SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 7010 WMO= 3901031


Cycle 88

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.04 35 14.23 500 6 6
2 2004.72 70 10.38 2706 6 12
3 1806.24 24 12.18 2616 6 24
4 1351.64 24 12.59 2134 6 42
5 882.44 25 13.04 1555 6 51
6 185.20 24 13.86 657 6 57
7 45.44 24 14.16 466 6 53
8 -0.20 300 13.67 479 6 78

Cycle 87 GMT 30/ 4/2013 16:52:30

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 35 14.29 461 6 6
2 2004.64 70 10.36 2730 6 13
3 1801.28 24 12.23 2620 6 23
4 1165.52 24 12.72 1924 6 45
5 729.64 24 13.20 1376 6 54
6 140.24 24 13.91 609 6 57
7 65.96 24 14.05 545 6 55
8 -0.32 25 14.17 470 6 48
9 -0.44 300 13.56 493 6 90

Cycle 84 GMT 31/ 3/2013 17:48:46

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.60 35 14.10 500 6 6
2 2002.20 70 10.43 2749 6 13
3 1781.08 24 12.27 2549 6 25
4 1356.68 25 12.64 2136 6 40
5 880.24 24 13.07 1582 6 52
6 180.56 24 13.85 678 6 58
7 42.56 24 14.17 449 6 53
8 5.88 24 14.25 386 6 50
9 -0.48 25 14.20 374 6 51
10 -0.40 287 13.63 470 6 144

Cycle 66 GMT 2/10/2012 23:14:55

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.88 34 14.36 480 6 6
2 2001.08 70 10.68 2706 6 8
3 1783.96 24 12.49 2628 6 29
4 1324.40 24 12.92 2138 6 47
5 677.84 24 13.52 1297 6 59
6 122.20 24 14.12 583 6 54
7 55.72 25 14.26 488 6 54
8 1.48 301 13.71 503 6 73

Cycle 58 GMT 15/ 7/2012 1:53:12

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 34 14.48 461 6 6
2 2001.00 70 12.12 2653 6 14
3 1560.52 25 13.00 2359 6 40
4 1110.56 25 13.31 1889 6 51
5 421.24 25 13.92 966 6 61
6 81.28 25 14.26 587 6 54
7 3.56 25 14.39 497 6 46
8 -0.36 25 14.30 478 6 47
9 -0.40 289 13.94 404 6 159

Cycle 57 GMT 5/ 7/2012 2:22:29

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.04 34 14.55 442 6 6
2 2001.28 70 12.19 2659 6 19
3 1540.88 25 13.09 2315 6 39
4 891.24 25 13.54 1538 6 56
5 433.08 25 13.93 984 6 62
6 81.92 25 14.27 605 6 56
7 -0.48 25 14.43 468 6 61
8 -0.44 300 14.01 369 6 103

Cycle 55 GMT 15/ 6/2012 3:28:15

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.24 34 14.48 480 6 6
2 2004.12 70 12.25 2653 6 18
3 1558.32 25 13.08 2390 6 40
4 893.08 25 13.57 1574 6 57
5 437.04 25 13.92 1030 6 61
6 54.60 25 14.36 555 6 52
7 27.56 25 14.29 543 6 48
8 -0.28 25 14.39 439 6 47
9 -0.32 286 13.93 430 6 142

Cycle 52 GMT 3/ 6/2012 7:57: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.16 30 14.55 442 6 6
2 1096.40 2 14.04 1980 6 20
3 1220.72 70 12.89 1918 20 32
4 1030.88 25 13.47 1770 6 43
5 364.40 25 13.94 1062 6 55
6 68.16 25 14.29 666 6 50
7 34.28 25 14.33 520 6 48
8 -0.48 25 14.40 466 6 46
9 -0.40 294 13.85 485 6 152

Cycle 9 GMT 14/11/2011 13:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.72 30 14.55 480 6 7
2 1107.40 70 13.24 1784 6 47
3 905.92 25 13.55 1636 6 52
4 204.36 25 14.10 903 6 62
5 36.96 25 14.41 563 6 59
6 -0.28 25 14.45 492 6 56
7 -0.28 262 14.10 343 6 149

Cycle 8 GMT 4/11/2011 19:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 30 14.61 461 6 7
2 1095.48 70 13.23 1780 7 47
3 899.36 25 13.58 1568 6 53
4 220.12 25 14.26 680 6 65
5 38.44 25 14.56 411 6 59
6 -0.20 25 14.57 370 6 64
7 -0.24 260 14.08 364 6 135

Cycle 4 GMT 26/ 9/2011 21:38:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 30 14.29 730 6 6
2 1123.32 70 12.95 2110 10 33
3 741.04 25 13.41 1686 6 46
4 288.84 25 14.00 961 6 55
5 49.84 25 14.38 584 6 50
6 -0.44 295 13.94 409 6 139

Cycle 3 GMT 25/ 9/2011 23:34: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.00 30 14.55 442 6 6
2 1076.28 70 13.14 1734 6 38
3 866.88 25 13.49 1495 6 46
4 174.32 25 14.29 601 6 59
5 28.52 25 14.54 376 6 53
6 -0.36 25 14.55 338 6 54
7 -0.28 276 13.67 603 6 148

Cycle 2 GMT 25/ 9/2011 2: 9: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 30 14.55 442 6 6
2 1108.72 70 13.06 1773 6 39
3 913.00 25 13.41 1566 6 46
4 226.00 25 14.16 680 6 60
5 42.52 25 14.48 397 6 53
6 -0.32 25 14.54 330 6 55
7 -0.40 262 13.99 328 6 145

Cycle 0 GMT 23/ 9/2011 18:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 71.76 70 14.15 385 140 8
2 82.32 25 14.48 401 6 9
3 46.08 25 14.57 353 6 9
4 0.28 300 14.34 288 6 239