SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8529 WMO= 5902518


Cycle 300 GMT 15/12/2024 3:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 21 14.85 753 2 2
2 7 2002.88 53 13.96 3655 2 2
3 13 1726.96 37 13.92 3224 2 2
4 13 686.12 37 14.47 1805 2 2
5 13 111.96 37 14.79 957 2 2
6 8 0.08 150 14.81 653 2 3

Cycle 299 GMT 5/12/2024 3:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 22 14.87 748 2 2
2 7 2005.16 53 13.96 3649 2 2
3 13 1751.48 37 13.88 3384 2 2
4 13 1004.84 37 14.26 2207 2 2
5 13 117.04 37 14.80 937 2 2
6 13 26.36 37 14.84 738 2 2
7 8 -0.12 150 14.78 643 2 7

Cycle 298 GMT 25/11/2024 3:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 22 14.88 719 2 2
2 7 2005.04 54 13.96 3639 2 2
3 13 1467.88 37 14.03 2939 2 2
4 13 579.28 37 14.47 1728 2 2
5 13 79.40 37 14.82 859 2 2
6 8 -0.04 150 14.80 645 2 4

Cycle 297 GMT 15/11/2024 3:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 22 14.87 750 2 2
2 7 2003.60 53 13.95 3670 2 2
3 13 1752.56 37 13.92 3220 2 2
4 13 814.80 37 14.39 2012 2 2
5 13 104.32 37 14.82 912 2 2
6 8 0.12 150 14.83 635 2 4

Cycle 296 GMT 5/11/2024 4:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 22 14.87 729 2 2
2 7 2004.88 53 13.99 3588 2 2
3 13 1476.96 37 13.99 3000 2 2
4 13 656.52 37 14.43 1826 2 2
5 13 115.52 37 14.80 936 2 2
6 8 0.12 150 14.83 631 2 3

Cycle 295 GMT 26/10/2024 3:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 22 14.89 735 2 2
2 7 2003.00 54 13.97 3626 2 2
3 13 1735.48 37 13.91 3296 2 2
4 13 706.04 37 14.41 1897 2 2
5 13 112.96 37 14.80 947 2 2
6 8 0.08 150 14.82 632 2 4

Cycle 294 GMT 16/10/2024 3:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 21 14.90 756 2 2
2 7 2002.32 53 13.98 3625 2 2
3 13 1733.28 37 13.89 3288 2 2
4 13 834.84 37 14.33 2096 2 2
5 13 115.52 37 14.81 941 2 2
6 8 0.08 150 14.83 634 2 3

Cycle 293 GMT 6/10/2024 4: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 22 14.86 725 2 2
2 3 969.24 -1 15.36 1 2 2
3 7 2002.80 54 13.99 3596 2 2
4 13 1742.44 37 13.87 3253 2 2
5 13 840.88 37 14.38 2074 2 2
6 13 112.44 37 14.82 939 2 2
7 8 0.12 150 14.84 633 2 2

Cycle 292 GMT 26/ 9/2024 4:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 21 14.89 762 2 2
2 3 1046.28 1 14.71 2515 2 2
3 3 1019.00 1 15.23 1884 2 2
4 7 2004.28 53 13.95 3727 2 2
5 13 1466.36 37 14.01 2878 2 2
6 13 884.48 37 14.29 2176 2 2
7 13 129.84 37 14.79 961 2 2
8 13 15.60 37 14.87 692 2 2
9 8 0.00 150 14.79 637 2 5

Cycle 291 GMT 16/ 9/2024 4:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 22 14.88 728 2 2
2 3 960.16 -1 15.38 1 2 2
3 7 2003.28 53 13.97 3659 2 2
4 13 1870.28 37 13.81 3456 2 2
5 13 912.48 37 14.27 2225 2 2
6 13 130.36 37 14.80 984 2 2
7 8 -0.04 150 14.84 640 2 3

Cycle 290 GMT 6/ 9/2024 4:56: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 22 14.85 760 2 2
2 7 2004.88 53 13.97 3600 2 2
3 13 1870.68 37 13.84 3478 2 2
4 13 653.56 37 14.46 1837 2 2
5 13 109.52 37 14.83 901 2 2
6 8 -0.04 150 14.85 638 2 2

Cycle 289 GMT 27/ 8/2024 4:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 22 14.86 750 2 2
2 7 2003.32 53 13.97 3632 2 2
3 13 1742.24 37 13.92 3294 2 2
4 13 954.72 37 14.33 2211 2 2
5 13 173.48 37 14.77 1035 2 2
6 13 36.04 37 14.87 728 2 2
7 8 0.04 150 14.81 632 2 5

Cycle 288 GMT 17/ 8/2024 5:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 22 14.90 751 2 2
2 7 2007.24 54 13.98 3629 2 2
3 13 1604.64 37 13.97 3137 2 2
4 13 733.12 37 14.47 1913 2 2
5 13 138.96 37 14.80 972 2 2
6 13 14.28 37 14.88 690 2 2
7 8 0.00 150 14.80 633 2 4

Cycle 287 GMT 7/ 8/2024 5:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 22 14.88 750 2 2
2 7 2002.64 53 14.00 3598 2 2
3 13 1599.08 37 14.01 3042 2 2
4 13 1015.48 37 14.28 2255 2 2
5 13 131.20 37 14.81 966 2 2
6 8 0.04 150 14.84 639 2 3

Cycle 286 GMT 28/ 7/2024 5:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 22 14.84 725 2 2
2 7 2004.88 53 14.01 3611 2 2
3 13 1466.00 37 14.04 2879 2 2
4 13 755.84 37 14.38 1878 2 2
5 13 139.36 37 14.78 998 2 2
6 8 0.16 150 14.84 625 2 4

Cycle 285 GMT 18/ 7/2024 6: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 22 14.93 735 2 2
2 7 2004.08 54 13.99 3621 2 2
3 13 1595.32 37 13.95 3136 2 2
4 13 841.84 37 14.36 1940 2 2
5 13 181.96 37 14.72 1112 2 2
6 13 19.44 37 14.86 704 2 2
7 8 0.00 150 14.78 631 2 7

Cycle 284 GMT 8/ 7/2024 6:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 22 14.88 752 2 2
2 7 2002.72 53 13.98 3616 2 2
3 13 1601.08 37 13.98 3129 2 2
4 13 874.96 37 14.35 2028 2 2
5 13 157.64 37 14.82 954 2 2
6 8 0.12 150 14.88 600 2 2

Cycle 283 GMT 28/ 6/2024 6:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 22 14.90 748 2 2
2 7 2002.72 54 13.99 3611 2 2
3 13 1730.12 37 13.97 3233 2 2
4 13 800.56 37 14.43 1921 2 2
5 13 159.24 37 14.76 1045 2 2
6 8 0.04 150 14.84 635 2 5

Cycle 282 GMT 18/ 6/2024 6:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 22 14.90 745 2 2
2 7 2006.04 54 13.99 3619 2 2
3 13 1739.04 37 13.95 3210 2 2
4 13 848.64 37 14.30 2142 2 2
5 13 125.88 37 14.83 929 2 2
6 8 0.12 150 14.86 624 2 2

Cycle 281 GMT 8/ 6/2024 7:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 22 14.90 734 2 2
2 7 2009.48 53 13.99 3652 2 2
3 13 1465.32 37 14.09 2883 2 2
4 13 741.16 37 14.42 1885 2 2
5 13 136.32 37 14.80 949 2 2
6 8 0.04 150 14.85 626 2 3

Cycle 280 GMT 29/ 5/2024 7:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 22 14.91 745 2 2
2 7 2005.56 53 13.97 3636 2 2
3 13 1733.12 37 13.94 3211 2 2
4 13 812.88 37 14.42 1972 2 2
5 13 164.24 37 14.78 1028 2 2
6 8 0.04 150 14.86 621 2 2

Cycle 279 GMT 19/ 5/2024 7:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 22 14.89 762 2 2
2 7 2003.64 54 13.97 3627 2 2
3 13 1733.36 37 13.91 3325 2 2
4 13 830.20 37 14.34 2029 2 2
5 13 132.00 37 14.84 938 2 2
6 8 -0.04 150 14.87 629 2 3

Cycle 278 GMT 9/ 5/2024 7:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 22 14.90 752 2 2
2 7 2006.92 53 14.00 3586 2 2
3 13 1581.20 37 14.04 3016 2 2
4 13 694.32 37 14.45 1820 2 2
5 13 122.92 37 14.80 944 2 2
6 8 0.12 150 14.84 634 2 3

Cycle 277 GMT 29/ 4/2024 8: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 22 14.88 701 2 2
2 7 2005.92 54 14.00 3568 2 2
3 13 1733.64 37 13.91 3262 2 2
4 13 848.68 37 14.39 2000 2 2
5 13 131.44 37 14.83 925 2 2
6 8 0.00 150 14.86 622 2 2

Cycle 276 GMT 19/ 4/2024 8:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 21 14.91 706 2 2
2 7 2006.04 53 13.96 3588 2 2
3 13 1587.36 37 14.05 2952 2 2
4 13 989.08 37 14.27 2159 2 2
5 13 160.88 37 14.76 1040 2 2
6 8 0.00 150 14.84 620 2 3

Cycle 275 GMT 9/ 4/2024 8:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 22 14.88 736 2 2
2 7 2003.60 53 14.02 3612 2 2
3 13 1442.00 37 13.99 2869 2 2
4 13 709.28 37 14.45 1747 2 2
5 13 129.24 37 14.81 919 2 2
6 8 0.04 150 14.85 600 2 4

Cycle 274 GMT 30/ 3/2024 8:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 22 14.88 737 2 2
2 7 2002.40 53 13.97 3614 2 2
3 13 1742.08 37 13.93 3287 2 2
4 13 670.88 37 14.46 1771 2 2
5 13 96.72 37 14.81 909 2 2
6 8 0.00 150 14.82 642 2 3

Cycle 273 GMT 20/ 3/2024 9: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 21 14.87 727 2 2
2 7 2003.28 53 14.00 3604 2 2
3 13 1742.44 37 13.89 3221 2 2
4 13 708.40 37 14.44 1849 2 2
5 13 113.12 37 14.81 930 2 2
6 8 0.04 150 14.83 630 2 5

Cycle 272 GMT 10/ 3/2024 8:55: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 21 14.85 728 2 2
2 7 2002.32 53 13.98 3603 2 2
3 13 1736.44 37 14.01 3261 2 2
4 13 936.32 37 14.29 2153 2 2
5 13 115.84 37 14.79 962 2 2
6 8 0.08 150 14.82 639 2 3

Cycle 271 GMT 29/ 2/2024 9:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 21 14.90 734 2 2
2 7 2002.88 53 14.00 3576 2 2
3 13 1450.76 37 14.08 2853 2 2
4 13 716.08 37 14.43 1856 2 2
5 13 94.12 37 14.80 918 2 2
6 8 -0.08 150 14.80 644 2 5

Cycle 270 GMT 19/ 2/2024 9:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 22 14.88 738 2 2
2 3 972.04 -1 15.40 2 2 2
3 7 2008.48 53 14.00 3576 2 2
4 13 1880.64 37 13.89 3415 2 2
5 13 561.20 37 14.55 1638 2 2
6 13 117.08 37 14.80 947 2 2
7 8 0.04 150 14.83 624 2 5

Cycle 269 GMT 9/ 2/2024 10:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 22 14.88 727 2 2
2 7 2004.52 53 14.01 3539 2 2
3 13 1873.52 37 13.85 3435 2 2
4 13 658.16 37 14.51 1778 2 2
5 13 106.32 37 14.82 912 2 2
6 8 0.08 150 14.84 621 2 3

Cycle 268 GMT 30/ 1/2024 10:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 22 14.90 707 2 2
2 7 2003.40 53 14.03 3455 2 2
3 13 1468.40 37 14.14 2884 2 2
4 13 737.20 37 14.41 1892 2 2
5 13 123.20 37 14.80 956 2 2
6 8 0.12 150 14.83 613 2 3

Cycle 267 GMT 20/ 1/2024 10:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 22 14.88 713 2 2
2 7 2004.48 54 13.99 3606 2 2
3 13 1728.40 37 13.92 3240 2 2
4 13 606.08 37 14.52 1695 2 2
5 13 83.32 37 14.85 832 2 2
6 8 0.08 150 14.84 610 2 4

Cycle 266 GMT 10/ 1/2024 10:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 21 14.88 710 2 2
2 7 2005.40 53 14.01 3546 2 2
3 13 1604.56 37 13.98 2959 2 2
4 13 719.16 37 14.47 1788 2 2
5 13 118.64 37 14.80 926 2 2
6 8 -0.08 150 14.83 626 2 4

Cycle 265 GMT 31/12/2023 11: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 21 14.89 703 2 2
2 7 2004.24 53 14.02 3526 2 2
3 13 1461.68 37 14.12 2734 2 2
4 13 591.60 37 14.51 1684 2 2
5 13 76.44 37 14.85 824 2 2
6 8 0.04 150 14.83 622 2 3

Cycle 264 GMT 21/12/2023 10:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 22 14.87 717 2 2
2 7 2008.08 53 14.00 3556 2 2
3 13 1581.44 37 13.99 3060 2 2
4 13 670.28 37 14.48 1817 2 2
5 13 98.08 37 14.81 888 2 2
6 8 0.04 150 14.83 615 2 5

Cycle 263 GMT 11/12/2023 11: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 22 14.88 708 2 2
2 7 2003.40 54 14.01 3541 2 2
3 13 1588.00 37 14.02 3011 2 2
4 13 664.80 37 14.48 1781 2 2
5 13 84.76 37 14.81 889 2 2
6 8 0.00 150 14.82 627 2 3

Cycle 262 GMT 1/12/2023 11:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 20 14.88 712 2 2
2 3 1050.24 1 14.98 2342 2 2
3 7 2003.76 54 14.02 3532 2 2
4 13 1717.84 37 14.03 3137 2 2
5 13 793.92 37 14.44 1950 2 2
6 13 75.52 37 14.84 834 2 2
7 8 0.04 150 14.82 623 2 3

Cycle 261 GMT 21/11/2023 11:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 21 14.83 702 2 2
2 3 965.88 -1 15.37 2 2 2
3 7 2006.28 53 14.01 3588 2 2
4 13 1606.80 37 14.02 2978 2 2
5 13 680.48 37 14.47 1801 2 2
6 13 86.12 37 14.82 862 2 2
7 8 0.00 150 14.82 615 2 4

Cycle 260 GMT 11/11/2023 11:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 21 14.87 697 2 2
2 7 2005.16 53 14.03 3553 2 2
3 13 1579.40 37 14.07 2984 2 2
4 13 664.60 37 14.47 1770 2 2
5 13 92.68 37 14.81 875 2 2
6 13 19.68 37 14.84 703 2 2
7 8 -0.12 150 14.77 624 2 9

Cycle 259 GMT 1/11/2023 11:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 22 14.87 706 2 2
2 7 2004.64 53 14.04 3521 2 2
3 13 1741.08 37 13.91 3235 2 2
4 13 781.56 37 14.40 1943 2 2
5 13 127.76 37 14.78 943 2 2
6 13 25.32 37 14.84 699 2 2
7 8 -0.04 150 14.78 607 2 5

Cycle 258 GMT 22/10/2023 12:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 22 14.87 699 2 2
2 7 2002.52 54 14.02 3563 2 2
3 13 1596.56 37 14.00 3089 2 2
4 13 677.28 37 14.47 1766 2 2
5 13 93.96 37 14.80 885 2 2
6 8 0.12 150 14.82 607 2 4

Cycle 257 GMT 12/10/2023 12:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 21 14.86 718 2 2
2 7 2002.56 53 14.02 3502 2 2
3 13 1456.92 37 14.01 2904 2 2
4 13 854.88 37 14.36 2050 2 2
5 13 95.20 37 14.81 865 2 2
6 8 0.00 150 14.82 607 2 2

Cycle 256 GMT 2/10/2023 13:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 21 14.88 678 2 2
2 7 2005.12 53 14.02 3503 2 2
3 13 1570.96 37 14.03 2991 2 2
4 13 676.04 37 14.48 1788 2 2
5 13 98.36 37 14.82 858 2 2
6 8 0.00 150 14.83 597 2 3

Cycle 255 GMT 22/ 9/2023 13:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 21 14.87 686 2 2
2 7 2006.40 53 14.04 3533 2 2
3 13 1606.80 37 14.08 3008 2 2
4 13 708.44 37 14.47 1838 2 2
5 13 112.44 37 14.79 909 2 2
6 8 0.08 150 14.82 601 2 4

Cycle 254 GMT 12/ 9/2023 14: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 21 14.89 704 2 2
2 7 2001.72 54 14.04 3521 2 2
3 13 1571.12 37 14.04 2953 2 2
4 13 675.00 37 14.48 1728 2 2
5 13 101.32 37 14.80 871 2 2
6 8 0.12 150 14.82 599 2 4

Cycle 253 GMT 2/ 9/2023 14:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 22 14.89 682 2 2
2 7 2003.24 54 14.05 3489 2 2
3 13 1733.20 37 13.94 3218 2 2
4 13 671.96 37 14.47 1776 2 2
5 13 100.32 37 14.81 859 2 2
6 8 0.16 150 14.83 595 2 3

Cycle 252 GMT 23/ 8/2023 14:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 21 14.88 699 2 2
2 7 2005.44 53 14.03 3535 2 2
3 13 1738.56 37 14.00 3176 2 2
4 13 846.20 37 14.37 2016 2 2
5 13 108.68 37 14.81 864 2 2
6 8 0.04 150 14.83 587 2 3

Cycle 251 GMT 13/ 8/2023 14:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 21 14.88 708 2 2
2 7 2009.00 54 14.03 3539 2 2
3 13 1591.64 37 14.07 2890 2 2
4 13 706.72 37 14.46 1832 2 2
5 13 109.88 37 14.80 858 2 2
6 8 0.00 150 14.83 586 2 4

Cycle 250 GMT 3/ 8/2023 15:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 22 14.87 711 2 2
2 7 2005.56 53 14.01 3564 2 2
3 13 1872.52 37 13.91 3378 2 2
4 13 618.40 37 14.49 1719 2 2
5 13 92.60 37 14.84 816 2 2
6 8 0.12 150 14.83 587 2 3

Cycle 249 GMT 24/ 7/2023 15:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 22 14.89 699 2 2
2 7 2004.48 53 14.04 3442 2 2
3 13 1588.48 37 14.06 2894 2 2
4 13 606.56 37 14.50 1681 2 2
5 13 88.20 37 14.83 808 2 2
6 8 0.08 150 14.82 593 2 3

Cycle 248 GMT 14/ 7/2023 15:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 21 14.89 694 2 2
2 3 1036.16 1 14.88 2021 2 2
3 7 2003.84 53 14.02 3548 2 2
4 13 1733.20 37 13.96 3218 2 2
5 13 831.12 37 14.40 2000 2 2
6 13 104.76 37 14.83 829 2 2
7 8 0.08 150 14.84 582 2 3

Cycle 247 GMT 4/ 7/2023 15:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 21 14.87 667 2 2
2 3 972.04 -1 15.39 1 2 2
3 7 2003.92 53 14.04 3528 2 2
4 13 1735.72 37 14.03 3140 2 2
5 13 821.48 37 14.40 1957 2 2
6 13 104.48 37 14.82 840 2 2
7 8 0.12 150 14.84 582 2 3

Cycle 246 GMT 24/ 6/2023 15:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 22 14.88 680 2 2
2 7 2005.92 53 14.08 3479 2 2
3 13 1460.04 37 14.14 2739 2 2
4 13 724.80 37 14.45 1853 2 2
5 13 120.28 37 14.78 895 2 2
6 8 0.00 150 14.82 594 2 4

Cycle 245 GMT 14/ 6/2023 16: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 22 14.87 696 2 2
2 7 2004.64 53 14.06 3473 2 2
3 13 1460.48 37 14.09 2840 2 2
4 13 710.60 37 14.42 1795 2 2
5 13 115.80 37 14.79 881 2 2
6 8 0.08 150 14.82 587 2 3

Cycle 244 GMT 4/ 6/2023 16:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 22 14.87 674 2 2
2 7 2004.52 53 14.02 3540 2 2
3 13 1741.52 37 14.03 3104 2 2
4 13 812.52 37 14.44 1908 2 2
5 13 157.40 37 14.76 951 2 2
6 8 0.08 150 14.82 590 2 3

Cycle 243 GMT 25/ 5/2023 16:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 22 14.88 701 2 2
2 7 2003.44 54 14.02 3542 2 2
3 13 1466.20 37 14.15 2717 2 2
4 13 596.88 37 14.50 1647 2 2
5 13 141.92 37 14.78 906 2 2
6 13 13.32 37 14.87 619 2 2
7 8 -0.04 150 14.80 572 2 8

Cycle 242 GMT 15/ 5/2023 16:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 22 14.87 676 2 2
2 7 2004.44 53 14.06 3495 2 2
3 13 1730.00 37 14.02 3154 2 2
4 13 978.88 37 14.33 2160 2 2
5 13 175.04 37 14.75 1003 2 2
6 8 0.16 150 14.84 574 2 3

Cycle 241 GMT 5/ 5/2023 16:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 22 14.88 695 2 2
2 7 2002.84 54 14.06 3445 2 2
3 13 1594.64 37 14.09 2924 2 2
4 13 697.08 37 14.43 1821 2 2
5 13 112.44 37 14.81 852 2 2
6 8 0.04 150 14.83 583 2 3

Cycle 240 GMT 25/ 4/2023 16:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 21 14.86 700 2 2
2 3 1040.12 1 15.16 1763 2 2
3 7 2005.84 53 14.03 3509 2 2
4 13 1596.48 37 14.08 2894 2 2
5 13 797.80 37 14.42 1874 2 2
6 13 105.72 37 14.82 830 2 2
7 8 0.16 150 14.84 580 2 3

Cycle 239 GMT 15/ 4/2023 16:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 22 14.84 681 2 2
2 3 956.44 -1 15.39 1 2 2
3 7 2006.20 54 14.03 3543 2 2
4 13 1348.00 37 14.13 2683 2 2
5 13 738.24 37 14.45 1805 2 2
6 13 115.36 37 14.78 887 2 2
7 8 0.08 150 14.81 603 2 3

Cycle 238 GMT 5/ 4/2023 16:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 22 14.85 699 2 2
2 7 2003.88 53 14.03 3504 2 2
3 13 1584.32 37 14.06 2958 2 2
4 13 595.20 37 14.52 1641 2 2
5 13 127.04 37 14.78 904 2 2
6 8 0.08 150 14.81 619 2 3

Cycle 237 GMT 26/ 3/2023 17: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 22 14.86 734 2 2
2 7 2005.24 53 14.02 3533 2 2
3 13 1581.84 37 14.09 2827 2 2
4 13 807.44 37 14.42 1837 2 2
5 13 149.32 37 14.74 981 2 2
6 8 0.08 150 14.79 627 2 4

Cycle 236 GMT 16/ 3/2023 17:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 22 14.83 731 2 2
2 7 2005.80 54 14.04 3513 2 2
3 13 1448.24 37 14.22 2575 2 2
4 13 723.88 37 14.45 1854 2 2
5 13 116.04 37 14.78 900 2 2
6 8 0.08 150 14.80 628 2 3

Cycle 235 GMT 6/ 3/2023 17:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 21 14.85 706 2 2
2 3 1026.80 1 14.93 2170 2 2
3 7 2007.32 53 14.07 3449 2 2
4 13 1727.80 37 14.04 3106 2 2
5 13 916.52 37 14.34 2072 2 2
6 13 121.00 37 14.78 905 2 2
7 8 0.04 150 14.80 621 2 3

Cycle 234 GMT 24/ 2/2023 18: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 21 14.84 717 2 2
2 7 2002.00 54 14.07 3476 2 2
3 13 1453.96 37 14.12 2806 2 2
4 13 688.20 37 14.42 1815 2 2
5 13 98.20 37 14.80 838 2 2
6 8 0.20 150 14.79 610 2 2

Cycle 233 GMT 14/ 2/2023 18:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 21 14.85 692 2 2
2 3 966.60 -1 15.39 1 2 2
3 7 2003.92 53 14.11 3412 2 2
4 13 1729.76 37 14.07 3096 2 2
5 13 805.96 37 14.44 1861 2 2
6 13 145.44 37 14.75 935 2 2
7 8 0.04 150 14.80 604 2 4

Cycle 232 GMT 4/ 2/2023 18:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 21 14.88 700 2 2
2 7 2006.24 53 14.04 3477 2 2
3 13 1587.76 37 14.05 2956 2 2
4 13 580.88 37 14.50 1622 2 2
5 13 124.76 37 14.78 897 2 2
6 8 0.08 150 14.80 598 2 3

Cycle 231 GMT 25/ 1/2023 17:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 22 14.82 721 2 2
2 7 2003.56 54 14.08 3448 2 2
3 13 1465.96 37 14.13 2850 2 2
4 13 601.16 37 14.50 1624 2 2
5 13 81.04 37 14.84 766 2 2
6 8 0.00 150 14.83 584 2 3

Cycle 230 GMT 15/ 1/2023 17:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 22 14.86 691 2 2
2 7 2002.08 53 14.10 3416 2 2
3 13 1428.24 37 14.16 2663 2 2
4 13 560.64 37 14.52 1512 2 2
5 13 106.80 37 14.77 858 2 2
6 8 -0.08 150 14.78 608 2 4

Cycle 229 GMT 5/ 1/2023 17:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 21 14.87 692 2 2
2 3 1028.04 1 15.24 1605 2 2
3 3 1019.00 1 15.03 2312 2 2
4 7 2004.84 53 14.09 3393 2 2
5 13 1591.92 37 14.11 2929 2 2
6 13 983.08 37 14.34 2087 2 2
7 13 145.88 37 14.76 913 2 2
8 8 0.08 150 14.81 586 2 3

Cycle 228 GMT 26/12/2022 18:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 21 14.86 680 2 2
2 3 968.48 -1 15.39 1 2 2
3 7 2005.88 53 14.03 3478 2 2
4 13 1735.08 37 14.00 3121 2 2
5 13 656.00 37 14.48 1694 2 2
6 13 103.88 37 14.81 800 2 2
7 8 0.04 150 14.83 574 2 3

Cycle 227 GMT 16/12/2022 18:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 21 14.87 669 2 2
2 7 2005.84 54 14.08 3405 2 2
3 13 1875.64 37 13.93 3294 2 2
4 13 631.56 37 14.49 1661 2 2
5 13 100.04 37 14.83 781 2 2
6 8 0.24 150 14.83 563 2 4

Cycle 226 GMT 6/12/2022 18: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 21 14.87 663 2 2
2 7 2008.52 53 14.12 3424 2 2
3 13 1483.92 37 14.19 2724 2 2
4 13 739.12 37 14.46 1728 2 2
5 13 124.24 37 14.79 843 2 2
6 8 -0.04 150 14.82 570 2 3

Cycle 225 GMT 26/11/2022 18:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 21 14.85 664 2 2
2 7 2001.80 53 14.07 3420 2 2
3 13 1584.52 37 14.13 2837 2 2
4 13 707.00 37 14.47 1663 2 2
5 13 113.52 37 14.80 793 2 2
6 8 0.04 150 14.83 554 2 3

Cycle 224 GMT 16/11/2022 18:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 21 14.89 658 2 2
2 7 2004.08 53 14.07 3393 2 2
3 13 1578.60 37 14.12 2862 2 2
4 13 511.88 37 14.58 1430 2 2
5 13 114.16 37 14.81 796 2 2
6 8 0.08 150 14.81 559 2 3

Cycle 223 GMT 6/11/2022 18:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 20 14.87 665 2 2
2 3 1040.36 1 14.73 2343 2 2
3 7 2006.40 53 14.09 3389 2 2
4 13 1593.00 37 14.12 2812 2 2
5 13 662.48 37 14.50 1618 2 2
6 13 96.16 37 14.83 734 2 2
7 8 0.16 150 14.82 539 2 3

Cycle 222 GMT 27/10/2022 18:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 21 14.85 622 2 2
2 3 966.88 -1 15.39 2 2 2
3 7 2006.56 54 14.08 3366 2 2
4 13 1740.04 37 14.06 3085 2 2
5 13 651.72 37 14.51 1585 2 2
6 13 98.44 37 14.83 737 2 2
7 8 0.08 150 14.83 535 2 4

Cycle 221 GMT 17/10/2022 18:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 21 14.88 632 2 2
2 7 2014.76 53 14.08 3376 2 2
3 13 1322.52 37 14.22 2454 2 2
4 13 575.64 37 14.55 1443 2 2
5 13 105.20 37 14.80 750 2 2
6 8 0.04 150 14.80 538 2 6

Cycle 220 GMT 7/10/2022 18:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 21 14.85 632 2 2
2 7 2006.88 53 14.09 3405 2 2
3 13 1877.20 37 13.98 3259 2 2
4 13 754.44 37 14.46 1733 2 2
5 13 115.48 37 14.81 765 2 2
6 8 0.00 150 14.83 522 2 3

Cycle 219 GMT 27/ 9/2022 19:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 21 14.87 631 2 2
2 7 2007.80 53 14.11 3406 2 2
3 13 1437.00 37 14.21 2592 2 2
4 13 518.68 37 14.58 1397 2 2
5 13 107.44 37 14.81 741 2 2
6 8 0.00 150 14.82 523 2 3

Cycle 218 GMT 17/ 9/2022 19:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 21 14.87 618 2 2
2 3 965.40 -1 15.36 1 2 2
3 7 2003.92 53 14.10 3366 2 2
4 13 1740.24 37 14.03 3024 2 2
5 13 567.64 37 14.56 1460 2 2
6 13 125.12 37 14.80 778 2 2
7 8 0.00 150 14.82 524 2 3

Cycle 217 GMT 7/ 9/2022 19:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 22 14.87 642 2 2
2 7 2002.80 53 14.10 3368 2 2
3 13 1731.20 37 14.07 2968 2 2
4 13 644.48 37 14.53 1569 2 2
5 13 86.76 37 14.84 686 2 2
6 8 0.04 150 14.83 517 2 3

Cycle 216 GMT 28/ 8/2022 20: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 21 14.86 631 2 2
2 3 1026.36 1 15.25 1762 2 2
3 7 2003.72 54 14.14 3302 2 2
4 13 1722.60 37 14.08 3076 2 2
5 13 667.92 37 14.50 1583 2 2
6 13 109.32 37 14.82 724 2 2
7 8 0.16 150 14.83 514 2 3

Cycle 215 GMT 18/ 8/2022 19:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 21 14.89 625 2 2
2 7 2009.96 53 14.08 3404 2 2
3 13 1883.88 37 13.97 3252 2 2
4 13 804.68 37 14.45 1798 2 2
5 13 138.72 37 14.78 807 2 2
6 8 0.00 150 14.82 515 2 2

Cycle 214 GMT 8/ 8/2022 19:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 21 14.86 631 2 2
2 7 2003.56 54 14.14 3339 2 2
3 13 1727.04 37 14.04 3013 2 2
4 13 789.80 37 14.43 1747 2 2
5 13 96.52 37 14.83 688 2 2
6 8 0.08 150 14.84 505 2 3

Cycle 213 GMT 29/ 7/2022 19:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 21 14.89 627 2 2
2 7 2005.32 53 14.07 3424 2 2
3 13 1444.44 37 14.14 2672 2 2
4 13 549.72 37 14.54 1456 2 2
5 13 120.48 37 14.80 746 2 2
6 8 0.00 150 14.81 517 2 3

Cycle 212 GMT 19/ 7/2022 20:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 21 14.85 626 2 2
2 7 2006.04 53 14.10 3370 2 2
3 13 1743.52 37 14.04 3133 2 2
4 13 832.96 37 14.42 1855 2 2
5 13 115.88 37 14.81 727 2 2
6 8 0.04 150 14.84 495 2 2

Cycle 211 GMT 9/ 7/2022 20:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 22 14.85 622 2 2
2 7 2005.16 53 14.09 3367 2 2
3 13 1477.40 37 14.11 2691 2 2
4 13 591.68 37 14.51 1512 2 2
5 13 137.04 37 14.77 798 2 2
6 8 0.04 150 14.81 514 2 3

Cycle 210 GMT 29/ 6/2022 20: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 22 14.88 627 2 2
2 7 2005.20 53 14.14 3363 2 2
3 13 1601.16 37 14.14 2743 2 2
4 13 659.20 37 14.50 1577 2 2
5 13 108.92 37 14.81 712 2 2
6 8 0.08 150 14.82 508 2 2

Cycle 209 GMT 19/ 6/2022 19:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 21 14.85 627 2 2
2 7 2003.88 54 14.14 3281 2 2
3 13 1742.20 37 14.01 3128 2 2
4 13 569.00 37 14.54 1455 2 2
5 13 130.04 37 14.79 772 2 2
6 8 0.08 150 14.83 507 2 3

Cycle 208 GMT 9/ 6/2022 20: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 21 14.88 629 2 2
2 7 2007.20 53 14.10 3403 2 2
3 13 1885.64 37 14.00 3210 2 2
4 13 624.92 37 14.53 1490 2 2
5 13 144.20 37 14.77 808 2 2
6 8 0.00 150 14.82 504 2 3

Cycle 207 GMT 30/ 5/2022 20: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 22 14.86 624 2 2
2 7 2017.80 53 14.09 3402 2 2
3 13 1895.68 37 13.99 3251 2 2
4 13 820.20 37 14.42 1776 2 2
5 13 122.20 37 14.81 733 2 2
6 8 0.08 150 14.84 494 2 3

Cycle 206 GMT 20/ 5/2022 20:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 21 14.87 612 2 2
2 3 1024.56 1 15.06 1755 2 2
3 7 2004.12 53 14.09 3381 2 2
4 13 1315.28 37 14.23 2330 2 2
5 13 716.72 37 14.45 1681 2 2
6 13 125.84 37 14.78 743 2 2
7 8 0.08 150 14.81 497 2 3

Cycle 205 GMT 10/ 5/2022 20:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 21 14.86 610 2 2
2 7 2002.84 53 14.10 3393 2 2
3 13 1470.88 37 14.07 2708 2 2
4 13 862.44 37 14.41 1864 2 2
5 13 123.04 37 14.79 723 2 2
6 8 0.04 150 14.82 487 2 2

Cycle 204 GMT 30/ 4/2022 20:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 21 14.85 594 2 2
2 7 2003.12 54 14.10 3390 2 2
3 13 1574.36 37 14.15 2833 2 2
4 13 786.32 37 14.41 1725 2 2
5 13 153.12 37 14.75 790 2 2
6 8 -0.08 150 14.82 488 2 3

Cycle 203 GMT 20/ 4/2022 20:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 21 14.85 597 2 2
2 7 2001.80 54 14.14 3344 2 2
3 13 1455.64 37 14.17 2605 2 2
4 13 842.76 37 14.36 1862 2 2
5 13 123.28 37 14.79 725 2 2
6 8 0.00 150 14.82 479 2 3

Cycle 202 GMT 10/ 4/2022 20:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 21 14.86 600 2 2
2 7 2008.92 53 14.14 3318 2 2
3 13 1445.36 37 14.20 2575 2 2
4 13 984.68 37 14.35 1978 2 2
5 13 160.92 37 14.74 813 2 2
6 8 -0.12 150 14.80 491 2 3

Cycle 201 GMT 31/ 3/2022 21:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 21 14.83 627 2 2
2 7 2008.88 53 14.13 3331 2 2
3 13 1588.04 37 14.08 2739 2 2
4 13 690.48 37 14.47 1575 2 2
5 13 120.72 37 14.79 730 2 2
6 8 0.08 150 14.81 493 2 4

Cycle 200 GMT 21/ 3/2022 21:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 21 14.84 628 2 2
2 7 2002.88 53 14.14 3405 2 2
3 13 1589.24 37 14.14 2829 2 2
4 13 675.88 37 14.46 1557 2 2
5 13 163.64 37 14.72 821 2 2
6 8 -0.08 150 14.79 496 2 3

Cycle 199 GMT 11/ 3/2022 21:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 21 14.84 611 2 2
2 7 2002.72 54 14.10 3385 2 2
3 13 1585.24 37 14.10 2758 2 2
4 13 556.88 37 14.52 1440 2 2
5 13 130.92 37 14.77 765 2 2
6 8 -0.04 150 14.80 500 2 3

Cycle 198 GMT 1/ 3/2022 22: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 21 14.86 611 2 2
2 7 2001.72 53 14.12 3327 2 2
3 13 1572.76 37 14.12 2715 2 2
4 13 648.12 37 14.48 1522 2 2
5 13 100.00 37 14.80 679 2 2
6 8 -0.08 150 14.80 492 2 6

Cycle 197 GMT 19/ 2/2022 22:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 21 14.83 622 2 2
2 7 2004.28 53 14.14 3345 2 2
3 13 1742.44 37 14.08 2997 2 2
4 13 1077.56 37 14.27 2217 2 2
5 13 123.04 37 14.78 716 2 2
6 8 0.08 150 14.81 482 2 2

Cycle 196 GMT 9/ 2/2022 22:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 21 14.86 605 2 2
2 7 2002.84 53 14.14 3322 2 2
3 13 1571.56 37 14.15 2670 2 2
4 13 642.96 37 14.48 1573 2 2
5 13 148.28 37 14.74 782 2 2
6 8 0.04 150 14.79 490 2 3

Cycle 195 GMT 30/ 1/2022 22:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 21 14.86 607 2 2
2 7 2001.24 54 14.14 3322 2 2
3 13 1585.24 37 14.18 2679 2 2
4 13 669.60 37 14.47 1571 2 2
5 13 115.12 37 14.79 694 2 2
6 8 0.08 150 14.81 481 2 3

Cycle 194 GMT 20/ 1/2022 23: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 21 14.84 618 2 2
2 7 2002.32 53 14.16 3332 2 2
3 13 1563.20 37 14.13 2823 2 2
4 13 517.44 37 14.56 1375 2 2
5 13 109.68 37 14.80 684 2 2
6 8 0.08 150 14.81 478 2 4

Cycle 193 GMT 10/ 1/2022 23:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 20 14.82 612 2 2
2 3 1030.36 1 15.13 2135 2 2
3 7 2004.08 54 14.15 3340 2 2
4 13 1728.80 37 14.04 2962 2 2
5 13 640.20 37 14.51 1492 2 2
6 13 94.44 37 14.80 676 2 2
7 8 0.04 150 14.80 485 2 3

Cycle 192 GMT 31/12/2021 23:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 21 14.84 588 2 2
2 3 972.76 -1 15.38 1 2 2
3 7 2003.08 53 14.15 3306 2 2
4 13 1434.44 37 14.21 2551 2 2
5 13 556.40 37 14.55 1392 2 2
6 13 109.92 37 14.76 713 2 2
7 8 -0.04 150 14.78 493 2 3

Cycle 191 GMT 22/12/2021 0:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 21 14.83 623 2 2
2 7 2002.36 53 14.18 3226 2 2
3 13 1584.76 37 14.17 2819 2 2
4 13 809.80 37 14.40 1731 2 2
5 13 98.68 37 14.79 673 2 2
6 8 0.00 150 14.80 481 2 3

Cycle 190 GMT 12/12/2021 0:30:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 21 14.84 594 2 2
2 7 2016.12 53 14.11 3387 2 2
3 13 1477.56 37 14.16 2632 2 2
4 13 630.32 37 14.51 1470 2 2
5 13 89.72 37 14.79 664 2 2
6 8 0.00 150 14.79 492 2 5

Cycle 189 GMT 2/12/2021 0: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 21 14.86 595 2 2
2 7 2004.88 53 14.12 3405 2 2
3 13 1732.40 37 14.08 2908 2 2
4 13 663.24 37 14.50 1534 2 2
5 13 96.04 37 14.79 672 2 2
6 8 0.00 150 14.79 487 2 3

Cycle 188 GMT 22/11/2021 0:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 21 14.83 617 2 2
2 3 1021.52 1 15.24 1744 2 2
3 7 2013.88 54 14.12 3364 2 2
4 13 1887.76 37 14.00 3202 2 2
5 13 648.52 37 14.52 1485 2 2
6 13 107.84 37 14.80 685 2 2
7 8 0.08 150 14.80 484 2 3

Cycle 187 GMT 12/11/2021 0:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 21 14.86 594 2 2
2 7 2002.64 53 14.19 3310 2 2
3 13 1583.84 37 14.13 2782 2 2
4 13 943.04 37 14.33 1899 2 2
5 13 126.36 37 14.76 731 2 2
6 8 -0.04 150 14.79 480 2 5

Cycle 186 GMT 2/11/2021 0:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 21 14.83 602 2 2
2 7 2003.00 54 14.10 3363 2 2
3 13 1724.32 37 14.14 2983 2 2
4 13 933.52 37 14.34 1840 2 2
5 13 130.88 37 14.75 746 2 2
6 8 -0.12 150 14.79 485 2 3

Cycle 185 GMT 23/10/2021 0:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 21 14.82 601 2 2
2 7 2007.16 54 14.14 3335 2 2
3 13 1876.32 37 14.05 3095 2 2
4 13 760.28 37 14.42 1685 2 2
5 13 119.88 37 14.76 726 2 2
6 8 0.08 150 14.79 487 2 3

Cycle 184 GMT 13/10/2021 1:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 21 14.85 608 2 2
2 7 2011.12 53 14.15 3337 2 2
3 13 1458.48 37 14.18 2612 2 2
4 13 564.04 37 14.52 1378 2 2
5 13 119.88 37 14.76 717 2 2
6 8 0.04 150 14.78 488 2 3

Cycle 183 GMT 3/10/2021 1:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 21 14.84 590 2 2
2 7 2004.20 53 14.19 3323 2 2
3 13 1584.84 37 14.16 2771 2 2
4 13 653.68 37 14.49 1461 2 2
5 13 96.64 37 14.80 661 2 2
6 8 0.04 150 14.80 471 2 3

Cycle 182 GMT 23/ 9/2021 1:39:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 21 14.84 581 2 2
2 7 2002.68 53 14.21 3229 2 2
3 13 1570.56 37 14.15 2764 2 2
4 13 651.08 37 14.48 1484 2 2
5 13 94.36 37 14.79 650 2 2
6 8 0.08 150 14.79 475 2 3

Cycle 181 GMT 13/ 9/2021 2: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 21 14.85 590 2 2
2 7 2010.92 53 14.14 3318 2 2
3 13 1340.56 37 14.21 2441 2 2
4 13 603.56 37 14.55 1371 2 2
5 13 133.84 37 14.75 731 2 2
6 8 0.04 150 14.80 465 2 3

Cycle 180 GMT 3/ 9/2021 2:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 21 14.85 584 2 2
2 7 2010.48 53 14.17 3341 2 2
3 13 1607.08 37 14.14 2791 2 2
4 13 687.24 37 14.45 1556 2 2
5 13 119.96 37 14.77 711 2 2
6 8 0.08 150 14.80 468 2 3

Cycle 179 GMT 24/ 8/2021 2:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 21 14.83 599 2 2
2 7 2003.52 53 14.15 3416 2 2
3 13 1587.40 37 14.18 2758 2 2
4 13 838.76 37 14.40 1751 2 2
5 13 120.52 37 14.78 699 2 2
6 8 0.08 150 14.81 460 2 3

Cycle 178 GMT 14/ 8/2021 2:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 21 14.85 597 2 2
2 7 2005.52 54 14.19 3335 2 2
3 13 1445.52 37 14.21 2575 2 2
4 13 538.32 37 14.54 1353 2 2
5 13 111.32 37 14.77 692 2 2
6 8 -0.04 150 14.79 472 2 3

Cycle 177 GMT 4/ 8/2021 2:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 21 14.83 600 2 2
2 7 2002.92 53 14.15 3277 2 2
3 13 1723.92 37 14.05 2985 2 2
4 13 660.64 37 14.46 1534 2 2
5 13 103.64 37 14.79 676 2 2
6 8 0.12 150 14.80 476 2 2

Cycle 176 GMT 25/ 7/2021 2:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 21 14.85 591 2 2
2 7 2009.88 53 14.16 3346 2 2
3 13 1593.92 37 14.13 2736 2 2
4 13 534.12 37 14.55 1347 2 2
5 13 116.56 37 14.77 707 2 2
6 8 -0.04 150 14.79 485 2 3

Cycle 175 GMT 15/ 7/2021 2:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 21 14.83 594 2 2
2 7 2002.44 54 14.19 3336 2 2
3 13 1587.04 37 14.13 2788 2 2
4 13 515.04 37 14.53 1328 2 2
5 13 110.44 37 14.78 674 2 2
6 8 0.08 150 14.79 472 2 3

Cycle 174 GMT 5/ 7/2021 2:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 21 14.85 581 2 2
2 7 2004.20 53 14.17 3337 2 2
3 13 1728.80 37 14.09 2995 2 2
4 13 615.00 37 14.48 1460 2 2
5 13 131.60 37 14.75 727 2 2
6 8 0.00 150 14.79 468 2 4

Cycle 173 GMT 25/ 6/2021 2:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 21 14.83 584 2 2
2 7 2003.64 54 14.18 3303 2 2
3 13 1472.40 37 14.23 2553 2 2
4 13 589.44 37 14.50 1427 2 2
5 13 136.40 37 14.76 721 2 2
6 8 0.00 150 14.79 461 2 3

Cycle 172 GMT 15/ 6/2021 2:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 21 14.83 574 2 2
2 7 2008.68 53 14.18 3298 2 2
3 13 1457.40 37 14.17 2619 2 2
4 13 552.68 37 14.53 1341 2 2
5 13 120.36 37 14.77 700 2 2
6 8 0.08 150 14.79 463 2 4

Cycle 171 GMT 5/ 6/2021 2:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 21 14.85 587 2 2
2 7 2005.60 54 14.20 3296 2 2
3 13 1445.92 37 14.21 2590 2 2
4 13 677.08 37 14.46 1544 2 2
5 13 101.24 37 14.78 649 2 2
6 8 0.04 150 14.79 464 2 3

Cycle 170 GMT 26/ 5/2021 3:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 21 14.83 586 2 2
2 7 2004.92 51 14.18 3307 2 2
3 13 1735.80 37 14.12 2941 2 2
4 13 530.48 37 14.56 1319 2 2
5 13 119.08 37 14.79 687 2 2
6 8 0.08 150 14.80 468 2 3

Cycle 169 GMT 16/ 5/2021 3:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 21 14.84 589 2 2
2 7 2006.40 50 14.16 3334 2 2
3 13 1739.24 37 14.12 2867 2 2
4 13 662.00 37 14.48 1543 2 2
5 13 115.00 37 14.79 668 2 2
6 8 0.08 150 14.80 459 2 2

Cycle 168 GMT 6/ 5/2021 3:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 21 14.84 601 2 2
2 7 2006.44 51 14.20 3279 2 2
3 13 1574.68 37 14.16 2737 2 2
4 13 511.72 37 14.57 1289 2 2
5 13 98.72 37 14.79 655 2 2
6 8 -0.08 150 14.79 459 2 3

Cycle 167 GMT 26/ 4/2021 3:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 21 14.83 582 2 2
2 7 2007.48 50 14.20 3352 2 2
3 13 1876.16 37 14.08 3205 2 2
4 13 607.84 37 14.51 1443 2 2
5 13 135.28 37 14.76 724 2 2
6 8 0.00 150 14.80 463 2 3

Cycle 166 GMT 16/ 4/2021 3:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 21 14.84 570 2 2
2 7 2009.68 50 14.21 3337 2 2
3 13 1575.56 37 14.22 2673 2 2
4 13 537.48 37 14.55 1305 2 2
5 13 120.52 37 14.78 682 2 2
6 8 0.08 150 14.79 462 2 5

Cycle 165 GMT 6/ 4/2021 4:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 21 14.84 583 2 2
2 7 2001.92 51 14.21 3270 2 2
3 13 1581.00 37 14.17 2676 2 2
4 13 671.44 37 14.48 1503 2 2
5 13 119.96 37 14.79 669 2 2
6 8 0.04 150 14.80 457 2 3

Cycle 164 GMT 27/ 3/2021 4:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 21 14.83 592 2 2
2 7 2004.52 51 14.21 3306 2 2
3 13 1462.84 37 14.21 2530 2 2
4 13 489.12 37 14.57 1266 2 2
5 13 107.32 37 14.80 651 2 2
6 8 0.04 150 14.80 458 2 3

Cycle 163 GMT 17/ 3/2021 4:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 21 14.82 584 2 2
2 7 2006.72 50 14.19 3296 2 2
3 13 1881.40 37 14.11 3158 2 2
4 13 785.08 37 14.41 1680 2 2
5 13 145.52 37 14.75 739 2 2
6 8 0.04 150 14.80 464 2 5

Cycle 162 GMT 7/ 3/2021 4: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 21 14.83 571 2 2
2 7 2015.96 50 14.20 3335 2 2
3 13 1892.72 37 14.04 3204 2 2
4 13 901.32 37 14.37 1815 2 2
5 13 122.12 37 14.78 685 2 2
6 8 0.08 150 14.79 458 2 3

Cycle 161 GMT 25/ 2/2021 4:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 21 14.82 587 2 2
2 7 2002.16 50 14.21 3303 2 2
3 13 1585.76 37 14.18 2733 2 2
4 13 664.28 37 14.48 1486 2 2
5 13 94.84 37 14.80 625 2 2
6 8 0.04 150 14.80 454 2 3

Cycle 160 GMT 15/ 2/2021 4:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 21 14.83 570 2 2
2 7 2006.68 50 14.21 3320 2 2
3 13 1879.28 37 14.09 3084 2 2
4 13 784.68 37 14.44 1654 2 2
5 13 140.28 37 14.76 712 2 2
6 8 0.04 150 14.80 447 2 2

Cycle 159 GMT 5/ 2/2021 4:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 21 14.84 579 2 2
2 7 2003.08 50 14.21 3320 2 2
3 13 1588.96 37 14.21 2686 2 2
4 13 802.40 37 14.43 1652 2 2
5 13 147.68 37 14.74 731 2 2
6 8 0.08 150 14.79 443 2 3

Cycle 158 GMT 26/ 1/2021 4:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 20 14.83 573 2 2
2 3 1053.48 1 15.15 1572 2 2
3 7 2003.96 50 14.22 3258 2 2
4 13 1446.56 37 14.17 2565 2 2
5 13 701.44 37 14.45 1527 2 2
6 13 126.76 37 14.78 665 2 2
7 8 0.00 150 14.80 439 2 3

Cycle 157 GMT 16/ 1/2021 4:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 21 14.83 548 2 2
2 3 969.68 -1 15.38 0 2 2
3 7 2002.16 50 14.23 3306 2 2
4 13 1590.68 37 14.14 2769 2 2
5 13 565.60 37 14.55 1302 2 2
6 13 129.32 37 14.78 679 2 2
7 8 -0.08 150 14.80 445 2 2

Cycle 156 GMT 6/ 1/2021 5: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 21 14.84 574 2 2
2 7 2002.64 51 14.21 3293 2 2
3 13 1589.56 37 14.15 2771 2 2
4 13 551.00 37 14.56 1296 2 2
5 13 121.76 37 14.80 649 2 2
6 8 0.16 150 14.81 433 2 3

Cycle 155 GMT 27/12/2020 5:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 21 14.83 563 2 2
2 7 2001.96 45 14.23 3322 2 2
3 13 1591.12 37 14.29 2713 2 2
4 13 691.12 37 14.50 1495 2 2
5 13 120.28 37 14.79 650 2 2
6 8 0.04 150 14.81 440 2 3

Cycle 154 GMT 17/12/2020 5:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 21 14.86 563 2 2
2 7 2003.56 46 14.22 3295 2 2
3 13 1733.00 37 14.14 2902 2 2
4 13 806.24 37 14.42 1644 2 2
5 13 99.08 37 14.80 617 2 2
6 8 0.04 150 14.81 437 2 4

Cycle 153 GMT 7/12/2020 5:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 21 14.83 565 2 2
2 7 2001.24 45 14.28 3206 2 2
3 13 1729.80 37 14.19 2877 2 2
4 13 814.72 37 14.42 1692 2 2
5 13 108.96 37 14.80 625 2 2
6 8 0.04 150 14.82 426 2 3

Cycle 152 GMT 27/11/2020 5:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 21 14.84 545 2 2
2 7 2005.36 45 14.23 3288 2 2
3 13 1749.12 37 14.12 2927 2 2
4 13 783.16 37 14.46 1589 2 2
5 13 129.92 37 14.77 671 2 2
6 8 0.08 150 14.81 426 2 3

Cycle 151 GMT 17/11/2020 5:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 21 14.85 553 2 2
2 7 2002.24 45 14.23 3284 2 2
3 13 1614.76 37 14.16 2788 2 2
4 13 710.08 37 14.47 1535 2 2
5 13 113.60 37 14.80 617 2 2
6 8 0.12 150 14.81 415 2 2

Cycle 150 GMT 7/11/2020 5:46: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 21 14.86 534 2 2
2 7 2005.96 45 14.26 3246 2 2
3 13 1873.16 37 14.13 3137 2 2
4 13 923.72 37 14.37 1737 2 2
5 13 133.68 37 14.78 640 2 2
6 8 0.16 150 14.82 405 2 3

Cycle 149 GMT 28/10/2020 6: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 21 14.85 529 2 2
2 7 2008.72 45 14.24 3264 2 2
3 13 1886.08 37 14.12 3097 2 2
4 13 677.32 37 14.50 1429 2 2
5 13 114.92 37 14.80 614 2 2
6 8 0.04 150 14.83 403 2 3

Cycle 148 GMT 18/10/2020 5:37: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 21 14.84 527 2 2
2 7 2003.80 46 14.25 3225 2 2
3 13 1480.56 37 14.21 2611 2 2
4 13 757.16 37 14.49 1550 2 2
5 13 136.28 37 14.78 670 2 2
6 8 0.04 150 14.82 403 2 3

Cycle 147 GMT 8/10/2020 5:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 21 14.86 504 2 2
2 7 2006.36 46 14.28 3242 2 2
3 13 1596.48 37 14.20 2752 2 2
4 13 958.20 37 14.34 1897 2 2
5 13 131.12 37 14.77 634 2 2
6 8 0.00 150 14.81 397 2 2

Cycle 146 GMT 28/ 9/2020 5:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 21 14.87 521 2 2
2 3 1022.80 1 15.26 2044 2 2
3 7 2003.52 46 14.28 3231 2 2
4 13 1749.44 37 14.16 2907 2 2
5 13 832.56 37 14.44 1669 2 2
6 13 104.16 37 14.81 591 2 2
7 8 0.08 150 14.83 392 2 2

Cycle 145 GMT 18/ 9/2020 5:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 21 14.88 520 2 2
2 7 2005.60 42 14.32 3223 2 2
3 13 1881.32 24 14.27 3031 2 2
4 13 1169.72 24 14.27 2131 2 2
5 13 743.32 24 14.49 1582 2 2
6 13 162.04 24 14.80 645 2 2
7 13 85.16 24 14.83 539 2 2
8 8 0.08 150 14.83 392 2 4

Cycle 144 GMT 8/ 9/2020 5: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 21 14.88 519 2 2
2 7 2008.08 42 14.30 3253 2 2
3 13 1876.12 24 14.19 3169 2 2
4 13 1169.16 24 14.39 1951 2 2
5 13 604.60 24 14.58 1305 2 2
6 13 178.80 24 14.79 650 2 2
7 13 51.44 24 14.86 440 2 2
8 8 0.04 150 14.84 389 2 4

Cycle 143 GMT 29/ 8/2020 5: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 21 14.86 501 2 2
2 7 2003.80 42 14.35 3192 2 2
3 13 1739.24 24 14.32 2861 2 2
4 13 1189.24 24 14.27 2215 2 2
5 13 615.80 24 14.55 1385 2 2
6 13 172.28 24 14.77 709 2 2
7 13 50.04 24 14.85 488 2 2
8 8 0.04 150 14.83 393 2 4

Cycle 142 GMT 19/ 8/2020 5: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 21 14.87 506 2 2
2 7 2006.24 41 14.26 3303 2 2
3 13 1879.40 24 14.18 3159 2 2
4 13 1295.28 24 14.38 2090 2 2
5 13 602.04 24 14.60 1310 2 2
6 13 161.84 24 14.77 718 2 2
7 13 81.48 24 14.82 555 2 2
8 8 0.00 150 14.82 403 2 4

Cycle 141 GMT 9/ 8/2020 4:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 21 14.86 498 2 2
2 7 2003.12 41 14.32 3211 2 2
3 13 1734.48 24 14.25 2862 2 2
4 13 1177.68 24 14.41 2026 2 2
5 13 468.52 24 14.67 1112 2 2
6 13 120.48 24 14.84 547 2 2
7 13 65.92 24 14.86 505 2 2
8 8 0.08 150 14.84 395 2 3

Cycle 140 GMT 30/ 7/2020 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 20 14.87 503 2 2
2 3 1043.20 1 14.89 2075 2 2
3 7 2004.52 41 14.25 3298 2 2
4 13 1871.40 24 14.19 3163 2 2
5 13 1439.08 24 14.16 2673 2 2
6 13 829.08 24 14.49 1669 2 2
7 13 221.84 24 14.74 801 2 2
8 13 61.24 24 14.84 504 2 2
9 8 0.20 150 14.83 392 2 3

Cycle 139 GMT 20/ 7/2020 4:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 21 14.86 489 2 2
2 3 963.88 -1 15.39 1 2 2
3 7 2006.76 42 14.30 3323 2 2
4 13 1626.08 24 14.28 2705 2 2
5 13 1220.04 24 14.32 2188 2 2
6 13 519.36 24 14.61 1188 2 2
7 13 137.32 24 14.81 636 2 2
8 13 78.28 24 14.84 528 2 2
9 8 0.16 150 14.83 393 2 3

Cycle 138 GMT 10/ 7/2020 4:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 21 14.86 519 2 2
2 7 2002.48 41 14.32 3222 2 2
3 13 1873.92 24 14.17 3081 2 2
4 13 1441.16 24 14.34 2451 2 2
5 13 547.28 24 14.60 1203 2 2
6 13 144.92 24 14.80 653 2 2
7 13 81.00 24 14.84 536 2 2
8 8 0.00 150 14.83 395 2 3

Cycle 137 GMT 30/ 6/2020 4:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 21 14.85 541 2 2
2 7 2003.00 41 14.32 3224 2 2
3 13 1745.48 24 14.24 2887 2 2
4 13 1199.04 24 14.32 2197 2 2
5 13 760.28 24 14.50 1465 2 2
6 13 160.12 24 14.78 697 2 2
7 13 89.12 24 14.82 564 2 2
8 8 0.04 150 14.82 395 2 3

Cycle 136 GMT 20/ 6/2020 3:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 21 14.86 496 2 2
2 7 2002.72 41 14.31 3257 2 2
3 13 1880.44 24 14.32 3019 2 2
4 13 1182.20 24 14.32 2208 2 2
5 13 762.08 24 14.46 1612 2 2
6 13 158.56 24 14.79 693 2 2
7 13 88.84 24 14.83 551 2 2
8 8 -0.12 150 14.83 401 2 3

Cycle 135 GMT 10/ 6/2020 3:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 21 14.85 524 2 2
2 7 2009.12 41 14.34 3193 2 2
3 13 1611.96 24 14.29 2573 2 2
4 13 1333.04 24 14.31 2327 2 2
5 13 884.92 24 14.44 1666 2 2
6 13 167.40 24 14.79 693 2 2
7 13 92.00 24 14.83 562 2 2
8 8 -0.04 150 14.83 391 2 2

Cycle 134 GMT 31/ 5/2020 3:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 21 14.87 527 2 2
2 7 2002.48 42 14.31 3233 2 2
3 13 1869.76 24 14.29 3013 2 2
4 13 1284.92 24 14.29 2267 2 2
5 13 448.36 24 14.65 1113 2 2
6 13 163.12 24 14.78 730 2 2
7 13 82.40 24 14.83 568 2 2
8 8 -0.04 150 14.82 408 2 3

Cycle 133 GMT 21/ 5/2020 3:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 21 14.86 536 2 2
2 7 2001.96 42 14.35 3141 2 2
3 13 1745.36 24 14.36 2787 2 2
4 13 1342.56 24 14.29 2275 2 2
5 13 493.96 24 14.64 1138 2 2
6 13 132.00 24 14.83 638 2 2
7 13 78.96 24 14.85 546 2 2
8 8 0.24 150 14.84 399 2 3

Cycle 132 GMT 11/ 5/2020 3:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 21 14.87 505 2 2
2 7 2008.20 41 14.38 3159 2 2
3 13 1891.36 24 14.28 3067 2 2
4 13 1473.08 24 14.19 2549 2 2
5 13 731.68 24 14.52 1507 2 2
6 13 151.48 24 14.80 696 2 2
7 13 45.80 24 14.86 489 2 2
8 8 -0.04 150 14.83 410 2 5

Cycle 131 GMT 1/ 5/2020 2:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 21 14.86 508 2 2
2 7 2018.96 41 14.31 3228 2 2
3 13 1908.20 24 14.22 3145 2 2
4 13 996.96 24 14.45 1882 2 2
5 13 397.88 24 14.72 965 2 6
6 13 115.12 24 14.84 553 2 3
7 13 27.68 24 14.89 403 2 2
8 8 -0.04 150 14.85 355 2 7

Cycle 130 GMT 21/ 4/2020 2:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 21 14.87 490 2 2
2 7 2005.88 41 14.32 3180 2 2
3 13 1889.96 24 14.24 3095 2 2
4 13 1294.16 24 14.32 2252 2 2
5 13 510.68 24 14.64 1133 2 6
6 13 105.48 24 14.85 538 2 3
7 13 56.28 24 14.87 461 2 2
8 8 -0.04 150 14.84 359 2 6

Cycle 129 GMT 11/ 4/2020 2:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 21 14.89 491 2 2
2 7 2002.20 41 14.33 3192 2 2
3 13 1873.24 24 14.31 3051 2 2
4 13 994.04 24 14.47 1795 2 2
5 13 561.00 24 14.64 1204 2 2
6 13 124.68 24 14.84 571 2 3
7 13 63.60 24 14.86 461 2 2
8 8 -0.04 150 14.85 349 2 5

Cycle 128 GMT 1/ 4/2020 2:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 20 14.88 513 2 2
2 3 1023.76 1 15.06 1919 2 2
3 7 2008.16 41 14.35 3188 2 2
4 13 1888.68 24 14.27 3074 2 2
5 13 1155.52 24 14.34 2211 2 2
6 13 605.44 24 14.61 1237 2 2
7 13 175.28 24 14.81 654 2 3
8 13 47.00 24 14.89 429 2 2
9 8 0.12 150 14.86 350 2 3

Cycle 127 GMT 22/ 3/2020 2:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 20 14.88 509 2 2
2 7 2008.00 41 14.31 3139 2 2
3 13 1876.08 24 14.21 2960 2 2
4 13 1308.56 24 14.31 2263 2 2
5 13 739.20 24 14.58 1369 2 2
6 13 142.32 24 14.82 595 2 3
7 13 79.60 24 14.86 486 2 2
8 8 0.08 150 14.86 357 2 3

Cycle 126 GMT 12/ 3/2020 2:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 20 14.88 512 2 2
2 7 2005.16 41 14.34 3194 2 2
3 13 1877.48 24 14.30 2983 2 2
4 13 1278.60 24 14.30 2376 2 2
5 13 689.04 24 14.58 1370 2 2
6 13 115.24 24 14.85 564 2 3
7 13 68.20 24 14.86 478 2 2
8 8 0.12 150 14.85 364 2 4

Cycle 125 GMT 2/ 3/2020 2:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 20 14.87 527 2 2
2 7 2007.32 41 14.33 3136 2 2
3 13 1875.24 24 14.23 3032 2 2
4 13 992.32 24 14.49 1812 2 2
5 13 392.56 24 14.72 974 2 4
6 13 113.36 24 14.84 567 2 4
7 8 0.00 150 14.86 371 2 4

Cycle 124 GMT 21/ 2/2020 2:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 20 14.88 519 2 2
2 7 2003.32 41 14.35 3143 2 2
3 13 1588.16 24 14.35 2618 2 2
4 13 864.32 24 14.53 1615 2 2
5 13 154.64 24 14.84 636 2 6
6 13 82.96 24 14.86 522 2 3
7 8 0.00 150 14.86 379 2 5

Cycle 123 GMT 11/ 2/2020 2:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 20 14.88 522 2 2
2 7 2004.16 41 14.35 3146 2 2
3 13 1730.56 24 14.30 2845 2 2
4 13 867.24 24 14.54 1625 2 3
5 13 260.32 24 14.78 790 2 5
6 13 71.16 24 14.87 494 2 3
7 8 0.12 150 14.86 376 2 4

Cycle 122 GMT 1/ 2/2020 2:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 20 14.89 513 2 2
2 7 2005.80 41 14.36 3150 2 2
3 13 1880.12 24 14.29 3006 2 2
4 13 948.32 24 14.51 1727 2 3
5 13 207.84 24 14.81 716 2 4
6 13 62.00 24 14.89 481 2 3
7 8 0.04 150 14.87 380 2 6

Cycle 121 GMT 22/ 1/2020 2:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 20 14.88 518 2 2
2 7 2007.64 41 14.33 3177 2 2
3 13 1882.96 24 14.27 2994 2 2
4 13 747.52 24 14.60 1455 2 3
5 13 190.40 24 14.82 690 2 6
6 13 58.32 24 14.89 474 2 3
7 8 0.08 150 14.87 378 2 5

Cycle 120 GMT 12/ 1/2020 2: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 20 14.88 514 2 2
2 7 2001.04 42 14.33 3175 2 2
3 13 1572.24 24 14.34 2587 2 3
4 13 872.20 24 14.52 1632 2 2
5 13 242.00 24 14.78 763 2 4
6 13 71.52 24 14.87 494 2 3
7 8 0.00 150 14.86 379 2 4

Cycle 119 GMT 2/ 1/2020 2: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 20 14.88 517 2 2
2 7 2001.88 42 14.36 3125 2 2
3 13 1596.12 24 14.33 2632 2 2
4 13 1154.80 24 14.39 2017 2 2
5 13 231.92 24 14.79 749 2 7
6 13 70.04 24 14.88 488 2 3
7 8 0.16 150 14.86 380 2 4

Cycle 118 GMT 23/12/2019 1:48:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 20 14.88 528 2 2
2 7 2002.08 41 14.36 3122 2 2
3 13 1595.80 24 14.34 2623 2 2
4 13 1020.40 24 14.47 1831 2 3
5 13 251.04 24 14.78 783 2 6
6 13 67.72 24 14.87 505 2 3
7 8 0.00 150 14.86 386 2 4

Cycle 117 GMT 13/12/2019 1:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 20 14.88 522 2 2
2 7 2004.00 41 14.34 3164 2 2
3 13 1600.80 24 14.33 2662 2 3
4 13 764.04 24 14.58 1495 2 3
5 13 182.52 24 14.82 690 2 6
6 13 51.68 24 14.89 482 2 3
7 8 0.00 150 14.86 393 2 5

Cycle 116 GMT 3/12/2019 1:30:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 20 14.88 526 2 2
2 7 2009.00 41 14.35 3127 2 2
3 13 1881.24 24 14.27 3036 2 2
4 13 819.84 24 14.56 1593 2 3
5 13 251.56 24 14.79 790 2 7
6 13 64.32 24 14.89 510 2 3
7 8 0.16 150 14.87 387 2 4

Cycle 115 GMT 23/11/2019 1:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 20 14.88 525 2 2
2 7 2004.96 42 14.36 3109 2 2
3 13 1744.80 24 14.30 2856 2 2
4 13 865.96 24 14.54 1636 2 2
5 13 252.68 24 14.79 796 2 6
6 13 57.16 24 14.88 495 2 3
7 8 0.04 150 14.86 388 2 4

Cycle 114 GMT 13/11/2019 1:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 20 14.88 545 2 2
2 3 1020.92 1 15.10 1942 2 2
3 7 2003.76 41 14.34 3191 2 2
4 13 1452.72 24 14.37 2456 2 4
5 13 626.04 24 14.64 1311 2 4
6 13 190.48 24 14.82 709 2 4
7 13 56.12 24 14.88 486 2 3
8 8 0.16 150 14.87 388 2 3

Cycle 113 GMT 3/11/2019 0:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 20 14.89 539 2 2
2 7 2003.92 42 14.36 3131 2 2
3 13 1601.88 24 14.34 2651 2 3
4 13 1034.40 24 14.46 1867 2 3
5 13 153.84 24 14.85 654 2 6
6 13 80.12 24 14.87 526 2 3
7 8 0.00 150 14.87 391 2 4

Cycle 112 GMT 24/10/2019 0:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 20 14.89 540 2 2
2 10 1001.20 3 14.91 1885 2 2
3 3 910.00 -2 15.40 1 2 2
4 7 2006.32 41 14.34 3175 2 2
5 13 1881.20 24 14.27 3045 2 2
6 13 1120.00 24 14.44 1991 2 2
7 13 324.20 24 14.76 898 2 5
8 13 78.92 24 14.87 554 2 4
9 8 0.00 150 14.87 401 2 5

Cycle 111 GMT 14/10/2019 0:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 20 14.88 543 2 2
2 7 2006.36 42 14.36 3131 2 2
3 13 1744.20 24 14.30 2852 2 2
4 13 856.88 24 14.54 1647 2 2
5 13 161.88 24 14.85 675 2 5
6 13 53.12 24 14.90 498 2 3
7 8 0.08 150 14.88 403 2 3

Cycle 110 GMT 4/10/2019 0:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 20 14.89 541 2 2
2 7 2003.72 41 14.34 3171 2 2
3 13 1873.12 24 14.28 2998 2 2
4 13 978.12 24 14.51 1774 2 3
5 13 205.04 24 14.83 726 2 6
6 13 60.92 24 14.90 503 2 3
7 13 31.88 24 14.90 458 2 3
8 8 0.04 150 14.86 403 2 7

Cycle 109 GMT 24/ 9/2019 0: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 20 14.89 512 2 2
2 7 2004.12 41 14.35 3156 2 2
3 13 1598.96 24 14.35 2628 2 2
4 13 776.44 24 14.59 1514 2 3
5 13 191.08 24 14.83 710 2 5
6 13 55.96 24 14.89 500 2 3
7 8 0.04 150 14.87 397 2 4

Cycle 108 GMT 13/ 9/2019 23:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 20 14.91 528 2 2
2 7 2007.96 41 14.37 3102 2 2
3 13 1874.40 24 14.29 2993 2 2
4 13 1063.72 24 14.48 1888 2 2
5 13 282.44 24 14.80 814 2 5
6 13 68.92 24 14.90 491 2 3
7 13 35.80 24 14.90 438 2 3
8 8 0.00 150 14.87 374 2 5

Cycle 107 GMT 3/ 9/2019 23:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 20 14.89 525 2 2
2 7 2001.20 42 14.37 3109 2 2
3 13 1730.28 24 14.33 2794 2 3
4 13 726.00 24 14.62 1432 2 3
5 13 291.92 24 14.79 833 2 5
6 13 78.68 24 14.89 509 2 3
7 8 0.16 150 14.89 376 2 5

Cycle 106 GMT 24/ 8/2019 23:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 20 14.90 528 2 2
2 3 1022.40 1 15.13 1896 2 2
3 7 2002.84 42 14.36 3143 2 2
4 13 1608.24 24 14.34 2655 2 3
5 13 861.80 24 14.54 1641 2 2
6 13 252.52 24 14.80 789 2 5
7 13 69.08 24 14.90 499 2 3
8 8 0.12 150 14.88 379 2 3

Cycle 105 GMT 14/ 8/2019 23:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 20 14.91 522 2 2
2 7 2005.52 41 14.38 3107 2 2
3 13 1605.40 24 14.36 2607 2 2
4 13 882.04 24 14.55 1644 2 2
5 13 170.72 24 14.85 658 2 5
6 13 91.80 24 14.88 539 2 3
7 8 0.00 150 14.89 385 2 3

Cycle 104 GMT 4/ 8/2019 23:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 20 14.91 526 2 2
2 7 2012.20 42 14.37 3115 2 2
3 13 1879.48 24 14.29 3011 2 2
4 13 822.00 24 14.59 1563 2 2
5 13 231.36 24 14.83 755 2 4
6 13 68.56 24 14.92 492 2 3
7 13 36.28 24 14.92 436 2 2
8 8 0.04 150 14.89 373 2 5

Cycle 103 GMT 25/ 7/2019 23: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 21 14.92 514 2 2
2 7 2003.76 41 14.38 3124 2 2
3 13 1730.64 24 14.32 2835 2 2
4 13 851.52 24 14.58 1599 2 3
5 13 147.20 24 14.88 607 2 5
6 13 87.24 24 14.90 518 2 3
7 8 0.08 150 14.90 372 2 4

Cycle 102 GMT 15/ 7/2019 23: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 20 14.92 522 2 2
2 7 2022.04 41 14.36 3147 2 2
3 13 1890.40 24 14.28 3033 2 2
4 13 856.72 24 14.57 1607 2 2
5 13 148.40 24 14.88 629 2 3
6 13 84.24 24 14.91 517 2 3
7 8 0.00 150 14.90 372 2 4

Cycle 101 GMT 5/ 7/2019 22:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 21 14.92 522 2 2
2 7 2006.56 41 14.38 3125 2 2
3 13 1597.56 24 14.38 2598 2 3
4 13 887.88 24 14.55 1649 2 2
5 13 156.80 24 14.87 636 2 3
6 13 90.72 24 14.89 529 2 3
7 8 0.08 150 14.90 372 2 3

Cycle 100 GMT 25/ 6/2019 22:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 20 14.93 512 2 2
2 7 2002.00 41 14.37 3126 2 2
3 13 1567.28 24 14.37 2567 2 2
4 13 845.48 24 14.57 1593 2 2
5 13 143.48 24 14.88 613 2 3
6 13 82.52 24 14.90 506 2 2
7 8 0.00 150 14.90 367 2 4

Cycle 99 GMT 15/ 6/2019 22:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 20 14.91 515 2 2
2 7 2002.76 42 14.38 3129 2 2
3 13 1466.12 24 14.40 2451 2 4
4 13 920.24 24 14.54 1687 2 2
5 13 162.20 24 14.87 639 2 4
6 13 89.84 24 14.90 521 2 3
7 8 -0.04 150 14.91 359 2 4

Cycle 98 GMT 5/ 6/2019 22:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 20 14.91 507 2 2
2 7 2003.92 41 14.37 3132 2 2
3 13 1474.36 24 14.40 2420 2 2
4 13 1048.24 24 14.49 1817 2 2
5 13 144.52 24 14.88 610 2 3
6 13 81.40 24 14.90 512 2 3
7 8 0.00 150 14.89 374 2 4

Cycle 97 GMT 26/ 5/2019 21:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 20 14.92 517 2 2
2 7 2006.56 41 14.37 3147 2 2
3 13 1573.36 24 14.38 2578 2 2
4 13 1118.92 24 14.46 1972 2 2
5 13 315.00 24 14.79 862 2 4
6 13 82.88 24 14.90 521 2 3
7 8 -0.04 150 14.89 373 2 5

Cycle 96 GMT 16/ 5/2019 21:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 20 14.93 512 2 2
2 7 2004.20 42 14.39 3087 2 2
3 13 1593.40 24 14.38 2617 2 3
4 13 871.20 24 14.57 1631 2 3
5 13 274.44 24 14.82 799 2 5
6 13 72.24 24 14.92 496 2 3
7 8 0.04 150 14.91 369 2 3

Cycle 95 GMT 6/ 5/2019 21:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 20 14.93 515 2 2
2 7 2007.76 42 14.38 3152 2 2
3 13 1876.20 24 14.30 3037 2 2
4 13 931.64 24 14.56 1703 2 2
5 13 177.40 24 14.88 669 2 5
6 13 91.48 24 14.91 534 2 4
7 8 0.08 150 14.91 375 2 5

Cycle 94 GMT 26/ 4/2019 22:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 20 14.91 516 2 2
2 7 2002.16 41 14.38 3139 2 2
3 13 1606.52 24 14.37 2650 2 2
4 13 1029.32 24 14.50 1838 2 2
5 13 143.00 24 14.89 618 2 3
6 13 87.48 24 14.91 523 2 3
7 8 0.04 150 14.91 372 2 3

Cycle 93 GMT 16/ 4/2019 21:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 20 14.93 514 2 2
2 7 2013.88 41 14.37 3173 2 2
3 13 1746.64 24 14.33 2817 2 2
4 13 861.40 24 14.58 1619 2 2
5 13 147.12 24 14.89 622 2 3
6 13 79.88 24 14.92 519 2 3
7 13 18.00 24 14.94 405 2 2
8 8 0.00 150 14.89 374 2 9

Cycle 92 GMT 6/ 4/2019 21: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 20 14.92 530 2 2
2 7 2004.44 42 14.39 3095 2 2
3 13 1593.80 24 14.38 2582 2 3
4 13 1022.72 24 14.51 1814 2 2
5 13 139.36 24 14.89 613 2 4
6 13 46.92 24 14.94 466 2 2
7 8 0.08 150 14.91 375 2 6

Cycle 91 GMT 27/ 3/2019 20:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 20 14.92 530 2 2
2 7 2003.44 42 14.38 3101 2 2
3 13 1575.72 24 14.38 2576 2 3
4 13 966.08 24 14.53 1758 2 2
5 13 118.20 24 14.91 583 2 3
6 13 67.92 24 14.92 505 2 3
7 8 0.04 150 14.90 388 2 3

Cycle 90 GMT 17/ 3/2019 21: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 20 14.93 525 2 2
2 7 2003.76 41 14.37 3143 2 2
3 13 1612.96 24 14.38 2618 2 3
4 13 892.00 24 14.57 1651 2 3
5 13 146.48 24 14.89 637 2 3
6 13 79.16 24 14.91 528 2 3
7 8 -0.08 150 14.91 386 2 4

Cycle 89 GMT 7/ 3/2019 21:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 20 14.91 545 2 2
2 7 2004.48 41 14.36 3165 2 2
3 13 1731.76 24 14.33 2828 2 2
4 13 840.16 24 14.60 1592 2 2
5 13 131.92 24 14.91 614 2 3
6 13 72.40 24 14.92 521 2 3
7 8 0.00 150 14.91 387 2 7

Cycle 88 GMT 25/ 2/2019 21:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 20 14.92 539 2 2
2 7 2002.84 41 14.37 3123 2 2
3 13 1599.00 24 14.37 2625 2 3
4 13 1167.76 24 14.44 2043 2 2
5 13 231.76 24 14.84 749 2 4
6 13 60.96 24 14.92 496 2 2
7 8 -0.08 150 14.90 395 2 3

Cycle 87 GMT 15/ 2/2019 21:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 20 14.91 530 2 2
2 7 2002.80 41 14.37 3122 2 2
3 13 1592.20 24 14.37 2608 2 2
4 13 862.56 24 14.57 1637 2 2
5 13 138.08 24 14.89 634 2 3
6 13 74.08 24 14.91 538 2 3
7 8 0.16 150 14.90 403 2 3

Cycle 86 GMT 5/ 2/2019 21:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 20 14.92 521 2 2
2 7 2002.96 41 14.38 3110 2 2
3 13 1729.32 24 14.33 2820 2 2
4 13 980.36 24 14.53 1798 2 2
5 13 227.72 24 14.85 764 2 3
6 13 57.28 24 14.93 501 2 3
7 8 0.00 150 14.91 399 2 5

Cycle 85 GMT 26/ 1/2019 21:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 20 14.92 530 2 2
2 7 2003.56 41 14.36 3158 2 2
3 13 1573.16 24 14.37 2581 2 3
4 13 970.40 24 14.53 1757 2 2
5 13 199.40 24 14.86 704 2 3
6 13 59.12 24 14.93 495 2 3
7 8 0.12 150 14.91 385 2 3

Cycle 84 GMT 16/ 1/2019 20:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 20 14.93 510 2 2
2 7 2001.16 42 14.37 3143 2 2
3 13 1584.40 24 14.37 2622 2 2
4 13 847.72 24 14.59 1611 2 2
5 13 124.28 24 14.90 616 2 3
6 13 40.84 24 14.94 478 2 3
7 8 0.08 150 14.90 396 2 5

Cycle 83 GMT 6/ 1/2019 20:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 20 14.93 560 2 2
2 3 1027.76 1 15.12 1952 2 2
3 7 2003.20 41 14.37 3159 2 2
4 13 1596.80 24 14.37 2653 2 3
5 13 886.40 24 14.57 1663 2 2
6 13 148.84 24 14.90 649 2 3
7 13 47.16 24 14.94 483 2 2
8 8 0.04 150 14.92 389 2 4

Cycle 82 GMT 27/12/2018 20:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 20 14.92 530 2 2
2 7 2011.20 42 14.37 3149 2 2
3 13 1879.40 24 14.30 3006 2 2
4 13 1096.12 24 14.50 1945 2 2
5 13 187.80 24 14.89 691 2 3
6 13 47.92 24 14.95 480 2 2
7 8 0.00 150 14.92 400 2 4

Cycle 81 GMT 17/12/2018 20: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 20 14.93 536 2 2
2 7 2007.12 42 14.38 3125 2 2
3 13 1481.04 24 14.41 2486 2 3
4 13 913.12 24 14.55 1715 2 2
5 13 150.32 24 14.89 648 2 3
6 13 37.04 24 14.93 473 2 3
7 8 -0.04 150 14.90 401 2 4

Cycle 80 GMT 7/12/2018 19:48:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 20 14.94 520 2 2
2 7 2014.88 41 14.38 3146 2 2
3 13 1891.92 24 14.30 3040 2 3
4 13 1266.88 24 14.42 2186 2 2
5 13 194.44 24 14.88 713 2 3
6 13 49.72 24 14.95 502 2 3
7 8 0.08 150 14.92 405 2 3

Cycle 79 GMT 27/11/2018 19:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 20 14.94 514 2 2
2 7 2005.88 41 14.38 3113 2 2
3 13 1594.32 24 14.38 2617 2 3
4 13 861.92 24 14.59 1638 2 2
5 13 135.12 24 14.91 619 2 2
6 13 36.92 24 14.95 471 2 2
7 8 -0.04 150 14.92 394 2 7

Cycle 78 GMT 17/11/2018 19:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 20 14.93 480 2 2
2 7 2002.32 41 14.39 3086 2 2
3 13 1722.00 24 14.34 2804 2 2
4 13 841.72 24 14.61 1587 2 2
5 13 243.36 24 14.87 742 2 3
6 13 48.72 24 14.95 451 2 2
7 8 0.04 150 14.93 377 2 5

Cycle 77 GMT 7/11/2018 19: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 19 14.95 476 2 2
2 3 1030.36 1 15.11 1894 2 2
3 7 2001.56 41 14.37 3125 2 2
4 13 1590.20 24 14.39 2573 2 3
5 13 736.36 24 14.66 1422 2 2
6 13 132.08 24 14.91 570 2 2
7 13 67.20 24 14.94 473 2 2
8 13 14.36 24 14.96 385 2 2
9 8 -0.20 150 14.91 347 2 7

Cycle 76 GMT 28/10/2018 18: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 19 14.93 482 2 2
2 7 2004.44 41 14.38 3123 2 2
3 13 1607.96 24 14.38 2616 2 3
4 13 1003.28 24 14.53 1793 2 2
5 13 136.76 24 14.93 583 2 2
6 13 68.52 24 14.95 475 2 2
7 13 17.32 24 14.97 390 2 2
8 8 -0.04 150 14.92 355 2 5

Cycle 75 GMT 18/10/2018 17:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 19 14.95 487 2 2
2 7 2007.40 41 14.41 3087 2 2
3 13 1588.64 24 14.40 2559 2 3
4 13 1023.92 24 14.53 1821 2 3
5 13 255.60 24 14.86 772 2 3
6 13 54.08 24 14.95 472 2 2
7 13 28.28 24 14.95 428 2 2
8 8 -0.04 150 14.91 369 2 6

Cycle 74 GMT 8/10/2018 17:30: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 19 14.94 477 2 2
2 7 2004.72 42 14.39 3097 2 2
3 13 1612.08 24 14.38 2655 2 2
4 13 1178.64 24 14.46 2062 2 2
5 13 233.04 24 14.87 736 2 2
6 13 62.64 24 14.95 479 2 2
7 13 33.76 24 14.96 419 2 2
8 8 0.04 150 14.93 364 2 5

Cycle 73 GMT 28/ 9/2018 16:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 19 14.95 493 2 2
2 7 2005.60 42 14.40 3129 2 2
3 13 1612.40 24 14.38 2662 2 2
4 13 1017.96 24 14.53 1833 2 2
5 13 241.28 24 14.87 745 2 2
6 13 54.36 24 14.95 475 2 2
7 13 31.04 24 14.95 430 2 2
8 8 0.00 150 14.92 367 2 5

Cycle 72 GMT 18/ 9/2018 16:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 19 14.95 502 2 2
2 7 2004.76 41 14.41 3079 2 2
3 13 1742.92 24 14.36 2792 2 2
4 13 1006.92 24 14.56 1793 2 2
5 13 261.44 24 14.88 760 2 2
6 13 61.16 24 14.96 488 2 2
7 13 32.20 24 14.96 434 2 2
8 8 0.00 150 14.93 378 2 4

Cycle 71 GMT 8/ 9/2018 15:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 19 14.99 463 2 2
2 7 2002.72 41 14.41 3080 2 2
3 13 1582.96 24 14.41 2544 2 2
4 13 846.16 24 14.63 1552 2 3
5 13 132.96 24 14.94 587 2 2
6 13 67.28 24 14.96 485 2 2
7 13 16.20 24 14.97 390 2 2
8 8 -0.08 150 14.92 369 2 5

Cycle 70 GMT 29/ 8/2018 15:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 19 14.98 472 2 2
2 3 1026.04 1 15.17 1904 2 2
3 7 2001.36 41 14.41 3072 2 2
4 13 1590.20 24 14.41 2582 2 3
5 13 857.76 24 14.62 1611 2 2
6 13 146.48 24 14.94 611 2 2
7 13 45.04 24 14.99 435 2 2
8 8 0.12 150 14.97 345 2 3

Cycle 69 GMT 19/ 8/2018 14:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 20 14.99 472 2 2
2 3 973.60 -1 15.47 1 2 2
3 7 2019.52 41 14.40 3118 2 2
4 13 1635.68 24 14.41 2589 2 3
5 13 782.44 24 14.67 1443 2 2
6 13 208.92 24 14.91 666 2 2
7 13 54.44 24 14.99 429 2 2
8 13 30.52 24 14.99 386 2 2
9 8 0.00 150 14.95 339 2 4

Cycle 68 GMT 9/ 8/2018 13:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 19 14.98 514 2 2
2 3 1023.40 1 15.13 1938 2 2
3 7 1041.20 41 14.86 1841 2 2
4 13 965.00 24 14.81 1701 2 2
5 13 570.72 24 14.84 1176 2 2
6 13 84.40 24 15.01 478 2 2
7 13 48.92 24 15.01 425 2 2
8 8 0.04 150 14.98 345 2 5

Cycle 67 GMT 30/ 7/2018 14:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 20 14.99 495 2 2
2 7 2003.28 41 14.42 3135 2 2
3 13 1584.24 24 14.43 2575 2 2
4 13 850.04 24 14.65 1579 2 2
5 13 243.28 24 14.91 728 2 3
6 13 59.88 24 14.99 454 2 2
7 8 0.00 150 14.97 370 2 3

Cycle 66 GMT 20/ 7/2018 14:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 19 15.01 479 2 2
2 7 2001.44 42 14.42 3081 2 2
3 13 1874.92 24 14.35 2997 2 2
4 13 963.12 24 14.61 1726 2 2
5 13 189.64 24 14.94 661 2 2
6 13 55.16 24 15.01 452 2 2
7 13 15.04 24 15.02 388 2 2
8 8 0.08 150 14.97 354 2 4

Cycle 65 GMT 10/ 7/2018 13:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 20 15.02 469 2 2
2 7 2003.64 42 14.43 3103 2 2
3 13 1728.20 24 14.41 2766 2 2
4 13 830.40 24 14.67 1543 2 2
5 13 131.64 24 14.98 576 2 2
6 13 70.64 24 15.00 472 2 2
7 8 -0.04 150 15.00 337 2 4

Cycle 64 GMT 30/ 6/2018 13:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 20 15.01 474 2 2
2 7 2005.24 42 14.43 3070 2 2
3 13 1876.96 24 14.38 2931 2 2
4 13 1098.48 24 14.57 1899 2 2
5 13 187.24 24 14.96 649 2 2
6 13 97.40 24 14.99 506 2 2
7 13 22.68 24 15.03 369 2 2
8 8 -0.16 150 15.00 319 2 6

Cycle 63 GMT 20/ 6/2018 13:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 19 15.03 479 2 2
2 7 2005.76 41 14.44 3074 2 2
3 13 1582.36 24 14.45 2572 2 2
4 13 727.20 24 14.73 1413 2 2
5 13 152.88 24 14.97 619 2 2
6 13 83.36 24 15.00 498 2 2
7 13 19.92 24 15.03 380 2 2
8 8 0.00 150 14.99 333 2 4

Cycle 62 GMT 10/ 6/2018 13:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 20 15.01 496 2 2
2 7 1919.56 41 14.46 3002 2 2
3 13 1646.24 24 14.44 2638 2 2
4 13 918.40 24 14.65 1666 2 2
5 13 167.44 24 14.97 642 2 2
6 13 52.20 24 15.03 438 2 2
7 8 -0.04 150 15.01 355 2 3

Cycle 61 GMT 31/ 5/2018 12: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 20 15.04 483 2 2
2 7 2005.04 41 14.45 3067 2 2
3 13 1438.36 24 14.51 2370 2 2
4 13 853.88 24 14.68 1576 2 2
5 13 231.48 24 14.94 712 2 2
6 13 67.08 24 15.03 449 2 2
7 13 36.28 24 15.03 396 2 2
8 8 -0.04 150 15.00 351 2 4

Cycle 60 GMT 21/ 5/2018 11:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 20 15.05 467 2 2
2 7 2003.96 42 14.45 3076 2 2
3 13 1443.28 33 14.49 2310 2 2
4 13 588.84 33 14.81 1161 2 2
5 13 74.36 33 15.03 449 2 2
6 8 0.08 150 15.03 335 2 3

Cycle 59 GMT 11/ 5/2018 11:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 20 15.06 461 2 2
2 7 2006.40 42 14.45 3079 2 2
3 13 1605.68 33 14.45 2536 2 2
4 13 545.12 33 14.83 1115 2 2
5 13 106.28 33 15.02 502 2 2
6 8 0.08 150 15.04 334 2 3

Cycle 58 GMT 1/ 5/2018 11:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 20 15.07 458 2 2
2 7 2002.60 42 14.46 3057 2 2
3 13 1738.00 33 14.41 2700 2 2
4 13 567.60 33 14.84 1108 2 2
5 13 105.84 33 15.04 456 2 2
6 8 0.08 150 15.05 312 2 3

Cycle 57 GMT 21/ 4/2018 10:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 19 15.08 448 2 2
2 7 2003.32 41 14.47 3059 2 2
3 13 1734.36 33 14.42 2695 2 2
4 13 519.44 33 14.87 1063 2 2
5 13 109.92 33 15.04 495 2 2
6 8 0.04 150 15.06 311 2 4

Cycle 56 GMT 11/ 4/2018 10:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 18 15.10 435 2 2
2 3 1046.56 1 15.13 1842 2 2
3 7 2004.80 41 14.47 3039 2 2
4 13 1724.40 33 14.43 2686 2 2
5 13 648.12 33 14.81 1247 2 2
6 13 96.20 33 15.06 471 2 2
7 8 0.08 150 15.07 305 2 3

Cycle 55 GMT 1/ 4/2018 10:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 19 15.09 431 2 2
2 3 972.36 -1 15.50 1 2 2
3 7 2003.12 41 14.49 3009 2 2
4 13 1589.56 33 14.48 2506 2 2
5 13 404.96 33 14.93 928 2 2
6 13 80.60 33 15.08 439 2 2
7 8 0.04 150 15.08 301 2 2

Cycle 54 GMT 22/ 3/2018 10:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 19 15.09 471 2 2
2 7 2004.36 42 14.48 3036 2 2
3 13 1872.16 33 14.39 2898 2 2
4 13 762.48 33 14.77 1413 2 2
5 13 98.68 33 15.08 467 2 2
6 8 0.08 150 15.09 307 2 2

Cycle 53 GMT 12/ 3/2018 9:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 19 15.10 405 2 2
2 7 2005.24 42 14.48 3033 2 2
3 13 1600.04 33 14.49 2516 2 2
4 13 532.20 33 14.89 1038 2 2
5 13 79.00 33 15.10 387 2 2
6 8 0.00 150 15.08 308 2 3

Cycle 52 GMT 2/ 3/2018 9:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 19 15.12 403 2 2
2 3 1021.16 1 15.21 1836 2 2
3 7 2008.80 41 14.48 3094 2 2
4 13 1600.52 33 14.49 2524 2 2
5 13 560.76 33 14.88 1072 2 2
6 13 111.52 33 15.07 440 2 2
7 13 24.40 33 15.11 290 2 2
8 8 0.00 150 15.09 252 2 5

Cycle 51 GMT 20/ 2/2018 8:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 19 15.12 387 2 2
2 3 956.88 -1 15.50 1 2 2
3 7 2003.08 42 14.48 3034 2 2
4 13 1732.24 33 14.45 2685 2 2
5 13 619.68 33 14.86 1156 2 2
6 13 83.72 33 15.10 388 2 2
7 8 -0.04 150 15.11 249 2 3

Cycle 50 GMT 10/ 2/2018 8: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 18 15.14 404 2 2
2 3 1034.12 1 15.18 1838 2 2
3 3 1021.68 1 15.23 1842 2 2
4 7 2003.00 41 14.50 3047 2 2
5 13 1591.12 33 14.51 2500 2 2
6 13 696.36 33 14.83 1268 2 2
7 13 98.76 33 15.09 421 2 2
8 8 0.00 150 15.12 253 2 3

Cycle 49 GMT 31/ 1/2018 7:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 18 15.12 386 2 2
2 7 2006.56 42 14.50 3048 2 2
3 13 1875.80 33 14.43 2861 2 2
4 13 601.64 33 14.88 1138 2 2
5 13 90.60 33 15.11 401 2 2
6 8 -0.08 150 15.13 250 2 2

Cycle 48 GMT 21/ 1/2018 7:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 19 15.14 390 2 2
2 3 960.92 -1 15.51 1 2 2
3 7 2001.44 41 14.50 3024 2 2
4 13 1574.72 33 14.52 2487 2 2
5 13 780.88 33 14.79 1385 2 2
6 13 120.52 33 15.08 461 2 2
7 8 0.08 150 15.12 251 2 3

Cycle 47 GMT 11/ 1/2018 7:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 19 15.15 406 2 2
2 7 2008.28 41 14.49 3061 2 2
3 13 1741.24 33 14.47 2695 2 2
4 13 637.88 33 14.87 1182 2 2
5 13 91.48 33 15.12 399 2 2
6 8 0.08 150 15.14 245 2 2

Cycle 46 GMT 1/ 1/2018 6:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 19 15.15 389 2 2
2 7 2002.68 42 14.50 3072 2 2
3 13 1729.76 33 14.48 2685 2 2
4 13 501.48 33 14.94 994 2 2
5 13 105.92 33 15.11 436 2 2
6 8 0.20 150 15.14 249 2 3

Cycle 45 GMT 22/12/2017 6:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 19 15.16 394 2 2
2 7 2001.92 41 14.51 3015 2 2
3 13 1585.36 33 14.54 2497 2 2
4 13 501.80 33 14.95 1002 2 2
5 13 99.84 33 15.12 420 2 2
6 8 0.04 150 15.14 249 2 3

Cycle 44 GMT 12/12/2017 6: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 19 15.16 389 2 2
2 7 2005.44 42 14.50 3084 2 2
3 13 1736.96 33 14.49 2703 2 2
4 13 666.84 33 14.88 1223 2 2
5 13 91.52 33 15.12 409 2 2
6 8 0.16 150 15.14 251 2 3

Cycle 43 GMT 2/12/2017 5:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 19 15.16 394 2 2
2 7 2005.80 41 14.53 3046 2 2
3 13 1450.80 33 14.60 2319 2 2
4 13 556.00 33 14.93 1071 2 2
5 13 108.28 33 15.11 442 2 2
6 8 0.04 150 15.14 252 2 3

Cycle 42 GMT 22/11/2017 5:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 19 15.16 397 2 2
2 7 2003.32 41 14.52 3035 2 2
3 13 1594.36 33 14.55 2513 2 2
4 13 541.44 33 14.94 1057 2 2
5 13 101.60 33 15.12 437 2 2
6 8 0.04 150 15.15 254 2 3

Cycle 41 GMT 12/11/2017 4:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 19 15.17 388 2 2
2 7 2001.96 41 14.52 3070 2 2
3 13 1723.04 33 14.51 2669 2 2
4 13 666.92 33 14.89 1230 2 2
5 13 92.36 33 15.13 414 2 2
6 8 0.04 150 15.15 256 2 3

Cycle 40 GMT 2/11/2017 4:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 19 15.17 394 2 2
2 3 1036.32 1 15.18 1827 2 2
3 7 2002.24 41 14.52 3044 2 2
4 13 1576.80 33 14.56 2486 2 2
5 13 785.64 33 14.83 1401 2 2
6 13 86.76 33 15.15 394 2 2
7 8 0.16 150 15.16 249 2 3

Cycle 39 GMT 23/10/2017 4:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 19 15.16 390 2 2
2 3 965.40 -1 15.54 1 2 2
3 7 2007.20 42 14.52 3042 2 2
4 13 1576.00 33 14.57 2488 2 2
5 13 512.96 33 14.96 1009 2 2
6 13 104.04 33 15.14 430 2 2
7 8 0.16 150 15.16 251 2 3

Cycle 38 GMT 13/10/2017 3:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 19 15.18 403 2 2
2 7 2002.32 42 14.53 3035 2 2
3 13 1589.32 33 14.56 2508 2 2
4 13 539.04 33 14.95 1049 2 2
5 13 97.28 33 15.13 429 2 2
6 13 27.16 33 15.16 299 2 2
7 8 -0.12 150 15.14 253 2 4

Cycle 37 GMT 3/10/2017 3: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 19 15.19 400 2 2
2 7 2001.84 41 14.54 3031 2 2
3 13 1587.60 33 14.57 2506 2 2
4 13 653.40 33 14.91 1207 2 2
5 13 98.04 33 15.14 425 2 2
6 8 0.04 150 15.17 254 2 3

Cycle 36 GMT 23/ 9/2017 2:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 19 15.18 393 2 2
2 7 2000.52 41 14.55 3015 2 2
3 13 1730.24 33 14.53 2693 2 2
4 13 765.32 33 14.86 1361 2 2
5 13 91.32 33 15.16 401 2 2
6 8 0.08 150 15.18 251 2 3

Cycle 35 GMT 13/ 9/2017 2: 2: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 19 15.18 406 2 2
2 7 2012.08 41 14.53 3060 2 2
3 13 1880.48 33 14.48 2913 2 2
4 13 737.64 33 14.88 1324 2 2
5 13 109.52 33 15.14 442 2 2
6 8 0.08 150 15.17 250 2 3

Cycle 34 GMT 3/ 9/2017 1:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 19 15.19 399 2 2
2 7 2001.92 41 14.54 3035 2 2
3 13 1451.48 33 14.63 2313 2 2
4 13 702.36 33 14.89 1276 2 2
5 13 107.32 33 15.15 441 2 2
6 8 0.08 150 15.17 255 2 4

Cycle 33 GMT 24/ 8/2017 1:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 19 15.19 402 2 2
2 7 2004.16 41 14.55 3051 2 2
3 13 1738.96 33 14.55 2693 2 2
4 13 661.72 33 14.92 1223 2 2
5 13 92.56 33 15.17 409 2 2
6 8 0.12 150 15.19 254 2 2

Cycle 32 GMT 14/ 8/2017 1: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 19 15.20 385 2 2
2 7 2001.40 41 14.56 3029 2 2
3 13 1570.48 33 14.60 2478 2 2
4 13 537.28 33 14.98 1051 2 2
5 13 104.04 33 15.15 435 2 2
6 8 0.04 150 15.18 253 2 3

Cycle 31 GMT 4/ 8/2017 0:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 19 15.19 396 2 2
2 7 2001.32 41 14.55 3024 2 2
3 13 1597.88 33 14.59 2501 2 2
4 13 557.52 33 14.97 1077 2 2
5 13 112.08 33 15.16 439 2 2
6 8 0.16 150 15.19 251 2 3

Cycle 30 GMT 25/ 7/2017 0:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 19 15.18 401 2 2
2 7 2001.20 41 14.56 3022 2 2
3 13 1607.08 33 14.60 2522 2 2
4 13 807.08 33 14.85 1433 2 2
5 13 123.52 33 15.15 468 2 2
6 8 0.04 150 15.18 255 2 3

Cycle 29 GMT 15/ 7/2017 0:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 19 15.20 399 2 2
2 7 2004.44 41 14.56 3034 2 2
3 13 1604.24 33 14.59 2523 2 2
4 13 548.44 33 14.97 1064 2 2
5 13 112.72 33 15.16 448 2 2
6 13 62.24 33 15.17 357 2 2
7 8 -0.04 150 15.17 255 2 7

Cycle 28 GMT 4/ 7/2017 23:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 19 15.21 394 2 2
2 7 2017.48 42 14.55 3041 2 2
3 13 1620.48 33 14.59 2545 2 2
4 13 531.72 33 14.99 1039 2 2
5 13 104.40 33 15.16 433 2 2
6 8 0.12 150 15.19 254 2 3

Cycle 27 GMT 24/ 6/2017 22:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 19 15.20 402 2 2
2 7 2001.76 41 14.57 3044 2 2
3 13 1580.84 47 14.58 2482 2 2
4 13 226.32 47 15.11 620 2 2
5 8 0.08 150 15.20 249 2 2

Cycle 26 GMT 14/ 6/2017 22:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 19 15.21 407 2 2
2 7 2009.20 41 14.57 3048 2 2
3 13 1883.24 47 14.47 2875 2 2
4 13 227.60 47 15.12 622 2 2
5 13 20.04 47 15.21 278 2 2
6 8 -0.04 150 15.18 253 2 5

Cycle 25 GMT 4/ 6/2017 22:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 19 15.22 398 2 2
2 7 2003.24 41 14.58 3039 2 2
3 13 1568.68 47 14.59 2462 2 2
4 13 273.04 47 15.10 683 2 2
5 8 0.04 150 15.21 251 2 2

Cycle 24 GMT 25/ 5/2017 21:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 18 15.20 393 2 2
2 3 1036.60 1 15.22 1822 2 2
3 3 1020.36 1 15.30 1823 2 2
4 7 2004.20 42 14.58 3038 2 2
5 13 1881.88 47 14.49 2859 2 2
6 13 206.36 47 15.14 596 2 2
7 8 0.08 150 15.22 251 2 4

Cycle 23 GMT 15/ 5/2017 20:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 19 15.20 385 2 2
2 3 972.40 -1 15.56 1 2 2
3 7 2003.80 41 14.58 3061 2 2
4 13 1464.52 47 14.63 2320 2 2
5 13 206.20 47 15.13 593 2 2
6 13 38.00 47 15.20 314 2 2
7 8 -0.04 150 15.19 254 2 5

Cycle 22 GMT 5/ 5/2017 20: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 19 15.21 401 2 2
2 7 2003.60 36 14.62 3036 2 2
3 13 1884.44 47 14.52 2862 2 2
4 13 405.12 47 15.05 864 2 2
5 13 23.92 47 15.22 289 2 2
6 8 0.04 150 15.20 253 2 5

Cycle 21 GMT 25/ 4/2017 20: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 19 15.20 414 2 2
2 3 970.00 -1 15.57 1 2 2
3 3 1047.80 1 15.21 1844 2 2
4 7 2002.20 36 14.62 3048 2 2
5 13 1730.64 47 14.56 2672 2 2
6 13 272.64 47 15.11 688 2 2
7 13 26.68 47 15.22 296 2 2
8 8 0.04 150 15.20 257 2 4

Cycle 20 GMT 15/ 4/2017 19:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 19 15.23 400 2 2
2 7 2005.56 36 14.62 3057 2 2
3 13 1880.20 47 14.52 2863 2 2
4 13 543.04 47 14.98 1055 2 2
5 13 73.12 47 15.18 382 2 2
6 8 0.04 150 15.18 264 2 6

Cycle 19 GMT 5/ 4/2017 19: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 19 15.23 411 2 2
2 7 2004.84 36 14.63 3048 2 2
3 13 1883.52 47 14.52 2871 2 2
4 13 385.68 47 15.06 843 2 2
5 8 0.00 150 15.22 254 2 2

Cycle 18 GMT 26/ 3/2017 18:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 19 15.23 403 2 2
2 7 1997.72 36 14.63 3017 2 2
3 13 1730.44 33 14.61 2708 2 2
4 13 683.92 33 14.96 1248 2 2
5 13 102.48 33 15.20 430 2 2
6 8 0.16 150 15.23 254 2 5

Cycle 17 GMT 16/ 3/2017 17:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 19 15.24 406 2 2
2 7 2002.68 39 14.62 3039 2 2
3 13 1562.60 33 14.67 2464 2 2
4 13 646.76 33 14.97 1198 2 2
5 13 86.60 33 15.21 406 2 2
6 8 0.08 150 15.23 256 2 3

Cycle 16 GMT 6/ 3/2017 17:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 19 15.22 394 2 2
2 7 2003.08 38 14.63 3036 2 2
3 13 1476.12 33 14.70 2356 2 2
4 13 591.64 33 15.00 1131 2 2
5 13 91.68 33 15.22 407 2 2
6 8 0.00 150 15.23 257 2 2

Cycle 15 GMT 24/ 2/2017 16:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 19 15.24 403 2 2
2 7 2001.92 38 14.63 3042 2 2
3 13 1589.60 33 14.66 2499 2 2
4 13 978.64 33 14.83 1663 2 2
5 13 118.08 33 15.19 463 2 2
6 8 0.00 150 15.23 259 2 3

Cycle 14 GMT 14/ 2/2017 16:25: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 19 15.23 390 2 2
2 7 1993.68 38 14.65 3011 2 2
3 13 1866.56 33 14.60 2869 2 2
4 13 777.12 33 14.93 1394 2 2
5 13 85.60 33 15.23 398 2 2
6 8 0.08 150 15.24 255 2 3

Cycle 13 GMT 4/ 2/2017 15:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 19 15.24 392 2 2
2 7 2003.20 33 14.67 3100 2 2
3 13 1871.32 33 14.61 2887 2 2
4 13 814.88 33 14.92 1442 2 2
5 13 85.72 33 15.23 403 2 2
6 8 0.08 150 15.23 258 2 2

Cycle 12 GMT 25/ 1/2017 14:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 19 15.24 400 2 2
2 7 2003.64 33 14.67 3048 2 2
3 13 1633.00 33 14.67 2557 2 2
4 13 621.20 33 15.00 1162 2 2
5 13 88.16 33 15.23 408 2 2
6 8 0.08 150 15.24 255 2 2

Cycle 11 GMT 15/ 1/2017 13:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 19 15.24 412 2 2
2 3 1025.00 1 15.29 1829 2 2
3 7 1999.00 33 14.68 3061 2 2
4 13 1624.88 33 14.68 2552 2 2
5 13 748.32 33 14.94 1344 2 2
6 13 74.04 33 15.24 382 2 2
7 8 0.00 150 15.24 256 2 2

Cycle 10 GMT 5/ 1/2017 11:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 19 15.25 394 2 2
2 7 2001.64 33 14.69 3046 2 2
3 13 1635.88 33 14.67 2577 2 2
4 13 502.76 33 15.05 1005 2 2
5 13 100.40 33 15.22 431 2 2
6 8 0.08 150 15.24 257 2 3

Cycle 9 GMT 26/12/2016 10:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 19 15.26 398 2 2
2 7 2001.04 32 14.70 3069 2 2
3 13 1880.32 26 14.65 2898 2 2
4 13 774.00 26 14.96 1392 2 2
5 13 134.56 26 15.22 493 2 2
6 13 76.88 26 15.24 387 2 2
7 8 0.00 150 15.25 258 2 3

Cycle 8 GMT 16/12/2016 9:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 18 15.25 400 2 2
2 3 1052.36 1 15.22 1832 2 2
3 7 2001.44 31 14.71 3065 2 2
4 13 1882.36 26 14.65 2890 2 2
5 13 1014.32 26 14.87 1718 2 2
6 13 174.84 26 15.20 555 2 2
7 13 58.16 26 15.26 349 2 2
8 8 0.12 150 15.25 253 2 3

Cycle 7 GMT 6/12/2016 7:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 19 15.27 382 2 2
2 3 966.44 -1 15.60 1 2 2
3 7 1981.40 30 14.74 3026 2 2
4 13 1863.60 26 14.67 2863 2 2
5 13 1134.48 26 14.82 1875 2 2
6 13 148.40 26 15.21 509 2 2
7 13 77.88 26 15.24 384 2 2
8 8 -0.12 150 15.25 253 2 2

Cycle 6 GMT 26/11/2016 6:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 18 15.26 393 2 2
2 3 1049.48 1 15.24 1842 2 2
3 7 1995.52 46 14.64 3004 2 2
4 13 1207.80 26 14.82 1971 2 2
5 13 283.84 26 15.16 700 2 2
6 13 88.16 26 15.25 399 2 2
7 8 0.04 190 15.25 249 2 2

Cycle 5 GMT 16/11/2016 4:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 24 15.27 396 2 2
2 3 769.04 -4 15.62 2 2 2
3 3 930.28 -1 15.63 1 2 2
4 7 1992.20 45 14.66 2991 2 2
5 13 1284.52 26 14.80 2070 2 2
6 13 463.64 26 15.08 946 2 2
7 13 97.24 26 15.24 419 2 2
8 13 23.68 26 15.27 287 2 2
9 8 -0.04 190 15.24 253 2 3

Cycle 4 GMT 6/11/2016 2:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 19 15.28 398 2 2
2 7 1510.80 45 14.88 2415 2 2
3 13 1148.28 26 14.91 1896 2 2
4 13 207.36 26 15.21 604 2 2
5 13 68.92 26 15.27 367 2 2
6 8 0.08 190 15.26 256 2 2

Cycle 3 GMT 5/11/2016 2:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 19 15.28 401 2 2
2 7 1514.88 46 14.87 2421 2 2
3 13 1252.92 26 14.87 2056 2 2
4 13 160.76 26 15.23 539 2 2
5 13 88.96 26 15.26 410 2 2
6 8 0.04 190 15.26 257 2 2

Cycle 2 GMT 4/11/2016 3:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 24 15.27 398 2 2
2 3 797.92 -4 15.61 1 2 2
3 3 962.24 -1 15.63 1 2 2
4 7 1526.00 45 14.87 2438 2 2
5 13 1151.16 26 14.89 1907 2 2
6 13 194.12 26 15.21 598 2 2
7 13 66.48 26 15.27 372 2 2
8 8 0.08 190 15.26 257 2 2

Cycle 1 GMT 3/11/2016 3:30:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 24 15.38 387 2 2
2 3 810.68 -4 15.58 1 2 2
3 3 973.16 -1 15.60 1 2 2
4 7 1002.44 74 14.97 1705 2 2
5 13 57.88 25 15.30 363 2 3
6 8 0.00 237 15.26 261 2 244

Cycle 0 GMT 2/11/2016 16: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 139.40 24 15.59 450 2 2
2 7 149.04 74 15.53 460 2 2
3 13 28.84 25 15.51 281 2 2
4 8 0.04 223 15.45 230 2 243