SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8010 WMO= 5903526


Cycle 30 GMT 2/11/2011 7: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.44 33 14.37 500 7
2 114.16 -18 14.37 500 7
3 351.76 -13 14.37 500 7
4 600.08 68 13.06 1303 6
5 58.52 25 14.23 532 7 7
6 0.08 25 14.33 478 7 7
7 0.08 258 13.92 425 7

Cycle 29 GMT 23/10/2011 8:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.68 34 14.31 538 8 189
2 971.36 -1 14.31 538 8 189
3 2009.36 68 12.09 2963 189 6
4 1570.12 25 12.90 2466 6 6
5 878.88 25 13.37 1657 6 6
6 197.72 24 14.03 765 7 7
7 48.00 24 14.30 528 7 7
8 -0.00 295 13.96 423 7

Cycle 28 GMT 13/10/2011 8:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.68 34 14.25 576 7
2 2000.64 81 12.10 2952 6
3 1497.00 25 12.97 2395 6 6
4 771.24 25 13.47 1528 6 6
5 129.80 24 14.16 653 6 7
6 59.08 24 14.21 570 7 7
7 0.12 25 14.42 412 7 7
8 0.08 258 13.96 405 8 189

Cycle 27 GMT 3/10/2011 9: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 34 14.31 596 7
2 2002.80 81 12.07 3098 6
3 1299.76 25 13.08 2245 6 6
4 839.00 25 13.43 1641 6 6
5 91.08 25 14.19 655 7 7
6 43.64 25 14.30 476 7 7
7 0.16 284 13.95 425 7

Cycle 26 GMT 23/ 9/2011 8:59: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.40 34 14.31 596 16
2 2003.24 81 12.10 3082 6
3 1276.20 25 13.13 2230 6 6
4 592.96 25 13.63 1353 6 6
5 102.44 25 14.21 638 7 7
6 49.00 25 14.30 522 7 7
7 0.16 25 14.45 451 7 7
8 0.12 252 14.06 392 7

Cycle 25 GMT 13/ 9/2011 8:37: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 34 14.37 500 7
2 2000.96 81 12.15 3100 6
3 1307.40 25 13.15 2226 6 6
4 625.60 25 13.63 1399 6 6
5 93.28 25 14.24 628 7 7
6 44.56 25 14.31 505 7 7
7 0.04 25 14.38 445 7 7
8 0.08 255 13.99 416 16

Cycle 24 GMT 3/ 9/2011 8:33:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 34 14.37 500 7
2 2007.52 81 12.15 3097 6
3 1087.48 25 13.30 1978 6 6
4 621.36 25 13.69 1347 6 6
5 91.64 24 14.27 593 7 7
6 43.28 24 14.31 513 7 7
7 0.12 279 14.04 418 7

Cycle 23 GMT 24/ 8/2011 8:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.68 34 14.37 500 7
2 2000.96 81 12.18 3080 6
3 1312.56 25 13.22 2241 6 6
4 607.52 25 13.69 1351 6 6
5 102.96 25 14.29 597 7 7
6 25.56 25 14.41 470 7 7
7 0.12 25 14.43 412 7 8
8 0.04 252 14.06 404 7

Cycle 22 GMT 14/ 8/2011 8:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.80 34 14.31 538 7
2 2003.76 81 12.26 2971 6
3 1082.16 25 13.32 1995 6 6
4 422.60 25 13.88 1093 6 6
5 91.44 25 14.26 634 7 7
6 45.48 25 14.32 486 7 7
7 0.16 25 14.37 470 7 9
8 0.16 247 14.04 394 7

Cycle 21 GMT 4/ 8/2011 8: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.28 34 14.31 538 7
2 2000.76 81 12.24 3080 6
3 1275.12 25 13.25 2163 6 6
4 590.76 25 13.69 1355 6 6
5 82.88 25 14.28 603 7 7
6 39.72 25 14.29 514 7 7
7 0.04 25 14.40 447 7 8
8 -0.04 250 14.00 412 7

Cycle 20 GMT 25/ 7/2011 8: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.72 34 14.37 538 7
2 2007.00 81 12.22 3111 6
3 1288.36 25 13.24 2240 6 6
4 594.72 25 13.72 1357 6 6
5 99.72 25 14.25 645 7 7
6 47.76 25 14.32 530 7 7
7 0.04 25 14.40 470 7 8
8 0.08 252 14.04 411 7

Cycle 19 GMT 15/ 7/2011 7:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.60 34 14.37 519 7
2 2002.48 81 12.25 3080 6
3 1291.40 25 13.21 2257 6 6
4 582.12 25 13.72 1343 6 6
5 98.36 25 14.31 601 7 7
6 9.72 25 14.47 451 7 7
7 0.12 25 14.41 420 7 7
8 -0.00 250 14.08 406 7

Cycle 18 GMT 5/ 7/2011 7:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.80 34 14.37 519 7
2 2001.24 81 12.26 3074 6
3 1293.56 25 13.21 2265 6 6
4 604.36 25 13.72 1330 6 6
5 89.08 25 14.30 585 7 7
6 44.00 25 14.33 503 7 7
7 0.20 25 14.43 432 7 7
8 0.16 250 14.04 405 7

Cycle 17 GMT 25/ 6/2011 7:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.68 34 14.37 519 7
2 2002.12 81 12.24 3075 6
3 1304.56 25 13.21 2265 6 6
4 612.44 25 13.70 1366 6 6
5 93.32 25 14.28 626 7 7
6 45.08 25 14.32 530 7 7
7 0.12 25 14.42 445 7 7
8 0.04 250 14.06 404 7

Cycle 16 GMT 15/ 6/2011 7:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.04 33 14.37 500 7
2 2004.60 81 12.26 3044 6
3 1288.00 25 13.23 2216 6 6
4 576.36 25 13.75 1291 6 6
5 98.88 25 14.28 616 7 7
6 47.48 25 14.35 519 7 7
7 0.12 25 14.45 440 7 9
8 -0.00 250 14.08 403 7

Cycle 15 GMT 5/ 6/2011 7: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 33 14.43 519 7
2 2000.64 81 12.26 3074 6
3 1075.20 25 13.36 1970 6 6
4 625.52 25 13.71 1385 6 6
5 93.52 25 14.28 622 7 7
6 46.92 25 14.35 513 7 7
7 0.24 274 14.09 415 7

Cycle 14 GMT 26/ 5/2011 6:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 33 14.43 500 7
2 2005.16 81 12.26 3069 6
3 1274.48 25 13.25 2191 6 6
4 563.84 25 13.74 1305 6 6
5 95.84 24 14.30 601 7 7
6 45.20 24 14.38 503 7 7
7 0.88 276 14.11 399 7

Cycle 13 GMT 16/ 5/2011 6:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.04 33 14.37 557 7
2 2004.64 81 12.31 3025 6
3 1255.04 25 13.25 2145 6 6
4 545.52 25 13.77 1243 6 6
5 88.24 25 14.32 582 7 7
6 40.60 25 14.40 485 7 7
7 0.24 25 14.49 426 7 8
8 0.08 247 14.07 402 7

Cycle 12 GMT 6/ 5/2011 5:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 39 14.31 519 7
2 800.88 -4 14.31 519 7
3 894.44 -2 14.31 519 7
4 2009.52 81 12.30 3071 6
5 1090.80 25 13.34 1991 6 6
6 636.24 25 13.70 1382 6 6
7 89.52 24 14.31 597 7 7
8 45.36 24 14.36 524 7 7
9 0.08 25 14.47 436 7 8
10 0.04 252 14.06 404 7

Cycle 11 GMT 26/ 4/2011 4:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.00 32 14.37 538 7
2 2007.72 81 12.34 3048 6
3 1071.36 25 13.34 1947 6 6
4 389.92 25 13.92 1043 6 6
5 89.04 25 14.34 582 7 7
6 0.16 297 14.10 405 7

Cycle 10 GMT 16/ 4/2011 3:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.96 34 14.50 461 7
2 923.44 -3 14.50 461 7
3 2000.56 81 12.39 3008 6
4 1267.84 25 13.24 2182 6 6
5 529.96 25 13.77 1226 6 6
6 69.84 25 14.38 540 7 7
7 14.32 25 14.47 444 7 7
8 0.12 274 14.09 403 7

Cycle 9 GMT 6/ 4/2011 3:15: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.68 39 14.37 519 7
2 730.20 -10 14.37 519 7
3 1995.96 81 12.48 2992 6
4 1262.44 25 13.27 2147 6 6
5 545.20 25 13.77 1253 6 6
6 75.64 25 14.43 555 7 7
7 0.04 25 14.57 428 7 7
8 -0.00 271 14.09 396 7

Cycle 8 GMT 5/ 4/2011 7:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.40 37 14.37 538 7
2 800.00 -7 14.37 538 7
3 1908.12 81 12.55 2920 6
4 1162.80 25 13.29 2062 6 6
5 450.04 25 13.88 1116 6 6
6 92.64 25 14.39 574 7 7
7 1.16 293 14.11 405 7

Cycle 7 GMT 4/ 4/2011 15:30: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.20 31 14.50 480 7
2 1192.56 5 14.06 2192 7
3 1909.32 81 12.55 2924 6
4 980.76 25 13.42 1813 6 6
5 295.28 25 14.09 874 7 7
6 63.28 25 14.45 526 7 7
7 0.08 25 14.57 432 7 7
8 0.08 266 14.08 401 7

Cycle 6 GMT 4/ 4/2011 0: 1: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.40 32 14.43 500 7
2 1225.48 6 14.06 2153 7
3 1712.52 81 12.70 2693 6
4 1003.00 25 13.39 1828 6 6
5 330.60 25 14.04 941 6 7
6 82.80 25 14.41 566 7 7
7 0.84 295 14.13 394 7

Cycle 5 GMT 3/ 4/2011 10:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.20 33 14.43 500 7
2 965.16 -1 14.43 500 7
3 1713.36 81 12.70 2702 6
4 1037.84 25 13.30 1913 6 6
5 581.84 25 13.70 1295 6 6
6 94.40 25 14.37 587 7 7
7 45.36 25 14.43 493 7 7
8 0.04 276 14.11 389 7

Cycle 4 GMT 2/ 4/2011 20:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.76 39 14.31 500 7
2 752.20 -7 14.31 500 7
3 1713.68 81 12.69 2688 6
4 1003.64 25 13.34 1843 6 6
5 291.20 25 14.01 903 6 6
6 60.72 25 14.37 562 7 7
7 0.12 25 14.52 455 7 7
8 0.12 266 14.02 398 7

Cycle 3 GMT 2/ 4/2011 6: 5: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.80 37 14.31 519 7
2 861.72 -8 14.31 519 7
3 1515.96 81 12.80 2466 6
4 626.56 25 13.59 1376 6 6
5 170.96 25 14.13 747 7 7
6 42.96 25 14.38 530 7 7
7 0.08 282 14.02 411 7

Cycle 2 GMT 1/ 4/2011 18:34: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.12 39 14.25 500 7
2 925.12 -4 14.25 500 7
3 1513.64 81 12.75 2451 6
4 851.84 25 13.37 1638 6 6
5 195.52 25 14.09 736 6 7
6 95.64 25 14.22 597 7 7
7 0.28 290 14.04 387 7

Cycle 1 GMT 1/ 4/2011 7:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.40 25 14.50 480 7
2 1115.36 3 13.93 2019 7
3 1110.88 3 13.87 2019 7
4 1028.16 81 12.92 1835 6
5 90.44 25 14.20 570 7 7
6 0.04 295 13.99 400 7

Cycle 0 GMT 31/ 3/2011 20:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 58.20 81 14.18 431 7
2 66.48 25 14.48 438 7 7
3 33.92 25 14.54 399 7 7
4 0.24 25 14.65 353 7 7
5 0.20 256 14.31 329 7