SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8825 WMO= 3902177


Cycle 189 GMT 25/12/2024 14:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 31 14.92 436 2 3
2 7 2003.64 53 14.74 3064 2 2
3 13 1025.20 17 14.73 1764 2 3
4 13 461.16 17 14.88 973 2 3
5 13 75.20 17 14.98 400 2 3
6 8 0.12 175 14.97 278 2 3

Cycle 188 GMT 15/12/2024 19:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 31 14.92 462 2 3
2 7 2003.60 53 14.75 3068 2 2
3 13 1030.24 17 14.73 1762 2 3
4 13 588.96 17 14.83 1152 2 3
5 13 60.60 17 14.99 373 2 3
6 8 0.08 175 14.97 276 2 5

Cycle 187 GMT 6/12/2024 1:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 31 14.92 478 3 3
2 7 2003.28 53 14.75 3060 2 2
3 13 1025.40 17 14.74 1757 2 3
4 13 462.20 17 14.88 976 2 3
5 13 73.92 17 14.99 401 2 4
6 8 0.08 175 14.97 279 2 4

Cycle 186 GMT 26/11/2024 6:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 31 14.92 473 3 3
2 7 2002.56 53 14.74 3069 2 2
3 13 1018.96 17 14.74 1750 2 3
4 13 453.28 17 14.89 966 2 3
5 13 73.48 17 14.98 405 2 3
6 8 0.04 175 14.97 283 2 6

Cycle 185 GMT 16/11/2024 11:46: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 31 14.92 468 3 3
2 7 2013.96 53 14.74 3087 2 2
3 13 1037.96 17 14.74 1784 2 3
4 13 471.72 17 14.88 990 2 3
5 13 81.08 17 14.98 411 2 3
6 8 0.20 175 14.97 278 2 4

Cycle 184 GMT 6/11/2024 16:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 31 14.91 472 2 3
2 7 2005.64 53 14.75 3075 2 2
3 13 1032.68 17 14.74 1769 2 3
4 13 461.32 17 14.88 975 2 3
5 13 73.48 17 14.99 404 2 3
6 8 0.12 175 14.97 277 2 3

Cycle 183 GMT 27/10/2024 22:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 31 14.93 466 2 3
2 7 2006.68 53 14.74 3077 2 3
3 13 1032.00 17 14.74 1768 2 3
4 13 470.68 17 14.88 989 2 3
5 13 73.44 17 14.99 402 2 3
6 8 0.24 175 14.97 279 2 3

Cycle 182 GMT 18/10/2024 3:30:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 31 14.92 468 2 3
2 7 2006.04 53 14.75 3064 2 2
3 13 1041.04 17 14.74 1781 2 3
4 13 471.44 17 14.88 990 2 3
5 13 77.44 17 14.99 407 2 3
6 8 -0.08 175 14.97 282 2 5
7 14 -0.08 20 14.95 280 2 4

Cycle 181 GMT 8/10/2024 8:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 30 14.92 472 3 3
2 7 2003.68 53 14.73 3063 2 2
3 13 1038.48 17 14.74 1778 2 3
4 13 466.68 17 14.88 984 2 3
5 13 75.80 17 14.99 408 2 3
6 8 0.20 175 14.97 284 2 4

Cycle 180 GMT 28/ 9/2024 13:48:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 14.92 465 2 3
2 7 2006.24 53 14.74 3061 2 2
3 13 1032.24 17 14.75 1765 2 3
4 13 467.68 17 14.89 984 2 3
5 13 75.76 17 14.99 407 2 3
6 8 -0.04 175 14.98 282 2 5

Cycle 179 GMT 18/ 9/2024 19: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 30 14.92 468 2 3
2 7 2011.40 53 14.73 3073 2 2
3 13 1021.08 17 14.75 1749 2 3
4 13 448.32 17 14.89 953 2 3
5 13 67.32 17 15.00 396 2 3
6 8 0.04 175 14.97 285 2 4

Cycle 178 GMT 9/ 9/2024 0:14: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 30 14.93 469 2 3
2 7 2003.60 53 14.76 3049 2 2
3 13 1032.16 17 14.75 1765 2 3
4 13 464.52 17 14.88 976 2 3
5 13 74.56 17 15.00 404 2 3
6 8 0.04 175 14.98 284 2 3

Cycle 177 GMT 30/ 8/2024 5:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 30 14.92 476 2 3
2 7 2003.76 52 14.76 3076 2 2
3 13 1025.84 17 14.74 1753 2 3
4 13 458.24 17 14.89 968 2 3
5 13 69.24 17 15.00 388 2 3
6 8 -0.04 175 14.97 280 2 4

Cycle 176 GMT 20/ 8/2024 10:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 14.93 452 2 3
2 7 2003.76 53 14.77 3051 2 2
3 13 1027.52 17 14.75 1764 2 3
4 13 457.08 17 14.89 973 2 3
5 13 69.84 17 15.00 398 2 2
6 8 0.28 175 14.98 281 2 4

Cycle 175 GMT 10/ 8/2024 15:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 14.93 453 2 3
2 7 2004.28 52 14.76 3076 2 2
3 13 1037.16 17 14.74 1768 2 3
4 13 350.24 17 14.93 817 2 3
5 13 51.28 17 15.01 368 2 3
6 8 0.40 175 14.97 287 2 6

Cycle 174 GMT 31/ 7/2024 21: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 31 14.92 469 2 3
2 7 2005.32 53 14.76 3082 2 2
3 13 1024.16 17 14.75 1751 2 3
4 13 448.92 17 14.89 959 2 3
5 13 36.28 17 15.01 341 2 2
6 8 -0.16 175 14.98 281 2 3
7 14 -0.16 20 14.96 282 2 4

Cycle 173 GMT 22/ 7/2024 2:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 31 14.93 466 2 3
2 7 2004.92 53 14.75 3058 2 2
3 13 1028.80 17 14.75 1753 2 3
4 13 463.72 17 14.88 973 2 3
5 13 72.28 17 15.00 400 2 3
6 8 0.12 175 14.98 281 2 6

Cycle 172 GMT 12/ 7/2024 7:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 31 14.92 445 2 3
2 7 2011.08 53 14.74 3075 2 2
3 13 1031.80 17 14.75 1766 2 3
4 13 468.60 17 14.89 987 2 3
5 13 37.84 17 15.01 342 2 3
6 8 -0.20 175 14.98 281 2 4

Cycle 171 GMT 2/ 7/2024 12:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 31 14.92 451 2 3
2 7 2006.28 53 14.76 3060 2 2
3 13 1023.16 17 14.75 1745 2 3
4 13 457.36 17 14.90 964 2 3
5 13 67.60 17 15.00 390 2 3
6 8 0.16 175 14.98 281 2 5

Cycle 170 GMT 22/ 6/2024 17:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 31 14.94 461 2 3
2 7 2004.76 53 14.80 3075 2 2
3 13 1026.80 17 14.77 1756 2 3
4 13 454.60 17 14.89 966 2 3
5 13 68.36 17 15.00 392 2 3
6 8 -0.08 175 14.97 282 2 3
7 14 -0.08 20 14.96 279 2 7

Cycle 169 GMT 12/ 6/2024 22:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 31 14.93 448 2 3
2 7 2009.00 53 14.76 3082 2 2
3 13 1036.92 17 14.76 1768 2 3
4 13 460.52 17 14.90 974 2 3
5 13 71.04 17 15.01 399 2 3
6 8 0.48 175 14.98 284 2 3
7 14 0.48 20 14.96 284 2 5

Cycle 168 GMT 3/ 6/2024 3:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 31 14.92 466 3 3
2 7 2009.76 52 14.76 3077 2 2
3 13 1034.48 17 14.75 1764 2 3
4 13 461.20 17 14.90 971 2 3
5 13 69.72 17 15.01 394 2 3
6 13 15.04 17 15.02 306 2 3
7 8 -0.32 175 14.97 280 2 4
8 14 -0.32 20 14.95 278 2 8

Cycle 167 GMT 24/ 5/2024 8:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 31 14.91 461 3 3
2 7 2003.56 53 14.74 3066 2 2
3 13 1026.68 17 14.74 1758 2 3
4 13 589.08 17 14.85 1157 2 3
5 13 63.48 17 15.00 386 2 3
6 8 0.04 175 14.97 283 2 5
7 14 0.04 20 14.95 282 2 5

Cycle 166 GMT 14/ 5/2024 13:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 31 14.90 445 3 3
2 7 2006.64 53 14.78 3059 2 2
3 13 1027.64 17 14.75 1763 2 3
4 13 459.56 17 14.87 970 2 3
5 13 69.60 17 14.98 392 2 3
6 8 0.12 175 14.96 281 2 3
7 14 0.12 20 14.94 281 2 5

Cycle 165 GMT 4/ 5/2024 18:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 31 14.90 468 3 3
2 7 2003.24 53 14.83 3064 2 2
3 13 1029.64 17 14.79 1761 2 3
4 13 451.08 17 14.89 960 2 3
5 13 66.28 17 14.99 391 2 3
6 8 0.12 175 14.96 282 2 4

Cycle 164 GMT 24/ 4/2024 23:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 31 14.91 433 3 3
2 7 2003.52 53 14.82 3063 2 2
3 13 1025.08 17 14.79 1756 2 3
4 13 453.12 17 14.90 967 2 3
5 13 71.00 17 14.99 402 2 3
6 8 0.00 175 14.96 284 2 3

Cycle 163 GMT 15/ 4/2024 4:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 30 14.91 457 2 3
2 7 2009.96 53 14.83 3082 2 2
3 13 1032.56 17 14.78 1763 2 3
4 13 458.32 17 14.90 970 2 3
5 13 40.04 17 15.00 345 2 3
6 8 0.12 175 14.97 277 2 3
7 14 0.12 20 14.94 278 2 7

Cycle 162 GMT 5/ 4/2024 9:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 30 14.92 430 3 3
2 7 2003.84 52 14.83 3057 2 2
3 13 1018.28 17 14.80 1749 2 3
4 13 456.36 17 14.90 963 2 3
5 13 68.20 17 15.00 390 2 3
6 8 0.08 175 14.97 281 2 5

Cycle 161 GMT 26/ 3/2024 14:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 30 14.90 469 3 3
2 7 2002.96 53 14.83 3068 2 2
3 13 1033.28 17 14.79 1773 2 3
4 13 464.44 17 14.90 988 2 3
5 13 74.04 17 15.00 401 2 3
6 8 -0.04 175 14.97 280 2 4

Cycle 160 GMT 16/ 3/2024 20: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 14.91 432 3 3
2 7 2004.76 53 14.82 3056 2 2
3 13 1030.64 17 14.78 1759 2 3
4 13 451.92 17 14.89 956 2 3
5 13 67.88 17 15.00 398 2 3
6 8 0.04 175 14.96 285 2 3

Cycle 159 GMT 7/ 3/2024 0:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 14.92 446 3 3
2 7 2002.80 53 14.82 3053 2 2
3 13 1021.76 17 14.78 1750 2 3
4 13 444.28 17 14.89 949 2 3
5 13 68.72 17 14.99 396 2 3
6 8 0.04 175 14.96 282 2 4

Cycle 158 GMT 26/ 2/2024 5:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 14.92 438 3 3
2 7 2004.92 53 14.83 3064 2 2
3 13 1028.84 17 14.79 1758 2 3
4 13 457.16 17 14.90 971 2 3
5 13 70.40 17 15.00 397 2 3
6 8 0.04 175 14.97 287 2 4

Cycle 157 GMT 16/ 2/2024 10:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 30 14.92 461 3 3
2 7 2004.20 53 14.83 3058 2 2
3 13 1020.20 17 14.80 1740 2 3
4 13 452.72 17 14.91 965 2 3
5 13 68.48 17 15.00 394 2 3
6 8 0.12 175 14.97 286 2 3

Cycle 156 GMT 6/ 2/2024 15:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 30 14.93 437 3 3
2 7 2003.36 53 14.84 3062 2 2
3 13 1025.56 17 14.80 1759 2 3
4 13 455.84 17 14.91 964 2 3
5 13 37.76 17 15.02 342 2 3
6 8 0.04 175 14.98 283 2 3

Cycle 155 GMT 27/ 1/2024 20:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 30 14.93 465 3 3
2 7 2009.68 53 14.83 3075 2 2
3 13 1028.12 17 14.79 1753 2 3
4 13 463.72 17 14.91 978 2 3
5 13 72.56 17 15.01 403 2 3
6 8 0.00 175 14.99 281 2 4

Cycle 154 GMT 17/ 1/2024 23:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 30 14.92 439 3 3
2 7 2003.44 53 14.84 3059 2 2
3 13 1012.08 17 14.81 1744 2 3
4 13 448.12 17 14.92 953 2 3
5 13 35.40 17 15.02 343 2 2
6 8 0.12 175 14.99 286 2 3

Cycle 153 GMT 8/ 1/2024 1:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 30 14.93 475 2 3
2 7 2010.72 53 14.82 3064 2 2
3 13 1035.28 17 14.80 1776 2 3
4 13 455.48 17 14.92 966 2 3
5 13 36.36 17 15.02 343 2 3
6 8 0.20 175 14.98 288 2 5

Cycle 152 GMT 29/12/2023 4:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 30 14.92 470 2 3
2 7 2004.44 52 14.84 3070 2 2
3 13 1022.12 17 14.79 1752 2 4
4 13 445.60 17 14.91 961 2 3
5 13 65.52 17 15.00 387 2 3
6 8 0.12 175 14.98 289 2 5

Cycle 151 GMT 19/12/2023 7: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 14.92 436 2 3
2 7 2007.88 53 14.84 3062 2 2
3 13 1036.72 17 14.80 1769 2 3
4 13 460.04 17 14.91 972 2 3
5 13 40.48 17 15.02 349 2 3
6 8 0.16 175 14.98 287 2 3

Cycle 150 GMT 9/12/2023 9:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 14.93 443 3 3
2 7 2004.16 53 14.84 3058 2 2
3 13 1026.28 17 14.80 1749 2 3
4 13 458.44 17 14.92 967 2 3
5 13 37.00 17 15.02 338 2 3
6 8 0.04 175 14.98 281 2 3

Cycle 149 GMT 29/11/2023 12: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 30 14.93 471 2 3
2 7 2004.76 53 14.83 3071 2 2
3 13 1018.88 17 14.80 1757 2 3
4 13 453.20 17 14.92 967 2 3
5 13 35.28 17 15.02 341 2 3
6 8 0.12 175 14.98 284 2 4

Cycle 148 GMT 19/11/2023 14:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 30 14.93 473 2 3
2 7 2004.32 52 14.85 3065 2 2
3 13 1024.56 17 14.81 1756 2 3
4 13 463.96 17 14.91 979 2 3
5 13 71.40 17 15.01 401 2 4
6 8 0.12 175 14.98 287 2 5

Cycle 147 GMT 9/11/2023 17:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 30 14.93 473 2 3
2 7 2004.04 52 14.83 3059 2 2
3 13 1024.04 17 14.81 1752 2 4
4 13 454.60 17 14.92 968 2 3
5 13 37.08 17 15.03 349 2 2
6 8 0.16 175 14.98 289 2 4

Cycle 146 GMT 30/10/2023 19:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 30 14.93 474 2 3
2 7 2004.44 54 14.84 3062 2 2
3 13 1013.92 17 14.80 1751 2 3
4 13 433.72 17 14.92 935 2 3
5 13 60.08 17 15.02 377 2 3
6 8 0.24 175 14.99 283 2 3

Cycle 145 GMT 20/10/2023 22:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 14.93 464 2 3
2 7 2002.64 53 14.83 3057 2 2
3 13 1021.12 17 14.80 1757 2 3
4 13 456.44 17 14.91 971 2 3
5 13 67.24 17 15.02 388 2 4
6 8 0.04 175 14.99 283 2 3

Cycle 144 GMT 11/10/2023 1: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 30 14.94 474 2 3
2 7 2003.32 53 14.84 3077 2 2
3 13 1019.80 17 14.81 1757 2 3
4 13 456.12 17 14.92 974 2 3
5 13 34.56 17 15.03 344 2 2
6 8 -0.04 175 14.99 282 2 3

Cycle 143 GMT 1/10/2023 3:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 14.94 467 2 3
2 7 2012.96 52 14.84 3073 2 2
3 13 1038.72 17 14.81 1784 2 3
4 13 466.20 17 14.92 989 2 3
5 13 75.04 17 15.02 409 2 3
6 8 0.20 175 14.99 283 2 4

Cycle 142 GMT 21/ 9/2023 6: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 30 14.94 475 2 3
2 7 2003.84 53 14.85 3065 2 2
3 13 1023.96 17 14.82 1765 2 3
4 13 458.40 17 14.93 973 2 3
5 13 72.28 17 15.02 403 2 3
6 8 0.08 175 15.00 286 2 4

Cycle 141 GMT 11/ 9/2023 8:38: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 30 14.96 455 2 3
2 7 2006.96 52 14.85 3090 2 2
3 13 1019.84 17 14.82 1747 2 3
4 13 441.08 17 14.94 949 2 3
5 13 68.04 17 15.02 393 2 3
6 8 0.04 175 15.00 283 2 3

Cycle 140 GMT 1/ 9/2023 11:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 30 14.94 452 2 3
2 7 2005.28 53 14.84 3082 2 2
3 13 1027.72 17 14.82 1770 2 3
4 13 445.36 17 14.93 959 2 3
5 13 65.44 17 15.03 393 2 3
6 8 0.04 175 15.00 286 2 5
7 14 0.04 20 14.99 288 2 6

Cycle 139 GMT 22/ 8/2023 13:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 30 14.94 481 2 3
2 7 2003.28 53 14.84 3066 2 2
3 13 1006.32 17 14.82 1736 2 3
4 13 427.00 17 14.93 934 2 3
5 13 55.88 17 15.03 375 2 2
6 8 0.12 175 15.00 284 2 3

Cycle 138 GMT 12/ 8/2023 16:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 14.95 458 2 3
2 7 2012.12 54 14.84 3092 2 2
3 13 909.60 17 14.84 1610 2 3
4 13 478.84 17 14.92 1003 2 3
5 13 74.40 17 15.02 409 2 3
6 8 -0.12 175 15.00 289 2 7

Cycle 137 GMT 2/ 8/2023 19: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 30 14.95 476 2 3
2 7 2009.28 52 14.85 3077 2 3
3 13 1016.96 17 14.82 1752 2 3
4 13 451.72 17 14.94 968 2 3
5 13 68.72 17 15.03 400 2 3
6 8 0.20 175 15.00 289 2 4
7 14 0.20 20 14.98 287 2 5

Cycle 136 GMT 23/ 7/2023 21:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 30 14.94 481 2 3
2 7 2003.80 53 14.86 3077 2 3
3 13 1020.92 17 14.81 1752 2 3
4 13 577.48 17 14.90 1141 2 3
5 13 55.36 17 15.03 382 2 3
6 8 -0.04 175 15.00 291 2 3

Cycle 135 GMT 14/ 7/2023 0:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 30 14.95 465 2 3
2 7 2002.80 53 14.86 3080 2 2
3 13 1025.40 17 14.82 1761 2 3
4 13 453.80 17 14.94 969 2 3
5 13 71.80 17 15.03 408 2 4
6 8 0.08 175 15.00 295 2 2

Cycle 134 GMT 4/ 7/2023 2:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 30 14.95 473 2 3
2 7 2004.00 53 14.85 3055 2 2
3 13 1019.68 17 14.82 1745 2 3
4 13 448.16 17 14.93 960 2 3
5 13 69.04 17 15.03 401 2 3
6 8 0.24 175 15.01 288 2 6

Cycle 133 GMT 24/ 6/2023 5:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 14.94 449 2 3
2 7 2003.12 53 14.85 3060 2 2
3 13 1023.28 17 14.81 1759 2 3
4 13 457.48 17 14.93 975 2 3
5 13 71.84 17 15.03 404 2 4
6 8 -0.12 175 15.00 287 2 6

Cycle 132 GMT 14/ 6/2023 7:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 14.96 469 2 3
2 7 2004.00 53 14.86 3075 2 2
3 13 1016.60 17 14.83 1745 2 3
4 13 452.60 17 14.94 966 2 3
5 13 75.28 17 15.02 408 2 2
6 8 0.20 175 15.01 287 2 3

Cycle 131 GMT 4/ 6/2023 10:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 14.95 440 2 3
2 7 2004.60 52 14.85 3062 2 2
3 13 1018.16 17 14.82 1748 2 3
4 13 572.24 17 14.89 1129 2 3
5 13 61.72 17 15.03 389 2 3
6 8 -0.08 175 15.00 287 2 3
7 14 -0.08 20 14.98 288 2 3

Cycle 130 GMT 25/ 5/2023 12:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 30 14.95 447 3 3
2 7 2002.60 53 14.85 3052 2 2
3 13 1020.36 17 14.82 1744 2 3
4 13 448.68 17 14.94 966 2 3
5 13 71.96 17 15.03 406 2 3
6 8 0.00 175 15.00 288 2 3

Cycle 129 GMT 15/ 5/2023 15:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 14.95 441 2 3
2 7 2002.88 52 14.85 3055 2 2
3 13 1011.28 17 14.82 1733 2 3
4 13 448.24 17 14.94 957 2 3
5 13 74.04 17 15.03 405 2 3
6 8 0.04 175 15.00 282 2 2

Cycle 128 GMT 5/ 5/2023 18: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 30 14.93 458 2 3
2 7 2008.88 53 14.86 3074 2 2
3 13 1020.28 17 14.83 1747 2 4
4 13 450.28 17 14.93 964 2 3
5 13 68.28 17 15.03 403 2 3
6 8 0.12 175 15.01 285 2 3

Cycle 127 GMT 25/ 4/2023 20:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 30 14.95 443 3 3
2 7 2005.28 53 14.83 3057 2 2
3 13 1030.52 17 14.81 1765 2 3
4 13 585.64 17 14.90 1152 2 3
5 13 61.00 17 15.02 386 2 3
6 8 -0.28 175 14.99 290 2 3

Cycle 126 GMT 15/ 4/2023 23:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 30 14.95 469 2 3
2 7 2004.44 52 14.86 3063 2 2
3 13 1024.92 17 14.83 1760 2 3
4 13 454.96 17 14.94 971 2 3
5 13 73.36 17 15.03 406 2 3
6 8 0.28 175 15.01 286 2 3

Cycle 125 GMT 6/ 4/2023 1:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 30 14.95 438 2 3
2 7 2004.80 53 14.84 3067 2 2
3 13 898.44 17 14.85 1581 2 3
4 13 343.24 17 14.97 810 2 3
5 13 50.00 17 15.04 371 2 2
6 8 0.04 175 15.00 285 2 3

Cycle 124 GMT 27/ 3/2023 4:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 14.96 439 3 3
2 7 2004.28 53 14.86 3074 2 2
3 13 1017.16 17 14.83 1752 2 3
4 13 445.88 17 14.94 953 2 3
5 13 68.76 17 15.04 397 2 3
6 8 -0.08 175 15.01 282 2 6

Cycle 123 GMT 17/ 3/2023 7: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 30 14.95 435 2 3
2 7 2004.96 52 14.86 3074 2 2
3 13 1025.64 17 14.82 1754 2 3
4 13 448.24 17 14.94 958 2 3
5 13 66.28 17 15.04 395 2 3
6 8 0.08 175 15.01 285 2 3
7 14 0.08 20 14.99 283 2 10

Cycle 122 GMT 7/ 3/2023 9:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 30 14.94 438 3 3
2 7 2004.48 53 14.85 3056 2 2
3 13 1021.84 17 14.82 1754 2 3
4 13 445.24 17 14.94 953 2 3
5 13 64.28 17 15.04 389 2 3
6 8 -0.12 175 15.00 281 2 4

Cycle 121 GMT 25/ 2/2023 12: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 14.96 444 2 3
2 7 2003.68 53 14.85 3060 2 2
3 13 1018.92 17 14.82 1748 2 3
4 13 448.88 17 14.94 957 2 3
5 13 66.32 17 15.03 394 2 3
6 8 -0.04 175 15.00 284 2 3

Cycle 120 GMT 15/ 2/2023 14:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 30 14.95 440 2 3
2 7 2004.40 53 14.85 3069 2 3
3 13 1014.16 17 14.82 1744 2 3
4 13 435.88 17 14.95 942 2 3
5 13 64.88 17 15.04 391 2 3
6 8 0.16 175 15.00 284 2 3

Cycle 119 GMT 5/ 2/2023 17:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 30 14.96 443 3 3
2 7 2004.64 53 14.86 3056 2 2
3 13 1013.92 17 14.83 1739 2 3
4 13 436.56 17 14.95 941 2 3
5 13 62.12 17 15.04 388 2 3
6 8 0.08 175 15.01 283 2 5

Cycle 118 GMT 26/ 1/2023 20: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 30 14.96 447 2 3
2 7 2002.96 52 14.87 3073 2 3
3 13 1027.48 17 14.84 1761 2 3
4 13 453.28 17 14.95 968 2 3
5 13 65.92 17 15.04 397 2 3
6 8 0.16 175 15.01 290 2 7

Cycle 117 GMT 16/ 1/2023 22:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 30 14.96 447 3 3
2 7 2003.84 52 14.86 3061 2 2
3 13 1028.20 17 14.83 1763 2 3
4 13 447.40 17 14.94 953 2 3
5 13 65.52 17 15.04 395 2 3
6 8 0.24 175 15.01 287 2 4

Cycle 116 GMT 7/ 1/2023 1:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 14.97 446 3 3
2 7 2008.80 52 14.86 3059 2 2
3 13 1028.16 17 14.84 1758 2 3
4 13 449.36 17 14.95 957 2 3
5 13 65.20 17 15.05 390 2 3
6 8 -0.24 175 15.01 285 2 4

Cycle 115 GMT 28/12/2022 3:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 14.97 469 3 3
2 7 2003.28 53 14.86 3053 2 2
3 13 1021.48 17 14.84 1751 2 3
4 13 444.52 17 14.96 954 2 3
5 13 64.92 17 15.05 390 2 3
6 8 0.36 175 15.02 286 2 4

Cycle 114 GMT 18/12/2022 6:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 30 14.96 476 2 3
2 7 2004.64 52 14.87 3073 2 2
3 13 1021.32 17 14.84 1756 2 3
4 13 452.20 17 14.96 966 2 3
5 13 66.92 17 15.04 403 2 3
6 8 0.04 175 15.03 288 2 6

Cycle 113 GMT 8/12/2022 9: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 30 14.96 453 2 3
2 7 2004.44 53 14.85 3062 2 2
3 13 1026.92 17 14.83 1765 2 3
4 13 453.72 17 14.94 969 2 3
5 13 67.84 17 15.03 402 2 3
6 8 0.04 175 15.01 288 2 6

Cycle 112 GMT 28/11/2022 11:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 14.97 452 2 3
2 7 2014.08 53 14.86 3075 2 2
3 13 1030.32 17 14.83 1766 2 3
4 13 454.60 17 14.95 965 2 3
5 13 69.04 17 15.05 404 2 3
6 8 0.08 175 15.02 291 2 6

Cycle 111 GMT 18/11/2022 14:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 30 14.97 484 2 3
2 7 2003.08 53 14.88 3069 2 3
3 13 1019.92 17 14.85 1753 2 3
4 13 452.72 17 14.95 968 2 3
5 13 71.00 17 15.05 406 2 3
6 8 0.08 175 15.02 290 2 3

Cycle 110 GMT 8/11/2022 16:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 30 14.97 478 2 3
2 7 2011.08 53 14.87 3066 2 2
3 13 1026.92 17 14.85 1751 2 3
4 13 452.00 17 14.96 960 2 3
5 13 70.12 17 15.05 410 2 3
6 8 -0.08 175 15.03 290 2 4

Cycle 109 GMT 29/10/2022 19:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 14.97 452 2 3
2 7 2010.00 53 14.87 3070 2 2
3 13 1031.92 17 14.84 1769 2 4
4 13 457.72 17 14.95 971 2 3
5 13 69.32 17 15.05 403 2 3
6 8 0.16 175 15.02 292 2 3

Cycle 108 GMT 19/10/2022 22: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 30 14.97 475 2 3
2 7 2003.24 53 14.88 3065 2 2
3 13 1025.60 17 14.85 1762 2 3
4 13 454.84 17 14.96 967 2 3
5 13 70.20 17 15.05 401 2 3
6 8 0.16 175 15.03 290 2 4

Cycle 107 GMT 10/10/2022 0:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 30 14.97 474 2 3
2 7 2004.56 52 14.87 3063 2 2
3 13 1027.08 17 14.85 1765 2 3
4 13 448.72 17 14.96 957 2 3
5 13 66.36 17 15.06 396 2 3
6 8 -0.04 175 15.02 287 2 5

Cycle 106 GMT 30/ 9/2022 3:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 30 14.97 480 2 3
2 7 2011.88 53 14.87 3072 2 2
3 13 1023.92 17 14.84 1762 2 3
4 13 448.32 17 14.96 958 2 3
5 13 64.20 17 15.05 397 2 3
6 8 0.08 175 15.03 292 2 3

Cycle 105 GMT 20/ 9/2022 5:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 14.97 458 2 3
2 7 2005.04 53 14.87 3067 2 2
3 13 1016.12 17 14.84 1741 2 3
4 13 440.72 17 14.97 951 2 3
5 13 62.96 17 15.05 393 2 3
6 8 0.32 175 15.03 289 2 4

Cycle 104 GMT 10/ 9/2022 8:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 30 14.98 481 2 3
2 7 2009.80 53 14.87 3082 2 2
3 13 1025.64 17 14.84 1760 2 3
4 13 442.88 17 14.97 964 2 3
5 13 65.32 17 15.06 394 2 3
6 8 0.00 175 15.04 292 2 3

Cycle 103 GMT 31/ 8/2022 10:56: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 30 14.99 450 2 3
2 7 2011.00 53 14.88 3075 2 3
3 13 1029.56 17 14.85 1771 2 3
4 13 454.20 17 14.97 969 2 3
5 13 63.60 17 15.07 394 2 3
6 8 0.08 175 15.03 295 2 3

Cycle 102 GMT 21/ 8/2022 13:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 30 14.98 473 2 3
2 7 2003.60 53 14.88 3072 2 3
3 13 1009.76 17 14.86 1746 2 3
4 13 430.20 17 14.97 937 2 3
5 13 60.96 17 15.06 390 2 3
6 8 0.16 175 15.04 291 2 3

Cycle 101 GMT 11/ 8/2022 15:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 30 14.98 484 2 3
2 7 2005.36 53 14.87 3058 2 2
3 13 1026.80 17 14.85 1756 2 3
4 13 445.00 17 14.98 953 2 3
5 13 65.40 17 15.06 387 2 4
6 8 -0.08 175 15.04 285 2 3
7 14 -0.08 20 15.02 284 2 3

Cycle 100 GMT 1/ 8/2022 18:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 30 14.99 452 2 3
2 7 2003.08 53 14.87 3059 2 3
3 13 1019.20 17 14.86 1759 2 3
4 13 459.52 17 14.98 979 2 3
5 13 70.96 17 15.07 405 2 3
6 8 0.12 175 15.04 288 2 5

Cycle 99 GMT 22/ 7/2022 21: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 30 14.99 450 3 3
2 7 2003.52 53 14.88 3063 2 3
3 13 1026.80 17 14.86 1763 2 3
4 13 450.36 17 14.97 967 2 3
5 13 69.52 17 15.07 398 2 3
6 8 -0.16 175 15.04 287 2 6

Cycle 98 GMT 12/ 7/2022 23:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 14.99 472 2 3
2 7 2009.32 52 14.87 3083 2 2
3 13 1014.40 17 14.85 1748 2 3
4 13 441.48 17 14.98 954 2 3
5 13 68.40 17 15.07 397 2 3
6 8 0.24 175 15.05 288 2 4

Cycle 97 GMT 3/ 7/2022 2: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 30 14.99 470 2 3
2 7 2003.24 53 14.88 3081 2 3
3 13 1023.60 17 14.86 1771 2 3
4 13 452.32 17 14.98 970 2 3
5 13 69.12 17 15.08 401 2 3
6 8 0.00 175 15.05 290 2 4

Cycle 96 GMT 23/ 6/2022 4:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 30 14.99 474 2 3
2 7 2002.56 53 14.88 3072 2 3
3 13 1021.92 17 14.86 1760 2 3
4 13 447.88 17 14.98 959 2 3
5 13 69.36 17 15.08 401 2 3
6 8 0.20 175 15.05 287 2 3

Cycle 95 GMT 13/ 6/2022 7: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 30 14.99 465 3 3
2 7 2009.32 52 14.87 3089 2 2
3 13 1011.48 17 14.86 1738 2 3
4 13 436.56 17 14.98 944 2 3
5 13 65.52 17 15.07 397 2 3
6 8 0.20 175 15.05 284 2 4

Cycle 94 GMT 3/ 6/2022 9:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 14.99 447 3 3
2 7 2009.76 53 14.87 3079 2 3
3 13 1024.64 17 14.85 1762 2 3
4 13 441.56 17 14.98 955 2 3
5 13 65.16 17 15.07 390 2 3
6 8 0.00 175 15.04 285 2 4

Cycle 93 GMT 24/ 5/2022 12: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 30 14.99 466 3 3
2 7 2003.40 53 14.88 3070 2 3
3 13 911.08 17 14.88 1610 2 3
4 13 481.84 17 14.98 1012 2 3
5 13 75.92 17 15.08 408 2 3
6 8 0.00 175 15.05 281 2 3

Cycle 92 GMT 14/ 5/2022 14:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 30 15.00 472 2 3
2 7 2003.68 53 14.88 3079 2 3
3 13 1014.88 17 14.86 1744 2 3
4 13 439.04 17 14.98 949 2 3
5 13 64.00 17 15.09 395 2 3
6 8 0.12 175 15.05 288 2 4

Cycle 91 GMT 4/ 5/2022 17: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 30 14.99 469 3 3
2 7 2003.68 53 14.87 3062 2 3
3 13 1007.76 17 14.86 1741 2 3
4 13 426.20 17 14.99 934 2 3
5 13 64.84 17 15.08 395 2 3
6 8 0.04 175 15.05 288 2 3

Cycle 90 GMT 24/ 4/2022 19:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.68 30 15.00 474 3 3
2 7 2008.16 53 14.89 3073 2 3
3 13 1022.88 17 14.87 1758 2 3
4 13 449.28 17 14.99 960 2 3
5 13 94.16 17 15.07 444 2 3
6 13 27.80 17 15.08 329 2 3
7 8 0.04 175 15.05 287 2 4

Cycle 89 GMT 14/ 4/2022 21:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 15.00 438 3 3
2 7 2004.40 53 14.90 3067 2 3
3 13 1013.04 17 14.87 1737 2 3
4 13 438.40 17 14.98 946 2 3
5 13 62.72 17 15.09 393 2 3
6 8 0.00 175 15.06 289 2 3

Cycle 88 GMT 5/ 4/2022 0:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 15.00 444 3 3
2 7 2003.04 53 14.89 3066 2 2
3 13 1009.12 17 14.87 1732 2 3
4 13 437.72 17 14.99 949 2 3
5 13 63.48 17 15.08 389 2 3
6 8 0.08 175 15.06 286 2 3

Cycle 87 GMT 26/ 3/2022 3: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 30 14.99 445 3 3
2 7 2004.08 53 14.90 3069 2 2
3 13 910.56 17 14.91 1607 2 3
4 13 480.04 17 14.99 1003 2 3
5 13 72.60 17 15.08 404 2 3
6 8 0.00 175 15.06 286 2 3

Cycle 86 GMT 16/ 3/2022 5:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 15.01 439 2 3
2 7 2009.20 53 14.89 3074 2 3
3 13 1017.40 17 14.87 1748 2 3
4 13 444.16 17 14.99 952 2 3
5 13 70.32 17 15.08 398 2 3
6 8 0.00 175 15.06 286 2 3

Cycle 85 GMT 6/ 3/2022 7:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.56 30 15.00 469 2 3
2 7 2004.16 53 14.90 3066 2 3
3 13 1012.56 17 14.87 1735 2 3
4 13 438.16 17 15.00 944 2 3
5 13 60.96 17 15.09 383 2 3
6 8 0.16 175 15.06 285 2 3

Cycle 84 GMT 24/ 2/2022 10:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 30 15.02 446 3 3
2 7 2002.72 52 14.89 3051 2 2
3 13 1015.88 17 14.87 1746 2 3
4 13 446.84 17 15.00 959 2 3
5 13 66.04 17 15.08 390 2 3
6 8 0.00 175 15.06 290 2 4

Cycle 83 GMT 14/ 2/2022 13: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 15.02 438 3 3
2 7 2003.04 52 14.90 3067 2 2
3 13 1014.12 17 14.88 1742 2 3
4 13 434.68 17 15.00 935 2 3
5 13 60.24 17 15.10 387 2 3
6 8 -0.04 175 15.07 287 2 3

Cycle 82 GMT 4/ 2/2022 15:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 15.02 437 3 3
2 7 2005.72 53 14.90 3066 2 3
3 13 1028.08 17 14.88 1754 2 3
4 13 454.48 17 15.00 972 2 3
5 13 40.48 17 15.10 350 2 3
6 8 0.24 175 15.07 287 2 5

Cycle 81 GMT 25/ 1/2022 18: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 30 15.03 442 3 3
2 7 2011.16 53 14.90 3071 2 3
3 13 1034.12 17 14.89 1774 2 3
4 13 457.44 17 15.01 974 2 3
5 13 72.60 17 15.10 407 2 3
6 8 -0.08 175 15.07 287 2 4

Cycle 80 GMT 15/ 1/2022 20:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 15.02 447 3 3
2 7 2004.12 53 14.90 3056 2 2
3 13 914.72 17 14.92 1611 2 3
4 13 486.72 17 15.00 1014 2 3
5 13 79.24 17 15.10 416 2 3
6 8 0.16 175 15.08 287 2 3

Cycle 79 GMT 5/ 1/2022 23:10: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 30 15.03 466 3 3
2 7 2007.88 53 14.89 3057 2 2
3 13 1026.92 17 14.88 1765 2 3
4 13 462.12 17 15.00 983 2 3
5 13 38.00 17 15.11 350 2 2
6 8 0.12 175 15.08 285 2 3

Cycle 78 GMT 27/12/2021 1:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 30 15.03 474 2 3
2 7 2003.64 53 14.91 3062 2 3
3 13 1014.68 17 14.90 1741 2 3
4 13 436.84 17 15.03 950 2 3
5 13 62.92 17 15.12 390 2 3
6 8 0.00 175 15.09 287 2 3

Cycle 77 GMT 17/12/2021 4:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.44 30 15.03 474 2 3
2 7 2004.08 53 14.91 3066 2 3
3 13 1016.88 17 14.90 1741 2 3
4 13 445.28 17 15.02 959 2 3
5 13 66.28 17 15.11 393 2 3
6 8 0.20 175 15.09 287 2 4

Cycle 76 GMT 7/12/2021 6:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 15.03 466 2 3
2 7 2003.40 53 14.92 3076 2 3
3 13 1022.12 17 14.90 1754 2 3
4 13 445.76 17 15.03 954 2 3
5 13 65.64 17 15.12 392 2 3
6 8 -0.04 175 15.09 286 2 5

Cycle 75 GMT 27/11/2021 9:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 30 15.04 475 2 3
2 7 2010.32 53 14.91 3075 2 2
3 13 1013.92 17 14.91 1744 2 3
4 13 567.96 17 15.00 1132 2 3
5 13 55.24 17 15.12 373 2 3
6 8 0.00 175 15.10 286 2 5

Cycle 74 GMT 17/11/2021 11:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 30 15.05 476 3 3
2 7 2005.20 53 14.90 3069 2 3
3 13 1024.20 17 14.90 1755 2 3
4 13 442.12 17 15.02 954 2 4
5 13 63.20 17 15.13 389 2 3
6 8 0.16 175 15.10 289 2 3

Cycle 73 GMT 7/11/2021 14:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 30 15.05 477 2 3
2 7 2011.24 54 14.90 3081 2 2
3 13 1015.48 17 14.90 1744 2 3
4 13 427.04 17 15.04 933 2 3
5 13 56.88 17 15.13 380 2 3
6 8 0.16 175 15.10 289 2 5

Cycle 72 GMT 28/10/2021 17: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 30 15.05 475 2 3
2 7 2012.20 53 14.93 3089 2 3
3 13 1017.36 17 14.91 1758 2 3
4 13 443.12 17 15.04 956 2 3
5 13 64.44 17 15.14 395 2 3
6 8 -0.04 175 15.10 288 2 5

Cycle 71 GMT 18/10/2021 19:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 30 15.06 479 3 3
2 7 2010.52 53 14.93 3072 2 3
3 13 1009.92 17 14.92 1744 2 3
4 13 423.56 17 15.05 928 2 3
5 13 56.08 17 15.15 379 2 3
6 8 0.00 175 15.11 290 2 4

Cycle 70 GMT 8/10/2021 21:59: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 30 15.05 474 2 3
2 7 2004.88 52 14.93 3079 2 3
3 13 1012.92 17 14.92 1747 2 3
4 13 429.12 17 15.05 940 2 3
5 13 58.00 17 15.15 386 2 3
6 8 0.16 175 15.11 293 2 3

Cycle 69 GMT 29/ 9/2021 0:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 30 15.06 479 2 3
2 7 2010.72 53 14.92 3069 2 3
3 13 1011.04 17 14.93 1749 2 3
4 13 435.32 17 15.05 946 2 3
5 13 29.32 17 15.15 344 2 3
6 8 0.00 175 15.12 292 2 2

Cycle 68 GMT 19/ 9/2021 3: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.60 30 15.07 485 3 3
2 7 2010.88 52 14.92 3086 2 2
3 13 1028.96 17 14.92 1764 2 3
4 13 450.44 17 15.05 967 2 3
5 13 67.12 17 15.15 402 2 3
6 8 0.08 175 15.12 288 2 3

Cycle 67 GMT 9/ 9/2021 5:34: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 29 15.07 471 2 3
2 7 2003.32 53 14.92 3072 2 3
3 13 1003.04 17 14.93 1733 2 3
4 13 429.16 17 15.06 933 2 3
5 13 59.00 17 15.15 387 2 3
6 8 0.08 175 15.12 290 2 3

Cycle 66 GMT 30/ 8/2021 8:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 29 15.09 475 2 3
2 7 2005.96 52 14.93 3072 2 3
3 13 1025.00 17 14.93 1763 2 3
4 13 444.56 17 15.06 958 2 3
5 13 65.56 17 15.15 398 2 3
6 8 0.48 175 15.13 287 2 4

Cycle 65 GMT 20/ 8/2021 10:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 29 15.09 484 2 3
2 7 2009.00 53 14.94 3079 2 3
3 13 1015.76 17 14.94 1750 2 3
4 13 435.28 17 15.07 944 2 3
5 13 31.92 17 15.17 342 2 3
6 8 -0.36 175 15.13 290 2 4
7 14 -0.36 20 15.11 293 2 6

Cycle 64 GMT 10/ 8/2021 13: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 29 15.08 483 2 3
2 7 2003.76 53 14.95 3061 2 3
3 13 1012.84 17 14.95 1745 2 3
4 13 433.40 17 15.08 950 2 3
5 13 60.52 17 15.17 393 2 3
6 8 0.12 175 15.14 293 2 4

Cycle 63 GMT 31/ 7/2021 15:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 29 15.08 482 2 3
2 7 2009.44 53 14.93 3067 2 3
3 13 1025.84 17 14.94 1751 2 3
4 13 444.96 17 15.07 960 2 3
5 13 62.04 17 15.16 393 2 4
6 8 0.08 175 15.13 291 2 3

Cycle 62 GMT 21/ 7/2021 18:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 29 15.09 485 2 3
2 7 2004.04 53 14.94 3059 2 2
3 13 1020.36 17 14.94 1753 2 3
4 13 442.24 17 15.08 956 2 3
5 13 65.76 17 15.16 399 2 3
6 8 0.00 175 15.14 292 2 3

Cycle 61 GMT 11/ 7/2021 20:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 29 15.09 459 2 3
2 7 2002.96 53 14.94 3059 2 3
3 13 1018.88 17 14.94 1753 2 3
4 13 429.88 17 15.08 937 2 3
5 13 57.88 17 15.17 394 2 3
6 8 0.00 175 15.14 299 2 4

Cycle 60 GMT 1/ 7/2021 23: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 29 15.09 483 2 3
2 7 2010.32 52 14.94 3082 2 3
3 13 1023.28 17 14.95 1757 2 3
4 13 450.40 17 15.08 971 2 3
5 13 62.28 17 15.18 399 2 3
6 8 0.24 175 15.15 297 2 3
7 14 0.24 20 15.13 296 2 4

Cycle 59 GMT 22/ 6/2021 1:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 29 15.10 479 2 3
2 7 2004.48 53 14.95 3072 2 2
3 13 1005.52 17 14.95 1733 2 3
4 13 433.16 17 15.09 942 2 3
5 13 63.04 17 15.18 398 2 3
6 8 -0.04 175 15.15 297 2 3
7 14 -0.04 20 15.14 294 2 3

Cycle 58 GMT 12/ 6/2021 4: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 29 15.10 478 3 3
2 7 2009.00 52 14.94 3076 2 3
3 13 1011.76 17 14.96 1748 2 4
4 13 442.40 17 15.10 959 2 3
5 13 62.76 17 15.19 398 2 3
6 8 0.12 175 15.16 293 2 3

Cycle 57 GMT 2/ 6/2021 6:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 29 15.12 450 2 3
2 7 2007.64 52 14.95 3070 2 3
3 13 890.24 17 15.00 1575 2 3
4 13 338.12 17 15.13 816 2 3
5 13 50.64 17 15.20 383 2 3
6 8 -0.04 175 15.16 296 2 4

Cycle 56 GMT 23/ 5/2021 8:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 15.11 466 3 3
2 7 2011.88 53 14.96 3078 2 3
3 13 1003.36 17 14.98 1727 2 3
4 13 437.52 17 15.11 947 2 3
5 13 60.44 17 15.20 394 2 3
6 8 0.16 175 15.18 295 2 5

Cycle 55 GMT 13/ 5/2021 11:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 29 15.12 487 3 3
2 7 2011.28 53 14.95 3071 2 3
3 13 1023.60 17 14.98 1764 2 3
4 13 441.36 17 15.11 956 2 3
5 13 64.04 17 15.20 405 2 3
6 8 0.00 175 15.18 302 2 4
7 14 0.00 20 15.15 299 2 9

Cycle 54 GMT 3/ 5/2021 13:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 29 15.13 488 2 3
2 7 2010.64 53 14.97 3084 2 3
3 13 1013.64 17 14.98 1743 2 4
4 13 440.84 17 15.13 953 2 3
5 13 61.92 17 15.21 399 2 3
6 8 0.12 175 15.18 298 2 4

Cycle 53 GMT 23/ 4/2021 16:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 29 15.14 491 3 3
2 7 2007.68 53 14.97 3085 2 3
3 13 1017.72 17 14.98 1754 2 3
4 13 429.16 17 15.12 942 2 3
5 13 57.40 17 15.22 396 2 3
6 8 0.04 175 15.18 303 2 4

Cycle 52 GMT 13/ 4/2021 18:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 29 15.14 478 3 3
2 7 2002.48 52 14.97 3067 2 3
3 13 1028.84 17 14.99 1776 2 3
4 13 451.84 17 15.13 966 2 3
5 13 66.00 17 15.22 406 2 3
6 8 0.08 175 15.19 301 2 3

Cycle 51 GMT 3/ 4/2021 21:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 29 15.15 458 3 3
2 7 2006.16 53 14.96 3062 2 2
3 13 1009.88 17 15.00 1736 2 3
4 13 443.40 17 15.13 958 2 3
5 13 58.12 17 15.23 392 2 3
6 8 -0.12 175 15.20 299 2 4

Cycle 50 GMT 24/ 3/2021 23:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 29 15.14 473 3 3
2 7 2006.08 53 14.96 3059 2 3
3 13 1005.36 17 15.00 1737 2 3
4 13 423.72 17 15.14 936 2 3
5 13 55.16 17 15.22 387 2 3
6 8 0.04 175 15.20 297 2 6

Cycle 49 GMT 15/ 3/2021 2: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 29 15.14 476 3 3
2 7 2008.64 53 14.98 3076 2 3
3 13 1007.12 17 15.01 1739 2 3
4 13 432.28 17 15.14 943 2 3
5 13 53.28 17 15.23 381 2 3
6 8 0.24 175 15.21 294 2 3

Cycle 48 GMT 5/ 3/2021 4:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 29 15.15 483 2 3
2 7 2002.64 53 14.97 3065 2 3
3 13 1010.88 17 15.01 1748 2 3
4 13 429.28 17 15.14 942 2 3
5 13 55.32 17 15.24 388 2 3
6 8 -0.08 175 15.20 298 2 5

Cycle 47 GMT 23/ 2/2021 7: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 15.15 451 3 3
2 7 2004.52 53 14.96 3062 2 3
3 13 1008.72 17 15.00 1739 2 3
4 13 302.52 17 15.18 760 2 3
5 13 36.32 17 15.24 362 2 3
6 8 0.16 175 15.20 302 2 3

Cycle 46 GMT 13/ 2/2021 9:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 29 15.16 478 2 3
2 7 2009.08 53 14.99 3077 2 3
3 13 1012.04 17 15.01 1743 2 3
4 13 432.88 17 15.15 946 2 3
5 13 57.40 17 15.24 394 2 3
6 8 0.12 175 15.21 301 2 6

Cycle 45 GMT 3/ 2/2021 11:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 29 15.16 487 3 3
2 7 2007.80 53 14.97 3076 2 3
3 13 1008.08 17 15.01 1742 2 3
4 13 433.32 17 15.15 947 2 3
5 13 56.60 17 15.24 391 2 3
6 8 0.04 175 15.21 302 2 4

Cycle 44 GMT 24/ 1/2021 14:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 29 15.15 488 3 3
2 7 2007.20 53 14.97 3077 2 3
3 13 1019.64 17 15.01 1757 2 3
4 13 429.16 17 15.15 940 2 3
5 13 56.72 17 15.24 391 2 3
6 8 0.00 175 15.21 302 2 4

Cycle 43 GMT 14/ 1/2021 16:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.92 29 15.16 488 2 3
2 7 2010.76 53 14.98 3073 2 3
3 13 1018.72 17 15.01 1755 2 3
4 13 441.72 17 15.15 960 2 3
5 13 59.76 17 15.25 392 2 3
6 8 0.08 175 15.22 298 2 4

Cycle 42 GMT 4/ 1/2021 19:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 29 15.16 485 2 3
2 7 2008.60 53 14.98 3077 2 3
3 13 1024.36 17 15.02 1767 2 3
4 13 437.56 17 15.16 954 2 3
5 13 58.76 17 15.25 389 2 2
6 8 0.24 175 15.22 297 2 3

Cycle 41 GMT 25/12/2020 21:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 29 15.17 459 2 3
2 7 2008.76 52 14.99 3086 2 3
3 13 1021.04 17 15.02 1759 2 3
4 13 318.12 17 15.19 785 2 3
5 13 41.68 17 15.26 365 2 2
6 8 -0.04 175 15.22 297 2 3

Cycle 40 GMT 16/12/2020 0:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 15.17 487 2 3
2 7 2008.84 53 14.98 3078 2 3
3 13 1000.44 17 15.03 1726 2 3
4 13 421.24 17 15.17 929 2 3
5 13 54.36 17 15.25 383 2 2
6 8 0.16 175 15.22 298 2 5

Cycle 39 GMT 6/12/2020 2:41: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 29 15.17 487 2 3
2 7 2011.04 52 14.99 3071 2 2
3 13 1006.80 17 15.03 1741 2 4
4 13 420.96 17 15.18 935 2 3
5 13 52.32 17 15.25 385 2 3
6 8 -0.08 175 15.23 306 2 3

Cycle 38 GMT 26/11/2020 5:14: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 29 15.18 485 2 3
2 7 2002.64 53 14.99 3066 2 3
3 13 1013.92 17 15.03 1746 2 3
4 13 433.00 17 15.16 949 2 3
5 13 58.28 17 15.25 389 2 3
6 8 0.08 175 15.23 298 2 3

Cycle 37 GMT 16/11/2020 7:48:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 29 15.17 492 2 3
2 7 2009.00 53 14.99 3076 2 3
3 13 990.24 17 15.04 1714 2 4
4 13 412.00 17 15.17 921 2 3
5 13 53.92 17 15.26 386 2 3
6 8 0.16 175 15.24 300 2 3

Cycle 36 GMT 6/11/2020 10:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 29 15.19 490 2 3
2 7 2004.16 53 14.99 3066 2 2
3 13 1008.68 17 15.04 1738 2 3
4 13 423.68 17 15.17 938 2 3
5 13 26.64 17 15.27 342 2 2
6 8 0.08 175 15.23 302 2 3

Cycle 35 GMT 27/10/2020 12:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 29 15.18 484 2 3
2 7 2009.16 53 15.00 3080 2 3
3 13 999.60 17 15.03 1732 2 3
4 13 422.24 17 15.17 933 2 3
5 8 0.44 175 15.24 300 2 3

Cycle 34 GMT 17/10/2020 15:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 29 15.20 493 2 3
2 7 2009.60 53 14.99 3069 2 3
3 13 1001.72 17 15.04 1741 2 3
4 13 416.20 17 15.18 932 2 3
5 13 50.60 17 15.28 378 2 2
6 8 -0.12 175 15.25 299 2 3

Cycle 33 GMT 7/10/2020 17:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 29 15.20 498 2 3
2 7 2007.92 53 15.00 3078 2 3
3 13 1004.92 17 15.05 1742 2 3
4 13 405.68 17 15.19 912 2 3
5 13 50.96 17 15.28 373 2 3
6 8 0.12 175 15.25 299 2 3

Cycle 32 GMT 27/ 9/2020 20:21: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 29 15.20 494 2 3
2 7 2005.00 53 15.00 3070 2 3
3 13 1003.60 17 15.05 1741 2 3
4 13 419.44 17 15.18 928 2 3
5 8 0.00 175 15.26 304 2 3

Cycle 31 GMT 17/ 9/2020 22:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 29 15.20 494 2 3
2 7 2010.96 53 15.00 3078 2 2
3 13 1012.00 17 15.05 1751 2 3
4 13 314.28 17 15.22 779 2 3
5 8 0.24 175 15.26 303 2 3

Cycle 30 GMT 8/ 9/2020 1: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 29 15.21 496 2 3
2 7 2009.60 53 15.01 3079 2 3
3 13 1007.76 17 15.05 1741 2 3
4 13 412.52 17 15.20 924 2 3
5 13 24.96 17 15.29 342 2 3
6 8 -0.24 175 15.25 306 2 2

Cycle 29 GMT 29/ 8/2020 3:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 29 15.21 498 2 3
2 7 2010.60 53 15.01 3080 2 3
3 13 1003.84 17 15.06 1744 2 3
4 13 416.92 17 15.21 934 2 3
5 8 0.04 175 15.27 304 2 3

Cycle 28 GMT 19/ 8/2020 6: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 29 15.21 495 2 3
2 7 2008.04 52 15.01 3084 2 2
3 13 1008.44 17 15.07 1751 2 3
4 13 412.72 17 15.20 931 2 3
5 13 51.48 17 15.29 385 2 2
6 8 0.16 175 15.26 302 2 3

Cycle 27 GMT 9/ 8/2020 8:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 28 15.21 480 2 3
2 7 2006.12 53 15.01 3076 2 2
3 13 997.64 17 15.05 1728 2 3
4 13 412.80 17 15.20 924 2 3
5 13 26.16 17 15.29 340 2 3
6 8 0.40 175 15.26 302 2 3

Cycle 26 GMT 30/ 7/2020 11:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 15.22 488 2 3
2 7 2002.60 53 15.02 3067 2 3
3 13 1003.16 17 15.07 1732 2 3
4 13 412.68 17 15.20 917 2 3
5 8 1.00 175 15.27 297 2 4
6 14 1.00 20 15.25 299 2 3

Cycle 25 GMT 20/ 7/2020 13:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 28 15.22 489 2 3
2 7 2008.64 53 15.02 3081 2 2
3 13 893.60 17 15.09 1588 2 3
4 13 335.76 17 15.23 812 2 3
5 8 0.36 175 15.27 307 2 7

Cycle 24 GMT 10/ 7/2020 15:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 28 15.21 486 2 3
2 7 2005.36 53 15.03 3070 2 3
3 13 1001.36 17 15.08 1737 2 3
4 13 407.24 17 15.22 912 2 3
5 13 24.76 17 15.31 341 2 2
6 8 0.16 175 15.27 302 2 3

Cycle 23 GMT 30/ 6/2020 18:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 28 15.21 491 2 3
2 7 2008.68 53 15.01 3076 2 3
3 13 1003.60 17 15.07 1734 2 3
4 13 287.44 17 15.24 739 2 3
5 13 31.32 17 15.30 345 2 3
6 8 -0.04 175 15.27 295 2 3

Cycle 22 GMT 20/ 6/2020 20:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 28 15.23 475 2 3
2 7 2005.84 53 15.03 3071 2 2
3 13 1001.12 17 15.08 1732 2 3
4 13 410.28 17 15.21 914 2 3
5 13 49.32 17 15.30 377 2 3
6 8 0.00 175 15.27 303 2 3

Cycle 21 GMT 10/ 6/2020 23:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 15.23 461 2 3
2 7 2009.20 52 15.03 3076 2 2
3 13 996.48 17 15.08 1731 2 3
4 13 403.44 17 15.22 905 2 3
5 13 22.92 17 15.31 336 2 3
6 8 0.00 165 15.28 298 2 3

Cycle 20 GMT 1/ 6/2020 1:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 28 15.22 480 2 3
2 7 2007.04 53 15.02 3078 2 3
3 13 1002.12 17 15.08 1735 2 3
4 13 410.44 17 15.22 914 2 3
5 13 51.24 17 15.30 378 2 3
6 8 0.24 165 15.28 294 2 5

Cycle 19 GMT 22/ 5/2020 4:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 28 15.23 474 2 3
2 7 2003.88 53 15.03 3063 2 2
3 13 1005.36 17 15.09 1743 2 3
4 13 410.08 17 15.22 917 2 3
5 13 55.08 17 15.31 388 2 3
6 8 -0.16 165 15.28 296 2 4
7 14 -0.16 30 15.26 291 2 3

Cycle 18 GMT 12/ 5/2020 6:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 28 15.24 458 2 3
2 7 2004.64 53 15.04 3076 2 2
3 13 992.76 17 15.09 1716 2 3
4 13 279.80 17 15.26 728 2 3
5 13 32.16 17 15.32 343 2 3
6 8 -0.04 165 15.28 293 2 4

Cycle 17 GMT 2/ 5/2020 9: 5: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 28 15.23 484 2 3
2 7 2011.44 53 15.04 3087 2 2
3 13 1007.44 17 15.08 1737 2 3
4 13 410.36 17 15.23 917 2 3
5 13 50.96 17 15.31 381 2 3
6 8 0.04 165 15.29 293 2 3

Cycle 16 GMT 22/ 4/2020 11:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 28 15.24 480 2 3
2 7 2005.00 53 15.05 3077 2 2
3 13 884.16 17 15.13 1574 2 3
4 13 328.52 17 15.25 801 2 3
5 13 43.08 17 15.32 365 2 3
6 8 -0.04 165 15.29 296 2 3
7 14 -0.04 30 15.27 297 2 4

Cycle 15 GMT 12/ 4/2020 13:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 28 15.24 479 2 3
2 7 2008.08 52 15.04 3075 2 2
3 13 886.96 17 15.13 1576 2 3
4 13 326.16 17 15.25 794 2 3
5 13 43.00 17 15.32 368 2 2
6 8 0.08 165 15.29 296 2 3

Cycle 14 GMT 2/ 4/2020 16: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.24 452 2 3
2 7 2004.40 53 15.05 3072 2 2
3 13 987.64 17 15.12 1707 2 3
4 13 275.52 17 15.28 716 2 3
5 13 59.64 17 15.33 393 2 2
6 8 0.08 165 15.30 297 2 3

Cycle 13 GMT 23/ 3/2020 18:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 28 15.25 475 3 3
2 7 2003.08 53 15.06 3074 2 2
3 13 878.96 17 15.14 1573 2 3
4 13 316.40 17 15.26 785 2 3
5 13 41.96 17 15.33 365 2 2
6 8 -0.04 165 15.29 296 2 3

Cycle 12 GMT 13/ 3/2020 20:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 15.25 452 3 3
2 7 2004.28 53 15.07 3070 2 2
3 13 990.36 17 15.12 1707 2 3
4 13 400.36 17 15.25 901 2 3
5 13 48.28 17 15.33 374 2 3
6 8 0.20 165 15.31 293 2 5

Cycle 11 GMT 3/ 3/2020 23:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.25 454 3 3
2 7 2006.80 53 15.06 3063 2 3
3 13 998.28 17 15.12 1725 2 3
4 13 279.04 17 15.29 729 2 3
5 13 37.08 17 15.34 355 2 3
6 8 -0.08 165 15.31 295 2 4

Cycle 10 GMT 23/ 2/2020 1:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 28 15.26 472 3 3
2 7 2004.96 52 15.06 3087 2 2
3 13 995.72 17 15.12 1724 2 3
4 13 398.20 17 15.25 895 2 3
5 13 49.72 17 15.33 377 2 2
6 8 -0.08 165 15.30 294 2 6

Cycle 9 GMT 13/ 2/2020 4: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 28 15.25 448 3 3
2 7 2004.12 53 15.08 3054 2 2
3 13 875.72 17 15.16 1566 2 3
4 13 310.60 17 15.29 778 2 3
5 13 37.20 17 15.35 362 2 3
6 8 0.12 165 15.31 293 2 4

Cycle 8 GMT 3/ 2/2020 6:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.88 28 15.26 485 3 3
2 7 2004.12 52 15.07 3075 2 2
3 13 989.60 18 15.12 1715 2 3
4 13 255.92 18 15.29 694 2 3
5 13 29.32 18 15.34 346 2 2
6 8 0.12 165 15.31 293 2 4

Cycle 7 GMT 24/ 1/2020 8:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 28 15.26 474 3 3
2 7 2001.84 53 15.07 3073 2 2
3 13 977.12 18 15.13 1702 2 3
4 13 242.60 18 15.31 670 2 3
5 13 22.72 18 15.35 334 2 2
6 8 -0.04 165 15.31 295 2 3

Cycle 6 GMT 14/ 1/2020 11: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 26 15.25 479 2 3
2 3 1060.52 2 15.27 1886 2 3
3 7 2004.68 74 14.84 3032 2 2
4 13 322.92 18 15.28 788 2 3
5 13 34.04 18 15.35 350 2 3
6 8 0.04 165 15.31 293 2 3

Cycle 5 GMT 4/ 1/2020 13:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 25 15.26 480 2 3
2 10 1028.68 2 15.22 1819 2 3
3 7 2006.60 74 14.83 3041 2 2
4 13 325.96 18 15.28 793 2 3
5 13 32.84 18 15.35 351 2 2
6 8 0.16 165 15.32 291 2 3

Cycle 4 GMT 25/12/2019 16:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 26 15.27 471 2 3
2 7 1524.92 74 14.98 2402 2 3
3 13 106.52 18 15.34 466 2 3
4 8 -0.16 165 15.32 291 2 2
5 14 -0.16 75 15.29 289 2 3

Cycle 3 GMT 24/12/2019 17:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 26 15.29 449 2 3
2 3 1016.28 1 15.34 1801 2 2
3 7 1524.12 74 14.99 2387 2 3
4 13 110.36 18 15.35 452 2 3
5 13 22.32 18 15.36 311 2 2
6 8 0.12 165 15.32 283 2 3

Cycle 2 GMT 23/12/2019 17:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 26 15.30 454 2 3
2 7 1524.40 74 15.00 2384 2 3
3 13 121.20 18 15.35 469 2 3
4 8 0.16 165 15.34 273 2 3

Cycle 1 GMT 22/12/2019 18:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 23 15.46 419 3 3
2 10 1022.92 3 15.30 1781 2 3
3 3 1024.84 1 15.35 1795 2 2
4 7 1002.48 74 15.16 1675 2 3
5 8 0.00 165 15.38 273 2 3
6 14 0.00 75 15.34 268 2 4

Cycle 0 GMT 22/12/2019 7:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 98.60 22 15.59 408 3 3
2 7 112.20 74 15.56 410 3 3
3 8 0.12 240 15.53 240 3 6