 72.40 29 15.18 402 2 2
6 8 -0.16 190 15.16 279 2 2

Cycle 28 GMT 22/ 7/2017 4:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 20 15.18 430 2 2
2 7 2008.40 39 14.63 3152 2 2
3 13 1615.12 29 14.65 2613 2 2
4 13 723.80 29 14.92 1430 2 2
5 13 123.60 29 15.16 491 2 2
6 8 -0.08 190 15.16 275 2 2

Cycle 27 GMT 12/ 7/2017 4: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 19 15.18 427 2 2
2 7 2002.32 39 14.65 3102 2 2
3 13 1868.64 29 14.58 3018 2 2
4 13 911.44 29 14.85 1695 2 2
5 13 126.72 29 15.16 526 2 2
6 8 -0.12 190 15.16 298 2 2

Cycle 26 GMT 2/ 7/2017 3:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 19 15.18 466 2 2
2 3 1022.24 1 15.29 1856 2 2
3 7 2000.76 39 14.64 3112 2 2
4 13 1606.16 29 14.66 2639 2 2
5 13 1128.44 29 14.75 1990 2 2
6 13 83.00 29 15.18 442 2 2
7 8 -0.08 190 15.16 295 2 2

Cycle 25 GMT 22/ 6/2017 2:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 19 15.18 419 2 2
2 3 971.00 -1 15.58 0 2 2
3 7 2011.64 40 14.63 3158 2 2
4 13 1880.08 29 14.58 3000 2 2
5 13 915.08 29 14.85 1702 2 2
6 13 125.12 29 15.16 517 2 2
7 8 0.12 190 15.16 296 2 2

Cycle 24 GMT 12/ 6/2017 1:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 19 15.20 400 2 2
2 10 1003.40 3 15.18 1764 2 2
3 3 915.68 -2 15.56 0 2 2
4 7 2002.00 39 14.65 3132 2 2
5 13 1727.48 29 14.63 2794 2 2
6 13 813.00 29 14.89 1576 2 2
7 13 97.52 29 15.18 476 2 2
8 13 24.16 29 15.19 334 2 2
9 8 -0.16 190 15.16 273 2 2

Cycle 23 GMT 2/ 6/2017 0:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 19 15.21 389 2 2
2 7 2002.32 39 14.65 3155 2 2
3 13 1467.96 29 14.72 2416 2 2
4 13 867.60 29 14.88 1608 2 2
5 13 111.64 29 15.18 476 2 2
6 8 -0.04 190 15.18 273 2 2

Cycle 22 GMT 22/ 5/2017 23:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 19 15.21 396 2 2
2 7 2002.44 39 14.66 3143 2 2
3 13 1870.16 29 14.61 2971 2 2
4 13 899.48 29 14.88 1647 2 2
5 13 115.40 29 15.19 453 2 2
6 8 -0.12 190 15.19 253 2 2

Cycle 21 GMT 12/ 5/2017 22:56: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 19 15.21 393 2 2
2 7 2001.64 39 14.66 3106 2 2
3 13 1616.40 29 14.69 2593 2 2
4 13 755.48 29 14.94 1451 2 2
5 13 131.80 29 15.18 482 2 2
6 13 15.20 29 15.22 278 2 2
7 8 -0.20 190 15.18 254 2 2

Cycle 20 GMT 2/ 5/2017 21:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 20 15.22 384 2 2
2 3 964.76 -1 15.58 0 2 2
3 7 2003.52 37 14.68 3137 2 2
4 13 1475.68 29 14.75 2395 2 2
5 13 753.84 29 14.94 1452 2 2
6 13 78.80 29 15.21 386 2 2
7 8 0.24 190 15.20 252 2 2

Cycle 19 GMT 22/ 4/2017 21: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 19 15.22 405 2 2
2 3 1026.24 1 15.29 1871 2 2
3 7 1995.80 37 14.68 3122 2 2
4 13 1724.56 29 14.68 2745 2 2
5 13 959.68 29 14.86 1733 2 2
6 13 92.28 29 15.22 405 2 2
7 13 47.12 29 15.22 327 2 2
8 8 -0.24 190 15.19 252 2 3

Cycle 18 GMT 12/ 4/2017 19:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 19 15.24 387 2 2
2 7 1995.76 37 14.70 3040 2 2
3 13 1736.40 29 14.68 2751 2 2
4 13 842.76 29 14.92 1578 2 2
5 13 106.00 29 15.21 431 2 2
6 13 13.60 29 15.24 270 2 2
7 8 -0.28 190 15.20 251 2 3

Cycle 17 GMT 2/ 4/2017 18:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 19 15.24 393 2 2
2 7 1993.64 38 14.70 3058 2 2
3 13 1487.20 26 14.76 2409 2 2
4 13 813.76 26 14.94 1539 2 2
5 13 114.24 26 15.22 446 2 2
6 13 25.64 26 15.24 288 2 2
7 8 -0.16 190 15.21 248 2 2

Cycle 16 GMT 23/ 3/2017 16:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 19 15.25 387 2 2
2 7 1994.44 37 14.72 3006 2 2
3 13 1472.88 26 14.78 2362 2 2
4 13 673.04 26 15.00 1335 2 2
5 13 131.64 26 15.21 472 2 2
6 13 30.92 26 15.25 296 2 2
7 8 0.04 190 15.22 246 2 2

Cycle 15 GMT 13/ 3/2017 14:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 19 15.24 383 2 2
2 7 1996.00 37 14.70 3103 2 2
3 13 1621.92 26 14.73 2619 2 2
4 13 752.68 26 14.97 1456 2 2
5 13 109.36 26 15.23 433 2 2
6 8 0.36 190 15.23 246 2 2

Cycle 14 GMT 3/ 3/2017 12:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 19 15.26 384 2 2
2 7 2000.04 38 14.72 3077 2 2
3 13 1486.44 26 14.77 2448 2 2
4 13 555.16 26 15.05 1151 2 2
5 13 132.28 26 15.22 475 2 2
6 13 14.76 26 15.26 273 2 2
7 8 -0.20 190 15.22 247 2 2

Cycle 13 GMT 21/ 2/2017 10:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 18 15.25 395 2 2
2 7 1994.72 37 14.72 3076 2 2
3 13 1496.44 26 14.77 2445 2 2
4 13 679.96 26 15.00 1339 2 2
5 13 76.12 26 15.25 374 2 2
6 8 0.08 190 15.25 242 2 2

Cycle 12 GMT 11/ 2/2017 9: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 19 15.24 389 2 2
2 7 1991.44 37 14.71 3113 2 2
3 13 1605.04 26 14.75 2571 2 2
4 13 745.92 26 14.98 1440 2 2
5 13 153.40 26 15.21 517 2 2
6 8 -0.04 190 15.23 250 2 2

Cycle 11 GMT 1/ 2/2017 7:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 19 15.25 395 2 2
2 7 1983.80 37 14.72 3121 2 2
3 13 1735.16 26 14.71 2777 2 2
4 13 852.20 26 14.94 1577 2 2
5 13 117.24 26 15.23 454 2 2
6 13 58.92 26 15.24 347 2 2
7 8 -0.32 190 15.22 250 2 2

Cycle 10 GMT 22/ 1/2017 6: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 19 15.26 387 2 2
2 7 1997.16 38 14.73 3131 2 2
3 13 1489.88 26 14.79 2440 2 2
4 13 787.32 26 14.96 1501 2 2
5 13 112.36 26 15.24 441 2 2
6 8 -0.04 190 15.24 248 2 2

Cycle 9 GMT 12/ 1/2017 4:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 19 15.26 382 2 2
2 7 1980.80 37 14.76 3054 2 2
3 13 1739.40 26 14.74 2727 2 2
4 13 886.52 26 14.93 1636 2 2
5 13 106.04 26 15.25 429 2 2
6 8 -0.04 190 15.25 248 2 2

Cycle 8 GMT 2/ 1/2017 2:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 18 15.25 391 2 2
2 7 1970.28 35 14.76 3107 2 2
3 13 1577.48 24 14.79 2552 2 2
4 13 767.60 24 14.99 1472 2 2
5 13 126.60 24 15.24 470 2 2
6 13 33.00 24 15.27 302 2 2
7 8 -0.16 190 15.24 249 2 2

Cycle 7 GMT 23/12/2016 0:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 19 15.25 388 2 2
2 7 1957.48 35 14.77 3071 2 2
3 13 1717.96 24 14.75 2763 2 2
4 13 892.48 24 14.94 1633 2 2
5 13 163.24 24 15.22 541 2 2
6 13 39.88 24 15.26 324 2 2
7 8 -0.12 190 15.23 252 2 3

Cycle 6 GMT 12/12/2016 23: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 17 15.25 392 2 2
2 3 1065.08 2 15.24 1907 2 2
3 3 1019.88 1 15.36 1852 2 2
4 7 1971.24 35 14.79 3014 2 2
5 13 1728.84 24 14.76 2722 2 2
6 13 798.48 24 14.99 1507 2 2
7 13 131.92 24 15.24 478 2 2
8 13 34.40 24 15.27 306 2 2
9 8 -0.20 190 15.24 250 2 2

Cycle 5 GMT 2/12/2016 21:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 24 15.26 409 2 2
2 3 748.44 -5 15.62 0 2 2
3 3 917.20 -2 15.64 0 2 2
4 7 1966.12 45 14.75 3001 2 2
5 13 1287.80 26 14.85 2136 2 2
6 13 575.48 26 15.05 1191 2 2
7 13 71.08 26 15.25 371 2 2
8 8 -0.04 190 15.24 252 2 2

Cycle 4 GMT 22/11/2016 19:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 17 15.25 407 2 2
2 10 1020.72 3 15.22 1824 2 2
3 3 942.64 -1 15.61 0 2 2
4 7 1505.56 46 14.93 2466 2 2
5 13 1006.36 26 14.97 1799 2 2
6 13 193.44 26 15.24 577 2 2
7 13 42.20 26 15.28 323 2 2
8 8 -0.08 190 15.25 252 2 2

Cycle 3 GMT 21/11/2016 19:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 16 15.25 397 2 2
2 3 1041.80 1 15.29 1865 2 2
3 7 1511.52 74 14.85 2466 2 2
4 13 175.64 25 15.25 545 2 2
5 13 43.40 25 15.29 319 2 2
6 8 -0.04 239 15.25 248 2 246

Cycle 2 GMT 20/11/2016 20:34: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 24 15.26 398 2 2
2 3 723.12 -5 15.63 0 2 2
3 3 891.44 -2 15.64 0 2 2
4 7 1508.96 74 14.86 2459 2 2
5 13 253.12 25 15.21 681 2 2
6 13 28.04 25 15.29 294 2 2
7 8 -0.04 240 15.25 248 2 46

Cycle 1 GMT 19/11/2016 21:14: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 24 15.43 361 2 2
2 3 720.44 -5 15.61 0 2 2
3 3 911.00 -2 15.62 0 2 2
4 7 1003.60 74 15.03 1764 2 2
5 13 49.80 25 15.32 329 2 2
6 8 -0.32 239 15.27 247 2 246

Cycle 0 GMT 19/11/2016 9:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 92.32 24 15.62 344 2 2
2 7 104.72 74 15.58 360 2 2
3 8 0.16 240 15.51 199 2 6