SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 3309 WMO= 3902520


Cycle 8 GMT 13/ 1/2025 6:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 31 15.24 427 2 4
2 7 2004.16 74 14.87 2757 2 7
3 13 606.04 18 15.21 1056 2 11
4 13 39.60 18 15.34 331 2 12
5 8 0.16 165 15.30 280 2 18

Cycle 7 GMT 3/ 1/2025 9:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 15.24 424 2 4
2 3 1021.48 1 15.34 1625 2 6
3 7 1777.72 74 14.94 2493 2 7
4 13 405.52 18 15.25 794 2 11
5 13 23.12 18 15.34 307 2 11
6 8 0.08 165 15.30 278 2 18

Cycle 6 GMT 2/ 1/2025 8:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 30 15.26 428 2 5
2 7 1784.40 74 14.93 2504 2 7
3 13 461.48 18 15.24 870 2 11
4 13 22.80 18 15.33 308 2 11
5 8 0.16 165 15.29 278 2 20

Cycle 5 GMT 1/ 1/2025 7:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 30 15.26 429 2 4
2 3 1018.20 1 15.36 1628 2 5
3 7 1523.60 75 15.03 2196 2 7
4 13 208.68 18 15.32 550 2 11
5 8 0.20 165 15.32 276 2 16

Cycle 4 GMT 31/12/2024 7:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 29 15.27 421 2 4
2 3 1019.08 1 15.35 1632 2 5
3 7 1509.40 74 15.04 2179 2 8
4 13 261.52 18 15.33 621 2 11
5 8 0.12 165 15.32 280 2 16

Cycle 3 GMT 30/12/2024 8:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 26 15.26 418 2 4
2 10 1038.12 3 15.25 1630 2 4
3 3 1045.84 1 15.32 1658 2 6
4 7 1522.96 74 15.03 2183 2 7
5 13 220.88 18 15.32 563 2 11
6 8 -0.16 165 15.32 277 2 18

Cycle 2 GMT 29/12/2024 8:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 33 15.32 411 2 5
2 3 853.44 -3 15.68 0 2 5
3 3 909.08 -2 15.67 0 2 5
4 7 1507.96 74 15.05 2156 2 7
5 13 299.80 18 15.31 656 2 11
6 8 0.16 165 15.32 273 2 17

Cycle 1 GMT 28/12/2024 8:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 28 15.49 367 2 3
2 3 1022.04 1 15.37 1618 2 4
3 7 1003.80 74 15.22 1536 2 10
4 8 0.00 165 15.39 264 2 18

Cycle 0 GMT 27/12/2024 22: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.00 28 15.62 312 3 3
2 7 73.56 74 15.59 329 3 4
3 8 0.40 240 15.55 225 3 12