SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8789 WMO= 2903424


Cycle 242 GMT 13/12/2024 6:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 30 14.64 473 3 3
2 7 2008.76 37 14.39 3157 2 3
3 13 1429.80 19 14.43 2401 2 3
4 13 854.72 19 14.50 1610 2 4
5 13 428.52 19 14.60 984 2 4
6 13 61.08 19 14.70 395 3 3
7 8 0.12 165 14.68 297 3 3

Cycle 241 GMT 3/12/2024 11:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 30 14.66 480 3 3
2 7 2008.56 37 14.38 3151 2 3
3 13 1297.04 19 14.45 2226 2 4
4 13 866.84 19 14.49 1623 2 4
5 13 433.32 19 14.58 1001 2 4
6 13 50.56 19 14.70 381 3 3
7 8 0.08 165 14.68 299 3 3

Cycle 240 GMT 23/11/2024 15:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 30 14.65 463 3 3
2 7 2004.52 37 14.38 3152 2 3
3 13 1322.16 19 14.45 2262 2 3
4 13 793.96 19 14.50 1525 2 4
5 13 386.00 19 14.60 926 2 4
6 13 56.16 19 14.70 390 3 3
7 8 0.12 165 14.68 296 3 3

Cycle 239 GMT 13/11/2024 20:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 14.66 455 3 3
2 7 2006.80 37 14.39 3146 2 3
3 13 1404.64 19 14.44 2370 2 3
4 13 843.12 19 14.50 1588 2 4
5 13 399.96 19 14.60 941 2 4
6 13 55.40 19 14.70 395 3 3
7 8 0.00 165 14.68 297 3 4

Cycle 238 GMT 4/11/2024 0:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 30 14.66 473 3 3
2 7 2007.32 37 14.38 3155 2 3
3 13 1421.16 19 14.44 2379 2 3
4 13 844.20 19 14.50 1585 2 4
5 13 290.04 19 14.64 767 3 3
6 13 42.28 19 14.71 364 3 3
7 8 0.08 165 14.69 292 3 3
8 14 0.08 30 14.67 291 3 3

Cycle 237 GMT 25/10/2024 5: 5: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 31 14.65 454 3 3
2 7 2008.20 38 14.39 3157 2 3
3 13 1308.80 19 14.45 2231 2 3
4 13 781.36 19 14.51 1509 2 4
5 13 258.96 19 14.65 720 2 4
6 13 33.88 19 14.71 346 3 3
7 8 0.12 165 14.69 289 3 3

Cycle 236 GMT 15/10/2024 9:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 31 14.66 463 3 3
2 7 2004.32 37 14.38 3163 2 3
3 13 1434.08 19 14.44 2395 2 3
4 13 864.36 19 14.50 1616 2 4
5 13 424.12 19 14.60 979 2 4
6 13 46.68 19 14.70 371 3 3
7 8 0.08 165 14.68 291 3 3

Cycle 235 GMT 5/10/2024 13:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 30 14.65 452 3 3
2 7 2011.60 37 14.39 3163 2 3
3 13 1568.12 19 14.42 2597 2 3
4 13 971.52 19 14.47 1773 2 4
5 13 407.52 19 14.61 945 2 3
6 13 42.20 19 14.71 370 3 3
7 13 22.64 19 14.71 331 3 3
8 8 0.20 165 14.68 289 3 3

Cycle 234 GMT 25/ 9/2024 18:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 30 14.65 454 3 3
2 7 2005.12 37 14.39 3168 2 3
3 13 1432.92 19 14.44 2413 2 3
4 13 875.88 19 14.49 1648 2 4
5 13 444.52 19 14.59 1005 2 4
6 13 38.08 19 14.71 358 3 3
7 13 17.52 19 14.71 323 3 3
8 8 0.12 165 14.68 294 3 3

Cycle 233 GMT 15/ 9/2024 23: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 30 14.65 461 3 3
2 7 2003.08 37 14.40 3164 2 3
3 13 1429.16 19 14.44 2406 2 3
4 13 870.64 19 14.50 1628 2 4
5 13 444.12 19 14.59 1013 2 4
6 13 34.04 19 14.71 359 3 3
7 13 21.12 19 14.71 337 3 3
8 8 0.04 165 14.68 299 3 3

Cycle 232 GMT 6/ 9/2024 3:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 14.66 462 3 3
2 7 2009.64 37 14.39 3169 2 3
3 13 1429.48 19 14.44 2407 2 3
4 13 851.32 19 14.50 1609 2 4
5 13 418.52 19 14.60 983 2 4
6 13 44.84 19 14.71 383 3 3
7 13 17.12 19 14.71 332 3 3
8 8 0.04 165 14.68 305 3 4

Cycle 231 GMT 27/ 8/2024 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 30 14.67 458 3 3
2 7 2009.00 37 14.39 3158 2 3
3 13 1414.72 19 14.45 2380 2 3
4 13 959.32 19 14.48 1759 2 4
5 13 383.28 19 14.62 923 2 4
6 13 47.48 19 14.71 376 3 3
7 13 18.60 19 14.71 325 3 3
8 8 0.12 165 14.69 295 3 3

Cycle 230 GMT 17/ 8/2024 12:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 30 14.66 461 3 3
2 7 2009.16 37 14.39 3152 2 3
3 13 1431.12 19 14.44 2414 2 3
4 13 859.96 19 14.50 1618 2 4
5 13 307.28 19 14.64 798 2 3
6 13 38.16 19 14.72 359 3 3
7 13 11.24 19 14.72 316 3 3
8 8 0.16 165 14.69 298 3 3

Cycle 229 GMT 7/ 8/2024 17: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 30 14.65 462 3 3
2 3 1012.92 1 14.76 1917 2 3
3 7 2003.88 37 14.40 3139 2 3
4 13 1438.00 19 14.45 2416 2 3
5 13 857.64 19 14.51 1620 2 4
6 13 419.76 19 14.60 985 2 4
7 13 31.28 19 14.72 359 3 3
8 13 16.40 19 14.72 329 3 3
9 8 0.20 165 14.69 303 3 3

Cycle 228 GMT 28/ 7/2024 21:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 30 14.65 464 3 3
2 7 2003.44 37 14.39 3160 2 3
3 13 1428.48 19 14.44 2403 2 3
4 13 853.92 19 14.51 1605 2 4
5 13 299.40 19 14.65 787 3 4
6 13 34.68 19 14.72 358 3 3
7 13 12.04 19 14.72 325 3 3
8 8 -0.08 165 14.69 304 3 4

Cycle 227 GMT 19/ 7/2024 2:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 30 14.66 459 3 3
2 7 2007.20 37 14.39 3155 2 3
3 13 1407.92 19 14.44 2392 2 3
4 13 841.04 19 14.51 1598 2 4
5 13 407.92 19 14.61 969 2 4
6 13 26.88 19 14.72 348 3 3
7 13 7.32 19 14.72 319 3 3
8 8 0.16 165 14.68 302 3 3

Cycle 226 GMT 9/ 7/2024 6:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 14.67 461 3 3
2 7 2006.00 38 14.39 3160 2 3
3 13 1419.68 19 14.44 2393 2 3
4 13 826.80 19 14.51 1583 2 4
5 13 409.16 19 14.60 977 2 4
6 13 31.36 19 14.72 367 3 3
7 13 10.40 19 14.72 328 3 3
8 8 0.08 165 14.68 309 3 3

Cycle 225 GMT 29/ 6/2024 11:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 30 14.66 462 3 3
2 7 2009.40 37 14.39 3162 2 3
3 13 1435.64 19 14.44 2418 2 3
4 13 866.96 19 14.50 1623 2 4
5 13 311.64 19 14.64 825 2 4
6 13 35.88 19 14.72 365 3 3
7 8 0.16 165 14.69 305 3 3

Cycle 224 GMT 19/ 6/2024 15:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.66 463 3 3
2 7 2008.88 37 14.40 3154 2 3
3 13 1437.92 19 14.44 2414 2 3
4 13 878.32 19 14.50 1641 2 4
5 13 438.08 19 14.60 1009 2 4
6 13 27.36 19 14.72 347 3 3
7 8 0.24 165 14.69 302 3 3

Cycle 223 GMT 9/ 6/2024 20:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 14.67 464 3 3
2 7 2004.20 37 14.39 3146 2 3
3 13 1425.16 19 14.45 2400 2 3
4 13 864.28 19 14.51 1623 2 4
5 13 310.76 19 14.64 804 3 4
6 13 33.28 19 14.72 358 3 3
7 8 0.12 165 14.69 304 3 3

Cycle 222 GMT 31/ 5/2024 0:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 30 14.67 467 3 3
2 7 2004.04 37 14.39 3152 2 3
3 13 1321.16 19 14.46 2257 2 3
4 13 798.56 19 14.52 1527 2 4
5 13 383.32 19 14.62 907 2 4
6 13 48.80 19 14.72 374 3 3
7 8 0.08 165 14.70 295 3 5

Cycle 221 GMT 21/ 5/2024 5:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 30 14.67 466 3 3
2 7 2002.76 37 14.41 3160 2 3
3 13 1444.36 19 14.45 2433 2 3
4 13 998.84 19 14.48 1818 2 4
5 13 414.64 19 14.61 980 2 4
6 13 51.40 19 14.72 389 3 3
7 8 0.04 165 14.70 303 3 3

Cycle 220 GMT 11/ 5/2024 10: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 30 14.67 464 3 3
2 7 2012.72 38 14.40 3159 2 3
3 13 1421.72 19 14.45 2399 2 3
4 13 862.32 19 14.51 1623 2 4
5 13 323.40 19 14.65 828 2 4
6 13 38.96 19 14.73 367 3 3
7 8 0.16 165 14.70 304 3 3

Cycle 219 GMT 1/ 5/2024 14:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 30 14.67 469 3 3
2 7 2002.76 37 14.40 3153 2 3
3 13 1400.68 19 14.46 2368 2 3
4 13 843.40 19 14.52 1590 2 4
5 13 306.48 19 14.66 796 3 4
6 8 0.08 165 14.71 304 3 3

Cycle 218 GMT 21/ 4/2024 19:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 30 14.67 490 3 3
2 7 2006.68 38 14.40 3157 2 3
3 13 1416.76 19 14.45 2386 2 3
4 13 852.48 19 14.52 1596 2 4
5 13 409.12 19 14.62 959 2 4
6 8 0.04 165 14.71 299 3 3

Cycle 217 GMT 12/ 4/2024 0: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 14.67 471 3 3
2 7 2009.52 37 14.40 3154 2 3
3 13 1442.04 19 14.45 2418 2 3
4 13 1008.00 19 14.48 1835 2 4
5 13 422.40 19 14.62 987 2 4
6 13 23.44 19 14.74 337 3 3
7 8 0.04 165 14.70 303 3 3

Cycle 216 GMT 2/ 4/2024 4:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 14.67 464 3 3
2 7 2003.04 37 14.41 3156 2 3
3 13 1419.12 19 14.45 2388 2 3
4 13 843.40 19 14.52 1607 2 4
5 13 421.64 19 14.61 998 2 4
6 8 0.04 165 14.71 305 3 3

Cycle 215 GMT 23/ 3/2024 9:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 30 14.68 484 3 3
2 7 2008.60 38 14.40 3162 2 3
3 13 1311.76 19 14.47 2245 2 3
4 13 889.12 19 14.50 1674 2 4
5 13 438.04 19 14.61 1012 2 4
6 8 0.08 165 14.71 302 3 3

Cycle 214 GMT 13/ 3/2024 13:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 14.66 481 3 3
2 7 2003.60 38 14.40 3164 2 3
3 13 1307.56 19 14.47 2240 2 3
4 13 882.80 19 14.50 1672 2 4
5 13 322.48 19 14.65 832 2 4
6 8 0.04 165 14.71 302 3 3
7 14 0.04 30 14.69 301 3 3

Cycle 213 GMT 3/ 3/2024 18:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 30 14.68 465 3 3
2 7 2006.20 37 14.40 3152 2 3
3 13 1409.48 19 14.45 2379 2 3
4 13 836.12 19 14.52 1593 2 4
5 13 392.44 19 14.63 953 2 4
6 13 47.72 19 14.72 391 3 3
7 8 0.24 165 14.70 312 3 3

Cycle 212 GMT 22/ 2/2024 22:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 30 14.68 472 3 3
2 7 2003.56 37 14.40 3161 2 3
3 13 1406.52 19 14.46 2376 2 3
4 13 969.28 19 14.49 1778 2 4
5 13 383.76 19 14.63 928 2 4
6 8 0.00 165 14.72 302 3 3

Cycle 211 GMT 13/ 2/2024 3:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 30 14.68 470 3 3
2 7 2009.76 37 14.40 3159 2 3
3 13 1411.08 19 14.45 2381 2 3
4 13 839.92 19 14.52 1602 2 4
5 13 397.20 19 14.63 942 2 4
6 8 0.24 165 14.72 305 3 4
7 14 0.24 30 14.69 304 3 3

Cycle 210 GMT 3/ 2/2024 8: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 14.68 464 3 3
2 7 2008.52 37 14.41 3146 2 3
3 13 1442.92 19 14.45 2417 2 3
4 13 983.04 19 14.49 1780 2 4
5 13 391.68 19 14.63 925 2 4
6 8 0.00 165 14.72 301 3 3

Cycle 209 GMT 24/ 1/2024 10:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 30 14.68 488 3 3
2 7 2003.12 38 14.41 3153 2 3
3 13 1420.32 19 14.46 2390 2 3
4 13 844.92 19 14.53 1597 2 4
5 13 293.44 19 14.67 786 3 4
6 8 -0.04 165 14.72 303 3 3
7 14 -0.04 30 14.70 300 3 3

Cycle 208 GMT 14/ 1/2024 12:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 30 14.68 486 3 3
2 7 2002.80 37 14.41 3151 2 3
3 13 1424.92 19 14.46 2397 2 3
4 13 840.16 19 14.53 1593 2 4
5 13 404.40 19 14.63 966 2 4
6 13 51.92 19 14.73 396 3 3
7 8 0.08 165 14.71 309 3 3
8 14 0.08 30 14.68 308 3 3

Cycle 207 GMT 4/ 1/2024 14:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 14.67 489 3 3
2 7 2007.04 37 14.41 3172 2 3
3 13 1434.64 19 14.46 2419 2 3
4 13 864.44 19 14.52 1625 2 4
5 13 330.00 19 14.66 841 3 4
6 13 45.84 19 14.74 383 3 3
7 8 -0.12 165 14.71 308 3 3

Cycle 206 GMT 25/12/2023 16:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 30 14.67 464 3 3
2 7 2002.04 38 14.40 3159 2 3
3 13 1524.68 19 14.45 2532 2 3
4 13 809.96 19 14.54 1554 2 4
5 13 386.08 19 14.64 933 2 4
6 13 53.64 19 14.73 406 3 3
7 8 0.04 165 14.71 319 3 3

Cycle 205 GMT 15/12/2023 19: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 30 14.68 468 3 3
2 7 2011.92 37 14.40 3153 2 3
3 13 1436.40 19 14.46 2407 2 3
4 13 856.84 19 14.52 1617 2 4
5 13 409.08 19 14.63 959 2 4
6 13 53.64 19 14.73 386 3 3
7 8 0.20 165 14.71 302 3 4

Cycle 204 GMT 5/12/2023 21:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 30 14.69 459 3 3
2 7 2004.32 37 14.42 3154 2 3
3 13 1437.52 19 14.46 2414 2 3
4 13 859.84 19 14.53 1618 2 4
5 13 427.64 19 14.62 995 2 4
6 13 59.92 19 14.73 410 3 3
7 8 0.08 165 14.71 304 3 3

Cycle 203 GMT 25/11/2023 23:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.68 461 3 3
2 7 2007.52 37 14.41 3147 2 3
3 13 1302.16 19 14.48 2225 2 3
4 13 879.52 19 14.52 1637 2 4
5 13 336.40 19 14.65 844 2 4
6 13 53.08 19 14.74 379 3 3
7 8 0.24 165 14.71 293 3 3

Cycle 202 GMT 16/11/2023 1:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 14.69 464 3 3
2 7 2008.28 37 14.41 3152 2 3
3 13 1418.80 19 14.46 2382 2 3
4 13 850.04 19 14.53 1598 2 4
5 13 414.76 19 14.63 965 2 4
6 13 55.92 19 14.73 393 3 3
7 8 0.00 165 14.71 302 3 3

Cycle 201 GMT 6/11/2023 3:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 30 14.68 477 3 3
2 7 2003.84 37 14.41 3173 2 3
3 13 1423.32 19 14.47 2405 2 3
4 13 972.04 19 14.50 1777 2 4
5 13 396.72 19 14.64 951 2 4
6 13 50.52 19 14.74 396 3 3
7 8 0.16 165 14.72 303 3 3

Cycle 200 GMT 27/10/2023 6: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 30 14.69 464 3 3
2 7 2004.20 37 14.41 3172 2 3
3 13 1426.00 19 14.46 2414 2 3
4 13 963.08 19 14.50 1782 2 4
5 13 383.36 19 14.64 931 2 4
6 13 53.92 19 14.73 407 3 3
7 8 -0.04 165 14.72 313 3 3

Cycle 199 GMT 17/10/2023 8:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 14.69 475 3 3
2 7 2011.20 37 14.41 3179 2 3
3 13 1425.76 19 14.46 2415 2 3
4 13 853.96 19 14.53 1626 2 4
5 13 418.24 19 14.63 982 2 4
6 13 57.20 19 14.74 401 3 3
7 8 0.16 165 14.72 307 3 3

Cycle 198 GMT 7/10/2023 10:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 14.69 474 3 3
2 7 2011.60 38 14.41 3164 2 3
3 13 1432.60 19 14.46 2426 2 3
4 13 850.12 19 14.53 1614 2 4
5 13 304.52 19 14.67 807 3 3
6 13 36.96 19 14.75 374 3 3
7 13 12.60 19 14.75 327 3 3
8 8 0.08 165 14.72 308 3 4

Cycle 197 GMT 27/ 9/2023 12:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 14.69 470 3 3
2 7 2012.28 37 14.41 3173 2 3
3 13 1310.16 19 14.48 2258 2 3
4 13 880.28 19 14.52 1656 2 4
5 13 319.84 19 14.67 825 2 4
6 13 40.52 19 14.75 377 3 3
7 8 0.00 165 14.72 308 3 3

Cycle 196 GMT 17/ 9/2023 14:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 14.68 485 3 3
2 7 2007.60 38 14.41 3168 2 3
3 13 1427.92 19 14.47 2417 2 3
4 13 975.52 19 14.51 1791 2 4
5 13 374.24 19 14.65 927 2 4
6 13 46.72 19 14.75 382 3 3
7 13 12.32 19 14.75 330 3 3
8 8 0.08 165 14.72 308 3 3

Cycle 195 GMT 7/ 9/2023 16:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.69 470 3 3
2 7 2004.88 37 14.42 3152 2 3
3 13 1296.32 19 14.49 2229 2 3
4 13 869.04 19 14.53 1650 2 4
5 13 312.92 19 14.67 830 2 4
6 13 35.28 19 14.75 381 3 3
7 13 11.72 19 14.75 342 3 3
8 8 0.08 165 14.71 322 3 3

Cycle 194 GMT 28/ 8/2023 19: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 30 14.69 490 3 3
2 7 2010.52 37 14.42 3170 2 3
3 13 1436.08 19 14.47 2423 2 3
4 13 859.28 19 14.54 1636 2 4
5 13 419.36 19 14.63 1000 2 4
6 13 30.16 19 14.75 371 3 3
7 13 13.80 19 14.75 343 3 3
8 8 0.16 165 14.72 314 3 4

Cycle 193 GMT 18/ 8/2023 21:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 30 14.70 461 3 3
2 7 2002.72 37 14.42 3153 2 3
3 13 1423.88 19 14.47 2396 2 3
4 13 831.00 19 14.54 1589 2 4
5 13 385.28 19 14.65 936 2 4
6 13 26.16 19 14.75 355 3 3
7 13 10.52 19 14.75 332 3 3
8 8 -0.08 165 14.72 311 3 4

Cycle 192 GMT 8/ 8/2023 23:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 30 14.70 457 3 3
2 7 2009.28 37 14.42 3165 2 3
3 13 1438.20 19 14.47 2415 2 3
4 13 845.76 19 14.54 1610 2 4
5 13 279.92 19 14.69 775 3 4
6 13 29.08 19 14.76 365 3 3
7 8 0.04 165 14.73 311 3 3
8 14 0.04 30 14.70 306 3 3

Cycle 191 GMT 30/ 7/2023 1:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 30 14.70 460 3 3
2 7 2005.24 37 14.41 3154 2 3
3 13 1428.92 19 14.47 2408 2 3
4 13 841.68 19 14.54 1601 2 4
5 13 296.60 19 14.68 790 2 4
6 13 32.68 19 14.76 363 3 3
7 8 0.24 165 14.73 310 3 3

Cycle 190 GMT 20/ 7/2023 3:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 30 14.70 485 3 3
2 7 2003.88 37 14.42 3143 2 3
3 13 1422.16 19 14.48 2382 2 3
4 13 832.40 19 14.55 1568 2 4
5 13 397.56 19 14.65 939 2 4
6 13 26.20 19 14.76 343 3 3
7 8 0.04 165 14.73 302 3 3

Cycle 189 GMT 10/ 7/2023 5:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 30 14.70 464 3 3
2 7 2006.36 37 14.42 3168 2 3
3 13 1420.92 19 14.48 2392 2 3
4 13 973.72 19 14.51 1781 2 4
5 13 381.04 19 14.66 914 2 4
6 13 25.40 19 14.76 347 3 3
7 8 0.16 165 14.73 300 3 4

Cycle 188 GMT 30/ 6/2023 8: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 30 14.70 472 3 3
2 3 1015.08 1 14.81 1929 2 3
3 7 2010.32 37 14.41 3174 2 3
4 13 1430.48 19 14.47 2410 2 3
5 13 847.56 19 14.55 1595 2 4
6 13 408.12 19 14.65 957 2 4
7 13 26.80 19 14.76 347 3 3
8 8 0.16 165 14.73 299 3 3

Cycle 187 GMT 20/ 6/2023 10:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 30 14.70 462 3 3
2 7 2007.64 37 14.42 3156 2 3
3 13 1428.36 19 14.48 2417 2 3
4 13 845.56 19 14.55 1595 2 4
5 13 407.16 19 14.65 958 2 4
6 13 24.76 19 14.76 344 3 3
7 8 -0.04 165 14.73 303 3 3

Cycle 186 GMT 10/ 6/2023 12:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.70 480 3 3
2 7 2005.92 38 14.42 3167 2 3
3 13 1439.16 19 14.47 2412 2 3
4 13 869.08 19 14.54 1633 2 4
5 13 433.00 19 14.65 1004 2 4
6 13 27.04 19 14.77 342 3 3
7 8 0.16 165 14.74 303 3 3

Cycle 185 GMT 31/ 5/2023 14:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 30 14.70 495 3 3
2 7 2003.76 37 14.42 3182 2 3
3 13 1413.64 19 14.47 2398 2 3
4 13 839.88 19 14.55 1605 2 4
5 13 407.04 19 14.65 969 2 4
6 13 23.20 19 14.76 352 3 3
7 8 0.12 165 14.73 314 3 3

Cycle 184 GMT 21/ 5/2023 17: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 14.71 475 3 3
2 3 1012.52 1 14.82 1911 2 3
3 7 2005.72 37 14.42 3148 2 3
4 13 1424.08 19 14.47 2404 2 3
5 13 840.32 19 14.55 1595 2 4
6 13 407.04 19 14.65 964 2 4
7 13 22.44 19 14.77 335 3 3
8 8 -0.04 165 14.74 306 3 3

Cycle 183 GMT 11/ 5/2023 19:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 29 14.71 499 3 3
2 7 2013.64 38 14.42 3151 2 3
3 13 1433.44 19 14.47 2419 2 3
4 13 844.00 19 14.55 1594 2 4
5 13 397.36 19 14.66 948 2 4
6 8 0.04 165 14.75 309 3 3

Cycle 182 GMT 1/ 5/2023 21:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 27 14.71 462 3 3
2 10 1041.60 4 14.69 1916 3 3
3 7 2012.80 37 14.43 3152 2 3
4 13 1416.44 19 14.49 2393 2 3
5 13 839.16 19 14.56 1592 2 4
6 13 401.80 19 14.66 957 2 4
7 8 0.16 165 14.75 308 3 3

Cycle 181 GMT 21/ 4/2023 23:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 30 14.71 468 3 3
2 10 1000.08 2 14.72 1852 2 3
3 3 938.04 -1 15.08 0 2 3
4 3 955.92 -1 15.11 0 2 3
5 7 2004.48 37 14.43 3151 2 3
6 13 1408.96 19 14.48 2375 2 3
7 13 838.76 19 14.56 1596 2 4
8 13 391.96 19 14.66 935 2 4
9 13 18.72 19 14.77 330 3 3
10 8 0.04 165 14.74 298 3 3

Cycle 180 GMT 12/ 4/2023 2:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 30 14.71 470 3 3
2 7 2005.92 37 14.43 3154 2 3
3 13 1552.36 19 14.47 2559 2 3
4 13 929.60 19 14.54 1721 2 4
5 13 346.80 19 14.69 873 2 4
6 8 0.24 165 14.75 306 3 3

Cycle 179 GMT 2/ 4/2023 4:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 30 14.70 509 3 3
2 7 2002.84 37 14.43 3141 2 3
3 13 1402.16 19 14.49 2367 2 3
4 13 820.64 19 14.56 1562 2 4
5 13 384.32 19 14.67 928 2 4
6 8 0.08 165 14.75 305 3 3

Cycle 178 GMT 23/ 3/2023 6:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 30 14.71 486 3 3
2 7 2008.44 37 14.43 3144 2 3
3 13 1411.76 19 14.48 2381 2 3
4 13 835.08 19 14.56 1585 2 4
5 13 395.16 19 14.66 945 2 4
6 8 0.00 165 14.75 310 3 3

Cycle 177 GMT 13/ 3/2023 9:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 14.71 484 3 3
2 7 2005.56 37 14.44 3139 2 3
3 13 1565.84 19 14.47 2579 2 3
4 13 821.32 19 14.57 1564 2 4
5 13 394.24 19 14.67 950 2 4
6 8 0.00 165 14.75 309 3 3

Cycle 176 GMT 3/ 3/2023 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 30 14.71 505 3 3
2 7 2006.24 37 14.44 3146 2 3
3 13 1434.20 19 14.49 2406 2 3
4 13 872.28 19 14.55 1630 2 4
5 13 316.52 19 14.70 814 2 4
6 8 0.08 165 14.76 303 3 3

Cycle 175 GMT 21/ 2/2023 13:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 14.72 479 3 3
2 3 1014.04 1 14.81 1904 2 3
3 7 2004.28 37 14.44 3152 2 3
4 13 1422.40 19 14.49 2385 2 3
5 13 852.72 19 14.56 1598 2 4
6 13 415.00 19 14.66 976 2 5
7 8 0.04 165 14.75 309 3 3
8 14 0.04 30 14.73 307 3 3

Cycle 174 GMT 11/ 2/2023 15:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 30 14.71 497 3 3
2 7 2011.96 37 14.43 3165 2 3
3 13 1428.64 19 14.49 2412 2 3
4 13 863.64 19 14.56 1619 2 4
5 13 428.16 19 14.66 996 2 4
6 8 0.24 165 14.76 304 3 3

Cycle 173 GMT 1/ 2/2023 17:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 14.71 474 3 3
2 7 2010.96 37 14.43 3170 2 3
3 13 1547.60 19 14.47 2573 2 3
4 13 833.76 19 14.56 1597 2 4
5 13 399.80 19 14.67 956 2 5
6 13 21.36 19 14.78 345 3 3
7 8 0.16 165 14.75 311 3 3
8 14 0.16 30 14.73 312 3 4

Cycle 172 GMT 22/ 1/2023 19:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 30 14.72 475 3 3
2 7 2006.92 37 14.44 3146 2 3
3 13 1427.12 19 14.48 2400 2 3
4 13 842.68 19 14.56 1593 2 4
5 13 400.76 19 14.67 954 2 4
6 8 0.04 165 14.75 308 3 3

Cycle 171 GMT 12/ 1/2023 22:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 30 14.72 499 3 3
2 7 2004.60 37 14.43 3165 2 3
3 13 1410.60 19 14.49 2365 2 3
4 13 963.52 19 14.53 1757 2 4
5 13 369.60 19 14.68 905 2 4
6 8 0.16 165 14.75 305 3 3

Cycle 170 GMT 3/ 1/2023 0:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 30 14.73 474 3 3
2 7 2003.84 37 14.44 3146 2 3
3 13 1417.12 19 14.49 2386 2 3
4 13 849.32 19 14.56 1608 2 4
5 13 426.56 19 14.66 1001 2 5
6 8 0.24 165 14.76 306 3 3

Cycle 169 GMT 24/12/2022 2:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.72 462 3 3
2 3 1016.24 1 14.83 1911 2 3
3 7 2002.08 37 14.44 3166 2 3
4 13 1545.32 19 14.47 2570 2 3
5 13 932.52 19 14.54 1732 2 4
6 13 363.88 19 14.69 898 2 4
7 8 -0.08 165 14.76 306 3 3
8 14 -0.08 30 14.74 303 3 3

Cycle 168 GMT 14/12/2022 4:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 14.72 467 3 3
2 7 2002.72 37 14.44 3157 2 3
3 13 1416.32 19 14.49 2383 2 3
4 13 836.48 19 14.57 1578 2 4
5 13 402.76 19 14.67 943 2 4
6 13 50.28 19 14.78 381 3 3
7 8 -0.04 165 14.75 297 3 3

Cycle 167 GMT 4/12/2022 7:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.96 30 14.72 500 3 3
2 7 2007.36 37 14.44 3152 2 3
3 13 1318.28 19 14.51 2245 2 3
4 13 891.92 19 14.55 1670 2 4
5 13 330.00 19 14.70 849 3 4
6 13 40.12 19 14.78 369 3 3
7 8 0.08 165 14.75 304 3 3

Cycle 166 GMT 24/11/2022 9:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 30 14.72 480 3 3
2 7 2006.60 37 14.45 3156 2 3
3 13 1441.32 19 14.49 2412 2 3
4 13 868.68 19 14.56 1636 2 4
5 13 435.52 19 14.66 1008 2 4
6 13 55.88 19 14.77 400 3 3
7 8 -0.08 165 14.75 309 3 3
8 14 -0.08 30 14.73 308 3 3

Cycle 165 GMT 14/11/2022 11:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 30 14.73 471 3 3
2 7 2004.72 37 14.43 3169 2 3
3 13 1415.36 19 14.49 2398 2 3
4 13 837.48 19 14.57 1603 2 4
5 13 394.72 19 14.67 961 2 4
6 13 50.60 19 14.77 408 3 3
7 8 -0.08 165 14.75 317 3 7
8 14 -0.08 30 14.73 312 3 3

Cycle 164 GMT 4/11/2022 13:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 30 14.73 464 3 3
2 7 2008.68 37 14.44 3178 2 3
3 13 1439.00 19 14.49 2426 2 3
4 13 870.36 19 14.56 1634 2 4
5 13 440.32 19 14.66 1014 2 4
6 13 43.44 19 14.78 392 3 3
7 8 -0.04 165 14.76 311 3 3
8 14 -0.04 30 14.74 306 3 3

Cycle 163 GMT 25/10/2022 15:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 30 14.73 464 3 3
2 7 2011.84 37 14.44 3139 2 3
3 13 1412.28 19 14.50 2380 2 3
4 13 841.80 19 14.58 1577 2 4
5 13 411.24 19 14.68 957 2 4
6 13 46.44 19 14.78 377 3 3
7 8 0.08 165 14.76 302 3 5

Cycle 162 GMT 15/10/2022 17:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 30 14.73 481 3 3
2 7 2012.36 37 14.44 3165 2 3
3 13 1313.56 19 14.51 2241 2 3
4 13 894.80 19 14.55 1667 2 4
5 13 318.08 19 14.71 825 2 4
6 13 40.08 19 14.79 377 3 3
7 8 0.08 165 14.76 303 3 3

Cycle 161 GMT 5/10/2022 20: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 30 14.74 460 3 3
2 7 2004.16 38 14.44 3157 2 3
3 13 1415.48 19 14.50 2386 2 3
4 13 848.92 19 14.57 1611 2 4
5 13 411.00 19 14.68 966 2 4
6 13 46.20 19 14.79 385 3 3
7 8 0.08 165 14.76 306 3 3

Cycle 160 GMT 25/ 9/2022 22:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 30 14.75 463 3 3
2 7 2011.60 37 14.44 3151 2 3
3 13 1414.44 19 14.50 2383 2 3
4 13 834.04 19 14.58 1591 2 4
5 13 277.88 19 14.73 755 3 4
6 13 40.40 19 14.80 376 3 3
7 8 0.16 165 14.77 301 3 3

Cycle 159 GMT 16/ 9/2022 0:30:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 30 14.73 452 3 3
2 7 2004.28 37 14.44 3134 2 3
3 13 1417.16 19 14.50 2366 2 3
4 13 834.04 19 14.59 1575 2 4
5 13 292.72 19 14.73 774 3 4
6 13 29.84 19 14.80 352 3 3
7 8 0.16 165 14.77 300 3 3

Cycle 158 GMT 6/ 9/2022 2:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 14.75 451 3 3
2 7 2005.24 37 14.45 3161 2 3
3 13 1419.20 19 14.50 2383 2 3
4 13 836.24 19 14.59 1582 2 4
5 13 405.80 19 14.69 960 2 4
6 13 46.44 19 14.79 375 3 3
7 13 13.84 19 14.80 316 3 3
8 8 0.00 165 14.76 296 3 3

Cycle 157 GMT 27/ 8/2022 4:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 29 14.73 467 3 3
2 7 2003.44 37 14.44 3141 2 3
3 13 1422.08 19 14.50 2389 2 3
4 13 842.52 19 14.59 1579 2 4
5 13 292.24 19 14.73 775 2 4
6 13 25.60 19 14.80 337 3 3
7 8 0.20 165 14.78 296 3 3

Cycle 156 GMT 17/ 8/2022 6:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 29 14.75 452 3 3
2 7 2007.44 37 14.45 3154 2 3
3 13 1426.36 19 14.51 2389 2 3
4 13 856.84 19 14.58 1607 2 4
5 13 424.84 19 14.69 983 2 4
6 13 27.80 19 14.80 341 3 3
7 13 10.48 19 14.80 315 3 3
8 8 0.04 165 14.77 298 3 3

Cycle 155 GMT 7/ 8/2022 9: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 29 14.75 463 3 3
2 7 2008.16 37 14.45 3155 2 3
3 13 1428.68 19 14.51 2400 2 3
4 13 860.28 19 14.58 1622 2 4
5 13 432.76 19 14.68 1004 2 5
6 13 28.80 19 14.80 350 3 3
7 8 0.12 165 14.78 300 3 3

Cycle 154 GMT 28/ 7/2022 11:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 29 14.75 454 3 3
2 3 1014.64 1 14.84 1930 2 3
3 7 2011.44 37 14.44 3175 2 3
4 13 1417.40 19 14.50 2390 2 3
5 13 847.20 19 14.58 1598 2 4
6 13 291.56 19 14.73 784 2 4
7 13 32.32 19 14.81 351 3 3
8 8 0.16 165 14.78 300 3 3

Cycle 153 GMT 18/ 7/2022 13:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 29 14.74 485 3 3
2 7 2008.80 37 14.44 3155 2 3
3 13 1430.20 19 14.50 2405 2 3
4 13 857.48 19 14.58 1621 2 4
5 13 298.92 19 14.73 792 2 4
6 13 33.56 19 14.81 357 3 3
7 8 0.16 165 14.78 300 3 3

Cycle 152 GMT 8/ 7/2022 15:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 29 14.74 497 3 3
2 7 2003.36 37 14.45 3146 2 3
3 13 1413.68 19 14.51 2395 2 3
4 13 830.56 19 14.59 1585 2 4
5 13 390.60 19 14.70 956 2 5
6 13 21.28 19 14.81 338 3 3
7 8 0.12 165 14.78 306 3 3

Cycle 151 GMT 28/ 6/2022 17:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 29 14.74 475 3 3
2 7 2011.36 37 14.44 3165 2 3
3 13 1293.68 19 14.53 2230 2 3
4 13 858.36 19 14.58 1626 2 4
5 13 276.52 19 14.74 769 3 4
6 13 24.56 19 14.81 344 3 3
7 8 0.04 165 14.78 310 3 3

Cycle 150 GMT 18/ 6/2022 20: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 29 14.74 464 3 3
2 7 2004.96 38 14.45 3153 2 3
3 13 1425.96 19 14.51 2404 2 3
4 13 852.28 19 14.59 1615 2 4
5 13 284.36 19 14.74 781 2 4
6 13 24.76 19 14.81 347 3 3
7 8 0.04 165 14.78 310 3 3

Cycle 149 GMT 8/ 6/2022 22: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 29 14.75 492 3 3
2 7 2002.88 37 14.45 3147 2 3
3 13 1538.76 19 14.49 2562 2 3
4 13 793.96 19 14.61 1543 2 4
5 13 364.00 19 14.71 909 2 4
6 13 14.00 19 14.81 330 2 3
7 8 0.20 165 14.78 305 3 3

Cycle 148 GMT 30/ 5/2022 0:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 29 14.75 491 3 3
2 7 2011.24 38 14.44 3159 2 3
3 13 1311.08 19 14.53 2241 2 3
4 13 882.04 19 14.58 1657 2 4
5 13 298.08 19 14.73 801 2 4
6 8 0.08 165 14.79 308 3 3

Cycle 147 GMT 20/ 5/2022 2:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 29 14.75 493 3 3
2 7 2007.92 37 14.46 3175 2 3
3 13 1422.76 19 14.51 2407 2 3
4 13 851.16 19 14.59 1621 2 4
5 13 311.20 19 14.74 820 2 4
6 8 0.04 165 14.79 310 3 3

Cycle 146 GMT 10/ 5/2022 4:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 30 14.75 477 3 3
2 7 2003.68 37 14.46 3147 2 3
3 13 1281.84 19 14.55 2203 2 3
4 13 853.40 19 14.60 1612 2 4
5 13 279.28 19 14.75 769 2 4
6 8 0.12 165 14.79 310 3 3

Cycle 145 GMT 30/ 4/2022 7: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 30 14.75 501 3 3
2 7 2003.96 37 14.45 3151 2 3
3 13 1433.72 19 14.51 2407 2 3
4 13 859.16 19 14.60 1621 2 4
5 13 297.24 19 14.74 805 3 4
6 8 0.00 165 14.80 311 3 3

Cycle 144 GMT 20/ 4/2022 8:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 14.75 473 3 3
2 7 2006.44 38 14.45 3159 2 3
3 13 1547.84 19 14.49 2558 2 3
4 13 808.60 19 14.61 1550 2 4
5 13 376.96 19 14.72 914 2 4
6 8 0.04 165 14.80 313 3 3

Cycle 143 GMT 10/ 4/2022 11:20: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 29 14.76 501 3 3
2 3 1020.44 1 14.82 1914 2 3
3 7 2007.04 37 14.47 3141 2 3
4 13 1427.12 19 14.52 2383 2 3
5 13 856.04 19 14.60 1609 2 4
6 13 415.64 19 14.71 973 2 4
7 8 0.16 165 14.80 312 3 3

Cycle 142 GMT 31/ 3/2022 13:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 29 14.76 503 3 3
2 3 1024.60 1 14.83 1914 2 3
3 7 2010.68 37 14.46 3167 2 3
4 13 1403.08 19 14.53 2369 2 3
5 13 826.52 19 14.61 1569 2 4
6 13 379.20 19 14.73 913 2 4
7 8 0.08 165 14.80 311 3 3

Cycle 141 GMT 21/ 3/2022 16: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 29 14.95 479 3 3
2 7 2007.80 37 14.45 3173 2 3
3 13 1417.24 19 14.51 2403 2 3
4 13 824.64 19 14.61 1576 2 4
5 13 264.24 19 14.76 740 2 4
6 8 0.04 165 14.81 306 3 3

Cycle 140 GMT 11/ 3/2022 18:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 45 14.93 490 3 3
2 7 497.28 37 14.96 1036 3 3
3 8 0.12 165 15.00 295 3 3

Cycle 139 GMT 11/ 3/2022 12:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 45 14.93 472 3 3
2 7 497.64 37 14.96 1035 3 3
3 8 0.16 165 15.00 297 3 3

Cycle 138 GMT 11/ 3/2022 7:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 45 14.93 479 3 3
2 7 506.72 38 14.96 1052 3 3
3 8 0.12 165 15.00 290 3 3
4 14 0.12 30 14.98 292 3 3

Cycle 137 GMT 11/ 3/2022 2:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 45 14.93 480 3 3
2 7 505.32 37 14.96 1047 3 3
3 8 0.16 165 15.00 290 3 3

Cycle 136 GMT 10/ 3/2022 20:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 45 14.94 486 3 3
2 7 506.12 37 14.96 1040 3 3
3 8 0.20 165 15.00 289 3 3
4 14 0.20 30 14.98 292 3 3

Cycle 135 GMT 10/ 3/2022 15:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 45 14.94 476 3 3
2 7 504.16 37 14.96 1038 3 3
3 8 0.12 165 15.00 288 3 4

Cycle 134 GMT 10/ 3/2022 10: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 45 14.93 484 3 3
2 7 503.80 37 14.96 1040 3 3
3 8 0.16 165 15.00 288 3 3
4 14 0.16 30 14.98 289 3 3

Cycle 133 GMT 10/ 3/2022 4:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 45 14.93 491 3 3
2 7 499.24 38 14.96 1038 3 3
3 8 0.04 165 15.00 293 3 3

Cycle 132 GMT 9/ 3/2022 23:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 45 14.94 470 3 3
2 7 504.96 37 14.96 1054 3 3
3 8 -0.04 165 15.00 298 3 3

Cycle 131 GMT 9/ 3/2022 17:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 45 14.92 497 3 3
2 7 500.96 37 14.96 1036 3 3
3 8 0.12 165 15.00 292 3 3

Cycle 130 GMT 9/ 3/2022 12:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 45 14.93 462 3 3
2 7 499.52 37 14.96 1034 3 3
3 8 0.16 165 15.00 296 3 3
4 14 0.16 30 14.97 296 3 3

Cycle 129 GMT 9/ 3/2022 7:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 45 14.94 461 3 3
2 7 509.24 37 14.96 1055 3 3
3 8 0.08 165 15.00 295 3 3

Cycle 128 GMT 9/ 3/2022 1:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 45 14.94 491 3 3
2 7 501.96 37 14.96 1038 3 3
3 8 0.00 165 15.00 292 3 3

Cycle 127 GMT 8/ 3/2022 20:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 45 14.93 486 3 3
2 7 490.28 37 14.96 1015 3 3
3 8 0.00 165 15.00 290 3 3

Cycle 126 GMT 8/ 3/2022 15:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 45 14.93 469 3 3
2 7 499.88 37 14.96 1033 3 3
3 8 0.12 165 15.00 289 3 3

Cycle 125 GMT 8/ 3/2022 10: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 45 14.93 458 3 3
2 7 508.60 37 14.95 1050 3 3
3 8 0.04 165 14.99 291 3 3

Cycle 124 GMT 8/ 3/2022 4:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 45 14.92 466 3 3
2 7 503.28 37 14.95 1039 3 3
3 8 0.12 165 15.00 290 3 3

Cycle 123 GMT 7/ 3/2022 23:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.84 45 14.90 498 3 3
2 7 495.84 38 14.95 1031 3 3
3 8 0.16 165 14.99 288 3 3
4 14 0.16 30 14.97 289 3 3

Cycle 122 GMT 7/ 3/2022 17:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 45 14.90 501 3 3
2 7 515.44 37 14.92 1070 3 3
3 13 34.72 19 15.00 356 3 3
4 8 0.12 165 14.97 297 3 3
5 14 0.12 30 14.94 295 3 3

Cycle 121 GMT 7/ 3/2022 12:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 24 14.77 487 3 3
2 10 1020.68 5 14.74 1888 2 3
3 3 1035.16 1 14.81 1961 2 3
4 7 994.56 37 14.84 1802 2 4
5 13 239.32 19 14.98 712 2 4
6 8 0.00 165 14.97 312 3 3
7 14 0.00 30 14.95 306 3 3

Cycle 120 GMT 4/ 3/2022 17:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 14.94 468 3 3
2 7 2004.36 38 14.46 3159 2 3
3 13 1408.56 19 14.52 2386 2 3
4 13 824.04 19 14.61 1587 2 4
5 13 275.60 19 14.76 772 2 4
6 8 0.08 165 14.81 312 3 3
7 14 0.08 30 14.79 312 3 3

Cycle 119 GMT 22/ 2/2022 19:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 45 14.94 473 3 3
2 7 506.96 38 14.96 1051 3 3
3 13 24.28 19 15.03 330 3 3
4 8 0.12 165 15.00 289 3 3
5 14 0.12 30 14.97 290 3 3

Cycle 118 GMT 22/ 2/2022 14: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 45 14.92 505 3 3
2 7 503.00 37 14.96 1062 3 3
3 8 0.08 165 15.00 287 3 3
4 14 0.08 30 14.98 289 3 3

Cycle 117 GMT 22/ 2/2022 8:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 45 14.94 473 3 3
2 7 506.20 37 14.96 1060 3 3
3 13 31.28 19 15.03 352 3 3
4 8 0.00 165 14.99 302 3 3
5 14 0.00 30 14.97 302 3 4

Cycle 116 GMT 22/ 2/2022 3: 5: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 45 14.93 479 3 3
2 7 496.68 38 14.96 1050 3 3
3 8 0.12 165 15.00 291 3 3
4 14 0.12 30 14.98 294 3 3

Cycle 115 GMT 21/ 2/2022 21:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.00 45 14.93 484 3 3
2 7 503.08 37 14.96 1050 3 3
3 8 0.16 165 15.00 302 3 3

Cycle 114 GMT 21/ 2/2022 16:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 45 14.93 494 3 3
2 7 493.60 37 14.96 1032 3 3
3 8 0.08 165 15.00 290 3 3
4 14 0.08 30 14.98 290 3 5

Cycle 113 GMT 21/ 2/2022 10:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 45 14.93 482 3 3
2 7 495.16 37 14.95 1044 3 3
3 8 0.12 165 15.00 295 3 3

Cycle 112 GMT 21/ 2/2022 5:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 45 14.93 483 3 3
2 7 498.64 37 14.96 1051 3 3
3 8 -0.08 165 15.00 306 3 3
4 14 -0.08 30 14.97 303 3 3

Cycle 111 GMT 21/ 2/2022 0: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 45 14.93 479 3 3
2 7 501.48 37 14.95 1055 3 3
3 8 0.12 165 15.00 301 3 4
4 14 0.12 30 14.97 300 3 3

Cycle 110 GMT 20/ 2/2022 18:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 45 14.92 486 3 3
2 7 492.76 37 14.96 1035 3 3
3 8 -0.04 165 15.00 298 3 3
4 14 -0.04 30 14.97 299 3 3

Cycle 109 GMT 20/ 2/2022 13: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 45 14.92 474 3 3
2 7 512.76 37 14.94 1072 3 3
3 13 27.72 19 15.02 345 3 3
4 8 0.04 165 14.99 298 3 3

Cycle 108 GMT 20/ 2/2022 7:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 45 14.92 497 3 3
2 7 497.52 37 14.95 1052 3 3
3 8 0.08 165 14.99 310 3 3

Cycle 107 GMT 20/ 2/2022 2:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 45 14.92 493 3 3
2 7 493.20 38 14.95 1041 3 3
3 8 0.12 165 14.99 304 3 3

Cycle 106 GMT 19/ 2/2022 21: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 45 14.91 464 3 3
2 7 496.76 37 14.95 1045 3 3
3 8 0.08 165 14.99 299 3 3

Cycle 105 GMT 19/ 2/2022 15:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 45 14.92 476 3 3
2 7 514.20 37 14.93 1086 3 3
3 8 0.08 165 14.98 305 3 3
4 14 0.08 30 14.96 305 3 3

Cycle 104 GMT 19/ 2/2022 10:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 44 14.88 495 3 3
2 10 505.00 3 14.93 1091 3 3
3 7 453.76 37 14.95 987 3 3
4 8 0.12 165 14.99 298 3 3
5 14 0.12 30 14.96 304 4 3

Cycle 103 GMT 19/ 2/2022 5: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 35 14.76 500 3 3
2 10 590.40 6 14.81 1205 3 3
3 10 624.96 3 14.82 1264 3 3
4 3 583.16 3 14.85 1217 3 3
5 7 484.32 37 14.89 1038 3 3
6 8 0.04 165 14.94 306 3 3

Cycle 102 GMT 18/ 2/2022 23:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 29 14.77 503 3 3
2 7 2012.60 37 14.47 3174 2 3
3 13 1418.92 19 14.54 2402 2 3
4 13 842.36 19 14.62 1608 2 4
5 13 389.28 19 14.73 956 2 4
6 8 0.96 165 14.81 319 3 3
7 14 0.96 30 14.79 319 3 3

Cycle 101 GMT 9/ 2/2022 1:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 29 14.77 480 3 3
2 7 2008.76 37 14.47 3161 2 3
3 13 1442.76 19 14.52 2443 2 3
4 13 849.44 19 14.62 1629 2 4
5 13 288.68 19 14.77 789 3 4
6 8 0.04 165 14.82 315 3 3
7 14 0.04 30 14.79 314 3 3

Cycle 100 GMT 30/ 1/2022 3:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 29 14.78 481 3 3
2 7 2011.44 38 14.47 3167 2 3
3 13 1395.44 19 14.54 2363 2 3
4 13 821.04 19 14.63 1575 2 4
5 13 381.24 19 14.73 945 2 4
6 8 -0.08 165 14.81 310 3 3

Cycle 99 GMT 20/ 1/2022 6: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 14.78 478 3 3
2 7 2009.28 37 14.48 3160 2 3
3 13 1302.04 19 14.56 2240 2 3
4 13 886.32 19 14.61 1662 2 4
5 13 319.80 19 14.76 830 2 4
6 8 0.04 165 14.82 309 3 3
7 14 0.04 30 14.79 310 3 3

Cycle 98 GMT 10/ 1/2022 8: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 29 14.77 490 3 3
2 7 2011.64 37 14.48 3164 2 3
3 13 1411.44 19 14.54 2388 2 3
4 13 828.40 19 14.63 1585 2 4
5 13 282.80 19 14.77 779 2 4
6 8 0.16 165 14.82 309 3 3

Cycle 97 GMT 31/12/2021 10:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 14.77 482 3 3
2 7 2006.60 37 14.47 3169 2 3
3 13 1433.28 19 14.53 2421 2 3
4 13 847.48 19 14.62 1614 2 4
5 13 409.48 19 14.73 979 2 4
6 13 43.76 19 14.83 390 3 3
7 8 0.04 165 14.81 316 3 3

Cycle 96 GMT 21/12/2021 12:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 29 14.79 472 3 3
2 3 1022.96 1 14.85 1934 2 3
3 7 2009.56 37 14.48 3151 2 3
4 13 1436.08 19 14.54 2421 2 3
5 13 855.08 19 14.62 1618 2 4
6 13 409.84 19 14.73 974 2 4
7 13 51.84 19 14.83 411 3 3
8 8 0.00 165 14.81 313 3 3
9 14 0.00 30 14.78 314 3 3

Cycle 95 GMT 11/12/2021 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 14.78 475 3 3
2 7 2003.12 37 14.49 3145 2 3
3 13 1431.80 19 14.55 2407 2 3
4 13 851.24 19 14.63 1616 2 4
5 13 293.84 19 14.77 805 3 4
6 13 31.36 19 14.85 361 3 3
7 8 -0.12 165 14.82 312 3 3
8 14 -0.12 30 14.80 310 3 3

Cycle 94 GMT 1/12/2021 16:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 29 14.79 488 3 3
2 7 2008.00 37 14.48 3155 2 3
3 13 1298.12 19 14.56 2228 2 3
4 13 762.76 19 14.65 1490 2 4
5 13 327.52 19 14.76 850 2 4
6 13 39.08 19 14.84 382 3 3
7 8 0.08 165 14.82 316 3 3
8 14 0.08 30 14.79 312 3 4

Cycle 93 GMT 21/11/2021 18:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 29 14.78 476 3 3
2 7 2011.72 37 14.48 3157 2 3
3 13 1296.84 19 14.56 2239 2 3
4 13 866.00 19 14.62 1633 2 4
5 13 282.00 19 14.78 783 2 4
6 13 58.04 19 14.84 417 3 3
7 8 0.16 165 14.82 313 3 3
8 14 0.16 30 14.79 312 3 3

Cycle 92 GMT 11/11/2021 20:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 14.80 472 3 3
2 7 2004.68 37 14.48 3162 2 3
3 13 1418.84 19 14.54 2379 2 3
4 13 814.96 19 14.64 1561 2 4
5 13 368.48 19 14.75 923 2 4
6 13 45.28 19 14.85 393 3 3
7 8 0.00 165 14.82 315 3 3

Cycle 91 GMT 1/11/2021 22:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 29 14.80 460 3 3
2 7 2002.92 37 14.47 3161 2 3
3 13 1421.32 19 14.54 2397 2 3
4 13 831.36 19 14.64 1590 2 4
5 13 277.04 19 14.79 764 2 4
6 13 37.24 19 14.85 370 3 3
7 8 0.04 165 14.83 306 3 3

Cycle 90 GMT 23/10/2021 1: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 14.79 474 3 3
2 7 2004.36 37 14.48 3163 2 3
3 13 1418.12 19 14.54 2408 2 3
4 13 845.36 19 14.64 1603 2 4
5 13 299.80 19 14.78 801 2 4
6 13 43.04 19 14.85 381 3 3
7 8 0.04 165 14.83 305 3 3

Cycle 89 GMT 13/10/2021 3: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 29 14.80 485 3 3
2 7 2003.52 37 14.48 3174 2 3
3 13 1549.80 19 14.52 2587 2 3
4 13 927.68 19 14.61 1737 2 4
5 13 331.52 19 14.77 866 2 4
6 13 43.80 19 14.85 402 3 3
7 8 0.24 165 14.83 315 3 4
8 14 0.24 30 14.80 312 3 4

Cycle 88 GMT 3/10/2021 5:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 29 14.80 468 3 3
2 7 2003.72 38 14.48 3165 2 3
3 13 1409.60 19 14.54 2390 2 3
4 13 827.12 19 14.64 1597 2 4
5 13 272.68 19 14.79 769 2 4
6 13 36.52 19 14.86 382 3 3
7 8 0.00 165 14.83 314 3 3

Cycle 87 GMT 23/ 9/2021 7:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 29 14.79 484 3 3
2 7 2004.16 37 14.48 3168 2 3
3 13 1412.68 19 14.55 2399 2 3
4 13 825.32 19 14.64 1596 2 4
5 13 380.68 19 14.76 946 2 4
6 13 42.48 19 14.85 388 3 3
7 8 0.08 165 14.83 316 3 3

Cycle 86 GMT 13/ 9/2021 9:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 29 14.80 477 3 3
2 7 2002.92 37 14.48 3165 2 3
3 13 1411.68 19 14.54 2401 2 3
4 13 822.20 19 14.64 1597 2 4
5 13 384.48 19 14.75 956 2 4
6 13 38.28 19 14.85 397 3 3
7 8 0.08 165 14.82 324 3 3

Cycle 85 GMT 3/ 9/2021 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 29 14.80 489 3 3
2 7 2005.60 37 14.49 3167 2 3
3 13 1417.84 19 14.55 2411 2 3
4 13 959.88 19 14.61 1781 2 4
5 13 362.08 19 14.76 919 2 4
6 13 28.84 19 14.86 381 3 3
7 8 0.08 165 14.83 322 3 7

Cycle 84 GMT 24/ 8/2021 13:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 14.80 479 3 3
2 7 2003.76 37 14.48 3155 2 3
3 13 1408.60 19 14.55 2383 2 3
4 13 818.88 19 14.65 1572 2 4
5 13 269.32 19 14.80 766 2 4
6 13 25.00 19 14.87 360 3 3
7 8 0.16 165 14.83 314 3 3

Cycle 83 GMT 14/ 8/2021 15:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 29 14.80 463 3 3
2 7 2007.36 38 14.48 3159 2 3
3 13 1420.64 19 14.54 2406 2 3
4 13 825.72 19 14.65 1592 2 4
5 13 268.68 19 14.80 756 2 4
6 13 29.36 19 14.86 366 3 3
7 8 0.08 165 14.83 315 3 3

Cycle 82 GMT 4/ 8/2021 17:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 14.80 456 3 3
2 7 2002.68 37 14.50 3154 2 3
3 13 1424.88 19 14.56 2405 2 3
4 13 856.96 19 14.64 1627 2 4
5 13 298.24 19 14.79 806 2 4
6 13 35.88 19 14.87 374 3 3
7 8 0.08 165 14.84 312 3 3

Cycle 81 GMT 25/ 7/2021 20: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 14.80 467 3 3
2 7 2007.28 37 14.49 3164 2 3
3 13 1411.88 19 14.55 2384 2 3
4 13 827.92 19 14.65 1594 2 4
5 13 273.12 19 14.80 764 2 4
6 13 28.68 19 14.87 359 3 3
7 8 0.04 165 14.84 308 3 3
8 14 0.04 30 14.82 306 3 5

Cycle 80 GMT 15/ 7/2021 22:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 29 14.80 473 3 3
2 7 2005.04 37 14.49 3166 2 3
3 13 1416.68 19 14.55 2409 2 3
4 13 823.04 19 14.65 1577 2 4
5 13 268.12 19 14.81 760 3 4
6 13 26.84 19 14.87 362 3 3
7 8 0.04 165 14.84 311 3 3

Cycle 79 GMT 6/ 7/2021 0:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 14.80 477 3 3
2 7 2002.64 37 14.50 3155 2 3
3 13 1414.60 19 14.56 2393 2 3
4 13 848.08 19 14.65 1621 2 4
5 13 407.84 19 14.76 976 2 4
6 13 22.40 19 14.87 352 3 3
7 8 0.12 165 14.84 310 3 3

Cycle 78 GMT 26/ 6/2021 2:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 14.80 475 3 3
2 7 2004.20 37 14.50 3152 2 3
3 13 1413.76 19 14.56 2402 2 3
4 13 948.56 19 14.62 1767 2 4
5 13 350.56 19 14.78 895 2 4
6 13 18.08 19 14.87 359 3 3
7 8 0.12 165 14.84 317 3 3

Cycle 77 GMT 16/ 6/2021 4:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 29 14.80 488 3 3
2 7 2008.32 38 14.49 3176 2 3
3 13 1405.56 19 14.56 2383 2 3
4 13 817.44 19 14.66 1573 2 4
5 13 245.80 19 14.82 722 2 4
6 13 19.40 19 14.87 356 3 3
7 8 0.04 165 14.84 319 3 3

Cycle 76 GMT 6/ 6/2021 7: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 29 14.81 479 3 3
2 7 2007.04 37 14.51 3152 2 3
3 13 1416.96 19 14.57 2401 2 3
4 13 835.72 19 14.65 1603 2 4
5 13 389.84 19 14.76 959 2 5
6 13 22.68 19 14.87 372 2 3
7 8 0.00 165 14.84 323 2 3

Cycle 75 GMT 27/ 5/2021 9:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 14.81 484 3 3
2 7 2003.64 37 14.51 3161 2 3
3 13 1417.60 19 14.57 2395 2 3
4 13 826.84 19 14.66 1585 2 4
5 13 392.44 19 14.77 954 2 4
6 8 0.08 165 14.85 318 3 3

Cycle 74 GMT 17/ 5/2021 11:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 29 14.82 478 3 3
2 7 2007.08 37 14.50 3163 2 3
3 13 1432.68 19 14.56 2422 2 3
4 13 861.16 19 14.65 1628 2 4
5 13 300.28 19 14.80 817 2 4
6 8 0.08 165 14.85 319 3 3

Cycle 73 GMT 7/ 5/2021 13:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 14.82 488 3 3
2 7 2004.36 37 14.50 3156 2 3
3 13 1401.12 19 14.57 2376 2 3
4 13 809.92 19 14.67 1570 2 4
5 13 254.96 19 14.82 743 2 4
6 8 0.16 165 14.86 317 3 3

Cycle 72 GMT 27/ 4/2021 15:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 29 14.81 489 3 3
2 7 2008.04 37 14.51 3168 2 3
3 13 1279.00 19 14.59 2227 2 4
4 13 845.00 19 14.66 1608 2 4
5 13 279.12 19 14.81 788 2 4
6 8 0.08 165 14.86 318 3 3

Cycle 71 GMT 17/ 4/2021 17:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 29 14.83 475 3 3
2 3 1012.56 1 14.91 1941 2 3
3 7 2004.76 37 14.52 3147 2 3
4 13 1296.80 19 14.60 2242 2 4
5 13 873.40 19 14.65 1656 2 4
6 13 409.92 19 14.76 991 2 5
7 8 0.00 165 14.85 322 3 3

Cycle 70 GMT 7/ 4/2021 20: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 29 14.83 480 3 3
2 7 2009.92 37 14.51 3182 2 3
3 13 1403.24 19 14.58 2392 2 3
4 13 817.80 19 14.67 1573 2 4
5 13 266.56 19 14.82 754 2 4
6 8 0.08 165 14.87 310 3 3

Cycle 69 GMT 28/ 3/2021 22:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 14.83 483 3 3
2 7 2003.88 37 14.52 3164 2 3
3 13 1411.76 19 14.58 2397 2 3
4 13 822.16 19 14.68 1583 2 4
5 13 267.76 19 14.83 755 2 4
6 8 0.20 165 14.87 320 3 3

Cycle 68 GMT 19/ 3/2021 0:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 28 14.83 483 3 3
2 7 2004.72 37 14.52 3174 2 3
3 13 1410.76 19 14.58 2391 2 3
4 13 819.32 19 14.68 1582 2 4
5 13 250.84 19 14.83 734 3 4
6 8 0.00 165 14.87 318 3 3

Cycle 67 GMT 9/ 3/2021 2:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 28 14.83 488 3 3
2 7 2007.88 37 14.52 3180 2 3
3 13 1306.68 19 14.60 2249 2 3
4 13 854.28 19 14.67 1630 2 4
5 13 272.48 19 14.82 775 2 4
6 8 -0.04 165 14.87 316 3 3

Cycle 66 GMT 27/ 2/2021 4:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 28 14.84 479 3 3
2 7 2003.60 37 14.51 3183 2 3
3 13 1310.72 19 14.60 2274 2 3
4 13 770.92 19 14.69 1527 2 4
5 13 331.56 19 14.80 875 2 4
6 8 0.16 165 14.86 325 2 3

Cycle 65 GMT 17/ 2/2021 6:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 28 14.83 493 3 3
2 7 2011.56 37 14.52 3188 2 3
3 13 1409.44 19 14.59 2397 2 3
4 13 819.40 19 14.68 1584 2 4
5 13 258.12 19 14.84 745 2 4
6 8 0.00 165 14.88 314 3 3

Cycle 64 GMT 7/ 2/2021 8:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 28 14.85 470 3 3
2 7 2003.72 37 14.52 3180 2 3
3 13 1419.08 19 14.59 2421 2 3
4 13 823.32 19 14.68 1593 2 4
5 13 374.64 19 14.80 942 2 5
6 13 19.20 19 14.90 364 3 3
7 8 -0.12 165 14.86 321 3 3

Cycle 63 GMT 28/ 1/2021 10:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 28 14.85 471 3 3
2 7 2003.68 37 14.53 3169 2 3
3 13 1280.84 19 14.62 2230 2 4
4 13 833.28 19 14.68 1606 2 4
5 13 257.60 19 14.84 754 2 4
6 8 0.16 165 14.88 312 3 3

Cycle 62 GMT 18/ 1/2021 12:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 28 14.85 474 3 3
2 7 2004.20 37 14.53 3160 2 3
3 13 1408.68 19 14.60 2391 2 3
4 13 811.20 19 14.70 1574 2 4
5 13 259.96 19 14.85 756 2 4
6 8 0.08 165 14.89 317 3 3

Cycle 61 GMT 8/ 1/2021 14:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 28 14.86 499 3 3
2 7 2004.12 37 14.53 3152 2 3
3 13 1393.24 19 14.61 2363 2 3
4 13 784.36 19 14.71 1522 2 4
5 13 236.16 19 14.86 704 2 4
6 8 0.08 165 14.89 311 3 3

Cycle 60 GMT 29/12/2020 16:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 28 14.85 484 3 3
2 7 2002.56 37 14.54 3165 2 3
3 13 1294.76 19 14.62 2246 2 4
4 13 864.60 19 14.68 1647 2 4
5 13 262.76 19 14.85 763 2 4
6 8 0.12 165 14.89 317 3 3
7 14 0.12 30 14.87 322 3 3

Cycle 59 GMT 19/12/2020 18:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 14.87 479 3 3
2 7 2004.68 37 14.54 3163 2 3
3 13 1287.52 19 14.63 2224 2 4
4 13 847.12 19 14.70 1616 2 4
5 13 264.84 19 14.86 758 2 4
6 13 52.00 19 14.91 415 3 3
7 8 0.04 165 14.89 322 3 3

Cycle 58 GMT 9/12/2020 20:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 14.86 493 3 3
2 7 2012.88 37 14.54 3169 2 3
3 13 1414.32 19 14.61 2405 2 3
4 13 845.08 19 14.70 1626 2 4
5 13 278.28 19 14.86 782 2 4
6 8 -0.04 165 14.90 320 3 3

Cycle 57 GMT 29/11/2020 22:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.87 474 3 3
2 7 2004.08 37 14.55 3166 2 3
3 13 1411.92 19 14.62 2385 2 3
4 13 961.72 19 14.68 1781 2 4
5 13 356.68 19 14.83 907 2 4
6 13 41.44 19 14.92 396 3 3
7 8 0.00 165 14.89 327 3 3

Cycle 56 GMT 20/11/2020 1:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 28 14.86 489 3 3
2 7 2007.08 37 14.55 3167 2 3
3 13 1397.52 19 14.62 2374 2 3
4 13 803.96 19 14.72 1563 2 4
5 13 238.88 19 14.88 715 2 4
6 13 45.80 19 14.93 405 3 3
7 8 0.12 165 14.90 318 3 3

Cycle 55 GMT 10/11/2020 3:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 28 14.87 479 3 3
2 7 2005.80 37 14.55 3165 2 3
3 13 1301.36 19 14.64 2243 2 4
4 13 864.12 19 14.71 1642 2 4
5 13 290.00 19 14.86 802 2 4
6 13 31.00 19 14.93 382 3 3
7 8 0.08 165 14.90 324 3 3

Cycle 54 GMT 31/10/2020 5:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 14.87 473 3 3
2 3 1016.16 1 14.93 1935 2 3
3 7 2007.48 37 14.55 3183 2 3
4 13 1280.60 19 14.64 2237 2 4
5 13 735.96 19 14.75 1476 2 4
6 13 308.64 19 14.86 838 2 4
7 13 36.84 19 14.93 396 3 3
8 8 0.04 165 14.91 323 3 3

Cycle 53 GMT 21/10/2020 7:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 14.88 479 3 3
2 7 2008.52 37 14.56 3179 2 3
3 13 1413.56 19 14.62 2407 2 3
4 13 845.08 19 14.73 1603 2 4
5 13 391.84 19 14.84 949 2 5
6 13 51.96 19 14.93 405 3 3
7 8 0.08 165 14.91 315 3 6

Cycle 52 GMT 11/10/2020 9:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 14.88 476 3 3
2 7 2007.48 37 14.55 3168 2 3
3 13 1281.88 19 14.66 2221 2 4
4 13 733.84 19 14.76 1458 2 4
5 13 312.40 19 14.87 830 2 4
6 13 40.76 19 14.94 392 3 3
7 8 -0.04 165 14.92 321 3 5

Cycle 51 GMT 1/10/2020 11:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 14.89 477 3 3
2 7 2007.20 37 14.55 3176 2 3
3 13 1421.04 19 14.62 2418 2 3
4 13 836.08 19 14.73 1607 2 4
5 13 383.80 19 14.85 956 2 5
6 13 42.72 19 14.94 389 3 3
7 8 0.04 165 14.92 316 3 3

Cycle 50 GMT 21/ 9/2020 13:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 14.89 479 3 3
2 7 2008.36 37 14.55 3184 2 3
3 13 1288.28 19 14.65 2238 2 4
4 13 857.56 19 14.73 1632 2 4
5 13 270.96 19 14.89 776 2 4
6 13 50.44 19 14.95 410 3 3
7 8 0.12 165 14.92 317 3 3

Cycle 49 GMT 11/ 9/2020 15:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.90 475 3 3
2 7 2002.72 37 14.57 3183 2 3
3 13 1401.72 19 14.64 2386 2 3
4 13 826.04 19 14.75 1591 2 4
5 13 376.68 19 14.86 946 2 5
6 13 28.52 19 14.96 380 3 3
7 8 0.04 165 14.93 323 3 4

Cycle 48 GMT 1/ 9/2020 17:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 28 14.90 507 3 3
2 7 2005.08 38 14.56 3180 2 3
3 13 1386.40 19 14.64 2379 2 3
4 13 801.20 19 14.75 1568 2 4
5 13 246.72 19 14.91 742 3 4
6 13 27.80 19 14.97 377 3 3
7 8 0.12 165 14.93 324 3 3

Cycle 47 GMT 22/ 8/2020 19:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 14.89 489 3 3
2 7 2002.16 37 14.56 3171 2 3
3 13 1273.68 19 14.67 2225 2 4
4 13 738.44 19 14.77 1474 2 4
5 13 302.36 19 14.89 823 2 4
6 13 25.52 19 14.96 375 3 3
7 8 0.00 165 14.93 328 3 3

Cycle 46 GMT 12/ 8/2020 21:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 14.90 490 3 3
2 7 2006.12 37 14.57 3171 2 3
3 13 1429.56 19 14.64 2429 2 3
4 13 829.20 19 14.75 1610 2 5
5 13 387.92 19 14.86 977 2 5
6 13 20.88 19 14.96 381 3 3
7 8 0.00 165 14.93 332 3 3

Cycle 45 GMT 2/ 8/2020 23:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 28 14.91 504 3 3
2 7 2007.72 37 14.57 3189 2 3
3 13 1418.16 19 14.64 2423 2 3
4 13 834.80 19 14.75 1622 2 4
5 13 388.96 19 14.86 975 2 5
6 13 22.20 19 14.97 376 3 3
7 8 0.04 165 14.94 330 3 3

Cycle 44 GMT 24/ 7/2020 1:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 28 14.91 495 3 3
2 7 2003.20 37 14.57 3183 2 3
3 13 1395.92 19 14.66 2373 2 3
4 13 703.84 19 14.79 1436 2 4
5 13 276.76 19 14.91 794 2 4
6 13 26.04 19 14.97 385 2 3
7 8 0.08 165 14.94 331 3 4

Cycle 43 GMT 14/ 7/2020 3:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 14.91 492 3 3
2 7 2005.80 37 14.57 3182 2 3
3 13 1399.72 19 14.65 2388 2 3
4 13 813.08 19 14.76 1587 2 4
5 13 242.64 19 14.92 741 2 4
6 13 18.84 19 14.98 377 2 3
7 8 0.04 165 14.95 330 3 3

Cycle 42 GMT 4/ 7/2020 5:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 14.92 484 3 3
2 7 2002.68 37 14.57 3175 2 3
3 13 1405.48 19 14.66 2407 2 3
4 13 807.68 19 14.77 1578 2 4
5 13 363.52 19 14.89 927 2 5
6 13 22.68 19 14.98 380 3 3
7 8 0.12 165 14.95 329 3 4

Cycle 41 GMT 24/ 6/2020 7:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 28 14.93 468 3 3
2 7 2005.56 38 14.59 3164 2 3
3 13 1400.72 19 14.66 2396 2 3
4 13 803.76 19 14.78 1574 2 4
5 13 232.00 19 14.94 709 2 4
6 13 20.68 19 14.99 362 3 3
7 8 0.00 165 14.96 323 3 5

Cycle 40 GMT 14/ 6/2020 9:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 28 14.93 469 3 3
2 7 2002.32 37 14.59 3168 2 3
3 13 1403.84 19 14.67 2392 2 4
4 13 824.88 19 14.78 1604 2 4
5 13 261.24 19 14.94 743 2 4
6 13 22.52 19 15.00 355 3 3
7 8 0.12 165 14.96 315 3 3

Cycle 39 GMT 4/ 6/2020 11:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 28 14.93 497 3 3
2 7 2004.36 30 14.64 3187 2 3
3 13 1579.88 19 14.65 2627 2 3
4 13 993.48 19 14.74 1823 2 4
5 13 537.52 19 14.84 1183 2 5
6 13 48.96 19 14.99 399 3 3
7 8 0.12 165 14.96 321 3 3

Cycle 38 GMT 25/ 5/2020 13:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 28 14.92 518 3 3
2 7 2006.52 31 14.64 3187 2 3
3 13 1460.48 19 14.67 2471 2 3
4 13 909.68 19 14.76 1711 2 4
5 13 475.48 19 14.87 1080 2 5
6 13 39.28 19 14.99 393 3 3
7 8 0.20 165 14.97 320 3 3

Cycle 37 GMT 15/ 5/2020 15:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 14.94 488 3 3
2 7 2006.36 30 14.64 3185 2 3
3 13 1464.16 19 14.68 2470 2 3
4 13 917.68 19 14.77 1725 2 4
5 13 494.60 19 14.87 1113 2 4
6 13 39.96 19 14.99 413 3 3
7 8 -0.08 165 14.96 336 3 3

Cycle 36 GMT 5/ 5/2020 17:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 28 14.94 491 3 3
2 7 2005.20 30 14.64 3177 2 3
3 13 1589.80 19 14.65 2647 2 3
4 13 1002.08 19 14.75 1848 2 4
5 13 433.44 19 14.89 1026 2 4
6 13 26.88 19 15.01 377 3 3
7 8 0.04 165 14.98 325 3 3

Cycle 35 GMT 25/ 4/2020 19:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.88 28 14.94 517 3 3
2 7 2003.56 30 14.65 3163 2 3
3 13 1571.00 19 14.66 2620 2 3
4 13 973.96 19 14.76 1809 2 4
5 13 417.24 19 14.90 996 2 4
6 13 24.92 19 15.01 369 3 3
7 8 0.12 165 14.98 327 3 3

Cycle 34 GMT 15/ 4/2020 21:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 28 14.95 519 3 3
2 7 2004.00 30 14.64 3169 2 3
3 13 1594.44 19 14.66 2648 2 3
4 13 989.72 19 14.76 1821 2 4
5 13 415.28 19 14.90 994 2 4
6 13 27.36 19 15.01 391 2 3
7 8 -0.08 165 14.98 334 3 4

Cycle 33 GMT 5/ 4/2020 22:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 28 14.95 511 3 3
2 7 2002.52 30 14.65 3177 2 3
3 13 1458.28 19 14.69 2486 2 3
4 13 911.24 19 14.78 1726 2 4
5 13 370.20 19 14.92 939 2 4
6 8 0.04 165 14.99 329 3 3

Cycle 32 GMT 27/ 3/2020 0:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 28 14.95 515 3 3
2 7 2004.16 31 14.65 3185 2 3
3 13 1566.52 19 14.67 2615 2 3
4 13 969.16 19 14.77 1802 2 4
5 13 524.84 19 14.88 1162 2 4
6 13 19.68 19 15.02 363 3 3
7 8 0.12 165 14.99 325 3 3

Cycle 31 GMT 17/ 3/2020 2:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 28 14.96 492 3 3
2 7 2006.96 30 14.66 3175 2 3
3 13 1591.56 19 14.68 2631 2 3
4 13 991.16 19 14.77 1812 2 4
5 13 432.20 19 14.91 1030 2 5
6 13 26.88 19 15.02 387 3 3
7 8 0.04 165 14.99 329 3 4

Cycle 30 GMT 7/ 3/2020 4:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 14.95 501 3 3
2 7 2003.64 30 14.66 3179 2 3
3 13 1576.28 19 14.68 2606 2 3
4 13 874.04 19 14.81 1656 2 4
5 13 456.40 19 14.90 1060 2 5
6 13 33.48 19 15.02 395 3 3
7 8 0.00 165 14.99 329 3 3

Cycle 29 GMT 26/ 2/2020 6:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 28 14.97 495 3 3
2 7 2005.16 30 14.66 3187 2 3
3 13 1583.80 19 14.67 2643 2 3
4 13 981.96 19 14.78 1811 2 4
5 13 535.00 19 14.88 1185 2 5
6 13 45.16 19 15.02 414 3 3
7 8 -0.04 165 14.99 329 3 3

Cycle 28 GMT 16/ 2/2020 8:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 28 14.97 493 3 3
2 7 2004.96 30 14.67 3185 2 3
3 13 1467.44 19 14.70 2479 2 3
4 13 1028.08 19 14.77 1875 2 4
5 13 444.56 19 14.91 1044 2 4
6 8 0.16 165 15.00 327 3 3

Cycle 27 GMT 6/ 2/2020 10: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 28 14.96 520 3 3
2 7 2008.44 30 14.66 3195 2 3
3 13 1578.72 19 14.68 2642 2 3
4 13 989.36 19 14.78 1843 2 4
5 13 412.56 19 14.93 995 2 4
6 13 58.64 19 15.02 438 3 3
7 8 0.16 165 15.00 328 3 3

Cycle 26 GMT 27/ 1/2020 11:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 27 14.97 488 3 3
2 7 2005.16 30 14.68 3189 2 3
3 13 1590.56 19 14.69 2647 2 3
4 13 991.96 19 14.79 1832 2 4
5 13 541.32 19 14.89 1202 2 5
6 13 56.16 19 15.03 437 3 3
7 8 0.08 165 15.00 333 3 3

Cycle 25 GMT 17/ 1/2020 13:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 27 14.98 492 3 3
2 7 2002.68 30 14.68 3189 2 3
3 13 1453.12 19 14.72 2467 2 3
4 13 904.64 19 14.81 1699 2 4
5 13 474.36 19 14.91 1090 2 4
6 13 37.12 19 15.04 398 3 3
7 8 0.16 165 15.01 328 3 4

Cycle 24 GMT 7/ 1/2020 15:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 27 14.97 499 3 3
2 7 2003.08 30 14.69 3187 2 3
3 13 1590.44 19 14.70 2649 2 3
4 13 1006.84 19 14.79 1849 2 4
5 13 439.08 19 14.93 1039 2 5
6 13 68.24 19 15.03 449 3 3
7 8 0.24 165 15.01 322 3 4

Cycle 23 GMT 28/12/2019 17:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 27 14.98 471 3 3
2 7 2003.16 30 14.68 3197 2 3
3 13 1568.84 19 14.70 2623 2 3
4 13 861.28 19 14.83 1652 2 4
5 13 436.84 19 14.93 1041 2 5
6 13 64.80 19 15.03 445 3 3
7 8 -0.20 165 15.01 323 3 5
8 14 -0.20 30 14.99 321 3 4

Cycle 22 GMT 18/12/2019 19:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 27 14.98 483 3 3
2 7 2003.88 30 14.68 3178 2 3
3 13 1453.64 19 14.73 2470 2 3
4 13 892.24 19 14.83 1688 2 5
5 13 441.40 19 14.93 1044 2 5
6 13 60.36 19 15.04 430 2 3
7 8 0.24 165 15.02 319 3 5
8 14 0.24 30 15.00 320 3 4

Cycle 21 GMT 8/12/2019 21: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 27 14.98 485 3 3
2 7 2003.80 30 14.69 3181 2 3
3 13 1577.44 19 14.71 2629 2 3
4 13 964.00 19 14.81 1798 2 4
5 13 506.36 19 14.91 1140 2 5
6 13 47.80 19 15.04 406 3 3
7 8 0.04 165 15.02 318 3 3

Cycle 20 GMT 28/11/2019 23: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 27 15.00 500 3 3
2 7 2004.80 30 14.69 3184 2 3
3 13 1457.72 19 14.74 2474 2 3
4 13 894.76 19 14.83 1694 2 4
5 13 457.44 19 14.93 1071 2 5
6 13 60.72 19 15.04 440 3 3
7 8 0.08 165 15.02 323 3 3

Cycle 19 GMT 19/11/2019 1: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 14.99 478 3 3
2 7 2002.24 30 14.69 3174 2 3
3 13 1584.08 19 14.72 2648 2 3
4 13 981.64 19 14.82 1815 2 5
5 13 395.68 19 14.96 979 2 5
6 13 47.28 19 15.05 408 3 3
7 8 0.24 165 15.03 325 3 4

Cycle 18 GMT 9/11/2019 3: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 27 14.99 486 3 3
2 7 2003.36 30 14.69 3195 2 3
3 13 1574.12 19 14.72 2639 2 3
4 13 973.28 19 14.82 1804 2 4
5 13 391.40 19 14.96 966 2 5
6 13 43.12 19 15.05 404 3 3
7 8 0.12 165 15.03 323 3 3

Cycle 17 GMT 30/10/2019 4:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 27 15.00 495 3 3
2 7 2002.36 30 14.70 3179 2 3
3 13 1450.08 19 14.75 2470 2 3
4 13 882.88 19 14.84 1689 2 4
5 13 441.16 19 14.94 1055 2 5
6 13 33.92 19 15.06 390 2 3
7 8 0.00 165 15.03 330 2 3

Cycle 16 GMT 20/10/2019 6:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 27 15.01 461 3 3
2 7 2001.84 30 14.70 3180 2 3
3 13 1554.00 19 14.74 2598 2 3
4 13 948.08 19 14.84 1755 2 5
5 13 508.36 19 14.93 1149 2 5
6 13 42.12 19 15.06 409 3 3
7 8 0.12 165 15.04 320 3 4

Cycle 15 GMT 10/10/2019 8:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 27 15.01 477 3 3
2 7 2002.08 31 14.71 3183 2 3
3 13 1564.08 19 14.74 2612 2 3
4 13 959.72 19 14.83 1798 2 4
5 13 390.68 19 14.97 959 2 4
6 13 46.84 19 15.07 401 3 3
7 8 0.20 165 15.04 309 3 4

Cycle 14 GMT 30/ 9/2019 10:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 15.02 473 3 3
2 7 2003.68 30 14.72 3184 2 3
3 13 1581.44 19 14.73 2646 2 3
4 13 977.64 19 14.83 1808 2 4
5 13 412.68 19 14.97 997 2 5
6 13 54.96 19 15.06 423 3 3
7 8 -0.04 165 15.04 321 3 3

Cycle 13 GMT 20/ 9/2019 11:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 27 15.02 501 3 3
2 7 2005.88 30 14.72 3171 2 3
3 13 1589.52 19 14.74 2633 2 3
4 13 974.48 19 14.84 1802 2 5
5 13 394.28 19 14.98 974 2 4
6 13 50.36 19 15.07 412 2 3
7 8 0.08 165 15.05 318 3 4

Cycle 12 GMT 10/ 9/2019 13:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 15.01 477 3 3
2 7 2004.72 31 14.72 3180 2 3
3 13 1572.08 19 14.75 2615 2 3
4 13 962.08 19 14.85 1782 2 4
5 13 503.12 19 14.94 1136 2 5
6 13 37.52 19 15.07 395 3 3
7 8 0.04 165 15.04 324 3 3

Cycle 11 GMT 31/ 8/2019 15:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 27 15.02 476 3 3
2 7 2003.84 29 14.74 3186 2 3
3 13 1596.04 18 14.75 2671 2 3
4 13 1017.68 18 14.84 1876 2 4
5 13 560.04 18 14.94 1221 2 5
6 13 53.76 18 15.07 418 3 3
7 13 13.40 18 15.08 347 3 3
8 8 0.04 165 15.04 315 3 3

Cycle 10 GMT 21/ 8/2019 17:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 27 15.01 494 3 3
2 7 2002.80 29 14.74 3189 2 3
3 13 1716.56 18 14.73 2831 2 3
4 13 1104.32 18 14.83 1997 2 4
5 13 513.88 18 14.95 1162 2 5
6 13 47.92 18 15.08 425 3 3
7 8 -0.04 165 15.05 330 3 3
8 14 -0.04 30 15.03 323 3 3

Cycle 9 GMT 11/ 8/2019 19:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 27 15.03 456 3 3
2 7 2002.12 29 14.75 3163 2 3
3 13 1559.88 18 14.77 2600 2 3
4 13 971.56 18 14.86 1792 2 4
5 13 526.68 18 14.95 1154 2 5
6 13 53.64 18 15.08 439 3 3
7 8 0.12 165 15.05 340 3 3

Cycle 8 GMT 1/ 8/2019 21:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 27 15.03 466 3 3
2 7 2004.80 27 14.78 3166 2 3
3 13 1576.48 18 14.78 2615 2 3
4 13 1010.88 18 14.86 1843 2 4
5 13 585.16 18 14.94 1232 2 5
6 13 72.40 18 15.08 440 3 3
7 13 20.72 18 15.09 338 3 3
8 8 -0.08 165 15.06 303 3 4

Cycle 7 GMT 22/ 7/2019 23: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.44 27 15.04 484 3 3
2 3 1024.56 1 15.05 1939 2 3
3 7 2002.56 27 14.78 3174 2 3
4 13 1602.24 18 14.78 2644 2 3
5 13 1021.28 18 14.86 1853 2 4
6 13 579.52 18 14.95 1230 2 4
7 13 65.96 18 15.08 432 3 3
8 8 0.08 165 15.06 308 3 3

Cycle 6 GMT 13/ 7/2019 0:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 26 15.03 461 3 3
2 3 1035.40 1 15.03 1976 2 3
3 7 2003.56 30 14.75 3187 2 3
4 13 1567.96 18 14.78 2619 2 3
5 13 985.68 18 14.86 1809 2 4
6 13 434.84 18 14.99 1012 2 4
7 13 64.48 18 15.09 426 3 3
8 8 0.04 165 15.07 304 3 3

Cycle 5 GMT 3/ 7/2019 2:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 23 15.04 458 3 3
2 10 1025.68 3 15.00 1884 3 3
3 7 2002.12 31 14.75 3154 2 3
4 13 1441.48 18 14.81 2430 2 3
5 13 882.48 18 14.89 1667 2 4
6 13 451.48 18 14.99 1043 2 4
7 13 61.68 18 15.08 420 3 3
8 8 0.00 165 15.07 307 3 4

Cycle 4 GMT 23/ 6/2019 4: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 27 15.04 461 3 3
2 3 970.00 -1 15.34 0 3 3
3 3 1049.28 1 15.05 1975 2 3
4 7 1524.28 38 14.83 2517 2 3
5 13 1114.16 18 14.88 1991 2 4
6 13 682.04 18 14.95 1380 2 4
7 13 109.32 18 15.09 492 3 3
8 13 19.88 18 15.10 340 3 3
9 8 0.08 165 15.07 304 3 3

Cycle 3 GMT 22/ 6/2019 4: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 27 15.04 465 3 3
2 3 963.40 -1 15.34 0 3 3
3 3 1040.60 1 15.06 1943 2 3
4 7 1524.80 38 14.84 2487 2 3
5 13 1132.64 18 14.89 1965 2 4
6 13 689.92 18 14.95 1358 2 5
7 13 123.00 18 15.09 501 3 3
8 8 0.08 165 15.08 302 3 3

Cycle 2 GMT 21/ 6/2019 3:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 24 15.07 475 3 3
2 10 1036.28 2 15.02 1882 2 3
3 7 1508.88 74 14.76 2447 2 3
4 13 240.00 18 15.06 678 2 4
5 13 17.68 18 15.11 318 3 3
6 8 0.04 165 15.08 288 3 3

Cycle 1 GMT 20/ 6/2019 4:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 23 15.22 429 3 3
2 10 1032.96 3 15.06 1863 3 3
3 7 1001.52 74 14.91 1749 2 5
4 8 0.16 165 15.11 292 3 3

Cycle 0 GMT 19/ 6/2019 18:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 146.08 22 15.36 480 3 3
2 7 160.24 74 15.33 486 3 3
3 8 0.16 240 15.29 248 3 8