SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 28 | 15.20 | 444 | 2 | 2 |
2 | 3 | 1019.76 | 1 | 15.22 | 1877 | 2 | 3 |
3 | 7 | 2007.68 | 30 | 14.96 | 3095 | 2 | 3 |
4 | 13 | 1584.92 | 17 | 14.99 | 2555 | 2 | 4 |
5 | 13 | 993.88 | 17 | 15.07 | 1760 | 2 | 6 |
6 | 13 | 561.16 | 17 | 15.17 | 1152 | 2 | 7 |
7 | 13 | 66.52 | 17 | 15.35 | 392 | 2 | 5 |
8 | 13 | 15.92 | 17 | 15.43 | 311 | 2 | 4 |
9 | 8 | -0.04 | 165 | 15.43 | 278 | 2 | 10 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 28 | 15.20 | 439 | 2 | 2 |
2 | 7 | 2003.36 | 30 | 14.94 | 3075 | 2 | 3 |
3 | 13 | 1576.08 | 17 | 14.96 | 2541 | 2 | 4 |
4 | 13 | 986.16 | 17 | 15.04 | 1747 | 2 | 6 |
5 | 13 | 546.68 | 17 | 15.13 | 1129 | 2 | 7 |
6 | 13 | 55.36 | 17 | 15.25 | 371 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.23 | 277 | 2 | 9 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 28 | 15.20 | 443 | 2 | 2 |
2 | 7 | 2003.20 | 30 | 14.95 | 3091 | 2 | 3 |
3 | 13 | 1461.84 | 17 | 14.99 | 2383 | 2 | 4 |
4 | 13 | 1031.92 | 17 | 15.03 | 1816 | 2 | 6 |
5 | 13 | 479.80 | 17 | 15.15 | 1027 | 2 | 7 |
6 | 13 | 42.80 | 17 | 15.26 | 350 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.24 | 275 | 2 | 8 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 27 | 15.20 | 440 | 2 | 2 |
2 | 3 | 1023.56 | 1 | 15.23 | 1878 | 2 | 4 |
3 | 7 | 2004.40 | 30 | 14.95 | 3074 | 2 | 3 |
4 | 13 | 1448.60 | 18 | 14.99 | 2369 | 2 | 4 |
5 | 13 | 1015.40 | 18 | 15.04 | 1791 | 2 | 6 |
6 | 13 | 424.36 | 18 | 15.17 | 935 | 2 | 6 |
7 | 13 | 27.24 | 18 | 15.26 | 325 | 2 | 4 |
8 | 8 | 0.00 | 165 | 15.23 | 277 | 2 | 11 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 26 | 15.20 | 440 | 2 | 2 |
2 | 3 | 1054.12 | 2 | 15.20 | 1921 | 2 | 4 |
3 | 7 | 2004.16 | 30 | 14.96 | 3080 | 2 | 4 |
4 | 13 | 1461.60 | 18 | 14.99 | 2377 | 2 | 5 |
5 | 13 | 1033.92 | 18 | 15.04 | 1805 | 2 | 6 |
6 | 13 | 455.08 | 18 | 15.16 | 981 | 2 | 7 |
7 | 13 | 38.12 | 18 | 15.26 | 336 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.23 | 274 | 2 | 9 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 23 | 15.22 | 428 | 2 | 2 |
2 | 10 | 1024.24 | 2 | 15.17 | 1833 | 2 | 3 |
3 | 3 | 1041.88 | 1 | 15.21 | 1896 | 2 | 4 |
4 | 7 | 2004.28 | 31 | 14.96 | 3049 | 2 | 4 |
5 | 13 | 1567.96 | 18 | 14.98 | 2521 | 2 | 5 |
6 | 13 | 968.60 | 18 | 15.06 | 1711 | 2 | 6 |
7 | 13 | 516.24 | 18 | 15.14 | 1072 | 2 | 7 |
8 | 13 | 22.20 | 18 | 15.27 | 319 | 2 | 4 |
9 | 8 | 0.00 | 165 | 15.24 | 275 | 2 | 10 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 26 | 15.21 | 442 | 2 | 2 |
2 | 7 | 1511.44 | 74 | 14.94 | 2402 | 2 | 5 |
3 | 13 | 131.64 | 18 | 15.26 | 479 | 2 | 5 |
4 | 8 | 0.00 | 165 | 15.25 | 268 | 2 | 7 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 28 | 15.20 | 422 | 2 | 2 |
2 | 3 | 944.28 | -1 | 15.50 | 0 | 2 | 2 |
3 | 7 | 1507.52 | 74 | 14.95 | 2393 | 2 | 5 |
4 | 13 | 218.68 | 18 | 15.24 | 609 | 2 | 6 |
5 | 8 | 0.12 | 165 | 15.25 | 270 | 2 | 11 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 24 | 15.25 | 430 | 2 | 2 |
2 | 10 | 1014.12 | 2 | 15.19 | 1809 | 2 | 3 |
3 | 7 | 1510.12 | 74 | 14.96 | 2392 | 2 | 5 |
4 | 13 | 130.08 | 18 | 15.26 | 473 | 2 | 5 |
5 | 8 | 0.04 | 165 | 15.26 | 263 | 2 | 8 |
6 | 14 | 0.04 | 75 | 15.23 | 259 | 2 | 14 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 23 | 15.41 | 385 | 2 | 3 |
2 | 10 | 1046.76 | 3 | 15.23 | 1849 | 2 | 3 |
3 | 3 | 1021.52 | 1 | 15.26 | 1869 | 2 | 4 |
4 | 7 | 998.56 | 74 | 15.10 | 1710 | 2 | 7 |
5 | 8 | 0.08 | 165 | 15.29 | 269 | 2 | 8 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 22 | 15.54 | 381 | 2 | 3 |
2 | 7 | 120.28 | 74 | 15.51 | 387 | 2 | 3 |
3 | 8 | 0.20 | 229 | 15.47 | 218 | 2 | 245 |