SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8546 WMO= 3901270


Cycle 314 GMT 31/ 7/2024 12:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 30 10.06 734 3 3
2 3 1024.12 1 7.71 2011 3 3
3 3 1019.68 1 7.68 2009 3 3
4 12 1224.20 50 6.68 2316 3 3
5 7 1224.40 24 6.76 2330 3 3
6 13 1140.68 46 6.94 2229 3 3
7 13 1016.96 46 7.33 2056 3 3
8 13 308.84 46 9.19 1076 3 3
9 8 0.04 150 10.16 599 3 3

Cycle 313 GMT 21/ 7/2024 17:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 31 10.10 752 3 3
2 12 1196.76 50 6.95 2271 3 3
3 7 1196.56 24 6.93 2397 3 3
4 13 1117.36 46 7.13 2229 3 3
5 13 986.28 46 7.41 2087 3 3
6 13 408.36 46 8.96 1242 3 3
7 8 0.08 150 10.21 599 3 3

Cycle 312 GMT 11/ 7/2024 23:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 31 10.16 738 3 3
2 12 1205.84 50 7.02 2318 3 3
3 7 1205.20 24 7.13 2343 3 3
4 13 1123.52 46 7.25 2243 3 3
5 13 752.32 46 8.19 1708 3 3
6 13 178.24 46 9.72 878 3 3
7 8 0.08 150 10.25 595 3 3

Cycle 311 GMT 2/ 7/2024 4:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 31 10.13 739 3 3
2 12 1185.72 5 7.30 2226 3 3
3 12 1763.88 50 5.92 3053 3 3
4 7 1761.88 24 5.96 3101 3 3
5 13 1724.44 46 5.97 3100 3 3
6 13 1680.32 46 6.13 3011 3 3
7 13 1606.40 46 6.33 2900 3 3
8 13 1502.96 46 6.45 2795 3 3
9 13 1116.24 46 7.36 2277 3 3
10 13 548.68 46 8.77 1439 3 3
11 8 0.20 150 10.29 603 3 3

Cycle 310 GMT 30/ 6/2024 23:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 30 10.19 739 3 3
2 12 1212.84 50 6.84 2519 3 3
3 7 1213.20 24 7.18 2354 3 3
4 13 1135.60 46 7.25 2292 3 3
5 13 1004.52 46 7.64 2100 3 3
6 13 258.88 46 9.52 1002 3 3
7 8 0.04 150 10.28 590 3 3

Cycle 309 GMT 21/ 6/2024 5:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 31 10.24 736 3 3
2 12 1195.48 50 7.24 2311 3 3
3 7 1194.72 24 7.28 2323 3 3
4 13 1105.40 46 7.52 2201 3 3
5 13 716.68 46 8.45 1660 3 3
6 13 127.28 46 9.93 804 3 3
7 8 0.08 150 10.33 584 3 3

Cycle 308 GMT 11/ 6/2024 10:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 30 10.28 731 3 3
2 3 1020.04 1 8.18 2063 3 3
3 12 1193.24 50 7.41 2278 3 3
4 7 1191.80 24 7.56 2287 3 3
5 13 1098.64 46 7.55 2298 3 3
6 13 838.36 46 8.19 1880 3 3
7 13 116.16 46 10.00 792 3 3
8 8 -0.08 150 10.35 591 3 3

Cycle 307 GMT 1/ 6/2024 16: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 31 10.23 740 3 3
2 12 1173.72 5 7.67 2264 3 3
3 12 1753.36 50 6.36 3057 3 3
4 7 1748.04 24 6.50 3087 3 3
5 13 1636.44 46 6.62 2962 3 3
6 13 1381.64 46 7.13 2648 3 3
7 13 686.64 46 8.64 1677 3 3
8 13 113.12 46 10.04 791 3 3
9 8 0.04 150 10.37 595 3 3

Cycle 306 GMT 31/ 5/2024 12:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 30 10.27 730 3 3
2 12 1204.96 50 7.42 2289 3 3
3 7 1203.68 24 7.51 2335 3 3
4 13 1099.68 46 7.67 2246 3 3
5 13 840.60 46 8.30 1849 3 3
6 13 109.52 46 10.05 772 3 3
7 8 0.12 150 10.35 594 3 3

Cycle 305 GMT 21/ 5/2024 17:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 30 10.33 723 3 3
2 12 1188.24 50 7.59 2255 3 3
3 7 1186.56 24 7.64 2274 3 3
4 13 1090.36 46 7.84 2175 3 3
5 13 571.48 46 8.97 1467 3 3
6 13 62.84 46 10.21 699 3 3
7 8 0.04 150 10.38 588 3 3

Cycle 304 GMT 11/ 5/2024 23: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 10.34 724 3 3
2 12 1181.76 50 7.71 2262 3 3
3 7 1180.60 24 7.77 2287 3 3
4 13 1079.00 46 7.98 2160 3 3
5 13 667.08 46 8.78 1625 3 3
6 13 48.44 46 10.28 667 3 3
7 8 -0.04 150 10.41 585 3 3

Cycle 303 GMT 2/ 5/2024 4:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 31 10.31 755 3 3
2 12 1140.64 5 7.85 2216 3 3
3 12 1739.40 50 6.67 3108 3 3
4 7 1733.20 24 6.71 3130 3 3
5 13 1608.08 46 6.96 2985 3 3
6 13 1338.56 46 7.51 2598 3 3
7 13 616.76 46 9.01 1541 3 3
8 13 64.04 46 10.25 714 3 3
9 8 0.00 150 10.44 588 3 3

Cycle 302 GMT 1/ 5/2024 0:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 30 10.35 732 3 3
2 12 1199.52 50 7.67 2297 3 3
3 7 1197.08 24 7.74 2320 3 3
4 13 1091.44 46 8.01 2165 3 3
5 13 675.76 46 8.88 1592 3 3
6 13 50.72 46 10.26 689 3 3
7 8 -0.04 150 10.43 590 3 3

Cycle 301 GMT 21/ 4/2024 6:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 30 10.36 733 3 3
2 12 1203.24 50 7.69 2348 3 3
3 7 1200.84 24 7.82 2355 3 3
4 13 1098.76 46 7.89 2321 3 3
5 13 690.84 46 8.88 1642 3 3
6 13 51.52 46 10.31 675 3 3
7 8 0.04 150 10.44 594 3 3

Cycle 300 GMT 11/ 4/2024 11:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 30 10.42 724 3 3
2 12 1184.44 50 7.90 2271 3 3
3 7 1182.44 24 7.96 2298 3 3
4 13 1085.32 46 8.14 2193 3 3
5 13 663.24 46 8.99 1591 3 3
6 13 40.04 46 10.35 668 3 3
7 8 -0.04 150 10.47 589 3 3

Cycle 299 GMT 1/ 4/2024 17:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 31 10.43 712 3 3
2 3 968.24 -1 11.55 0 3 3
3 3 1026.16 1 8.54 2087 3 3
4 12 1194.08 5 8.19 2276 3 3
5 12 1738.32 50 7.00 3083 3 3
6 7 1732.60 24 7.06 3093 3 3
7 13 1610.56 46 7.30 2928 3 3
8 13 1048.60 46 8.33 2156 3 3
9 13 187.48 46 10.07 891 3 3
10 8 0.12 150 10.51 585 3 3

Cycle 298 GMT 31/ 3/2024 13:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 30 10.44 711 3 3
2 12 1189.12 50 7.97 2249 3 3
3 7 1186.16 24 8.02 2283 3 3
4 13 1078.76 46 8.23 2152 3 3
5 13 534.68 46 9.30 1394 3 3
6 13 45.32 46 10.35 672 3 3
7 8 0.04 150 10.47 589 3 3

Cycle 297 GMT 21/ 3/2024 19: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 30 10.43 736 3 3
2 12 1187.32 50 7.98 2272 3 3
3 7 1185.20 24 8.11 2286 3 3
4 13 1089.16 46 8.03 2358 3 3
5 13 533.80 46 9.33 1405 3 3
6 13 23.52 46 10.43 633 3 3
7 8 0.04 150 10.51 577 3 3

Cycle 296 GMT 12/ 3/2024 0:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 30 10.51 707 3 3
2 12 1181.84 50 8.10 2235 3 3
3 7 1179.40 24 8.22 2249 3 3
4 13 1074.48 46 8.39 2145 3 3
5 13 645.12 46 9.18 1548 3 3
6 13 16.84 46 10.47 625 3 3
7 8 -0.04 150 10.51 590 3 3

Cycle 295 GMT 2/ 3/2024 6: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 32 10.48 704 3 3
2 3 955.68 -1 11.55 0 3 3
3 3 1021.24 1 8.91 2028 3 3
4 12 1196.24 5 8.24 2291 3 3
5 12 1730.64 50 7.28 3045 3 3
6 7 1724.16 24 7.28 3073 3 3
7 13 1596.64 46 7.63 2896 3 3
8 13 1028.64 46 8.55 2135 3 3
9 13 140.16 46 10.25 810 3 3
10 8 0.16 150 10.57 576 3 3

Cycle 294 GMT 1/ 3/2024 2:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 10.47 725 3 3
2 12 1183.04 50 8.15 2238 3 3
3 7 1179.92 24 8.27 2236 3 3
4 13 1069.72 46 8.44 2137 3 3
5 13 523.44 46 9.45 1374 3 3
6 13 17.64 46 10.48 621 3 3
7 8 0.04 150 10.53 580 3 3

Cycle 293 GMT 20/ 2/2024 7:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 30 10.50 708 3 3
2 12 1172.80 50 8.18 2261 3 3
3 7 1169.80 24 8.35 2231 3 3
4 13 1052.28 46 8.54 2102 3 3
5 13 504.24 46 9.51 1357 3 3
6 13 34.92 46 10.39 697 3 3
7 8 0.12 150 10.52 587 3 3

Cycle 292 GMT 10/ 2/2024 13:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 31 10.53 724 3 3
2 12 1183.28 50 8.20 2301 3 3
3 7 1180.48 24 8.39 2243 3 3
4 13 1070.56 46 8.55 2152 3 3
5 13 485.52 46 9.60 1313 3 3
6 13 16.56 46 10.53 620 3 3
7 8 0.00 150 10.56 582 3 3

Cycle 291 GMT 31/ 1/2024 19: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 32 10.50 728 3 3
2 3 969.08 -1 11.55 0 3 3
3 3 1033.28 1 8.94 2048 3 3
4 12 1193.60 5 8.50 2266 3 3
5 12 1746.28 50 7.47 3064 3 3
6 7 1739.92 24 7.64 3056 3 3
7 13 1610.44 46 7.72 2937 3 3
8 13 1029.48 46 8.70 2108 3 3
9 13 134.52 46 10.32 797 3 3
10 8 0.04 150 10.60 576 3 3

Cycle 290 GMT 30/ 1/2024 15:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 30 10.53 715 3 3
2 12 1200.04 50 8.30 2265 3 3
3 7 1197.00 24 8.05 2585 3 3
4 13 1086.40 46 8.59 2164 3 3
5 13 529.44 46 9.55 1378 3 3
6 8 0.12 150 10.59 583 3 3

Cycle 289 GMT 20/ 1/2024 20:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 30 10.54 717 3 3
2 12 1215.48 50 8.35 2262 3 3
3 7 1212.24 24 8.47 2276 3 3
4 13 1092.80 46 8.68 2117 3 3
5 13 516.00 46 9.62 1348 3 3
6 8 0.08 150 10.60 573 3 3

Cycle 288 GMT 11/ 1/2024 2:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 10.56 712 3 3
2 12 1165.52 50 8.47 2194 3 3
3 7 1162.72 24 8.60 2213 3 3
4 13 1056.32 46 8.76 2092 3 3
5 13 350.64 46 9.95 1103 3 3
6 8 0.04 150 10.61 568 3 3

Cycle 287 GMT 1/ 1/2024 8: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 32 10.52 712 3 3
2 3 955.88 -1 11.54 0 3 3
3 3 1022.48 1 9.03 2023 3 3
4 12 1180.36 5 8.60 2212 3 3
5 12 1737.64 50 7.57 3012 3 3
6 7 1730.72 24 7.70 3031 3 3
7 13 1595.56 46 7.93 2855 3 3
8 13 1003.20 46 8.88 2033 3 3
9 13 108.28 46 10.42 741 3 3
10 8 0.12 150 10.63 567 3 3

Cycle 286 GMT 31/12/2023 4:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 10.52 697 3 3
2 12 1183.64 50 8.39 2220 3 3
3 7 1180.88 24 8.53 2231 3 3
4 13 1069.52 46 8.67 2124 3 3
5 13 362.20 46 9.90 1128 3 3
6 8 0.12 150 10.60 569 3 3

Cycle 285 GMT 21/12/2023 10: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 29 10.52 710 3 3
2 3 1022.72 1 9.05 2010 3 3
3 3 1020.44 1 9.10 2011 3 3
4 12 1193.56 50 8.42 2211 3 3
5 7 1190.32 24 8.57 2217 3 3
6 13 1066.72 46 8.74 2083 3 3
7 13 360.16 46 9.95 1097 3 3
8 8 0.12 150 10.62 557 3 3

Cycle 284 GMT 11/12/2023 15:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 10.59 694 3 3
2 12 1181.56 50 8.47 2201 3 3
3 7 1178.64 24 8.58 2203 3 3
4 13 1062.56 46 8.73 2081 3 3
5 13 485.76 46 9.71 1279 3 3
6 8 -0.04 150 10.61 554 3 3

Cycle 283 GMT 1/12/2023 21:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 26 10.50 702 3 3
2 10 1055.32 3 8.92 2016 3 3
3 3 1076.88 2 8.93 2059 3 3
4 3 1050.52 1 8.94 2036 3 3
5 12 1187.84 5 8.67 2194 3 3
6 12 1741.52 50 7.52 2970 3 3
7 7 1734.92 24 7.54 2982 3 3
8 13 1610.36 46 7.72 2843 3 3
9 13 769.56 46 9.25 1694 3 3
10 13 169.96 46 10.32 815 3 3
11 8 0.08 150 10.63 553 3 3

Cycle 282 GMT 30/11/2023 17:37: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 24 10.70 663 3 3
2 10 1058.84 3 9.29 2028 3 3
3 3 1074.12 2 9.36 2023 3 3
4 3 1048.32 1 9.35 2019 3 3
5 12 1225.32 50 8.07 2203 3 3
6 7 1222.60 24 8.12 2218 3 3
7 13 1104.88 46 8.38 2101 3 3
8 13 545.32 46 9.54 1334 3 3
9 8 0.04 150 10.60 532 3 3

Cycle 281 GMT 20/11/2023 23: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 26 11.01 671 3 3
2 3 1080.36 2 10.15 2049 3 3
3 3 1039.56 1 10.23 1992 3 3
4 12 1196.68 50 9.23 2166 3 3
5 7 1192.52 24 9.07 2168 3 3
6 13 1064.64 46 9.02 2023 3 3
7 13 204.64 46 10.44 829 3 3
8 8 0.04 150 10.77 522 3 3

Cycle 280 GMT 11/11/2023 4:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 23 11.73 672 3 3
2 10 1016.40 3 11.25 1992 3 3
3 12 1197.04 50 8.78 2157 3 3
4 7 1192.88 24 9.12 2181 3 3
5 13 1070.96 46 9.19 2037 3 3
6 13 341.36 46 10.59 1027 3 3
7 8 -0.04 150 11.05 529 3 3

Cycle 279 GMT 1/11/2023 10:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 22 12.24 678 3 3
2 3 1121.56 3 11.66 2142 3 3
3 3 1051.32 1 11.74 2036 3 3
4 12 1188.16 5 11.59 2196 3 3
5 12 1697.48 50 10.25 2914 3 3
6 7 1688.84 24 10.21 2914 3 3
7 13 1093.84 46 10.35 2104 3 3
8 13 129.76 46 11.56 727 3 3
9 8 0.12 150 11.62 525 3 3

Cycle 278 GMT 31/10/2023 6:59: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 21 12.86 677 3 3
2 10 1000.92 3 12.44 1986 3 3
3 12 1217.44 50 6.82 2117 3 3
4 7 1218.56 24 9.59 2190 3 3
5 13 1125.48 46 9.47 2064 3 3
6 13 702.72 46 10.84 1538 3 3
7 8 0.16 150 12.15 528 3 3

Cycle 277 GMT 21/10/2023 12:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 21 13.46 690 3 3
2 3 1045.84 1 12.11 2033 3 3
3 3 1020.24 1 11.58 1946 3 3
4 12 1206.88 50 7.12 2121 3 3
5 7 1207.28 24 9.82 2193 3 3
6 13 1116.00 46 9.73 2081 3 3
7 13 546.80 46 11.60 1336 3 3
8 8 0.08 150 12.62 525 3 3

Cycle 276 GMT 11/10/2023 18: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 22 13.75 706 3 3
2 12 1190.04 50 8.92 2130 3 3
3 7 1186.80 24 10.52 2174 3 3
4 13 1057.92 46 10.64 2022 3 3
5 13 130.88 46 13.21 726 3 3
6 8 0.12 150 13.12 540 3 3

Cycle 275 GMT 1/10/2023 23:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 22 13.82 692 3 3
2 12 1174.88 5 11.62 2170 3 3
3 12 1690.68 50 10.40 2881 3 3
4 7 1682.16 24 10.73 2892 3 3
5 13 951.88 46 12.24 1906 3 3
6 13 53.72 46 13.67 625 3 3
7 8 0.12 150 13.34 547 3 3

Cycle 274 GMT 30/ 9/2023 20:38: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 21 13.99 694 3 3
2 12 1190.76 50 7.19 2063 3 3
3 7 1190.36 24 10.44 2179 3 3
4 13 1082.68 46 10.61 2054 3 3
5 13 338.44 46 13.08 1046 3 3
6 8 0.08 150 13.46 542 3 3

Cycle 273 GMT 21/ 9/2023 2:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 22 14.04 698 3 3
2 3 972.96 -1 15.06 0 3 3
3 12 1186.32 50 8.08 2096 3 3
4 7 1183.80 24 10.62 2166 3 3
5 13 1069.44 46 11.06 2009 3 3
6 13 171.64 46 13.57 794 3 3
7 8 0.04 150 13.59 544 3 3

Cycle 272 GMT 11/ 9/2023 7:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 21 14.07 719 3 3
2 3 1019.80 1 11.66 2003 3 3
3 12 1190.44 50 9.20 2124 3 3
4 7 1186.44 24 10.81 2171 3 3
5 13 1052.36 46 11.53 2029 3 3
6 13 106.92 46 13.74 693 3 3
7 8 0.00 150 13.67 542 3 3

Cycle 271 GMT 1/ 9/2023 13:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 22 14.04 722 3 3
2 12 1161.28 5 11.58 2176 3 3
3 12 1696.60 50 10.44 2899 3 3
4 7 1688.64 24 10.92 2894 3 3
5 13 948.24 46 12.56 1914 3 3
6 8 0.16 150 13.64 562 3 3

Cycle 270 GMT 31/ 8/2023 10:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 21 14.06 720 3 3
2 12 1203.80 50 7.37 2083 3 3
3 7 1203.84 24 10.72 2199 3 3
4 13 1104.72 46 11.40 2104 3 3
5 13 219.00 46 13.50 876 3 3
6 8 0.20 150 13.66 564 3 3

Cycle 269 GMT 21/ 8/2023 16: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 22 14.11 705 3 3
2 12 1169.80 50 8.28 2073 3 3
3 7 1168.40 24 10.78 2164 3 3
4 13 1061.48 46 11.57 2047 3 3
5 13 146.60 46 13.68 757 3 3
6 8 -0.08 150 13.71 568 3 3

Cycle 268 GMT 11/ 8/2023 21:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 21 14.08 712 3 3
2 12 1188.76 50 9.31 2118 3 3
3 7 1185.12 24 10.97 2189 3 3
4 13 1056.20 46 11.99 2045 3 3
5 13 51.96 46 13.88 629 3 3
6 8 0.16 150 13.76 562 3 3

Cycle 267 GMT 2/ 8/2023 3:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 21 14.08 704 3 3
2 12 1173.48 5 11.58 2189 3 3
3 12 1689.76 50 10.66 2894 3 3
4 7 1680.56 24 11.08 2905 3 3
5 13 923.44 46 12.71 1852 3 3
6 8 0.20 150 13.74 565 3 3

Cycle 266 GMT 1/ 8/2023 0:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 21 14.07 719 3 3
2 12 1197.96 50 7.23 2041 3 3
3 7 1198.16 24 10.87 2204 3 3
4 13 1097.24 46 11.70 2106 3 3
5 13 201.04 46 13.63 835 3 3
6 8 0.04 150 13.77 567 3 3

Cycle 265 GMT 22/ 7/2023 5:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 22 14.11 708 3 3
2 12 1175.76 50 7.42 2016 3 3
3 7 1176.00 24 10.99 2176 3 3
4 13 1071.24 46 11.85 2062 3 3
5 13 170.56 46 13.70 808 3 3
6 8 0.04 150 13.79 568 3 3

Cycle 264 GMT 12/ 7/2023 11:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 21 14.07 736 3 3
2 12 1196.72 50 9.14 2229 3 3
3 7 1192.96 24 11.28 2234 3 3
4 13 935.72 46 12.58 1916 3 3
5 13 57.72 46 13.90 659 3 3
6 8 0.04 150 13.80 576 3 3

Cycle 263 GMT 2/ 7/2023 17:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 21 14.08 725 3 3
2 12 1165.40 5 11.60 2190 3 3
3 12 1681.44 50 10.71 2905 3 3
4 7 1672.64 24 11.16 2903 3 3
5 13 917.32 46 12.76 1871 3 3
6 8 0.20 150 13.76 581 3 3

Cycle 262 GMT 1/ 7/2023 14: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 21 14.09 724 3 3
2 12 1185.76 50 7.46 2060 3 3
3 7 1186.48 24 11.02 2204 3 3
4 13 1086.40 46 11.90 2091 3 3
5 13 161.52 46 13.72 795 3 3
6 8 0.00 150 13.80 576 3 3

Cycle 261 GMT 21/ 6/2023 19:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 22 14.09 699 3 3
2 12 1166.48 50 7.78 2032 3 3
3 7 1165.92 24 11.12 2161 3 3
4 13 1054.24 46 12.01 2046 3 3
5 13 128.60 46 13.79 750 3 3
6 8 -0.08 150 13.83 572 3 3

Cycle 260 GMT 12/ 6/2023 1:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 22 14.09 706 3 3
2 12 1174.12 50 9.42 2099 3 3
3 7 1170.04 24 11.17 2196 3 3
4 13 906.92 46 12.55 1866 3 3
5 8 0.12 150 13.83 564 3 3

Cycle 259 GMT 2/ 6/2023 7:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 21 14.12 706 3 3
2 12 1162.40 5 11.64 2156 3 3
3 12 1681.16 50 10.77 2890 3 3
4 7 1672.92 24 11.19 2910 3 3
5 13 936.80 46 12.80 1875 3 3
6 8 0.16 150 13.86 565 3 3

Cycle 258 GMT 1/ 6/2023 4:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 21 14.07 732 3 3
2 12 1173.84 50 7.44 2030 3 3
3 7 1174.08 24 11.13 2182 3 3
4 13 1072.52 46 12.01 2090 3 3
5 13 167.60 46 13.76 795 3 3
6 8 0.12 150 13.84 577 3 3

Cycle 257 GMT 22/ 5/2023 9:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 22 14.11 710 3 3
2 3 967.84 -1 15.02 0 3 3
3 12 1210.48 50 7.96 2097 3 3
4 7 1208.40 24 11.19 2236 3 3
5 13 1091.36 46 12.13 2094 3 3
6 13 153.36 46 13.79 784 3 3
7 8 -0.04 150 13.84 581 3 3

Cycle 256 GMT 12/ 5/2023 15:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 21 14.12 702 3 3
2 3 1032.64 1 12.12 2024 3 3
3 12 1185.68 50 9.10 2136 3 3
4 7 1182.16 24 11.28 2186 3 3
5 13 1052.84 46 12.29 2038 3 3
6 13 54.32 46 13.94 652 3 3
7 8 0.00 150 13.87 582 3 3

Cycle 255 GMT 2/ 5/2023 21:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 22 14.08 713 3 3
2 12 1147.56 5 11.56 2147 3 3
3 12 1674.52 50 10.74 2886 3 3
4 7 1666.24 24 11.18 2913 3 3
5 13 784.60 46 12.99 1695 3 3
6 8 0.24 150 13.86 581 3 3

Cycle 254 GMT 1/ 5/2023 18: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 22 14.03 727 3 3
2 12 1164.80 50 7.14 2005 3 3
3 7 1165.84 24 11.14 2181 3 3
4 13 1067.60 46 12.04 2076 3 3
5 13 168.80 46 13.77 802 3 3
6 8 0.04 150 13.88 571 3 3

Cycle 253 GMT 21/ 4/2023 23:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 21 14.07 721 3 3
2 12 1200.40 50 7.62 2038 3 3
3 7 1199.68 24 11.25 2226 3 3
4 13 1079.96 46 12.17 2083 3 3
5 13 161.48 46 13.79 795 3 3
6 8 0.00 150 13.87 580 3 3

Cycle 252 GMT 12/ 4/2023 5:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 21 14.04 727 3 3
2 12 1155.64 50 9.31 2067 3 3
3 7 1151.92 24 11.35 2158 3 3
4 13 896.16 46 12.66 1857 3 3
5 13 30.64 46 13.98 619 3 3
6 8 0.08 150 13.90 586 3 3

Cycle 251 GMT 2/ 4/2023 11: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 21 14.03 718 3 3
2 12 1178.16 5 11.59 2178 3 3
3 12 1684.08 50 10.72 2888 3 3
4 7 1674.76 24 11.25 2892 3 3
5 13 903.60 46 12.89 1830 3 3
6 13 36.84 46 13.98 629 3 3
7 8 0.04 150 13.86 595 3 3

Cycle 250 GMT 1/ 4/2023 7:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 22 14.05 704 3 3
2 12 1165.44 50 6.80 1961 3 3
3 7 1167.84 24 11.18 2163 3 3
4 13 1075.44 46 12.09 2082 3 3
5 13 311.20 46 13.57 1024 3 3
6 8 -0.04 150 13.88 575 3 3

Cycle 249 GMT 22/ 3/2023 13:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 21 14.09 706 3 3
2 12 1157.84 50 7.52 1975 3 3
3 7 1157.52 24 11.31 2163 3 3
4 13 1050.32 46 12.27 2039 3 3
5 13 128.80 46 13.84 748 3 3
6 8 0.04 150 13.89 579 3 3

Cycle 248 GMT 12/ 3/2023 19:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 21 14.04 710 3 3
2 12 1177.80 50 8.88 2068 3 3
3 7 1174.80 24 11.39 2191 3 3
4 13 1044.84 46 12.36 2050 3 3
5 13 46.20 46 13.96 627 3 3
6 8 0.04 150 13.89 576 3 3

Cycle 247 GMT 3/ 3/2023 1:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 22 14.03 722 3 3
2 12 1147.80 5 11.56 2162 3 3
3 12 1685.92 50 10.66 2890 3 3
4 7 1678.28 24 11.21 2901 3 3
5 13 783.20 46 13.01 1696 3 3
6 8 0.12 150 13.89 585 3 3

Cycle 246 GMT 1/ 3/2023 21:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 22 14.04 713 3 3
2 12 1178.76 50 6.38 1935 3 3
3 7 1182.88 24 11.15 2196 3 3
4 13 1111.16 46 12.06 2117 3 3
5 13 241.32 46 13.68 923 3 3
6 8 0.00 150 13.88 585 3 3

Cycle 245 GMT 20/ 2/2023 3:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 21 14.00 721 3 3
2 12 1201.32 50 6.74 1975 3 3
3 7 1203.20 24 11.24 2208 3 3
4 13 1104.88 46 12.21 2111 3 3
5 13 217.48 46 13.74 866 3 3
6 8 0.04 150 13.91 569 3 3

Cycle 244 GMT 10/ 2/2023 9: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 22 14.01 707 3 3
2 3 973.20 -1 15.01 0 3 3
3 12 1173.12 50 8.62 2037 3 3
4 7 1170.60 24 11.46 2164 3 3
5 13 1047.96 46 12.48 1993 3 3
6 13 93.96 46 13.91 689 3 3
7 8 -0.08 150 13.89 573 3 3

Cycle 243 GMT 31/ 1/2023 14:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 22 13.98 704 3 3
2 12 1160.00 5 11.54 2145 3 3
3 12 1675.88 50 10.60 2864 3 3
4 7 1666.76 24 11.23 2871 3 3
5 13 901.76 46 12.90 1814 3 3
6 13 23.16 46 14.00 604 3 3
7 8 0.12 150 13.93 572 3 3

Cycle 242 GMT 30/ 1/2023 11:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 23 14.02 695 3 3
2 3 964.48 -1 15.02 0 3 3
3 12 1199.92 50 6.08 1892 3 3
4 7 1203.48 24 11.14 2211 3 3
5 13 1124.84 46 12.12 2109 3 3
6 13 409.00 46 13.47 1154 3 3
7 8 0.00 150 13.92 568 3 3

Cycle 241 GMT 20/ 1/2023 17:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 22 14.02 699 3 3
2 3 967.80 -1 15.02 0 3 3
3 3 1022.32 1 11.45 2027 3 3
4 12 1200.04 50 6.52 1929 3 3
5 7 1203.00 24 11.33 2207 3 3
6 13 1105.20 46 12.29 2091 3 3
7 13 215.32 46 13.77 853 3 3
8 8 0.16 150 13.94 572 3 3

Cycle 240 GMT 10/ 1/2023 22:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 22 13.96 711 3 3
2 12 1172.56 50 8.41 2042 3 3
3 7 1170.20 24 11.47 2160 3 3
4 13 1053.76 46 12.40 2049 3 3
5 13 104.96 46 13.90 698 3 3
6 8 -0.04 150 13.92 570 3 3

Cycle 239 GMT 1/ 1/2023 4:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 22 14.02 682 3 3
2 12 1177.80 5 11.44 2159 3 3
3 12 1691.36 50 10.53 2868 3 3
4 7 1683.20 24 11.24 2875 3 3
5 13 1068.00 46 12.70 2052 3 3
6 13 18.60 46 14.02 576 3 3
7 8 0.16 150 13.91 572 3 3

Cycle 238 GMT 31/12/2022 1:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 22 13.99 697 3 3
2 12 1199.88 50 6.02 1881 3 3
3 7 1204.36 24 11.21 2193 3 3
4 13 1136.40 46 12.15 2112 3 3
5 13 555.96 46 13.30 1341 3 3
6 8 0.08 150 13.95 549 3 3

Cycle 237 GMT 21/12/2022 6:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 23 13.97 714 3 3
2 3 971.24 -1 15.04 0 3 3
3 12 1200.12 50 6.42 1908 3 3
4 7 1202.96 24 11.34 2196 3 3
5 13 1109.56 46 12.32 2076 3 3
6 13 232.16 46 13.74 877 3 3
7 8 0.04 150 13.96 555 3 3

Cycle 236 GMT 11/12/2022 12:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 22 13.94 716 3 3
2 3 1023.48 1 11.97 2010 3 3
3 3 1019.60 1 11.38 1978 3 3
4 12 1200.92 50 8.20 2051 3 3
5 7 1199.64 24 11.51 2204 3 3
6 13 1092.28 46 12.47 2085 3 3
7 13 74.96 46 13.93 659 3 3
8 8 0.00 150 13.92 571 3 3

Cycle 235 GMT 1/12/2022 17:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 22 13.98 705 3 3
2 3 970.44 -1 15.05 0 3 3
3 3 1025.84 1 11.51 1976 3 3
4 12 1170.52 5 11.54 2166 3 3
5 12 1694.08 50 10.57 2881 3 3
6 7 1685.88 24 11.22 2907 3 3
7 13 808.16 46 12.99 1717 3 3
8 8 0.16 150 13.93 572 3 3

Cycle 234 GMT 30/11/2022 14:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 22 13.97 691 3 3
2 12 1181.32 50 5.95 1847 3 3
3 7 1184.52 24 11.20 2163 3 3
4 13 1106.84 46 12.20 2090 3 3
5 13 401.76 46 13.50 1122 3 3
6 8 0.00 150 13.94 563 3 3

Cycle 233 GMT 20/11/2022 20:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 21 13.96 676 3 3
2 12 1213.48 50 6.08 1890 3 3
3 7 1217.08 24 11.26 2214 3 3
4 13 1144.76 46 12.24 2122 3 3
5 13 428.12 46 13.48 1158 3 3
6 8 0.04 150 13.95 553 3 3

Cycle 232 GMT 11/11/2022 1:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 21 13.92 706 3 3
2 12 1158.60 50 8.31 2007 3 3
3 7 1156.40 24 11.55 2129 3 3
4 13 1037.64 46 12.47 2015 3 3
5 13 52.96 46 13.94 627 3 3
6 8 0.08 150 13.92 568 3 3

Cycle 231 GMT 1/11/2022 7:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 22 13.95 702 3 3
2 3 1021.12 1 10.68 2023 3 3
3 12 1189.00 5 11.42 2196 3 3
4 12 1691.24 50 10.44 2880 3 3
5 7 1683.24 24 11.21 2919 3 3
6 13 932.60 46 12.84 1853 3 3
7 13 39.00 46 13.94 614 3 3
8 8 -0.04 150 13.88 570 3 3

Cycle 230 GMT 31/10/2022 4:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 22 13.91 703 3 3
2 12 1165.88 50 5.79 1797 3 3
3 7 1171.24 24 11.09 2157 3 3
4 13 1133.44 46 12.02 2134 3 3
5 13 563.56 46 13.23 1368 3 3
6 8 0.08 150 13.91 560 3 3

Cycle 229 GMT 21/10/2022 9:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 23 13.94 688 3 3
2 3 954.88 -1 15.08 0 3 3
3 12 1168.60 50 5.92 1828 3 3
4 7 1173.36 24 11.23 2151 3 3
5 13 1114.84 46 12.13 2106 3 3
6 13 535.84 46 13.29 1319 3 3
7 8 -0.04 150 13.89 560 3 3

Cycle 228 GMT 11/10/2022 15:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 21 13.95 698 3 3
2 3 1024.28 1 11.79 1960 3 3
3 3 1019.08 1 11.26 1986 3 3
4 12 1194.92 50 7.76 2040 3 3
5 7 1193.88 24 11.52 2176 3 3
6 13 1080.52 46 12.47 2057 3 3
7 13 71.16 46 13.91 643 3 3
8 8 0.12 150 13.92 560 3 3

Cycle 227 GMT 1/10/2022 21:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 22 13.90 698 3 3
2 12 1165.36 5 11.39 2159 3 3
3 12 1696.60 50 10.27 2886 3 3
4 7 1688.80 24 11.21 2903 3 3
5 13 850.48 46 12.92 1766 3 3
6 8 0.16 150 13.91 559 3 3

Cycle 226 GMT 30/ 9/2022 17:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 22 13.90 709 3 3
2 12 1171.12 50 5.68 1796 3 3
3 7 1176.08 24 11.09 2148 3 3
4 13 1132.16 46 12.03 2115 3 3
5 13 582.44 46 13.20 1383 3 3
6 8 0.04 150 13.91 556 3 3

Cycle 225 GMT 20/ 9/2022 23:30: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 22 13.92 705 3 3
2 3 959.80 -1 15.10 0 3 3
3 12 1185.48 50 5.88 1849 3 3
4 7 1189.44 24 11.19 2174 3 3
5 13 1128.76 46 12.16 2121 3 3
6 13 551.60 46 13.25 1348 3 3
7 8 0.12 150 13.89 566 3 3

Cycle 224 GMT 11/ 9/2022 5: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 22 13.92 699 3 3
2 12 1187.68 50 7.64 2018 3 3
3 7 1186.84 24 11.52 2172 3 3
4 13 1073.04 46 12.46 2054 3 3
5 13 65.24 46 13.91 640 3 3
6 8 0.08 150 13.89 567 3 3

Cycle 223 GMT 1/ 9/2022 10:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 22 13.90 702 3 3
2 12 1173.24 5 11.21 2171 3 3
3 12 1690.60 50 10.22 2866 3 3
4 7 1682.44 24 11.19 2914 3 3
5 13 952.12 46 12.79 1890 3 3
6 8 0.36 150 13.88 565 3 3

Cycle 222 GMT 31/ 8/2022 7:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 22 13.90 699 3 3
2 12 1189.24 50 5.78 1852 3 3
3 7 1194.32 24 11.11 2155 3 3
4 13 1143.76 46 12.05 2131 3 3
5 13 587.04 46 13.18 1391 3 3
6 8 0.08 150 13.89 552 3 3

Cycle 221 GMT 21/ 8/2022 13: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 22 13.92 685 3 3
2 3 965.64 -1 15.11 0 3 3
3 3 1021.60 1 10.97 1970 3 3
4 12 1191.48 50 5.85 1867 3 3
5 7 1195.56 24 11.19 2176 3 3
6 13 1127.44 46 12.21 2101 3 3
7 13 436.20 46 13.39 1188 3 3
8 8 0.04 150 13.87 562 3 3

Cycle 220 GMT 11/ 8/2022 18:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 21 13.88 697 3 3
2 3 1023.44 1 11.75 1960 3 3
3 12 1215.92 50 7.55 2061 3 3
4 7 1215.96 24 11.46 2209 3 3
5 13 1109.24 46 12.37 2107 3 3
6 13 165.12 46 13.75 773 3 3
7 8 0.00 150 13.88 556 3 3

Cycle 219 GMT 2/ 8/2022 0:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 22 13.91 684 3 3
2 12 1168.48 5 11.31 2119 3 3
3 12 1688.56 50 10.25 2854 3 3
4 7 1680.16 24 11.22 2876 3 3
5 13 947.76 46 12.80 1863 3 3
6 8 0.16 150 13.91 558 3 3

Cycle 218 GMT 31/ 7/2022 20:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 22 13.90 705 3 3
2 12 1173.40 50 5.65 1819 3 3
3 7 1179.00 24 11.01 2145 3 3
4 13 1201.16 46 11.82 2213 3 3
5 13 793.32 46 12.86 1673 3 3
6 8 0.00 150 13.89 554 3 3

Cycle 217 GMT 22/ 7/2022 2:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 21 13.85 717 3 3
2 12 1172.72 50 5.78 1854 3 3
3 7 1177.16 24 11.08 2148 3 3
4 13 1124.68 46 12.03 2118 3 3
5 13 570.56 46 13.16 1369 3 3
6 8 0.00 150 13.87 556 3 3

Cycle 216 GMT 12/ 7/2022 7:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 22 13.93 698 3 3
2 12 1161.56 50 7.52 2013 3 3
3 7 1160.96 24 11.47 2144 3 3
4 13 1050.28 46 12.35 2031 3 3
5 13 131.12 46 13.78 734 3 3
6 8 -0.08 150 13.88 560 3 3

Cycle 215 GMT 2/ 7/2022 13:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 21 13.87 696 3 3
2 12 1164.08 5 11.33 2119 3 3
3 12 1686.72 50 10.16 2850 3 3
4 7 1678.60 24 11.23 2889 3 3
5 13 939.88 46 12.81 1856 3 3
6 13 24.16 46 13.93 596 3 3
7 8 0.12 150 13.88 567 3 3

Cycle 214 GMT 1/ 7/2022 10:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 22 13.87 694 3 3
2 12 1178.56 50 5.73 1862 3 3
3 7 1183.84 24 10.98 2148 3 3
4 13 1147.60 46 11.93 2144 3 3
5 13 727.40 46 12.93 1600 3 3
6 8 0.12 150 13.87 560 3 3

Cycle 213 GMT 21/ 6/2022 16: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 22 13.87 686 3 3
2 3 968.20 -1 15.15 0 3 3
3 3 1021.68 1 10.84 1982 3 3
4 12 1191.24 50 5.87 1911 3 3
5 7 1195.52 24 11.06 2170 3 3
6 13 1130.20 46 12.14 2098 3 3
7 13 551.08 46 13.21 1337 3 3
8 8 0.08 150 13.84 562 3 3

Cycle 212 GMT 11/ 6/2022 21:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 21 13.93 698 3 3
2 3 1021.68 1 11.41 1970 3 3
3 12 1194.16 50 7.08 2022 3 3
4 7 1194.92 24 11.38 2181 3 3
5 13 1093.88 46 12.28 2089 3 3
6 13 176.56 46 13.70 795 3 3
7 8 0.04 150 13.85 563 3 3

Cycle 211 GMT 2/ 6/2022 3:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 22 13.87 696 3 3
2 12 1149.64 5 11.12 2143 3 3
3 12 1682.12 50 10.01 2833 3 3
4 7 1674.04 24 11.27 2855 3 3
5 13 937.24 46 12.77 1864 3 3
6 8 0.16 150 13.87 564 3 3

Cycle 210 GMT 1/ 6/2022 0: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 23 13.85 702 3 3
2 3 973.56 -1 15.16 0 3 3
3 12 1184.00 50 5.81 1882 3 3
4 7 1187.88 24 10.95 2150 3 3
5 13 1128.16 46 12.03 2109 3 3
6 13 560.52 46 13.16 1352 3 3
7 8 -0.04 150 13.85 556 3 3

Cycle 209 GMT 22/ 5/2022 5:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 21 13.89 688 3 3
2 12 1151.36 50 5.96 1890 3 3
3 7 1155.04 24 11.02 2099 3 3
4 13 1097.72 46 11.98 2052 3 3
5 13 398.24 46 13.36 1113 3 3
6 8 0.00 150 13.84 551 3 3

Cycle 208 GMT 12/ 5/2022 11:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 22 13.87 691 3 3
2 12 1165.08 50 7.24 2023 3 3
3 7 1165.08 24 11.38 2129 3 3
4 13 1060.72 46 12.26 2023 3 3
5 13 140.32 46 13.74 731 3 3
6 8 -0.08 150 13.87 544 3 3

Cycle 207 GMT 2/ 5/2022 16:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 21 13.91 674 3 3
2 12 1175.48 5 11.19 2140 3 3
3 12 1680.96 50 10.05 2835 3 3
4 7 1673.28 24 11.25 2858 3 3
5 13 948.48 46 12.76 1883 3 3
6 13 47.60 46 13.88 615 3 3
7 8 0.08 150 13.88 561 3 3

Cycle 206 GMT 1/ 5/2022 13:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 24 13.90 691 3 3
2 3 938.04 -1 15.18 0 3 3
3 12 1167.08 50 5.78 1895 3 3
4 7 1171.12 24 10.83 2126 3 3
5 13 1115.08 46 11.90 2077 3 3
6 13 689.36 46 12.95 1529 3 3
7 8 0.08 150 13.87 548 3 3

Cycle 205 GMT 21/ 4/2022 19:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 21 13.90 683 3 3
2 12 1177.08 50 6.07 1956 3 3
3 7 1180.04 24 10.99 2150 3 3
4 13 1109.52 46 12.01 2076 3 3
5 13 530.44 46 13.20 1305 3 3
6 8 0.04 150 13.85 554 3 3

Cycle 204 GMT 12/ 4/2022 1: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 22 13.89 689 3 3
2 12 1158.96 50 7.32 2046 3 3
3 7 1159.20 24 11.36 2144 3 3
4 13 1048.52 46 12.22 2014 3 3
5 13 133.60 46 13.74 726 3 3
6 8 0.04 150 13.86 551 3 3

Cycle 203 GMT 2/ 4/2022 6:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 22 13.93 675 3 3
2 3 965.36 -1 15.20 0 3 3
3 12 1171.64 5 11.11 2126 3 3
4 12 1677.80 50 9.89 2838 3 3
5 7 1670.04 24 11.24 2863 3 3
6 13 1105.68 46 12.60 2082 3 3
7 13 48.40 46 13.89 604 3 3
8 8 -0.04 150 13.91 552 3 3

Cycle 202 GMT 1/ 4/2022 3:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1005.28 8 12.79 1954 3 3
2 10 1070.16 6 13.00 2067 3 3
3 10 1124.76 5 12.99 2150 3 3
4 3 1125.52 3 12.98 2143 3 3
5 3 1168.08 4 12.49 2195 3 3
6 12 1217.88 50 5.75 1937 3 3
7 7 1222.68 24 10.61 2177 3 3
8 13 1187.80 46 11.75 2176 3 3
9 13 777.76 46 12.88 1636 3 3
10 13 17.04 46 13.90 566 3 3
11 8 0.08 150 13.88 553 3 3

Cycle 201 GMT 22/ 3/2022 12:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 22 13.92 674 3 3
2 12 1181.40 50 6.37 2016 3 3
3 7 1184.36 24 10.82 2146 3 3
4 13 1102.84 46 11.78 2075 3 3
5 13 364.76 46 13.38 1070 3 3
6 8 0.00 150 13.84 550 3 3

Cycle 200 GMT 12/ 3/2022 18:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 22 13.95 682 3 3
2 3 972.24 -1 15.23 0 3 3
3 3 1020.48 1 10.88 1949 3 3
4 12 1190.44 50 7.82 2079 3 3
5 7 1187.48 24 11.28 2158 3 3
6 13 1062.40 46 12.14 2022 3 3
7 13 132.72 46 13.75 700 3 3
8 8 0.08 150 13.90 532 3 3

Cycle 199 GMT 3/ 3/2022 0:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 24 13.95 667 3 3
2 3 923.56 -1 15.24 0 3 3
3 3 970.52 -1 15.24 0 3 3
4 12 1186.36 5 11.31 2158 3 3
5 12 1689.24 50 10.24 2844 3 3
6 7 1681.12 24 11.20 2862 3 3
7 13 941.72 46 12.84 1859 3 3
8 13 46.76 46 13.91 594 3 3
9 8 0.04 150 13.93 559 3 3

Cycle 198 GMT 1/ 3/2022 21: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 22 13.93 684 3 3
2 12 2007.24 200 5.74 2772 3 3
3 7 2009.44 24 10.25 3290 3 3
4 13 1933.00 46 11.36 3160 3 3
5 13 1380.28 46 12.35 2451 3 3
6 13 148.32 46 13.77 730 3 3
7 8 0.08 150 13.98 532 3 3

Cycle 197 GMT 19/ 2/2022 21:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 22 13.93 678 3 3
2 12 2009.28 200 5.75 2808 3 3
3 7 2011.40 24 10.25 3250 3 3
4 13 1928.80 46 11.20 3141 3 3
5 13 1369.04 46 12.22 2439 3 3
6 13 255.76 46 13.60 897 3 3
7 8 0.08 150 13.95 534 3 3

Cycle 196 GMT 9/ 2/2022 22: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 22 13.94 661 3 3
2 12 1170.88 1 5.83 1872 3 3
3 12 1815.00 150 5.76 2753 3 3
4 12 1807.96 100 6.56 2974 3 3
5 7 1801.04 24 10.59 3018 3 3
6 13 1079.28 46 12.52 2057 3 3
7 13 123.64 46 13.78 693 3 3
8 8 -0.04 150 13.92 550 3 3

Cycle 195 GMT 30/ 1/2022 21:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 21 13.90 695 3 3
2 12 1180.76 1 5.83 1857 3 3
3 12 1808.20 150 5.77 2719 3 3
4 12 1799.48 100 6.49 2956 3 3
5 7 1792.20 24 10.52 3029 3 3
6 13 1067.48 46 12.56 2035 3 3
7 13 103.96 46 13.79 678 3 3
8 8 -0.04 150 13.93 548 3 3

Cycle 194 GMT 20/ 1/2022 22: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 22 13.87 684 3 3
2 12 1170.68 1 5.86 1800 3 3
3 12 1800.60 150 5.71 2599 3 3
4 12 1795.20 100 6.31 2951 3 3
5 7 1788.44 24 10.55 3025 3 3
6 13 1361.76 46 12.23 2432 3 3
7 13 124.36 46 13.77 700 3 3
8 8 0.12 150 13.95 541 3 3

Cycle 193 GMT 10/ 1/2022 22: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 22 13.97 671 3 3
2 12 1180.28 1 5.83 1897 3 3
3 12 1335.44 150 7.32 2299 3 3
4 12 1309.36 100 7.83 2363 3 3
5 7 1297.12 24 11.03 2355 3 3
6 8 0.04 150 13.88 533 3 3

Cycle 192 GMT 1/ 1/2022 0: 5: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 22 13.93 685 3 3
2 3 958.04 -1 15.26 0 3 3
3 12 2004.36 20 11.25 488 3 3
4 12 2009.72 200 5.80 3101 3 3
5 7 2010.88 43 9.87 3255 3 3
6 13 1896.24 46 11.64 3122 3 3
7 13 1004.36 46 12.79 1924 3 3
8 13 72.88 46 13.90 627 3 3
9 8 0.00 150 13.99 540 3 3

Cycle 191 GMT 22/12/2021 0:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 22 13.93 685 3 3
2 12 2010.16 20 11.27 484 3 3
3 12 2021.20 200 5.81 3086 3 3
4 7 2023.48 43 9.78 3315 3 3
5 13 1915.24 46 11.61 3148 3 3
6 13 1144.40 46 12.63 2136 3 3
7 13 32.48 46 13.94 588 3 3
8 8 -0.04 150 14.01 549 3 3

Cycle 190 GMT 12/12/2021 1:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 23 13.93 688 3 3
2 3 965.64 -1 15.26 0 3 3
3 3 1023.72 1 11.16 1942 3 3
4 12 2002.56 20 11.33 488 3 3
5 12 2009.76 200 5.82 3099 3 3
6 7 2011.28 43 9.83 3273 3 3
7 13 1894.28 46 11.65 3127 3 3
8 13 1019.44 46 12.77 1959 3 3
9 8 -0.04 150 13.99 540 3 3

Cycle 189 GMT 2/12/2021 1:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 21 13.98 666 3 3
2 3 1029.76 1 11.66 1950 3 3
3 3 1020.88 1 11.05 1938 3 3
4 12 2006.36 20 11.40 489 3 3
5 12 2013.16 200 5.94 3175 3 3
6 7 2012.60 43 9.90 3305 3 3
7 13 1887.16 46 11.67 3131 3 3
8 13 806.84 46 12.99 1675 3 3
9 8 0.04 150 13.97 541 3 3

Cycle 188 GMT 22/11/2021 2:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 22 13.92 689 3 3
2 3 965.72 -1 15.27 0 3 3
3 3 1018.80 1 11.21 1954 3 3
4 12 2003.52 20 11.32 488 3 3
5 12 2009.64 200 5.89 3175 3 3
6 7 2009.68 43 9.94 3269 3 3
7 13 1884.68 44 11.71 3120 3 3
8 13 839.64 44 12.94 1726 3 3
9 8 0.08 150 13.97 532 3 3

Cycle 187 GMT 12/11/2021 2:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 22 13.98 667 3 3
2 3 973.52 -1 15.27 0 3 3
3 3 1032.40 1 11.42 1945 3 3
4 12 2001.20 20 11.39 476 3 3
5 12 2008.40 200 5.90 3210 3 3
6 7 2008.72 43 9.97 3276 3 3
7 13 1880.68 44 11.73 3118 3 3
8 13 845.08 44 12.95 1724 3 3
9 13 18.16 44 13.98 549 3 3
10 8 -0.04 150 13.99 547 3 3

Cycle 186 GMT 2/11/2021 3:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 21 13.96 681 3 3
2 3 1022.68 1 11.00 1911 3 3
3 12 2002.48 20 11.21 480 3 3
4 12 2010.96 200 5.81 3131 3 3
5 7 2012.84 43 9.94 3289 3 3
6 13 1915.72 44 11.66 3154 3 3
7 13 1150.28 44 12.69 2121 3 3
8 13 70.40 44 13.92 608 3 3
9 8 -0.08 150 13.99 542 3 3

Cycle 185 GMT 23/10/2021 4:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 21 13.96 675 3 3
2 12 2005.72 20 11.28 481 3 3
3 12 2014.44 200 6.03 3228 3 3
4 7 2012.68 43 9.97 3322 3 3
5 13 1878.08 44 11.71 3112 3 3
6 13 782.68 44 13.01 1650 3 3
7 8 0.12 150 13.98 541 3 3

Cycle 184 GMT 13/10/2021 5:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 22 13.98 680 3 3
2 12 2003.72 20 11.10 485 3 3
3 12 2010.84 200 5.91 3209 3 3
4 7 2010.48 24 10.63 3345 3 3
5 13 1912.88 46 11.67 3158 3 3
6 13 1466.80 46 12.39 2562 3 3
7 13 244.92 46 13.66 877 3 3
8 8 0.12 150 13.97 544 3 3

Cycle 183 GMT 3/10/2021 6: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 22 13.96 677 3 3
2 12 2006.12 20 10.89 474 3 3
3 12 2013.20 200 5.90 3181 3 3
4 7 2013.12 24 10.67 3318 3 3
5 13 1918.44 46 11.65 3148 3 3
6 13 1316.52 46 12.53 2360 3 3
7 13 138.08 46 13.82 699 3 3
8 8 0.08 150 13.99 530 3 3

Cycle 182 GMT 23/ 9/2021 6:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 22 13.96 675 3 3
2 12 2005.76 20 10.84 452 3 3
3 12 2012.52 200 5.78 3015 3 3
4 7 2014.00 24 10.58 3312 3 3
5 13 1927.84 34 11.90 3164 3 3
6 13 1640.96 34 12.50 2778 3 3
7 13 855.56 34 13.17 1712 3 3
8 13 100.08 34 13.91 641 3 3
9 8 -0.08 150 14.01 528 3 3

Cycle 181 GMT 13/ 9/2021 7:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 21 13.96 666 3 3
2 3 1023.24 1 11.13 1926 3 3
3 3 1025.16 1 10.66 1929 3 3
4 12 2000.68 20 10.62 461 3 3
5 12 2008.56 200 5.74 2831 3 3
6 7 2010.28 24 10.64 3279 3 3
7 13 1937.24 34 11.87 3152 3 3
8 13 1806.60 34 12.27 2989 3 3
9 13 1013.68 34 13.01 1938 3 3
10 13 78.32 34 13.91 626 3 3
11 8 0.04 150 14.02 521 3 3

Cycle 180 GMT 3/ 9/2021 7:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 22 14.00 662 3 3
2 3 962.84 -1 15.28 0 3 3
3 12 1185.92 1 5.78 1674 3 3
4 12 1790.52 150 6.44 2810 3 3
5 12 1770.24 70 6.99 2979 3 3
6 7 1761.60 24 11.01 2969 3 3
7 13 347.80 34 13.52 1011 3 3
8 8 0.00 150 13.91 531 3 3

Cycle 179 GMT 24/ 8/2021 8:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 22 14.02 668 3 3
2 12 1169.00 1 5.75 1596 3 3
3 12 1798.28 150 5.73 2631 3 3
4 12 1796.96 70 6.12 2916 3 3
5 7 1793.12 24 10.95 3021 3 3
6 13 1660.80 34 12.37 2825 3 3
7 13 1184.84 34 12.95 2169 3 3
8 13 161.36 34 13.82 723 3 3
9 8 -0.04 150 14.01 518 3 3
10 14 -0.04 40 14.13 531 3 3

Cycle 178 GMT 14/ 8/2021 8:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 23 14.03 651 3 3
2 3 949.68 -1 15.27 0 3 3
3 12 2010.04 150 5.69 2475 3 3
4 7 2011.80 24 10.52 3248 3 3
5 13 1937.72 34 11.97 3183 3 3
6 13 1810.72 34 12.36 3001 3 3
7 13 1000.08 34 13.07 1899 3 3
8 13 148.64 34 13.87 703 3 3
9 8 0.12 150 14.02 515 3 3

Cycle 177 GMT 4/ 8/2021 8:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 21 14.00 676 3 3
2 3 1045.32 1 11.72 1965 3 3
3 3 1021.76 1 10.80 1898 3 3
4 12 2008.72 150 5.63 2185 3 3
5 7 2010.56 24 10.33 3219 3 3
6 13 1933.88 34 11.97 3134 3 3
7 13 1793.56 34 12.37 2967 3 3
8 13 1140.36 34 12.97 2093 3 3
9 13 137.16 34 13.88 689 3 3
10 8 0.00 150 14.03 506 3 3

Cycle 176 GMT 25/ 7/2021 9:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 22 14.01 684 3 3
2 3 949.72 -1 15.25 0 3 3
3 12 1106.72 3 5.64 1471 3 3
4 12 1778.96 100 5.65 2128 3 3
5 7 1778.44 24 10.36 2934 3 3
6 13 1676.32 34 12.15 2818 3 3
7 13 1396.48 34 12.67 2464 3 3
8 13 432.68 34 13.51 1133 3 3
9 8 0.04 150 13.96 516 3 3

Cycle 175 GMT 15/ 7/2021 9:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 22 14.02 665 3 3
2 12 1116.76 3 5.67 1448 3 3
3 12 1787.20 100 5.61 1979 3 3
4 7 1787.20 24 10.43 2925 3 3
5 13 1699.24 34 12.28 2833 3 3
6 13 1409.08 34 12.72 2473 3 3
7 13 609.20 34 13.37 1389 3 3
8 13 22.92 34 14.02 552 3 3
9 8 0.00 150 14.00 524 3 3

Cycle 174 GMT 5/ 7/2021 9:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 22 14.07 653 3 3
2 12 2005.76 54 5.61 1760 3 3
3 7 2007.04 24 8.83 3176 3 3
4 13 1987.72 34 11.56 3202 3 3
5 13 1869.20 34 12.07 3096 3 3
6 13 1407.76 34 12.69 2462 3 3
7 13 567.24 34 13.39 1335 3 3
8 8 0.00 150 13.95 528 3 3

Cycle 173 GMT 25/ 6/2021 10: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 22 14.06 648 3 3
2 12 2004.60 54 5.62 1758 3 3
3 7 2005.44 24 8.86 3182 3 3
4 13 1973.04 34 11.72 3170 3 3
5 13 1851.16 34 12.16 3053 3 3
6 13 1384.96 34 12.74 2417 3 3
7 13 264.20 34 13.70 883 3 3
8 8 0.12 150 13.97 515 3 3

Cycle 172 GMT 15/ 6/2021 10:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 22 14.06 657 3 3
2 12 2005.00 54 5.60 1730 3 3
3 7 2006.16 24 8.66 3185 3 3
4 13 1982.92 34 11.61 3197 3 3
5 13 1865.96 34 12.09 3091 3 3
6 13 1413.28 34 12.68 2496 3 3
7 13 413.84 34 13.53 1122 3 3
8 8 -0.12 150 13.98 519 3 3

Cycle 171 GMT 5/ 6/2021 10:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 22 14.07 650 3 3
2 12 2006.16 54 5.62 1752 3 3
3 7 2007.08 24 8.90 3181 3 3
4 13 1976.20 34 11.70 3181 3 3
5 13 1860.80 34 12.15 3056 3 3
6 13 1127.72 34 12.94 2084 3 3
7 13 321.28 34 13.64 974 3 3
8 8 0.04 150 13.99 513 3 3

Cycle 170 GMT 26/ 5/2021 11: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 22 14.04 670 3 3
2 12 2004.48 54 5.61 1738 3 3
3 7 2005.60 24 8.91 3179 3 3
4 13 1973.92 34 11.77 3188 3 3
5 13 1852.04 34 12.22 3040 3 3
6 13 1403.60 34 12.73 2461 3 3
7 13 281.68 34 13.70 905 3 3
8 8 0.00 150 14.00 511 3 3

Cycle 169 GMT 16/ 5/2021 11:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 22 14.09 652 3 3
2 12 2007.88 54 5.62 1788 3 3
3 7 2008.84 24 9.22 3179 3 3
4 13 1974.40 34 11.83 3165 3 3
5 13 1857.56 34 12.23 3045 3 3
6 13 1250.88 34 12.86 2257 3 3
7 13 424.88 34 13.56 1111 3 3
8 8 -0.04 150 13.98 522 3 3

Cycle 168 GMT 6/ 5/2021 11:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 22 14.12 652 3 3
2 12 2004.68 54 5.64 1800 3 3
3 7 2005.64 24 9.26 3173 3 3
4 13 1967.32 34 11.85 3166 3 3
5 13 1841.08 34 12.26 3037 3 3
6 13 1243.68 34 12.88 2237 3 3
7 13 265.48 34 13.73 877 3 3
8 8 0.08 150 14.02 509 3 3

Cycle 167 GMT 26/ 4/2021 12: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 21 14.09 649 3 3
2 12 2006.40 54 5.64 1849 3 3
3 7 2007.56 24 9.55 3192 3 3
4 13 1965.96 34 12.01 3171 3 3
5 13 1836.04 34 12.34 3044 3 3
6 13 1101.96 34 13.01 2043 3 3
7 13 163.80 34 13.88 736 3 3
8 8 0.08 150 14.02 514 3 3

Cycle 166 GMT 16/ 4/2021 12:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 22 14.11 644 3 3
2 3 971.56 -1 15.26 0 3 3
3 3 1023.48 1 11.63 1921 3 3
4 12 2014.40 54 5.64 1852 3 3
5 7 2015.72 24 9.60 3216 3 3
6 13 1986.00 34 12.01 3196 3 3
7 13 1861.44 34 12.35 3051 3 3
8 13 1079.52 34 13.02 2031 3 3
9 13 148.12 34 13.90 700 3 3
10 8 0.08 150 14.03 503 3 3

Cycle 165 GMT 6/ 4/2021 12:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 21 14.13 652 3 3
2 12 2005.80 54 5.65 1894 3 3
3 7 2006.76 24 9.85 3189 3 3
4 13 1954.32 34 12.15 3139 3 3
5 13 1824.32 34 12.40 3010 3 3
6 13 1211.36 34 12.95 2189 3 3
7 13 129.88 34 13.95 670 3 3
8 8 0.00 150 14.05 498 3 3

Cycle 164 GMT 27/ 3/2021 13: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 21 14.13 638 3 3
2 12 2007.32 54 5.63 1853 3 3
3 7 2008.36 24 9.60 3193 3 3
4 13 1965.40 34 12.03 3163 3 3
5 13 1848.40 34 12.39 3025 3 3
6 13 1239.72 34 12.93 2229 3 3
7 13 255.96 34 13.77 866 3 3
8 8 0.08 150 14.02 509 3 3

Cycle 163 GMT 17/ 3/2021 13:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 21 14.16 643 3 3
2 12 2004.44 54 5.66 1929 3 3
3 7 2005.28 24 9.91 3206 3 3
4 13 1952.60 34 12.11 3176 3 3
5 13 1839.96 34 12.40 3018 3 3
6 13 1214.28 34 12.97 2192 3 3
7 13 223.32 34 13.83 811 3 3
8 8 0.04 150 14.04 510 3 3

Cycle 162 GMT 7/ 3/2021 14:10: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 21 14.13 643 3 3
2 12 2003.56 54 5.66 1969 3 3
3 7 2004.80 24 10.01 3190 3 3
4 13 1950.60 34 12.10 3178 3 3
5 13 1817.96 34 12.42 3017 3 3
6 13 1043.96 34 13.10 1955 3 3
7 13 118.72 34 13.97 661 3 3
8 8 0.00 150 14.06 503 3 3

Cycle 161 GMT 25/ 2/2021 14:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 21 14.15 639 3 3
2 12 2003.96 54 5.70 2179 3 3
3 7 2004.76 24 10.46 3172 3 3
4 13 1927.20 34 12.21 3102 3 3
5 13 1791.40 34 12.46 2970 3 3
6 13 841.32 34 13.27 1679 3 3
7 13 90.28 34 14.02 621 3 3
8 8 0.04 150 14.05 511 3 3

Cycle 160 GMT 15/ 2/2021 15:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 22 14.15 634 3 3
2 3 969.76 -1 15.26 0 3 3
3 3 1020.76 1 11.49 1933 3 3
4 12 2005.04 54 5.75 2251 3 3
5 7 2006.40 24 10.54 3243 3 3
6 13 1929.64 34 12.23 3118 3 3
7 13 1653.16 34 12.61 2785 3 3
8 13 878.40 34 13.24 1717 3 3
9 13 47.60 34 14.08 565 3 3
10 8 0.00 150 14.07 503 3 3

Cycle 159 GMT 5/ 2/2021 16: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 22 14.16 643 3 3
2 12 2003.00 54 5.76 2365 3 3
3 7 2004.08 24 10.73 3204 3 3
4 13 1923.92 34 12.24 3113 3 3
5 13 1641.20 34 12.62 2773 3 3
6 13 708.28 34 13.38 1509 3 3
7 13 97.72 34 14.02 633 3 3
8 8 0.00 150 14.08 502 3 3

Cycle 158 GMT 26/ 1/2021 16:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 21 14.14 649 3 3
2 12 2004.00 54 5.81 2557 3 3
3 7 2005.00 24 10.91 3221 3 3
4 13 1909.72 34 12.31 3096 3 3
5 13 1638.52 34 12.65 2737 3 3
6 13 698.92 34 13.39 1490 3 3
7 13 88.88 34 14.05 612 3 3
8 8 -0.04 150 14.09 500 3 3

Cycle 157 GMT 16/ 1/2021 17:10: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 21 14.15 629 3 3
2 12 2009.04 54 6.13 2641 3 3
3 7 2009.76 24 10.98 3192 3 3
4 13 1925.92 34 12.25 3116 3 3
5 13 1784.48 34 12.48 2945 3 3
6 13 652.88 34 13.43 1418 3 3
7 8 0.08 150 14.07 494 3 3

Cycle 156 GMT 6/ 1/2021 17:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 21 14.11 652 3 3
2 12 2003.92 54 6.54 2742 3 3
3 7 2003.88 24 10.96 3194 3 3
4 13 1902.20 34 12.25 3108 3 3
5 13 1612.12 34 12.61 2728 3 3
6 13 478.76 34 13.56 1178 3 3
7 8 0.04 150 14.08 485 3 3

Cycle 155 GMT 27/12/2020 18:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 21 14.14 654 3 3
2 12 2002.60 54 7.18 2846 3 3
3 7 2001.32 24 10.99 3182 3 3
4 13 1881.16 34 12.26 3049 3 3
5 13 1276.04 34 12.87 2269 3 3
6 13 460.20 34 13.58 1150 3 3
7 8 0.00 150 14.05 502 3 3

Cycle 154 GMT 17/12/2020 19:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 21 14.14 649 3 3
2 12 2003.64 54 7.43 2866 3 3
3 7 2002.36 24 11.02 3192 3 3
4 13 1884.64 34 12.21 3065 3 3
5 13 1261.40 34 12.87 2255 3 3
6 13 289.48 34 13.74 912 3 3
7 8 0.04 150 14.05 499 3 3

Cycle 153 GMT 7/12/2020 20:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 21 14.14 638 3 3
2 12 2003.32 54 7.93 2913 3 3
3 7 2001.52 24 11.00 3212 3 3
4 13 1874.80 34 12.20 3074 3 3
5 13 1230.04 34 12.87 2209 3 3
6 13 231.88 34 13.82 819 3 3
7 8 0.12 150 14.05 500 3 3

Cycle 152 GMT 27/11/2020 21:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 21 14.14 629 3 3
2 12 2006.20 54 8.08 2922 3 3
3 7 2004.08 24 11.05 3184 3 3
4 13 1872.64 34 12.20 3070 3 3
5 13 1254.08 34 12.85 2243 3 3
6 13 243.08 34 13.80 838 3 3
7 8 0.00 150 14.05 499 3 3

Cycle 151 GMT 17/11/2020 22:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 21 14.11 633 3 3
2 12 2003.12 54 8.31 2947 3 3
3 7 2000.88 24 11.01 3217 3 3
4 13 1869.68 34 12.19 3066 3 3
5 13 1081.84 34 12.99 1995 3 3
6 13 135.56 34 13.96 674 3 3
7 8 0.04 150 14.06 498 3 3

Cycle 150 GMT 7/11/2020 23: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 21 14.12 639 3 3
2 12 2010.68 54 8.57 2989 3 3
3 7 2008.44 24 11.00 3212 3 3
4 13 1873.60 34 12.20 3073 3 3
5 13 921.32 34 13.12 1794 3 3
6 13 134.92 34 13.97 669 3 3
7 8 0.04 150 14.06 494 3 3

Cycle 149 GMT 28/10/2020 23:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 21 14.13 635 3 3
2 3 1019.64 1 11.52 1940 3 3
3 12 2003.28 54 8.99 3023 3 3
4 7 2000.60 24 11.01 3239 3 3
5 13 1854.28 34 12.22 3044 3 3
6 13 1031.32 34 13.02 1942 3 3
7 13 97.88 34 14.01 622 3 3
8 8 0.12 150 14.06 494 3 3

Cycle 148 GMT 19/10/2020 0:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 22 14.12 644 3 3
2 3 955.40 -1 15.25 0 3 3
3 12 2004.72 54 9.07 3026 3 3
4 7 2002.44 24 11.02 3181 3 3
5 13 1858.36 34 12.22 3040 3 3
6 13 1035.92 34 13.03 1934 3 3
7 13 93.56 34 14.00 619 3 3
8 8 -0.04 150 14.04 499 3 3

Cycle 147 GMT 9/10/2020 2: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 21 14.11 643 3 3
2 3 1022.56 1 11.26 1934 3 3
3 3 1018.92 1 10.93 1914 3 3
4 12 2001.88 54 9.33 3032 3 3
5 7 1998.84 24 11.03 3232 3 3
6 13 1704.04 34 12.36 2851 3 3
7 13 914.24 34 13.11 1789 3 3
8 13 110.32 34 13.98 642 3 3
9 8 0.16 150 14.04 499 3 3

Cycle 146 GMT 29/ 9/2020 3: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 21 14.12 617 3 3
2 3 964.08 -1 15.25 0 3 3
3 3 1022.84 1 11.66 1902 3 3
4 12 2003.44 54 9.42 3025 3 3
5 7 2000.64 24 11.04 3225 3 3
6 13 1580.60 34 12.50 2646 3 3
7 13 678.80 34 13.33 1449 3 3
8 13 40.80 34 14.09 542 3 3
9 8 0.00 150 14.03 495 3 3

Cycle 145 GMT 19/ 9/2020 3:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 20 14.14 615 3 3
2 3 1023.36 1 11.83 1893 3 3
3 12 2003.80 54 9.50 3040 3 3
4 7 2001.12 24 11.04 3225 3 3
5 13 1854.96 34 12.22 3015 3 3
6 13 736.24 34 13.29 1525 3 3
7 13 105.64 34 14.00 616 3 3
8 8 0.00 150 14.04 488 3 3

Cycle 144 GMT 9/ 9/2020 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 21 14.17 613 3 3
2 3 956.92 -1 15.25 0 3 3
3 12 2006.68 54 9.53 3080 3 3
4 7 2003.76 24 10.98 3227 3 3
5 13 1577.08 34 12.51 2657 3 3
6 13 788.60 34 13.24 1597 3 3
7 13 15.72 34 14.13 489 3 3
8 8 0.04 150 14.04 483 3 3

Cycle 143 GMT 30/ 8/2020 5:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 21 14.15 630 3 3
2 12 2004.60 54 9.73 3040 3 3
3 7 2001.32 24 11.08 3207 3 3
4 13 1708.00 34 12.40 2841 3 3
5 13 911.68 34 13.15 1739 3 3
6 13 47.88 34 14.09 525 3 3
7 8 0.00 150 14.05 477 3 3

Cycle 142 GMT 20/ 8/2020 6:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 22 14.14 617 3 3
2 3 964.00 -1 15.26 0 3 3
3 12 2003.32 54 9.74 3070 3 3
4 7 2000.00 24 11.06 3217 3 3
5 13 1711.60 34 12.38 2838 3 3
6 13 761.88 34 13.26 1552 3 3
7 13 25.84 34 14.12 501 3 3
8 8 0.08 150 14.06 470 3 3

Cycle 141 GMT 10/ 8/2020 7:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 22 14.16 619 3 3
2 12 2004.76 54 9.72 3057 3 3
3 7 2001.44 24 11.06 3219 3 3
4 13 1706.64 34 12.40 2831 3 3
5 13 874.40 34 13.17 1699 3 3
6 13 89.08 34 14.04 585 3 3
7 8 -0.04 150 14.06 475 3 3

Cycle 140 GMT 31/ 7/2020 8:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 21 14.15 626 3 3
2 12 2003.16 54 9.97 3056 3 3
3 7 1999.60 24 11.09 3205 3 3
4 13 1541.12 34 12.54 2612 3 3
5 13 577.64 34 13.43 1296 3 3
6 8 0.08 150 14.04 476 3 3

Cycle 139 GMT 21/ 7/2020 9:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 21 14.15 635 3 3
2 12 2000.88 54 10.01 3071 3 3
3 7 1997.36 24 11.15 3171 3 3
4 13 1545.96 34 12.56 2585 3 3
5 13 595.08 34 13.43 1309 3 3
6 8 0.08 150 14.06 472 3 3

Cycle 138 GMT 11/ 7/2020 10:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 21 14.19 606 3 3
2 12 2001.16 54 9.87 3099 3 3
3 7 1997.60 24 11.11 3206 3 3
4 13 1698.72 34 12.42 2825 3 3
5 13 725.28 34 13.31 1495 3 3
6 8 0.08 150 14.06 473 3 3

Cycle 137 GMT 1/ 7/2020 10:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 21 14.16 608 3 3
2 12 2000.60 54 10.01 3088 3 3
3 7 1997.04 24 11.09 3185 3 3
4 13 1538.12 34 12.56 2593 3 3
5 13 591.40 34 13.43 1311 3 3
6 13 28.68 34 14.13 502 3 3
7 8 0.04 150 14.06 473 3 3

Cycle 136 GMT 21/ 6/2020 11:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 21 14.19 612 3 3
2 12 2000.12 54 10.01 3087 3 3
3 7 1996.64 24 11.10 3190 3 3
4 13 1411.68 34 12.69 2420 3 3
5 13 756.68 34 13.29 1527 3 3
6 13 23.72 34 14.15 479 3 3
7 8 0.00 150 14.08 453 3 3

Cycle 135 GMT 11/ 6/2020 12:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 21 14.22 596 3 3
2 12 2001.92 54 10.08 3082 3 3
3 7 1998.56 24 11.15 3190 3 3
4 13 1539.20 34 12.58 2589 3 3
5 13 596.96 34 13.44 1313 3 3
6 13 25.36 34 14.14 491 3 3
7 8 -0.16 150 14.07 457 3 3

Cycle 134 GMT 1/ 6/2020 13:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 21 14.20 606 3 3
2 12 2003.60 54 10.03 3096 3 3
3 7 2000.16 24 11.11 3205 3 3
4 13 1537.60 34 12.57 2616 3 3
5 13 872.72 34 13.18 1684 3 3
6 13 35.68 34 14.12 510 3 3
7 8 -0.08 150 14.06 464 3 3

Cycle 133 GMT 22/ 5/2020 14:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 22 14.20 616 3 3
2 3 972.52 -1 15.26 0 3 3
3 3 1024.56 1 11.06 1904 3 3
4 12 1999.28 54 10.16 3105 3 3
5 7 1995.84 24 11.15 3168 3 3
6 13 1709.76 34 12.44 2820 3 3
7 13 866.40 34 13.20 1671 3 3
8 13 34.88 34 14.12 510 3 3
9 8 -0.08 150 14.06 469 3 3

Cycle 132 GMT 12/ 5/2020 15:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 22 14.18 613 3 3
2 3 973.52 -1 15.26 0 3 3
3 3 1020.68 1 10.20 1878 3 3
4 12 2001.84 54 10.26 3094 3 3
5 7 1998.72 24 11.19 3161 3 3
6 13 1554.92 34 12.56 2636 3 3
7 13 603.92 34 13.44 1326 3 3
8 8 0.04 150 14.09 457 3 3

Cycle 131 GMT 2/ 5/2020 16: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 21 14.22 606 3 3
2 3 1028.80 1 11.94 1917 3 3
3 12 2004.40 54 10.28 3100 3 3
4 7 2001.08 24 11.23 3171 3 3
5 13 1694.12 34 12.46 2785 3 3
6 13 562.20 34 13.49 1256 3 3
7 13 44.36 34 14.11 522 3 3
8 8 0.16 150 14.06 464 3 3

Cycle 130 GMT 22/ 4/2020 17:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 22 14.21 603 3 3
2 12 2001.16 54 10.19 3108 3 3
3 7 1997.80 24 11.17 3196 3 3
4 13 1550.80 34 12.57 2619 3 3
5 13 598.12 34 13.44 1314 3 3
6 8 0.04 150 14.10 454 3 3

Cycle 129 GMT 12/ 4/2020 18: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 21 14.21 600 3 3
2 12 2003.80 54 10.21 3108 3 3
3 7 2000.52 24 11.15 3208 3 3
4 13 1402.36 34 12.70 2404 3 3
5 13 604.00 34 13.44 1322 3 3
6 13 21.44 34 14.15 489 3 3
7 8 -0.04 150 14.07 463 3 3

Cycle 128 GMT 2/ 4/2020 18:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 21 14.19 603 3 3
2 3 1019.76 1 10.24 1900 3 3
3 12 2002.04 54 10.37 3101 3 3
4 7 1998.40 24 11.23 3150 3 3
5 13 1534.76 34 12.59 2603 3 3
6 13 441.44 34 13.60 1108 3 3
7 8 0.08 150 14.06 475 3 3

Cycle 127 GMT 23/ 3/2020 19:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 21 14.24 599 3 3
2 12 2003.48 54 10.28 3107 3 3
3 7 2000.32 24 11.18 3210 3 3
4 13 1402.56 34 12.72 2408 3 3
5 13 475.52 34 13.57 1141 3 3
6 8 0.08 150 14.06 469 3 3

Cycle 126 GMT 13/ 3/2020 20:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 21 14.20 612 3 3
2 12 2002.68 54 10.28 3115 3 3
3 7 1999.36 24 11.18 3185 3 3
4 13 1541.20 34 12.59 2594 3 3
5 13 871.40 34 13.20 1692 3 3
6 13 33.44 34 14.13 507 3 3
7 8 0.00 150 14.05 465 3 3

Cycle 125 GMT 3/ 3/2020 21:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 21 14.23 602 3 3
2 12 1999.80 54 10.28 3115 3 3
3 7 1996.20 24 11.17 3226 3 3
4 13 1537.64 34 12.61 2589 3 3
5 13 563.08 34 13.48 1269 3 3
6 13 21.04 34 14.16 492 3 3
7 8 0.00 150 14.06 465 3 3

Cycle 124 GMT 22/ 2/2020 22:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 21 14.22 601 3 3
2 3 966.24 -1 15.27 0 3 3
3 3 1026.60 1 11.01 1861 3 3
4 12 2001.56 54 10.45 3096 3 3
5 7 1998.28 24 11.22 3178 3 3
6 13 1265.84 34 12.85 2205 3 3
7 13 497.32 34 13.56 1169 3 3
8 13 28.28 34 14.16 490 3 3
9 8 -0.04 150 14.07 463 3 3

Cycle 123 GMT 12/ 2/2020 23:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 21 14.24 588 3 3
2 12 2004.40 54 10.33 3109 3 3
3 7 2001.04 24 11.20 3180 3 3
4 13 1389.76 34 12.74 2380 3 3
5 13 599.24 34 13.47 1304 3 3
6 13 22.12 34 14.18 465 3 3
7 8 0.00 150 14.09 447 3 3

Cycle 122 GMT 2/ 2/2020 23:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 21 14.23 597 3 3
2 12 2003.28 54 10.49 3081 3 3
3 7 2000.00 24 11.21 3203 3 3
4 13 1407.72 34 12.74 2399 3 3
5 13 753.44 34 13.33 1524 3 3
6 8 0.08 150 14.10 453 3 3

Cycle 121 GMT 24/ 1/2020 0:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 22 14.24 598 3 3
2 3 943.44 -1 15.28 0 3 3
3 12 2002.16 54 10.37 3118 3 3
4 7 1998.96 24 11.23 3165 3 3
5 13 1403.92 34 12.72 2418 3 3
6 13 597.60 34 13.47 1313 3 3
7 8 0.08 150 14.09 458 3 3

Cycle 120 GMT 14/ 1/2020 1:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 21 14.25 583 3 3
2 3 1036.16 1 12.32 1886 3 3
3 3 1029.52 1 12.44 1876 3 3
4 12 1998.52 54 10.51 3105 3 3
5 7 1994.80 24 11.25 3172 3 3
6 13 1684.72 34 12.49 2798 3 3
7 13 544.32 34 13.51 1240 3 3
8 13 18.56 34 14.18 477 3 3
9 8 0.00 150 14.04 464 3 3

Cycle 119 GMT 4/ 1/2020 2:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 22 14.26 577 3 3
2 3 944.24 -1 15.29 0 3 3
3 12 2004.16 54 10.39 3139 3 3
4 7 2000.56 24 11.22 3197 3 3
5 13 1556.64 34 12.61 2605 3 3
6 13 592.04 34 13.48 1289 3 3
7 8 0.04 150 14.10 442 3 3

Cycle 118 GMT 25/12/2019 3:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 21 14.24 583 3 3
2 3 1024.60 1 11.26 1851 3 3
3 12 2004.56 54 10.51 3106 3 3
4 7 2001.36 24 11.25 3172 3 3
5 13 1540.92 34 12.62 2579 3 3
6 13 707.08 34 13.39 1435 3 3
7 13 34.60 34 14.15 491 3 3
8 8 -0.04 150 14.07 449 3 3

Cycle 117 GMT 15/12/2019 4:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 22 14.23 587 3 3
2 3 966.84 -1 15.29 0 3 3
3 12 2003.28 54 10.57 3098 3 3
4 7 1999.68 24 11.20 3203 3 3
5 13 1529.76 34 12.63 2572 3 3
6 13 683.88 34 13.40 1413 3 3
7 8 0.16 150 14.10 438 3 3

Cycle 116 GMT 5/12/2019 5:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 21 14.23 579 3 3
2 12 2001.00 54 10.62 3085 3 3
3 7 1997.56 24 11.27 3199 3 3
4 13 1256.96 34 12.86 2198 3 3
5 13 469.88 34 13.60 1117 3 3
6 8 0.08 150 14.08 451 3 3

Cycle 115 GMT 25/11/2019 6:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 22 14.22 573 3 3
2 12 2000.96 54 10.57 3082 3 3
3 7 1997.32 24 11.36 3135 3 3
4 13 1540.24 34 12.63 2558 3 3
5 13 435.48 34 13.64 1074 3 3
6 8 0.08 150 14.07 453 3 3

Cycle 114 GMT 15/11/2019 7:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 21 14.24 574 3 3
2 12 1999.56 54 10.55 3094 3 3
3 7 1995.84 24 11.30 3151 3 3
4 13 1523.20 34 12.66 2528 3 3
5 13 552.04 34 13.53 1213 3 3
6 8 0.12 150 14.07 437 3 3

Cycle 113 GMT 5/11/2019 8:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 22 14.25 561 3 3
2 12 2000.64 54 10.55 3100 3 3
3 7 1997.12 24 11.33 3162 3 3
4 13 1418.32 34 12.74 2399 3 3
5 13 603.32 34 13.50 1279 3 3
6 8 0.04 150 14.09 432 3 3

Cycle 112 GMT 26/10/2019 9: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 21 14.24 586 3 3
2 3 1036.16 1 12.07 1850 3 3
3 3 1021.44 1 11.80 1853 3 3
4 12 2002.32 54 10.61 3084 3 3
5 7 1998.60 24 11.28 3181 3 3
6 13 1689.12 34 12.51 2768 3 3
7 13 525.36 34 13.57 1184 3 3
8 8 0.08 150 14.09 428 3 3

Cycle 111 GMT 16/10/2019 9:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 21 14.29 556 3 3
2 3 961.80 -1 15.30 0 3 3
3 3 1021.12 1 10.51 1817 3 3
4 12 1999.68 54 10.54 3101 3 3
5 7 1996.24 25 11.27 3179 3 3
6 13 1696.80 34 12.50 2764 3 3
7 13 526.12 34 13.57 1182 3 3
8 8 -0.04 150 14.09 434 3 3

Cycle 110 GMT 6/10/2019 10:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 21 14.25 565 3 3
2 12 2001.04 54 10.60 3072 3 3
3 7 1997.16 24 11.28 3166 3 3
4 13 1681.56 34 12.50 2742 3 3
5 13 834.28 34 13.28 1599 3 3
6 13 59.36 34 14.16 499 3 3
7 8 0.12 150 14.12 423 3 3

Cycle 109 GMT 26/ 9/2019 11:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 21 14.25 557 3 3
2 12 2001.48 54 10.64 3090 3 3
3 7 1998.12 24 11.32 3162 3 3
4 13 1552.44 34 12.64 2571 3 3
5 13 582.08 34 13.52 1245 3 3
6 8 0.04 150 14.10 420 3 3

Cycle 108 GMT 16/ 9/2019 12:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 21 14.26 563 3 3
2 12 2000.24 54 10.61 3071 3 3
3 7 1996.80 24 11.31 3150 3 3
4 13 1686.04 34 12.51 2734 3 3
5 13 536.56 34 13.57 1180 3 3
6 8 0.28 150 14.11 420 3 3

Cycle 107 GMT 6/ 9/2019 13:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 21 14.28 560 3 3
2 12 1810.44 54 10.85 2835 3 3
3 7 1807.12 24 11.46 2898 3 3
4 13 1225.60 34 12.91 2123 3 3
5 13 423.96 34 13.68 1024 3 3
6 8 0.08 150 14.10 421 3 3

Cycle 106 GMT 27/ 8/2019 13:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 20 14.25 581 3 3
2 3 1030.68 1 11.67 1881 3 3
3 3 1022.20 1 11.54 1856 3 3
4 12 2003.80 54 10.78 3066 3 3
5 7 2000.56 24 11.38 3153 3 3
6 13 1398.80 34 12.76 2364 3 3
7 13 586.04 34 13.52 1253 3 3
8 8 0.00 150 14.08 430 3 3

Cycle 105 GMT 17/ 8/2019 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 25 14.26 546 3 3
2 3 843.48 -3 15.31 0 3 3
3 3 962.52 -1 15.31 0 3 3
4 12 2002.64 54 10.79 3064 3 3
5 7 1998.88 25 11.39 3117 3 3
6 13 1380.00 34 12.79 2334 3 3
7 13 557.44 34 13.55 1219 3 3
8 8 -0.04 150 14.09 431 3 3

Cycle 104 GMT 7/ 8/2019 15:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 21 14.28 563 3 3
2 10 1027.32 3 13.10 1862 3 3
3 3 1036.92 1 12.68 1879 3 3
4 12 2002.64 54 10.74 3068 3 3
5 7 1998.96 24 11.45 3151 3 3
6 13 1529.36 34 12.67 2536 3 3
7 13 415.36 34 13.70 1009 3 3
8 8 0.12 150 14.12 418 3 3
9 14 0.12 40 14.16 416 3 3

Cycle 103 GMT 28/ 7/2019 16:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 21 14.29 574 3 3
2 12 2003.16 54 10.65 3094 3 3
3 7 1999.48 24 11.43 3129 3 3
4 13 1535.88 34 12.67 2558 3 3
5 13 561.64 34 13.54 1232 3 3
6 8 0.12 150 14.11 422 3 3

Cycle 102 GMT 18/ 7/2019 17:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 21 14.30 581 3 3
2 12 1677.48 54 11.09 2679 3 3
3 7 1673.72 24 11.63 2738 3 3
4 13 1368.84 34 12.78 2331 3 3
5 13 542.08 34 13.54 1203 3 3
6 8 0.08 150 14.08 438 3 3

Cycle 101 GMT 8/ 7/2019 17:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 21 14.31 568 3 3
2 12 1902.56 54 10.96 2954 3 3
3 7 1899.64 24 11.55 3015 3 3
4 13 1612.20 34 12.60 2651 3 3
5 13 761.24 34 13.35 1510 3 3
6 8 0.08 150 14.08 441 3 3

Cycle 100 GMT 28/ 6/2019 17:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 21 14.33 552 3 3
2 12 1999.52 54 10.84 3073 3 3
3 7 1995.40 24 11.47 3171 3 3
4 13 1688.44 34 12.55 2762 3 3
5 13 538.76 34 13.56 1197 3 3
6 8 0.04 150 14.10 426 3 3

Cycle 99 GMT 18/ 6/2019 18:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 21 14.32 582 3 3
2 12 1941.96 54 10.82 3002 3 3
3 7 1938.20 24 11.45 3099 3 3
4 13 1317.68 34 12.87 2251 3 3
5 13 520.32 34 13.59 1172 3 3
6 8 0.08 150 14.10 429 3 3

Cycle 98 GMT 8/ 6/2019 18:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 21 14.31 562 3 3
2 12 1999.44 54 10.89 3069 3 3
3 7 1995.64 24 11.50 3169 3 3
4 13 1386.16 34 12.84 2355 3 3
5 13 571.96 34 13.54 1249 3 3
6 8 0.16 150 14.11 440 3 3

Cycle 97 GMT 29/ 5/2019 19:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 21 14.34 564 3 3
2 12 2002.56 54 10.90 3056 3 3
3 7 1999.16 24 11.54 3145 3 3
4 13 1400.32 34 12.82 2368 3 3
5 13 437.56 34 13.69 1052 3 3
6 8 -0.04 150 14.13 431 3 3

Cycle 96 GMT 19/ 5/2019 20:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 21 14.32 563 3 3
2 12 2001.00 54 10.92 3070 3 3
3 7 1997.72 24 11.53 3156 3 3
4 13 1380.68 34 12.85 2322 3 3
5 13 424.44 34 13.70 1036 3 3
6 8 0.04 150 14.12 434 3 3

Cycle 95 GMT 9/ 5/2019 21:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 21 14.33 572 3 3
2 3 971.28 -1 15.32 0 3 3
3 12 2001.00 54 10.97 3073 3 3
4 7 1997.32 24 11.57 3156 3 3
5 13 1532.12 34 12.73 2534 3 3
6 13 536.48 34 13.58 1200 3 3
7 8 0.08 150 14.10 437 3 3

Cycle 94 GMT 29/ 4/2019 22:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 20 14.34 573 3 3
2 3 1033.64 1 12.17 1870 3 3
3 3 1021.68 1 12.15 1866 3 3
4 12 2000.04 54 10.88 3062 3 3
5 7 1996.36 24 11.63 3111 3 3
6 13 1691.44 34 12.62 2748 3 3
7 13 525.44 34 13.60 1175 3 3
8 8 0.12 150 14.13 434 3 3

Cycle 93 GMT 19/ 4/2019 23:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 20 14.33 581 3 3
2 12 2004.20 51 10.85 3072 3 3
3 7 2000.96 24 11.60 3149 3 3
4 13 1550.92 34 12.72 2580 3 3
5 13 576.96 34 13.55 1257 3 3
6 8 0.04 150 14.11 441 3 3

Cycle 92 GMT 10/ 4/2019 0:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 20 14.36 550 3 3
2 3 1023.52 1 11.60 1856 3 3
3 12 2001.88 51 10.87 3047 3 3
4 7 1998.44 24 11.61 3140 3 3
5 13 1698.92 34 12.64 2745 3 3
6 13 659.24 34 13.49 1348 3 3
7 13 26.64 34 14.23 456 3 3
8 8 0.08 150 14.08 432 3 3

Cycle 91 GMT 31/ 3/2019 1:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 20 14.33 566 3 3
2 3 969.60 -1 15.32 0 3 3
3 12 2003.52 51 10.85 3038 3 3
4 7 1999.84 24 11.57 3168 3 3
5 13 1552.80 32 12.80 2553 3 3
6 13 578.12 32 13.58 1240 3 3
7 13 48.36 32 14.20 476 3 3
8 8 -0.04 150 14.11 404 3 3

Cycle 90 GMT 21/ 3/2019 2:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 21 14.35 559 3 3
2 12 2002.24 51 10.84 3027 3 3
3 7 1998.40 24 11.58 3133 3 3
4 13 1533.40 32 12.82 2528 3 3
5 13 701.44 32 13.50 1390 3 3
6 13 34.16 32 14.21 477 3 3
7 8 0.04 150 14.08 429 3 3

Cycle 89 GMT 11/ 3/2019 3:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 21 14.38 564 3 3
2 12 2004.52 51 10.78 3044 3 3
3 7 2001.08 24 11.57 3153 3 3
4 13 1536.04 32 12.83 2554 3 3
5 13 557.16 32 13.61 1220 3 3
6 13 25.60 32 14.24 460 3 3
7 8 0.00 150 14.09 430 3 3

Cycle 88 GMT 1/ 3/2019 4:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 21 14.37 558 3 3
2 12 2009.32 45 10.80 3019 3 3
3 7 2006.60 24 11.63 3138 3 3
4 13 1715.00 25 12.85 2780 3 3
5 13 934.36 25 13.41 1717 3 3
6 13 173.12 25 14.06 662 3 3
7 8 0.04 150 14.14 427 3 3

Cycle 87 GMT 19/ 2/2019 4:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 21 14.40 559 3 3
2 12 2002.16 45 10.77 3008 3 3
3 7 1999.04 24 11.58 3149 3 3
4 13 1714.80 25 12.87 2765 3 3
5 13 1068.80 25 13.33 1888 3 3
6 13 263.68 25 13.97 798 3 3
7 8 0.08 150 14.15 417 3 3

Cycle 86 GMT 9/ 2/2019 5:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 20 14.37 558 3 3
2 3 1028.64 1 12.03 1844 3 3
3 3 1021.48 1 11.94 1848 3 3
4 12 2003.96 41 10.70 2997 3 3
5 7 2001.20 24 11.64 3104 3 3
6 13 1569.60 25 12.97 2586 3 3
7 13 956.88 25 13.41 1728 3 3
8 13 203.20 25 14.05 687 3 3
9 8 0.04 150 14.16 415 3 3

Cycle 85 GMT 30/ 1/2019 6:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 21 14.38 544 3 3
2 12 2003.56 41 10.66 2974 3 3
3 7 2000.64 24 11.66 3117 3 3
4 13 1702.52 25 12.89 2740 3 3
5 13 1079.96 25 13.31 1904 3 3
6 13 317.96 25 13.92 870 3 3
7 8 0.04 150 14.15 411 3 3

Cycle 84 GMT 20/ 1/2019 6:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 21 14.38 547 3 3
2 12 2003.20 36 10.61 2971 3 3
3 7 2000.72 24 11.65 3160 3 3
4 13 1859.04 25 12.74 2949 3 3
5 13 1227.56 25 13.22 2129 3 3
6 13 439.28 25 13.81 1051 3 3
7 13 29.12 25 14.28 448 3 3
8 8 0.04 150 14.14 403 3 3

Cycle 83 GMT 10/ 1/2019 7:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 21 14.41 553 3 3
2 3 959.24 -1 15.34 0 3 3
3 3 1020.96 1 11.19 1859 3 3
4 12 2005.96 36 10.61 2991 3 3
5 7 2003.68 24 11.65 3132 3 3
6 13 1715.60 25 12.89 2780 3 3
7 13 1103.72 25 13.34 1923 3 3
8 13 321.44 25 13.92 875 3 3
9 13 16.76 25 14.31 424 3 3
10 8 0.04 150 14.11 416 3 3

Cycle 82 GMT 31/12/2018 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 21 14.38 555 3 3
2 12 2005.76 36 10.59 2978 3 3
3 7 2003.52 24 11.71 3138 3 3
4 13 1867.40 25 12.74 2986 3 3
5 13 1101.56 25 13.33 1948 3 3
6 13 481.60 25 13.79 1090 3 3
7 13 34.32 25 14.30 448 3 3
8 8 -0.08 150 14.13 409 3 3

Cycle 81 GMT 21/12/2018 8:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 20 14.43 539 3 3
2 3 1024.04 1 11.95 1844 3 3
3 12 2000.32 36 10.76 2996 3 3
4 7 1997.80 24 11.73 3112 3 3
5 13 1714.24 25 12.88 2773 3 3
6 13 1254.48 25 13.24 2148 3 3
7 13 445.88 25 13.83 1041 3 3
8 8 0.04 150 14.16 404 3 3

Cycle 80 GMT 11/12/2018 9:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 20 14.42 537 3 3
2 12 2000.32 36 10.72 2990 3 3
3 7 1997.36 24 11.66 3136 3 3
4 13 1716.20 25 12.89 2755 3 3
5 13 1108.08 25 13.34 1947 3 3
6 13 340.56 25 13.93 894 3 3
7 8 0.08 150 14.19 395 3 3

Cycle 79 GMT 1/12/2018 10: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 20 14.42 553 3 3
2 7 2002.96 44 10.62 3061 3 3
3 13 1883.00 42 12.33 2981 3 3
4 13 956.88 42 13.22 1730 3 3
5 13 23.92 42 14.31 424 3 3
6 8 0.00 150 14.17 399 3 3

Cycle 78 GMT 21/11/2018 11: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 20 14.45 520 3 3
2 7 2003.20 44 10.62 3053 3 3
3 13 1886.88 42 12.35 2969 3 3
4 13 837.96 42 13.34 1588 3 3
5 13 16.36 42 14.33 421 3 3
6 8 0.08 150 14.13 409 3 3

Cycle 77 GMT 11/11/2018 11:41: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 21 14.44 541 3 3
2 7 2007.64 44 10.63 3081 3 3
3 13 1892.36 42 12.35 2978 3 3
4 13 1001.96 42 13.22 1761 3 3
5 13 15.52 42 14.34 405 3 3
6 8 -0.08 150 14.14 383 3 3

Cycle 76 GMT 1/11/2018 12:14: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 21 14.44 528 3 3
2 7 2003.40 44 10.68 3076 3 3
3 13 1875.72 42 12.38 2959 3 3
4 13 837.76 42 13.36 1566 3 3
5 8 0.04 150 14.21 384 3 3

Cycle 75 GMT 22/10/2018 12:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 20 14.45 528 3 3
2 7 1696.44 44 11.11 2692 3 3
3 13 1588.12 42 12.60 2578 3 3
4 13 690.76 42 13.49 1368 3 3
5 8 0.08 150 14.21 385 3 3

Cycle 74 GMT 12/10/2018 12:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 20 14.45 525 3 3
2 7 1822.36 44 11.05 2851 3 3
3 13 1703.96 42 12.52 2716 3 3
4 13 672.40 42 13.52 1342 3 3
5 8 0.08 150 14.20 385 3 3

Cycle 73 GMT 2/10/2018 12:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 21 14.45 532 3 3
2 3 946.72 -1 15.33 0 3 3
3 7 2006.00 44 11.04 3096 3 3
4 13 1894.12 42 12.41 2961 3 3
5 13 961.20 42 13.29 1711 3 3
6 8 0.00 150 14.22 379 3 3
7 14 0.00 40 14.22 381 3 3

Cycle 72 GMT 22/ 9/2018 13:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 20 14.46 522 3 3
2 12 2002.24 36 11.23 3014 3 3
3 7 1999.32 24 11.83 3100 3 3
4 13 1452.44 35 12.95 2378 3 3
5 13 333.72 35 13.93 865 3 3
6 8 -0.04 150 14.20 380 3 3

Cycle 71 GMT 12/ 9/2018 13:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 21 14.48 519 3 3
2 12 2006.44 36 11.30 3014 3 3
3 7 2003.88 24 11.88 3105 3 3
4 13 1602.76 35 12.86 2584 3 3
5 13 426.24 35 13.84 989 3 3
6 8 0.12 150 14.20 377 3 3

Cycle 70 GMT 2/ 9/2018 14: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 20 14.49 524 3 3
2 3 1026.24 1 12.81 1836 3 3
3 12 2003.96 36 11.35 3014 3 3
4 7 2001.56 24 11.95 3085 3 3
5 13 1355.28 35 13.06 2263 3 3
6 13 366.04 35 13.90 923 3 3
7 8 0.16 150 14.21 378 3 3

Cycle 69 GMT 23/ 8/2018 14:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 20 14.45 526 3 3
2 12 2006.72 36 11.36 3015 3 3
3 7 2004.20 24 11.93 3118 3 3
4 13 1342.40 35 13.06 2264 3 3
5 13 473.32 35 13.80 1060 3 3
6 8 0.04 150 14.20 376 3 3

Cycle 68 GMT 13/ 8/2018 14:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 20 14.50 489 3 3
2 12 2000.80 36 11.40 3027 3 3
3 7 1997.72 24 11.99 3087 3 3
4 13 1343.92 35 13.09 2229 3 3
5 13 462.12 35 13.82 1033 3 3
6 8 0.68 150 14.21 372 3 3

Cycle 67 GMT 3/ 8/2018 14:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 21 14.48 529 3 3
2 3 956.60 -1 15.32 0 3 3
3 12 2004.20 36 11.37 3036 3 3
4 7 2001.64 24 11.99 3102 3 3
5 13 1450.72 35 13.03 2370 3 3
6 13 308.24 35 13.98 815 3 3
7 8 0.04 150 14.22 365 3 3

Cycle 66 GMT 24/ 7/2018 15:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 21 14.52 508 3 3
2 12 2001.24 36 11.45 3042 3 3
3 7 1998.44 24 12.04 3101 3 3
4 13 1328.04 35 13.13 2205 3 3
5 13 331.92 35 13.96 855 3 3
6 8 0.08 150 14.21 374 3 3

Cycle 65 GMT 14/ 7/2018 15:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 21 14.50 514 3 3
2 7 2004.28 46 11.68 3082 3 3
3 13 1756.04 37 12.77 2756 3 3
4 13 732.60 37 13.57 1413 3 3
5 8 0.12 150 14.23 373 3 3

Cycle 64 GMT 4/ 7/2018 15:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 20 14.49 535 3 3
2 7 2001.48 45 11.83 3089 3 3
3 13 1745.80 37 12.78 2756 3 3
4 13 764.44 37 13.56 1451 3 3
5 8 -0.08 150 14.24 364 3 3

Cycle 63 GMT 24/ 6/2018 16:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 21 14.52 491 3 3
2 3 957.52 -1 15.31 0 3 3
3 7 2004.20 45 11.82 3079 3 3
4 13 1615.80 37 12.91 2581 3 3
5 13 616.72 37 13.69 1241 3 3
6 8 0.04 150 14.23 374 3 3

Cycle 62 GMT 14/ 6/2018 16:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 20 14.55 499 3 3
2 3 1048.48 1 13.74 1857 3 3
3 7 2004.60 45 11.95 3083 3 3
4 13 1635.16 37 12.91 2607 3 3
5 13 771.72 37 13.55 1466 3 3
6 8 0.08 150 14.25 357 3 3

Cycle 61 GMT 4/ 6/2018 16:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 20 14.52 517 3 3
2 7 2005.08 45 11.94 3082 3 3
3 13 1628.68 37 12.92 2598 3 3
4 13 650.28 37 13.67 1296 3 3
5 8 0.20 150 14.24 371 3 3

Cycle 60 GMT 25/ 5/2018 17:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 20 14.52 523 3 3
2 7 2001.64 42 12.06 3093 3 3
3 13 1745.36 37 12.84 2783 3 3
4 13 870.12 37 13.50 1595 3 3
5 13 45.96 37 14.31 443 3 3
6 8 0.04 150 14.19 380 3 3

Cycle 59 GMT 15/ 5/2018 17:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 20 14.54 497 3 3
2 7 2002.76 42 12.15 3064 3 3
3 13 1883.92 37 12.71 2921 3 3
4 13 961.40 37 13.45 1676 3 3
5 13 40.44 37 14.35 410 3 3
6 8 0.08 150 14.20 368 3 3

Cycle 58 GMT 5/ 5/2018 18:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 20 14.53 505 3 3
2 7 2007.96 42 12.26 3081 3 3
3 13 1885.44 37 12.74 2910 3 3
4 13 979.48 37 13.44 1707 3 3
5 13 34.68 37 14.36 399 3 3
6 8 0.00 150 14.21 356 3 3

Cycle 57 GMT 25/ 4/2018 19: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 20 14.55 493 3 3
2 7 2003.92 51 12.27 3070 3 3
3 13 1600.00 34 13.07 2536 3 3
4 13 685.68 34 13.69 1333 3 3
5 13 35.92 34 14.35 403 3 3
6 8 0.04 150 14.20 357 3 3

Cycle 56 GMT 15/ 4/2018 19:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 20 14.55 497 3 3
2 7 2005.04 51 12.38 3078 3 3
3 13 1605.08 34 13.07 2566 3 3
4 13 684.36 34 13.70 1330 3 3
5 8 0.04 150 14.25 353 3 3

Cycle 55 GMT 5/ 4/2018 20:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 20 14.55 478 3 3
2 7 2003.32 51 12.43 3080 3 3
3 13 1469.60 34 13.17 2394 3 3
4 13 696.04 34 13.69 1346 3 3
5 8 0.12 150 14.26 354 3 3

Cycle 54 GMT 26/ 3/2018 21: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 20 14.56 502 3 3
2 7 2002.44 51 12.49 3072 3 3
3 13 1444.72 34 13.18 2353 3 3
4 13 558.88 34 13.81 1155 3 3
5 8 0.16 150 14.27 344 3 3

Cycle 53 GMT 16/ 3/2018 21:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 20 14.56 483 3 3
2 3 962.24 -1 15.28 0 3 3
3 7 2004.80 51 12.54 3076 3 3
4 13 1726.76 34 13.04 2713 3 3
5 13 649.76 34 13.74 1276 3 3
6 13 28.76 34 14.36 401 3 3
7 8 0.04 150 14.21 361 3 3

Cycle 52 GMT 6/ 3/2018 22:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 20 14.56 488 3 3
2 7 2003.56 51 12.59 3076 3 3
3 13 1590.52 34 13.13 2525 3 3
4 13 663.96 34 13.73 1294 3 3
5 13 32.64 34 14.36 394 3 3
6 8 0.00 150 14.21 352 3 3

Cycle 51 GMT 24/ 2/2018 22:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 20 14.56 481 3 3
2 7 2003.52 51 12.64 3071 3 3
3 13 1603.12 34 13.14 2553 3 3
4 13 562.32 34 13.81 1156 3 3
5 8 0.12 150 14.26 351 3 3

Cycle 50 GMT 14/ 2/2018 23:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 20 14.57 475 3 3
2 7 2004.04 51 12.68 3073 3 3
3 13 1590.64 34 13.16 2530 3 3
4 13 551.12 34 13.82 1139 3 3
5 8 0.12 150 14.28 345 3 3

Cycle 49 GMT 4/ 2/2018 23:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 20 14.57 483 3 3
2 7 2004.56 51 12.70 3073 3 3
3 13 1578.40 34 13.16 2525 3 3
4 13 508.80 34 13.87 1071 3 3
5 8 0.12 150 14.27 340 3 3

Cycle 48 GMT 26/ 1/2018 0:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 20 14.58 476 3 3
2 7 2003.20 49 12.79 3071 3 3
3 13 1585.64 34 13.17 2538 3 3
4 13 675.40 34 13.74 1308 3 3
5 8 0.04 150 14.26 345 3 3

Cycle 47 GMT 16/ 1/2018 1: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 20 14.59 477 3 3
2 7 2005.00 49 12.80 3077 3 3
3 13 1731.32 34 13.10 2728 3 3
4 13 769.56 34 13.68 1426 3 3
5 13 26.40 34 14.41 372 3 3
6 8 -0.04 150 14.26 339 3 3

Cycle 46 GMT 6/ 1/2018 1:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 20 14.59 482 3 3
2 7 2002.88 48 12.82 3081 3 3
3 13 1462.44 34 13.26 2350 3 3
4 13 704.44 34 13.74 1348 3 3
5 8 0.12 150 14.31 337 3 3

Cycle 45 GMT 27/12/2017 2:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 20 14.60 481 3 3
2 7 2002.56 48 12.86 3053 3 3
3 13 1730.64 34 13.13 2733 3 3
4 13 638.52 34 13.79 1274 3 3
5 8 0.20 150 14.31 351 3 3

Cycle 44 GMT 17/12/2017 2:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 20 14.62 479 3 3
2 7 2003.84 48 12.86 3073 3 3
3 13 1453.68 34 13.28 2350 3 3
4 13 557.16 34 13.88 1136 3 3
5 8 0.20 150 14.30 340 3 3

Cycle 43 GMT 7/12/2017 3:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 21 14.62 474 3 3
2 3 970.00 -1 15.31 0 3 3
3 7 2002.84 48 12.87 3077 3 3
4 13 1594.44 34 13.23 2539 3 3
5 13 549.12 34 13.89 1135 3 3
6 8 0.08 150 14.33 343 3 3

Cycle 42 GMT 27/11/2017 3:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 20 14.62 495 3 3
2 3 1024.96 1 14.24 1791 3 3
3 7 2004.88 49 12.89 3067 3 3
4 13 1605.72 34 13.23 2569 3 3
5 13 556.40 34 13.90 1141 3 3
6 8 0.04 150 14.32 348 3 3

Cycle 41 GMT 17/11/2017 4: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 20 14.64 466 3 3
2 7 2001.44 48 12.91 3067 3 3
3 13 1589.20 34 13.25 2535 3 3
4 13 688.28 34 13.81 1322 3 3
5 8 0.08 150 14.31 342 3 3

Cycle 40 GMT 7/11/2017 4:26:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 19 14.64 476 3 3
2 3 1035.52 1 14.30 1815 3 3
3 7 2005.04 48 12.93 3062 3 3
4 13 1471.92 34 13.32 2365 3 3
5 13 716.48 34 13.80 1350 3 3
6 8 0.08 150 14.37 326 3 3

Cycle 39 GMT 28/10/2017 4:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 20 14.63 474 3 3
2 3 968.08 -1 15.34 0 3 3
3 3 1018.92 1 13.88 1818 3 3
4 7 2003.04 48 12.93 3059 3 3
5 13 1582.48 34 13.27 2519 3 3
6 13 808.28 34 13.73 1501 3 3
7 8 0.12 150 14.34 341 3 3

Cycle 38 GMT 18/10/2017 5:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 20 14.63 458 3 3
2 7 2005.20 48 12.94 3054 3 3
3 13 1603.32 34 13.26 2540 3 3
4 13 673.28 34 13.85 1293 3 3
5 13 35.28 34 14.49 387 3 3
6 8 -0.08 150 14.32 334 3 3

Cycle 37 GMT 8/10/2017 6: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 21 14.65 466 3 3
2 7 2004.28 48 12.96 3053 3 3
3 13 1600.84 34 13.26 2509 3 3
4 13 693.24 34 13.84 1321 3 3
5 8 0.12 150 14.36 331 3 3

Cycle 36 GMT 28/ 9/2017 6:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 19 14.65 460 3 3
2 3 1041.84 1 14.39 1821 3 3
3 7 2003.32 48 12.95 3063 3 3
4 13 1447.96 34 13.35 2349 3 3
5 13 540.16 34 13.97 1103 3 3
6 8 0.04 150 14.37 324 3 3

Cycle 35 GMT 18/ 9/2017 6:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 20 14.65 472 3 3
2 7 2002.32 48 12.95 3066 3 3
3 13 1576.44 34 13.28 2498 3 3
4 13 651.20 34 13.87 1277 3 3
5 8 0.00 150 14.36 333 3 3

Cycle 34 GMT 8/ 9/2017 7:11: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 19 14.67 451 3 3
2 7 2002.28 48 12.97 3058 3 3
3 13 1738.96 34 13.20 2721 3 3
4 13 654.68 34 13.88 1272 3 3
5 13 29.76 34 14.52 366 3 3
6 8 0.00 150 14.33 326 3 3

Cycle 33 GMT 29/ 8/2017 7:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 21 14.64 441 3 3
2 3 952.52 -1 15.39 0 3 3
3 7 2005.76 48 12.97 3055 3 3
4 13 1600.56 34 13.27 2541 3 3
5 13 548.88 34 13.97 1126 3 3
6 13 46.68 34 14.51 392 3 3
7 8 0.04 150 14.34 321 3 3

Cycle 32 GMT 19/ 8/2017 8:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 20 14.66 441 3 3
2 3 1029.88 1 14.40 1798 3 3
3 7 2008.00 48 12.97 3057 3 3
4 13 1603.64 34 13.28 2535 3 3
5 13 549.00 34 13.98 1122 3 3
6 8 0.12 150 14.40 313 3 3

Cycle 31 GMT 9/ 8/2017 8:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 20 14.65 452 3 3
2 7 2005.64 48 12.98 3050 3 3
3 13 1464.56 34 13.35 2354 3 3
4 13 565.24 34 13.97 1131 3 3
5 8 0.08 150 14.40 310 3 3

Cycle 30 GMT 30/ 7/2017 8:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 20 14.67 436 3 3
2 3 965.24 -1 15.41 0 3 3
3 7 2005.88 49 12.98 3041 3 3
4 13 1738.08 34 13.21 2699 3 3
5 13 775.72 34 13.81 1414 3 3
6 8 0.12 150 14.41 303 3 3

Cycle 29 GMT 20/ 7/2017 9:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 21 14.67 436 3 3
2 3 971.68 -1 15.41 0 3 3
3 7 2001.68 48 12.98 3042 3 3
4 13 1466.80 34 13.35 2328 3 3
5 13 555.52 34 13.98 1113 3 3
6 13 43.56 34 14.53 366 3 3
7 8 0.00 150 14.36 303 3 3

Cycle 28 GMT 10/ 7/2017 9:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 22 14.67 439 3 3
2 7 2005.00 48 12.97 3036 3 3
3 13 1570.64 34 13.29 2478 3 3
4 13 645.92 34 13.91 1243 3 3
5 8 0.12 150 14.40 305 3 3

Cycle 27 GMT 30/ 6/2017 10: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 21 14.71 441 3 3
2 3 1055.68 1 14.52 1811 3 3
3 7 2003.16 48 12.97 3043 3 3
4 13 1455.60 34 13.35 2319 3 3
5 13 700.72 34 13.86 1319 3 3
6 8 0.12 150 14.38 306 3 3

Cycle 26 GMT 20/ 6/2017 10:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 20 14.69 432 3 3
2 3 1023.32 1 14.42 1805 3 3
3 7 2002.84 49 12.96 3038 3 3
4 13 1579.52 34 13.30 2480 3 3
5 13 508.24 34 14.02 1048 3 3
6 13 38.76 34 14.54 361 3 3
7 8 0.00 150 14.35 304 3 3

Cycle 25 GMT 10/ 6/2017 11: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 20 14.69 425 3 3
2 3 973.40 -1 15.44 0 3 3
3 3 1027.64 1 14.42 1788 3 3
4 7 2002.68 49 12.97 3032 3 3
5 13 1583.00 34 13.28 2494 3 3
6 13 511.52 34 14.03 1048 3 3
7 8 0.08 150 14.40 302 3 3

Cycle 24 GMT 31/ 5/2017 11:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 20 14.67 423 3 3
2 7 2001.40 48 12.97 3028 3 3
3 13 1468.08 34 13.35 2313 3 3
4 13 688.44 34 13.87 1296 3 3
5 8 -0.08 150 14.40 298 3 3

Cycle 23 GMT 21/ 5/2017 12:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 20 14.72 418 3 3
2 7 2001.88 48 12.93 3024 3 3
3 13 1591.08 34 13.25 2499 3 3
4 13 546.64 34 13.99 1098 3 3
5 8 0.12 150 14.40 297 3 3

Cycle 22 GMT 11/ 5/2017 12:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 24 14.69 422 3 3
2 3 857.40 -3 15.45 0 3 3
3 7 2002.44 46 12.97 3017 3 3
4 13 1578.88 34 13.27 2474 3 3
5 13 671.56 34 13.88 1266 3 3
6 8 0.12 150 14.42 291 3 3

Cycle 21 GMT 1/ 5/2017 13: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 20 14.75 411 3 3
2 10 1018.88 3 14.53 1747 3 3
3 3 1041.68 1 14.47 1812 3 3
4 7 2003.52 45 12.98 3017 3 3
5 13 1732.92 34 13.18 2665 3 3
6 13 654.88 34 13.89 1246 3 3
7 13 36.00 34 14.57 346 3 3
8 8 -0.04 150 14.38 293 3 3

Cycle 20 GMT 21/ 4/2017 13:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 19 14.72 420 3 3
2 3 1051.08 1 14.50 1805 3 3
3 7 2003.60 45 12.95 3025 3 3
4 13 1594.36 25 13.35 2513 3 3
5 13 756.48 25 13.90 1389 3 3
6 13 184.12 25 14.40 574 3 3
7 8 0.16 150 14.42 288 3 3

Cycle 19 GMT 11/ 4/2017 13:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 20 14.74 412 3 3
2 3 960.24 -1 15.46 0 3 3
3 7 2003.32 46 12.93 3038 3 3
4 13 1587.84 25 13.36 2477 3 3
5 13 879.00 25 13.80 1545 3 3
6 13 160.44 25 14.42 538 3 3
7 8 0.04 150 14.42 291 3 3

Cycle 18 GMT 1/ 4/2017 13:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 20 14.73 412 3 3
2 7 2005.08 45 12.91 3034 3 3
3 13 1606.52 25 13.32 2517 3 3
4 13 902.04 25 13.78 1563 3 3
5 13 166.12 25 14.42 542 3 3
6 8 0.08 150 14.42 286 3 3

Cycle 17 GMT 22/ 3/2017 13:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 19 14.74 417 3 3
2 3 1059.56 2 14.51 1821 3 3
3 7 2001.88 45 12.89 3030 3 3
4 13 1604.28 25 13.32 2512 3 3
5 13 894.08 25 13.78 1553 3 3
6 13 178.96 25 14.40 563 3 3
7 8 0.12 150 14.42 286 3 3

Cycle 16 GMT 12/ 3/2017 13:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 24 14.69 410 3 3
2 3 787.84 -4 15.47 0 3 3
3 3 955.16 -1 15.46 0 3 3
4 7 2002.24 42 12.93 3016 3 3
5 13 1604.16 22 13.34 2489 3 3
6 13 941.76 22 13.76 1611 3 3
7 13 381.72 22 14.19 850 3 3
8 13 22.80 22 14.64 318 3 3
9 8 0.12 150 14.39 281 3 3

Cycle 15 GMT 2/ 3/2017 13:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 23 14.75 414 3 3
2 3 1044.56 1 14.45 1775 3 3
3 7 2003.60 43 12.87 3014 3 3
4 13 1501.44 22 13.36 2357 3 3
5 13 967.36 22 13.74 1627 3 3
6 13 292.40 22 14.27 720 3 3
7 13 30.88 22 14.62 325 3 3
8 8 0.08 150 14.39 277 3 3

Cycle 14 GMT 20/ 2/2017 13: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 23 14.71 398 3 3
2 3 1025.28 1 14.40 1758 3 3
3 7 1516.68 42 13.30 2318 3 3
4 13 1409.68 22 13.43 2241 3 3
5 13 769.84 22 13.83 1370 3 3
6 13 731.60 22 13.86 1329 3 3
7 13 681.96 22 13.91 1266 3 3
8 13 632.68 22 13.97 1192 3 3
9 13 568.16 22 14.04 1104 3 3
10 13 498.84 22 14.10 1009 3 3
11 13 407.20 22 14.19 875 3 3
12 8 -0.08 190 14.35 282 3 4

Cycle 13 GMT 19/ 2/2017 12:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 26 14.69 396 3 3
2 3 888.60 -2 15.46 0 3 3
3 7 1507.48 43 13.20 2303 3 3
4 13 1403.60 22 13.37 2229 3 3
5 13 864.32 22 13.73 1488 3 3
6 13 168.24 22 14.38 531 3 3
7 8 0.04 190 14.37 270 3 3

Cycle 12 GMT 18/ 2/2017 12:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1073.28 8 13.93 1777 3 3
2 10 1142.80 7 13.76 1869 3 3
3 10 1202.32 6 13.69 1953 3 3
4 10 1232.44 3 13.77 1990 3 3
5 3 1211.20 5 13.84 2003 3 3
6 3 1056.84 1 14.05 1786 3 3
7 7 1514.84 74 12.69 2301 3 3
8 13 672.12 25 13.77 1239 3 3
9 13 104.60 25 14.41 431 3 3
10 8 0.04 240 14.29 269 3 3

Cycle 11 GMT 17/ 2/2017 13:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.51 0 3 3
2 3 -0.04 -19 15.51 0 3 3
3 7 -0.04 74 14.86 214 3 4
4 8 -0.04 240 14.71 209 3 10

Cycle 10 GMT 16/ 2/2017 16:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.51 0 3 3
2 3 0.00 -19 15.51 0 3 3
3 7 0.00 74 14.84 212 3 4
4 8 0.00 240 14.70 207 3 10

Cycle 9 GMT 15/ 2/2017 19:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.50 0 3 3
2 3 0.00 -19 15.50 0 3 3
3 7 0.00 74 14.90 208 3 4
4 8 0.00 240 14.69 206 3 10

Cycle 8 GMT 15/ 2/2017 9:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.51 0 3 3
2 3 -0.04 -19 15.52 0 3 3
3 7 0.00 74 14.32 198 3 3
4 8 0.00 240 14.54 203 3 8

Cycle 7 GMT 5/ 2/2017 12:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.52 0 3 3
2 3 -0.04 -19 15.53 0 3 3
3 7 -0.04 74 14.37 202 3 3
4 8 -0.04 240 14.59 201 3 3

Cycle 6 GMT 26/ 1/2017 15: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.52 0 3 3
2 3 -0.04 -19 15.52 0 3 3
3 7 0.04 74 14.43 200 3 3
4 8 0.04 240 14.61 201 3 3

Cycle 5 GMT 16/ 1/2017 17:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.52 0 3 3
2 3 0.00 -19 15.53 0 3 3
3 7 0.00 74 14.42 209 3 3
4 8 0.00 240 14.58 208 3 3

Cycle 4 GMT 6/ 1/2017 20:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.52 0 3 3
2 3 0.00 -19 15.52 0 3 3
3 7 0.00 74 14.92 203 3 3
4 8 0.00 240 14.78 201 3 3

Cycle 3 GMT 5/ 1/2017 23:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.51 0 3 3
2 3 -0.04 -19 15.52 0 3 3
3 7 -0.04 74 14.93 201 3 3
4 8 -0.04 240 14.79 198 3 3

Cycle 2 GMT 5/ 1/2017 2: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.51 0 3 3
2 3 -0.04 -19 15.51 0 3 3
3 7 0.00 74 14.91 202 3 3
4 8 -0.04 240 14.77 199 3 3

Cycle 1 GMT 4/ 1/2017 5:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.52 0 3 3
2 3 0.00 -19 15.51 0 3 3
3 7 0.00 74 14.92 203 3 3
4 8 0.00 240 14.73 199 3 3

Cycle 0 GMT 3/ 1/2017 18:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.08 24 14.35 195 3 3
2 7 0.08 74 14.48 195 3 3
3 8 0.08 240 14.63 193 3 3