SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8595 WMO= 4903007


Cycle 254 GMT 22/12/2024 3:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 32 14.88 491 2 2
2 3 905.20 -2 15.34 0 2 2
3 3 970.88 -1 15.37 0 2 2
4 12 1130.48 2 15.04 2013 2 2
5 7 2004.80 40 14.46 3100 2 2
6 13 1737.56 19 14.48 2785 2 2
7 13 1190.64 19 14.55 2037 2 2
8 13 608.92 19 14.72 1236 2 2
9 13 189.28 19 14.87 639 2 2
10 8 0.04 170 14.91 335 2 2

Cycle 253 GMT 12/12/2024 2:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 14.88 475 2 2
2 10 1019.48 2 14.88 1888 2 2
3 3 1096.84 2 14.88 2020 2 2
4 3 1081.08 2 14.91 2001 2 2
5 5 1321.04 8 14.80 2355 2 2
6 5 1375.96 9 14.77 2415 2 2
7 12 1342.44 2 14.94 2343 2 2
8 7 2007.20 40 14.45 3114 2 2
9 13 1877.20 19 14.45 2970 2 2
10 13 1016.76 19 14.62 1792 2 2
11 13 603.28 19 14.73 1232 2 2
12 13 173.12 19 14.88 619 2 2
13 8 0.16 170 14.91 343 2 3

Cycle 252 GMT 2/12/2024 3:14: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 30 14.88 484 2 2
2 12 1114.68 2 15.04 1987 2 2
3 7 2004.28 40 14.48 3080 2 2
4 13 1733.88 19 14.50 2742 2 2
5 13 1291.88 19 14.53 2166 2 2
6 13 713.56 19 14.69 1384 2 2
7 13 138.20 19 14.90 560 2 2
8 8 0.08 170 14.91 332 2 3

Cycle 251 GMT 22/11/2024 3: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 30 14.89 471 2 2
2 12 1106.80 2 15.03 1990 2 2
3 7 2003.48 41 14.46 3105 2 2
4 13 1617.40 19 14.49 2638 2 2
5 13 1058.08 19 14.60 1844 2 2
6 13 510.68 19 14.76 1097 2 2
7 13 117.44 19 14.91 525 2 2
8 13 25.40 19 14.94 379 2 2
9 8 -0.08 170 14.90 339 2 3

Cycle 250 GMT 12/11/2024 2:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 30 14.88 479 2 2
2 12 1125.32 2 15.03 2024 2 2
3 7 2001.32 40 14.47 3094 2 2
4 13 1729.56 19 14.49 2766 2 2
5 13 1031.36 19 14.61 1804 2 2
6 13 746.28 19 14.68 1427 2 2
7 13 151.72 19 14.89 575 2 2
8 8 0.08 170 14.91 336 2 3

Cycle 249 GMT 2/11/2024 2:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 30 14.89 475 2 2
2 12 1120.00 2 15.03 2008 2 2
3 7 2001.52 40 14.47 3106 2 2
4 13 1583.24 19 14.51 2589 2 2
5 13 1162.44 19 14.57 1990 2 2
6 13 567.36 19 14.75 1163 2 2
7 13 139.64 19 14.90 561 2 2
8 8 0.08 170 14.91 333 2 3

Cycle 248 GMT 23/10/2024 3:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 30 14.88 479 2 2
2 12 1108.36 2 15.04 1991 2 2
3 7 2001.72 40 14.47 3097 2 2
4 13 1598.52 19 14.51 2609 2 2
5 13 1331.36 19 14.52 2230 2 2
6 13 594.00 19 14.74 1212 2 2
7 13 88.52 19 14.93 473 2 2
8 13 22.12 19 14.95 365 2 2
9 8 0.48 170 14.91 325 2 2
10 14 0.48 30 14.89 327 2 3

Cycle 247 GMT 13/10/2024 3:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.89 470 2 2
2 12 1113.92 2 15.05 1989 2 2
3 7 2002.56 40 14.47 3092 2 2
4 13 1594.64 19 14.51 2583 2 2
5 13 1032.12 19 14.61 1813 2 2
6 13 491.08 19 14.77 1067 2 2
7 13 109.52 19 14.91 513 2 2
8 13 25.64 19 14.94 382 2 2
9 8 -0.04 170 14.91 328 2 3

Cycle 246 GMT 3/10/2024 2:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 30 14.90 485 2 2
2 12 1125.24 2 15.03 2013 2 2
3 7 2004.28 40 14.47 3101 2 2
4 13 1726.68 19 14.49 2774 2 2
5 13 1158.64 19 14.58 1987 2 2
6 13 584.84 19 14.75 1193 2 2
7 13 166.12 19 14.90 598 2 2
8 13 17.84 19 14.95 362 2 2
9 8 0.00 170 14.91 331 2 3

Cycle 245 GMT 23/ 9/2024 2:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 14.89 468 2 2
2 10 1002.48 2 14.89 1868 2 2
3 12 1128.56 2 15.03 2014 2 2
4 7 2005.24 40 14.47 3075 2 2
5 13 1732.52 19 14.49 2757 2 2
6 13 1152.48 19 14.59 1963 2 2
7 13 719.00 19 14.70 1384 2 2
8 13 139.44 19 14.91 557 2 2
9 13 28.68 19 14.94 384 2 2
10 8 -0.08 170 14.91 326 2 3

Cycle 244 GMT 13/ 9/2024 2:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 30 14.89 477 2 2
2 12 1122.24 2 15.03 2013 2 2
3 7 2002.76 40 14.48 3107 2 2
4 13 1605.28 19 14.52 2602 2 2
5 13 930.76 19 14.65 1667 2 2
6 13 527.48 19 14.77 1118 2 2
7 13 125.48 19 14.91 532 2 2
8 13 13.40 19 14.95 356 2 2
9 8 0.04 170 14.91 327 2 3

Cycle 243 GMT 3/ 9/2024 2:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 30 14.90 474 2 2
2 12 1134.08 2 15.03 2029 2 2
3 7 2004.88 40 14.47 3107 2 2
4 13 1743.00 19 14.49 2785 2 2
5 13 1162.64 19 14.58 2000 2 2
6 13 592.16 19 14.74 1208 2 2
7 13 170.80 19 14.90 609 2 2
8 13 18.84 19 14.95 370 2 2
9 8 -0.08 170 14.91 336 2 3

Cycle 242 GMT 24/ 8/2024 2:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 30 14.90 484 2 2
2 12 1120.80 2 15.03 2016 2 2
3 7 2003.20 40 14.47 3092 2 2
4 13 1871.68 19 14.46 2963 2 2
5 13 1033.64 19 14.62 1809 2 2
6 13 621.40 19 14.73 1247 2 2
7 13 113.68 19 14.92 516 2 2
8 13 26.28 19 14.95 381 2 2
9 8 0.08 170 14.91 330 2 3

Cycle 241 GMT 14/ 8/2024 2:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 30 14.89 483 2 2
2 12 1110.16 2 15.04 1959 2 2
3 7 2004.16 40 14.46 3113 2 2
4 13 1737.28 19 14.48 2794 2 2
5 13 1170.60 19 14.57 2007 2 2
6 13 604.68 19 14.73 1229 2 2
7 13 175.72 19 14.90 611 2 2
8 13 19.36 19 14.95 370 2 2
9 8 0.00 170 14.92 328 2 3

Cycle 240 GMT 4/ 8/2024 2: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 30 14.89 505 2 2
2 12 1105.24 2 15.04 1984 2 2
3 7 2004.20 40 14.47 3109 2 2
4 13 1600.84 19 14.51 2595 2 2
5 13 1331.04 19 14.52 2230 2 2
6 13 570.12 19 14.75 1178 2 2
7 13 150.04 19 14.91 577 2 2
8 13 18.40 19 14.95 367 2 2
9 8 0.00 170 14.91 339 2 3

Cycle 239 GMT 25/ 7/2024 1:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 14.89 479 2 2
2 3 1021.12 1 15.01 1868 2 2
3 12 1230.24 2 14.99 2181 2 2
4 7 2003.56 40 14.46 3080 2 2
5 13 1872.76 19 14.46 2955 2 2
6 13 1276.60 19 14.55 2147 2 2
7 13 680.76 19 14.71 1335 2 2
8 13 127.76 19 14.92 542 2 2
9 13 27.20 19 14.95 385 2 2
10 8 0.00 170 14.91 338 2 2

Cycle 238 GMT 15/ 7/2024 1:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 29 14.90 496 2 2
2 3 1060.64 2 14.93 1919 2 2
3 12 1118.56 2 15.03 2007 2 2
4 7 2004.96 40 14.47 3078 2 2
5 13 1591.76 19 14.51 2551 2 2
6 13 1174.00 19 14.56 2014 2 2
7 13 599.04 19 14.73 1228 2 2
8 13 168.48 19 14.90 598 2 2
9 13 16.60 19 14.95 366 2 2
10 8 0.04 170 14.91 339 2 3

Cycle 237 GMT 5/ 7/2024 1:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 29 14.89 477 2 2
2 12 1134.20 2 15.04 1986 2 2
3 7 2004.40 40 14.47 3092 2 2
4 13 1610.16 19 14.50 2612 2 2
5 13 1049.04 19 14.61 1825 2 2
6 13 491.52 19 14.78 1060 2 2
7 13 110.24 19 14.92 504 2 2
8 8 -0.04 170 14.92 331 2 3

Cycle 236 GMT 25/ 6/2024 1:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 29 14.89 480 2 2
2 12 1243.28 2 14.99 2168 2 2
3 7 2006.80 40 14.46 3088 2 2
4 13 1475.24 19 14.53 2414 2 2
5 13 1066.88 19 14.60 1848 2 2
6 13 636.88 19 14.72 1267 2 2
7 13 111.92 19 14.92 507 2 2
8 8 0.08 170 14.92 327 2 2

Cycle 235 GMT 15/ 6/2024 1:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 14.89 490 2 2
2 12 1131.60 2 15.03 2020 2 2
3 7 2006.60 40 14.46 3092 2 2
4 13 1601.56 19 14.50 2601 2 2
5 13 1054.28 19 14.61 1834 2 2
6 13 508.44 19 14.77 1082 2 2
7 13 121.08 19 14.91 521 2 2
8 8 0.16 170 14.92 333 2 3

Cycle 234 GMT 5/ 6/2024 1:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 29 14.88 488 2 2
2 12 1131.76 2 15.03 2009 2 2
3 7 2006.08 40 14.46 3097 2 2
4 13 1743.24 19 14.47 2782 2 2
5 13 1170.56 19 14.57 1990 2 2
6 13 610.20 19 14.73 1238 2 2
7 13 98.16 19 14.92 489 2 2
8 8 0.24 170 14.92 337 2 4

Cycle 233 GMT 26/ 5/2024 1: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 29 14.88 470 2 2
2 12 1240.92 2 14.97 2179 2 2
3 7 2004.76 40 14.45 3095 2 2
4 13 1739.72 19 14.46 2776 2 2
5 13 1170.96 19 14.56 1993 2 2
6 13 609.24 19 14.73 1233 2 2
7 13 172.32 19 14.88 611 2 2
8 8 0.08 170 14.91 335 2 3

Cycle 232 GMT 16/ 5/2024 1: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 29 14.88 488 2 2
2 3 1033.16 1 14.93 1888 2 2
3 12 1134.24 2 15.00 2021 2 2
4 7 2006.92 40 14.46 3086 2 2
5 13 1741.88 19 14.47 2791 2 2
6 13 1041.04 19 14.60 1824 2 2
7 13 504.32 19 14.76 1085 2 2
8 13 116.24 19 14.91 519 2 2
9 8 0.04 170 14.91 331 2 3

Cycle 231 GMT 6/ 5/2024 1: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 14.87 484 2 2
2 12 1119.76 2 15.02 1998 2 2
3 7 2002.04 40 14.45 3107 2 2
4 13 1735.24 19 14.47 2780 2 2
5 13 1167.88 19 14.56 1994 2 2
6 13 589.92 19 14.73 1206 2 2
7 13 165.80 19 14.88 602 2 2
8 8 0.12 170 14.91 332 2 3

Cycle 230 GMT 26/ 4/2024 1:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 29 14.87 485 2 2
2 12 1124.12 2 15.03 1999 2 2
3 7 2002.24 40 14.45 3101 2 2
4 13 1732.48 19 14.46 2773 2 2
5 13 1032.24 19 14.60 1807 2 2
6 13 608.16 19 14.72 1226 2 2
7 13 170.28 19 14.87 608 2 2
8 8 0.16 170 14.90 335 2 2

Cycle 229 GMT 16/ 4/2024 1: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 29 14.87 476 2 2
2 12 1242.40 2 14.98 2193 2 2
3 7 2003.04 40 14.45 3105 2 2
4 13 1738.72 19 14.47 2787 2 2
5 13 1162.84 19 14.56 1988 2 2
6 13 584.04 19 14.73 1196 2 2
7 13 163.12 19 14.88 602 2 2
8 8 0.00 170 14.90 334 2 2

Cycle 228 GMT 6/ 4/2024 0:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 29 14.87 492 2 2
2 3 1036.24 1 14.92 1898 2 2
3 12 1238.88 2 14.99 2148 2 2
4 7 2003.92 40 14.46 3074 2 2
5 13 1746.64 19 14.46 2790 2 2
6 13 1199.20 19 14.54 2035 2 2
7 13 631.24 19 14.70 1264 2 2
8 13 200.72 19 14.86 651 2 2
9 8 0.24 170 14.90 333 2 5

Cycle 227 GMT 27/ 3/2024 0:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 29 14.87 500 2 2
2 12 1134.80 2 15.01 2020 2 2
3 7 2002.44 40 14.46 3094 2 2
4 13 1604.20 19 14.48 2614 2 2
5 13 1191.20 19 14.55 2024 2 2
6 13 742.92 19 14.66 1413 2 2
7 13 150.16 19 14.88 576 2 2
8 8 0.12 170 14.89 339 2 3

Cycle 226 GMT 17/ 3/2024 0:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 29 14.87 489 2 2
2 12 1125.48 2 15.02 2010 2 2
3 7 2002.28 40 14.45 3077 2 2
4 13 1738.60 19 14.46 2793 2 2
5 13 1044.88 19 14.59 1824 2 2
6 13 621.80 19 14.71 1252 2 2
7 13 102.72 19 14.90 495 2 2
8 8 0.00 170 14.90 337 2 4

Cycle 225 GMT 7/ 3/2024 0:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.86 482 2 2
2 3 1023.04 1 14.96 1845 2 2
3 12 1117.36 2 15.01 2009 2 2
4 7 2007.48 40 14.45 3097 2 2
5 13 1876.80 19 14.44 2964 2 2
6 13 1141.52 19 14.56 1957 2 2
7 13 582.52 19 14.72 1193 2 2
8 13 163.60 19 14.87 594 2 2
9 8 0.12 170 14.89 335 2 3

Cycle 224 GMT 26/ 2/2024 0:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 14.87 470 2 2
2 12 1119.44 2 15.02 2007 2 2
3 7 2003.08 40 14.45 3102 2 2
4 13 1598.96 19 14.48 2609 2 2
5 13 1173.92 19 14.54 2014 2 2
6 13 600.88 19 14.70 1228 2 2
7 13 88.32 19 14.89 485 2 2
8 8 0.24 170 14.89 336 2 3

Cycle 223 GMT 16/ 2/2024 0:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 29 14.86 490 2 2
2 12 1122.72 2 15.01 2002 2 2
3 7 2003.96 40 14.45 3110 2 2
4 13 1872.60 19 14.44 2970 2 2
5 13 1143.88 19 14.55 1969 2 2
6 13 589.64 19 14.71 1214 2 2
7 13 164.40 19 14.87 598 2 2
8 8 -0.08 170 14.89 331 2 3

Cycle 222 GMT 6/ 2/2024 0:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 29 14.87 467 2 2
2 12 1242.64 2 14.99 2153 2 2
3 7 2002.00 40 14.47 3060 2 2
4 13 1730.52 19 14.47 2767 2 2
5 13 1167.96 19 14.55 1985 2 2
6 13 592.04 19 14.71 1207 2 2
7 13 165.68 19 14.87 596 2 2
8 8 0.32 170 14.89 331 2 2

Cycle 221 GMT 27/ 1/2024 0:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 29 14.86 498 2 2
2 12 1222.96 2 14.98 2139 2 2
3 7 2006.84 40 14.45 3071 2 2
4 13 1737.00 19 14.46 2756 2 2
5 13 1165.32 19 14.54 1998 2 2
6 13 594.28 19 14.71 1204 2 2
7 13 89.56 19 14.90 468 2 2
8 8 0.04 170 14.89 332 2 3

Cycle 220 GMT 16/ 1/2024 23:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 29 14.87 481 2 2
2 12 1135.32 2 15.01 1996 2 2
3 7 2008.16 40 14.45 3111 2 2
4 13 1878.28 19 14.44 2969 2 2
5 13 1018.68 19 14.59 1782 2 2
6 13 614.08 19 14.70 1234 2 2
7 13 185.36 19 14.85 629 2 2
8 8 -0.16 170 14.89 329 2 3

Cycle 219 GMT 6/ 1/2024 23:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 14.88 471 2 2
2 12 1130.28 2 15.01 2012 2 2
3 7 2006.12 40 14.45 3101 2 2
4 13 1739.92 19 14.46 2788 2 2
5 13 1028.04 19 14.59 1802 2 2
6 13 608.40 19 14.70 1229 2 2
7 13 98.32 19 14.89 490 2 2
8 8 0.24 170 14.89 333 2 3

Cycle 218 GMT 27/12/2023 23:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 14.88 471 2 2
2 12 1134.08 2 15.01 2028 2 2
3 7 2002.52 40 14.46 3072 2 2
4 13 1592.40 19 14.49 2589 2 2
5 13 1041.80 19 14.59 1810 2 2
6 13 628.64 19 14.70 1254 2 2
7 13 106.04 19 14.89 499 2 2
8 8 -0.04 170 14.89 330 2 5

Cycle 217 GMT 17/12/2023 23:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 14.87 490 2 2
2 12 1118.20 2 15.01 1994 2 2
3 7 2006.92 41 14.44 3107 2 2
4 13 1741.16 19 14.46 2788 2 2
5 13 1163.04 19 14.55 1980 2 2
6 13 591.32 19 14.71 1203 2 2
7 13 165.52 19 14.86 594 2 2
8 8 -0.04 170 14.89 326 2 2

Cycle 216 GMT 7/12/2023 22:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 29 14.87 490 2 2
2 12 1119.56 2 15.01 1986 2 2
3 7 2007.88 40 14.46 3086 2 2
4 13 1739.32 19 14.46 2796 2 2
5 13 1305.96 19 14.50 2184 2 2
6 13 577.12 19 14.72 1183 2 2
7 13 160.16 19 14.87 585 2 2
8 8 0.04 170 14.89 327 2 4

Cycle 215 GMT 27/11/2023 22:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 29 14.87 483 2 2
2 12 1129.76 2 15.01 2016 2 2
3 7 2003.84 40 14.46 3079 2 2
4 13 1740.04 19 14.46 2792 2 2
5 13 1283.60 19 14.52 2161 2 2
6 13 564.08 19 14.72 1166 2 2
7 13 151.12 19 14.87 568 2 2
8 8 0.08 170 14.89 324 2 2

Cycle 214 GMT 17/11/2023 22:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 29 14.88 463 2 2
2 12 1120.76 2 15.01 2003 2 2
3 7 2004.24 40 14.45 3093 2 2
4 13 1744.80 19 14.47 2797 2 2
5 13 1310.76 19 14.51 2194 2 2
6 13 718.92 19 14.66 1387 2 2
7 13 150.80 19 14.87 562 2 2
8 13 35.72 19 14.92 375 2 2
9 8 -0.08 170 14.88 325 2 3

Cycle 213 GMT 7/11/2023 22:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 29 14.87 472 2 2
2 12 1129.96 2 15.02 2009 2 2
3 7 2005.64 40 14.46 3075 2 2
4 13 1747.76 19 14.46 2798 2 2
5 13 1469.40 19 14.45 2426 2 2
6 13 579.60 19 14.71 1187 2 2
7 13 163.48 19 14.87 589 2 2
8 8 0.08 170 14.89 330 2 2

Cycle 212 GMT 28/10/2023 22: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.87 472 2 2
2 12 1132.44 2 15.00 2019 2 2
3 7 2004.52 40 14.45 3080 2 2
4 13 1741.12 19 14.46 2787 2 2
5 13 1028.72 19 14.58 1797 2 2
6 13 596.28 19 14.70 1212 2 2
7 13 163.56 19 14.86 592 2 2
8 8 0.08 170 14.89 323 2 3

Cycle 211 GMT 18/10/2023 21:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 29 14.88 460 2 2
2 12 1126.72 2 15.02 2000 2 2
3 7 2003.00 40 14.45 3103 2 2
4 13 1734.04 19 14.46 2775 2 2
5 13 1035.08 19 14.59 1813 2 2
6 13 491.40 19 14.74 1069 2 2
7 13 116.64 19 14.89 514 2 2
8 8 0.08 170 14.89 325 2 3

Cycle 210 GMT 8/10/2023 21:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 29 14.87 468 2 2
2 12 1118.00 2 15.01 2001 2 2
3 7 2003.80 40 14.46 3106 2 2
4 13 1599.00 19 14.49 2612 2 2
5 13 1046.72 19 14.58 1833 2 2
6 13 496.80 19 14.74 1071 2 2
7 13 122.08 19 14.88 522 2 2
8 8 -0.08 170 14.89 329 2 3

Cycle 209 GMT 28/ 9/2023 21: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 29 14.87 462 2 2
2 12 1142.16 2 15.01 2051 2 2
3 7 2004.52 40 14.45 3107 2 2
4 13 1733.00 19 14.47 2778 2 2
5 13 1159.84 19 14.55 1980 2 2
6 13 595.92 19 14.70 1212 2 2
7 13 175.92 19 14.85 617 2 2
8 13 18.88 19 14.91 359 2 2
9 8 0.08 170 14.88 327 2 2

Cycle 208 GMT 18/ 9/2023 20:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 14.87 467 2 2
2 12 1134.44 2 15.01 2031 2 2
3 7 2003.68 40 14.45 3101 2 2
4 13 1742.72 19 14.46 2780 2 2
5 13 1040.36 19 14.58 1822 2 2
6 13 488.32 19 14.74 1055 2 2
7 13 118.36 19 14.88 519 2 2
8 13 27.32 19 14.91 375 2 2
9 8 0.08 170 14.88 328 2 2

Cycle 207 GMT 8/ 9/2023 20:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 14.87 468 2 2
2 12 1129.92 2 15.04 1988 2 2
3 7 2002.04 40 14.45 3104 2 2
4 13 1744.28 19 14.47 2779 2 2
5 13 1163.12 19 14.55 1985 2 2
6 13 583.64 19 14.70 1197 2 2
7 13 155.92 19 14.87 578 2 2
8 8 -0.04 170 14.89 330 2 3

Cycle 206 GMT 29/ 8/2023 20:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 14.87 456 2 2
2 12 1132.36 2 15.02 2026 2 2
3 7 2004.92 40 14.46 3105 2 2
4 13 1873.28 19 14.45 2957 2 2
5 13 1283.48 19 14.52 2145 2 2
6 13 700.84 19 14.67 1354 2 2
7 13 139.76 19 14.87 551 2 2
8 13 15.16 19 14.92 351 2 2
9 8 0.08 170 14.88 325 2 4

Cycle 205 GMT 19/ 8/2023 20:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 29 14.88 455 2 2
2 3 1018.48 1 15.01 1860 2 2
3 12 1233.28 2 14.98 2158 2 2
4 7 2003.04 40 14.47 3065 2 2
5 13 1877.16 19 14.45 2969 2 2
6 13 1130.76 19 14.57 1932 2 2
7 13 577.64 19 14.71 1185 2 2
8 13 165.52 19 14.86 599 2 2
9 13 18.88 19 14.91 361 2 2
10 8 0.12 170 14.89 319 2 3

Cycle 204 GMT 9/ 8/2023 20:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 14.87 465 2 2
2 12 1127.64 2 15.04 1994 2 2
3 7 2002.80 40 14.47 3092 2 2
4 13 1605.72 19 14.50 2599 2 2
5 13 1195.56 19 14.54 2036 2 2
6 13 479.76 19 14.74 1045 2 2
7 13 111.36 19 14.88 509 2 2
8 13 23.28 19 14.91 369 2 2
9 8 0.04 170 14.88 324 2 3

Cycle 203 GMT 30/ 7/2023 19:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 29 14.88 455 2 2
2 12 1128.56 2 15.02 2029 2 2
3 7 2004.92 40 14.46 3111 2 2
4 13 1744.64 19 14.47 2784 2 2
5 13 1051.24 19 14.58 1835 2 2
6 13 617.68 19 14.70 1242 2 2
7 13 184.32 19 14.85 627 2 2
8 13 18.32 19 14.92 357 2 2
9 8 0.04 170 14.88 328 2 3

Cycle 202 GMT 20/ 7/2023 19:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 14.87 467 2 2
2 12 1245.56 2 14.99 2168 2 2
3 7 2001.24 40 14.46 3102 2 2
4 13 1734.68 19 14.48 2768 2 2
5 13 1026.92 19 14.59 1788 2 2
6 13 613.92 19 14.70 1230 2 2
7 13 176.24 19 14.85 610 2 2
8 8 0.12 170 14.89 328 2 3

Cycle 201 GMT 10/ 7/2023 19:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.87 478 2 2
2 12 1120.00 2 15.02 1987 2 2
3 7 2004.36 40 14.46 3094 2 2
4 13 1732.28 19 14.47 2780 2 2
5 13 1166.68 19 14.55 1988 2 2
6 13 592.60 19 14.70 1206 2 2
7 13 156.20 19 14.86 580 2 2
8 8 0.04 170 14.88 329 2 3

Cycle 200 GMT 30/ 6/2023 19:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 29 14.86 477 2 2
2 12 1123.52 2 15.03 2002 2 2
3 7 2003.52 40 14.47 3068 2 2
4 13 1614.72 19 14.51 2592 2 2
5 13 1058.84 19 14.58 1845 2 2
6 13 628.36 19 14.69 1257 2 2
7 13 107.36 19 14.89 506 2 2
8 8 0.08 170 14.89 328 2 3

Cycle 199 GMT 20/ 6/2023 19:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 29 14.86 488 2 2
2 12 1132.48 2 15.04 2006 2 2
3 7 2002.56 40 14.47 3091 2 2
4 13 1743.64 19 14.48 2810 2 2
5 13 1046.48 19 14.59 1824 2 2
6 13 613.92 19 14.69 1239 2 2
7 13 182.52 19 14.85 626 2 2
8 13 18.76 19 14.91 363 2 2
9 8 0.08 170 14.88 333 2 4

Cycle 198 GMT 10/ 6/2023 19:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 29 14.87 464 2 2
2 12 1125.96 2 15.02 2026 2 2
3 7 2003.92 40 14.46 3114 2 2
4 13 1742.36 19 14.47 2793 2 2
5 13 1155.36 19 14.56 1983 2 2
6 13 586.52 19 14.71 1195 2 2
7 13 154.00 19 14.86 584 2 2
8 8 0.04 170 14.88 337 2 2

Cycle 197 GMT 31/ 5/2023 18:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 14.87 471 2 2
2 12 1127.28 2 15.05 1990 2 2
3 7 2001.96 40 14.47 3088 2 2
4 13 1735.92 19 14.48 2775 2 2
5 13 1025.32 19 14.60 1794 2 2
6 13 597.16 19 14.70 1213 2 2
7 13 96.04 19 14.89 487 2 2
8 8 0.12 170 14.89 330 2 3

Cycle 196 GMT 21/ 5/2023 18:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 29 14.87 474 2 2
2 12 1229.84 2 15.01 2143 2 2
3 7 2004.04 40 14.47 3100 2 2
4 13 1599.84 19 14.50 2611 2 2
5 13 1044.00 19 14.59 1822 2 2
6 13 483.40 19 14.75 1053 2 2
7 13 109.00 19 14.88 523 2 2
8 8 0.16 170 14.89 332 2 3

Cycle 195 GMT 11/ 5/2023 18:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 29 14.87 475 2 2
2 12 1111.96 2 15.05 1988 2 2
3 7 2002.92 40 14.47 3071 2 2
4 13 1594.76 19 14.51 2575 2 2
5 13 1177.72 19 14.55 2007 2 2
6 13 473.88 19 14.75 1033 2 2
7 13 113.28 19 14.89 512 2 2
8 8 -0.04 170 14.89 332 2 2

Cycle 194 GMT 1/ 5/2023 18:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 29 14.86 487 2 2
2 12 1131.96 2 15.05 2006 2 2
3 7 2008.08 40 14.47 3096 2 2
4 13 1494.28 19 14.53 2453 2 2
5 13 1079.96 19 14.58 1876 2 2
6 13 524.64 19 14.73 1109 2 2
7 13 131.56 19 14.88 543 2 2
8 8 0.12 170 14.89 333 2 3

Cycle 193 GMT 21/ 4/2023 18:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 14.86 488 2 2
2 12 1224.48 2 15.01 2137 2 2
3 7 2003.52 40 14.47 3086 2 2
4 13 1598.64 19 14.50 2597 2 2
5 13 891.32 19 14.64 1614 2 2
6 13 487.84 19 14.74 1071 2 2
7 13 113.08 19 14.88 517 2 2
8 8 0.00 170 14.89 337 2 2

Cycle 192 GMT 11/ 4/2023 18:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 29 14.86 489 2 2
2 12 1228.84 2 15.00 2176 2 2
3 7 2002.40 40 14.46 3103 2 2
4 13 1725.52 19 14.49 2777 2 2
5 13 1303.92 19 14.52 2188 2 2
6 13 564.68 19 14.72 1174 2 2
7 13 136.48 19 14.87 561 2 2
8 8 0.08 170 14.88 340 2 3

Cycle 191 GMT 1/ 4/2023 17:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 29 14.86 499 2 2
2 12 1128.96 2 15.02 2042 2 2
3 7 2005.40 41 14.46 3109 2 2
4 13 1873.96 19 14.46 2964 2 2
5 13 1129.36 19 14.57 1940 2 2
6 13 554.16 19 14.72 1159 2 2
7 13 141.52 19 14.87 565 2 2
8 8 0.00 170 14.89 335 2 2

Cycle 190 GMT 22/ 3/2023 17:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 14.86 485 2 2
2 12 1126.84 2 15.02 2019 2 2
3 7 2005.16 40 14.46 3113 2 2
4 13 1610.00 19 14.50 2615 2 2
5 13 1046.80 19 14.59 1827 2 2
6 13 609.04 19 14.70 1227 2 2
7 13 163.64 19 14.86 602 2 2
8 8 0.24 170 14.88 335 2 2

Cycle 189 GMT 12/ 3/2023 17:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 14.86 483 2 2
2 12 1117.52 2 15.03 2007 2 2
3 7 2003.36 40 14.47 3106 2 2
4 13 1741.76 19 14.48 2803 2 2
5 13 1044.00 19 14.59 1829 2 2
6 13 608.72 19 14.70 1233 2 2
7 13 178.20 19 14.85 623 2 2
8 8 0.04 170 14.89 335 2 2

Cycle 188 GMT 2/ 3/2023 17:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 29 14.86 493 2 2
2 12 1245.92 2 15.01 2165 2 2
3 7 2003.20 40 14.47 3092 2 2
4 13 1734.28 19 14.48 2787 2 2
5 13 1168.28 19 14.56 1987 2 2
6 13 585.80 19 14.72 1190 2 2
7 13 164.40 19 14.86 599 2 2
8 13 15.76 19 14.92 364 2 2
9 8 0.04 170 14.88 337 2 2

Cycle 187 GMT 20/ 2/2023 16:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 29 14.86 485 2 2
2 12 1129.44 2 15.04 2011 2 2
3 7 2002.56 40 14.49 3068 2 2
4 13 1870.68 19 14.48 2912 2 2
5 13 1147.40 19 14.58 1963 2 2
6 13 576.68 19 14.72 1186 2 2
7 13 154.60 19 14.87 584 2 2
8 13 38.32 19 14.91 399 2 2
9 8 0.04 170 14.88 335 2 3

Cycle 186 GMT 10/ 2/2023 16:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 29 14.87 501 2 2
2 12 1123.72 2 15.03 2024 2 2
3 7 2004.16 40 14.48 3080 2 2
4 13 1734.36 19 14.49 2786 2 2
5 13 1140.76 19 14.57 1953 2 2
6 13 580.64 19 14.72 1188 2 2
7 13 154.68 19 14.87 578 2 2
8 13 41.32 19 14.91 399 2 2
9 8 0.16 170 14.88 336 2 2

Cycle 185 GMT 31/ 1/2023 16:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 14.86 480 2 2
2 12 1123.64 2 15.04 2007 2 2
3 7 2003.28 41 14.48 3089 2 2
4 13 1610.08 19 14.50 2622 2 2
5 13 1186.36 19 14.56 2022 2 2
6 13 491.88 19 14.74 1080 2 2
7 13 111.44 19 14.89 510 2 2
8 8 0.08 170 14.89 333 2 3

Cycle 184 GMT 21/ 1/2023 16: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 14.87 479 2 2
2 12 1230.52 2 14.99 2165 2 2
3 7 2004.32 41 14.47 3104 2 2
4 13 1592.68 19 14.52 2577 2 2
5 13 1160.48 19 14.56 1984 2 2
6 13 586.20 19 14.72 1195 2 2
7 13 155.64 19 14.87 591 2 2
8 8 0.36 170 14.89 332 2 4

Cycle 183 GMT 11/ 1/2023 15:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 14.87 481 2 2
2 12 1242.28 2 15.00 2164 2 2
3 7 2007.28 40 14.48 3098 2 2
4 13 1609.76 19 14.51 2616 2 2
5 13 1179.16 19 14.57 2002 2 2
6 13 595.08 19 14.72 1202 2 2
7 13 161.32 19 14.87 593 2 2
8 8 -0.12 170 14.89 330 2 3

Cycle 182 GMT 1/ 1/2023 15:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.88 463 2 2
2 12 1129.52 2 15.03 2030 2 2
3 7 2001.84 41 14.48 3090 2 2
4 13 1728.80 19 14.50 2758 2 2
5 13 1014.32 19 14.61 1783 2 2
6 13 595.00 19 14.71 1201 2 2
7 13 159.00 19 14.86 598 2 2
8 8 0.04 170 14.89 331 2 3

Cycle 181 GMT 22/12/2022 15:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 29 14.87 496 2 2
2 12 1132.28 2 15.04 2009 2 2
3 7 2006.84 40 14.49 3089 2 2
4 13 1875.56 19 14.47 2962 2 2
5 13 1030.72 19 14.61 1806 2 2
6 13 605.68 19 14.72 1218 2 2
7 13 101.80 19 14.90 501 2 2
8 8 -0.08 170 14.90 328 2 2

Cycle 180 GMT 12/12/2022 15:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 29 14.87 479 2 2
2 12 1123.56 2 15.04 2023 2 2
3 7 2004.36 40 14.48 3084 2 2
4 13 1728.60 19 14.49 2765 2 2
5 13 1023.20 19 14.61 1788 2 2
6 13 610.84 19 14.71 1231 2 2
7 13 184.68 19 14.86 625 2 2
8 8 0.00 170 14.89 333 2 3

Cycle 179 GMT 2/12/2022 15: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 14.87 466 2 2
2 12 1132.32 2 15.04 2013 2 2
3 7 2003.28 40 14.49 3095 2 2
4 13 1739.44 19 14.50 2776 2 2
5 13 1021.00 19 14.61 1779 2 2
6 13 595.92 19 14.72 1219 2 2
7 13 157.72 19 14.87 585 2 2
8 8 0.08 170 14.89 328 2 7

Cycle 178 GMT 22/11/2022 15: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 14.88 473 2 2
2 12 1231.44 2 15.01 2167 2 2
3 7 2004.40 40 14.48 3083 2 2
4 13 1873.12 19 14.47 2961 2 2
5 13 1159.88 19 14.57 1987 2 2
6 13 586.48 19 14.72 1196 2 2
7 13 176.44 19 14.87 617 2 2
8 13 41.28 19 14.92 399 2 2
9 8 -0.04 170 14.89 330 2 2

Cycle 177 GMT 12/11/2022 15: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 14.87 479 2 2
2 12 1124.80 2 15.04 2001 2 2
3 7 2002.12 40 14.48 3091 2 2
4 13 1739.56 19 14.49 2786 2 2
5 13 1160.64 19 14.57 1986 2 2
6 13 455.88 19 14.77 1013 2 2
7 13 99.32 19 14.90 495 2 2
8 8 -0.04 170 14.90 331 2 2

Cycle 176 GMT 2/11/2022 14:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 14.87 471 2 2
2 12 1229.92 2 15.01 2156 2 2
3 7 2004.28 40 14.48 3092 2 2
4 13 1745.88 19 14.49 2793 2 2
5 13 1169.80 19 14.57 2002 2 2
6 13 475.44 19 14.76 1039 2 2
7 13 114.12 19 14.90 521 2 2
8 13 29.96 19 14.92 383 2 2
9 8 0.04 170 14.89 330 2 5

Cycle 175 GMT 23/10/2022 14:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 14.88 466 2 2
2 12 1125.12 2 15.03 2025 2 2
3 7 2003.72 40 14.48 3094 2 2
4 13 1737.60 19 14.49 2785 2 2
5 13 1024.32 19 14.61 1792 2 2
6 13 604.92 19 14.71 1225 2 2
7 13 166.44 19 14.87 606 2 2
8 13 37.72 19 14.91 400 2 2
9 8 0.00 170 14.88 331 2 2

Cycle 174 GMT 13/10/2022 14: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 29 14.87 477 2 2
2 12 1244.08 2 15.01 2212 2 2
3 7 2004.20 40 14.48 3110 2 2
4 13 1739.96 19 14.50 2790 2 2
5 13 1167.64 19 14.57 1994 2 2
6 13 500.28 19 14.75 1078 2 2
7 13 123.76 19 14.89 531 2 2
8 13 30.00 19 14.93 383 2 2
9 8 0.08 170 14.89 327 2 3

Cycle 173 GMT 3/10/2022 13:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 29 14.88 473 2 2
2 12 1232.24 2 15.00 2167 2 2
3 7 2004.40 40 14.49 3071 2 2
4 13 1745.84 19 14.50 2782 2 2
5 13 1041.88 19 14.61 1805 2 2
6 13 488.00 19 14.76 1057 2 2
7 13 116.36 19 14.90 518 2 2
8 13 30.88 19 14.92 380 2 2
9 8 -0.04 170 14.89 325 2 3

Cycle 172 GMT 23/ 9/2022 13:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 14.88 478 2 2
2 12 1123.48 2 15.03 2013 2 2
3 7 2002.48 41 14.48 3067 2 2
4 13 1729.92 19 14.51 2728 2 2
5 13 1026.68 19 14.62 1773 2 2
6 13 485.44 19 14.76 1047 2 2
7 13 103.00 19 14.90 493 2 2
8 13 26.04 19 14.93 377 2 2
9 8 0.08 170 14.89 330 2 3

Cycle 171 GMT 13/ 9/2022 12:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 29 14.88 467 2 2
2 12 1119.92 2 15.04 1977 2 2
3 7 2003.36 40 14.49 3073 2 2
4 13 1604.04 19 14.54 2573 2 2
5 13 1059.32 19 14.61 1840 2 2
6 13 504.24 19 14.75 1075 2 2
7 13 119.36 19 14.90 523 2 2
8 13 29.92 19 14.93 379 2 2
9 8 0.00 170 14.89 328 2 3

Cycle 170 GMT 3/ 9/2022 12:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 14.89 468 2 2
2 12 1238.44 2 15.02 2184 2 2
3 7 2001.40 40 14.49 3073 2 2
4 13 1606.88 19 14.53 2566 2 2
5 13 1049.24 19 14.61 1828 2 2
6 13 493.16 19 14.76 1071 2 2
7 13 113.36 19 14.90 508 2 2
8 13 26.44 19 14.93 372 2 2
9 8 0.08 170 14.90 325 2 3

Cycle 169 GMT 24/ 8/2022 11:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 29 14.89 461 2 2
2 12 1125.92 2 15.05 2012 2 2
3 7 2004.20 41 14.49 3075 2 2
4 13 1736.20 19 14.51 2743 2 2
5 13 1163.52 19 14.59 1941 2 2
6 13 458.24 19 14.78 1011 2 2
7 13 104.32 19 14.91 494 2 2
8 13 25.12 19 14.93 374 2 2
9 8 0.08 170 14.90 325 2 3

Cycle 168 GMT 14/ 8/2022 11:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 29 14.87 484 2 2
2 12 1141.32 2 15.06 2016 2 2
3 7 2002.68 40 14.49 3074 2 2
4 13 1727.40 19 14.50 2774 2 2
5 13 1292.44 19 14.55 2154 2 2
6 13 580.08 19 14.74 1183 2 2
7 13 158.20 19 14.89 583 2 2
8 13 18.80 19 14.94 361 2 2
9 8 0.16 170 14.90 326 2 4

Cycle 167 GMT 4/ 8/2022 11:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 29 14.89 468 2 2
2 12 1125.92 2 15.05 2021 2 2
3 7 2004.92 40 14.49 3076 2 2
4 13 1729.68 19 14.50 2777 2 2
5 13 1153.32 19 14.58 1971 2 2
6 13 448.08 19 14.78 1001 2 2
7 13 169.28 19 14.88 607 2 2
8 13 35.92 19 14.92 397 2 2
9 8 0.00 170 14.89 333 2 3

Cycle 166 GMT 25/ 7/2022 11: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 14.89 471 2 2
2 12 1130.52 2 15.05 1986 2 2
3 7 2001.92 40 14.49 3081 2 2
4 13 1483.80 19 14.55 2439 2 2
5 13 1063.08 19 14.60 1843 2 2
6 13 492.56 19 14.77 1053 2 2
7 13 117.04 19 14.90 508 2 2
8 8 0.16 170 14.91 324 2 6

Cycle 165 GMT 15/ 7/2022 10:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 14.90 456 2 2
2 12 1250.92 2 15.00 2195 2 2
3 7 2004.24 40 14.50 3076 2 2
4 13 1597.72 19 14.52 2600 2 2
5 13 1046.68 19 14.61 1824 2 2
6 13 489.92 19 14.77 1058 2 2
7 13 113.72 19 14.91 505 2 2
8 13 15.08 19 14.94 346 2 2
9 8 0.08 170 14.90 322 2 3

Cycle 164 GMT 5/ 7/2022 10:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 29 14.89 464 2 2
2 12 1122.92 2 15.05 2018 2 2
3 7 2004.40 40 14.50 3070 2 2
4 13 1735.84 19 14.51 2756 2 2
5 13 1167.84 19 14.59 1992 2 2
6 13 594.24 19 14.73 1204 2 2
7 13 169.60 19 14.89 593 2 2
8 8 0.04 170 14.92 316 2 3

Cycle 163 GMT 25/ 6/2022 10:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 29 14.88 495 2 2
2 12 1127.44 2 15.06 2004 2 2
3 7 2002.92 40 14.50 3073 2 2
4 13 1739.84 19 14.52 2740 2 2
5 13 1045.08 19 14.62 1825 2 2
6 13 623.80 19 14.72 1252 2 2
7 13 110.32 19 14.91 505 2 2
8 8 -0.04 170 14.91 324 2 3

Cycle 162 GMT 15/ 6/2022 10:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 28 14.89 475 2 2
2 12 1232.52 2 15.01 2157 2 2
3 7 2001.64 40 14.49 3092 2 2
4 13 1724.72 19 14.51 2760 2 2
5 13 1012.76 19 14.63 1781 2 2
6 13 582.60 19 14.74 1189 2 2
7 13 159.88 19 14.89 584 2 2
8 13 14.72 19 14.94 341 2 2
9 8 0.08 170 14.90 326 2 3

Cycle 161 GMT 5/ 6/2022 10:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 28 14.89 471 2 2
2 12 1125.72 2 15.05 2013 2 2
3 7 2005.88 40 14.50 3100 2 2
4 13 1600.12 19 14.53 2608 2 2
5 13 1199.36 19 14.57 2040 2 2
6 13 604.12 19 14.73 1221 2 2
7 13 171.00 19 14.88 606 2 2
8 8 0.12 170 14.91 329 2 3

Cycle 160 GMT 26/ 5/2022 10: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 28 14.88 478 2 2
2 12 1141.80 2 15.04 2041 2 2
3 7 2004.92 40 14.49 3105 2 2
4 13 1734.92 19 14.51 2780 2 2
5 13 1039.88 19 14.63 1811 2 2
6 13 609.64 19 14.73 1229 2 2
7 13 186.88 19 14.88 626 2 2
8 8 -0.04 170 14.91 330 2 2

Cycle 159 GMT 16/ 5/2022 9:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 14.88 475 2 2
2 12 1135.76 2 15.05 2038 2 2
3 7 2003.92 41 14.49 3100 2 2
4 13 1598.84 19 14.54 2591 2 2
5 13 1191.08 19 14.58 2018 2 2
6 13 498.96 19 14.77 1068 2 2
7 13 121.64 19 14.91 531 2 2
8 8 0.08 170 14.91 340 2 3

Cycle 158 GMT 6/ 5/2022 9:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 28 14.89 471 2 2
2 12 1129.56 2 15.05 2014 2 2
3 7 2004.96 41 14.49 3108 2 2
4 13 1739.56 19 14.51 2780 2 2
5 13 1174.48 19 14.59 1998 2 2
6 13 591.24 19 14.75 1197 2 2
7 13 158.76 19 14.89 590 2 2
8 8 0.08 170 14.91 333 2 2

Cycle 157 GMT 26/ 4/2022 9:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 28 14.88 487 2 2
2 12 1131.00 2 15.06 2018 2 2
3 7 2003.72 41 14.49 3113 2 2
4 13 1478.72 19 14.56 2426 2 2
5 13 1069.64 19 14.61 1853 2 2
6 13 643.60 19 14.72 1269 2 2
7 13 117.92 19 14.91 521 2 2
8 8 0.20 170 14.91 332 2 2

Cycle 156 GMT 16/ 4/2022 8:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 28 14.89 479 2 2
2 12 1237.92 2 15.02 2135 2 2
3 7 2005.04 40 14.50 3086 2 2
4 13 1733.92 19 14.52 2776 2 2
5 13 1163.00 19 14.59 1984 2 2
6 13 595.36 19 14.75 1200 2 2
7 13 165.56 19 14.89 595 2 2
8 8 0.08 170 14.92 333 2 4

Cycle 155 GMT 6/ 4/2022 8:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 28 14.89 490 2 2
2 12 1137.72 2 15.07 2008 2 2
3 7 2002.92 40 14.49 3117 2 2
4 13 1607.80 19 14.53 2620 2 2
5 13 1057.60 19 14.62 1839 2 2
6 13 634.60 19 14.72 1265 2 2
7 13 114.64 19 14.92 506 2 2
8 8 0.16 170 14.92 328 2 3

Cycle 154 GMT 27/ 3/2022 8:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 14.88 477 2 2
2 3 1020.96 1 15.00 1890 2 2
3 12 1124.56 2 15.06 2014 2 2
4 7 2002.56 40 14.51 3065 2 2
5 13 1600.56 19 14.55 2578 2 2
6 13 1330.24 19 14.55 2223 2 2
7 13 592.76 19 14.74 1214 2 2
8 13 161.24 19 14.90 586 2 2
9 8 0.04 170 14.92 332 2 3
10 14 0.04 30 14.89 336 2 3

Cycle 153 GMT 17/ 3/2022 7:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 28 14.88 494 2 2
2 12 1231.16 2 15.01 2167 2 2
3 7 2003.00 40 14.50 3088 2 2
4 13 1604.68 19 14.54 2600 2 2
5 13 1030.92 19 14.63 1807 2 2
6 13 600.00 19 14.74 1219 2 2
7 13 160.64 19 14.89 592 2 2
8 8 0.00 170 14.91 338 2 3

Cycle 152 GMT 7/ 3/2022 7:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 28 14.88 484 2 2
2 12 1130.44 2 15.06 2014 2 2
3 7 2004.28 40 14.51 3071 2 2
4 13 1739.44 19 14.52 2781 2 2
5 13 1164.88 19 14.60 2001 2 2
6 13 728.56 19 14.70 1399 2 2
7 13 135.04 19 14.91 552 2 2
8 8 0.20 170 14.92 336 2 2

Cycle 151 GMT 25/ 2/2022 7:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 28 14.90 488 2 2
2 12 1128.56 2 15.08 2003 2 2
3 7 2003.44 40 14.51 3072 2 2
4 13 1733.84 19 14.52 2778 2 2
5 13 1159.20 19 14.60 1969 2 2
6 13 598.88 19 14.75 1208 2 2
7 13 165.24 19 14.90 600 2 2
8 8 -0.08 170 14.92 339 2 4

Cycle 150 GMT 15/ 2/2022 7:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 28 14.89 491 2 2
2 12 1142.44 2 15.06 2041 2 2
3 7 2001.68 40 14.51 3094 2 2
4 13 1728.24 19 14.53 2779 2 2
5 13 1164.36 19 14.60 1988 2 2
6 13 484.28 19 14.79 1053 2 2
7 13 108.92 19 14.93 510 2 2
8 8 0.12 170 14.92 338 2 3

Cycle 149 GMT 5/ 2/2022 7: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 14.90 481 2 2
2 12 1119.04 2 15.07 2005 2 2
3 7 2005.60 40 14.51 3076 2 2
4 13 1735.84 19 14.53 2754 2 2
5 13 1161.52 19 14.60 1989 2 2
6 13 590.24 19 14.75 1210 2 2
7 13 157.16 19 14.91 585 2 2
8 8 0.24 170 14.92 336 2 2

Cycle 148 GMT 26/ 1/2022 7: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 28 14.90 473 2 2
2 12 1132.44 2 15.06 2018 2 2
3 7 2002.92 40 14.50 3111 2 2
4 13 1606.28 19 14.54 2608 2 2
5 13 1062.96 19 14.63 1850 2 2
6 13 508.52 19 14.78 1090 2 2
7 13 126.36 19 14.92 536 2 2
8 8 0.00 170 14.93 333 2 2

Cycle 147 GMT 16/ 1/2022 6:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 14.89 486 2 2
2 12 1127.68 2 15.05 2024 2 2
3 7 2004.96 40 14.51 3071 2 2
4 13 1597.32 19 14.55 2582 2 2
5 13 1169.12 19 14.60 2002 2 2
6 13 590.64 19 14.75 1206 2 2
7 13 93.60 19 14.94 483 2 2
8 8 0.08 170 14.93 333 2 2

Cycle 146 GMT 6/ 1/2022 6:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 28 14.90 506 2 2
2 12 1133.00 2 15.06 2000 2 2
3 7 2002.68 40 14.51 3068 2 2
4 13 1734.28 19 14.53 2738 2 2
5 13 1161.24 19 14.62 1946 2 2
6 13 581.24 19 14.76 1192 2 2
7 13 153.36 19 14.91 582 2 2
8 8 0.04 170 14.92 339 2 3

Cycle 145 GMT 27/12/2021 5:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 28 14.90 480 2 2
2 12 1125.92 2 15.07 2006 2 2
3 7 2005.08 40 14.51 3068 2 2
4 13 1595.88 19 14.56 2546 2 2
5 13 1042.40 19 14.63 1812 2 2
6 13 476.48 19 14.80 1036 2 2
7 13 110.28 19 14.93 505 2 2
8 8 0.04 170 14.93 334 2 3

Cycle 144 GMT 17/12/2021 5:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 14.90 482 2 2
2 3 1018.64 1 15.03 1881 2 2
3 12 1233.96 2 15.03 2137 2 2
4 7 2003.44 40 14.52 3066 2 2
5 13 1738.64 19 14.52 2773 2 2
6 13 1161.16 19 14.61 1979 2 2
7 13 586.84 19 14.76 1203 2 2
8 13 161.64 19 14.91 592 2 2
9 8 0.12 170 14.93 331 2 2

Cycle 143 GMT 7/12/2021 5:14: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 28 14.92 468 2 2
2 12 1130.56 2 15.08 2007 2 2
3 7 2002.56 40 14.51 3069 2 2
4 13 1732.40 19 14.54 2733 2 2
5 13 1157.48 19 14.61 1974 2 2
6 13 576.56 19 14.77 1187 2 2
7 13 147.88 19 14.92 574 2 2
8 8 0.16 170 14.93 331 2 3

Cycle 142 GMT 27/11/2021 5: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 28 14.92 472 2 2
2 12 1131.44 2 15.06 2032 2 2
3 7 2004.84 40 14.51 3070 2 2
4 13 1604.84 19 14.55 2605 2 2
5 13 1070.04 19 14.63 1863 2 2
6 13 644.64 19 14.74 1280 2 2
7 13 115.40 19 14.93 513 2 2
8 8 0.08 170 14.94 327 2 3

Cycle 141 GMT 17/11/2021 4:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 28 14.92 468 2 2
2 12 1240.28 2 15.02 2189 2 2
3 7 2001.28 40 14.50 3115 2 2
4 13 1603.56 19 14.54 2603 2 2
5 13 1062.84 19 14.63 1844 2 2
6 13 628.60 19 14.75 1262 2 2
7 13 114.80 19 14.93 514 2 2
8 8 0.00 170 14.94 327 2 2

Cycle 140 GMT 7/11/2021 3:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 14.91 463 2 2
2 12 1141.12 2 15.06 2021 2 2
3 7 2004.48 40 14.52 3074 2 2
4 13 1605.72 19 14.55 2607 2 2
5 13 1176.72 19 14.60 2002 2 2
6 13 478.40 19 14.80 1045 2 2
7 13 113.52 19 14.93 514 2 2
8 8 0.16 170 14.94 326 2 2

Cycle 139 GMT 28/10/2021 3:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 14.91 461 2 2
2 12 1132.20 2 15.06 2026 2 2
3 7 2006.64 41 14.51 3098 2 2
4 13 1604.60 19 14.54 2603 2 2
5 13 1041.44 19 14.64 1830 2 2
6 13 622.72 19 14.75 1251 2 2
7 13 110.44 19 14.94 507 2 2
8 13 12.68 19 14.97 349 2 2
9 8 -0.04 170 14.93 328 2 3

Cycle 138 GMT 18/10/2021 3:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 14.91 475 2 2
2 12 1139.84 2 15.07 2020 2 2
3 7 2003.04 40 14.52 3086 2 2
4 13 1733.56 19 14.53 2772 2 2
5 13 1033.24 19 14.65 1808 2 2
6 13 613.28 19 14.76 1241 2 2
7 13 179.20 19 14.91 620 2 2
8 13 42.80 19 14.96 399 2 2
9 8 0.04 170 14.93 328 2 3

Cycle 137 GMT 8/10/2021 2:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 28 14.92 464 2 2
2 12 1136.04 2 15.06 2027 2 2
3 7 2002.96 40 14.50 3096 2 2
4 13 1722.88 19 14.53 2759 2 2
5 13 1146.84 19 14.62 1958 2 2
6 13 584.88 19 14.77 1193 2 2
7 13 163.00 19 14.92 591 2 2
8 13 36.60 19 14.96 395 2 2
9 8 -0.08 170 14.93 326 2 2

Cycle 136 GMT 28/ 9/2021 2:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 14.92 463 2 2
2 12 1128.28 2 15.05 2027 2 2
3 7 2004.28 40 14.52 3068 2 2
4 13 1750.12 19 14.53 2772 2 2
5 13 1164.52 19 14.62 1982 2 2
6 13 597.88 19 14.77 1212 2 2
7 13 175.04 19 14.91 613 2 2
8 13 21.56 19 14.97 369 2 2
9 8 0.12 170 14.94 328 2 3

Cycle 135 GMT 18/ 9/2021 1:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 28 14.92 471 2 2
2 12 1135.64 2 15.07 2047 2 2
3 7 2004.92 40 14.52 3089 2 2
4 13 1588.68 19 14.56 2597 2 2
5 13 1039.96 19 14.66 1809 2 2
6 13 490.72 19 14.81 1058 2 2
7 13 119.28 19 14.94 515 2 2
8 13 30.00 19 14.97 380 2 2
9 8 0.00 170 14.94 326 2 3

Cycle 134 GMT 8/ 9/2021 1:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 28 14.92 464 2 2
2 12 1125.56 2 15.08 2020 2 2
3 7 2004.60 40 14.52 3074 2 2
4 13 1724.52 19 14.53 2777 2 2
5 13 1035.64 19 14.66 1808 2 2
6 13 482.52 19 14.82 1045 2 2
7 13 111.44 19 14.95 510 2 2
8 13 14.00 19 14.98 347 2 2
9 8 -0.08 170 14.94 327 2 2

Cycle 133 GMT 29/ 8/2021 1: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.92 473 2 2
2 12 1120.24 2 15.07 2019 2 2
3 7 2001.28 40 14.52 3076 2 2
4 13 1736.88 19 14.54 2753 2 2
5 13 1160.88 19 14.62 1968 2 2
6 13 584.56 19 14.77 1190 2 2
7 13 157.48 19 14.93 586 2 2
8 13 20.88 19 14.98 367 2 2
9 8 -0.08 170 14.94 331 2 4

Cycle 132 GMT 19/ 8/2021 0:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 28 14.92 479 2 2
2 12 1135.36 2 15.06 2042 2 2
3 7 2004.40 40 14.53 3086 2 2
4 13 1596.92 19 14.56 2592 2 2
5 13 1056.08 19 14.65 1833 2 2
6 13 496.28 19 14.81 1068 2 2
7 13 119.60 19 14.95 518 2 2
8 13 28.56 19 14.97 376 2 2
9 8 0.08 170 14.94 330 2 2

Cycle 131 GMT 9/ 8/2021 0:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 28 14.91 479 2 2
2 12 1124.24 2 15.08 2018 2 2
3 7 2002.24 41 14.52 3061 2 2
4 13 1599.12 19 14.56 2579 2 2
5 13 1164.40 19 14.62 1982 2 2
6 13 584.96 19 14.77 1191 2 2
7 13 157.04 19 14.93 582 2 2
8 13 18.64 19 14.98 363 2 2
9 8 0.04 170 14.94 332 2 3

Cycle 130 GMT 29/ 7/2021 23:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 28 14.92 480 2 2
2 12 1125.88 2 15.07 2025 2 2
3 7 2003.72 41 14.53 3068 2 2
4 13 1588.44 19 14.56 2584 2 2
5 13 1017.56 19 14.67 1777 2 2
6 13 589.80 19 14.78 1203 2 2
7 13 150.72 19 14.93 573 2 2
8 13 18.44 19 14.98 360 2 2
9 8 0.00 170 14.94 329 2 2

Cycle 129 GMT 19/ 7/2021 23:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 28 14.92 483 2 2
2 12 1128.16 2 15.08 2024 2 2
3 7 2002.80 40 14.52 3082 2 2
4 13 1601.44 19 14.56 2598 2 2
5 13 1045.44 19 14.66 1827 2 2
6 13 481.88 19 14.82 1042 2 2
7 13 108.68 19 14.95 504 2 2
8 13 25.88 19 14.98 372 2 2
9 8 0.04 170 14.94 328 2 3

Cycle 128 GMT 9/ 7/2021 23: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 28 14.93 476 2 2
2 12 1131.20 2 15.08 2015 2 2
3 7 2003.24 40 14.53 3068 2 2
4 13 1608.00 19 14.57 2564 2 2
5 13 1180.84 19 14.63 1983 2 2
6 13 476.12 19 14.82 1040 2 2
7 13 114.48 19 14.95 513 2 2
8 13 25.76 19 14.98 370 2 2
9 8 0.04 170 14.95 328 2 2

Cycle 127 GMT 29/ 6/2021 23: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 14.92 479 2 2
2 12 1125.60 2 15.07 2020 2 2
3 7 2005.84 41 14.53 3070 2 2
4 13 1601.16 19 14.57 2590 2 2
5 13 1045.88 19 14.65 1826 2 2
6 13 614.00 19 14.77 1235 2 2
7 13 101.00 19 14.96 491 2 2
8 8 0.12 170 14.95 329 2 3

Cycle 126 GMT 19/ 6/2021 22:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 14.93 480 2 2
2 3 1018.12 1 15.05 1871 2 2
3 12 1135.48 2 15.07 2031 2 2
4 7 2002.92 40 14.53 3082 2 2
5 13 1725.00 19 14.54 2771 2 2
6 13 1150.72 19 14.63 1968 2 2
7 13 588.60 19 14.79 1197 2 2
8 13 157.80 19 14.93 588 2 2
9 13 15.32 19 14.99 360 2 2
10 8 0.16 170 14.94 334 2 2

Cycle 125 GMT 9/ 6/2021 22:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 14.94 478 2 2
2 12 1134.84 2 15.09 2019 2 2
3 7 2002.88 40 14.53 3071 2 2
4 13 1725.44 19 14.56 2735 2 2
5 13 1140.28 19 14.65 1945 2 2
6 13 693.28 19 14.74 1357 2 2
7 13 136.96 19 14.95 551 2 2
8 8 0.12 170 14.96 335 2 3

Cycle 124 GMT 30/ 5/2021 22:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 14.93 484 2 2
2 12 1128.36 2 15.09 1996 2 2
3 7 2001.52 40 14.53 3072 2 2
4 13 1724.76 19 14.54 2754 2 2
5 13 1152.00 19 14.64 1967 2 2
6 13 459.48 19 14.84 1015 2 2
7 13 107.52 19 14.97 493 2 2
8 8 0.04 170 14.96 331 2 3

Cycle 123 GMT 20/ 5/2021 22:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 28 14.93 484 2 2
2 12 1138.96 2 15.09 2029 2 2
3 7 2001.48 40 14.53 3073 2 2
4 13 1732.08 19 14.55 2750 2 2
5 13 1023.80 19 14.68 1788 2 2
6 13 605.88 19 14.78 1228 2 2
7 13 169.68 19 14.94 597 2 2
8 8 0.08 170 14.95 335 2 3

Cycle 122 GMT 10/ 5/2021 21:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 28 14.92 488 2 2
2 12 1114.92 2 15.08 2009 2 2
3 7 2002.48 40 14.53 3072 2 2
4 13 1742.72 19 14.55 2750 2 2
5 13 1170.16 19 14.64 1973 2 2
6 13 590.36 19 14.79 1201 2 2
7 13 155.48 19 14.94 584 2 2
8 8 0.12 170 14.96 335 2 3

Cycle 121 GMT 30/ 4/2021 21:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 28 14.92 489 2 2
2 12 1137.48 2 15.07 2032 2 2
3 7 2005.64 40 14.53 3083 2 2
4 13 1878.76 19 14.52 2942 2 2
5 13 1018.24 19 14.69 1786 2 2
6 13 591.44 19 14.79 1200 2 2
7 13 162.00 19 14.94 594 2 2
8 8 0.04 170 14.96 335 2 3

Cycle 120 GMT 20/ 4/2021 21:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 28 14.93 483 2 2
2 12 1118.24 2 15.08 2009 2 2
3 7 2004.36 40 14.54 3072 2 2
4 13 1741.28 19 14.54 2791 2 2
5 13 1021.96 19 14.68 1793 2 2
6 13 602.16 19 14.79 1222 2 2
7 13 177.16 19 14.93 618 2 2
8 8 0.08 170 14.96 336 2 3

Cycle 119 GMT 10/ 4/2021 21:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 28 14.93 482 2 2
2 12 1132.72 2 15.09 2019 2 2
3 7 2002.76 40 14.53 3098 2 2
4 13 1609.84 19 14.57 2618 2 2
5 13 1065.60 19 14.66 1863 2 2
6 13 493.92 19 14.83 1062 2 2
7 13 112.12 19 14.96 512 2 2
8 8 0.04 170 14.96 335 2 3

Cycle 118 GMT 31/ 3/2021 20:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 28 14.93 484 2 2
2 12 1133.48 2 15.09 2016 2 2
3 7 2002.20 40 14.54 3066 2 2
4 13 1472.12 19 14.61 2382 2 2
5 13 1066.72 19 14.66 1854 2 2
6 13 484.80 19 14.83 1058 2 2
7 13 114.92 19 14.96 519 2 2
8 8 0.08 170 14.96 336 2 4

Cycle 117 GMT 21/ 3/2021 20:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 14.94 481 2 2
2 12 1132.44 2 15.09 2012 2 2
3 7 2004.76 40 14.53 3100 2 2
4 13 1600.64 19 14.57 2598 2 2
5 13 1175.60 19 14.63 2000 2 2
6 13 597.36 19 14.79 1222 2 2
7 13 105.32 19 14.97 504 2 2
8 8 0.16 170 14.96 341 2 2

Cycle 116 GMT 11/ 3/2021 19:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 14.93 502 2 2
2 12 1118.96 2 15.08 2022 2 2
3 7 2010.52 41 14.54 3080 2 2
4 13 1883.84 19 14.53 2936 2 2
5 13 1039.16 19 14.69 1801 2 2
6 13 481.20 19 14.84 1048 2 2
7 13 120.12 19 14.97 521 2 2
8 8 0.08 170 14.97 334 2 2

Cycle 115 GMT 1/ 3/2021 19:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 28 14.93 488 2 2
2 12 1233.80 2 15.05 2165 2 2
3 7 2002.12 40 14.53 3066 2 2
4 13 1594.32 19 14.58 2559 2 2
5 13 1173.56 19 14.64 1995 2 2
6 13 581.04 19 14.80 1188 2 2
7 13 143.76 19 14.95 571 2 2
8 13 15.88 19 15.00 365 2 2
9 8 0.04 170 14.96 336 2 3

Cycle 114 GMT 19/ 2/2021 19: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 28 14.94 480 2 2
2 3 1021.84 1 15.09 1888 2 2
3 12 1117.48 2 15.10 1989 2 2
4 7 2001.56 40 14.54 3070 2 2
5 13 1583.24 19 14.59 2552 2 2
6 13 1035.16 19 14.68 1822 2 2
7 13 480.24 19 14.84 1053 2 2
8 13 106.52 19 14.97 503 2 2
9 8 0.28 170 14.97 339 2 2

Cycle 113 GMT 9/ 2/2021 18:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 14.94 478 2 2
2 12 1147.80 2 15.09 2019 2 2
3 7 2003.16 40 14.54 3081 2 2
4 13 1734.00 19 14.55 2793 2 2
5 13 915.12 19 14.72 1643 2 2
6 13 502.12 19 14.83 1074 2 2
7 13 127.24 19 14.97 537 2 2
8 8 0.04 170 14.97 334 2 3

Cycle 112 GMT 30/ 1/2021 18:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 28 14.93 484 2 2
2 12 1129.88 2 15.11 2002 2 2
3 7 2002.00 40 14.55 3067 2 2
4 13 1599.20 19 14.59 2562 2 2
5 13 1049.64 19 14.68 1837 2 2
6 13 623.60 19 14.79 1249 2 2
7 13 111.52 19 14.97 509 2 2
8 8 0.00 170 14.97 329 2 3

Cycle 111 GMT 20/ 1/2021 17:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 14.94 472 2 2
2 12 1129.60 2 15.08 2033 2 2
3 7 2004.68 41 14.53 3069 2 2
4 13 1873.20 19 14.53 2968 2 2
5 13 1133.36 19 14.66 1938 2 2
6 13 563.28 19 14.81 1168 2 2
7 13 142.12 19 14.96 564 2 2
8 13 17.72 19 15.01 358 2 2
9 8 0.12 170 14.96 333 2 4

Cycle 110 GMT 10/ 1/2021 17:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 28 14.95 480 2 2
2 12 1126.36 2 15.10 2021 2 2
3 7 2002.88 40 14.53 3072 2 2
4 13 1600.88 19 14.58 2572 2 2
5 13 907.80 19 14.72 1640 2 2
6 13 492.80 19 14.84 1064 2 2
7 13 108.76 19 14.97 509 2 2
8 13 23.12 19 15.00 370 2 2
9 8 -0.08 170 14.96 331 2 3

Cycle 109 GMT 31/12/2020 16:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 28 14.95 480 2 2
2 12 1123.00 2 15.08 2020 2 2
3 7 2004.00 40 14.54 3082 2 2
4 13 1732.56 19 14.56 2773 2 2
5 13 1023.64 19 14.69 1790 2 2
6 13 476.76 19 14.85 1039 2 2
7 13 116.72 19 14.98 516 2 2
8 8 0.12 170 14.98 332 2 2

Cycle 108 GMT 21/12/2020 16:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 14.95 465 2 2
2 12 1121.20 2 15.10 1979 2 2
3 7 2004.72 40 14.54 3089 2 2
4 13 1598.36 19 14.58 2611 2 2
5 13 1035.64 19 14.69 1813 2 2
6 13 474.28 19 14.85 1039 2 2
7 13 113.44 19 14.98 514 2 2
8 8 0.08 170 14.98 329 2 4

Cycle 107 GMT 11/12/2020 15:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 28 14.95 476 2 2
2 12 1125.64 2 15.09 2021 2 2
3 7 2004.16 40 14.54 3077 2 2
4 13 1611.24 19 14.59 2582 2 2
5 13 1047.08 19 14.70 1793 2 2
6 13 491.32 19 14.84 1057 2 2
7 13 112.64 19 14.98 517 2 2
8 8 0.00 170 14.98 328 2 5

Cycle 106 GMT 1/12/2020 15:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 28 14.95 484 2 2
2 12 1123.40 2 15.12 1996 2 2
3 7 2003.84 40 14.54 3081 2 2
4 13 1601.40 19 14.58 2606 2 2
5 13 1039.96 19 14.69 1821 2 2
6 13 477.48 19 14.85 1044 2 2
7 13 109.16 19 14.98 511 2 2
8 13 31.92 19 15.00 388 2 2
9 8 -0.08 170 14.97 329 2 3

Cycle 105 GMT 21/11/2020 14:30: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 28 14.95 489 2 2
2 12 1123.56 2 15.08 2014 2 2
3 7 2002.80 40 14.55 3067 2 2
4 13 1613.08 19 14.59 2584 2 2
5 13 1064.72 19 14.69 1808 2 2
6 13 505.36 19 14.84 1074 2 2
7 13 119.00 19 14.98 526 2 2
8 13 28.56 19 15.00 382 2 2
9 8 -0.04 170 14.97 328 2 4

Cycle 104 GMT 11/11/2020 13:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 28 14.96 489 2 2
2 12 1141.28 2 15.09 2024 2 2
3 7 2005.00 40 14.55 3074 2 2
4 13 1604.52 19 14.58 2605 2 2
5 13 1028.72 19 14.69 1804 2 2
6 13 475.28 19 14.85 1044 2 2
7 13 97.44 19 14.99 493 2 2
8 8 0.16 170 14.98 329 2 2

Cycle 103 GMT 1/11/2020 13:23:46

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 28 14.94 479 2 2
2 12 1241.92 2 15.06 2184 2 2
3 7 2003.16 41 14.54 3077 2 2
4 13 1600.00 19 14.58 2604 2 2
5 13 1046.80 19 14.69 1835 2 2
6 13 473.60 19 14.85 1043 2 2
7 13 106.28 19 14.98 510 2 2
8 13 25.36 19 15.01 382 2 2
9 8 -0.08 170 14.97 330 2 2

Cycle 102 GMT 22/10/2020 13: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 28 14.94 484 2 2
2 12 1127.12 2 15.10 2040 2 2
3 7 2002.80 40 14.54 3068 2 2
4 13 1582.80 19 14.59 2563 2 2
5 13 1031.84 19 14.70 1799 2 2
6 13 587.80 19 14.81 1203 2 2
7 13 141.28 19 14.96 563 2 2
8 13 32.60 19 15.00 389 2 2
9 8 0.00 170 14.97 333 2 2

Cycle 101 GMT 12/10/2020 12:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 14.95 479 2 2
2 3 1018.28 1 15.10 1884 2 2
3 12 1113.44 2 15.11 1996 2 2
4 7 2003.00 40 14.55 3084 2 2
5 13 1473.04 19 14.62 2394 2 2
6 13 1080.92 19 14.68 1856 2 2
7 13 519.08 19 14.84 1108 2 2
8 13 125.00 19 14.97 538 2 2
9 13 29.52 19 15.01 384 2 2
10 8 0.12 170 14.97 330 2 3

Cycle 100 GMT 2/10/2020 12: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 14.95 476 2 2
2 12 1143.12 2 15.11 2020 2 2
3 7 2011.16 40 14.55 3080 2 2
4 13 1879.84 19 14.54 2949 2 2
5 13 1146.56 19 14.67 1956 2 2
6 13 578.88 19 14.82 1189 2 2
7 13 153.76 19 14.96 586 2 2
8 13 20.48 19 15.01 372 2 2
9 8 0.04 170 14.98 331 2 4

Cycle 99 GMT 22/ 9/2020 11:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.95 474 2 2
2 12 1138.04 2 15.09 2043 2 2
3 7 2003.52 40 14.55 3076 2 2
4 13 1604.88 19 14.59 2595 2 2
5 13 1173.48 19 14.66 1998 2 2
6 13 593.56 19 14.81 1206 2 2
7 13 91.68 19 14.99 485 2 2
8 13 25.00 19 15.01 376 2 2
9 8 0.08 170 14.98 331 2 2

Cycle 98 GMT 12/ 9/2020 11: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 14.95 478 2 2
2 12 1129.16 2 15.09 2025 2 2
3 7 2003.64 40 14.56 3069 2 2
4 13 1733.68 19 14.57 2746 2 2
5 13 1010.04 19 14.72 1746 2 2
6 13 584.52 19 14.82 1163 2 2
7 13 83.40 19 15.00 458 2 2
8 13 22.88 19 15.02 377 2 2
9 8 0.00 170 14.98 331 2 7

Cycle 97 GMT 2/ 9/2020 10:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 28 14.95 466 2 2
2 12 1128.84 2 15.11 2009 2 2
3 7 2001.72 41 14.55 3058 2 2
4 13 1590.08 19 14.59 2571 2 2
5 13 1173.60 19 14.66 1995 2 2
6 13 463.64 19 14.87 1010 2 2
7 13 98.56 19 14.99 489 2 2
8 13 24.44 19 15.01 378 2 2
9 8 0.04 170 14.98 330 2 2

Cycle 96 GMT 23/ 8/2020 10:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 14.95 484 2 2
2 12 1138.64 2 15.09 2023 2 2
3 7 2003.20 40 14.55 3067 2 2
4 13 1602.24 19 14.60 2584 2 2
5 13 1046.60 19 14.70 1821 2 2
6 13 483.12 19 14.86 1048 2 2
7 13 107.84 19 14.99 507 2 2
8 13 25.84 19 15.01 371 2 2
9 8 -0.04 170 14.98 328 2 4

Cycle 95 GMT 13/ 8/2020 10:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 28 14.96 478 2 2
2 3 1018.20 1 15.07 1895 2 2
3 12 1129.52 2 15.09 1990 2 2
4 7 2001.80 40 14.55 3070 2 2
5 13 1599.56 19 14.61 2560 2 2
6 13 1048.80 19 14.70 1790 2 2
7 13 493.36 19 14.86 1034 2 2
8 13 110.76 19 14.99 512 2 2
9 13 25.32 19 15.01 379 2 2
10 8 0.04 170 14.98 328 2 4

Cycle 94 GMT 3/ 8/2020 9:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 28 14.95 465 2 2
2 12 1128.40 2 15.09 2011 2 2
3 7 2005.44 40 14.56 3069 2 2
4 13 1601.28 19 14.60 2581 2 2
5 13 1034.60 19 14.71 1770 2 2
6 13 474.80 19 14.88 998 2 2
7 13 103.56 19 15.00 495 2 2
8 13 22.96 19 15.02 371 2 2
9 8 0.12 170 14.98 328 2 3

Cycle 93 GMT 24/ 7/2020 9:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.96 465 2 2
2 12 1233.44 2 15.07 2175 2 2
3 7 2004.44 40 14.55 3072 2 2
4 13 1606.48 19 14.60 2588 2 2
5 13 1060.44 19 14.69 1840 2 2
6 13 627.84 19 14.81 1244 2 2
7 13 102.16 19 15.00 490 2 2
8 13 25.12 19 15.02 367 2 2
9 8 -0.08 170 14.98 324 2 4

Cycle 92 GMT 14/ 7/2020 8:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 14.96 470 2 2
2 12 1122.52 2 15.10 2014 2 2
3 7 2004.64 40 14.55 3069 2 2
4 13 1873.28 19 14.54 2941 2 2
5 13 994.92 19 14.72 1753 2 2
6 13 458.52 19 14.87 1008 2 2
7 13 101.52 19 15.00 495 2 2
8 13 23.60 19 15.02 368 2 2
9 8 0.08 170 14.99 325 2 5

Cycle 91 GMT 4/ 7/2020 8:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 14.95 472 2 2
2 12 1141.60 2 15.09 2046 2 2
3 7 2001.16 40 14.56 3076 2 2
4 13 1599.16 19 14.60 2595 2 2
5 13 1048.00 19 14.70 1821 2 2
6 13 485.08 19 14.86 1054 2 2
7 13 109.52 19 14.99 513 2 2
8 8 0.08 170 14.99 333 2 3

Cycle 90 GMT 24/ 6/2020 8:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 28 14.96 477 2 2
2 12 1134.00 2 15.09 2022 2 2
3 7 2002.16 40 14.55 3091 2 2
4 13 1595.92 19 14.60 2595 2 2
5 13 1048.92 19 14.70 1828 2 2
6 13 495.80 19 14.86 1066 2 2
7 13 112.76 19 14.99 522 2 2
8 13 13.76 19 15.02 363 2 2
9 8 0.00 170 14.98 336 2 2

Cycle 89 GMT 14/ 6/2020 7:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 28 14.95 481 2 2
2 12 1132.56 2 15.10 2051 2 2
3 7 2003.72 40 14.56 3090 2 2
4 13 1737.24 19 14.57 2791 2 2
5 13 1163.92 19 14.66 1982 2 2
6 13 579.60 19 14.83 1187 2 2
7 13 91.20 19 15.00 485 2 2
8 8 0.04 170 14.99 338 2 2

Cycle 88 GMT 4/ 6/2020 7: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 28 14.95 483 2 2
2 12 1137.32 2 15.09 2041 2 2
3 7 2006.16 40 14.56 3083 2 2
4 13 1606.20 19 14.60 2608 2 2
5 13 918.64 19 14.74 1648 2 2
6 13 520.64 19 14.85 1112 2 2
7 13 122.44 19 14.99 541 2 2
8 8 0.20 170 14.99 337 2 3

Cycle 87 GMT 25/ 5/2020 6:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 28 14.95 493 2 2
2 12 1133.24 2 15.10 2031 2 2
3 7 2001.04 40 14.56 3068 2 2
4 13 1463.32 19 14.64 2369 2 2
5 13 1056.80 19 14.71 1813 2 2
6 13 493.20 19 14.86 1067 2 2
7 13 105.24 19 15.00 506 2 2
8 8 0.16 170 14.99 335 2 3

Cycle 86 GMT 15/ 5/2020 6:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 14.96 489 2 2
2 12 1128.44 2 15.10 2033 2 2
3 7 2004.92 40 14.56 3085 2 2
4 13 1738.60 19 14.57 2775 2 2
5 13 1165.00 19 14.66 1994 2 2
6 13 587.80 19 14.83 1198 2 2
7 13 146.76 19 14.98 571 2 2
8 8 0.12 170 14.99 338 2 3

Cycle 85 GMT 5/ 5/2020 5:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 14.96 487 2 2
2 12 1131.32 2 15.11 2035 2 2
3 7 2002.60 41 14.56 3068 2 2
4 13 1462.72 19 14.64 2385 2 2
5 13 1038.68 19 14.71 1769 2 2
6 13 470.08 19 14.87 1030 2 2
7 13 105.44 19 15.00 509 2 2
8 8 0.12 170 14.99 336 2 2

Cycle 84 GMT 25/ 4/2020 5:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 14.96 488 2 2
2 12 1126.68 2 15.11 2034 2 2
3 7 2004.28 41 14.55 3077 2 2
4 13 1732.60 19 14.58 2742 2 2
5 13 1303.24 19 14.63 2181 2 2
6 13 550.88 19 14.84 1150 2 2
7 13 129.84 19 14.99 550 2 2
8 8 0.00 170 14.99 335 2 3

Cycle 83 GMT 15/ 4/2020 5:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 14.95 493 2 2
2 12 1119.48 2 15.10 2019 2 2
3 7 2003.76 40 14.56 3082 2 2
4 13 1734.40 19 14.58 2785 2 2
5 13 1164.04 19 14.67 1991 2 2
6 13 577.44 19 14.84 1191 2 2
7 13 144.44 19 14.98 576 2 2
8 8 0.20 170 14.99 340 2 3

Cycle 82 GMT 5/ 4/2020 4:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 28 14.96 484 2 2
2 12 1241.68 2 15.06 2171 2 2
3 7 2001.76 41 14.56 3067 2 2
4 13 1576.48 19 14.61 2570 2 2
5 13 1128.28 19 14.68 1953 2 2
6 13 543.52 19 14.85 1145 2 2
7 13 129.12 19 14.99 550 2 2
8 8 -0.08 170 14.99 341 2 6

Cycle 81 GMT 26/ 3/2020 4: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 28 14.96 485 2 2
2 12 1140.68 2 15.10 2050 2 2
3 7 2002.56 40 14.56 3082 2 2
4 13 1598.92 19 14.61 2591 2 2
5 13 1033.68 19 14.71 1803 2 2
6 13 606.04 19 14.82 1233 2 2
7 13 157.64 19 14.98 591 2 2
8 8 0.04 170 14.99 340 2 2

Cycle 80 GMT 16/ 3/2020 3:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 14.96 491 2 2
2 12 1142.24 2 15.12 2030 2 2
3 7 2003.04 40 14.55 3072 2 2
4 13 1732.00 19 14.58 2742 2 2
5 13 1011.48 19 14.73 1753 2 2
6 13 586.48 19 14.83 1201 2 2
7 13 149.44 19 14.98 581 2 2
8 8 0.08 170 14.99 341 2 2

Cycle 79 GMT 6/ 3/2020 3:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 14.96 489 2 2
2 12 1142.48 2 15.09 2051 2 2
3 7 2005.48 40 14.56 3088 2 2
4 13 1466.60 19 14.62 2422 2 2
5 13 1057.68 19 14.70 1846 2 2
6 13 493.60 19 14.86 1062 2 2
7 13 114.80 19 15.00 518 2 2
8 8 0.04 170 15.00 334 2 3

Cycle 78 GMT 25/ 2/2020 2:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.96 487 2 2
2 12 1126.80 2 15.11 2030 2 2
3 7 2001.80 41 14.56 3072 2 2
4 13 1736.76 19 14.58 2760 2 2
5 13 1146.16 19 14.69 1937 2 2
6 13 559.64 19 14.84 1169 2 2
7 13 128.04 19 14.99 555 2 2
8 8 0.08 170 14.99 342 2 3

Cycle 77 GMT 15/ 2/2020 2: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 28 14.95 506 2 2
2 12 1131.92 2 15.11 2037 2 2
3 7 2007.20 40 14.57 3079 2 2
4 13 1603.32 19 14.61 2594 2 2
5 13 1029.28 19 14.71 1801 2 2
6 13 600.84 19 14.83 1222 2 2
7 13 160.68 19 14.97 603 2 2
8 8 0.08 170 14.99 342 2 4

Cycle 76 GMT 5/ 2/2020 1:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 28 14.96 483 2 2
2 12 1243.96 2 15.08 2179 2 2
3 7 2001.88 40 14.57 3084 2 2
4 13 1591.28 19 14.61 2601 2 2
5 13 1033.32 19 14.72 1804 2 2
6 13 605.76 19 14.82 1226 2 2
7 13 165.64 19 14.98 605 2 2
8 8 0.20 170 14.99 340 2 2

Cycle 75 GMT 26/ 1/2020 1:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 28 14.95 509 2 2
2 3 1018.04 1 15.07 1894 2 2
3 12 1131.68 2 15.12 2023 2 2
4 7 2004.04 40 14.56 3076 2 2
5 13 1609.88 19 14.61 2581 2 2
6 13 1180.72 19 14.68 1981 2 2
7 13 463.36 19 14.88 1015 2 2
8 13 110.12 19 15.00 517 2 2
9 8 0.16 170 14.99 341 2 3

Cycle 74 GMT 16/ 1/2020 1: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 14.96 485 2 2
2 12 1132.92 2 15.10 2038 2 2
3 7 2004.64 40 14.57 3087 2 2
4 13 1607.00 19 14.61 2574 2 2
5 13 1185.16 19 14.68 1992 2 2
6 13 473.92 19 14.87 1045 2 2
7 13 102.76 19 15.00 504 2 2
8 8 -0.24 170 14.99 339 2 6

Cycle 73 GMT 6/ 1/2020 0:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 28 14.96 488 2 2
2 12 1125.60 2 15.11 2051 2 2
3 7 2003.04 40 14.58 3076 2 2
4 13 1727.76 19 14.60 2746 2 2
5 13 1024.28 19 14.72 1797 2 2
6 13 607.32 19 14.83 1236 2 2
7 13 95.96 19 15.01 501 2 2
8 8 0.20 170 15.00 342 2 3

Cycle 72 GMT 26/12/2019 23:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 14.97 495 2 2
2 12 1237.40 2 15.09 2184 2 2
3 7 2003.36 40 14.57 3084 2 2
4 13 1734.92 19 14.59 2752 2 2
5 13 1175.84 19 14.68 2009 2 2
6 13 603.76 19 14.83 1223 2 2
7 13 100.04 19 15.01 500 2 2
8 8 0.16 170 15.00 339 2 3

Cycle 71 GMT 16/12/2019 22:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 28 14.97 473 2 2
2 12 1131.52 2 15.13 2020 2 2
3 7 2002.68 40 14.58 3075 2 2
4 13 1602.32 19 14.62 2603 2 2
5 13 1191.80 19 14.67 2031 2 2
6 13 589.96 19 14.84 1204 2 2
7 13 92.68 19 15.02 486 2 2
8 8 0.12 170 15.00 337 2 4

Cycle 70 GMT 6/12/2019 22:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 28 14.97 487 2 2
2 12 1133.04 2 15.11 2043 2 2
3 7 2003.36 40 14.57 3082 2 2
4 13 1596.20 19 14.61 2600 2 2
5 13 1034.96 19 14.72 1810 2 2
6 13 474.08 19 14.88 1047 2 2
7 13 103.60 19 15.01 502 2 2
8 13 13.12 19 15.04 357 2 2
9 8 -0.16 170 15.00 336 2 5

Cycle 69 GMT 26/11/2019 21:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 28 14.98 479 2 2
2 12 1138.04 2 15.11 2036 2 2
3 7 2001.60 40 14.58 3091 2 2
4 13 1597.88 19 14.62 2612 2 2
5 13 1050.88 19 14.71 1841 2 2
6 13 630.00 19 14.83 1268 2 2
7 13 107.80 19 15.01 519 2 2
8 13 27.04 19 15.04 388 2 2
9 8 0.04 170 15.00 338 2 3

Cycle 68 GMT 16/11/2019 20:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 14.98 482 2 2
2 12 1132.40 2 15.11 2023 2 2
3 7 2002.76 40 14.58 3077 2 2
4 13 1730.60 19 14.61 2756 2 2
5 13 1026.24 19 14.75 1774 2 2
6 13 474.80 19 14.89 1046 2 2
7 13 104.72 19 15.02 513 2 2
8 8 0.00 170 15.02 335 2 2

Cycle 67 GMT 6/11/2019 20: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 28 14.99 486 2 2
2 12 1135.36 2 15.11 2053 2 2
3 7 2002.24 40 14.58 3081 2 2
4 13 1738.80 19 14.61 2761 2 2
5 13 1022.36 19 14.75 1776 2 2
6 13 480.08 19 14.90 1046 2 2
7 13 107.28 19 15.02 518 2 2
8 8 0.00 170 15.02 337 2 3

Cycle 66 GMT 27/10/2019 19:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 14.99 479 2 2
2 12 1126.60 2 15.14 2023 2 2
3 7 2002.72 40 14.58 3083 2 2
4 13 1586.08 19 14.64 2558 2 2
5 13 1012.48 19 14.75 1759 2 2
6 13 469.56 19 14.90 1028 2 2
7 13 97.48 19 15.03 502 2 2
8 8 -0.04 170 15.02 335 2 3

Cycle 65 GMT 17/10/2019 18:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 27 14.99 479 2 2
2 12 1132.56 2 15.12 2042 2 2
3 7 2001.08 40 14.59 3082 2 2
4 13 1595.48 19 14.65 2563 2 2
5 13 1042.88 19 14.75 1790 2 2
6 13 493.28 19 14.90 1066 2 2
7 13 113.92 19 15.03 520 2 2
8 13 27.28 19 15.05 391 2 2
9 8 0.08 170 15.02 336 2 6

Cycle 64 GMT 7/10/2019 17:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 27 15.01 471 2 2
2 12 1131.04 2 15.12 2073 2 2
3 7 2006.96 40 14.59 3088 2 2
4 13 1880.28 19 14.59 2944 2 2
5 13 1132.84 19 14.72 1940 2 2
6 13 565.08 19 14.88 1177 2 2
7 13 142.12 19 15.02 576 2 2
8 13 35.76 19 15.05 404 2 2
9 8 -0.16 170 15.02 340 2 3

Cycle 63 GMT 27/ 9/2019 16:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 15.00 481 2 2
2 12 1239.56 2 15.09 2208 2 2
3 7 2000.96 40 14.59 3074 2 2
4 13 1593.00 19 14.65 2572 2 2
5 13 1043.00 19 14.76 1792 2 2
6 13 478.28 19 14.92 1031 2 2
7 13 106.12 19 15.04 516 2 2
8 13 26.48 19 15.06 388 2 2
9 8 0.12 170 15.03 337 2 4

Cycle 62 GMT 17/ 9/2019 16:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 27 15.01 477 2 2
2 12 1129.56 2 15.14 2012 2 2
3 7 2003.80 40 14.59 3092 2 2
4 13 1600.52 19 14.65 2578 2 2
5 13 1161.04 19 14.72 1994 2 2
6 13 452.76 19 14.93 1017 2 2
7 13 93.80 19 15.05 498 2 2
8 13 24.92 19 15.07 390 2 2
9 8 0.00 170 15.04 340 2 2

Cycle 61 GMT 7/ 9/2019 15:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 27 15.02 480 2 2
2 12 1122.40 2 15.13 2039 2 2
3 7 2004.44 40 14.59 3088 2 2
4 13 1470.40 19 14.68 2393 2 2
5 13 1184.92 19 14.71 1996 2 2
6 13 470.40 19 14.93 1015 2 2
7 13 97.32 19 15.05 497 2 2
8 13 24.92 19 15.07 390 2 2
9 8 0.12 170 15.03 343 2 3

Cycle 60 GMT 28/ 8/2019 15: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 27 15.02 475 2 2
2 12 1118.68 2 15.15 2011 2 2
3 7 2001.28 40 14.60 3077 2 2
4 13 1468.80 19 14.69 2393 2 2
5 13 937.16 19 14.81 1657 2 2
6 13 397.84 19 14.96 932 2 2
7 13 72.40 19 15.07 462 2 2
8 13 21.44 19 15.08 381 2 2
9 8 -0.04 170 15.05 338 2 3

Cycle 59 GMT 18/ 8/2019 14:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 27 15.02 481 2 2
2 12 1126.32 2 15.15 2023 2 2
3 7 2004.88 40 14.60 3081 2 2
4 13 1737.64 19 14.63 2781 2 2
5 13 1039.60 19 14.77 1832 2 2
6 13 490.32 19 14.93 1080 2 2
7 13 109.52 19 15.06 525 2 2
8 13 14.20 19 15.09 376 2 2
9 8 -0.04 170 15.05 345 2 2

Cycle 58 GMT 8/ 8/2019 13:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 27 15.02 491 2 2
2 12 1130.04 2 15.13 2030 2 2
3 7 2000.32 40 14.60 3071 2 2
4 13 1590.36 19 14.67 2569 2 2
5 13 1147.72 19 14.74 1972 2 2
6 13 566.16 19 14.91 1184 2 2
7 13 132.12 19 15.05 564 2 2
8 13 12.92 19 15.09 370 2 2
9 8 -0.08 170 15.05 345 2 3

Cycle 57 GMT 29/ 7/2019 12:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 15.04 473 2 2
2 12 1130.52 2 15.14 2040 2 2
3 7 2003.12 41 14.60 3070 2 2
4 13 1725.40 19 14.64 2743 2 2
5 13 1007.12 19 14.81 1742 2 2
6 13 584.12 19 14.91 1201 2 2
7 13 136.52 19 15.06 560 2 2
8 13 16.40 19 15.10 375 2 2
9 8 0.08 170 15.06 343 2 3

Cycle 56 GMT 19/ 7/2019 11:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 27 15.05 474 2 2
2 12 1122.96 2 15.16 2009 2 2
3 7 2008.16 40 14.60 3086 2 2
4 13 1599.68 19 14.67 2592 2 2
5 13 1038.68 19 14.78 1832 2 2
6 13 476.72 19 14.95 1055 2 2
7 13 95.64 19 15.08 503 2 2
8 13 20.88 19 15.10 381 2 2
9 8 0.12 170 15.06 340 2 5

Cycle 55 GMT 9/ 7/2019 10:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 15.05 485 2 2
2 3 1019.52 1 15.12 1909 2 2
3 12 1117.44 2 15.16 2026 2 2
4 7 2001.56 41 14.61 3072 2 2
5 13 1477.84 19 14.71 2398 2 2
6 13 928.12 19 14.84 1647 2 2
7 13 499.96 19 14.95 1083 2 2
8 13 99.60 19 15.09 503 2 2
9 8 0.00 170 15.08 338 2 6

Cycle 54 GMT 29/ 6/2019 10: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 27 15.05 489 2 2
2 12 1137.52 2 15.16 2036 2 2
3 7 2001.00 40 14.62 3073 2 2
4 13 1603.48 19 14.68 2597 2 2
5 13 1039.08 19 14.80 1829 2 2
6 13 495.84 19 14.96 1086 2 2
7 13 109.32 19 15.09 522 2 2
8 8 0.04 170 15.09 343 2 3

Cycle 53 GMT 19/ 6/2019 9:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 27 15.06 493 2 2
2 3 1018.52 1 15.13 1882 2 2
3 12 1128.76 2 15.15 2041 2 2
4 7 2003.48 40 14.61 3080 2 2
5 13 1593.44 19 14.68 2603 2 2
6 13 1036.12 19 14.81 1819 2 2
7 13 480.28 19 14.97 1060 2 2
8 13 106.40 19 15.10 516 2 2
9 8 0.12 170 15.09 340 2 3

Cycle 52 GMT 9/ 6/2019 8:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 27 15.06 492 2 2
2 12 1121.72 2 15.16 2020 2 2
3 7 2000.88 41 14.62 3071 2 2
4 13 1730.56 19 14.66 2735 2 2
5 13 1005.76 19 14.83 1754 2 2
6 13 440.60 19 14.99 1005 2 2
7 13 86.16 19 15.11 488 2 2
8 8 0.16 170 15.10 344 2 2

Cycle 51 GMT 30/ 5/2019 7:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 27 15.07 504 2 2
2 12 1241.32 2 15.12 2209 2 2
3 7 2002.24 40 14.62 3077 2 2
4 13 1731.60 19 14.67 2745 2 2
5 13 1138.24 19 14.80 1932 2 2
6 13 555.96 19 14.96 1160 2 2
7 13 135.24 19 15.10 561 2 2
8 8 0.12 170 15.10 343 2 3

Cycle 50 GMT 20/ 5/2019 7: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 27 15.07 485 2 2
2 12 1132.40 2 15.15 2047 2 2
3 7 2001.28 40 14.62 3082 2 2
4 13 1588.72 19 14.71 2549 2 2
5 13 1020.92 19 14.84 1768 2 2
6 13 463.12 19 14.99 1033 2 2
7 13 96.96 19 15.11 504 2 2
8 8 0.08 170 15.11 338 2 4

Cycle 49 GMT 10/ 5/2019 6:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 27 15.07 492 2 2
2 12 1125.52 2 15.18 2027 2 2
3 7 2001.20 40 14.62 3074 2 2
4 13 1737.20 19 14.67 2749 2 2
5 13 888.52 19 14.88 1611 2 2
6 13 601.56 19 14.95 1234 2 2
7 13 78.72 19 15.12 480 2 2
8 8 0.12 170 15.10 347 2 2

Cycle 48 GMT 30/ 4/2019 5:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 27 15.08 496 2 2
2 12 1120.80 2 15.16 2025 2 2
3 7 2010.12 40 14.63 3087 2 2
4 13 1612.52 19 14.70 2607 2 2
5 13 1322.60 19 14.74 2184 2 2
6 13 574.04 19 14.97 1165 2 2
7 13 142.56 19 15.11 572 2 2
8 8 0.00 170 15.11 341 2 3

Cycle 47 GMT 20/ 4/2019 4:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 27 15.07 510 2 2
2 12 1236.60 2 15.13 2211 2 2
3 7 2002.88 40 14.63 3077 2 2
4 13 1605.92 19 14.70 2596 2 2
5 13 1175.56 19 14.79 2018 2 2
6 13 577.12 19 14.96 1202 2 2
7 13 86.84 19 15.13 484 2 2
8 8 0.00 170 15.12 344 2 4

Cycle 46 GMT 10/ 4/2019 3:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 27 15.08 501 2 2
2 3 1019.16 1 15.14 1899 2 2
3 12 1238.92 2 15.13 2193 2 2
4 7 2007.24 40 14.63 3087 2 2
5 13 1745.92 19 14.67 2784 2 2
6 13 1165.00 19 14.81 1986 2 2
7 13 563.04 19 14.98 1172 2 2
8 13 125.88 19 15.12 551 2 2
9 8 0.24 170 15.12 347 2 3

Cycle 45 GMT 31/ 3/2019 2:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 27 15.09 500 2 2
2 12 1124.08 2 15.17 2030 2 2
3 7 2000.72 40 14.64 3065 2 2
4 13 1597.16 19 14.72 2590 2 2
5 13 1016.44 19 14.85 1793 2 2
6 13 460.88 19 15.01 1028 2 2
7 13 92.64 19 15.14 490 2 2
8 8 0.04 170 15.12 343 2 4

Cycle 44 GMT 21/ 3/2019 1:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 27 15.09 503 2 2
2 3 1021.36 1 15.15 1895 2 2
3 12 1136.96 2 15.17 2042 2 2
4 7 2002.92 40 14.65 3074 2 2
5 13 1466.92 19 14.77 2390 2 2
6 13 921.60 19 14.90 1636 2 2
7 13 518.84 19 15.00 1110 2 2
8 13 118.28 19 15.13 531 2 2
9 8 -0.08 170 15.13 346 2 5

Cycle 43 GMT 11/ 3/2019 1:20: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 15.09 503 2 2
2 12 1129.64 2 15.19 2024 2 2
3 7 2009.24 40 14.64 3084 2 2
4 13 1747.08 19 14.69 2771 2 2
5 13 1016.24 19 14.87 1770 2 2
6 13 589.40 19 14.97 1222 2 2
7 13 148.88 19 15.12 592 2 2
8 8 0.28 170 15.13 353 2 2

Cycle 42 GMT 28/ 2/2019 23:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 27 15.09 505 2 2
2 12 1120.00 2 15.19 2020 2 2
3 7 2002.64 40 14.64 3080 2 2
4 13 1587.64 19 14.74 2560 2 2
5 13 1035.36 19 14.86 1811 2 2
6 13 467.92 19 15.02 1045 2 2
7 13 95.96 19 15.14 501 2 2
8 8 -0.16 170 15.13 348 2 3

Cycle 41 GMT 18/ 2/2019 22:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 27 15.09 503 2 2
2 3 1019.04 1 15.15 1882 2 2
3 12 1126.28 2 15.18 2032 2 2
4 7 2002.88 40 14.66 3076 2 2
5 13 1603.16 19 14.73 2601 2 2
6 13 1176.52 19 14.81 2024 2 2
7 13 597.04 19 14.97 1227 2 2
8 13 158.96 19 15.12 607 2 2
9 8 0.24 170 15.13 353 2 2

Cycle 40 GMT 8/ 2/2019 21:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 27 15.10 502 2 2
2 12 1132.40 2 15.18 2047 2 2
3 7 2005.96 41 14.65 3079 2 2
4 13 1452.20 19 14.77 2386 2 2
5 13 1020.20 19 14.87 1795 2 2
6 13 463.96 19 15.03 1044 2 2
7 13 91.48 19 15.15 504 2 2
8 8 0.04 170 15.13 355 2 4

Cycle 39 GMT 29/ 1/2019 20:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 27 15.10 503 2 2
2 3 1020.00 1 15.17 1893 2 2
3 12 1127.84 2 15.19 2026 2 2
4 7 2002.40 40 14.66 3082 2 2
5 13 1586.72 19 14.73 2595 2 2
6 13 1027.60 19 14.87 1810 2 2
7 13 599.88 19 14.98 1228 2 2
8 13 155.68 19 15.13 600 2 2
9 8 0.08 170 15.13 354 2 4

Cycle 38 GMT 19/ 1/2019 19:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 27 15.11 504 2 2
2 12 1245.96 2 15.14 2194 2 2
3 7 2004.40 40 14.65 3080 2 2
4 13 1589.60 19 14.75 2559 2 2
5 13 887.68 19 14.92 1610 2 2
6 13 598.52 19 14.99 1226 2 2
7 13 79.64 19 15.16 480 2 2
8 8 0.08 170 15.14 353 2 3

Cycle 37 GMT 9/ 1/2019 19:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 27 15.11 516 2 2
2 12 1226.92 2 15.15 2196 2 2
3 7 2003.88 40 14.65 3077 2 2
4 13 1742.64 19 14.71 2776 2 2
5 13 1013.80 19 14.89 1772 2 2
6 13 454.60 19 15.04 1030 2 2
7 13 86.44 19 15.16 498 2 2
8 8 -0.04 170 15.14 355 2 4

Cycle 36 GMT 30/12/2018 18:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 27 15.12 494 2 2
2 12 1129.92 2 15.19 2031 2 2
3 7 2006.08 40 14.66 3079 2 2
4 13 1739.56 19 14.71 2767 2 2
5 13 1143.64 19 14.84 1970 2 2
6 13 442.84 19 15.05 1008 2 2
7 13 85.32 19 15.17 490 2 2
8 8 0.20 170 15.15 351 2 3

Cycle 35 GMT 20/12/2018 17:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 27 15.12 488 2 2
2 3 1019.24 1 15.17 1897 2 2
3 12 1226.84 2 15.18 2189 2 2
4 7 2002.76 40 14.66 3076 2 2
5 13 1593.32 19 14.76 2568 2 2
6 13 1019.36 19 14.89 1770 2 2
7 13 592.40 19 15.00 1221 2 2
8 13 74.28 19 15.17 476 2 2
9 8 0.12 170 15.15 355 2 3

Cycle 34 GMT 10/12/2018 16:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 27 15.12 489 2 2
2 12 1129.44 2 15.19 2028 2 2
3 7 2002.40 40 14.66 3074 2 2
4 13 1579.24 19 14.75 2575 2 2
5 13 1020.80 19 14.88 1815 2 2
6 13 584.76 19 15.00 1215 2 2
7 13 71.52 19 15.18 469 2 2
8 8 0.08 170 15.15 353 2 5

Cycle 33 GMT 30/11/2018 15: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 27 15.13 491 2 2
2 12 1249.16 2 15.17 2228 2 2
3 7 2002.80 40 14.67 3064 2 2
4 13 1595.12 15 14.77 2617 2 2
5 13 1192.88 15 14.85 2055 2 2
6 13 656.88 15 15.00 1308 2 2
7 13 248.92 15 15.12 747 2 2
8 13 63.56 15 15.18 457 2 2
9 8 0.32 170 15.16 352 2 3

Cycle 32 GMT 20/11/2018 13:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 26 15.14 506 2 2
2 3 1021.32 1 15.18 1931 2 2
3 12 1243.00 2 15.16 2204 2 2
4 7 2001.48 40 14.68 3073 2 2
5 13 1596.48 15 14.78 2560 2 2
6 13 1074.68 15 14.90 1852 2 2
7 13 798.28 15 14.97 1474 2 2
8 13 365.72 15 15.08 910 2 2
9 13 109.20 15 15.17 531 2 2
10 8 -0.04 170 15.16 348 2 3

Cycle 31 GMT 10/11/2018 13: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 26 15.14 491 2 2
2 12 1253.40 2 15.17 2226 2 2
3 7 2002.52 40 14.68 3065 2 2
4 13 1597.48 15 14.79 2581 2 2
5 13 1329.92 15 14.82 2217 2 2
6 13 762.96 15 14.98 1428 2 2
7 13 215.16 15 15.15 657 2 2
8 13 57.32 15 15.19 449 2 2
9 8 -0.04 170 15.16 351 2 2

Cycle 30 GMT 31/10/2018 11:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 26 15.14 481 2 2
2 12 1242.84 2 15.17 2207 2 2
3 7 2004.08 40 14.67 3061 2 2
4 13 1738.08 15 14.75 2768 2 2
5 13 1168.28 15 14.88 1980 2 2
6 13 620.80 15 15.03 1226 2 2
7 13 353.92 15 15.10 854 2 2
8 13 52.76 15 15.21 399 2 2
9 8 0.16 170 15.17 346 2 2

Cycle 29 GMT 21/10/2018 10:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 26 15.14 505 2 2
2 12 1245.20 2 15.17 2218 2 2
3 7 1990.56 40 14.68 3062 2 2
4 13 1727.36 15 14.76 2753 2 2
5 13 1158.40 15 14.88 2001 2 2
6 13 739.32 15 14.98 1435 2 2
7 13 318.16 15 15.11 835 2 2
8 13 88.64 15 15.18 499 2 2
9 8 0.08 170 15.17 347 2 3

Cycle 28 GMT 11/10/2018 9:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 26 15.15 505 2 2
2 3 1021.56 1 15.19 1898 2 2
3 12 1254.20 2 15.17 2233 2 2
4 7 2002.88 40 14.68 3074 2 2
5 13 1734.84 15 14.75 2764 2 2
6 13 1008.04 15 14.93 1766 2 2
7 13 604.08 15 15.04 1206 2 2
8 13 207.88 15 15.16 650 2 2
9 13 53.44 15 15.20 442 2 2
10 8 0.20 170 15.17 351 2 5

Cycle 27 GMT 1/10/2018 7:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 26 15.15 497 2 2
2 12 1240.00 2 15.17 2221 2 2
3 7 2002.04 40 14.70 3069 2 2
4 13 1569.44 15 14.82 2542 2 2
5 13 1153.36 15 14.89 1995 2 2
6 13 612.40 15 15.03 1254 2 2
7 13 337.88 15 15.11 868 2 2
8 13 50.52 15 15.21 433 2 2
9 8 0.04 170 15.18 349 2 4

Cycle 26 GMT 21/ 9/2018 6:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 26 15.15 492 2 2
2 3 1019.84 1 15.20 1904 2 2
3 12 1237.28 2 15.18 2215 2 2
4 7 1995.40 40 14.70 3056 2 2
5 13 1730.04 15 14.77 2743 2 2
6 13 1131.16 15 14.90 1934 2 2
7 13 735.60 15 15.00 1419 2 2
8 13 442.96 15 15.07 1011 2 2
9 13 74.68 15 15.20 468 2 2
10 8 0.08 170 15.18 348 2 3

Cycle 25 GMT 11/ 9/2018 5:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 26 15.16 495 2 2
2 12 1241.40 2 15.19 2192 2 2
3 7 1994.76 40 14.70 3067 2 2
4 13 1716.56 15 14.78 2738 2 2
5 13 1011.32 15 14.95 1761 2 2
6 13 606.56 15 15.05 1212 2 2
7 13 334.16 15 15.12 823 2 2
8 13 95.36 15 15.20 476 2 2
9 13 19.40 15 15.22 388 2 2
10 8 0.08 170 15.18 349 2 3

Cycle 24 GMT 1/ 9/2018 3:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 26 15.15 496 2 2
2 3 1019.56 1 15.20 1914 2 2
3 12 1236.20 2 15.19 2200 2 2
4 7 2001.24 40 14.70 3079 2 2
5 13 1596.76 15 14.80 2589 2 2
6 13 1200.04 15 14.89 2032 2 2
7 13 630.96 15 15.04 1245 2 2
8 13 219.24 15 15.17 663 2 2
9 13 33.88 15 15.22 403 2 2
10 8 0.08 170 15.19 350 2 3

Cycle 23 GMT 22/ 8/2018 2:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 26 15.16 489 2 2
2 12 1251.76 3 15.17 2203 2 2
3 7 1957.84 35 14.74 3035 2 2
4 13 1689.84 15 14.80 2712 2 2
5 13 1028.36 15 14.95 1813 2 2
6 13 765.68 15 15.00 1468 2 2
7 13 478.72 15 15.08 1068 2 2
8 13 89.68 15 15.20 503 2 2
9 13 23.88 15 15.22 398 2 2
10 8 0.00 170 15.18 352 2 3

Cycle 22 GMT 12/ 8/2018 0:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 26 15.16 492 2 2
2 12 1239.24 3 15.17 2190 2 2
3 7 1958.16 35 14.75 3034 2 2
4 13 1699.16 15 14.80 2721 2 2
5 13 1271.76 15 14.89 2136 2 2
6 13 728.24 15 15.02 1381 2 2
7 13 318.84 15 15.14 838 2 2
8 13 94.48 15 15.21 515 2 2
9 13 22.76 15 15.22 398 2 2
10 8 0.04 170 15.19 351 2 3

Cycle 21 GMT 1/ 8/2018 23:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 26 15.17 504 2 2
2 12 1248.68 3 15.17 2193 2 2
3 7 1970.68 35 14.75 3034 2 2
4 13 1846.44 15 14.78 2923 2 2
5 13 1138.72 15 14.93 1943 2 2
6 13 733.92 15 15.03 1400 2 2
7 13 461.00 15 15.09 1042 2 2
8 13 85.92 15 15.21 502 2 2
9 13 20.40 15 15.23 392 2 2
10 8 0.04 170 15.19 351 2 3

Cycle 20 GMT 22/ 7/2018 21:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 26 15.18 491 2 2
2 7 2003.08 43 14.71 3069 2 2
3 13 1719.96 15 14.80 2735 2 2
4 13 1005.56 15 14.96 1762 2 2
5 13 591.16 15 15.06 1219 2 2
6 13 184.84 15 15.19 649 2 2
7 13 25.28 15 15.24 401 2 2
8 8 0.16 170 15.20 349 2 2

Cycle 19 GMT 12/ 7/2018 21:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 26 15.17 503 2 2
2 7 2003.04 42 14.72 3077 2 2
3 13 1474.84 15 14.86 2411 2 2
4 13 1074.00 15 14.94 1855 2 2
5 13 662.72 15 15.04 1306 2 2
6 13 240.84 15 15.17 731 2 2
7 13 33.52 15 15.23 412 2 2
8 8 0.00 170 15.20 349 2 3

Cycle 18 GMT 2/ 7/2018 21: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 26 15.18 487 2 2
2 7 2004.04 42 14.73 3084 2 2
3 13 1464.32 15 14.87 2409 2 2
4 13 954.52 15 14.99 1688 2 2
5 13 664.16 15 15.05 1292 2 2
6 13 250.96 15 15.17 725 2 2
7 13 56.44 15 15.23 444 2 2
8 8 0.20 170 15.20 353 2 3

Cycle 17 GMT 22/ 6/2018 20:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 26 15.18 497 2 2
2 7 2002.60 42 14.73 3080 2 2
3 13 1598.20 15 14.85 2587 2 2
4 13 1032.04 15 14.97 1820 2 2
5 13 615.24 15 15.07 1253 2 2
6 13 204.08 15 15.19 682 2 2
7 13 50.60 15 15.23 446 2 2
8 8 0.08 170 15.21 357 2 4

Cycle 16 GMT 12/ 6/2018 20:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 26 15.18 489 2 2
2 7 2004.04 42 14.74 3078 2 2
3 13 1466.28 15 14.88 2403 2 2
4 13 1068.12 15 14.95 1858 2 2
5 13 653.40 15 15.06 1282 2 2
6 13 237.44 15 15.18 712 2 2
7 13 30.36 15 15.25 408 2 2
8 8 0.16 170 15.21 353 2 4

Cycle 15 GMT 2/ 6/2018 19:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 26 15.19 512 2 2
2 3 1019.68 1 15.23 1912 2 2
3 7 2002.08 42 14.75 3073 2 2
4 13 1583.92 15 14.85 2575 2 2
5 13 1167.80 15 14.93 1985 2 2
6 13 616.20 15 15.08 1233 2 2
7 13 200.24 15 15.20 676 2 2
8 13 50.88 15 15.24 446 2 2
9 8 0.20 170 15.21 352 2 3

Cycle 14 GMT 23/ 5/2018 19:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 26 15.18 493 2 2
2 3 1023.72 1 15.23 1896 2 2
3 7 2003.92 42 14.75 3076 2 2
4 13 1455.48 15 14.89 2392 2 2
5 13 1185.00 15 14.93 2003 2 2
6 13 631.24 15 15.08 1261 2 2
7 13 215.92 15 15.19 693 2 2
8 13 52.80 15 15.24 451 2 2
9 8 0.08 170 15.22 357 2 2

Cycle 13 GMT 13/ 5/2018 19:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 26 15.18 516 2 2
2 3 1020.16 1 15.23 1914 2 2
3 7 2003.88 42 14.76 3074 2 2
4 13 1589.84 15 14.87 2568 2 2
5 13 1038.56 15 14.98 1803 2 2
6 13 628.16 15 15.08 1249 2 2
7 13 209.84 15 15.20 692 2 2
8 13 50.40 15 15.25 444 2 2
9 8 0.04 170 15.21 359 2 4

Cycle 12 GMT 3/ 5/2018 19: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 25 15.19 503 2 2
2 3 1022.40 1 15.23 1888 2 2
3 7 2005.72 42 14.76 3068 2 2
4 13 1726.76 15 14.84 2735 2 2
5 13 1146.04 15 14.95 1947 2 2
6 13 600.96 15 15.09 1200 2 2
7 13 195.00 15 15.21 643 2 2
8 13 45.20 15 15.25 432 2 2
9 8 0.12 170 15.22 353 2 4

Cycle 11 GMT 23/ 4/2018 18:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 25 15.19 516 2 2
2 3 1033.68 1 15.22 1899 2 2
3 7 2001.96 42 14.77 3072 2 2
4 13 1719.56 15 14.84 2741 2 2
5 13 1023.72 15 14.99 1792 2 2
6 13 625.88 15 15.09 1241 2 2
7 13 211.68 15 15.20 685 2 2
8 13 24.52 15 15.26 391 2 2
9 8 0.04 170 15.23 341 2 4

Cycle 10 GMT 13/ 4/2018 18:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 25 15.19 482 2 2
2 3 1031.44 1 15.22 1924 2 2
3 7 2002.48 36 14.80 3080 2 2
4 13 1604.00 18 14.87 2585 2 2
5 13 1043.24 18 14.98 1808 2 2
6 13 765.48 18 15.03 1456 2 2
7 13 167.92 18 15.21 624 2 2
8 8 0.20 165 15.23 351 2 3

Cycle 9 GMT 3/ 4/2018 18:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 25 15.18 514 2 2
2 3 1036.44 1 15.22 1904 2 2
3 7 2001.52 36 14.80 3073 2 2
4 13 1743.40 18 14.85 2778 2 2
5 13 1197.88 18 14.93 2036 2 2
6 13 631.48 18 15.07 1274 2 2
7 13 110.24 18 15.24 526 2 2
8 8 0.04 165 15.24 338 2 3

Cycle 8 GMT 24/ 3/2018 18:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 25 15.20 472 2 2
2 3 1049.96 1 15.20 1918 2 2
3 7 2003.96 36 14.80 3077 2 2
4 13 1884.48 18 14.82 2941 2 2
5 13 1742.44 18 14.80 2792 2 2
6 13 907.68 18 14.99 1646 2 2
7 13 435.44 18 15.13 999 2 2
8 13 70.52 18 15.24 477 2 2
9 8 0.16 165 15.22 353 2 2

Cycle 7 GMT 14/ 3/2018 18:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 24 15.19 488 2 2
2 3 1063.20 2 15.17 1936 2 2
3 7 2002.40 37 14.81 3064 2 2
4 13 1850.92 18 14.83 2907 2 2
5 13 1545.72 18 14.86 2506 2 2
6 13 895.44 18 15.01 1620 2 2
7 13 416.16 18 15.14 959 2 2
8 13 125.12 18 15.23 544 2 2
9 8 0.12 165 15.23 332 2 4

Cycle 6 GMT 4/ 3/2018 18:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 24 15.19 476 2 2
2 10 1029.00 2 15.15 1886 2 2
3 7 2003.32 36 14.82 3070 2 2
4 13 1871.68 18 14.84 2928 2 2
5 13 1720.84 18 14.82 2720 2 2
6 13 1054.12 18 14.96 1808 2 2
7 13 408.40 18 15.14 937 2 2
8 13 122.24 18 15.23 541 2 2
9 8 -0.12 165 15.23 333 2 4

Cycle 5 GMT 22/ 2/2018 19: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 23 15.22 451 2 2
2 3 1070.88 2 15.18 1942 2 2
3 7 2006.32 36 14.82 3081 2 2
4 13 1874.36 18 14.83 2931 2 2
5 13 1416.12 18 14.89 2324 2 2
6 13 1099.04 18 14.95 1872 2 2
7 13 444.00 18 15.13 987 2 2
8 13 68.84 18 15.25 447 2 2
9 8 0.12 165 15.23 339 2 4

Cycle 4 GMT 12/ 2/2018 19: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 24 15.21 464 2 2
2 7 1512.28 36 14.97 2421 2 2
3 13 1399.16 18 14.98 2293 2 2
4 13 1252.80 18 14.97 2076 2 2
5 13 775.40 18 15.07 1421 2 2
6 13 290.88 18 15.20 749 2 2
7 13 67.16 18 15.26 420 2 2
8 8 0.12 165 15.25 310 2 3

Cycle 3 GMT 11/ 2/2018 19:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 24 15.21 473 2 2
2 7 1515.00 36 14.97 2420 2 2
3 13 1400.24 18 14.97 2291 2 2
4 13 1258.20 18 14.96 2087 2 2
5 13 794.32 18 15.06 1455 2 2
6 13 291.56 18 15.19 751 2 2
7 13 64.84 18 15.26 419 2 2
8 8 0.08 165 15.24 309 2 3

Cycle 2 GMT 10/ 2/2018 20:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 24 15.23 467 2 2
2 7 1506.04 74 14.86 2409 2 2
3 13 428.68 22 15.16 946 2 2
4 13 69.24 22 15.26 425 2 2
5 8 0.12 165 15.25 311 2 3

Cycle 1 GMT 9/ 2/2018 20:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 23 15.42 458 2 2
2 3 1059.88 2 15.20 1940 2 2
3 7 1007.04 74 15.02 1749 2 2
4 8 0.16 240 15.27 318 2 6

Cycle 0 GMT 9/ 2/2018 9:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 139.52 22 15.57 501 2 2
2 7 150.12 74 15.53 509 2 2
3 8 0.20 240 15.49 287 2 5