SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8473 WMO= 5902481


Cycle 301 GMT 16/12/2024 3:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 14.81 510 2 3
2 7 2003.20 43 14.27 3144 2 3
3 13 1735.24 19 14.28 2781 2 4
4 13 997.28 19 14.51 1776 2 5
5 13 426.72 19 14.74 969 2 5
6 8 0.00 170 14.87 359 2 11

Cycle 300 GMT 6/12/2024 3:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 29 15.00 512 2 3
2 7 2005.20 44 14.26 3138 3 4
3 13 1593.52 19 14.31 2589 2 3
4 13 1013.28 19 14.50 1795 2 4
5 13 439.52 19 14.74 981 2 4
6 13 13.04 19 14.92 396 2 4
7 8 0.56 170 14.85 363 2 12

Cycle 299 GMT 26/11/2024 2: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 14.82 523 2 3
2 7 2007.52 43 14.27 3149 2 2
3 13 1739.92 19 14.29 2789 2 6
4 13 1151.44 19 14.45 1995 2 7
5 13 430.96 19 14.75 973 2 4
6 8 -0.32 170 14.87 362 2 16

Cycle 298 GMT 16/11/2024 2:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 29 14.98 526 2 2
2 7 2002.64 43 14.27 3138 2 2
3 13 1597.28 19 14.32 2610 2 5
4 13 1015.68 19 14.51 1810 2 6
5 13 437.92 19 14.74 982 2 4
6 8 -0.08 170 14.86 368 2 16

Cycle 297 GMT 6/11/2024 0:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 29 15.00 513 2 3
2 7 2003.92 43 14.27 3143 2 3
3 13 1599.24 19 14.31 2612 2 7
4 13 1031.56 19 14.50 1823 2 4
5 13 444.88 19 14.74 992 2 5
6 13 15.80 19 14.91 401 2 5
7 8 -0.28 170 14.85 364 2 8

Cycle 296 GMT 26/10/2024 23:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 29 14.82 517 2 3
2 7 2002.80 43 14.28 3136 3 3
3 13 1584.92 19 14.32 2582 2 3
4 13 1019.96 19 14.50 1806 2 5
5 13 451.36 19 14.74 992 2 5
6 8 1.52 170 14.87 359 2 11

Cycle 295 GMT 16/10/2024 23:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 29 14.81 518 2 3
2 7 2001.72 43 14.28 3143 3 2
3 13 1717.12 19 14.29 2764 2 4
4 13 994.48 19 14.52 1772 2 8
5 13 422.56 19 14.75 960 2 5
6 13 60.08 19 14.90 457 2 6
7 8 -0.12 170 14.86 362 2 10

Cycle 294 GMT 6/10/2024 23:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 29 14.82 508 2 3
2 7 2003.16 43 14.28 3142 3 2
3 13 1592.32 19 14.32 2600 2 5
4 13 1024.44 19 14.51 1813 2 5
5 13 447.28 19 14.74 1001 2 5
6 8 0.00 170 14.86 373 2 12

Cycle 293 GMT 27/ 9/2024 0: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 29 14.80 529 2 4
2 7 2003.80 43 14.28 3134 2 4
3 13 1597.80 19 14.31 2608 2 5
4 13 897.64 19 14.56 1636 2 8
5 13 346.16 19 14.78 858 2 5
6 8 0.20 170 14.87 368 2 10

Cycle 292 GMT 17/ 9/2024 0:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 14.98 521 2 3
2 7 2008.56 43 14.27 3142 2 2
3 13 1591.08 19 14.32 2600 2 4
4 13 1041.00 19 14.50 1835 2 8
5 13 449.72 19 14.74 1001 2 5
6 8 0.12 170 14.86 376 2 12

Cycle 291 GMT 6/ 9/2024 22:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 14.80 529 2 5
2 7 2005.00 44 14.28 3132 5 3
3 13 1587.44 19 14.31 2599 2 5
4 13 1151.64 19 14.44 1997 2 6
5 13 408.28 19 14.76 940 2 6
6 13 28.12 19 14.91 424 2 4
7 8 0.00 170 14.85 361 2 16

Cycle 290 GMT 27/ 8/2024 23: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 29 14.81 518 2 4
2 7 2008.56 43 14.28 3135 2 3
3 13 1601.52 19 14.31 2628 2 6
4 13 1030.00 19 14.50 1833 2 6
5 13 467.16 19 14.73 1023 2 4
6 13 17.12 19 14.91 411 2 4
7 8 0.56 170 14.85 370 2 11

Cycle 289 GMT 17/ 8/2024 23:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 29 14.80 528 2 4
2 7 2006.96 43 14.28 3130 4 2
3 13 1594.52 19 14.31 2602 2 4
4 13 913.12 19 14.56 1665 2 4
5 13 485.96 19 14.72 1052 2 5
6 8 -0.04 170 14.86 373 2 11

Cycle 288 GMT 7/ 8/2024 23:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 14.98 522 2 4
2 7 2004.88 44 14.27 3123 2 4
3 13 1597.28 19 14.31 2616 2 6
4 13 1021.40 19 14.51 1822 2 5
5 13 428.72 19 14.75 970 2 5
6 13 27.60 19 14.90 427 2 4
7 8 0.16 170 14.84 374 2 14

Cycle 287 GMT 28/ 7/2024 22:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 29 14.97 532 2 3
2 7 2009.00 43 14.28 3135 2 2
3 13 1482.96 19 14.35 2469 2 5
4 13 1064.96 19 14.49 1876 2 7
5 13 344.16 19 14.78 855 2 4
6 8 0.20 170 14.86 371 2 12

Cycle 286 GMT 18/ 7/2024 20:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 29 14.81 523 2 4
2 7 2009.12 44 14.27 3123 2 3
3 13 1610.16 19 14.30 2638 2 6
4 13 1046.80 19 14.50 1839 2 7
5 13 322.68 19 14.80 819 2 4
6 13 18.04 19 14.92 401 2 4
7 8 0.00 170 14.85 362 2 12
8 14 0.00 20 14.83 367 2 14

Cycle 285 GMT 8/ 7/2024 20:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 14.81 522 2 4
2 7 2007.32 44 14.27 3153 2 3
3 13 1590.72 19 14.31 2605 2 4
4 13 1016.44 19 14.51 1802 2 6
5 13 315.04 19 14.81 810 2 5
6 8 0.04 170 14.86 369 2 12

Cycle 284 GMT 28/ 6/2024 20:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 29 14.98 534 2 3
2 7 2002.60 43 14.27 3151 2 3
3 13 1597.04 19 14.32 2609 2 6
4 13 1013.80 19 14.51 1812 2 4
5 13 435.92 19 14.75 982 2 4
6 13 29.00 19 14.91 428 2 4
7 8 0.20 170 14.85 368 2 12

Cycle 283 GMT 18/ 6/2024 19:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.00 521 2 3
2 7 2001.64 43 14.28 3132 2 3
3 13 1584.12 19 14.33 2595 2 6
4 13 1003.64 19 14.52 1781 2 8
5 13 436.52 19 14.75 990 2 5
6 8 0.28 170 14.86 375 2 19

Cycle 282 GMT 8/ 6/2024 17:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 29 14.98 529 2 3
2 7 2005.48 43 14.28 3117 2 4
3 13 1729.64 19 14.29 2775 2 5
4 13 999.20 19 14.53 1772 2 7
5 13 434.88 19 14.75 979 2 4
6 8 0.00 170 14.87 364 2 13

Cycle 281 GMT 29/ 5/2024 16:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 14.82 515 2 3
2 7 2006.56 44 14.27 3142 2 4
3 13 1590.72 19 14.32 2595 2 3
4 13 999.08 19 14.52 1771 2 6
5 13 413.24 19 14.76 946 2 5
6 13 78.40 19 14.90 485 2 6
7 13 42.76 19 14.90 434 2 5
8 8 -0.08 170 14.85 357 2 22

Cycle 280 GMT 19/ 5/2024 16:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 29 14.81 528 2 3
2 7 2004.04 43 14.28 3144 2 4
3 13 1599.72 19 14.32 2611 2 4
4 13 892.28 19 14.57 1628 2 5
5 13 335.16 19 14.79 850 2 6
6 8 0.28 170 14.87 367 2 11

Cycle 279 GMT 9/ 5/2024 16:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 14.82 519 2 3
2 7 2003.12 43 14.28 3156 2 4
3 13 1588.92 19 14.32 2600 2 5
4 13 1019.48 19 14.51 1818 2 5
5 13 439.08 19 14.75 998 2 5
6 13 13.96 19 14.92 409 2 5
7 8 0.04 170 14.85 377 2 10

Cycle 278 GMT 29/ 4/2024 16:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 29 14.82 529 2 3
2 7 2003.52 44 14.28 3151 2 3
3 13 1457.84 19 14.36 2432 2 4
4 13 891.92 19 14.56 1628 2 4
5 13 326.76 19 14.80 835 2 6
6 8 0.44 170 14.87 366 2 16

Cycle 277 GMT 19/ 4/2024 16:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 14.83 515 2 3
2 7 2002.48 43 14.29 3128 3 4
3 13 1597.40 19 14.33 2615 2 4
4 13 1040.72 19 14.51 1827 2 4
5 13 332.92 19 14.80 830 2 5
6 13 18.76 19 14.93 399 2 4
7 8 0.12 170 14.87 360 2 8

Cycle 276 GMT 9/ 4/2024 17: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 29 14.82 505 2 3
2 7 2007.04 43 14.29 3150 2 2
3 13 1601.12 19 14.33 2615 2 4
4 13 1030.36 19 14.51 1828 2 5
5 13 444.00 19 14.75 990 2 4
6 8 -0.12 170 14.88 360 2 11

Cycle 275 GMT 30/ 3/2024 17:20: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 28 14.84 517 2 2
2 7 2004.00 43 14.29 3135 2 4
3 13 1592.64 19 14.34 2610 2 5
4 13 1043.32 19 14.50 1852 2 4
5 13 458.52 19 14.74 1024 2 5
6 13 15.32 19 14.93 404 2 5
7 8 0.08 170 14.86 369 2 12

Cycle 274 GMT 20/ 3/2024 17:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 14.97 501 2 2
2 7 2008.76 43 14.29 3140 2 2
3 13 1600.48 19 14.33 2601 2 5
4 13 1034.68 19 14.51 1824 2 5
5 13 459.48 19 14.74 1013 2 4
6 8 0.32 170 14.88 360 2 16

Cycle 273 GMT 10/ 3/2024 16:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 28 15.02 502 2 2
2 7 2004.52 43 14.29 3133 2 3
3 13 1466.44 19 14.37 2420 2 5
4 13 922.92 19 14.55 1667 2 4
5 13 355.00 19 14.78 867 2 4
6 13 22.28 19 14.93 401 2 4
7 8 -0.32 170 14.87 355 2 18

Cycle 272 GMT 29/ 2/2024 14:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 29 15.03 513 2 2
2 7 2006.56 43 14.29 3137 2 4
3 13 1457.00 19 14.37 2412 2 4
4 13 1043.32 19 14.50 1840 2 5
5 13 327.04 19 14.80 826 2 4
6 8 0.80 170 14.87 360 2 9

Cycle 271 GMT 19/ 2/2024 13:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 14.83 508 2 3
2 7 2004.12 43 14.30 3143 3 3
3 13 1595.16 19 14.33 2600 2 4
4 13 913.40 19 14.56 1655 2 7
5 13 488.64 19 14.73 1048 2 5
6 13 20.48 19 14.93 401 2 5
7 8 0.08 170 14.87 353 2 18

Cycle 270 GMT 9/ 2/2024 13:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 28 14.82 506 2 2
2 7 2004.48 43 14.30 3137 2 3
3 13 1467.76 19 14.37 2430 2 4
4 13 1037.60 19 14.50 1829 2 4
5 13 329.72 19 14.80 835 2 4
6 8 0.64 170 14.88 351 2 9

Cycle 269 GMT 30/ 1/2024 13:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 29 15.01 513 2 2
2 7 2008.52 44 14.28 3148 2 3
3 13 1592.60 19 14.33 2588 2 6
4 13 1014.52 19 14.52 1802 2 8
5 13 299.32 19 14.82 790 2 4
6 13 75.52 19 14.90 478 2 4
7 8 0.12 170 14.87 354 2 17

Cycle 268 GMT 20/ 1/2024 12:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 14.83 516 2 3
2 7 2004.84 43 14.30 3123 3 2
3 13 1592.60 19 14.33 2601 2 7
4 13 898.88 19 14.57 1632 2 5
5 13 340.76 19 14.80 842 2 4
6 13 20.48 19 14.93 399 2 5
7 8 -0.40 170 14.87 354 2 12

Cycle 267 GMT 10/ 1/2024 12:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 14.83 511 2 3
2 7 2002.80 43 14.30 3134 2 3
3 13 1732.20 19 14.30 2799 2 4
4 13 995.72 19 14.53 1772 2 5
5 13 429.36 19 14.76 970 2 5
6 8 0.48 170 14.87 365 2 11

Cycle 266 GMT 31/12/2023 12:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 29 14.84 511 2 2
2 7 2006.28 43 14.30 3127 2 2
3 13 1742.40 19 14.29 2798 2 3
4 13 1150.68 19 14.46 1996 2 6
5 13 404.04 19 14.77 942 2 5
6 8 -0.28 170 14.87 365 2 10

Cycle 265 GMT 21/12/2023 12:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 29 15.03 510 2 2
2 7 2002.32 43 14.29 3138 2 3
3 13 1592.64 19 14.34 2599 2 4
4 13 1017.60 19 14.52 1810 2 5
5 13 439.96 19 14.75 991 2 4
6 8 0.72 170 14.88 359 2 10

Cycle 264 GMT 11/12/2023 11:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 28 15.03 510 2 2
2 7 2002.60 43 14.30 3131 2 3
3 13 1599.96 19 14.33 2614 2 6
4 13 1030.16 19 14.51 1825 2 5
5 13 455.28 19 14.76 1006 2 5
6 8 -0.16 170 14.89 353 2 12

Cycle 263 GMT 1/12/2023 10: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 15.03 509 2 2
2 7 2003.92 43 14.30 3142 2 2
3 13 1731.00 19 14.30 2778 2 5
4 13 1020.56 19 14.52 1807 2 4
5 13 466.16 19 14.75 1024 2 4
6 8 -0.08 170 14.89 356 2 14
7 14 -0.08 20 14.86 353 2 12

Cycle 262 GMT 21/11/2023 8:37: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 29 14.82 517 2 2
2 7 2003.32 43 14.30 3129 2 4
3 13 1721.60 19 14.31 2779 2 3
4 13 1126.72 19 14.47 1962 2 7
5 13 403.00 19 14.78 935 2 4
6 8 0.44 170 14.89 353 2 8

Cycle 261 GMT 11/11/2023 9: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 14.84 506 2 2
2 3 1018.88 1 15.09 1866 2 2
3 7 2002.88 43 14.30 3130 2 2
4 13 1716.56 19 14.30 2759 2 3
5 13 1149.76 19 14.46 1990 2 6
6 13 563.52 19 14.70 1148 2 5
7 13 11.84 19 14.94 390 2 4
8 8 0.16 170 14.87 357 2 14

Cycle 260 GMT 1/11/2023 9: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 30 14.83 520 2 2
2 3 969.20 -1 15.39 0 2 2
3 7 2006.72 43 14.30 3138 2 3
4 13 1588.88 19 14.33 2594 2 4
5 13 1156.04 19 14.45 1997 2 3
6 13 545.88 19 14.71 1131 2 6
7 8 0.00 170 14.89 359 2 10

Cycle 259 GMT 22/10/2023 9:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 14.84 506 2 2
2 3 1024.52 1 15.08 1858 2 2
3 7 2005.00 43 14.29 3142 2 3
4 13 1733.76 19 14.30 2787 2 4
5 13 1019.08 19 14.53 1808 2 5
6 13 439.60 19 14.76 980 2 4
7 13 69.52 19 14.91 469 2 4
8 8 0.16 170 14.87 351 2 12

Cycle 258 GMT 12/10/2023 9:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 27 14.99 509 2 2
2 10 1020.48 3 14.88 1817 2 4
3 7 2008.92 43 14.29 3142 4 2
4 13 1891.32 19 14.25 2989 2 3
5 13 1033.56 19 14.52 1828 2 6
6 13 362.12 19 14.79 878 2 4
7 8 0.04 170 14.88 356 2 10

Cycle 257 GMT 2/10/2023 8:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 28 14.83 508 2 2
2 3 971.24 -1 15.38 0 2 2
3 7 2008.24 43 14.28 3142 2 3
4 13 1742.88 19 14.28 2791 2 4
5 13 1139.96 19 14.47 1980 2 6
6 13 688.28 19 14.64 1329 2 6
7 13 24.32 19 14.92 419 2 4
8 8 0.04 170 14.86 367 2 13

Cycle 256 GMT 22/ 9/2023 8:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 28 14.89 513 2 2
2 7 2010.48 43 14.27 3136 2 2
3 13 1898.08 19 14.24 3003 2 2
4 13 1275.92 19 14.40 2167 2 7
5 13 246.64 19 14.84 722 2 4
6 8 0.04 170 14.88 358 2 8

Cycle 255 GMT 12/ 9/2023 8:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 14.83 500 2 2
2 10 1026.92 3 14.80 1826 2 5
3 3 930.24 -1 15.35 0 2 5
4 3 934.16 -1 15.38 0 2 5
5 7 2006.44 43 14.29 3129 5 2
6 13 1461.28 19 14.37 2421 2 4
7 13 1329.84 19 14.36 2238 2 6
8 13 527.88 19 14.72 1090 2 4
9 13 22.12 19 14.93 385 2 4
10 8 -0.08 170 14.87 341 2 19
11 14 -0.08 20 14.85 347 2 11

Cycle 254 GMT 2/ 9/2023 8:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 28 14.84 492 2 2
2 3 1020.64 1 15.04 1849 2 2
3 7 2003.00 43 14.27 3144 2 2
4 13 1452.84 19 14.36 2412 2 7
5 13 1035.12 19 14.50 1833 2 5
6 13 444.52 19 14.74 986 2 4
7 8 0.20 170 14.88 350 2 8

Cycle 253 GMT 23/ 8/2023 8:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 15.02 511 2 2
2 3 970.24 -1 15.40 0 2 2
3 7 2002.36 43 14.28 3135 2 2
4 13 1602.80 19 14.32 2614 2 3
5 13 903.44 19 14.57 1655 2 7
6 13 479.20 19 14.73 1046 2 4
7 13 37.76 19 14.92 417 2 3
8 8 -0.04 170 14.87 344 2 11

Cycle 252 GMT 13/ 8/2023 7:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 29 14.84 506 2 2
2 7 2005.60 43 14.28 3141 2 3
3 13 1590.96 19 14.32 2590 2 4
4 13 1045.52 19 14.50 1850 2 5
5 13 472.64 19 14.73 1037 2 4
6 13 51.76 19 14.92 430 2 4
7 8 0.00 170 14.88 342 2 16

Cycle 251 GMT 3/ 8/2023 7:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 29 15.04 512 2 2
2 7 2010.92 43 14.27 3147 2 3
3 13 1495.32 19 14.35 2475 2 3
4 13 1089.84 19 14.48 1909 2 6
5 13 658.20 19 14.65 1291 2 5
6 8 0.20 170 14.89 343 2 11

Cycle 250 GMT 24/ 7/2023 6: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 27 14.97 517 2 2
2 3 1063.48 2 14.90 1893 2 4
3 7 2006.20 43 14.29 3149 2 2
4 13 1739.52 19 14.29 2789 2 3
5 13 1161.60 19 14.46 2001 2 5
6 13 446.48 19 14.77 1001 2 3
7 8 0.40 170 14.90 337 2 21

Cycle 249 GMT 14/ 7/2023 4:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 28 14.99 518 2 2
2 3 973.28 -1 15.37 0 2 2
3 7 2009.44 43 14.27 3146 2 2
4 13 1472.44 19 14.36 2433 2 6
5 13 1048.04 19 14.49 1849 2 7
6 13 463.88 19 14.72 1017 2 4
7 13 37.68 19 14.89 431 2 3
8 8 -0.04 170 14.83 356 2 9

Cycle 248 GMT 4/ 7/2023 3: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 28 14.99 514 2 2
2 7 2006.16 43 14.27 3140 2 3
3 13 1734.20 19 14.28 2782 2 3
4 13 1009.32 19 14.51 1792 2 5
5 13 444.12 19 14.72 993 2 4
6 8 0.00 170 14.85 359 2 10

Cycle 247 GMT 24/ 6/2023 1:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 29 14.81 507 2 2
2 7 2007.08 43 14.28 3143 2 3
3 13 1604.00 19 14.32 2615 2 4
4 13 1033.52 19 14.50 1821 2 6
5 13 451.56 19 14.72 991 2 4
6 8 0.44 170 14.86 348 2 14

Cycle 246 GMT 14/ 6/2023 1:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 28 14.81 505 2 2
2 3 1023.20 1 15.00 1843 2 2
3 7 2003.56 43 14.27 3148 2 3
4 13 1734.36 19 14.28 2801 2 5
5 13 1026.40 19 14.50 1819 2 3
6 13 453.24 19 14.72 999 2 4
7 8 -0.28 170 14.85 349 2 12

Cycle 245 GMT 4/ 6/2023 1:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 28 15.00 503 2 2
2 7 2005.52 44 14.27 3137 2 4
3 13 1733.04 19 14.27 2787 2 4
4 13 1133.60 19 14.46 1966 2 5
5 13 379.28 19 14.75 899 2 4
6 13 22.32 19 14.90 394 2 3
7 8 0.32 170 14.84 350 2 8

Cycle 244 GMT 25/ 5/2023 0:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 28 14.99 523 2 2
2 7 2003.44 43 14.28 3135 2 2
3 13 1715.52 19 14.29 2764 2 5
4 13 1124.80 19 14.46 1951 2 4
5 13 550.00 19 14.69 1136 2 4
6 8 0.12 170 14.87 340 2 8

Cycle 243 GMT 14/ 5/2023 23: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 28 15.00 507 2 2
2 7 2002.44 44 14.27 3134 2 2
3 13 1591.84 19 14.32 2599 2 5
4 13 1019.16 19 14.50 1809 2 5
5 13 320.40 19 14.78 819 2 4
6 13 35.28 19 14.90 408 2 4
7 13 14.12 19 14.90 371 2 4
8 8 -0.12 170 14.84 338 2 11

Cycle 242 GMT 4/ 5/2023 21:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 15.00 503 2 2
2 7 2005.48 43 14.28 3140 2 2
3 13 1588.68 19 14.32 2603 2 3
4 13 1162.08 19 14.45 2006 2 5
5 13 442.16 19 14.73 988 2 5
6 13 27.20 19 14.90 391 2 3
7 8 0.04 170 14.85 342 2 11

Cycle 241 GMT 24/ 4/2023 20: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 14.82 514 2 2
2 7 2003.28 43 14.28 3137 2 3
3 13 1589.68 19 14.32 2591 2 4
4 13 1029.24 19 14.49 1815 2 7
5 13 458.00 19 14.72 1007 2 4
6 13 15.04 19 14.91 373 2 4
7 8 0.20 170 14.85 341 2 8

Cycle 240 GMT 14/ 4/2023 20:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 28 14.81 514 2 2
2 7 2002.08 43 14.29 3128 2 3
3 13 1588.48 19 14.33 2587 2 4
4 13 1032.44 19 14.49 1828 2 4
5 13 455.84 19 14.72 1004 2 4
6 13 5.48 19 14.91 364 2 3
7 8 -0.28 170 14.85 345 2 14

Cycle 239 GMT 4/ 4/2023 20:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 28 14.82 498 2 2
2 7 2002.04 43 14.28 3132 2 2
3 13 1597.84 19 14.32 2612 2 5
4 13 1032.60 19 14.49 1821 2 5
5 13 592.24 19 14.66 1186 2 4
6 8 0.24 170 14.85 344 2 9

Cycle 238 GMT 25/ 3/2023 21: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.02 483 2 2
2 7 2006.16 44 14.27 3133 2 2
3 13 1593.08 19 14.32 2597 2 4
4 13 1019.56 19 14.49 1807 2 4
5 13 435.12 19 14.73 977 2 3
6 13 30.92 19 14.90 393 2 3
7 8 0.20 170 14.85 339 2 9
8 14 0.20 20 14.82 341 2 16

Cycle 237 GMT 15/ 3/2023 19:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 29 15.01 489 2 2
2 7 2003.40 43 14.28 3133 2 3
3 13 1605.64 19 14.32 2628 2 4
4 13 1175.36 19 14.44 2017 2 7
5 13 439.00 19 14.73 977 2 4
6 13 64.80 19 14.89 441 2 4
7 8 0.04 170 14.86 331 2 14

Cycle 236 GMT 5/ 3/2023 18:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 29 14.84 493 2 2
2 7 2006.96 44 14.29 3127 2 4
3 13 1599.44 19 14.32 2599 2 5
4 13 1023.80 19 14.50 1810 2 5
5 13 328.48 19 14.78 826 2 4
6 13 17.52 19 14.91 371 2 3
7 8 -0.04 170 14.86 331 2 15

Cycle 235 GMT 23/ 2/2023 18:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.84 491 2 2
2 7 2005.32 43 14.29 3135 2 3
3 13 1597.96 19 14.32 2592 2 6
4 13 1041.76 19 14.49 1839 2 5
5 13 340.48 19 14.77 842 2 4
6 8 0.12 170 14.87 334 2 11

Cycle 234 GMT 13/ 2/2023 18:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 14.84 498 2 2
2 7 2004.52 43 14.29 3138 2 3
3 13 1599.12 19 14.32 2600 2 3
4 13 1044.40 19 14.49 1840 2 5
5 13 348.80 19 14.77 851 2 4
6 8 -0.20 170 14.87 333 2 11

Cycle 233 GMT 3/ 2/2023 19:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 28 14.83 503 2 2
2 7 2008.80 43 14.29 3130 2 4
3 13 1741.08 19 14.29 2788 2 5
4 13 1033.92 19 14.49 1828 2 4
5 13 467.92 19 14.72 1019 2 4
6 8 0.28 170 14.87 337 2 10

Cycle 232 GMT 24/ 1/2023 19:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 28 14.83 494 2 2
2 7 2004.76 44 14.29 3138 2 3
3 13 1477.64 19 14.35 2457 2 4
4 13 933.92 19 14.52 1694 2 3
5 13 370.04 19 14.75 894 2 3
6 8 -0.04 170 14.86 341 2 15

Cycle 231 GMT 14/ 1/2023 19:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 15.01 502 2 2
2 7 2003.00 43 14.30 3130 2 4
3 13 1722.64 19 14.29 2776 2 5
4 13 1140.84 19 14.45 1971 2 6
5 13 421.84 19 14.74 960 2 4
6 8 0.00 170 14.86 338 2 10

Cycle 230 GMT 4/ 1/2023 18:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 28 14.84 501 2 2
2 7 2006.44 43 14.29 3131 2 4
3 13 1594.92 19 14.32 2597 2 3
4 13 1038.64 19 14.49 1828 2 5
5 13 461.52 19 14.71 1013 2 3
6 8 0.20 170 14.86 340 2 6

Cycle 229 GMT 25/12/2022 18:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 14.82 510 2 2
2 7 2005.84 44 14.29 3137 2 3
3 13 1726.56 19 14.28 2781 2 4
4 13 998.20 19 14.50 1774 2 5
5 13 298.72 19 14.79 786 2 5
6 8 -0.08 170 14.86 338 2 8

Cycle 228 GMT 15/12/2022 18:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 29 14.92 500 2 2
2 7 2006.12 43 14.29 3134 2 3
3 13 1601.48 19 14.32 2607 2 6
4 13 1042.04 19 14.49 1841 2 7
5 13 465.28 19 14.71 1022 2 4
6 8 0.16 170 14.86 344 2 9

Cycle 227 GMT 5/12/2022 18:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 29 14.82 500 2 2
2 7 2003.32 43 14.30 3130 2 4
3 13 1596.12 19 14.33 2600 2 3
4 13 1034.60 19 14.48 1821 2 5
5 13 333.04 19 14.77 833 2 4
6 8 0.12 170 14.86 340 2 10

Cycle 226 GMT 25/11/2022 18:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 14.82 505 2 2
2 7 2005.32 43 14.30 3142 2 3
3 13 1725.80 19 14.30 2771 2 4
4 13 1133.00 19 14.45 1968 2 5
5 13 414.60 19 14.73 955 2 4
6 8 0.00 170 14.86 342 2 10

Cycle 225 GMT 15/11/2022 18:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 29 14.81 516 2 2
2 7 2006.24 43 14.30 3138 2 4
3 13 1590.84 19 14.32 2597 2 5
4 13 1027.48 19 14.49 1827 2 4
5 13 457.64 19 14.71 1013 2 4
6 8 -0.04 170 14.86 342 2 9

Cycle 224 GMT 5/11/2022 19: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 14.82 510 2 2
2 7 2008.60 43 14.30 3135 2 3
3 13 1482.64 19 14.36 2447 2 6
4 13 1072.88 19 14.46 1873 2 5
5 13 362.48 19 14.75 874 2 4
6 13 20.84 19 14.90 377 2 3
7 8 0.20 170 14.85 336 2 10

Cycle 223 GMT 26/10/2022 19: 3:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 14.82 509 2 2
2 3 1024.84 1 15.01 1857 2 2
3 7 2003.48 44 14.30 3143 2 2
4 13 1584.36 19 14.32 2578 2 5
5 13 899.32 19 14.54 1643 2 4
6 13 342.12 19 14.76 860 2 4
7 8 -0.12 170 14.86 348 2 10

Cycle 222 GMT 16/10/2022 19:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 28 15.00 513 2 2
2 7 2003.96 43 14.30 3135 2 3
3 13 1727.60 19 14.29 2786 2 4
4 13 1138.20 19 14.45 1977 2 7
5 13 412.40 19 14.73 959 2 4
6 8 0.36 170 14.86 352 2 16

Cycle 221 GMT 6/10/2022 17:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 28 14.99 516 2 2
2 7 2007.92 43 14.30 3133 2 3
3 13 1613.16 19 14.32 2626 2 3
4 13 1054.92 19 14.48 1853 2 5
5 13 488.64 19 14.70 1055 2 5
6 8 0.00 170 14.86 353 2 5

Cycle 220 GMT 26/ 9/2022 16:26:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 28 14.98 500 2 2
2 7 2005.16 43 14.30 3142 2 2
3 13 1602.00 19 14.32 2599 2 6
4 13 1031.88 19 14.48 1826 2 7
5 13 460.36 19 14.70 1006 2 4
6 8 0.12 170 14.85 343 2 14

Cycle 219 GMT 16/ 9/2022 14:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 14.82 494 2 2
2 7 2005.08 43 14.30 3135 2 3
3 13 1584.72 19 14.33 2588 2 4
4 13 1157.28 19 14.43 2001 2 4
5 13 423.56 19 14.72 953 2 3
6 8 0.04 170 14.85 341 2 9

Cycle 218 GMT 6/ 9/2022 15:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 15.00 496 2 2
2 7 2007.28 43 14.30 3137 2 3
3 13 1726.36 19 14.29 2770 2 4
4 13 1142.96 19 14.44 1979 2 7
5 13 548.68 19 14.67 1133 2 4
6 8 0.44 170 14.86 340 2 8

Cycle 217 GMT 27/ 8/2022 13:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 15.00 502 2 2
2 7 2008.12 43 14.30 3144 2 2
3 13 1603.44 19 14.32 2624 2 5
4 13 1037.20 19 14.48 1832 2 3
5 13 461.84 19 14.71 1015 2 3
6 8 0.16 170 14.85 342 2 11

Cycle 216 GMT 17/ 8/2022 12:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 15.01 502 2 2
2 7 2005.76 43 14.30 3137 2 2
3 13 1594.44 19 14.33 2597 2 4
4 13 1036.36 19 14.48 1832 2 4
5 13 462.00 19 14.71 1018 2 4
6 13 66.36 19 14.88 449 2 3
7 8 -0.28 170 14.84 339 2 19

Cycle 215 GMT 7/ 8/2022 11: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 29 14.82 501 2 2
2 7 2004.76 43 14.30 3136 2 3
3 13 1593.64 19 14.33 2584 2 5
4 13 1035.76 19 14.48 1824 2 4
5 13 336.60 19 14.77 836 2 3
6 13 19.72 19 14.91 374 2 3
7 8 -0.20 170 14.85 336 2 12

Cycle 214 GMT 28/ 7/2022 11: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 29 14.83 495 2 2
2 7 2008.16 43 14.30 3141 2 2
3 13 1601.32 19 14.32 2608 2 3
4 13 1035.12 19 14.49 1824 2 7
5 13 456.40 19 14.71 1003 2 3
6 8 -0.04 170 14.86 335 2 12

Cycle 213 GMT 18/ 7/2022 11:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 14.83 488 2 2
2 7 2002.60 43 14.31 3128 2 2
3 13 1590.00 19 14.33 2597 2 3
4 13 1043.52 19 14.48 1840 2 5
5 13 465.24 19 14.71 1015 2 4
6 8 0.32 170 14.87 324 2 6

Cycle 212 GMT 8/ 7/2022 11:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 29 14.83 494 2 2
2 7 2004.20 43 14.31 3138 2 3
3 13 1597.76 19 14.33 2609 2 5
4 13 1042.48 19 14.48 1835 2 6
5 13 469.88 19 14.72 1028 2 3
6 13 36.48 19 14.91 392 2 3
7 8 0.12 170 14.87 327 2 12

Cycle 211 GMT 28/ 6/2022 12:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 29 14.85 481 2 2
2 7 2002.68 43 14.31 3134 2 3
3 13 1596.76 19 14.33 2605 2 5
4 13 1035.92 19 14.48 1831 2 3
5 13 454.24 19 14.72 1006 2 3
6 8 0.36 170 14.87 333 2 8

Cycle 210 GMT 18/ 6/2022 12:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 29 14.84 487 2 2
2 7 2004.64 43 14.31 3137 2 3
3 13 1600.52 19 14.33 2608 2 4
4 13 1167.84 19 14.43 2019 2 4
5 13 322.48 19 14.80 805 2 3
6 13 18.76 19 14.93 364 2 2
7 8 -0.28 170 14.88 324 2 12

Cycle 209 GMT 8/ 6/2022 12:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 15.01 489 2 2
2 7 2005.88 43 14.31 3133 2 2
3 13 1595.68 19 14.33 2604 2 5
4 13 1163.68 19 14.43 2007 2 8
5 13 433.12 19 14.74 975 2 3
6 8 0.24 170 14.88 333 2 8

Cycle 208 GMT 29/ 5/2022 11:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 29 14.86 483 2 2
2 7 2006.44 43 14.31 3145 2 3
3 13 1589.16 19 14.33 2604 2 3
4 13 1159.88 19 14.43 2012 2 4
5 13 441.48 19 14.74 976 2 3
6 13 13.28 19 14.92 356 2 2
7 8 0.08 170 14.87 326 2 9

Cycle 207 GMT 19/ 5/2022 12:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 29 15.00 483 2 2
2 7 2002.48 44 14.30 3140 2 2
3 13 1721.64 19 14.29 2778 2 4
4 13 1267.60 19 14.39 2149 2 5
5 13 382.24 19 14.78 886 2 3
6 8 0.24 170 14.89 324 2 6

Cycle 206 GMT 9/ 5/2022 11:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 30 15.06 484 2 2
2 7 2004.92 43 14.31 3138 2 2
3 13 1604.00 19 14.32 2610 2 4
4 13 1051.56 19 14.48 1854 2 6
5 13 345.80 19 14.80 838 2 2
6 8 0.08 170 14.89 321 2 8

Cycle 205 GMT 29/ 4/2022 10:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 30 14.92 474 2 2
2 7 2008.32 43 14.31 3144 2 2
3 13 1732.28 19 14.29 2780 2 3
4 13 1151.44 19 14.44 1991 2 4
5 13 436.52 19 14.75 964 2 2
6 13 58.92 19 14.91 417 2 2
7 8 0.00 170 14.88 320 2 14
8 14 0.00 20 14.85 321 2 9

Cycle 204 GMT 19/ 4/2022 10:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 29 14.86 484 2 2
2 7 2004.40 43 14.31 3144 2 2
3 13 1730.96 19 14.30 2780 2 3
4 13 1033.52 19 14.49 1821 2 6
5 13 333.36 19 14.80 814 2 2
6 13 37.96 19 14.93 382 2 2
7 8 0.20 170 14.88 319 2 10

Cycle 203 GMT 9/ 4/2022 10:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 14.86 484 2 2
2 7 2009.36 43 14.32 3148 2 2
3 13 1612.00 19 14.32 2625 2 3
4 13 1054.48 19 14.47 1861 2 3
5 13 479.08 19 14.73 1035 2 3
6 8 -0.04 170 14.89 325 2 7

Cycle 202 GMT 30/ 3/2022 11:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 14.95 486 2 2
2 7 2001.64 43 14.32 3140 2 2
3 13 1727.40 19 14.31 2774 2 3
4 13 1139.60 19 14.44 1974 2 5
5 13 426.00 19 14.76 953 2 3
6 8 0.40 170 14.89 323 2 7

Cycle 201 GMT 20/ 3/2022 11: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 29 14.85 479 2 2
2 7 2002.32 43 14.32 3144 2 2
3 13 1728.12 19 14.30 2791 2 3
4 13 1147.48 19 14.44 1989 2 3
5 13 562.48 19 14.68 1161 2 3
6 13 47.84 19 14.91 409 2 3
7 8 0.16 170 14.87 325 2 12

Cycle 200 GMT 10/ 3/2022 11:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 30 15.08 474 2 2
2 7 2004.08 43 14.31 3144 2 2
3 13 1605.04 19 14.32 2613 2 3
4 13 1049.32 19 14.47 1850 2 5
5 13 338.00 19 14.79 829 2 3
6 8 0.28 170 14.88 325 2 6

Cycle 199 GMT 28/ 2/2022 10:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.85 482 2 2
2 7 2003.84 43 14.32 3144 2 2
3 13 1729.64 19 14.30 2778 2 5
4 13 1161.68 19 14.43 1999 2 4
5 13 445.36 19 14.75 983 2 3
6 8 0.28 170 14.89 323 2 5

Cycle 198 GMT 18/ 2/2022 10:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 14.86 468 2 2
2 7 2002.44 43 14.32 3147 2 2
3 13 1731.04 19 14.30 2789 2 3
4 13 1023.92 19 14.49 1815 2 2
5 13 321.64 19 14.81 805 2 2
6 13 34.40 19 14.92 386 2 2
7 8 0.08 170 14.88 323 2 11

Cycle 197 GMT 8/ 2/2022 11:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 30 15.03 465 2 2
2 7 2002.84 43 14.32 3138 2 2
3 13 1600.88 19 14.32 2609 2 3
4 13 1173.04 19 14.42 2014 2 5
5 13 313.76 19 14.81 788 2 3
6 8 0.08 170 14.88 323 2 7

Cycle 196 GMT 29/ 1/2022 10:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 29 14.87 470 2 2
2 7 2004.40 43 14.32 3145 2 2
3 13 1602.64 19 14.33 2616 2 4
4 13 1179.44 19 14.42 2038 2 6
5 13 442.32 19 14.75 982 2 3
6 8 0.04 170 14.88 323 2 9

Cycle 195 GMT 19/ 1/2022 11: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 14.86 462 2 2
2 7 2005.04 44 14.31 3145 2 2
3 13 1591.24 19 14.33 2596 2 2
4 13 1035.08 19 14.48 1832 2 6
5 13 325.36 19 14.80 807 2 3
6 8 -0.24 170 14.88 322 2 5

Cycle 194 GMT 9/ 1/2022 11:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 15.09 458 2 2
2 7 2003.04 43 14.32 3139 2 2
3 13 1601.72 19 14.32 2603 2 3
4 13 1171.48 19 14.43 2015 2 3
5 13 439.24 19 14.75 965 2 2
6 8 0.40 170 14.89 315 2 7

Cycle 193 GMT 30/12/2021 10:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 29 15.08 472 2 2
2 7 2003.80 43 14.32 3134 2 2
3 13 1594.92 19 14.33 2602 2 4
4 13 1052.52 19 14.47 1856 2 5
5 13 476.76 19 14.73 1019 2 3
6 8 -0.04 170 14.88 320 2 5

Cycle 192 GMT 20/12/2021 8:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 29 14.86 459 2 2
2 7 2001.88 43 14.33 3148 2 2
3 13 1728.12 19 14.31 2775 2 4
4 13 1145.80 19 14.44 1984 2 4
5 13 557.52 19 14.69 1137 2 2
6 8 0.16 170 14.88 320 2 6

Cycle 191 GMT 10/12/2021 9:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 29 15.08 467 2 2
2 7 2006.44 43 14.32 3150 2 3
3 13 1736.04 19 14.30 2787 2 3
4 13 1032.84 19 14.48 1819 2 5
5 13 334.92 19 14.80 817 2 2
6 8 0.04 170 14.89 319 2 9

Cycle 190 GMT 30/11/2021 8:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 29 15.07 461 2 2
2 7 2004.44 44 14.32 3140 2 3
3 13 1594.80 19 14.33 2596 2 4
4 13 1019.68 19 14.48 1808 2 5
5 13 445.64 19 14.74 986 2 3
6 8 0.12 170 14.88 322 2 9

Cycle 189 GMT 20/11/2021 7: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 15.06 467 2 2
2 7 2003.60 43 14.32 3145 2 2
3 13 1595.20 19 14.34 2597 2 3
4 13 1166.96 19 14.42 2012 2 3
5 13 420.60 19 14.75 945 2 2
6 8 0.00 170 14.88 323 2 8

Cycle 188 GMT 10/11/2021 5:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 15.06 468 2 2
2 7 2002.60 43 14.33 3138 2 2
3 13 1598.64 19 14.33 2594 2 3
4 13 1174.32 19 14.42 2018 2 3
5 13 457.04 19 14.74 995 2 2
6 8 0.20 170 14.88 321 2 6

Cycle 187 GMT 31/10/2021 4:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 29 15.06 475 2 2
2 7 2004.88 43 14.33 3141 2 2
3 13 1599.88 19 14.33 2603 2 4
4 13 1047.12 19 14.48 1844 2 5
5 13 485.56 19 14.73 1031 2 3
6 8 0.28 170 14.88 323 2 7

Cycle 186 GMT 21/10/2021 3:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 29 15.06 471 2 2
2 7 2007.36 43 14.33 3143 2 2
3 13 1728.80 19 14.31 2780 2 3
4 13 1157.44 19 14.44 1995 2 6
5 13 436.84 19 14.75 966 2 2
6 8 0.16 170 14.88 330 2 10

Cycle 185 GMT 11/10/2021 1:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 29 15.06 470 2 2
2 7 2009.28 43 14.33 3146 2 3
3 13 1601.12 19 14.33 2600 2 5
4 13 1171.88 19 14.43 2016 2 4
5 13 303.04 19 14.81 770 2 2
6 8 0.24 170 14.88 320 2 9

Cycle 184 GMT 1/10/2021 0:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 29 14.85 498 2 2
2 7 2003.40 43 14.33 3146 2 2
3 13 1594.80 19 14.34 2608 2 5
4 13 1167.00 19 14.42 2011 2 5
5 13 313.64 19 14.81 794 2 2
6 8 -0.28 170 14.88 323 2 9

Cycle 183 GMT 21/ 9/2021 1: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 29 15.05 487 2 2
2 7 2003.44 43 14.33 3137 2 2
3 13 1602.48 19 14.34 2609 2 3
4 13 1045.88 19 14.48 1845 2 4
5 13 336.56 19 14.80 829 2 2
6 8 0.08 170 14.88 330 2 10

Cycle 182 GMT 10/ 9/2021 23:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 29 15.06 492 2 2
2 7 2003.36 43 14.34 3142 2 2
3 13 1603.80 19 14.34 2614 2 5
4 13 1174.68 19 14.42 2025 2 3
5 13 446.52 19 14.74 981 2 2
6 8 0.52 170 14.87 327 2 9

Cycle 181 GMT 31/ 8/2021 22:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 29 15.06 490 2 2
2 7 2005.76 43 14.33 3147 2 2
3 13 1611.08 19 14.33 2620 2 4
4 13 1058.76 19 14.47 1862 2 4
5 13 346.76 19 14.79 835 2 2
6 8 -0.36 170 14.88 324 2 15

Cycle 180 GMT 21/ 8/2021 21: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 29 14.83 482 2 2
2 7 2006.72 43 14.34 3141 2 2
3 13 1736.88 19 14.31 2791 2 5
4 13 1024.12 19 14.49 1814 2 5
5 13 448.00 19 14.75 990 2 3
6 8 0.08 170 14.88 333 2 17

Cycle 179 GMT 11/ 8/2021 21:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 14.86 494 2 2
2 7 2005.40 43 14.34 3140 2 2
3 13 1729.80 19 14.32 2780 2 2
4 13 1143.44 19 14.44 1993 2 4
5 13 296.16 19 14.82 782 2 2
6 13 72.28 19 14.91 445 2 2
7 8 0.12 170 14.88 328 2 10

Cycle 178 GMT 1/ 8/2021 21:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 14.93 483 2 2
2 7 2007.00 43 14.34 3146 2 3
3 13 1741.60 19 14.32 2795 2 3
4 13 1024.00 19 14.49 1824 2 5
5 13 453.44 19 14.75 997 2 2
6 8 0.24 170 14.89 327 2 4

Cycle 177 GMT 22/ 7/2021 21:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 15.07 486 2 2
2 7 2003.20 43 14.33 3141 2 2
3 13 1873.88 19 14.29 2981 2 3
4 13 1842.92 19 14.21 2936 2 3
5 13 478.28 19 14.74 1035 2 2
6 8 2.68 170 14.89 330 2 9
7 14 2.68 20 14.86 329 2 6

Cycle 176 GMT 12/ 7/2021 20:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 29 14.91 486 2 2
2 7 2003.16 43 14.33 3153 2 2
3 13 1729.68 19 14.32 2785 2 3
4 13 1027.08 19 14.49 1829 2 3
5 13 326.84 19 14.81 818 2 3
6 8 -0.20 170 14.89 327 2 5

Cycle 175 GMT 2/ 7/2021 20:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 29 15.06 483 2 2
2 7 2010.28 43 14.34 3139 2 2
3 13 1606.68 19 14.34 2623 2 3
4 13 1049.68 19 14.47 1858 2 3
5 13 337.12 19 14.79 824 2 2
6 8 -0.16 170 14.88 323 2 7

Cycle 174 GMT 22/ 6/2021 18:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 15.08 471 2 2
2 7 2002.24 43 14.34 3135 2 2
3 13 1595.40 19 14.34 2601 2 3
4 13 1167.12 19 14.42 2004 2 4
5 13 431.72 19 14.74 963 2 2
6 8 0.40 170 14.88 324 2 6

Cycle 173 GMT 12/ 6/2021 17:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 29 14.91 477 2 2
2 7 2004.92 43 14.35 3136 2 2
3 13 1609.00 19 14.35 2609 2 3
4 13 1045.08 19 14.48 1836 2 4
5 13 345.60 19 14.79 835 2 2
6 8 0.00 170 14.88 322 2 5

Cycle 172 GMT 2/ 6/2021 17:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 29 15.08 480 2 2
2 7 2007.20 43 14.34 3137 2 2
3 13 1593.48 19 14.35 2605 2 5
4 13 1050.20 19 14.48 1844 2 5
5 13 339.72 19 14.79 826 2 2
6 13 17.32 19 14.93 351 2 2
7 8 0.12 170 14.87 319 2 12

Cycle 171 GMT 23/ 5/2021 16:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 29 14.86 472 2 2
2 7 2002.56 43 14.34 3131 2 2
3 13 1590.32 19 14.35 2583 2 3
4 13 1037.24 19 14.49 1824 2 4
5 13 454.64 19 14.74 988 2 2
6 8 -0.12 170 14.88 320 2 6

Cycle 170 GMT 13/ 5/2021 16:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 29 15.10 463 2 2
2 7 2002.92 44 14.33 3140 2 2
3 13 1595.92 19 14.34 2596 2 4
4 13 1027.68 19 14.48 1816 2 3
5 13 312.48 19 14.80 786 2 2
6 8 0.12 170 14.88 317 2 8

Cycle 169 GMT 3/ 5/2021 15:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 14.88 466 2 2
2 7 2007.40 43 14.34 3142 2 3
3 13 1732.72 19 14.33 2784 2 4
4 13 1021.84 19 14.50 1799 2 6
5 13 314.16 19 14.81 785 2 2
6 8 0.08 170 14.89 316 2 7

Cycle 168 GMT 23/ 4/2021 15:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 29 14.87 470 2 2
2 7 2009.72 43 14.35 3147 2 2
3 13 1598.52 19 14.36 2598 2 3
4 13 1050.12 19 14.48 1845 2 3
5 13 339.60 19 14.80 824 2 2
6 8 0.04 170 14.90 312 2 9

Cycle 167 GMT 13/ 4/2021 16:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 29 14.86 460 2 2
2 7 2003.12 44 14.34 3135 2 2
3 13 1588.32 19 14.35 2581 2 3
4 13 1033.36 19 14.49 1827 2 2
5 13 323.32 19 14.81 799 2 2
6 13 17.92 19 14.93 347 2 2
7 8 -0.12 170 14.88 315 2 3
8 14 -0.12 20 14.85 313 2 15

Cycle 166 GMT 3/ 4/2021 16:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 29 15.13 443 2 2
2 7 2008.28 43 14.34 3137 2 2
3 13 1597.68 19 14.34 2599 2 3
4 13 1037.68 19 14.47 1831 2 3
5 13 327.16 19 14.80 806 2 2
6 8 0.36 170 14.88 314 2 5

Cycle 165 GMT 24/ 3/2021 15: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 29 14.88 459 2 2
2 7 2002.72 43 14.35 3149 2 2
3 13 1592.44 19 14.35 2610 2 3
4 13 1043.96 19 14.49 1844 2 5
5 13 457.12 19 14.75 988 2 3
6 8 0.04 170 14.89 311 2 4

Cycle 164 GMT 14/ 3/2021 15:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 14.88 456 2 2
2 7 2007.60 43 14.35 3144 2 2
3 13 1732.20 19 14.33 2782 2 2
4 13 1033.24 19 14.50 1822 2 4
5 13 450.16 19 14.76 977 2 2
6 8 0.24 170 14.90 306 2 7

Cycle 163 GMT 4/ 3/2021 15:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.13 436 2 2
2 7 2002.88 43 14.35 3130 2 2
3 13 1599.52 19 14.36 2588 2 4
4 13 1165.36 19 14.43 2009 2 4
5 13 433.96 19 14.75 968 2 2
6 8 0.00 170 14.89 312 2 6

Cycle 162 GMT 22/ 2/2021 14:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 29 15.14 440 2 2
2 7 2002.04 43 14.35 3130 2 3
3 13 1594.52 19 14.36 2593 2 4
4 13 1036.72 19 14.49 1822 2 4
5 13 460.08 19 14.74 998 2 2
6 8 0.20 170 14.89 310 2 5

Cycle 161 GMT 12/ 2/2021 13:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 14.88 448 2 2
2 7 2003.56 43 14.36 3124 2 2
3 13 1600.12 19 14.36 2593 2 3
4 13 1046.00 19 14.49 1846 2 4
5 13 204.08 19 14.87 621 2 2
6 8 -0.04 170 14.90 309 2 4

Cycle 160 GMT 2/ 2/2021 13:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 29 15.15 433 2 2
2 7 2006.60 43 14.35 3133 2 2
3 13 1601.40 19 14.35 2594 2 5
4 13 1047.68 19 14.48 1834 2 5
5 13 338.48 19 14.80 814 2 2
6 8 0.12 170 14.89 307 2 4

Cycle 159 GMT 23/ 1/2021 12:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 14.88 458 2 2
2 7 2002.88 43 14.36 3131 2 3
3 13 1474.56 19 14.39 2433 2 5
4 13 1068.12 19 14.47 1871 2 5
5 13 485.88 19 14.73 1028 2 3
6 8 -0.20 170 14.90 307 2 6

Cycle 158 GMT 13/ 1/2021 12:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 15.13 441 2 2
2 7 2005.36 43 14.35 3132 2 2
3 13 1723.60 19 14.34 2768 2 3
4 13 1014.56 19 14.50 1798 2 5
5 13 445.00 19 14.75 974 2 2
6 8 0.12 170 14.90 310 2 3

Cycle 157 GMT 3/ 1/2021 11:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 29 14.88 456 2 2
2 7 2006.68 43 14.36 3132 2 3
3 13 1725.52 19 14.34 2762 2 4
4 13 1026.68 19 14.51 1802 2 3
5 13 456.00 19 14.76 981 2 2
6 8 0.36 170 14.91 309 2 4

Cycle 156 GMT 24/12/2020 11:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 14.87 458 2 2
2 7 2007.56 43 14.36 3127 2 3
3 13 1606.08 19 14.37 2599 2 5
4 13 1051.08 19 14.49 1841 2 5
5 13 336.32 19 14.81 815 2 2
6 8 -0.12 170 14.90 311 2 7

Cycle 155 GMT 14/12/2020 11:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 29 15.13 457 2 2
2 7 2002.92 44 14.35 3132 2 2
3 13 1584.52 19 14.37 2585 2 4
4 13 1019.20 19 14.50 1803 2 5
5 13 421.80 19 14.76 934 2 2
6 8 0.20 170 14.89 314 2 9

Cycle 154 GMT 4/12/2020 10:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 29 14.89 469 2 2
2 7 2002.92 43 14.36 3122 2 3
3 13 1594.44 19 14.37 2588 2 4
4 13 1036.24 19 14.50 1818 2 4
5 13 457.48 19 14.75 1000 2 2
6 13 17.88 19 14.94 347 2 2
7 8 0.24 170 14.90 317 2 4

Cycle 153 GMT 24/11/2020 10:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 29 14.87 458 2 2
2 3 1021.92 1 15.12 1818 2 2
3 7 2003.56 43 14.36 3125 2 2
4 13 1604.08 19 14.37 2602 2 2
5 13 1044.76 19 14.50 1825 2 3
6 13 463.84 19 14.76 991 2 2
7 8 0.08 170 14.91 311 2 10
8 14 0.08 20 14.88 314 2 5

Cycle 152 GMT 14/11/2020 11:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 28 15.15 435 2 2
2 7 2007.00 44 14.34 3146 2 2
3 13 1596.40 19 14.36 2606 2 2
4 13 1028.20 19 14.49 1811 2 3
5 13 453.12 19 14.75 981 2 2
6 8 -0.16 170 14.89 312 2 6

Cycle 151 GMT 4/11/2020 9:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 28 15.15 435 2 2
2 7 2007.44 43 14.36 3139 2 2
3 13 1593.44 19 14.37 2585 2 3
4 13 1165.48 19 14.44 2000 2 5
5 13 428.68 19 14.77 950 2 2
6 13 81.36 19 14.92 433 2 2
7 8 0.36 170 14.90 307 2 6

Cycle 150 GMT 25/10/2020 8:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 29 15.14 439 2 2
2 7 2004.04 44 14.35 3118 2 3
3 13 1590.48 19 14.36 2581 2 4
4 13 1030.08 19 14.50 1815 2 6
5 13 306.28 19 14.83 769 2 3
6 8 0.00 170 14.91 306 2 4

Cycle 149 GMT 15/10/2020 7:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 29 15.13 446 2 2
2 7 2004.76 44 14.36 3123 2 2
3 13 1593.84 19 14.37 2590 2 5
4 13 1023.76 19 14.50 1807 2 3
5 13 310.16 19 14.82 781 2 2
6 8 -0.08 170 14.90 315 2 6

Cycle 148 GMT 5/10/2020 5:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 29 15.10 476 2 2
2 7 2006.36 43 14.36 3127 2 2
3 13 1583.52 19 14.37 2579 2 4
4 13 1031.12 19 14.50 1821 2 5
5 13 317.56 19 14.82 797 2 3
6 8 0.12 170 14.90 316 2 7

Cycle 147 GMT 25/ 9/2020 4:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.89 476 2 2
2 7 2004.40 43 14.37 3129 2 2
3 13 1594.68 19 14.38 2610 2 3
4 13 1162.08 19 14.45 2002 2 4
5 13 306.72 19 14.83 790 2 2
6 8 0.20 170 14.90 328 2 7

Cycle 146 GMT 15/ 9/2020 4:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 29 15.13 442 2 2
2 7 2004.00 43 14.37 3122 2 2
3 13 1736.32 19 14.35 2775 2 3
4 13 1152.72 19 14.46 1978 2 6
5 13 424.64 19 14.78 942 2 2
6 8 0.32 170 14.91 312 2 6

Cycle 145 GMT 5/ 9/2020 3:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 15.15 447 2 2
2 7 2006.32 43 14.37 3136 2 2
3 13 1734.52 19 14.35 2778 2 2
4 13 1023.60 19 14.52 1788 2 4
5 13 455.32 19 14.77 981 2 2
6 8 0.36 170 14.91 307 2 7

Cycle 144 GMT 26/ 8/2020 2: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 29 14.87 455 2 2
2 7 2004.96 43 14.37 3137 2 2
3 13 1723.56 19 14.36 2765 2 3
4 13 1132.60 19 14.48 1947 2 6
5 13 408.32 19 14.80 915 2 2
6 8 0.28 170 14.92 302 2 6

Cycle 143 GMT 16/ 8/2020 2:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 14.88 445 2 2
2 7 2008.20 43 14.37 3137 2 3
3 13 1479.60 19 14.41 2436 2 3
4 13 1066.60 19 14.49 1865 2 2
5 13 215.72 19 14.87 639 2 2
6 8 -0.16 170 14.91 311 2 5

Cycle 142 GMT 6/ 8/2020 2:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 15.13 439 2 2
2 7 2005.52 43 14.36 3132 2 2
3 13 1597.72 19 14.38 2587 2 4
4 13 916.12 19 14.57 1639 2 3
5 13 358.72 19 14.81 844 2 2
6 8 0.36 170 14.91 307 2 6

Cycle 141 GMT 27/ 7/2020 1: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 15.13 462 2 2
2 7 2004.56 43 14.38 3136 2 2
3 13 1598.88 19 14.38 2589 2 5
4 13 1166.12 19 14.46 2008 2 5
5 13 441.76 19 14.77 960 2 2
6 8 0.52 170 14.91 306 2 8

Cycle 140 GMT 16/ 7/2020 23:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 29 14.88 453 2 2
2 7 2006.68 44 14.38 3131 2 2
3 13 1588.48 19 14.39 2584 2 3
4 13 894.88 19 14.59 1617 2 4
5 13 330.72 19 14.83 807 2 3
6 8 -0.04 170 14.91 308 2 8

Cycle 139 GMT 7/ 7/2020 0:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 29 15.15 447 2 2
2 7 2007.04 44 14.37 3137 2 2
3 13 1589.64 19 14.38 2583 2 3
4 13 1028.52 19 14.51 1816 2 5
5 13 326.36 19 14.82 801 2 2
6 8 0.24 170 14.91 310 2 4

Cycle 138 GMT 26/ 6/2020 22:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 29 15.15 441 2 2
2 7 2003.88 42 14.39 3125 2 3
3 13 1732.00 21 14.35 2777 2 3
4 13 1010.24 21 14.53 1785 2 4
5 13 295.60 21 14.85 751 2 2
6 8 0.28 170 14.92 312 2 3

Cycle 137 GMT 16/ 6/2020 21:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 14.90 451 2 2
2 3 1025.24 1 15.13 1812 2 2
3 7 2007.48 42 14.39 3145 2 2
4 13 1604.52 21 14.38 2606 2 3
5 13 1167.56 21 14.46 2005 2 2
6 13 267.88 21 14.85 717 2 2
7 8 -0.24 170 14.91 310 2 7

Cycle 136 GMT 6/ 6/2020 21:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 28 15.17 452 2 2
2 7 2008.92 41 14.37 3147 2 2
3 13 1736.44 21 14.35 2789 2 2
4 13 1013.80 21 14.53 1784 2 3
5 13 160.32 21 14.91 568 2 2
6 8 0.12 170 14.93 313 2 8

Cycle 135 GMT 27/ 5/2020 20: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 29 15.16 450 2 2
2 7 2004.20 42 14.38 3133 2 2
3 13 1721.76 21 14.35 2758 2 4
4 13 1009.40 21 14.53 1794 2 3
5 13 162.04 21 14.91 569 2 2
6 8 -0.04 170 14.93 311 2 6

Cycle 134 GMT 17/ 5/2020 18:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 29 14.90 458 2 2
2 7 2003.16 41 14.39 3134 2 2
3 13 1736.20 21 14.35 2771 2 4
4 13 1013.80 21 14.54 1794 2 5
5 13 293.52 21 14.85 753 2 2
6 8 0.16 170 14.93 308 2 3

Cycle 133 GMT 7/ 5/2020 18:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 28 14.92 447 2 2
2 3 1019.52 1 15.14 1813 2 2
3 7 2004.12 41 14.38 3132 2 3
4 13 1598.64 21 14.38 2602 2 3
5 13 1035.00 21 14.51 1830 2 5
6 13 170.92 21 14.90 581 2 2
7 8 0.12 170 14.92 308 2 6

Cycle 132 GMT 27/ 4/2020 19: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 28 15.19 427 2 2
2 7 2008.04 41 14.39 3136 2 3
3 13 1616.96 21 14.38 2616 2 3
4 13 1069.88 21 14.50 1858 2 6
5 13 208.76 21 14.90 615 2 2
6 8 0.20 170 14.94 299 2 5

Cycle 131 GMT 17/ 4/2020 17:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 29 15.20 430 2 2
2 7 2006.32 41 14.38 3122 2 2
3 13 1726.08 21 14.36 2758 2 4
4 13 1010.68 21 14.53 1780 2 3
5 13 161.68 21 14.92 554 2 2
6 8 0.20 170 14.94 299 2 5

Cycle 130 GMT 7/ 4/2020 16: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 29 14.92 450 2 2
2 7 2002.96 41 14.39 3127 2 2
3 13 1734.44 21 14.37 2769 2 2
4 13 1148.44 21 14.48 1980 2 5
5 13 275.72 21 14.87 717 2 2
6 8 0.12 170 14.94 300 2 5

Cycle 129 GMT 28/ 3/2020 16:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 14.93 456 2 2
2 3 1026.76 1 15.12 1849 2 2
3 7 2004.44 41 14.39 3129 2 3
4 13 1727.60 21 14.36 2758 2 3
5 13 1012.96 21 14.54 1792 2 3
6 13 283.72 21 14.87 741 2 2
7 8 0.04 170 14.94 304 2 6

Cycle 128 GMT 18/ 3/2020 16:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 28 15.20 424 2 2
2 7 2004.40 41 14.37 3138 2 3
3 13 1594.20 21 14.38 2586 2 5
4 13 1023.64 21 14.52 1801 2 5
5 13 286.88 21 14.85 735 2 2
6 8 0.24 170 14.93 299 2 4

Cycle 127 GMT 8/ 3/2020 15:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 28 15.20 431 2 2
2 7 2008.24 41 14.37 3137 2 2
3 13 1602.32 21 14.38 2601 2 2
4 13 1037.52 21 14.52 1830 2 5
5 13 176.16 21 14.91 588 2 2
6 8 0.24 170 14.94 304 2 4

Cycle 126 GMT 27/ 2/2020 13:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 28 15.20 423 2 2
2 7 2002.76 41 14.38 3128 2 2
3 13 1727.20 21 14.36 2761 2 3
4 13 1008.88 21 14.54 1777 2 4
5 13 156.68 21 14.93 545 2 2
6 8 -0.16 170 14.94 300 2 9

Cycle 125 GMT 17/ 2/2020 12:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 15.20 422 2 2
2 7 2003.00 42 14.38 3125 2 2
3 13 1609.36 21 14.38 2607 2 4
4 13 1042.72 21 14.52 1828 2 5
5 13 180.24 21 14.91 582 2 2
6 8 -0.08 170 14.94 302 2 6

Cycle 124 GMT 7/ 2/2020 10:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 29 14.93 447 2 2
2 7 2002.40 41 14.39 3126 2 3
3 13 1601.36 21 14.39 2584 2 5
4 13 1021.16 21 14.53 1803 2 4
5 13 278.32 21 14.86 728 2 2
6 13 24.16 21 14.97 341 2 2
7 8 -0.08 170 14.93 300 2 8

Cycle 123 GMT 28/ 1/2020 11:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 29 14.93 445 2 2
2 7 2006.68 41 14.39 3134 2 2
3 13 1729.36 21 14.37 2773 2 3
4 13 998.84 21 14.55 1770 2 3
5 13 143.80 21 14.94 525 2 2
6 8 0.08 170 14.95 307 2 3

Cycle 122 GMT 18/ 1/2020 11:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 29 14.93 446 2 2
2 7 2005.24 41 14.39 3125 2 2
3 13 1590.80 21 14.40 2588 2 4
4 13 1016.24 21 14.54 1790 2 6
5 13 159.16 21 14.93 552 2 2
6 8 0.12 170 14.95 307 2 5

Cycle 121 GMT 8/ 1/2020 11:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 29 15.00 443 2 2
2 7 2004.52 42 14.39 3129 2 3
3 13 1598.76 21 14.40 2588 2 4
4 13 1034.96 21 14.53 1823 2 4
5 13 173.80 21 14.92 579 2 2
6 8 0.08 170 14.95 305 2 6

Cycle 120 GMT 29/12/2019 11:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 29 14.93 447 2 2
2 7 2004.24 41 14.39 3135 2 3
3 13 1600.32 21 14.40 2600 2 5
4 13 1022.68 21 14.53 1802 2 3
5 13 165.72 21 14.93 562 2 2
6 8 0.12 170 14.94 308 2 5

Cycle 119 GMT 19/12/2019 11:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 28 14.94 464 2 2
2 7 2008.56 41 14.39 3123 2 2
3 13 1610.52 21 14.40 2619 2 3
4 13 1033.72 21 14.53 1826 2 4
5 13 163.44 21 14.93 564 2 2
6 8 -0.20 170 14.94 308 2 4

Cycle 118 GMT 9/12/2019 11:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 14.93 456 2 2
2 7 2002.00 41 14.40 3128 2 2
3 13 1724.48 21 14.37 2762 2 5
4 13 995.68 21 14.56 1768 2 5
5 13 131.16 21 14.96 511 2 2
6 8 0.08 170 14.96 307 2 5

Cycle 117 GMT 29/11/2019 11:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 28 15.17 451 2 2
2 7 2004.24 42 14.39 3131 2 2
3 13 1597.28 21 14.40 2590 2 5
4 13 1028.60 21 14.53 1808 2 5
5 13 77.72 21 14.97 425 2 2
6 8 0.24 170 14.95 303 2 4

Cycle 116 GMT 19/11/2019 10:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 28 14.92 477 2 2
2 7 2003.88 41 14.40 3123 2 2
3 13 1586.32 21 14.41 2583 2 3
4 13 1022.76 21 14.54 1809 2 4
5 13 140.52 21 14.94 537 2 2
6 8 -0.20 170 14.95 315 2 5

Cycle 115 GMT 9/11/2019 10:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 14.91 459 2 2
2 7 2003.20 42 14.41 3135 2 2
3 13 1595.40 21 14.41 2600 2 3
4 13 1027.56 21 14.54 1816 2 5
5 13 162.08 21 14.94 568 2 2
6 8 0.28 170 14.95 316 2 5

Cycle 114 GMT 30/10/2019 10:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 28 14.92 458 2 2
2 7 2004.28 42 14.40 3123 2 2
3 13 1724.48 21 14.39 2770 2 4
4 13 1008.16 21 14.55 1795 2 4
5 13 283.60 21 14.88 747 2 2
6 8 -0.12 170 14.94 316 2 4

Cycle 113 GMT 20/10/2019 11: 5:47

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 28 15.15 472 2 2
2 7 2002.44 41 14.40 3126 2 3
3 13 1599.48 21 14.41 2595 2 4
4 13 1030.40 21 14.54 1813 2 5
5 13 173.44 21 14.93 577 2 2
6 8 0.04 170 14.95 314 2 5

Cycle 112 GMT 10/10/2019 9:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 15.15 470 2 2
2 7 2005.44 41 14.40 3126 2 2
3 13 1605.28 21 14.40 2605 2 3
4 13 1037.16 21 14.54 1830 2 3
5 13 164.44 21 14.93 565 2 2
6 8 0.16 170 14.95 320 2 5

Cycle 111 GMT 30/ 9/2019 7:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 28 14.91 486 2 2
2 7 2007.28 41 14.41 3120 2 2
3 13 1613.60 21 14.41 2629 2 4
4 13 1047.72 21 14.54 1850 2 6
5 13 185.72 21 14.93 595 2 2
6 8 0.20 170 14.95 316 2 6

Cycle 110 GMT 20/ 9/2019 7:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 15.15 456 2 2
2 7 2006.28 42 14.40 3140 2 3
3 13 1599.80 21 14.41 2589 2 3
4 13 1020.04 21 14.55 1803 2 4
5 13 287.80 21 14.88 745 2 2
6 8 0.20 170 14.94 320 2 7

Cycle 109 GMT 10/ 9/2019 6:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 15.08 467 2 2
2 7 2003.32 41 14.41 3124 2 2
3 13 1728.96 21 14.39 2766 2 3
4 13 1005.64 21 14.56 1790 2 4
5 13 161.08 21 14.95 559 2 2
6 8 0.08 170 14.96 315 2 5

Cycle 108 GMT 31/ 8/2019 5:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 28 14.92 485 2 2
2 7 2003.92 41 14.41 3132 2 3
3 13 1728.76 21 14.39 2770 2 2
4 13 1001.00 21 14.57 1772 2 3
5 13 266.00 21 14.90 708 2 2
6 8 -0.12 170 14.95 316 2 8

Cycle 107 GMT 21/ 8/2019 6: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 28 15.16 459 2 2
2 7 2003.40 41 14.41 3115 2 2
3 13 1731.64 21 14.38 2775 2 3
4 13 1003.00 21 14.57 1781 2 6
5 13 272.72 21 14.89 723 2 2
6 8 0.12 170 14.95 315 2 4

Cycle 106 GMT 11/ 8/2019 4:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 28 15.16 451 2 2
2 7 2006.72 41 14.40 3122 2 2
3 13 1592.24 21 14.41 2595 2 3
4 13 1023.84 21 14.55 1808 2 4
5 13 168.96 21 14.94 577 2 2
6 8 0.12 170 14.96 317 2 5

Cycle 105 GMT 1/ 8/2019 3: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 28 14.93 459 2 2
2 7 2003.80 42 14.41 3120 2 2
3 13 1605.28 21 14.41 2598 2 4
4 13 1027.04 21 14.56 1818 2 6
5 13 150.44 21 14.95 550 2 2
6 8 0.40 170 14.96 317 2 7

Cycle 104 GMT 22/ 7/2019 3: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 14.94 469 2 2
2 7 2006.84 42 14.41 3117 2 2
3 13 1589.80 21 14.43 2580 2 3
4 13 1022.56 21 14.56 1808 2 4
5 13 290.20 21 14.89 748 2 2
6 8 0.08 170 14.95 313 2 6

Cycle 103 GMT 12/ 7/2019 3:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 28 15.18 449 2 2
2 7 2007.76 41 14.41 3127 2 2
3 13 1613.64 21 14.41 2603 2 4
4 13 1038.28 21 14.55 1825 2 3
5 13 177.84 21 14.94 590 2 2
6 8 -0.08 170 14.95 314 2 6

Cycle 102 GMT 2/ 7/2019 1:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 28 15.18 448 2 2
2 7 2007.72 41 14.41 3132 2 2
3 13 1602.68 21 14.41 2604 2 3
4 13 1031.32 21 14.55 1814 2 5
5 13 160.32 21 14.95 555 2 2
6 8 0.12 170 14.96 313 2 5

Cycle 101 GMT 22/ 6/2019 0:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 28 14.93 472 2 2
2 7 2002.84 42 14.42 3109 2 2
3 13 1599.40 21 14.43 2594 2 4
4 13 1020.28 21 14.57 1804 2 5
5 13 140.08 21 14.96 527 2 2
6 8 0.20 170 14.96 316 2 10

Cycle 100 GMT 12/ 6/2019 0:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 28 14.94 461 2 2
2 7 2005.20 42 14.41 3114 2 2
3 13 1596.68 21 14.42 2593 2 3
4 13 1027.00 21 14.56 1811 2 5
5 13 283.44 21 14.89 738 2 2
6 8 0.04 170 14.96 313 2 7

Cycle 99 GMT 2/ 6/2019 0:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 28 14.94 452 2 2
2 7 2003.12 42 14.41 3110 2 3
3 13 1602.04 21 14.42 2603 2 3
4 13 1030.44 21 14.56 1810 2 5
5 13 168.76 21 14.95 574 2 2
6 8 0.32 170 14.97 317 2 7

Cycle 98 GMT 23/ 5/2019 0:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 28 14.94 478 2 2
2 7 2003.20 41 14.42 3131 2 2
3 13 1735.44 21 14.39 2780 2 2
4 13 1024.04 21 14.58 1808 2 3
5 13 293.08 21 14.90 755 2 2
6 8 0.08 170 14.97 314 2 11

Cycle 97 GMT 13/ 5/2019 0:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 28 14.95 461 2 2
2 7 2003.72 41 14.41 3130 2 2
3 13 1729.80 21 14.39 2769 2 3
4 13 1135.80 21 14.52 1972 2 3
5 13 252.72 21 14.92 700 2 2
6 8 0.16 170 14.97 319 2 5

Cycle 96 GMT 3/ 5/2019 1: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.95 458 2 2
2 7 2007.92 41 14.41 3135 2 2
3 13 1597.28 21 14.43 2603 2 3
4 13 1024.00 21 14.57 1818 2 3
5 13 156.80 21 14.96 562 2 2
6 8 -0.04 170 14.97 318 2 4

Cycle 95 GMT 23/ 4/2019 1:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 28 15.21 446 2 2
2 7 2003.32 41 14.41 3129 2 2
3 13 1724.72 21 14.39 2765 2 3
4 13 1003.68 21 14.57 1786 2 2
5 13 146.44 21 14.96 548 2 2
6 8 0.12 170 14.97 319 2 5

Cycle 94 GMT 12/ 4/2019 23:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 28 14.95 464 2 2
2 7 2006.40 41 14.42 3133 2 2
3 13 1591.72 21 14.43 2592 2 3
4 13 1018.72 21 14.57 1814 2 3
5 13 158.80 21 14.96 563 2 2
6 8 0.20 170 14.97 316 2 4

Cycle 93 GMT 2/ 4/2019 23:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 14.95 460 2 2
2 7 2004.28 41 14.42 3146 2 2
3 13 1729.44 21 14.40 2771 2 4
4 13 1002.40 21 14.58 1791 2 4
5 13 279.72 21 14.90 750 2 2
6 8 0.08 170 14.97 319 2 4

Cycle 92 GMT 23/ 3/2019 23:55: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 28 14.96 453 2 2
2 7 2006.04 41 14.42 3143 2 2
3 13 1599.20 21 14.43 2606 2 3
4 13 1025.60 21 14.57 1818 2 3
5 13 166.52 21 14.96 585 2 2
6 13 13.92 21 15.01 350 2 2
7 8 1.08 170 14.96 323 2 5

Cycle 91 GMT 14/ 3/2019 0: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 28 15.09 445 2 2
2 7 2002.28 41 14.42 3123 2 2
3 13 1719.80 21 14.41 2758 2 3
4 13 995.76 21 14.59 1778 2 4
5 13 140.72 21 14.97 534 2 2
6 8 0.20 170 14.98 315 2 5

Cycle 90 GMT 3/ 3/2019 23:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 14.95 478 2 2
2 7 2002.72 41 14.42 3131 2 2
3 13 1593.32 21 14.43 2599 2 3
4 13 1024.28 21 14.57 1821 2 2
5 13 291.60 21 14.90 763 2 2
6 8 0.04 170 14.97 320 2 4

Cycle 89 GMT 21/ 2/2019 23:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.95 455 2 2
2 7 2005.76 41 14.42 3138 2 2
3 13 1600.36 21 14.43 2609 2 3
4 13 1032.00 21 14.57 1833 2 5
5 13 162.28 21 14.96 577 2 2
6 8 -0.04 170 14.97 321 2 2

Cycle 88 GMT 11/ 2/2019 23:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 28 15.22 441 2 2
2 7 2001.92 41 14.42 3126 2 2
3 13 1723.80 21 14.39 2774 2 3
4 13 994.96 21 14.58 1780 2 5
5 13 139.44 21 14.97 542 2 2
6 13 13.00 21 15.02 340 2 2
7 8 -0.12 170 14.96 319 2 6

Cycle 87 GMT 1/ 2/2019 22:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 28 15.24 433 2 2
2 7 2003.80 41 14.41 3128 2 2
3 13 1598.64 21 14.42 2605 2 3
4 13 1023.04 21 14.56 1812 2 3
5 13 162.44 21 14.96 565 2 2
6 8 -0.04 170 14.97 313 2 5

Cycle 86 GMT 22/ 1/2019 20:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 28 15.23 454 2 2
2 7 2001.92 41 14.41 3122 2 2
3 13 1728.64 21 14.39 2769 2 4
4 13 1005.88 21 14.59 1785 2 5
5 13 151.52 21 14.98 544 2 2
6 8 -0.16 170 14.99 310 2 8

Cycle 85 GMT 12/ 1/2019 19: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 14.96 451 2 2
2 7 2003.12 42 14.41 3117 2 2
3 13 1725.64 21 14.40 2764 2 4
4 13 1001.64 21 14.60 1780 2 3
5 13 142.56 21 14.99 527 2 2
6 8 0.28 170 15.00 311 2 6

Cycle 84 GMT 2/ 1/2019 19:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 28 14.96 452 2 2
2 3 1019.60 1 15.19 1820 2 2
3 7 2002.28 42 14.40 3121 2 2
4 13 1726.84 21 14.39 2770 2 3
5 13 1007.84 21 14.59 1784 2 3
6 13 272.64 21 14.92 726 2 2
7 8 -0.20 170 14.98 310 2 5

Cycle 83 GMT 23/12/2018 19:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 28 15.21 446 2 2
2 7 2003.72 41 14.40 3109 2 2
3 13 1592.84 21 14.42 2593 2 4
4 13 1025.00 21 14.57 1829 2 4
5 13 87.36 21 15.00 451 2 2
6 8 -0.08 170 14.98 311 2 4

Cycle 82 GMT 13/12/2018 17:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 28 15.21 457 2 2
2 7 2003.28 41 14.41 3116 2 2
3 13 1591.72 21 14.43 2586 2 2
4 13 1022.96 21 14.56 1807 2 3
5 13 292.24 21 14.90 747 2 2
6 8 -0.12 170 14.96 312 2 6

Cycle 81 GMT 3/12/2018 16: 3:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 28 15.21 454 2 2
2 7 2003.20 41 14.41 3129 2 3
3 13 1589.64 21 14.43 2583 2 4
4 13 1021.72 21 14.56 1812 2 4
5 13 162.72 21 14.97 560 2 2
6 8 0.00 170 14.98 310 2 6

Cycle 80 GMT 23/11/2018 14:21: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 28 14.96 456 2 2
2 7 2005.08 41 14.43 3109 2 2
3 13 1595.72 21 14.43 2598 2 3
4 13 1025.68 21 14.57 1813 2 2
5 13 153.76 21 14.98 545 2 2
6 8 0.12 170 14.99 310 2 2

Cycle 79 GMT 13/11/2018 14:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 28 15.21 452 2 2
2 7 2002.56 41 14.42 3117 2 2
3 13 1589.56 21 14.43 2587 2 3
4 13 1022.44 21 14.57 1802 2 4
5 13 156.92 21 14.97 565 2 2
6 8 0.04 170 14.98 313 2 8

Cycle 78 GMT 3/11/2018 12:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 28 15.21 445 2 2
2 7 2002.44 41 14.42 3111 2 2
3 13 1592.28 21 14.43 2589 2 4
4 13 1019.20 21 14.57 1809 2 4
5 13 158.72 21 14.97 557 2 2
6 8 0.00 170 14.98 313 2 5

Cycle 77 GMT 24/10/2018 11: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 27 14.95 468 2 2
2 7 2002.48 41 14.42 3121 2 2
3 13 1585.84 21 14.44 2594 2 3
4 13 1010.28 21 14.59 1792 2 4
5 13 141.12 21 14.99 533 2 2
6 8 0.00 170 14.99 318 2 4

Cycle 76 GMT 14/10/2018 11: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 27 15.20 465 2 2
2 7 2002.12 42 14.43 3105 2 2
3 13 1593.24 21 14.43 2599 2 3
4 13 1018.56 21 14.57 1799 2 4
5 13 282.00 21 14.91 747 2 2
6 8 -0.08 170 14.98 321 2 6

Cycle 75 GMT 4/10/2018 9:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 28 15.21 466 2 2
2 7 2002.64 41 14.42 3121 2 2
3 13 1596.96 21 14.43 2602 2 4
4 13 1026.52 21 14.58 1812 2 3
5 13 437.88 21 14.84 973 2 2
6 8 0.12 170 14.98 320 2 7

Cycle 74 GMT 24/ 9/2018 7:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 28 14.97 474 2 2
2 7 2005.96 41 14.43 3125 2 2
3 13 1595.00 21 14.44 2602 2 3
4 13 1025.16 21 14.59 1814 2 4
5 13 151.60 21 14.99 555 2 2
6 8 0.24 170 15.00 318 2 6

Cycle 73 GMT 14/ 9/2018 7:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 28 14.97 474 2 2
2 7 2003.92 41 14.44 3107 2 2
3 13 1589.96 21 14.45 2586 2 3
4 13 1005.24 21 14.60 1772 2 4
5 13 268.08 21 14.93 730 2 2
6 8 0.48 170 14.99 322 2 4
7 14 0.48 20 14.96 316 2 8

Cycle 72 GMT 4/ 9/2018 7:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 28 14.97 476 2 2
2 7 2003.44 41 14.44 3122 2 2
3 13 1603.52 21 14.45 2605 2 3
4 13 1024.64 21 14.59 1814 2 5
5 13 164.52 21 14.99 572 2 2
6 8 0.00 170 15.00 317 2 4

Cycle 71 GMT 25/ 8/2018 7:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 28 14.97 463 2 2
2 7 2005.48 41 14.44 3131 2 2
3 13 1730.64 21 14.42 2770 2 3
4 13 999.28 21 14.61 1787 2 3
5 13 275.00 21 14.94 742 2 2
6 8 0.04 170 15.00 320 2 5

Cycle 70 GMT 15/ 8/2018 7:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 27 14.98 451 2 2
2 7 2005.04 41 14.46 3118 2 2
3 13 1735.16 21 14.43 2788 2 3
4 13 1008.12 21 14.62 1789 2 4
5 13 277.64 21 14.94 731 2 2
6 8 0.00 170 15.00 317 2 6

Cycle 69 GMT 5/ 8/2018 7:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 27 15.22 449 2 2
2 7 2003.72 41 14.44 3130 2 2
3 13 1583.20 21 14.46 2574 2 3
4 13 1002.36 21 14.61 1778 2 3
5 13 135.60 21 15.00 525 2 2
6 8 0.28 170 15.00 315 2 6

Cycle 68 GMT 26/ 7/2018 6: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 15.21 461 2 2
2 7 2005.92 42 14.44 3123 2 2
3 13 1596.88 21 14.46 2591 2 3
4 13 1021.00 21 14.60 1809 2 3
5 13 151.36 21 15.00 538 2 2
6 8 0.00 170 15.01 313 2 5

Cycle 67 GMT 16/ 7/2018 4:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 27 14.98 461 2 2
2 7 2005.20 42 14.46 3120 2 2
3 13 1585.48 21 14.48 2555 2 3
4 13 1144.72 21 14.56 1964 2 5
5 13 250.76 21 14.96 697 2 2
6 8 -0.04 170 15.01 312 2 3

Cycle 66 GMT 6/ 7/2018 4:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 27 15.23 446 2 2
2 7 2006.12 42 14.45 3116 2 2
3 13 1603.04 21 14.47 2600 2 3
4 13 1031.24 21 14.61 1821 2 4
5 13 304.64 21 14.93 779 2 2
6 8 -0.08 170 15.01 316 2 7

Cycle 65 GMT 26/ 6/2018 2:33:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 27 15.01 462 2 2
2 7 2004.24 42 14.46 3123 2 2
3 13 1730.00 21 14.45 2758 2 3
4 13 1002.92 21 14.64 1783 2 5
5 13 145.24 21 15.02 539 2 2
6 8 0.00 170 15.03 318 2 3

Cycle 64 GMT 16/ 6/2018 2:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 27 15.25 455 2 2
2 7 2003.28 41 14.46 3120 2 2
3 13 1596.08 21 14.48 2597 2 3
4 13 899.32 21 14.68 1635 2 3
5 13 181.60 21 15.00 601 2 2
6 8 0.32 170 15.03 314 2 5

Cycle 63 GMT 6/ 6/2018 0:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 27 15.07 458 2 2
2 7 2005.00 42 14.46 3132 2 2
3 13 1591.36 29 14.46 2595 2 3
4 13 711.68 29 14.76 1358 2 3
5 8 0.24 170 15.03 321 2 6

Cycle 62 GMT 27/ 5/2018 0:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 27 15.27 428 2 2
2 7 2005.00 41 14.47 3121 2 2
3 13 1599.24 29 14.46 2581 2 3
4 13 847.08 29 14.69 1541 2 3
5 13 16.92 29 15.07 340 2 2
6 8 -0.20 170 15.01 315 2 6

Cycle 61 GMT 16/ 5/2018 22:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 27 15.01 453 2 2
2 7 2002.16 41 14.48 3114 2 2
3 13 1474.64 29 14.51 2415 2 3
4 13 616.24 29 14.82 1225 2 3
5 8 0.16 170 15.05 311 2 5

Cycle 60 GMT 6/ 5/2018 22:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 27 15.02 440 2 2
2 3 1021.92 1 15.21 1828 2 2
3 7 2001.48 41 14.49 3111 2 2
4 13 1592.96 29 14.48 2571 2 3
5 13 839.52 29 14.71 1543 2 4
6 13 38.96 29 15.07 382 2 2
7 8 0.00 170 15.03 317 2 6

Cycle 59 GMT 26/ 4/2018 22:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 27 15.29 428 2 2
2 7 2001.96 42 14.47 3128 2 3
3 13 1580.44 29 14.48 2566 2 2
4 13 812.76 29 14.72 1493 2 3
5 13 15.84 29 15.09 328 2 2
6 8 -0.08 170 15.03 307 2 5

Cycle 58 GMT 16/ 4/2018 21:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 27 15.30 418 2 2
2 7 2001.28 42 14.48 3115 2 2
3 13 1590.96 29 14.49 2580 2 3
4 13 832.56 29 14.73 1525 2 3
5 8 0.04 170 15.05 320 2 4

Cycle 57 GMT 6/ 4/2018 19:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 27 15.30 423 2 2
2 7 2001.72 42 14.49 3110 2 2
3 13 1584.92 29 14.50 2570 2 3
4 13 692.68 29 14.80 1326 2 3
5 8 -0.08 170 15.07 307 2 7

Cycle 56 GMT 27/ 3/2018 18: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 27 15.04 452 2 2
2 7 2004.28 41 14.49 3120 2 2
3 13 1600.84 29 14.50 2598 2 3
4 13 697.80 29 14.81 1334 2 3
5 8 0.12 170 15.08 305 2 4

Cycle 55 GMT 17/ 3/2018 18:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 27 15.31 424 2 2
2 7 2001.36 42 14.49 3120 2 2
3 13 1596.72 29 14.51 2580 2 2
4 13 704.36 29 14.81 1358 2 3
5 13 28.12 29 15.10 364 2 2
6 8 0.20 170 15.05 313 2 6

Cycle 54 GMT 7/ 3/2018 16:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 15.31 423 2 2
2 7 2005.80 41 14.49 3109 2 2
3 13 1595.28 29 14.51 2586 2 3
4 13 702.72 29 14.82 1342 2 2
5 13 18.40 29 15.11 341 2 2
6 8 0.16 170 15.06 310 2 7

Cycle 53 GMT 25/ 2/2018 15:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 27 15.32 417 2 2
2 7 2003.36 42 14.50 3111 2 2
3 13 1590.16 29 14.52 2565 2 3
4 13 690.00 29 14.84 1328 2 3
5 13 34.52 29 15.11 364 2 2
6 8 -0.08 170 15.07 308 2 5

Cycle 52 GMT 15/ 2/2018 13:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 27 15.32 428 2 2
2 7 2003.08 41 14.50 3124 2 2
3 13 1594.60 29 14.52 2574 2 3
4 13 701.40 29 14.83 1348 2 3
5 8 0.04 170 15.09 303 2 6

Cycle 51 GMT 5/ 2/2018 12:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 15.09 445 2 2
2 7 1818.92 42 14.57 2876 2 2
3 13 1549.32 29 14.56 2513 2 5
4 13 661.16 29 14.86 1288 2 3
5 8 0.20 170 15.10 309 2 4

Cycle 50 GMT 26/ 1/2018 11:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 27 15.08 452 2 2
2 7 1538.52 41 14.69 2503 2 2
3 13 1416.40 29 14.63 2351 2 4
4 13 538.20 29 14.93 1111 2 3
5 8 -0.04 170 15.11 309 2 5

Cycle 49 GMT 16/ 1/2018 11: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 27 15.10 438 2 2
2 7 1786.20 41 14.58 2833 2 3
3 13 1523.76 29 14.58 2483 2 5
4 13 617.24 29 14.89 1239 2 3
5 8 -0.04 170 15.10 317 2 3

Cycle 48 GMT 6/ 1/2018 10:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 27 15.09 466 2 2
2 7 1308.28 42 14.80 2188 2 2
3 13 1195.04 29 14.75 2025 2 5
4 13 480.28 29 14.98 1034 2 2
5 8 0.04 170 15.13 307 2 10

Cycle 47 GMT 27/12/2017 10:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 27 15.10 453 2 2
2 7 1741.56 42 14.61 2773 2 2
3 13 1484.68 29 14.60 2444 2 3
4 13 717.20 29 14.85 1372 2 3
5 8 0.24 170 15.11 315 2 5

Cycle 46 GMT 17/12/2017 10: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 27 15.10 442 2 2
2 7 1457.84 41 14.74 2393 2 4
3 13 1342.92 29 14.69 2231 2 4
4 13 463.40 29 14.99 999 2 2
5 8 -0.36 170 15.13 309 2 6

Cycle 45 GMT 7/12/2017 9:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 27 15.10 466 2 2
2 7 1757.68 41 14.62 2795 2 2
3 13 1494.96 29 14.61 2445 2 5
4 13 736.56 29 14.85 1398 2 3
5 8 -0.20 170 15.13 303 2 5

Cycle 44 GMT 27/11/2017 9:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 27 15.09 486 2 2
2 7 2003.76 41 14.53 3115 2 2
3 13 1727.44 29 14.53 2752 2 3
4 13 687.96 29 14.89 1333 2 3
5 8 -0.12 170 15.13 312 2 6

Cycle 43 GMT 17/11/2017 9:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 27 15.10 474 2 2
2 7 2001.80 41 14.53 3123 2 2
3 13 1589.64 29 14.58 2578 2 4
4 13 695.68 29 14.88 1356 2 4
5 8 -0.04 170 15.12 325 2 5

Cycle 42 GMT 7/11/2017 9:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 15.12 472 2 2
2 7 2002.76 41 14.54 3116 2 2
3 13 1594.56 29 14.58 2584 2 3
4 13 706.84 29 14.88 1374 2 3
5 8 0.32 170 15.13 324 2 4

Cycle 41 GMT 28/10/2017 9:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 27 15.11 468 2 2
2 7 2003.16 41 14.54 3112 2 2
3 13 1594.16 29 14.59 2581 2 3
4 13 840.24 29 14.82 1543 2 3
5 8 -0.16 190 15.13 319 2 13

Cycle 40 GMT 18/10/2017 9:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 15.12 471 2 2
2 7 2001.68 41 14.53 3139 2 2
3 13 1590.68 29 14.58 2586 2 2
4 13 703.16 29 14.89 1362 2 4
5 8 -0.04 190 15.13 328 2 8

Cycle 39 GMT 8/10/2017 9:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 27 15.12 481 2 2
2 7 2003.80 41 14.54 3130 2 2
3 13 1581.64 29 14.60 2569 2 4
4 13 684.20 29 14.91 1326 2 3
5 8 0.04 190 15.14 322 2 5

Cycle 38 GMT 28/ 9/2017 9: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 27 15.11 473 2 2
2 7 2004.16 41 14.54 3122 2 2
3 13 1584.32 29 14.60 2568 2 2
4 13 689.96 29 14.91 1334 2 3
5 8 -0.04 190 15.14 324 2 7

Cycle 37 GMT 18/ 9/2017 8:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 27 15.13 458 2 2
2 7 2005.12 41 14.55 3129 2 2
3 13 1464.44 29 14.64 2398 2 4
4 13 718.88 29 14.89 1373 2 3
5 13 14.84 29 15.18 338 2 2
6 8 -0.04 190 15.12 315 2 9

Cycle 36 GMT 8/ 9/2017 8:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 27 15.12 467 2 2
2 7 2003.16 41 14.55 3117 2 2
3 13 1585.56 29 14.61 2561 2 3
4 13 685.16 29 14.92 1320 2 3
5 8 0.12 190 15.14 315 2 6

Cycle 35 GMT 29/ 8/2017 8:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 27 15.13 460 2 2
2 7 2002.84 41 14.56 3126 2 2
3 13 1588.40 29 14.61 2567 2 3
4 13 831.16 29 14.85 1535 2 3
5 13 80.96 29 15.16 439 2 2
6 8 0.04 190 15.13 315 2 11

Cycle 34 GMT 19/ 8/2017 8:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 27 15.15 454 2 2
2 7 2003.40 41 14.56 3129 2 2
3 13 1591.40 29 14.61 2590 2 4
4 13 692.16 29 14.92 1329 2 3
5 8 0.40 190 15.15 316 2 5

Cycle 33 GMT 9/ 8/2017 8:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 27 15.13 455 2 2
2 7 2003.12 39 14.58 3122 2 3
3 13 1598.88 29 14.62 2590 2 2
4 13 847.28 29 14.85 1559 2 3
5 8 -0.12 190 15.16 312 2 14

Cycle 32 GMT 30/ 7/2017 8:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 27 15.15 459 2 2
2 7 2004.60 39 14.58 3134 2 2
3 13 1737.12 29 14.58 2776 2 2
4 13 815.24 29 14.87 1510 2 3
5 13 16.44 29 15.20 337 2 2
6 8 -0.08 190 15.14 316 2 10

Cycle 31 GMT 20/ 7/2017 8:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 27 15.15 474 2 2
2 7 2002.68 39 14.58 3136 2 2
3 13 1723.80 29 14.59 2757 2 3
4 13 807.60 29 14.88 1499 2 3
5 8 -0.08 190 15.17 313 2 6

Cycle 30 GMT 10/ 7/2017 8:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 27 15.15 448 2 2
2 7 2002.28 39 14.58 3127 2 2
3 13 1601.12 29 14.63 2602 2 3
4 13 715.08 29 14.93 1362 2 3
5 8 0.12 190 15.17 312 2 7

Cycle 29 GMT 30/ 6/2017 8:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 27 15.15 452 2 2
2 7 2003.48 39 14.58 3139 2 2
3 13 1600.56 29 14.63 2590 2 3
4 13 726.52 29 14.92 1385 2 3
5 13 16.76 29 15.21 337 2 2
6 8 -0.04 190 15.15 310 2 9

Cycle 28 GMT 20/ 6/2017 8:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 27 15.16 454 2 2
2 7 2003.20 40 14.59 3123 2 2
3 13 1594.92 29 14.64 2582 2 3
4 13 833.20 29 14.87 1535 2 3
5 13 30.52 29 15.21 360 2 2
6 8 -0.08 190 15.16 308 2 7

Cycle 27 GMT 10/ 6/2017 8:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 27 15.17 451 2 2
2 7 2004.08 40 14.60 3126 2 2
3 13 1598.40 29 14.64 2589 2 2
4 13 708.64 29 14.94 1356 2 3
5 8 0.08 190 15.18 310 2 6

Cycle 26 GMT 31/ 5/2017 8:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 15.17 446 2 2
2 7 2001.24 39 14.60 3116 2 2
3 13 1591.44 29 14.65 2588 2 3
4 13 837.40 29 14.87 1542 2 3
5 8 0.28 190 15.18 309 2 6

Cycle 25 GMT 21/ 5/2017 8:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 27 15.17 441 2 2
2 7 2001.96 39 14.61 3115 2 2
3 13 1598.12 29 14.65 2589 2 2
4 13 716.36 29 14.94 1361 2 2
5 8 -0.28 190 15.18 307 2 5

Cycle 24 GMT 11/ 5/2017 8:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 26 15.17 444 2 2
2 7 2003.56 40 14.61 3127 2 2
3 13 1726.60 28 14.62 2758 2 2
4 13 809.88 28 14.90 1498 2 3
5 8 -0.16 190 15.18 309 2 8

Cycle 23 GMT 1/ 5/2017 8:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 26 15.18 437 2 2
2 7 2003.56 39 14.62 3113 2 2
3 13 1597.00 28 14.66 2585 2 2
4 13 846.24 28 14.88 1548 2 4
5 13 20.32 28 15.23 336 2 2
6 8 0.04 190 15.18 307 2 8

Cycle 22 GMT 21/ 4/2017 7:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 26 15.17 444 2 2
2 7 2003.08 39 14.62 3107 2 2
3 13 1588.96 28 14.67 2565 2 2
4 13 837.96 28 14.89 1535 2 2
5 8 0.04 190 15.20 304 2 6

Cycle 21 GMT 11/ 4/2017 7:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 26 15.19 441 2 2
2 7 2004.32 39 14.62 3115 2 2
3 13 1602.12 28 14.66 2594 2 2
4 13 846.60 28 14.89 1550 2 2
5 13 37.36 28 15.22 371 2 2
6 8 -0.24 190 15.18 310 2 12

Cycle 20 GMT 1/ 4/2017 7:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 26 15.19 437 2 2
2 7 2002.52 38 14.64 3121 2 2
3 13 1602.88 28 14.67 2590 2 2
4 13 742.24 28 14.95 1402 2 2
5 8 0.00 190 15.20 308 2 5

Cycle 19 GMT 22/ 3/2017 6:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 26 15.20 430 2 2
2 7 2001.28 37 14.64 3114 2 2
3 13 1490.80 28 14.71 2431 2 2
4 13 665.44 28 14.99 1277 2 2
5 8 0.00 190 15.20 302 2 4

Cycle 18 GMT 12/ 3/2017 6:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 26 15.20 455 2 2
2 7 2003.16 37 14.66 3101 2 2
3 13 1508.60 28 14.71 2454 2 2
4 13 683.08 28 14.98 1305 2 2
5 8 -0.20 190 15.21 301 2 6

Cycle 17 GMT 2/ 3/2017 5:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 26 15.21 435 2 2
2 7 2003.68 37 14.65 3102 2 2
3 13 1485.08 28 14.72 2425 2 2
4 13 656.04 28 15.00 1268 2 2
5 8 0.16 190 15.21 301 2 5

Cycle 16 GMT 20/ 2/2017 5: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 26 15.21 423 2 2
2 7 2001.92 37 14.66 3099 2 2
3 13 1486.32 28 14.72 2412 2 2
4 13 655.88 28 15.01 1260 2 2
5 8 -0.08 190 15.22 295 2 7

Cycle 15 GMT 10/ 2/2017 4:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 26 15.20 437 2 2
2 7 2003.00 37 14.66 3107 2 2
3 13 1489.76 28 14.73 2423 2 2
4 13 659.72 28 15.01 1272 2 2
5 8 0.00 190 15.22 297 2 8

Cycle 14 GMT 31/ 1/2017 3:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 26 15.20 435 2 2
2 7 2002.68 37 14.67 3110 2 2
3 13 1486.24 28 14.73 2422 2 2
4 13 645.92 28 15.01 1246 2 2
5 8 -0.04 190 15.22 299 2 6

Cycle 13 GMT 21/ 1/2017 3:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 26 15.21 447 2 2
2 7 2002.28 37 14.68 3095 2 2
3 13 1604.16 28 14.71 2578 2 2
4 13 739.80 28 14.97 1382 2 2
5 13 19.24 28 15.26 328 2 2
6 8 -0.16 190 15.21 295 2 5

Cycle 12 GMT 11/ 1/2017 2:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 26 15.21 438 2 2
2 7 2004.04 37 14.68 3107 2 2
3 13 1487.72 28 14.73 2414 2 2
4 13 649.84 28 15.01 1258 2 2
5 8 -0.08 190 15.22 300 2 6

Cycle 11 GMT 1/ 1/2017 1:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 26 15.21 434 2 2
2 7 2000.76 38 14.69 3097 2 2
3 13 1482.84 28 14.74 2420 2 2
4 13 654.08 28 15.01 1261 2 2
5 8 0.04 190 15.22 300 2 8

Cycle 10 GMT 22/12/2016 1:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 26 15.20 459 2 2
2 7 2003.76 37 14.69 3107 2 2
3 13 1498.96 28 14.73 2439 2 2
4 13 549.64 28 15.07 1110 2 2
5 8 -0.08 190 15.23 296 2 7

Cycle 9 GMT 12/12/2016 0: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 26 15.20 454 2 2
2 7 2002.40 38 14.69 3110 2 2
3 13 1481.48 25 14.76 2421 2 2
4 13 790.36 25 14.96 1464 2 2
5 13 16.24 25 15.27 333 2 2
6 8 -0.16 190 15.21 304 2 5

Cycle 8 GMT 1/12/2016 23:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 26 15.21 453 2 2
2 7 2001.00 43 14.67 3108 2 2
3 13 1325.80 22 14.80 2198 2 2
4 13 653.20 22 15.03 1261 2 2
5 13 18.28 22 15.27 330 2 2
6 8 -0.04 240 15.21 297 2 18

Cycle 7 GMT 21/11/2016 22:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 25 15.19 457 2 2
2 7 2001.08 43 14.67 3101 2 2
3 13 1332.60 20 14.81 2211 2 2
4 13 674.80 20 15.03 1300 2 2
5 13 27.16 20 15.27 350 2 2
6 8 0.16 240 15.21 302 2 17

Cycle 6 GMT 11/11/2016 21: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 25 15.20 453 2 2
2 3 1037.60 1 15.28 1845 2 2
3 7 2001.56 49 14.65 3100 2 2
4 13 1173.56 25 14.84 1998 2 2
5 13 345.12 25 15.16 818 2 2
6 8 -0.08 240 15.21 301 2 19

Cycle 5 GMT 1/11/2016 19:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 24 15.21 464 2 2
2 7 1990.96 50 14.65 3082 2 2
3 13 1152.16 25 14.85 1971 2 2
4 13 197.08 25 15.22 594 2 2
5 8 -0.04 240 15.22 298 2 11

Cycle 4 GMT 22/10/2016 17:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 24 15.20 453 2 2
2 7 1512.56 49 14.88 2434 2 2
3 13 998.76 25 14.96 1756 2 2
4 13 36.80 25 15.30 355 2 2
5 8 -0.04 240 15.24 296 2 18

Cycle 3 GMT 21/10/2016 18: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 24 15.21 460 2 2
2 7 1508.64 50 14.88 2440 2 2
3 13 870.92 25 14.99 1575 2 2
4 13 16.60 25 15.30 330 2 2
5 8 0.08 240 15.23 300 2 18

Cycle 2 GMT 20/10/2016 18:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 24 15.20 453 2 2
2 7 1513.28 49 14.87 2441 2 2
3 13 983.44 25 14.95 1737 2 2
4 8 0.16 240 15.24 298 2 9

Cycle 1 GMT 19/10/2016 18:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 24 15.31 433 2 2
2 7 987.24 74 14.98 1708 2 2
3 8 -0.04 240 15.24 296 2 15

Cycle 0 GMT 19/10/2016 7:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 24 15.53 453 2 2
2 7 115.84 74 15.48 451 2 2
3 8 0.12 240 15.40 279 2 22