SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8399 WMO= 5902412


Cycle 271 GMT 15/ 6/2022 5:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 42 10.55 452 3 3
2 3 967.64 -1 10.55 452 3 3
3 12 1054.56 8 7.30 1821 3 3
4 12 1129.76 40 7.04 1928 3 3
5 12 1129.96 160 7.07 1921 3 3
6 7 1093.28 26 7.15 1894 3 3
7 8 -0.04 190 10.75 295 3 3

Cycle 270 GMT 5/ 6/2022 12:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 41 10.55 457 3 3
2 12 1102.52 40 10.60 314 3 3
3 12 1107.92 160 7.23 1911 3 3
4 7 1099.44 26 7.30 1900 3 3
5 13 504.36 40 9.04 1063 3 3
6 8 0.16 190 10.79 293 3 4

Cycle 269 GMT 26/ 5/2022 18:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 45 10.64 447 3 3
2 3 884.32 -2 10.64 447 3 3
3 3 1025.44 1 7.86 1806 3 3
4 12 1117.64 40 10.65 312 3 3
5 12 1122.52 160 7.29 1925 3 3
6 7 1111.16 26 7.30 1931 3 3
7 13 355.64 40 9.58 843 3 3
8 13 16.20 40 10.72 316 3 3
9 8 -0.08 190 10.77 304 3 4

Cycle 268 GMT 17/ 5/2022 0:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 43 10.62 474 3 3
2 12 1072.36 8 8.09 1860 3 3
3 12 2002.44 40 5.17 3431 3 3
4 12 2003.64 160 5.12 3414 3 3
5 7 2004.92 26 5.11 3338 3 3
6 13 1986.84 40 5.18 3329 3 3
7 13 1970.56 40 5.11 3315 3 3
8 13 1957.84 40 5.08 3303 3 3
9 13 1942.92 40 5.19 3242 2 3
10 13 1926.00 40 5.21 3218 3 3
11 13 1903.64 40 5.18 3184 2 3
12 13 1875.40 40 5.18 3164 3 3
13 13 1849.64 40 5.13 3158 2 3
14 13 1810.44 40 5.27 3078 2 3
15 13 1756.60 40 5.74 2844 3 3
16 13 1682.64 40 5.84 2742 2 3
17 13 1594.12 40 6.10 2593 3 3
18 13 1475.92 40 6.36 2444 3 3
19 13 1223.72 40 6.98 2090 3 3
20 13 815.56 40 8.15 1522 3 3
21 13 119.04 40 10.39 480 3 3
22 8 0.04 190 10.81 301 3 3

Cycle 267 GMT 15/ 5/2022 17:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 42 10.69 471 3 3
2 12 1107.72 8 7.80 1933 3 3
3 12 1151.04 40 7.68 1980 3 3
4 12 1155.48 160 7.73 1981 3 3
5 7 1129.88 26 7.81 1958 3 3
6 13 33.40 40 10.75 344 3 3
7 8 -0.08 190 10.85 302 3 3

Cycle 266 GMT 6/ 5/2022 0: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 36 10.72 440 3 3
2 10 1002.84 4 8.42 1753 3 3
3 3 1080.12 3 8.15 1876 3 3
4 3 1044.36 2 8.33 1827 3 3
5 12 1112.04 40 10.74 314 3 3
6 12 1117.16 160 7.85 1947 3 3
7 7 1103.84 26 7.94 1933 3 3
8 13 73.16 40 10.66 412 3 3
9 8 0.08 190 10.87 307 3 9

Cycle 265 GMT 26/ 4/2022 6:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 89 10.72 463 3 3
2 3 62.08 -15 10.72 463 3 3
3 3 443.28 -9 10.72 463 3 3
4 7 1154.56 26 7.84 1982 3 3
5 13 1080.32 40 7.98 1903 3 3
6 13 954.36 40 8.35 1724 3 3
7 13 371.72 40 9.80 877 3 3
8 8 0.12 190 10.88 303 3 3

Cycle 264 GMT 25/ 4/2022 14:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 41 10.71 463 3 3
2 3 1032.00 1 8.32 1828 3 3
3 3 1017.68 1 8.49 1793 3 3
4 12 1098.84 8 7.94 1916 3 3
5 12 2001.84 40 5.84 3223 3 3
6 12 2003.04 160 5.47 3433 3 3
7 7 1988.92 26 5.40 3402 3 3
8 13 1888.76 40 6.12 3047 3 3
9 13 1771.60 40 6.44 2869 3 3
10 13 1647.64 40 6.64 2698 3 3
11 13 1519.52 40 6.96 2524 2 3
12 13 934.56 40 8.27 1705 2 3
13 13 110.60 40 10.55 469 3 3
14 8 0.04 190 10.88 301 3 3

Cycle 263 GMT 24/ 4/2022 11:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 43 10.67 466 3 3
2 3 963.88 -1 10.67 466 3 3
3 3 1036.28 1 8.37 1817 3 3
4 12 1117.84 8 7.89 1912 3 3
5 12 1153.96 40 7.82 1981 3 3
6 12 1158.16 160 7.88 1999 3 3
7 7 1132.68 26 7.97 1980 3 3
8 8 0.08 190 10.89 303 3 3

Cycle 262 GMT 14/ 4/2022 17:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1933.76 24 5.31 3149 3 3
2 3 1934.48 33 5.33 3155 3 3
3 3 1925.64 32 5.63 3114 2 3
4 7 1866.08 26 5.85 2999 3 3
5 13 1815.24 40 6.02 2935 2 3
6 13 1740.64 40 6.18 2816 2 3
7 13 1644.04 40 6.45 2686 2 3
8 13 1527.72 40 6.73 2519 2 3
9 13 1128.24 40 7.64 1980 3 3
10 13 723.76 40 8.72 1399 3 3
11 13 63.60 40 10.69 385 3 3
12 8 0.00 190 10.88 295 3 3

Cycle 261

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 2088.88 24 5.07 3342 3 3
2 3 2090.00 38 5.04 3302 3 3
3 3 2172.00 41 5.06 3345 2 3
4 7 2182.92 26 5.10 3357 3 3
5 13 2181.16 40 5.09 3384 2 3
6 13 2179.40 40 5.10 3422 2 3
7 13 2177.08 40 5.10 3440 2 3
8 13 2177.80 40 5.11 3445 2 3
9 13 2178.56 40 5.11 3444 2 3
10 13 2178.16 40 5.11 3456 2 3
11 13 2178.12 40 5.11 3447 2 3
12 13 2172.44 40 5.13 3452 2 3
13 13 2166.52 40 5.12 3457 2 3
14 13 2165.16 40 5.12 3450 2 3
15 13 2163.84 40 5.12 3458 2 3
16 13 2160.36 40 5.11 3462 2 3
17 13 2155.60 40 5.17 3444 2 3
18 13 2150.56 40 5.12 3456 2 3
19 13 2147.08 40 5.24 3427 2 3
20 13 2147.00 40 5.12 3446 2 3
21 13 2143.36 40 5.13 3438 3 3
22 13 2137.68 40 5.11 3451 2 3
23 13 2129.84 40 5.11 3453 2 3
24 13 2122.16 40 5.13 3441 2 3
25 13 2114.64 40 5.13 3445 2 3
26 13 2110.04 40 5.11 3452 3 3
27 13 2106.52 40 5.16 3421 3 3
28 13 2099.48 40 5.14 3428 3 3
29 13 2088.28 40 5.12 3475 2 3
30 13 2073.44 40 5.15 3453 2 3
31 13 2061.40 40 5.13 3466 2 3
32 13 2051.36 40 5.18 3459 2 3
33 13 2045.52 40 5.19 3452 2 3
34 13 2040.08 40 5.16 3441 3 3
35 13 2039.12 509 4.97 3070 3 3
36 14 1976.64 140 5.09 3324 3 3

Cycle 260

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 41 10.47 444 3 3
2 12 1089.40 8 7.06 1849 3 3
3 12 2002.64 40 4.95 2734 3 3
4 12 2004.20 160 4.82 2500 3 3
5 7 2011.92 26 4.84 2299 3 3
6 13 2043.56 40 4.93 2651 2 3
7 13 2067.80 40 4.95 2748 2 3
8 13 2079.72 40 4.97 2788 2 3
9 13 2082.28 40 4.97 2816 2 3
10 13 2083.16 40 4.97 2839 2 3
11 13 2083.60 40 4.97 2857 2 3
12 13 2082.20 40 4.98 2873 2 3
13 13 2085.24 40 4.98 2887 2 3
14 13 2084.56 40 4.98 2901 2 3
15 13 2082.88 40 4.99 2912 3 3
16 13 2081.32 40 4.99 2925 2 3
17 13 2083.24 40 4.99 2936 3 3
18 13 2086.12 40 5.00 2948 3 3
19 13 2089.80 40 5.01 2955 2 3
20 13 2087.92 40 5.00 2969 3 3
21 13 2081.12 40 5.00 2979 3 3
22 13 2084.24 40 5.00 2989 3 3
23 13 2087.88 40 5.01 2999 2 3
24 13 2087.88 40 5.01 3007 2 3
25 13 2085.88 40 5.01 3016 2 3
26 13 2080.44 40 5.01 3024 2 3
27 13 2080.08 40 5.01 3030 3 3
28 13 2089.72 40 5.01 3039 2 3
29 13 2090.56 40 5.02 3045 3 3
30 13 2087.76 40 5.03 3083 2 3
31 13 2085.84 40 5.03 3098 3 3
32 13 2086.76 40 5.03 3112 3 3
33 13 2086.36 40 5.05 3114 3 3
34 13 2087.76 40 5.04 3127 3 3
35 13 2087.76 40 5.04 3134 2 3
36 13 2087.28 521 4.82 2528 3 3
37 14 2081.80 140 5.03 3225 3 3

Cycle 259 GMT 11/ 4/2022 21:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 37 10.56 442 3 3
2 10 1033.72 4 7.75 1805 3 3
3 3 1035.40 1 7.80 1800 3 3
4 3 1019.36 1 7.67 1800 3 3
5 12 1111.44 8 6.92 1898 3 3
6 12 1156.08 40 6.87 1961 3 3
7 12 1160.72 160 6.48 1952 3 3
8 7 1143.64 26 6.14 1946 3 3
9 13 228.04 40 9.80 642 3 3
10 13 38.40 40 10.53 348 3 3
11 13 2.28 40 10.69 292 3 3
12 8 -0.08 190 10.68 296 3 4

Cycle 258 GMT 2/ 4/2022 3:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 43 10.72 466 3 3
2 3 958.56 -1 10.72 466 3 3
3 3 1030.72 1 8.16 1826 3 3
4 12 1105.28 40 10.79 319 3 3
5 12 1110.72 160 7.17 1929 3 3
6 7 1102.28 26 6.82 1910 3 3
7 13 514.04 40 8.97 1083 3 3
8 13 37.68 40 10.62 345 3 3
9 8 0.00 190 10.74 298 3 3

Cycle 257 GMT 23/ 3/2022 9:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 36 10.96 456 3 3
2 10 1026.20 4 9.03 1802 3 3
3 3 1063.88 2 8.83 1864 3 3
4 3 1027.36 1 9.00 1837 3 3
5 12 1098.88 40 10.85 314 3 3
6 12 1104.28 160 7.42 1925 3 3
7 7 1093.68 26 7.30 1905 3 3
8 13 196.24 40 10.27 599 3 3
9 8 -0.08 190 10.89 301 3 4

Cycle 256 GMT 13/ 3/2022 15:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 11.14 453 3 3
2 10 1017.96 5 9.11 1796 3 3
3 3 1087.44 3 8.65 1898 3 3
4 3 1048.16 2 8.80 1858 3 3
5 12 1107.44 8 8.37 1941 3 3
6 12 2001.60 40 5.77 3298 3 3
7 12 2001.68 160 4.82 2463 3 3
8 7 1992.36 26 4.87 2448 3 3
9 13 1946.56 40 5.73 3231 3 3
10 13 1885.60 40 6.09 3108 3 3
11 13 1805.00 40 6.53 2933 3 3
12 13 1701.04 40 6.89 2783 2 3
13 13 1576.92 40 7.22 2619 3 3
14 13 1149.80 40 8.13 2016 2 3
15 13 413.72 40 9.88 951 3 3
16 13 27.64 40 10.95 340 3 3
17 8 0.08 190 10.98 303 3 3

Cycle 255 GMT 12/ 3/2022 12: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 31 11.89 454 3 3
2 10 1027.48 5 10.05 1827 3 3
3 3 1027.00 1 9.84 1846 3 3
4 3 1015.96 1 9.92 1831 3 3
5 12 1098.40 8 8.06 1883 3 3
6 12 1156.44 40 7.39 1965 3 3
7 12 1160.68 160 5.16 1845 3 3
8 7 1150.40 26 6.16 1935 3 3
9 13 1041.84 40 7.89 1840 3 3
10 13 515.12 40 9.53 1095 3 3
11 13 50.92 40 11.06 375 3 3
12 8 0.00 190 11.14 301 3 3

Cycle 254 GMT 2/ 3/2022 17:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 32 12.45 486 3 3
2 10 1021.76 4 10.99 1865 3 3
3 12 1086.20 40 11.69 329 3 3
4 12 1091.76 160 4.71 1685 3 3
5 7 1112.96 26 7.01 1912 3 3
6 13 1193.52 40 7.40 2016 3 3
7 13 1142.20 40 7.90 1967 3 3
8 13 1026.72 40 8.52 1840 3 3
9 13 486.04 40 10.39 1058 3 3
10 13 34.60 40 11.88 365 3 3
11 8 0.04 190 11.72 311 3 3

Cycle 253 GMT 20/ 2/2022 22:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 31 13.55 477 3 3
2 3 1031.92 1 11.60 1898 3 3
3 12 1096.96 40 12.31 335 3 3
4 12 1102.48 160 5.46 1845 3 3
5 7 1102.16 27 8.47 1949 3 3
6 13 986.16 40 9.17 1789 3 3
7 13 289.28 40 11.51 760 3 3
8 13 10.40 40 12.46 330 3 3
9 8 0.00 190 12.20 318 3 5

Cycle 252 GMT 11/ 2/2022 4:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 31 13.84 481 3 3
2 12 1088.44 8 11.10 1962 3 3
3 12 1978.28 40 8.62 3213 2 3
4 12 1976.88 160 5.51 2878 3 3
5 7 1949.52 26 8.03 3195 3 3
6 13 1403.20 40 9.78 2424 2 3
7 13 825.12 40 10.94 1578 3 3
8 13 40.16 40 13.23 385 3 3
9 8 0.08 190 12.94 324 3 5

Cycle 251 GMT 10/ 2/2022 0:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 30 13.91 485 3 3
2 3 1016.00 1 10.79 1869 3 3
3 12 1101.84 8 4.73 1623 3 3
4 12 1155.44 40 5.02 1830 3 3
5 12 1160.32 160 4.62 1615 3 3
6 7 1184.56 26 8.36 2032 3 3
7 13 1259.56 40 8.40 2137 3 3
8 13 1197.00 40 8.87 2060 3 3
9 13 1073.88 40 9.41 1923 3 3
10 13 203.76 40 12.97 643 3 3
11 8 -0.04 190 13.40 329 3 4

Cycle 250 GMT 31/ 1/2022 5:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 31 14.00 480 3 3
2 12 1069.48 40 11.51 324 3 3
3 12 1075.52 160 4.62 1556 3 3
4 7 1101.48 27 8.08 1918 3 3
5 13 1193.80 40 7.98 2043 3 3
6 13 1167.56 40 8.72 2028 2 3
7 13 1055.56 40 9.46 1902 3 3
8 13 352.04 40 12.80 877 3 3
9 8 0.20 190 13.74 328 3 3

Cycle 249 GMT 21/ 1/2022 10:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 30 14.08 497 3 3
2 3 1017.36 1 10.88 1849 3 3
3 12 1094.92 40 12.14 323 3 3
4 12 1100.32 160 5.33 1836 3 3
5 7 1105.92 26 9.26 1966 3 3
6 13 991.16 40 9.86 1804 3 3
7 13 400.32 40 12.74 961 3 3
8 8 0.00 190 13.83 331 3 5

Cycle 248 GMT 11/ 1/2022 16:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 31 14.00 496 3 3
2 12 1095.72 8 11.10 1961 3 3
3 12 1991.24 40 8.56 3251 2 3
4 12 1990.16 160 5.29 2906 3 3
5 7 1966.96 26 8.69 3221 3 3
6 13 1564.08 40 10.70 2671 3 3
7 13 964.32 40 12.05 1781 2 3
8 13 29.60 40 14.06 377 3 3
9 8 0.04 190 13.97 331 3 10

Cycle 247 GMT 10/ 1/2022 12:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 30 14.06 491 3 3
2 12 1099.28 8 4.72 1566 3 3
3 12 1155.20 40 5.05 1857 3 3
4 12 1160.16 160 4.62 1629 3 3
5 7 1185.52 26 8.59 2053 3 3
6 13 1259.52 40 9.14 2158 3 3
7 13 1175.92 40 10.07 2082 3 3
8 13 781.96 40 11.81 1528 3 3
9 13 32.00 40 14.04 377 3 3
10 8 -0.12 190 14.01 334 3 11

Cycle 246 GMT 31/12/2021 17:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 14.08 487 3 3
2 12 1087.48 40 11.63 316 3 3
3 12 1093.56 160 4.64 1625 3 3
4 7 1120.12 27 8.53 1950 3 3
5 13 1212.44 40 9.14 2087 3 3
6 13 1155.36 40 9.95 2033 3 3
7 13 896.12 40 11.22 1685 3 3
8 13 61.64 40 13.96 422 3 3
9 8 0.08 190 14.04 336 3 11

Cycle 245 GMT 21/12/2021 23:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 30 14.20 491 3 3
2 12 1082.16 40 12.09 321 3 3
3 12 1087.72 160 5.34 1848 3 3
4 7 1092.88 27 9.47 1956 3 3
5 13 978.24 40 10.78 1801 3 3
6 13 120.96 40 13.85 516 3 3
7 8 0.04 190 14.12 334 3 8

Cycle 244 GMT 12/12/2021 5: 5: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 31 14.14 491 3 3
2 12 1070.72 8 11.05 1924 3 3
3 12 1986.40 40 8.30 3231 3 3
4 12 1984.76 160 5.09 2925 3 3
5 7 1961.56 26 9.13 3230 3 3
6 13 1698.80 40 10.81 2880 3 3
7 13 984.76 40 12.32 1812 3 3
8 13 21.80 40 14.18 371 3 3
9 8 0.36 190 14.23 339 3 14

Cycle 243 GMT 11/12/2021 0:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 14.07 489 3 3
2 12 1085.80 8 4.71 1525 3 3
3 12 1150.04 40 5.13 1876 3 3
4 12 1154.44 160 4.64 1684 3 3
5 7 1175.16 26 8.94 2035 3 3
6 13 1248.80 40 9.92 2165 3 3
7 13 1153.64 40 10.66 2030 3 3
8 13 584.40 40 12.62 1242 3 3
9 8 -0.08 190 14.14 341 3 7

Cycle 242 GMT 1/12/2021 6: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 14.14 478 3 3
2 12 1075.48 40 11.62 316 3 3
3 12 1080.92 160 4.66 1696 3 3
4 7 1104.56 27 8.88 1926 3 3
5 13 1197.28 40 9.64 2086 3 3
6 13 1134.24 40 10.32 2020 3 3
7 13 859.80 40 11.57 1642 3 3
8 13 41.96 40 14.06 393 3 3
9 8 0.00 190 14.16 339 3 14

Cycle 241 GMT 21/11/2021 11:38: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 14.18 493 3 3
2 12 1084.72 40 12.02 325 3 3
3 12 1091.08 160 5.80 1845 3 3
4 7 1093.52 27 9.63 1951 3 3
5 13 835.20 40 11.75 1605 3 3
6 13 22.64 40 14.13 357 3 3
7 8 0.04 190 14.22 329 3 15

Cycle 240 GMT 11/11/2021 17:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 31 14.13 504 3 3
2 12 1090.80 8 11.04 1946 3 3
3 12 1993.48 40 8.19 3243 3 3
4 12 1992.12 160 5.13 3048 3 3
5 7 1970.56 26 9.45 3258 3 3
6 13 1837.96 40 10.54 3065 3 3
7 13 1076.08 40 12.37 1949 3 3
8 13 60.64 40 14.12 423 3 3
9 8 0.04 190 14.27 337 3 13

Cycle 239 GMT 10/11/2021 13:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 30 14.07 492 3 3
2 12 1080.20 8 4.70 1511 3 3
3 12 1159.52 40 5.09 1900 3 3
4 12 1164.52 160 4.66 1762 3 3
5 7 1188.80 26 9.12 2066 3 3
6 13 1254.64 40 10.26 2179 3 3
7 13 1155.44 40 10.91 2072 3 3
8 13 446.44 40 13.16 1038 3 3
9 8 -0.04 190 14.21 337 3 8

Cycle 238 GMT 31/10/2021 18:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 30 14.01 498 3 3
2 12 1097.32 40 11.65 318 3 3
3 12 1103.48 160 4.69 1813 3 3
4 7 1130.44 27 9.14 1977 3 3
5 13 1219.84 40 10.11 2126 3 3
6 13 1145.56 40 10.66 2047 3 3
7 13 729.32 40 12.29 1458 3 3
8 8 0.16 190 14.20 335 3 6

Cycle 237 GMT 22/10/2021 0:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 30 14.12 495 3 3
2 12 1097.56 40 12.04 324 3 3
3 12 1103.44 160 6.01 1872 3 3
4 7 1103.76 27 9.71 1966 3 3
5 13 703.96 40 12.31 1406 3 3
6 8 0.12 190 14.20 331 3 3

Cycle 236 GMT 12/10/2021 6:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 30 14.03 507 3 3
2 12 1087.92 8 10.96 1941 3 3
3 12 1991.08 40 8.05 3233 2 3
4 12 1990.24 160 5.04 3076 3 3
5 7 1971.44 26 9.67 3285 3 3
6 13 1847.12 40 10.93 3069 3 3
7 13 967.80 40 12.67 1799 3 3
8 13 37.08 40 14.16 383 3 3
9 8 0.00 190 14.29 335 3 13

Cycle 235 GMT 11/10/2021 2:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 30 14.01 489 3 3
2 12 1079.36 8 4.70 1508 3 3
3 12 1161.04 40 4.98 1888 3 3
4 12 1165.92 160 4.66 1783 3 3
5 7 1190.44 26 9.10 2060 3 3
6 13 1258.80 40 10.32 2176 3 3
7 13 1161.96 40 10.98 2046 3 3
8 13 458.88 40 13.19 1040 3 3
9 8 0.08 190 14.21 339 3 5

Cycle 234 GMT 1/10/2021 7:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 14.07 492 3 3
2 12 1097.40 40 11.67 324 3 3
3 12 1103.32 160 5.01 1826 3 3
4 7 1118.36 27 9.23 1967 3 3
5 13 1024.84 40 10.91 1872 3 3
6 13 602.24 40 12.60 1270 3 3
7 8 0.12 190 14.19 333 3 5

Cycle 233 GMT 21/ 9/2021 13:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 14.14 490 3 3
2 12 1084.12 40 12.10 322 3 3
3 12 1089.56 160 6.45 1858 3 3
4 7 1083.28 27 9.89 1941 3 3
5 13 377.04 40 13.28 922 3 3
6 8 -0.08 190 14.19 335 3 6

Cycle 232 GMT 11/ 9/2021 19:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 30 14.08 496 3 3
2 12 1092.88 8 10.92 1964 3 3
3 12 2000.08 40 7.94 3232 3 3
4 12 1998.80 160 5.06 3183 3 3
5 7 1979.48 26 9.95 3296 3 3
6 13 1852.52 40 11.19 3100 3 3
7 13 1083.12 40 12.60 1963 3 3
8 13 29.96 40 14.16 375 3 3
9 8 0.12 190 14.28 338 3 12

Cycle 231 GMT 10/ 9/2021 15:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 29 14.09 494 3 3
2 3 1016.96 1 10.06 1854 3 3
3 12 1106.84 8 4.71 1538 3 3
4 12 1153.64 40 5.12 1900 3 3
5 12 1158.32 160 4.72 1868 3 3
6 7 1179.64 26 9.39 2056 3 3
7 13 1213.16 40 10.86 2122 3 3
8 13 1096.36 40 11.47 1970 3 3
9 13 183.72 40 13.83 617 3 3
10 8 0.04 190 14.23 338 3 8

Cycle 230 GMT 31/ 8/2021 20:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 29 14.08 495 3 3
2 12 1091.08 40 11.66 320 3 3
3 12 1097.84 160 5.42 1838 3 3
4 7 1108.08 27 9.48 1980 3 3
5 13 987.92 40 11.35 1819 3 3
6 13 117.60 40 13.93 509 3 3
7 8 0.04 190 14.22 329 3 10

Cycle 229 GMT 22/ 8/2021 2:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 31 14.13 490 3 3
2 3 956.04 -1 14.13 490 3 3
3 3 1020.44 1 10.02 1846 3 3
4 12 1109.12 40 12.06 325 3 3
5 12 1114.44 160 6.59 1901 3 3
6 7 1106.48 27 10.01 1977 3 3
7 13 360.16 40 13.41 892 3 3
8 8 0.00 190 14.21 337 3 6

Cycle 228 GMT 12/ 8/2021 8:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 31 14.06 496 3 3
2 3 964.32 -1 14.06 496 3 3
3 3 1039.44 1 10.36 1878 3 3
4 12 1100.32 8 10.79 1970 3 3
5 12 1987.76 40 7.61 3226 3 3
6 12 1986.68 160 5.09 3255 3 3
7 7 1966.84 26 10.17 3292 3 3
8 13 1833.76 40 11.45 3083 3 3
9 13 947.48 40 12.85 1780 3 3
10 13 31.96 40 14.15 384 3 3
11 8 0.12 190 14.29 336 3 12

Cycle 227 GMT 11/ 8/2021 4:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 31 14.06 503 3 3
2 3 954.32 -1 14.06 503 3 3
3 3 1027.12 1 10.10 1856 3 3
4 12 1104.80 8 4.72 1562 3 3
5 12 1153.00 40 5.21 1895 3 3
6 12 1157.72 160 4.86 1888 3 3
7 7 1175.64 26 9.59 2052 3 3
8 13 1113.44 40 11.34 1990 3 3
9 13 716.04 40 12.74 1435 3 3
10 8 0.16 190 14.23 344 3 5

Cycle 226 GMT 1/ 8/2021 10:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 31 14.07 498 3 3
2 12 1080.16 40 11.65 329 3 3
3 12 1085.92 160 5.58 1833 3 3
4 7 1089.16 27 9.69 1948 3 3
5 13 963.36 40 11.54 1788 3 3
6 13 82.44 40 14.01 446 3 3
7 8 -0.08 190 14.22 330 3 15

Cycle 225 GMT 22/ 7/2021 16:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 29 14.15 495 3 3
2 3 1027.08 1 10.33 1862 3 3
3 3 1015.36 1 9.43 1825 3 3
4 12 1104.60 40 12.04 327 3 3
5 12 1109.48 160 6.90 1882 3 3
6 7 1096.64 27 10.20 1942 3 3
7 13 183.92 40 13.79 617 3 3
8 8 -0.04 190 14.21 337 3 6

Cycle 224 GMT 12/ 7/2021 23: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 30 14.10 494 3 3
2 3 1016.88 1 9.77 1832 3 3
3 12 1098.84 8 10.63 1964 3 3
4 12 2001.04 40 7.36 3228 2 3
5 12 2000.36 160 5.07 3305 3 3
6 7 1984.60 26 10.29 3297 3 3
7 13 1857.00 40 11.58 3120 2 3
8 13 1232.64 40 12.54 2184 2 3
9 13 110.68 40 14.05 508 3 3
10 8 0.04 190 14.30 337 3 10

Cycle 223 GMT 11/ 7/2021 19:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 14.06 494 3 3
2 12 1097.28 8 4.72 1588 3 3
3 12 1152.88 40 5.33 1893 3 3
4 12 1157.52 160 5.10 1912 3 3
5 7 1168.52 26 9.82 2042 3 3
6 13 1058.12 40 11.69 1907 3 3
7 13 190.72 40 13.83 622 3 3
8 8 0.16 190 14.24 335 3 6

Cycle 222 GMT 2/ 7/2021 1:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 14.10 482 3 3
2 3 938.00 -1 14.10 482 3 3
3 12 1091.24 40 11.72 317 3 3
4 12 1097.80 160 5.76 1874 3 3
5 7 1104.64 27 9.92 1981 3 3
6 13 977.04 40 11.76 1809 3 3
7 13 18.44 40 14.11 357 3 3
8 8 0.20 190 14.23 332 3 10

Cycle 221 GMT 22/ 6/2021 7:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 31 14.15 504 3 3
2 12 1078.36 8 5.57 1817 3 3
3 12 1154.76 140 6.85 1951 3 3
4 12 1159.80 40 6.92 1982 3 3
5 7 1145.32 26 10.14 2044 3 3
6 13 97.48 40 13.96 481 3 3
7 8 0.04 190 14.23 329 3 9

Cycle 220 GMT 12/ 6/2021 13:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 30 14.13 488 3 3
2 12 1086.52 8 10.50 1948 3 3
3 12 2002.68 140 5.69 3281 2 3
4 12 1995.84 40 5.29 3504 3 3
5 7 1987.04 26 10.30 3321 3 3
6 13 1857.00 40 11.64 3121 3 3
7 13 1098.56 40 12.71 1995 3 3
8 13 63.72 40 14.12 431 3 3
9 8 0.12 190 14.30 336 3 15

Cycle 219 GMT 11/ 6/2021 9:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 32 14.08 489 3 3
2 3 954.56 -1 14.08 489 3 3
3 3 1025.56 1 9.55 1839 3 3
4 12 1122.48 8 4.74 1648 3 3
5 12 1153.84 140 5.32 1915 3 3
6 12 1163.96 40 5.81 1950 3 3
7 7 1156.32 26 9.89 2059 3 3
8 13 899.44 40 12.20 1711 3 3
9 13 54.92 40 14.05 421 3 3
10 8 0.00 190 14.22 338 3 13

Cycle 218 GMT 1/ 6/2021 15:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 31 14.08 495 3 3
2 12 1091.84 8 4.76 1771 3 3
3 12 1160.32 140 5.85 1936 3 3
4 12 1169.84 40 6.16 1998 3 3
5 7 1159.44 26 10.01 2055 3 3
6 13 725.00 40 12.61 1453 3 3
7 8 0.04 190 14.22 331 3 8

Cycle 217 GMT 22/ 5/2021 21:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 31 14.14 502 3 3
2 12 1095.84 8 5.89 1850 3 3
3 12 1155.20 140 7.06 1959 3 3
4 12 1159.20 40 7.16 1994 3 3
5 7 1143.28 26 10.25 2041 3 3
6 13 80.08 40 13.98 458 3 3
7 8 0.00 190 14.20 331 3 9

Cycle 216 GMT 13/ 5/2021 3:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 32 14.07 488 3 3
2 3 926.20 -1 14.07 488 3 3
3 12 1103.24 8 10.62 1971 3 3
4 12 2002.32 140 5.85 3333 3 3
5 12 1994.84 40 6.96 3259 3 3
6 7 1983.16 26 10.45 3308 3 3
7 13 1560.16 40 12.14 2677 3 3
8 13 495.24 40 13.48 1116 3 3
9 8 0.04 190 14.28 338 3 8

Cycle 215 GMT 11/ 5/2021 23:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 32 14.05 495 3 3
2 12 1093.40 8 4.75 1711 3 3
3 12 1163.36 140 5.57 1939 3 3
4 12 1175.04 40 6.20 1961 3 3
5 7 1167.00 26 10.09 2039 3 3
6 13 886.72 40 12.35 1673 3 3
7 13 34.04 40 14.08 380 3 3
8 8 0.24 190 14.20 343 3 17

Cycle 214 GMT 2/ 5/2021 5: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 31 14.09 492 3 3
2 12 1091.96 8 4.76 1760 3 3
3 12 1147.80 140 6.08 1930 3 3
4 12 1154.04 40 6.78 1942 3 3
5 7 1141.12 26 10.16 2020 3 3
6 13 419.64 40 13.32 991 3 3
7 8 -0.20 190 14.19 333 3 6

Cycle 213 GMT 22/ 4/2021 10:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 31 14.16 488 3 3
2 12 1088.04 8 6.35 1821 3 3
3 12 1107.32 140 7.58 1899 3 3
4 12 1107.76 40 7.82 1892 3 3
5 7 1088.76 26 10.48 1966 3 3
6 8 0.36 190 14.19 333 3 3

Cycle 212 GMT 12/ 4/2021 16:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 30 14.10 494 3 3
2 3 1052.80 2 10.80 1896 3 3
3 3 1016.24 1 9.39 1840 3 3
4 12 1109.20 8 10.74 1979 3 3
5 12 2001.40 140 6.96 3222 3 3
6 12 1991.00 40 7.50 3216 3 3
7 7 1973.92 26 10.52 3300 3 3
8 13 715.32 40 13.20 1436 3 3
9 13 19.40 40 14.18 359 3 3
10 8 -0.08 190 14.30 329 3 18

Cycle 211 GMT 11/ 4/2021 13: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 32 14.11 488 3 3
2 12 1089.96 8 4.72 1602 3 3
3 12 1111.88 140 5.34 1851 3 3
4 12 1124.56 40 6.54 1902 3 3
5 7 1118.88 26 10.38 1987 3 3
6 13 716.68 40 12.92 1434 3 3
7 13 37.40 40 14.09 383 3 3
8 8 -0.12 190 14.23 332 3 14

Cycle 210 GMT 1/ 4/2021 18:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 31 14.08 496 3 3
2 12 1101.32 140 12.15 330 3 3
3 12 1117.96 40 5.30 1852 3 3
4 7 1129.20 27 9.42 1963 3 3
5 13 1163.68 40 10.66 2053 3 3
6 13 1050.04 40 11.54 1923 3 3
7 13 70.16 40 14.00 433 3 3
8 8 0.16 190 14.20 328 3 7

Cycle 209 GMT 23/ 3/2021 0:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 31 14.16 490 3 3
2 12 1126.80 140 6.90 1919 3 3
3 7 1125.72 26 10.35 2005 3 3
4 13 712.04 40 12.77 1428 3 3
5 13 34.68 40 14.07 384 3 3
6 8 -0.04 190 14.19 336 3 17

Cycle 208 GMT 13/ 3/2021 6:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 32 14.14 474 3 3
2 3 945.60 -1 14.14 474 3 3
3 12 1122.96 8 10.63 2000 3 3
4 12 2001.40 140 6.81 3228 2 3
5 7 1982.72 26 10.36 3302 3 3
6 13 1255.56 40 12.49 2223 2 3
7 13 185.76 40 13.91 625 3 3
8 8 0.08 190 14.27 336 3 8

Cycle 207 GMT 12/ 3/2021 2:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 32 14.10 490 3 3
2 12 1126.32 140 5.56 1873 3 3
3 7 1137.92 26 10.01 2020 3 3
4 13 1023.00 40 11.89 1890 3 3
5 13 266.12 40 13.68 753 3 3
6 8 0.12 190 14.20 337 3 4

Cycle 206 GMT 2/ 3/2021 8: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 31 14.05 500 3 3
2 12 1131.64 140 5.85 1889 3 3
3 7 1136.56 26 10.13 2006 3 3
4 13 1019.88 40 11.93 1874 3 3
5 13 64.16 40 14.02 429 3 3
6 8 0.08 190 14.20 332 3 9

Cycle 205 GMT 20/ 2/2021 13:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 31 14.19 493 3 3
2 12 1128.24 140 7.16 1923 3 3
3 7 1126.12 26 10.45 2015 3 3
4 13 542.16 44 13.10 1184 3 3
5 13 26.60 44 14.07 375 3 3
6 8 -0.12 190 14.17 339 3 35

Cycle 204 GMT 10/ 2/2021 19:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 32 14.12 486 3 3
2 12 1119.48 8 10.60 2000 3 3
3 12 2000.96 140 6.94 3242 3 3
4 7 1982.16 26 10.44 3300 3 3
5 13 1365.64 44 12.29 2392 3 3
6 13 103.32 44 14.04 495 3 3
7 8 0.04 190 14.27 337 3 10

Cycle 203 GMT 9/ 2/2021 16: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 31 14.05 489 3 3
2 12 1127.20 140 5.84 1883 3 3
3 7 1133.00 26 10.29 1990 3 3
4 13 1008.12 44 12.04 1841 3 3
5 13 87.56 44 13.99 458 3 3
6 8 0.00 190 14.20 335 3 15

Cycle 202 GMT 30/ 1/2021 21:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 31 14.06 490 3 3
2 12 1124.52 140 6.14 1887 3 3
3 7 1128.68 26 10.34 1991 3 3
4 13 1001.00 44 12.00 1845 3 3
5 13 39.52 44 14.07 391 3 3
6 8 0.00 190 14.20 334 3 11

Cycle 201 GMT 21/ 1/2021 3:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 31 14.18 490 3 3
2 12 1130.28 128 7.20 1928 3 3
3 7 1129.52 26 10.54 1988 3 3
4 13 568.72 44 13.07 1204 3 3
5 13 16.60 44 14.11 353 3 3
6 8 -0.12 190 14.19 334 3 28

Cycle 200 GMT 11/ 1/2021 9:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 32 14.13 487 3 3
2 12 1110.72 8 10.76 1981 3 3
3 12 1994.28 128 7.24 3227 2 3
4 7 1975.56 26 10.45 3290 3 3
5 13 1102.84 44 12.62 1996 2 3
6 13 77.20 44 14.08 454 3 3
7 8 0.08 190 14.29 332 3 14

Cycle 199 GMT 10/ 1/2021 5:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 31 14.08 502 3 3
2 12 1135.64 128 5.98 1899 3 3
3 7 1143.60 26 10.33 2008 3 3
4 13 1019.32 44 12.01 1887 3 3
5 13 112.88 44 13.94 513 3 3
6 8 0.00 190 14.21 333 3 12

Cycle 198 GMT 31/12/2020 11: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 31 14.09 496 3 3
2 12 1111.20 128 6.33 1879 3 3
3 7 1113.80 26 10.31 2010 3 3
4 13 860.56 44 12.40 1657 3 3
5 13 40.84 44 14.06 395 3 3
6 8 0.08 190 14.20 334 3 13

Cycle 197 GMT 21/12/2020 17: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 31 14.15 487 3 3
2 12 1140.56 120 7.38 1951 3 3
3 7 1139.72 26 10.61 2044 3 3
4 13 718.88 38 12.87 1441 3 3
5 8 0.04 190 14.20 331 3 4

Cycle 196 GMT 11/12/2020 22:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 30 14.09 493 3 3
2 3 1031.08 1 11.02 1880 3 3
3 12 1121.72 7 10.90 1991 3 3
4 12 2001.00 120 7.39 3235 2 3
5 7 1984.64 26 10.41 3295 3 3
6 13 1238.56 38 12.54 2201 3 3
7 13 183.64 38 13.90 626 3 3
8 8 0.08 190 14.27 332 3 5

Cycle 195 GMT 10/12/2020 19:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 30 14.06 493 3 3
2 3 1015.08 1 10.69 1852 3 3
3 12 1121.12 120 6.33 1888 3 3
4 7 1125.76 26 10.47 1992 3 3
5 13 1010.88 38 12.18 1877 3 3
6 13 112.48 38 13.94 503 3 3
7 8 0.08 190 14.20 333 3 8

Cycle 194 GMT 1/12/2020 1:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 14.08 494 3 3
2 12 1120.36 120 6.62 1904 3 3
3 7 1123.28 26 10.56 1991 3 3
4 13 991.48 38 12.19 1846 3 3
5 13 44.28 38 14.06 395 3 3
6 8 0.00 190 14.19 335 3 9

Cycle 193 GMT 21/11/2020 7: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 14.12 497 3 3
2 12 1110.08 120 7.81 1910 3 3
3 7 1104.96 26 10.77 1985 3 3
4 13 535.00 38 13.19 1169 3 3
5 8 0.00 190 14.17 338 3 5

Cycle 192 GMT 11/11/2020 12:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 32 14.07 493 3 3
2 3 908.04 -2 14.07 493 3 3
3 3 1022.88 1 10.55 1863 3 3
4 12 1141.52 7 11.03 2037 3 3
5 12 2001.76 120 7.94 3249 2 3
6 7 1982.44 26 10.48 3288 3 3
7 13 1341.32 38 12.44 2359 3 3
8 13 93.60 38 14.03 488 3 3
9 8 0.04 190 14.26 342 3 7

Cycle 191 GMT 10/11/2020 9:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 25 14.06 493 3 3
2 10 1058.84 4 12.18 1911 3 3
3 3 1074.32 2 11.39 1959 3 3
4 3 1031.60 1 10.88 1883 3 3
5 12 1141.04 90 6.40 1935 3 3
6 7 1149.24 26 10.26 2067 3 3
7 13 1051.20 38 12.14 1937 3 3
8 13 341.80 38 13.56 882 3 3
9 8 0.04 190 14.17 345 3 6

Cycle 190 GMT 31/10/2020 14:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 31 14.09 498 3 3
2 3 951.80 -1 14.09 498 3 3
3 3 1026.60 1 10.72 1878 3 3
4 12 1140.96 90 6.88 1932 3 3
5 7 1148.72 26 10.34 2038 3 3
6 13 1025.68 38 12.15 1898 3 3
7 13 279.88 38 13.64 789 3 3
8 8 0.20 190 14.18 340 3 5

Cycle 189 GMT 21/10/2020 20:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 30 14.15 498 3 3
2 3 1038.08 1 11.48 1886 3 3
3 3 1019.64 1 10.70 1865 3 3
4 12 1134.00 90 8.34 1947 3 3
5 7 1132.64 26 10.75 2007 3 3
6 13 722.64 38 12.95 1444 3 3
7 8 0.04 190 14.20 339 3 4

Cycle 188 GMT 12/10/2020 2:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 25 14.14 487 3 3
2 10 1043.04 4 12.31 1912 3 3
3 10 1070.88 3 12.52 1992 3 3
4 3 1039.12 1 11.25 1900 3 3
5 3 1022.80 1 10.67 1855 3 3
6 12 1132.44 5 11.35 2033 3 3
7 12 2005.80 90 9.37 3301 2 3
8 7 1993.12 26 10.54 3296 3 3
9 13 925.56 38 13.05 1741 2 3
10 13 63.40 38 14.13 437 3 3
11 8 -0.04 190 14.30 339 3 9

Cycle 187 GMT 10/10/2020 23:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 30 14.16 492 3 3
2 3 973.04 -1 14.16 492 3 3
3 3 1040.04 1 11.08 1893 3 3
4 12 1150.72 14 7.87 1980 3 3
5 12 1998.80 130 5.09 3231 2 3
6 12 1998.60 90 6.67 3214 3 3
7 7 1988.96 26 10.18 3315 3 3
8 13 1579.40 38 12.19 2712 3 3
9 13 693.52 38 13.28 1421 3 3
10 13 14.28 38 14.21 361 3 3
11 8 -0.16 190 14.32 344 3 13

Cycle 186 GMT 30/ 9/2020 21:59: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 14.15 497 3 3
2 12 1110.04 14 8.15 1907 3 3
3 12 1989.76 130 5.05 3200 2 3
4 12 1988.88 87 6.59 3196 3 3
5 7 1979.12 26 10.17 3298 3 3
6 13 1710.60 38 11.99 2905 3 3
7 13 931.80 38 13.01 1756 3 3
8 13 26.20 38 14.18 380 3 3
9 8 -0.04 190 14.31 345 3 12

Cycle 185 GMT 20/ 9/2020 20:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 30 14.14 507 3 3
2 12 1134.92 14 8.01 1947 3 3
3 12 2005.76 130 5.12 3204 3 3
4 12 2006.24 87 6.60 3251 3 3
5 7 1998.40 26 10.28 3268 3 3
6 13 1728.76 38 12.00 2922 3 3
7 13 835.20 38 13.11 1634 3 3
8 8 0.08 190 14.29 343 3 4

Cycle 184 GMT 10/ 9/2020 19:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 14.17 486 3 3
2 3 958.24 -1 14.17 486 3 3
3 3 1025.84 1 10.84 1874 3 3
4 12 1136.20 14 7.71 1956 3 3
5 12 1999.48 130 5.08 3227 3 3
6 12 1999.28 82 6.75 3205 3 3
7 7 1989.76 26 10.23 3302 3 3
8 13 1723.44 38 12.00 2940 3 3
9 13 706.88 38 13.26 1439 3 3
10 8 0.04 190 14.30 345 3 5

Cycle 183 GMT 31/ 8/2020 17:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 31 14.16 503 3 3
2 3 957.88 -1 14.16 503 3 3
3 3 1027.24 1 10.82 1882 3 3
4 12 1134.64 14 7.98 1938 3 3
5 12 2001.52 130 5.05 3259 3 3
6 12 2001.80 82 6.69 3200 3 3
7 7 1992.88 26 10.25 3268 3 3
8 13 1717.60 38 12.03 2916 3 3
9 13 822.24 38 13.14 1610 3 3
10 13 72.12 38 14.13 448 3 3
11 8 -0.04 190 14.33 340 3 12

Cycle 182 GMT 21/ 8/2020 16:52: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 14.17 509 3 3
2 12 1134.84 14 8.02 1926 3 3
3 12 2001.36 130 5.10 3231 3 3
4 12 2001.36 68 6.60 3219 3 3
5 7 1994.16 26 10.27 3272 3 3
6 13 1739.32 38 12.00 2944 3 3
7 13 985.04 38 12.98 1839 3 3
8 13 84.08 38 14.11 465 3 3
9 8 0.12 190 14.33 340 3 13

Cycle 181 GMT 11/ 8/2020 15:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 14.11 503 3 3
2 12 1123.92 14 7.98 1927 3 3
3 12 1998.08 130 5.07 3248 3 3
4 12 1998.16 68 6.71 3206 3 3
5 7 1991.00 26 10.34 3253 3 3
6 13 1866.16 38 11.78 3103 3 3
7 13 1097.32 38 12.86 1989 3 3
8 13 59.84 38 14.14 433 3 3
9 8 0.16 190 14.32 342 3 14

Cycle 180 GMT 1/ 8/2020 14:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 31 14.11 508 3 3
2 12 1120.36 14 7.88 1941 3 3
3 12 1998.32 130 5.06 3239 3 3
4 12 1997.92 68 6.30 3283 3 3
5 7 1991.64 26 10.33 3277 3 3
6 13 1861.52 38 11.80 3121 3 3
7 13 976.28 38 12.96 1836 3 3
8 13 89.92 38 14.09 483 3 3
9 8 -0.04 190 14.31 346 3 10

Cycle 179 GMT 22/ 7/2020 12:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 31 14.16 497 3 3
2 12 1109.48 14 8.15 1909 3 3
3 12 1989.56 130 5.14 3205 3 3
4 12 1989.20 50 6.55 3195 3 3
5 7 1983.24 26 10.31 3255 3 3
6 13 1857.96 38 11.79 3111 3 3
7 13 1121.84 38 12.84 2027 3 3
8 13 83.40 38 14.10 469 3 3
9 8 0.00 190 14.30 346 3 10

Cycle 178 GMT 12/ 7/2020 11:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 30 14.19 508 3 3
2 12 1130.84 14 7.83 1958 3 3
3 12 2002.84 130 5.14 3297 3 3
4 12 2002.88 50 6.79 3208 3 3
5 7 1996.96 26 10.31 3263 3 3
6 13 1875.20 38 11.79 3134 3 3
7 13 991.28 38 12.97 1844 3 3
8 13 83.64 38 14.10 470 3 3
9 8 0.08 190 14.30 346 3 12

Cycle 177 GMT 2/ 7/2020 9:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 31 14.18 498 3 3
2 3 970.36 -1 14.18 498 3 3
3 3 1030.48 1 11.18 1885 3 3
4 12 1147.72 14 8.11 1956 3 3
5 12 1996.12 130 5.09 3303 3 3
6 12 1996.36 50 6.67 3194 3 3
7 7 1990.64 26 10.37 3270 3 3
8 13 1870.96 38 11.84 3107 3 3
9 13 1124.08 38 12.84 2040 3 3
10 13 86.36 38 14.11 471 3 3
11 8 -0.16 190 14.32 339 3 11

Cycle 176 GMT 22/ 6/2020 8:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 31 14.23 490 3 3
2 3 963.20 -1 14.23 490 3 3
3 3 1039.72 1 11.38 1893 3 3
4 12 1151.48 15 8.41 1982 3 3
5 12 1975.00 100 5.26 3273 3 3
6 12 1972.80 50 6.33 3191 3 3
7 7 1965.60 26 10.27 3222 3 3
8 13 1707.96 38 12.08 2877 3 3
9 13 972.92 38 13.02 1813 3 3
10 13 79.24 38 14.11 464 3 3
11 8 0.24 190 14.32 342 3 12

Cycle 175 GMT 12/ 6/2020 6:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 31 14.18 501 3 3
2 12 1120.44 15 8.49 1922 3 3
3 12 1969.60 100 5.13 3257 3 3
4 12 1969.64 50 5.70 3311 3 3
5 7 1966.32 26 10.25 3220 3 3
6 13 1867.28 38 11.77 3102 3 3
7 13 1305.08 38 12.67 2295 3 3
8 13 217.56 38 13.89 678 3 3
9 13 13.64 38 14.25 359 3 3
10 8 -0.16 190 14.33 347 3 40

Cycle 174 GMT 2/ 6/2020 5:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 14.22 488 3 3
2 12 1117.76 15 8.24 1945 3 3
3 12 1975.52 100 5.10 3258 3 3
4 12 1974.52 50 5.55 3363 3 3
5 7 1970.92 26 10.28 3249 3 3
6 13 1854.36 38 11.80 3104 3 3
7 13 1261.76 38 12.73 2239 3 3
8 13 339.64 38 13.72 881 3 3
9 8 0.12 190 14.32 343 3 9

Cycle 173 GMT 23/ 5/2020 3:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 31 14.25 502 3 3
2 12 1125.76 16 8.22 1938 3 3
3 12 1971.60 100 5.11 3220 3 3
4 12 1970.92 43 5.58 3347 3 3
5 7 1968.00 26 10.32 3240 3 3
6 13 1856.96 37 11.81 3101 3 3
7 13 1417.80 37 12.57 2480 3 3
8 13 227.80 37 13.89 697 3 3
9 8 0.16 190 14.34 341 3 8

Cycle 172 GMT 13/ 5/2020 2: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 14.20 494 3 3
2 12 1119.24 16 8.49 1923 3 3
3 12 1956.64 100 5.30 3245 3 3
4 12 1954.40 43 6.32 3161 3 3
5 7 1947.96 26 10.30 3215 3 3
6 13 1815.08 37 11.88 3029 3 3
7 13 1064.08 37 12.92 1937 3 3
8 13 125.16 37 14.06 533 3 3
9 8 -0.08 190 14.34 341 3 11

Cycle 171 GMT 3/ 5/2020 0:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 31 14.23 487 3 3
2 12 1102.44 16 8.25 1900 3 3
3 12 1961.36 100 5.07 3177 3 3
4 12 1960.92 43 5.35 3328 3 3
5 7 1958.68 26 10.31 3236 3 3
6 13 1859.12 37 11.85 3083 3 3
7 13 1301.00 37 12.72 2267 3 3
8 13 265.92 37 13.83 762 3 3
9 8 -0.04 190 14.35 339 3 8

Cycle 170 GMT 22/ 4/2020 23: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 14.27 491 3 3
2 12 1130.32 17 7.86 1945 3 3
3 12 1963.64 100 5.05 3194 3 3
4 12 1963.44 28 5.42 3352 3 3
5 7 1961.84 26 10.33 3240 3 3
6 13 1866.40 37 11.86 3117 3 3
7 13 1309.52 37 12.70 2308 3 3
8 13 390.04 37 13.67 967 3 3
9 8 0.08 190 14.33 348 3 7

Cycle 169 GMT 12/ 4/2020 21:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 31 14.30 469 3 3
2 12 1118.56 17 8.51 1919 3 3
3 12 1956.72 100 5.12 3315 3 3
4 12 1956.28 28 6.58 3143 3 3
5 7 1952.60 26 10.45 3206 3 3
6 13 1836.32 37 11.93 3074 3 3
7 13 1108.64 37 12.92 2011 3 3
8 13 179.40 37 13.99 630 3 3
9 8 0.12 190 14.36 338 3 7

Cycle 168 GMT 2/ 4/2020 20: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 14.30 495 3 3
2 12 1131.12 17 7.95 1956 3 3
3 12 1963.96 100 5.10 3214 3 3
4 12 1963.60 28 5.46 3332 3 3
5 7 1961.60 26 10.44 3238 3 3
6 13 1862.84 37 11.98 3115 3 3
7 13 1428.96 37 12.66 2481 2 3
8 13 356.08 37 13.73 905 3 3
9 8 -0.08 190 14.37 331 3 6

Cycle 167 GMT 23/ 3/2020 18:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 31 14.32 494 3 3
2 12 1119.32 17 8.09 1922 3 3
3 12 1962.24 75 5.15 3222 3 3
4 12 1962.32 28 5.24 3391 3 3
5 7 1960.96 26 10.45 3238 3 3
6 13 1865.64 37 12.00 3110 3 3
7 13 1178.96 37 12.89 2107 2 3
8 13 293.56 37 13.82 808 3 3
9 13 5.00 37 14.31 345 3 3
10 8 0.08 190 14.37 341 3 32

Cycle 166 GMT 13/ 3/2020 16:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 14.31 495 3 3
2 3 1018.88 1 11.11 1876 3 3
3 12 1141.76 17 7.92 1964 3 3
4 12 1994.40 75 5.08 3263 2 3
5 12 1994.16 28 5.20 3440 3 3
6 7 1993.16 26 10.47 3273 3 3
7 13 1898.64 37 12.05 3141 2 3
8 13 1620.64 37 12.52 2766 2 3
9 13 518.76 37 13.57 1153 3 3
10 13 29.32 37 14.28 389 3 3
11 8 0.08 190 14.38 340 3 22

Cycle 165 GMT 3/ 3/2020 15:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 14.33 479 3 3
2 12 1115.72 17 7.52 1898 3 3
3 12 1998.76 75 5.03 3063 3 3
4 12 1999.00 28 5.06 3259 3 3
5 7 1998.96 26 10.36 3298 3 3
6 13 1915.96 37 12.00 3184 3 3
7 13 1512.20 37 12.60 2610 3 3
8 13 454.48 37 13.64 1052 3 3
9 13 22.32 37 14.29 377 3 3
10 8 -0.12 190 14.38 343 3 19

Cycle 164 GMT 22/ 2/2020 13:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 14.30 479 3 3
2 3 954.16 -1 14.30 479 3 3
3 3 1025.84 1 11.15 1881 3 3
4 12 1145.28 17 7.72 1964 3 3
5 12 2002.20 50 5.16 3234 3 3
6 12 2002.72 28 5.12 3374 3 3
7 7 2002.92 26 10.42 3288 3 3
8 13 1902.16 37 12.05 3168 3 3
9 13 1479.12 37 12.63 2567 3 3
10 13 428.64 37 13.67 1012 3 3
11 13 21.48 37 14.31 368 3 3
12 8 0.04 190 14.38 342 3 23

Cycle 163 GMT 12/ 2/2020 13:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 31 14.29 499 3 3
2 12 1117.52 17 7.80 1905 3 3
3 12 2002.56 50 5.08 3231 2 3
4 12 2003.40 28 5.09 3378 3 3
5 7 2003.96 26 10.45 3291 3 3
6 13 1919.08 37 12.00 3197 2 3
7 13 1360.72 37 12.76 2371 2 3
8 13 457.80 37 13.65 1062 3 3
9 13 7.12 37 14.33 346 3 3
10 8 0.04 190 14.38 341 3 26

Cycle 162 GMT 2/ 2/2020 12:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 31 14.31 492 3 3
2 12 1120.80 17 7.90 1925 3 3
3 12 2002.16 50 5.09 3303 2 3
4 12 2003.00 28 5.31 3427 3 3
5 7 2002.96 26 10.60 3295 3 3
6 13 1909.84 37 12.10 3192 2 3
7 13 1355.32 37 12.77 2388 2 3
8 13 451.04 37 13.65 1057 3 3
9 8 -0.08 190 14.36 341 3 6

Cycle 161 GMT 23/ 1/2020 11:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 31 14.31 493 3 3
2 12 1116.36 17 7.03 1919 3 3
3 12 2001.72 50 5.10 3199 3 3
4 12 2002.96 28 5.06 3381 3 3
5 7 2004.60 26 10.55 3286 3 3
6 13 1916.24 37 12.14 3195 2 3
7 13 1500.96 37 12.68 2583 3 3
8 13 467.56 37 13.65 1077 3 3
9 13 10.72 37 14.34 353 3 3
10 8 -0.04 190 14.38 343 3 20

Cycle 160 GMT 13/ 1/2020 11:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 31 14.30 501 3 3
2 12 1119.32 15 7.04 1893 3 3
3 12 2001.56 65 5.12 3332 2 3
4 7 2005.40 26 10.54 3301 3 3
5 13 1919.36 37 12.11 3178 2 3
6 13 1499.84 37 12.66 2557 2 3
7 13 576.20 37 13.54 1238 3 3
8 8 0.12 190 14.38 337 3 4

Cycle 159 GMT 3/ 1/2020 11:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 30 14.29 509 3 3
2 3 1025.08 1 11.78 1885 3 3
3 12 1130.60 15 7.17 1938 3 3
4 12 2006.96 65 6.01 3274 2 3
5 7 2006.80 26 10.56 3288 3 3
6 13 1891.52 37 12.16 3135 3 3
7 13 1181.32 37 12.94 2117 3 3
8 13 266.68 37 13.94 760 3 3
9 8 -0.12 190 14.37 340 3 6

Cycle 158 GMT 24/12/2019 11: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 31 14.33 492 3 3
2 3 954.00 -1 14.33 492 3 3
3 3 1022.08 1 11.15 1878 3 3
4 12 1145.92 15 7.13 1932 3 3
5 12 2002.08 65 6.30 3219 3 3
6 7 1999.56 26 10.64 3279 3 3
7 13 1879.84 37 12.16 3141 3 3
8 13 1150.00 37 12.98 2066 3 3
9 13 226.24 37 14.00 698 3 3
10 8 0.16 190 14.37 343 3 6

Cycle 157 GMT 14/12/2019 11:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 14.32 497 3 3
2 12 1106.68 15 7.18 1913 3 3
3 12 2002.40 65 6.06 3247 3 3
4 7 2000.60 26 10.66 3300 3 3
5 13 1886.36 37 12.13 3181 3 3
6 13 1292.52 37 12.84 2287 3 3
7 13 220.40 37 14.02 686 3 3
8 8 0.08 190 14.39 339 3 6

Cycle 156 GMT 4/12/2019 11: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 30 14.30 501 3 3
2 12 1125.12 15 7.46 1909 3 3
3 12 2001.32 65 6.76 3212 2 3
4 7 1997.48 26 10.69 3275 3 3
5 13 1868.60 37 12.19 3135 3 3
6 13 959.24 37 13.14 1796 3 3
7 13 88.20 37 14.25 472 3 3
8 8 0.08 190 14.39 340 3 12

Cycle 155 GMT 24/11/2019 11: 5: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 14.26 501 3 3
2 12 1127.88 15 7.10 1932 3 3
3 12 2002.44 60 6.66 3208 3 3
4 7 1999.20 26 10.73 3269 3 3
5 13 1865.32 37 12.17 3123 3 3
6 13 1085.28 37 13.04 1961 3 3
7 13 156.64 37 14.12 580 3 3
8 8 -0.08 190 14.38 340 3 10

Cycle 154 GMT 14/11/2019 11: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 14.31 493 3 3
2 12 1130.04 15 7.67 1943 3 3
3 12 2000.36 60 7.19 3201 3 3
4 7 1996.32 26 10.75 3275 3 3
5 13 1863.24 37 12.15 3134 2 3
6 13 1090.84 37 13.01 1988 3 3
7 13 130.28 37 14.16 540 3 3
8 8 0.16 190 14.37 343 3 13

Cycle 153 GMT 4/11/2019 11:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 30 14.31 504 3 3
2 12 1128.20 15 7.82 1927 3 3
3 12 2001.24 60 7.35 3215 2 3
4 7 1995.60 26 10.72 3317 3 3
5 13 1852.44 37 12.13 3128 2 3
6 13 1061.40 37 13.04 1945 3 3
7 13 133.00 37 14.15 554 3 3
8 13 22.36 37 14.35 375 3 3
9 8 -0.16 190 14.37 341 3 65

Cycle 152 GMT 25/10/2019 11:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 30 14.28 499 3 3
2 12 1111.80 15 7.76 1927 3 3
3 12 2001.96 60 7.55 3204 2 3
4 7 1995.72 26 10.77 3295 3 3
5 13 1714.76 37 12.35 2906 2 3
6 13 1063.92 37 13.04 1947 3 3
7 13 110.64 37 14.17 520 3 3
8 8 0.04 190 14.36 343 3 11

Cycle 151 GMT 15/10/2019 11: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 30 14.29 510 3 3
2 12 1116.04 15 8.16 1939 3 3
3 12 2001.60 60 7.96 3218 3 3
4 7 1996.64 26 10.81 3262 3 3
5 13 1853.28 37 12.21 3081 3 3
6 13 1049.88 37 13.04 1926 2 3
7 13 86.00 37 14.21 481 3 3
8 8 0.08 190 14.34 347 3 13

Cycle 150 GMT 5/10/2019 11: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 30 14.29 498 3 3
2 12 1107.24 12 7.56 1904 3 3
3 12 2005.08 59 7.85 3220 2 3
4 7 2000.44 26 10.86 3287 3 3
5 13 1860.36 37 12.17 3113 3 3
6 13 1056.36 37 13.04 1938 3 3
7 13 113.56 37 14.18 525 3 3
8 8 -0.04 190 14.34 349 3 12

Cycle 149 GMT 25/ 9/2019 11:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 14.30 497 3 3
2 12 1110.72 12 7.81 1918 3 3
3 12 2003.88 59 8.31 3219 2 3
4 7 1999.08 26 10.84 3296 3 3
5 13 1852.56 37 12.17 3098 2 3
6 13 1048.12 37 13.04 1915 3 3
7 13 48.60 37 14.29 417 3 3
8 8 0.00 190 14.35 348 3 14

Cycle 148 GMT 15/ 9/2019 11:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 14.28 500 3 3
2 12 1111.40 12 8.10 1909 3 3
3 12 2005.80 59 8.50 3213 3 3
4 7 2000.48 26 10.85 3276 3 3
5 13 1719.04 37 12.32 2890 2 3
6 13 774.16 37 13.30 1540 2 3
7 13 26.84 37 14.34 376 3 3
8 8 0.04 190 14.35 345 3 16

Cycle 147 GMT 5/ 9/2019 11:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 30 14.31 498 3 3
2 12 1130.52 11 8.23 1953 3 3
3 12 2002.96 57 8.85 3227 2 3
4 7 1997.84 26 10.86 3276 3 3
5 13 1857.48 30 12.30 3129 2 3
6 13 1216.68 30 12.97 2165 2 3
7 13 238.04 30 13.99 718 3 3
8 8 0.08 190 14.33 345 3 5

Cycle 146 GMT 26/ 8/2019 12:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 30 14.25 502 3 3
2 12 1139.56 11 8.28 1987 3 3
3 12 2002.96 57 8.94 3225 3 3
4 7 1997.08 26 10.84 3301 3 3
5 13 1706.00 30 12.46 2888 2 3
6 13 928.68 30 13.22 1758 3 3
7 13 146.76 30 14.13 569 3 3
8 8 0.04 190 14.35 342 3 7

Cycle 145 GMT 16/ 8/2019 12:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 30 14.28 504 3 3
2 12 1130.96 11 8.78 1978 3 3
3 12 2001.88 57 9.07 3223 2 3
4 7 1996.28 26 10.88 3283 3 3
5 13 1851.60 30 12.32 3104 2 3
6 13 1200.96 30 12.97 2144 3 3
7 13 222.00 30 14.02 694 3 3
8 8 0.20 190 14.33 342 3 6

Cycle 144 GMT 6/ 8/2019 12:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 30 14.27 504 3 3
2 3 970.76 -1 14.27 504 3 3
3 3 1046.64 1 12.15 1913 3 3
4 12 1142.88 11 9.29 2000 3 3
5 12 2000.40 57 9.38 3248 3 3
6 7 1993.44 26 10.89 3296 3 3
7 13 1698.88 30 12.47 2872 3 3
8 13 1068.68 30 13.09 1938 3 3
9 13 223.40 30 14.01 683 3 3
10 8 -0.04 190 14.32 340 3 6

Cycle 143 GMT 27/ 7/2019 12:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 14.30 501 3 3
2 3 971.36 -1 14.30 501 3 3
3 3 1048.80 1 12.08 1932 3 3
4 12 1141.92 9 9.27 1995 3 3
5 12 2002.12 53 9.53 3220 3 3
6 7 1997.72 26 10.93 3261 3 3
7 13 1857.28 30 12.32 3107 2 3
8 13 918.36 30 13.21 1737 2 3
9 13 125.40 30 14.14 537 3 3
10 8 0.04 190 14.30 342 3 9

Cycle 142 GMT 17/ 7/2019 13:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 30 14.27 498 3 3
2 12 1103.96 9 9.34 1938 3 3
3 12 2003.04 53 9.33 3218 2 3
4 7 1996.76 26 10.91 3279 3 3
5 13 1697.76 30 12.45 2888 2 3
6 13 924.04 30 13.21 1745 3 3
7 13 135.64 30 14.12 563 3 3
8 13 4.56 30 14.36 354 3 3
9 8 -0.04 190 14.30 347 3 26

Cycle 141 GMT 7/ 7/2019 13: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 30 14.25 500 3 3
2 12 1120.76 9 9.34 1962 3 3
3 12 2005.12 53 9.45 3243 2 3
4 7 1999.52 26 10.92 3306 3 3
5 13 1707.48 30 12.44 2888 3 3
6 13 1072.84 30 13.07 1955 3 3
7 13 130.00 30 14.14 546 3 3
8 8 0.16 190 14.30 341 3 11

Cycle 140 GMT 27/ 6/2019 13:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 30 14.29 502 3 3
2 12 1104.08 9 9.79 1940 3 3
3 12 2002.88 53 9.52 3233 3 3
4 7 1996.48 26 10.91 3281 3 3
5 13 1555.32 30 12.58 2664 3 3
6 13 1079.28 30 13.06 1975 3 3
7 13 119.16 30 14.15 536 3 3
8 8 -0.04 190 14.31 341 3 7

Cycle 139 GMT 17/ 6/2019 13:11: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 30 14.24 508 3 3
2 12 1129.76 9 10.16 1979 3 3
3 12 2000.44 53 9.83 3228 2 3
4 7 1994.16 26 10.93 3295 3 3
5 13 1402.44 30 12.73 2446 2 3
6 13 793.80 30 13.34 1537 2 3
7 13 139.40 30 14.11 562 3 3
8 8 0.08 190 14.28 347 3 8

Cycle 138 GMT 7/ 6/2019 13:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 30 14.28 514 3 3
2 12 1127.08 9 10.60 1985 3 3
3 12 2001.96 52 9.91 3236 3 3
4 7 1994.08 26 10.93 3303 3 3
5 13 1690.12 42 12.21 2870 3 3
6 13 535.88 42 13.53 1178 3 3
7 8 -0.04 190 14.27 349 3 7

Cycle 137 GMT 28/ 5/2019 13:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 14.28 504 3 3
2 12 1123.24 9 10.26 1986 3 3
3 12 2000.76 52 9.86 3221 3 3
4 7 1993.64 26 10.95 3309 3 3
5 13 1693.72 42 12.22 2848 2 3
6 13 848.68 42 13.16 1631 3 3
7 13 27.52 42 14.30 385 3 3
8 8 0.08 190 14.29 348 3 33

Cycle 136 GMT 18/ 5/2019 13:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 30 14.32 502 3 3
2 12 1132.68 8 10.35 2001 3 3
3 12 2002.64 52 9.91 3236 2 3
4 7 1995.88 26 10.97 3264 3 3
5 13 1502.44 42 12.42 2578 3 3
6 13 677.88 42 13.35 1392 3 3
7 13 26.04 42 14.30 388 3 3
8 8 0.00 190 14.28 350 3 47

Cycle 135 GMT 8/ 5/2019 13:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 14.34 483 3 3
2 12 1106.68 8 10.50 1950 3 3
3 12 2000.84 52 9.90 3231 3 3
4 7 1993.96 26 10.94 3261 3 3
5 13 1508.00 42 12.42 2584 3 3
6 13 445.36 42 13.63 1039 3 3
7 8 -0.08 190 14.29 344 3 9

Cycle 134 GMT 28/ 4/2019 13:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 30 14.33 497 3 3
2 12 1127.20 8 10.72 2005 3 3
3 12 2002.56 52 9.96 3235 3 3
4 7 1996.08 26 10.98 3259 3 3
5 13 1512.52 42 12.41 2595 3 3
6 13 445.96 42 13.63 1040 3 3
7 13 13.36 42 14.33 364 3 3
8 8 0.00 190 14.27 345 3 47

Cycle 133 GMT 18/ 4/2019 13: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 30 14.33 485 3 3
2 12 1114.32 8 11.06 1965 3 3
3 12 2003.04 49 10.03 3239 3 3
4 7 1996.68 26 10.99 3284 3 3
5 13 1532.08 43 12.39 2624 3 3
6 13 468.36 43 13.60 1072 3 3
7 8 -0.04 190 14.28 345 3 11

Cycle 132 GMT 8/ 4/2019 12:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 14.32 502 3 3
2 12 1120.60 8 11.25 1994 3 3
3 12 2002.76 49 10.01 3252 3 3
4 7 1996.08 26 11.00 3284 3 3
5 13 1755.84 43 12.15 2943 2 3
6 13 416.48 43 13.67 993 3 3
7 8 0.04 190 14.29 342 3 9

Cycle 131 GMT 29/ 3/2019 12:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 30 14.36 491 3 3
2 12 1105.68 7 10.94 1980 3 3
3 12 2003.52 47 10.05 3224 3 3
4 7 1997.84 26 10.93 3281 3 3
5 13 1759.24 43 12.14 2954 3 3
6 13 669.24 43 13.37 1370 3 3
7 8 -0.04 190 14.29 342 3 5

Cycle 130 GMT 19/ 3/2019 12: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 14.33 495 3 3
2 12 1118.32 7 11.18 1996 3 3
3 12 2001.80 47 10.16 3241 3 3
4 7 1996.76 26 10.93 3302 3 3
5 13 1766.04 43 12.13 2977 3 3
6 13 684.92 43 13.34 1406 3 3
7 13 29.04 43 14.31 384 3 3
8 8 -0.04 190 14.28 346 3 38

Cycle 129 GMT 9/ 3/2019 11:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 30 14.32 492 3 3
2 12 1114.40 7 11.38 1989 3 3
3 12 2002.68 47 10.14 3243 2 3
4 7 1996.96 26 10.96 3264 3 3
5 13 1525.28 43 12.42 2573 2 3
6 13 461.24 43 13.60 1064 3 3
7 13 24.88 43 14.29 383 3 3
8 8 0.04 190 14.26 345 3 49

Cycle 128 GMT 27/ 2/2019 11:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 14.31 496 3 3
2 12 1136.24 7 11.61 2024 3 3
3 12 2003.28 47 10.18 3254 3 3
4 7 1996.20 26 10.92 3268 3 3
5 13 1505.04 43 12.40 2590 3 3
6 13 446.28 43 13.63 1041 3 3
7 13 22.28 43 14.30 375 3 3
8 8 0.04 190 14.22 348 3 49

Cycle 127 GMT 17/ 2/2019 10:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 30 14.33 496 3 3
2 12 1133.92 7 11.60 2027 3 3
3 12 2001.24 47 10.26 3266 3 3
4 7 1995.32 26 10.95 3295 3 3
5 13 1526.32 43 12.40 2597 3 3
6 13 459.84 43 13.61 1060 3 3
7 8 0.00 190 14.27 344 3 6

Cycle 126 GMT 7/ 2/2019 10:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 14.33 491 3 3
2 12 1115.12 7 11.62 1986 3 3
3 12 2001.76 42 10.26 3255 2 3
4 7 1995.80 26 10.95 3317 3 3
5 13 1754.20 43 12.12 2968 2 3
6 13 676.16 43 13.33 1396 3 3
7 13 12.64 43 14.32 364 3 3
8 8 -0.20 190 14.24 347 3 35

Cycle 125 GMT 28/ 1/2019 10:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 30 14.31 508 3 3
2 12 1127.00 7 11.57 2013 3 3
3 12 2017.00 42 10.27 3273 2 3
4 7 2011.72 26 10.98 3292 3 3
5 13 1780.88 43 12.14 2935 3 3
6 13 713.84 43 13.32 1412 3 3
7 13 20.36 43 14.32 365 3 3
8 8 -0.08 190 14.22 347 3 38

Cycle 124 GMT 18/ 1/2019 9:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 30 14.32 491 3 3
2 12 1133.00 7 11.58 2016 3 3
3 12 2000.80 42 10.30 3260 2 3
4 7 1994.72 26 10.99 3261 3 3
5 13 1762.32 43 12.14 2919 2 3
6 13 663.48 43 13.36 1364 2 3
7 8 0.24 190 14.26 347 3 6

Cycle 123 GMT 8/ 1/2019 9:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 30 14.31 502 3 3
2 12 1130.20 7 11.69 2017 3 3
3 12 2003.52 39 10.34 3282 2 3
4 7 1999.36 26 10.98 3263 3 3
5 13 1766.52 43 12.14 2918 2 3
6 13 691.32 43 13.31 1416 3 3
7 13 16.32 43 14.32 366 3 3
8 8 -0.04 190 14.23 349 3 32

Cycle 122 GMT 29/12/2018 9:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 30 14.35 496 3 3
2 12 1115.00 7 11.68 1989 3 3
3 12 2000.88 39 10.32 3270 2 3
4 7 1995.32 26 10.93 3308 3 3
5 13 1752.16 43 12.11 2945 2 3
6 13 689.12 43 13.32 1412 3 3
7 13 15.64 43 14.32 370 3 3
8 8 -0.16 190 14.21 348 3 36

Cycle 121 GMT 19/12/2018 8:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 30 14.33 495 3 3
2 12 1138.84 7 11.64 2024 3 3
3 12 2002.80 39 10.43 3283 2 3
4 7 1997.20 26 10.98 3259 3 3
5 13 1524.40 43 12.41 2548 2 3
6 13 500.52 43 13.56 1110 3 3
7 8 0.00 190 14.26 341 3 4

Cycle 120 GMT 9/12/2018 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 30 14.29 500 3 3
2 12 1120.44 7 11.68 2011 3 3
3 12 2003.16 39 10.55 3277 3 3
4 7 1998.00 26 10.97 3299 3 3
5 13 1760.52 43 12.09 2961 2 3
6 13 693.20 43 13.30 1421 3 3
7 8 0.08 190 14.24 346 3 5

Cycle 119 GMT 29/11/2018 7:30:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 30 14.29 491 3 3
2 12 1132.00 7 11.69 2010 3 3
3 12 2003.04 39 10.43 3293 2 3
4 7 1997.88 26 10.98 3266 3 3
5 13 1522.20 43 12.37 2580 3 3
6 13 508.80 43 13.53 1136 3 3
7 8 0.04 190 14.24 345 3 7

Cycle 118 GMT 19/11/2018 6:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 30 14.31 507 3 3
2 12 1125.92 7 11.70 2012 3 3
3 12 2006.48 39 10.49 3271 2 3
4 7 2000.84 26 10.96 3277 3 3
5 13 1521.72 43 12.39 2546 2 3
6 13 704.20 43 13.29 1435 3 3
7 8 -0.04 190 14.24 344 3 8

Cycle 117 GMT 9/11/2018 5:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 30 14.28 509 3 3
2 12 1108.12 7 11.76 1999 3 3
3 12 2001.88 39 10.45 3302 2 3
4 7 1996.40 26 10.93 3259 3 3
5 13 1781.88 43 12.05 3000 2 3
6 13 707.76 43 13.27 1442 2 3
7 8 -0.04 190 14.22 350 3 5

Cycle 116 GMT 30/10/2018 5: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 30 14.33 489 3 3
2 12 1109.68 7 11.65 1984 3 3
3 12 2002.72 39 10.46 3274 2 3
4 7 1997.60 26 10.96 3256 3 3
5 13 1534.96 43 12.38 2563 3 3
6 13 500.48 43 13.54 1124 3 3
7 8 0.08 190 14.24 346 3 11

Cycle 115 GMT 20/10/2018 4:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 30 14.28 492 3 3
2 3 967.28 -1 14.28 492 3 3
3 3 1036.40 1 11.69 1909 3 3
4 12 1155.36 7 11.71 2074 3 3
5 12 2000.64 39 10.67 3272 2 3
6 7 1995.84 26 11.00 3249 3 3
7 13 1535.32 43 12.34 2604 3 3
8 13 725.24 43 13.28 1432 3 3
9 8 0.08 190 14.26 338 3 6

Cycle 114 GMT 10/10/2018 4:39:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 30 14.30 499 3 3
2 12 1142.04 7 11.73 2018 3 3
3 12 1995.16 39 10.58 3256 3 3
4 7 1989.44 26 10.91 3234 3 3
5 13 1753.72 43 12.06 2918 2 3
6 13 658.68 43 13.36 1327 3 3
7 8 0.12 190 14.25 340 3 8

Cycle 113 GMT 30/ 9/2018 3:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 14.36 484 3 3
2 3 961.44 -1 14.36 484 3 3
3 3 1034.80 1 11.66 1880 3 3
4 12 1144.12 7 11.51 2047 3 3
5 12 2000.44 39 10.50 3250 3 3
6 7 1995.52 26 10.84 3261 3 3
7 13 1533.92 43 12.33 2571 3 3
8 13 502.68 43 13.53 1118 3 3
9 8 -0.04 190 14.26 341 3 7

Cycle 112 GMT 20/ 9/2018 3:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 30 14.35 501 3 3
2 12 1113.60 6 11.42 2003 3 3
3 7 2003.48 57 10.16 3256 3 3
4 13 1614.56 43 12.19 2716 3 3
5 13 483.84 43 13.55 1101 3 3
6 8 0.12 190 14.27 342 3 4

Cycle 111 GMT 10/ 9/2018 2: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 30 14.35 493 3 3
2 12 1109.92 6 11.53 1980 3 3
3 7 2006.04 57 10.26 3262 3 3
4 13 1435.40 43 12.41 2448 3 3
5 13 522.28 43 13.53 1132 3 3
6 8 -0.16 190 14.27 337 3 8

Cycle 110 GMT 31/ 8/2018 1:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 14.36 486 3 3
2 12 1112.84 6 11.51 2000 3 3
3 7 2001.28 56 10.27 3248 3 3
4 13 1578.24 43 12.25 2659 3 3
5 13 635.68 43 13.37 1324 3 3
6 8 0.32 190 14.26 340 3 5

Cycle 109 GMT 21/ 8/2018 0:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 30 14.30 501 3 3
2 12 1125.44 6 11.57 2022 3 3
3 7 2004.12 56 10.37 3258 3 3
4 13 1413.76 43 12.45 2411 2 3
5 13 494.92 43 13.58 1073 3 3
6 8 0.04 190 14.27 335 3 6

Cycle 108 GMT 10/ 8/2018 23:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 30 14.34 493 3 3
2 12 1091.76 5 11.42 1965 3 3
3 7 2002.12 56 10.34 3251 3 3
4 13 1801.08 44 11.96 3002 3 3
5 13 617.92 44 13.39 1295 3 3
6 8 0.04 190 14.27 338 3 5

Cycle 107 GMT 31/ 7/2018 23:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 30 14.31 500 3 3
2 12 1122.84 5 11.51 2001 3 3
3 7 2002.28 56 10.39 3255 3 3
4 13 1414.92 44 12.41 2414 3 3
5 13 516.44 44 13.54 1105 3 3
6 8 0.04 190 14.29 329 3 6

Cycle 106 GMT 21/ 7/2018 22:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 30 14.33 502 3 3
2 12 1105.48 5 11.51 1975 3 3
3 7 2001.80 56 10.42 3259 3 3
4 13 1587.52 44 12.26 2645 3 3
5 13 432.44 44 13.63 1019 3 3
6 8 0.04 190 14.26 341 3 9

Cycle 105 GMT 11/ 7/2018 21:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 30 14.34 506 3 3
2 12 1130.20 5 11.44 2027 3 3
3 7 2005.16 56 10.48 3258 3 3
4 13 1445.40 44 12.42 2433 3 3
5 13 523.68 44 13.53 1119 3 3
6 8 0.08 190 14.25 341 3 7

Cycle 104 GMT 1/ 7/2018 20:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 30 14.35 504 3 3
2 12 1117.00 5 11.45 2000 3 3
3 7 2001.28 56 10.49 3252 3 3
4 13 1592.60 44 12.28 2638 3 3
5 13 442.44 44 13.66 994 3 3
6 8 0.00 190 14.26 341 3 5

Cycle 103 GMT 21/ 6/2018 20:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 30 14.37 503 3 3
2 12 1119.88 5 11.62 2009 3 3
3 7 2002.80 56 10.61 3255 3 3
4 13 1399.96 44 12.47 2404 3 3
5 13 472.76 44 13.58 1075 3 3
6 8 0.08 190 14.26 342 3 6

Cycle 102 GMT 11/ 6/2018 19:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 30 14.39 498 3 3
2 12 1111.72 5 11.72 1998 3 3
3 7 2003.12 55 10.67 3253 3 3
4 13 1787.04 43 12.11 2932 2 3
5 13 794.12 43 13.25 1506 2 3
6 8 0.12 190 14.29 339 3 6

Cycle 101 GMT 1/ 6/2018 19:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 30 14.40 498 3 3
2 12 1123.44 5 11.69 2017 3 3
3 7 2002.24 56 10.66 3256 3 3
4 13 1786.88 43 12.10 2953 3 3
5 13 775.96 43 13.27 1488 3 3
6 13 3.24 43 14.41 339 3 3
7 8 0.04 190 14.24 344 3 24

Cycle 100 GMT 22/ 5/2018 19:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 30 14.40 489 3 3
2 12 1124.52 5 11.72 2020 3 3
3 7 2004.32 56 10.68 3267 3 3
4 13 1617.32 43 12.31 2713 2 3
5 13 638.72 43 13.42 1331 3 3
6 8 0.08 190 14.28 333 3 6

Cycle 99 GMT 12/ 5/2018 18:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 14.41 498 3 3
2 12 1107.56 5 11.77 1986 3 3
3 7 2006.12 55 10.73 3272 3 3
4 13 1803.84 43 12.14 2970 2 3
5 13 795.92 43 13.23 1565 3 3
6 8 0.16 190 14.30 339 3 6

Cycle 98 GMT 2/ 5/2018 18:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 30 14.43 502 3 3
2 12 1122.92 4 11.55 2001 3 3
3 7 2005.24 54 10.79 3270 3 3
4 13 1783.60 42 12.18 2977 3 3
5 13 802.16 42 13.24 1567 3 3
6 13 50.44 42 14.30 417 3 3
7 8 0.04 190 14.27 342 3 21

Cycle 97 GMT 22/ 4/2018 18:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 30 14.42 495 3 3
2 12 1126.36 4 11.60 2004 3 3
3 7 2006.16 54 10.88 3258 3 3
4 13 1586.04 42 12.40 2666 2 3
5 13 829.04 42 13.23 1599 3 3
6 13 44.04 42 14.31 410 3 3
7 8 -0.08 190 14.25 344 3 25

Cycle 96 GMT 12/ 4/2018 18:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 30 14.45 495 3 3
2 7 2006.64 52 10.63 3258 3 3
3 13 1812.20 34 12.37 3012 2 3
4 13 907.68 34 13.24 1715 3 3
5 13 93.36 34 14.27 486 3 3
6 8 0.00 190 14.31 338 3 11

Cycle 95 GMT 2/ 4/2018 18:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 30 14.40 501 3 3
2 7 2007.80 52 10.78 3260 3 3
3 13 1624.44 34 12.58 2746 2 3
4 13 772.80 34 13.39 1520 3 3
5 13 64.88 34 14.32 444 3 3
6 8 0.04 190 14.31 340 3 7

Cycle 94 GMT 23/ 3/2018 17:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 14.44 489 3 3
2 7 2005.84 51 10.73 3269 3 3
3 13 1807.04 34 12.39 3033 3 3
4 13 896.20 34 13.26 1708 3 3
5 13 85.68 34 14.27 486 3 3
6 8 0.08 190 14.28 349 3 10

Cycle 93 GMT 13/ 3/2018 17:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 30 14.43 497 3 3
2 3 969.96 -1 14.43 497 3 3
3 3 1044.28 1 12.25 1932 3 3
4 7 2004.92 52 10.91 3263 3 3
5 13 1823.32 34 12.42 3026 3 3
6 13 915.24 34 13.24 1738 3 3
7 13 83.60 34 14.27 480 3 3
8 8 0.04 190 14.29 344 3 9

Cycle 92 GMT 3/ 3/2018 17:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 14.44 497 3 3
2 7 2003.56 51 10.74 3246 3 3
3 13 1816.92 34 12.40 3016 3 3
4 13 926.28 34 13.25 1741 3 3
5 13 55.52 34 14.33 428 3 3
6 8 0.04 190 14.30 343 3 10

Cycle 91 GMT 21/ 2/2018 17: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 14.46 486 3 3
2 7 1597.36 51 11.14 2689 3 3
3 13 1418.20 34 12.72 2463 2 3
4 13 737.12 34 13.40 1479 3 3
5 13 42.68 34 14.35 405 3 3
6 8 0.24 190 14.26 346 3 12

Cycle 90 GMT 11/ 2/2018 16: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 30 14.45 486 3 3
2 7 2009.04 51 10.86 3254 3 3
3 13 1614.24 34 12.63 2737 3 3
4 13 776.80 34 13.41 1530 3 3
5 13 41.96 34 14.40 393 3 3
6 8 -0.08 190 14.32 338 3 12

Cycle 89 GMT 1/ 2/2018 15:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 14.47 495 3 3
2 7 2002.08 51 10.83 3260 3 3
3 13 1803.68 34 12.44 3028 3 3
4 13 889.56 34 13.29 1691 3 3
5 13 76.76 34 14.32 454 3 3
6 8 -0.08 190 14.32 336 3 10

Cycle 88 GMT 22/ 1/2018 15:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 30 14.43 500 3 3
2 7 2008.80 51 10.96 3243 3 3
3 13 1811.80 34 12.45 3021 3 3
4 13 895.16 34 13.29 1700 3 3
5 13 45.20 34 14.39 403 3 3
6 8 0.12 190 14.31 338 3 9

Cycle 87 GMT 12/ 1/2018 15: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 14.46 487 3 3
2 7 2006.28 51 10.82 3256 3 3
3 13 1811.64 34 12.46 3033 3 3
4 13 915.20 34 13.28 1732 3 3
5 13 90.52 34 14.30 476 3 3
6 8 0.00 190 14.32 338 3 7

Cycle 86 GMT 2/ 1/2018 14:55: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 30 14.44 512 3 3
2 7 2010.04 51 10.89 3272 3 3
3 13 1818.72 34 12.50 2998 3 3
4 13 914.64 34 13.31 1707 3 3
5 13 90.08 34 14.32 465 3 3
6 8 0.28 190 14.33 337 3 9

Cycle 85 GMT 23/12/2017 14:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 30 14.48 482 3 3
2 7 2006.16 52 10.89 3260 3 3
3 13 1816.32 34 12.49 3020 3 3
4 13 908.80 34 13.29 1726 3 3
5 13 91.92 34 14.32 480 3 3
6 8 -0.12 190 14.33 338 3 14

Cycle 84 GMT 13/12/2017 14:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 14.44 497 3 3
2 7 2007.00 52 10.76 3256 3 3
3 13 1826.80 34 12.48 3021 3 3
4 13 959.80 34 13.26 1798 2 3
5 13 57.56 34 14.37 421 3 3
6 8 0.00 190 14.30 339 3 7

Cycle 83 GMT 3/12/2017 14:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 30 14.47 495 3 3
2 7 2003.00 52 10.86 3250 3 3
3 13 1611.88 34 12.70 2696 3 3
4 13 930.88 34 13.32 1717 3 3
5 13 85.28 34 14.38 427 3 3
6 8 0.04 190 14.33 337 3 14

Cycle 82 GMT 23/11/2017 14:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 14.45 498 3 3
2 7 2001.84 51 10.84 3241 3 3
3 13 1804.68 34 12.53 2982 3 3
4 13 903.56 34 13.32 1721 3 3
5 13 77.40 34 14.35 464 3 3
6 8 0.00 190 14.31 338 3 8

Cycle 81 GMT 13/11/2017 14:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 29 14.45 494 3 3
2 7 2002.52 51 10.83 3247 3 3
3 13 1803.20 34 12.55 2981 3 3
4 13 893.60 34 13.34 1701 3 3
5 13 82.80 34 14.35 465 3 3
6 8 0.08 190 14.33 341 3 9

Cycle 80 GMT 3/11/2017 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 29 14.46 495 3 3
2 7 2005.96 51 10.69 3242 3 3
3 13 1814.16 34 12.52 3029 3 3
4 13 901.48 34 13.34 1710 3 3
5 13 92.84 34 14.34 483 3 3
6 8 0.00 190 14.31 338 3 11

Cycle 79 GMT 24/10/2017 14:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 14.50 495 3 3
2 7 2006.32 52 10.64 3271 3 3
3 13 1617.44 34 12.75 2694 3 3
4 13 770.36 34 13.48 1518 3 3
5 13 65.52 34 14.39 437 3 3
6 8 -0.04 190 14.32 342 3 10

Cycle 78 GMT 14/10/2017 14:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 29 14.49 505 3 3
2 7 2009.64 51 10.58 3271 3 3
3 13 1622.52 34 12.74 2730 3 3
4 13 774.20 34 13.50 1515 3 3
5 13 58.84 34 14.39 422 3 3
6 8 0.12 190 14.30 339 3 7

Cycle 77 GMT 4/10/2017 13:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 29 14.49 501 3 3
2 7 2002.72 51 10.57 3240 3 3
3 13 1804.20 34 12.56 3014 3 3
4 13 916.84 34 13.36 1722 3 3
5 13 86.52 34 14.33 479 3 3
6 8 0.12 190 14.31 344 3 9

Cycle 76 GMT 24/ 9/2017 13:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 14.51 494 3 3
2 3 1028.92 1 12.13 1888 3 3
3 7 2004.84 51 10.68 3270 3 3
4 13 1617.04 34 12.77 2729 2 3
5 13 937.24 34 13.36 1748 2 3
6 13 91.40 34 14.34 484 3 3
7 8 0.04 190 14.29 345 3 9

Cycle 75 GMT 14/ 9/2017 13:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 29 14.51 499 3 3
2 3 963.96 -1 14.51 499 3 3
3 3 1029.08 1 12.08 1899 3 3
4 7 2005.92 51 10.65 3258 3 3
5 13 1810.12 34 12.60 3023 2 3
6 13 903.36 34 13.38 1718 3 3
7 13 83.92 34 14.35 469 3 3
8 8 -0.08 190 14.32 343 3 12

Cycle 74 GMT 4/ 9/2017 13:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 28 14.50 490 3 3
2 3 1038.08 1 12.89 1914 3 3
3 7 2006.64 52 10.66 3253 3 3
4 13 1818.32 34 12.60 3022 3 3
5 13 913.84 34 13.39 1714 3 3
6 13 82.00 34 14.37 459 3 3
7 8 0.20 190 14.33 340 3 10

Cycle 73 GMT 25/ 8/2017 13: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 14.51 504 3 3
2 3 971.52 -1 14.51 504 3 3
3 7 2008.24 52 10.63 3276 3 3
4 13 1624.52 34 12.78 2771 3 3
5 13 778.92 34 13.52 1547 3 3
6 13 28.88 34 14.45 378 3 3
7 8 -0.04 190 14.30 338 3 15

Cycle 72 GMT 15/ 8/2017 12:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 14.53 495 3 3
2 7 2003.84 51 10.61 3296 3 3
3 13 1811.00 34 12.61 3046 3 3
4 13 893.32 34 13.42 1699 3 3
5 13 80.56 34 14.38 463 3 3
6 8 0.04 190 14.32 339 3 13

Cycle 71 GMT 5/ 8/2017 12:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 14.53 488 3 3
2 7 2003.72 51 10.69 3287 3 3
3 13 1813.44 34 12.64 3023 3 3
4 13 918.20 34 13.41 1743 3 3
5 13 94.68 34 14.35 489 3 3
6 8 -0.08 190 14.33 338 3 9

Cycle 70 GMT 26/ 7/2017 12:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 29 14.51 501 3 3
2 7 2009.28 51 10.68 3291 3 3
3 13 1813.28 34 12.65 3027 2 3
4 13 898.92 34 13.44 1699 3 3
5 13 87.24 34 14.36 479 3 3
6 8 0.08 190 14.32 344 3 11

Cycle 69 GMT 16/ 7/2017 12:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 29 14.53 512 3 3
2 7 2005.04 51 10.86 3292 3 3
3 13 1809.32 34 12.65 3022 2 3
4 13 912.32 34 13.43 1717 3 3
5 13 85.84 34 14.37 475 3 3
6 8 -0.08 190 14.30 344 3 12

Cycle 68 GMT 6/ 7/2017 11:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 29 14.50 491 3 3
2 3 970.00 -1 14.50 491 3 3
3 3 1039.96 1 13.16 1906 3 3
4 7 2001.76 51 10.87 3272 3 3
5 13 1601.24 34 12.86 2703 3 3
6 13 744.28 34 13.61 1480 3 3
7 13 25.00 34 14.46 378 3 3
8 8 0.12 190 14.29 344 3 15

Cycle 67 GMT 26/ 6/2017 11:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 14.55 504 3 3
2 7 2006.92 51 10.96 3275 3 3
3 13 1826.36 34 12.66 3059 2 3
4 13 891.84 34 13.46 1698 3 3
5 13 84.48 34 14.37 471 3 3
6 8 0.00 190 14.30 340 3 12

Cycle 66 GMT 16/ 6/2017 11:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 14.54 509 3 3
2 7 2006.48 52 11.05 3276 3 3
3 13 1807.40 34 12.69 3022 2 3
4 13 900.32 34 13.46 1710 3 3
5 13 79.48 34 14.39 459 3 3
6 8 0.20 190 14.31 343 3 11

Cycle 65 GMT 6/ 6/2017 11:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 29 14.55 506 3 3
2 7 2005.56 52 11.23 3301 3 3
3 13 1805.40 34 12.71 3024 2 3
4 13 850.68 34 13.52 1641 2 3
5 13 78.16 34 14.38 466 3 3
6 8 -0.12 190 14.30 344 3 13

Cycle 64 GMT 27/ 5/2017 11:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 29 14.56 498 3 3
2 7 2006.84 51 11.30 3272 3 3
3 13 1614.92 34 12.89 2752 2 3
4 13 731.64 34 13.64 1471 3 3
5 13 22.24 34 14.48 367 3 3
6 8 0.16 190 14.30 340 3 13

Cycle 63 GMT 17/ 5/2017 11:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 14.56 511 3 3
2 7 2003.64 51 11.34 3304 3 3
3 13 1606.84 34 12.91 2745 2 3
4 13 711.96 34 13.67 1443 2 3
5 13 20.80 34 14.46 377 3 3
6 8 0.08 190 14.28 346 3 12

Cycle 62 GMT 7/ 5/2017 11: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.57 515 3 3
2 7 2008.24 51 11.46 3303 3 3
3 13 1613.20 34 12.93 2747 3 3
4 13 744.08 34 13.65 1492 3 3
5 13 43.56 34 14.43 417 3 3
6 8 -0.12 190 14.28 349 3 12

Cycle 61 GMT 27/ 4/2017 10:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 29 14.54 506 3 3
2 7 2005.20 51 11.49 3282 3 3
3 13 1595.48 34 12.96 2733 2 3
4 13 706.32 34 13.69 1438 3 3
5 13 40.80 34 14.43 409 3 3
6 8 -0.04 190 14.27 349 3 11

Cycle 60 GMT 17/ 4/2017 10:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 14.59 492 3 3
2 7 2007.40 52 11.56 3309 3 3
3 13 1606.08 34 12.97 2738 2 3
4 13 720.44 34 13.69 1460 3 3
5 13 41.72 34 14.43 408 3 3
6 8 -0.08 190 14.28 345 3 15

Cycle 59 GMT 7/ 4/2017 10:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.60 500 3 3
2 7 2006.52 51 11.56 3322 3 3
3 13 1597.60 34 12.98 2743 2 3
4 13 711.12 34 13.69 1450 3 3
5 13 167.64 34 14.28 619 3 3
6 13 103.04 34 14.38 514 3 3
7 8 -0.08 190 14.31 345 3 61

Cycle 58 GMT 28/ 3/2017 10:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.60 499 3 3
2 7 2008.04 51 11.62 3317 3 3
3 13 1623.80 32 13.02 2769 2 3
4 13 738.36 32 13.71 1495 3 3
5 13 51.04 32 14.43 428 3 3
6 8 0.04 190 14.32 348 3 10

Cycle 57 GMT 18/ 3/2017 9:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 29 14.60 503 3 3
2 7 2007.28 51 11.73 3302 3 3
3 13 1581.04 32 13.07 2710 3 3
4 13 693.72 32 13.76 1420 3 3
5 13 44.96 32 14.44 419 3 3
6 8 0.00 190 14.28 349 3 12

Cycle 56 GMT 8/ 3/2017 9:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 29 14.61 509 3 3
2 7 2008.76 50 11.78 3287 3 3
3 13 1606.80 31 13.08 2710 2 3
4 13 743.48 31 13.72 1487 3 3
5 13 56.68 31 14.44 437 3 3
6 8 -0.08 190 14.33 347 3 8

Cycle 55 GMT 26/ 2/2017 9:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 14.60 497 3 3
2 7 2003.96 50 11.85 3287 3 3
3 13 1588.48 31 13.08 2710 3 3
4 13 902.72 31 13.61 1708 2 3
5 13 77.64 31 14.40 472 3 3
6 8 0.00 190 14.32 346 3 6

Cycle 54 GMT 16/ 2/2017 9:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 14.60 492 3 3
2 7 2004.28 50 11.98 3279 2 3
3 13 1585.96 31 13.10 2721 2 3
4 13 705.68 31 13.76 1431 3 3
5 13 26.76 31 14.48 386 3 3
6 8 -0.04 190 14.28 349 3 11

Cycle 53 GMT 6/ 2/2017 8:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 29 14.62 501 3 3
2 7 2002.60 50 12.08 3283 3 3
3 13 1591.96 31 13.11 2729 2 3
4 13 702.20 31 13.77 1419 3 3
5 13 45.00 31 14.45 414 3 3
6 8 -0.04 190 14.28 345 3 7

Cycle 52 GMT 27/ 1/2017 8:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 14.61 496 3 3
2 7 2010.04 50 12.21 3315 3 3
3 13 1595.44 31 13.12 2722 2 3
4 13 896.68 31 13.64 1686 2 3
5 13 38.04 31 14.46 404 3 3
6 8 0.08 190 14.28 345 3 12

Cycle 51 GMT 17/ 1/2017 8:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 29 14.62 504 3 3
2 7 2005.92 50 12.35 3287 3 3
3 13 1583.80 31 13.15 2697 2 3
4 13 692.80 31 13.78 1407 3 3
5 13 23.00 31 14.49 377 3 3
6 8 0.00 190 14.29 344 3 11

Cycle 50 GMT 7/ 1/2017 7:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 29 14.61 498 3 3
2 7 2007.20 50 12.43 3279 3 3
3 13 1398.56 31 13.28 2431 2 3
4 13 561.92 31 13.91 1208 3 3
5 13 27.28 31 14.49 384 3 3
6 8 0.04 190 14.29 343 3 14

Cycle 49 GMT 28/12/2016 7:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.62 507 3 3
2 7 2006.40 50 12.39 3332 3 3
3 13 1577.64 31 13.16 2684 2 3
4 13 685.60 31 13.79 1414 3 3
5 13 41.84 31 14.47 411 3 3
6 8 0.00 190 14.29 348 3 10

Cycle 48 GMT 18/12/2016 7: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 29 14.59 505 3 3
2 7 2005.44 50 12.40 3315 3 3
3 13 1403.72 31 13.26 2444 2 3
4 13 731.56 31 13.76 1478 3 3
5 13 20.16 31 14.49 379 3 3
6 8 0.08 190 14.28 348 3 12

Cycle 47 GMT 8/12/2016 6:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 14.60 508 3 3
2 7 2004.20 50 12.41 3327 3 3
3 13 1412.92 31 13.25 2466 2 3
4 13 747.08 31 13.74 1502 3 3
5 13 8.60 31 14.50 369 3 3
6 8 -0.08 190 14.26 358 3 12

Cycle 46 GMT 28/11/2016 6: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 29 14.63 513 3 3
2 7 2006.80 50 12.44 3312 3 3
3 13 1603.12 31 13.15 2743 3 3
4 13 693.64 31 13.79 1425 3 3
5 13 5.40 31 14.51 362 3 3
6 8 0.08 190 14.27 358 3 12

Cycle 45 GMT 18/11/2016 5:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 28 14.62 517 3 3
2 7 2005.84 50 12.45 3280 3 3
3 13 1405.96 31 13.27 2449 3 3
4 13 727.04 31 13.77 1462 3 3
5 8 0.24 190 14.35 343 3 4

Cycle 44 GMT 8/11/2016 5:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 14.63 508 3 3
2 7 2006.60 50 12.49 3283 3 3
3 13 1414.16 31 13.28 2443 2 3
4 13 567.68 31 13.91 1230 3 3
5 8 0.28 190 14.34 353 3 7

Cycle 43 GMT 29/10/2016 4:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 28 14.61 512 3 3
2 7 2003.32 50 12.51 3281 3 3
3 13 1579.00 31 13.19 2698 3 3
4 13 674.56 31 13.83 1395 3 3
5 13 5.08 31 14.54 356 3 3
6 8 -0.08 190 14.30 352 3 16

Cycle 42 GMT 19/10/2016 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 28 14.63 508 3 3
2 7 2007.96 50 12.51 3312 3 3
3 13 1586.44 31 13.20 2686 3 3
4 13 688.64 31 13.83 1411 3 3
5 13 5.56 31 14.55 358 3 3
6 8 0.00 190 14.29 355 3 13

Cycle 41 GMT 9/10/2016 4:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 14.66 514 3 3
2 7 2002.04 50 12.54 3271 3 3
3 13 1569.40 31 13.22 2674 3 3
4 13 661.32 31 13.86 1365 3 3
5 8 0.00 190 14.35 348 3 7

Cycle 40 GMT 29/ 9/2016 4:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 14.65 510 3 3
2 7 2006.48 50 12.55 3288 3 3
3 13 1574.20 30 13.23 2689 2 3
4 13 672.52 30 13.86 1394 3 3
5 13 17.16 30 14.56 373 3 3
6 8 -0.16 190 14.30 352 3 11

Cycle 39 GMT 19/ 9/2016 3:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.66 507 3 3
2 7 2006.84 50 12.58 3279 3 3
3 13 1574.20 30 13.24 2676 3 3
4 13 669.88 30 13.87 1393 3 3
5 13 5.68 30 14.59 358 3 3
6 8 -0.04 190 14.33 354 3 12

Cycle 38 GMT 9/ 9/2016 3:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 28 14.65 529 3 3
2 7 2002.44 50 12.61 3284 3 3
3 13 1383.08 30 13.35 2434 2 3
4 13 544.48 30 14.00 1202 3 3
5 8 0.16 190 14.37 356 3 4

Cycle 37 GMT 30/ 8/2016 2:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 28 14.67 517 3 3
2 7 2004.32 50 12.64 3290 3 3
3 13 1400.60 30 13.37 2449 3 3
4 13 730.40 30 13.85 1484 3 3
5 13 20.72 30 14.59 385 3 3
6 8 -0.04 190 14.34 355 3 14

Cycle 36 GMT 20/ 8/2016 2:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 28 14.68 512 3 3
2 7 2011.12 50 12.68 3283 3 3
3 13 1413.08 30 13.37 2462 2 3
4 13 731.16 30 13.85 1484 3 3
5 8 0.12 190 14.39 353 3 5

Cycle 35 GMT 10/ 8/2016 1:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 28 14.67 516 3 3
2 7 2003.36 50 12.72 3259 3 3
3 13 1385.52 30 13.41 2396 3 3
4 13 717.88 30 13.88 1451 3 3
5 8 0.04 190 14.40 348 3 5

Cycle 34 GMT 31/ 7/2016 1:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 28 14.70 513 3 3
2 7 2003.52 50 12.74 3271 3 3
3 13 1389.64 30 13.41 2421 2 3
4 13 539.36 30 14.04 1184 3 3
5 8 0.16 190 14.39 352 3 5

Cycle 33 GMT 21/ 7/2016 0:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 14.70 512 3 3
2 7 2004.80 50 12.81 3259 3 3
3 13 1387.04 30 13.42 2428 3 3
4 13 708.96 30 13.90 1439 3 3
5 8 0.12 190 14.40 349 3 5

Cycle 32 GMT 11/ 7/2016 0:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 14.70 514 3 3
2 7 2006.60 50 12.81 3314 3 3
3 13 1378.08 30 13.43 2416 2 3
4 13 516.84 30 14.08 1155 3 3
5 8 0.12 190 14.40 354 3 6

Cycle 31 GMT 30/ 6/2016 23:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 28 14.70 514 3 3
2 7 2008.16 50 12.88 3295 3 3
3 13 1382.04 30 13.45 2419 3 3
4 13 533.64 30 14.08 1177 3 3
5 8 -0.08 190 14.40 355 3 4

Cycle 30 GMT 20/ 6/2016 23: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 28 14.70 512 3 3
2 7 2002.92 50 12.90 3284 3 3
3 13 1382.72 30 13.47 2395 3 3
4 13 701.12 30 13.93 1431 3 3
5 13 6.32 30 14.64 362 3 3
6 8 -0.12 190 14.35 354 3 14

Cycle 29 GMT 10/ 6/2016 22:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 28 14.71 510 3 3
2 7 2008.52 50 12.94 3246 3 3
3 13 1382.08 30 13.49 2365 3 3
4 13 694.72 30 13.95 1409 3 3
5 8 0.20 190 14.40 352 3 6

Cycle 28 GMT 31/ 5/2016 22:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 14.70 507 3 3
2 7 2002.24 50 12.95 3232 3 3
3 13 1561.76 30 13.38 2626 2 3
4 13 623.04 30 14.00 1317 3 3
5 8 0.16 190 14.39 351 3 5

Cycle 27 GMT 21/ 5/2016 22: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 14.72 508 3 3
2 7 2003.96 50 12.96 3255 3 3
3 13 1572.96 30 13.37 2682 3 3
4 13 655.52 30 13.99 1359 3 3
5 13 30.12 30 14.62 395 3 3
6 8 0.04 190 14.36 353 3 11

Cycle 26 GMT 11/ 5/2016 21:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 14.72 509 3 3
2 7 2006.00 50 12.95 3264 3 3
3 13 1381.80 30 13.50 2359 3 3
4 13 517.40 30 14.11 1152 3 3
5 13 24.12 30 14.63 391 3 3
6 8 0.04 190 14.37 351 3 11

Cycle 25 GMT 1/ 5/2016 21:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 28 14.73 507 3 3
2 7 2003.24 50 12.96 3231 3 3
3 13 1362.40 30 13.49 2369 3 3
4 13 482.76 30 14.13 1107 3 3
5 13 45.64 30 14.60 425 3 3
6 8 0.00 190 14.36 356 3 17

Cycle 24 GMT 21/ 4/2016 20:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 28 14.72 504 3 3
2 7 2003.32 50 12.95 3264 3 3
3 13 1357.16 30 13.48 2391 3 3
4 13 469.36 30 14.14 1087 3 3
5 13 23.48 30 14.64 387 3 3
6 8 -0.12 190 14.36 355 3 12

Cycle 23 GMT 11/ 4/2016 20:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 28 14.74 508 3 3
2 7 2006.92 50 12.95 3306 3 3
3 13 1384.60 30 13.48 2420 2 3
4 13 502.24 30 14.13 1135 3 3
5 13 45.72 30 14.61 428 3 3
6 8 0.00 190 14.37 356 3 11

Cycle 22 GMT 1/ 4/2016 19:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 28 14.74 523 3 3
2 7 2004.20 50 13.00 3214 3 3
3 13 1368.48 30 13.51 2381 2 3
4 13 518.08 30 14.11 1159 3 3
5 13 26.20 30 14.65 389 3 3
6 8 -0.04 190 14.37 353 3 16

Cycle 21 GMT 22/ 3/2016 19: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 28 14.75 496 3 3
2 7 2003.00 50 13.00 3273 3 3
3 13 1377.16 30 13.50 2408 3 3
4 13 694.96 30 13.98 1421 3 3
5 13 39.00 30 14.64 417 3 3
6 8 0.00 190 14.38 356 3 11

Cycle 20 GMT 12/ 3/2016 18:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 28 14.77 504 3 3
2 7 2004.52 50 13.02 3243 3 3
3 13 1367.96 30 13.52 2379 2 3
4 13 683.44 30 13.99 1408 3 3
5 13 33.60 30 14.65 408 3 3
6 8 0.00 190 14.38 354 3 15

Cycle 19 GMT 2/ 3/2016 18:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 28 14.80 497 3 3
2 7 2005.80 50 13.02 3258 3 3
3 13 1366.20 30 13.55 2316 3 3
4 13 678.00 30 14.00 1402 3 3
5 13 34.52 30 14.66 411 3 3
6 8 0.04 190 14.38 354 3 14

Cycle 18 GMT 21/ 2/2016 17:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 28 14.78 498 3 3
2 7 2001.56 50 13.04 3253 3 3
3 13 1365.80 30 13.54 2381 3 3
4 13 483.56 30 14.17 1103 3 3
5 13 21.96 30 14.70 387 3 3
6 8 -0.08 190 14.40 352 3 20

Cycle 17 GMT 11/ 2/2016 17:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 27 14.78 510 3 3
2 7 2002.20 50 13.07 3234 3 3
3 13 1375.64 30 13.54 2401 3 3
4 13 487.04 30 14.18 1117 3 3
5 13 9.48 30 14.74 363 3 3
6 8 -0.08 190 14.40 350 3 15

Cycle 16 GMT 1/ 2/2016 16:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 27 14.79 510 3 3
2 7 2005.16 50 13.06 3279 3 3
3 13 1361.40 30 13.54 2399 2 3
4 13 676.44 30 14.02 1406 3 3
5 13 32.48 30 14.71 408 3 3
6 8 0.28 190 14.42 354 3 17

Cycle 15 GMT 22/ 1/2016 16:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 27 14.81 508 3 3
2 7 2004.72 50 13.09 3244 3 3
3 13 1356.56 28 13.58 2391 3 3
4 13 675.44 28 14.05 1398 3 3
5 13 35.44 28 14.72 412 3 3
6 8 0.04 190 14.42 353 3 13

Cycle 14 GMT 12/ 1/2016 15:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 27 14.82 498 3 3
2 7 2004.80 50 13.09 3273 3 3
3 13 1373.84 28 13.58 2411 3 3
4 13 703.84 28 14.02 1448 2 3
5 13 43.40 28 14.72 426 3 3
6 8 0.20 190 14.43 353 3 12

Cycle 13 GMT 2/ 1/2016 15:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.81 507 3 3
2 7 2002.32 50 13.09 3282 3 3
3 13 1355.56 28 13.61 2345 3 3
4 13 702.32 28 14.02 1447 3 3
5 13 47.88 28 14.72 437 3 3
6 8 0.00 190 14.42 356 3 12

Cycle 12 GMT 23/12/2015 14:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 27 14.80 506 3 3
2 7 2002.20 50 13.10 3268 3 3
3 13 1370.36 28 13.58 2415 3 3
4 13 508.00 28 14.17 1166 3 3
5 13 22.80 28 14.75 398 3 3
6 8 0.00 190 14.41 359 3 14

Cycle 11 GMT 13/12/2015 13:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 27 14.82 515 3 3
2 7 2002.88 50 13.10 3283 3 3
3 13 1556.44 28 13.48 2673 3 3
4 13 636.20 28 14.07 1352 3 3
5 13 29.92 28 14.75 410 3 3
6 8 0.04 190 14.41 365 3 15

Cycle 10 GMT 3/12/2015 13:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 27 14.81 515 3 3
2 7 2005.00 50 13.10 3276 3 3
3 13 1365.36 25 13.64 2407 2 3
4 13 705.92 25 14.06 1458 3 3
5 13 52.68 25 14.75 447 3 3
6 8 -0.04 190 14.45 359 3 10

Cycle 9 GMT 23/11/2015 12:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 26 14.80 525 3 3
2 3 1021.04 1 14.62 1922 3 3
3 7 2005.12 50 13.09 3299 2 3
4 13 1354.56 25 13.65 2365 3 3
5 13 705.64 25 14.06 1463 3 3
6 13 54.96 25 14.74 467 3 3
7 8 0.04 190 14.41 370 3 8

Cycle 8 GMT 13/11/2015 11:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 26 14.84 432 3 3
2 7 2004.24 50 13.10 3211 3 3
3 13 1338.92 25 13.65 2334 3 3
4 13 493.24 25 14.22 1158 3 3
5 13 30.84 25 14.76 435 3 3
6 8 0.08 190 14.38 376 3 10

Cycle 7 GMT 3/11/2015 10:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 25 14.82 436 3 3
2 7 2001.56 50 13.09 3200 3 3
3 13 1352.40 25 13.63 2319 2 3
4 13 694.52 25 14.10 1355 3 3
5 13 45.68 25 14.80 353 3 3
6 8 0.00 190 14.51 279 3 12

Cycle 6 GMT 24/10/2015 10:26:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 25 14.85 434 3 3
2 3 1023.24 1 14.67 1900 3 3
3 7 2000.84 50 13.07 3201 3 3
4 13 1175.52 25 13.72 2034 2 3
5 13 541.96 25 14.21 1131 3 3
6 8 0.20 190 14.52 285 3 5

Cycle 5 GMT 14/10/2015 9:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 25 14.82 435 3 3
2 7 2002.36 50 13.03 3196 3 3
3 13 1345.44 25 13.61 2249 2 3
4 13 674.96 25 14.09 1320 3 3
5 13 6.56 25 14.86 285 3 3
6 8 0.12 232 14.46 276 3 128

Cycle 4 GMT 4/10/2015 8:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 25 14.77 430 3 3
2 7 1505.32 50 13.29 2533 3 3
3 13 1102.56 25 13.75 1935 2 3
4 13 430.04 25 14.27 957 3 3
5 8 0.00 240 14.45 276 3 49

Cycle 3 GMT 3/10/2015 8:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 25 14.75 427 3 3
2 7 1513.12 74 13.07 2529 3 3
3 13 564.20 20 14.18 1149 3 3
4 13 160.16 20 14.61 530 3 3
5 8 0.12 239 14.44 276 3 105

Cycle 2 GMT 2/10/2015 9:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 25 14.69 430 3 3
2 7 1515.88 74 12.96 2544 3 3
3 13 755.52 20 13.96 1437 3 3
4 13 131.44 20 14.59 481 3 3
5 8 0.08 240 14.40 274 3 98

Cycle 1 GMT 1/10/2015 10: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 25 14.76 402 3 3
2 7 981.24 75 13.21 1748 3 3
3 8 0.16 240 14.38 268 3 64

Cycle 0 GMT 30/ 9/2015 22:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 96.60 24 14.67 402 3 3
2 7 106.76 74 14.40 405 3 3
3 8 0.28 232 14.55 241 3 244