SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8536 WMO= 3901247


Cycle 271 GMT 17/ 4/2023 21:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 39 10.76 432 2 2
2 10 1028.64 6 8.53 1709 2 2
3 5 1341.28 10 7.79 2096 2 2
4 5 1310.92 10 7.92 2038 2 2
5 5 1398.16 10 7.55 2171 2 2
6 5 1357.08 10 7.72 2091 2 2
7 5 1318.96 10 7.79 2056 2 2
8 5 1397.84 10 7.50 2186 2 2
9 5 1378.16 10 7.68 2142 2 2
10 5 1339.44 10 7.55 2076 2 2
11 5 1313.40 10 7.80 2051 2 2
12 5 1387.12 10 7.42 2132 2 2
13 5 1363.28 10 7.67 2102 2 2
14 5 1352.56 10 7.72 2092 2 2
15 5 1328.52 10 7.90 2066 2 2
16 5 1396.68 10 7.53 2210 2 2
17 5 1375.80 10 7.38 2174 2 2
18 5 1355.04 10 7.55 2149 2 2
19 5 1335.56 10 7.76 2074 2 2
20 5 1307.12 10 7.61 2032 2 2
21 5 1399.00 10 7.59 2160 2 2
22 5 1369.08 10 7.62 2124 2 2
23 5 1366.72 10 7.49 2134 2 2
24 5 1351.16 10 7.72 2068 2 2
25 5 1328.16 10 7.76 2059 2 2
26 5 1313.88 10 7.69 2014 2 2
27 5 1379.04 10 7.51 2182 2 2
28 5 1377.20 10 7.50 2166 2 2
29 5 1353.84 10 7.61 2144 2 2
30 5 1337.88 10 7.87 2097 2 2
31 5 1307.32 10 7.75 2074 2 2
32 5 1384.24 10 7.57 2123 2 2
33 5 1378.76 10 7.36 2116 2 2
34 5 1362.76 10 7.55 2112 2 2
35 5 1355.12 10 7.59 2142 2 2
36 5 1348.44 10 7.65 2139 2 2
37 5 1320.52 10 7.80 2052 2 2
38 5 1307.68 10 7.77 2034 2 2
39 5 1385.00 10 7.74 2143 2 2
40 5 1369.48 10 7.62 2118 2 2
41 5 1357.08 10 7.56 2048 2 2
42 5 1341.56 10 7.53 2124 2 2
43 5 1392.40 10 7.30 2130 2 2
44 5 1368.84 10 7.51 2090 2 2
45 5 1336.60 10 7.66 2060 2 2
46 5 1304.36 10 7.64 2054 2 2
47 5 1369.24 10 7.40 2074 2 2
48 5 1334.08 10 7.55 2063 2 2
49 5 1410.40 10 7.28 2143 2 2
50 12 1503.88 104 7.23 2300 2 2
51 7 1499.92 24 7.38 2298 2 2
52 13 1369.80 45 7.52 2158 2 2
53 13 836.64 45 8.69 1463 2 2
54 13 134.04 45 10.44 493 2 2
55 13 29.24 45 10.74 333 2 2
56 8 -0.08 165 10.83 289 2 2

Cycle 270 GMT 8/ 4/2023 6:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 24 10.80 427 2 2
2 10 1024.20 9 8.84 1718 2 2
3 10 1078.64 8 8.71 1778 2 2
4 10 1126.84 7 8.63 1840 2 2
5 5 1353.16 10 7.88 2108 2 2
6 5 1316.36 10 8.00 2083 2 2
7 5 1377.68 10 7.71 2128 2 2
8 5 1341.08 10 7.93 2080 2 2
9 5 1389.04 10 7.86 2175 2 2
10 5 1370.64 10 7.91 2104 2 2
11 5 1331.52 10 7.92 2062 2 2
12 5 1363.28 10 7.83 2129 2 2
13 5 1331.08 10 7.85 2080 2 2
14 5 1424.48 10 7.88 2189 2 2
15 5 1382.48 10 7.81 2145 2 2
16 5 1350.68 10 7.83 2083 2 2
17 5 1301.08 10 8.01 2051 2 2
18 5 1380.20 10 7.84 2144 2 2
19 5 1341.92 10 7.94 2083 2 2
20 5 1302.64 10 7.96 2024 2 2
21 5 1383.88 10 7.88 2130 2 2
22 5 1354.08 10 7.81 2108 2 2
23 5 1337.12 10 7.88 2074 2 2
24 5 1396.76 10 7.67 2136 2 2
25 5 1390.16 10 7.63 2146 2 2
26 5 1356.24 10 7.64 2151 2 2
27 5 1333.24 10 7.93 2093 2 2
28 5 1395.72 10 7.63 2136 2 2
29 5 1361.20 10 7.83 2115 2 2
30 5 1332.48 10 8.00 2048 2 2
31 5 1378.96 10 7.79 2136 2 2
32 5 1334.40 10 7.92 2069 2 2
33 5 1367.96 10 7.72 2134 2 2
34 5 1348.56 10 7.79 2090 2 2
35 5 1372.16 10 7.89 2094 2 2
36 5 1335.68 10 7.74 2096 2 2
37 5 1386.36 10 7.60 2143 2 2
38 5 1342.56 10 7.84 2078 2 2
39 5 1310.00 10 7.91 2048 2 2
40 5 1367.00 10 7.48 2113 2 2
41 5 1353.20 10 7.83 2079 2 2
42 5 1322.56 10 7.98 2046 2 2
43 5 1380.32 10 7.70 2172 2 2
44 5 1347.16 10 7.69 2117 2 2
45 5 1340.56 10 7.70 2131 2 2
46 5 1301.36 10 7.88 2070 2 2
47 5 1396.40 10 7.56 2145 2 2
48 5 1366.44 10 7.74 2155 2 2
49 12 1449.76 104 7.56 2237 2 2
50 7 1445.56 24 7.60 2241 2 2
51 13 1319.68 45 7.86 2066 2 2
52 13 760.48 45 9.02 1360 2 2
53 13 69.08 45 10.66 403 2 2
54 13 20.72 45 10.80 323 2 2
55 8 -0.04 165 10.86 294 2 2

Cycle 269 GMT 29/ 3/2023 15:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 24 10.82 427 2 2
2 10 1018.40 10 8.98 1731 2 2
3 10 1064.16 7 8.90 1780 2 2
4 10 1099.92 5 8.79 1822 2 2
5 10 1127.24 4 8.74 1887 2 2
6 5 1302.96 10 8.07 2050 2 2
7 5 1366.40 10 8.08 2153 2 2
8 5 1337.88 10 8.06 2129 2 2
9 5 1306.80 10 8.18 2110 2 2
10 5 1356.28 10 8.07 2137 2 2
11 5 1319.56 10 8.14 2065 2 2
12 5 1344.12 10 7.97 2174 2 2
13 5 1308.12 10 8.05 2110 2 2
14 5 1359.72 10 7.97 2114 2 2
15 5 1312.24 10 8.14 2115 2 2
16 5 1385.28 10 7.97 2152 2 2
17 5 1341.12 10 8.09 2094 2 2
18 5 1415.56 10 8.00 2205 2 2
19 5 1378.68 10 8.02 2136 2 2
20 5 1345.96 10 8.16 2117 2 2
21 5 1408.84 10 7.72 2178 2 2
22 5 1383.60 10 8.07 2129 2 2
23 5 1340.44 10 8.15 2077 2 2
24 5 1382.24 10 8.02 2132 2 2
25 5 1352.48 10 7.90 2083 2 2
26 5 1306.28 10 7.95 2117 2 2
27 5 1352.12 10 8.04 2099 2 2
28 5 1307.04 10 8.19 2051 2 2
29 5 1347.52 10 7.95 2116 2 2
30 5 1312.92 10 8.07 2100 2 2
31 5 1382.44 10 8.07 2133 2 2
32 5 1351.68 10 7.95 2138 2 2
33 5 1314.96 10 8.09 2042 2 2
34 5 1372.32 10 7.96 2121 2 2
35 5 1341.64 10 8.07 2095 2 2
36 5 1393.12 10 7.84 2198 2 2
37 5 1344.40 10 7.69 2144 2 2
38 5 1329.04 10 8.09 2097 2 2
39 5 1386.16 10 7.76 2184 2 2
40 5 1361.24 10 7.76 2115 2 2
41 5 1320.40 10 8.08 2055 2 2
42 5 1394.36 10 7.83 2160 2 2
43 5 1358.88 10 7.97 2119 2 2
44 5 1322.24 10 8.16 2061 2 2
45 5 1401.64 10 7.81 2198 2 2
46 5 1377.32 10 7.69 2132 2 2
47 5 1352.52 10 7.98 2102 2 2
48 12 1491.64 104 7.68 2288 2 2
49 7 1487.00 24 7.84 2279 2 2
50 13 1233.36 45 8.21 1970 2 2
51 13 667.12 45 9.32 1254 2 2
52 13 55.04 45 10.75 370 2 2
53 8 0.08 165 10.88 296 2 2

Cycle 268 GMT 20/ 3/2023 0:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 38 10.82 422 2 2
2 10 1048.20 7 8.88 1730 2 2
3 5 1372.44 10 7.98 2130 2 2
4 5 1303.72 10 8.28 2062 2 2
5 5 1322.24 10 8.14 2074 2 2
6 5 1328.84 10 8.21 2064 2 2
7 12 1466.36 5 7.84 2262 2 2
8 12 2000.24 104 6.89 3025 2 2
9 7 1995.52 24 7.10 3000 2 2
10 13 1743.44 45 7.45 2676 2 2
11 13 1222.68 45 8.44 1985 2 2
12 13 635.60 45 9.52 1211 2 2
13 13 46.00 45 10.81 365 2 2
14 8 0.12 165 10.91 301 2 2

Cycle 267 GMT 18/ 3/2023 2:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 39 10.83 420 2 2
2 10 1010.04 5 9.12 1674 2 2
3 5 1304.40 10 8.39 2072 2 2
4 5 1342.64 10 8.37 2104 2 2
5 5 1370.40 10 8.36 2134 2 2
6 5 1329.32 10 8.31 2087 2 2
7 5 1377.12 10 8.15 2159 2 2
8 5 1328.40 10 8.32 2075 2 2
9 5 1355.68 10 8.20 2171 2 2
10 5 1303.40 10 8.21 2098 2 2
11 5 1357.76 10 8.13 2152 2 2
12 5 1307.52 10 8.24 2095 2 2
13 5 1364.32 10 8.25 2164 2 2
14 5 1325.24 10 8.28 2099 2 2
15 5 1351.00 10 8.09 2090 2 2
16 5 1394.44 10 8.08 2176 2 2
17 5 1355.96 10 8.22 2125 2 2
18 5 1302.72 10 8.27 2069 2 2
19 5 1339.72 10 8.02 2150 2 2
20 5 1303.84 10 8.26 2053 2 2
21 5 1344.64 10 8.31 2100 2 2
22 5 1311.24 10 8.29 2121 2 2
23 5 1365.88 10 7.96 2173 2 2
24 5 1323.20 10 8.24 2105 2 2
25 5 1381.84 10 8.08 2218 2 2
26 5 1349.52 10 8.18 2162 2 2
27 5 1303.08 10 8.22 2069 2 2
28 5 1353.16 10 8.18 2102 2 2
29 5 1317.84 10 8.30 2087 2 2
30 5 1346.92 10 8.23 2102 2 2
31 5 1317.24 10 8.29 2092 2 2
32 5 1341.24 10 8.18 2095 2 2
33 5 1400.64 10 8.08 2172 2 2
34 5 1361.68 10 8.12 2156 2 2
35 5 1304.40 10 8.28 2033 2 2
36 5 1340.92 10 8.07 2117 2 2
37 5 1385.20 10 8.17 2152 2 2
38 5 1357.36 10 8.18 2097 2 2
39 5 1316.04 10 8.24 2072 2 2
40 5 1374.96 10 8.08 2122 2 2
41 5 1338.76 10 8.20 2062 2 2
42 12 1382.16 104 8.16 2147 2 2
43 7 1378.16 24 8.19 2162 2 2
44 13 989.12 45 8.89 1659 2 2
45 13 275.92 45 10.28 703 2 2
46 13 26.24 45 10.85 332 2 2
47 8 0.04 165 10.91 294 2 2

Cycle 266 GMT 8/ 3/2023 12: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 24 10.85 434 2 2
2 10 1009.08 10 9.25 1713 2 2
3 10 1064.52 8 9.12 1793 2 2
4 10 1098.32 5 9.01 1825 2 2
5 5 1302.48 10 8.52 2065 2 2
6 5 1321.52 10 8.56 2108 2 2
7 5 1362.00 10 8.33 2126 2 2
8 5 1403.36 10 8.28 2254 2 2
9 5 1356.08 10 8.36 2137 2 2
10 5 1392.76 10 8.35 2173 2 2
11 5 1348.20 10 8.22 2102 2 2
12 5 1395.68 10 8.33 2172 2 2
13 5 1334.48 10 8.34 2124 2 2
14 5 1367.44 10 8.44 2134 2 2
15 5 1326.76 10 8.40 2071 2 2
16 5 1346.40 10 8.32 2140 2 2
17 5 1388.28 10 8.27 2201 2 2
18 5 1352.28 10 8.31 2177 2 2
19 5 1386.80 10 8.30 2158 2 2
20 5 1326.56 10 8.38 2068 2 2
21 5 1360.72 10 8.40 2132 2 2
22 5 1320.12 10 8.47 2081 2 2
23 5 1353.92 10 8.37 2113 2 2
24 5 1311.12 10 8.49 2061 2 2
25 5 1347.88 10 8.34 2160 2 2
26 5 1362.16 10 8.24 2172 2 2
27 5 1319.08 10 8.25 2163 2 2
28 5 1354.32 10 8.15 2114 2 2
29 5 1389.52 10 8.24 2155 2 2
30 5 1329.72 10 8.38 2092 2 2
31 5 1386.72 10 8.33 2160 2 2
32 5 1339.12 10 8.33 2092 2 2
33 5 1376.76 10 8.42 2138 2 2
34 5 1330.16 10 8.31 2116 2 2
35 5 1372.36 10 8.30 2116 2 2
36 5 1319.72 10 8.36 2074 2 2
37 5 1343.80 10 8.29 2081 2 2
38 5 1403.04 10 8.13 2181 2 2
39 5 1347.08 10 8.36 2118 2 2
40 5 1389.80 10 8.33 2152 2 2
41 5 1339.72 10 8.42 2083 2 2
42 12 1498.08 104 8.06 2325 2 2
43 7 1493.56 24 8.05 2315 2 2
44 13 1214.44 45 8.60 1964 2 2
45 13 348.72 45 10.19 805 2 2
46 13 44.24 45 10.85 354 2 2
47 8 0.12 165 10.93 293 2 2

Cycle 265 GMT 26/ 2/2023 21: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 24 10.88 438 2 2
2 10 1015.80 10 9.34 1715 2 2
3 10 1067.92 7 9.28 1782 2 2
4 10 1111.76 6 9.09 1841 2 2
5 5 1321.08 10 8.58 2113 2 2
6 5 1346.76 10 8.60 2124 2 2
7 5 1383.16 10 8.52 2165 2 2
8 5 1323.32 10 8.71 2075 2 2
9 5 1357.32 10 8.54 2105 2 2
10 5 1300.60 10 8.49 2086 2 2
11 5 1311.92 10 8.53 2113 2 2
12 5 1377.88 10 8.40 2206 2 2
13 5 1311.84 10 8.62 2084 2 2
14 5 1333.08 10 8.54 2146 2 2
15 5 1360.24 10 8.37 2198 2 2
16 5 1311.52 10 8.47 2084 2 2
17 5 1352.72 10 8.26 2150 2 2
18 5 1410.88 10 8.25 2197 2 2
19 5 1354.44 10 8.49 2139 2 2
20 5 1383.56 10 8.33 2190 2 2
21 5 1351.28 10 8.27 2162 2 2
22 5 1381.80 10 8.42 2142 2 2
23 5 1334.68 10 8.49 2138 2 2
24 5 1378.20 10 8.38 2190 2 2
25 5 1354.48 10 8.53 2144 2 2
26 5 1371.72 10 8.40 2143 2 2
27 5 1327.48 10 8.39 2154 2 2
28 5 1330.48 10 8.51 2083 2 2
29 5 1364.76 10 8.48 2142 2 2
30 5 1395.84 10 8.38 2145 2 2
31 5 1336.08 10 8.43 2083 2 2
32 5 1360.88 10 8.45 2110 2 2
33 5 1306.52 10 8.48 2122 2 2
34 5 1336.20 10 8.55 2095 2 2
35 5 1363.72 10 8.22 2165 2 2
36 5 1303.28 10 8.46 2096 2 2
37 5 1326.04 10 8.41 2133 2 2
38 5 1351.08 10 8.40 2088 2 2
39 5 1374.24 10 8.33 2169 2 2
40 5 1346.16 10 8.43 2155 2 2
41 5 1300.44 10 8.48 2096 2 2
42 12 1369.08 104 8.41 2175 2 2
43 7 1364.04 24 8.55 2160 2 2
44 13 1067.00 45 8.99 1774 2 2
45 13 179.00 45 10.56 573 2 2
46 13 36.72 45 10.86 355 2 2
47 8 -0.04 165 10.94 301 2 2

Cycle 264 GMT 17/ 2/2023 6:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 38 10.87 441 2 2
2 10 1041.24 6 9.27 1753 2 2
3 5 1336.20 10 8.64 2110 2 2
4 5 1377.96 10 8.66 2151 2 2
5 5 1373.72 10 8.59 2174 2 2
6 5 1380.84 10 8.42 2230 2 2
7 5 1301.44 10 8.67 2092 2 2
8 12 1339.88 5 8.62 2142 2 2
9 12 2004.92 104 7.58 3019 2 2
10 7 1999.72 24 7.67 3015 2 2
11 13 1596.20 45 8.25 2489 2 2
12 13 1027.00 45 9.14 1736 2 2
13 13 142.24 45 10.68 518 2 2
14 13 29.80 45 10.91 345 2 2
15 8 0.00 165 10.96 303 2 2

Cycle 263 GMT 15/ 2/2023 8: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 39 10.90 430 2 2
2 10 1042.88 5 9.32 1739 2 2
3 5 1367.04 10 8.70 2136 2 2
4 5 1399.64 10 8.66 2179 2 2
5 5 1337.32 10 8.63 2182 2 2
6 5 1374.20 10 8.57 2187 2 2
7 5 1311.48 10 8.61 2106 2 2
8 5 1317.12 10 8.76 2087 2 2
9 5 1332.84 10 8.66 2090 2 2
10 5 1352.56 10 8.44 2157 2 2
11 5 1388.76 10 8.52 2215 2 2
12 5 1335.20 10 8.66 2142 2 2
13 5 1356.72 10 8.58 2108 2 2
14 5 1381.76 10 8.50 2227 2 2
15 5 1317.88 10 8.55 2128 2 2
16 5 1343.68 10 8.61 2083 2 2
17 5 1375.76 10 8.56 2203 2 2
18 5 1326.64 10 8.49 2109 2 2
19 5 1327.76 10 8.59 2088 2 2
20 5 1367.92 10 8.51 2169 2 2
21 5 1300.96 10 8.66 2084 2 2
22 5 1322.60 10 8.64 2082 2 2
23 5 1356.56 10 8.66 2141 2 2
24 5 1397.00 10 8.46 2222 2 2
25 5 1355.52 10 8.44 2126 2 2
26 5 1414.36 10 8.30 2201 2 2
27 5 1356.24 10 8.55 2136 2 2
28 5 1394.16 10 8.35 2201 2 2
29 5 1358.36 10 8.50 2149 2 2
30 5 1392.04 10 8.49 2152 2 2
31 5 1315.44 10 8.71 2076 2 2
32 5 1350.84 10 8.51 2081 2 2
33 5 1306.32 10 8.60 2097 2 2
34 5 1316.12 10 8.42 2095 2 2
35 5 1349.32 10 8.61 2109 2 2
36 5 1396.60 10 8.53 2185 2 2
37 5 1322.84 10 8.47 2099 2 2
38 12 1478.72 104 8.41 2291 2 2
39 7 1474.00 24 8.45 2310 2 2
40 13 1199.76 45 8.89 1959 2 2
41 13 436.32 45 10.13 941 2 2
42 13 52.52 45 10.86 378 2 2
43 8 -0.04 165 10.96 302 2 2

Cycle 262 GMT 5/ 2/2023 17:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 24 10.92 437 2 2
2 10 1027.32 10 9.42 1745 2 2
3 10 1079.84 8 9.42 1799 2 2
4 10 1117.92 5 9.23 1850 2 2
5 5 1319.12 10 8.85 2128 2 2
6 5 1354.56 10 8.87 2167 2 2
7 5 1368.36 10 8.72 2177 2 2
8 5 1388.92 10 8.48 2226 2 2
9 5 1313.32 10 8.82 2105 2 2
10 5 1341.96 10 8.76 2127 2 2
11 5 1361.72 10 8.70 2143 2 2
12 5 1383.28 10 8.63 2220 2 2
13 5 1321.92 10 8.74 2160 2 2
14 5 1324.12 10 8.74 2092 2 2
15 5 1364.52 10 8.63 2143 2 2
16 5 1395.76 10 8.71 2174 2 2
17 5 1329.68 10 8.72 2157 2 2
18 5 1356.08 10 8.74 2135 2 2
19 5 1367.24 10 8.72 2157 2 2
20 5 1305.52 10 8.74 2068 2 2
21 5 1334.92 10 8.71 2100 2 2
22 5 1348.16 10 8.57 2117 2 2
23 5 1393.52 10 8.46 2168 2 2
24 5 1322.28 10 8.74 2076 2 2
25 5 1341.00 10 8.67 2109 2 2
26 5 1378.68 10 8.72 2157 2 2
27 5 1316.32 10 8.64 2069 2 2
28 5 1328.64 10 8.70 2103 2 2
29 5 1345.80 10 8.64 2194 2 2
30 5 1366.48 10 8.51 2162 2 2
31 5 1406.36 10 8.54 2216 2 2
32 5 1339.96 10 8.68 2106 2 2
33 5 1366.56 10 8.78 2143 2 2
34 5 1305.72 10 8.69 2036 2 2
35 5 1329.88 10 8.72 2080 2 2
36 5 1367.96 10 8.66 2117 2 2
37 5 1415.64 10 8.60 2228 2 2
38 5 1354.60 10 8.56 2112 2 2
39 5 1300.20 10 8.76 2094 2 2
40 12 1318.60 104 8.75 2100 2 2
41 7 1313.76 24 8.84 2094 2 2
42 13 771.76 45 9.63 1384 2 2
43 13 84.48 45 10.81 429 2 2
44 8 0.16 165 10.98 298 2 2

Cycle 261 GMT 27/ 1/2023 2:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 24 10.93 435 2 2
2 10 1012.24 11 9.58 1728 2 2
3 10 1053.00 6 9.41 1790 2 2
4 10 1091.04 5 9.35 1820 2 2
5 5 1334.24 10 8.80 2145 2 2
6 5 1344.80 10 8.82 2201 2 2
7 5 1318.00 10 8.82 2130 2 2
8 5 1347.32 10 8.81 2137 2 2
9 5 1377.96 10 8.75 2183 2 2
10 5 1374.56 10 8.74 2205 2 2
11 5 1380.64 10 8.62 2202 2 2
12 5 1381.40 10 8.70 2212 2 2
13 5 1303.20 10 8.75 2103 2 2
14 5 1316.52 10 8.78 2063 2 2
15 5 1340.12 10 8.79 2097 2 2
16 5 1366.88 10 8.85 2137 2 2
17 5 1309.28 10 8.82 2080 2 2
18 5 1314.76 10 8.88 2102 2 2
19 5 1356.68 10 8.82 2133 2 2
20 5 1391.48 10 8.73 2197 2 2
21 5 1321.60 10 8.81 2110 2 2
22 5 1353.64 10 8.78 2150 2 2
23 5 1367.92 10 8.75 2137 2 2
24 5 1381.00 10 8.70 2185 2 2
25 5 1319.52 10 8.76 2097 2 2
26 5 1358.56 10 8.75 2132 2 2
27 5 1372.96 10 8.65 2140 2 2
28 5 1321.00 10 8.80 2116 2 2
29 5 1347.88 10 8.88 2102 2 2
30 5 1367.92 10 8.79 2167 2 2
31 5 1392.92 10 8.71 2171 2 2
32 5 1335.24 10 8.75 2132 2 2
33 5 1386.40 10 8.67 2207 2 2
34 5 1332.52 10 8.75 2106 2 2
35 5 1345.44 10 8.74 2140 2 2
36 5 1378.20 10 8.68 2234 2 2
37 5 1302.12 10 8.86 2108 2 2
38 5 1331.32 10 8.78 2128 2 2
39 12 1371.80 104 8.76 2178 2 2
40 7 1366.92 24 8.87 2159 2 2
41 13 813.72 45 9.63 1451 2 2
42 13 104.52 45 10.78 472 2 2
43 8 0.04 165 10.99 303 2 2

Cycle 260 GMT 17/ 1/2023 12: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 38 10.92 442 2 2
2 10 1034.28 7 9.49 1740 2 2
3 5 1402.32 10 8.80 2242 2 2
4 5 1328.64 10 8.88 2143 2 2
5 5 1313.76 10 8.92 2123 2 2
6 5 1355.68 10 8.79 2160 2 2
7 12 1436.40 5 8.69 2290 2 2
8 12 2004.44 104 8.00 3033 2 2
9 7 1999.48 24 8.13 3026 2 2
10 13 1451.24 45 8.82 2293 2 2
11 13 729.08 45 9.83 1346 2 2
12 13 71.72 45 10.89 407 2 2
13 8 0.08 165 11.01 302 2 2

Cycle 259 GMT 15/ 1/2023 14: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 39 10.96 436 2 2
2 10 1075.24 5 9.44 1799 2 2
3 5 1366.92 10 9.00 2183 2 2
4 5 1381.24 10 8.82 2200 2 2
5 5 1314.60 10 9.05 2136 2 2
6 5 1331.40 10 8.95 2084 2 2
7 5 1357.12 10 8.87 2121 2 2
8 5 1368.00 10 8.86 2136 2 2
9 5 1300.80 10 8.93 2092 2 2
10 5 1303.00 10 9.00 2063 2 2
11 5 1314.48 10 8.96 2115 2 2
12 5 1347.44 10 8.80 2166 2 2
13 5 1388.28 10 8.65 2221 2 2
14 5 1325.40 10 8.80 2105 2 2
15 5 1335.36 10 8.80 2149 2 2
16 5 1349.40 10 8.81 2159 2 2
17 5 1338.48 10 8.93 2145 2 2
18 5 1376.64 10 8.82 2202 2 2
19 5 1375.76 10 8.90 2168 2 2
20 5 1305.36 10 8.93 2123 2 2
21 5 1323.00 10 8.79 2082 2 2
22 5 1328.80 10 8.89 2129 2 2
23 5 1329.52 10 8.87 2110 2 2
24 5 1351.76 10 8.69 2155 2 2
25 5 1384.48 10 8.91 2166 2 2
26 5 1322.20 10 8.90 2103 2 2
27 5 1337.24 10 8.92 2126 2 2
28 5 1362.92 10 8.91 2115 2 2
29 5 1374.32 10 8.79 2152 2 2
30 5 1395.88 10 8.82 2227 2 2
31 5 1330.28 10 8.84 2113 2 2
32 5 1354.68 10 8.93 2105 2 2
33 5 1365.40 10 8.86 2155 2 2
34 5 1382.20 10 8.69 2146 2 2
35 5 1304.52 10 8.93 2044 2 2
36 12 1336.28 104 8.93 2123 2 2
37 7 1331.24 24 8.98 2143 2 2
38 13 778.52 45 9.77 1391 2 2
39 13 91.24 45 10.84 439 2 2
40 8 0.00 165 11.00 301 2 2

Cycle 258 GMT 5/ 1/2023 23:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 24 10.97 441 2 2
2 10 1017.88 10 9.64 1739 2 2
3 10 1056.32 6 9.70 1776 2 2
4 10 1100.16 6 9.62 1841 2 2
5 5 1320.20 10 9.19 2132 2 2
6 5 1338.00 10 9.03 2157 2 2
7 5 1337.72 10 9.12 2126 2 2
8 5 1351.64 10 8.94 2125 2 2
9 5 1355.00 10 8.99 2131 2 2
10 5 1369.64 10 8.94 2135 2 2
11 5 1399.68 10 8.85 2203 2 2
12 5 1335.80 10 9.03 2167 2 2
13 5 1345.88 10 8.95 2143 2 2
14 5 1375.84 10 8.84 2153 2 2
15 5 1381.24 10 8.84 2205 2 2
16 5 1388.96 10 8.86 2178 2 2
17 5 1327.80 10 9.04 2150 2 2
18 5 1332.68 10 9.03 2105 2 2
19 5 1353.28 10 9.00 2134 2 2
20 5 1377.72 10 8.93 2166 2 2
21 5 1304.20 10 8.99 2115 2 2
22 5 1317.08 10 8.99 2116 2 2
23 5 1342.68 10 8.87 2135 2 2
24 5 1354.16 10 8.85 2133 2 2
25 5 1363.76 10 8.98 2168 2 2
26 5 1393.96 10 8.80 2210 2 2
27 5 1330.40 10 9.00 2128 2 2
28 5 1358.88 10 9.06 2134 2 2
29 5 1360.76 10 9.00 2122 2 2
30 5 1301.32 10 9.01 2086 2 2
31 5 1314.16 10 9.02 2100 2 2
32 5 1344.48 10 9.00 2107 2 2
33 5 1366.40 10 8.77 2161 2 2
34 5 1310.08 10 9.02 2098 2 2
35 5 1322.24 10 9.00 2116 2 2
36 5 1355.60 10 8.95 2156 2 2
37 5 1390.36 10 8.89 2153 2 2
38 12 1423.84 104 8.87 2246 2 2
39 7 1418.64 24 8.96 2248 2 2
40 13 849.32 45 9.71 1494 2 2
41 13 113.20 45 10.82 472 2 2
42 8 0.04 165 11.02 300 2 2

Cycle 257 GMT 27/12/2022 8:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 24 10.98 428 2 2
2 10 1011.36 9 9.75 1710 2 2
3 10 1064.68 8 9.70 1794 2 2
4 10 1104.60 6 9.61 1826 2 2
5 5 1388.44 10 9.05 2239 2 2
6 5 1327.60 10 9.17 2145 2 2
7 5 1313.16 10 9.13 2112 2 2
8 5 1353.24 10 9.09 2184 2 2
9 5 1338.88 10 8.96 2156 2 2
10 5 1339.72 10 9.04 2155 2 2
11 5 1375.16 10 8.93 2220 2 2
12 5 1381.16 10 8.97 2213 2 2
13 5 1309.24 10 9.05 2151 2 2
14 5 1305.36 10 8.96 2133 2 2
15 5 1331.64 10 9.05 2149 2 2
16 5 1361.52 10 9.05 2172 2 2
17 5 1400.92 10 8.92 2249 2 2
18 5 1318.72 10 9.04 2117 2 2
19 5 1319.52 10 9.09 2112 2 2
20 5 1322.76 10 9.09 2094 2 2
21 5 1312.52 10 9.09 2075 2 2
22 5 1336.96 10 8.92 2115 2 2
23 5 1340.92 10 9.10 2162 2 2
24 5 1363.16 10 9.03 2160 2 2
25 5 1383.80 10 8.90 2228 2 2
26 5 1317.76 10 9.04 2113 2 2
27 5 1328.24 10 9.07 2104 2 2
28 5 1322.24 10 8.99 2121 2 2
29 5 1313.44 10 9.08 2063 2 2
30 5 1331.24 10 9.09 2131 2 2
31 5 1351.36 10 9.01 2179 2 2
32 5 1355.72 10 8.94 2120 2 2
33 5 1348.28 10 8.99 2129 2 2
34 5 1349.56 10 9.06 2120 2 2
35 5 1380.20 10 8.84 2182 2 2
36 12 1480.60 104 8.86 2316 2 2
37 7 1475.52 24 8.94 2311 2 2
38 13 795.68 45 9.83 1442 2 2
39 13 101.44 45 10.85 462 2 2
40 8 0.16 165 11.02 306 2 2

Cycle 256 GMT 17/12/2022 17:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 38 10.97 438 2 2
2 10 1030.40 6 9.67 1733 2 2
3 5 1319.24 10 9.23 2107 2 2
4 5 1342.96 10 9.15 2149 2 2
5 5 1317.72 10 9.15 2147 2 2
6 5 1303.96 10 9.15 2120 2 2
7 12 1370.32 5 9.09 2147 2 2
8 12 1996.32 104 8.34 3020 2 2
9 7 1990.44 24 8.45 3027 2 2
10 13 1423.64 45 9.16 2266 2 2
11 13 560.08 45 10.21 1116 2 2
12 13 53.32 45 10.95 385 2 2
13 8 0.04 165 11.03 301 2 2

Cycle 255 GMT 15/12/2022 19:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 39 10.98 444 2 2
2 10 1043.00 5 9.73 1769 2 2
3 5 1343.32 10 9.16 2162 2 2
4 5 1397.32 10 9.17 2198 2 2
5 5 1319.52 10 9.23 2119 2 2
6 5 1331.96 10 9.08 2112 2 2
7 5 1343.88 10 9.17 2123 2 2
8 5 1365.56 10 9.10 2194 2 2
9 5 1373.60 10 9.08 2181 2 2
10 5 1383.28 10 9.10 2194 2 2
11 5 1314.60 10 9.17 2130 2 2
12 5 1337.16 10 9.08 2129 2 2
13 5 1371.88 10 9.09 2188 2 2
14 5 1394.04 10 9.02 2209 2 2
15 5 1331.80 10 9.12 2117 2 2
16 5 1333.16 10 9.23 2096 2 2
17 5 1344.12 10 9.11 2121 2 2
18 5 1372.00 10 9.05 2165 2 2
19 5 1371.36 10 9.10 2161 2 2
20 5 1407.76 10 8.92 2213 2 2
21 5 1334.08 10 9.20 2146 2 2
22 5 1349.84 10 9.10 2126 2 2
23 5 1368.16 10 9.11 2195 2 2
24 5 1379.48 10 9.06 2237 2 2
25 5 1305.16 10 9.09 2086 2 2
26 5 1329.76 10 9.18 2145 2 2
27 5 1354.36 10 9.11 2127 2 2
28 5 1387.64 10 9.09 2205 2 2
29 5 1318.04 10 9.14 2109 2 2
30 5 1307.12 10 9.16 2087 2 2
31 5 1327.36 10 9.10 2150 2 2
32 5 1340.12 10 9.07 2156 2 2
33 5 1346.44 10 9.09 2153 2 2
34 5 1378.40 10 9.05 2202 2 2
35 5 1301.80 10 9.17 2080 2 2
36 12 1340.88 104 9.16 2148 2 2
37 7 1335.52 24 9.23 2143 2 2
38 13 762.92 45 9.92 1400 2 2
39 13 73.48 45 10.92 413 2 2
40 8 0.04 165 11.03 301 2 2

Cycle 254 GMT 6/12/2022 5:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 24 10.97 439 2 2
2 10 1012.88 9 9.85 1725 2 2
3 10 1060.20 7 9.82 1801 2 2
4 10 1093.80 5 9.75 1834 2 2
5 5 1337.44 10 9.29 2162 2 2
6 5 1391.96 10 9.19 2209 2 2
7 5 1394.72 10 9.19 2230 2 2
8 5 1312.56 10 9.19 2119 2 2
9 5 1317.12 10 9.26 2131 2 2
10 5 1305.08 10 9.20 2066 2 2
11 5 1342.36 10 9.21 2128 2 2
12 5 1357.40 10 9.17 2151 2 2
13 5 1379.16 10 9.19 2211 2 2
14 5 1315.08 10 9.24 2116 2 2
15 5 1358.48 10 9.18 2152 2 2
16 5 1388.68 10 9.18 2199 2 2
17 5 1314.60 10 9.22 2124 2 2
18 5 1335.40 10 9.21 2156 2 2
19 5 1379.28 10 9.17 2167 2 2
20 5 1308.36 10 9.25 2111 2 2
21 5 1313.84 10 9.25 2103 2 2
22 5 1346.88 10 9.23 2160 2 2
23 5 1342.88 10 9.13 2142 2 2
24 5 1385.32 10 9.07 2178 2 2
25 5 1376.72 10 9.24 2170 2 2
26 5 1307.00 10 9.28 2103 2 2
27 5 1376.92 10 9.18 2154 2 2
28 5 1311.64 10 9.15 2062 2 2
29 5 1327.52 10 9.28 2101 2 2
30 5 1317.00 10 9.20 2096 2 2
31 5 1320.08 10 9.20 2071 2 2
32 5 1339.32 10 9.20 2130 2 2
33 5 1360.68 10 9.10 2142 2 2
34 5 1358.88 10 9.20 2150 2 2
35 5 1378.80 10 9.21 2167 2 2
36 5 1409.36 10 9.11 2193 2 2
37 5 1337.12 10 9.20 2156 2 2
38 12 1383.12 104 9.15 2217 2 2
39 7 1377.72 24 9.24 2199 2 2
40 13 677.36 45 10.10 1266 2 2
41 13 94.64 45 10.89 455 2 2
42 8 0.04 165 11.03 307 2 2

Cycle 253 GMT 26/11/2022 14:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 24 10.97 450 2 2
2 10 1019.72 10 9.89 1710 2 2
3 10 1084.28 9 9.74 1813 2 2
4 10 1143.04 4 9.71 1892 2 2
5 5 1367.32 10 9.34 2184 2 2
6 5 1300.32 10 9.34 2109 2 2
7 5 1318.56 10 9.30 2094 2 2
8 5 1312.68 10 9.34 2123 2 2
9 5 1333.08 10 9.27 2111 2 2
10 5 1326.60 10 9.13 2139 2 2
11 5 1342.04 10 9.27 2107 2 2
12 5 1357.68 10 9.27 2171 2 2
13 5 1386.40 10 9.20 2188 2 2
14 5 1301.64 10 9.28 2127 2 2
15 5 1330.52 10 9.22 2123 2 2
16 5 1330.00 10 9.21 2142 2 2
17 5 1322.00 10 9.27 2134 2 2
18 5 1339.52 10 9.23 2155 2 2
19 5 1365.24 10 9.27 2183 2 2
20 5 1304.28 10 9.28 2119 2 2
21 5 1315.84 10 9.32 2125 2 2
22 5 1328.88 10 9.24 2091 2 2
23 5 1333.68 10 9.25 2159 2 2
24 5 1362.92 10 9.22 2137 2 2
25 5 1397.52 10 9.20 2196 2 2
26 5 1326.76 10 9.25 2156 2 2
27 5 1342.80 10 9.22 2152 2 2
28 5 1348.28 10 9.26 2158 2 2
29 5 1366.60 10 9.23 2175 2 2
30 5 1381.84 10 9.21 2168 2 2
31 5 1404.88 10 9.20 2196 2 2
32 5 1337.16 10 9.26 2149 2 2
33 5 1357.56 10 9.15 2215 2 2
34 5 1367.00 10 9.21 2220 2 2
35 5 1373.48 10 9.20 2145 2 2
36 5 1373.16 10 9.21 2208 2 2
37 12 1425.88 104 9.16 2275 2 2
38 7 1420.68 24 9.22 2259 2 2
39 13 708.24 45 10.08 1320 2 2
40 13 58.52 45 10.96 395 2 2
41 8 0.08 165 11.04 311 2 2

Cycle 252 GMT 17/11/2022 0: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 38 10.97 435 2 2
2 10 1034.48 6 9.85 1745 2 2
3 5 1383.88 10 9.34 2190 2 2
4 5 1378.92 10 9.29 2195 2 2
5 5 1361.64 10 9.26 2178 2 2
6 5 1340.92 10 9.21 2102 2 2
7 12 1359.64 5 9.33 2154 2 2
8 12 1997.56 104 8.56 3011 2 2
9 7 1991.64 24 8.65 3004 2 2
10 13 1264.24 45 9.47 2060 2 2
11 13 531.28 45 10.33 1076 2 2
12 13 42.20 45 10.99 368 2 2
13 8 0.00 165 11.04 307 2 2

Cycle 251 GMT 15/11/2022 2: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 39 10.97 437 2 2
2 10 1004.44 6 9.87 1740 2 2
3 5 1376.40 10 9.39 2157 2 2
4 5 1377.68 10 9.36 2159 2 2
5 5 1366.76 10 9.29 2189 2 2
6 5 1403.28 10 9.31 2250 2 2
7 5 1310.76 10 9.36 2114 2 2
8 5 1319.56 10 9.37 2136 2 2
9 5 1306.76 10 9.33 2136 2 2
10 5 1339.20 10 9.32 2179 2 2
11 5 1358.44 10 9.27 2197 2 2
12 5 1398.36 10 9.17 2195 2 2
13 5 1312.44 10 9.39 2112 2 2
14 5 1302.56 10 9.40 2115 2 2
15 5 1337.12 10 9.38 2136 2 2
16 5 1355.76 10 9.29 2178 2 2
17 5 1387.72 10 9.20 2219 2 2
18 5 1308.80 10 9.34 2134 2 2
19 5 1319.64 10 9.33 2092 2 2
20 5 1330.64 10 9.27 2134 2 2
21 5 1373.32 10 9.28 2191 2 2
22 5 1379.04 10 9.27 2223 2 2
23 5 1314.04 10 9.33 2129 2 2
24 5 1309.56 10 9.24 2129 2 2
25 5 1352.20 10 9.27 2195 2 2
26 5 1384.56 10 9.24 2199 2 2
27 5 1315.88 10 9.34 2113 2 2
28 5 1306.56 10 9.37 2122 2 2
29 5 1335.48 10 9.27 2116 2 2
30 5 1345.48 10 9.28 2156 2 2
31 5 1370.08 10 9.22 2229 2 2
32 5 1369.44 10 9.32 2160 2 2
33 5 1392.40 10 9.23 2228 2 2
34 5 1315.92 10 9.32 2104 2 2
35 12 1359.92 104 9.29 2176 2 2
36 7 1354.52 24 9.36 2167 2 2
37 13 777.64 45 10.02 1406 2 2
38 13 79.00 45 10.93 419 2 2
39 8 0.08 165 11.04 300 2 2

Cycle 250 GMT 5/11/2022 11:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 24 11.58 451 2 2
2 10 1006.24 10 10.79 1733 2 2
3 10 1053.80 7 10.72 1793 2 2
4 5 1310.68 10 10.32 2154 2 2
5 5 1401.96 10 10.24 2218 2 2
6 5 1307.04 10 10.32 2137 2 2
7 5 1365.24 10 10.27 2186 2 2
8 5 1327.92 10 10.18 2148 2 2
9 5 1306.92 10 10.06 2142 2 2
10 5 1313.76 10 10.10 2137 2 2
11 5 1305.96 10 10.09 2132 2 2
12 5 1340.64 10 10.00 2192 2 2
13 5 1342.08 10 9.97 2157 2 2
14 5 1342.40 10 9.99 2188 2 2
15 5 1326.28 10 9.96 2173 2 2
16 5 1380.68 10 10.04 2237 2 2
17 5 1357.80 10 10.08 2199 2 2
18 5 1366.00 10 10.10 2213 2 2
19 5 1359.88 10 10.09 2210 2 2
20 5 1373.68 10 10.11 2223 2 2
21 5 1362.24 10 10.03 2183 2 2
22 5 1370.76 10 9.97 2201 2 2
23 5 1378.44 10 10.02 2200 2 2
24 5 1404.12 10 9.93 2259 2 2
25 5 1309.92 10 9.97 2134 2 2
26 5 1375.92 10 9.83 2221 2 2
27 5 1367.64 10 9.86 2198 2 2
28 5 1363.28 10 9.77 2202 2 2
29 5 1369.56 10 9.87 2205 2 2
30 5 1371.80 10 9.82 2248 2 2
31 5 1361.04 10 9.78 2223 2 2
32 12 1452.20 104 9.49 2300 2 2
33 7 1446.76 25 9.44 2278 2 2
34 13 717.56 45 10.07 1337 2 2
35 13 64.80 45 10.94 404 2 2
36 8 0.08 165 11.03 302 2 2

Cycle 249 GMT 26/10/2022 20:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 24 12.30 459 2 2
2 10 1051.08 8 11.48 1810 2 2
3 10 1087.00 5 11.48 1883 2 2
4 10 1122.84 5 11.46 1916 2 2
5 5 1314.40 10 11.01 2148 2 2
6 5 1413.08 10 10.84 2259 2 2
7 5 1394.00 10 10.84 2246 2 2
8 5 1380.96 10 10.79 2226 2 2
9 5 1352.04 10 10.81 2209 2 2
10 5 1347.00 10 10.77 2173 2 2
11 5 1401.92 10 10.68 2237 2 2
12 5 1304.04 10 10.83 2121 2 2
13 5 1411.12 10 10.57 2255 2 2
14 5 1310.40 10 10.76 2135 2 2
15 5 1300.16 10 10.62 2118 2 2
16 5 1332.56 10 10.68 2119 2 2
17 5 1300.04 10 10.62 2097 2 2
18 5 1381.16 10 10.44 2231 2 2
19 5 1373.92 10 10.28 2221 2 2
20 5 1384.52 10 10.34 2246 2 2
21 5 1400.68 10 10.22 2248 2 2
22 5 1315.08 10 10.31 2165 2 2
23 5 1389.44 10 10.29 2193 2 2
24 5 1367.44 10 10.22 2207 2 2
25 5 1372.52 10 10.18 2208 2 2
26 5 1351.88 10 10.17 2190 2 2
27 5 1358.88 10 10.00 2216 2 2
28 5 1377.40 10 9.99 2211 2 2
29 5 1393.20 10 10.03 2229 2 2
30 5 1404.28 10 10.01 2279 2 2
31 5 1303.84 10 10.19 2125 2 2
32 5 1397.64 10 10.11 2207 2 2
33 12 1402.52 104 9.68 2232 2 2
34 7 1397.08 24 9.79 2232 2 2
35 13 665.16 45 10.63 1265 2 2
36 13 71.40 45 11.43 413 2 2
37 8 0.04 165 11.49 308 2 2

Cycle 248 GMT 17/10/2022 6:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 38 12.70 452 2 2
2 5 1317.12 10 10.84 2163 2 2
3 5 1301.72 10 10.83 2133 2 2
4 5 1316.48 10 10.70 2141 2 2
5 12 1289.88 5 10.88 2086 2 2
6 12 1996.24 104 8.79 3011 2 2
7 7 1990.24 24 9.08 3012 2 2
8 13 1237.12 45 10.28 2047 2 2
9 13 337.96 45 11.67 824 2 2
10 8 0.08 165 12.15 317 2 2

Cycle 247 GMT 15/10/2022 8: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 39 13.25 469 2 2
2 5 1371.16 10 11.09 2248 2 2
3 5 1329.08 10 10.97 2191 2 2
4 5 1309.00 10 10.95 2151 2 2
5 5 1340.04 10 10.71 2196 2 2
6 5 1335.96 10 10.72 2187 2 2
7 5 1339.08 10 10.68 2177 2 2
8 5 1360.00 10 10.51 2186 2 2
9 5 1333.36 10 10.47 2178 2 2
10 5 1323.00 10 10.48 2151 2 2
11 5 1333.92 10 10.40 2161 2 2
12 5 1319.84 10 10.35 2141 2 2
13 5 1342.56 10 10.30 2172 2 2
14 5 1349.96 10 10.23 2207 2 2
15 5 1370.96 10 10.18 2225 2 2
16 5 1315.32 10 10.31 2157 2 2
17 5 1308.32 10 10.20 2152 2 2
18 5 1350.28 10 10.15 2163 2 2
19 5 1339.84 10 10.09 2153 2 2
20 5 1368.80 10 9.94 2217 2 2
21 5 1356.44 10 9.93 2201 2 2
22 5 1376.84 10 9.79 2200 2 2
23 5 1301.88 10 9.98 2116 2 2
24 5 1389.44 10 9.71 2203 2 2
25 5 1335.92 10 9.79 2158 2 2
26 5 1362.28 10 9.60 2195 2 2
27 5 1373.12 10 9.37 2201 2 2
28 5 1377.60 10 9.23 2228 2 2
29 5 1309.84 10 9.48 2113 2 2
30 5 1310.32 10 9.36 2127 2 2
31 12 1354.76 104 8.93 2158 2 2
32 7 1349.68 24 10.01 2172 2 2
33 13 761.36 45 11.13 1400 2 2
34 13 71.68 45 12.54 430 2 2
35 8 -0.08 165 12.57 319 2 2

Cycle 246 GMT 5/10/2022 17:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 24 13.98 456 2 2
2 10 1010.96 8 12.96 1781 2 2
3 10 1064.40 4 12.96 1865 2 2
4 5 1322.40 10 11.98 2206 2 2
5 5 1321.48 10 11.68 2178 2 2
6 5 1374.60 10 11.45 2208 2 2
7 5 1328.72 10 11.43 2192 2 2
8 5 1316.32 10 11.33 2168 2 2
9 5 1403.40 10 11.09 2250 2 2
10 5 1386.80 10 11.03 2228 2 2
11 5 1369.16 10 10.87 2217 2 2
12 5 1357.12 10 10.89 2209 2 2
13 5 1360.88 10 10.81 2201 2 2
14 5 1362.92 10 10.79 2207 2 2
15 5 1358.72 10 10.66 2203 2 2
16 5 1363.56 10 10.49 2198 2 2
17 5 1342.92 10 10.53 2174 2 2
18 5 1347.68 10 10.34 2194 2 2
19 5 1353.48 10 10.28 2186 2 2
20 5 1381.40 10 10.20 2219 2 2
21 5 1394.72 10 10.10 2218 2 2
22 5 1305.60 10 10.26 2128 2 2
23 5 1319.28 10 10.16 2139 2 2
24 5 1303.76 10 10.17 2126 2 2
25 5 1380.24 10 9.95 2228 2 2
26 5 1310.36 10 10.14 2142 2 2
27 5 1325.52 10 10.09 2171 2 2
28 5 1334.04 10 9.97 2165 2 2
29 5 1369.64 10 9.88 2203 2 2
30 5 1377.44 10 9.95 2197 2 2
31 5 1384.28 10 9.71 2215 2 2
32 12 1428.44 104 9.48 2266 2 2
33 7 1423.16 24 10.64 2286 2 2
34 13 659.76 45 12.22 1268 2 2
35 13 57.96 45 13.20 425 2 2
36 8 0.08 165 13.13 331 2 2

Cycle 245 GMT 26/ 9/2022 3:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 24 14.24 462 2 2
2 10 1065.88 7 13.06 1862 2 2
3 10 1097.72 5 13.21 1905 2 2
4 5 1346.28 10 12.31 2224 2 2
5 5 1303.32 10 12.18 2177 2 2
6 5 1325.76 10 11.82 2182 2 2
7 5 1391.36 10 11.39 2276 2 2
8 5 1369.04 10 11.51 2230 2 2
9 5 1329.76 10 11.46 2162 2 2
10 5 1322.20 10 11.42 2171 2 2
11 5 1371.96 10 11.13 2211 2 2
12 5 1331.00 10 11.21 2165 2 2
13 5 1356.60 10 11.06 2199 2 2
14 5 1347.68 10 11.04 2224 2 2
15 5 1361.64 10 11.01 2217 2 2
16 5 1323.36 10 11.03 2154 2 2
17 5 1320.76 10 10.99 2164 2 2
18 5 1370.08 10 10.77 2174 2 2
19 5 1345.12 10 10.83 2187 2 2
20 5 1332.20 10 10.64 2165 2 2
21 5 1338.36 10 10.69 2171 2 2
22 5 1400.44 10 10.49 2265 2 2
23 5 1389.20 10 10.50 2223 2 2
24 5 1396.64 10 10.27 2271 2 2
25 5 1321.32 10 10.68 2160 2 2
26 5 1331.36 10 10.41 2178 2 2
27 5 1333.12 10 10.38 2165 2 2
28 5 1331.68 10 10.29 2156 2 2
29 5 1338.20 10 10.15 2157 2 2
30 12 1448.28 104 9.61 2290 2 2
31 7 1441.68 24 10.87 2307 2 2
32 13 565.48 45 12.86 1149 2 2
33 13 22.56 45 13.85 357 2 2
34 8 -0.04 165 13.75 323 2 2

Cycle 244 GMT 16/ 9/2022 12:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 38 14.25 481 2 2
2 5 1314.72 10 11.41 2137 2 2
3 5 1354.08 10 11.16 2206 2 2
4 12 1422.88 5 11.00 2316 2 2
5 12 1995.04 104 9.60 3022 2 2
6 7 1988.32 24 10.50 3034 2 2
7 13 775.36 45 12.83 1441 2 2
8 13 64.40 45 14.03 438 2 2
9 8 0.08 165 14.02 336 2 2

Cycle 243 GMT 14/ 9/2022 14:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 39 14.27 477 2 2
2 5 1330.84 10 11.49 2141 2 2
3 5 1383.08 10 11.21 2223 2 2
4 5 1383.72 10 10.98 2257 2 2
5 5 1355.56 10 10.98 2208 2 2
6 5 1336.80 10 10.90 2189 2 2
7 5 1324.04 10 10.83 2172 2 2
8 5 1356.16 10 10.73 2217 2 2
9 5 1377.68 10 10.53 2213 2 2
10 5 1381.84 10 10.40 2233 2 2
11 5 1403.68 10 10.38 2271 2 2
12 5 1328.80 10 10.56 2156 2 2
13 5 1346.04 10 10.31 2167 2 2
14 5 1355.28 10 10.16 2191 2 2
15 5 1401.44 10 9.99 2237 2 2
16 5 1333.16 10 10.20 2154 2 2
17 5 1361.24 10 10.01 2176 2 2
18 5 1384.84 10 9.68 2233 2 2
19 5 1328.40 10 9.95 2149 2 2
20 5 1389.80 10 9.77 2198 2 2
21 5 1341.36 10 9.84 2144 2 2
22 5 1347.44 10 9.48 2154 2 2
23 5 1304.36 10 9.83 2105 2 2
24 5 1314.52 10 9.55 2107 2 2
25 5 1344.12 10 9.28 2169 2 2
26 5 1384.72 10 9.14 2219 2 2
27 5 1358.16 10 9.23 2182 2 2
28 5 1322.00 10 9.38 2125 2 2
29 5 1378.08 10 9.06 2171 2 2
30 5 1340.68 10 9.22 2138 2 2
31 5 1375.96 10 8.77 2188 2 2
32 5 1358.72 10 8.71 2152 2 2
33 5 1311.12 10 9.14 2095 2 2
34 12 1482.84 104 8.68 2327 2 2
35 7 1478.16 24 10.63 2355 2 2
36 13 1047.88 45 12.16 1808 2 2
37 13 88.40 45 14.02 478 2 2
38 8 0.12 165 14.15 336 2 2

Cycle 242 GMT 5/ 9/2022 0:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 24 14.31 473 2 2
2 10 1057.24 7 12.98 1857 2 2
3 10 1129.48 4 12.89 1961 2 2
4 5 1307.88 10 12.14 2186 2 2
5 5 1305.40 10 11.78 2199 2 2
6 5 1315.92 10 11.44 2176 2 2
7 5 1338.76 10 11.29 2209 2 2
8 5 1308.80 10 11.26 2158 2 2
9 5 1344.76 10 11.00 2208 2 2
10 5 1330.32 10 10.91 2168 2 2
11 5 1305.12 10 10.90 2159 2 2
12 5 1319.84 10 10.68 2131 2 2
13 5 1300.60 10 10.76 2121 2 2
14 5 1373.72 10 10.38 2228 2 2
15 5 1356.80 10 10.40 2209 2 2
16 5 1342.92 10 10.47 2187 2 2
17 5 1331.12 10 10.26 2185 2 2
18 5 1322.20 10 10.24 2158 2 2
19 5 1327.32 10 10.17 2175 2 2
20 5 1322.72 10 10.18 2163 2 2
21 5 1348.80 10 9.94 2210 2 2
22 5 1408.08 10 9.72 2283 2 2
23 5 1355.00 10 10.03 2200 2 2
24 5 1403.16 10 9.82 2234 2 2
25 5 1337.88 10 9.88 2164 2 2
26 5 1415.84 10 9.67 2279 2 2
27 5 1389.24 10 9.64 2259 2 2
28 5 1326.20 10 9.90 2161 2 2
29 5 1344.24 10 9.53 2178 2 2
30 5 1318.92 10 9.55 2160 2 2
31 5 1347.84 10 9.41 2157 2 2
32 5 1333.36 10 9.36 2179 2 2
33 12 1494.04 104 9.10 2366 2 2
34 7 1488.60 24 10.83 2380 2 2
35 13 744.44 45 13.03 1399 2 2
36 13 48.72 45 14.14 412 2 2
37 8 0.04 165 14.22 337 2 2

Cycle 241 GMT 26/ 8/2022 9:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 24 14.35 467 2 2
2 10 1049.28 8 13.07 1827 2 2
3 5 1357.48 10 12.34 2241 2 2
4 5 1369.60 10 11.95 2232 2 2
5 5 1316.28 10 11.93 2170 2 2
6 5 1386.96 10 11.53 2234 2 2
7 5 1373.88 10 11.53 2256 2 2
8 5 1347.92 10 11.45 2215 2 2
9 5 1301.52 10 11.47 2144 2 2
10 5 1306.56 10 11.32 2147 2 2
11 5 1348.84 10 10.99 2183 2 2
12 5 1311.56 10 11.07 2151 2 2
13 5 1307.84 10 10.94 2151 2 2
14 5 1326.80 10 10.86 2179 2 2
15 5 1312.36 10 10.80 2158 2 2
16 5 1329.08 10 10.82 2180 2 2
17 5 1346.04 10 10.65 2195 2 2
18 5 1370.80 10 10.61 2224 2 2
19 5 1351.28 10 10.55 2210 2 2
20 5 1358.16 10 10.37 2205 2 2
21 5 1406.16 10 10.37 2278 2 2
22 5 1329.40 10 10.61 2170 2 2
23 5 1342.08 10 10.52 2171 2 2
24 5 1353.04 10 10.39 2211 2 2
25 5 1386.88 10 10.19 2241 2 2
26 5 1307.40 10 10.45 2142 2 2
27 5 1391.32 10 9.95 2263 2 2
28 5 1329.60 10 10.10 2177 2 2
29 5 1360.20 10 9.97 2220 2 2
30 5 1378.76 10 9.87 2230 2 2
31 5 1310.40 10 10.07 2128 2 2
32 12 1476.52 104 9.58 2354 2 2
33 7 1470.68 24 11.00 2367 2 2
34 13 579.40 45 13.34 1194 2 2
35 13 19.52 45 14.21 371 2 2
36 8 -0.12 165 14.23 344 2 2

Cycle 240 GMT 16/ 8/2022 19: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 38 14.32 463 2 2
2 5 1372.96 10 11.57 2264 2 2
3 5 1382.80 10 11.36 2242 2 2
4 12 1424.44 5 11.10 2321 2 2
5 12 1995.12 104 9.89 3050 2 2
6 7 1988.36 24 10.67 3039 2 2
7 13 889.68 45 12.99 1602 2 2
8 13 86.60 45 14.09 488 2 2
9 8 0.04 165 14.26 344 2 2

Cycle 239 GMT 14/ 8/2022 21:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 39 14.30 479 2 2
2 5 1344.60 10 11.63 2222 2 2
3 5 1364.20 10 11.45 2224 2 2
4 5 1338.48 10 11.41 2204 2 2
5 5 1343.64 10 11.26 2224 2 2
6 5 1351.24 10 11.15 2214 2 2
7 5 1371.56 10 11.05 2256 2 2
8 5 1380.12 10 10.86 2237 2 2
9 5 1396.84 10 10.80 2256 2 2
10 5 1305.68 10 11.05 2157 2 2
11 5 1313.72 10 10.88 2167 2 2
12 5 1309.12 10 10.78 2159 2 2
13 5 1334.20 10 10.56 2174 2 2
14 5 1344.76 10 10.45 2173 2 2
15 5 1367.24 10 10.35 2230 2 2
16 5 1386.20 10 10.30 2249 2 2
17 5 1311.00 10 10.47 2144 2 2
18 5 1320.76 10 10.24 2160 2 2
19 5 1373.72 10 10.03 2215 2 2
20 5 1389.32 10 10.00 2242 2 2
21 5 1323.20 10 10.13 2159 2 2
22 5 1378.80 10 9.83 2226 2 2
23 5 1312.40 10 10.10 2135 2 2
24 5 1354.40 10 9.80 2178 2 2
25 5 1411.60 10 9.56 2248 2 2
26 5 1365.36 10 9.82 2190 2 2
27 5 1305.36 10 9.87 2131 2 2
28 5 1364.32 10 9.64 2188 2 2
29 5 1335.44 10 9.68 2173 2 2
30 5 1399.60 10 9.10 2218 2 2
31 5 1365.92 10 9.52 2184 2 2
32 5 1329.48 10 9.56 2135 2 2
33 5 1378.60 10 9.04 2174 2 2
34 12 1439.84 104 9.27 2282 2 2
35 7 1433.92 24 10.84 2299 2 2
36 13 708.44 45 13.14 1347 2 2
37 13 36.68 45 14.18 392 2 2
38 8 0.08 165 14.28 337 2 2

Cycle 238 GMT 5/ 8/2022 7: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 24 14.33 476 2 2
2 10 1001.16 8 13.09 1758 2 2
3 5 1307.52 10 12.32 2190 2 2
4 5 1339.40 10 11.76 2205 2 2
5 5 1314.56 10 11.77 2187 2 2
6 5 1397.16 10 11.36 2298 2 2
7 5 1301.00 10 11.71 2164 2 2
8 5 1356.52 10 11.18 2222 2 2
9 5 1349.00 10 11.19 2218 2 2
10 5 1364.20 10 10.98 2235 2 2
11 5 1371.96 10 10.94 2231 2 2
12 5 1414.44 10 10.80 2287 2 2
13 5 1317.92 10 11.14 2164 2 2
14 5 1336.32 10 10.97 2179 2 2
15 5 1327.12 10 10.86 2160 2 2
16 5 1352.20 10 10.73 2199 2 2
17 5 1370.60 10 10.65 2225 2 2
18 5 1379.80 10 10.61 2230 2 2
19 5 1391.52 10 10.42 2263 2 2
20 5 1409.76 10 10.21 2272 2 2
21 5 1335.68 10 10.67 2175 2 2
22 5 1350.88 10 10.31 2202 2 2
23 5 1360.52 10 10.26 2218 2 2
24 5 1390.60 10 10.08 2234 2 2
25 5 1306.88 10 10.31 2142 2 2
26 5 1355.08 10 10.03 2194 2 2
27 5 1394.60 10 9.92 2258 2 2
28 5 1336.20 10 9.93 2166 2 2
29 5 1382.72 10 9.86 2226 2 2
30 5 1326.08 10 9.86 2164 2 2
31 5 1361.80 10 9.68 2206 2 2
32 5 1300.80 10 9.80 2110 2 2
33 5 1348.28 10 9.61 2157 2 2
34 5 1321.72 10 9.70 2136 2 2
35 12 1478.92 104 9.36 2349 2 2
36 7 1473.40 24 10.93 2373 2 2
37 13 604.56 45 13.35 1218 2 2
38 13 46.76 45 14.16 413 2 2
39 8 0.04 165 14.29 342 2 2

Cycle 237 GMT 26/ 7/2022 16:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 24 14.31 488 2 2
2 10 1002.68 8 13.21 1763 2 2
3 10 1038.76 5 13.37 1832 2 2
4 5 1317.16 10 12.26 2197 2 2
5 5 1328.64 10 11.97 2197 2 2
6 5 1361.20 10 11.53 2248 2 2
7 5 1369.48 10 11.54 2263 2 2
8 5 1349.24 10 11.48 2228 2 2
9 5 1338.88 10 11.42 2194 2 2
10 5 1331.00 10 11.37 2171 2 2
11 5 1346.52 10 11.20 2215 2 2
12 5 1336.44 10 11.16 2198 2 2
13 5 1330.40 10 11.02 2184 2 2
14 5 1360.00 10 10.89 2235 2 2
15 5 1382.04 10 10.84 2261 2 2
16 5 1384.40 10 10.91 2274 2 2
17 5 1410.28 10 10.66 2272 2 2
18 5 1335.16 10 11.15 2199 2 2
19 5 1311.48 10 10.95 2156 2 2
20 5 1330.08 10 10.74 2160 2 2
21 5 1337.96 10 10.73 2186 2 2
22 5 1348.20 10 10.66 2221 2 2
23 5 1361.40 10 10.49 2226 2 2
24 5 1361.08 10 10.55 2218 2 2
25 5 1374.52 10 10.43 2232 2 2
26 5 1412.16 10 10.13 2286 2 2
27 5 1325.24 10 10.48 2175 2 2
28 5 1345.32 10 10.38 2179 2 2
29 5 1367.16 10 10.21 2207 2 2
30 5 1304.84 10 10.40 2171 2 2
31 5 1349.24 10 10.13 2194 2 2
32 5 1377.80 10 9.89 2247 2 2
33 5 1335.80 10 10.24 2183 2 2
34 12 1357.48 104 10.07 2193 2 2
35 7 1351.08 24 11.08 2200 2 2
36 13 323.28 45 13.75 839 2 2
37 8 0.00 165 14.26 344 2 2

Cycle 236 GMT 17/ 7/2022 2:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 38 14.29 480 2 2
2 5 1377.40 10 11.55 2216 2 2
3 5 1305.40 10 11.71 2154 2 2
4 12 1318.16 5 11.28 2153 2 2
5 12 1996.08 104 9.95 3064 2 2
6 7 1989.16 25 10.71 3046 2 2
7 13 726.76 45 13.27 1395 2 2
8 13 48.72 45 14.16 429 2 2
9 8 0.00 165 14.30 347 2 2

Cycle 235 GMT 15/ 7/2022 4: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 39 14.28 480 2 2
2 5 1380.72 10 11.70 2281 2 2
3 5 1338.84 10 11.74 2200 2 2
4 5 1366.44 10 11.27 2234 2 2
5 5 1315.00 10 11.39 2177 2 2
6 5 1361.08 10 11.04 2228 2 2
7 5 1351.32 10 11.06 2211 2 2
8 5 1318.00 10 10.95 2178 2 2
9 5 1322.96 10 10.90 2168 2 2
10 5 1357.72 10 10.69 2221 2 2
11 5 1357.88 10 10.76 2233 2 2
12 5 1390.44 10 10.61 2259 2 2
13 5 1308.32 10 10.85 2164 2 2
14 5 1403.12 10 10.31 2255 2 2
15 5 1300.12 10 10.70 2143 2 2
16 5 1316.52 10 10.45 2152 2 2
17 5 1320.28 10 10.45 2145 2 2
18 5 1366.56 10 10.21 2230 2 2
19 5 1387.40 10 9.93 2229 2 2
20 5 1317.80 10 10.25 2163 2 2
21 5 1348.40 10 9.97 2179 2 2
22 5 1373.96 10 9.84 2195 2 2
23 5 1313.52 10 9.90 2129 2 2
24 5 1339.64 10 9.86 2156 2 2
25 5 1367.16 10 9.45 2212 2 2
26 5 1306.80 10 9.73 2143 2 2
27 5 1340.12 10 9.39 2159 2 2
28 5 1301.84 10 9.59 2132 2 2
29 5 1340.32 10 9.37 2149 2 2
30 5 1393.28 10 9.04 2222 2 2
31 5 1372.36 10 9.22 2182 2 2
32 12 1408.32 104 9.45 2253 2 2
33 7 1402.80 24 10.95 2271 2 2
34 13 530.76 45 13.48 1119 2 2
35 13 40.16 45 14.16 407 2 2
36 8 0.00 165 14.28 344 2 2

Cycle 234 GMT 5/ 7/2022 13:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 24 14.29 480 2 2
2 10 1072.24 8 13.08 1865 2 2
3 5 1370.80 10 12.14 2257 2 2
4 5 1306.80 10 12.02 2183 2 2
5 5 1306.28 10 11.63 2152 2 2
6 5 1316.96 10 11.44 2176 2 2
7 5 1320.16 10 11.37 2168 2 2
8 5 1382.28 10 11.09 2265 2 2
9 5 1401.32 10 11.01 2267 2 2
10 5 1318.52 10 11.38 2167 2 2
11 5 1406.40 10 10.82 2274 2 2
12 5 1310.56 10 11.32 2156 2 2
13 5 1317.32 10 11.14 2169 2 2
14 5 1322.20 10 10.99 2172 2 2
15 5 1310.80 10 10.93 2148 2 2
16 5 1316.04 10 10.93 2147 2 2
17 5 1332.24 10 10.83 2186 2 2
18 5 1315.12 10 10.66 2151 2 2
19 5 1313.44 10 10.78 2160 2 2
20 5 1349.84 10 10.47 2183 2 2
21 5 1363.88 10 10.36 2217 2 2
22 5 1402.64 10 10.22 2247 2 2
23 5 1328.56 10 10.53 2154 2 2
24 5 1324.64 10 10.40 2178 2 2
25 5 1378.08 10 10.13 2210 2 2
26 5 1382.20 10 9.94 2237 2 2
27 5 1344.12 10 10.23 2195 2 2
28 5 1369.24 10 9.99 2230 2 2
29 5 1305.68 10 10.03 2156 2 2
30 5 1323.56 10 9.98 2173 2 2
31 5 1412.24 10 9.52 2272 2 2
32 5 1367.08 10 9.76 2204 2 2
33 12 1497.16 104 9.53 2381 2 2
34 7 1491.36 24 10.97 2387 2 2
35 13 485.96 45 13.58 1056 2 2
36 13 28.60 45 14.18 392 2 2
37 8 0.12 165 14.28 343 2 2

Cycle 233 GMT 25/ 6/2022 22:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 24 14.30 471 2 2
2 10 1061.80 7 13.13 1854 2 2
3 10 1108.08 4 13.24 1922 2 2
4 5 1382.88 10 12.18 2258 2 2
5 5 1326.44 10 12.06 2209 2 2
6 5 1362.52 10 11.66 2237 2 2
7 5 1357.40 10 11.67 2258 2 2
8 5 1377.52 10 11.54 2262 2 2
9 5 1385.20 10 11.41 2269 2 2
10 5 1358.12 10 11.39 2233 2 2
11 5 1347.48 10 11.35 2220 2 2
12 5 1300.72 10 11.34 2158 2 2
13 5 1393.96 10 11.05 2258 2 2
14 5 1379.16 10 11.08 2268 2 2
15 5 1383.68 10 11.02 2270 2 2
16 5 1402.00 10 10.94 2284 2 2
17 5 1312.84 10 11.30 2174 2 2
18 5 1381.04 10 10.73 2247 2 2
19 5 1377.84 10 10.84 2253 2 2
20 5 1391.64 10 10.83 2279 2 2
21 5 1312.24 10 11.20 2186 2 2
22 5 1302.40 10 10.88 2154 2 2
23 5 1305.36 10 10.84 2144 2 2
24 5 1376.92 10 10.68 2196 2 2
25 5 1394.96 10 10.52 2264 2 2
26 5 1306.84 10 10.93 2158 2 2
27 5 1381.00 10 10.38 2254 2 2
28 5 1419.04 10 10.43 2302 2 2
29 5 1335.40 10 10.59 2195 2 2
30 5 1334.80 10 10.58 2185 2 2
31 5 1392.80 10 10.31 2256 2 2
32 5 1325.60 10 10.55 2176 2 2
33 12 1333.84 104 10.29 2168 2 2
34 7 1327.32 24 11.11 2183 2 2
35 13 405.44 45 13.65 959 2 2
36 13 37.00 45 14.17 407 2 2
37 8 0.00 165 14.27 346 2 2

Cycle 232 GMT 16/ 6/2022 8:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 38 14.29 475 2 2
2 5 1315.36 10 11.75 2125 2 2
3 5 1365.92 10 11.50 2242 2 2
4 12 1393.96 5 11.28 2229 2 2
5 12 1996.44 104 10.03 3050 2 2
6 7 1989.88 24 10.78 3060 2 2
7 13 736.36 45 13.31 1401 2 2
8 13 47.60 45 14.16 424 2 2
9 8 -0.04 165 14.27 347 2 2

Cycle 231 GMT 14/ 6/2022 11: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 39 14.23 480 2 2
2 5 1351.36 10 11.75 2252 2 2
3 5 1323.36 10 11.83 2200 2 2
4 5 1349.56 10 11.43 2226 2 2
5 5 1311.84 10 11.38 2157 2 2
6 5 1349.92 10 11.10 2228 2 2
7 5 1334.28 10 11.06 2191 2 2
8 5 1329.68 10 11.08 2170 2 2
9 5 1306.16 10 11.05 2160 2 2
10 5 1361.36 10 10.79 2228 2 2
11 5 1361.88 10 10.75 2216 2 2
12 5 1359.96 10 10.63 2215 2 2
13 5 1374.32 10 10.60 2215 2 2
14 5 1382.48 10 10.53 2250 2 2
15 5 1388.60 10 10.32 2245 2 2
16 5 1323.00 10 10.54 2165 2 2
17 5 1351.28 10 10.46 2215 2 2
18 5 1383.44 10 10.22 2266 2 2
19 5 1310.92 10 10.43 2160 2 2
20 5 1334.44 10 10.22 2202 2 2
21 5 1355.52 10 10.05 2235 2 2
22 5 1323.00 10 10.23 2166 2 2
23 5 1351.48 10 9.86 2183 2 2
24 5 1323.92 10 9.94 2163 2 2
25 5 1380.32 10 9.57 2246 2 2
26 5 1307.20 10 9.85 2153 2 2
27 5 1338.40 10 9.67 2181 2 2
28 5 1412.60 10 9.36 2260 2 2
29 5 1405.24 10 9.48 2264 2 2
30 5 1354.32 10 9.58 2208 2 2
31 5 1383.88 10 9.02 2225 2 2
32 12 1454.24 104 9.51 2317 2 2
33 7 1448.92 24 10.90 2338 2 2
34 13 722.36 45 13.26 1392 2 2
35 13 43.00 45 14.16 411 2 2
36 8 0.04 165 14.27 340 2 2

Cycle 230 GMT 4/ 6/2022 20:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 24 14.23 483 2 2
2 10 1002.36 8 13.14 1773 2 2
3 10 1051.96 4 13.27 1842 2 2
4 5 1304.64 10 12.27 2153 2 2
5 5 1323.56 10 11.85 2187 2 2
6 5 1349.88 10 11.51 2216 2 2
7 5 1372.92 10 11.35 2243 2 2
8 5 1349.64 10 11.27 2211 2 2
9 5 1312.68 10 11.38 2151 2 2
10 5 1373.20 10 11.07 2203 2 2
11 5 1344.88 10 11.12 2203 2 2
12 5 1302.68 10 11.13 2155 2 2
13 5 1303.44 10 11.11 2151 2 2
14 5 1301.16 10 11.04 2119 2 2
15 5 1402.16 10 10.77 2282 2 2
16 5 1308.08 10 11.06 2177 2 2
17 5 1358.64 10 10.71 2217 2 2
18 5 1363.00 10 10.58 2223 2 2
19 5 1363.20 10 10.54 2227 2 2
20 5 1387.80 10 10.53 2254 2 2
21 5 1394.16 10 10.35 2244 2 2
22 5 1314.64 10 10.55 2156 2 2
23 5 1382.84 10 10.18 2231 2 2
24 5 1307.48 10 10.37 2152 2 2
25 5 1310.68 10 10.33 2115 2 2
26 5 1313.36 10 10.15 2163 2 2
27 5 1328.92 10 10.04 2170 2 2
28 5 1368.04 10 9.90 2220 2 2
29 5 1344.16 10 9.99 2190 2 2
30 5 1368.48 10 9.90 2181 2 2
31 5 1339.40 10 9.82 2161 2 2
32 12 1475.24 104 9.68 2364 2 2
33 7 1469.40 24 11.01 2359 2 2
34 13 705.04 45 13.33 1361 2 2
35 13 36.08 45 14.17 392 2 2
36 8 0.04 165 14.26 341 2 2

Cycle 229 GMT 26/ 5/2022 6: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 24 14.23 477 2 2
2 10 1046.48 6 13.18 1840 2 2
3 10 1081.32 5 13.37 1887 2 2
4 5 1307.68 10 12.36 2182 2 2
5 5 1330.64 10 11.94 2207 2 2
6 5 1358.08 10 11.65 2245 2 2
7 5 1311.40 10 11.69 2175 2 2
8 5 1302.88 10 11.68 2161 2 2
9 5 1340.80 10 11.36 2215 2 2
10 5 1335.96 10 11.40 2204 2 2
11 5 1302.24 10 11.43 2161 2 2
12 5 1364.76 10 11.20 2216 2 2
13 5 1378.84 10 11.20 2254 2 2
14 5 1358.72 10 11.14 2215 2 2
15 5 1354.72 10 11.11 2223 2 2
16 5 1346.48 10 11.14 2197 2 2
17 5 1337.12 10 11.07 2203 2 2
18 5 1330.44 10 11.09 2191 2 2
19 5 1340.12 10 11.07 2182 2 2
20 5 1356.96 10 10.98 2219 2 2
21 5 1358.88 10 10.80 2200 2 2
22 5 1373.48 10 10.86 2250 2 2
23 5 1367.04 10 10.79 2251 2 2
24 5 1387.56 10 10.81 2243 2 2
25 5 1400.20 10 10.63 2272 2 2
26 5 1399.76 10 10.65 2275 2 2
27 5 1307.32 10 10.97 2148 2 2
28 5 1401.60 10 10.47 2258 2 2
29 5 1319.92 10 10.69 2169 2 2
30 5 1309.12 10 10.65 2143 2 2
31 5 1342.64 10 10.51 2198 2 2
32 12 1354.76 104 10.30 2194 2 2
33 7 1348.60 24 11.15 2207 2 2
34 13 276.68 45 13.84 769 2 2
35 8 -0.16 165 14.24 340 2 2

Cycle 228 GMT 16/ 5/2022 15:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 38 14.23 475 2 2
2 5 1300.88 10 11.88 2116 2 2
3 5 1330.96 10 11.52 2200 2 2
4 12 1290.84 5 11.60 2141 2 2
5 12 1993.44 104 10.13 3054 2 2
6 7 1986.16 24 10.79 3058 2 2
7 13 717.08 45 13.35 1375 2 2
8 13 49.68 45 14.15 424 2 2
9 8 0.04 165 14.25 344 2 2

Cycle 227 GMT 14/ 5/2022 17:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 39 14.21 470 2 2
2 5 1337.60 10 11.88 2160 2 2
3 5 1385.00 10 11.61 2227 2 2
4 5 1373.40 10 11.60 2249 2 2
5 5 1334.80 10 11.45 2200 2 2
6 5 1309.44 10 11.40 2172 2 2
7 5 1383.64 10 11.16 2249 2 2
8 5 1360.76 10 11.21 2242 2 2
9 5 1332.36 10 11.21 2207 2 2
10 5 1313.80 10 11.15 2162 2 2
11 5 1354.48 10 10.88 2210 2 2
12 5 1352.96 10 10.95 2231 2 2
13 5 1320.76 10 10.90 2193 2 2
14 5 1335.88 10 10.90 2193 2 2
15 5 1355.36 10 10.78 2235 2 2
16 5 1357.20 10 10.74 2221 2 2
17 5 1341.00 10 10.72 2179 2 2
18 5 1301.52 10 10.51 2154 2 2
19 5 1373.56 10 10.34 2215 2 2
20 5 1380.84 10 10.38 2257 2 2
21 5 1327.16 10 10.48 2152 2 2
22 5 1327.68 10 10.24 2164 2 2
23 5 1328.72 10 10.18 2142 2 2
24 5 1339.24 10 10.16 2149 2 2
25 5 1361.68 10 9.95 2196 2 2
26 5 1303.52 10 10.05 2124 2 2
27 5 1323.00 10 9.89 2148 2 2
28 5 1372.96 10 9.77 2215 2 2
29 12 1432.52 104 9.84 2303 2 2
30 7 1426.84 25 10.95 2315 2 2
31 13 510.08 45 13.55 1097 2 2
32 8 0.00 165 14.23 344 2 2

Cycle 226 GMT 5/ 5/2022 3:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 24 14.23 463 2 2
2 10 1002.24 7 13.15 1760 2 2
3 10 1031.80 4 13.45 1818 2 2
4 5 1349.52 10 11.99 2229 2 2
5 5 1300.96 10 11.75 2156 2 2
6 5 1363.32 10 11.47 2240 2 2
7 5 1351.00 10 11.30 2209 2 2
8 5 1367.48 10 11.13 2232 2 2
9 5 1326.24 10 11.32 2171 2 2
10 5 1391.76 10 11.08 2248 2 2
11 5 1362.52 10 11.09 2223 2 2
12 5 1325.76 10 11.02 2171 2 2
13 5 1375.80 10 10.73 2241 2 2
14 5 1383.92 10 10.81 2237 2 2
15 5 1395.88 10 10.71 2257 2 2
16 5 1315.08 10 11.02 2164 2 2
17 5 1375.16 10 10.72 2246 2 2
18 5 1395.24 10 10.40 2243 2 2
19 5 1309.08 10 10.84 2147 2 2
20 5 1305.56 10 10.59 2139 2 2
21 5 1306.56 10 10.45 2122 2 2
22 5 1381.92 10 10.46 2199 2 2
23 5 1305.80 10 10.50 2130 2 2
24 5 1367.68 10 10.01 2213 2 2
25 5 1376.68 10 10.10 2229 2 2
26 5 1374.16 10 9.95 2227 2 2
27 5 1311.60 10 10.25 2165 2 2
28 5 1301.80 10 10.00 2124 2 2
29 12 1421.20 104 9.91 2280 2 2
30 7 1415.04 25 11.01 2289 2 2
31 13 505.24 45 13.58 1088 2 2
32 8 0.24 165 14.24 338 2 2

Cycle 225 GMT 25/ 4/2022 13: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 24 14.21 476 2 2
2 10 1072.48 8 13.18 1869 2 2
3 5 1344.04 10 12.30 2238 2 2
4 5 1312.96 10 12.00 2176 2 2
5 5 1346.36 10 11.66 2164 2 2
6 5 1386.40 10 11.55 2226 2 2
7 5 1343.72 10 11.53 2201 2 2
8 5 1385.56 10 11.29 2277 2 2
9 5 1361.24 10 11.41 2228 2 2
10 5 1359.52 10 11.50 2227 2 2
11 5 1326.32 10 11.48 2185 2 2
12 5 1305.32 10 11.49 2144 2 2
13 5 1329.16 10 11.11 2193 2 2
14 5 1328.16 10 11.23 2195 2 2
15 5 1316.40 10 11.29 2191 2 2
16 5 1395.60 10 11.05 2266 2 2
17 5 1392.24 10 11.04 2271 2 2
18 5 1364.24 10 11.12 2231 2 2
19 5 1311.00 10 11.15 2174 2 2
20 5 1333.68 10 10.94 2195 2 2
21 5 1358.32 10 10.70 2218 2 2
22 5 1318.12 10 10.82 2163 2 2
23 5 1370.64 10 10.67 2248 2 2
24 5 1338.48 10 10.66 2195 2 2
25 5 1371.52 10 10.45 2247 2 2
26 5 1395.44 10 10.34 2271 2 2
27 12 1395.56 104 10.27 2254 2 2
28 7 1388.92 24 11.21 2260 2 2
29 13 313.40 45 13.81 822 2 2
30 13 26.24 45 14.15 384 2 2
31 8 0.12 165 14.23 340 2 2

Cycle 224 GMT 15/ 4/2022 22:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 38 14.20 480 2 2
2 5 1304.44 10 11.88 2166 2 2
3 5 1353.76 10 11.62 2235 2 2
4 12 1305.64 5 11.78 2166 2 2
5 12 1994.12 104 10.31 3046 2 2
6 7 1986.76 24 10.84 3053 2 2
7 13 814.84 45 13.25 1506 2 2
8 13 50.12 45 14.13 432 2 2
9 8 -0.04 165 14.22 344 2 2

Cycle 223 GMT 14/ 4/2022 0:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 39 14.19 484 2 2
2 5 1313.24 10 11.77 2126 2 2
3 5 1360.20 10 11.57 2243 2 2
4 5 1327.56 10 11.60 2217 2 2
5 5 1332.84 10 11.36 2193 2 2
6 5 1364.04 10 11.18 2239 2 2
7 5 1332.64 10 11.42 2207 2 2
8 5 1372.64 10 11.21 2255 2 2
9 5 1315.52 10 11.25 2177 2 2
10 5 1374.68 10 10.98 2262 2 2
11 5 1346.64 10 11.08 2202 2 2
12 5 1327.68 10 10.99 2194 2 2
13 5 1366.20 10 10.80 2253 2 2
14 5 1379.76 10 10.75 2250 2 2
15 5 1381.80 10 10.71 2249 2 2
16 5 1357.32 10 10.65 2217 2 2
17 5 1317.20 10 10.64 2172 2 2
18 5 1379.16 10 10.38 2216 2 2
19 5 1367.72 10 10.41 2225 2 2
20 5 1352.84 10 10.40 2177 2 2
21 5 1345.52 10 10.29 2163 2 2
22 5 1335.88 10 10.12 2164 2 2
23 5 1325.88 10 10.19 2171 2 2
24 5 1325.04 10 10.06 2175 2 2
25 5 1346.32 10 9.85 2176 2 2
26 12 1458.88 104 9.89 2334 2 2
27 7 1453.08 24 11.13 2342 2 2
28 13 543.24 45 13.53 1144 2 2
29 8 0.20 165 14.23 341 2 2

Cycle 222 GMT 4/ 4/2022 10: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 24 14.14 486 2 2
2 10 1027.56 10 13.16 1801 2 2
3 5 1400.76 10 12.05 2300 2 2
4 5 1359.48 10 11.97 2255 2 2
5 5 1326.28 10 11.89 2200 2 2
6 5 1303.20 10 11.73 2163 2 2
7 5 1392.60 10 11.48 2301 2 2
8 5 1304.24 10 11.88 2163 2 2
9 5 1395.72 10 11.36 2304 2 2
10 5 1307.12 10 11.81 2168 2 2
11 5 1391.88 10 11.38 2237 2 2
12 5 1384.32 10 11.32 2277 2 2
13 5 1400.12 10 11.34 2292 2 2
14 5 1393.40 10 11.27 2264 2 2
15 5 1400.76 10 11.25 2286 2 2
16 5 1408.52 10 11.19 2293 2 2
17 5 1304.56 10 11.65 2156 2 2
18 5 1322.80 10 11.45 2180 2 2
19 5 1301.96 10 11.43 2156 2 2
20 5 1413.44 10 11.16 2288 2 2
21 5 1322.44 10 11.61 2183 2 2
22 5 1378.88 10 11.16 2253 2 2
23 5 1379.68 10 11.20 2273 2 2
24 5 1392.40 10 11.25 2266 2 2
25 5 1404.28 10 11.07 2286 2 2
26 5 1317.28 10 11.59 2155 2 2
27 5 1300.28 10 11.31 2161 2 2
28 5 1381.40 10 11.06 2255 2 2
29 5 1382.88 10 11.13 2264 2 2
30 5 1389.68 10 11.12 2249 2 2
31 5 1418.20 10 11.09 2315 2 2
32 12 1419.56 104 10.57 2294 2 2
33 7 1413.04 24 11.17 2295 2 2
34 13 331.72 45 13.75 845 2 2
35 13 26.40 45 14.13 389 2 2
36 8 0.08 165 14.20 345 2 2

Cycle 221 GMT 25/ 3/2022 19:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 24 14.16 473 2 2
2 10 1006.04 8 13.16 1757 2 2
3 10 1060.80 5 13.37 1848 2 2
4 5 1307.92 10 12.02 2149 2 2
5 5 1307.96 10 11.77 2173 2 2
6 5 1391.12 10 11.56 2290 2 2
7 5 1364.68 10 11.58 2241 2 2
8 5 1375.96 10 11.58 2222 2 2
9 5 1364.96 10 11.54 2251 2 2
10 5 1348.84 10 11.59 2200 2 2
11 5 1320.28 10 11.56 2190 2 2
12 5 1379.96 10 11.36 2251 2 2
13 5 1392.04 10 11.36 2297 2 2
14 5 1301.04 10 11.68 2164 2 2
15 5 1404.12 10 11.27 2305 2 2
16 5 1310.52 10 11.62 2155 2 2
17 5 1362.20 10 11.29 2249 2 2
18 5 1360.20 10 11.27 2228 2 2
19 5 1333.80 10 11.31 2209 2 2
20 5 1310.24 10 11.33 2148 2 2
21 5 1400.56 10 11.11 2248 2 2
22 5 1392.56 10 11.16 2263 2 2
23 5 1394.28 10 11.14 2302 2 2
24 5 1388.52 10 11.10 2273 2 2
25 5 1377.72 10 11.22 2246 2 2
26 5 1372.24 10 11.09 2254 2 2
27 5 1391.48 10 10.99 2263 2 2
28 5 1390.56 10 11.04 2278 2 2
29 5 1390.04 10 11.11 2246 2 2
30 5 1390.00 10 10.90 2265 2 2
31 12 1394.44 104 10.59 2256 2 2
32 7 1387.96 24 11.21 2250 2 2
33 13 170.88 45 13.95 596 2 2
34 8 0.08 165 14.19 345 2 2

Cycle 220 GMT 16/ 3/2022 5:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 38 14.13 489 2 2
2 5 1344.68 10 11.72 2217 2 2
3 5 1318.16 10 11.89 2187 2 2
4 5 1325.60 10 11.61 2199 2 2
5 12 1298.36 5 11.82 2158 2 2
6 12 1996.96 104 10.20 3037 2 2
7 7 1990.28 24 10.81 3067 2 2
8 13 702.52 45 13.31 1374 2 2
9 13 42.48 45 14.12 414 2 2
10 8 0.04 165 14.20 345 2 2

Cycle 219 GMT 14/ 3/2022 7:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 39 14.15 485 2 2
2 5 1359.92 10 11.68 2247 2 2
3 5 1370.12 10 11.74 2259 2 2
4 5 1324.04 10 11.69 2195 2 2
5 5 1412.60 10 11.31 2294 2 2
6 5 1389.20 10 11.50 2280 2 2
7 5 1391.52 10 11.53 2268 2 2
8 5 1381.68 10 11.45 2250 2 2
9 5 1372.16 10 11.37 2238 2 2
10 5 1351.68 10 11.35 2228 2 2
11 5 1337.16 10 11.50 2199 2 2
12 5 1342.36 10 11.38 2186 2 2
13 5 1325.12 10 11.42 2192 2 2
14 5 1309.48 10 11.45 2156 2 2
15 5 1333.00 10 11.39 2194 2 2
16 5 1312.08 10 11.45 2161 2 2
17 5 1331.32 10 11.34 2207 2 2
18 5 1332.76 10 11.32 2193 2 2
19 5 1314.80 10 11.31 2197 2 2
20 5 1301.84 10 11.39 2183 2 2
21 5 1428.20 10 11.09 2307 2 2
22 5 1336.44 10 11.57 2200 2 2
23 5 1354.52 10 11.28 2213 2 2
24 5 1341.56 10 11.33 2207 2 2
25 5 1345.44 10 11.32 2188 2 2
26 5 1364.04 10 11.31 2226 2 2
27 5 1376.52 10 11.22 2226 2 2
28 5 1378.12 10 11.22 2254 2 2
29 5 1355.72 10 11.33 2225 2 2
30 12 1376.08 104 10.71 2226 2 2
31 7 1369.68 24 11.17 2242 2 2
32 13 261.40 45 13.81 739 2 2
33 8 0.04 165 14.17 346 2 2

Cycle 218 GMT 4/ 3/2022 16:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 24 14.16 466 2 2
2 10 1056.12 7 12.93 1841 2 2
3 10 1088.56 5 13.31 1926 2 2
4 5 1387.32 10 11.68 2249 2 2
5 5 1358.20 10 11.73 2248 2 2
6 5 1316.76 10 11.70 2206 2 2
7 5 1315.92 10 11.63 2165 2 2
8 5 1365.48 10 11.45 2233 2 2
9 5 1342.20 10 11.56 2205 2 2
10 5 1315.00 10 11.53 2163 2 2
11 5 1395.48 10 11.31 2290 2 2
12 5 1419.36 10 11.24 2317 2 2
13 5 1314.60 10 11.65 2176 2 2
14 5 1390.96 10 11.27 2311 2 2
15 5 1387.96 10 11.31 2290 2 2
16 5 1419.76 10 11.27 2320 2 2
17 5 1314.16 10 11.65 2187 2 2
18 5 1366.92 10 11.16 2234 2 2
19 5 1345.60 10 11.35 2216 2 2
20 5 1338.68 10 11.31 2196 2 2
21 5 1334.68 10 11.27 2213 2 2
22 5 1315.60 10 11.33 2175 2 2
23 5 1334.52 10 11.30 2189 2 2
24 5 1328.04 10 11.33 2189 2 2
25 5 1303.68 10 11.27 2156 2 2
26 5 1366.72 10 11.18 2245 2 2
27 5 1387.24 10 11.11 2253 2 2
28 5 1386.48 10 11.20 2270 2 2
29 5 1382.32 10 11.17 2265 2 2
30 5 1385.56 10 11.09 2282 2 2
31 12 1499.60 104 10.30 2396 2 2
32 7 1493.48 24 11.06 2406 2 2
33 13 413.60 45 13.62 969 2 2
34 8 0.16 165 14.16 348 2 2

Cycle 217 GMT 23/ 2/2022 2:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 24 14.17 490 2 2
2 10 1001.96 8 13.18 1768 2 2
3 10 1032.48 4 13.45 1814 2 2
4 5 1368.72 10 11.91 2240 2 2
5 5 1334.52 10 11.96 2208 2 2
6 5 1301.72 10 11.77 2167 2 2
7 5 1371.88 10 11.64 2214 2 2
8 5 1375.28 10 11.72 2222 2 2
9 5 1365.64 10 11.67 2232 2 2
10 5 1347.00 10 11.57 2232 2 2
11 5 1334.44 10 11.62 2209 2 2
12 5 1322.04 10 11.59 2190 2 2
13 5 1369.16 10 11.37 2238 2 2
14 5 1362.44 10 11.42 2240 2 2
15 5 1332.24 10 11.49 2200 2 2
16 5 1332.92 10 11.39 2191 2 2
17 5 1316.32 10 11.43 2165 2 2
18 5 1303.16 10 11.45 2140 2 2
19 5 1399.76 10 11.14 2303 2 2
20 5 1389.20 10 11.34 2285 2 2
21 5 1376.52 10 11.30 2255 2 2
22 5 1369.72 10 11.30 2234 2 2
23 5 1389.52 10 11.34 2257 2 2
24 5 1407.60 10 11.29 2266 2 2
25 5 1401.24 10 11.33 2286 2 2
26 5 1308.64 10 11.59 2165 2 2
27 5 1361.00 10 11.28 2233 2 2
28 5 1355.68 10 11.35 2223 2 2
29 5 1379.32 10 11.33 2264 2 2
30 5 1378.20 10 11.27 2240 2 2
31 12 1502.80 104 10.43 2383 2 2
32 7 1496.24 24 11.06 2407 2 2
33 13 531.32 45 13.47 1127 2 2
34 8 0.04 165 14.17 339 2 2

Cycle 216 GMT 13/ 2/2022 12: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 38 14.14 475 2 2
2 5 1377.28 10 11.43 2230 2 2
3 5 1317.00 10 11.60 2195 2 2
4 12 1343.80 5 11.45 2185 2 2
5 12 2000.12 104 9.86 3056 2 2
6 7 1993.80 24 10.76 3040 2 2
7 13 752.80 45 13.27 1419 2 2
8 13 53.68 45 14.10 434 2 2
9 8 0.08 165 14.20 346 2 2

Cycle 215 GMT 11/ 2/2022 13:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 39 14.17 482 2 2
2 5 1367.04 10 11.52 2215 2 2
3 5 1358.00 10 11.74 2245 2 2
4 5 1343.68 10 11.69 2215 2 2
5 5 1321.36 10 11.66 2184 2 2
6 5 1321.96 10 11.70 2158 2 2
7 5 1396.52 10 11.42 2243 2 2
8 5 1393.12 10 11.45 2284 2 2
9 5 1410.12 10 11.35 2303 2 2
10 5 1319.20 10 11.71 2215 2 2
11 5 1329.08 10 11.46 2161 2 2
12 5 1313.28 10 11.49 2177 2 2
13 5 1320.52 10 11.43 2193 2 2
14 5 1300.64 10 11.36 2162 2 2
15 5 1376.92 10 11.25 2210 2 2
16 5 1382.64 10 11.22 2245 2 2
17 5 1368.40 10 11.11 2247 2 2
18 5 1363.36 10 11.21 2211 2 2
19 5 1363.64 10 11.11 2226 2 2
20 5 1339.64 10 11.17 2190 2 2
21 5 1326.20 10 11.25 2184 2 2
22 5 1318.68 10 11.28 2160 2 2
23 5 1312.76 10 11.32 2150 2 2
24 5 1329.76 10 11.21 2193 2 2
25 5 1329.16 10 11.22 2163 2 2
26 5 1332.08 10 11.14 2176 2 2
27 5 1314.72 10 11.08 2171 2 2
28 5 1325.28 10 11.19 2175 2 2
29 12 1427.24 104 10.30 2306 2 2
30 7 1421.44 25 11.02 2296 2 2
31 13 476.28 45 13.52 1050 2 2
32 8 0.00 165 14.17 342 2 2

Cycle 214 GMT 1/ 2/2022 23:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 24 14.10 502 2 2
2 10 1008.68 7 13.05 1775 2 2
3 10 1036.36 4 13.44 1826 2 2
4 12 1171.80 104 10.01 1933 2 2
5 7 1166.16 24 11.39 1972 2 2
6 13 401.72 45 13.69 944 2 2
7 8 0.04 165 14.18 351 2 2

Cycle 213 GMT 23/ 1/2022 9:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 24 14.14 486 2 2
2 10 1007.52 8 13.24 1776 2 2
3 10 1043.64 5 13.44 1825 2 2
4 12 1098.84 104 12.04 1884 2 2
5 7 1090.36 24 11.80 1866 2 2
6 8 0.04 165 14.20 343 2 2

Cycle 212 GMT 22/ 1/2022 22: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 38 14.12 476 2 2
2 5 1343.64 10 11.76 2179 2 2
3 5 1300.76 10 11.92 2146 2 2
4 12 1330.52 5 11.66 2175 2 2
5 12 1994.88 104 10.37 3061 2 2
6 7 1988.00 24 10.94 3056 2 2
7 13 693.32 45 13.36 1365 2 2
8 13 30.76 45 14.12 409 2 2
9 8 -0.08 165 14.20 355 2 2

Cycle 211 GMT 21/ 1/2022 0: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 39 14.15 480 2 2
2 12 1099.36 104 11.32 1885 2 2
3 7 1090.64 24 11.60 1866 2 2
4 8 0.00 165 14.16 353 2 2

Cycle 210 GMT 20/ 1/2022 2:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 24 14.12 474 2 2
2 10 1049.16 7 12.91 1829 2 2
3 10 1082.20 5 13.30 1900 2 2
4 12 1110.72 104 12.01 1907 2 2
5 7 1102.24 24 11.75 1888 2 2
6 13 15.32 45 14.14 373 2 2
7 8 -0.12 165 14.18 348 2 2

Cycle 209 GMT 19/ 1/2022 16:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 24 14.13 490 2 2
2 10 1001.72 8 13.07 1781 2 2
3 10 1036.76 5 13.38 1834 2 2
4 12 1102.60 104 12.00 1893 2 2
5 7 1094.16 24 11.75 1879 2 2
6 8 0.08 165 14.17 351 2 2

Cycle 208 GMT 19/ 1/2022 6:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 38 14.16 483 2 2
2 5 1397.84 10 11.46 2292 2 2
3 5 1388.44 10 11.46 2265 2 2
4 5 1336.52 10 11.48 2188 2 2
5 12 1417.56 5 11.09 2278 2 2
6 12 2003.80 104 9.79 3054 2 2
7 7 1997.68 24 10.80 3066 2 2
8 13 898.60 45 13.13 1626 2 2
9 13 42.32 45 14.10 419 2 2
10 8 0.00 165 14.21 348 2 2

Cycle 207 GMT 17/ 1/2022 8:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 24 14.15 487 2 2
2 12 2167.72 104 5.82 2950 2 2
3 7 2167.80 24 10.31 3279 2 2
4 13 2090.68 45 11.59 3186 2 2
5 13 1670.56 45 12.29 2656 2 2
6 13 745.68 45 13.28 1425 2 2
7 13 39.88 45 14.11 415 2 2
8 8 0.00 165 14.22 353 2 2

Cycle 206 GMT 7/ 1/2022 17:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 24 14.11 498 2 2
2 5 2181.40 10 6.02 3359 2 2
3 5 2180.76 10 5.67 1933 2 2
4 12 2169.96 104 5.84 2989 2 2
5 7 2169.96 24 10.39 3274 2 2
6 13 2085.76 45 11.71 3198 2 2
7 13 1675.44 45 12.35 2667 2 2
8 13 596.88 45 13.45 1223 2 2
9 13 39.08 45 14.12 411 2 2
10 8 -0.04 165 14.22 351 2 2

Cycle 205 GMT 29/12/2021 2:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 24 14.12 492 2 2
2 12 2168.08 104 5.81 2934 2 2
3 7 2168.00 24 10.27 3293 2 2
4 13 2083.36 45 11.65 3158 2 2
5 13 1675.92 45 12.29 2659 2 2
6 13 591.92 45 13.43 1215 2 2
7 8 0.12 165 14.19 356 2 2

Cycle 204 GMT 19/12/2021 11: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 24 14.15 481 2 2
2 5 2175.16 10 6.86 3295 2 2
3 12 2171.24 104 5.79 2825 2 2
4 7 2171.36 24 10.36 3314 2 2
5 13 2094.96 45 11.70 3196 2 2
6 13 1550.44 45 12.44 2521 2 2
7 13 514.76 45 13.51 1125 2 2
8 8 0.00 165 14.19 357 2 2

Cycle 203 GMT 9/12/2021 19:30:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 24 14.12 485 2 2
2 5 2175.20 10 5.98 3564 2 2
3 5 2175.00 10 5.78 2285 2 2
4 12 2163.24 104 5.81 2906 2 2
5 7 2162.72 24 10.43 3275 2 2
6 13 2068.76 45 11.76 3165 2 2
7 13 1797.68 45 12.22 2829 2 2
8 13 697.20 45 13.32 1371 2 2
9 13 70.92 45 14.07 458 2 2
10 8 -0.08 165 14.23 351 2 2

Cycle 202 GMT 30/11/2021 4:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 24 14.09 483 2 2
2 5 2175.28 10 5.87 2665 2 2
3 12 2160.44 104 5.85 3072 2 2
4 7 2160.56 24 10.45 3270 2 2
5 13 2078.92 45 11.78 3151 2 2
6 13 1673.92 45 12.33 2657 2 2
7 13 710.32 45 13.31 1380 2 2
8 8 0.12 165 14.22 353 2 2

Cycle 201 GMT 20/11/2021 13:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 24 14.14 497 2 2
2 12 2163.00 100 5.82 2980 2 2
3 7 2162.88 24 10.43 3287 2 2
4 13 2071.60 42 11.76 3161 2 2
5 13 1941.20 42 12.01 3022 2 2
6 13 845.84 42 13.18 1555 2 2
7 13 68.40 42 14.05 472 2 2
8 8 -0.04 165 14.21 355 2 2

Cycle 200 GMT 10/11/2021 21:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 24 14.11 483 2 2
2 12 2167.80 100 5.83 2982 2 2
3 7 2167.68 24 10.38 3286 2 2
4 13 2090.08 42 11.76 3169 2 2
5 13 1695.52 42 12.33 2685 2 2
6 13 777.92 42 13.24 1466 2 2
7 13 53.56 42 14.09 430 2 2
8 8 0.12 165 14.21 353 2 2

Cycle 199 GMT 1/11/2021 6:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 24 14.13 485 2 2
2 12 2168.00 100 5.84 2960 2 2
3 7 2168.04 24 10.44 3262 2 2
4 13 2090.16 42 11.73 3219 2 2
5 13 1558.72 42 12.43 2527 2 2
6 13 785.96 42 13.23 1487 2 2
7 13 47.80 42 14.10 428 2 2
8 8 0.00 165 14.20 356 2 2

Cycle 198 GMT 22/10/2021 15: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 24 14.09 478 2 2
2 12 2169.44 80 5.79 2811 2 2
3 7 2169.72 24 10.29 3272 2 2
4 13 2101.28 37 11.74 3229 2 2
5 13 1709.40 37 12.37 2712 2 2
6 13 970.32 37 13.10 1728 2 2
7 13 89.56 37 14.00 494 2 2
8 8 0.08 165 14.21 344 2 2

Cycle 197 GMT 12/10/2021 23:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 24 14.09 482 2 2
2 12 2168.52 80 5.78 2781 2 2
3 7 2168.60 24 10.31 3275 2 2
4 13 2091.84 37 11.77 3180 2 2
5 13 1688.92 37 12.38 2691 2 2
6 13 967.68 37 13.11 1722 2 2
7 13 81.56 37 14.02 488 2 2
8 8 0.12 165 14.20 353 2 2

Cycle 196 GMT 3/10/2021 7:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 24 14.14 474 2 2
2 12 2164.24 80 5.81 2802 2 2
3 7 2164.28 25 10.26 3277 2 2
4 13 2082.84 37 11.80 3171 2 2
5 13 1697.84 37 12.39 2696 2 2
6 13 827.68 37 13.22 1543 2 2
7 13 59.32 37 14.09 441 2 2
8 8 -0.04 165 14.22 354 2 2

Cycle 195 GMT 23/ 9/2021 16:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 24 14.12 485 2 2
2 5 2177.24 10 8.89 3228 2 2
3 12 2160.84 80 5.78 2630 2 2
4 7 2160.76 24 10.34 3270 2 2
5 13 2071.64 37 11.86 3180 2 2
6 13 1800.56 37 12.33 2817 2 2
7 13 898.12 37 13.17 1642 2 2
8 13 81.80 37 14.07 476 2 2
9 13 15.88 37 14.21 375 2 2
10 8 -0.08 165 14.25 347 2 2

Cycle 194 GMT 14/ 9/2021 0:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 24 14.11 486 2 2
2 12 2167.28 80 5.77 2689 2 2
3 7 2167.52 24 10.19 3280 2 2
4 13 2093.48 37 11.68 3190 2 2
5 13 1819.80 37 12.19 2874 2 2
6 13 1097.92 37 12.97 1917 2 2
7 13 99.52 37 14.01 514 2 2
8 8 0.24 165 14.23 351 2 2

Cycle 193 GMT 4/ 9/2021 9: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 24 14.16 480 2 2
2 12 2164.04 80 5.76 2665 2 2
3 7 2163.72 24 10.10 3275 2 2
4 13 2073.44 37 11.71 3153 2 2
5 13 1805.96 37 12.24 2848 2 2
6 13 802.32 37 13.24 1511 2 2
7 13 100.64 37 14.00 522 2 2
8 8 0.04 165 14.21 356 2 2

Cycle 192 GMT 25/ 8/2021 17:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 24 14.19 473 2 2
2 5 2171.72 10 5.89 2918 2 2
3 12 2161.56 80 5.76 2626 2 2
4 7 2161.44 24 10.10 3250 2 2
5 13 2076.80 37 11.69 3158 2 2
6 13 1816.20 37 12.26 2851 2 2
7 13 1071.24 37 13.02 1863 2 2
8 13 81.76 37 14.05 477 2 2
9 8 0.12 165 14.23 354 2 2

Cycle 191 GMT 16/ 8/2021 1:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 24 14.16 475 2 2
2 5 2178.20 10 6.08 3581 2 2
3 5 2177.68 10 6.68 3314 2 2
4 5 2171.44 10 7.19 3256 2 2
5 5 2173.64 10 5.67 1833 2 2
6 5 2170.12 10 5.90 2100 2 2
7 5 2170.72 10 5.82 2555 2 2
8 12 2157.96 80 5.80 2844 2 2
9 7 2158.28 25 10.39 3252 2 2
10 13 2079.24 37 11.85 3171 2 2
11 13 1676.64 37 12.49 2641 2 2
12 13 808.28 37 13.27 1511 2 2
13 13 90.80 37 14.03 491 2 2
14 8 0.08 165 14.24 344 2 2

Cycle 190 GMT 6/ 8/2021 10:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 24 14.13 491 2 2
2 5 2170.00 10 9.57 3243 2 2
3 5 2170.68 10 7.23 3152 2 2
4 5 2169.28 10 5.65 1710 2 2
5 12 2167.48 80 5.79 2772 2 2
6 7 2167.40 24 10.43 3274 2 2
7 13 2075.88 37 12.01 3152 2 2
8 13 1657.76 37 12.53 2646 2 2
9 13 922.52 37 13.19 1667 2 2
10 13 69.04 37 14.08 467 2 2
11 8 0.12 165 14.24 353 2 2

Cycle 189 GMT 27/ 7/2021 18:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 24 14.13 479 2 2
2 5 2170.80 10 5.91 2825 2 2
3 5 2169.72 10 5.89 2708 2 2
4 12 2169.16 80 5.80 2857 2 2
5 7 2169.08 24 10.37 3281 2 2
6 13 2083.44 37 11.87 3158 2 2
7 13 1686.64 37 12.45 2694 2 2
8 13 952.44 37 13.15 1705 2 2
9 13 86.88 37 14.05 492 2 2
10 8 0.08 165 14.24 352 2 2

Cycle 188 GMT 18/ 7/2021 3:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 24 14.17 475 2 2
2 5 2173.96 10 7.73 3284 2 2
3 5 2170.08 10 5.78 2458 2 2
4 5 2169.24 10 5.69 1900 2 2
5 12 2157.60 80 5.86 2934 2 2
6 7 2157.80 24 10.47 3264 2 2
7 13 2080.20 37 12.01 3161 2 2
8 13 1948.96 37 12.22 3026 2 2
9 13 1007.08 37 13.11 1778 2 2
10 13 108.44 37 14.01 530 2 2
11 8 0.08 165 14.23 355 2 2

Cycle 187 GMT 8/ 7/2021 11:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 24 14.17 476 2 2
2 5 2171.84 10 9.23 3227 2 2
3 5 2169.32 10 5.84 2401 2 2
4 12 2164.12 80 5.78 2616 2 2
5 7 2164.00 24 10.49 3261 2 2
6 13 2081.96 37 11.94 3180 2 2
7 13 1811.28 37 12.35 2854 2 2
8 13 930.52 37 13.16 1668 2 2
9 13 70.52 37 14.08 474 2 2
10 8 0.08 165 14.25 346 2 2

Cycle 186 GMT 28/ 6/2021 20:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 24 14.16 492 2 2
2 12 2170.32 80 8.06 3187 2 2
3 7 2165.24 24 10.64 3283 2 2
4 13 1719.72 37 12.35 2719 2 2
5 13 821.52 37 13.21 1529 2 2
6 13 82.96 37 14.04 479 2 2
7 8 -0.04 165 14.22 344 2 2

Cycle 185 GMT 24/ 6/2021 7:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 24 14.17 477 2 2
2 5 2168.96 10 5.90 2782 2 2
3 12 2158.68 80 6.62 3133 2 2
4 7 2155.36 24 10.59 3285 2 2
5 13 2035.36 37 12.02 3129 2 2
6 13 1302.00 37 12.79 2192 2 2
7 13 404.84 37 13.63 956 2 2
8 8 0.12 165 14.22 353 2 2

Cycle 184 GMT 14/ 6/2021 16:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 24 14.18 465 2 2
2 12 2170.40 80 9.42 3275 2 2
3 7 2165.16 24 10.79 3295 2 2
4 13 1300.80 37 12.76 2175 2 2
5 13 397.32 37 13.63 932 2 2
6 13 43.48 37 14.10 421 2 2
7 8 -0.04 165 14.20 349 2 2

Cycle 183 GMT 12/ 6/2021 15:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 24 14.17 482 2 2
2 12 2173.44 80 7.60 3162 2 2
3 7 2169.52 24 10.61 3309 2 2
4 13 2034.52 37 11.94 3123 2 2
5 13 916.28 37 13.13 1640 2 2
6 13 139.40 37 13.94 568 2 2
7 8 -0.04 165 14.22 339 2 2

Cycle 182 GMT 7/ 6/2021 3:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 24 14.18 481 2 2
2 12 2176.00 80 6.96 3144 2 2
3 7 2172.40 24 10.54 3321 2 2
4 13 2040.08 37 11.93 3126 2 2
5 13 1153.40 37 12.90 1976 2 2
6 13 109.36 37 13.98 520 2 2
7 13 28.00 37 14.16 384 2 2
8 8 -0.08 165 14.22 342 2 2

Cycle 181 GMT 31/ 5/2021 23:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 24 14.17 472 2 2
2 12 2171.28 80 7.40 3197 2 2
3 7 2167.04 24 10.67 3298 2 2
4 13 1898.76 37 12.11 2965 2 2
5 13 982.08 37 13.05 1753 2 2
6 13 110.56 37 13.99 522 2 2
7 8 0.08 165 14.23 338 2 2

Cycle 180 GMT 26/ 5/2021 13:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 24 14.20 470 2 2
2 12 2173.00 80 7.21 3154 2 2
3 7 2169.28 24 10.67 3272 2 2
4 13 1778.08 37 12.25 2821 2 2
5 13 1065.04 37 12.99 1861 2 2
6 13 125.12 37 13.94 557 2 2
7 8 0.12 165 14.22 346 2 2

Cycle 179 GMT 20/ 5/2021 9:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 24 14.18 475 2 2
2 5 2169.48 10 9.45 3237 2 2
3 12 2175.16 80 5.84 2935 2 2
4 7 2175.04 24 10.58 3287 2 2
5 13 2096.72 37 11.97 3191 2 2
6 13 1677.28 37 12.49 2660 2 2
7 13 705.96 37 13.34 1377 2 2
8 13 103.68 37 14.02 512 2 2
9 13 22.04 37 14.20 379 2 2
10 8 -0.08 165 14.25 344 2 2

Cycle 178 GMT 11/ 5/2021 17: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 24 14.20 477 2 2
2 12 2158.72 80 5.79 2661 2 2
3 7 2158.60 24 10.37 3257 2 2
4 13 2069.36 37 11.78 3129 2 2
5 13 1791.48 37 12.29 2799 2 2
6 13 918.32 37 13.14 1647 2 2
7 13 77.84 37 14.07 463 2 2
8 8 0.24 165 14.26 334 2 2

Cycle 177 GMT 2/ 5/2021 1:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 24 14.22 467 2 2
2 12 2159.68 80 5.74 2554 2 2
3 7 2159.68 24 10.30 3248 2 2
4 13 2079.00 37 11.72 3158 2 2
5 13 1693.24 37 12.39 2684 2 2
6 13 933.64 37 13.12 1676 2 2
7 13 76.52 37 14.06 469 2 2
8 8 0.08 165 14.23 348 2 2

Cycle 176 GMT 22/ 4/2021 10: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 24 14.22 466 2 2
2 12 2155.88 80 5.71 2489 2 2
3 7 2155.88 24 10.24 3256 2 2
4 13 2072.32 37 11.67 3162 2 2
5 13 1944.24 37 12.02 3015 2 2
6 13 1055.72 37 13.03 1828 2 2
7 13 133.56 37 13.95 559 2 2
8 8 0.04 165 14.24 333 2 2

Cycle 175 GMT 12/ 4/2021 18:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 24 14.18 476 2 2
2 12 2163.04 80 5.73 2499 2 2
3 7 2162.68 24 10.20 3275 2 2
4 13 2078.52 37 11.62 3182 2 2
5 13 1818.64 37 12.24 2864 2 2
6 13 1077.92 37 13.02 1866 2 2
7 13 127.48 37 13.97 536 2 2
8 8 0.08 165 14.24 341 2 2

Cycle 174 GMT 3/ 4/2021 3: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 24 14.22 473 2 2
2 12 2173.72 80 6.72 3149 2 2
3 7 2170.80 24 10.75 3307 2 2
4 13 2049.12 37 12.10 3148 2 2
5 13 1159.20 37 12.98 1985 2 2
6 13 378.20 37 13.67 917 2 2
7 13 37.44 37 14.15 410 2 2
8 8 -0.04 165 14.23 350 2 2

Cycle 173 GMT 28/ 3/2021 9:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 24 14.23 474 2 2
2 5 2174.04 10 9.25 3237 2 2
3 5 2164.48 10 8.38 3292 2 2
4 5 2164.12 10 5.79 2443 2 2
5 5 2166.12 10 5.74 2154 2 2
6 5 2166.00 10 5.64 1853 2 2
7 12 2159.40 80 5.73 2402 2 2
8 7 2159.44 24 10.44 3260 2 2
9 13 2088.28 37 11.95 3193 2 2
10 13 1963.48 37 12.26 3043 2 2
11 13 883.36 37 13.23 1614 2 2
12 13 77.16 37 14.09 472 2 2
13 8 0.00 165 14.26 342 2 2

Cycle 172 GMT 18/ 3/2021 17:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 24 14.22 483 2 2
2 5 2164.84 10 8.74 3221 2 2
3 5 2164.80 10 7.70 3210 2 2
4 5 2164.68 10 8.57 3177 2 2
5 12 2155.04 80 5.66 2218 2 2
6 7 2154.84 24 10.28 3264 2 2
7 13 2066.00 37 11.87 3147 2 2
8 13 1806.04 37 12.38 2839 2 2
9 13 1060.44 37 13.05 1859 2 2
10 13 71.16 37 14.08 460 2 2
11 8 0.00 165 14.24 344 2 2

Cycle 171 GMT 9/ 3/2021 2:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 24 14.24 466 2 2
2 5 2165.84 10 6.10 3704 2 2
3 5 2163.96 10 5.94 2929 2 2
4 5 2164.24 10 7.04 3211 2 2
5 12 2157.84 50 5.76 2541 2 2
6 7 2157.80 24 10.58 3278 2 2
7 13 2075.88 37 11.79 3141 2 2
8 13 1680.64 37 12.44 2686 2 2
9 13 945.00 37 13.14 1694 2 2
10 13 72.04 37 14.06 469 2 2
11 8 0.08 165 14.22 343 2 2

Cycle 170 GMT 27/ 2/2021 10:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 24 14.20 487 2 2
2 12 2158.56 50 5.81 2585 2 2
3 7 2158.64 24 10.60 3257 2 2
4 13 2080.56 37 11.80 3153 2 2
5 13 1678.68 37 12.44 2675 2 2
6 13 821.48 37 13.23 1531 2 2
7 13 89.20 37 14.05 492 2 2
8 8 -0.08 165 14.21 348 2 2

Cycle 169 GMT 17/ 2/2021 19: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 24 14.22 464 2 2
2 5 2164.52 10 8.66 3247 2 2
3 12 2171.88 50 7.03 3157 2 2
4 7 2169.72 24 10.79 3310 2 2
5 13 2059.76 37 11.98 3167 2 2
6 13 1331.08 37 12.80 2202 2 2
7 13 421.20 37 13.62 977 2 2
8 13 46.72 37 14.12 426 2 2
9 8 0.00 165 14.20 349 2 2

Cycle 168 GMT 11/ 2/2021 3:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 24 14.17 482 2 2
2 12 2158.40 50 5.81 2531 2 2
3 7 2158.24 24 10.51 3264 2 2
4 13 2072.60 37 11.79 3149 2 2
5 13 1788.64 37 12.33 2823 2 2
6 13 1034.56 37 13.06 1822 2 2
7 13 65.00 37 14.10 443 2 2
8 8 0.00 165 14.23 343 2 2

Cycle 167 GMT 1/ 2/2021 11:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 24 14.22 488 2 2
2 12 2157.16 50 5.76 2542 2 2
3 7 2157.00 24 10.52 3252 2 2
4 13 2068.40 37 11.77 3178 2 2
5 13 1815.04 37 12.30 2856 2 2
6 13 935.20 37 13.14 1693 2 2
7 13 75.52 37 14.05 479 2 2
8 8 0.08 165 14.20 353 2 2

Cycle 166 GMT 22/ 1/2021 20:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 24 14.25 490 2 2
2 12 2160.20 50 5.77 2499 2 2
3 7 2160.16 25 10.54 3252 2 2
4 13 2079.28 37 11.78 3187 2 2
5 13 1672.84 37 12.47 2667 2 2
6 13 944.08 37 13.15 1698 2 2
7 13 74.00 37 14.08 464 2 2
8 8 0.12 165 14.22 344 2 2

Cycle 165 GMT 13/ 1/2021 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 24 14.27 478 2 2
2 5 2163.12 10 9.55 3208 2 2
3 12 2155.92 50 5.78 2338 2 2
4 7 2155.60 24 10.68 3252 2 2
5 13 2061.60 37 11.99 3130 2 2
6 13 1800.60 37 12.44 2832 2 2
7 13 1049.48 37 13.09 1849 2 2
8 13 72.60 37 14.11 465 2 2
9 8 0.08 165 14.25 347 2 2

Cycle 164 GMT 3/ 1/2021 13:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 24 14.26 464 2 2
2 5 2162.88 10 6.69 3268 2 2
3 5 2163.16 10 6.03 3397 2 2
4 5 2162.08 10 5.90 2726 2 2
5 5 2163.04 10 5.80 2602 2 2
6 12 2157.28 50 6.20 3050 2 2
7 7 2156.28 24 10.94 3243 2 2
8 13 2068.12 37 12.06 3170 2 2
9 13 1515.16 37 12.70 2464 2 2
10 13 903.52 37 13.23 1639 2 2
11 13 49.28 37 14.16 425 2 2
12 8 0.04 165 14.24 344 2 2

Cycle 163 GMT 24/12/2020 22:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 24 14.25 484 2 2
2 5 2163.76 10 10.47 3235 2 2
3 5 2162.64 10 6.01 3281 2 2
4 5 2163.48 10 9.06 3248 2 2
5 12 2169.92 50 6.30 2887 2 2
6 7 2168.72 24 11.06 3264 2 2
7 13 2072.08 37 12.13 3185 2 2
8 13 1670.16 37 12.61 2656 2 2
9 13 767.60 37 13.35 1455 2 2
10 13 53.40 37 14.15 433 2 2
11 8 0.08 165 14.23 346 2 2

Cycle 162 GMT 15/12/2020 17:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 24 14.30 471 2 2
2 12 2169.00 50 9.57 3214 2 2
3 7 2165.40 24 11.06 3292 2 2
4 13 1638.00 37 12.57 2615 2 2
5 13 795.48 37 13.30 1483 2 2
6 13 87.12 37 14.09 484 2 2
7 8 0.08 165 14.24 343 2 2

Cycle 161 GMT 12/12/2020 10:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 24 14.25 472 2 2
2 5 2162.80 10 10.56 3295 2 2
3 5 2167.12 10 10.32 3274 2 2
4 5 2162.80 10 8.62 3228 2 2
5 5 2163.00 10 5.70 1811 2 2
6 5 2163.60 10 5.67 1782 2 2
7 12 2157.60 50 5.82 2791 2 2
8 7 2157.56 24 11.02 3246 2 2
9 13 2068.32 37 12.22 3174 2 2
10 13 1658.36 37 12.65 2629 2 2
11 13 758.56 37 13.36 1437 2 2
12 13 65.60 37 14.13 450 2 2
13 8 0.00 165 14.26 344 2 2

Cycle 160 GMT 2/12/2020 18:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 24 14.22 489 2 2
2 5 2162.00 10 5.38 3476 2 2
3 5 2162.44 10 8.53 3197 2 2
4 5 2163.44 10 6.14 3053 2 2
5 12 2148.96 50 5.91 2721 2 2
6 7 2148.04 24 11.03 3251 2 2
7 13 2041.72 37 12.04 3130 2 2
8 13 1768.20 37 12.46 2793 2 2
9 13 974.44 37 13.16 1726 2 2
10 13 77.72 37 14.11 474 2 2
11 8 0.00 165 14.24 350 2 2

Cycle 159 GMT 23/11/2020 3:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 24 14.22 484 2 2
2 5 2162.16 10 9.86 3221 2 2
3 5 2161.96 10 5.75 2084 2 2
4 5 2163.28 10 5.92 2920 2 2
5 5 2162.52 10 9.50 3242 2 2
6 12 2128.68 50 9.60 3208 2 2
7 7 2124.24 24 11.11 3232 2 2
8 13 1723.20 37 12.44 2735 2 2
9 13 817.40 37 13.26 1508 2 2
10 13 81.28 37 14.07 487 2 2
11 8 0.04 165 14.20 352 2 2

Cycle 158 GMT 13/11/2020 12:30:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 24 14.24 488 2 2
2 12 2154.28 50 6.35 2988 2 2
3 7 2153.12 24 11.10 3254 2 2
4 13 2055.76 37 12.13 3147 2 2
5 13 1503.84 37 12.70 2422 2 2
6 13 734.12 37 13.34 1420 2 2
7 13 47.60 37 14.15 428 2 2
8 8 0.00 165 14.20 352 2 2

Cycle 157 GMT 3/11/2020 21:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 24 14.25 494 2 2
2 12 2152.92 50 7.03 2933 2 2
3 7 2150.44 24 11.05 3238 2 2
4 13 2031.96 37 12.11 3131 2 2
5 13 1452.88 37 12.72 2382 2 2
6 13 546.68 37 13.52 1159 2 2
7 13 36.60 37 14.19 406 2 2
8 8 -0.08 165 14.21 348 2 2

Cycle 156 GMT 25/10/2020 5:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 24 14.27 496 2 2
2 12 2159.80 30 6.12 2656 2 2
3 7 2159.32 24 11.35 3282 2 2
4 13 2075.24 37 12.02 3174 2 2
5 13 1538.00 37 12.65 2481 2 2
6 13 681.36 37 13.38 1341 2 2
7 13 49.76 37 14.15 432 2 2
8 8 0.08 165 14.20 354 2 2

Cycle 155 GMT 15/10/2020 14:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 24 14.27 494 2 2
2 12 2152.04 30 5.88 2549 2 2
3 7 2152.08 24 11.40 3279 2 2
4 13 2063.08 37 12.06 3167 2 2
5 13 1522.28 37 12.67 2487 2 2
6 13 925.56 37 13.19 1662 2 2
7 13 65.16 37 14.13 459 2 2
8 8 -0.04 165 14.21 355 2 2

Cycle 154 GMT 5/10/2020 22:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 24 14.28 480 2 2
2 5 2158.36 10 10.73 3236 2 2
3 5 2158.44 10 5.79 2270 2 2
4 12 2153.56 30 6.50 2971 2 2
5 7 2152.72 25 11.51 3253 2 2
6 13 2047.24 37 12.18 3151 2 2
7 13 1620.84 37 12.62 2584 2 2
8 13 708.20 37 13.39 1378 2 2
9 13 52.04 37 14.16 434 2 2
10 8 0.12 165 14.21 350 2 2

Cycle 153 GMT 26/ 9/2020 7:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 24 14.30 474 2 2
2 5 2159.24 10 10.72 3280 2 2
3 5 2159.40 10 10.68 3245 2 2
4 5 2158.76 10 10.61 3237 2 2
5 5 2158.12 10 5.91 2846 2 2
6 5 2158.28 10 8.40 3283 2 2
7 12 2150.00 30 6.21 2499 2 2
8 7 2149.56 25 11.55 3258 2 2
9 13 2055.20 37 12.17 3164 2 2
10 13 1633.64 37 12.62 2620 2 2
11 13 718.84 37 13.38 1396 2 2
12 13 97.84 37 14.09 506 2 2
13 8 0.04 165 14.23 349 2 2

Cycle 152 GMT 16/ 9/2020 16:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 24 14.29 494 2 2
2 12 2164.92 30 7.67 2992 2 2
3 7 2163.32 24 11.38 3322 2 2
4 13 2060.24 37 12.11 3174 2 2
5 13 1643.64 37 12.57 2637 2 2
6 13 698.32 37 13.39 1359 2 2
7 13 38.64 37 14.20 411 2 2
8 8 0.12 165 14.21 351 2 2

Cycle 151 GMT 8/ 9/2020 14:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 24 14.29 483 2 2
2 12 2151.68 30 6.82 2713 2 2
3 7 2150.12 24 11.44 3241 2 2
4 13 2043.04 37 12.09 3150 2 2
5 13 1763.68 37 12.46 2795 2 2
6 13 678.08 37 13.40 1332 2 2
7 13 37.56 37 14.19 414 2 2
8 8 0.00 165 14.20 350 2 2

Cycle 150 GMT 29/ 8/2020 23:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 24 14.30 480 2 2
2 12 2150.56 30 6.88 2727 2 2
3 7 2149.40 24 11.48 3257 2 2
4 13 2054.60 37 12.10 3151 2 2
5 13 1507.24 37 12.68 2454 2 2
6 13 749.76 37 13.33 1444 2 2
7 13 55.08 37 14.16 440 2 2
8 8 -0.08 165 14.22 348 2 2

Cycle 149 GMT 20/ 8/2020 8:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 24 14.28 495 2 2
2 5 2162.04 10 10.18 3229 2 2
3 12 2150.16 30 7.13 2604 2 2
4 7 2148.76 24 11.61 3243 2 2
5 13 2054.28 37 12.15 3156 2 2
6 13 1501.48 37 12.72 2427 2 2
7 13 609.72 37 13.48 1243 2 2
8 13 53.96 37 14.18 429 2 2
9 8 0.00 165 14.22 350 2 2

Cycle 148 GMT 10/ 8/2020 16:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 24 14.33 473 2 2
2 12 2146.92 30 7.15 2750 2 2
3 7 2145.40 25 11.45 3235 2 2
4 13 2048.20 37 12.11 3162 2 2
5 13 1490.88 37 12.71 2432 2 2
6 13 709.92 37 13.38 1386 2 2
7 13 47.04 37 14.20 423 2 2
8 8 0.08 165 14.23 350 2 2

Cycle 147 GMT 1/ 8/2020 1:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 24 14.30 490 2 2
2 5 2156.88 10 10.97 3240 2 2
3 12 2155.64 30 7.07 2615 2 2
4 7 2154.08 24 11.59 3247 2 2
5 13 2046.96 37 12.19 3148 2 2
6 13 1496.44 37 12.73 2448 2 2
7 13 716.16 37 13.40 1382 2 2
8 13 48.96 37 14.21 416 2 2
9 8 0.00 165 14.24 346 2 2

Cycle 146 GMT 22/ 7/2020 10:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 24 14.31 470 2 2
2 5 2155.12 10 10.40 3269 2 2
3 5 2156.76 10 5.79 2293 2 2
4 12 2146.04 30 8.07 2948 2 2
5 7 2143.32 24 11.50 3241 2 2
6 13 2021.80 37 12.20 3135 2 2
7 13 1471.32 37 12.75 2420 2 2
8 13 556.44 37 13.55 1169 2 2
9 13 21.28 37 14.27 381 2 2
10 8 0.00 165 14.25 345 2 2

Cycle 145 GMT 12/ 7/2020 18:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 24 14.34 468 2 2
2 5 2150.20 10 10.36 3240 2 2
3 5 2158.88 10 11.26 3256 2 2
4 5 2150.48 10 11.29 3303 2 2
5 5 2151.24 10 5.96 2789 2 2
6 5 2151.56 10 10.05 3245 2 2
7 5 2152.24 10 10.84 3229 2 2
8 5 2151.16 10 11.16 3242 2 2
9 12 2166.80 30 7.99 3007 2 2
10 7 2165.16 24 11.53 3324 2 2
11 13 2058.68 37 12.18 3177 2 2
12 13 1479.56 37 12.74 2417 2 2
13 13 454.16 37 13.65 1034 2 2
14 13 62.68 37 14.18 447 2 2
15 8 0.08 165 14.24 346 2 2

Cycle 144 GMT 3/ 7/2020 6: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 24 14.33 480 2 2
2 5 2150.12 10 10.94 3253 2 2
3 5 2151.00 10 8.72 3200 2 2
4 5 2151.80 10 9.87 3192 2 2
5 5 2152.88 10 8.90 3249 2 2
6 12 2144.40 30 10.57 3230 2 2
7 7 2140.40 24 11.55 3280 2 2
8 13 1872.00 37 12.40 2941 2 2
9 13 1002.40 37 13.13 1781 2 2
10 13 123.12 37 14.05 547 2 2
11 8 0.04 165 14.23 346 2 2

Cycle 143 GMT 23/ 6/2020 14:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 24 14.32 484 2 2
2 12 2161.56 30 9.14 3023 2 2
3 7 2158.52 24 11.53 3307 2 2
4 13 1901.28 37 12.36 2965 2 2
5 13 1183.68 37 12.97 2017 2 2
6 13 279.40 37 13.83 784 2 2
7 8 0.08 165 14.24 347 2 2

Cycle 142 GMT 16/ 6/2020 12:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 24 14.35 467 2 2
2 5 2152.84 8 11.45 3290 2 2
3 5 2150.92 8 11.14 3229 2 2
4 5 2150.44 8 6.19 3885 2 2
5 5 2151.40 8 6.06 3132 2 2
6 5 2152.00 8 11.53 3243 2 2
7 5 2150.32 8 8.55 3311 2 2
8 12 2146.48 30 10.62 3241 2 2
9 7 2143.44 24 11.57 3280 2 2
10 13 2024.76 37 12.24 3123 2 2
11 13 1118.28 37 13.05 1935 2 2
12 13 192.04 37 13.95 650 2 2
13 13 12.64 37 14.28 369 2 2
14 8 0.00 165 14.22 348 2 2

Cycle 141 GMT 6/ 6/2020 21:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 24 14.33 479 2 2
2 5 2156.44 8 10.14 3212 2 2
3 5 2156.20 8 8.36 3279 2 2
4 5 2152.24 8 5.94 2810 2 2
5 12 2145.48 30 9.31 3017 2 2
6 7 2142.56 24 11.59 3246 2 2
7 13 2020.80 37 12.25 3132 2 2
8 13 1155.04 37 13.02 1967 2 2
9 13 268.68 37 13.87 760 2 2
10 13 21.00 37 14.27 381 2 2
11 8 0.04 165 14.25 343 2 2

Cycle 140 GMT 28/ 5/2020 5:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 24 14.36 468 2 2
2 5 2150.48 8 10.33 3250 2 2
3 5 2150.84 8 6.07 3340 2 2
4 5 2149.84 8 10.89 3253 2 2
5 5 2159.20 8 10.80 3254 2 2
6 5 2150.12 8 9.04 3184 2 2
7 5 2157.48 8 9.20 3217 2 2
8 12 2145.76 30 9.63 3252 2 2
9 7 2142.72 24 11.47 3287 2 2
10 13 2021.32 37 12.22 3109 2 2
11 13 1414.96 37 12.80 2336 2 2
12 13 331.52 37 13.79 856 2 2
13 13 40.56 37 14.24 407 2 2
14 8 0.08 165 14.26 341 2 2

Cycle 139 GMT 18/ 5/2020 14:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 24 14.35 484 2 2
2 5 2153.56 8 11.32 3239 2 2
3 5 2145.24 8 11.48 3228 2 2
4 5 2146.16 8 11.26 3236 2 2
5 5 2146.56 8 11.43 3257 2 2
6 5 2145.64 8 11.62 3286 2 2
7 5 2145.72 8 11.46 3230 2 2
8 5 2145.68 8 11.40 3294 2 2
9 5 2147.40 8 11.15 3288 2 2
10 5 2144.92 8 10.61 3245 2 2
11 5 2148.44 8 11.39 3315 2 2
12 5 2145.16 8 10.48 3253 2 2
13 5 2152.96 8 10.18 3208 2 2
14 5 2146.44 8 9.73 3251 2 2
15 5 2145.00 8 9.61 3277 2 2
16 5 2145.80 8 10.37 3280 2 2
17 5 2148.48 8 9.05 3236 2 2
18 5 2154.16 8 9.98 3276 2 2
19 5 2145.48 8 9.16 3222 2 2
20 12 2153.72 30 9.49 3259 2 2
21 7 2150.44 24 11.53 3295 2 2
22 13 1881.28 37 12.34 2950 2 2
23 13 1289.96 37 12.88 2163 2 2
24 13 232.80 37 13.91 713 2 2
25 8 0.16 165 14.26 344 2 2

Cycle 138 GMT 9/ 5/2020 10:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 24 14.39 466 2 2
2 5 2145.96 8 11.69 3268 2 2
3 5 2148.20 8 11.15 3261 2 2
4 12 2155.56 30 10.17 3244 2 2
5 7 2152.44 24 11.62 3302 2 2
6 13 2020.96 37 12.26 3125 2 2
7 13 1255.96 37 12.92 2122 2 2
8 13 311.12 37 13.80 829 2 2
9 8 -0.04 165 14.25 342 2 2

Cycle 137 GMT 2/ 5/2020 15:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 24 14.33 485 2 2
2 5 2147.12 8 11.53 3269 2 2
3 5 2145.36 8 11.47 3231 2 2
4 5 2151.44 8 11.44 3274 2 2
5 5 2148.36 8 11.48 3257 2 2
6 5 2147.72 8 11.56 3238 2 2
7 5 2146.92 8 11.37 3225 2 2
8 5 2153.80 8 11.05 3251 2 2
9 5 2145.00 8 11.52 3252 2 2
10 5 2149.68 8 10.88 3253 2 2
11 5 2150.64 8 10.43 3241 2 2
12 12 2138.16 30 10.24 3253 2 2
13 7 2134.88 24 11.59 3265 2 2
14 13 2007.80 37 12.22 3097 2 2
15 13 1267.04 37 12.93 2112 2 2
16 13 187.92 37 13.96 645 2 2
17 13 37.20 37 14.24 408 2 2
18 8 0.12 165 14.24 344 2 2

Cycle 136 GMT 23/ 4/2020 0:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 24 14.36 463 2 2
2 5 2147.76 8 11.35 3247 2 2
3 5 2146.44 8 11.46 3310 2 2
4 12 2154.80 30 10.56 3190 2 2
5 7 2151.84 24 11.67 3294 2 2
6 13 2023.88 37 12.26 3135 2 2
7 13 1119.32 37 13.05 1913 2 2
8 13 204.32 37 13.94 662 2 2
9 13 17.48 37 14.28 371 2 2
10 8 -0.08 165 14.21 345 2 2

Cycle 135 GMT 18/ 4/2020 11:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 24 14.36 471 2 2
2 5 2146.00 8 11.20 3288 2 2
3 5 2148.08 8 11.27 3283 2 2
4 5 2147.64 8 11.85 3302 2 2
5 5 2148.68 8 11.50 3294 2 2
6 5 2145.24 8 11.40 3257 2 2
7 5 2147.84 8 11.33 3261 2 2
8 5 2148.68 8 11.29 3234 2 2
9 5 2145.28 8 11.07 3227 2 2
10 5 2148.52 8 10.99 3268 2 2
11 5 2152.72 8 10.75 3229 2 2
12 5 2145.92 8 11.31 3303 2 2
13 12 2140.36 30 10.27 3263 2 2
14 7 2136.72 24 11.64 3296 2 2
15 13 1882.52 37 12.36 2928 2 2
16 13 1157.48 37 13.00 1994 2 2
17 13 132.20 37 14.05 557 2 2
18 8 0.04 165 14.25 348 2 2

Cycle 134 GMT 8/ 4/2020 20:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 24 14.36 473 2 2
2 5 2146.68 8 11.53 3269 2 2
3 5 2145.92 8 11.27 3274 2 2
4 5 2144.92 8 11.37 3245 2 2
5 5 2147.64 8 11.36 3252 2 2
6 12 2154.32 30 10.45 3234 2 2
7 7 2151.08 24 11.71 3290 2 2
8 13 2018.76 37 12.23 3111 2 2
9 13 1135.20 37 13.02 1948 2 2
10 13 133.16 37 14.06 553 2 2
11 8 0.12 165 14.26 337 2 2

Cycle 133 GMT 31/ 3/2020 21:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 24 14.36 460 2 2
2 5 2148.92 8 11.67 3267 2 2
3 5 2148.80 8 11.45 3241 2 2
4 5 2147.36 8 11.10 3254 2 2
5 5 2149.28 8 11.33 3231 2 2
6 5 2148.00 8 11.63 3254 2 2
7 5 2148.08 8 11.34 3260 2 2
8 12 2141.04 30 10.08 3154 2 2
9 7 2137.60 24 11.69 3293 2 2
10 13 2008.88 37 12.26 3118 2 2
11 13 1125.44 37 13.03 1939 2 2
12 13 215.08 37 13.93 689 2 2
13 8 0.08 165 14.25 341 2 2

Cycle 132 GMT 22/ 3/2020 6:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 24 14.35 475 2 2
2 5 2146.24 8 11.25 3245 2 2
3 12 2154.76 30 10.92 3223 2 2
4 7 2151.72 24 11.65 3287 2 2
5 13 2024.40 37 12.25 3126 2 2
6 13 989.08 37 13.14 1754 2 2
7 13 125.92 37 14.06 544 2 2
8 8 0.12 165 14.25 335 2 2

Cycle 131 GMT 18/ 3/2020 4:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 24 14.35 467 2 2
2 5 2145.36 8 11.41 3286 2 2
3 5 2145.16 8 11.12 3241 2 2
4 5 2153.00 8 11.55 3241 2 2
5 5 2148.72 8 11.57 3233 2 2
6 5 2145.32 8 11.56 3267 2 2
7 12 2137.96 30 10.18 3186 2 2
8 7 2134.28 24 11.63 3293 2 2
9 13 1877.64 37 12.36 2947 2 2
10 13 1039.60 37 13.08 1835 2 2
11 13 139.00 37 14.04 555 2 2
12 8 0.12 165 14.25 336 2 2

Cycle 130 GMT 8/ 3/2020 12:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 24 14.36 461 2 2
2 5 2145.92 8 11.52 3257 2 2
3 5 2145.24 8 11.54 3252 2 2
4 5 2151.16 8 11.46 3273 2 2
5 5 2150.52 8 11.55 3290 2 2
6 5 2149.88 8 11.43 3311 2 2
7 5 2145.60 8 11.35 3246 2 2
8 5 2151.56 8 11.37 3260 2 2
9 12 2135.84 30 11.09 3276 2 2
10 7 2131.68 24 11.69 3264 2 2
11 13 1740.64 37 12.44 2749 2 2
12 13 1168.72 37 12.96 1988 2 2
13 13 120.16 37 14.05 534 2 2
14 8 0.12 165 14.22 346 2 2

Cycle 129 GMT 27/ 2/2020 21:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 24 14.33 485 2 2
2 5 2145.12 8 11.55 3297 2 2
3 5 2147.52 8 11.23 3249 2 2
4 5 2146.84 8 11.48 3245 2 2
5 5 2154.04 8 11.55 3266 2 2
6 5 2146.36 8 11.63 3264 2 2
7 12 2128.48 30 11.52 3244 2 2
8 7 2124.16 24 11.70 3261 2 2
9 13 1853.76 37 12.36 2910 2 2
10 13 1235.80 37 12.91 2085 2 2
11 13 145.04 37 14.01 573 2 2
12 8 0.16 165 14.23 337 2 2

Cycle 128 GMT 18/ 2/2020 6:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 24 14.33 476 2 2
2 5 2145.48 8 11.66 3245 2 2
3 12 2147.96 30 10.74 3145 2 2
4 7 2144.88 24 11.62 3281 2 2
5 13 2013.76 37 12.21 3124 2 2
6 13 1124.52 37 12.99 1949 2 2
7 13 218.84 37 13.90 695 2 2
8 8 -0.16 165 14.19 352 2 2

Cycle 127 GMT 8/ 2/2020 15: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 24 14.32 490 2 2
2 5 2145.76 8 11.38 3235 2 2
3 5 2149.76 8 11.39 3240 2 2
4 12 2130.48 30 10.40 3121 2 2
5 7 2126.88 24 11.66 3261 2 2
6 13 1871.52 37 12.37 2940 2 2
7 13 1132.16 37 13.01 1943 2 2
8 13 128.52 37 14.05 549 2 2
9 8 0.16 165 14.21 352 2 2

Cycle 126 GMT 29/ 1/2020 23:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 24 14.33 492 2 2
2 5 2146.72 8 11.63 3224 2 2
3 5 2148.68 8 11.67 3266 2 2
4 12 2139.84 30 10.68 3138 2 2
5 7 2136.32 24 11.68 3299 2 2
6 13 2005.24 37 12.24 3126 2 2
7 13 1095.84 37 13.04 1891 2 2
8 13 186.36 37 13.95 652 2 2
9 8 0.08 165 14.21 351 2 2

Cycle 125 GMT 20/ 1/2020 8:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 24 14.35 490 2 2
2 5 2147.04 8 11.60 3231 2 2
3 12 2137.56 30 10.58 3107 2 2
4 7 2134.00 24 11.64 3299 2 2
5 13 2000.24 37 12.24 3106 2 2
6 13 1128.80 37 13.00 1952 2 2
7 13 206.76 37 13.92 681 2 2
8 8 -0.08 165 14.20 352 2 2

Cycle 124 GMT 10/ 1/2020 17:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 24 14.36 483 2 2
2 12 2133.44 30 10.66 3107 2 2
3 7 2129.36 24 11.62 3234 2 2
4 13 1866.88 37 12.37 2929 2 2
5 13 1132.72 37 13.00 1948 2 2
6 13 212.88 37 13.92 679 2 2
7 8 0.00 165 14.19 350 2 2

Cycle 123 GMT 1/ 1/2020 1:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 24 14.34 472 2 2
2 5 2148.92 8 11.56 3260 2 2
3 12 2155.48 30 10.88 3183 2 2
4 7 2152.20 24 11.59 3294 2 2
5 13 1779.16 37 12.44 2824 2 2
6 13 1066.12 37 13.06 1843 2 2
7 13 157.68 37 14.00 600 2 2
8 8 0.12 165 14.21 348 2 2

Cycle 122 GMT 23/12/2019 2: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 24 14.34 493 2 2
2 5 2150.40 8 11.76 3246 2 2
3 5 2146.80 8 11.75 3260 2 2
4 12 2126.76 30 11.83 3232 2 2
5 7 2122.60 24 11.74 3252 2 2
6 13 1864.08 37 12.36 2918 2 2
7 13 982.40 37 13.13 1742 2 2
8 13 106.80 37 14.08 521 2 2
9 8 0.16 165 14.20 349 2 2

Cycle 121 GMT 13/12/2019 10:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 24 14.35 475 2 2
2 12 2138.92 30 10.73 3131 2 2
3 7 2135.32 24 11.63 3269 2 2
4 13 2001.28 37 12.26 3112 2 2
5 13 1239.36 37 12.93 2097 2 2
6 13 171.60 37 14.00 609 2 2
7 8 0.00 165 14.22 340 2 2

Cycle 120 GMT 3/12/2019 19:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 24 14.37 493 2 2
2 12 2128.60 30 10.72 3113 2 2
3 7 2124.64 24 11.69 3207 2 2
4 13 1851.32 37 12.41 2899 2 2
5 13 998.80 37 13.14 1763 2 2
6 13 124.36 37 14.06 548 2 2
7 8 0.12 165 14.22 347 2 2

Cycle 119 GMT 24/11/2019 4:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 24 14.33 477 2 2
2 5 2145.68 8 11.61 3256 2 2
3 12 2137.32 30 10.71 3120 2 2
4 7 2133.84 24 11.70 3264 2 2
5 13 2006.36 37 12.29 3112 2 2
6 13 1148.20 37 13.02 1967 2 2
7 13 237.72 37 13.90 720 2 2
8 8 0.12 165 14.21 350 2 2

Cycle 118 GMT 14/11/2019 12:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 24 14.36 472 2 2
2 5 2145.36 8 11.88 3297 2 2
3 5 2145.96 8 11.68 3226 2 2
4 12 2139.32 30 10.85 3154 2 2
5 7 2135.80 24 11.68 3288 2 2
6 13 1751.36 37 12.50 2780 2 2
7 13 1017.80 37 13.14 1788 2 2
8 13 230.64 37 13.91 702 2 2
9 8 0.20 165 14.19 350 2 2

Cycle 117 GMT 4/11/2019 21:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 24 14.34 470 2 2
2 12 2133.04 30 10.78 3145 2 2
3 7 2129.08 24 11.69 3279 2 2
4 13 1858.00 37 12.42 2906 2 2
5 13 1139.76 37 13.03 1944 2 2
6 13 127.28 37 14.06 554 2 2
7 8 0.00 165 14.21 350 2 2

Cycle 116 GMT 26/10/2019 6:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 24 14.36 487 2 2
2 12 2132.88 30 10.80 3108 2 2
3 7 2129.20 24 11.70 3265 2 2
4 13 2000.16 37 12.29 3100 2 2
5 13 1134.48 37 13.03 1936 2 2
6 13 196.76 37 13.96 657 2 2
7 8 0.04 165 14.20 341 2 2

Cycle 115 GMT 16/10/2019 14:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 20 14.33 495 2 2
2 12 2134.08 24 10.74 3098 2 2
3 7 2131.24 24 11.86 3275 2 2
4 13 2015.36 37 12.28 3134 2 2
5 13 1393.36 37 12.82 2307 2 2
6 13 307.76 37 13.83 814 2 2
7 8 0.16 165 14.20 350 2 2

Cycle 114 GMT 6/10/2019 23:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 20 14.32 497 2 2
2 5 2147.68 8 11.73 3235 2 2
3 12 2135.60 24 10.67 3061 2 2
4 7 2132.80 24 11.90 3229 2 2
5 13 2011.36 37 12.30 3108 2 2
6 13 1143.52 37 13.03 1962 2 2
7 13 369.32 37 13.75 919 2 2
8 8 0.08 165 14.19 348 2 2

Cycle 113 GMT 27/ 9/2019 8:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 20 14.38 476 2 2
2 12 2133.68 24 10.72 3066 2 2
3 7 2130.52 24 11.85 3235 2 2
4 13 1997.52 37 12.29 3094 2 2
5 13 1136.56 37 13.04 1942 2 2
6 13 220.80 37 13.93 694 2 2
7 8 0.08 165 14.21 344 2 2

Cycle 112 GMT 17/ 9/2019 17:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 20 14.37 469 2 2
2 12 2137.24 24 10.76 3077 2 2
3 7 2134.68 24 11.85 3244 2 2
4 13 2017.88 37 12.27 3131 2 2
5 13 1137.72 37 13.04 1947 2 2
6 13 255.52 37 13.89 739 2 2
7 8 0.00 165 14.19 349 2 2

Cycle 111 GMT 8/ 9/2019 2: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 20 14.39 477 2 2
2 12 2137.68 24 10.76 3070 2 2
3 7 2134.64 24 11.84 3250 2 2
4 13 2005.60 37 12.28 3102 2 2
5 13 1241.60 37 12.96 2093 2 2
6 13 289.80 37 13.85 802 2 2
7 8 0.04 165 14.21 345 2 2

Cycle 110 GMT 29/ 8/2019 10:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 20 14.38 475 2 2
2 12 2144.96 24 10.78 3102 2 2
3 7 2142.36 24 11.82 3290 2 2
4 13 2014.68 37 12.27 3126 2 2
5 13 1273.36 37 12.93 2150 2 2
6 13 329.40 37 13.79 855 2 2
7 8 0.00 165 14.19 349 2 2

Cycle 109 GMT 19/ 8/2019 19:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 20 14.39 496 2 2
2 12 2130.12 24 10.68 3106 2 2
3 7 2127.08 24 11.83 3269 2 2
4 13 2001.52 37 12.27 3116 2 2
5 13 1147.36 37 13.03 1964 2 2
6 13 382.60 37 13.74 938 2 2
7 8 -0.04 165 14.18 352 2 2

Cycle 108 GMT 10/ 8/2019 4:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 20 14.42 471 2 2
2 12 2130.52 24 10.75 3070 2 2
3 7 2127.92 24 11.83 3238 2 2
4 13 2011.36 37 12.25 3122 2 2
5 13 1275.64 37 12.91 2149 2 2
6 13 346.16 37 13.77 893 2 2
7 8 0.12 165 14.20 354 2 2

Cycle 107 GMT 31/ 7/2019 13:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 20 14.41 471 2 2
2 12 2119.36 24 10.76 3064 2 2
3 7 2116.16 24 11.87 3233 2 2
4 13 1986.44 37 12.26 3091 2 2
5 13 1251.56 37 12.93 2121 2 2
6 13 335.40 37 13.81 858 2 2
7 13 42.36 37 14.25 410 2 2
8 8 -0.04 165 14.19 345 2 2

Cycle 106 GMT 21/ 7/2019 22: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 20 14.40 484 2 2
2 12 2139.16 24 10.68 3084 2 2
3 7 2136.44 24 11.82 3268 2 2
4 13 2011.84 37 12.23 3131 2 2
5 13 1249.96 37 12.94 2103 2 2
6 13 312.76 37 13.83 828 2 2
7 8 0.20 165 14.21 345 2 2

Cycle 105 GMT 12/ 7/2019 6:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 20 14.40 475 2 2
2 12 2126.28 24 10.68 3067 2 2
3 7 2122.96 24 11.82 3265 2 2
4 13 1990.52 37 12.26 3090 2 2
5 13 1237.72 37 12.94 2094 2 2
6 13 321.48 37 13.82 841 2 2
7 13 13.64 37 14.30 364 2 2
8 8 -0.08 165 14.17 344 2 2

Cycle 104 GMT 2/ 7/2019 15:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 20 14.38 473 2 2
2 5 2141.52 8 12.03 3277 2 2
3 5 2144.04 8 11.77 3256 2 2
4 12 2117.08 24 10.38 3146 2 2
5 7 2113.32 24 11.84 3280 2 2
6 13 1870.52 37 12.38 2929 2 2
7 13 1173.32 37 13.00 2015 2 2
8 13 143.20 37 14.05 584 2 2
9 13 16.04 37 14.29 378 2 2
10 8 0.00 165 14.16 350 2 2

Cycle 103 GMT 23/ 6/2019 0:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 20 14.40 477 2 2
2 5 2144.36 8 11.58 3252 2 2
3 12 2126.72 24 10.77 3078 2 2
4 7 2123.44 24 11.78 3236 2 2
5 13 1991.00 37 12.20 3089 2 2
6 13 1251.84 37 12.90 2102 2 2
7 13 344.36 37 13.78 879 2 2
8 8 0.08 165 14.18 351 2 2

Cycle 102 GMT 13/ 6/2019 9: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 20 14.38 470 2 2
2 5 2142.52 8 11.70 3247 2 2
3 7 2123.76 50 10.80 3248 2 2
4 13 1869.24 37 12.28 2940 2 2
5 13 1160.44 37 12.94 2002 2 2
6 13 243.88 37 13.90 736 2 2
7 13 22.08 37 14.26 385 2 2
8 8 0.00 165 14.18 346 2 2

Cycle 101 GMT 3/ 6/2019 17:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 20 14.39 492 2 2
2 7 2135.16 51 10.77 3260 2 2
3 13 2002.88 37 12.14 3111 2 2
4 13 1107.88 37 12.99 1922 2 2
5 13 206.84 37 13.95 680 2 2
6 13 16.88 37 14.27 377 2 2
7 8 0.00 165 14.15 349 2 2

Cycle 100 GMT 25/ 5/2019 2:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 20 14.41 467 2 2
2 7 2123.88 50 10.92 3232 2 2
3 13 1991.60 37 12.14 3074 2 2
4 13 1254.28 37 12.85 2119 2 2
5 13 332.08 37 13.79 851 2 2
6 13 27.80 37 14.25 392 2 2
7 8 0.00 165 14.17 346 2 2

Cycle 99 GMT 15/ 5/2019 11:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 20 14.38 483 2 2
2 5 2133.12 8 11.86 3213 2 2
3 5 2130.72 8 11.89 3209 2 2
4 5 2130.76 8 11.90 3220 2 2
5 5 2130.44 8 11.82 3253 2 2
6 5 2131.40 8 11.77 3215 2 2
7 7 2128.36 51 10.89 3242 2 2
8 13 1996.04 37 12.07 3099 2 2
9 13 1109.84 37 12.97 1920 2 2
10 13 225.12 37 13.92 696 2 2
11 8 0.08 165 14.17 347 2 2

Cycle 98 GMT 5/ 5/2019 20:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 20 14.40 475 2 2
2 5 2132.76 8 11.66 3226 2 2
3 5 2131.92 8 11.73 3220 2 2
4 5 2131.00 8 11.92 3231 2 2
5 7 2125.96 51 10.99 3240 2 2
6 13 1995.76 37 12.10 3099 2 2
7 13 1234.12 37 12.86 2082 2 2
8 13 308.20 37 13.81 825 2 2
9 13 27.84 37 14.25 397 2 2
10 8 -0.08 165 14.16 347 2 2

Cycle 97 GMT 26/ 4/2019 5: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 20 14.39 489 2 2
2 5 2134.40 8 11.84 3226 2 2
3 5 2137.40 8 12.10 3285 2 2
4 7 2125.76 50 11.05 3252 2 2
5 13 1990.32 37 12.18 3086 2 2
6 13 1112.92 37 13.00 1923 2 2
7 13 213.36 37 13.94 692 2 2
8 8 0.04 165 14.20 346 2 2

Cycle 96 GMT 16/ 4/2019 13:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 20 14.43 472 2 2
2 5 2130.24 8 11.85 3253 2 2
3 5 2131.24 8 12.28 3259 2 2
4 5 2130.32 8 12.20 3243 2 2
5 7 2121.48 50 11.34 3236 2 2
6 13 1990.20 37 12.15 3093 2 2
7 13 1117.48 37 12.98 1948 2 2
8 13 125.96 37 14.08 555 2 2
9 8 0.12 165 14.20 348 2 2

Cycle 95 GMT 6/ 4/2019 22:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 20 14.43 475 2 2
2 5 2132.72 8 11.69 3240 2 2
3 7 2124.44 50 11.47 3247 2 2
4 13 1854.52 37 12.33 2914 2 2
5 13 986.28 37 13.09 1758 2 2
6 13 123.24 37 14.08 557 2 2
7 8 0.12 165 14.20 351 2 2

Cycle 94 GMT 28/ 3/2019 6:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 20 14.42 472 2 2
2 5 2132.32 8 12.07 3263 2 2
3 5 2131.92 8 11.72 3210 2 2
4 5 2132.88 8 11.81 3216 2 2
5 5 2130.00 8 11.99 3226 2 2
6 7 2124.60 50 11.12 3240 2 2
7 13 1861.80 37 12.26 2927 2 2
8 13 1132.68 37 12.95 1959 2 2
9 13 122.36 37 14.09 552 2 2
10 13 26.52 37 14.25 396 2 2
11 8 -0.08 165 14.17 347 2 2

Cycle 93 GMT 18/ 3/2019 15:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 20 14.41 484 2 2
2 5 2130.36 8 11.82 3233 2 2
3 5 2135.20 8 11.89 3244 2 2
4 7 2127.72 51 11.07 3242 2 2
5 13 1996.52 37 12.12 3089 2 2
6 13 1240.16 37 12.86 2099 2 2
7 13 183.92 37 14.00 641 2 2
8 8 0.08 165 14.21 341 2 2

Cycle 92 GMT 9/ 3/2019 0:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 20 14.41 486 2 2
2 5 2130.04 8 11.95 3247 2 2
3 5 2132.52 8 12.12 3238 2 2
4 5 2130.00 8 11.87 3234 2 2
5 7 2126.08 50 11.08 3253 2 2
6 13 2011.56 37 12.17 3115 2 2
7 13 1138.20 37 12.98 1972 2 2
8 13 369.56 37 13.77 909 2 2
9 8 -0.04 165 14.18 345 2 2

Cycle 91 GMT 27/ 2/2019 9: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 20 14.45 470 2 2
2 5 2130.04 8 11.99 3225 2 2
3 5 2129.92 8 11.95 3215 2 2
4 7 2125.52 50 11.35 3246 2 2
5 13 1991.76 37 12.22 3090 2 2
6 13 1251.60 37 12.90 2124 2 2
7 13 178.88 37 14.02 635 2 2
8 8 0.04 165 14.19 342 2 2

Cycle 90 GMT 17/ 2/2019 17:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 20 14.42 483 2 2
2 5 2133.92 8 11.98 3236 2 2
3 5 2130.20 8 11.92 3234 2 2
4 5 2133.04 8 12.00 3239 2 2
5 7 2124.60 51 11.32 3249 2 2
6 13 1992.32 37 12.23 3089 2 2
7 13 1088.56 37 13.06 1897 2 2
8 13 156.04 37 14.05 602 2 2
9 8 0.20 165 14.19 348 2 2

Cycle 89 GMT 8/ 2/2019 2:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 20 14.43 465 2 2
2 7 2118.20 50 11.17 3218 2 2
3 13 1861.48 37 12.39 2921 2 2
4 13 1123.40 37 13.06 1919 2 2
5 13 201.96 37 14.00 669 2 2
6 8 0.00 165 14.19 345 2 2

Cycle 88 GMT 29/ 1/2019 11:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 20 14.45 472 2 2
2 5 2129.88 8 11.91 3227 2 2
3 7 2117.80 50 11.46 3233 2 2
4 13 1840.56 37 12.39 2882 2 2
5 13 1135.68 37 13.03 1951 2 2
6 13 202.60 37 14.01 659 2 2
7 13 15.68 37 14.31 362 2 2
8 8 0.08 165 14.15 341 2 2

Cycle 87 GMT 19/ 1/2019 20:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 20 14.41 479 2 2
2 5 2130.72 8 12.01 3242 2 2
3 7 2122.64 50 11.29 3244 2 2
4 13 1863.68 37 12.37 2924 2 2
5 13 1128.28 37 13.05 1918 2 2
6 13 345.20 37 13.83 870 2 2
7 8 0.08 165 14.18 348 2 2

Cycle 86 GMT 10/ 1/2019 5:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 20 14.47 484 2 2
2 7 2123.00 50 11.28 3242 2 2
3 13 1992.00 37 12.29 3081 2 2
4 13 1222.60 37 12.99 2062 2 2
5 13 281.96 37 13.91 789 2 2
6 8 0.04 165 14.20 343 2 2

Cycle 85 GMT 31/12/2018 14:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 20 14.47 479 2 2
2 5 2132.88 8 11.94 3255 2 2
3 5 2129.96 8 12.47 3258 2 2
4 7 2130.60 50 11.45 3251 2 2
5 13 1735.72 37 12.51 2757 2 2
6 13 1152.36 37 13.04 1980 2 2
7 13 114.12 37 14.15 530 2 2
8 8 -0.04 165 14.20 341 2 2

Cycle 84 GMT 21/12/2018 22:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 20 14.44 487 2 2
2 7 2115.68 50 11.25 3227 2 2
3 13 1982.60 37 12.32 3070 2 2
4 13 1071.16 37 13.14 1846 2 2
5 13 153.00 37 14.09 585 2 2
6 8 0.04 165 14.21 340 2 2

Cycle 83 GMT 12/12/2018 7:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 20 14.46 496 2 2
2 5 2132.60 8 11.94 3237 2 2
3 7 2113.40 50 11.47 3227 2 2
4 13 1844.12 37 12.44 2899 2 2
5 13 1119.92 37 13.08 1928 2 2
6 13 168.16 37 14.06 615 2 2
7 8 0.16 165 14.18 346 2 2

Cycle 82 GMT 2/12/2018 16:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 20 14.47 478 2 2
2 7 2124.44 51 11.34 3256 2 2
3 13 1859.96 37 12.48 2914 2 2
4 13 1124.44 37 13.12 1953 2 2
5 13 190.88 37 14.03 669 2 2
6 8 0.20 165 14.20 350 2 2

Cycle 81 GMT 23/11/2018 1:26:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 20 14.46 485 2 2
2 7 2115.28 50 11.27 3253 2 2
3 13 1982.52 37 12.35 3096 2 2
4 13 994.20 37 13.23 1752 2 2
5 13 136.60 37 14.13 562 2 2
6 8 0.08 165 14.23 342 2 2

Cycle 80 GMT 13/11/2018 10: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 20 14.48 480 2 2
2 7 2110.56 50 11.27 3240 2 2
3 13 1854.52 37 12.51 2915 2 2
4 13 1246.24 37 13.05 2097 2 2
5 13 156.40 37 14.11 596 2 2
6 8 0.04 165 14.22 341 2 2

Cycle 79 GMT 3/11/2018 18:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 20 14.48 481 2 2
2 5 2133.44 8 12.07 3266 2 2
3 7 2108.76 51 11.30 3215 2 2
4 13 1851.60 37 12.52 2903 2 2
5 13 1119.48 37 13.15 1922 2 2
6 13 176.88 37 14.07 636 2 2
7 8 0.04 165 14.19 346 2 2

Cycle 78 GMT 25/10/2018 3:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 20 14.52 481 2 2
2 5 2129.92 8 12.13 3224 2 2
3 5 2130.16 8 12.22 3227 2 2
4 7 2111.52 50 11.45 3233 2 2
5 13 1843.72 37 12.49 2911 2 2
6 13 1086.44 37 13.17 1879 2 2
7 13 175.24 37 14.09 623 2 2
8 8 0.08 165 14.23 344 2 2

Cycle 77 GMT 15/10/2018 12:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 20 14.51 476 2 2
2 7 2113.04 50 11.35 3225 2 2
3 13 1854.08 37 12.57 2901 2 2
4 13 1260.64 37 13.10 2090 2 2
5 13 154.88 37 14.13 593 2 2
6 8 0.08 165 14.24 339 2 2

Cycle 76 GMT 5/10/2018 21:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 20 14.52 486 2 2
2 7 2113.92 50 11.35 3229 2 2
3 13 1848.68 37 12.58 2889 2 2
4 13 1088.20 37 13.24 1881 2 2
5 13 173.00 37 14.12 619 2 2
6 8 0.08 165 14.25 339 2 2

Cycle 75 GMT 26/ 9/2018 6:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 20 14.53 487 2 2
2 7 2109.16 51 11.38 3223 2 2
3 13 1974.20 37 12.46 3053 2 2
4 13 1192.04 37 13.16 2013 2 2
5 13 226.72 37 14.06 706 2 2
6 8 0.08 165 14.24 340 2 2

Cycle 74 GMT 16/ 9/2018 15:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 20 14.52 479 2 2
2 7 2110.80 50 11.39 3231 2 2
3 13 1977.00 37 12.48 3068 2 2
4 13 1107.88 37 13.24 1908 2 2
5 13 178.04 37 14.12 635 2 2
6 8 0.12 165 14.24 345 2 2

Cycle 73 GMT 7/ 9/2018 0: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 20 14.52 495 2 2
2 7 2114.04 50 11.39 3238 2 2
3 13 1847.72 37 12.62 2910 2 2
4 13 968.24 37 13.36 1743 2 2
5 13 207.28 37 14.10 672 2 2
6 8 0.00 165 14.25 344 2 2

Cycle 72 GMT 28/ 8/2018 8:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 20 14.55 496 2 2
2 7 2109.32 51 11.45 3230 2 2
3 13 1836.88 37 12.64 2896 2 2
4 13 955.12 37 13.39 1706 2 2
5 13 188.00 37 14.13 649 2 2
6 8 0.00 165 14.26 348 2 2

Cycle 71 GMT 18/ 8/2018 17:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 20 14.56 473 2 2
2 7 2110.52 51 11.44 3229 2 2
3 13 1699.92 37 12.77 2726 2 2
4 13 979.76 37 13.40 1741 2 2
5 13 111.76 37 14.25 529 2 2
6 8 0.16 165 14.27 343 2 2

Cycle 70 GMT 9/ 8/2018 2:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 20 14.56 477 2 2
2 7 2110.92 50 11.53 3240 2 2
3 13 1980.44 37 12.54 3076 2 2
4 13 974.68 37 13.40 1725 2 2
5 13 110.80 37 14.25 521 2 2
6 8 0.08 165 14.27 342 2 2

Cycle 69 GMT 30/ 7/2018 10:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 20 14.56 467 2 2
2 7 2101.68 50 11.56 3220 2 2
3 13 1711.84 37 12.81 2730 2 2
4 13 1006.84 37 13.39 1790 2 2
5 13 115.52 37 14.25 531 2 2
6 8 0.08 165 14.28 340 2 2

Cycle 68 GMT 20/ 7/2018 19:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 20 14.59 479 2 2
2 7 2094.40 50 11.65 3227 2 2
3 13 1961.72 37 12.59 3072 2 2
4 13 1054.88 37 13.36 1852 2 2
5 13 132.00 37 14.23 559 2 2
6 8 -0.04 165 14.26 344 2 2
7 14 -0.04 35 14.30 344 2 2

Cycle 67 GMT 11/ 7/2018 4:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 20 14.58 474 2 2
2 7 2106.96 50 11.67 3231 2 2
3 13 1847.32 37 12.74 2904 2 2
4 13 1082.20 37 13.38 1850 2 2
5 13 91.12 37 14.30 490 2 2
6 8 0.12 165 14.27 342 2 2

Cycle 66 GMT 1/ 7/2018 13:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 20 14.60 475 2 2
2 7 1829.56 50 11.99 2872 2 2
3 13 1555.72 37 12.98 2516 2 2
4 13 661.12 37 13.70 1326 2 2
5 13 69.80 37 14.32 463 2 2
6 8 0.00 165 14.25 346 2 2

Cycle 65 GMT 21/ 6/2018 22:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 20 14.60 469 2 2
2 7 2106.64 50 11.81 3225 2 2
3 13 1834.16 37 12.82 2884 2 2
4 13 1094.92 37 13.40 1879 2 2
5 13 138.84 37 14.23 569 2 2
6 8 0.12 165 14.27 341 2 2

Cycle 64 GMT 12/ 6/2018 7:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 20 14.59 463 2 2
2 7 2104.84 51 11.85 3230 2 2
3 13 1979.56 37 12.69 3076 2 2
4 13 1045.24 37 13.44 1812 2 2
5 13 77.28 37 14.34 466 2 2
6 8 0.00 165 14.31 338 2 2

Cycle 63 GMT 2/ 6/2018 16:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 20 14.61 462 2 2
2 7 2103.04 50 11.98 3227 2 2
3 13 1968.28 31 12.85 3072 2 2
4 13 1095.20 31 13.49 1878 2 2
5 13 490.36 31 13.92 1086 2 2
6 13 64.80 31 14.35 455 2 2
7 8 0.04 165 14.29 341 2 2

Cycle 62 GMT 24/ 5/2018 1:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 20 14.61 464 2 2
2 7 2105.48 50 12.02 3219 2 2
3 13 1708.80 31 13.09 2710 2 2
4 13 1142.48 31 13.48 1957 2 2
5 13 511.96 31 13.91 1113 2 2
6 13 34.36 31 14.39 403 2 2
7 8 0.00 165 14.27 341 2 2

Cycle 61 GMT 14/ 5/2018 10:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 20 14.62 484 2 2
2 7 2101.84 50 12.11 3221 2 2
3 13 1967.60 31 12.91 3060 2 2
4 13 1088.96 31 13.51 1878 2 2
5 13 217.16 31 14.20 690 2 2
6 13 45.68 31 14.39 423 2 2
7 8 0.00 165 14.29 339 2 2

Cycle 60 GMT 4/ 5/2018 18:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 20 14.61 467 2 2
2 7 2103.88 51 12.16 3223 2 2
3 13 1835.80 31 13.06 2891 2 2
4 13 1080.80 31 13.54 1863 2 2
5 13 196.80 31 14.22 650 2 2
6 13 42.96 31 14.41 417 2 2
7 8 0.08 165 14.29 342 2 2

Cycle 59 GMT 25/ 4/2018 3:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 20 14.63 479 2 2
2 7 2102.96 51 12.24 3224 2 2
3 13 1829.36 31 13.09 2886 2 2
4 13 949.96 31 13.63 1695 2 2
5 13 203.00 31 14.22 669 2 2
6 13 39.56 31 14.41 412 2 2
7 8 -0.04 165 14.28 341 2 2

Cycle 58 GMT 15/ 4/2018 12:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 20 14.63 460 2 2
2 7 2099.24 50 12.33 3211 2 2
3 13 1823.76 31 13.10 2880 2 2
4 13 945.08 31 13.64 1691 2 2
5 13 207.28 31 14.22 678 2 2
6 13 37.52 31 14.42 411 2 2
7 8 0.04 165 14.29 341 2 2

Cycle 57 GMT 5/ 4/2018 21:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 20 14.61 463 2 2
2 5 2103.80 8 13.20 3201 2 2
3 5 2100.68 8 12.92 3274 2 2
4 5 2100.20 8 12.93 3259 2 2
5 5 2100.12 8 13.01 3261 2 2
6 5 2102.40 8 12.86 3256 2 2
7 7 2099.60 51 12.17 3220 2 2
8 13 1967.92 31 12.93 3057 2 2
9 13 1075.44 31 13.54 1871 2 2
10 13 311.92 31 14.12 828 2 2
11 13 31.00 31 14.43 395 2 2
12 8 -0.04 165 14.29 337 2 2

Cycle 56 GMT 27/ 3/2018 6: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 20 14.65 466 2 2
2 5 2101.00 8 13.46 3224 2 2
3 5 2106.00 8 13.15 3256 2 2
4 5 2110.76 8 13.02 3212 2 2
5 5 2106.96 8 12.84 3212 2 2
6 7 2093.52 50 12.29 3210 2 2
7 13 1817.44 31 13.08 2860 2 2
8 13 950.40 31 13.63 1681 2 2
9 13 209.20 31 14.22 675 2 2
10 13 39.56 31 14.42 408 2 2
11 8 -0.08 165 14.30 333 2 2

Cycle 55 GMT 17/ 3/2018 14:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 20 14.66 480 2 2
2 5 2100.60 8 13.24 3210 2 2
3 5 2101.40 8 13.12 3248 2 2
4 5 2104.44 8 13.25 3295 2 2
5 5 2099.92 8 13.37 3299 2 2
6 7 2094.04 50 12.39 3211 2 2
7 13 1815.88 31 13.11 2869 2 2
8 13 1073.00 31 13.57 1858 2 2
9 13 177.20 31 14.26 642 2 2
10 8 0.12 165 14.35 339 2 2

Cycle 54 GMT 7/ 3/2018 23:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 20 14.66 482 2 2
2 5 2100.48 8 13.41 3258 2 2
3 5 2101.16 8 13.29 3211 2 2
4 5 2103.32 8 13.17 3238 2 2
5 5 2099.92 8 13.19 3254 2 2
6 5 2101.32 8 13.08 3276 2 2
7 7 2097.92 51 12.40 3221 2 2
8 13 1822.76 31 13.12 2866 2 2
9 13 1069.76 31 13.58 1840 2 2
10 13 171.16 31 14.29 620 2 2
11 13 36.56 31 14.45 406 2 2
12 8 -0.08 165 14.31 345 2 2

Cycle 53 GMT 26/ 2/2018 8:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 20 14.66 495 2 2
2 5 2101.12 8 13.38 3275 2 2
3 5 2101.28 8 13.12 3199 2 2
4 7 2089.16 51 12.63 3213 2 2
5 13 1809.96 31 13.16 2852 2 2
6 13 1206.64 31 13.52 2045 2 2
7 13 139.44 31 14.32 578 2 2
8 13 14.88 31 14.49 371 2 2
9 8 0.00 165 14.31 338 2 2

Cycle 52 GMT 16/ 2/2018 17:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 20 14.67 464 2 2
2 5 2106.64 8 13.48 3204 2 2
3 5 2101.28 8 13.27 3208 2 2
4 7 2094.64 50 12.57 3212 2 2
5 13 1816.48 31 13.16 2861 2 2
6 13 923.32 31 13.69 1668 2 2
7 13 184.28 31 14.27 651 2 2
8 8 0.08 165 14.34 346 2 2

Cycle 51 GMT 7/ 2/2018 2: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 20 14.69 468 2 2
2 5 2100.00 8 13.48 3224 2 2
3 5 2102.36 8 13.49 3241 2 2
4 7 2085.24 50 12.62 3212 2 2
5 13 1676.16 31 13.25 2684 2 2
6 13 1096.28 31 13.60 1884 2 2
7 13 186.56 31 14.29 647 2 2
8 8 0.08 165 14.37 337 2 2

Cycle 50 GMT 28/ 1/2018 10:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 20 14.71 474 2 2
2 5 2100.28 8 13.61 3212 2 2
3 5 2100.76 8 13.49 3227 2 2
4 5 2101.80 8 13.44 3263 2 2
5 7 2093.80 50 12.63 3206 2 2
6 13 1820.08 35 13.11 2860 2 2
7 13 919.12 35 13.66 1662 2 2
8 13 75.72 35 14.42 469 2 2
9 8 -0.04 165 14.36 341 2 2

Cycle 49 GMT 18/ 1/2018 19:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 20 14.71 483 2 2
2 7 2090.72 50 12.78 3205 2 2
3 13 1684.44 35 13.26 2657 2 2
4 13 801.80 35 13.77 1512 2 2
5 13 73.08 35 14.43 466 2 2
6 8 0.08 165 14.35 342 2 2

Cycle 48 GMT 9/ 1/2018 4:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 20 14.70 472 2 2
2 5 2101.76 8 13.66 3214 2 2
3 7 2099.04 51 12.69 3212 2 2
4 13 1670.36 35 13.23 2657 2 2
5 13 776.04 35 13.79 1467 2 2
6 13 72.92 35 14.44 464 2 2
7 8 0.12 165 14.37 342 2 2

Cycle 47 GMT 30/12/2017 13: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 20 14.71 477 2 2
2 5 2100.64 8 13.67 3228 2 2
3 7 2088.96 50 12.78 3197 2 2
4 13 1668.00 35 13.25 2666 2 2
5 13 925.84 35 13.71 1661 2 2
6 13 67.68 35 14.45 458 2 2
7 8 0.00 165 14.37 340 2 2

Cycle 46 GMT 20/12/2017 21:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 20 14.72 478 2 2
2 7 2093.04 50 12.85 3212 2 2
3 13 1689.64 35 13.28 2676 2 2
4 13 810.52 35 13.79 1513 2 2
5 13 80.52 35 14.45 468 2 2
6 8 0.04 165 14.37 339 2 2

Cycle 45 GMT 11/12/2017 6:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 20 14.71 488 2 2
2 7 2088.32 50 12.87 3203 2 2
3 13 1677.60 35 13.30 2670 2 2
4 13 930.72 35 13.72 1680 2 2
5 13 86.04 35 14.47 475 2 2
6 8 0.08 165 14.39 341 2 2

Cycle 44 GMT 1/12/2017 15:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 20 14.70 485 2 2
2 7 2089.68 50 12.88 3207 2 2
3 13 1826.92 35 13.23 2858 2 2
4 13 912.08 35 13.74 1641 2 2
5 13 67.84 35 14.48 461 2 2
6 8 0.12 165 14.39 339 2 2

Cycle 43 GMT 22/11/2017 0:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 20 14.71 475 2 2
2 7 2085.08 51 12.87 3204 2 2
3 13 1671.40 35 13.31 2659 2 2
4 13 774.92 35 13.83 1468 2 2
5 13 71.64 35 14.48 458 2 2
6 8 0.16 165 14.39 339 2 2

Cycle 42 GMT 12/11/2017 9:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 20 14.73 474 2 2
2 7 2092.28 50 12.89 3212 2 2
3 13 1688.48 35 13.31 2673 2 2
4 13 820.16 35 13.81 1528 2 2
5 13 87.52 35 14.47 476 2 2
6 8 0.04 165 14.39 336 2 2

Cycle 41 GMT 2/11/2017 17:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 20 14.72 486 2 2
2 7 2085.96 50 12.91 3195 2 2
3 13 1811.12 35 13.25 2844 2 2
4 13 892.64 35 13.76 1625 2 2
5 13 65.32 35 14.51 441 2 2
6 8 0.20 165 14.40 336 2 2

Cycle 40 GMT 24/10/2017 2:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 20 14.74 463 2 2
2 7 2087.96 51 12.90 3205 2 2
3 13 1547.44 35 13.39 2490 2 2
4 13 951.88 35 13.73 1705 2 2
5 13 65.64 35 14.50 453 2 2
6 8 0.04 165 14.39 340 2 2

Cycle 39 GMT 14/10/2017 11:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 20 14.70 466 2 2
2 7 2083.96 51 12.91 3199 2 2
3 13 1811.12 35 13.26 2842 2 2
4 13 874.12 35 13.78 1603 2 2
5 13 64.12 35 14.52 443 2 2
6 8 0.00 165 14.39 341 2 2

Cycle 38 GMT 4/10/2017 20:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 20 14.72 474 2 2
2 7 2083.56 50 12.95 3201 2 2
3 13 1682.28 35 13.32 2667 2 2
4 13 801.40 35 13.84 1508 2 2
5 13 74.40 35 14.51 463