SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.28 | 49 | 10.41 | 500 | 6 | 6 |
2 | 1012.20 | 101 | 7.48 | 1605 | 6 | 14 |
3 | 501.84 | 51 | 8.77 | 1058 | 6 | 31 |
4 | 63.24 | 51 | 10.26 | 470 | 6 | 34 |
5 | -0.04 | 51 | 10.52 | 386 | 6 | 42 |
6 | -0.12 | 180 | 10.50 | 377 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.52 | 49 | 10.28 | 519 | 6 | 6 |
2 | 1000.76 | 101 | 7.55 | 1606 | 6 | 13 |
3 | 489.96 | 51 | 8.91 | 1044 | 6 | 32 |
4 | 61.40 | 51 | 10.30 | 475 | 6 | 33 |
5 | -0.00 | 51 | 10.51 | 398 | 6 | 33 |
6 | -0.12 | 180 | 10.51 | 386 | 6 | 49 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 49 | 10.41 | 519 | 6 | 7 |
2 | 1021.76 | 101 | 7.61 | 1631 | 6 | 15 |
3 | 358.80 | 51 | 9.36 | 881 | 6 | 35 |
4 | 37.88 | 51 | 10.40 | 440 | 6 | 32 |
5 | -0.04 | 51 | 10.58 | 371 | 6 | 33 |
6 | -0.12 | 181 | 10.54 | 376 | 6 | 50 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.32 | 47 | 10.54 | 500 | 6 | 6 |
2 | 1033.40 | 100 | 7.65 | 1649 | 6 | 14 |
3 | 506.12 | 51 | 8.99 | 1060 | 6 | 33 |
4 | 62.36 | 50 | 10.33 | 476 | 6 | 34 |
5 | -0.28 | 180 | 10.55 | 388 | 6 | 40 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.36 | 48 | 10.47 | 500 | 6 | 7 |
2 | 1905.24 | 101 | 5.86 | 2691 | 6 | 6 |
3 | 1811.00 | 51 | 6.33 | 2514 | 6 | 6 |
4 | 1692.80 | 51 | 6.67 | 2365 | 6 | 6 |
5 | 1536.48 | 51 | 6.77 | 2248 | 6 | 7 |
6 | 1219.00 | 51 | 7.48 | 1866 | 6 | 14 |
7 | 534.96 | 51 | 9.08 | 1081 | 6 | 35 |
8 | 72.12 | 51 | 10.39 | 469 | 6 | 34 |
9 | -0.00 | 51 | 10.59 | 385 | 6 | 43 |
10 | -0.08 | 180 | 10.59 | 382 | 6 | 44 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.48 | 49 | 10.47 | 500 | 6 | 6 |
2 | 992.76 | 101 | 7.90 | 1599 | 6 | 17 |
3 | 635.56 | 51 | 8.83 | 1200 | 6 | 29 |
4 | 43.44 | 51 | 10.43 | 451 | 6 | 32 |
5 | 0.08 | 181 | 10.61 | 365 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.68 | 49 | 10.41 | 519 | 6 | 6 |
2 | 1008.80 | 101 | 7.91 | 1630 | 6 | 15 |
3 | 634.16 | 51 | 8.82 | 1212 | 6 | 30 |
4 | 41.48 | 51 | 10.45 | 448 | 6 | 35 |
5 | -0.12 | 51 | 10.58 | 399 | 6 | 41 |
6 | -0.16 | 180 | 10.60 | 374 | 6 | 43 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.48 | 49 | 10.47 | 519 | 6 | 7 |
2 | 1011.76 | 101 | 7.96 | 1625 | 7 | 17 |
3 | 484.68 | 51 | 9.25 | 1026 | 6 | 32 |
4 | 20.00 | 51 | 10.54 | 409 | 6 | 32 |
5 | -0.04 | 51 | 10.62 | 382 | 6 | 36 |
6 | -0.12 | 180 | 10.60 | 382 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.92 | 45 | 10.54 | 500 | 6 | 6 |
2 | 1070.04 | 1 | 8.30 | 1730 | 6 | 6 |
3 | 1066.44 | 101 | 7.95 | 1683 | 6 | 15 |
4 | 541.56 | 51 | 9.19 | 1093 | 6 | 34 |
5 | 69.52 | 51 | 10.39 | 481 | 6 | 35 |
6 | -0.12 | 181 | 10.64 | 368 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.24 | 47 | 10.54 | 500 | 6 | 6 |
2 | 1056.20 | 1 | 8.18 | 1730 | 6 | 7 |
3 | 1910.36 | 101 | 6.46 | 2633 | 7 | 6 |
4 | 1812.96 | 51 | 6.77 | 2528 | 6 | 6 |
5 | 1675.96 | 51 | 6.98 | 2409 | 6 | 6 |
6 | 1511.48 | 51 | 7.28 | 2205 | 6 | 8 |
7 | 821.76 | 51 | 8.71 | 1412 | 6 | 29 |
8 | 147.20 | 51 | 10.23 | 597 | 6 | 35 |
9 | -0.00 | 51 | 10.67 | 379 | 6 | 34 |
10 | -0.00 | 180 | 10.66 | 371 | 6 | 52 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.04 | 49 | 10.54 | 519 | 6 | 6 |
2 | 1018.36 | 101 | 8.13 | 1619 | 6 | 18 |
3 | 325.60 | 51 | 9.72 | 834 | 6 | 36 |
4 | 28.80 | 51 | 10.55 | 421 | 6 | 34 |
5 | -0.08 | 51 | 10.66 | 383 | 6 | 34 |
6 | -0.16 | 181 | 10.62 | 385 | 6 | 47 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.16 | 48 | 10.47 | 519 | 6 | 6 |
2 | 1009.68 | 101 | 8.15 | 1625 | 6 | 19 |
3 | 319.40 | 51 | 9.73 | 814 | 6 | 35 |
4 | 21.20 | 51 | 10.59 | 407 | 6 | 34 |
5 | -0.24 | 51 | 10.65 | 385 | 6 | 37 |
6 | -0.12 | 180 | 10.63 | 381 | 6 | 46 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.64 | 48 | 10.60 | 500 | 6 | 6 |
2 | 1016.80 | 101 | 8.22 | 1624 | 6 | 19 |
3 | 485.12 | 51 | 9.43 | 1028 | 6 | 35 |
4 | 23.00 | 51 | 10.59 | 417 | 6 | 32 |
5 | -0.04 | 50 | 10.67 | 388 | 6 | 41 |
6 | -0.04 | 181 | 10.66 | 376 | 6 | 50 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.64 | 42 | 10.60 | 500 | 6 | 6 |
2 | 1135.60 | 3 | 8.30 | 1769 | 6 | 7 |
3 | 1104.92 | 101 | 8.07 | 1739 | 7 | 16 |
4 | 571.88 | 51 | 9.25 | 1137 | 6 | 34 |
5 | 78.56 | 51 | 10.46 | 497 | 6 | 36 |
6 | -0.12 | 51 | 10.70 | 371 | 6 | 37 |
7 | -0.20 | 180 | 10.66 | 378 | 6 | 42 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.52 | 44 | 10.60 | 500 | 6 | 6 |
2 | 1085.76 | 2 | 8.56 | 1730 | 6 | 7 |
3 | 1901.52 | 101 | 6.81 | 2639 | 7 | 6 |
4 | 1806.12 | 51 | 6.96 | 2563 | 6 | 6 |
5 | 1655.24 | 51 | 7.32 | 2364 | 6 | 7 |
6 | 1158.04 | 51 | 8.23 | 1817 | 6 | 20 |
7 | 476.64 | 51 | 9.60 | 1014 | 6 | 38 |
8 | 50.00 | 51 | 10.58 | 448 | 6 | 36 |
9 | -0.24 | 51 | 10.70 | 385 | 6 | 27 |
10 | -0.24 | 181 | 10.68 | 385 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.72 | 48 | 10.60 | 500 | 6 | 6 |
2 | 1016.00 | 101 | 8.37 | 1640 | 6 | 19 |
3 | 312.76 | 51 | 9.86 | 822 | 6 | 37 |
4 | 8.36 | 51 | 10.65 | 394 | 6 | 27 |
5 | -0.04 | 51 | 10.69 | 388 | 6 | 36 |
6 | -0.08 | 180 | 10.66 | 386 | 6 | 56 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.60 | 47 | 10.60 | 500 | 6 | 6 |
2 | 1032.68 | 101 | 8.43 | 1632 | 6 | 21 |
3 | 329.60 | 51 | 9.91 | 834 | 6 | 37 |
4 | 22.00 | 51 | 10.62 | 410 | 6 | 34 |
5 | -0.12 | 50 | 10.68 | 395 | 6 | 33 |
6 | -0.12 | 181 | 10.68 | 385 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.44 | 46 | 10.66 | 461 | 6 | 7 |
2 | 1037.28 | 101 | 8.46 | 1654 | 6 | 19 |
3 | 503.36 | 51 | 9.59 | 1039 | 6 | 35 |
4 | 46.04 | 51 | 10.59 | 444 | 6 | 36 |
5 | -0.16 | 51 | 10.70 | 392 | 6 | 30 |
6 | -0.08 | 180 | 10.69 | 384 | 6 | 48 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 39 | 10.66 | 461 | 6 | 6 |
2 | 1133.52 | 3 | 8.62 | 1750 | 6 | 7 |
3 | 1161.56 | 101 | 8.25 | 1797 | 7 | 19 |
4 | 636.84 | 51 | 9.31 | 1209 | 6 | 35 |
5 | 60.76 | 51 | 10.59 | 449 | 6 | 34 |
6 | 0.60 | 180 | 10.73 | 374 | 6 | 38 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 39 | 10.60 | 500 | 6 | 6 |
2 | 1211.76 | 5 | 7.98 | 1903 | 6 | 7 |
3 | 1901.32 | 100 | 6.50 | 2614 | 7 | 6 |
4 | 1803.72 | 51 | 6.92 | 2495 | 6 | 6 |
5 | 1657.12 | 51 | 7.37 | 2349 | 6 | 7 |
6 | 1495.64 | 51 | 7.69 | 2162 | 6 | 11 |
7 | 776.28 | 51 | 8.98 | 1370 | 6 | 32 |
8 | 106.04 | 51 | 10.47 | 527 | 6 | 36 |
9 | -0.00 | 51 | 10.74 | 374 | 6 | 37 |
10 | -0.04 | 180 | 10.71 | 369 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.92 | 44 | 10.60 | 519 | 6 | 7 |
2 | 1103.52 | 2 | 8.43 | 1826 | 6 | 8 |
3 | 1083.16 | 101 | 7.99 | 1712 | 8 | 15 |
4 | 569.36 | 51 | 9.21 | 1140 | 6 | 32 |
5 | 40.28 | 51 | 10.51 | 453 | 6 | 32 |
6 | -0.16 | 51 | 10.67 | 383 | 6 | 38 |
7 | -0.24 | 181 | 10.65 | 365 | 6 | 49 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.64 | 41 | 10.73 | 500 | 6 | 6 |
2 | 1112.44 | 2 | 8.69 | 1865 | 6 | 7 |
3 | 1116.76 | 101 | 8.38 | 1757 | 7 | 16 |
4 | 577.24 | 51 | 9.30 | 1155 | 6 | 35 |
5 | 46.84 | 51 | 10.55 | 460 | 6 | 33 |
6 | -0.08 | 181 | 10.67 | 389 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.24 | 38 | 11.24 | 480 | 6 | 6 |
2 | 1118.92 | 2 | 9.77 | 1807 | 6 | 9 |
3 | 1122.88 | 101 | 8.14 | 1739 | 9 | 15 |
4 | 590.68 | 51 | 9.36 | 1156 | 6 | 35 |
5 | 83.84 | 51 | 10.57 | 491 | 6 | 37 |
6 | -0.04 | 51 | 10.80 | 375 | 6 | 37 |
7 | -0.12 | 180 | 10.74 | 374 | 6 | 46 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.44 | 36 | 11.94 | 480 | 6 | 7 |
2 | 1102.60 | 2 | 11.43 | 1788 | 6 | 17 |
3 | 1089.24 | 101 | 8.02 | 1707 | 17 | 15 |
4 | 426.84 | 51 | 10.08 | 973 | 6 | 39 |
5 | 51.28 | 51 | 11.12 | 452 | 6 | 39 |
6 | -0.16 | 51 | 11.21 | 394 | 6 | 36 |
7 | -0.24 | 180 | 11.09 | 385 | 6 | 50 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.68 | 37 | 12.12 | 500 | 6 | 7 |
2 | 1106.80 | 2 | 10.86 | 1846 | 6 | 17 |
3 | 1917.76 | 101 | 7.15 | 2666 | 17 | 6 |
4 | 1793.84 | 51 | 8.17 | 2540 | 6 | 8 |
5 | 1468.12 | 51 | 8.62 | 2203 | 6 | 17 |
6 | 915.92 | 51 | 9.76 | 1537 | 6 | 37 |
7 | 152.00 | 51 | 11.28 | 610 | 6 | 46 |
8 | -0.16 | 181 | 11.66 | 392 | 6 | 44 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.76 | 38 | 12.57 | 538 | 6 | 7 |
2 | 1028.88 | 101 | 6.46 | 1594 | 7 | 9 |
3 | 869.08 | 51 | 9.09 | 1468 | 6 | 26 |
4 | 134.08 | 51 | 11.51 | 587 | 6 | 44 |
5 | -0.24 | 51 | 12.17 | 390 | 6 | 43 |
6 | -0.04 | 181 | 11.81 | 386 | 6 | 54 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.68 | 37 | 13.02 | 519 | 6 | 7 |
2 | 1020.80 | 100 | 6.69 | 1588 | 6 | 9 |
3 | 682.44 | 51 | 9.91 | 1275 | 6 | 36 |
4 | 67.00 | 51 | 12.40 | 487 | 6 | 45 |
5 | -0.20 | 51 | 12.88 | 394 | 6 | 51 |
6 | -0.16 | 180 | 12.14 | 383 | 6 | 52 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.88 | 37 | 13.14 | 519 | 6 | 7 |
2 | 1022.40 | 101 | 7.44 | 1610 | 6 | 16 |
3 | 667.44 | 51 | 10.47 | 1266 | 6 | 39 |
4 | 49.24 | 51 | 12.99 | 463 | 6 | 47 |
5 | -0.08 | 181 | 12.59 | 390 | 6 | 53 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.68 | 36 | 13.40 | 500 | 6 | 8 |
2 | 1032.24 | 101 | 7.80 | 1642 | 8 | 14 |
3 | 509.80 | 51 | 11.50 | 1098 | 6 | 47 |
4 | 20.96 | 51 | 13.34 | 421 | 6 | 49 |
5 | -0.20 | 51 | 13.41 | 407 | 6 | 49 |
6 | -0.24 | 180 | 12.49 | 388 | 6 | 52 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.80 | 36 | 13.53 | 519 | 6 | 7 |
2 | 1910.92 | 101 | 7.87 | 2623 | 7 | 6 |
3 | 1766.80 | 50 | 9.41 | 2522 | 6 | 13 |
4 | 1238.92 | 50 | 10.75 | 1944 | 6 | 36 |
5 | 317.36 | 50 | 12.62 | 865 | 6 | 60 |
6 | -0.28 | 181 | 13.08 | 396 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.76 | 36 | 13.59 | 538 | 6 | 7 |
2 | 1023.44 | 101 | 6.41 | 1588 | 7 | 9 |
3 | 857.28 | 51 | 10.18 | 1476 | 6 | 32 |
4 | 119.64 | 51 | 13.10 | 575 | 6 | 54 |
5 | -0.20 | 51 | 13.66 | 409 | 6 | 54 |
6 | -0.20 | 180 | 12.76 | 398 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.84 | 36 | 13.72 | 538 | 6 | 7 |
2 | 1015.68 | 101 | 6.61 | 1606 | 6 | 9 |
3 | 697.36 | 51 | 11.14 | 1319 | 6 | 41 |
4 | 57.88 | 51 | 13.50 | 500 | 6 | 52 |
5 | -0.24 | 51 | 13.76 | 407 | 6 | 54 |
6 | -0.16 | 180 | 12.94 | 398 | 6 | 65 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.16 | 36 | 13.78 | 538 | 6 | 7 |
2 | 1006.52 | 101 | 6.97 | 1589 | 7 | 12 |
3 | 664.52 | 51 | 11.30 | 1285 | 6 | 45 |
4 | 47.52 | 51 | 13.67 | 468 | 6 | 54 |
5 | -0.08 | 51 | 13.84 | 411 | 6 | 55 |
6 | -0.20 | 180 | 13.08 | 406 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.52 | 36 | 13.91 | 538 | 6 | 9 |
2 | 1010.20 | 100 | 7.53 | 1604 | 6 | 14 |
3 | 662.24 | 51 | 11.55 | 1301 | 6 | 46 |
4 | 43.16 | 51 | 13.74 | 489 | 6 | 58 |
5 | -0.20 | 51 | 13.93 | 415 | 6 | 58 |
6 | -0.20 | 181 | 13.26 | 402 | 6 | 65 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 36 | 13.91 | 519 | 6 | 8 |
2 | 1908.52 | 101 | 7.53 | 2673 | 6 | 6 |
3 | 1759.20 | 51 | 10.02 | 2522 | 6 | 16 |
4 | 1232.72 | 51 | 11.18 | 1969 | 6 | 40 |
5 | 261.68 | 51 | 13.22 | 809 | 6 | 64 |
6 | -0.20 | 50 | 14.04 | 411 | 6 | 59 |
7 | -0.16 | 181 | 13.43 | 404 | 6 | 78 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.20 | 36 | 13.91 | 538 | 6 | 8 |
2 | 1000.12 | 101 | 6.66 | 1592 | 8 | 9 |
3 | 829.00 | 51 | 10.77 | 1474 | 6 | 36 |
4 | 48.60 | 51 | 13.78 | 486 | 6 | 54 |
5 | -0.04 | 51 | 13.98 | 409 | 6 | 56 |
6 | -0.20 | 180 | 13.41 | 413 | 6 | 55 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.40 | 36 | 13.91 | 538 | 6 | 7 |
2 | 1006.44 | 101 | 6.99 | 1592 | 6 | 11 |
3 | 670.12 | 51 | 11.73 | 1304 | 6 | 48 |
4 | 52.16 | 51 | 13.80 | 485 | 6 | 57 |
5 | -0.12 | 51 | 13.96 | 420 | 6 | 60 |
6 | -0.20 | 180 | 13.51 | 404 | 6 | 74 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 36 | 13.91 | 538 | 6 | 6 |
2 | 1018.68 | 101 | 7.16 | 1617 | 6 | 11 |
3 | 677.36 | 51 | 11.73 | 1314 | 6 | 48 |
4 | 47.20 | 51 | 13.79 | 493 | 6 | 55 |
5 | -0.08 | 51 | 13.98 | 422 | 6 | 61 |
6 | -0.20 | 180 | 13.56 | 399 | 6 | 65 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.72 | 35 | 13.97 | 557 | 6 | 8 |
2 | 1028.08 | 101 | 7.69 | 1627 | 10 | 16 |
3 | 517.12 | 51 | 12.45 | 1114 | 6 | 53 |
4 | 42.28 | 51 | 13.86 | 476 | 6 | 59 |
5 | -0.12 | 51 | 14.05 | 421 | 6 | 66 |
6 | -0.20 | 180 | 13.59 | 405 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.88 | 36 | 13.97 | 519 | 6 | 7 |
2 | 1902.12 | 101 | 8.21 | 2687 | 7 | 7 |
3 | 1764.08 | 51 | 10.36 | 2568 | 6 | 21 |
4 | 1030.52 | 51 | 11.99 | 1745 | 6 | 50 |
5 | 105.68 | 51 | 13.83 | 556 | 6 | 62 |
6 | -0.16 | 51 | 14.12 | 414 | 6 | 56 |
7 | -0.12 | 180 | 13.73 | 400 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.40 | 36 | 14.04 | 519 | 6 | 8 |
2 | 1007.08 | 101 | 7.58 | 1603 | 6 | 15 |
3 | 655.92 | 51 | 12.18 | 1292 | 6 | 50 |
4 | 2.40 | 51 | 14.03 | 420 | 6 | 61 |
5 | -0.16 | 51 | 13.99 | 420 | 6 | 54 |
6 | -0.12 | 181 | 13.69 | 408 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 36 | 14.04 | 538 | 6 | 9 |
2 | 1183.28 | 100 | 6.46 | 1783 | 6 | 6 |
3 | 1152.80 | 51 | 10.94 | 1849 | 6 | 27 |
4 | 995.96 | 51 | 11.44 | 1682 | 6 | 40 |
5 | 85.24 | 51 | 13.84 | 532 | 6 | 60 |
6 | -0.04 | 51 | 14.09 | 409 | 6 | 58 |
7 | -0.08 | 180 | 13.76 | 403 | 6 | 75 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.24 | 36 | 13.97 | 519 | 6 | 8 |
2 | 1193.88 | 101 | 6.89 | 1815 | 6 | 8 |
3 | 1146.04 | 51 | 11.27 | 1835 | 6 | 33 |
4 | 811.36 | 51 | 12.18 | 1480 | 6 | 49 |
5 | 73.52 | 51 | 13.88 | 518 | 6 | 61 |
6 | -0.20 | 181 | 13.92 | 397 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.68 | 33 | 14.04 | 519 | 6 | 8 |
2 | 1065.92 | 1 | 11.18 | 1865 | 6 | 21 |
3 | 1240.56 | 100 | 6.67 | 1843 | 21 | 8 |
4 | 1184.20 | 51 | 11.27 | 1890 | 6 | 31 |
5 | 1022.24 | 51 | 11.72 | 1717 | 6 | 43 |
6 | 43.88 | 51 | 14.00 | 463 | 6 | 56 |
7 | -0.20 | 51 | 14.12 | 412 | 6 | 50 |
8 | -0.16 | 180 | 13.86 | 401 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.12 | 36 | 14.10 | 480 | 6 | 10 |
2 | 1928.68 | 60 | 4.53 | 2045 | 10 | 7 |
3 | 1997.40 | 25 | 10.30 | 2855 | 6 | 6 |
4 | 1920.36 | 25 | 10.92 | 2743 | 6 | 11 |
5 | 1792.76 | 25 | 11.31 | 2616 | 6 | 23 |
6 | 1639.04 | 25 | 11.68 | 2451 | 6 | 32 |
7 | 1141.60 | 25 | 12.44 | 1905 | 6 | 51 |
8 | 794.60 | 25 | 12.95 | 1495 | 6 | 62 |
9 | 123.28 | 25 | 13.93 | 593 | 6 | 59 |
10 | 13.12 | 25 | 14.13 | 428 | 6 | 52 |
11 | -0.04 | 181 | 14.00 | 402 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.92 | 36 | 14.10 | 480 | 6 | 8 |
2 | 1926.48 | 60 | 4.53 | 2042 | 8 | 7 |
3 | 1978.72 | 25 | 10.32 | 2843 | 6 | 6 |
4 | 1898.12 | 25 | 10.95 | 2716 | 6 | 11 |
5 | 1781.76 | 25 | 11.40 | 2589 | 6 | 23 |
6 | 1629.60 | 25 | 11.66 | 2455 | 6 | 33 |
7 | 1127.36 | 25 | 12.45 | 1903 | 6 | 52 |
8 | 604.60 | 25 | 13.24 | 1234 | 6 | 64 |
9 | 109.84 | 25 | 13.91 | 576 | 6 | 59 |
10 | -0.36 | 180 | 14.01 | 396 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.24 | 36 | 14.10 | 500 | 6 | 8 |
2 | 1929.32 | 60 | 4.55 | 2027 | 8 | 7 |
3 | 1992.12 | 25 | 10.32 | 2836 | 6 | 6 |
4 | 1915.76 | 25 | 10.98 | 2734 | 6 | 11 |
5 | 1788.48 | 25 | 11.37 | 2620 | 6 | 24 |
6 | 1627.52 | 25 | 11.74 | 2443 | 6 | 33 |
7 | 1290.68 | 25 | 12.33 | 2059 | 6 | 48 |
8 | 580.40 | 25 | 13.26 | 1220 | 6 | 66 |
9 | 113.68 | 25 | 13.93 | 578 | 6 | 59 |
10 | -0.00 | 26 | 14.18 | 410 | 6 | 52 |
11 | -0.08 | 181 | 13.99 | 400 | 6 | 60 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.88 | 36 | 14.04 | 519 | 6 | 9 |
2 | 1929.20 | 60 | 4.53 | 1986 | 9 | 7 |
3 | 1986.52 | 25 | 10.22 | 2797 | 6 | 6 |
4 | 1908.56 | 25 | 10.97 | 2705 | 6 | 11 |
5 | 1791.84 | 25 | 11.42 | 2591 | 6 | 22 |
6 | 1645.72 | 25 | 11.74 | 2443 | 6 | 33 |
7 | 1134.52 | 25 | 12.50 | 1901 | 6 | 52 |
8 | 617.24 | 25 | 13.22 | 1251 | 6 | 66 |
9 | 122.64 | 25 | 13.90 | 593 | 6 | 58 |
10 | 24.72 | 26 | 14.10 | 438 | 6 | 54 |
11 | -0.08 | 26 | 14.19 | 412 | 6 | 53 |
12 | -0.12 | 181 | 14.00 | 403 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.12 | 36 | 14.10 | 500 | 6 | 8 |
2 | 1926.36 | 60 | 4.53 | 2051 | 8 | 7 |
3 | 1985.60 | 25 | 9.71 | 2843 | 6 | 6 |
4 | 1918.20 | 25 | 10.98 | 2722 | 6 | 12 |
5 | 1804.52 | 25 | 11.32 | 2636 | 6 | 23 |
6 | 1482.20 | 25 | 11.99 | 2286 | 6 | 38 |
7 | 1146.40 | 25 | 12.50 | 1909 | 6 | 51 |
8 | 630.00 | 25 | 13.18 | 1276 | 6 | 65 |
9 | 128.08 | 25 | 13.88 | 597 | 6 | 57 |
10 | -0.08 | 26 | 14.17 | 410 | 6 | 45 |
11 | -0.12 | 181 | 13.99 | 405 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.96 | 36 | 14.10 | 480 | 6 | 9 |
2 | 1511.28 | 61 | 6.74 | 2130 | 6 | 6 |
3 | 1529.40 | 26 | 11.53 | 2280 | 6 | 22 |
4 | 1418.04 | 25 | 11.98 | 2192 | 6 | 34 |
5 | 1282.80 | 25 | 12.28 | 2034 | 6 | 43 |
6 | 588.48 | 25 | 13.25 | 1213 | 6 | 62 |
7 | 240.48 | 25 | 13.64 | 788 | 6 | 62 |
8 | 18.24 | 25 | 14.06 | 449 | 6 | 52 |
9 | 0.08 | 26 | 14.11 | 422 | 6 | 56 |
10 | -0.04 | 181 | 13.98 | 406 | 6 | 63 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.80 | 36 | 14.04 | 480 | 6 | 8 |
2 | 1510.96 | 61 | 6.88 | 2139 | 6 | 6 |
3 | 1520.76 | 26 | 11.60 | 2300 | 6 | 24 |
4 | 1394.64 | 25 | 12.12 | 2149 | 6 | 36 |
5 | 1240.44 | 25 | 12.43 | 1974 | 6 | 45 |
6 | 886.12 | 25 | 12.85 | 1582 | 6 | 57 |
7 | 177.20 | 25 | 13.78 | 684 | 6 | 58 |
8 | 32.52 | 25 | 14.08 | 461 | 6 | 53 |
9 | -0.16 | 26 | 14.12 | 419 | 6 | 59 |
10 | -0.28 | 181 | 13.99 | 407 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.72 | 35 | 14.04 | 519 | 6 | 9 |
2 | 1505.08 | 61 | 6.55 | 2149 | 6 | 6 |
3 | 1547.64 | 25 | 11.70 | 2316 | 6 | 22 |
4 | 1438.76 | 25 | 12.03 | 2211 | 6 | 34 |
5 | 1282.20 | 25 | 12.31 | 2049 | 6 | 41 |
6 | 1117.88 | 25 | 12.53 | 1870 | 6 | 51 |
7 | 208.32 | 25 | 13.77 | 720 | 6 | 59 |
8 | 43.12 | 25 | 14.04 | 470 | 6 | 49 |
9 | -0.04 | 181 | 14.06 | 399 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.00 | 30 | 14.10 | 519 | 6 | 8 |
2 | 1122.84 | 3 | 11.81 | 1903 | 6 | 21 |
3 | 1107.16 | 60 | 8.65 | 1743 | 21 | 19 |
4 | 977.40 | 25 | 12.51 | 1712 | 6 | 49 |
5 | 457.20 | 25 | 13.37 | 1051 | 6 | 63 |
6 | 115.80 | 25 | 13.89 | 589 | 6 | 57 |
7 | -0.04 | 181 | 13.98 | 413 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.32 | 36 | 14.10 | 500 | 6 | 8 |
2 | 1929.64 | 60 | 4.53 | 1914 | 8 | 7 |
3 | 1992.00 | 25 | 10.49 | 2859 | 6 | 6 |
4 | 1912.56 | 25 | 11.23 | 2749 | 6 | 13 |
5 | 1792.84 | 25 | 11.53 | 2653 | 6 | 25 |
6 | 1637.40 | 25 | 11.91 | 2443 | 6 | 34 |
7 | 1110.52 | 25 | 12.63 | 1857 | 6 | 55 |
8 | 598.68 | 25 | 13.27 | 1236 | 6 | 64 |
9 | 110.08 | 25 | 13.96 | 557 | 6 | 55 |
10 | -0.00 | 26 | 14.15 | 406 | 6 | 46 |
11 | -0.00 | 181 | 14.05 | 400 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.84 | 36 | 14.04 | 500 | 6 | 9 |
2 | 1927.24 | 60 | 4.52 | 1957 | 9 | 7 |
3 | 1994.60 | 25 | 10.74 | 2799 | 6 | 7 |
4 | 1923.84 | 25 | 11.24 | 2766 | 6 | 14 |
5 | 1797.88 | 25 | 11.56 | 2661 | 6 | 25 |
6 | 1483.04 | 25 | 12.14 | 2291 | 6 | 40 |
7 | 983.20 | 25 | 12.77 | 1716 | 6 | 57 |
8 | 457.52 | 25 | 13.42 | 1051 | 6 | 65 |
9 | 70.84 | 25 | 13.96 | 513 | 6 | 54 |
10 | -0.12 | 26 | 14.14 | 419 | 6 | 54 |
11 | -0.12 | 181 | 14.05 | 401 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.04 | 36 | 13.97 | 500 | 6 | 9 |
2 | 1928.88 | 60 | 4.53 | 1926 | 9 | 7 |
3 | 2001.84 | 25 | 10.49 | 2853 | 6 | 6 |
4 | 1937.84 | 25 | 11.14 | 2803 | 6 | 14 |
5 | 1821.36 | 25 | 11.61 | 2653 | 6 | 25 |
6 | 1663.76 | 25 | 11.90 | 2472 | 6 | 34 |
7 | 1131.36 | 25 | 12.58 | 1888 | 6 | 54 |
8 | 613.20 | 25 | 13.17 | 1270 | 6 | 66 |
9 | 106.12 | 25 | 13.91 | 568 | 6 | 57 |
10 | -0.16 | 181 | 14.06 | 402 | 6 | 58 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.00 | 36 | 14.10 | 461 | 6 | 8 |
2 | 1930.04 | 60 | 4.52 | 1947 | 8 | 7 |
3 | 1995.40 | 25 | 10.37 | 2837 | 6 | 6 |
4 | 1922.56 | 25 | 11.29 | 2745 | 6 | 13 |
5 | 1795.72 | 25 | 11.56 | 2641 | 6 | 25 |
6 | 1633.28 | 25 | 11.90 | 2457 | 6 | 35 |
7 | 1125.76 | 25 | 12.59 | 1876 | 6 | 55 |
8 | 588.76 | 25 | 13.25 | 1220 | 6 | 67 |
9 | 106.40 | 25 | 13.93 | 568 | 6 | 55 |
10 | -0.08 | 181 | 14.05 | 405 | 6 | 78 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.12 | 36 | 13.91 | 500 | 6 | 8 |
2 | 1927.52 | 60 | 4.53 | 1993 | 8 | 7 |
3 | 1989.32 | 25 | 10.16 | 2822 | 6 | 6 |
4 | 1913.20 | 25 | 11.16 | 2759 | 6 | 14 |
5 | 1796.48 | 25 | 11.62 | 2614 | 6 | 27 |
6 | 1657.52 | 25 | 11.86 | 2493 | 6 | 34 |
7 | 1152.84 | 25 | 12.60 | 1911 | 6 | 54 |
8 | 475.24 | 25 | 13.38 | 1076 | 6 | 67 |
9 | 140.32 | 25 | 13.87 | 613 | 6 | 59 |
10 | 7.76 | 25 | 14.10 | 414 | 6 | 50 |
11 | -0.00 | 26 | 14.17 | 408 | 6 | 58 |
12 | -0.04 | 181 | 14.04 | 401 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.92 | 35 | 14.04 | 480 | 6 | 9 |
2 | 1502.64 | 61 | 6.87 | 2128 | 6 | 6 |
3 | 1512.40 | 25 | 11.80 | 2266 | 6 | 24 |
4 | 1398.40 | 25 | 12.18 | 2161 | 6 | 35 |
5 | 1236.88 | 25 | 12.31 | 2039 | 6 | 44 |
6 | 574.88 | 25 | 13.20 | 1215 | 6 | 62 |
7 | 238.88 | 25 | 13.64 | 782 | 6 | 62 |
8 | -0.00 | 26 | 14.12 | 419 | 6 | 49 |
9 | -0.04 | 181 | 13.99 | 406 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.24 | 34 | 13.91 | 538 | 6 | 10 |
2 | 1057.56 | 1 | 11.43 | 1769 | 6 | 12 |
3 | 1515.36 | 61 | 7.06 | 2166 | 12 | 6 |
4 | 1499.84 | 25 | 11.93 | 2268 | 6 | 27 |
5 | 1383.64 | 25 | 12.21 | 2155 | 6 | 38 |
6 | 1220.64 | 25 | 12.50 | 1964 | 6 | 45 |
7 | 697.64 | 25 | 13.10 | 1358 | 6 | 62 |
8 | 175.64 | 25 | 13.80 | 666 | 6 | 60 |
9 | 34.60 | 25 | 14.03 | 457 | 6 | 49 |
10 | -0.12 | 26 | 14.17 | 411 | 6 | 51 |
11 | -0.08 | 181 | 14.01 | 408 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.96 | 28 | 14.10 | 480 | 6 | 8 |
2 | 1223.92 | 5 | 11.56 | 1961 | 6 | 24 |
3 | 1504.40 | 61 | 6.62 | 2107 | 24 | 6 |
4 | 1551.84 | 25 | 11.66 | 2336 | 6 | 22 |
5 | 1448.36 | 25 | 12.08 | 2219 | 6 | 36 |
6 | 1300.44 | 25 | 12.36 | 2059 | 6 | 44 |
7 | 948.80 | 25 | 12.76 | 1670 | 6 | 56 |
8 | 236.36 | 25 | 13.69 | 761 | 6 | 63 |
9 | 43.32 | 25 | 13.97 | 486 | 6 | 54 |
10 | -0.12 | 181 | 14.04 | 399 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.04 | 28 | 14.04 | 480 | 6 | 8 |
2 | 1107.60 | 2 | 12.12 | 1826 | 6 | 17 |
3 | 1186.92 | 60 | 8.08 | 1801 | 17 | 13 |
4 | 1036.12 | 25 | 12.44 | 1762 | 6 | 48 |
5 | 534.88 | 25 | 13.25 | 1159 | 6 | 61 |
6 | 96.52 | 25 | 13.89 | 545 | 6 | 55 |
7 | 4.80 | 25 | 14.06 | 416 | 6 | 50 |
8 | -0.12 | 26 | 14.15 | 408 | 6 | 51 |
9 | -0.08 | 181 | 14.02 | 389 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.68 | 36 | 14.04 | 480 | 6 | 10 |
2 | 1955.20 | 60 | 4.46 | 1773 | 10 | 7 |
3 | 2022.80 | 25 | 9.18 | 2865 | 6 | 6 |
4 | 1956.40 | 25 | 11.00 | 2787 | 6 | 10 |
5 | 1833.28 | 25 | 11.59 | 2645 | 6 | 23 |
6 | 1688.04 | 25 | 11.98 | 2478 | 6 | 35 |
7 | 1349.80 | 25 | 12.37 | 2128 | 6 | 47 |
8 | 664.80 | 25 | 13.17 | 1307 | 6 | 63 |
9 | 152.36 | 25 | 13.78 | 645 | 6 | 60 |
10 | 26.60 | 25 | 14.03 | 449 | 6 | 54 |
11 | -0.12 | 26 | 14.13 | 417 | 6 | 55 |
12 | -0.04 | 181 | 14.03 | 400 | 6 | 71 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.68 | 36 | 14.10 | 480 | 6 | 7 |
2 | 1956.64 | 60 | 4.51 | 1814 | 7 | 7 |
3 | 2030.12 | 25 | 9.49 | 2866 | 6 | 6 |
4 | 1959.84 | 25 | 11.09 | 2792 | 6 | 11 |
5 | 1841.40 | 25 | 11.60 | 2682 | 6 | 23 |
6 | 1682.44 | 25 | 11.91 | 2526 | 6 | 34 |
7 | 1341.88 | 25 | 12.37 | 2130 | 6 | 47 |
8 | 798.36 | 25 | 13.01 | 1480 | 6 | 63 |
9 | 240.84 | 26 | 13.68 | 754 | 6 | 63 |
10 | 3.20 | 25 | 14.08 | 410 | 6 | 55 |
11 | -0.28 | 25 | 14.15 | 412 | 6 | 56 |
12 | -0.32 | 180 | 14.03 | 402 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.12 | 36 | 14.04 | 519 | 6 | 8 |
2 | 1956.44 | 60 | 4.51 | 1829 | 8 | 7 |
3 | 2008.96 | 25 | 9.77 | 2816 | 6 | 6 |
4 | 1929.64 | 25 | 11.15 | 2755 | 6 | 11 |
5 | 1804.84 | 25 | 11.63 | 2659 | 6 | 24 |
6 | 1652.00 | 25 | 11.98 | 2472 | 6 | 34 |
7 | 1147.48 | 25 | 12.58 | 1922 | 6 | 53 |
8 | 619.96 | 25 | 13.16 | 1288 | 6 | 64 |
9 | 126.28 | 25 | 13.83 | 599 | 6 | 58 |
10 | 7.00 | 25 | 14.11 | 420 | 6 | 52 |
11 | -0.20 | 26 | 14.14 | 420 | 6 | 57 |
12 | -0.24 | 181 | 14.03 | 398 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.44 | 36 | 13.97 | 538 | 6 | 9 |
2 | 1958.08 | 60 | 4.48 | 1804 | 9 | 7 |
3 | 2023.40 | 25 | 9.70 | 2816 | 6 | 6 |
4 | 1950.76 | 25 | 11.21 | 2726 | 6 | 11 |
5 | 1830.84 | 25 | 11.65 | 2670 | 6 | 25 |
6 | 1669.04 | 25 | 11.97 | 2497 | 6 | 35 |
7 | 1157.92 | 25 | 12.57 | 1928 | 6 | 54 |
8 | 804.40 | 26 | 12.96 | 1496 | 6 | 63 |
9 | 119.32 | 25 | 13.87 | 593 | 6 | 60 |
10 | -0.08 | 25 | 14.11 | 415 | 6 | 51 |
11 | -0.04 | 180 | 14.07 | 388 | 6 | 63 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.68 | 36 | 14.10 | 461 | 6 | 8 |
2 | 1954.28 | 60 | 4.53 | 1923 | 8 | 7 |
3 | 2018.04 | 25 | 9.92 | 2878 | 6 | 6 |
4 | 1941.24 | 25 | 11.32 | 2755 | 6 | 13 |
5 | 1820.28 | 25 | 11.66 | 2659 | 6 | 26 |
6 | 1662.08 | 25 | 11.98 | 2486 | 6 | 36 |
7 | 1153.76 | 25 | 12.62 | 1893 | 6 | 54 |
8 | 621.40 | 26 | 13.11 | 1279 | 6 | 66 |
9 | 116.92 | 25 | 13.84 | 599 | 6 | 58 |
10 | -0.12 | 26 | 14.15 | 408 | 6 | 46 |
11 | -0.08 | 181 | 14.03 | 405 | 6 | 65 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.40 | 36 | 14.10 | 461 | 6 | 8 |
2 | 1953.40 | 30 | 4.53 | 1733 | 8 | 7 |
3 | 2009.84 | 25 | 9.05 | 2816 | 6 | 6 |
4 | 1936.36 | 25 | 10.77 | 2774 | 6 | 8 |
5 | 1817.56 | 25 | 11.44 | 2661 | 6 | 22 |
6 | 1673.64 | 25 | 11.84 | 2489 | 6 | 34 |
7 | 1168.36 | 25 | 12.51 | 1916 | 6 | 50 |
8 | 671.92 | 25 | 13.12 | 1322 | 6 | 62 |
9 | 160.16 | 26 | 13.74 | 655 | 6 | 60 |
10 | -0.04 | 26 | 14.11 | 410 | 6 | 52 |
11 | -0.12 | 181 | 13.99 | 399 | 6 | 58 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.60 | 36 | 13.97 | 480 | 6 | 8 |
2 | 1961.24 | 30 | 4.53 | 1741 | 8 | 7 |
3 | 2031.96 | 25 | 8.97 | 2824 | 6 | 6 |
4 | 1961.84 | 25 | 10.63 | 2774 | 6 | 7 |
5 | 1839.56 | 25 | 11.35 | 2670 | 6 | 21 |
6 | 1688.00 | 25 | 11.76 | 2505 | 6 | 32 |
7 | 1213.64 | 25 | 12.44 | 1963 | 6 | 50 |
8 | 709.56 | 26 | 13.04 | 1357 | 6 | 62 |
9 | 165.56 | 25 | 13.75 | 674 | 6 | 62 |
10 | 27.32 | 25 | 14.02 | 455 | 6 | 55 |
11 | -0.04 | 26 | 14.12 | 419 | 6 | 52 |
12 | -0.24 | 181 | 13.96 | 406 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 36 | 14.04 | 480 | 6 | 9 |
2 | 1957.64 | 30 | 4.51 | 1777 | 9 | 7 |
3 | 2008.16 | 25 | 9.07 | 2732 | 6 | 6 |
4 | 1949.36 | 25 | 10.63 | 2747 | 6 | 7 |
5 | 1824.52 | 25 | 11.44 | 2620 | 6 | 21 |
6 | 1674.84 | 25 | 11.79 | 2491 | 6 | 32 |
7 | 1177.20 | 25 | 12.47 | 1934 | 6 | 51 |
8 | 669.48 | 25 | 13.08 | 1328 | 6 | 63 |
9 | 147.08 | 25 | 13.74 | 643 | 6 | 61 |
10 | 26.56 | 25 | 14.01 | 457 | 6 | 55 |
11 | -0.12 | 25 | 14.10 | 422 | 6 | 60 |
12 | -0.08 | 180 | 13.98 | 403 | 6 | 71 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.24 | 36 | 14.04 | 480 | 6 | 10 |
2 | 1953.92 | 30 | 4.53 | 1776 | 10 | 7 |
3 | 2027.88 | 25 | 8.92 | 2778 | 6 | 6 |
4 | 1961.48 | 25 | 10.42 | 2793 | 6 | 7 |
5 | 1853.84 | 25 | 11.25 | 2699 | 6 | 19 |
6 | 1711.64 | 25 | 11.73 | 2534 | 6 | 32 |
7 | 1201.44 | 25 | 12.43 | 1963 | 6 | 50 |
8 | 715.88 | 25 | 13.02 | 1380 | 6 | 63 |
9 | 191.64 | 25 | 13.69 | 707 | 6 | 64 |
10 | 36.48 | 25 | 13.99 | 468 | 6 | 56 |
11 | -0.16 | 26 | 14.15 | 412 | 6 | 61 |
12 | -0.24 | 181 | 13.96 | 406 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.56 | 36 | 14.04 | 461 | 6 | 9 |
2 | 1957.48 | 30 | 4.52 | 1802 | 9 | 7 |
3 | 2007.80 | 25 | 8.98 | 2784 | 6 | 6 |
4 | 1946.16 | 25 | 10.41 | 2809 | 6 | 8 |
5 | 1838.24 | 25 | 11.35 | 2668 | 6 | 20 |
6 | 1702.48 | 25 | 11.80 | 2515 | 6 | 32 |
7 | 1205.48 | 25 | 12.43 | 1976 | 6 | 50 |
8 | 704.24 | 25 | 13.01 | 1382 | 6 | 62 |
9 | 183.80 | 25 | 13.67 | 703 | 6 | 63 |
10 | 14.60 | 25 | 14.03 | 442 | 6 | 53 |
11 | -0.08 | 181 | 13.99 | 408 | 6 | 72 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.44 | 36 | 14.10 | 461 | 6 | 10 |
2 | 1956.80 | 30 | 4.52 | 1794 | 6 | 7 |
3 | 2025.72 | 25 | 8.82 | 2818 | 6 | 6 |
4 | 1953.28 | 26 | 10.29 | 2784 | 6 | 7 |
5 | 1836.88 | 25 | 11.36 | 2666 | 6 | 19 |
6 | 1692.76 | 26 | 11.65 | 2527 | 6 | 31 |
7 | 1346.48 | 25 | 12.31 | 2124 | 6 | 47 |
8 | 810.04 | 25 | 12.95 | 1493 | 6 | 61 |
9 | 143.40 | 25 | 13.78 | 632 | 6 | 57 |
10 | 26.36 | 25 | 14.03 | 455 | 6 | 55 |
11 | -0.00 | 26 | 14.15 | 413 | 6 | 52 |
12 | -0.12 | 181 | 14.00 | 407 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.76 | 36 | 14.04 | 500 | 6 | 9 |
2 | 1958.92 | 30 | 4.52 | 1806 | 9 | 7 |
3 | 2023.68 | 25 | 8.72 | 2855 | 6 | 6 |
4 | 1967.64 | 25 | 10.51 | 2772 | 6 | 7 |
5 | 1866.56 | 25 | 11.38 | 2687 | 6 | 20 |
6 | 1716.20 | 25 | 11.80 | 2526 | 6 | 32 |
7 | 1205.20 | 25 | 12.49 | 1949 | 6 | 52 |
8 | 868.28 | 25 | 12.89 | 1557 | 6 | 61 |
9 | 169.40 | 26 | 13.68 | 674 | 6 | 60 |
10 | 13.36 | 25 | 14.04 | 426 | 6 | 52 |
11 | -0.20 | 181 | 14.03 | 396 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.40 | 36 | 14.04 | 480 | 6 | 9 |
2 | 1959.64 | 30 | 4.52 | 1814 | 9 | 7 |
3 | 2015.24 | 25 | 8.94 | 2826 | 6 | 6 |
4 | 1945.04 | 25 | 10.67 | 2761 | 6 | 9 |
5 | 1838.52 | 25 | 11.49 | 2649 | 6 | 21 |
6 | 1703.76 | 25 | 11.89 | 2501 | 6 | 32 |
7 | 1214.76 | 25 | 12.49 | 1980 | 6 | 50 |
8 | 889.56 | 25 | 12.84 | 1597 | 6 | 60 |
9 | 171.52 | 25 | 13.73 | 664 | 6 | 61 |
10 | 32.76 | 25 | 14.01 | 455 | 6 | 54 |
11 | 0.36 | 180 | 14.02 | 397 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.32 | 36 | 13.97 | 500 | 6 | 9 |
2 | 1957.24 | 30 | 4.52 | 1764 | 9 | 7 |
3 | 2019.56 | 25 | 8.82 | 2803 | 6 | 6 |
4 | 1952.28 | 25 | 10.63 | 2774 | 6 | 7 |
5 | 1828.76 | 25 | 11.44 | 2674 | 6 | 21 |
6 | 1680.12 | 25 | 11.90 | 2497 | 6 | 34 |
7 | 1349.64 | 25 | 12.32 | 2155 | 6 | 45 |
8 | 822.44 | 25 | 12.95 | 1507 | 6 | 62 |
9 | 146.80 | 25 | 13.76 | 639 | 6 | 60 |
10 | 28.24 | 25 | 14.05 | 451 | 6 | 51 |
11 | -0.12 | 26 | 14.17 | 412 | 6 | 53 |
12 | -0.04 | 181 | 14.02 | 399 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.04 | 36 | 13.97 | 519 | 6 | 8 |
2 | 1955.80 | 30 | 4.52 | 1823 | 8 | 7 |
3 | 2015.60 | 25 | 9.00 | 2813 | 6 | 6 |
4 | 1944.28 | 25 | 10.80 | 2791 | 6 | 9 |
5 | 1825.12 | 25 | 11.54 | 2672 | 6 | 24 |
6 | 1680.00 | 25 | 11.92 | 2514 | 6 | 35 |
7 | 1158.04 | 25 | 12.59 | 1911 | 6 | 53 |
8 | 642.56 | 26 | 13.07 | 1305 | 6 | 66 |
9 | 129.28 | 25 | 13.81 | 609 | 6 | 61 |
10 | -0.20 | 26 | 14.13 | 401 | 6 | 54 |
11 | -0.24 | 181 | 14.01 | 393 | 6 | 74 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.60 | 36 | 13.91 | 538 | 6 | 8 |
2 | 1959.00 | 30 | 4.53 | 1898 | 6 | 7 |
3 | 2011.72 | 25 | 9.35 | 2797 | 6 | 6 |
4 | 1936.72 | 25 | 11.15 | 2772 | 6 | 12 |
5 | 1820.08 | 25 | 11.73 | 2651 | 6 | 26 |
6 | 1656.00 | 25 | 12.05 | 2490 | 6 | 37 |
7 | 1147.68 | 25 | 12.60 | 1922 | 6 | 54 |
8 | 794.68 | 25 | 12.99 | 1484 | 6 | 65 |
9 | 110.40 | 25 | 13.84 | 582 | 6 | 60 |
10 | -0.00 | 26 | 14.15 | 401 | 6 | 47 |
11 | -0.04 | 181 | 14.02 | 401 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.36 | 36 | 13.97 | 500 | 6 | 9 |
2 | 1952.60 | 30 | 4.53 | 1879 | 9 | 7 |
3 | 2012.24 | 25 | 9.13 | 2832 | 6 | 6 |
4 | 1952.16 | 25 | 11.18 | 2803 | 6 | 11 |
5 | 1841.20 | 25 | 11.70 | 2690 | 6 | 25 |
6 | 1679.96 | 25 | 12.00 | 2514 | 6 | 35 |
7 | 1172.64 | 25 | 12.60 | 1915 | 6 | 53 |
8 | 484.40 | 25 | 13.31 | 1089 | 6 | 67 |
9 | 136.40 | 25 | 13.75 | 636 | 6 | 62 |
10 | -0.08 | 26 | 14.09 | 419 | 6 | 50 |
11 | -0.16 | 181 | 13.98 | 401 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.04 | 36 | 14.04 | 500 | 6 | 9 |
2 | 1950.80 | 20 | 4.51 | 1697 | 9 | 7 |
3 | 2001.20 | 21 | 8.54 | 2807 | 6 | 6 |
4 | 1974.12 | 21 | 10.79 | 2815 | 6 | 9 |
5 | 1887.92 | 21 | 11.59 | 2738 | 6 | 21 |
6 | 1762.60 | 20 | 12.00 | 2600 | 6 | 36 |
7 | 1631.52 | 20 | 12.21 | 2456 | 6 | 40 |
8 | 1213.64 | 20 | 12.64 | 1992 | 6 | 55 |
9 | 673.28 | 21 | 13.13 | 1341 | 6 | 64 |
10 | 152.80 | 21 | 13.74 | 655 | 6 | 58 |
11 | 29.56 | 21 | 14.06 | 452 | 6 | 54 |
12 | -0.04 | 21 | 14.13 | 422 | 6 | 50 |
13 | -0.16 | 200 | 14.00 | 393 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.08 | 36 | 13.85 | 538 | 6 | 9 |
2 | 1960.36 | 20 | 4.51 | 1716 | 9 | 7 |
3 | 2024.44 | 21 | 8.81 | 2766 | 6 | 6 |
4 | 1993.36 | 21 | 10.89 | 2847 | 6 | 8 |
5 | 1903.80 | 20 | 11.68 | 2783 | 6 | 22 |
6 | 1779.20 | 21 | 11.92 | 2619 | 6 | 31 |
7 | 1511.28 | 20 | 12.38 | 2312 | 6 | 43 |
8 | 1108.32 | 21 | 12.66 | 1871 | 6 | 57 |
9 | 692.04 | 21 | 13.09 | 1371 | 6 | 66 |
10 | 131.96 | 21 | 13.84 | 615 | 6 | 59 |
11 | -0.12 | 21 | 14.17 | 401 | 6 | 55 |
12 | -0.16 | 200 | 13.99 | 393 | 6 | 72 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.40 | 36 | 14.04 | 500 | 6 | 9 |
2 | 1950.84 | 20 | 4.50 | 1705 | 9 | 7 |
3 | 2011.96 | 21 | 8.86 | 2790 | 6 | 6 |
4 | 1970.20 | 21 | 11.17 | 2792 | 6 | 10 |
5 | 1885.72 | 20 | 11.84 | 2720 | 6 | 25 |
6 | 1787.64 | 20 | 12.07 | 2622 | 6 | 35 |
7 | 1393.80 | 21 | 12.45 | 2164 | 6 | 47 |
8 | 1263.00 | 21 | 12.56 | 2018 | 6 | 53 |
9 | 546.32 | 21 | 13.29 | 1163 | 6 | 67 |
10 | 130.96 | 21 | 13.84 | 608 | 6 | 60 |
11 | -0.04 | 20 | 14.17 | 405 | 6 | 50 |
12 | -0.16 | 200 | 13.99 | 397 | 6 | 74 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.80 | 36 | 13.97 | 500 | 6 | 10 |
2 | 1957.16 | 20 | 4.56 | 1632 | 10 | 7 |
3 | 2011.12 | 21 | 8.91 | 2723 | 6 | 6 |
4 | 1969.24 | 21 | 11.12 | 2805 | 6 | 9 |
5 | 1878.72 | 21 | 11.74 | 2700 | 6 | 23 |
6 | 1762.40 | 21 | 12.02 | 2570 | 6 | 33 |
7 | 1641.12 | 20 | 12.26 | 2451 | 6 | 41 |
8 | 1510.44 | 21 | 12.37 | 2283 | 6 | 45 |
9 | 626.40 | 21 | 13.21 | 1264 | 6 | 65 |
10 | 202.88 | 21 | 13.70 | 719 | 6 | 65 |
11 | 40.00 | 21 | 14.01 | 465 | 6 | 53 |
12 | -0.04 | 21 | 14.16 | 411 | 6 | 57 |
13 | -0.04 | 200 | 13.97 | 400 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 36 | 13.91 | 538 | 6 | 10 |
2 | 1950.76 | 20 | 4.50 | 1676 | 6 | 7 |
3 | 1998.12 | 20 | 9.07 | 2785 | 6 | 6 |
4 | 1960.28 | 20 | 11.42 | 2790 | 6 | 11 |
5 | 1881.12 | 20 | 11.85 | 2732 | 6 | 24 |
6 | 1774.28 | 21 | 11.97 | 2617 | 6 | 32 |
7 | 1505.64 | 21 | 12.31 | 2320 | 6 | 43 |
8 | 1232.56 | 20 | 12.63 | 2018 | 6 | 54 |
9 | 655.12 | 21 | 13.16 | 1305 | 6 | 65 |
10 | 223.32 | 21 | 13.66 | 753 | 6 | 64 |
11 | 40.16 | 21 | 14.04 | 465 | 6 | 56 |
12 | -0.16 | 21 | 14.13 | 418 | 6 | 57 |
13 | -0.20 | 200 | 13.98 | 395 | 6 | 77 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.64 | 36 | 13.91 | 557 | 6 | 9 |
2 | 1953.08 | 20 | 4.50 | 1623 | 9 | 7 |
3 | 2014.56 | 21 | 8.67 | 2847 | 6 | 6 |
4 | 1970.84 | 21 | 11.39 | 2802 | 6 | 12 |
5 | 1870.84 | 21 | 11.76 | 2741 | 6 | 25 |
6 | 1748.60 | 20 | 12.11 | 2586 | 6 | 35 |
7 | 1619.36 | 21 | 12.26 | 2426 | 6 | 41 |
8 | 1053.04 | 21 | 12.79 | 1785 | 6 | 59 |
9 | 507.64 | 21 | 13.32 | 1125 | 6 | 66 |
10 | 116.16 | 21 | 13.84 | 582 | 6 | 57 |
11 | -0.00 | 21 | 14.12 | 414 | 6 | 53 |
12 | -0.04 | 200 | 14.00 | 395 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.28 | 36 | 13.97 | 519 | 6 | 9 |
2 | 1952.76 | 20 | 4.50 | 1663 | 9 | 7 |
3 | 1992.80 | 20 | 9.33 | 2814 | 6 | 6 |
4 | 1952.56 | 21 | 11.46 | 2807 | 6 | 17 |
5 | 1866.80 | 20 | 11.86 | 2756 | 6 | 25 |
6 | 1742.80 | 20 | 12.17 | 2564 | 6 | 34 |
7 | 1611.44 | 21 | 12.26 | 2405 | 6 | 41 |
8 | 1187.40 | 20 | 12.71 | 1970 | 6 | 55 |
9 | 629.88 | 21 | 13.19 | 1279 | 6 | 64 |
10 | 204.92 | 21 | 13.70 | 736 | 6 | 64 |
11 | 38.92 | 21 | 14.03 | 469 | 6 | 55 |
12 | -0.20 | 201 | 13.98 | 402 | 6 | 74 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.32 | 35 | 13.97 | 500 | 6 | 8 |
2 | 1958.40 | 20 | 4.51 | 1697 | 6 | 7 |
3 | 2008.48 | 20 | 9.64 | 2819 | 6 | 6 |
4 | 1958.52 | 20 | 11.75 | 2790 | 6 | 19 |
5 | 1870.76 | 20 | 12.03 | 2708 | 6 | 26 |
6 | 1755.68 | 20 | 12.14 | 2614 | 6 | 35 |
7 | 1495.52 | 21 | 12.35 | 2317 | 6 | 44 |
8 | 1080.28 | 20 | 12.83 | 1831 | 6 | 59 |
9 | 555.80 | 21 | 13.26 | 1185 | 6 | 66 |
10 | 146.44 | 21 | 13.81 | 640 | 6 | 60 |
11 | -0.00 | 21 | 14.15 | 416 | 6 | 56 |
12 | -0.04 | 200 | 13.96 | 404 | 6 | 71 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.60 | 35 | 13.97 | 519 | 6 | 8 |
2 | 1956.60 | 20 | 4.49 | 1592 | 8 | 7 |
3 | 2000.24 | 20 | 9.28 | 2807 | 6 | 6 |
4 | 1950.52 | 20 | 11.61 | 2804 | 6 | 16 |
5 | 1866.24 | 21 | 11.90 | 2698 | 6 | 25 |
6 | 1757.88 | 20 | 12.16 | 2602 | 6 | 35 |
7 | 1364.04 | 21 | 12.47 | 2157 | 6 | 50 |
8 | 966.88 | 21 | 12.85 | 1702 | 6 | 59 |
9 | 425.64 | 21 | 13.40 | 1027 | 6 | 66 |
10 | 149.52 | 21 | 13.78 | 651 | 6 | 60 |
11 | -0.04 | 21 | 14.14 | 418 | 6 | 50 |
12 | -0.12 | 200 | 13.96 | 402 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.28 | 35 | 14.04 | 538 | 6 | 8 |
2 | 1954.40 | 20 | 4.50 | 1608 | 6 | 7 |
3 | 2003.08 | 21 | 9.22 | 2815 | 6 | 6 |
4 | 1957.04 | 21 | 11.61 | 2800 | 6 | 15 |
5 | 1868.32 | 21 | 11.95 | 2691 | 6 | 27 |
6 | 1756.56 | 21 | 12.15 | 2574 | 6 | 37 |
7 | 1485.76 | 21 | 12.40 | 2292 | 6 | 47 |
8 | 1062.64 | 21 | 12.78 | 1815 | 6 | 59 |
9 | 481.04 | 21 | 13.38 | 1097 | 6 | 68 |
10 | 96.36 | 21 | 13.92 | 565 | 6 | 58 |
11 | -0.08 | 21 | 14.14 | 426 | 6 | 48 |
12 | -0.12 | 200 | 13.99 | 393 | 6 | 72 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.68 | 35 | 13.91 | 538 | 6 | 9 |
2 | 1957.20 | 20 | 4.45 | 1497 | 9 | 7 |
3 | 2000.20 | 20 | 9.20 | 2857 | 6 | 6 |
4 | 1958.16 | 20 | 11.74 | 2807 | 6 | 18 |
5 | 1881.00 | 21 | 11.85 | 2758 | 6 | 25 |
6 | 1780.12 | 20 | 12.11 | 2653 | 6 | 35 |
7 | 1660.16 | 21 | 12.24 | 2499 | 6 | 40 |
8 | 1211.76 | 20 | 12.71 | 2006 | 6 | 55 |
9 | 532.68 | 21 | 13.27 | 1185 | 6 | 67 |
10 | 123.08 | 21 | 13.84 | 610 | 6 | 56 |
11 | -0.08 | 21 | 14.16 | 418 | 6 | 51 |
12 | -0.12 | 200 | 13.96 | 403 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.12 | 35 | 14.04 | 480 | 6 | 8 |
2 | 1956.36 | 20 | 4.47 | 1550 | 6 | 7 |
3 | 2011.00 | 20 | 9.69 | 2826 | 6 | 6 |
4 | 1973.04 | 20 | 11.73 | 2845 | 6 | 17 |
5 | 1873.40 | 20 | 12.11 | 2692 | 6 | 28 |
6 | 1749.24 | 21 | 12.08 | 2610 | 6 | 36 |
7 | 1623.40 | 20 | 12.30 | 2475 | 6 | 43 |
8 | 1059.92 | 20 | 12.87 | 1807 | 6 | 58 |
9 | 782.72 | 21 | 13.03 | 1488 | 6 | 64 |
10 | 195.40 | 21 | 13.71 | 721 | 6 | 64 |
11 | 33.52 | 21 | 14.08 | 465 | 6 | 55 |
12 | -0.12 | 21 | 14.15 | 431 | 6 | 52 |
13 | -0.16 | 200 | 13.97 | 402 | 6 | 75 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 35 | 13.97 | 538 | 6 | 10 |
2 | 1954.12 | 20 | 4.45 | 1489 | 10 | 7 |
3 | 2004.24 | 21 | 9.39 | 2839 | 6 | 6 |
4 | 1957.00 | 20 | 11.81 | 2805 | 6 | 18 |
5 | 1875.48 | 20 | 12.04 | 2716 | 6 | 27 |
6 | 1758.88 | 20 | 12.26 | 2581 | 6 | 36 |
7 | 1488.28 | 21 | 12.43 | 2294 | 6 | 46 |
8 | 1081.80 | 20 | 12.85 | 1821 | 6 | 59 |
9 | 665.76 | 21 | 13.19 | 1330 | 6 | 65 |
10 | 117.84 | 21 | 13.88 | 589 | 6 | 60 |
11 | 54.04 | 21 | 14.04 | 491 | 6 | 55 |
12 | -0.04 | 201 | 14.01 | 396 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.60 | 35 | 13.97 | 500 | 6 | 9 |
2 | 1955.96 | 20 | 4.45 | 1522 | 9 | 7 |
3 | 2006.24 | 20 | 10.19 | 2792 | 6 | 6 |
4 | 1956.12 | 20 | 11.74 | 2843 | 6 | 18 |
5 | 1856.12 | 20 | 12.03 | 2730 | 6 | 28 |
6 | 1735.64 | 20 | 12.30 | 2547 | 6 | 37 |
7 | 1611.88 | 20 | 12.42 | 2425 | 6 | 43 |
8 | 1034.88 | 20 | 12.91 | 1766 | 6 | 59 |
9 | 749.04 | 21 | 13.08 | 1437 | 6 | 65 |
10 | 166.44 | 21 | 13.77 | 685 | 6 | 64 |
11 | 31.12 | 21 | 14.07 | 467 | 6 | 54 |
12 | -0.04 | 21 | 14.15 | 427 | 6 | 55 |
13 | -0.20 | 200 | 13.97 | 405 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.72 | 35 | 13.97 | 519 | 6 | 8 |
2 | 1958.12 | 20 | 4.46 | 1476 | 6 | 7 |
3 | 2000.44 | 20 | 9.81 | 2874 | 6 | 6 |
4 | 1956.04 | 21 | 11.74 | 2832 | 6 | 21 |
5 | 1875.44 | 21 | 12.07 | 2704 | 6 | 28 |
6 | 1762.88 | 20 | 12.28 | 2595 | 6 | 38 |
7 | 1370.96 | 20 | 12.56 | 2194 | 6 | 50 |
8 | 1099.60 | 20 | 12.80 | 1869 | 6 | 59 |
9 | 526.92 | 21 | 13.32 | 1155 | 6 | 68 |
10 | 114.60 | 21 | 13.89 | 593 | 6 | 59 |
11 | -0.00 | 21 | 14.18 | 422 | 6 | 51 |
12 | -0.08 | 200 | 13.96 | 409 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.28 | 35 | 14.04 | 500 | 6 | 8 |
2 | 1958.36 | 20 | 4.47 | 1490 | 8 | 7 |
3 | 2002.20 | 20 | 10.25 | 2829 | 6 | 6 |
4 | 1947.44 | 21 | 11.80 | 2779 | 6 | 22 |
5 | 1849.88 | 20 | 12.17 | 2692 | 6 | 29 |
6 | 1733.28 | 20 | 12.23 | 2595 | 6 | 38 |
7 | 1601.76 | 20 | 12.38 | 2444 | 6 | 44 |
8 | 915.84 | 20 | 12.97 | 1662 | 6 | 61 |
9 | 643.80 | 20 | 13.24 | 1328 | 6 | 68 |
10 | 199.00 | 21 | 13.72 | 739 | 6 | 67 |
11 | -0.04 | 21 | 14.15 | 422 | 6 | 55 |
12 | -0.20 | 200 | 13.97 | 402 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.72 | 35 | 14.04 | 519 | 6 | 9 |
2 | 1953.72 | 20 | 4.45 | 1501 | 9 | 7 |
3 | 1997.80 | 20 | 10.52 | 2843 | 6 | 6 |
4 | 1948.12 | 21 | 11.84 | 2800 | 6 | 18 |
5 | 1855.16 | 20 | 12.15 | 2706 | 6 | 31 |
6 | 1732.72 | 20 | 12.33 | 2550 | 6 | 39 |
7 | 1343.80 | 21 | 12.58 | 2136 | 6 | 50 |
8 | 1058.40 | 20 | 12.86 | 1821 | 6 | 58 |
9 | 492.92 | 21 | 13.38 | 1095 | 6 | 67 |
10 | 94.76 | 21 | 13.91 | 572 | 6 | 56 |
11 | 0.08 | 21 | 14.16 | 420 | 6 | 59 |
12 | -0.04 | 200 | 13.96 | 406 | 6 | 79 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 35 | 14.04 | 500 | 6 | 8 |
2 | 1954.44 | 20 | 4.49 | 1597 | 6 | 7 |
3 | 2002.84 | 20 | 10.98 | 2857 | 6 | 7 |
4 | 1946.56 | 21 | 11.94 | 2794 | 6 | 24 |
5 | 1832.32 | 20 | 12.22 | 2689 | 6 | 33 |
6 | 1705.64 | 20 | 12.32 | 2535 | 6 | 41 |
7 | 1192.36 | 21 | 12.71 | 1971 | 6 | 55 |
8 | 1065.24 | 20 | 12.90 | 1802 | 6 | 60 |
9 | 338.80 | 21 | 13.56 | 914 | 6 | 70 |
10 | 93.68 | 21 | 13.90 | 585 | 6 | 59 |
11 | -0.08 | 201 | 13.98 | 411 | 6 | 72 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.00 | 35 | 14.04 | 500 | 6 | 8 |
2 | 1958.24 | 20 | 4.45 | 1506 | 8 | 7 |
3 | 2005.36 | 21 | 10.48 | 2839 | 6 | 7 |
4 | 1949.40 | 21 | 11.89 | 2788 | 6 | 20 |
5 | 1853.12 | 20 | 12.20 | 2689 | 6 | 31 |
6 | 1729.92 | 21 | 12.30 | 2523 | 6 | 39 |
7 | 1464.12 | 21 | 12.58 | 2224 | 6 | 46 |
8 | 1020.48 | 20 | 12.95 | 1747 | 6 | 60 |
9 | 440.96 | 21 | 13.44 | 1042 | 6 | 68 |
10 | 82.20 | 21 | 13.97 | 540 | 6 | 56 |
11 | -0.12 | 21 | 14.18 | 418 | 6 | 53 |
12 | -0.20 | 200 | 13.99 | 401 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.44 | 35 | 13.97 | 519 | 6 | 7 |
2 | 1921.00 | 20 | 4.46 | 1518 | 7 | 7 |
3 | 1974.20 | 21 | 10.72 | 2824 | 6 | 6 |
4 | 1916.36 | 20 | 12.01 | 2776 | 6 | 23 |
5 | 1817.24 | 21 | 12.11 | 2685 | 6 | 31 |
6 | 1690.00 | 20 | 12.37 | 2518 | 6 | 40 |
7 | 1406.12 | 20 | 12.59 | 2220 | 6 | 48 |
8 | 986.56 | 20 | 12.94 | 1727 | 6 | 59 |
9 | 560.68 | 21 | 13.35 | 1183 | 6 | 67 |
10 | 116.92 | 21 | 13.89 | 602 | 6 | 61 |
11 | -0.00 | 21 | 14.16 | 422 | 6 | 53 |
12 | -0.20 | 200 | 13.97 | 406 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.20 | 35 | 14.10 | 500 | 6 | 7 |
2 | 1921.36 | 20 | 4.47 | 1527 | 7 | 7 |
3 | 1963.48 | 20 | 10.95 | 2843 | 6 | 7 |
4 | 1909.12 | 21 | 11.93 | 2781 | 6 | 22 |
5 | 1808.44 | 21 | 12.14 | 2664 | 6 | 32 |
6 | 1554.88 | 20 | 12.54 | 2357 | 6 | 43 |
7 | 1287.36 | 21 | 12.65 | 2074 | 6 | 49 |
8 | 881.16 | 21 | 13.03 | 1576 | 6 | 62 |
9 | 456.32 | 21 | 13.44 | 1053 | 6 | 70 |
10 | 71.00 | 21 | 13.98 | 525 | 6 | 57 |
11 | -0.00 | 21 | 14.18 | 418 | 6 | 51 |
12 | -0.04 | 200 | 13.97 | 405 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.88 | 35 | 13.97 | 519 | 6 | 9 |
2 | 1927.24 | 20 | 4.47 | 1534 | 9 | 7 |
3 | 1977.72 | 20 | 11.05 | 2809 | 6 | 8 |
4 | 1925.68 | 21 | 11.95 | 2773 | 6 | 22 |
5 | 1829.12 | 21 | 12.16 | 2679 | 6 | 32 |
6 | 1578.84 | 21 | 12.42 | 2392 | 6 | 42 |
7 | 1454.28 | 21 | 12.54 | 2243 | 6 | 47 |
8 | 878.92 | 21 | 13.05 | 1580 | 6 | 63 |
9 | 449.28 | 21 | 13.43 | 1046 | 6 | 69 |
10 | 68.16 | 21 | 14.03 | 518 | 6 | 57 |
11 | -0.08 | 21 | 14.20 | 416 | 6 | 50 |
12 | -0.20 | 200 | 13.99 | 402 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.80 | 35 | 14.10 | 500 | 6 | 8 |
2 | 1928.40 | 20 | 4.47 | 1543 | 8 | 7 |
3 | 1980.76 | 21 | 10.91 | 2843 | 6 | 8 |
4 | 1919.44 | 20 | 12.13 | 2749 | 6 | 26 |
5 | 1830.00 | 21 | 12.20 | 2655 | 6 | 32 |
6 | 1726.12 | 21 | 12.31 | 2559 | 6 | 38 |
7 | 1324.80 | 20 | 12.65 | 2121 | 6 | 52 |
8 | 915.44 | 20 | 13.04 | 1636 | 6 | 62 |
9 | 488.08 | 21 | 13.45 | 1080 | 6 | 67 |
10 | 90.68 | 21 | 13.95 | 563 | 6 | 60 |
11 | -0.08 | 201 | 14.02 | 396 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.40 | 35 | 14.10 | 500 | 6 | 7 |
2 | 1931.40 | 20 | 4.49 | 1608 | 7 | 7 |
3 | 1988.96 | 20 | 11.26 | 2835 | 6 | 11 |
4 | 1935.04 | 21 | 12.01 | 2781 | 6 | 21 |
5 | 1833.20 | 20 | 12.29 | 2658 | 6 | 32 |
6 | 1704.16 | 21 | 12.36 | 2501 | 6 | 40 |
7 | 1302.36 | 20 | 12.75 | 2078 | 6 | 51 |
8 | 894.12 | 21 | 13.05 | 1591 | 6 | 63 |
9 | 333.88 | 21 | 13.57 | 914 | 6 | 67 |
10 | 82.48 | 21 | 14.00 | 546 | 6 | 57 |
11 | -0.20 | 201 | 14.04 | 396 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.12 | 35 | 14.04 | 519 | 6 | 7 |
2 | 1928.52 | 20 | 4.50 | 1625 | 6 | 7 |
3 | 1978.48 | 21 | 11.19 | 2866 | 6 | 12 |
4 | 1923.32 | 20 | 12.12 | 2776 | 6 | 23 |
5 | 1829.20 | 20 | 12.30 | 2682 | 6 | 34 |
6 | 1706.28 | 21 | 12.31 | 2548 | 6 | 40 |
7 | 1300.88 | 20 | 12.75 | 2081 | 6 | 52 |
8 | 759.88 | 20 | 13.18 | 1439 | 6 | 63 |
9 | 480.76 | 20 | 13.45 | 1093 | 6 | 67 |
10 | 89.76 | 21 | 13.98 | 552 | 6 | 57 |
11 | 4.16 | 21 | 14.15 | 424 | 6 | 53 |
12 | -0.24 | 20 | 14.20 | 422 | 6 | 49 |
13 | -0.20 | 200 | 14.03 | 391 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.44 | 35 | 14.10 | 500 | 6 | 7 |
2 | 1926.00 | 20 | 4.52 | 1627 | 6 | 7 |
3 | 1970.72 | 20 | 11.46 | 2864 | 6 | 10 |
4 | 1919.28 | 20 | 12.15 | 2763 | 6 | 28 |
5 | 1829.60 | 20 | 12.34 | 2665 | 6 | 33 |
6 | 1703.32 | 21 | 12.33 | 2535 | 6 | 39 |
7 | 1433.24 | 20 | 12.68 | 2223 | 6 | 49 |
8 | 881.12 | 21 | 13.08 | 1576 | 6 | 62 |
9 | 467.80 | 21 | 13.46 | 1072 | 6 | 68 |
10 | 78.64 | 21 | 14.02 | 527 | 6 | 57 |
11 | 3.32 | 21 | 14.23 | 411 | 6 | 54 |
12 | -0.16 | 20 | 14.22 | 417 | 6 | 60 |
13 | -0.04 | 200 | 14.04 | 398 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 35 | 14.17 | 519 | 6 | 7 |
2 | 2006.80 | 29 | 4.54 | 1821 | 7 | 7 |
3 | 2039.44 | 20 | 11.76 | 2913 | 6 | 18 |
4 | 1991.32 | 20 | 12.09 | 2879 | 6 | 25 |
5 | 1914.08 | 20 | 12.26 | 2763 | 6 | 33 |
6 | 1815.24 | 20 | 12.36 | 2665 | 6 | 37 |
7 | 1500.64 | 21 | 12.55 | 2313 | 6 | 47 |
8 | 1058.36 | 20 | 12.98 | 1804 | 6 | 59 |
9 | 522.12 | 20 | 13.43 | 1143 | 6 | 67 |
10 | 107.24 | 21 | 13.97 | 576 | 6 | 59 |
11 | 21.84 | 21 | 14.13 | 446 | 6 | 55 |
12 | -0.16 | 20 | 14.21 | 422 | 6 | 49 |
13 | -0.24 | 200 | 14.04 | 399 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.44 | 35 | 14.10 | 519 | 6 | 8 |
2 | 2004.44 | 29 | 4.53 | 1857 | 8 | 7 |
3 | 2047.16 | 20 | 11.80 | 2915 | 6 | 12 |
4 | 2011.64 | 20 | 12.15 | 2874 | 6 | 23 |
5 | 1949.24 | 20 | 12.23 | 2819 | 6 | 30 |
6 | 1862.00 | 20 | 12.35 | 2713 | 6 | 39 |
7 | 1419.00 | 21 | 12.62 | 2217 | 6 | 48 |
8 | 1092.84 | 21 | 12.88 | 1841 | 6 | 59 |
9 | 546.60 | 20 | 13.44 | 1163 | 6 | 69 |
10 | 120.60 | 20 | 13.93 | 600 | 6 | 60 |
11 | 23.52 | 20 | 14.13 | 454 | 6 | 55 |
12 | -0.16 | 21 | 14.23 | 418 | 6 | 58 |
13 | -0.12 | 200 | 14.03 | 398 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.00 | 35 | 14.10 | 519 | 6 | 9 |
2 | 2001.24 | 29 | 4.54 | 1923 | 9 | 7 |
3 | 2027.52 | 20 | 11.84 | 2927 | 6 | 15 |
4 | 1983.12 | 20 | 12.18 | 2850 | 6 | 21 |
5 | 1914.52 | 20 | 12.27 | 2771 | 6 | 30 |
6 | 1825.44 | 20 | 12.38 | 2658 | 6 | 39 |
7 | 1524.40 | 20 | 12.67 | 2324 | 6 | 47 |
8 | 1088.76 | 20 | 12.92 | 1845 | 6 | 60 |
9 | 536.24 | 21 | 13.42 | 1153 | 6 | 70 |
10 | 115.84 | 20 | 13.94 | 595 | 6 | 63 |
11 | 54.44 | 21 | 14.08 | 499 | 6 | 57 |
12 | -0.36 | 201 | 14.04 | 405 | 6 | 72 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 35 | 14.17 | 519 | 6 | 8 |
2 | 2003.48 | 29 | 4.58 | 2086 | 8 | 6 |
3 | 2047.56 | 20 | 11.90 | 2968 | 6 | 16 |
4 | 2007.04 | 20 | 12.16 | 2879 | 6 | 23 |
5 | 1928.16 | 20 | 12.26 | 2807 | 6 | 30 |
6 | 1729.52 | 21 | 12.40 | 2568 | 6 | 39 |
7 | 1530.68 | 20 | 12.68 | 2323 | 6 | 47 |
8 | 1080.24 | 20 | 12.98 | 1831 | 6 | 58 |
9 | 530.88 | 21 | 13.42 | 1153 | 6 | 68 |
10 | 94.60 | 21 | 13.98 | 557 | 6 | 59 |
11 | -0.16 | 20 | 14.27 | 403 | 6 | 51 |
12 | -0.12 | 200 | 14.06 | 394 | 6 | 65 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 35 | 14.10 | 519 | 6 | 8 |
2 | 2008.48 | 29 | 4.64 | 2302 | 6 | 6 |
3 | 2041.16 | 20 | 11.98 | 2932 | 6 | 15 |
4 | 1990.56 | 20 | 12.18 | 2867 | 6 | 25 |
5 | 1909.64 | 20 | 12.28 | 2764 | 6 | 30 |
6 | 1814.00 | 20 | 12.41 | 2651 | 6 | 38 |
7 | 1401.16 | 20 | 12.67 | 2213 | 6 | 51 |
8 | 991.84 | 20 | 13.01 | 1730 | 6 | 60 |
9 | 664.80 | 21 | 13.32 | 1309 | 6 | 67 |
10 | 115.00 | 20 | 13.98 | 583 | 6 | 59 |
11 | 25.32 | 21 | 14.15 | 450 | 6 | 53 |
12 | -0.04 | 21 | 14.20 | 424 | 6 | 57 |
13 | -0.04 | 200 | 14.03 | 405 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.20 | 35 | 14.10 | 519 | 6 | 9 |
2 | 2004.84 | 29 | 5.48 | 2446 | 9 | 6 |
3 | 2030.76 | 21 | 11.86 | 2939 | 6 | 16 |
4 | 1978.28 | 21 | 12.09 | 2832 | 6 | 23 |
5 | 1896.08 | 21 | 12.20 | 2753 | 6 | 32 |
6 | 1595.52 | 21 | 12.50 | 2405 | 6 | 43 |
7 | 1094.32 | 21 | 12.90 | 1860 | 6 | 56 |
8 | 686.84 | 21 | 13.20 | 1386 | 6 | 65 |
9 | 172.72 | 21 | 13.84 | 696 | 6 | 64 |
10 | 32.16 | 21 | 14.13 | 465 | 6 | 54 |
11 | -0.08 | 21 | 14.23 | 422 | 6 | 52 |
12 | -0.12 | 200 | 13.98 | 419 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 35 | 14.10 | 519 | 6 | 9 |
2 | 2006.96 | 29 | 6.57 | 2497 | 9 | 6 |
3 | 2008.60 | 20 | 12.05 | 2855 | 6 | 19 |
4 | 1951.72 | 20 | 12.18 | 2797 | 6 | 27 |
5 | 1861.76 | 20 | 12.24 | 2727 | 6 | 34 |
6 | 1668.80 | 21 | 12.42 | 2480 | 6 | 42 |
7 | 1245.12 | 20 | 12.82 | 2026 | 6 | 55 |
8 | 924.16 | 20 | 13.03 | 1660 | 6 | 63 |
9 | 272.32 | 21 | 13.68 | 826 | 6 | 70 |
10 | 34.64 | 21 | 14.09 | 469 | 6 | 58 |
11 | -0.24 | 201 | 14.03 | 394 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.84 | 35 | 14.04 | 538 | 6 | 8 |
2 | 2012.28 | 28 | 6.99 | 2540 | 8 | 7 |
3 | 1997.16 | 20 | 12.02 | 2857 | 6 | 22 |
4 | 1938.48 | 20 | 12.22 | 2761 | 6 | 27 |
5 | 1849.52 | 20 | 12.31 | 2679 | 6 | 34 |
6 | 1642.56 | 20 | 12.49 | 2461 | 6 | 43 |
7 | 1137.88 | 21 | 12.81 | 1899 | 6 | 57 |
8 | 621.04 | 21 | 13.33 | 1245 | 6 | 67 |
9 | 201.56 | 20 | 13.82 | 706 | 6 | 66 |
10 | 43.68 | 20 | 14.08 | 475 | 6 | 54 |
11 | -0.44 | 200 | 14.02 | 400 | 6 | 81 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.16 | 35 | 14.10 | 557 | 6 | 8 |
2 | 2005.52 | 29 | 7.07 | 2634 | 8 | 8 |
3 | 1980.20 | 20 | 12.08 | 2838 | 6 | 18 |
4 | 1915.20 | 20 | 12.21 | 2768 | 6 | 26 |
5 | 1826.12 | 20 | 12.29 | 2679 | 6 | 36 |
6 | 1629.96 | 20 | 12.49 | 2439 | 6 | 45 |
7 | 1205.48 | 20 | 12.82 | 1965 | 6 | 56 |
8 | 678.88 | 20 | 13.29 | 1328 | 6 | 67 |
9 | 247.48 | 20 | 13.75 | 776 | 6 | 69 |
10 | 29.28 | 21 | 14.17 | 444 | 6 | 56 |
11 | -0.20 | 21 | 14.23 | 409 | 6 | 52 |
12 | -0.24 | 200 | 13.99 | 399 | 6 | 76 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.20 | 35 | 14.10 | 519 | 6 | 9 |
2 | 2003.36 | 29 | 7.43 | 2683 | 9 | 7 |
3 | 1973.84 | 20 | 12.02 | 2843 | 6 | 21 |
4 | 1896.96 | 20 | 12.23 | 2744 | 6 | 27 |
5 | 1701.00 | 20 | 12.42 | 2538 | 6 | 38 |
6 | 1510.68 | 20 | 12.54 | 2333 | 6 | 46 |
7 | 1007.68 | 20 | 12.96 | 1761 | 6 | 59 |
8 | 805.48 | 20 | 13.19 | 1499 | 6 | 66 |
9 | 242.24 | 21 | 13.72 | 785 | 6 | 69 |
10 | 26.60 | 21 | 14.10 | 469 | 6 | 56 |
11 | 13.00 | 20 | 14.13 | 454 | 6 | 59 |
12 | -0.08 | 21 | 14.16 | 431 | 6 | 63 |
13 | -0.24 | 200 | 13.95 | 411 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.96 | 35 | 14.10 | 538 | 6 | 9 |
2 | 2007.64 | 29 | 7.77 | 2714 | 9 | 7 |
3 | 1973.20 | 20 | 12.08 | 2831 | 6 | 22 |
4 | 1903.32 | 20 | 12.24 | 2759 | 6 | 30 |
5 | 1816.12 | 20 | 12.27 | 2684 | 6 | 36 |
6 | 1509.84 | 20 | 12.57 | 2319 | 6 | 47 |
7 | 1197.28 | 21 | 12.78 | 1980 | 6 | 55 |
8 | 557.04 | 21 | 13.34 | 1200 | 6 | 66 |
9 | 126.52 | 20 | 13.95 | 605 | 6 | 60 |
10 | 58.64 | 21 | 14.08 | 506 | 6 | 58 |
11 | 1.08 | 201 | 14.01 | 400 | 6 | 77 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.56 | 35 | 14.04 | 538 | 6 | 9 |
2 | 2002.76 | 29 | 8.15 | 2694 | 9 | 8 |
3 | 1975.84 | 20 | 12.12 | 2809 | 6 | 23 |
4 | 1921.44 | 20 | 12.24 | 2761 | 6 | 29 |
5 | 1841.60 | 20 | 12.29 | 2686 | 6 | 36 |
6 | 1433.12 | 21 | 12.60 | 2213 | 6 | 47 |
7 | 921.88 | 20 | 13.03 | 1658 | 6 | 60 |
8 | 600.00 | 21 | 13.35 | 1243 | 6 | 66 |
9 | 160.92 | 20 | 13.88 | 665 | 6 | 63 |
10 | 14.56 | 20 | 14.17 | 442 | 6 | 57 |
11 | -0.12 | 201 | 13.98 | 408 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.20 | 35 | 14.04 | 519 | 6 | 8 |
2 | 2006.20 | 29 | 8.31 | 2734 | 8 | 10 |
3 | 1964.36 | 20 | 12.12 | 2814 | 6 | 21 |
4 | 1884.92 | 20 | 12.20 | 2737 | 6 | 32 |
5 | 1788.44 | 20 | 12.36 | 2624 | 6 | 37 |
6 | 1587.76 | 20 | 12.51 | 2405 | 6 | 45 |
7 | 1064.76 | 20 | 12.89 | 1836 | 6 | 58 |
8 | 735.88 | 20 | 13.20 | 1432 | 6 | 67 |
9 | 194.52 | 20 | 13.80 | 723 | 6 | 65 |
10 | 41.60 | 20 | 14.16 | 468 | 6 | 54 |
11 | -0.20 | 201 | 14.00 | 404 | 6 | 75 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.84 | 35 | 14.04 | 538 | 6 | 10 |
2 | 2000.60 | 29 | 8.64 | 2721 | 10 | 7 |
3 | 1965.56 | 20 | 12.07 | 2848 | 6 | 22 |
4 | 1897.96 | 21 | 12.16 | 2758 | 6 | 28 |
5 | 1803.96 | 21 | 12.28 | 2629 | 6 | 38 |
6 | 1384.88 | 20 | 12.63 | 2196 | 6 | 50 |
7 | 879.72 | 21 | 13.07 | 1587 | 6 | 61 |
8 | 551.72 | 21 | 13.37 | 1194 | 6 | 68 |
9 | 61.64 | 21 | 14.04 | 514 | 6 | 58 |
10 | -0.12 | 20 | 14.22 | 420 | 6 | 54 |
11 | -0.16 | 200 | 13.98 | 408 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.32 | 35 | 14.04 | 538 | 6 | 8 |
2 | 2003.36 | 29 | 8.81 | 2714 | 8 | 10 |
3 | 1957.44 | 20 | 12.08 | 2833 | 6 | 22 |
4 | 1883.44 | 20 | 12.22 | 2735 | 6 | 30 |
5 | 1790.36 | 20 | 12.36 | 2612 | 6 | 38 |
6 | 1491.40 | 20 | 12.57 | 2309 | 6 | 48 |
7 | 1064.08 | 20 | 12.97 | 1804 | 6 | 57 |
8 | 543.32 | 21 | 13.39 | 1161 | 6 | 66 |
9 | 106.88 | 20 | 13.98 | 576 | 6 | 61 |
10 | 50.32 | 21 | 14.10 | 497 | 6 | 59 |
11 | -0.12 | 21 | 14.24 | 422 | 6 | 55 |
12 | -0.04 | 200 | 13.98 | 405 | 6 | 74 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.52 | 35 | 14.10 | 519 | 6 | 8 |
2 | 2003.56 | 29 | 8.89 | 2738 | 8 | 10 |
3 | 1955.20 | 20 | 12.11 | 2812 | 6 | 22 |
4 | 1878.48 | 20 | 12.22 | 2718 | 6 | 33 |
5 | 1784.00 | 20 | 12.38 | 2598 | 6 | 37 |
6 | 1475.92 | 20 | 12.59 | 2285 | 6 | 48 |
7 | 1152.28 | 21 | 12.80 | 1899 | 6 | 59 |
8 | 815.76 | 20 | 13.16 | 1506 | 6 | 67 |
9 | 144.04 | 20 | 13.87 | 650 | 6 | 62 |
10 | 27.76 | 21 | 14.14 | 463 | 6 | 54 |
11 | -0.16 | 21 | 14.18 | 437 | 6 | 66 |
12 | -0.20 | 200 | 13.95 | 409 | 6 | 67 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.32 | 35 | 14.10 | 519 | 6 | 10 |
2 | 2007.16 | 29 | 9.00 | 2771 | 10 | 8 |
3 | 1958.32 | 20 | 12.07 | 2850 | 6 | 22 |
4 | 1884.84 | 20 | 12.23 | 2737 | 6 | 32 |
5 | 1795.80 | 20 | 12.34 | 2636 | 6 | 39 |
6 | 1373.20 | 20 | 12.68 | 2160 | 6 | 51 |
7 | 1066.72 | 20 | 12.97 | 1799 | 6 | 60 |
8 | 639.20 | 21 | 13.27 | 1305 | 6 | 68 |
9 | 178.00 | 20 | 13.86 | 701 | 6 | 65 |
10 | 12.84 | 20 | 14.14 | 456 | 6 | 54 |
11 | -0.16 | 21 | 14.18 | 431 | 6 | 56 |
12 | -0.24 | 200 | 13.92 | 413 | 6 | 75 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 35 | 14.10 | 538 | 6 | 8 |
2 | 2003.64 | 29 | 9.28 | 2789 | 6 | 9 |
3 | 1967.24 | 20 | 12.10 | 2833 | 6 | 24 |
4 | 1892.76 | 20 | 12.23 | 2761 | 6 | 31 |
5 | 1697.08 | 20 | 12.45 | 2526 | 6 | 39 |
6 | 1289.52 | 20 | 12.81 | 2064 | 6 | 52 |
7 | 975.44 | 20 | 12.99 | 1728 | 6 | 62 |
8 | 653.96 | 20 | 13.33 | 1321 | 6 | 66 |
9 | 202.80 | 21 | 13.78 | 751 | 6 | 66 |
10 | -0.20 | 201 | 13.96 | 408 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.60 | 35 | 14.10 | 519 | 6 | 9 |
2 | 2004.24 | 28 | 9.45 | 2741 | 9 | 8 |
3 | 1950.64 | 20 | 12.17 | 2778 | 6 | 23 |
4 | 1865.08 | 20 | 12.30 | 2689 | 6 | 33 |
5 | 1668.92 | 20 | 12.43 | 2497 | 6 | 39 |
6 | 1468.80 | 20 | 12.65 | 2251 | 6 | 48 |
7 | 1038.36 | 20 | 12.99 | 1780 | 6 | 60 |
8 | 578.12 | 20 | 13.35 | 1232 | 6 | 68 |
9 | 142.60 | 21 | 13.87 | 659 | 6 | 62 |
10 | -0.16 | 21 | 14.21 | 429 | 6 | 67 |
11 | -0.12 | 200 | 13.95 | 409 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.68 | 35 | 14.10 | 519 | 6 | 8 |
2 | 2001.92 | 28 | 9.45 | 2765 | 8 | 10 |
3 | 1946.64 | 20 | 12.18 | 2783 | 6 | 22 |
4 | 1861.64 | 20 | 12.27 | 2701 | 6 | 32 |
5 | 1763.84 | 20 | 12.43 | 2583 | 6 | 39 |
6 | 1561.04 | 20 | 12.59 | 2372 | 6 | 45 |
7 | 1116.40 | 20 | 12.88 | 1872 | 6 | 57 |
8 | 655.24 | 21 | 13.29 | 1279 | 6 | 67 |
9 | 106.56 | 21 | 13.95 | 576 | 6 | 61 |
10 | -0.04 | 20 | 14.24 | 420 | 6 | 58 |
11 | -0.08 | 200 | 13.97 | 401 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.32 | 35 | 14.04 | 519 | 6 | 10 |
2 | 2000.48 | 29 | 9.55 | 2736 | 10 | 8 |
3 | 1953.60 | 20 | 12.13 | 2826 | 6 | 23 |
4 | 1887.20 | 21 | 12.18 | 2719 | 6 | 32 |
5 | 1791.04 | 21 | 12.30 | 2614 | 6 | 39 |
6 | 1456.72 | 20 | 12.62 | 2273 | 6 | 49 |
7 | 828.00 | 21 | 13.15 | 1518 | 6 | 63 |
8 | 294.76 | 21 | 13.67 | 856 | 6 | 69 |
9 | 87.20 | 21 | 14.00 | 561 | 6 | 63 |
10 | 16.88 | 21 | 14.17 | 454 | 6 | 56 |
11 | -0.16 | 201 | 13.96 | 407 | 6 | 77 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.56 | 35 | 14.04 | 557 | 6 | 10 |
2 | 2007.52 | 28 | 9.48 | 2798 | 6 | 8 |
3 | 1964.24 | 20 | 12.13 | 2833 | 6 | 25 |
4 | 1892.00 | 20 | 12.27 | 2749 | 6 | 31 |
5 | 1607.92 | 20 | 12.52 | 2449 | 6 | 42 |
6 | 1510.88 | 20 | 12.60 | 2336 | 6 | 46 |
7 | 1170.24 | 21 | 12.80 | 1944 | 6 | 58 |
8 | 505.92 | 21 | 13.44 | 1091 | 6 | 67 |
9 | 89.08 | 20 | 13.99 | 552 | 6 | 61 |
10 | -0.04 | 21 | 14.21 | 418 | 6 | 59 |
11 | -0.00 | 200 | 13.94 | 399 | 6 | 76 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.92 | 35 | 13.97 | 557 | 6 | 11 |
2 | 2003.40 | 28 | 9.66 | 2772 | 6 | 9 |
3 | 1952.80 | 20 | 12.13 | 2824 | 6 | 21 |
4 | 1878.52 | 20 | 12.27 | 2720 | 6 | 32 |
5 | 1788.88 | 20 | 12.39 | 2614 | 6 | 38 |
6 | 1368.76 | 20 | 12.70 | 2172 | 6 | 51 |
7 | 957.96 | 21 | 13.01 | 1687 | 6 | 63 |
8 | 636.04 | 20 | 13.33 | 1312 | 6 | 67 |
9 | 171.32 | 20 | 13.83 | 701 | 6 | 65 |
10 | 13.32 | 20 | 14.16 | 458 | 6 | 60 |
11 | -0.28 | 201 | 13.89 | 432 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.48 | 35 | 13.97 | 557 | 6 | 8 |
2 | 2005.00 | 28 | 9.57 | 2793 | 6 | 10 |
3 | 1952.76 | 20 | 12.19 | 2795 | 6 | 25 |
4 | 1877.24 | 20 | 12.36 | 2718 | 6 | 32 |
5 | 1788.44 | 20 | 12.41 | 2626 | 6 | 39 |
6 | 1369.76 | 20 | 12.72 | 2175 | 6 | 50 |
7 | 848.28 | 20 | 13.16 | 1566 | 6 | 62 |
8 | 526.40 | 20 | 13.42 | 1167 | 6 | 67 |
9 | 99.60 | 21 | 13.99 | 574 | 6 | 59 |
10 | -0.16 | 21 | 14.25 | 416 | 6 | 59 |
11 | -0.12 | 200 | 13.91 | 424 | 6 | 70 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 35 | 14.10 | 538 | 6 | 11 |
2 | 2005.56 | 28 | 9.54 | 2816 | 6 | 10 |
3 | 1958.60 | 20 | 12.14 | 2785 | 6 | 22 |
4 | 1876.60 | 21 | 12.21 | 2715 | 6 | 31 |
5 | 1671.84 | 21 | 12.45 | 2486 | 6 | 41 |
6 | 1251.48 | 20 | 12.81 | 2033 | 6 | 54 |
7 | 940.56 | 20 | 13.07 | 1672 | 6 | 62 |
8 | 389.00 | 21 | 13.57 | 965 | 6 | 67 |
9 | 76.52 | 21 | 14.01 | 540 | 6 | 59 |
10 | -0.12 | 21 | 14.22 | 420 | 6 | 58 |
11 | -0.08 | 200 | 13.91 | 413 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.88 | 35 | 14.04 | 538 | 6 | 8 |
2 | 2004.08 | 28 | 9.57 | 2810 | 8 | 10 |
3 | 1961.00 | 20 | 12.18 | 2800 | 6 | 24 |
4 | 1886.28 | 20 | 12.28 | 2732 | 6 | 34 |
5 | 1787.64 | 20 | 12.33 | 2655 | 6 | 40 |
6 | 1370.32 | 20 | 12.76 | 2167 | 6 | 49 |
7 | 846.64 | 20 | 13.16 | 1552 | 6 | 62 |
8 | 526.68 | 20 | 13.42 | 1163 | 6 | 68 |
9 | 93.56 | 20 | 13.98 | 571 | 6 | 58 |
10 | -0.04 | 201 | 13.94 | 425 | 6 | 72 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.88 | 35 | 14.04 | 538 | 6 | 10 |
2 | 2007.44 | 28 | 9.67 | 2802 | 10 | 9 |
3 | 1962.96 | 20 | 12.12 | 2826 | 6 | 22 |
4 | 1880.48 | 20 | 12.27 | 2749 | 6 | 32 |
5 | 1682.88 | 20 | 12.47 | 2521 | 6 | 42 |
6 | 1483.28 | 20 | 12.62 | 2302 | 6 | 48 |
7 | 839.96 | 20 | 13.18 | 1526 | 6 | 63 |
8 | 532.52 | 21 | 13.35 | 1189 | 6 | 67 |
9 | 85.64 | 20 | 13.97 | 564 | 6 | 59 |
10 | 4.08 | 20 | 14.20 | 444 | 6 | 56 |
11 | -0.00 | 21 | 14.18 | 440 | 6 | 69 |
12 | -0.04 | 200 | 13.92 | 408 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.92 | 35 | 14.04 | 538 | 6 | 9 |
2 | 2006.08 | 28 | 9.78 | 2777 | 9 | 13 |
3 | 1955.76 | 20 | 12.15 | 2824 | 6 | 24 |
4 | 1881.64 | 20 | 12.31 | 2720 | 6 | 33 |
5 | 1791.20 | 20 | 12.41 | 2629 | 6 | 39 |
6 | 1367.32 | 20 | 12.75 | 2167 | 6 | 49 |
7 | 841.68 | 20 | 13.17 | 1552 | 6 | 62 |
8 | 530.36 | 20 | 13.41 | 1177 | 6 | 68 |
9 | 94.84 | 20 | 13.98 | 571 | 6 | 60 |
10 | -0.28 | 201 | 13.96 | 408 | 6 | 77 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 35 | 14.04 | 557 | 6 | 11 |
2 | 2005.52 | 28 | 9.71 | 2793 | 6 | 11 |
3 | 1954.24 | 20 | 12.12 | 2804 | 6 | 23 |
4 | 1878.24 | 20 | 12.27 | 2747 | 6 | 33 |
5 | 1786.76 | 20 | 12.40 | 2636 | 6 | 39 |
6 | 1280.76 | 20 | 12.84 | 2045 | 6 | 54 |
7 | 965.72 | 20 | 13.04 | 1703 | 6 | 61 |
8 | 430.80 | 21 | 13.54 | 1023 | 6 | 67 |
9 | 55.80 | 21 | 14.08 | 508 | 6 | 57 |
10 | 9.00 | 20 | 14.20 | 449 | 6 | 57 |
11 | -0.08 | 21 | 14.18 | 440 | 6 | 65 |
12 | -0.16 | 200 | 13.91 | 416 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.64 | 35 | 14.17 | 519 | 6 | 8 |
2 | 2004.44 | 28 | 9.73 | 2796 | 8 | 9 |
3 | 1945.28 | 20 | 12.11 | 2826 | 6 | 24 |
4 | 1865.68 | 20 | 12.26 | 2751 | 6 | 32 |
5 | 1779.24 | 21 | 12.37 | 2597 | 6 | 39 |
6 | 1366.84 | 20 | 12.72 | 2177 | 6 | 51 |
7 | 959.44 | 21 | 13.04 | 1687 | 6 | 60 |
8 | 332.64 | 21 | 13.67 | 886 | 6 | 67 |
9 | 57.16 | 21 | 14.08 | 508 | 6 | 59 |
10 | -0.04 | 21 | 14.25 | 420 | 6 | 57 |
11 | -0.16 | 200 | 13.94 | 405 | 6 | 74 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.68 | 35 | 14.10 | 538 | 6 | 10 |
2 | 2003.52 | 28 | 9.80 | 2777 | 10 | 11 |
3 | 1958.28 | 20 | 12.11 | 2840 | 6 | 26 |
4 | 1876.24 | 20 | 12.24 | 2761 | 6 | 33 |
5 | 1583.12 | 20 | 12.58 | 2384 | 6 | 44 |
6 | 1488.88 | 20 | 12.63 | 2304 | 6 | 48 |
7 | 1061.60 | 20 | 12.99 | 1797 | 6 | 58 |
8 | 509.28 | 20 | 13.52 | 1097 | 6 | 70 |
9 | 81.56 | 21 | 14.02 | 538 | 6 | 60 |
10 | 37.68 | 20 | 14.13 | 480 | 6 | 60 |
11 | -0.12 | 201 | 13.97 | 401 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.92 | 35 | 14.04 | 538 | 6 | 10 |
2 | 2004.08 | 28 | 9.84 | 2784 | 10 | 11 |
3 | 1964.52 | 20 | 12.10 | 2843 | 6 | 25 |
4 | 1888.56 | 20 | 12.31 | 2754 | 6 | 32 |
5 | 1592.32 | 20 | 12.60 | 2405 | 6 | 43 |
6 | 1493.88 | 20 | 12.64 | 2300 | 6 | 48 |
7 | 848.96 | 20 | 13.13 | 1564 | 6 | 64 |
8 | 439.84 | 20 | 13.55 | 1042 | 6 | 67 |
9 | 113.28 | 21 | 13.99 | 595 | 6 | 62 |
10 | -0.12 | 21 | 14.25 | 418 | 6 | 58 |
11 | -0.12 | 200 | 13.90 | 412 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.08 | 35 | 13.97 | 557 | 6 | 8 |
2 | 2001.28 | 29 | 9.81 | 2791 | 8 | 11 |
3 | 1949.12 | 21 | 12.07 | 2796 | 6 | 23 |
4 | 1873.72 | 21 | 12.21 | 2732 | 6 | 33 |
5 | 1780.36 | 21 | 12.35 | 2621 | 6 | 38 |
6 | 1349.64 | 21 | 12.71 | 2159 | 6 | 51 |
7 | 894.00 | 21 | 13.05 | 1632 | 6 | 63 |
8 | 245.48 | 21 | 13.79 | 788 | 6 | 68 |
9 | 66.44 | 21 | 14.06 | 538 | 6 | 62 |
10 | -0.20 | 21 | 14.25 | 426 | 6 | 54 |
11 | -0.24 | 200 | 13.86 | 437 | 6 | 68 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.56 | 35 | 14.17 | 519 | 6 | 7 |
2 | 2007.88 | 28 | 9.82 | 2797 | 7 | 12 |
3 | 1959.68 | 20 | 12.10 | 2845 | 6 | 26 |
4 | 1881.88 | 20 | 12.30 | 2730 | 6 | 34 |
5 | 1789.52 | 20 | 12.34 | 2670 | 6 | 40 |
6 | 1285.08 | 21 | 12.81 | 2063 | 6 | 52 |
7 | 857.40 | 20 | 13.14 | 1574 | 6 | 64 |
8 | 327.28 | 21 | 13.67 | 894 | 6 | 70 |
9 | 64.00 | 20 | 14.11 | 528 | 6 | 60 |
10 | -0.32 | 21 | 14.27 | 420 | 6 | 61 |
11 | -0.20 | 200 | 13.90 | 425 | 6 | 59 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.88 | 35 | 14.10 | 538 | 6 | 9 |
2 | 2006.20 | 28 | 9.93 | 2772 | 9 | 10 |
3 | 1953.12 | 20 | 12.14 | 2807 | 6 | 22 |
4 | 1873.84 | 20 | 12.28 | 2747 | 6 | 34 |
5 | 1781.20 | 20 | 12.45 | 2605 | 6 | 41 |
6 | 1376.20 | 20 | 12.74 | 2184 | 6 | 50 |
7 | 959.68 | 20 | 13.08 | 1674 | 6 | 63 |
8 | 428.04 | 20 | 13.58 | 1021 | 6 | 66 |
9 | 116.52 | 20 | 13.99 | 607 | 6 | 64 |
10 | 25.24 | 20 | 14.21 | 456 | 6 | 56 |
11 | -0.16 | 21 | 14.27 | 418 | 6 | 55 |
12 | -0.12 | 200 | 13.91 | 425 | 6 | 76 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.88 | 35 | 14.17 | 519 | 6 | 7 |
2 | 2004.68 | 28 | 9.87 | 2782 | 7 | 15 |
3 | 1956.00 | 20 | 12.18 | 2814 | 6 | 26 |
4 | 1886.44 | 20 | 12.34 | 2737 | 6 | 33 |
5 | 1797.28 | 20 | 12.46 | 2627 | 6 | 38 |
6 | 1489.36 | 20 | 12.70 | 2283 | 6 | 48 |
7 | 1053.64 | 21 | 12.95 | 1800 | 6 | 60 |
8 | 407.52 | 20 | 13.61 | 994 | 6 | 72 |
9 | 85.24 | 20 | 14.03 | 559 | 6 | 64 |
10 | 39.48 | 21 | 14.13 | 495 | 6 | 59 |
11 | -0.36 | 201 | 13.94 | 427 | 6 | 72 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.36 | 35 | 14.17 | 500 | 6 | 7 |
2 | 2005.32 | 28 | 9.86 | 2802 | 7 | 15 |
3 | 1956.96 | 20 | 12.07 | 2872 | 6 | 24 |
4 | 1884.24 | 20 | 12.30 | 2759 | 6 | 34 |
5 | 1790.72 | 20 | 12.39 | 2646 | 6 | 40 |
6 | 1372.52 | 20 | 12.74 | 2199 | 6 | 53 |
7 | 1165.40 | 21 | 12.87 | 1937 | 6 | 58 |
8 | 394.84 | 21 | 13.58 | 982 | 6 | 70 |
9 | 80.64 | 20 | 14.07 | 550 | 6 | 58 |
10 | 18.08 | 20 | 14.21 | 465 | 6 | 59 |
11 | -0.00 | 20 | 14.25 | 442 | 6 | 57 |
12 | -0.08 | 200 | 13.91 | 427 | 6 | 75 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.12 | 34 | 14.17 | 538 | 6 | 7 |
2 | 2001.20 | 28 | 9.83 | 2802 | 6 | 10 |
3 | 1951.12 | 20 | 12.08 | 2855 | 6 | 22 |
4 | 1871.96 | 20 | 12.29 | 2754 | 6 | 36 |
5 | 1671.24 | 20 | 12.57 | 2511 | 6 | 43 |
6 | 1462.88 | 20 | 12.65 | 2297 | 6 | 49 |
7 | 831.48 | 21 | 13.15 | 1546 | 6 | 64 |
8 | 510.60 | 21 | 13.45 | 1132 | 6 | 71 |
9 | 83.00 | 20 | 14.05 | 547 | 6 | 61 |
10 | 15.44 | 21 | 14.21 | 448 | 6 | 56 |
11 | -0.24 | 201 | 13.90 | 432 | 6 | 69 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 34 | 14.10 | 557 | 6 | 7 |
2 | 2008.64 | 28 | 10.57 | 2832 | 7 | 10 |
3 | 1957.76 | 20 | 12.05 | 2860 | 6 | 24 |
4 | 1878.88 | 20 | 12.33 | 2737 | 6 | 32 |
5 | 1586.44 | 20 | 12.63 | 2403 | 6 | 45 |
6 | 1391.32 | 20 | 12.76 | 2184 | 6 | 52 |
7 | 851.36 | 21 | 13.15 | 1559 | 6 | 66 |
8 | 325.52 | 20 | 13.68 | 908 | 6 | 71 |
9 | 58.36 | 20 | 14.11 | 523 | 6 | 58 |
10 | -0.16 | 21 | 14.29 | 442 | 6 | 59 |
11 | -0.08 | 200 | 13.90 | 430 | 6 | 58 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 34 | 14.17 | 538 | 6 | 8 |
2 | 2003.40 | 70 | 10.49 | 2822 | 8 | 20 |
3 | 1786.08 | 24 | 12.19 | 2653 | 6 | 39 |
4 | 1321.36 | 24 | 12.63 | 2140 | 6 | 52 |
5 | 867.20 | 24 | 13.09 | 1593 | 6 | 63 |
6 | 176.92 | 24 | 13.85 | 707 | 6 | 66 |
7 | 34.64 | 25 | 14.17 | 476 | 6 | 57 |
8 | -0.08 | 24 | 14.24 | 449 | 6 | 53 |
9 | -0.16 | 297 | 13.74 | 441 | 6 | 159 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.24 | 34 | 14.17 | 538 | 6 | 7 |
2 | 2003.24 | 70 | 10.44 | 2843 | 7 | 19 |
3 | 1789.36 | 24 | 12.19 | 2661 | 6 | 39 |
4 | 1323.72 | 24 | 12.65 | 2132 | 6 | 52 |
5 | 638.88 | 24 | 13.27 | 1320 | 6 | 65 |
6 | 194.28 | 24 | 13.82 | 755 | 6 | 69 |
7 | 37.84 | 24 | 14.18 | 474 | 6 | 60 |
8 | 0.52 | 324 | 13.75 | 441 | 6 | 153 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.28 | 34 | 14.23 | 538 | 6 | 7 |
2 | 2005.84 | 70 | 10.39 | 2865 | 6 | 21 |
3 | 1785.76 | 24 | 12.27 | 2626 | 6 | 38 |
4 | 1333.28 | 24 | 12.67 | 2136 | 6 | 51 |
5 | 682.24 | 25 | 13.27 | 1370 | 6 | 64 |
6 | 219.32 | 24 | 13.80 | 782 | 6 | 66 |
7 | 38.80 | 25 | 14.14 | 497 | 6 | 60 |
8 | -0.20 | 24 | 14.24 | 453 | 6 | 53 |
9 | -0.24 | 300 | 13.72 | 442 | 6 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 34 | 14.23 | 519 | 6 | 7 |
2 | 2001.80 | 70 | 10.43 | 2840 | 6 | 18 |
3 | 1793.56 | 24 | 12.23 | 2643 | 6 | 38 |
4 | 1335.44 | 24 | 12.69 | 2126 | 6 | 50 |
5 | 875.80 | 24 | 13.08 | 1605 | 6 | 63 |
6 | 198.84 | 24 | 13.85 | 738 | 6 | 67 |
7 | 39.24 | 25 | 14.21 | 470 | 6 | 56 |
8 | -0.16 | 24 | 14.27 | 424 | 6 | 56 |
9 | -0.24 | 300 | 13.76 | 438 | 6 | 177 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.08 | 34 | 14.23 | 519 | 6 | 7 |
2 | 2006.76 | 70 | 10.38 | 2772 | 7 | 18 |
3 | 1787.32 | 25 | 12.33 | 2616 | 6 | 37 |
4 | 1130.76 | 25 | 12.89 | 1876 | 6 | 54 |
5 | 693.12 | 24 | 13.34 | 1339 | 6 | 67 |
6 | 117.92 | 24 | 14.00 | 628 | 6 | 62 |
7 | 53.84 | 25 | 14.16 | 532 | 6 | 56 |
8 | -0.20 | 24 | 14.35 | 420 | 6 | 59 |
9 | -0.20 | 292 | 13.84 | 428 | 6 | 141 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 34 | 14.23 | 538 | 6 | 7 |
2 | 2003.24 | 70 | 10.38 | 2824 | 6 | 19 |
3 | 1786.76 | 24 | 12.26 | 2620 | 6 | 38 |
4 | 1344.48 | 24 | 12.69 | 2145 | 6 | 53 |
5 | 658.16 | 24 | 13.35 | 1311 | 6 | 65 |
6 | 205.32 | 24 | 13.91 | 713 | 6 | 66 |
7 | 41.00 | 24 | 14.19 | 484 | 6 | 58 |
8 | -0.24 | 24 | 14.25 | 463 | 6 | 53 |
9 | -0.24 | 300 | 13.77 | 437 | 6 | 177 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.44 | 34 | 14.23 | 538 | 6 | 8 |
2 | 2008.32 | 70 | 10.16 | 2857 | 8 | 16 |
3 | 1815.48 | 24 | 12.25 | 2680 | 6 | 35 |
4 | 1373.76 | 24 | 12.67 | 2207 | 6 | 50 |
5 | 711.04 | 25 | 13.25 | 1414 | 6 | 67 |
6 | 135.60 | 24 | 13.99 | 655 | 6 | 63 |
7 | 30.92 | 24 | 14.24 | 489 | 6 | 54 |
8 | -0.08 | 24 | 14.29 | 451 | 6 | 54 |
9 | -0.20 | 297 | 13.83 | 421 | 6 | 188 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.00 | 34 | 14.23 | 538 | 6 | 7 |
2 | 2002.64 | 70 | 10.18 | 2822 | 6 | 14 |
3 | 1800.36 | 24 | 12.33 | 2641 | 6 | 37 |
4 | 1361.64 | 24 | 12.72 | 2170 | 6 | 51 |
5 | 699.24 | 25 | 13.30 | 1366 | 6 | 66 |
6 | 240.04 | 25 | 13.83 | 799 | 6 | 68 |
7 | 19.56 | 25 | 14.19 | 495 | 6 | 57 |
8 | -0.12 | 25 | 14.29 | 447 | 6 | 54 |
9 | -0.12 | 297 | 13.77 | 439 | 6 | 183 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.44 | 34 | 14.23 | 519 | 6 | 7 |
2 | 2006.96 | 70 | 10.19 | 2790 | 7 | 14 |
3 | 1794.68 | 24 | 12.29 | 2657 | 6 | 37 |
4 | 1351.48 | 24 | 12.76 | 2159 | 6 | 50 |
5 | 694.56 | 25 | 13.31 | 1399 | 6 | 66 |
6 | 241.64 | 24 | 13.83 | 822 | 6 | 66 |
7 | 46.00 | 25 | 14.22 | 505 | 6 | 56 |
8 | -0.00 | 24 | 14.30 | 449 | 6 | 54 |
9 | -0.16 | 297 | 13.77 | 442 | 6 | 136 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.68 | 34 | 14.29 | 519 | 6 | 7 |
2 | 2002.48 | 70 | 10.07 | 2763 | 7 | 14 |
3 | 1800.00 | 24 | 12.33 | 2661 | 6 | 36 |
4 | 1139.32 | 24 | 12.90 | 1920 | 6 | 55 |
5 | 710.72 | 24 | 13.37 | 1391 | 6 | 67 |
6 | 238.92 | 25 | 13.86 | 793 | 6 | 67 |
7 | 38.88 | 24 | 14.21 | 511 | 6 | 57 |
8 | -0.24 | 24 | 14.27 | 457 | 6 | 61 |
9 | -0.28 | 297 | 13.76 | 439 | 6 | 139 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.28 | 34 | 14.23 | 538 | 6 | 7 |
2 | 2005.04 | 70 | 10.19 | 2790 | 7 | 14 |
3 | 1815.08 | 24 | 12.37 | 2653 | 6 | 37 |
4 | 1360.92 | 24 | 12.81 | 2147 | 6 | 51 |
5 | 678.60 | 25 | 13.41 | 1326 | 6 | 66 |
6 | 214.20 | 24 | 13.93 | 718 | 6 | 66 |
7 | 41.16 | 25 | 14.24 | 501 | 6 | 55 |
8 | -0.20 | 24 | 14.30 | 459 | 6 | 57 |
9 | -0.16 | 297 | 13.80 | 438 | 6 | 143 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.04 | 34 | 14.23 | 538 | 6 | 6 |
2 | 2006.64 | 70 | 10.24 | 2772 | 6 | 15 |
3 | 1789.64 | 25 | 12.35 | 2647 | 6 | 38 |
4 | 1316.76 | 24 | 12.82 | 2118 | 6 | 53 |
5 | 648.08 | 25 | 13.43 | 1289 | 6 | 66 |
6 | 187.08 | 25 | 13.97 | 701 | 6 | 66 |
7 | 38.32 | 25 | 14.22 | 513 | 6 | 55 |
8 | -0.16 | 321 | 13.83 | 433 | 6 | 183 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.32 | 34 | 14.29 | 519 | 6 | 6 |
2 | 2006.00 | 70 | 10.28 | 2826 | 6 | 15 |
3 | 1608.24 | 24 | 12.57 | 2434 | 6 | 43 |
4 | 1395.08 | 24 | 12.78 | 2188 | 6 | 53 |
5 | 690.00 | 24 | 13.41 | 1341 | 6 | 68 |
6 | 237.72 | 24 | 13.90 | 807 | 6 | 66 |
7 | 45.36 | 25 | 14.23 | 507 | 6 | 58 |
8 | -0.04 | 24 | 14.36 | 409 | 6 | 56 |
9 | -0.08 | 297 | 13.80 | 438 | 6 | 165 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 34 | 14.23 | 538 | 6 | 7 |
2 | 2006.92 | 70 | 10.33 | 2868 | 6 | 16 |
3 | 1790.36 | 24 | 12.43 | 2632 | 6 | 39 |
4 | 1327.72 | 24 | 12.88 | 2114 | 6 | 52 |
5 | 652.08 | 25 | 13.45 | 1332 | 6 | 66 |
6 | 191.32 | 24 | 13.98 | 720 | 6 | 67 |
7 | 1.20 | 348 | 13.84 | 419 | 6 | 223 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.36 | 34 | 14.29 | 519 | 6 | 7 |
2 | 2001.76 | 71 | 10.44 | 2826 | 7 | 15 |
3 | 1585.32 | 25 | 12.64 | 2407 | 6 | 43 |
4 | 1153.36 | 25 | 13.02 | 1934 | 6 | 57 |
5 | 679.96 | 25 | 13.44 | 1365 | 6 | 69 |
6 | 106.88 | 25 | 14.15 | 584 | 6 | 61 |
7 | 3.92 | 25 | 14.37 | 407 | 6 | 51 |
8 | -0.12 | 24 | 14.22 | 461 | 6 | 53 |
9 | -0.16 | 290 | 13.83 | 425 | 6 | 175 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.92 | 34 | 14.29 | 500 | 6 | 6 |
2 | 2006.00 | 71 | 10.59 | 2830 | 6 | 18 |
3 | 1599.32 | 25 | 12.61 | 2432 | 6 | 43 |
4 | 1159.64 | 25 | 13.00 | 1959 | 6 | 57 |
5 | 491.36 | 25 | 13.62 | 1141 | 6 | 65 |
6 | 120.72 | 25 | 14.10 | 636 | 6 | 62 |
7 | 30.36 | 25 | 14.34 | 443 | 6 | 56 |
8 | -0.08 | 24 | 14.33 | 440 | 6 | 60 |
9 | -0.12 | 287 | 13.88 | 420 | 6 | 159 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.80 | 34 | 14.36 | 480 | 6 | 6 |
2 | 2006.84 | 71 | 10.71 | 2787 | 6 | 20 |
3 | 1791.28 | 25 | 12.51 | 2626 | 6 | 39 |
4 | 1113.16 | 25 | 13.09 | 1868 | 6 | 58 |
5 | 464.88 | 25 | 13.70 | 1040 | 6 | 68 |
6 | 111.32 | 25 | 14.17 | 582 | 6 | 61 |
7 | -0.00 | 24 | 14.38 | 447 | 6 | 55 |
8 | -0.12 | 311 | 13.90 | 417 | 6 | 166 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 34 | 14.36 | 500 | 6 | 7 |
2 | 2003.20 | 71 | 10.79 | 2797 | 6 | 23 |
3 | 1592.48 | 25 | 12.69 | 2434 | 6 | 45 |
4 | 1155.48 | 25 | 13.10 | 1928 | 6 | 58 |
5 | 474.92 | 25 | 13.68 | 1109 | 6 | 68 |
6 | 105.48 | 25 | 14.12 | 643 | 6 | 61 |
7 | -0.12 | 334 | 13.89 | 420 | 6 | 193 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.44 | 34 | 14.29 | 538 | 6 | 6 |
2 | 2008.00 | 70 | 10.93 | 2812 | 6 | 24 |
3 | 1576.88 | 24 | 12.77 | 2390 | 6 | 46 |
4 | 1123.72 | 25 | 13.13 | 1909 | 6 | 59 |
5 | 663.80 | 25 | 13.49 | 1363 | 6 | 69 |
6 | 89.12 | 24 | 14.12 | 618 | 6 | 62 |
7 | -0.00 | 24 | 14.37 | 470 | 6 | 65 |
8 | -0.20 | 308 | 13.85 | 423 | 6 | 142 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 34 | 14.23 | 576 | 6 | 7 |
2 | 2010.56 | 70 | 11.25 | 2768 | 7 | 27 |
3 | 1558.32 | 25 | 12.79 | 2395 | 6 | 48 |
4 | 933.44 | 25 | 13.28 | 1689 | 6 | 63 |
5 | 481.76 | 25 | 13.69 | 1134 | 6 | 70 |
6 | 107.08 | 25 | 14.10 | 653 | 6 | 64 |
7 | 18.36 | 25 | 14.29 | 518 | 6 | 59 |
8 | 0.20 | 305 | 13.81 | 438 | 6 | 146 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.16 | 34 | 14.36 | 519 | 6 | 7 |
2 | 2001.24 | 70 | 11.43 | 2772 | 6 | 28 |
3 | 1781.12 | 25 | 12.66 | 2616 | 6 | 43 |
4 | 899.80 | 25 | 13.32 | 1638 | 6 | 63 |
5 | 460.20 | 25 | 13.73 | 1089 | 6 | 69 |
6 | 54.88 | 25 | 14.26 | 555 | 6 | 56 |
7 | -0.12 | 24 | 14.40 | 451 | 6 | 60 |
8 | -0.16 | 303 | 13.95 | 411 | 6 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.96 | 34 | 14.36 | 480 | 6 | 6 |
2 | 2000.52 | 70 | 11.70 | 2752 | 6 | 30 |
3 | 1553.96 | 24 | 12.89 | 2359 | 6 | 49 |
4 | 884.80 | 25 | 13.35 | 1632 | 6 | 64 |
5 | 237.20 | 25 | 13.97 | 830 | 6 | 65 |
6 | 60.44 | 25 | 14.27 | 559 | 6 | 55 |
7 | 10.92 | 25 | 14.33 | 490 | 6 | 53 |
8 | -0.08 | 24 | 14.28 | 449 | 6 | 52 |
9 | -0.08 | 276 | 13.90 | 427 | 6 | 213 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.44 | 34 | 14.36 | 500 | 6 | 6 |
2 | 2004.64 | 70 | 11.83 | 2768 | 6 | 31 |
3 | 1337.68 | 25 | 13.05 | 2139 | 6 | 54 |
4 | 903.80 | 25 | 13.36 | 1639 | 6 | 65 |
5 | 222.76 | 25 | 14.01 | 797 | 6 | 65 |
6 | 49.96 | 24 | 14.31 | 536 | 6 | 58 |
7 | -0.20 | 324 | 13.93 | 421 | 6 | 178 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.28 | 34 | 14.42 | 500 | 6 | 6 |
2 | 2004.24 | 70 | 11.92 | 2877 | 6 | 32 |
3 | 1545.40 | 25 | 12.95 | 2370 | 6 | 49 |
4 | 1084.12 | 25 | 13.27 | 1855 | 6 | 62 |
5 | 400.16 | 25 | 13.82 | 1051 | 6 | 68 |
6 | 79.72 | 25 | 14.22 | 612 | 6 | 58 |
7 | 0.32 | 24 | 14.39 | 478 | 6 | 58 |
8 | -0.04 | 303 | 13.93 | 425 | 6 | 189 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.08 | 34 | 14.36 | 519 | 6 | 6 |
2 | 2002.36 | 70 | 12.12 | 2771 | 6 | 34 |
3 | 1555.16 | 25 | 12.99 | 2386 | 6 | 50 |
4 | 1084.40 | 25 | 13.29 | 1847 | 6 | 62 |
5 | 358.96 | 25 | 13.92 | 957 | 6 | 70 |
6 | 66.00 | 25 | 14.29 | 570 | 6 | 61 |
7 | -0.20 | 24 | 14.40 | 482 | 6 | 59 |
8 | -0.20 | 297 | 13.93 | 423 | 6 | 190 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.16 | 34 | 14.29 | 557 | 6 | 6 |
2 | 2001.48 | 70 | 12.18 | 2778 | 6 | 35 |
3 | 1555.12 | 25 | 13.03 | 2372 | 6 | 51 |
4 | 861.36 | 24 | 13.48 | 1591 | 6 | 66 |
5 | 189.44 | 25 | 14.13 | 753 | 6 | 66 |
6 | 46.12 | 25 | 14.33 | 551 | 6 | 57 |
7 | 0.76 | 318 | 13.95 | 432 | 6 | 150 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 34 | 14.36 | 557 | 6 | 6 |
2 | 2003.84 | 70 | 12.29 | 2741 | 6 | 35 |
3 | 1551.04 | 25 | 13.04 | 2409 | 6 | 51 |
4 | 857.00 | 25 | 13.52 | 1587 | 6 | 67 |
5 | 182.40 | 25 | 14.15 | 732 | 6 | 67 |
6 | 44.28 | 25 | 14.38 | 488 | 6 | 58 |
7 | 21.88 | 25 | 14.31 | 493 | 6 | 56 |
8 | -0.08 | 24 | 14.36 | 482 | 6 | 57 |
9 | -0.12 | 269 | 13.96 | 428 | 6 | 213 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.88 | 34 | 14.36 | 538 | 6 | 6 |
2 | 2003.24 | 70 | 12.30 | 2762 | 6 | 36 |
3 | 1333.52 | 25 | 13.24 | 2068 | 6 | 58 |
4 | 880.68 | 25 | 13.58 | 1515 | 6 | 67 |
5 | 171.16 | 24 | 14.23 | 641 | 6 | 67 |
6 | 43.20 | 24 | 14.40 | 515 | 6 | 56 |
7 | -0.16 | 318 | 14.02 | 422 | 6 | 187 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.24 | 34 | 14.48 | 461 | 6 | 7 |
2 | 2001.88 | 70 | 12.36 | 2770 | 7 | 35 |
3 | 1524.76 | 25 | 13.20 | 2255 | 6 | 53 |
4 | 824.60 | 25 | 13.60 | 1536 | 6 | 67 |
5 | 184.04 | 25 | 14.17 | 768 | 6 | 64 |
6 | 41.04 | 25 | 14.36 | 541 | 6 | 56 |
7 | -0.28 | 318 | 13.99 | 439 | 6 | 195 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.64 | 33 | 14.42 | 557 | 6 | 6 |
2 | 2000.64 | 70 | 12.30 | 2866 | 6 | 33 |
3 | 1561.56 | 25 | 13.12 | 2411 | 6 | 51 |
4 | 864.64 | 25 | 13.57 | 1603 | 6 | 66 |
5 | 191.44 | 25 | 14.19 | 753 | 6 | 65 |
6 | 45.16 | 24 | 14.40 | 541 | 6 | 57 |
7 | -0.16 | 25 | 14.50 | 436 | 6 | 53 |
8 | -0.20 | 292 | 14.04 | 416 | 6 | 144 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.56 | 33 | 14.42 | 538 | 6 | 6 |
2 | 2006.80 | 70 | 12.40 | 2738 | 6 | 33 |
3 | 1339.60 | 25 | 13.27 | 2182 | 6 | 57 |
4 | 889.12 | 25 | 13.55 | 1649 | 6 | 67 |
5 | 196.72 | 25 | 14.15 | 780 | 6 | 67 |
6 | 46.68 | 24 | 14.38 | 536 | 6 | 58 |
7 | -0.12 | 24 | 14.49 | 459 | 6 | 53 |
8 | -0.16 | 290 | 14.03 | 421 | 6 | 154 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 33 | 14.42 | 538 | 6 | 6 |
2 | 2001.20 | 70 | 12.41 | 2755 | 6 | 36 |
3 | 1340.12 | 25 | 13.32 | 2051 | 6 | 58 |
4 | 897.56 | 25 | 13.63 | 1538 | 6 | 68 |
5 | 197.56 | 25 | 14.16 | 799 | 6 | 67 |
6 | 45.20 | 25 | 14.38 | 549 | 6 | 61 |
7 | 0.36 | 316 | 14.02 | 425 | 6 | 173 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 33 | 14.36 | 538 | 6 | 6 |
2 | 2005.04 | 70 | 12.41 | 2747 | 6 | 35 |
3 | 1320.44 | 25 | 13.33 | 2030 | 6 | 59 |
4 | 866.88 | 25 | 13.65 | 1491 | 6 | 69 |
5 | 158.68 | 25 | 14.24 | 705 | 6 | 65 |
6 | 40.80 | 25 | 14.42 | 545 | 6 | 59 |
7 | 1.04 | 310 | 14.03 | 432 | 6 | 140 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.88 | 33 | 14.48 | 480 | 6 | 6 |
2 | 2005.00 | 70 | 12.40 | 2764 | 6 | 36 |
3 | 1319.80 | 25 | 13.35 | 2045 | 6 | 59 |
4 | 676.08 | 25 | 13.79 | 1278 | 6 | 69 |
5 | 211.20 | 25 | 14.16 | 799 | 6 | 67 |
6 | 47.96 | 25 | 14.38 | 555 | 6 | 60 |
7 | -0.24 | 24 | 14.53 | 422 | 6 | 59 |
8 | -0.28 | 287 | 14.05 | 416 | 6 | 210 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.36 | 33 | 14.48 | 500 | 6 | 6 |
2 | 2007.64 | 70 | 12.39 | 2793 | 6 | 34 |
3 | 1545.20 | 25 | 13.23 | 2272 | 6 | 54 |
4 | 855.24 | 25 | 13.57 | 1616 | 6 | 67 |
5 | 165.32 | 25 | 14.23 | 713 | 6 | 67 |
6 | 47.08 | 25 | 14.42 | 505 | 6 | 59 |
7 | 22.92 | 25 | 14.37 | 489 | 6 | 58 |
8 | -0.24 | 24 | 14.44 | 466 | 6 | 55 |
9 | -0.28 | 263 | 14.07 | 408 | 6 | 193 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.00 | 33 | 14.42 | 538 | 6 | 6 |
2 | 2005.36 | 70 | 12.41 | 2754 | 6 | 34 |
3 | 1350.12 | 25 | 13.32 | 2068 | 6 | 58 |
4 | 884.52 | 25 | 13.57 | 1634 | 6 | 68 |
5 | 171.84 | 25 | 14.23 | 707 | 6 | 69 |
6 | 40.88 | 25 | 14.40 | 540 | 6 | 63 |
7 | 1.04 | 310 | 14.05 | 414 | 6 | 165 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.40 | 33 | 14.42 | 500 | 6 | 6 |
2 | 2006.64 | 70 | 12.39 | 2763 | 6 | 34 |
3 | 1535.00 | 25 | 13.24 | 2266 | 6 | 55 |
4 | 841.64 | 25 | 13.61 | 1564 | 6 | 69 |
5 | 161.20 | 25 | 14.26 | 686 | 6 | 68 |
6 | 76.88 | 25 | 14.36 | 538 | 6 | 65 |
7 | -0.32 | 24 | 14.48 | 464 | 6 | 59 |
8 | -0.24 | 287 | 14.04 | 407 | 6 | 158 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.56 | 33 | 14.48 | 500 | 6 | 6 |
2 | 2001.20 | 70 | 12.38 | 2737 | 6 | 33 |
3 | 1318.20 | 25 | 13.30 | 2124 | 6 | 57 |
4 | 878.12 | 25 | 13.58 | 1601 | 6 | 69 |
5 | 189.88 | 25 | 14.25 | 697 | 6 | 69 |
6 | 41.08 | 25 | 14.43 | 511 | 6 | 61 |
7 | 1.68 | 313 | 14.05 | 423 | 6 | 184 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.96 | 33 | 14.42 | 500 | 6 | 6 |
2 | 2003.88 | 70 | 12.38 | 2760 | 6 | 32 |
3 | 1542.96 | 25 | 13.20 | 2299 | 6 | 54 |
4 | 1051.00 | 25 | 13.50 | 1753 | 6 | 67 |
5 | 320.72 | 25 | 14.12 | 841 | 6 | 70 |
6 | 31.36 | 25 | 14.45 | 495 | 6 | 60 |
7 | -0.24 | 313 | 14.07 | 420 | 6 | 149 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.28 | 33 | 14.42 | 500 | 6 | 6 |
2 | 2003.76 | 70 | 12.40 | 2718 | 6 | 33 |
3 | 1527.92 | 25 | 13.19 | 2320 | 6 | 54 |
4 | 832.44 | 25 | 13.64 | 1482 | 6 | 69 |
5 | 185.24 | 25 | 14.28 | 678 | 6 | 68 |
6 | 37.12 | 25 | 14.42 | 515 | 6 | 59 |
7 | 0.36 | 310 | 14.07 | 422 | 6 | 152 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 33 | 14.42 | 519 | 6 | 6 |
2 | 2004.80 | 70 | 12.40 | 2726 | 6 | 32 |
3 | 1342.12 | 25 | 13.31 | 2091 | 6 | 58 |
4 | 669.92 | 25 | 13.80 | 1297 | 6 | 69 |
5 | 126.00 | 25 | 14.34 | 628 | 6 | 63 |
6 | 27.72 | 25 | 14.48 | 478 | 6 | 57 |
7 | -0.24 | 24 | 14.47 | 443 | 6 | 55 |
8 | -0.28 | 284 | 14.09 | 401 | 6 | 156 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.48 | 33 | 14.42 | 500 | 6 | 6 |
2 | 2001.16 | 70 | 12.39 | 2752 | 6 | 32 |
3 | 1340.44 | 25 | 13.29 | 2095 | 6 | 58 |
4 | 702.08 | 25 | 13.78 | 1303 | 6 | 68 |
5 | 140.64 | 25 | 14.31 | 655 | 6 | 63 |
6 | 32.16 | 25 | 14.46 | 492 | 6 | 57 |
7 | -0.12 | 24 | 14.47 | 457 | 6 | 53 |
8 | -0.12 | 284 | 14.07 | 409 | 6 | 145 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.08 | 32 | 14.42 | 538 | 6 | 7 |
2 | 2006.12 | 70 | 12.40 | 2759 | 6 | 31 |
3 | 1344.60 | 25 | 13.34 | 2066 | 6 | 58 |
4 | 894.76 | 25 | 13.61 | 1584 | 6 | 67 |
5 | 193.32 | 25 | 14.28 | 686 | 6 | 68 |
6 | 16.84 | 25 | 14.48 | 482 | 6 | 60 |
7 | -0.28 | 308 | 14.06 | 416 | 6 | 140 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 32 | 14.42 | 557 | 6 | 6 |
2 | 2005.40 | 70 | 12.44 | 2733 | 6 | 32 |
3 | 1549.44 | 25 | 13.19 | 2293 | 6 | 54 |
4 | 660.04 | 25 | 13.80 | 1251 | 6 | 69 |
5 | 208.60 | 25 | 14.23 | 751 | 6 | 67 |
6 | 43.52 | 25 | 14.47 | 497 | 6 | 61 |
7 | 1.60 | 310 | 14.09 | 421 | 6 | 205 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.56 | 32 | 14.48 | 480 | 6 | 6 |
2 | 2003.40 | 70 | 12.51 | 2706 | 6 | 33 |
3 | 1555.28 | 25 | 13.20 | 2287 | 6 | 55 |
4 | 863.92 | 25 | 13.62 | 1545 | 6 | 66 |
5 | 171.92 | 25 | 14.26 | 728 | 6 | 65 |
6 | 37.04 | 25 | 14.49 | 511 | 6 | 58 |
7 | -0.16 | 24 | 14.50 | 468 | 6 | 55 |
8 | -0.08 | 287 | 14.04 | 437 | 6 | 202 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.08 | 32 | 14.48 | 500 | 6 | 7 |
2 | 2004.96 | 70 | 12.52 | 2738 | 6 | 32 |
3 | 1549.60 | 25 | 13.20 | 2345 | 6 | 55 |
4 | 856.44 | 25 | 13.63 | 1520 | 6 | 69 |
5 | 166.04 | 25 | 14.29 | 670 | 6 | 67 |
6 | 36.92 | 25 | 14.49 | 490 | 6 | 58 |
7 | -0.16 | 308 | 14.13 | 404 | 6 | 164 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.16 | 32 | 14.48 | 480 | 6 | 6 |
2 | 2002.24 | 70 | 12.55 | 2740 | 6 | 33 |
3 | 1328.28 | 25 | 13.34 | 2036 | 6 | 59 |
4 | 683.32 | 25 | 13.80 | 1274 | 6 | 69 |
5 | 120.32 | 25 | 14.35 | 599 | 6 | 65 |
6 | 57.52 | 25 | 14.45 | 501 | 6 | 61 |
7 | -0.20 | 308 | 14.08 | 435 | 6 | 152 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.04 | 32 | 14.48 | 500 | 6 | 6 |
2 | 2013.80 | 70 | 12.59 | 2734 | 6 | 29 |
3 | 1798.60 | 25 | 13.06 | 2578 | 6 | 49 |
4 | 837.28 | 25 | 13.66 | 1490 | 6 | 68 |
5 | 184.32 | 25 | 14.29 | 701 | 6 | 66 |
6 | 40.44 | 25 | 14.47 | 532 | 6 | 58 |
7 | -0.12 | 24 | 14.51 | 466 | 6 | 61 |
8 | -0.12 | 288 | 14.03 | 442 | 6 | 207 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.20 | 32 | 14.42 | 634 | 6 | 7 |
2 | 2005.84 | 70 | 12.62 | 2742 | 6 | 32 |
3 | 1335.08 | 25 | 13.31 | 2095 | 6 | 58 |
4 | 678.00 | 25 | 13.75 | 1316 | 6 | 69 |
5 | 125.64 | 25 | 14.39 | 595 | 6 | 64 |
6 | 24.00 | 25 | 14.54 | 453 | 6 | 59 |
7 | -0.00 | 24 | 14.55 | 410 | 6 | 61 |
8 | -0.04 | 279 | 14.10 | 398 | 6 | 179 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.84 | 32 | 14.48 | 500 | 6 | 6 |
2 | 2004.08 | 70 | 12.69 | 2681 | 6 | 34 |
3 | 1331.24 | 25 | 13.32 | 2047 | 6 | 58 |
4 | 657.48 | 25 | 13.74 | 1340 | 6 | 68 |
5 | 200.40 | 25 | 14.22 | 759 | 6 | 67 |
6 | 35.96 | 25 | 14.49 | 507 | 6 | 60 |
7 | -0.04 | 24 | 14.50 | 463 | 6 | 62 |
8 | -0.16 | 284 | 14.04 | 432 | 6 | 202 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 31 | 14.48 | 500 | 6 | 6 |
2 | 2003.08 | 70 | 12.72 | 2676 | 6 | 34 |
3 | 1352.24 | 25 | 13.29 | 2061 | 6 | 56 |
4 | 888.16 | 25 | 13.54 | 1618 | 6 | 65 |
5 | 182.56 | 25 | 14.29 | 716 | 6 | 66 |
6 | 32.20 | 25 | 14.54 | 468 | 6 | 59 |
7 | -0.12 | 24 | 14.53 | 437 | 6 | 60 |
8 | -0.16 | 281 | 14.07 | 404 | 6 | 147 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.88 | 31 | 14.48 | 519 | 6 | 6 |
2 | 2005.12 | 70 | 12.74 | 2643 | 16 | 30 |
3 | 1347.64 | 25 | 13.26 | 2076 | 6 | 54 |
4 | 702.12 | 25 | 13.69 | 1390 | 6 | 64 |
5 | 128.16 | 25 | 14.37 | 634 | 6 | 61 |
6 | -0.08 | 24 | 14.63 | 447 | 6 | 48 |
7 | -0.04 | 305 | 14.08 | 400 | 6 | 177 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 30 | 14.48 | 519 | 6 | 7 |
2 | 2001.24 | 70 | 12.66 | 2789 | 21 | 36 |
3 | 1309.72 | 25 | 13.22 | 2111 | 6 | 55 |
4 | 839.00 | 25 | 13.52 | 1611 | 6 | 67 |
5 | 163.56 | 25 | 14.26 | 745 | 6 | 67 |
6 | 33.24 | 25 | 14.49 | 530 | 6 | 59 |
7 | -0.20 | 24 | 14.48 | 484 | 6 | 63 |
8 | -0.12 | 279 | 14.02 | 409 | 6 | 165 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.84 | 30 | 14.55 | 480 | 6 | 6 |
2 | 2004.76 | 70 | 12.71 | 2656 | 30 | 34 |
3 | 1520.84 | 25 | 13.11 | 2284 | 6 | 53 |
4 | 835.68 | 25 | 13.57 | 1478 | 6 | 66 |
5 | 170.92 | 25 | 14.34 | 630 | 6 | 68 |
6 | 12.52 | 25 | 14.60 | 412 | 6 | 60 |
7 | -0.24 | 24 | 14.35 | 532 | 6 | 58 |
8 | -0.16 | 282 | 13.92 | 457 | 6 | 207 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.68 | 30 | 14.61 | 480 | 6 | 7 |
2 | 2004.56 | 70 | 12.64 | 2746 | 7 | 34 |
3 | 1548.16 | 25 | 13.06 | 2307 | 6 | 51 |
4 | 828.80 | 25 | 13.55 | 1463 | 6 | 67 |
5 | 167.20 | 25 | 14.34 | 622 | 6 | 70 |
6 | 14.24 | 25 | 14.61 | 399 | 6 | 59 |
7 | -0.36 | 295 | 14.06 | 363 | 6 | 142 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.28 | 28 | 14.55 | 500 | 6 | 7 |
2 | 1503.44 | 70 | 12.86 | 2265 | 25 | 43 |
3 | 1085.28 | 25 | 13.31 | 1807 | 6 | 57 |
4 | 609.84 | 25 | 13.73 | 1216 | 6 | 69 |
5 | 71.04 | 25 | 14.50 | 484 | 6 | 63 |
6 | -0.04 | 24 | 14.63 | 382 | 6 | 66 |
7 | -0.08 | 276 | 14.01 | 368 | 6 | 164 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.12 | 30 | 14.48 | 500 | 6 | 7 |
2 | 964.00 | -1 | 14.48 | 500 | 6 | 7 |
3 | 1086.04 | 70 | 13.10 | 1803 | 7 | 50 |
4 | 875.52 | 25 | 13.47 | 1553 | 6 | 57 |
5 | 175.64 | 25 | 14.26 | 653 | 6 | 66 |
6 | 1.80 | 25 | 14.61 | 385 | 6 | 58 |
7 | -0.00 | 289 | 13.98 | 371 | 6 | 175 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.36 | 30 | 14.42 | 500 | 6 | 8 |
2 | 1073.60 | 70 | 13.08 | 1787 | 8 | 50 |
3 | 856.12 | 25 | 13.45 | 1543 | 6 | 58 |
4 | 167.72 | 25 | 14.24 | 637 | 6 | 66 |
5 | 0.08 | 24 | 14.61 | 384 | 6 | 53 |
6 | -0.00 | 287 | 13.97 | 370 | 6 | 147 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.72 | 25 | 14.61 | 461 | 7 | 7 |
2 | 1112.00 | 2 | 14.17 | 1884 | 6 | 37 |
3 | 1245.48 | 70 | 12.79 | 2000 | 37 | 47 |
4 | 269.44 | 25 | 13.98 | 789 | 6 | 68 |
5 | 49.44 | 25 | 14.38 | 462 | 6 | 60 |
6 | -0.12 | 24 | 14.46 | 391 | 6 | 57 |
7 | -0.16 | 268 | 13.92 | 378 | 6 | 152 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 128.24 | 70 | 14.14 | 489 | 192 | 7 |
2 | 103.36 | 25 | 14.53 | 464 | 7 | 9 |
3 | 57.48 | 25 | 14.61 | 403 | 7 | 11 |
4 | 0.24 | 299 | 14.35 | 320 | 7 | 186 |