SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8734 WMO= 1902047


Cycle 219 GMT 15/12/2024 7:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 34 14.93 422 2 2
2 7 2012.96 36 14.78 2918 2 2
3 13 1514.32 19 14.79 2330 2 3
4 13 1016.96 19 14.81 1705 2 3
5 13 321.84 19 14.93 752 2 3
6 8 0.04 155 14.97 295 2 10

Cycle 218 GMT 5/12/2024 10: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 34 14.93 439 2 2
2 7 2013.84 37 14.79 2916 2 3
3 13 1522.88 19 14.79 2329 2 3
4 13 1022.44 19 14.80 1711 2 3
5 13 334.60 19 14.93 767 2 3
6 8 0.00 155 14.97 295 2 9
7 14 0.00 40 14.94 288 3 19

Cycle 217 GMT 25/11/2024 12:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 34 14.92 444 2 2
2 7 2014.28 37 14.79 2920 2 2
3 13 1520.40 19 14.79 2325 2 3
4 13 1022.72 19 14.81 1703 2 3
5 13 320.36 19 14.93 743 2 3
6 8 -0.04 155 14.97 291 2 10

Cycle 216 GMT 15/11/2024 14:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 34 14.93 451 2 2
2 7 2003.48 36 14.79 2902 2 3
3 13 1522.36 19 14.79 2344 2 3
4 13 1015.72 19 14.81 1695 2 3
5 13 319.64 19 14.94 738 2 3
6 8 0.16 155 14.97 291 2 9

Cycle 215 GMT 5/11/2024 17:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 34 14.93 444 2 2
2 7 2011.24 36 14.79 2918 2 3
3 13 1521.44 19 14.79 2338 2 3
4 13 1014.76 19 14.81 1688 2 3
5 13 342.04 19 14.93 773 2 3
6 8 0.28 155 14.97 295 2 10

Cycle 214 GMT 26/10/2024 19:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 34 14.92 440 2 2
2 7 2011.68 36 14.79 2900 2 3
3 13 1504.52 19 14.80 2310 2 4
4 13 1013.96 19 14.82 1689 2 4
5 13 318.28 19 14.94 740 2 3
6 8 0.04 155 14.97 294 2 10

Cycle 213 GMT 16/10/2024 22:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 34 14.93 436 2 2
2 7 2011.84 36 14.79 2912 2 3
3 13 1519.64 19 14.79 2336 2 3
4 13 1015.60 19 14.82 1696 2 3
5 13 330.52 19 14.94 756 2 3
6 8 0.12 155 14.97 294 2 9
7 14 0.12 40 14.95 292 2 15

Cycle 212 GMT 7/10/2024 0:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 34 14.94 423 2 2
2 7 2007.76 36 14.80 2911 2 3
3 13 1519.56 19 14.80 2335 2 3
4 13 1026.28 19 14.81 1713 2 3
5 13 513.32 19 14.89 1010 2 4
6 8 0.04 155 14.97 293 2 9

Cycle 211 GMT 27/ 9/2024 2:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 34 14.93 449 2 2
2 7 2003.20 36 14.80 2900 2 3
3 13 1502.20 19 14.80 2305 2 3
4 13 1002.64 19 14.83 1673 2 3
5 13 320.12 19 14.95 739 2 3
6 8 0.12 155 14.98 291 2 13

Cycle 210 GMT 17/ 9/2024 5:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 34 14.93 441 2 2
2 7 2009.24 36 14.79 2911 2 2
3 13 1676.16 19 14.78 2532 2 3
4 13 1005.08 19 14.82 1680 2 3
5 13 314.44 19 14.94 744 2 3
6 8 0.08 155 14.97 299 2 11

Cycle 209 GMT 7/ 9/2024 7:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 34 14.93 439 2 2
2 7 2014.84 36 14.79 2901 2 3
3 13 1525.92 19 14.79 2338 2 3
4 13 1054.88 19 14.81 1748 2 3
5 13 374.24 19 14.93 821 2 3
6 8 0.04 155 14.97 297 2 12

Cycle 208 GMT 28/ 8/2024 9:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 34 14.92 440 2 2
2 7 2006.04 36 14.80 2903 2 3
3 13 1672.96 19 14.78 2515 2 3
4 13 958.64 19 14.84 1618 2 3
5 13 274.64 19 14.95 680 2 3
6 8 0.04 155 14.98 291 2 10

Cycle 207 GMT 18/ 8/2024 12:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 34 14.94 435 2 2
2 7 2008.56 36 14.80 2900 2 3
3 13 1534.08 19 14.80 2351 2 3
4 13 1034.44 19 14.81 1718 2 3
5 13 320.12 19 14.93 742 2 3
6 8 0.12 155 14.96 294 2 8

Cycle 206 GMT 8/ 8/2024 14:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 34 14.93 439 2 2
2 7 2013.68 36 14.80 2901 2 3
3 13 1528.48 19 14.80 2333 2 3
4 13 1029.72 19 14.82 1699 2 3
5 13 207.72 19 14.97 575 2 3
6 8 0.08 155 14.98 283 2 11

Cycle 205 GMT 29/ 7/2024 17: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 34 14.94 444 2 2
2 7 2009.52 36 14.81 2893 2 3
3 13 1524.04 19 14.81 2321 2 3
4 13 1024.44 19 14.83 1688 2 3
5 13 322.96 19 14.94 731 2 3
6 8 0.12 155 14.98 283 2 9

Cycle 204 GMT 19/ 7/2024 19:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 34 14.94 431 2 2
2 7 2013.00 37 14.81 2892 2 3
3 13 1517.64 19 14.81 2315 2 3
4 13 1022.00 19 14.83 1684 2 3
5 13 329.08 19 14.94 743 2 3
6 8 0.24 155 14.98 284 2 10

Cycle 203 GMT 9/ 7/2024 21:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 34 14.94 432 2 2
2 7 2008.48 36 14.81 2887 2 3
3 13 1530.72 19 14.80 2329 2 3
4 13 1044.88 19 14.82 1724 2 3
5 13 216.56 19 14.97 592 2 3
6 8 -0.08 155 14.98 285 2 8
7 14 -0.08 40 14.96 283 2 14

Cycle 202 GMT 30/ 6/2024 0: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 34 14.94 434 2 2
2 7 2006.32 36 14.81 2880 2 3
3 13 1519.96 19 14.81 2321 2 3
4 13 1009.20 19 14.83 1676 2 3
5 13 322.88 19 14.95 744 2 3
6 8 0.16 155 14.98 283 2 7

Cycle 201 GMT 20/ 6/2024 2:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 34 14.94 451 2 2
2 7 2008.88 36 14.81 2898 2 2
3 13 1691.52 19 14.78 2546 2 3
4 13 997.84 19 14.83 1667 2 3
5 13 311.68 19 14.95 734 2 3
6 8 0.08 155 14.99 287 2 9
7 14 0.08 40 14.96 283 3 14

Cycle 200 GMT 10/ 6/2024 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 34 14.95 433 2 2
2 7 2006.92 36 14.81 2899 2 3
3 13 1512.76 19 14.81 2327 2 3
4 13 1009.24 19 14.83 1685 2 3
5 13 321.24 19 14.95 752 2 3
6 8 0.16 155 14.99 290 2 7
7 14 0.16 40 14.97 287 3 22

Cycle 199 GMT 31/ 5/2024 7: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 34 14.95 439 2 2
2 7 2005.88 36 14.80 2897 2 3
3 13 1507.16 19 14.81 2320 2 3
4 13 1007.72 19 14.83 1682 2 3
5 13 303.48 19 14.96 723 2 3
6 8 0.04 155 14.99 290 2 9

Cycle 198 GMT 21/ 5/2024 9:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 34 14.94 444 2 2
2 7 2007.64 36 14.80 2902 2 2
3 13 1510.68 19 14.81 2317 2 3
4 13 1017.60 19 14.83 1695 2 3
5 13 334.76 19 14.95 765 2 3
6 8 0.32 155 14.99 292 2 11

Cycle 197 GMT 11/ 5/2024 11:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 34 14.94 434 2 2
2 7 2003.60 36 14.81 2908 2 3
3 13 1525.48 19 14.80 2345 2 3
4 13 1026.08 19 14.82 1710 2 3
5 13 324.40 19 14.95 753 2 3
6 8 0.32 155 14.99 297 2 8

Cycle 196 GMT 1/ 5/2024 14:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 34 14.95 443 2 2
2 7 2013.88 36 14.80 2917 2 3
3 13 1683.36 19 14.78 2540 2 3
4 13 997.04 19 14.83 1669 2 3
5 13 306.72 19 14.96 728 2 3
6 8 -0.04 155 14.99 295 2 9
7 14 -0.04 40 14.97 291 3 16

Cycle 195 GMT 21/ 4/2024 16:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 34 14.96 437 2 2
2 7 2014.52 36 14.80 2923 2 3
3 13 1534.88 19 14.81 2356 2 3
4 13 1033.32 19 14.82 1721 2 3
5 13 334.28 19 14.95 767 2 3
6 8 0.24 155 14.99 296 2 7

Cycle 194 GMT 11/ 4/2024 19: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 34 14.95 433 2 2
2 7 2007.04 36 14.80 2906 2 2
3 13 1519.04 19 14.81 2336 2 3
4 13 1008.96 19 14.83 1686 2 3
5 13 184.08 19 14.99 565 2 3
6 8 -0.16 155 15.00 291 2 11

Cycle 193 GMT 1/ 4/2024 21:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 34 14.95 446 2 2
2 7 2004.48 36 14.81 2906 2 3
3 13 1388.40 19 14.82 2178 2 4
4 13 921.32 19 14.84 1566 2 3
5 13 250.04 19 14.97 651 2 3
6 8 0.00 155 14.99 296 2 9

Cycle 192 GMT 22/ 3/2024 23:33:13

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 34 14.95 439 2 2
2 7 2011.32 36 14.81 2910 2 3
3 13 1517.64 19 14.81 2328 2 3
4 13 1011.80 19 14.83 1687 2 3
5 13 317.36 19 14.95 743 2 3
6 8 0.12 155 14.99 295 2 7

Cycle 191 GMT 13/ 3/2024 1:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 34 14.95 436 2 2
2 7 2006.76 36 14.81 2903 2 3
3 13 1528.08 19 14.81 2335 2 3
4 13 1018.72 19 14.83 1698 2 3
5 13 339.56 19 14.95 768 2 3
6 8 0.12 155 14.99 292 2 7

Cycle 190 GMT 3/ 3/2024 4:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 34 14.95 435 2 2
2 7 2009.24 36 14.80 2907 2 3
3 13 1515.16 19 14.80 2333 2 3
4 13 1017.56 19 14.83 1693 2 3
5 13 334.92 19 14.95 765 2 3
6 8 0.24 155 14.99 289 2 7
7 14 0.24 40 14.97 286 2 13

Cycle 189 GMT 22/ 2/2024 6:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 34 14.95 439 2 2
2 7 2015.88 36 14.81 2906 2 3
3 13 1533.32 19 14.81 2337 2 3
4 13 1027.40 19 14.83 1704 2 3
5 13 332.20 19 14.95 758 2 3
6 8 0.12 155 14.99 294 2 8

Cycle 188 GMT 12/ 2/2024 9: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 34 14.96 435 2 2
2 7 2007.08 36 14.81 2909 2 3
3 13 1513.52 19 14.81 2325 2 3
4 13 1015.80 19 14.83 1690 2 3
5 13 346.68 19 14.95 778 2 3
6 8 0.28 155 14.99 289 2 9

Cycle 187 GMT 2/ 2/2024 11:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 34 14.96 441 2 2
2 7 2014.08 36 14.81 2912 2 3
3 13 1529.56 19 14.81 2343 2 3
4 13 1021.84 19 14.83 1699 2 3
5 13 333.56 19 14.96 764 2 3
6 8 0.24 155 15.00 294 2 8

Cycle 186 GMT 23/ 1/2024 13:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 34 14.96 445 2 2
2 7 2008.80 36 14.81 2897 2 3
3 13 1528.20 19 14.80 2347 2 3
4 13 1026.68 19 14.83 1722 2 3
5 13 333.60 19 14.96 769 2 3
6 8 -0.08 155 15.00 297 2 10

Cycle 185 GMT 13/ 1/2024 16: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 34 14.96 438 2 2
2 7 2005.00 36 14.80 2905 2 3
3 13 1508.80 19 14.81 2321 2 3
4 13 1001.48 19 14.83 1681 2 3
5 13 172.36 19 15.00 541 2 3
6 8 0.16 155 15.01 293 2 8

Cycle 184 GMT 3/ 1/2024 18:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 34 14.97 427 2 2
2 7 2005.44 36 14.80 2910 2 3
3 13 1669.80 19 14.80 2504 2 3
4 13 976.32 19 14.84 1647 2 4
5 13 301.44 19 14.97 722 2 3
6 8 0.12 155 15.00 298 2 9

Cycle 183 GMT 24/12/2023 20:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 34 14.95 445 2 2
2 7 2014.20 37 14.80 2914 2 3
3 13 1529.72 19 14.80 2352 2 3
4 13 886.44 19 14.85 1524 2 3
5 13 379.76 19 14.95 831 2 3
6 8 -0.04 155 15.00 295 2 9

Cycle 182 GMT 14/12/2023 23: 5: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 34 14.96 445 2 2
2 7 2008.68 37 14.80 2909 2 3
3 13 1537.40 19 14.80 2360 2 3
4 13 1041.28 19 14.83 1730 2 4
5 13 493.44 19 14.92 985 2 3
6 8 0.12 155 14.99 299 2 7

Cycle 181 GMT 5/12/2023 1:39:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 34 14.95 455 2 2
2 7 2007.64 37 14.81 2908 2 2
3 13 1519.64 19 14.82 2335 2 3
4 13 1015.04 19 14.84 1687 2 3
5 13 322.48 19 14.96 743 2 3
6 8 0.04 155 15.00 294 2 9

Cycle 180 GMT 25/11/2023 4: 3:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 34 14.96 454 2 2
2 7 2011.44 36 14.81 2907 2 3
3 13 1519.24 19 14.81 2328 2 3
4 13 1017.08 19 14.84 1691 2 3
5 13 328.04 19 14.96 756 2 3
6 8 -0.04 155 15.00 297 2 11

Cycle 179 GMT 15/11/2023 6:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 34 14.96 456 2 2
2 7 2015.00 36 14.81 2916 2 3
3 13 1520.76 19 14.81 2335 2 3
4 13 1016.16 19 14.84 1684 2 3
5 13 331.64 19 14.96 759 2 3
6 8 0.08 155 15.00 297 2 10

Cycle 178 GMT 5/11/2023 8:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 34 14.94 436 2 2
2 7 2006.96 36 14.81 2898 2 3
3 13 1513.88 19 14.81 2327 2 3
4 13 1023.40 19 14.83 1707 2 3
5 13 338.28 19 14.96 769 2 3
6 8 0.32 155 15.00 295 2 9

Cycle 177 GMT 26/10/2023 11: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 34 14.94 442 2 2
2 7 2007.16 36 14.80 2912 2 3
3 13 1519.88 19 14.80 2335 2 3
4 13 1007.28 19 14.83 1683 2 3
5 13 477.60 19 14.92 970 2 3
6 8 -0.20 155 14.99 300 2 12
7 14 -0.20 40 14.96 299 2 12

Cycle 176 GMT 16/10/2023 13:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 34 14.94 441 2 2
2 7 2007.36 36 14.81 2907 2 2
3 13 1521.52 19 14.81 2324 2 3
4 13 1016.32 19 14.84 1691 2 3
5 13 309.92 19 14.96 727 2 3
6 8 0.12 155 14.99 296 2 8

Cycle 175 GMT 6/10/2023 15:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 34 14.95 440 2 2
2 7 2010.36 36 14.82 2896 2 3
3 13 1526.12 19 14.81 2332 2 3
4 13 1017.76 19 14.84 1687 2 3
5 13 180.36 19 14.99 545 2 3
6 8 0.24 155 14.99 291 2 10
7 14 0.24 40 14.97 290 2 11

Cycle 174 GMT 26/ 9/2023 18:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 34 14.96 443 2 2
2 7 2005.12 36 14.82 2900 2 3
3 13 1529.52 19 14.81 2342 2 3
4 13 1031.40 19 14.84 1703 2 3
5 13 184.60 19 14.99 554 2 3
6 13 52.04 19 15.02 367 2 3
7 8 0.08 155 14.99 288 2 10

Cycle 173 GMT 16/ 9/2023 20:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 34 14.96 444 2 2
2 7 2010.32 36 14.82 2911 2 3
3 13 1526.24 19 14.81 2332 2 4
4 13 1011.16 19 14.84 1687 2 3
5 13 322.28 19 14.96 741 2 3
6 8 0.48 155 15.00 293 2 11
7 14 0.48 40 14.98 293 2 9

Cycle 172 GMT 6/ 9/2023 22:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 34 14.96 444 2 2
2 7 2007.24 37 14.82 2894 2 3
3 13 1519.00 19 14.82 2332 2 3
4 13 1023.88 19 14.84 1699 2 3
5 13 194.84 19 15.00 565 2 3
6 8 -0.28 155 15.00 291 2 8

Cycle 171 GMT 28/ 8/2023 0:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 34 14.95 431 2 2
2 7 2008.96 36 14.82 2900 2 2
3 13 1529.56 19 14.82 2336 2 3
4 13 1044.16 19 14.84 1718 2 3
5 13 338.56 19 14.97 764 2 3
6 8 0.16 155 15.01 293 2 7

Cycle 170 GMT 18/ 8/2023 3:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 34 14.96 430 2 2
2 7 2011.00 36 14.80 2904 2 3
3 13 1515.88 19 14.81 2324 2 3
4 13 1010.20 19 14.83 1687 2 3
5 13 309.92 19 14.97 733 2 3
6 8 0.12 155 15.00 293 2 8
7 14 0.12 40 14.98 293 2 10

Cycle 169 GMT 8/ 8/2023 5:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 34 14.96 443 2 2
2 7 2005.44 36 14.81 2898 2 3
3 13 1525.56 19 14.82 2343 2 3
4 13 1018.64 19 14.84 1693 2 3
5 13 308.56 19 14.97 721 2 3
6 8 0.00 155 15.00 290 2 6

Cycle 168 GMT 29/ 7/2023 8: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 34 14.96 447 2 2
2 7 2007.04 36 14.82 2896 2 2
3 13 1527.96 19 14.82 2340 2 3
4 13 1028.84 19 14.84 1703 2 3
5 13 331.92 19 14.97 760 2 3
6 8 0.16 155 15.00 293 2 7

Cycle 167 GMT 19/ 7/2023 10:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 34 14.97 432 2 2
2 7 2008.32 36 14.81 2908 2 3
3 13 1514.88 19 14.81 2323 2 4
4 13 1007.92 19 14.84 1683 2 3
5 13 179.36 19 15.00 547 2 3
6 8 0.32 155 15.00 293 2 6
7 14 0.32 40 14.98 293 3 16

Cycle 166 GMT 9/ 7/2023 12:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 34 14.96 442 2 2
2 7 2005.44 36 14.82 2901 2 3
3 13 1510.88 19 14.82 2325 2 3
4 13 994.64 19 14.85 1659 2 3
5 13 313.04 19 14.97 726 2 3
6 8 -0.16 155 15.01 288 2 8

Cycle 165 GMT 29/ 6/2023 15: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 34 14.98 436 2 2
2 7 2007.92 36 14.82 2892 2 3
3 13 1533.84 19 14.81 2348 2 3
4 13 1037.28 19 14.84 1711 2 3
5 13 362.00 19 14.96 797 2 3
6 8 0.12 155 15.00 287 2 9

Cycle 164 GMT 19/ 6/2023 17:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 34 14.98 441 2 2
2 7 2013.00 36 14.82 2907 2 3
3 13 1515.64 19 14.82 2328 2 3
4 13 1007.96 19 14.84 1675 2 3
5 13 323.56 19 14.97 742 2 3
6 8 0.28 155 15.01 285 2 9

Cycle 163 GMT 9/ 6/2023 19:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 34 14.98 452 2 2
2 7 2007.08 36 14.82 2910 2 3
3 13 1516.04 19 14.82 2336 2 3
4 13 997.68 19 14.85 1670 2 3
5 13 299.08 19 14.99 714 2 3
6 8 0.12 155 15.02 290 2 6

Cycle 162 GMT 30/ 5/2023 22:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 34 14.97 439 2 2
2 7 2003.48 36 14.81 2896 2 3
3 13 1499.04 19 14.82 2308 2 3
4 13 1158.08 19 14.82 1872 2 3
5 13 273.44 19 14.99 684 2 3
6 8 0.24 155 15.02 293 2 8

Cycle 161 GMT 21/ 5/2023 0:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 34 14.98 443 2 2
2 7 2007.64 36 14.81 2907 2 3
3 13 1388.28 19 14.82 2172 2 3
4 13 1052.32 19 14.83 1741 2 3
5 13 368.60 19 14.96 821 2 3
6 8 -0.04 155 15.01 297 2 9

Cycle 160 GMT 11/ 5/2023 2:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 34 14.97 441 2 2
2 7 1951.56 36 14.81 2845 2 3
3 13 1468.12 19 14.83 2275 2 3
4 13 956.48 19 14.86 1622 2 3
5 13 275.00 19 14.99 692 2 3
6 8 0.28 155 15.02 296 2 7

Cycle 159 GMT 1/ 5/2023 2:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 34 14.98 441 2 2
2 7 2002.92 36 14.81 2901 2 3
3 13 1652.64 19 14.80 2501 2 3
4 13 970.80 19 14.85 1634 2 3
5 13 439.72 19 14.94 917 2 3
6 8 -0.04 155 15.01 293 2 6

Cycle 158 GMT 21/ 4/2023 4:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 34 14.97 441 2 2
2 7 2004.32 37 14.81 2911 2 3
3 13 1486.84 19 14.82 2289 2 3
4 13 984.28 19 14.85 1651 2 4
5 13 288.80 19 14.98 702 2 3
6 8 0.24 155 15.02 288 2 8

Cycle 157 GMT 11/ 4/2023 7: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 34 14.97 432 2 2
2 7 2017.68 36 14.80 2931 2 3
3 13 1525.60 19 14.81 2338 2 3
4 13 991.32 19 14.85 1660 2 3
5 13 296.80 19 14.98 709 2 3
6 8 0.00 155 15.02 286 2 7

Cycle 156 GMT 1/ 4/2023 9: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 34 14.97 433 2 2
2 7 2002.92 36 14.80 2910 2 3
3 13 1509.52 19 14.81 2320 2 4
4 13 1018.40 19 14.83 1693 2 3
5 13 311.92 19 14.97 731 2 3
6 8 0.12 155 15.01 285 2 7
7 14 0.12 40 14.99 283 2 10

Cycle 155 GMT 22/ 3/2023 11:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 34 14.96 431 2 2
2 7 2008.04 36 14.81 2909 2 2
3 13 1530.64 19 14.81 2351 2 3
4 13 1024.96 19 14.83 1708 2 3
5 13 340.84 19 14.96 771 2 3
6 8 0.12 155 15.01 282 2 7

Cycle 154 GMT 12/ 3/2023 13:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 34 14.95 423 2 2
2 7 2002.88 36 14.82 2883 2 2
3 13 1666.72 19 14.80 2513 2 3
4 13 977.04 19 14.85 1638 2 3
5 13 301.76 19 14.97 705 2 3
6 8 0.20 155 15.00 278 2 6

Cycle 153 GMT 2/ 3/2023 15:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 34 14.96 422 2 2
2 7 2006.92 36 14.82 2889 2 2
3 13 1522.96 19 14.82 2326 2 3
4 13 1005.56 19 14.85 1661 2 3
5 13 325.48 19 14.96 737 2 3
6 13 16.56 19 15.02 309 2 3
7 8 -0.04 155 14.99 277 2 8
8 14 -0.04 40 14.97 276 2 12

Cycle 152 GMT 20/ 2/2023 18: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 34 14.95 426 2 2
2 7 2004.92 36 14.83 2890 2 2
3 13 1547.60 19 14.81 2350 2 3
4 13 1058.68 19 14.83 1729 2 3
5 13 354.64 19 14.96 778 2 3
6 13 33.84 19 15.02 331 2 3
7 8 0.00 155 14.99 277 2 9

Cycle 151 GMT 10/ 2/2023 20:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 34 14.97 420 2 2
2 7 2005.64 36 14.83 2892 2 2
3 13 1545.36 19 14.82 2352 2 3
4 13 917.36 19 14.87 1541 2 3
5 13 395.16 19 14.95 833 2 3
6 13 19.16 19 15.02 311 2 3
7 8 0.00 155 14.99 279 2 10
8 14 0.00 40 14.97 276 2 10

Cycle 150 GMT 31/ 1/2023 22:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 34 14.97 426 2 2
2 3 1016.00 1 15.16 1721 2 2
3 7 2007.48 37 14.83 2893 2 3
4 13 1542.88 19 14.81 2354 2 3
5 13 1043.36 19 14.83 1718 2 3
6 13 196.56 19 14.99 556 2 2
7 8 0.24 155 15.00 277 2 8

Cycle 149 GMT 22/ 1/2023 0:50: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 34 14.96 424 2 2
2 7 2014.60 36 14.82 2900 2 3
3 13 1678.72 19 14.80 2516 2 3
4 13 994.44 19 14.86 1644 2 3
5 13 299.20 19 14.97 699 2 3
6 8 0.00 155 15.01 278 2 9

Cycle 148 GMT 12/ 1/2023 3:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 34 14.97 433 2 2
2 7 2008.80 36 14.83 2900 2 3
3 13 1526.04 19 14.82 2327 2 3
4 13 1024.88 19 14.85 1679 2 3
5 13 312.20 19 14.97 718 2 3
6 8 0.08 155 15.01 279 2 7

Cycle 147 GMT 2/ 1/2023 5:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 34 14.97 434 2 2
2 7 2011.40 36 14.83 2896 2 3
3 13 1529.24 19 14.82 2339 2 3
4 13 1032.72 19 14.85 1694 2 3
5 13 326.80 19 14.97 741 2 3
6 8 0.04 155 15.01 282 2 7

Cycle 146 GMT 23/12/2022 7:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 34 14.96 430 2 2
2 7 2005.56 36 14.83 2890 2 3
3 13 1520.76 19 14.82 2321 2 3
4 13 1032.68 19 14.85 1699 2 3
5 13 319.36 19 14.97 734 2 3
6 8 0.00 155 15.01 281 2 8

Cycle 145 GMT 13/12/2022 10:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 34 14.97 435 2 2
2 7 2008.48 36 14.83 2896 2 3
3 13 1515.56 19 14.82 2318 2 3
4 13 1022.24 19 14.85 1685 2 3
5 13 318.80 19 14.97 730 2 3
6 8 0.36 155 15.01 282 2 6

Cycle 144 GMT 3/12/2022 12:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 34 14.96 436 2 2
2 7 2005.92 36 14.83 2892 2 3
3 13 1504.32 19 14.83 2310 2 3
4 13 1001.68 19 14.86 1653 2 3
5 13 300.76 19 14.98 699 2 3
6 8 0.08 155 15.01 277 2 7

Cycle 143 GMT 23/11/2022 15: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 34 14.96 418 2 2
2 7 2011.88 37 14.84 2895 2 3
3 13 1514.56 19 14.83 2311 2 3
4 13 1009.60 19 14.86 1666 2 3
5 13 320.16 19 14.98 726 2 3
6 8 0.12 155 15.01 280 2 7

Cycle 142 GMT 13/11/2022 17:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 34 14.97 423 2 2
2 7 2009.56 36 14.83 2900 2 3
3 13 1529.96 19 14.83 2330 2 3
4 13 1016.08 19 14.86 1675 2 3
5 13 321.84 19 14.98 726 2 3
6 8 0.20 155 15.01 278 2 10
7 14 0.20 40 14.99 277 2 8

Cycle 141 GMT 3/11/2022 19:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 34 14.97 433 2 2
2 7 2010.88 36 14.83 2896 2 3
3 13 1532.44 19 14.83 2333 2 3
4 13 1037.00 19 14.85 1702 2 3
5 13 338.60 19 14.97 756 2 3
6 8 0.24 155 15.01 283 2 8

Cycle 140 GMT 24/10/2022 22: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 34 14.99 432 2 2
2 7 2005.64 37 14.84 2885 2 3
3 13 1670.00 19 14.82 2501 2 3
4 13 1132.60 19 14.84 1822 2 3
5 13 408.40 19 14.96 848 2 3
6 8 0.00 155 15.01 280 2 5

Cycle 139 GMT 15/10/2022 0:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 34 14.99 432 2 2
2 7 2006.24 36 14.85 2890 2 2
3 13 1524.00 19 14.84 2319 2 3
4 13 1038.64 19 14.86 1703 2 3
5 13 366.28 19 14.98 787 2 3
6 8 0.04 155 15.03 275 2 6

Cycle 138 GMT 5/10/2022 3:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 34 14.99 430 2 2
2 7 2005.04 36 14.84 2897 2 2
3 13 1515.60 19 14.84 2322 2 3
4 13 1004.48 19 14.87 1670 2 4
5 13 319.28 19 15.00 733 2 3
6 8 0.04 155 15.03 282 2 10

Cycle 137 GMT 25/ 9/2022 5:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 34 14.98 431 2 2
2 7 2011.76 36 14.82 2902 2 3
3 13 1518.60 19 14.83 2328 2 3
4 13 1018.44 19 14.85 1692 2 3
5 13 332.40 19 14.98 750 2 3
6 8 0.00 155 15.02 283 2 6

Cycle 136 GMT 15/ 9/2022 7:52:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 34 14.99 419 2 2
2 7 2005.52 36 14.84 2882 2 3
3 13 1523.52 19 14.83 2322 2 3
4 13 1015.88 19 14.85 1677 2 3
5 13 311.08 19 14.99 717 2 3
6 8 0.32 155 15.02 279 2 7

Cycle 135 GMT 5/ 9/2022 10:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 34 14.98 426 2 2
2 7 2009.16 37 14.83 2890 2 3
3 13 1534.24 19 14.83 2344 2 3
4 13 1033.04 19 14.86 1695 2 4
5 13 328.00 19 14.98 739 2 3
6 13 27.88 19 15.04 324 2 3
7 8 -0.04 155 15.01 279 2 9

Cycle 134 GMT 26/ 8/2022 12:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 34 14.98 430 2 2
2 7 2006.12 36 14.83 2891 2 3
3 13 1531.24 19 14.83 2337 2 3
4 13 1033.28 19 14.86 1700 2 3
5 13 338.72 19 14.98 752 2 3
6 8 0.12 155 15.02 282 2 5

Cycle 133 GMT 16/ 8/2022 14:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 34 14.98 443 2 2
2 7 2008.64 37 14.84 2888 2 3
3 13 1523.88 19 14.84 2328 2 3
4 13 1014.00 19 14.86 1674 2 4
5 13 321.16 19 14.99 726 2 3
6 8 0.00 155 15.02 276 2 8

Cycle 132 GMT 6/ 8/2022 17:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 34 14.98 422 2 2
2 7 2009.44 36 14.84 2896 2 3
3 13 1522.64 19 14.84 2323 2 3
4 13 1019.12 19 14.86 1683 2 3
5 13 324.52 19 14.99 730 2 3
6 8 0.00 155 15.02 280 2 6
7 14 0.00 40 15.00 280 2 13

Cycle 131 GMT 27/ 7/2022 19:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 34 14.98 424 2 2
2 7 2003.56 36 14.85 2886 2 2
3 13 1520.08 19 14.83 2324 2 3
4 13 1015.60 19 14.87 1673 2 3
5 13 323.48 19 14.99 728 2 3
6 8 0.24 155 15.03 279 2 5
7 14 0.24 40 15.01 278 2 9

Cycle 130 GMT 17/ 7/2022 21:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 34 14.99 420 2 2
2 7 2006.88 36 14.85 2890 2 2
3 13 1543.12 19 14.84 2345 2 3
4 13 1051.88 19 14.86 1724 2 3
5 13 518.28 19 14.95 1001 2 3
6 8 0.08 155 15.02 279 2 7
7 14 0.08 40 15.00 276 2 15

Cycle 129 GMT 8/ 7/2022 0:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 34 15.00 444 2 2
2 7 2011.52 36 14.85 2903 2 2
3 13 1530.56 19 14.83 2342 2 3
4 13 1041.12 19 14.86 1707 2 3
5 13 357.56 19 14.98 784 2 3
6 8 -0.08 155 15.03 278 2 7

Cycle 128 GMT 28/ 6/2022 2:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 34 15.00 433 2 2
2 7 2007.84 36 14.84 2887 2 3
3 13 1663.96 19 14.83 2502 2 3
4 13 970.76 19 14.88 1631 2 4
5 13 444.36 19 14.97 904 2 3
6 8 0.16 155 15.03 284 2 8

Cycle 127 GMT 18/ 6/2022 4:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 34 15.00 426 2 2
2 7 2012.28 36 14.84 2897 2 3
3 13 1525.72 19 14.84 2326 2 3
4 13 1013.64 19 14.87 1678 2 3
5 13 322.12 19 15.00 733 2 3
6 8 0.00 155 15.04 280 2 7

Cycle 126 GMT 8/ 6/2022 7:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 34 15.00 431 2 2
2 7 2005.36 36 14.84 2895 2 2
3 13 1517.64 19 14.84 2324 2 3
4 13 1012.56 19 14.87 1684 2 3
5 13 323.36 19 15.00 737 2 3
6 8 0.44 155 15.04 278 2 6

Cycle 125 GMT 29/ 5/2022 9:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 34 15.01 426 2 2
2 7 2011.16 37 14.84 2897 2 3
3 13 1517.88 19 14.84 2321 2 3
4 13 1002.68 19 14.87 1667 2 3
5 13 312.92 19 15.00 725 2 3
6 8 0.12 155 15.04 281 2 5

Cycle 124 GMT 19/ 5/2022 11:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 34 14.99 440 2 2
2 7 2005.32 36 14.84 2882 2 2
3 13 1499.24 19 14.84 2296 2 3
4 13 988.16 19 14.88 1646 2 3
5 13 307.28 19 15.01 716 2 3
6 8 0.24 155 15.04 280 2 5

Cycle 123 GMT 9/ 5/2022 14:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 34 15.00 406 2 2
2 7 2005.96 36 14.84 2892 2 3
3 13 1505.52 19 14.84 2311 2 3
4 13 1005.20 19 14.87 1670 2 3
5 13 321.88 19 15.00 735 2 3
6 8 0.16 155 15.03 280 2 5

Cycle 122 GMT 29/ 4/2022 16:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 34 15.00 425 2 2
2 7 2003.04 36 14.85 2883 2 2
3 13 1515.72 19 14.84 2319 2 3
4 13 1006.36 19 14.88 1668 2 3
5 13 310.92 19 15.00 717 2 3
6 8 -0.08 155 15.04 279 2 5

Cycle 121 GMT 19/ 4/2022 18:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 34 14.99 403 2 2
2 7 2011.80 37 14.85 2898 2 3
3 13 1523.84 19 14.84 2337 2 3
4 13 1025.88 19 14.87 1693 2 3
5 13 333.04 19 15.00 749 2 3
6 8 0.04 155 15.04 280 2 7

Cycle 120 GMT 9/ 4/2022 21:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 34 15.00 428 2 2
2 7 2003.80 36 14.85 2899 2 3
3 13 1531.92 19 14.84 2352 2 3
4 13 1025.28 19 14.87 1696 2 3
5 13 338.96 19 15.00 760 2 3
6 13 35.60 19 15.06 333 2 3
7 8 0.20 155 15.03 279 2 9

Cycle 119 GMT 30/ 3/2022 23:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 34 15.00 424 2 2
2 7 2003.44 37 14.85 2890 2 3
3 13 1504.24 19 14.85 2311 2 3
4 13 996.00 19 14.88 1662 2 3
5 13 322.04 19 15.01 733 2 3
6 13 29.72 19 15.06 328 2 2
7 8 0.24 155 15.04 280 2 8

Cycle 118 GMT 21/ 3/2022 1:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 34 15.01 423 2 2
2 7 2005.48 36 14.85 2890 2 3
3 13 1512.96 19 14.85 2323 2 3
4 13 1001.12 19 14.88 1668 2 3
5 13 301.00 19 15.01 706 2 2
6 13 28.28 19 15.06 329 2 3
7 8 0.12 155 15.04 281 2 8

Cycle 117 GMT 11/ 3/2022 4: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 34 15.00 427 2 2
2 7 2003.68 36 14.85 2898 2 3
3 13 1510.24 19 14.85 2314 2 3
4 13 1005.88 19 14.88 1672 2 3
5 13 313.44 19 15.01 726 2 3
6 13 28.92 19 15.06 327 2 2
7 8 0.12 155 15.04 281 2 8

Cycle 116 GMT 1/ 3/2022 6:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 34 15.01 438 2 2
2 7 2009.24 36 14.85 2904 2 3
3 13 1508.96 19 14.85 2316 2 3
4 13 1007.92 19 14.88 1675 2 3
5 13 326.28 19 15.01 746 2 3
6 13 28.24 19 15.07 331 2 3
7 8 0.04 155 15.04 281 2 7

Cycle 115 GMT 19/ 2/2022 8:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 34 15.00 429 2 2
2 7 2011.48 36 14.84 2907 2 2
3 13 1509.16 19 14.84 2319 2 3
4 13 1014.20 19 14.88 1682 2 4
5 13 314.96 19 15.01 730 2 3
6 8 0.32 155 15.05 285 2 7

Cycle 114 GMT 9/ 2/2022 11: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 34 15.00 437 2 2
2 7 2004.96 36 14.85 2894 2 3
3 13 1510.80 19 14.85 2311 2 3
4 13 1007.68 19 14.88 1678 2 3
5 13 309.72 19 15.01 724 2 3
6 13 22.36 19 15.07 326 2 2
7 8 -0.04 155 15.04 286 2 8

Cycle 113 GMT 30/ 1/2022 13:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 34 15.00 428 2 2
2 7 2007.08 37 14.85 2895 2 3
3 13 1505.36 19 14.85 2309 2 3
4 13 996.64 19 14.88 1653 2 3
5 13 306.28 19 15.01 713 2 3
6 8 -0.08 155 15.04 283 2 5

Cycle 112 GMT 20/ 1/2022 15:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 34 15.01 425 2 2
2 7 2005.96 36 14.86 2894 2 3
3 13 1511.20 19 14.86 2310 2 3
4 13 1003.24 19 14.89 1666 2 3
5 13 311.20 19 15.01 717 2 3
6 8 0.00 155 15.04 278 2 8

Cycle 111 GMT 10/ 1/2022 18:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 34 15.02 436 2 2
2 7 2004.52 37 14.86 2894 2 3
3 13 1519.36 19 14.85 2322 2 3
4 13 1022.68 19 14.88 1689 2 3
5 13 328.36 19 15.01 741 2 3
6 8 0.08 155 15.05 280 2 6

Cycle 110 GMT 31/12/2021 20:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 34 15.00 435 2 2
2 7 2005.40 36 14.86 2901 2 3
3 13 1659.12 19 14.84 2503 2 3
4 13 968.00 19 14.90 1622 2 3
5 13 285.60 19 15.03 684 2 3
6 8 0.12 155 15.06 282 2 4

Cycle 109 GMT 21/12/2021 23: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 34 14.99 423 2 2
2 7 2004.12 36 14.85 2883 2 2
3 13 1514.76 19 14.85 2315 2 3
4 13 1008.52 19 14.88 1681 2 3
5 13 302.88 19 15.01 720 2 3
6 8 0.24 155 15.04 286 2 6

Cycle 108 GMT 12/12/2021 1:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 34 15.00 421 2 2
2 7 2005.56 36 14.86 2881 2 2
3 13 1522.80 19 14.86 2323 2 3
4 13 1017.68 19 14.88 1679 2 3
5 13 318.16 19 15.01 724 2 2
6 13 24.84 19 15.06 316 2 2
7 8 0.12 155 15.03 278 2 6

Cycle 107 GMT 2/12/2021 3:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 34 15.00 419 2 2
2 7 2009.00 36 14.86 2885 2 2
3 13 1519.52 19 14.85 2324 2 3
4 13 1022.44 19 14.89 1677 2 3
5 13 324.88 19 15.01 730 2 2
6 8 0.20 155 15.04 277 2 7

Cycle 106 GMT 22/11/2021 5:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 34 15.01 432 2 2
2 7 2003.92 36 14.87 2889 2 2
3 13 1525.60 19 14.86 2326 2 3
4 13 1024.76 19 14.89 1686 2 3
5 13 341.48 19 15.01 751 2 2
6 8 0.20 155 15.05 278 2 6

Cycle 105 GMT 12/11/2021 8:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 34 15.01 428 2 2
2 7 2012.72 36 14.86 2905 2 3
3 13 1507.92 19 14.86 2314 2 3
4 13 1017.72 19 14.89 1680 2 3
5 13 332.60 19 15.01 746 2 3
6 8 0.16 155 15.05 280 2 8

Cycle 104 GMT 2/11/2021 10:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 33 15.02 438 2 2
2 7 2004.16 36 14.86 2886 2 3
3 13 1513.60 19 14.86 2317 2 3
4 13 1007.08 19 14.89 1667 2 3
5 13 314.32 19 15.02 719 2 2
6 8 0.00 155 15.05 281 2 6

Cycle 103 GMT 23/10/2021 13: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 34 15.01 431 2 2
2 7 2009.00 36 14.87 2903 2 3
3 13 1506.72 19 14.87 2316 2 3
4 13 1001.48 19 14.90 1665 2 3
5 13 297.52 19 15.03 700 2 3
6 8 -0.04 155 15.06 284 2 5

Cycle 102 GMT 13/10/2021 15:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 33 14.99 438 2 2
2 3 1016.28 1 15.20 1731 2 2
3 7 2008.52 36 14.86 2886 2 2
4 13 1661.60 19 14.85 2502 2 3
5 13 1113.36 19 14.88 1816 2 3
6 13 407.32 19 15.01 860 2 3
7 8 0.08 155 15.05 289 2 7

Cycle 101 GMT 3/10/2021 17:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 33 15.02 425 2 2
2 3 1021.08 1 15.17 1743 2 2
3 7 2002.36 37 14.87 2891 2 3
4 13 1500.84 19 14.87 2299 2 3
5 13 988.04 19 14.90 1645 2 3
6 13 454.28 19 14.99 918 2 3
7 13 44.80 19 15.06 354 2 2
8 8 -0.12 155 15.04 286 2 7
9 14 -0.12 40 15.01 285 2 9

Cycle 100 GMT 23/ 9/2021 20:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 33 15.04 438 2 2
2 7 2005.44 36 14.88 2898 2 3
3 13 1507.04 19 14.87 2312 2 3
4 13 1005.68 19 14.91 1666 2 3
5 13 319.16 19 15.03 728 2 2
6 8 0.08 155 15.06 280 2 6

Cycle 99 GMT 13/ 9/2021 22:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 32 15.05 436 2 2
2 3 1041.40 1 15.14 1774 2 3
3 7 2005.04 36 14.88 2900 2 3
4 13 1502.92 19 14.89 2302 2 3
5 13 987.04 19 14.92 1653 2 3
6 13 287.40 19 15.05 687 2 3
7 8 0.12 155 15.08 283 2 5

Cycle 98 GMT 4/ 9/2021 1:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 32 15.04 447 2 2
2 3 1016.20 1 15.13 1771 2 2
3 7 2005.08 36 14.88 2908 2 3
4 13 1509.80 19 14.89 2323 2 3
5 13 1156.72 19 14.90 1876 2 3
6 13 415.00 19 15.04 877 2 3
7 8 0.16 155 15.09 291 2 10
8 14 0.16 40 15.07 288 2 9

Cycle 97 GMT 25/ 8/2021 3:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 32 15.04 461 2 2
2 7 2003.24 37 14.87 2910 2 3
3 13 1489.40 19 14.89 2310 2 3
4 13 834.40 19 14.95 1468 2 3
5 13 168.96 19 15.09 562 2 3
6 8 -0.08 155 15.09 310 2 5

Cycle 96 GMT 15/ 8/2021 5:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 32 15.03 456 2 2
2 7 2010.40 36 14.87 2907 2 3
3 13 1483.56 19 14.89 2296 2 3
4 13 975.12 19 14.93 1653 2 3
5 13 283.72 19 15.06 720 2 3
6 8 0.16 155 15.08 316 2 8

Cycle 95 GMT 5/ 8/2021 7:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 33 15.03 456 2 2
2 7 2007.00 36 14.87 2904 2 3
3 13 1368.84 19 14.90 2157 2 3
4 13 882.56 19 14.94 1535 2 3
5 13 351.20 19 15.04 818 2 3
6 8 0.20 155 15.08 313 2 9

Cycle 94 GMT 26/ 7/2021 9:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 33 15.03 439 2 2
2 7 2004.80 36 14.86 2910 2 3
3 13 1487.88 19 14.88 2296 2 3
4 13 960.40 19 14.92 1637 2 4
5 13 432.68 19 15.01 928 2 4
6 8 0.04 155 15.08 311 2 8

Cycle 93 GMT 16/ 7/2021 11:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 33 15.01 434 2 2
2 7 2004.20 36 14.87 2904 2 3
3 13 1486.44 19 14.89 2297 2 3
4 13 967.84 19 14.92 1634 2 3
5 13 284.60 19 15.05 706 2 3
6 8 0.08 155 15.07 298 2 8

Cycle 92 GMT 6/ 7/2021 14: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 33 15.02 439 2 2
2 7 2010.32 36 14.87 2914 2 3
3 13 1520.36 19 14.88 2339 2 3
4 13 1010.44 19 14.90 1683 2 3
5 13 338.56 19 15.03 780 2 3
6 8 0.08 155 15.06 301 2 8
7 14 0.08 40 15.04 298 2 11

Cycle 91 GMT 26/ 6/2021 16:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 34 15.02 423 2 2
2 7 2005.28 36 14.88 2896 2 2
3 13 1499.88 19 14.89 2297 2 3
4 13 987.72 19 14.92 1642 2 3
5 13 295.60 19 15.05 694 2 2
6 8 0.32 155 15.07 283 2 7
7 14 0.32 40 15.05 283 2 8

Cycle 90 GMT 16/ 6/2021 18:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 34 15.04 428 2 2
2 7 2003.52 37 14.88 2894 2 2
3 13 1489.72 19 14.89 2301 2 3
4 13 980.96 19 14.92 1637 2 3
5 13 281.36 19 15.05 682 2 2
6 13 23.16 19 15.10 319 2 2
7 8 0.08 155 15.07 282 2 6
8 14 0.08 40 15.04 282 2 9

Cycle 89 GMT 6/ 6/2021 20:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.68 33 15.05 432 2 2
2 7 2010.56 36 14.89 2897 2 2
3 13 1514.52 19 14.89 2320 2 3
4 13 1013.48 19 14.92 1674 2 3
5 13 297.88 19 15.05 699 2 2
6 13 25.56 19 15.10 320 2 2
7 8 -0.04 155 15.08 280 2 8

Cycle 88 GMT 27/ 5/2021 22:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 32 15.07 419 2 2
2 3 1063.68 2 15.17 1810 2 3
3 7 2011.72 36 14.89 2895 2 2
4 13 1509.84 19 14.90 2313 2 3
5 13 1021.88 19 14.92 1687 2 3
6 13 317.04 19 15.05 723 2 3
7 8 0.00 155 15.09 276 2 5
8 14 0.00 40 15.06 274 2 7

Cycle 87 GMT 18/ 5/2021 0:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 30 15.08 431 2 2
2 10 1026.68 2 15.09 1760 2 2
3 7 2005.84 36 14.90 2904 2 2
4 13 1514.00 19 14.91 2321 2 3
5 13 994.72 19 14.95 1655 2 4
6 13 291.72 19 15.09 691 2 3
7 8 0.00 155 15.12 281 2 5
8 14 0.00 40 15.09 280 2 10

Cycle 86 GMT 8/ 5/2021 3:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 31 15.05 446 2 2
2 3 963.04 -1 15.39 0 2 2
3 3 1017.32 1 15.15 1801 2 3
4 7 2019.28 36 14.88 2935 2 3
5 13 1517.36 19 14.90 2336 2 3
6 13 943.72 19 14.95 1617 2 3
7 13 246.52 19 15.10 655 2 3
8 13 50.52 19 15.13 372 2 3
9 8 0.24 155 15.11 291 2 9

Cycle 85 GMT 28/ 4/2021 5:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 30 15.07 438 2 2
2 3 1039.28 1 15.11 1832 2 3
3 7 2004.08 36 14.88 2914 2 3
4 13 1481.68 19 14.90 2297 2 3
5 13 801.24 19 14.97 1441 2 3
6 13 158.56 19 15.10 556 2 3
7 8 0.16 155 15.10 316 2 11
8 14 0.16 40 15.08 311 2 12

Cycle 84 GMT 18/ 4/2021 7:20: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 32 15.05 461 2 2
2 3 959.32 -1 15.39 0 2 2
3 7 2003.12 36 14.89 2910 2 2
4 13 1490.68 19 14.91 2303 2 3
5 13 965.56 19 14.94 1649 2 3
6 13 278.12 19 15.08 709 2 3
7 13 22.96 19 15.13 340 2 3
8 8 0.00 155 15.11 297 2 9

Cycle 83 GMT 8/ 4/2021 9:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 32 15.07 440 2 2
2 7 2003.72 36 14.89 2920 2 3
3 13 1338.16 19 14.92 2117 2 3
4 13 849.96 19 14.96 1500 2 3
5 13 330.64 19 15.05 801 2 3
6 13 35.36 19 15.12 377 2 3
7 8 0.04 155 15.09 316 2 9

Cycle 82 GMT 29/ 3/2021 11:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 33 15.07 438 2 2
2 3 963.16 -1 15.40 0 2 2
3 7 2009.32 36 14.88 2916 2 3
4 13 1342.52 19 14.91 2116 2 3
5 13 1012.04 19 14.93 1698 2 3
6 13 285.68 19 15.07 721 2 3
7 8 0.08 155 15.10 305 2 6

Cycle 81 GMT 19/ 3/2021 13:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 33 15.06 410 2 2
2 7 2003.16 36 14.88 2909 2 2
3 13 1483.40 19 14.90 2291 2 3
4 13 964.60 19 14.93 1637 2 3
5 13 266.32 19 15.07 691 2 3
6 8 0.28 155 15.10 303 2 6

Cycle 80 GMT 9/ 3/2021 15:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 33 15.07 401 2 2
2 7 2002.24 36 14.89 2892 2 2
3 13 1496.60 19 14.89 2305 2 3
4 13 963.28 19 14.94 1622 2 3
5 13 286.40 19 15.07 693 2 3
6 13 60.44 19 15.11 374 2 2
7 8 -0.20 155 15.10 279 2 7
8 14 -0.20 40 15.07 278 3 10

Cycle 79 GMT 27/ 2/2021 17:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 32 15.08 428 2 2
2 3 1026.28 1 15.20 1730 2 2
3 7 2007.76 37 14.90 2890 2 3
4 13 1500.32 19 14.91 2311 2 3
5 13 983.80 19 14.96 1636 2 3
6 13 297.44 19 15.08 697 2 2
7 13 62.96 19 15.13 365 2 2
8 8 0.12 155 15.11 272 2 9

Cycle 78 GMT 17/ 2/2021 20: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 32 15.09 424 2 2
2 7 2007.24 36 14.90 2910 2 3
3 13 1492.92 19 14.91 2295 2 3
4 13 976.12 19 14.96 1639 2 3
5 13 271.12 19 15.10 670 2 2
6 13 26.04 19 15.15 326 2 2
7 8 0.04 155 15.12 284 2 7
8 14 0.04 40 15.10 281 2 9

Cycle 77 GMT 7/ 2/2021 22: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 33 15.08 414 2 2
2 7 1724.12 36 14.96 2578 2 3
3 13 1407.36 19 14.96 2207 2 3
4 13 885.44 19 15.00 1537 2 3
5 13 193.64 19 15.13 582 2 3
6 13 42.56 19 15.16 363 2 2
7 8 0.08 155 15.13 292 2 5
8 14 0.08 40 15.11 288 2 8

Cycle 76 GMT 28/ 1/2021 21:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 33 15.09 403 2 2
2 7 2008.08 36 14.89 2911 2 3
3 13 1493.84 19 14.91 2302 2 3
4 13 962.92 19 14.95 1629 2 3
5 13 265.32 19 15.10 672 2 3
6 13 64.00 19 15.14 386 2 3
7 8 0.08 155 15.12 286 2 7

Cycle 75 GMT 19/ 1/2021 0: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 33 15.09 432 2 2
2 7 2009.72 36 14.90 2909 2 2
3 13 1493.96 19 14.92 2295 2 3
4 13 981.72 19 14.96 1653 2 3
5 13 277.24 19 15.10 680 2 3
6 13 58.48 19 15.14 368 2 2
7 8 0.12 155 15.12 279 2 6

Cycle 74 GMT 9/ 1/2021 2:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 33 15.08 438 2 2
2 7 2003.68 36 14.91 2899 2 2
3 13 1502.04 19 14.91 2326 2 3
4 13 974.04 19 14.96 1641 2 3
5 13 273.52 19 15.10 674 2 3
6 8 0.08 155 15.13 285 2 5

Cycle 73 GMT 30/12/2020 4:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 33 15.10 429 2 2
2 7 2007.64 36 14.91 2901 2 2
3 13 1489.44 19 14.92 2290 2 3
4 13 975.16 19 14.96 1633 2 3
5 13 272.12 19 15.11 670 2 2
6 13 19.60 19 15.15 327 2 2
7 8 0.16 155 15.12 292 2 8

Cycle 72 GMT 20/12/2020 6:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 33 15.09 436 2 2
2 7 2011.64 36 14.92 2908 2 3
3 13 1505.76 19 14.92 2323 2 3
4 13 989.84 19 14.97 1652 2 3
5 13 280.96 19 15.11 675 2 3
6 8 0.00 155 15.14 279 2 5

Cycle 71 GMT 10/12/2020 8:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 33 15.10 436 2 2
2 7 2006.00 36 14.91 2908 2 3
3 13 1501.64 19 14.93 2319 2 3
4 13 996.72 19 14.97 1665 2 3
5 13 297.52 19 15.11 706 2 3
6 13 10.72 19 15.16 311 2 2
7 8 0.08 155 15.13 285 2 10

Cycle 70 GMT 30/11/2020 11:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 33 15.10 415 2 2
2 7 2003.44 36 14.92 2915 2 2
3 13 1495.12 19 14.94 2294 2 3
4 13 846.84 19 15.00 1462 2 3
5 13 341.04 19 15.11 767 2 3
6 8 -0.04 155 15.15 286 2 5

Cycle 69 GMT 20/11/2020 13:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 33 15.11 431 2 2
2 7 2003.04 37 14.91 2902 2 2
3 13 1363.00 19 14.95 2139 2 3
4 13 861.60 19 15.00 1491 2 3
5 13 177.32 19 15.14 545 2 2
6 8 -0.04 155 15.14 288 2 5

Cycle 68 GMT 10/11/2020 15:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 33 15.12 425 2 2
2 7 2002.72 36 14.92 2899 2 3
3 13 1495.80 19 14.93 2309 2 3
4 13 976.60 19 14.98 1640 2 3
5 13 270.72 19 15.13 674 2 3
6 13 24.08 19 15.17 327 2 2
7 8 0.08 155 15.15 287 2 6

Cycle 67 GMT 31/10/2020 18: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 33 15.11 435 2 2
2 7 2007.84 36 14.92 2908 2 3
3 13 1494.12 19 14.93 2299 2 3
4 13 850.44 19 15.01 1476 2 3
5 13 327.60 19 15.12 754 2 3
6 8 0.08 155 15.15 287 2 8

Cycle 66 GMT 21/10/2020 20: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 33 15.12 440 2 2
2 7 2010.96 36 14.91 2909 2 3
3 13 1495.72 19 14.93 2304 2 3
4 13 983.00 19 14.98 1652 2 3
5 13 286.20 19 15.13 695 2 3
6 8 0.28 155 15.16 289 2 7

Cycle 65 GMT 11/10/2020 22: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 33 15.10 439 2 2
2 7 2004.72 36 14.93 2902 2 2
3 13 1486.96 19 14.94 2292 2 3
4 13 969.64 19 14.99 1637 2 3
5 13 258.04 19 15.14 657 2 3
6 8 -0.04 155 15.16 286 2 6

Cycle 64 GMT 2/10/2020 0:30:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 33 15.12 420 2 2
2 7 2005.56 36 14.93 2899 2 3
3 13 1489.56 19 14.94 2299 2 3
4 13 981.64 19 14.99 1649 2 3
5 13 272.76 19 15.13 672 2 2
6 13 20.40 19 15.18 325 2 2
7 8 -0.04 155 15.15 288 2 7
8 14 -0.04 40 15.13 286 2 9

Cycle 63 GMT 22/ 9/2020 2:41: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 33 15.12 436 2 2
2 7 2007.68 37 14.93 2912 2 3
3 13 1481.12 19 14.95 2284 2 3
4 13 967.80 19 15.00 1628 2 3
5 13 277.68 19 15.14 683 2 2
6 8 0.00 155 15.16 284 2 11
7 14 0.00 40 15.14 282 2 7

Cycle 62 GMT 12/ 9/2020 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 33 15.13 431 2 2
2 7 2007.48 36 14.93 2909 2 2
3 13 1505.28 19 14.95 2311 2 3
4 13 985.40 19 15.00 1646 2 3
5 13 283.20 19 15.14 682 2 2
6 8 0.24 155 15.16 286 2 6

Cycle 61 GMT 2/ 9/2020 7:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 15.14 436 2 2
2 7 2002.88 36 14.94 2893 2 3
3 13 1504.68 19 14.95 2308 2 3
4 13 853.76 19 15.04 1459 2 3
5 13 194.32 19 15.17 553 2 2
6 8 0.32 155 15.17 280 2 5

Cycle 60 GMT 23/ 8/2020 9:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 33 15.15 433 2 2
2 7 2004.60 36 14.95 2891 2 2
3 13 1495.32 19 14.96 2299 2 3
4 13 858.08 19 15.04 1466 2 3
5 13 328.28 19 15.14 745 2 3
6 8 0.24 155 15.18 282 2 11
7 14 0.24 40 15.16 279 2 8

Cycle 59 GMT 13/ 8/2020 11:33:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 33 15.14 435 2 2
2 7 2003.36 36 14.94 2897 2 3
3 13 1505.24 19 14.96 2312 2 3
4 13 993.80 19 15.01 1659 2 3
5 13 278.72 19 15.15 681 2 3
6 8 0.00 155 15.18 283 2 7
7 14 0.00 40 15.16 279 2 8

Cycle 58 GMT 3/ 8/2020 13:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 33 15.15 432 2 2
2 7 2010.56 36 14.95 2900 2 2
3 13 1504.12 19 14.96 2312 2 3
4 13 989.60 19 15.01 1655 2 3
5 13 278.44 19 15.16 684 2 2
6 8 0.00 155 15.19 284 2 6
7 14 0.00 40 15.16 282 2 10

Cycle 57 GMT 24/ 7/2020 16: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 33 15.16 429 2 2
2 7 2011.20 36 14.95 2907 2 2
3 13 1505.40 19 14.96 2313 2 3
4 13 988.04 19 15.01 1657 2 3
5 13 306.44 19 15.16 717 2 2
6 8 0.16 155 15.19 284 2 6

Cycle 56 GMT 14/ 7/2020 18: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 33 15.16 440 2 2
2 7 2009.08 36 14.95 2915 2 2
3 13 1492.92 19 14.96 2308 2 3
4 13 989.76 19 15.02 1661 2 3
5 13 280.92 19 15.16 685 2 2
6 8 0.36 155 15.19 280 2 6
7 14 0.36 40 15.17 279 2 6

Cycle 55 GMT 4/ 7/2020 20: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 33 15.16 434 2 2
2 7 2010.00 36 14.95 2914 2 3
3 13 1500.16 19 14.96 2312 2 3
4 13 985.16 19 15.02 1652 2 3
5 13 267.96 19 15.17 672 2 2
6 8 0.04 155 15.20 287 2 5

Cycle 54 GMT 24/ 6/2020 22:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 33 15.17 442 2 2
2 7 2010.20 36 14.96 2900 2 2
3 13 1491.44 19 14.98 2294 2 2
4 13 971.92 19 15.03 1636 2 3
5 13 274.60 19 15.18 677 2 2
6 8 0.08 155 15.20 285 2 6

Cycle 53 GMT 15/ 6/2020 0:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 33 15.17 436 2 2
2 7 2003.68 36 14.96 2903 2 3
3 13 1497.12 19 14.98 2308 2 3
4 13 980.68 19 15.04 1640 2 3
5 13 283.44 19 15.18 685 2 2
6 8 0.08 155 15.21 282 2 5

Cycle 52 GMT 5/ 6/2020 2:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 33 15.17 428 2 2
2 7 2010.84 36 14.97 2905 2 2
3 13 1513.52 19 14.98 2318 2 3
4 13 1012.12 19 15.03 1684 2 3
5 13 305.16 19 15.18 716 2 3
6 13 24.76 19 15.23 321 2 2
7 8 0.36 155 15.21 280 2 6

Cycle 51 GMT 26/ 5/2020 5: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 33 15.17 410 2 2
2 7 2004.48 36 14.97 2895 2 2
3 13 1474.08 19 14.99 2272 2 3
4 13 964.72 19 15.05 1627 2 3
5 13 255.92 19 15.20 656 2 2
6 13 20.92 19 15.24 319 2 2
7 8 0.08 155 15.21 284 2 4
8 14 0.08 40 15.19 282 2 7

Cycle 50 GMT 16/ 5/2020 7:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 33 15.18 433 2 2
2 7 2008.64 36 14.97 2908 2 3
3 13 1501.28 19 14.99 2306 2 3
4 13 965.40 19 15.05 1631 2 3
5 13 264.92 19 15.20 671 2 2
6 13 26.00 19 15.24 330 2 2
7 8 0.08 155 15.21 287 2 6
8 14 0.08 40 15.19 281 2 9

Cycle 49 GMT 6/ 5/2020 9:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 33 15.18 428 2 2
2 7 2009.92 36 14.98 2908 2 3
3 13 1497.60 19 14.99 2304 2 3
4 13 991.52 19 15.05 1662 2 3
5 13 293.24 19 15.19 709 2 3
6 13 26.20 19 15.24 333 2 2
7 8 0.00 155 15.21 286 2 6

Cycle 48 GMT 26/ 4/2020 11:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 33 15.18 428 2 2
2 7 2009.20 36 14.98 2905 2 2
3 13 1370.44 19 15.00 2144 2 3
4 13 897.92 19 15.06 1535 2 3
5 13 224.92 19 15.20 606 2 2
6 8 0.04 155 15.22 284 2 4

Cycle 47 GMT 16/ 4/2020 13:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 33 15.18 400 2 2
2 7 2007.00 37 14.97 2897 2 3
3 13 1506.20 19 14.99 2314 2 3
4 13 989.32 19 15.05 1663 2 3
5 13 277.44 19 15.20 678 2 2
6 13 25.16 19 15.24 326 2 2
7 8 0.12 155 15.22 280 2 6

Cycle 46 GMT 6/ 4/2020 15:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 33 15.18 427 2 2
2 7 2007.76 36 14.98 2903 2 2
3 13 1496.04 19 15.00 2302 2 3
4 13 977.68 19 15.06 1640 2 3
5 13 267.56 19 15.21 664 2 2
6 13 50.16 19 15.24 359 2 2
7 8 0.04 155 15.22 279 2 5
8 14 0.04 40 15.20 276 2 6

Cycle 45 GMT 27/ 3/2020 18: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 33 15.19 426 2 2
2 7 2009.16 37 14.99 2905 2 2
3 13 1504.40 19 15.00 2307 2 3
4 13 995.96 19 15.06 1658 2 3
5 13 282.44 19 15.20 684 2 2
6 13 46.96 19 15.24 354 2 2
7 8 0.16 155 15.22 282 2 7

Cycle 44 GMT 17/ 3/2020 20:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 33 15.19 432 2 2
2 7 2004.40 37 15.00 2894 2 2
3 13 1512.80 19 15.01 2326 2 3
4 13 988.24 19 15.06 1658 2 3
5 13 273.92 19 15.21 672 2 2
6 13 21.08 19 15.25 322 2 2
7 8 0.00 155 15.23 283 2 7

Cycle 43 GMT 7/ 3/2020 22:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 33 15.20 425 2 2
2 7 2004.72 36 15.00 2896 2 2
3 13 1510.04 19 15.01 2321 2 3
4 13 994.56 19 15.06 1668 2 3
5 13 276.24 19 15.21 676 2 2
6 13 21.04 19 15.25 321 2 2
7 8 0.20 155 15.23 281 2 5

Cycle 42 GMT 27/ 2/2020 1: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 33 15.21 424 2 2
2 7 2005.84 36 15.01 2897 2 2
3 13 1495.00 19 15.02 2301 2 3
4 13 984.88 19 15.08 1641 2 3
5 13 253.64 19 15.23 641 2 2
6 13 20.40 19 15.26 316 2 2
7 8 0.12 155 15.24 281 2 7

Cycle 41 GMT 17/ 2/2020 3:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 33 15.21 423 2 2
2 7 2008.24 37 15.00 2901 2 2
3 13 1488.92 19 15.01 2292 2 2
4 13 973.12 19 15.08 1632 2 3
5 13 260.24 19 15.22 653 2 2
6 8 0.16 155 15.25 279 2 5

Cycle 40 GMT 7/ 2/2020 5:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 33 15.21 421 2 2
2 7 2007.00 36 15.01 2895 2 3
3 13 1493.16 19 15.03 2298 2 3
4 13 977.04 19 15.09 1627 2 3
5 13 268.76 19 15.23 662 2 2
6 13 20.64 19 15.27 321 2 2
7 8 0.04 155 15.24 282 2 6

Cycle 39 GMT 28/ 1/2020 8: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 32 15.22 428 2 2
2 7 2003.16 36 15.01 2899 2 2
3 13 1500.52 19 15.02 2314 2 3
4 13 997.20 19 15.08 1661 2 3
5 13 290.28 19 15.23 693 2 2
6 13 19.96 19 15.27 319 2 2
7 8 0.16 155 15.24 283 2 4

Cycle 38 GMT 18/ 1/2020 10:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 32 15.22 427 2 2
2 7 2007.76 36 15.01 2901 2 3
3 13 1492.40 19 15.03 2304 2 3
4 13 994.08 19 15.08 1659 2 3
5 13 285.00 19 15.23 687 2 2
6 8 0.00 155 15.26 282 2 5

Cycle 37 GMT 8/ 1/2020 12:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 15.22 430 2 2
2 7 2008.60 36 15.01 2903 2 2
3 13 1497.20 19 15.02 2303 2 3
4 13 976.24 19 15.09 1639 2 3
5 13 253.52 19 15.24 642 2 2
6 8 0.00 155 15.26 281 2 6

Cycle 36 GMT 29/12/2019 14:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 32 15.21 437 2 2
2 7 2005.48 36 15.01 2909 2 3
3 13 1493.08 19 15.03 2307 2 3
4 13 970.84 19 15.09 1636 2 3
5 13 257.20 19 15.24 653 2 2
6 8 0.12 155 15.26 286 2 5

Cycle 35 GMT 19/12/2019 17:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 32 15.21 432 2 2
2 7 2004.60 37 15.00 2899 2 2
3 13 1489.08 19 15.03 2283 2 3
4 13 835.96 19 15.13 1455 2 3
5 13 297.44 19 15.23 716 2 3
6 8 0.00 155 15.26 292 2 5

Cycle 34 GMT 9/12/2019 19:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 32 15.30 420 2 2
2 7 2009.72 36 14.99 2905 2 2
3 13 1375.32 19 15.03 2152 2 3
4 13 887.68 19 15.10 1521 2 3
5 13 213.20 19 15.23 596 2 2
6 8 0.04 155 15.24 287 2 5

Cycle 33 GMT 29/11/2019 21:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 15.26 431 2 2
2 3 1026.08 1 15.32 1726 2 2
3 7 1071.56 36 15.34 1690 2 2
4 13 1009.04 19 15.30 1622 2 2
5 13 858.52 19 15.28 1427 2 3
6 13 61.64 19 15.36 374 2 2
7 8 0.16 155 15.34 280 2 5

Cycle 32 GMT 19/11/2019 22:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 32 15.24 433 2 2
2 7 1465.32 36 15.16 2245 2 2
3 13 1335.40 19 15.15 2095 2 3
4 13 992.32 19 15.17 1651 2 3
5 13 121.40 19 15.32 466 2 2
6 8 0.04 155 15.31 290 2 5

Cycle 31 GMT 9/11/2019 22:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 32 15.24 429 2 2
2 7 2006.60 36 15.02 2898 2 2
3 13 1486.08 19 15.04 2295 2 3
4 13 961.36 19 15.11 1613 2 3
5 13 152.88 19 15.28 509 2 2
6 8 0.16 155 15.27 289 2 5

Cycle 30 GMT 31/10/2019 1: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 32 15.24 448 2 2
2 7 2006.48 36 15.03 2894 2 2
3 13 1483.16 19 15.06 2287 2 3
4 13 966.64 19 15.12 1619 2 3
5 13 129.52 19 15.29 473 2 2
6 8 0.20 155 15.28 285 2 3

Cycle 29 GMT 21/10/2019 3:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 32 15.23 420 2 2
2 7 2021.68 36 15.03 2912 2 3
3 13 1485.72 19 15.05 2287 2 3
4 13 964.52 19 15.12 1622 2 3
5 13 134.24 19 15.29 478 2 2
6 8 0.00 165 15.28 288 2 6

Cycle 28 GMT 11/10/2019 5:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 15.25 435 2 2
2 7 2001.24 36 15.04 2889 2 2
3 13 1491.44 19 15.06 2298 2 3
4 13 837.92 19 15.16 1439 2 3
5 13 171.36 19 15.29 528 2 2
6 8 0.12 165 15.29 284 2 4
7 14 0.12 75 15.25 280 2 13

Cycle 27 GMT 1/10/2019 7:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 32 15.25 431 2 2
2 7 2008.00 36 15.04 2894 2 2
3 13 1491.68 19 15.06 2296 2 3
4 13 968.88 19 15.13 1629 2 3
5 13 139.80 19 15.29 492 2 2
6 8 -0.04 165 15.29 289 2 5

Cycle 26 GMT 21/ 9/2019 10: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 32 15.24 434 2 2
2 7 2005.40 36 15.04 2901 2 2
3 13 1496.40 19 15.06 2307 2 3
4 13 978.68 19 15.13 1641 2 3
5 13 145.28 19 15.30 496 2 2
6 8 0.24 165 15.29 289 2 7

Cycle 25 GMT 11/ 9/2019 12: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 32 15.25 427 2 2
2 7 2003.92 36 15.04 2897 2 2
3 13 1496.84 19 15.06 2313 2 3
4 13 971.92 19 15.13 1629 2 3
5 13 254.52 19 15.27 647 2 2
6 8 0.16 165 15.29 290 2 6

Cycle 24 GMT 1/ 9/2019 14:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 32 15.25 434 2 2
2 7 2012.36 37 15.04 2910 2 2
3 13 1497.56 19 15.06 2301 2 3
4 13 975.28 19 15.13 1639 2 3
5 13 149.40 19 15.30 496 2 2
6 8 0.08 165 15.29 286 2 7

Cycle 23 GMT 22/ 8/2019 16:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 32 15.24 439 2 2
2 7 2006.56 36 15.04 2902 2 2
3 13 1493.40 19 15.07 2298 2 3
4 13 985.76 19 15.13 1648 2 3
5 13 155.48 19 15.30 509 2 2
6 8 0.28 165 15.30 288 2 5

Cycle 22 GMT 12/ 8/2019 18:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 32 15.26 441 2 2
2 7 2006.88 36 15.05 2902 2 3
3 13 1487.84 19 15.07 2301 2 3
4 13 985.80 19 15.14 1649 2 3
5 13 283.28 19 15.28 690 2 2
6 8 0.08 165 15.30 293 2 5
7 14 0.08 75 15.27 289 2 9

Cycle 21 GMT 2/ 8/2019 20:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 32 15.26 437 2 2
2 7 2007.76 36 15.05 2904 2 2
3 13 1500.12 19 15.07 2314 2 3
4 13 971.08 19 15.14 1631 2 3
5 13 139.28 19 15.31 496 2 2
6 8 0.20 165 15.30 293 2 5

Cycle 20 GMT 23/ 7/2019 23:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 32 15.27 435 2 2
2 7 2011.08 36 15.05 2912 2 2
3 13 1492.96 19 15.08 2307 2 3
4 13 973.52 19 15.14 1633 2 3
5 13 247.20 19 15.29 644 2 2
6 8 -0.04 165 15.30 292 2 8

Cycle 19 GMT 14/ 7/2019 1:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 32 15.26 426 2 2
2 7 2004.24 36 15.05 2904 2 2
3 13 1482.00 19 15.08 2276 2 2
4 13 827.04 19 15.18 1435 2 2
5 13 155.84 19 15.31 515 2 2
6 8 0.04 165 15.31 289 2 6

Cycle 18 GMT 4/ 7/2019 3:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 31 15.26 434 2 2
2 7 2002.72 37 15.05 2900 2 3
3 13 1498.20 19 15.09 2309 2 3
4 13 971.04 19 15.15 1628 2 3
5 13 135.20 19 15.32 482 2 2
6 8 0.08 165 15.31 284 2 4
7 14 0.08 75 15.28 280 2 9

Cycle 17 GMT 24/ 6/2019 5:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 31 15.27 447 2 2
2 7 2009.60 36 15.05 2907 2 2
3 13 1487.92 19 15.09 2287 2 3
4 13 960.64 19 15.15 1620 2 3
5 13 128.96 19 15.32 473 2 2
6 8 0.12 165 15.32 283 2 5
7 14 0.12 75 15.29 280 2 9

Cycle 16 GMT 14/ 6/2019 7:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 15.26 426 2 2
2 7 2009.08 36 15.05 2909 2 2
3 13 1489.00 19 15.09 2297 2 2
4 13 970.16 19 15.15 1638 2 3
5 13 237.88 19 15.30 635 2 2
6 8 0.08 165 15.31 291 2 6

Cycle 15 GMT 4/ 6/2019 9:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 31 15.27 439 2 2
2 7 2004.08 36 15.06 2901 2 2
3 13 1489.44 19 15.09 2295 2 3
4 13 960.40 19 15.15 1626 2 3
5 13 229.00 19 15.30 622 2 2
6 8 0.24 165 15.31 292 2 5
7 14 0.24 75 15.28 287 2 10

Cycle 14 GMT 25/ 5/2019 11:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 31 15.27 415 2 2
2 3 1015.64 1 15.34 1763 2 2
3 7 2004.04 36 15.06 2905 2 2
4 13 1336.44 19 15.12 2113 2 3
5 13 852.64 19 15.18 1480 2 3
6 13 160.80 19 15.32 528 2 2
7 8 0.00 165 15.32 289 2 7

Cycle 13 GMT 15/ 5/2019 13:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 31 15.28 434 2 2
2 7 2007.20 36 15.06 2908 2 3
3 13 1345.96 19 15.12 2121 2 2
4 13 866.76 19 15.18 1502 2 3
5 13 154.64 19 15.32 516 2 2
6 8 0.04 165 15.32 289 2 6
7 14 0.04 75 15.29 283 2 9

Cycle 12 GMT 5/ 5/2019 15:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 31 15.28 432 2 2
2 7 2003.28 37 15.06 2904 2 2
3 13 1344.60 19 15.12 2131 2 2
4 13 1002.76 19 15.15 1685 2 3
5 13 72.12 19 15.34 404 2 2
6 8 0.00 165 15.32 290 2 5

Cycle 11 GMT 25/ 4/2019 17:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 31 15.29 425 2 2
2 7 2001.84 36 15.06 2901 2 2
3 13 1475.16 19 15.10 2284 2 3
4 13 938.84 19 15.17 1597 2 3
5 13 228.72 19 15.31 625 2 2
6 8 0.24 165 15.32 294 2 5

Cycle 10 GMT 15/ 4/2019 20:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 31 15.29 425 2 2
2 7 2002.48 36 15.07 2899 2 3
3 13 1462.28 19 15.11 2261 2 3
4 13 795.08 19 15.21 1397 2 3
5 13 130.96 19 15.33 487 2 2
6 8 0.04 165 15.33 291 2 4

Cycle 9 GMT 5/ 4/2019 22:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 15.29 423 2 2
2 7 2003.80 36 15.07 2901 2 2
3 13 1356.16 19 15.13 2124 2 3
4 13 1011.36 19 15.15 1683 2 3
5 13 137.44 19 15.33 491 2 2
6 8 0.20 165 15.33 291 2 5

Cycle 8 GMT 27/ 3/2019 0:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 31 15.30 412 2 2
2 7 2003.32 36 15.09 2896 2 2
3 13 1481.64 19 15.12 2283 2 2
4 13 807.68 19 15.22 1404 2 2
5 13 299.56 19 15.31 706 2 2
6 13 46.24 19 15.35 358 2 2
7 8 0.08 165 15.32 288 2 5

Cycle 7 GMT 17/ 3/2019 2:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 31 15.29 423 2 2
2 3 1018.36 1 15.38 1749 2 2
3 7 2001.48 36 15.08 2896 2 3
4 13 1482.40 19 15.13 2288 2 3
5 13 800.60 19 15.22 1397 2 2
6 13 64.72 19 15.36 385 2 2
7 13 36.36 19 15.36 341 2 2
8 8 0.12 165 15.33 284 2 4

Cycle 6 GMT 7/ 3/2019 4:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 30 15.30 431 2 2
2 3 1037.00 1 15.34 1773 2 2
3 7 2004.72 38 15.08 2899 2 2
4 13 1317.48 18 15.15 2085 2 2
5 13 818.48 18 15.22 1430 2 3
6 13 136.96 18 15.34 490 2 2
7 13 22.28 18 15.36 329 2 2
8 8 0.04 165 15.33 288 2 4

Cycle 5 GMT 25/ 2/2019 6:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 31 15.31 433 2 2
2 3 953.16 -1 15.59 0 2 2
3 3 1017.68 1 15.38 1753 2 2
4 7 2002.08 38 15.08 2893 2 2
5 13 1312.72 18 15.15 2072 2 3
6 13 794.44 18 15.22 1389 2 3
7 13 70.20 18 15.36 394 2 2
8 8 0.12 165 15.34 288 2 6

Cycle 4 GMT 15/ 2/2019 8:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 15.30 415 2 2
2 7 1513.88 38 15.20 2272 2 2
3 13 1200.28 18 15.20 1907 2 2
4 13 688.40 18 15.26 1241 2 2
5 13 45.40 18 15.37 359 2 2
6 8 0.08 165 15.35 283 2 5

Cycle 3 GMT 14/ 2/2019 8:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 15.29 422 2 2
2 7 1507.92 74 15.11 2251 2 3
3 13 122.96 18 15.36 464 2 2
4 8 0.00 240 15.34 282 2 17

Cycle 2 GMT 13/ 2/2019 8:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 29 15.32 427 2 2
2 7 1525.88 74 15.10 2278 2 3
3 13 125.76 18 15.35 469 2 2
4 8 0.12 240 15.33 285 2 8

Cycle 1 GMT 12/ 2/2019 9: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 29 15.50 387 2 3
2 7 1003.92 74 15.24 1615 2 2
3 8 0.12 240 15.37 292 2 9

Cycle 0 GMT 11/ 2/2019 22:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 28 15.62 403 2 3
2 7 122.20 74 15.60 405 2 2
3 8 0.12 240 15.56 239 2 7