SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8762 WMO= 4903014


Cycle 215 GMT 20/12/2024 11:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 31 14.85 469 2 3
2 7 2011.88 33 14.64 2982 2 3
3 13 1485.40 20 14.66 2344 2 4
4 13 921.92 20 14.72 1629 2 8
5 13 481.88 20 14.79 1045 2 4
6 13 85.28 20 14.90 491 2 3
7 8 0.04 165 14.88 345 2 11

Cycle 214 GMT 10/12/2024 13:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 31 14.85 493 2 3
2 7 2007.72 34 14.64 2990 2 3
3 13 1583.28 20 14.66 2464 2 5
4 13 1008.60 20 14.69 1755 2 4
5 13 431.52 20 14.81 978 2 5
6 13 71.32 20 14.91 470 2 3
7 8 0.24 165 14.89 348 2 7

Cycle 213 GMT 30/11/2024 15:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 14.86 493 2 3
2 7 2003.72 33 14.66 2975 2 3
3 13 1591.56 20 14.66 2483 2 4
4 13 1013.16 20 14.70 1749 2 4
5 13 450.52 20 14.80 1019 2 5
6 13 82.56 20 14.90 475 2 3
7 8 0.00 165 14.89 346 2 8

Cycle 212 GMT 20/11/2024 17:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 31 14.86 483 2 3
2 7 2010.12 33 14.65 2988 2 3
3 13 1602.72 20 14.66 2505 2 3
4 13 1027.68 20 14.70 1777 2 4
5 13 456.60 20 14.80 1013 2 3
6 13 86.48 20 14.90 501 2 3
7 8 -0.08 165 14.89 356 2 10

Cycle 211 GMT 10/11/2024 19:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 14.86 484 2 3
2 7 2009.44 34 14.65 2981 2 5
3 13 1597.36 20 14.65 2515 2 5
4 13 1016.12 20 14.70 1755 2 4
5 13 433.72 20 14.81 984 2 5
6 13 71.12 20 14.91 462 2 3
7 8 0.00 165 14.89 343 2 9

Cycle 210 GMT 31/10/2024 21:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 31 14.87 493 2 3
2 7 2003.72 33 14.65 2971 2 4
3 13 1585.68 20 14.66 2495 2 4
4 13 993.12 20 14.71 1730 2 4
5 13 427.44 20 14.81 971 2 6
6 13 74.84 20 14.91 466 2 3
7 8 0.16 165 14.89 344 2 9

Cycle 209 GMT 21/10/2024 23:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 31 14.86 484 2 3
2 7 2010.52 34 14.65 2973 2 3
3 13 1591.16 20 14.65 2495 2 5
4 13 996.28 20 14.70 1738 2 5
5 13 421.20 20 14.81 963 2 4
6 13 68.80 20 14.91 448 2 3
7 8 0.04 165 14.90 339 2 8

Cycle 208 GMT 12/10/2024 2: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 31 14.86 520 2 3
2 7 2008.68 33 14.65 2985 2 4
3 13 1590.44 20 14.66 2491 2 4
4 13 1020.08 20 14.70 1766 2 5
5 13 450.96 20 14.80 1014 2 5
6 13 82.64 20 14.91 471 2 3
7 8 -0.04 165 14.89 337 2 8

Cycle 207 GMT 2/10/2024 4:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 31 14.86 493 2 3
2 7 2004.68 33 14.65 2982 2 3
3 13 1593.52 20 14.66 2495 2 4
4 13 1002.60 20 14.71 1749 2 4
5 13 429.80 20 14.81 988 2 4
6 13 77.64 20 14.91 477 2 3
7 8 0.12 165 14.89 345 2 8

Cycle 206 GMT 22/ 9/2024 6:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 31 14.86 503 2 3
2 7 2009.16 33 14.66 2988 2 3
3 13 1580.04 20 14.66 2475 2 4
4 13 998.12 20 14.72 1726 2 5
5 13 434.12 20 14.81 981 2 3
6 13 71.64 20 14.91 456 2 3
7 8 0.04 165 14.89 342 2 10

Cycle 205 GMT 12/ 9/2024 8:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 14.86 482 2 3
2 7 2008.96 33 14.65 2977 2 5
3 13 1592.16 20 14.65 2507 2 5
4 13 997.92 20 14.71 1753 2 5
5 13 433.80 20 14.81 991 2 4
6 13 72.88 20 14.91 480 2 3
7 8 0.08 165 14.89 344 2 11

Cycle 204 GMT 2/ 9/2024 10:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 31 14.86 499 2 3
2 7 2005.36 33 14.66 2973 2 3
3 13 1579.12 20 14.67 2460 2 4
4 13 885.08 20 14.73 1603 2 5
5 13 461.92 20 14.80 1024 2 4
6 13 87.64 20 14.90 496 2 3
7 8 0.04 165 14.89 341 2 7

Cycle 203 GMT 23/ 8/2024 12:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 31 14.86 504 2 3
2 7 2004.20 33 14.66 2964 2 3
3 13 1585.28 20 14.67 2470 2 4
4 13 991.68 20 14.72 1720 2 3
5 13 431.44 20 14.82 976 2 4
6 13 75.12 20 14.92 465 2 3
7 8 0.04 165 14.90 344 2 9

Cycle 202 GMT 13/ 8/2024 14:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 31 14.86 477 2 3
2 7 2006.84 33 14.66 2976 2 3
3 13 1474.00 20 14.69 2337 2 3
4 13 1038.96 20 14.71 1780 2 4
5 13 447.24 20 14.81 1008 2 5
6 13 79.96 20 14.92 466 2 3
7 8 0.08 165 14.90 339 2 8

Cycle 201 GMT 3/ 8/2024 16:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 31 14.87 501 2 3
2 7 2003.00 33 14.67 2958 2 3
3 13 1577.52 20 14.68 2460 2 5
4 13 1001.48 20 14.72 1742 2 4
5 13 431.72 20 14.82 984 2 4
6 13 70.08 20 14.92 454 2 3
7 8 0.00 165 14.90 339 2 8

Cycle 200 GMT 24/ 7/2024 18:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 31 14.86 494 2 3
2 7 2007.12 33 14.66 2972 2 4
3 13 1598.24 20 14.66 2510 2 4
4 13 1010.12 20 14.72 1748 2 5
5 13 443.20 20 14.82 993 2 4
6 13 77.56 20 14.92 463 2 3
7 8 0.12 165 14.90 339 2 14

Cycle 199 GMT 14/ 7/2024 20:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 31 14.86 494 2 3
2 7 2004.56 33 14.67 2954 2 3
3 13 1595.76 20 14.66 2491 2 4
4 13 1027.88 20 14.71 1767 2 5
5 13 441.48 20 14.82 989 2 4
6 13 75.80 20 14.92 459 2 3
7 8 0.12 165 14.90 338 2 9

Cycle 198 GMT 4/ 7/2024 22:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 31 14.86 498 2 3
2 7 2003.84 33 14.66 2962 2 4
3 13 1605.76 20 14.67 2500 2 4
4 13 904.80 20 14.74 1607 2 4
5 13 483.96 20 14.80 1047 2 4
6 13 89.20 20 14.91 486 2 3
7 8 -0.04 165 14.90 345 2 8

Cycle 197 GMT 25/ 6/2024 0:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 31 14.87 503 2 3
2 7 2007.84 33 14.67 2983 2 4
3 13 1595.68 20 14.67 2499 2 5
4 13 1015.68 20 14.72 1750 2 4
5 13 441.48 20 14.82 984 2 4
6 13 75.40 20 14.92 465 2 3
7 8 0.00 165 14.90 340 2 6

Cycle 196 GMT 15/ 6/2024 3: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 14.86 489 2 3
2 7 2003.68 33 14.66 2965 2 3
3 13 1578.16 20 14.67 2464 2 6
4 13 981.68 20 14.72 1717 2 5
5 13 416.56 20 14.83 954 2 5
6 13 67.00 20 14.92 467 2 3
7 8 0.00 165 14.90 348 2 9

Cycle 195 GMT 5/ 6/2024 5:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 14.86 470 2 3
2 7 2005.96 33 14.67 2985 2 3
3 13 1592.88 20 14.67 2498 2 3
4 13 999.20 20 14.72 1731 2 6
5 13 543.12 20 14.79 1131 2 6
6 13 112.88 20 14.90 530 2 3
7 8 0.08 165 14.90 344 2 11

Cycle 194 GMT 26/ 5/2024 7:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 31 14.87 519 2 2
2 7 2005.88 33 14.66 2979 2 3
3 13 1590.44 20 14.67 2477 2 5
4 13 1014.84 20 14.72 1763 2 4
5 13 443.68 20 14.81 992 2 5
6 13 78.36 20 14.92 486 2 3
7 8 0.08 165 14.90 346 2 9

Cycle 193 GMT 16/ 5/2024 9:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 31 14.87 496 2 3
2 7 2007.44 33 14.67 2984 2 3
3 13 1606.32 20 14.67 2512 2 3
4 13 1161.44 20 14.68 1941 2 4
5 13 418.36 20 14.83 959 2 5
6 13 67.80 20 14.92 459 2 3
7 8 0.04 165 14.90 353 2 9

Cycle 192 GMT 6/ 5/2024 11:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 31 14.86 523 2 3
2 7 2005.96 33 14.67 2969 2 3
3 13 1475.88 20 14.69 2333 2 3
4 13 927.20 20 14.73 1643 2 4
5 13 384.52 20 14.83 928 2 4
6 13 55.76 20 14.93 430 2 3
7 8 0.04 165 14.90 340 2 10

Cycle 191 GMT 26/ 4/2024 13:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 31 14.86 522 2 3
2 7 2010.24 33 14.66 2983 2 3
3 13 1469.52 20 14.69 2345 2 5
4 13 929.00 20 14.73 1644 2 5
5 13 384.08 20 14.83 918 2 5
6 13 113.36 20 14.90 530 2 3
7 8 0.12 165 14.90 349 2 8

Cycle 190 GMT 16/ 4/2024 15:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 31 14.87 491 2 2
2 7 2002.80 33 14.68 2973 2 3
3 13 1578.32 20 14.68 2451 2 5
4 13 984.24 20 14.73 1722 2 4
5 13 418.52 20 14.83 975 2 4
6 13 69.20 20 14.92 456 2 3
7 8 -0.12 165 14.90 346 2 10

Cycle 189 GMT 6/ 4/2024 17:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 31 14.86 507 2 3
2 7 2002.72 33 14.67 2967 2 5
3 13 1462.08 20 14.70 2333 2 4
4 13 902.08 20 14.75 1605 2 4
5 13 471.48 20 14.81 1037 2 5
6 13 45.52 20 14.93 431 2 3
7 8 0.16 165 14.90 347 2 13

Cycle 188 GMT 27/ 3/2024 19:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 31 14.87 513 2 3
2 7 2003.00 33 14.68 2987 2 3
3 13 1600.44 20 14.67 2514 2 3
4 13 1012.28 20 14.72 1768 2 4
5 13 553.52 20 14.79 1145 2 4
6 13 114.88 20 14.91 518 2 3
7 8 0.24 165 14.90 344 2 10

Cycle 187 GMT 17/ 3/2024 22: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 31 14.86 508 2 3
2 7 2006.44 33 14.68 2974 2 3
3 13 1584.64 20 14.69 2474 2 3
4 13 1001.48 20 14.73 1752 2 4
5 13 428.20 20 14.83 972 2 5
6 13 135.20 20 14.91 545 2 3
7 8 0.00 165 14.90 344 2 10

Cycle 186 GMT 8/ 3/2024 0:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 31 14.86 511 2 3
2 7 2004.80 33 14.67 2973 2 4
3 13 1592.12 20 14.68 2480 2 4
4 13 1019.92 20 14.72 1771 2 3
5 13 442.64 20 14.83 997 2 6
6 13 76.20 20 14.92 471 2 3
7 8 0.00 165 14.90 348 2 13

Cycle 185 GMT 27/ 2/2024 2:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 31 14.87 508 2 3
2 7 2004.64 33 14.67 2986 2 4
3 13 1588.96 20 14.68 2494 2 5
4 13 1008.72 20 14.72 1766 2 5
5 13 434.60 20 14.83 994 2 5
6 13 141.00 20 14.90 577 2 3
7 8 0.12 165 14.90 346 2 14

Cycle 184 GMT 17/ 2/2024 4:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 14.87 505 2 3
2 7 2003.48 34 14.66 2980 2 4
3 13 1593.88 20 14.67 2484 2 4
4 13 993.04 20 14.73 1721 2 4
5 13 419.56 20 14.83 963 2 4
6 13 64.64 20 14.93 446 2 3
7 8 -0.20 165 14.91 347 2 7

Cycle 183 GMT 7/ 2/2024 6:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 14.87 480 2 3
2 7 2008.84 33 14.68 2964 2 3
3 13 1586.36 20 14.68 2493 2 4
4 13 1005.68 20 14.73 1731 2 4
5 13 555.00 20 14.80 1142 2 5
6 13 120.72 20 14.92 528 2 3
7 8 0.16 165 14.91 343 2 8

Cycle 182 GMT 28/ 1/2024 8:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 31 14.87 497 2 2
2 7 2005.56 33 14.68 2966 2 3
3 13 1584.24 20 14.69 2470 2 5
4 13 991.96 20 14.74 1721 2 4
5 13 430.04 20 14.83 968 2 4
6 13 142.00 20 14.91 563 2 3
7 8 0.12 165 14.91 345 2 9

Cycle 181 GMT 18/ 1/2024 10:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 31 14.88 500 2 3
2 7 2004.56 33 14.68 2973 2 4
3 13 1587.60 20 14.69 2478 2 5
4 13 999.68 20 14.74 1733 2 4
5 13 542.00 20 14.80 1140 2 4
6 13 119.60 20 14.92 537 2 3
7 8 -0.12 165 14.91 348 2 5

Cycle 180 GMT 8/ 1/2024 12:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 31 14.87 518 2 3
2 7 2004.56 33 14.68 2985 2 3
3 13 1732.60 20 14.66 2669 2 4
4 13 1116.88 20 14.71 1890 2 5
5 13 514.16 20 14.81 1105 2 4
6 13 115.36 20 14.92 534 2 3
7 8 0.04 165 14.91 348 2 13

Cycle 179 GMT 29/12/2023 15: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 14.87 481 2 3
2 7 2004.28 33 14.68 2974 2 3
3 13 1597.20 20 14.68 2499 2 3
4 13 1010.72 20 14.73 1755 2 4
5 13 439.28 20 14.83 1000 2 4
6 13 153.80 20 14.90 599 2 4
7 8 0.04 165 14.91 350 2 7

Cycle 178 GMT 19/12/2023 17: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 31 14.87 479 2 3
2 7 2002.76 33 14.68 2997 2 4
3 13 1591.84 20 14.68 2507 2 3
4 13 1002.24 20 14.73 1743 2 6
5 13 446.96 20 14.83 1007 2 4
6 13 94.72 20 14.93 498 2 3
7 8 0.12 165 14.92 338 2 10

Cycle 177 GMT 9/12/2023 19: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 31 14.87 477 2 3
2 7 2002.44 33 14.68 2990 2 3
3 13 1725.92 20 14.66 2679 2 3
4 13 979.96 20 14.74 1727 2 5
5 13 416.72 20 14.84 968 2 4
6 13 136.40 20 14.91 573 2 3
7 8 0.04 165 14.91 347 2 12

Cycle 176 GMT 29/11/2023 21: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 31 14.87 476 2 3
2 7 2004.08 33 14.69 2977 2 3
3 13 1592.80 20 14.68 2479 2 3
4 13 999.48 20 14.74 1737 2 5
5 13 442.76 20 14.84 990 2 5
6 13 148.16 20 14.91 578 2 3
7 8 0.08 165 14.91 354 2 9

Cycle 175 GMT 19/11/2023 23:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 31 14.88 488 2 3
2 7 2003.84 33 14.67 2979 2 4
3 13 1590.80 20 14.68 2497 2 3
4 13 1007.48 20 14.74 1748 2 5
5 13 423.48 20 14.84 961 2 3
6 13 138.08 20 14.92 553 2 4
7 8 0.16 165 14.92 339 2 8

Cycle 174 GMT 10/11/2023 1:26:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 31 14.88 481 2 3
2 7 2006.60 33 14.68 2969 2 3
3 13 1596.72 20 14.69 2484 2 4
4 13 1008.92 20 14.74 1745 2 4
5 13 440.08 20 14.84 990 2 4
6 13 149.16 20 14.91 581 2 3
7 8 0.20 165 14.91 350 2 8

Cycle 173 GMT 31/10/2023 3:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 31 14.88 480 2 3
2 7 2003.88 33 14.69 2975 2 3
3 13 1595.32 20 14.69 2492 2 3
4 13 997.96 20 14.74 1734 2 4
5 13 432.92 20 14.84 979 2 4
6 13 146.80 20 14.91 576 2 3
7 8 0.16 165 14.92 341 2 10

Cycle 172 GMT 21/10/2023 5:46: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 31 14.88 476 2 3
2 7 2003.88 33 14.68 2982 2 4
3 13 1584.52 20 14.69 2465 2 4
4 13 996.36 20 14.74 1732 2 6
5 13 534.44 20 14.81 1123 2 4
6 13 112.52 20 14.92 525 2 3
7 8 0.04 165 14.92 348 2 8

Cycle 171 GMT 11/10/2023 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 31 14.89 469 2 3
2 7 2005.00 33 14.67 2984 2 3
3 13 1596.72 20 14.69 2485 2 3
4 13 879.84 20 14.76 1583 2 4
5 13 450.40 20 14.84 997 2 4
6 13 81.40 20 14.94 477 2 3
7 8 -0.04 165 14.92 342 2 8

Cycle 170 GMT 1/10/2023 10: 3:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 14.89 479 2 3
2 7 2003.12 33 14.69 2967 2 3
3 13 1584.08 20 14.70 2474 2 4
4 13 1003.12 20 14.75 1742 2 6
5 13 440.12 20 14.84 991 2 4
6 13 154.44 20 14.91 578 2 3
7 8 0.04 165 14.92 340 2 8

Cycle 169 GMT 21/ 9/2023 12: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 31 14.88 482 2 3
2 7 2003.72 33 14.69 2970 2 3
3 13 1479.52 20 14.71 2346 2 4
4 13 918.52 20 14.76 1629 2 5
5 13 482.84 20 14.83 1047 2 4
6 13 95.60 20 14.93 492 2 3
7 8 0.08 165 14.92 345 2 10

Cycle 168 GMT 11/ 9/2023 14: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.44 31 14.89 513 2 3
2 7 2003.88 34 14.68 2960 2 3
3 13 1577.72 20 14.70 2465 2 3
4 13 877.52 20 14.77 1575 2 5
5 13 457.44 20 14.84 1013 2 4
6 13 86.20 20 14.94 489 2 3
7 8 0.04 165 14.92 346 2 6

Cycle 167 GMT 1/ 9/2023 16: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 31 14.89 471 2 3
2 7 2010.08 34 14.67 2976 2 4
3 13 1589.40 20 14.69 2481 2 5
4 13 979.00 20 14.75 1711 2 4
5 13 411.36 20 14.86 950 2 4
6 13 132.72 20 14.93 551 2 3
7 8 0.08 165 14.92 343 2 13

Cycle 166 GMT 22/ 8/2023 18:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 30 14.89 495 2 3
2 7 2005.08 33 14.69 2974 2 3
3 13 1594.12 20 14.69 2495 2 5
4 13 902.60 20 14.76 1607 2 5
5 13 469.68 20 14.83 1046 2 4
6 13 95.88 20 14.94 508 2 3
7 8 0.00 165 14.93 343 2 10

Cycle 165 GMT 12/ 8/2023 20:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 30 14.89 480 2 3
2 7 2003.40 33 14.69 2977 2 3
3 13 1583.80 20 14.69 2491 2 4
4 13 997.48 20 14.75 1739 2 4
5 13 419.84 20 14.85 963 2 4
6 13 133.88 20 14.93 565 2 4
7 8 0.12 165 14.92 356 2 9

Cycle 164 GMT 2/ 8/2023 22:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 30 14.88 498 2 3
2 7 2005.44 33 14.69 2975 2 3
3 13 1583.88 20 14.70 2498 2 3
4 13 1002.28 20 14.75 1753 2 5
5 13 424.16 20 14.85 983 2 4
6 13 131.36 20 14.92 572 2 3
7 8 0.04 165 14.92 355 2 8

Cycle 163 GMT 24/ 7/2023 0:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 14.88 492 2 3
2 7 2002.44 33 14.69 2973 2 4
3 13 1593.80 20 14.69 2495 2 3
4 13 1013.12 20 14.74 1760 2 5
5 13 557.60 20 14.82 1158 2 4
6 13 122.20 20 14.93 552 2 3
7 8 0.12 165 14.92 360 2 7

Cycle 162 GMT 14/ 7/2023 2:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 14.88 489 2 3
2 7 2002.28 33 14.69 2964 2 3
3 13 1593.36 20 14.69 2494 2 3
4 13 990.32 20 14.75 1723 2 5
5 13 535.48 20 14.83 1135 2 3
6 13 114.36 20 14.93 553 2 3
7 8 0.04 165 14.92 362 2 9

Cycle 161 GMT 4/ 7/2023 4:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 14.89 492 2 3
2 7 2005.76 33 14.69 2970 2 3
3 13 1467.04 20 14.72 2331 2 3
4 13 927.64 20 14.76 1652 2 6
5 13 481.00 20 14.84 1061 2 4
6 13 98.48 20 14.94 517 2 3
7 8 0.04 165 14.92 353 2 11

Cycle 160 GMT 24/ 6/2023 6:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.40 30 14.88 536 2 3
2 7 2008.04 33 14.68 2971 2 3
3 13 1575.48 20 14.70 2467 2 5
4 13 1006.88 20 14.75 1754 2 4
5 13 553.48 20 14.82 1144 2 4
6 13 124.28 20 14.93 555 2 3
7 8 0.00 165 14.93 355 2 11

Cycle 159 GMT 14/ 6/2023 8:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 30 14.89 494 2 3
2 7 2006.64 33 14.70 2975 2 4
3 13 1586.52 20 14.70 2484 2 3
4 13 1008.52 20 14.75 1757 2 6
5 13 418.08 20 14.86 979 2 4
6 13 72.88 20 14.96 461 2 3
7 8 0.08 165 14.93 353 2 8

Cycle 158 GMT 4/ 6/2023 10:56: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 14.89 495 2 3
2 7 2004.52 33 14.70 2970 2 3
3 13 1584.84 20 14.71 2471 2 3
4 13 992.92 20 14.76 1745 2 5
5 13 424.16 20 14.86 992 2 4
6 13 74.20 20 14.95 486 2 3
7 8 0.08 165 14.93 359 2 10

Cycle 157 GMT 25/ 5/2023 13: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 31 14.90 513 2 3
2 7 2004.64 33 14.70 2969 2 3
3 13 1583.60 20 14.71 2468 2 3
4 13 873.84 20 14.79 1571 2 5
5 13 445.80 20 14.86 995 2 5
6 13 80.08 20 14.96 476 2 3
7 8 0.12 165 14.93 356 2 10

Cycle 156 GMT 15/ 5/2023 15: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 31 14.89 508 2 3
2 7 2008.76 34 14.69 2977 2 4
3 13 1592.44 20 14.70 2493 2 3
4 13 995.64 20 14.76 1740 2 5
5 13 414.56 20 14.86 958 2 5
6 13 70.24 20 14.96 461 2 3
7 8 0.16 165 14.94 348 2 10

Cycle 155 GMT 5/ 5/2023 17:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 31 14.89 490 2 3
2 7 2003.52 33 14.70 2980 2 3
3 13 1726.32 20 14.68 2653 2 4
4 13 968.52 20 14.77 1701 2 4
5 13 409.60 20 14.87 946 2 4
6 13 123.00 20 14.94 540 2 3
7 8 0.04 165 14.94 352 2 11

Cycle 154 GMT 25/ 4/2023 19:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 31 14.89 533 2 3
2 7 2005.20 34 14.69 2973 2 4
3 13 1707.52 20 14.68 2646 2 4
4 13 953.64 20 14.77 1680 2 7
5 13 384.00 20 14.88 911 2 4
6 13 64.64 20 14.96 461 2 3
7 8 0.12 165 14.93 358 2 9

Cycle 153 GMT 15/ 4/2023 21:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 31 14.89 518 2 3
2 7 2003.88 33 14.70 2974 2 3
3 13 1465.60 20 14.72 2334 2 4
4 13 931.92 20 14.76 1677 2 5
5 13 482.64 20 14.85 1056 2 4
6 13 92.80 20 14.95 505 2 3
7 8 0.04 165 14.93 350 2 9

Cycle 152 GMT 5/ 4/2023 23:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 31 14.90 525 2 3
2 7 2007.24 33 14.69 2981 2 4
3 13 1611.12 20 14.70 2510 2 3
4 13 891.52 20 14.78 1598 2 5
5 13 469.56 20 14.85 1041 2 4
6 13 92.24 20 14.95 513 2 3
7 8 0.04 165 14.94 354 2 10

Cycle 151 GMT 27/ 3/2023 1:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 14.90 491 2 3
2 7 2003.92 33 14.70 2974 2 3
3 13 1459.32 20 14.73 2323 2 4
4 13 923.20 20 14.77 1659 2 4
5 13 491.68 20 14.85 1059 2 5
6 13 93.28 20 14.96 489 2 3
7 8 0.32 165 14.94 350 2 9

Cycle 150 GMT 17/ 3/2023 3:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 31 14.90 519 2 3
2 7 2003.80 33 14.70 2984 2 3
3 13 1576.44 20 14.71 2465 2 3
4 13 1002.28 20 14.77 1743 2 5
5 13 425.24 20 14.87 975 2 5
6 13 74.28 20 14.96 480 2 3
7 8 -0.04 165 14.94 356 2 12

Cycle 149 GMT 7/ 3/2023 5:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 31 14.90 507 2 3
2 7 2008.88 33 14.69 2985 2 3
3 13 1472.96 20 14.72 2349 2 4
4 13 912.20 20 14.78 1619 2 6
5 13 479.48 20 14.85 1046 2 4
6 13 88.64 20 14.95 502 2 3
7 8 0.00 165 14.94 359 2 8

Cycle 148 GMT 25/ 2/2023 7:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 14.90 491 2 3
2 7 2012.36 33 14.70 2993 2 3
3 13 1478.36 20 14.72 2339 2 4
4 13 1044.68 20 14.75 1796 2 6
5 13 458.12 20 14.86 1013 2 4
6 13 88.08 20 14.96 493 2 3
7 13 18.36 20 14.98 388 2 3
8 8 0.00 165 14.93 350 2 13
9 14 0.00 25 14.91 363 3 13

Cycle 147 GMT 15/ 2/2023 9: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 14.90 490 2 2
2 7 2003.64 33 14.70 2991 2 3
3 13 1598.84 20 14.71 2494 2 5
4 13 995.92 20 14.77 1738 2 5
5 13 429.92 20 14.87 982 2 5
6 13 138.52 20 14.94 578 2 3
7 8 0.00 165 14.94 345 2 10

Cycle 146 GMT 5/ 2/2023 11:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 14.91 486 2 3
2 7 2004.52 33 14.70 2996 2 3
3 13 1592.24 20 14.71 2480 2 3
4 13 1006.68 20 14.76 1753 2 4
5 13 433.16 20 14.87 1001 2 5
6 13 139.00 20 14.95 561 2 4
7 8 0.04 165 14.94 353 2 6

Cycle 145 GMT 26/ 1/2023 13:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 30 14.91 512 2 3
2 7 2007.52 33 14.70 2986 2 4
3 13 1581.08 20 14.71 2495 2 4
4 13 994.20 20 14.76 1745 2 5
5 13 435.80 20 14.87 988 2 6
6 13 147.68 20 14.95 577 2 4
7 8 0.08 165 14.94 357 2 7

Cycle 144 GMT 16/ 1/2023 15:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 30 14.91 499 2 3
2 7 2005.44 33 14.71 2973 2 4
3 13 1587.40 20 14.72 2488 2 5
4 13 993.32 20 14.77 1747 2 4
5 13 419.76 20 14.88 964 2 6
6 13 137.04 20 14.95 553 2 3
7 8 0.12 165 14.95 351 2 9

Cycle 143 GMT 6/ 1/2023 17:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.91 496 2 3
2 7 2003.40 33 14.70 2982 2 4
3 13 1599.96 20 14.72 2494 2 4
4 13 1003.88 20 14.77 1745 2 6
5 13 425.24 20 14.88 981 2 4
6 13 136.88 20 14.95 576 2 3
7 8 0.60 165 14.95 351 2 7
8 14 0.60 25 14.93 352 2 10

Cycle 142 GMT 27/12/2022 19:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.91 492 2 3
2 7 2004.92 34 14.70 2982 2 3
3 13 1580.48 20 14.71 2466 2 4
4 13 978.56 20 14.77 1704 2 6
5 13 400.80 20 14.89 935 2 4
6 13 121.40 20 14.96 538 2 3
7 8 0.00 165 14.95 352 2 11

Cycle 141 GMT 17/12/2022 21:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.91 502 2 3
2 7 2008.60 34 14.70 2973 2 4
3 13 1468.68 20 14.73 2329 2 5
4 13 1026.52 20 14.76 1776 2 6
5 13 418.48 20 14.88 962 2 3
6 13 127.80 20 14.95 552 2 3
7 8 -0.04 165 14.95 346 2 10

Cycle 140 GMT 8/12/2022 0: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.92 478 2 3
2 7 2002.52 33 14.71 2971 2 3
3 13 1459.12 20 14.74 2320 2 3
4 13 1027.84 20 14.76 1793 2 5
5 13 446.28 20 14.87 1010 2 4
6 13 85.00 20 14.97 474 2 3
7 8 0.00 165 14.96 352 2 10

Cycle 139 GMT 28/11/2022 2: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 14.91 479 2 3
2 7 2004.20 33 14.71 2981 2 3
3 13 1741.60 20 14.69 2678 2 3
4 13 979.16 20 14.78 1725 2 5
5 13 409.72 20 14.89 966 2 4
6 13 129.92 20 14.96 555 2 3
7 8 -0.08 165 14.95 350 2 8

Cycle 138 GMT 18/11/2022 4:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 30 14.92 491 2 3
2 7 2011.04 33 14.71 2996 2 3
3 13 1470.12 20 14.73 2350 2 4
4 13 926.76 20 14.78 1642 2 4
5 13 495.32 20 14.85 1063 2 5
6 13 102.08 20 14.97 515 2 3
7 8 0.12 165 14.95 350 2 9

Cycle 137 GMT 8/11/2022 6:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 30 14.92 493 2 3
2 7 2004.28 33 14.70 2981 2 3
3 13 1591.48 20 14.72 2502 2 3
4 13 1007.08 20 14.77 1758 2 5
5 13 433.64 20 14.88 984 2 5
6 13 139.68 20 14.96 571 2 3
7 8 -0.04 165 14.96 353 2 9

Cycle 136 GMT 29/10/2022 8:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 30 14.92 474 2 3
2 7 2008.40 34 14.70 2983 2 3
3 13 1579.40 20 14.71 2484 2 6
4 13 975.60 20 14.78 1712 2 4
5 13 407.84 20 14.89 956 2 3
6 13 75.96 20 14.98 496 2 3
7 8 0.08 165 14.96 352 2 10

Cycle 135 GMT 19/10/2022 10: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.93 481 2 3
2 7 2010.40 33 14.70 2990 2 3
3 13 1476.00 20 14.74 2346 2 4
4 13 1036.16 20 14.77 1783 2 5
5 13 437.60 20 14.88 988 2 5
6 13 88.08 20 14.98 492 2 3
7 8 0.08 165 14.96 349 2 10

Cycle 134 GMT 9/10/2022 12:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 30 14.92 488 2 2
2 7 2010.12 33 14.71 2994 2 4
3 13 1605.92 20 14.72 2499 2 3
4 13 1030.52 20 14.77 1780 2 5
5 13 442.64 20 14.88 1000 2 5
6 13 84.72 20 14.98 494 2 3
7 8 0.12 165 14.96 356 2 10

Cycle 133 GMT 29/ 9/2022 14:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.93 485 2 3
2 7 2010.88 34 14.70 2985 2 3
3 13 1475.96 20 14.74 2349 2 4
4 13 911.16 20 14.79 1625 2 5
5 13 464.12 20 14.87 1034 2 4
6 13 81.84 20 14.98 491 2 3
7 8 0.16 165 14.96 353 2 11

Cycle 132 GMT 19/ 9/2022 16: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 30 14.92 491 2 3
2 7 2004.80 33 14.71 2982 2 3
3 13 1468.44 20 14.74 2345 2 3
4 13 1054.68 20 14.76 1824 2 4
5 13 455.36 20 14.87 1029 2 4
6 13 86.76 20 14.98 507 2 3
7 8 0.00 165 14.96 355 2 11

Cycle 131 GMT 9/ 9/2022 18: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 14.93 483 2 3
2 7 2006.76 33 14.71 2982 2 4
3 13 1606.56 20 14.72 2511 2 4
4 13 1011.36 20 14.78 1755 2 4
5 13 436.32 20 14.89 997 2 4
6 13 84.64 20 14.98 490 2 3
7 8 0.00 165 14.96 354 2 9

Cycle 130 GMT 30/ 8/2022 20:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 30 14.93 500 2 3
2 7 2002.08 33 14.71 2984 2 3
3 13 1591.36 20 14.73 2489 2 3
4 13 1005.36 20 14.78 1743 2 4
5 13 418.00 20 14.90 966 2 4
6 13 127.72 20 14.97 554 2 3
7 8 0.08 165 14.97 352 2 10

Cycle 129 GMT 20/ 8/2022 22:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 14.93 499 2 3
2 7 2005.20 33 14.72 2977 2 3
3 13 1592.88 20 14.72 2494 2 3
4 13 1005.44 20 14.78 1753 2 5
5 13 417.32 20 14.90 975 2 4
6 13 138.44 20 14.96 586 2 3
7 8 0.08 165 14.97 357 2 7

Cycle 128 GMT 11/ 8/2022 0:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 30 14.93 490 2 3
2 7 2002.60 33 14.71 2988 2 3
3 13 1590.96 20 14.73 2476 2 5
4 13 995.28 20 14.78 1740 2 5
5 13 415.92 20 14.90 966 2 4
6 13 128.96 20 14.97 561 2 3
7 8 0.00 165 14.97 355 2 11

Cycle 127 GMT 1/ 8/2022 2:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 30 14.93 482 2 3
2 7 2008.88 33 14.72 2982 2 3
3 13 1585.36 20 14.73 2477 2 3
4 13 989.60 20 14.79 1723 2 5
5 13 410.08 20 14.90 952 2 4
6 13 129.40 20 14.97 550 2 4
7 8 0.08 165 14.97 354 2 8

Cycle 126 GMT 22/ 7/2022 4:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 30 14.93 493 2 3
2 7 2005.80 34 14.71 2982 2 3
3 13 1461.16 20 14.75 2330 2 4
4 13 1023.04 20 14.78 1777 2 4
5 13 421.04 20 14.90 979 2 5
6 13 70.76 20 14.99 482 2 3
7 8 0.08 165 14.97 356 2 9

Cycle 125 GMT 12/ 7/2022 6:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 14.93 486 2 3
2 7 2007.04 33 14.72 2990 2 3
3 13 1472.16 20 14.75 2336 2 3
4 13 919.44 20 14.80 1640 2 5
5 13 468.36 20 14.88 1055 2 4
6 13 90.88 20 14.99 500 2 3
7 8 0.00 165 14.96 358 2 8

Cycle 124 GMT 2/ 7/2022 8:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 30 14.93 492 2 2
2 7 2008.80 34 14.70 2985 2 3
3 13 1466.16 20 14.75 2351 2 5
4 13 1037.16 20 14.77 1798 2 4
5 13 436.00 20 14.89 991 2 6
6 13 86.40 20 14.99 504 2 3
7 8 0.00 165 14.97 357 2 9

Cycle 123 GMT 22/ 6/2022 10:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 30 14.93 502 2 2
2 7 2003.40 33 14.72 2995 2 3
3 13 1458.32 20 14.75 2332 2 6
4 13 883.72 20 14.81 1588 2 5
5 13 337.12 20 14.92 872 2 4
6 13 103.96 20 14.98 531 2 3
7 8 0.16 165 14.97 361 2 11

Cycle 122 GMT 12/ 6/2022 12:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 14.93 503 2 3
2 7 2004.48 33 14.72 2985 2 4
3 13 1584.64 20 14.74 2498 2 3
4 13 883.12 20 14.82 1603 2 6
5 13 459.12 20 14.89 1038 2 4
6 13 86.80 20 14.99 482 2 3
7 8 0.16 165 14.97 348 2 7

Cycle 121 GMT 2/ 6/2022 14:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 14.93 496 2 3
2 7 2005.96 33 14.71 2976 2 3
3 13 1572.40 20 14.73 2477 2 3
4 13 867.52 20 14.82 1585 2 4
5 13 430.80 20 14.90 1000 2 4
6 13 136.28 20 14.97 586 2 4
7 8 0.00 165 14.97 364 2 11

Cycle 120 GMT 23/ 5/2022 16:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 14.92 505 2 3
2 7 2004.80 33 14.72 2979 2 4
3 13 1469.28 20 14.75 2351 2 3
4 13 1041.84 20 14.78 1798 2 5
5 13 447.76 20 14.89 1021 2 6
6 13 93.40 20 14.99 500 2 3
7 8 0.08 165 14.98 353 2 8

Cycle 119 GMT 13/ 5/2022 18:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 14.93 494 2 2
2 7 2003.36 33 14.72 2975 2 3
3 13 1723.32 20 14.71 2668 2 3
4 13 964.24 20 14.81 1687 2 5
5 13 399.84 20 14.91 956 2 5
6 13 127.40 20 14.98 554 2 4
7 8 0.08 165 14.97 359 2 11

Cycle 118 GMT 3/ 5/2022 20:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 30 14.94 499 2 3
2 7 2003.16 33 14.73 2995 2 3
3 13 1478.24 20 14.75 2352 2 6
4 13 920.80 20 14.81 1647 2 7
5 13 364.60 20 14.92 901 2 4
6 13 112.88 20 14.99 529 2 3
7 8 -0.08 165 14.97 352 2 8

Cycle 117 GMT 23/ 4/2022 22:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.93 495 2 2
2 7 2002.64 33 14.72 2981 2 4
3 13 1452.08 20 14.76 2329 2 3
4 13 904.64 20 14.82 1621 2 7
5 13 348.72 20 14.93 869 2 4
6 13 102.12 20 15.00 522 2 3
7 8 0.20 165 14.98 363 2 9

Cycle 116 GMT 14/ 4/2022 0:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 14.93 502 2 2
2 7 2004.20 33 14.73 2992 2 3
3 13 1569.12 20 14.74 2467 2 5
4 13 986.44 20 14.81 1729 2 4
5 13 394.64 20 14.92 945 2 4
6 13 129.32 20 14.98 581 2 3
7 8 0.12 165 14.98 359 2 12

Cycle 115 GMT 4/ 4/2022 2:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 14.93 507 2 2
2 7 2006.40 34 14.72 3004 2 3
3 13 1468.28 20 14.75 2351 2 5
4 13 905.72 20 14.81 1645 2 4
5 13 340.36 20 14.93 860 2 4
6 13 100.36 20 14.99 534 2 4
7 8 0.12 165 14.97 368 2 12

Cycle 114 GMT 25/ 3/2022 4:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.93 502 2 2
2 7 2005.56 33 14.72 2984 2 3
3 13 1462.20 20 14.76 2334 2 4
4 13 908.32 20 14.82 1640 2 5
5 13 455.88 20 14.90 1020 2 4
6 13 80.56 20 15.00 490 2 4
7 8 0.00 165 14.98 367 2 8

Cycle 113 GMT 15/ 3/2022 6:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.76 30 14.93 530 2 2
2 7 2003.44 33 14.73 2978 2 3
3 13 1588.28 20 14.74 2499 2 5
4 13 988.04 20 14.81 1722 2 5
5 13 526.76 20 14.88 1126 2 4
6 13 106.24 20 14.99 535 2 3
7 8 0.20 165 14.98 366 2 11

Cycle 112 GMT 5/ 3/2022 8:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 14.94 506 2 2
2 7 2002.60 33 14.73 2993 2 4
3 13 1580.76 20 14.74 2480 2 4
4 13 987.52 20 14.81 1734 2 6
5 13 404.12 20 14.92 969 2 4
6 13 128.64 20 14.99 576 2 4
7 8 0.16 165 14.98 364 2 9

Cycle 111 GMT 23/ 2/2022 10:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 14.94 507 2 3
2 7 2002.92 33 14.73 2969 2 5
3 13 1444.48 20 14.77 2302 2 5
4 13 891.20 20 14.83 1598 2 7
5 13 448.20 20 14.91 1026 2 4
6 13 85.00 20 15.00 503 2 3
7 8 0.20 165 14.98 361 2 10

Cycle 110 GMT 13/ 2/2022 13: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 14.94 504 2 3
2 7 2005.04 33 14.73 2979 2 4
3 13 1602.52 20 14.74 2521 2 4
4 13 1002.08 20 14.81 1748 2 5
5 13 424.84 20 14.92 978 2 4
6 13 136.24 20 14.99 584 2 3
7 8 0.00 165 14.99 355 2 10

Cycle 109 GMT 3/ 2/2022 15: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 30 14.94 498 2 3
2 7 2008.72 33 14.73 2990 2 3
3 13 1589.72 20 14.74 2496 2 5
4 13 998.52 20 14.81 1738 2 5
5 13 410.40 20 14.92 963 2 4
6 13 126.08 20 14.99 567 2 4
7 8 0.16 165 14.98 362 2 11

Cycle 108 GMT 24/ 1/2022 17: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 14.95 483 2 2
2 7 2003.92 34 14.72 2987 2 4
3 13 1575.04 20 14.74 2484 2 4
4 13 991.08 20 14.81 1731 2 4
5 13 396.96 20 14.92 961 2 5
6 13 119.60 20 14.99 559 2 4
7 8 0.00 165 14.99 362 2 11

Cycle 107 GMT 14/ 1/2022 19:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 30 14.94 500 2 2
2 7 2005.76 34 14.73 2992 2 4
3 13 1464.60 20 14.77 2338 2 4
4 13 902.04 20 14.82 1637 2 5
5 13 457.44 20 14.91 1031 2 4
6 13 79.96 20 15.01 482 2 3
7 8 0.12 165 14.99 357 2 12

Cycle 106 GMT 4/ 1/2022 21:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 14.94 505 2 3
2 7 2006.64 33 14.73 2981 2 3
3 13 1588.36 20 14.74 2507 2 4
4 13 979.32 20 14.82 1724 2 5
5 13 405.48 20 14.92 952 2 3
6 13 123.44 20 14.99 563 2 3
7 8 0.16 165 14.99 363 2 10

Cycle 105 GMT 25/12/2021 23:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 30 14.95 499 2 3
2 7 2004.36 33 14.74 2993 2 3
3 13 1585.80 20 14.75 2498 2 5
4 13 988.84 20 14.81 1738 2 4
5 13 416.04 20 14.93 963 2 4
6 13 128.52 20 15.00 567 2 3
7 8 0.08 165 14.99 368 2 10

Cycle 104 GMT 16/12/2021 1:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 14.95 499 2 3
2 7 2004.72 34 14.73 2989 2 3
3 13 1450.64 20 14.77 2331 2 5
4 13 1001.16 20 14.81 1754 2 3
5 13 407.48 20 14.93 956 2 4
6 13 76.32 20 15.02 472 2 3
7 8 0.12 165 14.99 354 2 12

Cycle 103 GMT 6/12/2021 3:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 30 14.95 498 2 2
2 7 2007.92 33 14.74 2998 2 3
3 13 1582.36 20 14.75 2496 2 4
4 13 1003.20 20 14.81 1746 2 6
5 13 405.60 20 14.93 963 2 4
6 13 128.24 20 15.00 580 2 3
7 8 0.08 165 15.00 360 2 11

Cycle 102 GMT 26/11/2021 5:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 14.96 505 2 3
2 7 2006.84 33 14.73 2999 2 3
3 13 1588.72 20 14.74 2513 2 3
4 13 1000.40 20 14.81 1753 2 7
5 13 429.72 20 14.92 994 2 4
6 13 134.48 20 14.99 580 2 3
7 8 0.00 165 15.00 357 2 7

Cycle 101 GMT 16/11/2021 7:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 30 14.95 515 2 3
2 7 2004.08 33 14.74 2999 2 3
3 13 1588.16 20 14.74 2517 2 4
4 13 891.80 20 14.83 1620 2 7
5 13 452.84 20 14.92 1018 2 4
6 13 87.72 20 15.01 510 2 3
7 8 0.08 165 14.99 359 2 12

Cycle 100 GMT 6/11/2021 10: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 30 14.96 501 2 3
2 7 2002.88 33 14.74 2995 2 3
3 13 1460.08 20 14.77 2343 2 4
4 13 901.00 20 14.83 1626 2 5
5 13 466.80 20 14.91 1056 2 4
6 13 92.12 20 15.01 531 2 3
7 8 0.04 165 14.99 367 2 11

Cycle 99 GMT 27/10/2021 12: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 14.95 502 2 2
2 7 2002.04 33 14.74 2994 2 3
3 13 1577.28 19 14.75 2518 2 5
4 13 995.20 19 14.82 1741 2 4
5 13 552.36 19 14.89 1174 2 4
6 13 129.56 19 15.00 579 2 3
7 8 0.12 165 15.00 369 2 8

Cycle 98 GMT 17/10/2021 14: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 30 14.94 496 2 2
2 7 2003.12 33 14.74 2992 2 4
3 13 1592.20 19 14.75 2512 2 5
4 13 1011.32 19 14.81 1769 2 4
5 13 429.52 19 14.93 1002 2 5
6 13 148.80 19 15.00 606 2 3
7 13 16.32 19 15.03 412 2 3
8 8 -0.16 165 14.99 366 2 13

Cycle 97 GMT 7/10/2021 16:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 30 14.96 499 2 2
2 7 2005.32 33 14.74 2996 2 3
3 13 1598.04 19 14.75 2505 2 4
4 13 1014.80 19 14.81 1765 2 5
5 13 439.68 19 14.92 1004 2 4
6 13 147.68 19 15.00 608 2 4
7 13 33.84 19 15.02 434 2 3
8 8 0.00 165 14.99 365 2 12
9 14 0.00 25 14.97 362 2 12

Cycle 96 GMT 27/ 9/2021 18: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 30 14.96 483 2 3
2 7 2009.16 33 14.74 2996 2 3
3 13 1461.32 19 14.77 2348 2 4
4 13 911.00 19 14.83 1632 2 6
5 13 481.24 19 14.91 1068 2 4
6 13 105.24 19 15.01 537 2 3
7 8 0.08 165 15.00 359 2 9

Cycle 95 GMT 17/ 9/2021 20: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 30 14.97 491 2 3
2 7 2007.40 33 14.74 2990 2 4
3 13 1581.64 19 14.75 2508 2 4
4 13 995.52 19 14.82 1751 2 4
5 13 431.96 19 14.93 995 2 4
6 13 139.16 19 15.00 593 2 3
7 8 0.16 165 15.00 363 2 10

Cycle 94 GMT 7/ 9/2021 21:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 14.97 509 2 2
2 7 2004.20 33 14.74 2992 2 4
3 13 1465.20 19 14.78 2344 2 3
4 13 1038.40 19 14.81 1819 2 4
5 13 460.60 19 14.92 1042 2 5
6 13 101.96 19 15.02 534 2 4
7 8 0.08 165 15.01 358 2 9

Cycle 93 GMT 28/ 8/2021 23:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.97 487 2 3
2 7 2003.56 34 14.73 2993 2 3
3 13 1455.48 19 14.78 2337 2 4
4 13 895.84 19 14.85 1616 2 6
5 13 457.88 19 14.92 1044 2 4
6 13 94.76 19 15.02 521 2 4
7 8 0.00 165 15.01 358 2 8

Cycle 92 GMT 19/ 8/2021 1:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 30 14.97 499 2 2
2 7 2006.48 34 14.74 2983 2 3
3 13 1578.36 19 14.75 2493 2 4
4 13 985.88 19 14.83 1734 2 5
5 13 406.00 19 14.94 968 2 5
6 13 130.72 19 15.01 575 2 3
7 8 0.08 165 15.01 357 2 7

Cycle 91 GMT 9/ 8/2021 3:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 14.96 495 2 2
2 7 2003.40 33 14.74 2992 2 4
3 13 1466.60 19 14.78 2349 2 4
4 13 924.72 19 14.84 1651 2 5
5 13 484.96 19 14.92 1075 2 4
6 13 106.32 19 15.02 540 2 3
7 8 0.12 165 15.01 360 2 12

Cycle 90 GMT 30/ 7/2021 5:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 14.97 501 2 2
2 7 2008.40 31 14.76 3008 2 3
3 13 1588.32 18 14.77 2529 2 4
4 13 1026.36 18 14.83 1797 2 5
5 13 582.00 18 14.91 1207 2 4
6 13 153.56 18 15.01 618 2 4
7 13 37.52 18 15.04 439 2 3
8 8 -0.08 165 15.00 363 2 9

Cycle 89 GMT 20/ 7/2021 7:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.97 502 2 3
2 7 2007.12 32 14.76 3000 2 3
3 13 1586.92 18 14.78 2516 2 3
4 13 1027.92 18 14.83 1791 2 4
5 13 487.68 18 14.93 1077 2 4
6 13 132.12 18 15.02 568 2 3
7 13 34.96 18 15.04 432 2 3
8 8 0.04 165 15.01 359 2 8

Cycle 88 GMT 10/ 7/2021 9:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 30 14.98 490 2 3
2 7 2007.12 31 14.76 3000 2 3
3 13 1592.04 18 14.78 2530 2 3
4 13 1030.40 18 14.83 1800 2 5
5 13 607.32 18 14.90 1236 2 4
6 13 167.08 18 15.01 635 2 3
7 13 19.64 18 15.05 407 2 3
8 8 0.08 165 15.00 362 2 10

Cycle 87 GMT 30/ 6/2021 11:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.84 30 14.98 523 2 3
2 7 2003.68 31 14.77 2985 2 4
3 13 1603.68 18 14.78 2531 2 3
4 13 1046.32 18 14.83 1812 2 4
5 13 619.48 18 14.90 1258 2 4
6 13 181.88 18 15.01 666 2 4
7 13 22.76 18 15.05 419 2 3
8 8 0.00 165 15.01 364 2 12
9 14 0.00 25 14.99 356 3 11

Cycle 86 GMT 20/ 6/2021 13:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 14.96 508 2 2
2 7 2003.88 31 14.77 2988 2 3
3 13 1579.56 18 14.79 2507 2 3
4 13 1015.92 18 14.85 1775 2 5
5 13 593.04 18 14.91 1215 2 5
6 13 170.16 18 15.01 638 2 4
7 13 37.04 18 15.05 442 2 3
8 8 -0.04 165 15.01 365 2 13

Cycle 85 GMT 10/ 6/2021 15: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 14.98 517 2 2
2 7 2003.64 31 14.78 2979 2 3
3 13 1594.20 18 14.78 2520 2 4
4 13 1034.96 18 14.84 1811 2 4
5 13 600.68 18 14.91 1232 2 5
6 13 167.04 18 15.01 638 2 3
7 13 18.88 18 15.06 406 2 3
8 8 0.04 165 15.01 366 2 11

Cycle 84 GMT 31/ 5/2021 17: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.98 506 2 2
2 7 2007.56 31 14.78 2994 2 4
3 13 1603.64 18 14.78 2542 2 3
4 13 1173.92 18 14.81 1987 2 4
5 13 581.88 18 14.91 1207 2 5
6 13 162.92 18 15.02 631 2 4
7 8 0.04 165 15.03 360 2 9

Cycle 83 GMT 21/ 5/2021 18:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 14.99 504 2 2
2 7 2003.72 31 14.78 2997 2 3
3 13 1593.36 18 14.79 2512 2 4
4 13 1034.52 18 14.84 1815 2 5
5 13 600.24 18 14.91 1233 2 4
6 13 164.48 18 15.02 629 2 4
7 8 0.08 165 15.02 371 2 8

Cycle 82 GMT 11/ 5/2021 20:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.99 501 2 2
2 7 2002.32 31 14.77 2997 2 4
3 13 1584.72 18 14.79 2506 2 3
4 13 1019.88 18 14.84 1790 2 6
5 13 480.56 18 14.95 1068 2 4
6 13 123.12 18 15.04 554 2 3
7 8 0.00 165 15.03 367 2 11

Cycle 81 GMT 1/ 5/2021 22:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 29 14.99 492 2 2
2 7 2003.48 31 14.77 2997 2 4
3 13 1600.92 18 14.78 2523 2 4
4 13 1025.92 18 14.85 1798 2 3
5 13 477.88 18 14.95 1063 2 5
6 13 119.00 18 15.04 565 2 3
7 8 0.08 165 15.03 364 2 8

Cycle 80 GMT 22/ 4/2021 0:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 15.00 510 2 2
2 7 2005.48 31 14.78 2989 2 3
3 13 1485.52 18 14.81 2355 2 5
4 13 1079.80 18 14.84 1848 2 6
5 13 515.36 18 14.94 1116 2 4
6 13 133.92 18 15.04 580 2 3
7 8 0.12 165 15.04 364 2 10

Cycle 79 GMT 12/ 4/2021 2:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 15.00 495 2 2
2 7 2004.20 31 14.78 2982 2 3
3 13 1598.24 18 14.80 2522 2 3
4 13 1037.00 18 14.85 1810 2 4
5 13 600.68 18 14.92 1222 2 4
6 13 179.20 18 15.03 637 2 4
7 8 0.16 165 15.04 358 2 8

Cycle 78 GMT 2/ 4/2021 4: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 15.00 501 2 3
2 7 2005.60 31 14.78 3003 2 4
3 13 1468.76 18 14.81 2365 2 5
4 13 926.28 18 14.87 1657 2 4
5 13 514.36 18 14.95 1114 2 4
6 13 137.12 18 15.05 572 2 3
7 8 -0.04 165 15.04 357 2 9

Cycle 77 GMT 23/ 3/2021 5:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 30 15.01 511 2 3
2 7 2004.96 31 14.78 2979 2 3
3 13 1599.76 18 14.79 2516 2 4
4 13 1030.28 18 14.86 1771 2 4
5 13 601.96 18 14.92 1237 2 4
6 13 168.76 18 15.03 631 2 4
7 8 0.08 165 15.05 357 2 11

Cycle 76 GMT 13/ 3/2021 7:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 30 15.00 510 2 2
2 7 2006.20 31 14.78 2986 2 4
3 13 1573.36 18 14.80 2500 2 4
4 13 1031.36 18 14.86 1796 2 4
5 13 588.64 18 14.93 1211 2 4
6 13 158.56 18 15.05 613 2 3
7 8 0.04 165 15.05 359 2 7

Cycle 75 GMT 3/ 3/2021 9:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 29 15.00 517 2 2
2 7 2006.32 31 14.78 3000 2 2
3 13 1483.56 18 14.81 2372 2 4
4 13 1068.12 18 14.84 1855 2 4
5 13 502.64 18 14.96 1089 2 4
6 13 129.40 18 15.06 564 2 3
7 8 0.08 165 15.05 362 2 9
8 14 0.08 25 15.03 366 2 10

Cycle 74 GMT 21/ 2/2021 11:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 15.01 515 2 2
2 7 2007.64 32 14.78 2999 2 3
3 13 1594.60 18 14.80 2515 2 5
4 13 1156.04 18 14.83 1970 2 5
5 13 551.36 18 14.95 1164 2 4
6 13 144.24 18 15.06 599 2 3
7 13 33.56 18 15.08 425 2 3
8 8 0.24 165 15.05 364 2 10

Cycle 73 GMT 11/ 2/2021 13: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 29 15.02 499 2 2
2 7 2003.44 31 14.80 2996 2 3
3 13 1735.80 18 14.78 2689 2 4
4 13 1028.28 18 14.86 1800 2 5
5 13 602.44 18 14.94 1230 2 4
6 13 170.72 18 15.05 630 2 3
7 8 0.16 165 15.06 365 2 8

Cycle 72 GMT 1/ 2/2021 15: 5: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 29 15.03 489 2 2
2 7 2003.40 31 14.80 2987 2 4
3 13 1729.44 18 14.78 2703 2 4
4 13 1134.40 18 14.85 1929 2 3
5 13 563.64 18 14.96 1173 2 4
6 13 159.64 18 15.06 617 2 4
7 8 0.00 165 15.06 365 2 9

Cycle 71 GMT 22/ 1/2021 16:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 29 15.02 518 2 2
2 7 2003.72 31 14.79 2979 2 4
3 13 1588.80 18 14.80 2524 2 4
4 13 1020.56 18 14.87 1793 2 4
5 13 574.84 18 14.95 1204 2 4
6 13 149.80 18 15.06 601 2 3
7 8 0.12 165 15.07 358 2 10

Cycle 70 GMT 12/ 1/2021 18:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 29 15.03 494 2 2
2 7 2007.44 31 14.79 3006 2 3
3 13 1603.56 18 14.80 2541 2 3
4 13 1029.96 18 14.87 1799 2 4
5 13 596.16 18 14.95 1224 2 5
6 13 157.08 18 15.06 621 2 3
7 8 0.12 165 15.07 360 2 9

Cycle 69 GMT 2/ 1/2021 20:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.04 29 15.04 528 2 3
2 7 2005.04 31 14.80 2987 2 4
3 13 1603.20 18 14.80 2532 2 3
4 13 1050.24 18 14.86 1825 2 6
5 13 485.88 18 14.98 1078 2 4
6 13 200.84 18 15.05 677 2 3
7 8 0.16 165 15.07 363 2 8

Cycle 68 GMT 23/12/2020 22:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 29 15.04 502 2 2
2 7 2006.92 31 14.81 2998 2 3
3 13 1736.36 18 14.79 2705 2 5
4 13 1133.44 18 14.85 1938 2 4
5 13 560.64 18 14.97 1174 2 5
6 13 146.24 18 15.08 601 2 3
7 8 0.08 165 15.08 362 2 9

Cycle 67 GMT 14/12/2020 0:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.04 496 2 3
2 7 2006.44 31 14.81 3000 2 3
3 13 1597.76 18 14.81 2532 2 5
4 13 1031.76 18 14.88 1798 2 6
5 13 591.16 18 14.96 1234 2 4
6 13 158.00 18 15.07 626 2 4
7 8 0.08 165 15.08 367 2 10

Cycle 66 GMT 4/12/2020 2:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 29 15.04 498 2 2
2 7 2004.40 31 14.81 2988 2 3
3 13 1578.92 18 14.81 2503 2 3
4 13 1021.68 18 14.89 1779 2 5
5 13 579.72 18 14.97 1203 2 4
6 13 164.56 18 15.08 623 2 3
7 8 0.08 165 15.09 362 2 11

Cycle 65 GMT 24/11/2020 4:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 15.04 501 2 2
2 7 2003.28 31 14.80 3006 2 3
3 13 1582.40 18 14.82 2524 2 4
4 13 1025.76 18 14.89 1798 2 5
5 13 472.68 18 15.00 1073 2 4
6 13 188.36 18 15.07 668 2 4
7 8 -0.08 165 15.09 362 2 7

Cycle 64 GMT 14/11/2020 6:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 29 15.06 499 2 2
2 7 2002.48 31 14.81 2988 2 3
3 13 1583.92 18 14.82 2507 2 5
4 13 1019.60 18 14.89 1795 2 5
5 13 590.92 18 14.97 1213 2 4
6 13 160.36 18 15.09 632 2 3
7 13 38.36 18 15.11 436 2 3
8 8 0.08 165 15.08 364 2 9

Cycle 63 GMT 4/11/2020 8:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 15.07 489 2 3
2 7 2003.40 31 14.81 2989 2 4
3 13 1722.44 18 14.80 2681 2 3
4 13 1126.40 18 14.87 1925 2 5
5 13 558.04 18 14.99 1179 2 4
6 13 143.88 18 15.10 590 2 3
7 8 0.12 165 15.10 356 2 11

Cycle 62 GMT 25/10/2020 10: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 15.07 495 2 3
2 7 2003.00 31 14.81 2989 2 3
3 13 1475.00 18 14.85 2355 2 3
4 13 1066.20 18 14.89 1829 2 3
5 13 490.96 18 15.01 1071 2 4
6 13 119.52 18 15.11 554 2 3
7 8 0.08 165 15.10 357 2 7

Cycle 61 GMT 15/10/2020 11:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 15.07 487 2 3
2 7 2003.64 31 14.81 2995 2 4
3 13 1587.04 18 14.83 2498 2 5
4 13 1036.28 18 14.90 1808 2 6
5 13 603.92 18 14.98 1240 2 4
6 13 167.84 18 15.10 622 2 3
7 8 0.04 165 15.10 359 2 11

Cycle 60 GMT 5/10/2020 13:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 29 15.07 487 2 3
2 7 2008.28 30 14.82 3001 2 3
3 13 1596.64 17 14.83 2514 2 3
4 13 1164.28 17 14.88 1964 2 5
5 13 601.36 17 14.99 1234 2 4
6 13 196.88 17 15.09 677 2 3
7 13 21.24 17 15.14 406 2 3
8 8 -0.04 165 15.11 353 2 9

Cycle 59 GMT 25/ 9/2020 15:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 29 15.07 511 2 3
2 7 2003.00 30 14.82 2999 2 3
3 13 1600.40 17 14.83 2518 2 5
4 13 1041.40 17 14.91 1803 2 5
5 13 620.52 17 14.99 1248 2 4
6 13 199.52 17 15.10 675 2 3
7 13 21.56 17 15.14 418 2 3
8 8 0.08 165 15.11 361 2 11

Cycle 58 GMT 15/ 9/2020 17:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 29 15.08 490 2 3
2 7 2005.28 30 14.83 2998 2 3
3 13 1742.72 17 14.81 2702 2 6
4 13 1158.68 17 14.88 1957 2 5
5 13 722.92 17 14.96 1398 2 5
6 13 273.44 17 15.07 782 2 4
7 13 29.80 17 15.14 427 2 3
8 8 0.04 165 15.11 360 2 9

Cycle 57 GMT 5/ 9/2020 19: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 29 15.08 481 2 3
2 7 2003.84 31 14.83 3002 2 3
3 13 1717.48 17 14.82 2668 2 3
4 13 1130.76 17 14.89 1924 2 3
5 13 580.04 17 15.00 1200 2 4
6 13 175.84 17 15.11 641 2 4
7 13 37.64 17 15.14 436 2 3
8 8 0.08 165 15.11 362 2 10

Cycle 56 GMT 26/ 8/2020 20:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 29 15.09 502 2 3
2 7 2002.36 30 14.84 2992 2 3
3 13 1596.80 17 14.83 2535 2 5
4 13 1049.76 17 14.91 1824 2 4
5 13 629.04 17 14.99 1268 2 4
6 13 213.44 17 15.10 698 2 4
7 13 23.24 17 15.15 418 2 3
8 8 0.12 165 15.12 358 2 10

Cycle 55 GMT 16/ 8/2020 22:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 15.09 481 2 3
2 7 2003.48 30 14.84 2983 2 3
3 13 1595.28 17 14.85 2524 2 3
4 13 1172.08 17 14.89 1981 2 5
5 13 728.04 17 14.97 1408 2 4
6 13 278.88 17 15.08 799 2 4
7 13 28.16 17 15.15 413 2 3
8 8 -0.04 165 15.12 357 2 12

Cycle 54 GMT 7/ 8/2020 0:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 29 15.08 495 2 3
2 7 2003.92 30 14.85 2986 2 3
3 13 1586.80 17 14.85 2511 2 4
4 13 1035.36 17 14.93 1801 2 6
5 13 617.56 17 15.00 1262 2 4
6 13 198.36 17 15.11 680 2 4
7 13 20.52 17 15.16 412 2 3
8 8 0.08 165 15.12 367 2 10

Cycle 53 GMT 28/ 7/2020 2:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.20 29 15.09 516 2 3
2 7 2002.64 30 14.84 3007 2 3
3 13 1584.64 17 14.85 2520 2 4
4 13 1155.40 17 14.90 1966 2 6
5 13 704.48 17 14.98 1376 2 5
6 13 254.36 17 15.09 767 2 4
7 13 28.48 17 15.16 425 2 3
8 8 0.00 165 15.12 360 2 8

Cycle 52 GMT 18/ 7/2020 4:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 29 15.10 519 2 3
2 7 2004.16 30 14.84 2997 2 4
3 13 1591.08 17 14.85 2520 2 4
4 13 1051.88 17 14.93 1832 2 6
5 13 624.80 17 15.00 1282 2 4
6 13 203.72 17 15.11 692 2 4
7 13 20.12 17 15.16 415 2 3
8 8 0.08 165 15.13 368 2 13

Cycle 51 GMT 8/ 7/2020 6:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 15.10 512 2 3
2 7 2001.84 30 14.85 3004 2 3
3 13 1597.80 17 14.85 2534 2 5
4 13 1163.52 17 14.90 1978 2 4
5 13 605.68 17 15.01 1246 2 4
6 13 201.36 17 15.12 683 2 4
7 8 0.12 165 15.14 357 2 10
8 14 0.12 25 15.12 367 3 8

Cycle 50 GMT 28/ 6/2020 7:52: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 29 15.11 512 2 3
2 7 2009.16 31 14.83 3007 2 4
3 13 1605.40 17 14.85 2539 2 4
4 13 1169.20 17 14.90 1994 2 4
5 13 714.60 17 14.98 1392 2 4
6 13 261.40 17 15.10 769 2 4
7 8 0.04 165 15.14 361 2 9

Cycle 49 GMT 18/ 6/2020 9:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 29 15.10 505 2 2
2 7 2004.96 30 14.85 2999 2 4
3 13 1613.52 17 14.85 2562 2 4
4 13 1048.00 17 14.93 1830 2 4
5 13 619.72 17 15.01 1267 2 4
6 13 203.08 17 15.12 688 2 4
7 8 0.16 165 15.15 359 2 9

Cycle 48 GMT 8/ 6/2020 11:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 15.11 517 2 3
2 7 2003.80 30 14.84 2998 2 4
3 13 1589.36 17 14.86 2501 2 3
4 13 1050.32 17 14.93 1849 2 5
5 13 628.16 17 15.02 1273 2 4
6 13 196.28 17 15.13 671 2 4
7 8 0.16 165 15.14 365 2 6

Cycle 47 GMT 29/ 5/2020 13: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 29 15.10 512 2 3
2 7 2007.00 30 14.84 3003 2 4
3 13 1602.72 17 14.86 2525 2 4
4 13 1036.28 17 14.94 1832 2 5
5 13 608.32 17 15.02 1260 2 4
6 13 182.80 17 15.13 666 2 4
7 8 -0.04 165 15.14 371 2 9

Cycle 46 GMT 19/ 5/2020 14:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 29 15.11 516 2 3
2 7 2003.92 30 14.84 2986 2 3
3 13 1594.48 17 14.86 2536 2 3
4 13 1039.12 17 14.94 1810 2 4
5 13 606.96 17 15.02 1250 2 4
6 13 185.84 17 15.14 651 2 3
7 8 0.12 165 15.15 371 2 9

Cycle 45 GMT 9/ 5/2020 16:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 29 15.11 526 2 3
2 7 2002.48 30 14.85 3003 2 4
3 13 1580.52 17 14.86 2524 2 3
4 13 1041.32 17 14.94 1827 2 6
5 13 618.00 17 15.03 1269 2 4
6 13 198.16 17 15.13 678 2 4
7 8 0.12 165 15.15 361 2 9

Cycle 44 GMT 29/ 4/2020 18:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 29 15.11 538 2 3
2 7 2003.80 30 14.86 2976 2 3
3 13 1594.44 17 14.86 2517 2 4
4 13 1039.16 17 14.95 1799 2 5
5 13 599.80 17 15.03 1242 2 5
6 13 184.68 17 15.14 662 2 4
7 8 0.12 165 15.15 370 2 11

Cycle 43 GMT 19/ 4/2020 20: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 29 15.12 516 2 3
2 7 2004.04 30 14.85 2981 2 4
3 13 1608.16 17 14.87 2551 2 3
4 13 1186.16 17 14.92 2002 2 4
5 13 612.76 17 15.04 1239 2 4
6 13 197.32 17 15.14 687 2 4
7 8 0.08 165 15.16 375 2 10

Cycle 42 GMT 9/ 4/2020 21:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 29 15.12 521 2 3
2 7 2003.40 30 14.85 2993 2 3
3 13 1605.32 17 14.86 2541 2 3
4 13 1058.12 17 14.95 1852 2 5
5 13 636.72 17 15.03 1290 2 5
6 13 209.00 17 15.13 701 2 4
7 8 0.04 165 15.16 367 2 9

Cycle 41 GMT 30/ 3/2020 23:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 29 15.12 518 2 3
2 7 2008.12 30 14.87 2996 2 4
3 13 1606.56 17 14.87 2548 2 4
4 13 1060.76 17 14.95 1844 2 4
5 13 636.00 17 15.03 1287 2 4
6 13 213.92 17 15.14 705 2 4
7 8 0.16 165 15.16 363 2 11

Cycle 40 GMT 21/ 3/2020 0:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 15.13 540 2 2
2 7 2003.20 30 14.87 3000 2 3
3 13 1577.88 17 14.88 2509 2 4
4 13 1026.40 17 14.97 1793 2 5
5 13 506.36 17 15.08 1091 2 4
6 13 227.96 17 15.14 722 2 4
7 8 -0.08 165 15.16 365 2 9

Cycle 39 GMT 11/ 3/2020 2:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 29 15.12 533 2 3
2 7 2002.16 30 14.87 3001 2 3
3 13 1738.56 17 14.86 2718 2 3
4 13 1141.88 17 14.94 1955 2 4
5 13 578.72 17 15.06 1208 2 5
6 13 176.88 17 15.16 652 2 3
7 8 -0.08 165 15.17 368 2 9

Cycle 38 GMT 1/ 3/2020 4:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 29 15.13 535 2 2
2 7 2002.32 31 14.87 3003 2 4
3 13 1573.08 17 14.88 2508 2 5
4 13 1142.16 17 14.94 1957 2 6
5 13 568.36 17 15.06 1202 2 4
6 13 285.24 17 15.12 808 2 4
7 8 0.16 165 15.17 364 2 8

Cycle 37 GMT 20/ 2/2020 6: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 29 15.13 517 2 2
2 7 2006.48 30 14.88 3004 2 3
3 13 1600.64 17 14.88 2541 2 3
4 13 1157.64 17 14.94 1974 2 4
5 13 586.08 17 15.06 1227 2 4
6 13 185.44 17 15.16 665 2 4
7 8 0.00 165 15.18 367 2 9

Cycle 36 GMT 10/ 2/2020 7:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 15.13 522 2 3
2 7 2007.84 30 14.88 2998 2 3
3 13 1604.64 17 14.88 2557 2 5
4 13 1175.44 17 14.94 2000 2 5
5 13 596.00 17 15.06 1235 2 5
6 13 192.76 17 15.16 672 2 3
7 13 22.32 17 15.21 419 2 3
8 8 0.08 165 15.17 368 2 10

Cycle 35 GMT 31/ 1/2020 9:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 29 15.14 526 2 3
2 7 2005.28 30 14.87 3003 2 4
3 13 1463.00 17 14.92 2350 2 4
4 13 1181.44 17 14.94 1987 2 5
5 13 583.88 17 15.07 1218 2 4
6 13 170.56 17 15.17 647 2 3
7 8 0.12 165 15.18 373 2 9

Cycle 34 GMT 21/ 1/2020 11:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 29 15.15 519 2 3
2 7 2004.12 30 14.87 3025 2 3
3 13 1598.84 17 14.88 2554 2 5
4 13 1170.08 17 14.94 1985 2 5
5 13 579.24 17 15.07 1217 2 4
6 13 176.92 17 15.17 657 2 4
7 8 -0.04 165 15.18 366 2 9

Cycle 33 GMT 11/ 1/2020 13:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 15.15 504 2 3
2 7 2001.04 31 14.88 3006 2 3
3 13 1577.56 17 14.90 2509 2 4
4 13 1148.08 17 14.96 1950 2 4
5 13 566.52 17 15.08 1197 2 5
6 13 172.44 17 15.18 646 2 4
7 8 0.04 165 15.19 364 2 9

Cycle 32 GMT 1/ 1/2020 15: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 29 15.15 498 2 2
2 7 2007.64 30 14.88 2992 2 4
3 13 1736.80 17 14.87 2713 2 3
4 13 1015.52 17 14.99 1803 2 5
5 13 605.48 17 15.07 1251 2 4
6 13 194.08 17 15.17 683 2 3
7 13 50.72 17 15.21 465 2 3
8 8 0.16 165 15.18 368 2 9

Cycle 31 GMT 22/12/2019 16:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 29 15.15 532 2 3
2 7 2002.28 30 14.89 3011 2 3
3 13 1602.32 17 14.90 2551 2 4
4 13 1046.28 17 14.99 1838 2 4
5 13 631.68 17 15.06 1288 2 4
6 13 204.88 17 15.17 702 2 4
7 8 0.12 165 15.19 367 2 12

Cycle 30 GMT 12/12/2019 18: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 29 15.15 534 2 3
2 7 2008.00 31 14.88 3013 2 4
3 13 1478.00 17 14.92 2396 2 5
4 13 1056.68 17 14.98 1858 2 5
5 13 503.08 17 15.10 1120 2 4
6 13 223.24 17 15.16 733 2 3
7 8 0.24 165 15.19 372 2 9

Cycle 29 GMT 2/12/2019 19:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 29 15.16 518 2 3
2 7 2005.64 30 14.88 3018 2 3
3 13 1581.00 17 14.91 2534 2 3
4 13 1010.16 17 15.00 1796 2 6
5 13 582.96 17 15.08 1221 2 4
6 13 167.12 17 15.19 651 2 3
7 8 -0.04 165 15.20 373 2 9

Cycle 28 GMT 22/11/2019 21:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 15.16 498 2 3
2 7 2003.20 30 14.90 3012 2 3
3 13 1732.48 17 14.88 2718 2 5
4 13 1027.96 17 14.99 1825 2 4
5 13 611.80 17 15.07 1269 2 4
6 13 199.24 17 15.18 690 2 3
7 8 0.16 165 15.20 371 2 12

Cycle 27 GMT 12/11/2019 23: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.44 28 15.17 534 2 3
2 7 2007.20 30 14.89 3008 2 4
3 13 1595.28 17 14.91 2540 2 4
4 13 1036.36 17 15.00 1821 2 4
5 13 605.00 17 15.08 1255 2 4
6 13 176.80 17 15.19 657 2 4
7 8 0.04 165 15.20 369 2 10

Cycle 26 GMT 3/11/2019 0:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 28 15.17 520 2 3
2 7 2006.36 30 14.89 3023 2 3
3 13 1597.84 17 14.91 2541 2 3
4 13 1032.40 17 15.00 1821 2 5
5 13 501.12 17 15.11 1110 2 5
6 13 221.16 17 15.18 727 2 4
7 8 0.08 165 15.21 370 2 11

Cycle 25 GMT 24/10/2019 2:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 28 15.17 512 2 3
2 7 2007.60 30 14.90 2983 2 3
3 13 1574.44 17 14.92 2515 2 5
4 13 1011.08 17 15.02 1770 2 6
5 13 586.24 17 15.09 1224 2 4
6 13 174.04 17 15.20 650 2 3
7 8 0.16 165 15.21 369 2 7

Cycle 24 GMT 14/10/2019 4: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 28 15.17 522 2 3
2 7 2002.04 30 14.91 3005 2 4
3 13 1605.28 17 14.92 2547 2 6
4 13 1166.36 17 14.98 1984 2 7
5 13 593.48 17 15.10 1236 2 4
6 13 188.32 17 15.19 678 2 4
7 13 41.48 17 15.24 452 2 3
8 8 -0.04 165 15.20 372 2 9

Cycle 23 GMT 4/10/2019 5:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 28 15.18 492 2 3
2 7 2003.36 30 14.90 2988 2 4
3 13 1600.04 17 14.92 2549 2 3
4 13 1033.60 17 15.01 1813 2 4
5 13 605.52 17 15.09 1257 2 4
6 13 187.24 17 15.20 676 2 4
7 13 39.44 17 15.24 452 2 3
8 8 0.08 165 15.20 372 2 10

Cycle 22 GMT 24/ 9/2019 7: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 15.17 498 2 3
2 7 2004.12 30 14.90 3010 2 4
3 13 1593.04 17 14.92 2554 2 5
4 13 1151.56 17 14.98 1970 2 5
5 13 576.48 17 15.10 1204 2 5
6 13 165.08 17 15.21 640 2 4
7 13 33.84 17 15.24 443 2 3
8 8 0.16 165 15.21 373 2 12

Cycle 21 GMT 14/ 9/2019 8:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 28 15.18 527 2 3
2 7 2010.68 30 14.90 3006 2 3
3 13 1486.36 16 14.96 2411 2 4
4 13 1074.68 16 15.02 1871 2 6
5 13 641.48 16 15.09 1306 2 4
6 13 224.00 16 15.20 732 2 4
7 13 25.76 16 15.25 437 2 3
8 8 0.08 165 15.21 382 2 12

Cycle 20 GMT 4/ 9/2019 10: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 28 15.18 524 2 3
2 7 2003.08 30 14.91 2990 2 3
3 13 1601.04 16 14.94 2540 2 3
4 13 1159.96 16 15.00 1983 2 4
5 13 590.84 16 15.11 1244 2 4
6 13 202.20 16 15.21 701 2 4
7 13 25.52 16 15.25 441 2 3
8 8 0.08 165 15.22 383 2 11

Cycle 19 GMT 25/ 8/2019 11:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 28 15.18 523 2 2
2 7 2003.68 30 14.92 2994 2 3
3 13 1598.92 16 14.94 2552 2 3
4 13 1036.80 16 15.03 1832 2 6
5 13 615.20 16 15.11 1255 2 5
6 13 206.40 16 15.21 717 2 3
7 13 22.84 16 15.25 432 2 3
8 8 -0.04 165 15.22 385 2 10

Cycle 18 GMT 15/ 8/2019 12:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 28 15.19 518 2 3
2 7 2002.80 30 14.92 2992 2 3
3 13 1591.36 16 14.95 2540 2 5
4 13 1152.56 16 15.00 1995 2 4
5 13 581.20 16 15.12 1230 2 4
6 13 190.84 16 15.22 686 2 4
7 13 40.92 16 15.25 463 2 3
8 8 0.04 165 15.22 389 2 11

Cycle 17 GMT 5/ 8/2019 14:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 28 15.18 539 2 3
2 7 2006.88 30 14.93 3016 2 3
3 13 1603.40 16 14.95 2579 2 3
4 13 1056.12 16 15.03 1859 2 4
5 13 649.24 16 15.10 1328 2 5
6 13 236.32 16 15.20 761 2 3
7 13 23.84 16 15.26 441 2 3
8 8 0.08 165 15.22 393 2 11

Cycle 16 GMT 26/ 7/2019 15:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 28 15.19 565 2 3
2 7 2007.00 30 14.92 3017 2 3
3 13 1594.68 16 14.95 2576 2 4
4 13 1027.52 16 15.04 1821 2 4
5 13 617.20 16 15.12 1277 2 5
6 13 206.20 16 15.22 718 2 3
7 13 21.08 16 15.26 437 2 3
8 8 0.00 165 15.23 388 2 11

Cycle 15 GMT 16/ 7/2019 17: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 28 15.19 553 2 3
2 7 2004.48 30 14.93 3004 2 5
3 13 1592.00 16 14.96 2553 2 4
4 13 1149.44 16 15.01 1986 2 6
5 13 589.56 16 15.13 1251 2 5
6 13 189.00 16 15.22 692 2 4
7 8 0.08 165 15.23 402 2 12

Cycle 14 GMT 6/ 7/2019 18:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 28 15.20 541 2 3
2 7 2005.80 31 14.93 3004 2 4
3 13 1579.56 16 14.97 2524 2 4
4 13 1040.20 16 15.04 1844 2 6
5 13 613.68 16 15.12 1280 2 4
6 13 205.92 16 15.22 719 2 4
7 8 0.08 165 15.23 413 2 10

Cycle 13 GMT 26/ 6/2019 20:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 15.21 565 2 3
2 7 2004.16 31 14.92 3032 2 3
3 13 1593.72 16 14.96 2568 2 5
4 13 1042.76 16 15.04 1854 2 6
5 13 620.32 16 15.12 1303 2 4
6 13 209.12 16 15.22 733 2 4
7 8 0.04 165 15.24 401 2 6

Cycle 12 GMT 16/ 6/2019 21:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 15.22 475 2 3
2 7 2003.64 30 14.95 2963 2 3
3 13 1584.96 16 14.99 2480 2 5
4 13 1015.28 16 15.07 1742 2 4
5 13 584.72 16 15.15 1172 2 4
6 13 295.64 16 15.21 779 2 3
7 8 0.08 165 15.27 326 2 10

Cycle 11 GMT 6/ 6/2019 23: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.12 28 15.23 491 2 3
2 7 2007.04 30 14.95 2969 2 3
3 13 1590.92 16 14.99 2490 2 4
4 13 1028.16 16 15.07 1762 2 6
5 13 609.72 16 15.14 1211 2 5
6 13 202.08 16 15.25 643 2 3
7 8 0.08 165 15.27 326 2 7
8 14 0.08 75 15.24 321 2 15

Cycle 10 GMT 28/ 5/2019 0: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 27 15.23 496 2 3
2 7 2003.00 30 14.95 2960 2 3
3 13 1583.96 16 14.99 2487 2 4
4 13 1020.84 16 15.08 1757 2 5
5 13 607.60 16 15.15 1204 2 5
6 13 198.68 16 15.25 641 2 4
7 8 0.16 165 15.27 329 2 10

Cycle 9 GMT 18/ 5/2019 1:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 27 15.24 483 2 3
2 7 2002.36 30 14.96 2962 2 3
3 13 1587.64 16 15.00 2483 2 4
4 13 1033.52 16 15.08 1773 2 4
5 13 631.48 16 15.15 1239 2 4
6 13 217.44 16 15.25 673 2 4
7 8 0.04 165 15.27 339 2 10

Cycle 8 GMT 8/ 5/2019 3: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 27 15.23 477 2 2
2 7 2002.12 30 14.97 2963 2 4
3 13 1584.72 16 15.00 2478 2 4
4 13 926.76 16 15.10 1633 2 4
5 13 545.32 16 15.17 1123 2 4
6 13 262.16 16 15.23 730 2 4
7 8 0.16 165 15.27 327 2 9

Cycle 7 GMT 28/ 4/2019 4:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 27 15.24 484 2 3
2 7 2003.04 30 14.97 2970 2 4
3 13 1587.44 16 15.00 2476 2 4
4 13 1025.12 16 15.08 1755 2 4
5 13 606.48 16 15.16 1207 2 4
6 13 201.40 16 15.25 645 2 4
7 8 -0.12 165 15.27 328 2 8

Cycle 6 GMT 18/ 4/2019 5:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 26 15.25 479 2 3
2 10 1033.84 2 15.18 1817 2 3
3 7 2002.72 38 14.92 2950 2 5
4 13 1380.64 18 15.02 2207 2 5
5 13 785.88 18 15.12 1442 2 5
6 13 336.00 18 15.22 839 2 4
7 8 0.00 165 15.28 332 2 8

Cycle 5 GMT 8/ 4/2019 7:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 23 15.25 477 2 3
2 10 1024.32 3 15.18 1787 2 4
3 3 1019.72 1 15.27 1796 2 4
4 7 2003.20 38 14.92 2955 2 3
5 13 1264.20 18 15.05 2062 2 4
6 13 707.04 18 15.15 1335 2 5
7 13 283.08 18 15.24 764 2 5
8 8 0.04 165 15.28 335 2 6

Cycle 4 GMT 29/ 3/2019 8:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 26 15.24 489 2 3
2 7 1519.80 38 15.06 2333 2 3
3 13 1124.56 18 15.10 1866 2 6
4 13 674.60 18 15.17 1286 2 4
5 13 234.00 18 15.26 691 2 4
6 8 0.16 165 15.29 328 2 13

Cycle 3 GMT 28/ 3/2019 8:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 25 15.26 469 2 3
2 3 1024.04 1 15.26 1857 2 6
3 7 1523.40 38 15.05 2348 2 5
4 13 1264.88 18 15.08 2051 2 4
5 13 685.88 18 15.16 1301 2 4
6 13 253.92 18 15.26 717 2 4
7 8 0.08 165 15.28 333 2 11

Cycle 2 GMT 27/ 3/2019 8:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 24 15.30 483 2 2
2 10 1020.00 2 15.21 1795 2 4
3 7 1506.56 74 14.98 2311 2 4
4 13 277.12 18 15.26 745 2 4
5 8 0.16 165 15.30 328 2 8

Cycle 1 GMT 26/ 3/2019 9: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 23 15.45 428 3 3
2 10 1029.96 3 15.25 1776 2 3
3 3 1027.80 1 15.29 1834 2 4
4 7 999.08 74 15.13 1670 2 7
5 8 0.04 165 15.34 334 2 10

Cycle 0 GMT 25/ 3/2019 22:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.28 22 15.59 504 3 3
2 7 179.56 74 15.55 500 3 3
3 8 0.16 240 15.52 262 3 10