SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8189 WMO= 5902337


Cycle 11 GMT 4/ 2/2014 5: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 29 10.03 339 4 6
2 1024.68 1 12.19 1464 5 6
3 1020.56 1 12.25 1446 5 5
4 2004.48 70 11.18 2662 5 7
5 1549.52 25 9.08 1704 4 7
6 801.56 25 8.72 962 4 9
7 147.92 24 8.29 355 4 7
8 3.08 25 8.25 221 4 5
9 0.24 250 11.71 291 4 35

Cycle 10 GMT 25/ 1/2014 5:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.56 29 13.65 464 5 7
2 2001.36 70 12.01 2659 4 8
3 1095.84 25 7.79 1092 4 9
4 643.84 24 8.03 731 4 10
5 29.52 25 8.25 228 4 6
6 -0.04 251 10.80 257 4 27

Cycle 9 GMT 15/ 1/2014 5:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.36 29 13.78 446 5 7
2 2003.36 70 9.58 2125 4 6
3 1248.76 25 12.64 1746 5 14
4 517.40 24 13.14 899 5 14
5 0.20 250 13.92 319 5 22

Cycle 8 GMT 5/ 1/2014 6:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 27 14.29 482 6 7
2 1050.24 1 12.06 1553 5 6
3 2002.64 70 12.83 2894 5 8
4 1281.32 25 13.24 1953 6 13
5 594.92 25 13.65 1036 6 13
6 87.80 25 13.85 446 5 12
7 -0.20 251 10.11 234 5 15

Cycle 7 GMT 26/12/2013 6:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.68 27 14.48 482 6 7
2 2003.84 70 13.06 2873 6 7
3 1261.60 25 13.43 1956 6 12
4 539.88 24 13.89 999 6 14
5 18.96 24 14.40 360 6 10
6 0.20 251 14.02 322 6 30

Cycle 6 GMT 16/12/2013 7:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.20 28 14.48 464 6 8
2 1504.40 70 13.29 2242 8 10
3 799.16 25 13.98 1322 6 13
4 148.88 24 14.52 506 6 11
5 0.20 251 14.15 319 6 25

Cycle 5 GMT 15/12/2013 7:52:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.24 27 14.48 446 6 7
2 1027.68 1 14.55 1714 6 7
3 1511.96 70 13.22 2281 7 8
4 834.92 25 13.90 1381 6 14
5 161.44 25 14.43 544 6 13
6 0.20 251 14.12 314 6 28

Cycle 4 GMT 14/12/2013 8:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 27 14.42 428 6 7
2 1000.96 3 14.55 1571 6 10
3 916.24 -1 14.55 1571 6 10
4 938.92 -1 14.55 1571 6 10
5 1504.80 70 13.13 2226 10 10
6 822.12 25 13.82 1351 6 14
7 146.72 24 14.41 496 6 11
8 0.24 251 14.10 303 6 25

Cycle 3 GMT 13/12/2013 8:46: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.64 27 14.68 464 6 7
2 937.76 -1 14.68 464 6 7
3 1008.64 71 13.40 1560 7 11
4 15.56 24 14.47 335 6 9
5 -0.12 251 14.03 296 6 27

Cycle 0 GMT 11/12/2013 20:38: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 70 14.57 436 145 8
2 66.96 25 14.46 376 6 8
3 0.08 250 14.18 278 6 29