SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8474 WMO= 5902482


Cycle 338 GMT 20/12/2024 3:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 10.70 509 2 3
2 12 1115.48 3 9.27 1890 2 2
3 12 2002.32 54 8.02 3150 2 2
4 7 1998.04 24 8.10 3147 2 2
5 13 1864.88 44 8.35 2963 2 2
6 13 1430.48 44 8.83 2381 2 2
7 13 545.24 44 10.07 1117 2 3
8 8 -0.08 165 10.90 330 2 15

Cycle 337 GMT 18/12/2024 23:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 33 10.71 510 2 3
2 3 940.00 -1 11.59 0 2 3
3 12 1107.80 54 9.03 1889 2 2
4 7 1107.48 24 9.14 1911 2 2
5 13 1010.64 44 9.31 1776 2 2
6 13 595.68 44 9.94 1187 2 3
7 8 0.24 165 10.87 335 2 12

Cycle 336 GMT 9/12/2024 5:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 32 10.70 500 2 3
2 12 1117.56 54 9.09 1880 2 2
3 7 1116.64 24 9.16 1879 2 2
4 13 1009.20 44 9.36 1770 2 2
5 13 455.56 44 10.16 992 2 4
6 13 9.24 44 10.88 345 2 8
7 8 0.12 165 10.89 324 2 14

Cycle 335 GMT 29/11/2024 11:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 32 10.75 509 2 3
2 12 1108.96 54 9.16 1886 2 2
3 7 1108.00 24 9.19 1913 2 2
4 13 1000.68 44 9.40 1757 2 2
5 13 436.36 44 10.21 962 2 4
6 8 0.24 165 10.90 326 2 13

Cycle 334 GMT 19/11/2024 17:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 32 10.73 494 2 3
2 12 1112.32 3 9.39 1875 2 2
3 12 2001.00 54 8.24 3150 2 2
4 7 1996.32 24 8.25 3157 2 2
5 13 1860.48 44 8.53 2961 2 2
6 13 1137.24 44 9.39 1958 2 2
7 13 387.96 44 10.36 897 2 4
8 8 0.00 165 10.93 329 2 13

Cycle 333 GMT 18/11/2024 13:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 33 10.76 503 2 3
2 12 1120.20 54 9.17 1902 2 2
3 7 1120.08 24 9.20 1938 2 2
4 13 1019.20 44 9.41 1790 2 2
5 13 577.76 44 10.05 1167 2 3
6 8 -0.08 165 10.89 334 2 11

Cycle 332 GMT 8/11/2024 19:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 32 10.74 499 2 3
2 12 1111.52 54 9.20 1883 2 2
3 7 1110.92 24 9.24 1917 2 2
4 13 1006.16 44 9.47 1767 2 2
5 13 438.52 44 10.25 966 2 4
6 8 0.24 165 10.90 335 2 11

Cycle 331 GMT 30/10/2024 1:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 32 10.78 514 2 4
2 12 1107.88 54 9.22 1894 2 2
3 7 1107.48 24 9.29 1904 2 2
4 13 1001.52 44 9.49 1763 2 2
5 13 312.84 44 10.45 792 2 4
6 8 0.08 165 10.91 335 2 11

Cycle 330 GMT 20/10/2024 7:48:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 33 10.75 496 2 3
2 12 1101.44 3 9.53 1889 2 2
3 12 2001.16 54 8.39 3155 2 2
4 7 1996.84 24 8.57 3147 2 2
5 13 1867.76 44 8.66 2987 2 2
6 13 1124.12 44 9.52 1950 2 2
7 13 242.16 44 10.59 705 2 6
8 8 -0.04 165 10.93 344 2 15

Cycle 329 GMT 19/10/2024 4: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 33 10.77 489 2 2
2 12 1116.60 54 9.26 1899 2 2
3 7 1115.96 24 9.34 1924 2 2
4 13 1007.24 44 9.52 1771 2 2
5 13 446.60 44 10.28 980 2 4
6 13 26.76 44 10.88 376 2 5
7 8 0.20 165 10.91 334 2 22

Cycle 328 GMT 9/10/2024 10: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 32 10.80 500 2 3
2 3 1020.72 1 9.81 1780 2 2
3 12 1124.48 54 9.27 1915 2 2
4 7 1123.88 24 9.34 1933 2 2
5 13 1017.28 44 9.55 1789 2 2
6 13 316.36 44 10.48 786 2 5
7 8 -0.24 165 10.93 326 2 17

Cycle 327 GMT 29/ 9/2024 15:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 31 10.81 500 2 3
2 12 1114.28 54 9.33 1882 2 2
3 7 1113.60 24 9.37 1924 2 2
4 13 1009.72 44 9.56 1789 2 2
5 13 434.48 44 10.33 969 2 4
6 8 0.20 165 10.92 339 2 11

Cycle 326 GMT 19/ 9/2024 21:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 32 10.74 523 2 3
2 3 1014.08 1 9.97 1783 2 2
3 12 1120.72 3 9.66 1899 2 2
4 12 2005.24 54 8.51 3175 2 2
5 7 2000.76 24 8.56 3150 2 2
6 13 1868.44 44 8.81 2987 2 2
7 13 1009.92 44 9.72 1788 2 2
8 13 243.96 44 10.62 700 2 6
9 8 -0.20 165 10.95 338 2 15

Cycle 325 GMT 18/ 9/2024 17:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 32 10.77 509 2 3
2 3 1020.12 1 9.88 1797 2 2
3 12 1129.56 54 9.31 1924 2 2
4 7 1128.72 24 9.38 1936 2 2
5 13 1020.92 44 9.58 1796 2 2
6 13 431.12 44 10.34 960 2 4
7 8 0.60 165 10.92 340 2 15

Cycle 324 GMT 8/ 9/2024 23:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 31 10.80 486 2 3
2 12 1117.52 54 9.34 1909 2 2
3 7 1116.40 24 9.43 1927 2 2
4 13 999.04 44 9.63 1770 2 2
5 13 551.44 44 10.20 1140 2 4
6 8 0.20 165 10.93 339 2 10

Cycle 323 GMT 30/ 8/2024 5:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 32 10.82 499 2 3
2 12 1112.92 54 9.41 1892 2 2
3 7 1111.88 24 9.47 1923 2 2
4 13 1003.52 44 9.64 1778 2 2
5 13 313.48 44 10.51 791 2 5
6 8 -0.36 165 10.93 334 2 9

Cycle 322 GMT 20/ 8/2024 11:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 32 10.77 495 2 3
2 3 971.12 -1 11.57 0 2 3
3 3 1031.44 1 9.79 1782 2 2
4 12 1118.80 3 9.53 1893 2 2
5 12 2001.00 54 8.51 3165 2 2
6 7 1996.28 24 8.62 3165 2 2
7 13 1859.32 44 8.82 2981 2 2
8 13 1123.00 44 9.62 1950 2 2
9 13 211.80 44 10.67 656 2 6
10 8 0.16 165 10.95 337 2 12

Cycle 321 GMT 19/ 8/2024 8:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 33 10.78 494 2 3
2 12 1108.92 54 9.37 1887 2 2
3 7 1107.72 24 9.45 1914 2 2
4 13 993.88 44 9.63 1757 2 2
5 13 415.56 44 10.37 935 2 4
6 8 0.08 165 10.93 329 2 10

Cycle 320 GMT 9/ 8/2024 14:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 33 10.78 497 2 3
2 3 958.04 -1 11.58 0 2 3
3 12 1114.80 54 9.36 1895 2 2
4 7 1113.80 24 9.45 1930 2 2
5 13 1003.96 44 9.64 1769 2 2
6 13 418.96 44 10.37 940 2 4
7 8 -0.08 165 10.94 327 2 13

Cycle 319 GMT 30/ 7/2024 20:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 32 10.82 492 2 3
2 3 1015.28 1 9.93 1782 2 2
3 12 1111.80 54 9.40 1907 2 2
4 7 1110.48 24 9.50 1906 2 2
5 13 999.20 44 9.65 1767 2 2
6 13 317.04 44 10.51 796 2 5
7 8 0.36 165 10.94 328 2 11

Cycle 318 GMT 21/ 7/2024 2:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 30 10.71 514 2 3
2 3 1046.20 2 9.72 1801 2 2
3 3 1015.64 1 9.84 1777 2 2
4 12 1122.92 3 9.53 1896 2 2
5 12 2002.04 54 8.39 3147 2 2
6 7 1997.60 24 8.48 3146 2 2
7 13 1861.36 44 8.69 2973 2 2
8 13 1124.32 44 9.54 1949 2 2
9 13 243.00 44 10.62 693 2 5
10 8 0.00 165 10.95 325 2 10

Cycle 317 GMT 19/ 7/2024 22:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 29 10.99 489 2 3
2 10 1000.56 4 10.22 1759 2 2
3 12 1110.32 54 9.56 1907 2 2
4 7 1108.96 24 9.60 1929 2 2
5 13 989.64 44 9.67 1753 2 2
6 13 294.44 44 10.50 764 2 5
7 8 -0.40 165 10.91 328 2 12

Cycle 316 GMT 10/ 7/2024 4:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 32 11.24 492 2 3
2 12 1108.64 54 9.10 1881 2 2
3 7 1108.56 24 9.55 1915 2 2
4 13 1009.68 44 9.55 1780 2 2
5 13 571.40 44 10.26 1161 2 3
6 8 0.16 165 11.11 326 2 13

Cycle 315 GMT 30/ 6/2024 10:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 11.46 498 2 3
2 10 1015.40 4 10.90 1812 2 2
3 12 1123.88 54 9.60 1926 2 2
4 7 1122.84 24 9.81 1940 2 2
5 13 1011.12 44 9.82 1785 2 2
6 13 437.68 44 10.70 967 2 4
7 13 44.16 44 11.30 393 2 7
8 8 -0.24 165 11.32 324 2 15

Cycle 314 GMT 20/ 6/2024 16:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 27 12.03 499 2 3
2 10 1023.56 4 11.39 1838 2 2
3 12 1105.40 3 11.11 1891 2 2
4 12 2000.64 54 9.35 3179 2 2
5 7 1995.48 24 9.30 3171 2 2
6 13 1581.44 44 9.63 2591 2 2
7 13 837.76 44 10.54 1546 2 3
8 8 0.12 165 11.59 325 2 16

Cycle 313 GMT 19/ 6/2024 13: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 27 12.44 495 2 3
2 3 1061.28 2 12.00 1883 2 2
3 3 1017.92 1 11.66 1818 2 2
4 12 1124.44 54 9.89 1908 2 2
5 7 1123.28 24 10.57 1961 2 2
6 13 1009.60 44 10.29 1791 2 2
7 13 148.56 44 12.03 556 2 7
8 8 0.16 165 12.08 329 2 16

Cycle 312 GMT 9/ 6/2024 18:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 27 12.85 508 2 4
2 3 1020.88 1 12.23 1805 2 2
3 12 1131.20 54 9.04 1912 2 2
4 7 1130.96 24 10.33 1961 2 2
5 13 1027.52 44 10.22 1808 2 2
6 13 329.48 44 12.01 814 2 7
7 8 -0.08 165 12.43 331 2 19

Cycle 311 GMT 31/ 5/2024 0:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 26 13.20 500 2 5
2 3 1022.76 1 12.28 1831 2 2
3 12 1126.80 54 9.51 1900 2 2
4 7 1125.80 24 10.59 1952 2 2
5 13 1007.08 44 10.69 1791 2 2
6 13 284.72 44 12.49 758 2 7
7 8 0.32 165 12.78 338 2 13

Cycle 310 GMT 21/ 5/2024 6:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 27 13.57 516 2 4
2 3 1021.44 1 11.89 1829 2 2
3 12 1114.88 3 11.52 1930 2 2
4 12 1998.20 54 10.01 3190 2 2
5 7 1992.60 24 10.38 3183 2 2
6 13 1424.28 44 11.17 2393 2 2
7 13 377.80 44 12.68 884 2 7
8 8 0.08 165 13.06 342 2 10

Cycle 309 GMT 20/ 5/2024 3:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 27 13.73 514 2 5
2 12 1104.28 54 8.67 1858 2 2
3 7 1105.60 24 10.46 1932 2 2
4 13 1010.96 44 10.66 1794 2 2
5 13 443.72 44 12.64 976 2 6
6 8 0.00 165 13.36 343 2 17

Cycle 308 GMT 10/ 5/2024 9:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 26 13.90 502 2 5
2 3 1020.72 1 11.89 1803 2 2
3 12 1129.88 54 9.14 1901 2 2
4 7 1129.56 24 10.59 1969 2 2
5 13 1022.16 44 10.98 1816 2 2
6 13 422.28 44 12.98 954 2 7
7 8 0.20 165 13.52 342 2 20

Cycle 307 GMT 30/ 4/2024 15:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 27 13.94 509 2 5
2 3 963.76 -1 14.99 0 2 5
3 12 1121.96 54 9.71 1912 2 2
4 7 1120.92 24 10.92 1961 2 2
5 13 1009.36 44 11.49 1788 2 3
6 13 133.20 44 13.70 539 2 10
7 8 -0.08 165 13.66 336 2 15

Cycle 306 GMT 20/ 4/2024 21:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 26 13.95 508 2 5
2 3 1018.12 1 11.69 1809 2 2
3 12 1117.48 3 11.52 1923 2 2
4 12 2003.32 54 10.30 3203 2 2
5 7 1998.04 25 10.59 3205 2 2
6 13 1418.24 44 12.04 2394 2 3
7 13 328.92 44 13.50 823 2 10
8 8 0.24 165 13.75 348 2 15

Cycle 305 GMT 19/ 4/2024 18: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 27 13.96 521 2 5
2 12 1109.00 54 9.02 1874 2 2
3 7 1109.76 24 10.74 1934 2 2
4 13 1007.32 44 11.48 1797 2 3
5 13 270.00 44 13.49 744 2 9
6 8 0.00 165 13.77 348 2 15

Cycle 304 GMT 10/ 4/2024 0:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 26 14.02 518 2 4
2 3 1024.76 1 12.16 1821 2 2
3 12 1134.84 54 9.18 1884 2 2
4 7 1135.20 24 10.70 1969 2 2
5 13 1032.12 44 11.65 1834 2 3
6 13 138.96 44 13.76 548 2 10
7 8 0.08 165 13.82 341 2 20

Cycle 303 GMT 31/ 3/2024 6: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 26 14.02 513 2 5
2 3 1013.56 1 12.05 1849 2 2
3 12 1151.12 54 9.73 1960 2 2
4 7 1149.96 24 11.03 1998 2 2
5 13 1020.32 44 12.08 1821 2 3
6 13 115.28 44 13.85 516 2 11
7 8 0.12 165 13.87 338 2 18

Cycle 302 GMT 21/ 3/2024 12: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 26 14.02 516 2 5
2 12 1101.72 3 11.70 1926 2 2
3 12 1998.36 54 10.42 3199 2 2
4 7 1992.56 24 10.71 3203 2 2
5 13 1266.28 44 12.38 2146 2 3
6 13 187.20 44 13.80 622 2 11
7 8 0.00 165 13.88 346 2 13
8 14 0.00 25 13.69 349 2 16

Cycle 301 GMT 20/ 3/2024 8:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 26 14.07 522 2 5
2 3 1023.24 1 12.03 1814 2 2
3 12 1141.64 54 8.89 1891 2 2
4 7 1142.64 24 10.78 1981 2 2
5 13 1045.80 44 11.75 1858 2 3
6 13 295.56 44 13.57 779 2 10
7 8 -0.04 165 13.90 353 2 15

Cycle 300 GMT 10/ 3/2024 14:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 26 14.07 513 2 5
2 12 1112.52 54 9.15 1876 2 2
3 7 1112.32 24 10.91 1951 2 2
4 13 999.24 44 12.01 1776 2 3
5 13 126.96 44 13.87 542 2 11
6 8 0.32 165 13.92 355 2 16

Cycle 299 GMT 29/ 2/2024 20:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 26 14.10 526 2 5
2 12 1110.48 54 9.86 1898 2 2
3 7 1109.64 24 11.13 1945 2 2
4 13 990.32 44 12.27 1790 2 4
5 13 87.36 44 13.95 486 2 11
6 8 0.08 165 13.94 355 2 12

Cycle 298 GMT 20/ 2/2024 2:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 27 14.09 517 2 5
2 12 1102.68 3 11.61 1921 2 2
3 12 1997.48 54 10.41 3187 2 2
4 7 1991.64 24 10.78 3193 2 2
5 13 1276.64 44 12.47 2165 2 3
6 13 204.32 44 13.84 651 2 11
7 8 0.08 165 13.96 347 2 10

Cycle 297 GMT 18/ 2/2024 22:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 27 14.07 506 2 5
2 12 1107.80 54 9.00 1855 2 2
3 7 1108.56 24 10.96 1935 2 2
4 13 1006.48 44 12.02 1803 2 3
5 13 250.52 44 13.71 709 2 10
6 8 0.16 165 13.98 346 2 16

Cycle 296 GMT 9/ 2/2024 4:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 26 14.09 526 2 5
2 12 1122.72 54 9.26 1883 2 2
3 7 1122.64 24 10.95 1973 2 2
4 13 1012.92 44 12.13 1813 2 3
5 13 127.04 44 13.91 540 2 11
6 8 0.00 165 13.99 347 2 14

Cycle 295 GMT 30/ 1/2024 10:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 26 14.09 517 2 5
2 12 1130.56 54 9.82 1938 2 2
3 7 1129.44 24 11.20 1979 2 2
4 13 1005.08 44 12.42 1796 2 4
5 13 46.24 44 14.04 423 2 11
6 8 0.24 165 14.01 350 2 18

Cycle 294 GMT 20/ 1/2024 16:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 27 14.07 521 2 5
2 12 1107.24 3 11.69 1944 2 2
3 12 1997.72 54 10.48 3199 2 2
4 7 1991.76 24 10.83 3184 2 2
5 13 1286.20 44 12.54 2168 2 4
6 13 196.28 44 13.86 632 2 11
7 8 0.20 165 13.99 350 2 16

Cycle 293 GMT 19/ 1/2024 13: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 25 14.08 514 2 5
2 3 1046.60 2 12.46 1877 2 2
3 12 1129.00 54 9.02 1877 2 2
4 7 1130.04 24 10.99 1989 2 2
5 13 1028.56 44 12.15 1846 2 3
6 13 140.48 44 13.89 561 2 11
7 8 -0.28 165 13.99 353 2 14

Cycle 292 GMT 9/ 1/2024 18:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 26 14.06 519 2 5
2 12 1125.40 54 9.28 1889 2 2
3 7 1125.72 24 11.06 1972 2 2
4 13 1023.56 44 12.26 1834 2 3
5 13 126.64 44 13.91 539 2 11
6 8 0.24 165 14.01 348 2 15

Cycle 291 GMT 31/12/2023 0:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 26 14.06 510 2 5
2 12 1108.04 54 9.87 1893 2 2
3 7 1106.56 24 11.24 1946 2 2
4 13 992.08 44 12.52 1791 2 4
5 13 44.56 44 14.02 423 2 11
6 8 0.00 165 14.00 354 2 20

Cycle 290 GMT 21/12/2023 7: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 27 14.02 528 2 5
2 12 1105.84 3 11.74 1934 2 2
3 12 1998.32 54 10.52 3197 2 2
4 7 1992.28 24 10.84 3185 2 2
5 13 1260.40 44 12.61 2132 2 3
6 13 176.76 44 13.88 609 2 11
7 8 0.04 165 13.98 354 2 19

Cycle 289 GMT 20/12/2023 3:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 14.04 523 2 5
2 3 967.84 -1 14.96 0 2 5
3 12 1123.60 54 8.76 1873 2 2
4 7 1124.72 24 11.10 1969 2 2
5 13 1026.44 44 12.24 1847 2 3
6 13 272.36 44 13.72 759 2 11
7 8 0.08 165 13.97 357 2 17

Cycle 288 GMT 10/12/2023 9:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 27 14.02 520 2 5
2 12 1114.36 54 9.17 1865 2 2
3 7 1114.64 24 11.12 1956 2 2
4 13 1005.52 44 12.38 1804 2 4
5 13 120.04 44 13.93 534 2 12
6 8 -0.24 165 13.98 354 2 13
7 14 -0.24 25 14.00 351 2 18

Cycle 287 GMT 30/11/2023 15:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 26 14.05 516 2 6
2 3 1021.44 1 12.58 1824 2 2
3 12 1135.00 54 9.78 1920 2 2
4 7 1133.84 24 11.28 1975 2 2
5 13 1011.72 44 12.60 1789 2 4
6 13 96.00 44 13.98 491 2 11
7 8 0.24 165 14.00 348 2 16

Cycle 286 GMT 20/11/2023 21:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 26 14.03 511 2 6
2 3 1020.04 1 12.20 1824 2 2
3 12 1115.84 3 11.71 1954 2 2
4 12 1998.40 54 10.53 3217 2 2
5 7 1992.44 24 10.90 3211 2 2
6 13 1390.08 44 12.50 2328 2 3
7 13 268.32 44 13.80 742 2 12
8 8 0.12 165 13.97 356 2 19

Cycle 285 GMT 19/11/2023 18:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 27 13.99 546 2 5
2 12 1114.04 54 8.68 1845 2 2
3 7 1115.40 24 11.13 1962 2 2
4 13 1019.52 44 12.33 1801 2 3
5 13 412.36 44 13.55 955 2 10
6 8 0.00 165 13.97 360 2 18

Cycle 284 GMT 10/11/2023 0:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 26 14.02 523 2 6
2 12 1123.80 54 9.10 1887 2 2
3 7 1124.08 24 11.17 1975 2 2
4 13 1015.48 44 12.44 1801 2 3
5 13 130.00 44 13.92 546 2 11
6 8 0.00 165 13.98 357 2 16

Cycle 283 GMT 31/10/2023 6:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 14.02 515 2 5
2 3 962.60 -1 14.91 0 2 5
3 12 1130.72 54 9.71 1909 2 2
4 7 1129.40 24 11.26 1990 2 2
5 13 1008.32 44 12.62 1830 2 4
6 13 24.76 44 14.07 402 2 10
7 8 0.40 165 13.98 362 2 14

Cycle 282 GMT 21/10/2023 12:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 26 14.00 533 2 5
2 12 1112.04 3 11.63 1946 2 2
3 12 1998.04 54 10.47 3201 2 2
4 7 1992.04 24 10.84 3219 2 2
5 13 1543.64 44 12.26 2600 2 3
6 13 262.36 44 13.80 753 2 11
7 8 0.00 165 13.99 358 2 14

Cycle 281 GMT 20/10/2023 8:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 27 14.00 518 2 5
2 12 1099.08 54 8.63 1837 2 2
3 7 1100.36 24 11.17 1941 2 2
4 13 998.20 44 12.38 1810 2 4
5 13 123.92 44 13.93 536 2 11
6 8 -0.44 165 13.99 351 2 15

Cycle 280 GMT 10/10/2023 14:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 26 14.02 515 2 5
2 3 1054.20 2 12.67 1888 2 3
3 3 1014.32 1 11.98 1847 2 2
4 12 1122.40 54 9.18 1876 2 2
5 7 1122.44 24 11.24 1965 2 2
6 13 1013.16 44 12.48 1818 2 4
7 13 59.92 44 14.01 450 2 11
8 8 0.16 165 13.98 359 2 16

Cycle 279 GMT 30/ 9/2023 20:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 27 14.00 522 2 5
2 3 945.20 -1 14.93 0 2 5
3 12 1133.56 54 9.65 1924 2 2
4 7 1133.44 24 11.34 1987 2 2
5 13 1016.72 44 12.61 1833 2 4
6 13 107.00 44 13.97 518 2 12
7 8 -0.28 165 13.99 353 2 19

Cycle 278 GMT 21/ 9/2023 2:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 27 14.01 516 2 5
2 12 1083.96 3 11.72 1891 2 2
3 12 1997.60 54 10.37 3195 2 2
4 7 1991.88 24 10.84 3214 2 2
5 13 1148.20 44 12.80 1963 2 4
6 13 116.36 44 13.98 531 2 12
7 8 0.04 165 14.01 351 2 21

Cycle 277 GMT 19/ 9/2023 22:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 27 14.00 519 2 5
2 12 1111.60 54 8.41 1826 2 2
3 7 1113.24 24 11.21 1948 2 2
4 13 1013.20 44 12.45 1796 2 3
5 13 267.80 44 13.75 749 2 11
6 8 0.72 165 13.96 362 2 16

Cycle 276 GMT 10/ 9/2023 4:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 25 14.02 507 2 5
2 3 1049.60 2 12.61 1860 2 3
3 3 1015.40 1 11.88 1836 2 2
4 12 1130.92 54 9.05 1887 2 2
5 7 1131.16 24 11.27 1985 2 2
6 13 1026.60 44 12.48 1844 2 4
7 13 58.24 44 14.01 446 2 10
8 8 -0.28 165 13.99 357 2 19

Cycle 275 GMT 31/ 8/2023 10:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 28 14.00 514 2 5
2 3 924.56 -1 14.93 0 2 5
3 3 963.48 -1 14.93 0 2 5
4 12 1144.80 54 9.53 1926 2 2
5 7 1144.36 24 11.36 2005 2 2
6 13 1029.92 44 12.62 1854 2 4
7 8 0.04 165 14.00 357 2 16

Cycle 274 GMT 21/ 8/2023 16:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 27 13.96 529 2 5
2 12 1119.56 3 11.67 1953 2 2
3 12 1997.80 54 10.44 3193 2 2
4 7 1991.88 24 10.84 3205 2 2
5 13 1412.76 44 12.45 2409 2 3
6 13 178.32 44 13.90 623 2 11
7 8 0.12 165 13.98 361 2 21

Cycle 273 GMT 20/ 8/2023 12:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 26 13.98 521 2 5
2 3 1013.60 1 12.18 1825 2 2
3 12 1096.80 54 8.34 1802 2 2
4 7 1098.60 24 11.22 1929 2 2
5 13 1012.80 44 12.47 1809 2 3
6 13 141.52 44 13.92 555 2 11
7 8 0.12 165 13.99 352 2 19

Cycle 272 GMT 10/ 8/2023 18:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 27 13.98 520 2 5
2 3 1022.56 1 12.31 1821 2 2
3 12 1151.44 54 8.88 1897 2 2
4 7 1152.12 24 11.28 2012 2 2
5 13 1047.40 44 12.51 1869 2 4
6 13 153.96 44 13.91 582 2 10
7 8 -0.04 165 14.01 351 2 15

Cycle 271 GMT 1/ 8/2023 0:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 28 13.97 518 2 5
2 12 1103.16 54 9.64 1865 2 2
3 7 1102.44 24 11.41 1946 2 2
4 13 983.72 44 12.70 1781 2 4
5 8 0.20 165 14.01 352 2 13

Cycle 270 GMT 22/ 7/2023 6:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 28 13.95 518 2 5
2 3 968.68 -1 14.97 0 2 5
3 3 1014.28 1 11.73 1808 2 2
4 12 1117.56 3 11.67 1950 2 2
5 12 2001.16 54 10.41 3198 2 2
6 7 1995.28 24 10.85 3199 2 2
7 13 1407.44 44 12.47 2389 2 3
8 13 432.40 44 13.61 980 2 10
9 8 0.04 165 14.00 357 2 17

Cycle 269 GMT 21/ 7/2023 3:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 26 13.95 528 2 5
2 12 1134.20 54 8.35 1853 2 2
3 7 1136.36 24 11.25 1991 2 2
4 13 1048.72 44 12.44 1874 2 3
5 13 312.04 44 13.70 807 2 10
6 8 0.28 165 13.98 359 2 16

Cycle 268 GMT 11/ 7/2023 9: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 13.97 528 2 5
2 12 1072.76 54 9.14 1821 2 2
3 7 1073.88 24 11.39 1896 2 2
4 13 980.40 44 12.56 1782 2 4
5 13 97.92 44 13.94 511 2 11
6 8 0.00 165 13.96 363 2 19

Cycle 267 GMT 1/ 7/2023 15:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 13.94 527 2 5
2 3 1035.64 1 12.75 1856 2 2
3 12 1140.88 54 9.56 1907 2 2
4 7 1140.08 24 11.43 1995 2 2
5 13 1020.92 44 12.69 1834 2 4
6 13 57.24 44 14.01 444 2 11
7 8 0.52 165 13.99 354 2 12

Cycle 266 GMT 21/ 6/2023 21: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 27 13.94 531 2 5
2 12 1132.40 3 11.66 1981 2 2
3 12 1999.96 54 10.36 3198 2 2
4 7 1994.32 24 10.86 3200 2 2
5 13 1278.92 44 12.64 2163 2 3
6 13 318.64 44 13.73 817 2 11
7 8 -0.12 165 13.99 355 2 17

Cycle 265 GMT 20/ 6/2023 17:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 28 13.94 514 2 5
2 3 952.16 -1 14.97 0 2 5
3 12 1108.72 54 8.38 1803 2 2
4 7 1110.88 24 11.29 1951 2 2
5 13 1025.20 44 12.45 1846 2 4
6 13 297.64 44 13.70 794 2 10
7 8 -0.08 165 13.97 358 2 18

Cycle 264 GMT 10/ 6/2023 23:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 26 13.93 524 2 5
2 3 1015.28 1 12.23 1829 2 2
3 12 1134.20 54 8.83 1875 2 2
4 7 1135.92 24 11.37 1993 2 2
5 13 1041.52 44 12.54 1865 2 4
6 13 135.72 44 13.91 554 2 11
7 8 0.20 165 13.98 352 2 12

Cycle 263 GMT 1/ 6/2023 5:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 27 13.96 514 2 5
2 12 1098.24 54 9.70 1856 2 2
3 7 1097.56 24 11.49 1933 2 2
4 13 989.56 44 12.71 1794 2 4
5 13 43.96 44 14.03 419 2 10
6 8 -0.04 165 13.98 354 2 16

Cycle 262 GMT 22/ 5/2023 11:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 28 13.94 522 2 5
2 12 1118.92 3 11.62 1926 2 2
3 12 1998.52 54 10.31 3193 2 2
4 7 1992.88 24 10.87 3196 2 2
5 13 1283.84 44 12.64 2173 2 3
6 13 350.80 44 13.69 860 2 11
7 8 -0.08 165 13.99 355 2 18

Cycle 261 GMT 21/ 5/2023 8:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 27 13.93 528 2 5
2 3 1016.04 1 12.26 1831 2 2
3 12 1119.56 54 8.24 1829 2 2
4 7 1121.36 24 11.29 1974 2 2
5 13 1026.28 44 12.52 1838 2 4
6 13 423.80 44 13.57 960 2 10
7 8 0.36 165 13.98 353 2 20

Cycle 260 GMT 11/ 5/2023 14:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 27 13.98 522 2 5
2 12 1119.32 54 8.99 1862 2 2
3 7 1120.32 24 11.37 1967 2 2
4 13 1019.84 44 12.54 1833 2 4
5 13 123.88 44 13.90 542 2 11
6 8 0.20 165 13.96 356 2 18

Cycle 259 GMT 1/ 5/2023 20:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 27 13.93 515 2 5
2 12 1116.12 54 9.71 1896 2 2
3 7 1115.40 24 11.50 1961 2 2
4 13 997.04 44 12.70 1806 2 4
5 13 23.36 44 14.05 390 2 10
6 8 0.36 165 13.97 353 2 17

Cycle 258 GMT 22/ 4/2023 2:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 28 13.93 534 2 5
2 12 1114.04 3 11.68 1945 2 2
3 12 2001.48 54 10.28 3199 2 2
4 7 1996.00 24 10.89 3214 2 2
5 13 1398.92 44 12.52 2331 2 3
6 13 312.84 44 13.71 822 2 11
7 8 -0.12 165 13.98 357 2 17

Cycle 257 GMT 20/ 4/2023 23: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 13.88 526 2 5
2 12 1125.40 54 8.29 1841 2 2
3 7 1127.56 24 11.33 1979 2 2
4 13 1036.72 44 12.51 1861 2 4
5 13 304.56 44 13.69 801 2 10
6 8 -0.04 165 13.95 358 2 19

Cycle 256 GMT 11/ 4/2023 5: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 25 13.94 522 2 5
2 3 1066.48 2 12.77 1918 2 3
3 12 1121.76 54 8.96 1871 2 2
4 7 1122.48 24 11.39 1979 2 2
5 13 1020.36 44 12.60 1838 2 4
6 13 133.68 44 13.90 551 2 11
7 8 0.04 165 13.95 357 2 16

Cycle 255 GMT 1/ 4/2023 11: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 26 13.93 546 2 4
2 3 971.12 -1 15.02 0 2 4
3 12 1127.76 54 9.68 1906 2 2
4 7 1128.08 24 11.52 1976 2 2
5 13 1026.56 44 12.73 1838 2 4
6 13 56.28 44 13.99 440 2 9
7 8 -0.12 165 13.97 355 2 14

Cycle 254 GMT 22/ 3/2023 16:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 27 13.92 521 2 5
2 3 1027.80 1 12.39 1822 2 2
3 12 1122.16 3 11.68 1937 2 2
4 12 2002.88 54 10.33 3205 2 2
5 7 1997.32 24 10.90 3222 2 2
6 13 1287.04 44 12.64 2186 2 3
7 13 343.08 44 13.69 851 2 11
8 13 19.56 44 14.04 387 2 10
9 8 -0.24 165 14.00 353 2 22

Cycle 253 GMT 21/ 3/2023 13:20: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 13.90 527 2 5
2 3 967.44 -1 15.03 0 2 5
3 12 1131.76 54 8.11 1843 2 2
4 7 1134.08 24 11.30 1988 2 2
5 13 1053.12 44 12.50 1877 2 3
6 13 453.64 44 13.52 1004 2 9
7 8 -0.20 165 13.97 352 2 18

Cycle 252 GMT 11/ 3/2023 19:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 28 13.91 527 2 5
2 3 947.60 -1 15.03 0 2 5
3 12 1118.96 54 8.80 1833 2 2
4 7 1120.44 24 11.39 1971 2 2
5 13 1026.72 44 12.57 1844 2 4
6 13 133.84 44 13.88 561 2 11
7 8 0.08 165 13.96 354 2 20

Cycle 251 GMT 2/ 3/2023 1:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 27 13.93 518 2 5
2 3 1033.88 1 12.62 1840 2 2
3 12 1114.20 54 9.56 1872 2 2
4 7 1114.40 24 11.55 1970 2 2
5 13 1006.12 44 12.73 1819 2 5
6 13 51.84 44 13.99 431 2 11
7 8 0.00 165 13.98 353 2 21

Cycle 250 GMT 20/ 2/2023 7:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 28 13.92 503 2 4
2 3 954.64 -1 15.05 0 2 4
3 12 1119.08 3 11.67 1942 2 2
4 12 1997.44 54 10.27 3195 2 2
5 7 1991.52 24 10.91 3193 2 2
6 13 1544.12 44 12.31 2584 2 3
7 13 410.00 44 13.60 964 2 10
8 8 0.16 165 14.02 351 2 11

Cycle 249 GMT 19/ 2/2023 4:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 13.90 516 2 3
2 12 1109.36 54 8.26 1809 2 2
3 7 1112.00 24 11.37 1961 2 2
4 13 1028.96 44 12.53 1840 2 3
5 13 291.24 44 13.70 784 2 10
6 8 -0.08 165 13.99 347 2 14

Cycle 248 GMT 9/ 2/2023 10:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 28 13.93 522 2 4
2 3 972.76 -1 15.04 0 2 4
3 12 1133.64 54 8.77 1860 2 2
4 7 1135.40 24 11.44 1993 2 2
5 13 1045.84 44 12.59 1875 2 4
6 13 143.68 44 13.89 564 2 12
7 8 0.24 165 13.99 346 2 14

Cycle 247 GMT 30/ 1/2023 16:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 27 13.92 519 2 5
2 3 1025.72 1 12.53 1828 2 2
3 12 1122.72 54 9.60 1889 2 2
4 7 1122.80 24 11.58 1975 2 2
5 13 1011.40 44 12.77 1828 2 4
6 13 52.20 44 14.01 428 2 11
7 8 0.24 165 14.02 346 2 17

Cycle 246 GMT 20/ 1/2023 22:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 28 13.89 518 2 4
2 12 1120.32 3 11.75 1934 2 2
3 12 1999.44 54 10.35 3188 2 2
4 7 1993.68 24 10.96 3178 2 2
5 13 1394.28 44 12.52 2347 2 3
6 13 417.72 44 13.59 970 2 11
7 8 -0.16 165 14.03 348 2 20

Cycle 245 GMT 19/ 1/2023 19:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 13.92 508 2 5
2 3 969.08 -1 15.06 0 2 5
3 3 1019.00 1 12.09 1825 2 2
4 12 1138.00 54 8.16 1847 2 2
5 7 1140.28 24 11.40 1987 2 2
6 13 1053.04 44 12.58 1874 2 4
7 13 187.44 44 13.83 622 2 11
8 8 0.00 165 14.00 340 2 16

Cycle 244 GMT 10/ 1/2023 1:23:29

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 27 13.91 514 2 5
2 3 1013.80 1 12.22 1816 2 2
3 12 1139.76 54 8.83 1881 2 2
4 7 1141.08 24 11.41 2001 2 2
5 13 1043.44 44 12.61 1868 2 4
6 13 144.48 44 13.86 567 2 11
7 8 0.20 165 13.98 348 2 24

Cycle 243 GMT 31/12/2022 7:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 28 13.93 516 2 5
2 3 971.40 -1 15.07 0 2 5
3 12 1136.08 54 9.64 1912 2 2
4 7 1135.20 24 11.53 1990 2 2
5 13 1017.08 44 12.76 1828 2 4
6 13 102.36 44 13.91 508 2 12
7 8 0.32 165 13.97 354 2 29

Cycle 242 GMT 21/12/2022 13:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 28 13.89 528 2 5
2 12 1099.60 3 11.67 1913 2 2
3 12 1999.84 54 10.24 3201 2 2
4 7 1994.04 24 10.92 3196 2 2
5 13 1417.76 44 12.48 2390 2 3
6 13 292.96 44 13.72 771 2 11
7 8 -0.32 165 13.99 347 2 17

Cycle 241 GMT 20/12/2022 9:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 25 13.90 527 2 5
2 10 1019.32 6 13.05 1840 2 3
3 12 1086.16 54 8.13 1779 2 2
4 7 1088.64 24 11.41 1925 2 2
5 13 999.64 44 12.62 1800 2 4
6 13 409.80 44 13.54 944 2 10
7 8 0.20 165 13.96 346 2 20

Cycle 240 GMT 10/12/2022 16:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 27 13.92 515 2 5
2 12 1134.04 54 8.58 1860 2 2
3 7 1135.04 24 11.41 1996 2 2
4 13 1035.28 44 12.62 1852 2 4
5 13 168.56 44 13.82 595 2 11
6 8 0.00 165 13.96 346 2 19

Cycle 239 GMT 30/11/2022 22: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 26 13.91 532 2 5
2 10 1000.20 6 13.19 1809 2 3
3 3 896.12 -2 15.10 0 2 3
4 3 967.12 -1 15.09 0 2 3
5 12 1140.80 54 9.49 1894 2 2
6 7 1140.80 24 11.56 1996 2 2
7 13 1024.92 44 12.74 1842 2 4
8 8 0.24 165 13.97 349 2 13

Cycle 238 GMT 21/11/2022 4: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 13.87 526 2 6
2 3 1027.04 1 12.40 1822 2 2
3 12 1112.88 3 11.82 1949 2 2
4 12 2000.76 54 10.18 3200 2 2
5 7 1995.12 24 10.92 3197 2 2
6 13 1289.96 44 12.57 2225 2 3
7 13 336.36 44 13.66 850 2 11
8 8 0.04 165 14.00 349 2 15

Cycle 237 GMT 20/11/2022 1: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 13.84 526 2 6
2 3 951.64 -1 15.07 0 2 6
3 12 1098.28 54 8.34 1790 2 2
4 7 1093.24 24 11.50 1932 2 3
5 13 690.28 44 13.17 1353 2 8
6 8 0.08 165 13.94 350 2 14

Cycle 236 GMT 10/11/2022 9:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 26 13.89 512 2 5
2 12 1094.56 54 9.20 1847 2 2
3 7 1095.36 24 11.55 1939 2 2
4 13 986.04 44 12.70 1787 2 4
5 13 96.24 44 13.87 498 2 11
6 8 0.20 165 13.91 355 2 20

Cycle 235 GMT 31/10/2022 15:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 26 13.91 525 2 6
2 12 1102.68 54 9.85 1875 2 2
3 7 1102.00 24 11.70 1950 2 3
4 13 984.72 44 12.82 1776 2 5
5 13 39.00 44 14.00 404 2 11
6 8 -0.12 165 13.97 346 2 18

Cycle 234 GMT 21/10/2022 22: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 13.87 518 2 5
2 3 949.68 -1 15.10 0 2 5
3 12 1100.60 3 11.94 1938 2 2
4 12 2008.52 54 10.32 3208 2 2
5 7 2003.52 24 10.92 3219 2 2
6 13 1310.96 44 12.61 2221 2 3
7 13 234.96 44 13.78 696 2 11
8 8 0.00 165 13.99 356 2 19

Cycle 233 GMT 20/10/2022 18: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 27 13.90 507 2 5
2 12 1133.48 54 8.31 1847 2 2
3 7 1135.72 24 11.47 1988 2 2
4 13 1036.76 44 12.64 1861 2 4
5 13 151.84 44 13.84 572 2 10
6 8 0.20 165 13.96 347 2 18

Cycle 232 GMT 11/10/2022 0: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 27 13.87 524 2 5
2 12 1109.08 54 9.08 1860 2 2
3 7 1110.28 24 11.59 1954 2 2
4 13 1005.32 44 12.72 1816 2 4
5 13 112.08 44 13.88 517 2 11
6 8 0.04 165 13.95 348 2 19

Cycle 231 GMT 1/10/2022 6: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 27 13.91 516 2 5
2 12 1096.96 54 9.94 1858 2 2
3 7 1096.28 24 11.74 1935 2 3
4 13 987.92 44 12.84 1786 2 4
5 13 12.76 44 14.02 372 2 9
6 8 0.08 165 13.96 350 2 23

Cycle 230 GMT 21/ 9/2022 12:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 27 13.87 528 2 5
2 10 1010.84 4 13.05 1843 2 4
3 3 966.68 -1 15.12 0 2 4
4 12 1122.08 3 11.83 1946 2 2
5 12 1999.36 54 10.40 3195 2 2
6 7 1993.84 24 11.01 3206 2 2
7 13 1283.36 44 12.64 2210 2 3
8 13 191.52 44 13.84 645 2 11
9 8 -0.04 165 14.02 350 2 19

Cycle 229 GMT 20/ 9/2022 9: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 28 13.84 532 2 4
2 3 970.04 -1 15.11 0 2 4
3 12 1132.16 54 8.25 1837 2 2
4 7 1133.76 24 11.54 1996 2 2
5 13 1040.36 44 12.69 1871 2 3
6 13 179.24 44 13.81 619 2 10
7 8 0.04 165 13.98 349 2 16

Cycle 228 GMT 10/ 9/2022 14:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 25 13.86 521 2 4
2 3 1040.08 1 12.68 1867 2 2
3 12 1149.00 54 9.02 1909 2 2
4 7 1149.40 24 11.58 2017 2 2
5 13 1040.56 44 12.71 1868 2 4
6 13 138.84 44 13.86 567 2 10
7 8 0.04 165 13.97 352 2 15
8 14 0.04 25 14.06 351 2 20

Cycle 227 GMT 31/ 8/2022 20:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 28 13.91 513 2 4
2 3 924.16 -1 15.12 0 2 4
3 3 967.48 -1 15.12 0 2 4
4 12 1137.56 54 9.82 1928 2 2
5 7 1137.20 24 11.69 1997 2 3
6 13 1023.96 44 12.80 1851 2 4
7 13 21.88 44 14.02 388 2 8
8 8 0.00 165 13.98 353 2 15

Cycle 226 GMT 22/ 8/2022 2:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 28 13.86 531 2 5
2 12 1101.84 3 11.95 1944 2 2
3 12 2007.48 54 10.31 3216 2 2
4 7 2002.04 24 10.94 3214 2 2
5 13 1426.88 44 12.48 2379 2 3
6 13 300.60 44 13.70 799 2 11
7 8 -0.24 165 14.00 351 2 13
8 14 -0.24 25 14.12 348 2 16

Cycle 225 GMT 20/ 8/2022 23: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 28 13.89 520 2 5
2 12 1102.52 54 8.67 1844 2 2
3 7 1104.52 24 11.54 1951 2 2
4 13 1013.16 44 12.68 1822 2 4
5 13 259.84 44 13.71 731 2 11
6 8 0.28 165 13.97 346 2 22

Cycle 224 GMT 11/ 8/2022 5: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 13.89 524 2 2
2 12 1117.64 54 9.16 1879 2 2
3 7 1118.56 24 11.63 1970 2 3
4 13 1015.56 44 12.74 1828 2 4
5 13 123.04 44 13.88 540 2 11
6 8 0.12 165 13.98 348 2 14

Cycle 223 GMT 1/ 8/2022 11: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 27 13.88 522 2 5
2 3 1023.40 1 12.67 1825 2 2
3 12 1124.88 54 9.98 1906 2 2
4 7 1124.16 25 11.77 1980 2 2
5 13 1002.28 44 12.86 1816 2 4
6 13 113.08 44 13.90 530 2 11
7 8 -0.16 165 14.01 349 2 13

Cycle 222 GMT 22/ 7/2022 17: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 27 13.87 526 2 4
2 3 1021.96 1 12.45 1797 2 2
3 12 1122.04 3 12.00 1968 2 2
4 12 1998.28 54 10.43 3206 2 2
5 7 1992.32 24 11.02 3191 2 2
6 13 1397.20 44 12.51 2374 2 3
7 13 167.88 44 13.85 608 2 10
8 8 0.28 165 14.03 348 2 19
9 14 0.28 25 14.11 353 2 14

Cycle 221 GMT 21/ 7/2022 13:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 27 13.89 526 2 5
2 3 1020.80 1 12.42 1826 2 2
3 3 1013.12 1 12.08 1837 2 2
4 12 1123.44 54 8.94 1861 2 2
5 7 1125.52 24 11.59 1985 2 2
6 13 1032.80 44 12.70 1851 2 4
7 13 14.48 44 14.02 366 2 9
8 8 0.28 165 13.99 340 2 18
9 14 0.28 25 14.08 347 2 16

Cycle 220 GMT 11/ 7/2022 19:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 13.90 518 2 5
2 3 966.16 -1 15.13 0 2 5
3 3 1016.36 1 12.20 1818 2 2
4 12 1152.52 54 9.14 1921 2 2
5 7 1153.20 24 11.65 2018 2 2
6 13 1043.68 44 12.76 1867 2 4
7 13 29.56 44 14.01 398 2 10
8 8 -0.12 165 14.01 349 2 29

Cycle 219 GMT 2/ 7/2022 1:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 27 13.94 522 2 5
2 3 1022.12 1 12.62 1807 2 2
3 12 1127.84 54 10.06 1906 2 2
4 7 1127.28 24 11.76 1984 2 2
5 13 1003.60 44 12.87 1812 2 5
6 8 0.60 165 14.00 351 2 17

Cycle 218 GMT 22/ 6/2022 7:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 26 13.90 517 2 3
2 3 1016.96 1 12.41 1825 2 2
3 12 1120.52 3 12.15 1936 2 2
4 12 2003.88 54 10.47 3205 2 2
5 7 1998.68 24 11.02 3220 2 2
6 13 1277.64 44 12.67 2168 2 3
7 13 316.04 44 13.68 833 2 10
8 8 0.16 165 14.02 351 2 18

Cycle 217 GMT 21/ 6/2022 4: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 26 13.87 519 2 5
2 3 1038.88 1 12.62 1856 2 3
3 12 1132.12 54 9.30 1887 2 2
4 7 1132.28 24 11.65 1986 2 2
5 13 1023.56 44 12.73 1845 2 4
6 13 133.44 44 13.86 552 2 11
7 8 -0.52 165 13.99 344 2 18
8 14 -0.52 25 14.09 345 2 22

Cycle 216 GMT 11/ 6/2022 9:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 26 13.88 520 2 6
2 3 1031.40 1 12.67 1862 2 2
3 12 1208.48 54 9.53 2017 2 2
4 7 1208.32 24 11.64 2093 2 2
5 13 1081.96 44 12.75 1917 2 4
6 13 78.80 44 13.95 470 2 11
7 8 -0.12 165 14.02 343 2 20

Cycle 215 GMT 1/ 6/2022 15:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 27 13.84 523 2 4
2 3 944.40 -1 15.14 0 2 4
3 12 1141.84 54 10.16 1943 2 2
4 7 1140.04 24 11.77 1997 2 3
5 13 1006.48 44 12.86 1817 2 5
6 8 0.48 165 13.95 356 2 15

Cycle 214 GMT 22/ 5/2022 21:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 25 13.88 530 2 4
2 3 1043.24 2 12.71 1852 2 2
3 12 1112.28 3 12.17 1966 2 2
4 12 1988.60 54 10.66 3198 2 2
5 7 1982.00 24 11.09 3185 2 2
6 13 1377.08 44 12.53 2331 2 3
7 13 278.08 44 13.71 762 2 10
8 13 18.56 44 14.03 389 2 12
9 8 -0.16 165 13.98 358 2 16

Cycle 213 GMT 21/ 5/2022 17:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 13.89 516 2 6
2 3 969.48 -1 15.14 0 2 6
3 12 1108.12 54 9.18 1886 2 2
4 7 1108.68 24 11.59 1967 2 2
5 13 1001.88 44 12.74 1818 2 5
6 13 210.96 44 13.75 655 2 11
7 13 12.72 44 14.02 366 2 10
8 8 0.24 165 13.95 344 2 16
9 14 0.24 25 14.04 349 2 17

Cycle 212 GMT 11/ 5/2022 23:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 26 13.89 520 2 6
2 3 1013.60 1 12.38 1840 2 2
3 3 1013.84 1 12.16 1851 2 2
4 12 1137.96 54 9.57 1932 2 2
5 7 1137.16 24 11.69 2000 2 3
6 13 1014.88 44 12.77 1830 2 5
7 13 199.48 44 13.78 647 2 12
8 8 -0.32 165 13.98 348 2 17

Cycle 211 GMT 2/ 5/2022 6: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 25 13.90 511 2 6
2 3 1022.60 1 12.65 1830 2 2
3 12 1132.96 54 10.15 1936 2 2
4 7 1131.80 24 11.79 1992 2 3
5 13 1009.32 44 12.83 1821 2 5
6 8 0.08 165 13.95 358 2 15

Cycle 210 GMT 22/ 4/2022 12:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 26 13.88 522 2 6
2 3 960.64 -1 15.14 0 2 6
3 12 1103.80 3 12.16 1954 2 2
4 12 1995.16 54 10.51 3194 2 2
5 7 1989.52 24 11.06 3208 2 2
6 13 1406.04 44 12.48 2349 2 3
7 13 423.60 44 13.53 970 2 11
8 8 0.16 165 13.97 353 2 17

Cycle 209 GMT 21/ 4/2022 8:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 26 13.87 517 2 5
2 3 1028.56 1 12.59 1844 2 2
3 12 1112.80 54 9.48 1905 2 2
4 7 1112.44 24 11.63 1961 2 2
5 13 997.52 44 12.71 1802 2 5
6 13 96.48 44 13.89 496 2 11
7 8 0.32 165 13.95 351 2 15

Cycle 208 GMT 11/ 4/2022 14:39:15

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 27 13.89 527 2 4
2 3 956.44 -1 15.15 0 2 4
3 12 1127.36 54 9.61 1928 2 2
4 7 1126.60 24 11.68 1982 2 3
5 13 1011.36 44 12.76 1826 2 4
6 13 61.36 44 13.96 444 2 10
7 8 0.20 165 13.98 348 2 14

Cycle 207 GMT 1/ 4/2022 20:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 26 13.87 523 2 6
2 10 1003.80 4 13.16 1831 2 4
3 3 938.56 -1 15.17 0 2 4
4 12 1081.48 54 10.26 1868 2 2
5 7 1080.08 24 11.86 1918 2 3
6 13 960.88 44 12.87 1750 2 6
7 13 57.40 44 13.95 443 2 12
8 8 -0.12 165 13.97 352 2 18
9 14 -0.12 25 14.05 350 2 18

Cycle 206 GMT 23/ 3/2022 2:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 25 13.89 515 2 6
2 3 1023.96 1 12.55 1831 2 2
3 3 1019.48 1 12.26 1827 2 2
4 12 1106.64 3 12.16 1965 2 2
5 12 1998.20 54 10.64 3199 2 2
6 7 1992.60 24 11.07 3209 2 2
7 13 1399.60 44 12.50 2334 2 3
8 13 140.92 44 13.88 556 2 12
9 8 0.20 165 14.00 345 2 14

Cycle 205 GMT 21/ 3/2022 23:20: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 25 13.85 525 2 6
2 12 1155.24 54 9.39 1950 2 2
3 7 1155.12 24 11.58 2025 2 2
4 13 1048.44 44 12.62 1880 2 4
5 13 132.16 44 13.84 549 2 12
6 8 0.00 165 13.95 349 2 14

Cycle 204 GMT 12/ 3/2022 5:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 26 13.89 514 2 6
2 12 1136.68 54 9.64 1936 2 2
3 7 1135.80 24 11.68 1992 2 3
4 13 1018.20 44 12.71 1834 2 5
5 13 56.88 44 13.92 449 2 12
6 8 0.36 165 13.93 361 2 21

Cycle 203 GMT 2/ 3/2022 11:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 26 13.88 525 2 6
2 12 1110.20 54 10.21 1922 2 2
3 7 1108.36 24 11.82 1954 2 3
4 13 976.60 44 12.85 1758 2 6
5 8 -0.20 165 13.92 356 2 17

Cycle 202 GMT 20/ 2/2022 17:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 25 13.87 521 2 6
2 12 1118.96 3 12.19 1961 2 2
3 12 1987.60 54 10.59 3186 2 2
4 7 1981.76 24 11.11 3191 2 2
5 13 1374.16 44 12.51 2298 2 3
6 13 262.76 44 13.70 743 2 12
7 8 -0.08 165 13.96 356 2 17

Cycle 201 GMT 19/ 2/2022 13:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 26 13.84 519 2 6
2 3 970.92 -1 15.16 0 2 6
3 12 1126.64 54 9.52 1921 2 2
4 7 1125.88 24 11.58 1979 2 3
5 13 1011.64 44 12.64 1819 2 5
6 13 28.76 44 13.96 400 2 11
7 8 0.44 165 13.92 351 2 19

Cycle 200 GMT 9/ 2/2022 19:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 26 13.86 540 2 6
2 12 1117.80 54 9.66 1912 2 2
3 7 1116.80 24 11.66 1970 2 3
4 13 986.96 44 12.71 1796 2 5
5 13 42.08 44 13.93 431 2 12
6 8 0.12 165 13.91 367 2 13

Cycle 199 GMT 31/ 1/2022 1:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 26 13.90 530 2 6
2 12 1116.48 54 10.26 1925 2 2
3 7 1114.52 25 11.79 1959 2 3
4 13 983.92 44 12.81 1778 2 5
5 8 0.04 165 13.93 356 2 14

Cycle 198 GMT 21/ 1/2022 7:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 26 13.86 528 2 6
2 3 971.08 -1 15.18 0 2 6
3 12 1127.60 3 12.16 1985 2 2
4 12 1985.56 54 10.62 3191 2 2
5 7 1979.52 24 11.11 3189 2 2
6 13 1230.28 44 12.65 2099 2 4
7 13 135.64 44 13.86 553 2 12
8 8 0.12 165 13.96 356 2 19

Cycle 197 GMT 20/ 1/2022 3:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 26 13.86 524 2 6
2 12 1141.68 54 9.41 1945 2 2
3 7 1140.32 24 11.55 1999 2 3
4 13 1017.64 44 12.62 1827 2 5
5 13 117.24 44 13.84 526 2 12
6 8 -0.28 165 13.92 352 2 13

Cycle 196 GMT 10/ 1/2022 9:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 26 13.88 522 2 6
2 12 1138.48 54 9.60 1946 2 2
3 7 1137.44 24 11.63 2000 2 3
4 13 1013.28 44 12.69 1807 2 5
5 13 22.20 44 13.95 400 2 11
6 8 0.32 165 13.90 358 2 16

Cycle 195 GMT 31/12/2021 15:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 27 13.85 531 2 6
2 12 1100.20 54 10.25 1910 2 2
3 7 1098.16 24 11.77 1956 2 3
4 13 969.92 44 12.76 1768 2 6
5 8 0.20 165 13.86 371 2 19

Cycle 194 GMT 21/12/2021 21:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 26 13.85 532 2 6
2 12 1116.40 3 12.23 1962 2 2
3 12 1985.12 54 10.60 3196 2 2
4 7 1979.56 24 11.08 3199 2 2
5 13 1244.12 44 12.60 2139 2 4
6 13 151.36 44 13.83 581 2 11
7 8 0.08 165 13.95 357 2 19

Cycle 193 GMT 20/12/2021 17:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 26 13.84 519 2 6
2 3 973.32 -1 15.21 0 2 6
3 12 1145.96 54 9.28 1955 2 2
4 7 1144.88 24 11.48 2009 2 3
5 13 1031.96 44 12.54 1835 2 4
6 13 125.40 44 13.79 556 2 12
7 8 0.00 165 13.87 366 2 16

Cycle 192 GMT 10/12/2021 23:46: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 25 13.86 531 2 7
2 3 1040.32 1 12.50 1871 2 2
3 12 1136.68 54 9.44 1948 2 2
4 7 1135.80 25 11.48 1999 2 3
5 13 1020.72 44 12.57 1819 2 4
6 13 12.72 44 13.96 384 2 12
7 8 0.20 165 13.87 364 2 17

Cycle 191 GMT 1/12/2021 5:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 26 13.90 525 2 7
2 12 1094.80 54 10.05 1899 2 2
3 7 1092.96 24 11.71 1942 2 3
4 13 964.04 44 12.70 1758 2 6
5 8 0.04 165 13.87 369 2 20

Cycle 190 GMT 21/11/2021 11:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 25 13.92 525 2 7
2 12 1107.40 5 12.49 1986 2 2
3 12 1911.24 54 10.89 3094 2 2
4 7 1904.80 24 11.27 3085 2 2
5 13 1031.56 44 12.94 1794 2 5
6 13 114.28 44 13.90 528 2 13
7 8 -0.08 165 13.96 364 2 15

Cycle 189 GMT 20/11/2021 7:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 26 13.88 530 2 7
2 12 1104.16 6 9.04 1872 2 2
3 12 1990.92 80 7.80 3079 2 2
4 12 1980.24 54 8.18 3134 2 2
5 7 1972.96 24 10.78 3186 2 2
6 13 844.64 44 13.06 1557 2 7
7 8 -0.12 165 13.93 367 2 15

Cycle 188 GMT 10/11/2021 7: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 26 13.89 529 2 7
2 12 1112.20 6 9.40 1889 2 2
3 12 1978.96 80 7.91 3092 2 2
4 12 1968.44 54 8.20 3114 2 2
5 7 1961.36 24 10.88 3172 2 2
6 13 677.88 44 13.26 1322 2 8
7 8 -0.16 165 13.94 368 2 18

Cycle 187 GMT 31/10/2021 6:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 26 13.90 528 2 7
2 12 1122.32 7 9.60 1918 2 2
3 12 1966.92 72 7.96 3074 2 2
4 7 1962.96 24 10.78 3155 2 2
5 13 1531.92 36 12.41 2583 2 3
6 13 486.68 36 13.51 1067 2 10
7 8 0.36 165 13.93 366 2 17

Cycle 186 GMT 21/10/2021 5: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 26 13.93 515 2 7
2 12 1103.36 7 9.69 1878 2 2
3 12 1949.84 72 8.04 3037 2 2
4 7 1945.24 24 10.75 3131 2 2
5 13 1511.04 36 12.42 2544 2 3
6 13 438.48 36 13.55 996 2 10
7 8 0.16 165 13.94 366 2 14

Cycle 185 GMT 11/10/2021 4: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 26 13.91 525 2 7
2 12 1122.84 7 9.57 1897 2 2
3 12 1967.24 72 8.07 3078 2 2
4 7 1962.84 24 10.77 3166 2 2
5 13 1403.80 36 12.59 2368 2 4
6 13 499.64 36 13.51 1076 2 10
7 8 0.40 165 13.94 364 2 12

Cycle 184 GMT 1/10/2021 2:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 26 13.93 531 2 7
2 12 1121.08 7 9.40 1908 2 2
3 12 1970.84 72 8.06 3082 2 2
4 7 1966.60 24 10.78 3161 2 2
5 13 1550.64 36 12.43 2600 2 3
6 13 617.36 36 13.40 1259 2 10
7 8 -0.32 165 13.95 365 2 14

Cycle 183 GMT 21/ 9/2021 1:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 26 13.94 523 2 7
2 12 1116.20 7 9.48 1890 2 2
3 12 1977.44 72 8.00 3063 2 2
4 7 1973.20 24 10.80 3181 2 2
5 13 1412.60 36 12.61 2389 2 3
6 13 656.20 36 13.37 1311 2 9
7 8 0.32 165 13.94 369 2 16

Cycle 182 GMT 11/ 9/2021 0:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 26 13.97 519 2 6
2 12 1086.80 7 9.60 1856 2 2
3 12 1956.04 63 8.04 3058 2 2
4 7 1952.16 24 10.80 3134 2 2
5 13 1544.60 36 12.42 2583 2 3
6 13 628.96 36 13.40 1274 2 9
7 8 -0.08 165 13.94 367 2 14

Cycle 181 GMT 31/ 8/2021 23:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 26 13.94 525 2 6
2 12 1109.16 7 9.52 1899 2 2
3 12 1968.68 63 8.16 3051 2 2
4 7 1964.40 24 10.83 3157 2 2
5 13 1543.12 36 12.41 2596 2 3
6 13 519.88 36 13.49 1119 2 10
7 13 17.56 36 14.05 394 2 12
8 8 0.16 165 13.97 360 2 18

Cycle 180 GMT 21/ 8/2021 22:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 26 13.94 525 2 7
2 12 1116.32 7 9.52 1892 2 2
3 12 1982.88 63 8.05 3090 2 2
4 7 1978.80 24 10.85 3175 2 2
5 13 1568.72 36 12.40 2638 2 3
6 13 549.04 36 13.47 1147 2 9
7 8 0.36 165 13.97 361 2 16

Cycle 179 GMT 11/ 8/2021 20:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 26 13.96 518 2 7
2 12 1090.24 7 9.49 1849 2 2
3 12 1974.00 63 8.18 3056 2 2
4 7 1969.96 24 10.85 3173 2 2
5 13 1562.00 36 12.40 2631 2 3
6 13 646.92 36 13.39 1281 2 9
7 8 -0.16 165 13.97 357 2 16

Cycle 178 GMT 1/ 8/2021 19:52: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 26 13.94 538 2 7
2 12 1120.00 7 9.32 1899 2 2
3 12 1994.48 63 8.06 3098 2 2
4 7 1990.60 24 10.87 3199 2 2
5 13 1716.20 36 12.28 2854 2 3
6 13 538.32 36 13.48 1151 2 10
7 8 0.44 165 13.96 365 2 20

Cycle 177 GMT 22/ 7/2021 18:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 26 13.96 525 2 7
2 12 1100.52 7 9.57 1879 2 2
3 12 1988.68 63 8.08 3092 2 2
4 7 1984.92 24 10.86 3186 2 2
5 13 1718.24 36 12.24 2843 2 3
6 13 778.08 36 13.29 1471 2 8
7 13 12.92 36 14.06 394 2 12
8 8 0.00 165 13.95 364 2 19

Cycle 176 GMT 12/ 7/2021 17:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 25 13.95 521 2 7
2 12 1111.32 7 9.39 1880 2 2
3 12 1999.76 63 8.06 3109 2 2
4 7 1995.84 24 10.92 3215 2 2
5 13 1580.84 36 12.45 2658 2 3
6 13 815.16 36 13.26 1521 2 8
7 8 -0.20 165 13.95 372 2 20

Cycle 175 GMT 2/ 7/2021 17: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 25 13.97 533 2 7
2 12 1116.76 7 9.61 1906 2 2
3 12 1993.32 63 8.31 3103 2 2
4 7 1989.48 24 10.89 3215 2 2
5 13 1579.00 36 12.46 2656 2 3
6 13 793.92 36 13.27 1497 2 8
7 8 0.40 165 13.97 364 2 15

Cycle 174 GMT 22/ 6/2021 16: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 25 13.97 533 2 7
2 12 1118.92 7 9.28 1892 2 2
3 12 1992.20 59 8.14 3095 2 2
4 7 1988.24 24 10.92 3209 2 2
5 13 1583.08 36 12.45 2653 2 3
6 13 814.84 36 13.26 1529 2 8
7 13 77.80 36 13.98 486 2 13
8 8 -0.04 165 13.98 366 2 16

Cycle 173 GMT 12/ 6/2021 14:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 25 14.03 523 2 6
2 12 1110.64 7 9.81 1887 2 2
3 12 2001.12 59 8.29 3121 2 2
4 7 1997.84 24 10.91 3211 2 2
5 13 1861.28 36 12.09 3039 2 2
6 13 933.84 36 13.17 1683 2 7
7 13 55.48 36 14.01 445 2 11
8 8 0.16 165 13.98 368 2 18

Cycle 172 GMT 2/ 6/2021 14:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 25 14.00 518 2 6
2 12 1124.76 7 9.52 1900 2 2
3 12 1985.96 59 8.47 3070 2 2
4 7 1981.60 24 10.96 3191 2 2
5 13 1699.16 36 12.35 2801 2 3
6 13 626.28 36 13.42 1264 2 9
7 8 0.04 165 13.99 357 2 17

Cycle 171 GMT 23/ 5/2021 13:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 25 14.02 514 2 6
2 12 1121.96 7 9.73 1896 2 2
3 12 1999.84 56 8.46 3110 2 2
4 7 1995.88 24 10.98 3212 2 2
5 13 1719.84 36 12.33 2845 2 3
6 13 798.56 36 13.30 1493 2 8
7 8 -0.08 165 13.99 361 2 18

Cycle 170 GMT 13/ 5/2021 12:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 25 14.02 521 2 7
2 12 1121.52 7 9.42 1905 2 2
3 12 2001.80 56 8.41 3120 2 2
4 7 1998.16 24 10.99 3198 2 2
5 13 1732.84 36 12.32 2863 2 3
6 13 682.60 36 13.39 1335 2 9
7 13 50.08 36 14.03 432 2 12
8 8 0.24 165 14.00 360 2 14

Cycle 169 GMT 3/ 5/2021 11:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 25 14.03 526 2 7
2 12 1101.60 7 9.78 1882 2 2
3 12 1993.88 56 8.45 3110 2 2
4 7 1989.96 24 10.98 3197 2 2
5 13 1719.84 36 12.31 2850 2 3
6 13 787.08 36 13.29 1482 2 8
7 8 -0.24 165 13.99 358 2 17

Cycle 168 GMT 23/ 4/2021 10:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 25 14.04 529 2 7
2 12 1106.88 7 9.86 1879 2 2
3 12 2000.12 56 8.58 3114 2 2
4 7 1996.24 24 11.00 3216 2 2
5 13 1585.80 36 12.49 2656 2 3
6 13 672.08 36 13.39 1337 2 9
7 8 0.28 165 14.00 360 2 17

Cycle 167 GMT 13/ 4/2021 9:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 24 14.04 521 2 6
2 3 1025.96 1 12.83 1848 2 2
3 12 1123.44 7 9.21 1887 2 2
4 12 1998.48 56 8.58 3100 2 2
5 7 1994.16 24 11.01 3236 2 2
6 13 1579.72 36 12.51 2645 2 3
7 13 690.04 36 13.37 1365 2 10
8 8 0.12 165 13.99 363 2 18

Cycle 166 GMT 3/ 4/2021 9:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 25 14.05 530 2 4
2 12 1108.76 7 9.58 1887 2 2
3 12 2000.16 52 8.65 3096 2 2
4 7 1996.32 24 11.04 3196 2 2
5 13 1723.84 35 12.32 2855 2 2
6 13 683.56 35 13.37 1352 2 7
7 8 -0.12 165 13.98 367 2 14

Cycle 165 GMT 24/ 3/2021 7:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 25 14.07 524 2 5
2 12 1108.56 7 9.51 1891 2 2
3 12 1999.32 52 8.58 3132 2 2
4 7 1995.84 24 11.04 3209 2 2
5 13 1598.84 35 12.48 2681 2 3
6 13 710.08 35 13.35 1383 2 8
7 8 -0.12 165 14.01 360 2 21
8 14 -0.12 75 14.04 354 2 16

Cycle 164 GMT 14/ 3/2021 7:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 26 14.08 514 2 5
2 3 971.84 -1 15.27 0 2 5
3 12 1110.96 7 9.59 1898 2 2
4 12 1999.80 52 8.74 3112 2 2
5 7 1995.84 24 11.07 3202 2 2
6 13 1720.12 35 12.35 2853 2 3
7 13 781.12 35 13.30 1485 2 8
8 13 28.44 35 14.06 411 2 12
9 8 -0.12 165 14.01 357 2 22

Cycle 163 GMT 4/ 3/2021 6:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 26 14.04 531 2 6
2 12 1092.68 5 8.38 1854 2 2
3 12 2001.72 52 8.70 3103 2 2
4 7 1998.00 24 11.09 3205 2 2
5 13 1719.56 35 12.34 2856 2 3
6 13 807.60 35 13.28 1527 2 8
7 13 16.36 35 14.10 389 2 12
8 8 -0.04 165 13.99 359 2 18

Cycle 162 GMT 22/ 2/2021 6:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 27 14.03 542 2 5
2 3 942.56 -1 15.27 0 2 5
3 12 1082.96 5 8.50 1833 2 2
4 12 2005.36 52 8.73 3095 2 2
5 7 2002.04 24 11.07 3220 2 2
6 13 1597.52 35 12.53 2676 2 3
7 13 711.52 35 13.37 1370 2 9
8 8 0.04 165 14.00 360 2 17

Cycle 161 GMT 12/ 2/2021 6: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 25 14.06 541 2 6
2 3 1056.20 1 13.05 1891 2 2
3 3 1028.52 1 12.74 1854 2 2
4 12 1134.20 5 8.52 1899 2 2
5 12 2001.08 52 8.88 3138 2 2
6 7 1997.48 24 11.16 3222 2 2
7 13 1861.48 35 12.22 3040 2 2
8 13 1064.08 35 13.09 1869 2 7
9 8 -0.12 165 14.02 362 2 15
10 14 -0.12 75 14.06 358 2 21

Cycle 160 GMT 2/ 2/2021 6:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 25 14.04 524 2 6
2 12 1123.04 4 6.24 2272 2 2
3 12 2001.80 50 8.86 3155 2 2
4 7 1998.44 24 11.15 3209 2 2
5 13 1860.88 35 12.22 3034 2 2
6 13 935.28 35 13.20 1688 2 7
7 13 33.12 35 14.06 411 2 12
8 8 0.44 165 14.01 357 2 19

Cycle 159 GMT 23/ 1/2021 6:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 25 14.07 521 2 7
2 12 1096.40 4 8.28 1864 2 2
3 12 2000.40 50 8.95 3102 2 2
4 7 1996.68 24 11.16 3214 2 2
5 13 1722.76 35 12.39 2847 2 3
6 13 810.44 35 13.28 1515 2 7
7 8 -0.12 165 14.01 358 2 18

Cycle 158 GMT 13/ 1/2021 6:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 26 14.06 535 2 6
2 12 1109.80 4 8.09 1870 2 2
3 12 2000.16 41 8.82 3138 2 2
4 7 1996.88 24 11.17 3215 2 2
5 13 1860.52 35 12.20 3035 2 2
6 13 956.48 35 13.15 1724 2 7
7 13 81.28 35 14.00 485 2 12
8 8 0.00 165 14.01 356 2 17

Cycle 157 GMT 3/ 1/2021 6:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 26 14.06 515 2 7
2 12 1120.28 4 8.38 1881 2 2
3 12 2004.76 41 9.02 3096 2 2
4 7 2001.84 24 11.15 3227 2 2
5 13 1866.20 35 12.17 3052 2 2
6 13 1107.48 35 13.04 1923 2 6
7 13 76.00 35 13.99 484 2 11
8 8 0.16 165 14.00 365 2 16

Cycle 156 GMT 24/12/2020 6:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 26 14.07 514 2 7
2 12 1097.84 4 8.57 1858 2 2
3 12 2000.92 41 9.08 3088 2 2
4 7 1997.52 24 11.20 3214 2 2
5 13 1732.56 35 12.38 2865 2 3
6 13 852.20 35 13.25 1569 2 7
7 8 0.40 165 13.99 361 2 17

Cycle 155 GMT 14/12/2020 5:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 26 14.04 542 2 7
2 12 1116.76 4 8.94 1897 2 2
3 12 2001.80 41 9.13 3112 2 2
4 7 1998.44 24 11.25 3222 2 2
5 13 1733.92 35 12.38 2879 2 3
6 13 967.20 35 13.15 1749 2 7
7 8 0.48 165 13.98 360 2 16

Cycle 154 GMT 4/12/2020 5:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 26 14.06 526 2 7
2 12 1095.12 4 9.06 1861 2 2
3 12 2003.12 37 9.11 3113 2 2
4 7 2000.16 24 11.21 3230 2 2
5 13 1733.20 35 12.38 2864 2 3
6 13 861.60 35 13.24 1592 2 7
7 13 108.48 35 13.96 527 2 13
8 8 -0.32 165 13.99 359 2 7

Cycle 153 GMT 24/11/2020 5:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 26 14.01 534 2 7
2 3 1023.96 1 12.69 1846 2 2
3 12 1115.52 4 9.52 1880 2 2
4 12 2003.44 37 9.21 3116 2 2
5 7 2000.48 24 11.30 3217 2 2
6 13 1734.64 35 12.40 2869 2 3
7 13 865.28 35 13.24 1594 2 7
8 8 0.24 165 13.97 366 2 20

Cycle 152 GMT 14/11/2020 4:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 26 14.06 528 2 7
2 12 1099.96 4 9.78 1883 2 2
3 12 2002.24 37 9.25 3113 2 2
4 7 1999.28 24 11.27 3224 2 2
5 13 1865.00 35 12.22 3045 2 2
6 13 1089.68 35 13.05 1896 2 6
7 13 132.04 35 13.92 566 2 12
8 8 -0.04 165 13.98 366 2 8

Cycle 151 GMT 4/11/2020 4:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 26 14.02 535 2 7
2 12 1098.32 4 9.74 1876 2 2
3 12 2000.36 37 9.29 3104 2 2
4 7 1997.12 24 11.33 3213 2 2
5 13 1739.24 35 12.40 2882 2 3
6 13 840.04 35 13.24 1564 2 8
7 13 22.68 35 14.06 411 2 10
8 8 0.12 165 13.96 371 2 19

Cycle 150 GMT 25/10/2020 4:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 26 14.05 533 2 7
2 12 1106.80 4 10.17 1917 2 2
3 12 2000.48 37 9.28 3117 2 2
4 7 1997.04 24 11.31 3231 2 2
5 13 1714.24 35 12.42 2839 2 3
6 13 829.88 35 13.27 1548 2 8
7 13 22.28 35 14.04 413 2 11
8 8 -0.24 165 13.94 374 2 22

Cycle 149 GMT 15/10/2020 3:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 27 14.04 522 2 7
2 12 1082.96 4 10.80 1873 2 2
3 12 2000.92 37 9.37 3121 2 2
4 7 1997.56 24 11.32 3217 2 2
5 13 1599.32 35 12.55 2684 2 3
6 13 755.12 35 13.33 1444 2 8
7 8 0.24 165 13.96 369 2 16

Cycle 148 GMT 5/10/2020 2:46: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 26 14.05 536 2 7
2 3 1022.00 1 12.24 1870 2 2
3 12 1116.04 4 10.86 1927 2 2
4 12 1999.52 37 9.54 3097 2 2
5 7 1995.80 24 11.38 3212 2 2
6 13 1716.32 35 12.43 2847 2 3
7 13 705.92 35 13.37 1378 2 9
8 8 0.16 165 13.98 361 2 15

Cycle 147 GMT 25/ 9/2020 1:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 26 14.07 543 2 7
2 12 1108.44 4 11.13 1924 2 2
3 12 2002.48 37 9.40 3137 2 2
4 7 1999.12 24 11.39 3233 2 2
5 13 1737.12 35 12.42 2882 2 3
6 13 992.04 35 13.11 1785 2 7
7 8 0.36 165 13.98 361 2 18

Cycle 146 GMT 15/ 9/2020 0:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 14.08 527 2 7
2 3 973.36 -1 15.26 0 2 7
3 12 1133.16 4 11.19 1953 2 2
4 12 2001.36 37 9.68 3102 2 2
5 7 1998.20 24 11.40 3215 2 2
6 13 1862.20 35 12.24 3049 2 2
7 13 964.88 35 13.14 1742 2 7
8 13 96.36 35 13.98 517 2 13
9 8 0.04 165 14.02 358 2 15

Cycle 145 GMT 5/ 9/2020 0: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 24 14.06 543 2 6
2 10 1030.92 3 13.19 1879 2 4
3 12 1099.88 4 11.16 1899 2 2
4 12 2002.76 37 9.75 3117 2 2
5 7 1999.68 24 11.45 3216 2 2
6 13 1729.08 35 12.43 2862 2 3
7 13 827.44 35 13.27 1532 2 7
8 8 0.28 165 14.00 358 2 15

Cycle 144 GMT 25/ 8/2020 23:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 25 14.07 532 2 6
2 12 1100.56 4 11.20 1923 2 2
3 12 2003.16 37 9.72 3133 2 2
4 7 2000.52 24 11.48 3216 2 2
5 13 1872.72 35 12.26 3068 2 2
6 13 796.96 35 13.28 1494 2 7
7 13 40.36 35 14.06 421 2 12
8 8 -0.20 165 13.99 354 2 15

Cycle 143 GMT 15/ 8/2020 23:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 25 14.09 526 2 7
2 12 1098.76 4 11.28 1912 2 2
3 12 2000.80 37 9.93 3107 2 2
4 7 1997.48 24 11.52 3217 2 2
5 13 1603.56 35 12.54 2690 2 3
6 13 725.72 35 13.34 1405 2 8
7 8 1.52 165 13.99 363 2 14
8 14 1.52 75 13.98 359 2 14

Cycle 142 GMT 5/ 8/2020 22:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 26 14.04 538 2 7
2 12 1104.28 4 11.47 1916 2 2
3 12 2001.04 37 9.99 3128 2 2
4 7 1997.44 24 11.57 3216 2 2
5 13 1590.36 35 12.56 2653 2 4
6 13 711.52 35 13.36 1373 2 9
7 13 20.44 35 14.09 396 2 12
8 8 -0.16 165 13.99 354 2 19

Cycle 141 GMT 26/ 7/2020 21:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 26 14.01 534 2 7
2 12 1124.56 4 11.38 1951 2 2
3 12 1996.12 37 10.14 3129 2 2
4 7 1992.60 24 11.52 3209 2 2
5 13 1722.44 35 12.44 2853 2 3
6 13 822.32 35 13.25 1539 2 8
7 8 0.08 165 14.00 356 2 19

Cycle 140 GMT 16/ 7/2020 20:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 26 14.07 524 2 7
2 3 966.88 -1 15.27 0 2 7
3 12 1128.16 4 11.56 1953 2 2
4 12 1991.32 37 10.34 3134 2 2
5 7 1987.72 24 11.50 3217 2 2
6 13 1583.48 35 12.55 2660 2 3
7 13 820.80 35 13.26 1528 2 8
8 8 0.32 165 13.96 369 2 24
9 14 0.32 75 13.95 363 2 20

Cycle 139 GMT 6/ 7/2020 18:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 25 14.04 542 2 7
2 3 1059.76 2 12.85 1916 2 3
3 12 1097.72 4 11.66 1912 2 2
4 12 1974.40 37 10.37 3130 2 2
5 7 1969.72 24 11.48 3196 2 2
6 13 1541.20 35 12.59 2610 2 4
7 13 647.76 35 13.40 1299 2 8
8 8 0.08 165 13.98 368 2 17

Cycle 138 GMT 26/ 6/2020 17:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 26 14.03 533 2 6
2 3 955.40 -1 15.27 0 2 6
3 12 1123.56 4 11.50 1940 2 2
4 12 1983.00 37 10.31 3114 2 2
5 7 1978.84 24 11.50 3204 2 2
6 13 1694.56 35 12.43 2825 2 3
7 13 787.36 35 13.28 1493 2 8
8 8 0.36 165 13.97 364 2 17

Cycle 137 GMT 16/ 6/2020 16:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 25 14.06 528 2 7
2 12 1120.40 4 11.65 1950 2 2
3 12 1988.60 37 10.42 3153 2 2
4 7 1984.88 24 11.52 3203 2 2
5 13 1443.56 35 12.68 2422 2 4
6 13 706.40 35 13.35 1382 2 9
7 13 47.36 35 14.04 439 2 13
8 8 0.16 165 13.96 364 2 17

Cycle 136 GMT 6/ 6/2020 15:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 27 14.04 528 2 7
2 3 950.24 -1 15.27 0 2 7
3 12 1107.76 4 11.71 1923 2 2
4 12 1990.00 37 10.47 3148 2 2
5 7 1986.80 25 11.49 3209 2 2
6 13 1579.84 35 12.55 2659 2 4
7 13 703.80 35 13.34 1378 2 10
8 8 -0.12 165 13.99 361 2 22

Cycle 135 GMT 27/ 5/2020 14: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 24 14.05 540 2 7
2 3 1067.24 2 12.93 1913 2 3
3 3 1029.04 1 12.85 1868 2 2
4 12 1100.76 4 11.68 1922 2 2
5 12 1987.32 37 10.52 3143 2 2
6 7 1983.76 24 11.50 3204 2 2
7 13 1568.00 35 12.54 2639 2 3
8 13 691.80 35 13.36 1359 2 9
9 8 0.24 165 13.98 363 2 16

Cycle 134 GMT 17/ 5/2020 12:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 24 14.10 520 2 4
2 12 1161.72 4 11.65 2009 2 2
3 12 2000.00 37 10.54 3181 2 2
4 7 1996.40 24 11.49 3217 2 2
5 13 1564.20 35 12.56 2629 2 3
6 13 642.28 35 13.41 1287 2 9
7 8 0.12 165 14.01 355 2 16

Cycle 133 GMT 7/ 5/2020 12:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 25 14.08 525 2 6
2 3 954.36 -1 15.28 0 2 6
3 12 1124.04 4 11.75 1954 2 2
4 12 1984.52 37 10.57 3143 2 2
5 7 1980.32 24 11.52 3197 2 2
6 13 1556.44 35 12.56 2620 2 3
7 13 657.64 35 13.38 1321 2 9
8 8 1.20 165 13.98 363 2 15

Cycle 132 GMT 27/ 4/2020 11: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 26 14.05 538 2 5
2 12 1066.48 4 11.74 1879 2 2
3 12 2005.12 37 10.55 3158 2 2
4 7 2002.60 24 11.46 3224 2 2
5 13 1881.00 35 12.25 3078 2 2
6 13 800.12 35 13.27 1498 2 7
7 13 80.28 35 14.00 487 2 12
8 8 0.04 165 13.98 359 2 26

Cycle 131 GMT 17/ 4/2020 10: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 26 14.05 534 2 7
2 12 1132.56 4 11.80 1959 2 2
3 12 1985.92 37 10.57 3158 2 2
4 7 1982.12 24 11.46 3200 2 2
5 13 1561.72 35 12.56 2616 2 4
6 13 823.80 35 13.27 1532 2 8
7 8 0.36 165 14.00 353 2 15
8 14 0.36 75 13.98 346 2 23

Cycle 130 GMT 7/ 4/2020 8:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 22 14.09 529 2 6
2 3 1083.48 2 12.98 1939 2 4
3 3 1047.28 1 13.11 1895 2 2
4 12 1091.88 4 11.79 1898 2 2
5 12 1984.32 37 10.65 3129 2 2
6 7 1980.04 24 11.44 3199 2 2
7 13 1544.48 35 12.59 2565 2 3
8 13 658.96 35 13.38 1326 2 10
9 8 -0.16 165 13.98 362 2 22

Cycle 129 GMT 28/ 3/2020 7:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 25 14.08 519 2 6
2 3 931.36 -1 15.27 0 2 6
3 3 964.40 -1 15.26 0 2 6
4 12 1222.48 4 11.71 2098 2 2
5 12 1982.56 37 10.59 3140 2 2
6 7 1981.72 24 11.45 3190 2 2
7 13 1855.96 35 12.24 3040 2 3
8 13 1072.44 35 13.04 1892 2 7
9 8 0.44 165 14.03 352 2 17

Cycle 128 GMT 18/ 3/2020 6:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 25 14.07 521 2 7
2 12 1122.64 4 11.86 1952 2 2
3 12 1396.92 37 11.24 2350 2 2
4 7 1394.88 24 11.96 2380 2 3
5 13 1261.08 35 12.73 2188 2 5
6 13 363.40 35 13.66 896 2 12
7 8 -0.20 165 14.00 352 2 17

Cycle 127 GMT 8/ 3/2020 6:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 25 14.05 529 2 7
2 12 1119.60 4 11.91 1935 2 2
3 12 1976.92 37 10.65 3184 2 2
4 7 1972.80 24 11.47 3195 2 2
5 13 1550.64 35 12.55 2603 2 4
6 13 759.88 35 13.31 1438 2 9
7 8 0.64 165 13.97 357 2 15

Cycle 126 GMT 27/ 2/2020 5:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 24 14.04 524 2 7
2 12 1113.52 4 11.88 1953 2 2
3 12 1980.56 37 10.68 3184 2 2
4 7 1976.64 24 11.45 3192 2 2
5 13 1569.72 35 12.53 2640 2 4
6 13 616.72 35 13.41 1253 2 10
7 8 -0.44 165 13.94 359 2 21

Cycle 125 GMT 17/ 2/2020 4:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 25 14.03 542 2 7
2 12 1109.76 4 11.86 1942 2 2
3 12 1986.36 37 10.75 3180 2 2
4 7 1982.76 24 11.41 3203 2 2
5 13 1584.48 35 12.51 2663 2 4
6 13 662.28 35 13.38 1324 2 10
7 8 0.20 165 13.94 366 2 17

Cycle 124 GMT 7/ 2/2020 3:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 25 14.05 531 2 7
2 3 968.92 -1 15.27 0 2 7
3 12 1128.32 4 11.88 1954 2 2
4 12 1976.04 37 10.67 3168 2 2
5 7 1972.28 24 11.40 3182 2 2
6 13 1691.08 35 12.42 2799 2 3
7 13 587.72 35 13.44 1202 2 10
8 8 0.32 165 13.94 363 2 16

Cycle 123 GMT 28/ 1/2020 2:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 25 14.04 527 2 7
2 12 1122.16 4 11.93 1947 2 2
3 12 1973.96 37 10.76 3174 2 2
4 7 1969.76 24 11.40 3185 2 2
5 13 1540.28 35 12.55 2596 2 4
6 13 754.88 35 13.29 1429 2 9
7 8 -0.20 165 13.99 351 2 21

Cycle 122 GMT 18/ 1/2020 1:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 25 14.06 520 2 7
2 12 1114.20 4 11.97 1933 2 2
3 12 1969.92 37 10.71 3177 2 2
4 7 1965.88 24 11.39 3172 2 2
5 13 1689.44 35 12.39 2809 2 3
6 13 648.28 35 13.38 1291 2 10
7 8 0.20 165 13.93 360 2 16

Cycle 121 GMT 8/ 1/2020 0:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 26 14.06 518 2 8
2 12 1130.68 4 11.91 1961 2 2
3 12 1966.52 37 10.77 3160 2 2
4 7 1962.12 24 11.40 3169 2 2
5 13 1415.60 35 12.65 2390 2 4
6 13 543.08 35 13.48 1137 2 10
7 8 0.28 165 13.95 356 2 18

Cycle 120 GMT 28/12/2019 22:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 26 14.05 527 2 7
2 12 1036.76 4 12.02 1820 2 2
3 12 1959.04 37 10.76 3137 2 2
4 7 1955.12 24 11.35 3166 2 2
5 13 1413.92 35 12.67 2358 2 4
6 13 533.68 35 13.48 1131 2 11
7 8 0.08 165 13.94 356 2 19

Cycle 119 GMT 18/12/2019 21:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 26 14.04 542 2 7
2 12 1113.36 4 11.89 1919 2 2
3 12 1971.60 37 10.80 3181 2 2
4 7 1967.16 24 11.42 3169 2 2
5 13 1685.48 35 12.41 2799 2 3
6 13 614.12 35 13.42 1251 2 10
7 8 -0.04 165 13.97 356 2 19

Cycle 118 GMT 8/12/2019 20:34: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 26 14.04 522 2 6
2 12 1124.68 4 11.99 1950 2 2
3 12 1972.84 37 10.80 3188 2 2
4 7 1968.60 24 11.39 3182 2 2
5 13 1415.72 35 12.67 2389 2 4
6 13 676.60 35 13.36 1343 2 9
7 8 0.00 165 13.96 361 2 16

Cycle 117 GMT 28/11/2019 19:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 27 14.10 518 2 7
2 3 958.44 -1 15.30 0 2 7
3 12 1091.60 4 12.09 1913 2 2
4 12 1975.84 37 10.87 3156 2 2
5 7 1972.20 24 11.40 3177 2 2
6 13 1555.96 35 12.54 2606 2 4
7 13 653.00 35 13.39 1308 2 9
8 8 0.08 165 13.96 359 2 15

Cycle 116 GMT 18/11/2019 18:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 27 14.10 514 2 5
2 12 1099.56 4 12.05 1926 2 2
3 12 1985.52 37 10.80 3174 2 2
4 7 1981.88 24 11.36 3202 2 2
5 13 1711.04 35 12.38 2838 2 3
6 13 760.40 35 13.29 1465 2 9
7 8 0.28 165 14.01 354 2 16

Cycle 115 GMT 8/11/2019 17:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 27 14.12 520 2 3
2 3 963.52 -1 15.31 0 2 3
3 12 1122.48 4 11.97 1940 2 2
4 12 1997.00 37 10.84 3196 2 2
5 7 1993.40 24 11.42 3196 2 2
6 13 1577.28 35 12.54 2650 2 3
7 13 683.56 35 13.38 1362 2 9
8 8 -0.08 165 14.06 348 2 20

Cycle 114 GMT 29/10/2019 16: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 26 14.12 504 2 5
2 3 1028.36 1 12.42 1821 2 2
3 12 1120.32 4 12.00 1932 2 2
4 12 1992.40 37 10.82 3185 2 2
5 7 1988.44 24 11.42 3199 2 2
6 13 1710.48 35 12.40 2836 2 3
7 13 779.52 35 13.28 1498 2 9
8 13 22.40 35 14.15 387 2 12
9 8 0.04 165 14.03 344 2 17

Cycle 113 GMT 19/10/2019 15: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 27 14.14 506 2 5
2 12 1110.84 4 12.06 1919 2 2
3 12 2000.44 37 10.81 3192 2 2
4 7 1996.52 24 11.43 3213 2 2
5 13 1580.16 35 12.54 2645 2 3
6 13 682.76 35 13.40 1341 2 8
7 8 -0.32 165 14.08 338 2 24

Cycle 112 GMT 9/10/2019 14:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 27 14.12 520 2 5
2 12 1116.44 4 12.04 1929 2 2
3 12 1999.96 37 10.83 3204 2 2
4 7 1996.20 24 11.44 3212 2 2
5 13 1578.12 35 12.54 2647 2 3
6 13 681.76 35 13.41 1337 2 8
7 8 0.20 165 14.08 338 2 14

Cycle 111 GMT 29/ 9/2019 14:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 27 14.16 502 2 3
2 12 1106.88 4 12.09 1918 2 2
3 12 1999.84 37 10.85 3204 2 2
4 7 1996.04 24 11.40 3206 2 2
5 13 1574.44 35 12.54 2649 2 3
6 13 691.72 35 13.38 1367 2 9
7 8 0.28 165 14.07 340 2 18

Cycle 110 GMT 19/ 9/2019 13:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 28 14.14 524 2 3
2 3 927.76 -1 15.32 0 2 3
3 12 1077.88 4 12.02 1884 2 2
4 12 2000.28 37 10.92 3181 2 2
5 7 1996.52 24 11.47 3216 2 2
6 13 1580.20 35 12.56 2653 2 3
7 13 543.68 35 13.55 1152 2 9
8 8 -0.12 165 14.09 338 2 18

Cycle 109 GMT 9/ 9/2019 12:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 29 14.16 527 2 4
2 3 957.32 -1 15.33 0 2 4
3 12 1112.20 4 12.03 1928 2 2
4 12 1999.20 37 10.89 3184 2 2
5 7 1995.24 24 11.47 3217 2 2
6 13 1583.12 35 12.56 2640 2 3
7 13 814.80 35 13.29 1540 2 7
8 13 25.60 35 14.19 389 2 10
9 8 0.32 165 14.07 344 2 21

Cycle 108 GMT 30/ 8/2019 12: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 27 14.18 517 2 3
2 3 1072.72 2 12.78 1900 2 2
3 3 1023.00 1 12.67 1839 2 2
4 12 1127.68 4 11.81 1929 2 2
5 12 2000.00 37 10.82 3171 2 2
6 7 1996.04 25 11.47 3234 2 2
7 13 1711.00 35 12.47 2834 2 3
8 13 791.64 35 13.33 1523 2 7
9 8 -0.12 165 14.11 345 2 17

Cycle 107 GMT 20/ 8/2019 11:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 27 14.18 502 2 4
2 12 1119.44 4 11.95 1937 2 2
3 12 2001.12 37 10.85 3189 2 2
4 7 1997.44 24 11.47 3218 2 2
5 13 1715.72 35 12.43 2841 2 3
6 13 678.48 35 13.48 1340 2 7
7 8 0.04 165 14.13 337 2 16

Cycle 106 GMT 10/ 8/2019 11:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 28 14.19 501 2 4
2 3 965.16 -1 15.33 0 2 4
3 3 1018.84 1 10.89 1820 2 2
4 12 1127.48 4 11.97 1955 2 2
5 12 2002.64 37 10.91 3180 2 2
6 7 1999.04 25 11.49 3223 2 2
7 13 1575.96 35 12.56 2649 2 3
8 13 806.32 35 13.31 1536 2 8
9 8 0.12 165 14.12 339 2 15

Cycle 105 GMT 31/ 7/2019 11:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 28 14.19 507 2 3
2 12 1106.56 4 11.95 1919 2 2
3 12 2001.64 37 10.84 3185 2 2
4 7 1997.88 24 11.51 3208 2 2
5 13 1582.44 35 12.57 2658 2 3
6 13 687.60 35 13.43 1371 2 8
7 8 1.00 165 14.12 336 2 15

Cycle 104 GMT 21/ 7/2019 10:56: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 27 14.22 505 2 4
2 3 1024.88 1 11.52 1843 2 2
3 12 1127.48 4 11.95 1941 2 2
4 12 2001.00 37 10.90 3195 2 2
5 7 1997.20 24 11.52 3223 2 2
6 13 1577.40 35 12.57 2653 2 3
7 13 958.12 35 13.17 1761 2 7
8 13 14.84 35 14.24 359 2 12
9 8 -0.36 165 14.09 329 2 19

Cycle 103 GMT 11/ 7/2019 10:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 27 14.22 495 2 3
2 12 1131.36 4 11.98 1953 2 2
3 12 2000.40 37 10.95 3193 2 2
4 7 1996.64 24 11.52 3213 2 2
5 13 1585.36 35 12.57 2641 2 3
6 13 689.36 35 13.44 1359 2 9
7 13 46.80 35 14.19 416 2 11
8 8 0.24 165 14.11 336 2 18

Cycle 102 GMT 1/ 7/2019 10:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 27 14.19 503 2 3
2 12 1119.64 4 12.06 1946 2 2
3 12 1999.72 36 10.93 3206 2 2
4 7 1995.80 24 11.48 3213 2 2
5 13 1586.52 34 12.60 2650 2 4
6 13 824.20 34 13.30 1560 2 9
7 13 38.36 34 14.19 409 2 12
8 8 -0.16 165 14.09 338 2 21

Cycle 101 GMT 21/ 6/2019 9:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 14.17 514 2 4
2 3 957.32 -1 15.33 0 2 4
3 12 1132.40 4 11.99 1971 2 2
4 12 2000.64 36 11.00 3207 2 2
5 7 1996.96 24 11.50 3212 2 2
6 13 1577.76 34 12.61 2656 2 3
7 13 686.68 34 13.45 1352 2 8
8 13 32.52 34 14.21 390 2 12
9 8 0.28 165 14.11 334 2 20

Cycle 100 GMT 11/ 6/2019 9:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 27 14.23 514 2 3
2 3 1033.40 1 12.23 1847 2 2
3 12 1119.48 4 12.04 1940 2 2
4 12 2000.88 36 11.10 3183 2 2
5 7 1996.96 24 11.52 3208 2 2
6 13 1574.00 34 12.63 2640 2 4
7 13 688.32 34 13.45 1357 2 9
8 8 -0.12 165 14.12 336 2 15

Cycle 99 GMT 1/ 6/2019 9: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 14.22 510 2 3
2 3 889.68 -2 15.36 0 2 3
3 12 1111.32 4 11.72 1926 2 2
4 12 2002.48 36 10.92 3145 2 2
5 7 1998.96 24 11.53 3214 2 2
6 13 1728.20 33 12.51 2860 2 3
7 13 823.08 33 13.33 1562 2 8
8 8 0.36 165 14.15 335 2 17

Cycle 98 GMT 22/ 5/2019 8:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 29 14.22 509 2 2
2 3 1022.76 1 10.86 1819 2 2
3 12 1128.88 4 11.81 1950 2 2
4 12 2000.16 36 10.96 3167 2 2
5 7 1996.28 24 11.57 3222 2 2
6 13 1574.60 33 12.64 2638 2 3
7 13 822.68 33 13.36 1555 2 8
8 13 69.24 33 14.19 448 2 10
9 8 0.04 165 14.15 332 2 16

Cycle 97 GMT 12/ 5/2019 8:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 28 14.24 516 2 2
2 3 1020.72 1 10.99 1822 2 2
3 12 1130.40 4 11.87 1950 2 2
4 12 2001.20 36 11.04 3168 2 2
5 7 1997.36 24 11.58 3209 2 2
6 13 1727.56 33 12.52 2866 2 3
7 13 809.44 33 13.36 1545 2 8
8 8 -0.12 165 14.15 333 2 20

Cycle 96 GMT 2/ 5/2019 8: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 28 14.25 493 2 3
2 12 1112.12 4 12.01 1911 2 2
3 12 1999.36 36 10.97 3169 2 2
4 7 1995.56 24 11.56 3199 2 2
5 13 1586.36 33 12.63 2657 2 3
6 13 838.92 33 13.32 1584 2 8
7 8 0.32 165 14.15 336 2 17

Cycle 95 GMT 22/ 4/2019 8: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 29 14.25 501 2 3
2 3 965.08 -1 15.36 0 2 3
3 12 1120.36 4 11.84 1944 2 2
4 12 1999.76 36 11.03 3149 2 2
5 7 1995.88 24 11.59 3198 2 2
6 13 1454.00 33 12.77 2466 2 4
7 13 725.08 33 13.46 1417 2 8
8 8 0.16 165 14.16 331 2 20

Cycle 94 GMT 12/ 4/2019 7:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 26 14.26 501 2 2
2 3 1075.24 2 12.97 1916 2 2
3 3 1027.04 1 12.79 1856 2 2
4 12 1135.68 4 11.70 1955 2 2
5 12 2008.72 36 11.04 3152 2 2
6 7 2005.00 24 11.62 3231 2 2
7 13 1595.92 33 12.67 2664 2 3
8 13 720.88 33 13.48 1397 2 8
9 8 -0.04 165 14.17 331 2 17

Cycle 93 GMT 2/ 4/2019 7: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 14.23 511 2 2
2 3 939.48 -1 15.36 0 2 2
3 12 1108.52 4 11.82 1925 2 2
4 12 2002.60 36 11.01 3167 2 2
5 7 1999.08 24 11.59 3220 2 2
6 13 1726.80 33 12.54 2857 2 3
7 13 945.40 33 13.24 1731 2 7
8 8 0.48 165 14.16 334 2 19

Cycle 92 GMT 23/ 3/2019 6:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 14.24 491 2 3
2 3 953.68 -1 15.36 0 2 3
3 12 1127.48 4 11.61 1945 2 2
4 12 1999.48 36 11.04 3133 2 2
5 7 1995.64 24 11.63 3209 2 2
6 13 1574.72 33 12.68 2631 2 3
7 13 821.72 33 13.35 1566 2 8
8 13 37.64 33 14.25 406 2 11
9 8 -0.08 165 14.13 339 2 21
10 14 -0.08 75 14.11 337 2 27

Cycle 91 GMT 13/ 3/2019 6:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 14.27 504 2 3
2 12 1127.76 4 11.51 1939 2 2
3 12 2001.88 36 11.06 3137 2 2
4 7 1998.00 24 11.62 3209 2 2
5 13 1588.48 33 12.69 2657 2 3
6 13 832.80 33 13.37 1571 2 7
7 8 0.12 165 14.17 332 2 13

Cycle 90 GMT 3/ 3/2019 6:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 28 14.28 510 2 3
2 12 1132.28 2 8.16 1918 2 2
3 12 2004.76 36 11.03 3141 2 2
4 7 2001.72 25 11.69 3228 2 2
5 13 1589.56 33 12.69 2676 2 3
6 13 851.20 33 13.35 1608 2 7
7 8 0.36 165 14.17 336 2 14

Cycle 89 GMT 21/ 2/2019 7: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 29 14.27 497 2 3
2 3 948.88 -1 15.37 0 2 3
3 12 1121.12 2 7.90 1887 2 2
4 12 2001.52 36 11.05 3132 2 2
5 7 1998.08 24 11.68 3218 2 2
6 13 1593.20 33 12.70 2658 2 3
7 13 850.80 33 13.35 1596 2 7
8 8 0.12 165 14.16 333 2 16

Cycle 88 GMT 11/ 2/2019 7:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 28 14.26 495 2 2
2 3 1057.60 1 13.04 1885 2 2
3 3 1027.00 1 12.95 1847 2 2
4 12 2004.04 36 10.81 3074 2 2
5 7 2000.80 24 11.67 3224 2 2
6 13 1734.12 33 12.58 2868 2 3
7 13 972.32 33 13.23 1784 2 7
8 13 32.40 33 14.26 387 2 11
9 8 0.08 165 14.17 327 2 18

Cycle 87 GMT 1/ 2/2019 7:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 28 14.27 492 2 3
2 12 2002.88 36 10.73 3079 2 2
3 7 1999.72 24 11.68 3220 2 2
4 13 1599.44 33 12.69 2677 2 3
5 13 857.96 33 13.35 1612 2 8
6 8 -0.12 165 14.17 328 2 18

Cycle 86 GMT 22/ 1/2019 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 28 14.27 494 2 3
2 3 964.24 -1 15.37 0 2 3
3 12 2003.72 36 10.75 3066 2 2
4 7 2000.60 24 11.70 3220 2 2
5 13 1598.20 33 12.71 2670 2 3
6 13 878.36 33 13.34 1651 2 7
7 8 0.20 165 14.15 349 2 14

Cycle 85 GMT 12/ 1/2019 8:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 29 14.28 494 2 2
2 3 966.28 -1 15.37 0 2 2
3 3 1022.68 1 11.14 1823 2 2
4 12 2003.28 32 10.64 3038 2 2
5 7 2000.40 24 11.75 3227 2 2
6 13 1740.96 35 12.52 2879 2 3
7 13 977.52 35 13.22 1789 2 8
8 13 13.12 35 14.29 365 2 10
9 8 0.08 165 14.12 332 2 13

Cycle 84 GMT 2/ 1/2019 8:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 14.30 489 2 3
2 3 1023.92 1 11.86 1826 2 2
3 12 2002.92 32 10.65 3023 2 2
4 7 2000.00 24 11.79 3230 2 2
5 13 1739.16 35 12.54 2882 2 3
6 13 858.72 35 13.34 1627 2 7
7 8 0.12 165 14.17 334 2 15

Cycle 83 GMT 23/12/2018 9: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 28 14.30 486 2 3
2 3 971.40 -1 15.37 0 2 3
3 3 1027.04 1 12.15 1833 2 2
4 12 2006.44 32 10.65 3046 2 2
5 7 2003.52 24 11.73 3222 2 2
6 13 1735.68 35 12.52 2873 2 3
7 13 859.96 35 13.35 1609 2 7
8 8 -0.16 165 14.18 328 2 19

Cycle 82 GMT 13/12/2018 9:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 29 14.32 495 2 3
2 3 951.20 -1 15.38 0 2 3
3 7 2001.80 45 10.60 3136 2 2
4 13 1878.92 39 12.28 3056 2 2
5 13 1138.24 39 13.05 2018 2 6
6 8 0.20 165 14.19 328 2 15

Cycle 81 GMT 3/12/2018 9:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 14.31 489 2 3
2 3 1028.84 1 12.46 1841 2 2
3 7 2002.52 44 10.52 3139 2 2
4 13 1889.04 39 12.31 3079 2 2
5 13 1153.32 39 13.05 2041 2 6
6 13 19.20 39 14.31 363 2 9
7 8 0.00 165 14.13 328 2 20

Cycle 80 GMT 23/11/2018 10: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 14.32 495 2 3
2 3 973.48 -1 15.38 0 2 3
3 3 1029.16 1 12.24 1834 2 2
4 7 2003.28 44 10.57 3120 2 2
5 13 1879.36 39 12.31 3060 2 2
6 13 1139.88 39 13.08 2013 2 6
7 8 0.04 165 14.20 324 2 16

Cycle 79 GMT 13/11/2018 10:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 14.33 513 2 3
2 3 972.32 -1 15.38 0 2 3
3 3 1029.76 1 12.25 1831 2 2
4 7 2008.24 44 10.54 3131 2 2
5 13 1891.28 39 12.32 3078 2 2
6 13 1140.88 39 13.07 2022 2 6
7 13 39.44 39 14.29 392 2 10
8 8 0.32 165 14.17 330 2 18

Cycle 78 GMT 3/11/2018 10:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 27 14.29 514 2 3
2 3 1030.08 1 12.51 1852 2 2
3 3 1020.64 1 12.59 1854 2 2
4 7 2003.88 44 10.55 3137 2 2
5 13 1885.52 39 12.35 3071 2 2
6 13 1161.32 39 13.07 2047 2 6
7 13 19.32 39 14.30 380 2 9
8 8 -0.16 165 14.10 344 2 22

Cycle 77 GMT 24/10/2018 11:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 27 14.33 480 2 3
2 7 2003.16 44 10.51 3118 2 2
3 13 1888.88 39 12.34 3084 2 2
4 13 1036.64 39 13.17 1881 2 7
5 13 22.80 39 14.29 387 2 11
6 8 0.00 165 14.15 344 2 18

Cycle 76 GMT 14/10/2018 11:34: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 28 14.30 500 2 3
2 3 944.92 -1 15.39 0 2 3
3 7 2007.00 44 10.53 3121 3 2
4 13 1898.52 39 12.34 3097 2 2
5 13 1170.36 39 13.06 2069 2 7
6 8 -0.12 165 14.21 325 2 18

Cycle 75 GMT 4/10/2018 11:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 14.32 507 2 3
2 7 2003.32 44 10.56 3149 2 2
3 13 1883.92 39 12.36 3086 2 2
4 13 1142.24 39 13.10 2031 2 6
5 8 0.24 165 14.18 332 2 20

Cycle 74 GMT 24/ 9/2018 12: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 28 14.31 511 2 4
2 7 2002.24 44 10.65 3151 4 2
3 13 1880.40 39 12.38 3067 2 2
4 13 1138.44 39 13.12 2019 2 7
5 8 0.04 165 14.20 331 2 18

Cycle 73 GMT 14/ 9/2018 12:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 28 14.34 511 2 3
2 7 2003.80 44 10.72 3179 2 2
3 13 1882.56 39 12.38 3078 2 2
4 13 1013.00 39 13.23 1838 2 7
5 13 35.40 39 14.30 400 2 12
6 8 0.36 165 14.16 333 2 16

Cycle 72 GMT 4/ 9/2018 12:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 28 14.33 513 2 3
2 7 2004.92 45 10.67 3161 3 2
3 13 1882.80 39 12.39 3073 2 2
4 13 1139.84 39 13.12 2019 2 7
5 13 143.92 39 14.18 558 2 11
6 8 -0.20 165 14.20 324 2 22

Cycle 71 GMT 25/ 8/2018 12:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 26 14.38 487 2 3
2 3 1067.56 2 13.51 1921 2 3
3 3 1024.64 1 13.16 1857 2 2
4 7 2002.28 44 10.89 3168 2 2
5 13 1883.68 39 12.41 3069 2 3
6 13 1137.96 39 13.13 2032 2 7
7 13 63.12 39 14.26 442 2 11
8 8 0.16 165 14.16 335 2 19

Cycle 70 GMT 15/ 8/2018 13:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 27 14.33 510 2 3
2 3 966.40 -1 15.39 0 2 3
3 3 1019.44 1 11.82 1839 2 2
4 7 2004.96 44 10.89 3172 2 2
5 13 1878.00 39 12.43 3058 2 3
6 13 1122.80 39 13.15 1999 2 7
7 13 25.24 39 14.33 373 2 11
8 8 0.08 165 14.18 323 2 19

Cycle 69 GMT 5/ 8/2018 13:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 27 14.35 491 2 3
2 7 2003.00 44 10.97 3183 3 2
3 13 1881.00 39 12.43 3075 2 2
4 13 1116.44 39 13.17 1991 2 7
5 13 34.72 39 14.32 390 2 12
6 8 0.16 165 14.17 328 2 19

Cycle 68 GMT 26/ 7/2018 13:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 26 14.37 486 2 4
2 3 1020.80 1 11.93 1832 2 2
3 7 2005.08 44 11.04 3212 2 2
4 13 1879.24 39 12.45 3073 2 3
5 13 987.64 39 13.30 1806 2 8
6 8 0.24 165 14.19 333 2 13

Cycle 67 GMT 16/ 7/2018 14: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 28 14.36 484 2 3
2 3 948.28 -1 15.39 0 2 3
3 7 2002.76 44 11.08 3204 2 2
4 13 1880.00 39 12.47 3070 2 3
5 13 991.40 39 13.31 1799 2 8
6 13 33.08 39 14.32 388 2 12
7 8 -0.28 165 14.17 329 2 19

Cycle 66 GMT 6/ 7/2018 14:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 27 14.38 513 2 3
2 7 2003.24 44 11.12 3229 2 2
3 13 1882.08 39 12.48 3061 2 3
4 13 995.32 39 13.32 1812 2 8
5 13 19.24 39 14.34 368 2 12
6 8 0.20 165 14.17 328 2 17

Cycle 65 GMT 26/ 6/2018 14:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 14.36 490 2 2
2 7 2001.20 44 11.17 3204 2 2
3 13 1870.96 39 12.49 3052 2 3
4 13 986.16 39 13.33 1799 2 8
5 8 -0.04 165 14.19 335 2 19

Cycle 64 GMT 16/ 6/2018 15: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 28 14.37 480 2 3
2 3 946.32 -1 15.39 0 2 3
3 7 2005.80 44 11.25 3226 2 2
4 13 1880.88 39 12.50 3068 2 3
5 13 989.92 39 13.34 1816 2 8
6 8 0.60 165 14.19 330 2 18

Cycle 63 GMT 6/ 6/2018 15:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 14.38 490 2 2
2 7 2003.60 45 11.43 3224 2 2
3 13 1877.88 39 12.53 3066 2 3
4 13 969.08 39 13.35 1795 2 8
5 8 -0.08 165 14.21 329 2 16

Cycle 62 GMT 27/ 5/2018 15:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 28 14.38 477 2 3
2 3 964.04 -1 15.39 0 2 3
3 3 1023.60 1 12.92 1864 2 2
4 7 2003.04 47 11.46 3212 2 2
5 13 1871.88 24 12.80 3065 2 3
6 13 1300.24 24 13.30 2237 2 5
7 13 574.56 24 13.87 1192 2 8
8 8 -0.08 165 14.22 323 2 19

Cycle 61 GMT 17/ 5/2018 15:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 28 14.37 488 2 3
2 7 2005.28 46 11.54 3217 2 2
3 13 1875.36 24 12.82 3069 2 3
4 13 1294.92 24 13.30 2255 2 6
5 13 566.68 24 13.87 1201 2 8
6 8 0.36 165 14.19 327 2 20

Cycle 60 GMT 7/ 5/2018 15:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 28 14.40 480 2 3
2 3 953.96 -1 15.38 0 2 3
3 7 2001.48 46 11.63 3212 2 2
4 13 1871.68 24 12.83 3077 2 3
5 13 1298.28 24 13.31 2259 2 6
6 13 572.76 24 13.87 1200 2 8
7 13 24.52 24 14.33 375 2 10
8 8 -0.08 165 14.18 324 2 17

Cycle 59 GMT 27/ 4/2018 16: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 27 14.41 498 2 2
2 3 1038.80 1 13.69 1895 2 2
3 7 2003.56 47 11.71 3213 2 2
4 13 1870.28 24 12.86 3072 2 3
5 13 1156.04 24 13.42 2054 2 7
6 13 580.44 24 13.86 1214 2 9
7 8 0.32 165 14.20 325 2 15

Cycle 58 GMT 17/ 4/2018 16:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 29 14.39 479 2 3
2 3 942.00 -1 15.38 0 2 3
3 7 2003.40 46 11.77 3215 3 2
4 13 1871.96 24 12.86 3069 2 3
5 13 1162.00 24 13.43 2066 2 7
6 13 588.16 24 13.86 1232 2 9
7 8 -0.04 165 14.20 326 2 23

Cycle 57 GMT 7/ 4/2018 16:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 28 14.38 502 2 2
2 3 1021.20 1 12.99 1898 2 2
3 7 2004.32 47 11.83 3224 2 2
4 13 1870.12 24 12.88 3070 2 3
5 13 1277.64 24 13.37 2215 2 6
6 13 414.12 24 14.02 964 2 8
7 8 0.20 165 14.21 329 2 15

Cycle 56 GMT 28/ 3/2018 16: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 28 14.35 496 2 2
2 3 967.24 -1 15.37 0 2 2
3 3 1020.76 1 12.87 1882 2 2
4 7 2001.08 46 11.95 3219 2 2
5 13 1866.72 24 12.90 3063 2 3
6 13 1275.76 24 13.38 2213 2 6
7 13 543.24 24 13.93 1151 2 8
8 8 -0.12 165 14.21 327 2 14

Cycle 55 GMT 18/ 3/2018 16:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 14.42 497 2 2
2 7 2002.44 46 11.98 3221 2 2
3 13 1739.68 24 13.06 2893 2 3
4 13 1193.00 24 13.45 2109 2 6
5 13 468.68 24 13.98 1048 2 8
6 8 0.04 165 14.22 328 2 16

Cycle 54 GMT 8/ 3/2018 16:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 27 14.45 488 2 2
2 3 1055.52 1 13.95 1913 2 2
3 3 1020.96 1 13.35 1866 2 2
4 7 2006.64 47 12.08 3223 2 2
5 13 1620.40 24 13.17 2699 2 4
6 13 1080.96 24 13.53 1943 2 7
7 13 241.04 24 14.18 700 2 8
8 8 0.24 165 14.22 325 2 19

Cycle 53 GMT 26/ 2/2018 15:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 27 14.42 483 2 2
2 7 2001.68 46 12.14 3220 2 2
3 13 1745.32 24 13.11 2890 2 3
4 13 1175.44 24 13.48 2079 2 6
5 13 449.64 24 14.03 1006 2 8
6 8 -0.08 165 14.23 324 2 16

Cycle 52 GMT 16/ 2/2018 16: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 27 14.45 477 2 2
2 3 1018.88 1 13.41 1867 2 2
3 7 2004.56 46 12.28 3226 2 2
4 13 1745.64 24 13.14 2885 2 3
5 13 1309.76 24 13.40 2285 2 6
6 13 430.68 24 14.05 985 2 8
7 8 0.16 165 14.24 329 2 17

Cycle 51 GMT 6/ 2/2018 16: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 27 14.41 487 2 2
2 7 2005.32 46 12.36 3230 2 2
3 13 1870.08 24 13.01 3067 2 3
4 13 1424.68 24 13.34 2457 2 5
5 13 508.88 24 13.99 1120 2 8
6 8 0.08 165 14.22 334 2 16

Cycle 50 GMT 27/ 1/2018 16:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 14.43 501 2 2
2 7 2003.68 47 12.47 3231 2 2
3 13 1730.64 24 13.18 2858 2 3
4 13 1029.88 24 13.60 1884 2 7
5 13 438.48 24 14.05 996 2 8
6 8 -0.04 165 14.24 325 2 18

Cycle 49 GMT 17/ 1/2018 16:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 14.41 507 2 2
2 3 969.72 -1 15.36 0 2 2
3 7 2007.96 46 12.55 3237 2 2
4 13 1618.00 24 13.24 2707 2 4
5 13 1072.04 24 13.57 1922 2 7
6 13 348.08 24 14.12 859 2 8
7 8 -0.04 165 14.24 333 2 15

Cycle 48 GMT 7/ 1/2018 16:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 27 14.45 488 2 2
2 7 2005.20 47 12.54 3221 2 2
3 13 1732.80 24 13.18 2876 2 3
4 13 1026.68 24 13.59 1871 2 7
5 13 442.52 24 14.05 999 2 8
6 13 22.20 24 14.38 381 2 11
7 8 0.08 165 14.21 331 2 18

Cycle 47 GMT 28/12/2017 16:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 27 14.44 493 2 2
2 7 2003.44 47 12.59 3233 2 2
3 13 1735.96 24 13.19 2866 2 3
4 13 1023.84 24 13.61 1866 2 7
5 13 291.68 24 14.16 790 2 8
6 8 0.24 165 14.25 331 2 15
7 14 0.24 75 14.21 324 2 24

Cycle 46 GMT 18/12/2017 16:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 27 14.44 498 2 2
2 7 2005.64 46 12.65 3248 2 2
3 13 1606.44 24 13.27 2701 2 4
4 13 1181.36 24 13.50 2112 2 6
5 13 295.52 24 14.17 796 2 8
6 8 0.04 165 14.24 330 2 17

Cycle 45 GMT 8/12/2017 16:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 27 14.48 502 2 2
2 7 2001.32 47 12.68 3227 2 2
3 13 1729.76 24 13.22 2864 2 3
4 13 1021.16 24 13.62 1856 2 7
5 13 289.04 24 14.18 783 2 8
6 8 0.16 165 14.25 330 2 15

Cycle 44 GMT 28/11/2017 16:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 27 14.46 505 2 3
2 7 2004.44 46 12.74 3232 2 2
3 13 1609.48 24 13.29 2676 2 4
4 13 1038.96 24 13.62 1892 2 7
5 13 171.36 24 14.28 607 2 8
6 8 -0.04 165 14.27 326 2 20

Cycle 43 GMT 18/11/2017 16:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 26 14.50 506 2 3
2 3 1041.20 1 14.21 1893 2 2
3 7 2003.76 46 12.77 3243 2 2
4 13 1731.68 24 13.24 2870 2 3
5 13 1025.08 24 13.64 1863 2 7
6 13 448.08 24 14.08 1015 2 8
7 8 -0.12 165 14.26 331 2 19

Cycle 42 GMT 8/11/2017 16:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 26 14.49 498 2 4
2 3 970.08 -1 15.34 0 2 4
3 3 1022.80 1 13.70 1866 2 2
4 7 2005.72 46 12.80 3239 2 2
5 13 1606.80 24 13.32 2700 2 4
6 13 1046.04 24 13.64 1898 2 7
7 13 309.04 24 14.20 809 2 8
8 8 0.16 165 14.27 331 2 18

Cycle 41 GMT 29/10/2017 16:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 25 14.51 501 2 3
2 3 1041.80 1 14.26 1888 2 2
3 7 2001.88 43 12.87 3236 2 2
4 13 1738.12 24 13.27 2890 2 4
5 13 1152.00 24 13.58 2055 2 6
6 13 406.80 24 14.14 948 2 8
7 13 24.16 24 14.44 382 2 10
8 8 -0.12 150 14.27 330 2 18

Cycle 40 GMT 19/10/2017 16: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 27 14.47 499 2 3
2 3 925.08 -1 15.35 0 2 3
3 7 2002.04 43 12.91 3224 3 2
4 13 1732.88 24 13.30 2870 2 4
5 13 1288.68 24 13.54 2234 2 5
6 13 382.52 24 14.15 932 2 8
7 13 13.36 24 14.46 368 2 10
8 8 0.24 150 14.26 333 2 15

Cycle 39 GMT 9/10/2017 16:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 26 14.52 514 2 2
2 3 1032.88 1 14.27 1878 2 2
3 7 2002.92 43 12.91 3232 2 2
4 13 1743.80 24 13.29 2900 2 3
5 13 1168.88 24 13.61 2067 2 7
6 13 284.88 24 14.25 772 2 8
7 8 -0.20 150 14.31 332 2 17

Cycle 38 GMT 29/ 9/2017 16:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 26 14.51 505 2 2
2 7 2003.52 43 12.96 3237 2 2
3 13 1737.36 24 13.32 2879 2 3
4 13 1166.04 24 13.62 2076 2 7
5 13 294.48 24 14.26 784 2 8
6 8 0.32 150 14.33 332 2 16

Cycle 37 GMT 19/ 9/2017 16:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 26 14.54 488 2 3
2 7 2004.28 43 12.97 3242 3 2
3 13 1868.20 24 13.22 3063 2 3
4 13 1136.36 24 13.65 2032 2 7
5 13 266.16 24 14.28 757 2 8
6 8 -0.08 150 14.34 331 2 11

Cycle 36 GMT 9/ 9/2017 16: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 28 14.54 492 2 2
2 3 942.00 -1 15.37 0 2 2
3 7 2001.68 43 12.98 3234 2 2
4 13 1731.76 24 13.35 2877 2 4
5 13 1153.36 24 13.66 2057 2 7
6 13 410.60 24 14.19 970 2 8
7 13 16.56 24 14.51 376 2 11
8 8 0.08 150 14.31 335 2 17

Cycle 35 GMT 30/ 8/2017 16: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 24 14.56 512 2 3
2 10 1008.96 3 14.50 1865 2 3
3 3 1032.40 1 14.35 1920 2 2
4 7 2004.36 43 12.98 3237 2 2
5 13 1868.44 24 13.24 3066 2 3
6 13 1134.08 24 13.67 2031 2 7
7 13 393.40 24 14.21 945 2 9
8 8 -0.04 150 14.34 334 2 15

Cycle 34 GMT 20/ 8/2017 16:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 26 14.51 498 2 3
2 3 913.00 -2 15.39 0 2 3
3 7 2002.96 43 13.00 3237 2 2
4 13 1737.40 24 13.36 2870 2 3
5 13 1150.76 24 13.68 2042 2 6
6 13 273.64 24 14.32 758 2 8
7 8 0.12 150 14.36 332 2 12

Cycle 33 GMT 10/ 8/2017 16:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 26 14.54 505 2 3
2 7 2004.52 43 13.00 3244 2 2
3 13 1871.44 24 13.25 3061 2 3
4 13 1008.80 24 13.76 1857 2 7
5 13 290.16 24 14.31 798 2 8
6 8 0.04 150 14.35 333 2 11
7 14 0.04 90 14.30 328 2 23

Cycle 32 GMT 31/ 7/2017 16: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 26 14.55 503 2 3
2 7 2003.16 43 13.01 3237 2 2
3 13 1729.76 24 13.37 2879 2 4
4 13 1151.04 24 13.69 2034 2 6
5 13 411.88 24 14.23 959 2 9
6 8 0.08 150 14.36 334 2 14

Cycle 31 GMT 21/ 7/2017 16: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 26 14.55 495 2 3
2 7 2001.24 43 13.02 3233 3 2
3 13 1726.52 24 13.36 2861 2 3
4 13 1148.32 24 13.68 2058 2 7
5 13 268.52 24 14.35 752 2 9
6 8 0.12 150 14.37 331 2 14

Cycle 30 GMT 11/ 7/2017 15:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 26 14.53 495 2 3
2 7 2003.56 43 13.00 3243 2 2
3 13 1614.56 24 13.41 2692 2 4
4 13 1066.96 24 13.74 1935 2 7
5 13 331.52 24 14.30 857 2 9
6 8 -0.04 150 14.36 340 2 16

Cycle 29 GMT 1/ 7/2017 15:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 26 14.56 489 2 3
2 7 2002.96 43 13.00 3244 2 2
3 13 1739.00 24 13.36 2880 2 3
4 13 1041.08 24 13.75 1912 2 8
5 13 318.20 24 14.32 834 2 9
6 8 0.00 150 14.38 330 2 15

Cycle 28 GMT 21/ 6/2017 15:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 27 14.53 500 2 3
2 3 950.04 -1 15.44 0 2 3
3 7 2001.84 43 13.02 3242 3 2
4 13 1730.64 24 13.36 2869 2 4
5 13 1155.12 24 13.69 2067 2 7
6 13 405.36 24 14.24 967 2 9
7 8 0.24 150 14.37 337 2 18

Cycle 27 GMT 11/ 6/2017 15:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 26 14.57 495 2 3
2 3 1025.76 1 14.40 1894 2 2
3 7 2003.48 43 13.02 3233 2 2
4 13 1611.92 24 13.42 2695 2 4
5 13 1056.36 24 13.75 1932 2 8
6 13 198.52 24 14.42 666 2 9
7 8 0.24 150 14.37 342 2 19

Cycle 26 GMT 1/ 6/2017 14:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 26 14.55 498 2 3
2 7 2002.12 43 13.02 3231 2 2
3 13 1731.36 24 13.34 2893 2 4
4 13 1021.68 24 13.77 1874 2 8
5 13 293.76 24 14.35 801 2 9
6 8 0.24 150 14.36 338 2 14

Cycle 25 GMT 22/ 5/2017 14:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 27 14.54 489 2 3
2 3 960.76 -1 15.46 0 2 3
3 7 2001.60 43 13.01 3245 2 2
4 13 1729.76 24 13.35 2868 2 4
5 13 1149.68 24 13.70 2061 2 7
6 13 268.16 24 14.37 768 2 9
7 8 -0.08 150 14.38 337 2 13

Cycle 24 GMT 12/ 5/2017 14:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 26 14.58 503 2 3
2 3 1029.12 1 14.48 1912 2 2
3 7 2001.92 43 13.02 3228 2 2
4 13 1732.08 24 13.35 2876 2 3
5 13 1151.20 24 13.70 2054 2 7
6 13 409.56 24 14.26 981 2 9
7 8 0.08 150 14.36 348 2 16

Cycle 23 GMT 2/ 5/2017 14:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 26 14.59 480 2 2
2 3 1029.08 1 14.47 1908 2 2
3 7 2002.80 43 13.02 3246 2 2
4 13 1728.76 24 13.35 2875 2 4
5 13 1155.56 24 13.70 2058 2 7
6 13 413.04 24 14.27 972 2 9
7 8 -0.04 150 14.38 335 2 15

Cycle 22 GMT 22/ 4/2017 14:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 26 14.55 508 2 2
2 7 2002.88 43 13.03 3229 2 2
3 13 1721.96 23 13.38 2837 2 4
4 13 1143.04 23 13.73 2009 2 6
5 13 412.84 23 14.27 972 2 9
6 8 0.32 150 14.40 333 2 14

Cycle 21 GMT 12/ 4/2017 14: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 27 14.56 511 2 2
2 3 961.68 -1 15.49 0 2 2
3 7 2002.72 43 13.03 3255 2 2
4 13 1609.24 23 13.43 2691 2 4
5 13 1060.16 23 13.77 1939 2 8
6 13 325.44 23 14.34 860 2 9
7 13 14.32 23 14.59 386 2 11
8 8 -0.08 150 14.32 342 2 14

Cycle 20 GMT 2/ 4/2017 13:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 27 14.58 510 2 2
2 7 2003.84 42 13.03 3246 2 2
3 13 1512.60 22 13.51 2563 2 4
4 13 995.20 22 13.84 1847 2 7
5 13 207.64 22 14.46 682 2 8
6 8 0.28 150 14.37 340 2 12

Cycle 19 GMT 23/ 3/2017 12:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 27 14.58 516 2 2
2 7 2003.84 42 13.05 3264 2 2
3 13 1616.44 22 13.48 2707 2 4
4 13 969.24 22 13.87 1796 2 8
5 13 175.40 22 14.48 630 2 9
6 8 0.28 150 14.37 340 2 15

Cycle 18 GMT 13/ 3/2017 12: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 27 14.60 498 2 3
2 7 2002.00 42 13.08 3235 2 2
3 13 1498.16 22 13.54 2555 2 5
4 13 1104.16 22 13.80 1989 2 8
5 13 159.64 22 14.50 613 2 8
6 8 0.08 150 14.39 339 2 12

Cycle 17 GMT 3/ 3/2017 11:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 27 14.59 511 2 3
2 7 2003.08 42 13.06 3241 2 2
3 13 1621.64 22 13.49 2719 2 4
4 13 1075.24 22 13.82 1954 2 8
5 13 245.60 22 14.45 724 2 9
6 8 0.24 150 14.40 331 2 18

Cycle 16 GMT 21/ 2/2017 10:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 27 14.63 500 2 3
2 7 2002.12 42 13.09 3248 2 2
3 13 1611.32 22 13.50 2720 2 4
4 13 961.76 22 13.88 1803 2 8
5 13 150.00 22 14.51 599 2 9
6 8 -0.16 150 14.40 338 2 15

Cycle 15 GMT 11/ 2/2017 10: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 14.62 489 2 3
2 7 2002.00 43 13.07 3253 3 2
3 13 1497.40 22 13.57 2537 2 5
4 13 976.12 22 13.89 1811 2 8
5 13 160.04 22 14.52 596 2 9
6 8 0.20 150 14.39 338 2 16

Cycle 14 GMT 1/ 2/2017 9:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 27 14.60 513 2 2
2 3 1019.72 1 14.53 1894 2 2
3 7 2003.44 42 13.10 3266 2 2
4 13 1622.48 22 13.51 2714 2 4
5 13 1078.12 22 13.82 1957 2 8
6 13 257.36 22 14.45 730 2 9
7 8 0.28 150 14.42 332 2 19

Cycle 13 GMT 22/ 1/2017 8:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 26 14.62 478 2 3
2 7 2002.12 43 13.08 3240 2 2
3 13 1492.56 20 13.60 2558 2 5
4 13 982.92 20 13.91 1833 2 8
5 13 323.76 20 14.39 858 2 8
6 8 0.12 150 14.39 349 2 19

Cycle 12 GMT 12/ 1/2017 7:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 26 14.70 474 2 2
2 7 2001.76 42 13.12 3205 2 3
3 13 1612.48 20 13.57 2679 2 5
4 13 1079.04 20 13.86 1928 2 9
5 13 283.08 20 14.45 755 2 8
6 13 12.68 20 14.70 344 2 10
7 8 -0.28 150 14.39 314 2 21

Cycle 11 GMT 2/ 1/2017 6:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 26 14.63 511 2 3
2 7 2001.36 42 13.09 3241 2 3
3 13 1503.76 20 13.59 2582 2 6
4 13 990.00 20 13.91 1807 2 8
5 13 209.68 20 14.52 633 2 8
6 8 0.08 240 14.35 312 2 22

Cycle 10 GMT 23/12/2016 5:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 26 14.65 507 2 3
2 7 2002.40 42 13.11 3221 3 3
3 13 1608.32 20 13.56 2689 2 5
4 13 965.00 20 13.93 1768 2 9
5 13 429.76 20 14.31 1009 2 8
6 8 -0.04 240 14.31 348 2 22

Cycle 9 GMT 13/12/2016 4:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 26 14.64 512 2 3
2 7 2001.40 42 13.10 3201 2 3
3 13 1592.64 20 13.56 2688 2 5
4 13 1057.64 20 13.86 1902 2 9
5 13 262.72 20 14.46 752 2 9
6 8 0.12 240 14.33 338 2 23

Cycle 8 GMT 3/12/2016 3:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 26 14.64 500 2 2
2 7 2001.16 42 13.10 3239 2 3
3 13 1498.28 26 13.46 2544 2 5
4 13 835.24 26 13.88 1608 2 8
5 13 25.00 26 14.66 386 2 9
6 8 -0.20 240 14.28 334 2 24

Cycle 7 GMT 23/11/2016 2:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 25 14.66 479 2 3
2 3 1047.36 1 14.59 1887 2 2
3 7 2000.92 49 13.00 3224 2 3
4 13 1461.64 25 13.52 2503 2 5
5 13 656.36 25 14.08 1299 2 9
6 13 19.32 25 14.69 368 2 10
7 8 0.16 240 14.30 320 2 20

Cycle 6 GMT 13/11/2016 1:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 25 14.64 466 2 3
2 7 2004.44 49 12.97 3195 3 3
3 13 1338.24 25 13.55 2308 2 6
4 13 670.00 25 14.04 1311 2 9
5 8 0.12 240 14.33 308 2 24

Cycle 5 GMT 3/11/2016 0:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 24 14.62 475 2 4
2 3 1041.88 1 14.56 1863 2 2
3 7 2002.48 74 12.77 3173 2 3
4 13 926.52 25 13.81 1688 2 8
5 8 0.08 240 14.35 303 2 19

Cycle 4 GMT 23/10/2016 23:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 26 14.62 465 2 3
2 7 1510.72 74 13.10 2496 3 3
3 13 502.36 25 14.17 1051 2 8
4 8 0.08 240 14.32 299 2 23

Cycle 3 GMT 23/10/2016 0: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 26 14.53 468 2 2
2 7 1505.80 74 12.99 2485 2 3
3 13 511.64 25 14.11 1060 2 7
4 8 0.00 240 14.31 292 2 22

Cycle 2 GMT 22/10/2016 0:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 24 14.52 462 2 3
2 3 1049.36 1 14.25 1868 2 2
3 7 1514.72 74 12.79 2491 2 3
4 13 528.68 25 14.01 1081 2 7
5 8 0.12 240 14.26 291 2 24

Cycle 1 GMT 21/10/2016 1:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 24 14.36 456 2 4
2 3 1049.00 1 13.80 1847 2 2
3 3 1030.28 1 13.83 1827 2 2
4 7 1014.04 74 12.97 1758 2 5
5 8 0.36 240 14.20 288 2 23

Cycle 0 GMT 20/10/2016 14: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.44 24 14.21 416 2 6
2 7 78.40 74 14.01 417 6 10
3 8 0.28 240 14.06 286 2 30