SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.20 | 44 | 10.57 | 500 | 6 | 6 |
2 | 1050.88 | 1 | 8.00 | 1700 | 6 | 6 |
3 | 1050.56 | 80 | 7.42 | 1730 | 6 | 6 |
4 | 861.60 | 40 | 8.15 | 1478 | 6 | 6 |
5 | 158.08 | 40 | 10.06 | 612 | 6 | 6 |
6 | 43.16 | 40 | 10.43 | 457 | 6 | 6 |
7 | 22.32 | 40 | 10.48 | 427 | 6 | 6 |
8 | 0.16 | 40 | 10.60 | 398 | 6 | 6 |
9 | 0.08 | 181 | 10.59 | 397 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.96 | 45 | 10.57 | 500 | 6 | 6 |
2 | 1020.68 | 81 | 7.70 | 1640 | 6 | 6 |
3 | 633.88 | 40 | 8.82 | 1198 | 6 | 6 |
4 | 75.92 | 40 | 10.32 | 505 | 6 | 6 |
5 | 46.92 | 40 | 10.43 | 461 | 6 | 6 |
6 | 0.24 | 40 | 10.60 | 400 | 6 | 6 |
7 | 0.24 | 181 | 10.62 | 387 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.36 | 45 | 10.57 | 500 | 6 | 6 |
2 | 1026.20 | 81 | 7.84 | 1634 | 6 | 6 |
3 | 639.36 | 40 | 8.81 | 1216 | 6 | 7 |
4 | 75.84 | 40 | 10.34 | 502 | 6 | 6 |
5 | 24.72 | 40 | 10.51 | 438 | 6 | 6 |
6 | 17.88 | 40 | 10.54 | 426 | 6 | 6 |
7 | 5.88 | 40 | 10.58 | 405 | 6 | 6 |
8 | 0.12 | 41 | 10.62 | 402 | 6 | 6 |
9 | 0.04 | 180 | 10.63 | 390 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.80 | 45 | 10.57 | 520 | 6 | 6 |
2 | 1024.00 | 81 | 7.86 | 1664 | 6 | 6 |
3 | 542.36 | 40 | 9.06 | 1127 | 6 | 6 |
4 | 73.84 | 40 | 10.37 | 513 | 6 | 6 |
5 | 38.80 | 40 | 10.45 | 467 | 6 | 6 |
6 | 0.28 | 40 | 10.63 | 410 | 6 | 6 |
7 | 0.20 | 181 | 10.62 | 401 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.52 | 43 | 10.50 | 540 | 6 | 6 |
2 | 1053.52 | 1 | 8.00 | 1760 | 6 | 6 |
3 | 1908.36 | 81 | 5.62 | 3001 | 6 | 6 |
4 | 1893.88 | 41 | 6.29 | 2732 | 6 | 6 |
5 | 1847.16 | 41 | 6.33 | 2690 | 6 | 6 |
6 | 1779.84 | 41 | 6.48 | 2627 | 6 | 6 |
7 | 1695.52 | 41 | 6.69 | 2496 | 6 | 6 |
8 | 1411.20 | 41 | 7.32 | 2157 | 6 | 6 |
9 | 1099.12 | 41 | 7.90 | 1807 | 6 | 6 |
10 | 677.32 | 41 | 8.86 | 1315 | 6 | 6 |
11 | 61.40 | 41 | 10.44 | 511 | 6 | 6 |
12 | 18.32 | 41 | 10.53 | 451 | 6 | 6 |
13 | 0.16 | 40 | 10.64 | 423 | 6 | 6 |
14 | 0.12 | 181 | 10.65 | 410 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.44 | 42 | 10.63 | 540 | 6 | 6 |
2 | 1084.04 | 2 | 8.07 | 1780 | 6 | 6 |
3 | 1075.08 | 81 | 7.70 | 1780 | 6 | 6 |
4 | 710.12 | 40 | 8.70 | 1345 | 6 | 6 |
5 | 194.76 | 40 | 10.04 | 690 | 6 | 6 |
6 | 49.60 | 40 | 10.44 | 488 | 6 | 6 |
7 | 0.28 | 40 | 10.63 | 416 | 6 | 6 |
8 | 0.28 | 181 | 10.64 | 403 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 45 | 10.63 | 520 | 6 | 6 |
2 | 1031.56 | 81 | 8.00 | 1665 | 6 | 6 |
3 | 542.48 | 40 | 9.20 | 1133 | 6 | 6 |
4 | 90.24 | 40 | 10.34 | 550 | 6 | 6 |
5 | 49.08 | 40 | 10.48 | 485 | 6 | 6 |
6 | 0.16 | 40 | 10.67 | 411 | 6 | 6 |
7 | 0.12 | 181 | 10.67 | 404 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.04 | 44 | 10.63 | 520 | 6 | 6 |
2 | 1021.76 | 81 | 8.09 | 1654 | 6 | 6 |
3 | 558.52 | 40 | 9.24 | 1115 | 6 | 6 |
4 | 78.28 | 40 | 10.41 | 525 | 6 | 6 |
5 | 41.48 | 40 | 10.48 | 475 | 6 | 6 |
6 | 0.32 | 180 | 10.66 | 406 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.52 | 44 | 10.69 | 520 | 6 | 6 |
2 | 1031.40 | 81 | 8.13 | 1716 | 6 | 6 |
3 | 547.20 | 40 | 9.24 | 1155 | 6 | 6 |
4 | 84.80 | 40 | 10.40 | 546 | 6 | 6 |
5 | 52.92 | 40 | 10.53 | 495 | 6 | 6 |
6 | 0.40 | 40 | 10.72 | 411 | 6 | 6 |
7 | 0.36 | 181 | 10.70 | 402 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.44 | 41 | 10.57 | 540 | 6 | 6 |
2 | 1086.36 | 2 | 8.13 | 1860 | 6 | 6 |
3 | 1901.80 | 81 | 6.67 | 2728 | 6 | 6 |
4 | 1851.88 | 41 | 6.83 | 2731 | 6 | 6 |
5 | 1771.76 | 41 | 7.07 | 2625 | 6 | 6 |
6 | 1585.32 | 41 | 7.47 | 2393 | 6 | 6 |
7 | 1122.60 | 41 | 8.20 | 1872 | 6 | 6 |
8 | 628.68 | 41 | 9.21 | 1267 | 6 | 6 |
9 | 99.96 | 41 | 10.44 | 567 | 6 | 6 |
10 | 58.00 | 41 | 10.56 | 502 | 6 | 6 |
11 | 0.28 | 40 | 10.74 | 418 | 6 | 6 |
12 | 0.20 | 181 | 10.75 | 401 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.20 | 39 | 10.50 | 540 | 6 | 6 |
2 | 1115.80 | 2 | 8.25 | 1840 | 6 | 6 |
3 | 1101.84 | 81 | 8.21 | 1799 | 6 | 6 |
4 | 800.44 | 40 | 8.88 | 1465 | 6 | 6 |
5 | 91.00 | 40 | 10.44 | 545 | 6 | 6 |
6 | 62.72 | 40 | 10.56 | 493 | 6 | 6 |
7 | 0.32 | 40 | 10.79 | 401 | 6 | 6 |
8 | 0.20 | 181 | 10.75 | 398 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.52 | 44 | 10.69 | 520 | 6 | 6 |
2 | 1032.52 | 81 | 8.38 | 1654 | 6 | 6 |
3 | 633.12 | 40 | 9.37 | 1165 | 6 | 6 |
4 | 95.04 | 40 | 10.57 | 477 | 6 | 6 |
5 | 59.08 | 40 | 10.59 | 493 | 6 | 6 |
6 | 0.16 | 41 | 10.77 | 400 | 6 | 6 |
7 | 0.08 | 180 | 10.75 | 392 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.68 | 43 | 10.75 | 520 | 6 | 6 |
2 | 1019.12 | 81 | 8.46 | 1655 | 6 | 6 |
3 | 532.20 | 40 | 9.60 | 1052 | 6 | 6 |
4 | 97.48 | 40 | 10.56 | 475 | 6 | 6 |
5 | 55.96 | 40 | 10.63 | 466 | 6 | 6 |
6 | 0.20 | 41 | 10.79 | 401 | 6 | 6 |
7 | 0.20 | 180 | 10.77 | 393 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.84 | 43 | 10.75 | 520 | 6 | 6 |
2 | 1024.20 | 81 | 8.60 | 1642 | 6 | 6 |
3 | 527.52 | 40 | 9.58 | 1051 | 6 | 6 |
4 | 73.92 | 40 | 10.64 | 466 | 6 | 6 |
5 | 47.08 | 40 | 10.64 | 477 | 6 | 6 |
6 | 0.28 | 180 | 10.77 | 398 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.64 | 38 | 10.69 | 520 | 6 | 6 |
2 | 1139.56 | 3 | 8.57 | 1820 | 6 | 6 |
3 | 1903.60 | 81 | 7.06 | 2709 | 6 | 6 |
4 | 1829.40 | 41 | 7.35 | 2683 | 6 | 6 |
5 | 1659.04 | 41 | 7.60 | 2506 | 6 | 6 |
6 | 1386.20 | 41 | 8.08 | 2190 | 6 | 6 |
7 | 798.12 | 41 | 9.09 | 1485 | 6 | 6 |
8 | 103.92 | 41 | 10.51 | 576 | 6 | 6 |
9 | 67.12 | 41 | 10.62 | 521 | 6 | 6 |
10 | 0.28 | 40 | 10.81 | 422 | 6 | 6 |
11 | 0.16 | 181 | 10.78 | 408 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.24 | 36 | 10.69 | 520 | 6 | 6 |
2 | 1124.12 | 3 | 8.69 | 1760 | 6 | 6 |
3 | 1143.44 | 81 | 8.42 | 1822 | 6 | 6 |
4 | 763.96 | 40 | 9.14 | 1406 | 6 | 6 |
5 | 150.64 | 40 | 10.37 | 641 | 6 | 6 |
6 | 47.08 | 40 | 10.65 | 490 | 6 | 6 |
7 | 0.16 | 40 | 10.79 | 421 | 6 | 6 |
8 | 0.20 | 181 | 10.77 | 402 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.76 | 42 | 10.75 | 520 | 6 | 6 |
2 | 1033.08 | 81 | 8.46 | 1720 | 6 | 6 |
3 | 536.52 | 40 | 9.56 | 1110 | 6 | 6 |
4 | 73.40 | 40 | 10.55 | 522 | 6 | 6 |
5 | 47.12 | 40 | 10.65 | 476 | 6 | 6 |
6 | 0.24 | 41 | 10.79 | 407 | 6 | 6 |
7 | 0.16 | 180 | 10.76 | 397 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.32 | 40 | 10.75 | 520 | 6 | 6 |
2 | 1084.32 | 2 | 8.88 | 1780 | 6 | 6 |
3 | 1071.28 | 80 | 8.61 | 1703 | 6 | 6 |
4 | 764.72 | 40 | 9.27 | 1352 | 6 | 6 |
5 | 114.24 | 40 | 10.58 | 503 | 6 | 6 |
6 | 63.64 | 40 | 10.69 | 447 | 6 | 6 |
7 | 0.24 | 41 | 10.81 | 411 | 6 | 6 |
8 | 0.16 | 180 | 10.78 | 401 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 37 | 10.82 | 520 | 6 | 6 |
2 | 1129.00 | 3 | 9.00 | 1840 | 6 | 6 |
3 | 1107.76 | 81 | 8.71 | 1802 | 6 | 6 |
4 | 617.76 | 40 | 9.54 | 1251 | 6 | 6 |
5 | 86.56 | 40 | 10.57 | 562 | 6 | 6 |
6 | 57.44 | 40 | 10.63 | 511 | 6 | 6 |
7 | 0.20 | 41 | 10.84 | 415 | 6 | 6 |
8 | 0.12 | 180 | 10.81 | 404 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.44 | 32 | 11.19 | 480 | 6 | 6 |
2 | 1228.56 | 5 | 9.19 | 1940 | 6 | 6 |
3 | 1907.12 | 81 | 6.27 | 2769 | 6 | 7 |
4 | 1850.04 | 41 | 7.03 | 2703 | 6 | 6 |
5 | 1767.20 | 41 | 7.49 | 2567 | 6 | 6 |
6 | 1577.60 | 40 | 7.84 | 2353 | 6 | 6 |
7 | 1095.88 | 40 | 8.82 | 1785 | 6 | 6 |
8 | 567.08 | 40 | 9.76 | 1143 | 6 | 6 |
9 | 75.88 | 40 | 10.69 | 502 | 6 | 6 |
10 | 44.72 | 40 | 10.74 | 442 | 6 | 6 |
11 | 0.20 | 40 | 10.95 | 327 | 6 | 6 |
12 | 0.20 | 181 | 10.85 | 377 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 32 | 11.25 | 520 | 6 | 6 |
2 | 1145.00 | 3 | 9.63 | 1900 | 6 | 6 |
3 | 1163.56 | 81 | 8.71 | 1888 | 6 | 6 |
4 | 669.24 | 40 | 9.72 | 1270 | 6 | 6 |
5 | 80.60 | 40 | 10.97 | 532 | 6 | 6 |
6 | 53.32 | 40 | 10.99 | 497 | 6 | 6 |
7 | 0.28 | 40 | 11.23 | 410 | 6 | 6 |
8 | 0.20 | 181 | 11.07 | 401 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.96 | 34 | 11.88 | 520 | 6 | 6 |
2 | 1106.88 | 2 | 10.69 | 1860 | 6 | 6 |
3 | 1059.92 | 84 | 5.03 | 1660 | 6 | 7 |
4 | 955.04 | 40 | 7.75 | 1617 | 6 | 6 |
5 | 790.16 | 40 | 8.69 | 1435 | 6 | 6 |
6 | 377.40 | 40 | 10.10 | 936 | 6 | 6 |
7 | 69.84 | 40 | 11.04 | 525 | 6 | 6 |
8 | 40.60 | 40 | 11.09 | 473 | 6 | 6 |
9 | 0.28 | 180 | 11.11 | 403 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.44 | 33 | 13.00 | 500 | 6 | 6 |
2 | 1045.00 | 1 | 11.75 | 1780 | 6 | 6 |
3 | 1044.16 | 81 | 5.59 | 1683 | 6 | 6 |
4 | 955.88 | 40 | 8.21 | 1616 | 6 | 6 |
5 | 567.88 | 40 | 10.15 | 1163 | 6 | 6 |
6 | 71.32 | 40 | 11.71 | 531 | 6 | 6 |
7 | 44.80 | 40 | 11.73 | 485 | 6 | 6 |
8 | 0.16 | 180 | 11.65 | 408 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.28 | 32 | 13.37 | 540 | 6 | 6 |
2 | 1022.80 | 81 | 7.02 | 1700 | 6 | 6 |
3 | 931.92 | 40 | 9.49 | 1621 | 6 | 6 |
4 | 297.68 | 40 | 11.94 | 846 | 6 | 6 |
5 | 44.52 | 40 | 12.81 | 500 | 6 | 6 |
6 | 22.76 | 40 | 12.69 | 457 | 6 | 6 |
7 | 0.24 | 40 | 12.79 | 427 | 6 | 6 |
8 | 0.16 | 181 | 12.27 | 408 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.24 | 32 | 13.93 | 520 | 6 | 6 |
2 | 1903.24 | 81 | 5.68 | 2742 | 6 | 7 |
3 | 1879.20 | 41 | 8.75 | 2768 | 6 | 6 |
4 | 1812.56 | 41 | 8.58 | 2715 | 6 | 6 |
5 | 1425.64 | 41 | 9.45 | 2270 | 6 | 6 |
6 | 911.56 | 40 | 10.66 | 1655 | 6 | 6 |
7 | 84.32 | 41 | 13.01 | 571 | 6 | 6 |
8 | 45.88 | 41 | 13.01 | 512 | 6 | 6 |
9 | 0.20 | 180 | 12.76 | 418 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.24 | 32 | 13.87 | 540 | 6 | 6 |
2 | 1015.60 | 80 | 4.97 | 1537 | 6 | 6 |
3 | 954.84 | 40 | 8.46 | 1627 | 6 | 6 |
4 | 866.20 | 40 | 9.33 | 1522 | 6 | 6 |
5 | 118.64 | 41 | 13.36 | 600 | 6 | 6 |
6 | 36.72 | 41 | 13.74 | 488 | 6 | 6 |
7 | 0.20 | 180 | 13.39 | 402 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.80 | 32 | 13.93 | 520 | 6 | 6 |
2 | 1010.84 | 81 | 5.61 | 1573 | 6 | 6 |
3 | 940.80 | 40 | 9.07 | 1622 | 6 | 6 |
4 | 550.64 | 40 | 11.90 | 1170 | 6 | 6 |
5 | 49.12 | 40 | 13.69 | 516 | 6 | 6 |
6 | 28.04 | 40 | 13.76 | 478 | 6 | 6 |
7 | 0.16 | 40 | 13.97 | 431 | 6 | 6 |
8 | 0.12 | 181 | 13.17 | 406 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.08 | 32 | 14.00 | 540 | 6 | 6 |
2 | 1011.64 | 81 | 6.42 | 1601 | 6 | 6 |
3 | 928.48 | 40 | 9.61 | 1616 | 6 | 6 |
4 | 218.08 | 40 | 13.15 | 743 | 6 | 6 |
5 | 43.80 | 40 | 13.80 | 506 | 6 | 6 |
6 | 0.24 | 40 | 14.03 | 437 | 6 | 6 |
7 | 0.16 | 181 | 13.24 | 412 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 32 | 14.12 | 540 | 6 | 6 |
2 | 999.00 | 81 | 7.33 | 1618 | 6 | 6 |
3 | 723.56 | 40 | 11.80 | 1336 | 6 | 6 |
4 | 74.92 | 40 | 13.71 | 546 | 6 | 6 |
5 | 19.92 | 40 | 13.90 | 481 | 6 | 6 |
6 | 0.32 | 40 | 14.06 | 436 | 6 | 6 |
7 | 0.24 | 181 | 13.36 | 406 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.40 | 32 | 13.93 | 540 | 6 | 6 |
2 | 1901.76 | 81 | 7.34 | 2717 | 6 | 6 |
3 | 1824.00 | 41 | 9.53 | 2748 | 6 | 6 |
4 | 1448.56 | 41 | 11.01 | 2323 | 6 | 6 |
5 | 711.92 | 41 | 12.48 | 1421 | 6 | 6 |
6 | 43.28 | 41 | 13.90 | 528 | 6 | 6 |
7 | 27.16 | 41 | 13.97 | 497 | 6 | 6 |
8 | 0.24 | 41 | 14.12 | 446 | 6 | 6 |
9 | 0.16 | 180 | 13.42 | 423 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.92 | 32 | 14.00 | 540 | 6 | 6 |
2 | 1003.48 | 81 | 6.57 | 1604 | 6 | 6 |
3 | 910.20 | 40 | 10.40 | 1597 | 6 | 6 |
4 | 188.92 | 40 | 13.34 | 712 | 6 | 6 |
5 | 36.76 | 40 | 13.84 | 502 | 6 | 6 |
6 | 0.44 | 181 | 13.57 | 429 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.80 | 32 | 14.06 | 520 | 6 | 6 |
2 | 1000.28 | 81 | 6.88 | 1595 | 6 | 6 |
3 | 818.48 | 40 | 11.39 | 1452 | 6 | 6 |
4 | 81.36 | 40 | 13.73 | 547 | 6 | 6 |
5 | 26.24 | 40 | 13.90 | 487 | 6 | 6 |
6 | 0.28 | 40 | 14.04 | 441 | 6 | 6 |
7 | 0.20 | 181 | 13.46 | 419 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.64 | 32 | 14.12 | 500 | 6 | 6 |
2 | 990.84 | 81 | 6.96 | 1612 | 6 | 6 |
3 | 807.44 | 40 | 11.35 | 1463 | 6 | 6 |
4 | 84.80 | 40 | 13.74 | 540 | 6 | 6 |
5 | 23.36 | 40 | 13.98 | 445 | 6 | 6 |
6 | 0.24 | 40 | 14.06 | 428 | 6 | 6 |
7 | 0.20 | 181 | 13.54 | 410 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.08 | 32 | 14.18 | 500 | 6 | 6 |
2 | 990.72 | 80 | 7.60 | 1598 | 6 | 6 |
3 | 616.08 | 40 | 12.34 | 1197 | 6 | 6 |
4 | 49.64 | 40 | 13.95 | 458 | 6 | 6 |
5 | 27.08 | 40 | 14.00 | 428 | 6 | 6 |
6 | 0.24 | 40 | 14.10 | 391 | 6 | 6 |
7 | 0.12 | 181 | 13.79 | 374 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.88 | 32 | 14.06 | 480 | 6 | 6 |
2 | 1903.44 | 81 | 7.51 | 2731 | 6 | 6 |
3 | 1827.44 | 41 | 9.93 | 2701 | 6 | 6 |
4 | 1535.72 | 41 | 11.18 | 2366 | 6 | 6 |
5 | 592.36 | 41 | 12.92 | 1216 | 6 | 6 |
6 | 56.16 | 41 | 13.99 | 485 | 6 | 6 |
7 | 14.84 | 41 | 14.10 | 427 | 6 | 6 |
8 | 0.16 | 180 | 13.95 | 385 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.40 | 32 | 14.12 | 500 | 6 | 6 |
2 | 997.52 | 81 | 7.04 | 1613 | 6 | 6 |
3 | 805.56 | 40 | 11.56 | 1482 | 6 | 6 |
4 | 73.92 | 40 | 13.77 | 540 | 6 | 6 |
5 | 24.48 | 40 | 13.98 | 448 | 6 | 6 |
6 | 0.16 | 40 | 14.07 | 402 | 6 | 6 |
7 | 0.16 | 181 | 13.82 | 377 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.92 | 32 | 14.06 | 500 | 6 | 6 |
2 | 998.52 | 81 | 7.13 | 1622 | 6 | 6 |
3 | 718.08 | 40 | 11.85 | 1387 | 6 | 6 |
4 | 73.84 | 40 | 13.80 | 538 | 6 | 6 |
5 | 24.36 | 40 | 13.95 | 435 | 6 | 6 |
6 | 0.36 | 41 | 14.08 | 396 | 6 | 6 |
7 | 0.24 | 180 | 13.81 | 382 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.68 | 32 | 14.00 | 540 | 6 | 6 |
2 | 992.76 | 81 | 7.21 | 1654 | 6 | 6 |
3 | 722.76 | 40 | 11.89 | 1377 | 6 | 6 |
4 | 78.56 | 40 | 13.82 | 530 | 6 | 6 |
5 | 21.64 | 40 | 14.02 | 423 | 6 | 6 |
6 | 0.28 | 40 | 14.10 | 398 | 6 | 6 |
7 | 0.16 | 181 | 13.84 | 388 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.56 | 32 | 14.18 | 500 | 6 | 6 |
2 | 991.64 | 81 | 7.84 | 1636 | 6 | 6 |
3 | 602.00 | 40 | 12.50 | 1228 | 6 | 6 |
4 | 65.28 | 40 | 13.85 | 533 | 6 | 6 |
5 | 15.20 | 40 | 14.00 | 435 | 6 | 6 |
6 | 0.24 | 180 | 13.92 | 391 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.88 | 32 | 14.06 | 520 | 6 | 6 |
2 | 1904.08 | 81 | 7.66 | 2748 | 6 | 6 |
3 | 1835.32 | 41 | 10.35 | 2693 | 6 | 6 |
4 | 1255.64 | 41 | 11.87 | 2026 | 6 | 6 |
5 | 509.20 | 41 | 13.11 | 1101 | 6 | 6 |
6 | 62.60 | 41 | 13.97 | 493 | 6 | 6 |
7 | 0.36 | 40 | 14.15 | 402 | 6 | 6 |
8 | 0.24 | 181 | 13.87 | 399 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.40 | 32 | 14.12 | 520 | 6 | 6 |
2 | 1002.80 | 81 | 7.00 | 1627 | 6 | 6 |
3 | 911.64 | 40 | 11.31 | 1568 | 6 | 6 |
4 | 83.20 | 40 | 13.80 | 538 | 6 | 6 |
5 | 26.32 | 40 | 13.94 | 480 | 6 | 6 |
6 | 0.20 | 41 | 14.06 | 407 | 6 | 6 |
7 | 0.16 | 180 | 13.89 | 409 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.40 | 32 | 14.00 | 520 | 6 | 6 |
2 | 1002.52 | 81 | 7.12 | 1623 | 6 | 6 |
3 | 733.20 | 40 | 12.02 | 1396 | 6 | 6 |
4 | 84.96 | 40 | 13.80 | 547 | 6 | 6 |
5 | 21.48 | 40 | 14.01 | 427 | 6 | 6 |
6 | 0.20 | 40 | 14.08 | 398 | 6 | 6 |
7 | 0.08 | 181 | 13.89 | 401 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.92 | 32 | 14.12 | 500 | 6 | 6 |
2 | 988.28 | 81 | 7.22 | 1608 | 6 | 6 |
3 | 797.56 | 40 | 11.70 | 1466 | 6 | 6 |
4 | 74.24 | 40 | 13.83 | 530 | 6 | 6 |
5 | 19.12 | 40 | 13.98 | 418 | 6 | 6 |
6 | 0.24 | 41 | 14.05 | 402 | 6 | 6 |
7 | 0.16 | 180 | 13.93 | 395 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 32 | 14.12 | 580 | 6 | 6 |
2 | 1007.56 | 80 | 7.81 | 1622 | 6 | 6 |
3 | 616.52 | 40 | 12.59 | 1232 | 6 | 6 |
4 | 74.24 | 40 | 13.88 | 536 | 6 | 6 |
5 | 0.32 | 181 | 13.98 | 396 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.76 | 32 | 14.12 | 520 | 6 | 6 |
2 | 1901.68 | 81 | 8.15 | 2731 | 6 | 6 |
3 | 1816.52 | 41 | 10.67 | 2765 | 6 | 6 |
4 | 1116.48 | 41 | 12.04 | 1962 | 6 | 6 |
5 | 266.64 | 41 | 13.48 | 866 | 6 | 6 |
6 | 34.20 | 41 | 13.95 | 532 | 6 | 6 |
7 | 0.28 | 180 | 13.84 | 460 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.32 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1012.08 | 81 | 7.05 | 1600 | 6 | 6 |
3 | 829.68 | 40 | 11.76 | 1536 | 6 | 6 |
4 | 79.84 | 40 | 13.77 | 577 | 6 | 6 |
5 | 20.68 | 40 | 13.94 | 478 | 6 | 6 |
6 | 0.08 | 41 | 14.01 | 446 | 6 | 6 |
7 | 0.08 | 180 | 13.85 | 424 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.20 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1000.92 | 81 | 7.04 | 1615 | 6 | 6 |
3 | 817.60 | 40 | 11.87 | 1471 | 6 | 6 |
4 | 84.88 | 40 | 13.75 | 571 | 6 | 6 |
5 | 0.32 | 40 | 14.01 | 443 | 6 | 6 |
6 | 0.28 | 181 | 13.85 | 426 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.76 | 32 | 14.06 | 520 | 6 | 6 |
2 | 997.44 | 81 | 6.92 | 1601 | 6 | 6 |
3 | 828.84 | 40 | 11.65 | 1530 | 6 | 6 |
4 | 93.72 | 40 | 13.75 | 593 | 6 | 6 |
5 | 9.76 | 40 | 14.00 | 432 | 6 | 6 |
6 | 0.24 | 40 | 14.00 | 438 | 6 | 6 |
7 | 0.20 | 181 | 13.91 | 412 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 32 | 14.00 | 520 | 6 | 6 |
2 | 988.88 | 81 | 7.60 | 1562 | 6 | 6 |
3 | 707.80 | 40 | 12.34 | 1307 | 6 | 6 |
4 | 81.20 | 40 | 13.89 | 506 | 6 | 6 |
5 | 0.32 | 40 | 14.10 | 385 | 6 | 6 |
6 | 0.32 | 181 | 14.06 | 383 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.60 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1903.88 | 81 | 7.76 | 2742 | 6 | 6 |
3 | 1831.96 | 41 | 10.82 | 2715 | 6 | 6 |
4 | 1406.52 | 41 | 11.69 | 2261 | 6 | 6 |
5 | 325.32 | 41 | 13.47 | 886 | 6 | 6 |
6 | 58.36 | 41 | 13.93 | 528 | 6 | 6 |
7 | 0.24 | 40 | 14.10 | 430 | 6 | 6 |
8 | 0.20 | 181 | 14.06 | 403 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.28 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1015.32 | 81 | 6.41 | 1683 | 6 | 6 |
3 | 926.84 | 40 | 11.22 | 1663 | 6 | 6 |
4 | 307.32 | 40 | 13.33 | 875 | 6 | 7 |
5 | 44.36 | 40 | 13.92 | 508 | 6 | 6 |
6 | 0.28 | 180 | 13.96 | 440 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1005.08 | 81 | 6.41 | 1677 | 6 | 6 |
3 | 927.32 | 40 | 11.15 | 1680 | 6 | 6 |
4 | 195.20 | 40 | 13.55 | 740 | 6 | 6 |
5 | 44.60 | 40 | 13.87 | 522 | 6 | 6 |
6 | 0.32 | 180 | 13.94 | 443 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.08 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1016.60 | 81 | 6.90 | 1634 | 6 | 6 |
3 | 834.96 | 40 | 11.76 | 1561 | 6 | 6 |
4 | 99.32 | 40 | 13.73 | 616 | 6 | 6 |
5 | 49.96 | 40 | 13.87 | 527 | 6 | 6 |
6 | 0.16 | 180 | 13.96 | 442 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.48 | 32 | 14.12 | 540 | 6 | 6 |
2 | 993.84 | 80 | 7.47 | 1620 | 6 | 6 |
3 | 805.16 | 40 | 11.95 | 1460 | 6 | 6 |
4 | 113.12 | 40 | 13.81 | 560 | 6 | 6 |
5 | 0.32 | 40 | 14.04 | 427 | 6 | 6 |
6 | 0.36 | 181 | 13.94 | 437 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1903.72 | 81 | 8.12 | 2728 | 6 | 6 |
3 | 1827.56 | 41 | 11.06 | 2687 | 6 | 6 |
4 | 1109.48 | 41 | 12.27 | 1883 | 6 | 7 |
5 | 234.36 | 41 | 13.57 | 792 | 6 | 6 |
6 | 55.68 | 41 | 13.91 | 538 | 6 | 6 |
7 | 0.24 | 40 | 14.07 | 450 | 6 | 6 |
8 | 0.12 | 181 | 13.99 | 425 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1011.76 | 80 | 7.10 | 1593 | 6 | 6 |
3 | 825.12 | 40 | 12.28 | 1478 | 6 | 6 |
4 | 89.04 | 40 | 13.89 | 538 | 6 | 6 |
5 | 46.96 | 40 | 13.91 | 516 | 6 | 6 |
6 | 0.24 | 180 | 14.02 | 435 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 32 | 14.12 | 540 | 6 | 6 |
2 | 1404.12 | 81 | 6.46 | 2056 | 6 | 6 |
3 | 1413.76 | 41 | 11.11 | 2240 | 6 | 6 |
4 | 1328.32 | 41 | 11.41 | 2152 | 6 | 6 |
5 | 475.84 | 41 | 13.24 | 1097 | 6 | 6 |
6 | 80.76 | 41 | 13.88 | 577 | 6 | 6 |
7 | 0.24 | 40 | 14.07 | 447 | 6 | 6 |
8 | 0.20 | 181 | 14.02 | 433 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.84 | 32 | 14.12 | 540 | 6 | 6 |
2 | 1403.00 | 81 | 6.31 | 2104 | 6 | 6 |
3 | 1415.96 | 41 | 11.13 | 2247 | 6 | 6 |
4 | 1328.04 | 41 | 11.46 | 2155 | 6 | 6 |
5 | 488.68 | 41 | 13.19 | 1115 | 6 | 6 |
6 | 92.12 | 41 | 13.86 | 583 | 6 | 6 |
7 | 0.24 | 41 | 14.12 | 436 | 6 | 6 |
8 | 0.12 | 180 | 14.08 | 422 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.16 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1414.84 | 81 | 6.28 | 2126 | 6 | 6 |
3 | 1434.52 | 41 | 10.90 | 2253 | 6 | 6 |
4 | 1362.88 | 41 | 11.28 | 2165 | 6 | 6 |
5 | 612.72 | 41 | 13.00 | 1266 | 6 | 7 |
6 | 95.32 | 41 | 13.89 | 580 | 6 | 6 |
7 | 0.24 | 41 | 14.11 | 428 | 6 | 6 |
8 | 0.24 | 181 | 14.09 | 417 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.40 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1405.24 | 81 | 7.45 | 2160 | 6 | 6 |
3 | 1375.88 | 40 | 11.36 | 2211 | 6 | 6 |
4 | 1076.48 | 40 | 12.26 | 1841 | 6 | 6 |
5 | 120.48 | 40 | 13.81 | 626 | 6 | 6 |
6 | 67.52 | 40 | 13.94 | 533 | 6 | 6 |
7 | 0.24 | 40 | 14.10 | 432 | 6 | 6 |
8 | 0.20 | 181 | 14.05 | 423 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.92 | 32 | 14.12 | 540 | 6 | 6 |
2 | 1196.04 | 81 | 9.18 | 1916 | 6 | 6 |
3 | 1128.04 | 41 | 11.98 | 1911 | 6 | 6 |
4 | 626.64 | 41 | 12.96 | 1310 | 6 | 7 |
5 | 93.60 | 41 | 13.87 | 588 | 6 | 6 |
6 | 0.28 | 40 | 14.10 | 437 | 6 | 6 |
7 | 0.16 | 181 | 14.05 | 431 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.68 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1406.16 | 81 | 6.04 | 2069 | 6 | 6 |
3 | 1437.72 | 41 | 10.96 | 2288 | 6 | 6 |
4 | 1357.64 | 41 | 11.43 | 2182 | 6 | 6 |
5 | 537.44 | 41 | 13.10 | 1183 | 6 | 6 |
6 | 99.04 | 41 | 13.84 | 595 | 6 | 6 |
7 | 0.16 | 40 | 14.10 | 427 | 6 | 6 |
8 | 0.08 | 181 | 14.05 | 425 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.28 | 32 | 14.12 | 540 | 6 | 6 |
2 | 1403.60 | 81 | 6.34 | 2084 | 6 | 6 |
3 | 1421.64 | 41 | 11.20 | 2227 | 6 | 6 |
4 | 1334.88 | 41 | 11.57 | 2136 | 6 | 6 |
5 | 585.36 | 41 | 13.05 | 1226 | 6 | 6 |
6 | 86.16 | 41 | 13.86 | 561 | 6 | 6 |
7 | 8.40 | 41 | 14.09 | 430 | 6 | 6 |
8 | 0.16 | 40 | 14.13 | 433 | 6 | 6 |
9 | 0.08 | 181 | 14.06 | 426 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.00 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1405.80 | 81 | 6.26 | 2080 | 6 | 6 |
3 | 1431.84 | 41 | 10.97 | 2242 | 6 | 6 |
4 | 1346.60 | 41 | 11.44 | 2138 | 6 | 6 |
5 | 514.64 | 41 | 13.16 | 1123 | 6 | 6 |
6 | 75.84 | 41 | 13.84 | 561 | 6 | 6 |
7 | 0.72 | 180 | 14.01 | 418 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.60 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1405.56 | 81 | 7.37 | 2117 | 6 | 6 |
3 | 1373.08 | 41 | 11.47 | 2161 | 6 | 6 |
4 | 999.80 | 41 | 12.42 | 1738 | 6 | 6 |
5 | 137.80 | 41 | 13.74 | 653 | 6 | 6 |
6 | 30.56 | 41 | 13.97 | 472 | 6 | 6 |
7 | 0.16 | 40 | 14.02 | 460 | 6 | 6 |
8 | 0.20 | 181 | 13.89 | 437 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.08 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1175.44 | 81 | 9.16 | 1870 | 6 | 6 |
3 | 1110.24 | 41 | 12.09 | 1868 | 6 | 6 |
4 | 513.08 | 41 | 13.10 | 1162 | 6 | 6 |
5 | 46.76 | 41 | 13.88 | 542 | 6 | 6 |
6 | 23.88 | 41 | 13.96 | 495 | 6 | 6 |
7 | 0.12 | 41 | 14.06 | 456 | 6 | 6 |
8 | 0.08 | 180 | 13.93 | 432 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.48 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1402.56 | 81 | 5.75 | 2083 | 6 | 6 |
3 | 1448.84 | 41 | 11.14 | 2231 | 6 | 6 |
4 | 1373.64 | 41 | 11.55 | 2201 | 6 | 6 |
5 | 746.96 | 41 | 12.75 | 1481 | 6 | 6 |
6 | 68.76 | 41 | 13.80 | 582 | 6 | 6 |
7 | 8.00 | 41 | 13.99 | 476 | 6 | 6 |
8 | 0.16 | 41 | 14.05 | 461 | 6 | 6 |
9 | 0.16 | 180 | 13.95 | 434 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.80 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1403.52 | 81 | 6.32 | 2042 | 6 | 6 |
3 | 1426.72 | 41 | 11.15 | 2287 | 6 | 6 |
4 | 1339.12 | 41 | 11.61 | 2170 | 6 | 6 |
5 | 592.56 | 41 | 13.04 | 1231 | 6 | 6 |
6 | 53.68 | 41 | 13.85 | 536 | 6 | 6 |
7 | 0.32 | 40 | 14.04 | 440 | 6 | 6 |
8 | 0.28 | 181 | 13.88 | 444 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.08 | 32 | 14.00 | 540 | 6 | 6 |
2 | 1405.88 | 81 | 5.89 | 2107 | 6 | 6 |
3 | 1454.24 | 41 | 10.92 | 2297 | 6 | 6 |
4 | 1373.08 | 41 | 11.49 | 2190 | 6 | 6 |
5 | 655.88 | 41 | 12.89 | 1335 | 6 | 7 |
6 | 58.60 | 41 | 13.88 | 525 | 6 | 6 |
7 | 33.48 | 41 | 13.97 | 483 | 6 | 6 |
8 | 0.24 | 40 | 14.11 | 420 | 6 | 6 |
9 | 0.08 | 181 | 13.99 | 427 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.12 | 32 | 14.00 | 520 | 6 | 6 |
2 | 1404.92 | 81 | 7.18 | 2151 | 6 | 6 |
3 | 1373.88 | 41 | 11.50 | 2203 | 6 | 6 |
4 | 1089.48 | 41 | 12.23 | 1885 | 6 | 6 |
5 | 313.56 | 41 | 13.39 | 895 | 6 | 6 |
6 | 38.80 | 41 | 13.94 | 481 | 6 | 6 |
7 | 0.32 | 180 | 13.92 | 444 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.64 | 32 | 14.00 | 540 | 6 | 6 |
2 | 1200.92 | 81 | 9.04 | 1913 | 6 | 6 |
3 | 1146.72 | 41 | 12.06 | 1923 | 6 | 6 |
4 | 451.16 | 41 | 13.20 | 1080 | 6 | 7 |
5 | 46.60 | 41 | 13.88 | 503 | 6 | 6 |
6 | 0.40 | 40 | 14.03 | 442 | 6 | 6 |
7 | 0.28 | 181 | 13.88 | 443 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.12 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1401.40 | 81 | 5.75 | 2102 | 6 | 6 |
3 | 1449.60 | 41 | 11.20 | 2271 | 6 | 6 |
4 | 1381.72 | 41 | 11.63 | 2198 | 6 | 6 |
5 | 767.64 | 41 | 12.79 | 1453 | 6 | 6 |
6 | 79.00 | 41 | 13.82 | 565 | 6 | 6 |
7 | 7.16 | 41 | 14.04 | 427 | 6 | 6 |
8 | 0.12 | 40 | 14.11 | 425 | 6 | 6 |
9 | 0.08 | 181 | 13.97 | 437 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.48 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1401.08 | 81 | 5.98 | 2061 | 6 | 6 |
3 | 1442.64 | 41 | 11.23 | 2245 | 6 | 6 |
4 | 1365.88 | 41 | 11.65 | 2187 | 6 | 6 |
5 | 545.60 | 41 | 13.07 | 1178 | 6 | 6 |
6 | 50.44 | 41 | 13.85 | 532 | 6 | 6 |
7 | 26.80 | 41 | 14.00 | 471 | 6 | 6 |
8 | 0.32 | 40 | 14.06 | 451 | 6 | 6 |
9 | 0.20 | 181 | 13.94 | 441 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.08 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1413.76 | 81 | 6.16 | 2077 | 6 | 6 |
3 | 1440.56 | 41 | 11.14 | 2272 | 6 | 6 |
4 | 1360.16 | 41 | 11.64 | 2167 | 6 | 6 |
5 | 530.96 | 41 | 13.11 | 1151 | 6 | 6 |
6 | 50.80 | 41 | 13.88 | 510 | 6 | 6 |
7 | 0.24 | 40 | 14.04 | 445 | 6 | 6 |
8 | 0.12 | 181 | 13.94 | 441 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.52 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1411.52 | 81 | 7.34 | 2111 | 6 | 6 |
3 | 1375.48 | 41 | 11.62 | 2161 | 6 | 6 |
4 | 832.80 | 41 | 12.64 | 1538 | 6 | 6 |
5 | 99.28 | 41 | 13.76 | 597 | 6 | 6 |
6 | 31.44 | 41 | 13.97 | 470 | 6 | 6 |
7 | 0.36 | 40 | 14.04 | 446 | 6 | 6 |
8 | 0.28 | 181 | 13.95 | 435 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.36 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1199.08 | 81 | 9.03 | 1904 | 6 | 6 |
3 | 1129.36 | 41 | 12.09 | 1893 | 6 | 6 |
4 | 630.40 | 41 | 12.89 | 1310 | 6 | 6 |
5 | 61.88 | 41 | 13.80 | 556 | 6 | 6 |
6 | 32.28 | 41 | 13.95 | 487 | 6 | 6 |
7 | 0.24 | 41 | 14.02 | 460 | 6 | 6 |
8 | 0.12 | 180 | 13.89 | 444 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.12 | 32 | 13.93 | 560 | 6 | 6 |
2 | 1402.00 | 81 | 5.71 | 2095 | 6 | 6 |
3 | 1444.36 | 41 | 11.24 | 2231 | 6 | 6 |
4 | 1367.24 | 41 | 11.64 | 2193 | 6 | 6 |
5 | 563.28 | 41 | 13.04 | 1187 | 6 | 7 |
6 | 59.24 | 41 | 13.84 | 540 | 6 | 6 |
7 | 30.88 | 41 | 13.94 | 487 | 6 | 6 |
8 | 0.32 | 40 | 14.04 | 448 | 6 | 6 |
9 | 0.20 | 181 | 13.92 | 446 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.88 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1402.00 | 81 | 5.94 | 2077 | 6 | 6 |
3 | 1443.36 | 41 | 11.30 | 2216 | 6 | 6 |
4 | 1363.68 | 41 | 11.64 | 2200 | 6 | 6 |
5 | 632.28 | 41 | 12.87 | 1312 | 6 | 6 |
6 | 65.76 | 41 | 13.79 | 561 | 6 | 6 |
7 | 15.92 | 41 | 13.98 | 458 | 6 | 6 |
8 | 0.36 | 180 | 13.93 | 440 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.04 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1401.92 | 70 | 5.82 | 2073 | 6 | 6 |
3 | 1459.12 | 20 | 11.80 | 2297 | 6 | 6 |
4 | 1407.00 | 20 | 12.23 | 2237 | 6 | 6 |
5 | 1325.12 | 20 | 12.45 | 2140 | 6 | 6 |
6 | 1194.08 | 20 | 12.69 | 1982 | 6 | 6 |
7 | 771.00 | 20 | 13.07 | 1507 | 6 | 7 |
8 | 346.64 | 20 | 13.51 | 947 | 6 | 6 |
9 | 82.04 | 20 | 13.86 | 595 | 6 | 6 |
10 | 45.60 | 20 | 13.99 | 512 | 6 | 6 |
11 | 23.60 | 20 | 14.02 | 477 | 6 | 6 |
12 | 0.24 | 20 | 14.12 | 445 | 6 | 6 |
13 | 0.20 | 180 | 14.01 | 438 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.52 | 32 | 14.00 | 540 | 6 | 6 |
2 | 1415.80 | 70 | 7.13 | 2137 | 6 | 6 |
3 | 1374.56 | 20 | 12.24 | 2177 | 6 | 6 |
4 | 1277.00 | 20 | 12.46 | 2102 | 6 | 6 |
5 | 1152.56 | 20 | 12.66 | 1932 | 6 | 6 |
6 | 621.48 | 20 | 13.20 | 1307 | 6 | 6 |
7 | 356.96 | 20 | 13.50 | 970 | 6 | 6 |
8 | 59.92 | 20 | 13.91 | 560 | 6 | 6 |
9 | 39.72 | 20 | 13.99 | 497 | 6 | 6 |
10 | 21.04 | 20 | 14.09 | 457 | 6 | 6 |
11 | 0.32 | 20 | 14.12 | 432 | 6 | 6 |
12 | 0.28 | 180 | 14.03 | 440 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 32 | 14.00 | 520 | 6 | 6 |
2 | 1175.36 | 70 | 9.34 | 1851 | 6 | 6 |
3 | 1110.16 | 21 | 12.46 | 1871 | 6 | 6 |
4 | 999.00 | 21 | 12.71 | 1757 | 6 | 6 |
5 | 583.24 | 21 | 13.15 | 1248 | 6 | 6 |
6 | 87.84 | 21 | 13.85 | 577 | 6 | 6 |
7 | 55.24 | 21 | 13.96 | 515 | 6 | 6 |
8 | 35.72 | 21 | 14.03 | 486 | 6 | 6 |
9 | 0.32 | 20 | 14.09 | 447 | 6 | 6 |
10 | 0.24 | 180 | 14.02 | 428 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.16 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1402.40 | 70 | 5.79 | 2039 | 6 | 6 |
3 | 1463.76 | 20 | 11.85 | 2340 | 6 | 6 |
4 | 1403.24 | 20 | 12.20 | 2282 | 6 | 6 |
5 | 1311.04 | 20 | 12.44 | 2165 | 6 | 6 |
6 | 1189.80 | 20 | 12.68 | 1982 | 6 | 6 |
7 | 784.36 | 20 | 13.03 | 1512 | 6 | 7 |
8 | 226.72 | 20 | 13.62 | 792 | 6 | 6 |
9 | 61.64 | 20 | 13.98 | 520 | 6 | 6 |
10 | 42.48 | 20 | 14.02 | 497 | 6 | 6 |
11 | 22.52 | 20 | 14.09 | 445 | 6 | 6 |
12 | 0.36 | 20 | 14.14 | 442 | 6 | 6 |
13 | 0.28 | 180 | 14.07 | 416 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1414.92 | 70 | 5.65 | 2085 | 6 | 6 |
3 | 1485.08 | 20 | 11.79 | 2382 | 6 | 6 |
4 | 1437.72 | 20 | 12.20 | 2310 | 6 | 6 |
5 | 1330.12 | 20 | 12.38 | 2190 | 6 | 6 |
6 | 1206.36 | 20 | 12.59 | 2042 | 6 | 7 |
7 | 933.88 | 20 | 12.94 | 1687 | 6 | 6 |
8 | 350.88 | 20 | 13.54 | 927 | 6 | 6 |
9 | 70.48 | 20 | 13.95 | 525 | 6 | 6 |
10 | 49.80 | 20 | 14.02 | 507 | 6 | 6 |
11 | 27.44 | 20 | 14.08 | 477 | 6 | 6 |
12 | 0.20 | 20 | 14.15 | 452 | 6 | 6 |
13 | 0.24 | 180 | 14.08 | 437 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 32 | 13.93 | 580 | 7 | 7 |
2 | 1415.08 | 70 | 5.50 | 2096 | 6 | 6 |
3 | 1487.12 | 20 | 11.91 | 2307 | 6 | 6 |
4 | 1444.48 | 20 | 12.18 | 2325 | 6 | 6 |
5 | 1350.52 | 20 | 12.41 | 2182 | 6 | 6 |
6 | 1239.28 | 20 | 12.56 | 2075 | 6 | 6 |
7 | 823.00 | 20 | 13.02 | 1532 | 6 | 6 |
8 | 266.56 | 20 | 13.65 | 790 | 6 | 6 |
9 | 78.68 | 20 | 13.92 | 542 | 6 | 6 |
10 | 57.32 | 20 | 14.02 | 512 | 6 | 6 |
11 | 32.24 | 20 | 14.03 | 495 | 6 | 6 |
12 | 0.20 | 20 | 14.16 | 420 | 6 | 6 |
13 | 0.16 | 180 | 14.07 | 432 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.76 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1404.36 | 70 | 6.93 | 2104 | 6 | 6 |
3 | 1395.76 | 20 | 12.17 | 2225 | 6 | 6 |
4 | 1308.36 | 20 | 12.45 | 2122 | 6 | 6 |
5 | 1188.40 | 20 | 12.62 | 1995 | 6 | 7 |
6 | 643.36 | 20 | 13.25 | 1275 | 6 | 6 |
7 | 372.48 | 20 | 13.48 | 972 | 6 | 6 |
8 | 74.48 | 20 | 13.95 | 507 | 6 | 6 |
9 | 54.24 | 20 | 14.00 | 530 | 6 | 6 |
10 | 28.96 | 20 | 14.05 | 490 | 6 | 6 |
11 | 0.24 | 20 | 14.18 | 400 | 6 | 6 |
12 | 0.16 | 180 | 14.07 | 437 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.76 | 32 | 14.06 | 540 | 7 | 6 |
2 | 1187.48 | 70 | 9.21 | 1860 | 6 | 6 |
3 | 1123.92 | 21 | 12.43 | 1931 | 6 | 6 |
4 | 1011.00 | 21 | 12.65 | 1800 | 6 | 6 |
5 | 612.88 | 21 | 13.14 | 1302 | 6 | 6 |
6 | 190.36 | 21 | 13.67 | 748 | 6 | 6 |
7 | 69.12 | 21 | 13.87 | 566 | 6 | 6 |
8 | 44.68 | 21 | 14.03 | 484 | 6 | 6 |
9 | 0.24 | 20 | 14.09 | 450 | 6 | 6 |
10 | 0.12 | 180 | 14.05 | 435 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.04 | 32 | 14.06 | 560 | 7 | 6 |
2 | 1404.52 | 70 | 5.80 | 2035 | 6 | 6 |
3 | 1460.24 | 20 | 11.92 | 2257 | 6 | 6 |
4 | 1398.16 | 20 | 12.21 | 2277 | 6 | 6 |
5 | 1302.80 | 20 | 12.46 | 2155 | 6 | 6 |
6 | 1181.80 | 20 | 12.68 | 1975 | 6 | 6 |
7 | 759.68 | 20 | 13.06 | 1492 | 6 | 6 |
8 | 205.16 | 20 | 13.69 | 762 | 6 | 6 |
9 | 68.52 | 20 | 13.91 | 555 | 6 | 6 |
10 | 47.56 | 20 | 14.07 | 480 | 6 | 6 |
11 | 22.96 | 20 | 14.10 | 465 | 6 | 6 |
12 | 0.16 | 20 | 14.17 | 402 | 6 | 6 |
13 | 0.24 | 180 | 14.09 | 432 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.96 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1401.92 | 70 | 5.13 | 2149 | 6 | 6 |
3 | 1486.08 | 20 | 11.90 | 2315 | 6 | 6 |
4 | 1478.44 | 20 | 12.21 | 2352 | 6 | 6 |
5 | 1397.08 | 20 | 12.40 | 2272 | 6 | 6 |
6 | 1286.36 | 20 | 12.55 | 2140 | 6 | 6 |
7 | 1023.52 | 20 | 12.89 | 1792 | 6 | 6 |
8 | 595.44 | 20 | 13.30 | 1270 | 6 | 7 |
9 | 93.72 | 20 | 13.92 | 582 | 6 | 6 |
10 | 64.08 | 20 | 14.02 | 492 | 6 | 6 |
11 | 39.84 | 20 | 14.04 | 495 | 6 | 6 |
12 | 0.28 | 20 | 14.18 | 400 | 6 | 6 |
13 | 0.20 | 180 | 14.10 | 428 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.48 | 32 | 14.00 | 580 | 6 | 6 |
2 | 1401.52 | 70 | 5.36 | 2118 | 6 | 6 |
3 | 1481.84 | 20 | 11.93 | 2327 | 6 | 6 |
4 | 1460.20 | 20 | 12.30 | 2295 | 6 | 6 |
5 | 1363.64 | 20 | 12.43 | 2210 | 6 | 6 |
6 | 1239.36 | 20 | 12.63 | 2050 | 6 | 6 |
7 | 837.32 | 20 | 13.09 | 1535 | 6 | 6 |
8 | 408.16 | 20 | 13.46 | 1012 | 6 | 6 |
9 | 84.64 | 20 | 13.91 | 570 | 6 | 6 |
10 | 59.88 | 20 | 14.08 | 482 | 6 | 6 |
11 | 33.84 | 20 | 14.09 | 455 | 6 | 6 |
12 | 0.20 | 20 | 14.17 | 402 | 6 | 6 |
13 | 0.24 | 180 | 14.09 | 437 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.56 | 32 | 14.00 | 580 | 6 | 6 |
2 | 1403.68 | 70 | 7.18 | 2088 | 6 | 6 |
3 | 1381.40 | 20 | 12.26 | 2197 | 6 | 6 |
4 | 1292.76 | 20 | 12.53 | 2082 | 6 | 6 |
5 | 1163.64 | 20 | 12.71 | 1920 | 6 | 6 |
6 | 623.76 | 20 | 13.25 | 1265 | 6 | 6 |
7 | 349.08 | 20 | 13.55 | 920 | 6 | 6 |
8 | 92.52 | 20 | 13.91 | 552 | 6 | 6 |
9 | 60.96 | 20 | 14.04 | 497 | 6 | 6 |
10 | 30.72 | 20 | 14.09 | 472 | 6 | 6 |
11 | 0.20 | 20 | 14.08 | 495 | 6 | 6 |
12 | 0.24 | 180 | 14.03 | 452 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.76 | 32 | 14.00 | 580 | 7 | 7 |
2 | 1196.16 | 70 | 9.19 | 1894 | 7 | 6 |
3 | 1133.52 | 21 | 12.48 | 1880 | 6 | 6 |
4 | 1021.04 | 21 | 12.68 | 1800 | 6 | 6 |
5 | 503.44 | 21 | 13.20 | 1208 | 6 | 6 |
6 | 230.20 | 21 | 13.56 | 855 | 6 | 6 |
7 | 69.88 | 21 | 13.86 | 615 | 6 | 6 |
8 | 46.12 | 21 | 13.92 | 573 | 6 | 6 |
9 | 0.28 | 20 | 14.07 | 495 | 6 | 6 |
10 | 0.24 | 180 | 14.03 | 452 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.96 | 32 | 14.00 | 620 | 7 | 6 |
2 | 1407.00 | 70 | 5.86 | 2055 | 6 | 6 |
3 | 1459.00 | 20 | 11.89 | 2280 | 6 | 6 |
4 | 1387.00 | 20 | 12.24 | 2215 | 6 | 6 |
5 | 1280.52 | 20 | 12.53 | 2072 | 6 | 6 |
6 | 1024.56 | 20 | 12.88 | 1747 | 6 | 7 |
7 | 609.52 | 20 | 13.26 | 1230 | 6 | 6 |
8 | 106.24 | 20 | 13.85 | 567 | 6 | 6 |
9 | 73.48 | 20 | 14.01 | 497 | 6 | 6 |
10 | 49.28 | 20 | 14.06 | 462 | 6 | 6 |
11 | 23.68 | 20 | 14.06 | 495 | 6 | 6 |
12 | 0.16 | 20 | 14.07 | 522 | 6 | 6 |
13 | 0.12 | 180 | 14.03 | 464 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.08 | 32 | 14.06 | 580 | 7 | 6 |
2 | 1404.72 | 70 | 5.61 | 2038 | 6 | 6 |
3 | 1478.88 | 20 | 11.86 | 2310 | 6 | 6 |
4 | 1423.52 | 20 | 12.32 | 2237 | 6 | 6 |
5 | 1325.76 | 20 | 12.55 | 2105 | 6 | 6 |
6 | 1199.80 | 20 | 12.72 | 1962 | 6 | 6 |
7 | 778.88 | 20 | 13.15 | 1435 | 6 | 6 |
8 | 207.64 | 20 | 13.74 | 692 | 6 | 6 |
9 | 96.60 | 20 | 13.94 | 532 | 6 | 6 |
10 | 54.76 | 20 | 14.05 | 457 | 6 | 6 |
11 | 29.24 | 20 | 14.01 | 540 | 6 | 6 |
12 | 0.24 | 20 | 14.02 | 545 | 6 | 6 |
13 | 0.20 | 180 | 13.97 | 483 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.12 | 32 | 14.00 | 600 | 6 | 6 |
2 | 1410.92 | 70 | 5.39 | 2090 | 6 | 6 |
3 | 1489.52 | 20 | 12.04 | 2295 | 6 | 6 |
4 | 1453.52 | 20 | 12.32 | 2275 | 6 | 6 |
5 | 1361.40 | 20 | 12.51 | 2167 | 6 | 6 |
6 | 1243.40 | 20 | 12.66 | 2037 | 6 | 6 |
7 | 841.48 | 20 | 13.09 | 1527 | 6 | 6 |
8 | 281.24 | 20 | 13.67 | 785 | 6 | 6 |
9 | 92.16 | 20 | 14.00 | 510 | 6 | 6 |
10 | 62.52 | 20 | 14.08 | 455 | 6 | 6 |
11 | 35.08 | 20 | 14.16 | 420 | 6 | 6 |
12 | 0.16 | 180 | 14.08 | 455 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.16 | 32 | 14.00 | 600 | 6 | 6 |
2 | 1408.36 | 70 | 7.17 | 2132 | 6 | 6 |
3 | 1386.24 | 20 | 12.28 | 2210 | 6 | 6 |
4 | 1298.60 | 20 | 12.53 | 2115 | 6 | 6 |
5 | 1174.44 | 20 | 12.70 | 1957 | 6 | 6 |
6 | 772.12 | 20 | 13.13 | 1442 | 6 | 6 |
7 | 350.92 | 20 | 13.58 | 915 | 6 | 7 |
8 | 103.20 | 20 | 13.90 | 567 | 6 | 6 |
9 | 70.08 | 20 | 14.04 | 487 | 6 | 6 |
10 | 35.88 | 20 | 14.12 | 422 | 6 | 6 |
11 | 0.16 | 20 | 14.25 | 362 | 6 | 6 |
12 | 0.12 | 180 | 14.03 | 461 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.92 | 32 | 14.00 | 580 | 6 | 6 |
2 | 1204.36 | 70 | 9.17 | 1905 | 6 | 6 |
3 | 1136.92 | 21 | 12.45 | 1908 | 6 | 6 |
4 | 1014.80 | 21 | 12.69 | 1760 | 6 | 6 |
5 | 885.20 | 21 | 12.89 | 1588 | 6 | 6 |
6 | 289.96 | 21 | 13.58 | 833 | 6 | 6 |
7 | 84.08 | 21 | 13.80 | 655 | 6 | 6 |
8 | 50.80 | 21 | 13.91 | 602 | 6 | 6 |
9 | 0.20 | 20 | 14.08 | 520 | 6 | 6 |
10 | 0.28 | 180 | 13.99 | 470 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 32 | 14.12 | 540 | 6 | 6 |
2 | 1405.48 | 70 | 6.02 | 2054 | 6 | 6 |
3 | 1463.12 | 20 | 11.86 | 2282 | 6 | 6 |
4 | 1396.60 | 20 | 12.31 | 2217 | 6 | 6 |
5 | 1296.40 | 20 | 12.46 | 2137 | 6 | 6 |
6 | 916.32 | 20 | 12.94 | 1645 | 6 | 7 |
7 | 506.88 | 20 | 13.41 | 1100 | 6 | 6 |
8 | 113.16 | 20 | 13.84 | 600 | 6 | 6 |
9 | 78.96 | 20 | 14.00 | 520 | 6 | 6 |
10 | 47.04 | 20 | 14.05 | 487 | 6 | 6 |
11 | 0.24 | 20 | 14.19 | 387 | 6 | 6 |
12 | 0.20 | 180 | 14.02 | 470 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 32 | 14.12 | 540 | 6 | 6 |
2 | 1414.36 | 70 | 4.77 | 2216 | 6 | 6 |
3 | 1500.12 | 20 | 12.01 | 2332 | 6 | 6 |
4 | 1535.96 | 20 | 12.25 | 2410 | 6 | 6 |
5 | 1466.36 | 20 | 12.38 | 2342 | 6 | 6 |
6 | 1344.64 | 20 | 12.58 | 2180 | 6 | 6 |
7 | 1081.96 | 20 | 12.90 | 1862 | 6 | 7 |
8 | 522.00 | 20 | 13.37 | 1152 | 6 | 6 |
9 | 113.72 | 20 | 13.83 | 615 | 6 | 6 |
10 | 75.28 | 20 | 13.99 | 505 | 6 | 6 |
11 | 45.28 | 20 | 14.04 | 510 | 6 | 6 |
12 | 0.24 | 20 | 14.15 | 427 | 6 | 6 |
13 | 0.20 | 180 | 14.15 | 393 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.24 | 32 | 14.06 | 580 | 7 | 6 |
2 | 1404.08 | 70 | 5.64 | 2062 | 6 | 6 |
3 | 1482.72 | 20 | 12.09 | 2297 | 6 | 6 |
4 | 1434.96 | 20 | 12.39 | 2272 | 6 | 6 |
5 | 1342.56 | 20 | 12.51 | 2197 | 6 | 6 |
6 | 1087.36 | 20 | 12.84 | 1862 | 6 | 6 |
7 | 693.16 | 20 | 13.20 | 1367 | 6 | 6 |
8 | 135.12 | 20 | 13.78 | 640 | 6 | 6 |
9 | 74.52 | 20 | 13.98 | 540 | 6 | 6 |
10 | 46.28 | 20 | 14.00 | 512 | 6 | 6 |
11 | 8.24 | 20 | 14.12 | 435 | 6 | 6 |
12 | 0.16 | 20 | 14.18 | 427 | 6 | 6 |
13 | 0.08 | 180 | 14.06 | 426 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.76 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1402.52 | 70 | 7.26 | 2100 | 6 | 6 |
3 | 1369.84 | 20 | 12.38 | 2212 | 6 | 6 |
4 | 1289.04 | 20 | 12.58 | 2122 | 6 | 6 |
5 | 1165.40 | 20 | 12.78 | 1932 | 6 | 6 |
6 | 884.92 | 20 | 13.04 | 1607 | 6 | 7 |
7 | 290.96 | 20 | 13.64 | 847 | 6 | 6 |
8 | 76.84 | 20 | 13.96 | 527 | 6 | 6 |
9 | 51.80 | 20 | 14.02 | 530 | 6 | 6 |
10 | 26.24 | 20 | 14.09 | 457 | 6 | 6 |
11 | 0.20 | 20 | 14.16 | 425 | 6 | 6 |
12 | 0.20 | 180 | 14.06 | 426 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.12 | 32 | 14.06 | 560 | 6 | 6 |
2 | 1184.24 | 70 | 9.45 | 1882 | 6 | 6 |
3 | 1101.96 | 21 | 12.58 | 1891 | 6 | 7 |
4 | 992.88 | 21 | 12.77 | 1757 | 6 | 6 |
5 | 586.36 | 21 | 13.28 | 1228 | 6 | 6 |
6 | 158.88 | 21 | 13.73 | 695 | 6 | 6 |
7 | 53.00 | 21 | 13.90 | 566 | 6 | 6 |
8 | 31.76 | 21 | 14.00 | 542 | 6 | 6 |
9 | 0.28 | 180 | 14.01 | 457 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.48 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1406.44 | 70 | 6.22 | 2051 | 6 | 6 |
3 | 1466.84 | 20 | 12.19 | 2370 | 6 | 6 |
4 | 1399.96 | 20 | 12.48 | 2292 | 6 | 6 |
5 | 1294.60 | 20 | 12.60 | 2162 | 6 | 6 |
6 | 1039.08 | 20 | 12.94 | 1797 | 6 | 6 |
7 | 627.68 | 20 | 13.28 | 1305 | 6 | 6 |
8 | 98.08 | 20 | 13.92 | 587 | 6 | 6 |
9 | 61.20 | 20 | 14.04 | 505 | 6 | 6 |
10 | 37.44 | 20 | 14.08 | 442 | 6 | 6 |
11 | 0.28 | 20 | 14.27 | 367 | 6 | 6 |
12 | 0.20 | 180 | 14.13 | 395 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 32 | 14.06 | 580 | 6 | 6 |
2 | 1402.64 | 70 | 8.26 | 2134 | 6 | 6 |
3 | 1347.72 | 20 | 12.49 | 2220 | 6 | 6 |
4 | 1239.80 | 20 | 12.63 | 2105 | 6 | 6 |
5 | 1119.92 | 20 | 12.84 | 1932 | 6 | 6 |
6 | 673.64 | 20 | 13.23 | 1367 | 6 | 7 |
7 | 109.64 | 20 | 13.84 | 635 | 6 | 6 |
8 | 56.08 | 20 | 14.00 | 527 | 6 | 6 |
9 | 30.52 | 20 | 14.02 | 500 | 6 | 6 |
10 | 14.68 | 20 | 14.04 | 495 | 6 | 6 |
11 | 0.28 | 180 | 14.01 | 427 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.40 | 32 | 14.00 | 560 | 6 | 6 |
2 | 1179.60 | 70 | 10.73 | 1925 | 6 | 6 |
3 | 1090.00 | 21 | 12.72 | 1915 | 6 | 6 |
4 | 960.72 | 21 | 12.87 | 1753 | 6 | 6 |
5 | 389.52 | 21 | 13.46 | 1031 | 6 | 6 |
6 | 66.84 | 21 | 13.96 | 531 | 6 | 6 |
7 | 41.56 | 21 | 14.01 | 502 | 6 | 6 |
8 | 20.60 | 21 | 14.04 | 506 | 6 | 6 |
9 | 0.24 | 20 | 14.18 | 407 | 6 | 6 |
10 | 0.24 | 180 | 13.98 | 451 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.68 | 32 | 13.93 | 620 | 6 | 6 |
2 | 1416.80 | 70 | 7.45 | 2122 | 6 | 6 |
3 | 1373.64 | 20 | 12.48 | 2190 | 6 | 6 |
4 | 1271.88 | 20 | 12.60 | 2140 | 6 | 6 |
5 | 1022.64 | 20 | 12.86 | 1820 | 6 | 6 |
6 | 626.44 | 20 | 13.27 | 1335 | 6 | 6 |
7 | 113.60 | 20 | 13.83 | 660 | 6 | 6 |
8 | 66.32 | 20 | 13.99 | 532 | 6 | 6 |
9 | 39.56 | 20 | 13.98 | 527 | 6 | 6 |
10 | 0.32 | 20 | 14.12 | 480 | 6 | 6 |
11 | 0.20 | 180 | 14.00 | 451 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.72 | 32 | 14.06 | 580 | 7 | 7 |
2 | 1402.80 | 70 | 8.30 | 2110 | 6 | 6 |
3 | 1339.56 | 20 | 12.49 | 2232 | 6 | 6 |
4 | 1232.88 | 20 | 12.67 | 2065 | 6 | 6 |
5 | 973.08 | 20 | 12.89 | 1785 | 6 | 7 |
6 | 565.88 | 21 | 13.30 | 1211 | 6 | 6 |
7 | 84.12 | 20 | 13.86 | 612 | 6 | 6 |
8 | 60.16 | 20 | 14.05 | 502 | 6 | 6 |
9 | 33.28 | 20 | 14.10 | 472 | 6 | 6 |
10 | 0.24 | 20 | 14.14 | 475 | 6 | 6 |
11 | 0.20 | 180 | 14.03 | 450 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 32 | 14.06 | 580 | 6 | 6 |
2 | 1183.76 | 70 | 10.71 | 1972 | 6 | 6 |
3 | 1092.96 | 21 | 12.73 | 1948 | 6 | 6 |
4 | 839.12 | 21 | 12.94 | 1648 | 6 | 7 |
5 | 425.88 | 21 | 13.39 | 1106 | 6 | 6 |
6 | 85.12 | 21 | 13.91 | 608 | 6 | 6 |
7 | 55.44 | 21 | 13.94 | 591 | 6 | 6 |
8 | 0.48 | 20 | 14.12 | 502 | 6 | 6 |
9 | 0.52 | 180 | 14.00 | 459 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.12 | 32 | 14.06 | 580 | 6 | 6 |
2 | 1403.28 | 70 | 7.43 | 2097 | 6 | 6 |
3 | 1373.40 | 20 | 12.44 | 2195 | 6 | 6 |
4 | 1279.28 | 20 | 12.64 | 2087 | 6 | 6 |
5 | 1157.52 | 20 | 12.81 | 1955 | 6 | 6 |
6 | 736.84 | 20 | 13.20 | 1460 | 6 | 6 |
7 | 299.28 | 20 | 13.58 | 932 | 6 | 6 |
8 | 81.16 | 20 | 13.89 | 615 | 6 | 6 |
9 | 57.16 | 20 | 14.04 | 517 | 6 | 6 |
10 | 0.28 | 20 | 14.12 | 487 | 6 | 6 |
11 | 0.20 | 180 | 14.00 | 468 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.52 | 32 | 14.00 | 600 | 6 | 6 |
2 | 1403.48 | 70 | 8.13 | 2129 | 6 | 6 |
3 | 1348.96 | 20 | 12.61 | 2142 | 6 | 6 |
4 | 1240.96 | 20 | 12.77 | 2047 | 6 | 6 |
5 | 1113.32 | 20 | 12.83 | 1907 | 6 | 6 |
6 | 684.24 | 20 | 13.26 | 1417 | 6 | 6 |
7 | 117.88 | 20 | 13.82 | 645 | 6 | 6 |
8 | 77.96 | 20 | 13.92 | 612 | 6 | 6 |
9 | 45.40 | 20 | 14.05 | 542 | 6 | 6 |
10 | 0.20 | 20 | 14.15 | 480 | 6 | 6 |
11 | 0.16 | 180 | 14.02 | 466 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.40 | 32 | 14.00 | 620 | 6 | 6 |
2 | 1185.88 | 70 | 10.86 | 1939 | 6 | 6 |
3 | 1098.00 | 21 | 12.67 | 2002 | 6 | 6 |
4 | 970.08 | 21 | 12.80 | 1840 | 6 | 6 |
5 | 547.64 | 21 | 13.22 | 1295 | 6 | 6 |
6 | 105.72 | 21 | 13.77 | 706 | 6 | 6 |
7 | 64.32 | 21 | 13.89 | 642 | 6 | 6 |
8 | 33.40 | 21 | 14.01 | 571 | 6 | 6 |
9 | 0.28 | 180 | 13.98 | 478 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.80 | 32 | 14.00 | 640 | 6 | 6 |
2 | 1404.36 | 70 | 7.16 | 2092 | 6 | 6 |
3 | 1380.72 | 20 | 12.38 | 2207 | 6 | 6 |
4 | 1287.00 | 20 | 12.66 | 2075 | 6 | 6 |
5 | 1167.12 | 20 | 12.77 | 1940 | 6 | 6 |
6 | 904.04 | 20 | 13.01 | 1625 | 6 | 6 |
7 | 336.68 | 20 | 13.56 | 890 | 6 | 6 |
8 | 92.92 | 20 | 13.87 | 597 | 6 | 6 |
9 | 57.40 | 20 | 13.91 | 622 | 6 | 6 |
10 | 32.36 | 20 | 13.96 | 592 | 6 | 6 |
11 | 0.28 | 20 | 14.09 | 527 | 6 | 6 |
12 | 0.20 | 180 | 13.94 | 485 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.52 | 32 | 13.93 | 660 | 6 | 6 |
2 | 1401.24 | 70 | 7.11 | 2080 | 6 | 6 |
3 | 1381.16 | 20 | 12.40 | 2205 | 6 | 6 |
4 | 1301.44 | 20 | 12.66 | 2097 | 6 | 6 |
5 | 1172.40 | 20 | 12.77 | 1957 | 6 | 6 |
6 | 907.44 | 20 | 13.05 | 1630 | 6 | 6 |
7 | 204.20 | 20 | 13.73 | 715 | 6 | 6 |
8 | 93.16 | 20 | 13.95 | 567 | 6 | 6 |
9 | 62.92 | 20 | 14.02 | 507 | 6 | 6 |
10 | 31.88 | 20 | 14.14 | 442 | 6 | 6 |
11 | 0.20 | 20 | 14.24 | 400 | 6 | 6 |
12 | 0.20 | 180 | 13.94 | 493 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.08 | 31 | 14.12 | 500 | 7 | 6 |
2 | 1196.36 | 70 | 10.27 | 1918 | 6 | 6 |
3 | 1111.96 | 21 | 12.76 | 1868 | 6 | 6 |
4 | 865.76 | 21 | 13.01 | 1597 | 6 | 7 |
5 | 583.04 | 21 | 13.25 | 1237 | 6 | 6 |
6 | 89.92 | 21 | 13.91 | 577 | 6 | 6 |
7 | 63.16 | 21 | 14.04 | 526 | 6 | 6 |
8 | 32.28 | 21 | 14.12 | 460 | 6 | 6 |
9 | 0.24 | 20 | 14.22 | 417 | 6 | 6 |
10 | 0.24 | 180 | 13.97 | 473 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.40 | 32 | 14.12 | 520 | 6 | 6 |
2 | 1416.56 | 70 | 4.48 | 1352 | 6 | 7 |
3 | 1607.76 | 20 | 9.93 | 2445 | 6 | 6 |
4 | 1652.84 | 20 | 12.28 | 2522 | 6 | 6 |
5 | 1592.76 | 20 | 12.49 | 2470 | 6 | 6 |
6 | 1490.36 | 20 | 12.62 | 2352 | 6 | 6 |
7 | 1365.84 | 20 | 12.77 | 2175 | 6 | 6 |
8 | 679.84 | 20 | 13.27 | 1342 | 6 | 6 |
9 | 262.12 | 20 | 13.70 | 817 | 6 | 6 |
10 | 80.08 | 20 | 13.91 | 560 | 6 | 6 |
11 | 53.16 | 20 | 14.05 | 530 | 6 | 6 |
12 | 27.20 | 20 | 14.13 | 462 | 6 | 6 |
13 | 0.20 | 20 | 14.17 | 422 | 6 | 6 |
14 | 0.20 | 180 | 14.06 | 386 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 31 | 14.12 | 500 | 6 | 6 |
2 | 1971.48 | 21 | 4.57 | 1311 | 6 | 7 |
3 | 2047.24 | 21 | 6.03 | 2824 | 6 | 7 |
4 | 2026.84 | 21 | 11.67 | 2942 | 6 | 6 |
5 | 1943.88 | 20 | 12.10 | 2852 | 6 | 6 |
6 | 1834.76 | 20 | 12.19 | 2767 | 6 | 6 |
7 | 1704.72 | 20 | 12.42 | 2572 | 6 | 6 |
8 | 1162.76 | 20 | 12.85 | 1945 | 6 | 7 |
9 | 754.16 | 20 | 13.13 | 1455 | 6 | 6 |
10 | 200.28 | 20 | 13.82 | 702 | 6 | 6 |
11 | 92.40 | 20 | 13.95 | 577 | 6 | 6 |
12 | 56.32 | 20 | 14.08 | 515 | 6 | 6 |
13 | 27.40 | 20 | 14.12 | 472 | 6 | 6 |
14 | 0.20 | 20 | 14.20 | 427 | 6 | 6 |
15 | 0.16 | 180 | 14.08 | 383 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.92 | 30 | 14.18 | 500 | 7 | 6 |
2 | 1063.76 | 1 | 10.32 | 1780 | 6 | 6 |
3 | 1227.24 | 21 | 10.50 | 1961 | 6 | 6 |
4 | 1306.44 | 21 | 12.44 | 2102 | 6 | 6 |
5 | 1249.00 | 21 | 12.63 | 2037 | 6 | 6 |
6 | 1152.40 | 21 | 12.78 | 1911 | 6 | 6 |
7 | 1026.08 | 21 | 12.92 | 1757 | 6 | 6 |
8 | 453.20 | 21 | 13.46 | 1028 | 6 | 6 |
9 | 94.16 | 21 | 13.91 | 568 | 6 | 6 |
10 | 62.92 | 21 | 14.03 | 508 | 6 | 6 |
11 | 32.28 | 21 | 14.09 | 471 | 6 | 6 |
12 | 0.20 | 20 | 14.20 | 415 | 6 | 6 |
13 | 0.24 | 180 | 14.08 | 379 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1971.36 | 21 | 4.50 | 1215 | 6 | 7 |
3 | 2040.96 | 20 | 4.90 | 2312 | 6 | 7 |
4 | 2059.56 | 20 | 9.25 | 2970 | 6 | 6 |
5 | 2004.52 | 20 | 11.70 | 2945 | 6 | 6 |
6 | 1918.24 | 20 | 12.15 | 2835 | 6 | 6 |
7 | 1803.08 | 20 | 12.31 | 2720 | 6 | 6 |
8 | 1392.48 | 20 | 12.73 | 2215 | 6 | 6 |
9 | 853.16 | 20 | 13.14 | 1567 | 6 | 7 |
10 | 444.64 | 20 | 13.47 | 1050 | 6 | 6 |
11 | 96.76 | 20 | 13.91 | 555 | 6 | 6 |
12 | 61.44 | 20 | 14.06 | 525 | 6 | 6 |
13 | 36.56 | 20 | 14.12 | 472 | 6 | 6 |
14 | 0.24 | 181 | 14.08 | 386 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.16 | 28 | 14.12 | 500 | 6 | 6 |
2 | 1130.40 | 3 | 11.75 | 1880 | 6 | 6 |
3 | 1975.72 | 21 | 4.57 | 1351 | 6 | 7 |
4 | 2034.68 | 21 | 6.53 | 2977 | 6 | 6 |
5 | 1997.00 | 21 | 11.77 | 2935 | 6 | 6 |
6 | 1909.80 | 21 | 12.03 | 2855 | 6 | 6 |
7 | 1799.24 | 21 | 12.22 | 2700 | 6 | 6 |
8 | 1410.80 | 21 | 12.53 | 2284 | 6 | 6 |
9 | 1132.08 | 21 | 12.82 | 1911 | 6 | 7 |
10 | 425.96 | 21 | 13.47 | 1015 | 6 | 6 |
11 | 91.92 | 20 | 13.99 | 555 | 6 | 6 |
12 | 66.16 | 20 | 14.08 | 522 | 6 | 6 |
13 | 31.40 | 20 | 14.21 | 455 | 6 | 6 |
14 | 0.24 | 20 | 14.21 | 417 | 6 | 6 |
15 | 0.16 | 180 | 14.09 | 391 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.64 | 27 | 14.18 | 520 | 6 | 6 |
2 | 1101.72 | 2 | 11.50 | 1840 | 6 | 6 |
3 | 1100.12 | 21 | 11.31 | 1840 | 6 | 6 |
4 | 1006.56 | 21 | 12.79 | 1760 | 6 | 6 |
5 | 903.12 | 21 | 12.95 | 1624 | 6 | 6 |
6 | 348.36 | 20 | 13.58 | 892 | 6 | 6 |
7 | 99.76 | 20 | 13.89 | 585 | 6 | 6 |
8 | 66.44 | 20 | 14.03 | 525 | 6 | 6 |
9 | 34.76 | 20 | 14.07 | 495 | 6 | 6 |
10 | 0.28 | 20 | 14.15 | 430 | 6 | 6 |
11 | 0.20 | 180 | 14.01 | 401 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.40 | 32 | 14.12 | 520 | 6 | 7 |
2 | 1972.00 | 21 | 4.50 | 1124 | 7 | 7 |
3 | 2044.56 | 20 | 4.69 | 2060 | 6 | 7 |
4 | 2058.80 | 20 | 8.08 | 2940 | 6 | 6 |
5 | 2006.44 | 20 | 11.79 | 2965 | 6 | 6 |
6 | 1918.56 | 20 | 12.26 | 2847 | 6 | 6 |
7 | 1803.12 | 20 | 12.36 | 2735 | 6 | 6 |
8 | 1540.04 | 20 | 12.74 | 2380 | 6 | 6 |
9 | 1107.04 | 20 | 13.02 | 1897 | 6 | 6 |
10 | 545.88 | 20 | 13.46 | 1167 | 6 | 6 |
11 | 124.16 | 20 | 13.90 | 592 | 6 | 6 |
12 | 76.76 | 20 | 14.06 | 545 | 6 | 6 |
13 | 43.92 | 20 | 14.12 | 487 | 6 | 6 |
14 | 0.16 | 20 | 14.23 | 417 | 6 | 6 |
15 | 0.24 | 180 | 14.04 | 400 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.40 | 32 | 14.12 | 520 | 6 | 6 |
2 | 1971.52 | 21 | 4.57 | 1388 | 6 | 7 |
3 | 2043.56 | 20 | 8.47 | 2905 | 6 | 6 |
4 | 2003.96 | 20 | 11.96 | 2960 | 6 | 6 |
5 | 1932.68 | 20 | 12.18 | 2867 | 6 | 6 |
6 | 1830.36 | 20 | 12.35 | 2727 | 6 | 6 |
7 | 1433.36 | 20 | 12.63 | 2280 | 6 | 6 |
8 | 1020.24 | 20 | 13.06 | 1772 | 6 | 6 |
9 | 611.60 | 20 | 13.41 | 1245 | 6 | 7 |
10 | 104.76 | 20 | 13.99 | 550 | 6 | 6 |
11 | 81.40 | 20 | 14.11 | 530 | 6 | 6 |
12 | 40.68 | 20 | 14.17 | 470 | 6 | 6 |
13 | 1.12 | 181 | 14.12 | 399 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.44 | 32 | 14.06 | 540 | 6 | 6 |
2 | 1974.52 | 21 | 4.57 | 1514 | 6 | 7 |
3 | 2019.64 | 20 | 10.00 | 2927 | 6 | 6 |
4 | 1964.52 | 20 | 12.06 | 2892 | 6 | 6 |
5 | 1867.24 | 20 | 12.21 | 2807 | 6 | 6 |
6 | 1744.72 | 20 | 12.33 | 2682 | 6 | 6 |
7 | 1472.92 | 20 | 12.62 | 2327 | 6 | 6 |
8 | 1054.00 | 20 | 12.95 | 1817 | 6 | 6 |
9 | 354.64 | 20 | 13.59 | 937 | 6 | 6 |
10 | 117.08 | 20 | 14.00 | 582 | 6 | 6 |
11 | 77.76 | 20 | 14.05 | 545 | 6 | 6 |
12 | 38.20 | 20 | 14.15 | 465 | 6 | 6 |
13 | 0.16 | 20 | 14.24 | 405 | 6 | 6 |
14 | 0.16 | 180 | 14.10 | 391 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.56 | 31 | 14.18 | 520 | 6 | 6 |
2 | 1974.96 | 21 | 4.61 | 1660 | 6 | 7 |
3 | 2012.88 | 21 | 10.78 | 2935 | 6 | 6 |
4 | 1949.76 | 20 | 12.14 | 2880 | 6 | 6 |
5 | 1844.84 | 21 | 12.16 | 2795 | 6 | 6 |
6 | 1718.32 | 20 | 12.38 | 2637 | 6 | 6 |
7 | 1186.92 | 20 | 12.87 | 1982 | 6 | 6 |
8 | 776.56 | 20 | 13.22 | 1470 | 6 | 6 |
9 | 219.16 | 20 | 13.79 | 740 | 6 | 6 |
10 | 101.08 | 20 | 13.98 | 580 | 6 | 6 |
11 | 63.28 | 20 | 14.05 | 522 | 6 | 6 |
12 | 29.68 | 20 | 14.13 | 467 | 6 | 6 |
13 | 0.16 | 20 | 14.23 | 407 | 6 | 6 |
14 | 0.12 | 180 | 14.06 | 399 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 31 | 14.06 | 540 | 6 | 6 |
2 | 1974.08 | 21 | 4.59 | 1543 | 6 | 7 |
3 | 2020.24 | 21 | 10.21 | 2942 | 6 | 6 |
4 | 1957.48 | 20 | 12.03 | 2927 | 6 | 6 |
5 | 1848.20 | 20 | 12.30 | 2752 | 6 | 6 |
6 | 1720.52 | 20 | 12.41 | 2615 | 6 | 6 |
7 | 1316.72 | 20 | 12.79 | 2112 | 6 | 6 |
8 | 768.84 | 20 | 13.22 | 1442 | 6 | 7 |
9 | 348.92 | 20 | 13.66 | 900 | 6 | 6 |
10 | 96.36 | 20 | 14.00 | 560 | 6 | 6 |
11 | 58.36 | 20 | 14.07 | 505 | 6 | 6 |
12 | 30.20 | 20 | 14.15 | 447 | 6 | 6 |
13 | 0.20 | 20 | 14.21 | 417 | 6 | 6 |
14 | 0.20 | 180 | 14.05 | 397 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 31 | 14.12 | 540 | 6 | 6 |
2 | 1971.72 | 21 | 4.60 | 1580 | 6 | 7 |
3 | 2011.04 | 20 | 10.79 | 2947 | 6 | 6 |
4 | 1945.56 | 21 | 11.99 | 2906 | 6 | 6 |
5 | 1834.28 | 21 | 12.20 | 2746 | 6 | 6 |
6 | 1591.36 | 20 | 12.52 | 2470 | 6 | 6 |
7 | 1189.84 | 21 | 12.77 | 2000 | 6 | 6 |
8 | 786.80 | 21 | 13.18 | 1475 | 6 | 6 |
9 | 206.00 | 20 | 13.78 | 715 | 6 | 6 |
10 | 60.28 | 20 | 14.07 | 507 | 6 | 6 |
11 | 36.84 | 21 | 14.10 | 473 | 6 | 6 |
12 | 0.88 | 181 | 14.02 | 404 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.32 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2007.12 | 24 | 4.61 | 1669 | 6 | 7 |
3 | 2040.28 | 20 | 11.15 | 2965 | 6 | 6 |
4 | 1988.72 | 20 | 12.10 | 2922 | 6 | 6 |
5 | 1901.56 | 20 | 12.27 | 2815 | 6 | 6 |
6 | 1704.84 | 20 | 12.48 | 2582 | 6 | 6 |
7 | 1301.12 | 20 | 12.79 | 2110 | 6 | 6 |
8 | 798.92 | 20 | 13.23 | 1477 | 6 | 6 |
9 | 365.04 | 21 | 13.58 | 928 | 6 | 6 |
10 | 73.20 | 20 | 14.00 | 517 | 6 | 6 |
11 | 52.08 | 20 | 14.08 | 490 | 6 | 6 |
12 | 10.16 | 21 | 14.19 | 417 | 6 | 6 |
13 | 0.16 | 20 | 14.19 | 407 | 6 | 6 |
14 | 0.08 | 200 | 14.01 | 394 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.68 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2001.64 | 24 | 4.63 | 1758 | 6 | 7 |
3 | 2022.76 | 20 | 11.64 | 2940 | 6 | 6 |
4 | 1973.76 | 20 | 12.05 | 2927 | 6 | 6 |
5 | 1895.84 | 20 | 12.28 | 2807 | 6 | 6 |
6 | 1797.52 | 20 | 12.36 | 2712 | 6 | 6 |
7 | 1279.40 | 20 | 12.79 | 2095 | 6 | 6 |
8 | 852.24 | 20 | 13.16 | 1547 | 6 | 7 |
9 | 423.08 | 20 | 13.56 | 1020 | 6 | 6 |
10 | 83.84 | 20 | 13.99 | 545 | 6 | 6 |
11 | 54.72 | 20 | 14.07 | 505 | 6 | 6 |
12 | 26.48 | 20 | 14.12 | 457 | 6 | 6 |
13 | 0.16 | 20 | 14.19 | 420 | 6 | 6 |
14 | 0.12 | 201 | 13.99 | 404 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.72 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2007.12 | 24 | 4.65 | 1893 | 6 | 7 |
3 | 2038.76 | 20 | 11.70 | 3025 | 6 | 6 |
4 | 1994.00 | 20 | 12.08 | 2952 | 6 | 6 |
5 | 1919.72 | 20 | 12.23 | 2862 | 6 | 6 |
6 | 1826.72 | 20 | 12.35 | 2735 | 6 | 6 |
7 | 1411.20 | 20 | 12.69 | 2255 | 6 | 6 |
8 | 981.08 | 20 | 13.07 | 1730 | 6 | 7 |
9 | 436.88 | 20 | 13.52 | 1030 | 6 | 6 |
10 | 101.68 | 20 | 13.95 | 567 | 6 | 6 |
11 | 67.48 | 20 | 14.06 | 520 | 6 | 6 |
12 | 33.12 | 20 | 14.14 | 457 | 6 | 6 |
13 | 0.16 | 20 | 14.24 | 412 | 6 | 6 |
14 | 0.16 | 201 | 14.03 | 400 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2003.56 | 24 | 4.70 | 2064 | 6 | 7 |
3 | 2030.40 | 20 | 11.96 | 2980 | 6 | 6 |
4 | 1978.12 | 20 | 12.17 | 2915 | 6 | 6 |
5 | 1890.56 | 20 | 12.27 | 2815 | 6 | 6 |
6 | 1696.48 | 20 | 12.52 | 2562 | 6 | 6 |
7 | 1496.68 | 20 | 12.67 | 2325 | 6 | 6 |
8 | 962.52 | 20 | 13.05 | 1705 | 6 | 6 |
9 | 416.36 | 20 | 13.56 | 995 | 6 | 6 |
10 | 83.76 | 20 | 14.00 | 547 | 6 | 6 |
11 | 57.52 | 20 | 14.08 | 502 | 6 | 6 |
12 | 0.28 | 20 | 14.24 | 410 | 6 | 6 |
13 | 0.24 | 201 | 14.02 | 397 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2002.96 | 24 | 4.75 | 2316 | 6 | 6 |
3 | 2031.80 | 20 | 11.98 | 3007 | 6 | 6 |
4 | 1977.64 | 20 | 12.18 | 2915 | 6 | 6 |
5 | 1891.40 | 20 | 12.30 | 2802 | 6 | 6 |
6 | 1701.60 | 20 | 12.42 | 2607 | 6 | 6 |
7 | 1287.28 | 20 | 12.80 | 2095 | 6 | 6 |
8 | 762.36 | 20 | 13.24 | 1447 | 6 | 6 |
9 | 443.96 | 20 | 13.54 | 1037 | 6 | 6 |
10 | 70.84 | 20 | 14.02 | 517 | 6 | 6 |
11 | 47.60 | 20 | 14.12 | 490 | 6 | 6 |
12 | 8.40 | 20 | 14.18 | 425 | 6 | 6 |
13 | 0.12 | 20 | 14.22 | 412 | 6 | 6 |
14 | 0.12 | 201 | 14.04 | 397 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2003.76 | 24 | 5.84 | 2366 | 6 | 6 |
3 | 2015.52 | 20 | 12.02 | 2960 | 6 | 6 |
4 | 1960.96 | 20 | 12.17 | 2897 | 6 | 6 |
5 | 1881.88 | 20 | 12.25 | 2807 | 6 | 6 |
6 | 1584.40 | 20 | 12.56 | 2447 | 6 | 6 |
7 | 1165.80 | 20 | 12.91 | 1950 | 6 | 7 |
8 | 651.36 | 20 | 13.35 | 1292 | 6 | 6 |
9 | 230.64 | 20 | 13.78 | 745 | 6 | 6 |
10 | 63.96 | 20 | 14.07 | 505 | 6 | 6 |
11 | 43.64 | 20 | 14.12 | 472 | 6 | 6 |
12 | 0.24 | 20 | 14.21 | 412 | 6 | 6 |
13 | 0.24 | 201 | 14.02 | 391 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.88 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2004.60 | 24 | 6.93 | 2421 | 6 | 6 |
3 | 1989.32 | 20 | 12.05 | 2922 | 6 | 6 |
4 | 1927.64 | 20 | 12.20 | 2847 | 6 | 6 |
5 | 1840.76 | 20 | 12.30 | 2742 | 6 | 6 |
6 | 1542.24 | 20 | 12.58 | 2392 | 6 | 6 |
7 | 1128.52 | 20 | 12.94 | 1897 | 6 | 6 |
8 | 604.68 | 20 | 13.37 | 1252 | 6 | 6 |
9 | 183.92 | 20 | 13.85 | 677 | 6 | 6 |
10 | 57.20 | 20 | 14.07 | 500 | 6 | 6 |
11 | 31.44 | 20 | 14.12 | 462 | 6 | 6 |
12 | 15.32 | 20 | 14.15 | 425 | 6 | 6 |
13 | 0.12 | 200 | 14.02 | 394 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.84 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2001.96 | 24 | 7.27 | 2503 | 6 | 6 |
3 | 1975.00 | 21 | 11.95 | 2928 | 6 | 6 |
4 | 1905.44 | 21 | 12.15 | 2804 | 6 | 6 |
5 | 1811.60 | 21 | 12.26 | 2706 | 6 | 6 |
6 | 1504.00 | 21 | 12.53 | 2360 | 6 | 6 |
7 | 967.68 | 21 | 13.01 | 1691 | 6 | 6 |
8 | 527.56 | 21 | 13.41 | 1137 | 6 | 6 |
9 | 79.88 | 20 | 14.02 | 535 | 6 | 6 |
10 | 54.80 | 21 | 14.07 | 491 | 6 | 6 |
11 | 27.76 | 20 | 14.13 | 445 | 6 | 6 |
12 | 0.24 | 20 | 14.23 | 407 | 6 | 6 |
13 | 0.12 | 201 | 13.98 | 395 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.96 | 31 | 14.12 | 540 | 6 | 6 |
2 | 2005.28 | 24 | 7.26 | 2589 | 6 | 6 |
3 | 1975.76 | 20 | 12.03 | 2930 | 6 | 6 |
4 | 1908.52 | 20 | 12.15 | 2847 | 6 | 6 |
5 | 1815.36 | 20 | 12.31 | 2722 | 6 | 6 |
6 | 1505.92 | 20 | 12.62 | 2362 | 6 | 6 |
7 | 1085.92 | 20 | 12.91 | 1862 | 6 | 6 |
8 | 565.36 | 20 | 13.41 | 1195 | 6 | 6 |
9 | 126.48 | 20 | 13.90 | 612 | 6 | 6 |
10 | 58.56 | 20 | 14.02 | 515 | 6 | 6 |
11 | 33.88 | 20 | 14.09 | 470 | 6 | 6 |
12 | 0.20 | 200 | 13.98 | 403 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.32 | 31 | 14.06 | 540 | 6 | 6 |
2 | 2001.88 | 24 | 7.49 | 2656 | 6 | 6 |
3 | 1966.76 | 20 | 12.14 | 2877 | 6 | 6 |
4 | 1898.20 | 20 | 12.17 | 2840 | 6 | 6 |
5 | 1809.08 | 20 | 12.29 | 2717 | 6 | 6 |
6 | 1614.64 | 20 | 12.47 | 2510 | 6 | 6 |
7 | 1282.40 | 20 | 12.77 | 2105 | 6 | 7 |
8 | 610.28 | 20 | 13.37 | 1237 | 6 | 6 |
9 | 85.72 | 20 | 13.98 | 540 | 6 | 6 |
10 | 47.28 | 20 | 14.06 | 495 | 6 | 6 |
11 | 26.16 | 20 | 14.08 | 455 | 6 | 6 |
12 | 0.32 | 20 | 14.16 | 415 | 7 | 6 |
13 | 0.12 | 201 | 13.95 | 399 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.08 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2003.76 | 24 | 7.71 | 2692 | 6 | 6 |
3 | 1968.12 | 20 | 12.10 | 2910 | 6 | 6 |
4 | 1898.52 | 20 | 12.20 | 2825 | 6 | 6 |
5 | 1809.56 | 20 | 12.26 | 2737 | 6 | 6 |
6 | 1305.40 | 20 | 12.72 | 2135 | 6 | 6 |
7 | 907.68 | 20 | 13.09 | 1627 | 6 | 6 |
8 | 395.44 | 20 | 13.55 | 977 | 6 | 6 |
9 | 54.20 | 20 | 14.07 | 497 | 6 | 6 |
10 | 35.84 | 20 | 14.09 | 472 | 6 | 6 |
11 | 20.72 | 20 | 14.09 | 455 | 6 | 6 |
12 | 0.20 | 20 | 14.21 | 420 | 6 | 6 |
13 | 0.12 | 201 | 13.95 | 402 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.68 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2005.32 | 24 | 8.04 | 2687 | 6 | 6 |
3 | 1962.48 | 20 | 12.10 | 2915 | 6 | 6 |
4 | 1885.44 | 20 | 12.17 | 2835 | 6 | 6 |
5 | 1791.60 | 20 | 12.35 | 2697 | 6 | 6 |
6 | 1482.88 | 20 | 12.63 | 2322 | 6 | 6 |
7 | 1065.64 | 20 | 12.97 | 1820 | 6 | 6 |
8 | 515.96 | 20 | 13.46 | 1122 | 6 | 6 |
9 | 80.44 | 20 | 13.99 | 525 | 6 | 6 |
10 | 44.04 | 20 | 14.09 | 472 | 6 | 6 |
11 | 20.96 | 20 | 14.09 | 445 | 6 | 6 |
12 | 0.12 | 20 | 14.19 | 415 | 6 | 6 |
13 | 0.08 | 201 | 13.94 | 397 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.32 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2001.08 | 24 | 8.19 | 2721 | 6 | 6 |
3 | 1956.56 | 21 | 12.03 | 2891 | 6 | 6 |
4 | 1881.52 | 21 | 12.15 | 2802 | 6 | 6 |
5 | 1787.40 | 21 | 12.22 | 2713 | 6 | 6 |
6 | 1374.96 | 21 | 12.61 | 2217 | 6 | 6 |
7 | 933.20 | 21 | 13.01 | 1668 | 6 | 6 |
8 | 266.48 | 21 | 13.72 | 800 | 6 | 6 |
9 | 43.08 | 21 | 14.09 | 493 | 6 | 6 |
10 | 28.00 | 21 | 14.08 | 471 | 6 | 6 |
11 | 13.00 | 21 | 14.06 | 444 | 6 | 6 |
12 | 0.20 | 20 | 14.10 | 430 | 6 | 6 |
13 | 0.12 | 201 | 13.89 | 409 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.52 | 31 | 14.18 | 500 | 6 | 6 |
2 | 2004.12 | 24 | 8.15 | 2695 | 6 | 6 |
3 | 1968.64 | 20 | 12.13 | 2887 | 6 | 6 |
4 | 1903.52 | 20 | 12.19 | 2852 | 6 | 6 |
5 | 1813.76 | 20 | 12.31 | 2735 | 6 | 6 |
6 | 1508.28 | 20 | 12.52 | 2397 | 6 | 6 |
7 | 1078.24 | 20 | 12.97 | 1837 | 6 | 6 |
8 | 430.24 | 20 | 13.56 | 1010 | 6 | 6 |
9 | 68.04 | 20 | 14.04 | 525 | 6 | 6 |
10 | 51.32 | 20 | 14.08 | 497 | 6 | 6 |
11 | 24.40 | 20 | 14.12 | 457 | 6 | 6 |
12 | 0.28 | 20 | 14.21 | 417 | 6 | 6 |
13 | 0.28 | 201 | 13.98 | 402 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.64 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2002.48 | 24 | 8.70 | 2761 | 6 | 6 |
3 | 1956.36 | 20 | 12.12 | 2907 | 6 | 6 |
4 | 1881.68 | 20 | 12.25 | 2802 | 6 | 6 |
5 | 1788.88 | 20 | 12.32 | 2712 | 6 | 6 |
6 | 1384.32 | 20 | 12.70 | 2212 | 6 | 6 |
7 | 868.84 | 20 | 13.13 | 1585 | 6 | 6 |
8 | 444.24 | 20 | 13.53 | 1027 | 6 | 6 |
9 | 70.80 | 20 | 14.04 | 522 | 6 | 6 |
10 | 48.80 | 20 | 14.10 | 485 | 6 | 6 |
11 | 26.12 | 20 | 14.12 | 455 | 6 | 6 |
12 | 0.52 | 20 | 14.23 | 410 | 6 | 6 |
13 | 0.04 | 201 | 13.99 | 401 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.40 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2002.00 | 24 | 8.73 | 2824 | 6 | 6 |
3 | 1953.04 | 20 | 12.09 | 2905 | 6 | 6 |
4 | 1880.72 | 20 | 12.28 | 2785 | 6 | 6 |
5 | 1791.16 | 20 | 12.35 | 2682 | 6 | 6 |
6 | 1281.40 | 20 | 12.76 | 2102 | 6 | 6 |
7 | 875.32 | 20 | 13.14 | 1582 | 6 | 6 |
8 | 350.80 | 20 | 13.66 | 930 | 6 | 6 |
9 | 70.12 | 20 | 14.02 | 520 | 6 | 6 |
10 | 48.88 | 20 | 14.06 | 490 | 6 | 6 |
11 | 29.92 | 20 | 14.12 | 465 | 6 | 6 |
12 | 15.24 | 20 | 14.12 | 437 | 6 | 6 |
13 | 0.08 | 200 | 13.98 | 404 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.52 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2002.60 | 24 | 9.00 | 2736 | 6 | 6 |
3 | 1957.76 | 20 | 12.18 | 2870 | 6 | 6 |
4 | 1876.12 | 20 | 12.24 | 2802 | 6 | 6 |
5 | 1782.72 | 20 | 12.42 | 2647 | 6 | 6 |
6 | 1684.00 | 20 | 12.49 | 2545 | 6 | 6 |
7 | 907.88 | 20 | 13.09 | 1622 | 6 | 6 |
8 | 387.80 | 20 | 13.58 | 952 | 6 | 6 |
9 | 42.12 | 20 | 14.09 | 480 | 6 | 6 |
10 | 29.12 | 20 | 14.07 | 465 | 6 | 6 |
11 | 15.00 | 20 | 14.07 | 442 | 6 | 6 |
12 | 0.24 | 200 | 13.90 | 407 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.92 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2002.56 | 24 | 9.21 | 2792 | 6 | 6 |
3 | 1962.52 | 20 | 12.13 | 2902 | 6 | 6 |
4 | 1884.64 | 20 | 12.24 | 2807 | 6 | 6 |
5 | 1787.48 | 20 | 12.34 | 2710 | 6 | 6 |
6 | 1379.36 | 20 | 12.68 | 2230 | 6 | 6 |
7 | 955.96 | 20 | 13.06 | 1695 | 6 | 6 |
8 | 409.64 | 20 | 13.58 | 990 | 6 | 6 |
9 | 82.08 | 20 | 13.98 | 542 | 6 | 6 |
10 | 52.40 | 20 | 14.02 | 515 | 6 | 6 |
11 | 28.68 | 20 | 14.09 | 470 | 6 | 6 |
12 | 0.12 | 20 | 14.21 | 422 | 6 | 6 |
13 | 0.08 | 201 | 13.94 | 404 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.00 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2002.64 | 24 | 9.28 | 2749 | 6 | 6 |
3 | 1955.32 | 20 | 12.11 | 2915 | 6 | 6 |
4 | 1881.76 | 20 | 12.23 | 2827 | 6 | 6 |
5 | 1790.52 | 20 | 12.36 | 2700 | 6 | 6 |
6 | 1472.96 | 20 | 12.64 | 2312 | 6 | 6 |
7 | 834.56 | 20 | 13.17 | 1522 | 6 | 6 |
8 | 313.96 | 20 | 13.69 | 857 | 6 | 6 |
9 | 65.68 | 20 | 14.08 | 500 | 6 | 6 |
10 | 44.00 | 20 | 14.12 | 477 | 6 | 6 |
11 | 22.84 | 20 | 14.12 | 450 | 6 | 6 |
12 | 0.12 | 20 | 14.23 | 412 | 6 | 6 |
13 | 0.12 | 201 | 13.99 | 397 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.56 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2002.04 | 24 | 9.09 | 2847 | 6 | 6 |
3 | 1953.40 | 20 | 12.13 | 2885 | 6 | 6 |
4 | 1878.04 | 20 | 12.22 | 2830 | 6 | 6 |
5 | 1788.76 | 20 | 12.36 | 2695 | 6 | 6 |
6 | 1380.68 | 20 | 12.69 | 2227 | 6 | 6 |
7 | 956.16 | 20 | 13.09 | 1677 | 6 | 6 |
8 | 316.92 | 20 | 13.69 | 870 | 6 | 6 |
9 | 70.12 | 20 | 14.06 | 510 | 6 | 6 |
10 | 45.32 | 20 | 14.15 | 472 | 6 | 6 |
11 | 22.84 | 20 | 14.10 | 450 | 6 | 6 |
12 | 0.08 | 20 | 14.24 | 415 | 6 | 6 |
13 | 0.16 | 201 | 14.00 | 398 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.80 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2005.40 | 24 | 9.29 | 2763 | 6 | 6 |
3 | 1964.12 | 20 | 12.06 | 2910 | 6 | 6 |
4 | 1889.08 | 20 | 12.24 | 2797 | 6 | 6 |
5 | 1691.00 | 20 | 12.43 | 2595 | 6 | 6 |
6 | 1484.72 | 20 | 12.65 | 2327 | 6 | 6 |
7 | 946.12 | 20 | 13.08 | 1680 | 6 | 6 |
8 | 392.92 | 20 | 13.60 | 957 | 6 | 6 |
9 | 80.68 | 20 | 13.99 | 537 | 6 | 6 |
10 | 48.52 | 20 | 14.09 | 487 | 6 | 6 |
11 | 22.68 | 20 | 14.12 | 450 | 6 | 6 |
12 | 0.12 | 20 | 14.23 | 410 | 6 | 6 |
13 | 0.12 | 200 | 13.97 | 398 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2003.44 | 24 | 9.47 | 2746 | 6 | 6 |
3 | 1961.00 | 20 | 12.14 | 2887 | 6 | 6 |
4 | 1888.52 | 20 | 12.24 | 2830 | 6 | 6 |
5 | 1792.32 | 20 | 12.37 | 2695 | 6 | 6 |
6 | 1274.40 | 20 | 12.82 | 2075 | 6 | 6 |
7 | 960.88 | 20 | 13.07 | 1692 | 6 | 6 |
8 | 526.68 | 20 | 13.43 | 1165 | 6 | 6 |
9 | 78.80 | 20 | 13.98 | 557 | 6 | 6 |
10 | 46.84 | 20 | 14.08 | 495 | 6 | 6 |
11 | 23.00 | 20 | 14.10 | 457 | 6 | 6 |
12 | 0.16 | 20 | 14.21 | 430 | 6 | 6 |
13 | 0.08 | 201 | 13.92 | 405 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.52 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2002.72 | 24 | 9.45 | 2789 | 6 | 6 |
3 | 1964.16 | 20 | 12.07 | 2930 | 6 | 6 |
4 | 1902.32 | 20 | 12.28 | 2810 | 6 | 6 |
5 | 1814.88 | 20 | 12.38 | 2715 | 6 | 6 |
6 | 1305.52 | 20 | 12.81 | 2117 | 6 | 6 |
7 | 897.04 | 20 | 13.16 | 1610 | 6 | 6 |
8 | 458.00 | 20 | 13.55 | 1052 | 6 | 6 |
9 | 69.16 | 20 | 14.02 | 522 | 6 | 6 |
10 | 43.24 | 20 | 14.09 | 482 | 6 | 6 |
11 | 21.08 | 20 | 14.13 | 442 | 6 | 6 |
12 | 0.28 | 20 | 14.23 | 420 | 6 | 6 |
13 | 0.16 | 201 | 13.97 | 400 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.80 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2004.40 | 24 | 9.49 | 2787 | 6 | 6 |
3 | 1957.40 | 21 | 12.08 | 2880 | 6 | 6 |
4 | 1880.52 | 21 | 12.18 | 2817 | 6 | 6 |
5 | 1686.60 | 21 | 12.42 | 2586 | 6 | 6 |
6 | 1274.88 | 21 | 12.77 | 2088 | 6 | 6 |
7 | 643.32 | 21 | 13.31 | 1293 | 6 | 7 |
8 | 202.16 | 20 | 13.84 | 710 | 6 | 6 |
9 | 53.36 | 21 | 14.08 | 513 | 6 | 6 |
10 | 30.00 | 21 | 14.07 | 482 | 6 | 6 |
11 | 0.24 | 20 | 14.19 | 430 | 6 | 6 |
12 | 0.20 | 201 | 13.90 | 410 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.12 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2004.88 | 24 | 9.48 | 2809 | 6 | 6 |
3 | 1962.76 | 20 | 12.07 | 2927 | 6 | 6 |
4 | 1888.40 | 20 | 12.27 | 2820 | 6 | 6 |
5 | 1790.00 | 20 | 12.38 | 2705 | 6 | 6 |
6 | 1368.04 | 20 | 12.75 | 2197 | 6 | 6 |
7 | 853.72 | 20 | 13.18 | 1555 | 6 | 6 |
8 | 533.24 | 20 | 13.43 | 1157 | 6 | 6 |
9 | 82.88 | 20 | 13.96 | 555 | 6 | 6 |
10 | 42.52 | 20 | 14.09 | 497 | 6 | 6 |
11 | 22.48 | 20 | 14.09 | 462 | 6 | 6 |
12 | 0.12 | 20 | 14.19 | 432 | 6 | 6 |
13 | 0.04 | 201 | 13.89 | 410 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.60 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2001.08 | 24 | 9.60 | 2769 | 6 | 6 |
3 | 1958.44 | 20 | 12.07 | 2915 | 6 | 6 |
4 | 1887.68 | 20 | 12.27 | 2817 | 6 | 6 |
5 | 1790.32 | 20 | 12.41 | 2682 | 6 | 6 |
6 | 1471.40 | 20 | 12.64 | 2327 | 6 | 6 |
7 | 847.08 | 20 | 13.16 | 1557 | 6 | 6 |
8 | 526.52 | 20 | 13.47 | 1160 | 6 | 6 |
9 | 50.80 | 20 | 14.02 | 520 | 6 | 6 |
10 | 31.36 | 20 | 14.05 | 497 | 6 | 6 |
11 | 15.92 | 20 | 14.08 | 455 | 6 | 6 |
12 | 0.04 | 201 | 13.87 | 423 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2003.80 | 24 | 9.57 | 2766 | 6 | 6 |
3 | 1949.24 | 20 | 12.10 | 2887 | 6 | 6 |
4 | 1867.84 | 20 | 12.30 | 2782 | 6 | 6 |
5 | 1773.60 | 20 | 12.40 | 2680 | 6 | 6 |
6 | 1376.24 | 20 | 12.74 | 2200 | 6 | 6 |
7 | 937.92 | 20 | 13.09 | 1672 | 6 | 7 |
8 | 407.68 | 20 | 13.61 | 982 | 6 | 6 |
9 | 50.20 | 20 | 14.09 | 485 | 6 | 6 |
10 | 33.00 | 20 | 14.10 | 465 | 6 | 6 |
11 | 15.88 | 20 | 14.08 | 442 | 6 | 6 |
12 | 0.16 | 201 | 13.90 | 405 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.92 | 31 | 14.12 | 540 | 6 | 6 |
2 | 2001.76 | 24 | 9.64 | 2775 | 6 | 6 |
3 | 1960.28 | 20 | 12.17 | 2870 | 6 | 6 |
4 | 1881.08 | 20 | 12.25 | 2817 | 6 | 6 |
5 | 1784.56 | 20 | 12.42 | 2680 | 6 | 6 |
6 | 1367.92 | 20 | 12.76 | 2192 | 6 | 6 |
7 | 843.20 | 20 | 13.19 | 1540 | 6 | 6 |
8 | 406.04 | 20 | 13.57 | 1002 | 6 | 6 |
9 | 81.28 | 20 | 14.01 | 552 | 6 | 6 |
10 | 41.96 | 20 | 14.04 | 507 | 6 | 6 |
11 | 23.00 | 20 | 14.10 | 460 | 6 | 6 |
12 | 0.28 | 20 | 14.18 | 432 | 6 | 6 |
13 | 0.12 | 201 | 13.89 | 407 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.88 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2003.88 | 24 | 9.63 | 2775 | 6 | 6 |
3 | 1954.96 | 20 | 12.13 | 2882 | 6 | 6 |
4 | 1873.08 | 20 | 12.29 | 2805 | 6 | 6 |
5 | 1776.00 | 20 | 12.38 | 2692 | 6 | 6 |
6 | 1358.48 | 20 | 12.75 | 2182 | 6 | 6 |
7 | 834.56 | 20 | 13.16 | 1540 | 6 | 6 |
8 | 518.12 | 20 | 13.48 | 1132 | 6 | 6 |
9 | 73.32 | 20 | 13.99 | 542 | 6 | 6 |
10 | 46.08 | 20 | 14.06 | 502 | 6 | 6 |
11 | 25.32 | 20 | 14.09 | 462 | 6 | 6 |
12 | 0.16 | 20 | 14.19 | 432 | 6 | 6 |
13 | 0.08 | 201 | 13.89 | 410 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.40 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2005.32 | 24 | 9.62 | 2789 | 6 | 6 |
3 | 1958.20 | 20 | 12.12 | 2877 | 6 | 6 |
4 | 1879.56 | 20 | 12.30 | 2797 | 6 | 6 |
5 | 1683.24 | 20 | 12.48 | 2582 | 6 | 6 |
6 | 1377.52 | 20 | 12.73 | 2202 | 6 | 6 |
7 | 841.20 | 20 | 13.16 | 1552 | 6 | 6 |
8 | 515.32 | 20 | 13.48 | 1142 | 6 | 7 |
9 | 52.00 | 20 | 14.05 | 500 | 6 | 6 |
10 | 34.20 | 20 | 14.11 | 462 | 6 | 6 |
11 | 18.20 | 20 | 14.11 | 450 | 6 | 6 |
12 | 0.12 | 20 | 14.21 | 427 | 6 | 6 |
13 | 0.04 | 201 | 13.91 | 411 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.56 | 31 | 14.12 | 540 | 6 | 6 |
2 | 2016.92 | 24 | 9.67 | 2792 | 6 | 6 |
3 | 1967.64 | 20 | 12.08 | 2902 | 6 | 6 |
4 | 1891.96 | 20 | 12.29 | 2807 | 6 | 6 |
5 | 1803.04 | 20 | 12.40 | 2707 | 6 | 6 |
6 | 1285.84 | 20 | 12.77 | 2122 | 6 | 6 |
7 | 871.44 | 20 | 13.16 | 1592 | 6 | 6 |
8 | 534.88 | 20 | 13.46 | 1160 | 6 | 6 |
9 | 49.52 | 20 | 14.07 | 505 | 6 | 6 |
10 | 33.36 | 20 | 14.07 | 487 | 6 | 6 |
11 | 16.16 | 20 | 14.08 | 452 | 6 | 6 |
12 | 0.16 | 201 | 13.87 | 415 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.76 | 31 | 14.18 | 540 | 6 | 6 |
2 | 2002.88 | 24 | 9.73 | 2776 | 6 | 6 |
3 | 1952.84 | 20 | 12.11 | 2890 | 6 | 6 |
4 | 1879.28 | 20 | 12.29 | 2790 | 6 | 6 |
5 | 1785.12 | 20 | 12.45 | 2660 | 6 | 6 |
6 | 1472.20 | 20 | 12.69 | 2317 | 6 | 6 |
7 | 939.44 | 20 | 13.07 | 1685 | 6 | 7 |
8 | 391.92 | 20 | 13.56 | 995 | 6 | 6 |
9 | 49.76 | 20 | 14.07 | 500 | 6 | 6 |
10 | 30.68 | 20 | 14.12 | 470 | 6 | 6 |
11 | 15.96 | 20 | 14.10 | 447 | 6 | 6 |
12 | 0.60 | 200 | 13.89 | 406 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.12 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2003.52 | 24 | 9.77 | 2764 | 6 | 6 |
3 | 1964.00 | 20 | 12.12 | 2902 | 6 | 6 |
4 | 1886.16 | 20 | 12.24 | 2825 | 6 | 6 |
5 | 1688.96 | 20 | 12.50 | 2580 | 6 | 6 |
6 | 1370.20 | 20 | 12.80 | 2185 | 6 | 6 |
7 | 739.04 | 20 | 13.27 | 1417 | 6 | 6 |
8 | 332.16 | 20 | 13.66 | 900 | 6 | 6 |
9 | 60.16 | 20 | 14.07 | 512 | 6 | 6 |
10 | 41.44 | 20 | 14.12 | 482 | 6 | 6 |
11 | 19.24 | 20 | 14.13 | 442 | 6 | 6 |
12 | 0.08 | 20 | 14.23 | 417 | 6 | 6 |
13 | -0.00 | 201 | 13.93 | 402 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.64 | 31 | 14.18 | 500 | 6 | 6 |
2 | 2005.16 | 24 | 9.75 | 2763 | 6 | 6 |
3 | 1962.32 | 20 | 12.13 | 2890 | 6 | 6 |
4 | 1893.00 | 20 | 12.24 | 2832 | 6 | 6 |
5 | 1808.16 | 20 | 12.39 | 2722 | 6 | 6 |
6 | 1289.48 | 20 | 12.86 | 2092 | 6 | 6 |
7 | 868.56 | 20 | 13.20 | 1565 | 6 | 6 |
8 | 451.84 | 20 | 13.56 | 1035 | 6 | 6 |
9 | 64.72 | 20 | 14.07 | 517 | 6 | 6 |
10 | 43.16 | 20 | 14.09 | 490 | 6 | 6 |
11 | 0.16 | 20 | 14.25 | 417 | 6 | 6 |
12 | 0.12 | 201 | 13.94 | 400 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.44 | 31 | 14.12 | 520 | 6 | 6 |
2 | 2002.72 | 24 | 9.68 | 2798 | 6 | 6 |
3 | 1951.88 | 20 | 12.10 | 2890 | 6 | 6 |
4 | 1875.84 | 20 | 12.27 | 2802 | 6 | 6 |
5 | 1782.64 | 20 | 12.40 | 2700 | 6 | 6 |
6 | 1369.12 | 20 | 12.76 | 2205 | 6 | 6 |
7 | 949.12 | 20 | 13.15 | 1665 | 6 | 6 |
8 | 390.64 | 20 | 13.62 | 965 | 6 | 6 |
9 | 72.56 | 20 | 14.03 | 537 | 6 | 6 |
10 | 45.16 | 20 | 14.08 | 505 | 6 | 6 |
11 | 22.88 | 20 | 14.12 | 467 | 6 | 6 |
12 | 0.12 | 20 | 14.23 | 427 | 6 | 6 |
13 | 0.04 | 201 | 13.91 | 403 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.56 | 31 | 14.12 | 540 | 6 | 6 |
2 | 2003.00 | 24 | 9.77 | 2776 | 6 | 6 |
3 | 1955.60 | 20 | 12.14 | 2882 | 6 | 6 |
4 | 1880.68 | 20 | 12.31 | 2805 | 6 | 6 |
5 | 1787.40 | 20 | 12.45 | 2685 | 6 | 6 |
6 | 1359.40 | 20 | 12.77 | 2185 | 6 | 6 |
7 | 928.68 | 20 | 13.14 | 1660 | 6 | 6 |
8 | 592.92 | 20 | 13.44 | 1230 | 6 | 7 |
9 | 61.88 | 20 | 14.05 | 505 | 6 | 6 |
10 | 37.84 | 20 | 14.09 | 475 | 6 | 6 |
11 | 17.84 | 20 | 14.13 | 437 | 6 | 6 |
12 | 0.12 | 20 | 14.24 | 417 | 6 | 6 |
13 | 0.08 | 200 | 13.91 | 399 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 31 | 14.18 | 540 | 6 | 6 |
2 | 2003.52 | 24 | 9.70 | 2810 | 6 | 6 |
3 | 1956.36 | 20 | 12.09 | 2897 | 6 | 6 |
4 | 1885.76 | 20 | 12.27 | 2827 | 6 | 6 |
5 | 1790.12 | 20 | 12.39 | 2725 | 6 | 6 |
6 | 1462.36 | 20 | 12.74 | 2305 | 6 | 7 |
7 | 1133.24 | 20 | 12.96 | 1930 | 6 | 6 |
8 | 347.68 | 20 | 13.73 | 905 | 6 | 6 |
9 | 65.64 | 20 | 14.06 | 530 | 6 | 6 |
10 | 43.60 | 20 | 14.09 | 500 | 6 | 6 |
11 | 21.68 | 20 | 14.12 | 460 | 6 | 6 |
12 | 0.20 | 20 | 14.24 | 427 | 6 | 6 |
13 | 0.16 | 201 | 13.90 | 412 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.92 | 31 | 14.18 | 540 | 6 | 6 |
2 | 2003.36 | 24 | 9.72 | 2776 | 6 | 6 |
3 | 1953.08 | 21 | 12.11 | 2864 | 6 | 6 |
4 | 1875.96 | 21 | 12.21 | 2817 | 6 | 6 |
5 | 1585.88 | 20 | 12.65 | 2457 | 6 | 6 |
6 | 1174.40 | 20 | 12.95 | 1967 | 6 | 6 |
7 | 661.24 | 20 | 13.40 | 1307 | 6 | 6 |
8 | 141.16 | 20 | 13.93 | 632 | 6 | 6 |
9 | 66.56 | 20 | 14.09 | 520 | 6 | 6 |
10 | 41.04 | 20 | 14.12 | 482 | 6 | 6 |
11 | 0.24 | 20 | 14.27 | 420 | 6 | 6 |
12 | 0.12 | 201 | 13.92 | 408 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.04 | 31 | 14.18 | 520 | 6 | 6 |
2 | 2002.00 | 24 | 9.65 | 2827 | 6 | 6 |
3 | 1955.20 | 20 | 12.16 | 2887 | 6 | 6 |
4 | 1881.04 | 21 | 12.23 | 2820 | 6 | 6 |
5 | 1783.84 | 20 | 12.42 | 2700 | 6 | 6 |
6 | 1257.80 | 20 | 12.88 | 2067 | 6 | 7 |
7 | 841.20 | 20 | 13.24 | 1542 | 6 | 6 |
8 | 412.36 | 20 | 13.63 | 990 | 6 | 6 |
9 | 58.48 | 20 | 14.08 | 520 | 6 | 6 |
10 | 39.44 | 20 | 14.13 | 490 | 6 | 6 |
11 | 20.16 | 20 | 14.15 | 452 | 6 | 6 |
12 | 0.12 | 20 | 14.27 | 422 | 6 | 6 |
13 | 0.12 | 200 | 13.94 | 404 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.64 | 30 | 14.18 | 540 | 6 | 6 |
2 | 2002.84 | 24 | 9.76 | 2793 | 6 | 6 |
3 | 1953.88 | 20 | 12.14 | 2897 | 6 | 6 |
4 | 1879.04 | 20 | 12.33 | 2812 | 6 | 6 |
5 | 1585.12 | 20 | 12.64 | 2457 | 6 | 6 |
6 | 1098.76 | 20 | 13.01 | 1885 | 6 | 6 |
7 | 694.88 | 20 | 13.36 | 1360 | 6 | 7 |
8 | 280.60 | 20 | 13.77 | 832 | 6 | 6 |
9 | 54.28 | 20 | 14.12 | 510 | 6 | 6 |
10 | 37.08 | 20 | 14.12 | 485 | 6 | 6 |
11 | 16.76 | 20 | 14.15 | 450 | 6 | 6 |
12 | 0.12 | 20 | 14.28 | 425 | 6 | 6 |
13 | 0.08 | 201 | 13.95 | 403 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.24 | 30 | 14.18 | 520 | 6 | 6 |
2 | 2007.84 | 24 | 9.70 | 2792 | 6 | 6 |
3 | 1971.20 | 20 | 12.14 | 2917 | 6 | 6 |
4 | 1896.28 | 20 | 12.31 | 2825 | 6 | 6 |
5 | 1701.36 | 20 | 12.56 | 2582 | 6 | 6 |
6 | 1295.24 | 20 | 12.90 | 2092 | 6 | 6 |
7 | 778.52 | 20 | 13.29 | 1472 | 6 | 6 |
8 | 346.88 | 20 | 13.67 | 932 | 6 | 6 |
9 | 59.56 | 20 | 14.09 | 522 | 6 | 6 |
10 | 42.20 | 20 | 14.12 | 500 | 6 | 6 |
11 | 20.92 | 20 | 14.13 | 465 | 6 | 6 |
12 | 0.08 | 20 | 14.24 | 437 | 6 | 6 |
13 | 0.04 | 201 | 13.89 | 418 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.44 | 30 | 14.18 | 520 | 6 | 6 |
2 | 2003.96 | 24 | 9.55 | 2824 | 6 | 6 |
3 | 1955.52 | 20 | 12.12 | 2912 | 6 | 6 |
4 | 1883.68 | 20 | 12.31 | 2817 | 6 | 6 |
5 | 1786.36 | 20 | 12.42 | 2710 | 6 | 6 |
6 | 1356.84 | 20 | 12.84 | 2185 | 6 | 6 |
7 | 829.76 | 20 | 13.23 | 1550 | 6 | 6 |
8 | 406.40 | 20 | 13.66 | 982 | 6 | 6 |
9 | 58.92 | 20 | 14.08 | 515 | 6 | 6 |
10 | 45.92 | 20 | 14.15 | 492 | 6 | 6 |
11 | 24.68 | 20 | 14.15 | 460 | 6 | 6 |
12 | 0.20 | 20 | 14.27 | 422 | 6 | 6 |
13 | 0.12 | 201 | 13.94 | 406 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 30 | 14.18 | 520 | 6 | 6 |
2 | 2003.88 | 24 | 9.57 | 2823 | 6 | 6 |
3 | 1959.40 | 20 | 12.20 | 2880 | 6 | 6 |
4 | 1875.24 | 20 | 12.31 | 2832 | 6 | 6 |
5 | 1670.72 | 20 | 12.64 | 2555 | 6 | 6 |
6 | 1262.68 | 20 | 12.93 | 2072 | 6 | 7 |
7 | 735.84 | 20 | 13.33 | 1410 | 6 | 6 |
8 | 309.56 | 20 | 13.75 | 857 | 6 | 6 |
9 | 47.28 | 20 | 14.12 | 490 | 6 | 6 |
10 | 33.76 | 20 | 14.13 | 480 | 6 | 6 |
11 | 17.88 | 20 | 14.12 | 457 | 6 | 6 |
12 | 0.08 | 20 | 14.24 | 427 | 6 | 6 |
13 | 0.12 | 201 | 13.89 | 405 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.92 | 30 | 14.18 | 540 | 6 | 6 |
2 | 2002.44 | 24 | 9.41 | 2866 | 6 | 6 |
3 | 1953.60 | 20 | 12.20 | 2890 | 6 | 6 |
4 | 1878.36 | 20 | 12.40 | 2792 | 6 | 6 |
5 | 1779.36 | 20 | 12.51 | 2672 | 6 | 6 |
6 | 1460.36 | 20 | 12.78 | 2302 | 6 | 6 |
7 | 826.72 | 20 | 13.25 | 1530 | 6 | 6 |
8 | 406.36 | 20 | 13.63 | 992 | 6 | 6 |
9 | 40.72 | 20 | 14.09 | 497 | 6 | 6 |
10 | 32.80 | 20 | 14.12 | 477 | 6 | 6 |
11 | 17.60 | 20 | 14.09 | 460 | 6 | 6 |
12 | 0.16 | 20 | 14.23 | 427 | 6 | 6 |
13 | 0.08 | 201 | 13.88 | 399 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.20 | 30 | 14.25 | 520 | 6 | 6 |
2 | 2000.44 | 24 | 9.48 | 2861 | 6 | 6 |
3 | 1958.08 | 20 | 12.25 | 2875 | 6 | 6 |
4 | 1883.84 | 20 | 12.34 | 2820 | 6 | 6 |
5 | 1787.04 | 20 | 12.48 | 2707 | 6 | 6 |
6 | 1290.68 | 20 | 12.91 | 2115 | 6 | 6 |
7 | 871.40 | 20 | 13.22 | 1592 | 6 | 6 |
8 | 340.44 | 20 | 13.69 | 912 | 6 | 6 |
9 | 32.32 | 20 | 14.10 | 495 | 6 | 6 |
10 | 25.92 | 20 | 14.09 | 482 | 6 | 6 |
11 | 15.92 | 20 | 14.09 | 457 | 6 | 6 |
12 | 0.68 | 200 | 13.82 | 420 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 30 | 14.18 | 540 | 6 | 6 |
2 | 2002.68 | 24 | 9.21 | 2927 | 6 | 6 |
3 | 1949.44 | 20 | 12.20 | 2895 | 6 | 6 |
4 | 1867.12 | 20 | 12.35 | 2807 | 6 | 6 |
5 | 1673.96 | 20 | 12.63 | 2572 | 6 | 6 |
6 | 1166.44 | 20 | 13.02 | 1965 | 6 | 6 |
7 | 850.32 | 20 | 13.25 | 1572 | 6 | 7 |
8 | 309.64 | 20 | 13.76 | 867 | 6 | 6 |
9 | 40.08 | 20 | 14.09 | 500 | 6 | 6 |
10 | 23.20 | 20 | 14.11 | 485 | 6 | 6 |
11 | 12.16 | 20 | 14.07 | 462 | 6 | 6 |
12 | -0.00 | 20 | 14.12 | 432 | 6 | 6 |
13 | 0.04 | 201 | 13.74 | 415 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.72 | 30 | 14.18 | 540 | 6 | 6 |
2 | 2001.08 | 24 | 9.26 | 2864 | 6 | 6 |
3 | 1949.84 | 20 | 12.21 | 2887 | 6 | 6 |
4 | 1868.00 | 20 | 12.38 | 2790 | 6 | 6 |
5 | 1770.52 | 20 | 12.48 | 2697 | 6 | 6 |
6 | 1255.84 | 20 | 12.91 | 2097 | 6 | 6 |
7 | 842.88 | 20 | 13.26 | 1570 | 6 | 7 |
8 | 416.80 | 20 | 13.64 | 1022 | 6 | 6 |
9 | 37.52 | 20 | 14.13 | 487 | 6 | 6 |
10 | 24.12 | 20 | 14.12 | 475 | 6 | 6 |
11 | 13.08 | 20 | 14.07 | 460 | 6 | 6 |
12 | 0.08 | 20 | 14.11 | 442 | 6 | 6 |
13 | -0.00 | 201 | 13.76 | 411 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 30 | 14.18 | 540 | 6 | 6 |
2 | 2000.80 | 24 | 9.21 | 2921 | 6 | 6 |
3 | 1954.84 | 20 | 12.20 | 2885 | 6 | 6 |
4 | 1879.60 | 20 | 12.28 | 2862 | 6 | 6 |
5 | 1786.92 | 20 | 12.46 | 2710 | 6 | 6 |
6 | 1372.76 | 20 | 12.89 | 2207 | 6 | 7 |
7 | 842.60 | 20 | 13.26 | 1565 | 6 | 6 |
8 | 308.12 | 20 | 13.77 | 877 | 6 | 6 |
9 | 42.36 | 20 | 14.10 | 517 | 6 | 6 |
10 | 28.84 | 20 | 14.13 | 480 | 6 | 6 |
11 | 16.08 | 20 | 14.09 | 465 | 6 | 6 |
12 | 0.36 | 201 | 13.83 | 411 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.92 | 30 | 14.25 | 520 | 6 | 6 |
2 | 2003.28 | 24 | 9.36 | 2896 | 6 | 6 |
3 | 1950.64 | 20 | 12.28 | 2870 | 6 | 6 |
4 | 1863.80 | 20 | 12.38 | 2802 | 6 | 6 |
5 | 1767.44 | 20 | 12.47 | 2692 | 6 | 6 |
6 | 1569.88 | 20 | 12.73 | 2450 | 6 | 6 |
7 | 907.96 | 20 | 13.17 | 1657 | 6 | 7 |
8 | 280.00 | 20 | 13.81 | 830 | 6 | 6 |
9 | 41.80 | 20 | 14.16 | 502 | 6 | 6 |
10 | 28.00 | 20 | 14.12 | 482 | 6 | 6 |
11 | 15.56 | 20 | 14.10 | 462 | 6 | 6 |
12 | 0.72 | 201 | 13.83 | 416 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 30 | 14.18 | 540 | 6 | 6 |
2 | 2004.88 | 24 | 9.43 | 2920 | 6 | 6 |
3 | 1954.12 | 20 | 12.26 | 2885 | 6 | 6 |
4 | 1876.08 | 20 | 12.41 | 2775 | 6 | 6 |
5 | 1783.72 | 20 | 12.52 | 2685 | 6 | 6 |
6 | 1373.16 | 20 | 12.87 | 2225 | 6 | 6 |
7 | 939.64 | 20 | 13.22 | 1675 | 6 | 6 |
8 | 390.36 | 20 | 13.68 | 982 | 6 | 6 |
9 | 37.56 | 20 | 14.15 | 497 | 6 | 6 |
10 | 26.92 | 20 | 14.12 | 482 | 6 | 6 |
11 | 14.28 | 20 | 14.10 | 450 | 6 | 6 |
12 | 0.08 | 200 | 13.83 | 415 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 30 | 14.25 | 520 | 6 | 6 |
2 | 2002.40 | 24 | 9.55 | 2910 | 6 | 6 |
3 | 1956.16 | 20 | 12.19 | 2902 | 6 | 6 |
4 | 1877.52 | 20 | 12.37 | 2815 | 6 | 6 |
5 | 1680.44 | 20 | 12.60 | 2605 | 6 | 6 |
6 | 1270.80 | 20 | 12.94 | 2105 | 6 | 6 |
7 | 846.52 | 20 | 13.27 | 1580 | 6 | 6 |
8 | 299.68 | 20 | 13.80 | 855 | 6 | 6 |
9 | 48.48 | 20 | 14.13 | 520 | 6 | 6 |
10 | 30.32 | 20 | 14.15 | 487 | 6 | 6 |
11 | 15.12 | 20 | 14.12 | 455 | 6 | 6 |
12 | 0.08 | 200 | 13.86 | 418 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 30 | 14.25 | 540 | 6 | 6 |
2 | 2004.08 | 24 | 9.82 | 2904 | 6 | 6 |
3 | 1949.84 | 20 | 12.17 | 2920 | 6 | 6 |
4 | 1865.04 | 20 | 12.39 | 2800 | 6 | 6 |
5 | 1673.72 | 20 | 12.66 | 2562 | 6 | 6 |
6 | 1259.08 | 20 | 12.98 | 2077 | 6 | 6 |
7 | 832.72 | 20 | 13.32 | 1547 | 6 | 6 |
8 | 203.84 | 20 | 13.95 | 722 | 6 | 6 |
9 | 51.08 | 20 | 14.16 | 525 | 6 | 6 |
10 | 33.60 | 20 | 14.18 | 487 | 6 | 6 |
11 | 1.24 | 20 | 14.24 | 435 | 6 | 6 |
12 | 0.12 | 201 | 13.89 | 411 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.20 | 30 | 14.25 | 520 | 6 | 6 |
2 | 2017.96 | 24 | 9.79 | 2907 | 6 | 6 |
3 | 1979.32 | 20 | 12.21 | 2915 | 6 | 6 |
4 | 1898.00 | 20 | 12.33 | 2825 | 6 | 6 |
5 | 1590.20 | 20 | 12.72 | 2477 | 6 | 6 |
6 | 1196.72 | 20 | 13.02 | 2002 | 6 | 6 |
7 | 785.80 | 20 | 13.37 | 1482 | 6 | 6 |
8 | 254.12 | 20 | 13.87 | 790 | 6 | 6 |
9 | 66.76 | 20 | 14.15 | 537 | 6 | 6 |
10 | 40.44 | 20 | 14.20 | 492 | 6 | 6 |
11 | 0.16 | 20 | 14.32 | 427 | 6 | 6 |
12 | 0.12 | 201 | 13.93 | 415 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.68 | 30 | 14.31 | 520 | 6 | 6 |
2 | 2005.24 | 24 | 9.92 | 2890 | 6 | 6 |
3 | 1974.20 | 20 | 12.26 | 2887 | 6 | 6 |
4 | 1893.60 | 20 | 12.36 | 2830 | 6 | 6 |
5 | 1695.04 | 20 | 12.66 | 2605 | 6 | 6 |
6 | 1272.68 | 20 | 12.98 | 2110 | 6 | 6 |
7 | 942.44 | 20 | 13.20 | 1712 | 6 | 6 |
8 | 204.80 | 20 | 13.94 | 732 | 6 | 6 |
9 | 52.92 | 20 | 14.19 | 525 | 6 | 6 |
10 | 34.64 | 20 | 14.18 | 492 | 6 | 6 |
11 | 17.80 | 20 | 14.14 | 465 | 6 | 6 |
12 | 0.72 | 200 | 13.88 | 421 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 30 | 14.31 | 520 | 6 | 6 |
2 | 2004.24 | 24 | 9.93 | 2887 | 6 | 6 |
3 | 1947.44 | 20 | 12.30 | 2847 | 6 | 6 |
4 | 1865.88 | 20 | 12.36 | 2812 | 6 | 6 |
5 | 1674.84 | 20 | 12.69 | 2567 | 6 | 6 |
6 | 1474.52 | 20 | 12.83 | 2347 | 6 | 7 |
7 | 820.64 | 20 | 13.33 | 1535 | 6 | 7 |
8 | 381.04 | 20 | 13.77 | 977 | 6 | 6 |
9 | 63.64 | 20 | 14.15 | 530 | 6 | 6 |
10 | 38.16 | 20 | 14.18 | 505 | 6 | 6 |
11 | 19.12 | 20 | 14.15 | 470 | 6 | 6 |
12 | 0.04 | 20 | 14.28 | 432 | 6 | 6 |
13 | 0.04 | 201 | 13.91 | 409 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.96 | 30 | 14.37 | 520 | 6 | 6 |
2 | 2002.08 | 24 | 10.38 | 2872 | 6 | 6 |
3 | 1947.52 | 20 | 12.26 | 2885 | 6 | 6 |
4 | 1862.24 | 20 | 12.39 | 2810 | 6 | 6 |
5 | 1764.64 | 20 | 12.51 | 2685 | 6 | 6 |
6 | 1235.44 | 20 | 13.02 | 2055 | 6 | 6 |
7 | 696.92 | 20 | 13.44 | 1402 | 6 | 6 |
8 | 372.36 | 20 | 13.80 | 965 | 6 | 6 |
9 | 58.20 | 20 | 14.14 | 530 | 6 | 6 |
10 | 36.00 | 20 | 14.19 | 497 | 6 | 6 |
11 | 0.60 | 200 | 13.95 | 420 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.20 | 30 | 14.31 | 540 | 6 | 6 |
2 | 2001.52 | 24 | 10.40 | 2892 | 6 | 6 |
3 | 1947.84 | 20 | 12.25 | 2895 | 6 | 6 |
4 | 1866.84 | 20 | 12.45 | 2792 | 6 | 6 |
5 | 1666.84 | 20 | 12.71 | 2577 | 6 | 6 |
6 | 1251.24 | 20 | 13.00 | 2102 | 6 | 6 |
7 | 637.24 | 20 | 13.55 | 1292 | 6 | 7 |
8 | 217.28 | 20 | 13.96 | 742 | 6 | 6 |
9 | 53.16 | 20 | 14.19 | 517 | 6 | 6 |
10 | 32.20 | 20 | 14.21 | 482 | 6 | 6 |
11 | 0.04 | 201 | 13.96 | 416 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.76 | 30 | 14.31 | 540 | 6 | 6 |
2 | 2004.64 | 24 | 10.55 | 2907 | 6 | 6 |
3 | 1953.68 | 20 | 12.27 | 2917 | 6 | 6 |
4 | 1873.88 | 20 | 12.38 | 2847 | 6 | 6 |
5 | 1775.96 | 20 | 12.57 | 2680 | 6 | 6 |
6 | 1333.52 | 20 | 13.01 | 2157 | 6 | 6 |
7 | 679.88 | 20 | 13.49 | 1367 | 6 | 6 |
8 | 262.80 | 20 | 13.93 | 812 | 6 | 6 |
9 | 42.88 | 20 | 14.20 | 515 | 6 | 6 |
10 | 27.48 | 20 | 14.19 | 482 | 6 | 6 |
11 | 0.04 | 20 | 14.28 | 440 | 6 | 6 |
12 | 0.08 | 201 | 13.92 | 412 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.32 | 30 | 14.37 | 520 | 6 | 6 |
2 | 2003.00 | 24 | 10.75 | 2909 | 6 | 6 |
3 | 1953.00 | 21 | 12.24 | 2895 | 6 | 6 |
4 | 1866.04 | 20 | 12.46 | 2802 | 6 | 6 |
5 | 1660.24 | 20 | 12.74 | 2562 | 6 | 6 |
6 | 1238.16 | 20 | 13.09 | 2050 | 6 | 6 |
7 | 708.12 | 20 | 13.49 | 1400 | 6 | 6 |
8 | 175.76 | 20 | 14.05 | 677 | 6 | 6 |
9 | 41.24 | 20 | 14.26 | 500 | 6 | 6 |
10 | 22.80 | 20 | 14.23 | 467 | 6 | 6 |
11 | 0.04 | 20 | 14.29 | 432 | 6 | 6 |
12 | -0.00 | 201 | 13.93 | 405 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.68 | 30 | 14.37 | 520 | 6 | 6 |
2 | 2003.72 | 24 | 10.88 | 2946 | 6 | 6 |
3 | 1952.40 | 20 | 12.37 | 2912 | 6 | 6 |
4 | 1869.32 | 20 | 12.48 | 2795 | 6 | 6 |
5 | 1567.24 | 20 | 12.87 | 2455 | 6 | 6 |
6 | 1145.68 | 20 | 13.17 | 1937 | 6 | 6 |
7 | 719.84 | 20 | 13.52 | 1400 | 6 | 6 |
8 | 168.36 | 20 | 14.05 | 685 | 6 | 6 |
9 | 44.12 | 20 | 14.27 | 502 | 6 | 6 |
10 | 27.12 | 20 | 14.24 | 472 | 6 | 6 |
11 | 12.84 | 20 | 14.16 | 457 | 6 | 6 |
12 | -0.00 | 20 | 14.20 | 435 | 6 | 6 |
13 | -0.00 | 201 | 13.89 | 409 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.56 | 30 | 14.37 | 540 | 6 | 6 |
2 | 2001.92 | 24 | 11.07 | 2963 | 6 | 6 |
3 | 1939.68 | 20 | 12.42 | 2875 | 6 | 6 |
4 | 1853.04 | 20 | 12.52 | 2790 | 6 | 6 |
5 | 1658.96 | 21 | 12.77 | 2553 | 6 | 6 |
6 | 1123.48 | 20 | 13.22 | 1925 | 6 | 6 |
7 | 709.96 | 20 | 13.55 | 1397 | 6 | 6 |
8 | 83.08 | 21 | 14.18 | 551 | 6 | 6 |
9 | 49.24 | 20 | 14.24 | 512 | 6 | 6 |
10 | 30.36 | 20 | 14.23 | 480 | 6 | 6 |
11 | 0.04 | 201 | 14.01 | 408 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.36 | 30 | 14.37 | 540 | 6 | 6 |
2 | 2003.88 | 24 | 11.45 | 2938 | 6 | 6 |
3 | 1943.00 | 20 | 12.48 | 2902 | 6 | 6 |
4 | 1856.56 | 20 | 12.56 | 2785 | 6 | 6 |
5 | 1652.84 | 20 | 12.83 | 2572 | 6 | 6 |
6 | 1231.08 | 20 | 13.17 | 2060 | 6 | 6 |
7 | 677.32 | 20 | 13.58 | 1355 | 6 | 6 |
8 | 132.00 | 20 | 14.13 | 632 | 6 | 6 |
9 | 65.52 | 20 | 14.26 | 532 | 6 | 6 |
10 | 31.68 | 20 | 14.27 | 480 | 6 | 6 |
11 | 0.08 | 200 | 14.02 | 413 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.56 | 30 | 14.37 | 540 | 6 | 6 |
2 | 2003.20 | 24 | 11.61 | 2940 | 6 | 6 |
3 | 1951.00 | 20 | 12.52 | 2892 | 6 | 6 |
4 | 1866.88 | 20 | 12.62 | 2775 | 6 | 6 |
5 | 1667.64 | 20 | 12.88 | 2567 | 6 | 6 |
6 | 1038.28 | 20 | 13.32 | 1820 | 6 | 6 |
7 | 515.24 | 20 | 13.75 | 1155 | 6 | 6 |
8 | 99.20 | 20 | 14.18 | 582 | 6 | 6 |
9 | 52.04 | 20 | 14.26 | 512 | 6 | 6 |
10 | 26.04 | 20 | 14.25 | 470 | 6 | 6 |
11 | 0.12 | 20 | 14.32 | 430 | 6 | 6 |
12 | 0.04 | 201 | 13.97 | 411 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.48 | 30 | 14.37 | 540 | 6 | 6 |
2 | 2000.96 | 24 | 11.85 | 2940 | 6 | 6 |
3 | 1940.56 | 20 | 12.58 | 2870 | 6 | 6 |
4 | 1855.32 | 20 | 12.56 | 2822 | 6 | 6 |
5 | 1553.28 | 20 | 12.97 | 2450 | 6 | 6 |
6 | 1138.24 | 20 | 13.28 | 1930 | 6 | 6 |
7 | 805.72 | 21 | 13.49 | 1517 | 6 | 6 |
8 | 74.24 | 20 | 14.21 | 562 | 6 | 6 |
9 | 43.52 | 20 | 14.26 | 515 | 6 | 6 |
10 | 20.64 | 20 | 14.26 | 472 | 6 | 6 |
11 | 0.08 | 20 | 14.34 | 442 | 6 | 6 |
12 | 0.04 | 201 | 13.97 | 422 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.68 | 30 | 14.37 | 540 | 6 | 6 |
2 | 2000.80 | 24 | 12.03 | 2944 | 6 | 6 |
3 | 1926.44 | 21 | 12.50 | 2880 | 6 | 6 |
4 | 1829.88 | 21 | 12.59 | 2755 | 6 | 6 |
5 | 1532.88 | 21 | 12.95 | 2420 | 6 | 6 |
6 | 914.96 | 21 | 13.38 | 1664 | 6 | 6 |
7 | 480.28 | 21 | 13.75 | 1108 | 6 | 6 |
8 | 77.04 | 21 | 14.21 | 564 | 6 | 6 |
9 | 44.44 | 21 | 14.26 | 511 | 6 | 6 |
10 | 0.04 | 20 | 14.38 | 440 | 6 | 6 |
11 | 0.04 | 200 | 14.02 | 413 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 30 | 14.43 | 540 | 6 | 6 |
2 | 2001.88 | 24 | 12.31 | 2952 | 6 | 6 |
3 | 1936.24 | 20 | 12.60 | 2885 | 6 | 6 |
4 | 1846.24 | 20 | 12.69 | 2775 | 6 | 6 |
5 | 1654.52 | 20 | 12.94 | 2557 | 6 | 6 |
6 | 1105.36 | 20 | 13.30 | 1890 | 6 | 6 |
7 | 562.40 | 20 | 13.74 | 1202 | 6 | 6 |
8 | 76.52 | 20 | 14.26 | 562 | 6 | 6 |
9 | 51.72 | 20 | 14.27 | 525 | 6 | 6 |
10 | 26.04 | 20 | 14.27 | 472 | 6 | 6 |
11 | 0.08 | 20 | 14.37 | 432 | 6 | 6 |
12 | 0.08 | 201 | 14.02 | 412 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 30 | 14.43 | 540 | 6 | 6 |
2 | 2002.52 | 24 | 12.46 | 2952 | 6 | 6 |
3 | 1932.68 | 21 | 12.58 | 2895 | 6 | 6 |
4 | 1850.72 | 21 | 12.68 | 2764 | 6 | 6 |
5 | 1755.00 | 21 | 12.71 | 2682 | 6 | 6 |
6 | 870.56 | 21 | 13.44 | 1631 | 6 | 6 |
7 | 458.00 | 21 | 13.83 | 1082 | 6 | 6 |
8 | 70.64 | 21 | 14.29 | 551 | 6 | 6 |
9 | 40.96 | 21 | 14.27 | 506 | 6 | 6 |
10 | 0.08 | 20 | 14.43 | 445 | 6 | 6 |
11 | 0.08 | 201 | 14.05 | 418 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 30 | 14.43 | 540 | 6 | 6 |
2 | 2006.08 | 24 | 12.63 | 2950 | 6 | 6 |
3 | 1951.28 | 21 | 12.67 | 2877 | 6 | 6 |
4 | 1861.00 | 21 | 12.67 | 2817 | 6 | 6 |
5 | 1545.88 | 21 | 13.00 | 2440 | 6 | 6 |
6 | 1096.64 | 21 | 13.32 | 1902 | 6 | 6 |
7 | 535.44 | 21 | 13.76 | 1195 | 6 | 6 |
8 | 81.72 | 21 | 14.28 | 564 | 6 | 6 |
9 | 48.36 | 21 | 14.26 | 524 | 6 | 6 |
10 | 7.64 | 21 | 14.35 | 455 | 6 | 6 |
11 | 0.04 | 20 | 14.33 | 445 | 6 | 6 |
12 | -0.00 | 201 | 14.01 | 417 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.60 | 29 | 14.43 | 560 | 6 | 6 |
2 | 2004.04 | 24 | 12.74 | 2975 | 6 | 6 |
3 | 1943.36 | 21 | 12.71 | 2908 | 6 | 6 |
4 | 1853.20 | 21 | 12.71 | 2802 | 6 | 6 |
5 | 1442.16 | 21 | 13.14 | 2293 | 6 | 6 |
6 | 922.96 | 21 | 13.49 | 1660 | 6 | 6 |
7 | 382.16 | 21 | 13.96 | 962 | 6 | 6 |
8 | 75.12 | 21 | 14.32 | 540 | 6 | 6 |
9 | 41.80 | 21 | 14.33 | 482 | 6 | 6 |
10 | 0.04 | 20 | 14.47 | 420 | 6 | 6 |
11 | -0.00 | 201 | 14.08 | 403 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.24 | 29 | 14.43 | 560 | 6 | 6 |
2 | 2004.52 | 62 | 12.24 | 2959 | 6 | 6 |
3 | 1573.32 | 25 | 13.02 | 2474 | 6 | 6 |
4 | 906.80 | 25 | 13.47 | 1670 | 6 | 6 |
5 | 236.84 | 25 | 14.12 | 780 | 6 | 6 |
6 | 58.80 | 25 | 14.35 | 540 | 6 | 6 |
7 | 31.64 | 25 | 14.31 | 488 | 6 | 6 |
8 | 0.12 | 24 | 14.38 | 442 | 6 | 6 |
9 | -0.00 | 251 | 13.97 | 437 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.92 | 29 | 14.43 | 580 | 6 | 6 |
2 | 2001.32 | 62 | 12.27 | 2958 | 6 | 6 |
3 | 1536.40 | 25 | 13.03 | 2440 | 6 | 6 |
4 | 844.28 | 25 | 13.53 | 1586 | 6 | 6 |
5 | 178.28 | 25 | 14.17 | 712 | 6 | 6 |
6 | 47.96 | 25 | 14.36 | 530 | 6 | 6 |
7 | 28.80 | 25 | 14.29 | 484 | 6 | 6 |
8 | 0.04 | 24 | 14.37 | 440 | 6 | 6 |
9 | -0.00 | 251 | 13.96 | 434 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.36 | 29 | 14.43 | 580 | 6 | 6 |
2 | 2003.96 | 62 | 12.30 | 2950 | 6 | 6 |
3 | 1376.00 | 25 | 13.17 | 2234 | 6 | 6 |
4 | 923.08 | 25 | 13.49 | 1688 | 6 | 6 |
5 | 234.72 | 25 | 14.10 | 800 | 6 | 6 |
6 | 66.12 | 25 | 14.35 | 552 | 6 | 6 |
7 | 35.00 | 25 | 14.34 | 498 | 6 | 6 |
8 | 0.04 | 250 | 14.07 | 429 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.60 | 29 | 14.43 | 580 | 6 | 6 |
2 | 2002.84 | 62 | 12.32 | 2956 | 6 | 6 |
3 | 1574.84 | 25 | 13.07 | 2476 | 6 | 6 |
4 | 883.12 | 25 | 13.54 | 1630 | 6 | 6 |
5 | 182.52 | 25 | 14.20 | 720 | 6 | 6 |
6 | 100.16 | 25 | 14.32 | 608 | 6 | 6 |
7 | 53.68 | 25 | 14.38 | 522 | 6 | 6 |
8 | 0.12 | 24 | 14.53 | 436 | 6 | 6 |
9 | 0.04 | 251 | 14.10 | 426 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.56 | 29 | 14.50 | 580 | 7 | 6 |
2 | 2003.88 | 62 | 12.34 | 2953 | 6 | 6 |
3 | 1555.76 | 25 | 13.12 | 2440 | 6 | 6 |
4 | 1090.76 | 25 | 13.42 | 1876 | 6 | 6 |
5 | 181.36 | 25 | 14.22 | 722 | 6 | 6 |
6 | 107.16 | 25 | 14.32 | 608 | 6 | 6 |
7 | 59.00 | 25 | 14.37 | 544 | 6 | 6 |
8 | 0.08 | 24 | 14.54 | 446 | 6 | 6 |
9 | 0.04 | 251 | 14.11 | 440 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.00 | 29 | 14.50 | 560 | 6 | 6 |
2 | 2002.52 | 62 | 12.37 | 2940 | 6 | 6 |
3 | 1549.88 | 25 | 13.14 | 2424 | 6 | 6 |
4 | 863.36 | 25 | 13.57 | 1616 | 6 | 6 |
5 | 184.08 | 25 | 14.24 | 726 | 6 | 6 |
6 | 110.40 | 25 | 14.32 | 616 | 6 | 6 |
7 | 59.08 | 25 | 14.40 | 532 | 6 | 6 |
8 | 0.16 | 24 | 14.53 | 450 | 6 | 6 |
9 | 0.16 | 251 | 14.12 | 441 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.68 | 29 | 14.50 | 540 | 6 | 6 |
2 | 2003.76 | 62 | 12.36 | 2958 | 6 | 6 |
3 | 1557.16 | 25 | 13.15 | 2436 | 6 | 6 |
4 | 868.92 | 25 | 13.59 | 1618 | 6 | 6 |
5 | 179.12 | 25 | 14.20 | 742 | 6 | 6 |
6 | 89.12 | 25 | 14.33 | 598 | 6 | 6 |
7 | 46.48 | 25 | 14.37 | 526 | 6 | 6 |
8 | 0.04 | 251 | 14.08 | 436 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.32 | 29 | 14.43 | 560 | 6 | 6 |
2 | 2002.44 | 62 | 12.37 | 2956 | 6 | 6 |
3 | 1361.04 | 25 | 13.26 | 2218 | 6 | 6 |
4 | 918.24 | 25 | 13.54 | 1684 | 6 | 6 |
5 | 221.52 | 25 | 14.18 | 780 | 6 | 6 |
6 | 59.92 | 25 | 14.39 | 566 | 6 | 6 |
7 | 36.00 | 25 | 14.34 | 504 | 6 | 6 |
8 | 0.08 | 24 | 14.40 | 452 | 6 | 6 |
9 | -0.00 | 251 | 14.02 | 435 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.76 | 29 | 14.50 | 540 | 6 | 6 |
2 | 2002.84 | 62 | 12.39 | 2950 | 6 | 6 |
3 | 1345.12 | 25 | 13.26 | 2212 | 6 | 6 |
4 | 887.52 | 25 | 13.60 | 1640 | 6 | 6 |
5 | 180.12 | 25 | 14.22 | 742 | 6 | 6 |
6 | 50.68 | 25 | 14.39 | 558 | 6 | 6 |
7 | 31.48 | 25 | 14.36 | 496 | 6 | 6 |
8 | -0.00 | 24 | 14.41 | 456 | 6 | 6 |
9 | 0.04 | 251 | 14.02 | 432 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.52 | 29 | 14.50 | 540 | 6 | 6 |
2 | 2002.12 | 62 | 12.37 | 2966 | 6 | 6 |
3 | 1551.96 | 25 | 13.16 | 2442 | 6 | 6 |
4 | 860.80 | 25 | 13.60 | 1596 | 6 | 6 |
5 | 172.80 | 25 | 14.25 | 716 | 6 | 6 |
6 | 48.08 | 25 | 14.41 | 538 | 6 | 6 |
7 | 30.96 | 25 | 14.34 | 504 | 6 | 6 |
8 | 0.12 | 251 | 14.07 | 443 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.64 | 29 | 14.43 | 540 | 6 | 6 |
2 | 2001.64 | 63 | 12.37 | 2948 | 6 | 6 |
3 | 1538.52 | 24 | 13.13 | 2446 | 6 | 6 |
4 | 854.76 | 24 | 13.59 | 1616 | 6 | 6 |
5 | 203.28 | 24 | 14.22 | 758 | 6 | 6 |
6 | 57.00 | 24 | 14.39 | 554 | 6 | 6 |
7 | 36.12 | 24 | 14.35 | 514 | 6 | 6 |
8 | 17.32 | 24 | 14.36 | 468 | 6 | 6 |
9 | 0.04 | 251 | 14.06 | 430 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.60 | 29 | 14.43 | 560 | 6 | 6 |
2 | 2009.60 | 62 | 12.37 | 2972 | 6 | 6 |
3 | 1362.40 | 25 | 13.25 | 2202 | 6 | 6 |
4 | 912.32 | 24 | 13.59 | 1638 | 6 | 6 |
5 | 205.00 | 25 | 14.22 | 736 | 6 | 6 |
6 | 52.24 | 25 | 14.39 | 528 | 6 | 6 |
7 | 30.72 | 25 | 14.35 | 490 | 6 | 6 |
8 | 0.04 | 251 | 14.08 | 437 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 29 | 14.50 | 540 | 6 | 6 |
2 | 2001.88 | 62 | 12.39 | 2939 | 6 | 6 |
3 | 1560.76 | 25 | 13.10 | 2468 | 6 | 6 |
4 | 1067.36 | 25 | 13.46 | 1826 | 6 | 6 |
5 | 316.36 | 24 | 14.09 | 904 | 6 | 6 |
6 | 44.44 | 24 | 14.40 | 526 | 6 | 6 |
7 | 28.04 | 25 | 14.33 | 488 | 6 | 6 |
8 | -0.00 | 24 | 14.40 | 452 | 6 | 6 |
9 | -0.04 | 251 | 14.00 | 433 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.16 | 29 | 14.43 | 560 | 6 | 6 |
2 | 2003.80 | 62 | 12.35 | 2962 | 6 | 6 |
3 | 1550.28 | 25 | 13.12 | 2426 | 6 | 6 |
4 | 856.76 | 25 | 13.60 | 1602 | 6 | 6 |
5 | 181.28 | 24 | 14.26 | 716 | 6 | 6 |
6 | 49.40 | 24 | 14.40 | 540 | 6 | 6 |
7 | 31.20 | 24 | 14.36 | 492 | 6 | 6 |
8 | 0.04 | 24 | 14.46 | 442 | 6 | 6 |
9 | 0.04 | 251 | 14.06 | 426 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.32 | 29 | 14.50 | 560 | 6 | 6 |
2 | 2001.12 | 62 | 12.36 | 2950 | 6 | 6 |
3 | 1345.04 | 25 | 13.23 | 2204 | 6 | 6 |
4 | 892.00 | 25 | 13.57 | 1636 | 6 | 6 |
5 | 181.80 | 25 | 14.25 | 732 | 6 | 6 |
6 | 46.12 | 25 | 14.39 | 536 | 6 | 6 |
7 | 31.84 | 25 | 14.34 | 498 | 6 | 6 |
8 | -0.00 | 251 | 14.08 | 435 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.84 | 29 | 14.50 | 560 | 6 | 6 |
2 | 2003.20 | 62 | 12.35 | 2940 | 6 | 6 |
3 | 1540.56 | 25 | 13.09 | 2434 | 6 | 6 |
4 | 857.32 | 25 | 13.59 | 1598 | 6 | 6 |
5 | 165.12 | 24 | 14.26 | 710 | 6 | 6 |
6 | 39.92 | 25 | 14.38 | 538 | 6 | 6 |
7 | 25.40 | 25 | 14.30 | 502 | 6 | 6 |
8 | -0.00 | 24 | 14.41 | 466 | 6 | 6 |
9 | -0.04 | 251 | 14.01 | 439 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.44 | 29 | 14.43 | 580 | 6 | 6 |
2 | 2003.84 | 62 | 12.35 | 2943 | 6 | 6 |
3 | 1552.76 | 24 | 13.10 | 2432 | 6 | 6 |
4 | 864.24 | 24 | 13.58 | 1598 | 6 | 6 |
5 | 178.96 | 25 | 14.26 | 718 | 6 | 6 |
6 | 41.32 | 25 | 14.41 | 522 | 6 | 6 |
7 | 25.48 | 25 | 14.35 | 488 | 6 | 6 |
8 | 0.04 | 24 | 14.43 | 454 | 6 | 6 |
9 | -0.00 | 251 | 14.02 | 437 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.12 | 29 | 14.50 | 540 | 6 | 6 |
2 | 2003.12 | 62 | 12.36 | 2946 | 6 | 6 |
3 | 1359.52 | 25 | 13.24 | 2204 | 6 | 6 |
4 | 910.76 | 24 | 13.55 | 1650 | 6 | 6 |
5 | 208.56 | 24 | 14.23 | 734 | 6 | 6 |
6 | 47.08 | 24 | 14.42 | 510 | 6 | 6 |
7 | 26.68 | 24 | 14.37 | 484 | 6 | 6 |
8 | -0.08 | 25 | 14.42 | 448 | 6 | 6 |
9 | -0.04 | 250 | 14.03 | 430 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.12 | 29 | 14.50 | 540 | 6 | 6 |
2 | 2003.00 | 62 | 12.41 | 2935 | 6 | 6 |
3 | 1559.96 | 25 | 13.11 | 2448 | 6 | 6 |
4 | 863.56 | 24 | 13.60 | 1592 | 6 | 6 |
5 | 175.52 | 24 | 14.28 | 684 | 6 | 6 |
6 | 47.64 | 24 | 14.46 | 504 | 6 | 6 |
7 | 27.64 | 25 | 14.37 | 472 | 6 | 6 |
8 | 0.12 | 24 | 14.47 | 434 | 6 | 6 |
9 | 0.04 | 251 | 14.05 | 427 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.56 | 29 | 14.50 | 560 | 6 | 6 |
2 | 2001.64 | 62 | 12.42 | 2966 | 6 | 6 |
3 | 1541.60 | 24 | 13.12 | 2440 | 6 | 6 |
4 | 848.24 | 24 | 13.61 | 1582 | 6 | 6 |
5 | 374.72 | 24 | 14.04 | 976 | 6 | 6 |
6 | 64.56 | 24 | 14.40 | 546 | 6 | 6 |
7 | 37.52 | 25 | 14.39 | 490 | 6 | 6 |
8 | 0.08 | 24 | 14.47 | 440 | 6 | 6 |
9 | 0.04 | 251 | 14.06 | 424 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.36 | 29 | 14.50 | 560 | 6 | 6 |
2 | 2003.08 | 62 | 12.46 | 2968 | 6 | 6 |
3 | 1329.76 | 25 | 13.26 | 2170 | 6 | 6 |
4 | 677.00 | 24 | 13.75 | 1366 | 6 | 6 |
5 | 222.44 | 25 | 14.19 | 772 | 6 | 6 |
6 | 53.20 | 24 | 14.44 | 528 | 6 | 6 |
7 | 31.52 | 25 | 14.37 | 488 | 6 | 6 |
8 | -0.08 | 24 | 14.48 | 438 | 6 | 6 |
9 | -0.16 | 251 | 14.06 | 428 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 28 | 14.56 | 540 | 6 | 6 |
2 | 2001.96 | 62 | 12.50 | 2958 | 6 | 6 |
3 | 1548.92 | 24 | 13.14 | 2442 | 6 | 6 |
4 | 853.44 | 24 | 13.60 | 1598 | 6 | 6 |
5 | 167.44 | 24 | 14.28 | 696 | 6 | 6 |
6 | 54.68 | 25 | 14.44 | 520 | 6 | 6 |
7 | 33.60 | 24 | 14.39 | 486 | 6 | 6 |
8 | -0.04 | 251 | 14.12 | 425 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.56 | 28 | 14.50 | 560 | 6 | 6 |
2 | 2002.88 | 62 | 12.53 | 2968 | 6 | 6 |
3 | 1548.16 | 25 | 13.12 | 2438 | 6 | 6 |
4 | 852.00 | 24 | 13.60 | 1566 | 6 | 6 |
5 | 175.72 | 24 | 14.30 | 672 | 6 | 6 |
6 | 58.84 | 24 | 14.48 | 504 | 6 | 6 |
7 | 32.72 | 25 | 14.44 | 462 | 6 | 6 |
8 | 0.04 | 24 | 14.52 | 414 | 6 | 6 |
9 | 0.04 | 251 | 14.10 | 401 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.28 | 28 | 14.56 | 520 | 6 | 6 |
2 | 2001.56 | 62 | 12.55 | 2951 | 6 | 6 |
3 | 1327.64 | 25 | 13.24 | 2160 | 6 | 6 |
4 | 872.36 | 24 | 13.57 | 1600 | 6 | 6 |
5 | 163.52 | 25 | 14.28 | 692 | 6 | 6 |
6 | 49.96 | 25 | 14.44 | 520 | 6 | 6 |
7 | 26.80 | 24 | 14.41 | 470 | 6 | 6 |
8 | 0.16 | 24 | 14.48 | 432 | 6 | 6 |
9 | -0.04 | 251 | 14.05 | 420 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.68 | 27 | 14.56 | 540 | 6 | 6 |
2 | 2001.80 | 62 | 12.55 | 2980 | 6 | 6 |
3 | 1536.04 | 24 | 13.12 | 2408 | 6 | 6 |
4 | 845.04 | 25 | 13.61 | 1546 | 6 | 6 |
5 | 176.76 | 25 | 14.28 | 670 | 6 | 6 |
6 | 51.00 | 25 | 14.49 | 480 | 6 | 6 |
7 | 28.32 | 25 | 14.43 | 438 | 6 | 6 |
8 | 0.04 | 24 | 14.51 | 398 | 6 | 6 |
9 | -0.00 | 251 | 14.09 | 385 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.76 | 27 | 14.56 | 540 | 6 | 6 |
2 | 2003.76 | 62 | 12.55 | 2964 | 6 | 6 |
3 | 1322.96 | 24 | 13.22 | 2160 | 6 | 6 |
4 | 868.52 | 24 | 13.53 | 1600 | 6 | 6 |
5 | 166.04 | 25 | 14.27 | 682 | 6 | 6 |
6 | 48.32 | 25 | 14.45 | 510 | 6 | 6 |
7 | 28.60 | 24 | 14.39 | 468 | 6 | 6 |
8 | -0.00 | 24 | 14.48 | 428 | 6 | 6 |
9 | -0.04 | 251 | 14.04 | 417 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.60 | 29 | 14.56 | 560 | 6 | 6 |
2 | 936.12 | -1 | 14.56 | 560 | 6 | 6 |
3 | 2002.16 | 62 | 12.51 | 2963 | 6 | 6 |
4 | 1338.80 | 25 | 13.19 | 2174 | 6 | 6 |
5 | 668.00 | 24 | 13.69 | 1346 | 6 | 6 |
6 | 106.36 | 25 | 14.35 | 592 | 6 | 6 |
7 | 52.32 | 25 | 14.39 | 510 | 6 | 6 |
8 | 26.00 | 25 | 14.35 | 468 | 6 | 6 |
9 | 0.04 | 24 | 14.44 | 430 | 6 | 6 |
10 | -0.00 | 251 | 13.99 | 414 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 28 | 14.50 | 560 | 6 | 6 |
2 | 1503.12 | 62 | 12.95 | 2360 | 6 | 6 |
3 | 1288.36 | 25 | 13.24 | 2106 | 6 | 6 |
4 | 591.40 | 25 | 13.76 | 1246 | 6 | 6 |
5 | 68.72 | 25 | 14.42 | 548 | 6 | 6 |
6 | 38.68 | 25 | 14.37 | 500 | 6 | 6 |
7 | 0.08 | 25 | 14.52 | 436 | 6 | 6 |
8 | -0.00 | 251 | 13.99 | 418 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.60 | 28 | 14.43 | 560 | 6 | 6 |
2 | 1501.00 | 62 | 12.91 | 2360 | 6 | 6 |
3 | 1283.16 | 25 | 13.20 | 2124 | 6 | 6 |
4 | 571.76 | 25 | 13.77 | 1228 | 6 | 6 |
5 | 66.64 | 25 | 14.40 | 556 | 6 | 6 |
6 | 37.16 | 25 | 14.33 | 506 | 6 | 6 |
7 | 0.04 | 251 | 13.97 | 435 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.12 | 28 | 14.37 | 580 | 6 | 6 |
2 | 1504.40 | 62 | 12.78 | 2388 | 6 | 6 |
3 | 1295.52 | 25 | 13.09 | 2144 | 6 | 6 |
4 | 595.16 | 25 | 13.64 | 1282 | 6 | 6 |
5 | 76.04 | 25 | 14.32 | 584 | 6 | 6 |
6 | 42.40 | 25 | 14.30 | 520 | 6 | 6 |
7 | 0.04 | 24 | 14.46 | 460 | 6 | 6 |
8 | -0.04 | 251 | 13.92 | 435 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 27 | 14.43 | 540 | 7 | 7 |
2 | 997.32 | 63 | 13.00 | 1767 | 7 | 6 |
3 | 121.24 | 24 | 14.15 | 658 | 6 | 6 |
4 | 56.40 | 24 | 14.23 | 568 | 6 | 6 |
5 | 28.92 | 24 | 14.22 | 520 | 6 | 6 |
6 | -0.00 | 24 | 14.32 | 472 | 6 | 6 |
7 | 0.04 | 251 | 13.85 | 447 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 123.84 | 62 | 13.96 | 545 | 176 | 7 |
2 | 103.84 | 25 | 14.39 | 542 | 7 | 7 |
3 | 65.64 | 24 | 14.42 | 500 | 7 | 7 |
4 | 38.56 | 25 | 14.45 | 460 | 6 | 7 |
5 | 0.08 | 24 | 14.61 | 406 | 7 | 7 |
6 | 0.04 | 250 | 14.16 | 387 | 7 | 10 |