SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8817 WMO= 3902171


Cycle 188 GMT 13/12/2024 2:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 30 14.77 441 2 3
2 7 2003.56 53 14.74 3069 2 2
3 13 987.84 20 14.69 1703 2 3
4 13 246.40 20 14.81 648 2 3
5 8 0.12 165 14.83 264 2 8

Cycle 187 GMT 3/12/2024 7:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 30 14.76 439 2 3
2 7 2004.28 53 14.74 3065 2 2
3 13 1001.92 20 14.68 1719 2 3
4 13 247.16 20 14.80 654 2 3
5 8 0.04 165 14.82 264 2 4

Cycle 186 GMT 23/11/2024 13:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 30 14.77 442 2 3
2 7 2009.24 53 14.74 3071 2 2
3 13 995.36 20 14.66 1705 2 4
4 13 257.16 20 14.82 661 2 3
5 8 0.24 165 14.82 262 2 6

Cycle 185 GMT 13/11/2024 18:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 30 14.77 449 2 3
2 7 2005.80 53 14.72 3070 2 2
3 13 996.76 20 14.67 1710 2 3
4 13 241.44 20 14.81 639 2 3
5 8 0.12 165 14.83 262 2 3

Cycle 184 GMT 3/11/2024 23:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 30 14.78 439 2 3
2 7 2011.56 52 14.73 3081 2 2
3 13 999.32 20 14.68 1720 2 3
4 13 249.72 20 14.81 653 2 3
5 8 -0.04 165 14.83 263 2 3

Cycle 183 GMT 25/10/2024 4:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 14.77 417 2 3
2 7 2012.00 52 14.73 3072 2 2
3 13 1006.00 20 14.68 1731 2 4
4 13 245.96 20 14.82 646 2 4
5 8 0.16 165 14.84 264 2 5

Cycle 182 GMT 15/10/2024 9:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 30 14.77 439 2 3
2 7 2008.08 52 14.74 3070 2 2
3 13 994.60 20 14.69 1707 2 4
4 13 254.92 20 14.82 662 2 3
5 8 0.24 165 14.85 263 2 8
6 14 0.24 30 14.82 264 3 6

Cycle 181 GMT 5/10/2024 15: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 30 14.78 441 2 3
2 7 2004.16 52 14.74 3070 2 2
3 13 1003.80 20 14.68 1720 2 3
4 13 257.40 20 14.81 661 2 3
5 8 0.08 165 14.84 263 2 5
6 14 0.08 30 14.82 264 2 5

Cycle 180 GMT 25/ 9/2024 20:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 14.78 432 2 3
2 7 2004.68 53 14.75 3073 2 2
3 13 995.52 20 14.66 1711 2 3
4 13 250.72 20 14.82 655 2 3
5 8 0.00 165 14.83 264 2 7

Cycle 179 GMT 16/ 9/2024 1:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 30 14.78 438 2 3
2 7 2010.04 53 14.73 3083 2 2
3 13 993.08 20 14.68 1700 2 4
4 13 258.52 20 14.83 665 2 3
5 8 0.00 165 14.84 261 2 6

Cycle 178 GMT 6/ 9/2024 6:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 30 14.79 438 2 3
2 7 2003.64 53 14.74 3076 2 2
3 13 988.56 20 14.69 1703 2 4
4 13 244.40 20 14.80 643 2 4
5 8 0.24 165 14.84 264 2 5

Cycle 177 GMT 27/ 8/2024 12: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 30 14.79 437 2 3
2 7 2006.64 53 14.76 3069 2 2
3 13 985.08 20 14.70 1706 2 4
4 13 243.80 20 14.85 648 2 3
5 8 -0.04 165 14.84 261 2 3

Cycle 176 GMT 17/ 8/2024 17:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 14.78 439 2 3
2 7 2002.88 53 14.74 3066 2 2
3 13 997.16 20 14.68 1705 2 4
4 13 250.48 20 14.84 651 2 3
5 8 0.04 165 14.85 260 2 5
6 14 0.04 30 14.82 260 2 6

Cycle 175 GMT 7/ 8/2024 22:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 30 14.78 427 2 3
2 7 2011.12 53 14.73 3074 2 2
3 13 1009.80 20 14.68 1729 2 3
4 13 261.04 20 14.82 671 2 3
5 8 0.20 165 14.84 263 2 5

Cycle 174 GMT 29/ 7/2024 3:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 30 14.77 441 2 3
2 7 2009.16 53 14.75 3075 2 2
3 13 1003.92 20 14.69 1724 2 4
4 13 269.08 20 14.82 683 2 3
5 8 -0.12 165 14.85 261 2 4
6 14 -0.12 30 14.81 261 2 5

Cycle 173 GMT 19/ 7/2024 8:33:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 30 14.79 417 2 2
2 7 2010.88 52 14.75 3092 2 2
3 13 1004.88 20 14.69 1727 2 3
4 13 243.48 20 14.82 642 2 3
5 8 0.00 165 14.85 262 2 5

Cycle 172 GMT 9/ 7/2024 13:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 14.79 412 2 3
2 7 2003.00 53 14.74 3076 2 2
3 13 896.56 20 14.71 1576 2 3
4 13 296.76 20 14.81 720 2 4
5 8 0.12 165 14.84 263 2 3

Cycle 171 GMT 29/ 6/2024 18: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 30 14.78 434 2 3
2 7 2008.80 53 14.75 3065 2 2
3 13 988.60 20 14.70 1698 2 3
4 13 250.40 20 14.82 651 2 3
5 8 0.12 165 14.84 259 2 4
6 14 0.12 30 14.81 258 2 6

Cycle 170 GMT 19/ 6/2024 23:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 30 14.77 423 2 3
2 7 2003.32 53 14.75 3058 2 2
3 13 995.84 20 14.70 1705 2 4
4 13 259.68 20 14.84 665 2 3
5 8 0.04 165 14.84 257 2 8

Cycle 169 GMT 10/ 6/2024 4:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 30 14.78 429 2 3
2 7 2011.20 53 14.74 3077 2 2
3 13 995.00 20 14.69 1712 2 3
4 13 246.04 20 14.82 641 2 4
5 8 0.16 165 14.84 259 2 7

Cycle 168 GMT 31/ 5/2024 9:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 30 14.80 433 2 3
2 7 2004.76 53 14.75 3060 2 2
3 13 1001.88 20 14.71 1716 2 4
4 13 251.36 20 14.84 654 2 3
5 13 22.72 20 14.87 299 2 3
6 8 0.04 165 14.84 258 2 4

Cycle 167 GMT 21/ 5/2024 14:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 30 14.78 433 2 3
2 7 2003.08 53 14.76 3056 2 2
3 13 996.84 20 14.72 1710 2 3
4 13 246.64 20 14.84 648 2 3
5 8 0.12 165 14.85 259 2 3

Cycle 166 GMT 11/ 5/2024 20: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.79 412 2 3
2 7 2007.16 53 14.76 3080 2 2
3 13 995.32 20 14.71 1707 2 3
4 13 247.96 20 14.84 647 2 4
5 8 -0.16 165 14.84 261 2 5

Cycle 165 GMT 2/ 5/2024 0:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 14.79 436 2 3
2 7 2009.04 53 14.73 3067 2 2
3 13 1002.24 20 14.71 1727 2 3
4 13 250.12 20 14.84 649 2 3
5 8 -0.08 165 14.85 259 2 5

Cycle 164 GMT 22/ 4/2024 6: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 30 14.80 433 2 3
2 7 2002.84 53 14.76 3055 2 2
3 13 998.64 20 14.69 1709 2 4
4 13 246.76 20 14.85 642 2 4
5 8 0.36 165 14.85 259 2 6

Cycle 163 GMT 12/ 4/2024 11:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 14.80 433 2 3
2 7 2003.04 53 14.76 3063 2 2
3 13 994.44 20 14.71 1707 2 3
4 13 237.40 20 14.85 629 2 3
5 13 19.28 20 14.89 294 2 3
6 8 -0.28 165 14.86 257 2 7

Cycle 162 GMT 2/ 4/2024 16:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.79 410 2 3
2 7 2007.56 53 14.76 3068 2 2
3 13 999.20 20 14.70 1714 2 4
4 13 258.76 20 14.84 662 2 3
5 13 21.12 20 14.88 296 2 3
6 8 0.24 165 14.86 259 2 8

Cycle 161 GMT 23/ 3/2024 21:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 14.79 432 2 3
2 7 2008.76 53 14.74 3078 2 2
3 13 989.20 20 14.71 1702 2 4
4 13 243.68 20 14.85 641 2 3
5 13 19.64 20 14.88 294 2 3
6 8 0.04 165 14.84 258 2 6

Cycle 160 GMT 14/ 3/2024 2:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 30 14.80 433 2 3
2 7 2009.52 53 14.76 3078 2 2
3 13 996.64 20 14.70 1712 2 4
4 13 238.72 20 14.83 631 2 3
5 8 -0.04 165 14.85 260 2 5

Cycle 159 GMT 4/ 3/2024 7:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 30 14.78 411 2 3
2 7 2011.60 53 14.76 3080 2 2
3 13 1004.28 20 14.71 1720 2 4
4 13 260.20 20 14.85 665 2 3
5 13 19.76 20 14.89 297 2 3
6 8 0.00 165 14.86 261 2 5

Cycle 158 GMT 23/ 2/2024 12:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 30 14.78 442 2 3
2 7 2008.40 53 14.76 3082 2 2
3 13 1009.32 20 14.72 1732 2 4
4 13 256.32 20 14.86 659 2 3
5 13 20.44 20 14.89 297 2 3
6 8 -0.04 165 14.85 260 2 5

Cycle 157 GMT 13/ 2/2024 18: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 14.79 423 2 3
2 7 2010.56 53 14.77 3071 2 2
3 13 997.92 20 14.71 1714 2 4
4 13 245.76 20 14.86 645 2 3
5 13 17.60 20 14.89 294 2 3
6 8 0.20 165 14.86 260 2 5

Cycle 156 GMT 3/ 2/2024 23:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 30 14.79 429 2 3
2 7 2009.16 52 14.76 3072 2 2
3 13 997.04 20 14.72 1705 2 4
4 13 247.84 20 14.83 645 2 4
5 13 20.88 20 14.88 295 2 3
6 8 -0.12 165 14.85 259 3 5

Cycle 155 GMT 25/ 1/2024 1:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 30 14.81 418 2 3
2 7 2010.96 53 14.76 3076 2 2
3 13 1007.68 20 14.71 1727 2 4
4 13 252.72 20 14.84 651 2 3
5 13 23.68 20 14.89 301 2 3
6 8 -0.04 165 14.85 258 2 7
7 14 -0.04 30 14.83 257 3 6

Cycle 154 GMT 15/ 1/2024 4:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 30 14.80 427 2 3
2 7 2004.80 53 14.78 3079 2 2
3 13 999.44 20 14.71 1714 2 4
4 13 255.88 20 14.84 655 2 3
5 8 0.08 165 14.86 258 2 6
6 14 0.08 30 14.85 254 2 7

Cycle 153 GMT 5/ 1/2024 6:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 30 14.81 426 2 3
2 7 2013.16 53 14.76 3081 2 2
3 13 989.40 20 14.71 1698 2 4
4 13 244.64 20 14.85 639 2 3
5 8 0.12 165 14.87 259 2 6

Cycle 152 GMT 26/12/2023 9:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 30 14.82 437 2 3
2 7 2004.32 53 14.78 3073 2 2
3 13 1017.24 20 14.71 1738 2 3
4 13 267.96 20 14.87 678 2 3
5 8 0.12 165 14.87 258 2 5

Cycle 151 GMT 16/12/2023 11:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 30 14.81 423 2 3
2 7 2009.16 52 14.77 3083 2 2
3 13 990.64 20 14.72 1711 2 3
4 13 251.72 20 14.85 653 2 3
5 8 0.08 165 14.87 260 2 6

Cycle 150 GMT 6/12/2023 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 30 14.81 433 2 3
2 7 2010.20 53 14.75 3083 2 2
3 13 995.80 20 14.72 1715 2 3
4 13 241.84 20 14.86 638 2 3
5 8 0.00 165 14.88 260 2 5

Cycle 149 GMT 26/11/2023 17: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 30 14.82 429 2 3
2 7 2006.36 53 14.77 3080 2 2
3 13 1001.92 20 14.74 1722 2 3
4 13 248.92 20 14.86 649 2 4
5 8 0.04 165 14.88 261 2 6

Cycle 148 GMT 16/11/2023 19:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 30 14.81 433 2 3
2 7 2008.24 53 14.77 3078 2 2
3 13 891.88 20 14.73 1568 2 4
4 13 293.68 20 14.85 718 2 3
5 8 0.12 165 14.87 262 2 7

Cycle 147 GMT 6/11/2023 21:59: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 30 14.83 435 2 3
2 7 2003.92 52 14.77 3071 2 2
3 13 897.20 20 14.76 1578 2 4
4 13 303.44 20 14.85 731 2 3
5 8 0.04 165 14.87 261 2 5

Cycle 146 GMT 28/10/2023 0:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 30 14.83 434 2 3
2 7 2004.36 53 14.77 3074 2 2
3 13 988.24 20 14.71 1700 2 4
4 13 249.16 20 14.87 648 2 3
5 8 0.08 165 14.87 260 2 5

Cycle 145 GMT 18/10/2023 3: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 30 14.83 435 2 3
2 7 2008.60 53 14.77 3067 2 2
3 13 997.20 20 14.72 1716 2 4
4 13 249.32 20 14.87 652 2 4
5 8 0.12 165 14.89 260 2 6

Cycle 144 GMT 8/10/2023 5:38: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 30 14.83 433 2 3
2 7 2010.44 52 14.77 3079 2 2
3 13 889.48 20 14.77 1568 2 4
4 13 184.92 20 14.89 547 2 3
5 8 -0.08 165 14.88 259 2 5

Cycle 143 GMT 28/ 9/2023 7:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 30 14.83 419 2 3
2 7 2002.52 53 14.76 3057 2 2
3 13 883.08 20 14.76 1559 2 3
4 13 287.12 20 14.88 708 2 4
5 8 0.04 165 14.89 260 2 5

Cycle 142 GMT 18/ 9/2023 10:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 14.84 409 2 3
2 7 2010.44 53 14.78 3080 2 2
3 13 893.84 20 14.76 1576 2 3
4 13 297.96 20 14.86 727 2 3
5 8 0.16 165 14.89 259 2 4

Cycle 141 GMT 8/ 9/2023 12:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 14.84 433 2 3
2 7 2005.56 53 14.77 3074 2 2
3 13 997.24 20 14.73 1715 2 3
4 13 250.64 20 14.87 647 2 3
5 8 0.12 165 14.89 257 2 5
6 14 0.12 30 14.86 258 3 6

Cycle 140 GMT 29/ 8/2023 15: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 14.83 420 2 3
2 7 2003.72 53 14.77 3065 2 2
3 13 1006.00 20 14.73 1728 2 3
4 13 258.76 20 14.87 660 2 4
5 8 -0.04 165 14.89 259 2 9

Cycle 139 GMT 19/ 8/2023 17:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 14.84 421 2 3
2 7 2008.08 53 14.78 3078 2 2
3 13 1012.12 20 14.74 1733 2 4
4 13 270.24 20 14.87 683 2 4
5 8 0.28 165 14.89 259 2 8

Cycle 138 GMT 9/ 8/2023 20: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 30 14.83 417 2 3
2 7 2010.68 52 14.79 3088 2 2
3 13 895.12 20 14.75 1574 2 3
4 13 296.96 20 14.87 723 2 3
5 8 -0.24 165 14.89 259 2 5
6 14 -0.24 30 14.86 259 5 6

Cycle 137 GMT 30/ 7/2023 22:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 30 14.83 427 2 3
2 7 2005.88 53 14.77 3066 2 2
3 13 1011.24 20 14.74 1733 2 3
4 13 257.40 20 14.87 660 2 4
5 8 0.32 165 14.89 260 2 6

Cycle 136 GMT 21/ 7/2023 0:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 30 14.83 436 2 3
2 7 2011.28 53 14.78 3078 2 2
3 13 1000.08 20 14.74 1712 2 3
4 13 244.56 20 14.88 641 2 3
5 8 -0.08 165 14.90 257 2 8

Cycle 135 GMT 11/ 7/2023 3:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 14.84 420 2 3
2 7 2009.44 53 14.78 3071 2 2
3 13 1000.28 20 14.75 1720 2 4
4 13 262.68 20 14.87 669 2 4
5 8 0.04 165 14.89 258 2 6
6 14 0.04 30 14.87 259 2 8

Cycle 134 GMT 1/ 7/2023 5:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 30 14.83 433 2 3
2 7 2005.32 53 14.79 3070 2 2
3 13 983.96 20 14.73 1690 2 3
4 13 233.52 20 14.88 626 2 3
5 8 0.28 165 14.90 259 2 7

Cycle 133 GMT 21/ 6/2023 8:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 14.84 412 3 3
2 7 2011.20 53 14.77 3075 2 2
3 13 990.68 20 14.74 1708 2 4
4 13 342.64 20 14.85 789 2 4
5 8 0.00 165 14.89 260 2 5

Cycle 132 GMT 11/ 6/2023 11: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 14.84 410 2 3
2 7 2006.96 53 14.79 3075 2 2
3 13 979.32 20 14.76 1690 2 4
4 13 227.84 20 14.91 618 2 3
5 8 -0.04 165 14.91 259 3 4

Cycle 131 GMT 1/ 6/2023 13:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 30 14.83 432 2 3
2 7 2012.16 53 14.80 3092 2 2
3 13 1007.72 20 14.75 1727 2 4
4 13 249.72 20 14.90 653 2 3
5 8 0.12 165 14.90 259 2 4

Cycle 130 GMT 22/ 5/2023 16: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 14.83 411 2 3
2 7 2009.72 53 14.79 3095 2 2
3 13 996.92 20 14.73 1711 2 3
4 13 249.20 20 14.89 650 2 3
5 8 0.00 165 14.90 259 2 4
6 14 0.00 30 14.87 258 2 5

Cycle 129 GMT 12/ 5/2023 18:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 30 14.83 405 2 3
2 7 2004.32 53 14.78 3069 2 2
3 13 1015.80 20 14.74 1740 2 4
4 13 262.40 20 14.88 669 2 3
5 8 0.00 165 14.89 259 2 4

Cycle 128 GMT 2/ 5/2023 21: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 14.82 428 2 3
2 7 2007.96 53 14.78 3076 2 2
3 13 884.16 20 14.76 1558 2 3
4 13 191.76 20 14.89 562 2 3
5 8 0.04 165 14.89 258 2 5

Cycle 127 GMT 22/ 4/2023 23:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 14.84 431 2 3
2 7 2006.92 53 14.77 3070 2 2
3 13 1004.56 20 14.73 1725 2 3
4 13 248.40 20 14.89 646 2 3
5 8 0.00 165 14.90 259 2 5

Cycle 126 GMT 13/ 4/2023 1:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 30 14.85 428 2 3
2 7 2002.60 53 14.79 3062 2 2
3 13 992.12 20 14.76 1707 2 4
4 13 240.28 20 14.91 636 2 4
5 8 0.36 165 14.91 259 2 7

Cycle 125 GMT 3/ 4/2023 4:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 14.83 428 2 3
2 7 2007.80 53 14.79 3071 2 2
3 13 995.24 20 14.76 1711 2 3
4 13 236.32 20 14.89 628 2 3
5 8 0.00 165 14.90 258 2 4
6 14 0.00 30 14.87 256 2 8

Cycle 124 GMT 24/ 3/2023 6:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 30 14.84 434 2 3
2 7 2005.28 53 14.78 3068 2 2
3 13 996.84 20 14.73 1709 2 4
4 13 224.36 20 14.92 608 2 3
5 13 18.32 20 14.93 290 2 3
6 8 0.00 165 14.90 258 2 6

Cycle 123 GMT 14/ 3/2023 9:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 14.84 405 2 3
2 7 2002.68 53 14.79 3069 2 2
3 13 974.48 20 14.76 1686 2 4
4 13 223.80 20 14.92 611 2 3
5 13 20.32 20 14.94 294 2 3
6 8 0.16 165 14.90 259 2 5

Cycle 122 GMT 4/ 3/2023 12: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 30 14.84 430 2 3
2 7 2009.72 53 14.80 3078 2 2
3 13 986.64 20 14.76 1702 2 4
4 13 237.84 20 14.91 633 2 4
5 13 19.56 20 14.94 295 2 3
6 8 0.00 165 14.91 259 2 8

Cycle 121 GMT 22/ 2/2023 14:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 30 14.83 433 3 3
2 7 2006.28 53 14.79 3067 2 2
3 13 982.36 20 14.76 1695 2 3
4 13 228.92 20 14.91 618 2 3
5 13 18.56 20 14.95 294 2 3
6 8 -0.12 165 14.91 260 2 4

Cycle 120 GMT 12/ 2/2023 17: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 30 14.84 433 2 3
2 7 2007.24 53 14.80 3067 2 2
3 13 886.44 20 14.80 1563 2 3
4 13 287.76 20 14.89 707 2 4
5 13 23.72 20 14.94 301 2 3
6 8 0.12 165 14.91 261 2 6

Cycle 119 GMT 2/ 2/2023 19:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 14.84 428 2 3
2 7 2012.00 52 14.81 3073 2 2
3 13 992.28 20 14.76 1706 2 3
4 13 238.80 20 14.89 634 2 4
5 13 20.72 20 14.92 297 2 3
6 8 -0.08 165 14.90 259 2 5

Cycle 118 GMT 23/ 1/2023 22: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 14.85 405 2 3
2 7 2005.80 52 14.79 3063 2 2
3 13 1001.28 20 14.77 1722 2 3
4 13 238.00 20 14.92 634 2 3
5 13 19.68 20 14.95 296 2 3
6 8 0.00 165 14.91 260 2 5
7 14 0.00 30 14.87 258 2 7

Cycle 117 GMT 14/ 1/2023 0:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 30 14.85 431 2 3
2 7 2010.08 53 14.80 3078 2 2
3 13 880.24 20 14.79 1548 2 4
4 13 280.48 20 14.89 698 2 4
5 13 21.24 20 14.93 299 2 3
6 8 0.08 165 14.90 258 2 9

Cycle 116 GMT 4/ 1/2023 3: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 30 14.86 438 2 3
2 7 2003.36 53 14.79 3073 2 2
3 13 993.72 20 14.77 1708 2 3
4 13 245.32 20 14.92 646 2 3
5 8 0.00 165 14.92 260 2 6

Cycle 115 GMT 25/12/2022 5:37: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 30 14.86 439 2 3
2 7 2010.32 52 14.80 3073 2 3
3 13 1002.56 20 14.76 1723 2 4
4 13 247.96 20 14.92 649 2 3
5 8 0.24 165 14.92 262 2 3

Cycle 114 GMT 15/12/2022 8:14: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 30 14.85 414 2 3
2 7 2005.20 53 14.80 3066 2 2
3 13 994.80 20 14.78 1714 2 3
4 13 247.32 20 14.93 645 2 3
5 8 0.12 165 14.92 261 2 5

Cycle 113 GMT 5/12/2022 10:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 14.86 411 2 3
2 7 2003.72 53 14.82 3076 2 2
3 13 996.60 20 14.78 1714 2 4
4 13 240.96 20 14.90 636 2 4
5 8 -0.08 165 14.93 262 2 4
6 14 -0.08 30 14.89 261 4 5

Cycle 112 GMT 25/11/2022 13:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 14.86 446 2 3
2 7 2007.76 53 14.81 3079 2 2
3 13 990.04 20 14.77 1707 2 4
4 13 250.64 20 14.92 653 2 3
5 8 0.20 165 14.91 259 2 6

Cycle 111 GMT 15/11/2022 15:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 30 14.85 442 2 3
2 7 2006.72 53 14.80 3082 2 2
3 13 1004.52 20 14.77 1725 2 3
4 13 255.48 20 14.92 662 2 4
5 8 0.08 165 14.92 261 2 7

Cycle 110 GMT 5/11/2022 18:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 14.85 439 2 3
2 7 2004.64 52 14.80 3072 2 2
3 13 983.64 20 14.77 1693 2 4
4 13 245.52 20 14.90 645 2 4
5 8 -0.16 165 14.93 260 2 6
6 14 -0.16 30 14.91 260 2 7

Cycle 109 GMT 26/10/2022 20:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 30 14.87 439 2 3
2 7 2011.04 53 14.78 3089 2 2
3 13 994.20 20 14.77 1715 2 4
4 13 238.92 20 14.92 633 2 4
5 8 0.36 165 14.92 261 2 3

Cycle 108 GMT 16/10/2022 23:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 30 14.88 439 2 3
2 7 2005.84 52 14.82 3093 2 2
3 13 870.80 20 14.79 1541 2 4
4 13 276.40 20 14.91 691 2 4
5 8 -0.12 165 14.94 263 2 4

Cycle 107 GMT 7/10/2022 1:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 29 14.87 442 2 3
2 7 2006.20 53 14.83 3079 2 2
3 13 1000.80 20 14.79 1727 2 4
4 13 242.40 20 14.90 642 2 4
5 8 0.20 165 14.93 261 2 6

Cycle 106 GMT 27/ 9/2022 4:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 14.85 442 2 3
2 7 2008.40 53 14.80 3092 2 2
3 13 884.96 20 14.79 1565 2 4
4 13 289.12 20 14.89 714 2 4
5 8 0.00 165 14.93 263 2 4
6 14 0.00 30 14.91 261 2 6

Cycle 105 GMT 17/ 9/2022 6:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 14.86 424 2 3
2 7 2004.88 53 14.79 3072 2 2
3 13 857.32 20 14.80 1523 2 4
4 13 257.24 20 14.91 663 2 3
5 8 0.20 165 14.93 263 2 5

Cycle 104 GMT 7/ 9/2022 9:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 29 14.86 435 2 3
2 7 2006.64 53 14.80 3080 2 2
3 13 872.36 20 14.80 1543 2 4
4 13 274.56 20 14.91 690 2 4
5 8 0.24 165 14.93 264 2 5

Cycle 103 GMT 28/ 8/2022 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 30 14.85 445 2 3
2 7 2009.48 53 14.80 3083 2 2
3 13 990.52 20 14.77 1709 2 3
4 13 247.60 20 14.92 648 2 4
5 13 21.92 20 14.95 298 2 3
6 8 -0.12 165 14.92 261 2 4

Cycle 102 GMT 18/ 8/2022 14: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 14.87 441 2 3
2 7 2008.16 53 14.80 3093 2 2
3 13 975.76 20 14.77 1687 2 4
4 13 218.56 20 14.91 608 2 4
5 8 0.16 165 14.92 263 2 5

Cycle 101 GMT 8/ 8/2022 16:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 30 14.86 442 2 3
2 7 2006.28 53 14.81 3094 2 2
3 13 987.12 20 14.78 1703 2 3
4 13 230.28 20 14.93 623 2 4
5 8 -0.04 165 14.93 261 2 3

Cycle 100 GMT 29/ 7/2022 19: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 14.87 419 2 3
2 7 2008.00 53 14.81 3084 2 2
3 13 995.48 20 14.78 1713 2 4
4 13 247.44 20 14.92 649 2 4
5 8 0.36 165 14.93 262 2 5

Cycle 99 GMT 19/ 7/2022 21:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.86 422 2 3
2 7 2010.20 53 14.81 3092 2 2
3 13 989.12 20 14.78 1704 2 3
4 13 224.48 20 14.91 614 2 4
5 8 0.08 165 14.93 262 2 6

Cycle 98 GMT 10/ 7/2022 0: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 29 14.85 440 2 3
2 7 2006.52 53 14.81 3080 2 2
3 13 872.24 20 14.81 1548 2 3
4 13 270.80 20 14.91 685 2 4
5 8 0.08 165 14.93 261 2 6

Cycle 97 GMT 30/ 6/2022 2:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 30 14.87 424 2 3
2 7 2003.40 53 14.80 3083 2 2
3 13 982.00 20 14.77 1699 2 3
4 13 225.68 20 14.91 615 2 4
5 8 0.32 165 14.93 264 2 8

Cycle 96 GMT 20/ 6/2022 5: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 14.87 425 2 3
2 7 1707.12 53 14.89 2690 2 2
3 13 906.76 20 14.85 1601 2 4
4 13 156.96 20 14.95 509 2 3
5 8 0.24 165 14.95 261 2 5

Cycle 95 GMT 10/ 6/2022 5:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 29 14.86 435 2 3
2 3 1022.32 1 15.00 1839 2 3
3 7 1686.92 53 14.88 2667 2 2
4 13 891.76 20 14.83 1572 2 4
5 13 147.32 20 14.96 494 2 4
6 8 -0.24 165 14.94 260 2 7
7 14 -0.24 30 14.91 259 2 3

Cycle 94 GMT 31/ 5/2022 5:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 25 14.94 431 2 3
2 10 1044.60 2 14.95 1850 2 3
3 10 1083.00 3 14.92 1908 2 3
4 7 1675.56 52 14.87 2650 2 2
5 13 765.08 20 14.84 1395 2 4
6 13 185.24 20 14.95 558 2 4
7 8 0.28 165 14.93 262 2 4

Cycle 93 GMT 21/ 5/2022 5:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 29 14.93 431 2 3
2 3 923.92 -1 15.28 0 2 3
3 3 924.04 -1 15.30 0 2 3
4 7 943.48 52 15.11 1648 2 2
5 13 671.48 20 15.02 1258 2 5
6 13 86.12 20 15.08 398 2 4
7 8 -0.12 165 15.04 260 2 4

Cycle 92 GMT 11/ 5/2022 7:11: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 29 14.86 433 3 3
2 7 1141.76 53 15.06 1915 2 2
3 13 728.12 20 14.98 1342 2 4
4 13 66.60 20 15.04 368 2 3
5 8 0.00 165 15.00 259 2 5

Cycle 91 GMT 1/ 5/2022 8:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 29 14.87 409 3 3
2 7 2006.12 53 14.81 3084 2 2
3 13 985.76 20 14.78 1701 2 4
4 13 219.68 20 14.91 603 2 4
5 8 0.00 165 14.92 260 2 5

Cycle 90 GMT 21/ 4/2022 10:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 29 14.86 407 2 3
2 7 2005.80 53 14.82 3076 2 2
3 13 986.40 20 14.77 1698 2 4
4 13 232.60 20 14.91 626 2 4
5 8 0.00 165 14.93 259 2 6

Cycle 89 GMT 11/ 4/2022 13:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 29 14.85 433 2 3
2 7 2008.64 53 14.81 3089 2 2
3 13 979.88 20 14.78 1690 2 3
4 13 208.40 20 14.91 591 2 3
5 8 0.28 165 14.92 260 2 5

Cycle 88 GMT 1/ 4/2022 15:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 29 14.86 405 2 3
2 7 2002.96 53 14.81 3064 2 2
3 13 997.96 20 14.78 1716 2 4
4 13 238.68 20 14.91 631 2 4
5 13 20.60 20 14.95 294 2 3
6 8 -0.08 165 14.91 259 2 6

Cycle 87 GMT 22/ 3/2022 18:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 14.86 409 2 3
2 7 2002.20 53 14.83 3070 2 2
3 13 980.80 20 14.79 1699 2 3
4 13 231.88 20 14.92 622 2 4
5 13 19.96 20 14.96 295 2 3
6 8 0.12 165 14.92 259 2 7

Cycle 86 GMT 12/ 3/2022 20:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 29 14.85 437 2 3
2 7 2004.48 53 14.82 3073 2 2
3 13 992.20 20 14.78 1705 2 4
4 13 227.76 20 14.95 615 2 3
5 13 21.00 20 14.95 298 2 3
6 8 -0.12 165 14.91 260 2 4

Cycle 85 GMT 2/ 3/2022 23:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 29 14.86 432 2 3
2 7 2002.08 53 14.83 3075 2 2
3 13 976.88 20 14.80 1685 2 4
4 13 228.52 20 14.93 621 2 4
5 13 18.80 20 14.95 293 2 4
6 8 0.24 165 14.93 261 2 7

Cycle 84 GMT 21/ 2/2022 1:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 29 14.86 437 2 3
2 7 2009.16 53 14.82 3080 2 2
3 13 991.12 20 14.78 1711 2 3
4 13 233.56 20 14.92 628 2 4
5 13 19.12 20 14.95 294 2 3
6 8 -0.12 165 14.93 260 2 6

Cycle 83 GMT 11/ 2/2022 4:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 29 14.88 440 2 3
2 7 2007.56 52 14.83 3098 2 2
3 13 984.80 20 14.79 1705 2 3
4 13 226.24 20 14.93 619 2 4
5 8 0.20 165 14.95 262 2 4

Cycle 82 GMT 1/ 2/2022 6:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 29 14.87 434 2 3
2 7 2010.04 53 14.84 3088 2 2
3 13 982.48 20 14.77 1696 2 4
4 13 226.32 20 14.95 617 2 4
5 8 0.20 165 14.95 261 2 5

Cycle 81 GMT 22/ 1/2022 9:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 29 14.87 439 2 3
2 7 2004.24 53 14.84 3092 2 2
3 13 978.88 20 14.80 1697 2 3
4 13 215.84 20 14.94 601 2 3
5 13 16.00 20 14.97 291 2 3
6 8 0.12 165 14.95 263 2 5

Cycle 80 GMT 12/ 1/2022 11:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 29 14.89 438 2 3
2 7 2005.64 52 14.83 3088 2 2
3 13 983.56 20 14.81 1703 2 3
4 13 224.64 20 14.95 618 2 4
5 13 14.60 20 14.97 291 2 3
6 8 -0.04 165 14.94 262 2 6

Cycle 79 GMT 2/ 1/2022 14:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 29 14.89 443 2 3
2 7 2007.44 53 14.87 3090 2 2
3 13 866.48 20 14.84 1544 2 4
4 13 152.56 20 14.97 505 2 3
5 8 0.28 165 14.96 262 2 4

Cycle 78 GMT 23/12/2021 16:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 29 14.91 440 2 3
2 7 2004.60 53 14.82 3072 2 2
3 13 864.60 20 14.82 1534 2 4
4 13 245.84 20 14.96 650 2 3
5 8 -0.04 165 14.96 262 2 4

Cycle 77 GMT 13/12/2021 19:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 14.92 446 2 3
2 7 2002.80 52 14.83 3079 2 2
3 13 880.84 20 14.84 1567 2 4
4 13 158.72 20 14.97 514 2 3
5 8 0.20 165 14.97 263 2 5

Cycle 76 GMT 3/12/2021 21:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 29 14.91 450 2 3
2 7 2007.96 53 14.84 3098 2 2
3 13 985.36 20 14.83 1710 2 4
4 13 213.20 20 14.97 604 2 4
5 8 -0.04 165 14.99 264 2 3

Cycle 75 GMT 24/11/2021 0:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 29 14.93 447 2 3
2 7 2005.56 53 14.83 3077 2 2
3 13 978.68 20 14.81 1700 2 3
4 13 214.76 20 14.97 607 2 4
5 8 0.12 165 14.98 265 2 5

Cycle 74 GMT 14/11/2021 2:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 29 14.93 442 2 3
2 7 2002.12 52 14.83 3075 2 2
3 13 969.80 20 14.84 1689 2 4
4 13 203.12 20 14.98 588 2 4
5 8 0.00 165 14.99 265 2 3

Cycle 73 GMT 4/11/2021 5:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 14.93 444 2 3
2 7 2003.88 53 14.85 3081 2 3
3 13 871.44 20 14.83 1548 2 4
4 13 143.08 20 15.00 493 2 4
5 8 0.08 165 15.01 267 2 5

Cycle 72 GMT 25/10/2021 7:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 29 14.94 455 2 3
2 7 2004.08 53 14.86 3084 2 3
3 13 864.08 20 14.86 1537 2 4
4 13 136.84 20 15.00 480 2 3
5 8 0.12 165 15.00 267 2 3
6 14 0.12 30 14.97 267 2 4

Cycle 71 GMT 15/10/2021 10: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 29 14.95 461 2 3
2 7 2003.36 53 14.88 3089 2 2
3 13 875.32 20 14.87 1555 2 4
4 13 139.68 20 15.02 488 2 4
5 8 -0.04 165 15.02 266 2 4

Cycle 70 GMT 5/10/2021 12:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 29 14.96 434 2 3
2 7 2004.08 52 14.87 3096 2 2
3 13 973.96 20 14.87 1696 2 4
4 13 191.08 20 15.01 571 2 4
5 8 0.04 165 15.02 268 2 5

Cycle 69 GMT 25/ 9/2021 14:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 29 14.97 450 2 3
2 7 2004.88 52 14.87 3107 2 3
3 13 862.92 20 14.88 1543 2 4
4 13 138.40 20 15.03 487 2 3
5 8 -0.08 165 15.03 265 2 5
6 14 -0.08 30 14.99 267 2 6

Cycle 68 GMT 15/ 9/2021 17:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 29 14.96 446 2 3
2 7 2005.96 53 14.86 3090 2 2
3 13 858.24 20 14.87 1529 2 4
4 13 133.64 20 15.03 475 2 3
5 8 0.32 165 15.03 266 2 6
6 14 0.32 30 15.01 265 2 6

Cycle 67 GMT 5/ 9/2021 19:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 29 14.96 450 2 3
2 7 2003.84 53 14.86 3082 2 2
3 13 969.40 20 14.86 1687 2 4
4 13 201.72 20 15.03 585 2 4
5 8 0.04 165 15.03 266 2 4
6 14 0.04 30 15.01 268 2 6

Cycle 66 GMT 26/ 8/2021 22: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 29 14.97 441 2 3
2 7 2006.80 52 14.86 3090 2 3
3 13 971.24 20 14.84 1688 2 4
4 13 200.00 20 15.01 581 2 4
5 8 0.08 165 15.03 268 2 4
6 14 0.08 30 15.00 268 2 6

Cycle 65 GMT 17/ 8/2021 0:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 14.97 439 2 3
2 7 2004.56 53 14.85 3094 2 3
3 13 846.76 20 14.90 1518 2 4
4 13 134.48 20 15.05 479 2 3
5 8 0.00 165 15.04 267 2 6

Cycle 64 GMT 7/ 8/2021 2:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 29 14.99 459 2 3
2 7 2004.16 52 14.87 3091 2 2
3 13 871.44 20 14.89 1551 2 4
4 13 141.76 20 15.06 493 2 3
5 8 -0.04 165 15.05 266 2 3
6 14 -0.04 30 15.03 266 2 5

Cycle 63 GMT 28/ 7/2021 5:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 15.00 440 2 3
2 7 2002.72 53 14.88 3085 2 3
3 13 967.48 20 14.88 1684 2 4
4 13 184.68 20 15.05 565 2 3
5 8 0.24 165 15.06 268 2 4

Cycle 62 GMT 18/ 7/2021 7:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 29 15.00 452 2 3
2 7 2008.08 52 14.89 3093 2 3
3 13 863.00 20 14.90 1539 2 4
4 13 135.52 20 15.04 481 2 4
5 8 -0.08 165 15.06 265 2 3

Cycle 61 GMT 8/ 7/2021 10: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 28 15.00 433 2 3
2 3 1017.04 1 15.08 1834 2 3
3 7 2002.04 53 14.90 3094 2 2
4 13 971.88 20 14.89 1693 2 4
5 13 120.96 20 15.06 458 2 3
6 8 0.12 165 15.05 268 2 4

Cycle 60 GMT 28/ 6/2021 12:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 28 15.01 453 2 3
2 7 2005.52 53 14.90 3093 2 3
3 13 1129.76 20 14.88 1908 2 4
4 13 312.52 20 15.05 754 2 5
5 8 0.12 165 15.07 268 2 7

Cycle 59 GMT 18/ 6/2021 14:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 28 15.02 455 2 3
2 7 2002.88 53 14.89 3095 2 3
3 13 862.24 20 14.94 1541 2 4
4 13 140.12 20 15.09 492 2 4
5 8 0.28 165 15.08 266 2 6
6 14 0.28 30 15.06 267 2 7

Cycle 58 GMT 8/ 6/2021 17:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 28 15.01 455 2 3
2 7 2001.60 53 14.92 3091 2 3
3 13 958.72 20 14.93 1672 2 4
4 13 188.20 20 15.09 567 2 4
5 8 0.20 165 15.09 267 2 6

Cycle 57 GMT 29/ 5/2021 19:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 28 15.02 448 2 3
2 7 2004.36 52 14.89 3092 2 2
3 13 858.16 20 14.95 1536 2 4
4 13 134.76 20 15.08 483 2 4
5 8 -0.16 165 15.09 268 2 3
6 14 -0.16 30 15.07 268 2 5

Cycle 56 GMT 19/ 5/2021 22: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 28 15.03 440 2 3
2 7 2007.64 53 14.90 3101 2 3
3 13 973.68 20 14.90 1691 2 5
4 13 188.28 20 15.08 566 2 4
5 8 0.24 165 15.09 266 2 8

Cycle 55 GMT 10/ 5/2021 0:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 28 15.04 446 2 3
2 7 2008.40 53 14.89 3095 2 2
3 13 850.16 20 14.96 1521 2 4
4 13 135.72 20 15.11 483 2 3
5 8 0.00 165 15.09 265 2 5
6 14 0.00 30 15.07 265 3 5

Cycle 54 GMT 30/ 4/2021 2:55: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 28 15.02 445 2 3
2 7 2006.32 52 14.91 3100 2 2
3 13 867.72 20 14.95 1547 2 4
4 13 145.36 20 15.11 498 2 4
5 8 0.20 165 15.10 266 2 5

Cycle 53 GMT 20/ 4/2021 5:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 28 15.03 451 2 3
2 7 2006.56 53 14.91 3096 2 3
3 13 969.64 20 14.92 1690 2 4
4 13 197.64 20 15.09 579 2 4
5 8 0.04 165 15.10 266 2 4

Cycle 52 GMT 10/ 4/2021 7:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 28 15.04 446 2 3
2 7 2006.12 52 14.92 3081 2 2
3 13 851.32 20 14.96 1518 2 4
4 13 126.16 20 15.12 465 2 4
5 8 0.16 165 15.11 266 2 5

Cycle 51 GMT 31/ 3/2021 10:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 28 15.04 446 2 3
2 7 2004.64 53 14.91 3087 2 2
3 13 856.12 20 14.96 1528 2 4
4 13 235.48 20 15.10 640 2 4
5 8 0.24 165 15.09 267 2 4

Cycle 50 GMT 21/ 3/2021 12:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 28 15.04 441 2 3
2 7 2004.28 53 14.91 3090 2 2
3 13 973.00 20 14.94 1693 2 3
4 13 192.28 20 15.11 571 2 4
5 8 0.16 165 15.11 266 2 6

Cycle 49 GMT 11/ 3/2021 15: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 28 15.04 439 2 3
2 7 2002.60 52 14.94 3078 2 2
3 13 979.96 20 14.94 1703 2 3
4 13 198.44 20 15.11 579 2 4
5 8 0.12 165 15.11 266 2 6

Cycle 48 GMT 1/ 3/2021 17:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 28 15.04 443 2 3
2 7 2003.56 53 14.92 3090 2 3
3 13 846.32 20 14.98 1518 2 4
4 13 222.16 20 15.09 615 2 4
5 8 0.12 165 15.11 265 2 4

Cycle 47 GMT 19/ 2/2021 20:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 28 15.04 438 2 3
2 7 2006.80 53 14.93 3094 2 2
3 13 969.04 20 14.93 1687 2 4
4 13 196.20 20 15.12 579 2 3
5 8 0.20 165 15.11 265 2 4

Cycle 46 GMT 9/ 2/2021 22:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 28 15.02 436 2 3
2 7 2005.12 53 14.91 3096 2 3
3 13 863.24 20 14.96 1543 2 4
4 13 139.80 20 15.10 486 2 3
5 8 0.16 165 15.10 264 2 5

Cycle 45 GMT 31/ 1/2021 1: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 28 15.04 450 2 3
2 7 2003.48 53 14.91 3093 2 3
3 13 855.52 20 14.95 1526 2 4
4 13 141.24 20 15.08 490 2 3
5 8 0.12 165 15.09 264 2 5

Cycle 44 GMT 21/ 1/2021 3:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 28 15.04 444 2 3
2 7 2004.00 53 14.92 3086 2 2
3 13 848.48 20 14.97 1515 2 3
4 13 234.16 20 15.08 634 2 3
5 8 0.00 165 15.10 266 2 5

Cycle 43 GMT 11/ 1/2021 5:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 28 15.05 450 2 3
2 7 2003.68 53 14.90 3094 2 3
3 13 856.52 20 14.96 1531 2 3
4 13 137.04 20 15.13 483 2 3
5 8 0.08 165 15.12 265 2 5

Cycle 42 GMT 1/ 1/2021 8: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 28 15.05 450 2 3
2 7 2001.68 53 14.92 3094 2 3
3 13 962.52 20 14.94 1680 2 4
4 13 194.96 20 15.12 577 2 3
5 8 0.12 165 15.12 266 2 3
6 14 0.12 30 15.08 265 3 4

Cycle 41 GMT 22/12/2020 10:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 28 15.06 441 2 3
2 7 2003.80 53 14.93 3088 2 3
3 13 967.04 20 14.97 1687 2 4
4 13 196.60 20 15.13 581 2 4
5 8 0.12 165 15.12 267 2 7

Cycle 40 GMT 12/12/2020 12:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 28 15.06 451 2 3
2 7 2003.76 53 14.92 3088 2 3
3 13 847.68 20 14.98 1515 2 4
4 13 138.92 20 15.15 488 2 4
5 8 0.28 165 15.13 267 2 3

Cycle 39 GMT 2/12/2020 15:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 28 15.07 449 2 3
2 7 2002.44 53 14.93 3097 2 3
3 13 854.00 20 15.00 1529 2 4
4 13 234.32 20 15.13 637 2 4
5 8 -0.08 165 15.13 266 2 6

Cycle 38 GMT 22/11/2020 17:41: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 28 15.07 445 2 3
2 7 2003.04 52 14.93 3091 2 2
3 13 966.36 20 14.98 1686 2 4
4 13 192.20 20 15.13 571 2 4
5 8 0.04 165 15.13 266 2 4

Cycle 37 GMT 12/11/2020 20: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 28 15.07 447 2 3
2 7 2004.04 52 14.93 3090 2 3
3 13 968.96 20 14.97 1694 2 3
4 13 204.36 20 15.10 589 2 4
5 8 0.16 165 15.14 266 2 4

Cycle 36 GMT 2/11/2020 22:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 28 15.07 453 2 3
2 7 2004.32 53 14.94 3098 2 3
3 13 965.28 20 14.96 1682 2 4
4 13 196.12 20 15.14 578 2 3
5 8 0.08 165 15.14 268 2 4

Cycle 35 GMT 24/10/2020 1: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 28 15.06 443 2 3
2 7 2009.64 53 14.94 3102 2 3
3 13 862.56 20 14.99 1538 2 3
4 13 147.44 20 15.14 500 2 3
5 8 0.00 165 15.14 264 2 9

Cycle 34 GMT 14/10/2020 3: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 28 15.06 447 2 3
2 7 2005.64 53 14.93 3100 2 3
3 13 866.76 20 14.99 1541 2 4
4 13 141.84 20 15.13 491 2 4
5 8 0.16 165 15.13 264 2 5

Cycle 33 GMT 4/10/2020 5:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 28 15.08 453 2 3
2 7 2003.28 53 14.94 3101 2 3
3 13 964.44 20 14.95 1682 2 4
4 13 188.28 20 15.13 566 2 3
5 8 0.16 165 15.13 267 2 9

Cycle 32 GMT 24/ 9/2020 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 28 15.07 446 2 3
2 7 2003.92 53 14.96 3123 2 3
3 13 858.08 20 15.01 1532 2 4
4 13 151.56 20 15.16 511 2 3
5 8 0.08 165 15.14 266 2 5

Cycle 31 GMT 14/ 9/2020 10:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 15.08 448 2 3
2 7 2003.52 53 14.94 3083 2 3
3 13 848.48 20 14.98 1518 2 4
4 13 137.52 20 15.12 487 2 3
5 8 0.16 165 15.14 267 2 3

Cycle 30 GMT 4/ 9/2020 12:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 28 15.09 456 2 3
2 7 2003.56 53 14.93 3088 2 3
3 13 847.00 20 15.02 1520 2 4
4 13 230.72 20 15.13 629 2 4
5 8 0.04 165 15.14 270 2 3

Cycle 29 GMT 25/ 8/2020 15: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 28 15.08 453 2 3
2 7 2006.04 53 14.95 3095 2 3
3 13 831.96 20 15.00 1491 2 4
4 13 202.32 20 15.14 586 2 3
5 8 -0.04 165 15.16 267 2 4

Cycle 28 GMT 15/ 8/2020 17:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 28 15.08 454 2 3
2 7 2007.32 53 14.96 3097 2 3
3 13 846.92 20 15.01 1517 2 4
4 13 228.32 20 15.14 630 2 4
5 8 0.24 165 15.15 269 2 4

Cycle 27 GMT 5/ 8/2020 20:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 28 15.09 455 2 3
2 7 2001.88 53 14.95 3095 2 3
3 13 840.08 20 15.02 1514 2 3
4 13 218.60 20 15.13 615 2 4
5 8 0.00 165 15.15 269 2 5

Cycle 26 GMT 26/ 7/2020 22:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 28 15.10 451 2 3
2 7 2002.12 53 14.95 3088 2 3
3 13 844.76 20 15.01 1516 2 5
4 13 217.64 20 15.15 614 2 4
5 8 0.08 165 15.16 266 2 6

Cycle 25 GMT 17/ 7/2020 1: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 28 15.10 453 2 3
2 7 2003.48 53 14.95 3093 2 3
3 13 953.72 20 15.00 1674 2 4
4 13 174.88 20 15.17 546 2 3
5 8 0.12 165 15.16 268 2 5

Cycle 24 GMT 7/ 7/2020 3:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 28 15.10 452 2 3
2 7 2004.20 53 14.96 3102 2 3
3 13 956.12 20 15.01 1676 2 4
4 13 178.12 20 15.16 554 2 4
5 8 0.12 165 15.17 270 2 4

Cycle 23 GMT 27/ 6/2020 5:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 15.09 430 2 3
2 7 2004.24 53 14.95 3094 2 3
3 13 834.56 20 15.03 1506 2 4
4 13 119.52 20 15.17 458 2 3
5 8 0.08 165 15.17 267 2 5
6 14 0.08 30 15.15 268 2 6

Cycle 22 GMT 17/ 6/2020 8:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 28 15.10 429 2 3
2 7 2001.96 53 14.97 3099 2 3
3 13 829.88 20 15.02 1494 2 4
4 13 118.52 20 15.17 457 2 3
5 8 -0.24 165 15.15 267 2 6
6 14 -0.24 30 15.13 267 2 4

Cycle 21 GMT 7/ 6/2020 10:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 28 15.11 452 2 3
2 7 2005.16 53 14.96 3102 2 3
3 13 845.44 20 15.03 1520 2 4
4 13 127.72 20 15.18 472 2 3
5 8 0.28 165 15.16 268 2 5

Cycle 20 GMT 28/ 5/2020 12:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 28 15.11 429 2 3
2 7 2004.64 53 14.97 3100 2 3
3 13 961.12 20 15.01 1680 2 5
4 13 160.92 20 15.19 528 2 3
5 8 0.16 165 15.18 268 2 5
6 14 0.16 30 15.16 267 2 4

Cycle 19 GMT 18/ 5/2020 15:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 28 15.11 455 2 3
2 7 2002.36 53 14.97 3100 2 3
3 13 959.32 20 15.01 1680 2 4
4 13 170.60 20 15.18 541 2 4
5 8 0.12 165 15.18 270 2 4

Cycle 18 GMT 8/ 5/2020 17:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 28 15.11 435 2 3
2 7 2007.68 53 14.98 3104 2 3
3 13 842.32 20 15.05 1510 2 4
4 13 124.36 20 15.18 467 2 3
5 8 0.04 165 15.19 269 2 4

Cycle 17 GMT 28/ 4/2020 20: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 28 15.11 455 2 3
2 7 2002.64 53 14.98 3083 2 4
3 13 957.00 20 15.03 1670 2 4
4 13 171.28 20 15.19 543 2 3
5 8 -0.08 165 15.18 268 2 7
6 14 -0.08 75 15.15 265 2 8

Cycle 16 GMT 18/ 4/2020 22:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 15.12 427 2 3
2 7 2002.84 53 14.96 3085 2 3
3 13 831.12 20 15.05 1495 2 4
4 13 116.76 20 15.19 455 2 3
5 8 0.20 165 15.17 268 2 4

Cycle 15 GMT 9/ 4/2020 0:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 27 15.12 449 2 3
2 7 2004.68 53 14.98 3095 2 3
3 13 958.88 20 15.03 1680 2 5
4 13 166.60 20 15.19 536 2 4
5 8 0.04 165 15.18 269 2 7

Cycle 14 GMT 30/ 3/2020 3:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 27 15.12 426 2 3
2 7 2002.56 53 15.00 3100 2 3
3 13 822.16 20 15.06 1480 2 4
4 13 113.60 20 15.20 449 2 3
5 8 -0.04 165 15.18 268 2 5

Cycle 13 GMT 20/ 3/2020 5:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 27 15.13 428 2 3
2 7 2002.52 52 14.98 3079 2 3
3 13 955.40 20 15.03 1674 2 6
4 13 163.16 20 15.19 530 2 4
5 8 0.20 165 15.19 269 2 4

Cycle 12 GMT 10/ 3/2020 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 27 15.13 443 2 3
2 7 2005.64 52 15.00 3104 2 3
3 13 826.72 20 15.04 1491 2 5
4 13 117.84 20 15.21 458 2 4
5 8 0.12 165 15.19 271 2 4

Cycle 11 GMT 29/ 2/2020 10:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 27 15.13 448 2 3
2 7 2004.76 53 15.01 3100 2 3
3 13 964.28 18 15.04 1684 2 4
4 13 205.88 18 15.19 594 2 3
5 13 18.84 18 15.23 305 2 3
6 8 0.16 165 15.19 271 2 4

Cycle 10 GMT 19/ 2/2020 12:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 27 15.13 455 2 3
2 7 2009.00 52 15.02 3115 2 4
3 13 837.44 18 15.08 1504 2 4
4 13 225.88 18 15.20 628 2 3
5 13 17.28 18 15.22 302 2 3
6 8 -0.04 165 15.18 269 2 4

Cycle 9 GMT 9/ 2/2020 15: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 27 15.14 452 2 3
2 7 2006.64 53 15.00 3098 2 4
3 13 837.12 18 15.07 1507 2 4
4 13 135.00 18 15.21 486 2 3
5 8 0.00 165 15.20 269 2 6

Cycle 8 GMT 30/ 1/2020 17:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 27 15.14 452 2 3
2 7 2003.88 53 15.04 3111 2 3
3 13 823.36 18 15.07 1488 2 4
4 13 114.48 18 15.23 457 2 3
5 8 0.16 165 15.21 271 2 5

Cycle 7 GMT 20/ 1/2020 19:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 27 15.14 460 2 3
2 7 2003.20 53 15.01 3101 2 3
3 13 825.72 18 15.09 1496 2 6
4 13 215.00 18 15.19 613 2 3
5 8 0.04 165 15.20 273 2 5

Cycle 6 GMT 10/ 1/2020 21:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 26 15.13 452 2 3
2 3 1055.28 2 15.18 1887 2 5
3 7 2005.24 53 15.02 3095 2 4
4 13 823.60 18 15.07 1486 2 4
5 13 212.68 18 15.21 609 2 3
6 8 0.00 165 15.20 274 2 4

Cycle 5 GMT 1/ 1/2020 0: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 25 15.15 446 2 3
2 10 1010.80 2 15.14 1803 2 3
3 7 2003.32 53 15.02 3089 2 3
4 13 834.52 18 15.08 1506 2 5
5 13 212.80 18 15.19 613 2 3
6 8 0.00 165 15.19 273 2 5

Cycle 4 GMT 22/12/2019 2:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 25 15.14 453 2 2
2 7 1505.88 74 14.93 2393 2 4
3 13 76.28 18 15.24 393 2 3
4 8 0.24 165 15.21 271 2 6

Cycle 3 GMT 21/12/2019 2:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 25 15.15 445 2 3
2 3 1029.32 1 15.22 1863 2 4
3 7 1522.56 74 14.92 2415 2 3
4 13 88.28 18 15.23 413 2 3
5 8 -0.04 165 15.22 271 2 4

Cycle 2 GMT 20/12/2019 3:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 26 15.18 439 2 3
2 3 965.40 -1 15.49 0 2 3
3 7 1520.60 74 14.92 2409 2 3
4 13 79.04 18 15.25 393 2 3
5 8 -0.04 165 15.21 270 2 5

Cycle 1 GMT 19/12/2019 3:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 23 15.35 413 2 3
2 3 1079.24 2 15.19 1916 2 3
3 7 996.72 74 15.07 1685 2 4
4 8 0.00 165 15.24 269 2 8

Cycle 0 GMT 18/12/2019 17:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.28 22 15.46 340 3 3
2 7 71.12 74 15.43 351 3 3
3 8 0.20 240 15.42 235 3 11