SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 39 | 14.17 | 519 | 12 | 16 |
2 | 2013.12 | 40 | 9.22 | 2900 | 16 | 7 |
3 | 1971.32 | 20 | 12.14 | 2715 | 7 | 6 |
4 | 1894.44 | 20 | 12.19 | 2708 | 6 | 7 |
5 | 1796.52 | 20 | 12.28 | 2619 | 7 | 7 |
6 | 1364.48 | 20 | 12.69 | 2102 | 7 | 7 |
7 | 922.28 | 20 | 13.05 | 1602 | 7 | 8 |
8 | 588.20 | 20 | 13.36 | 1206 | 7 | 9 |
9 | 89.84 | 20 | 13.98 | 566 | 7 | 9 |
10 | 51.12 | 20 | 14.13 | 504 | 7 | 8 |
11 | 1.04 | 165 | 14.12 | 401 | 7 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.12 | 39 | 14.17 | 519 | 8 | 20 |
2 | 2009.20 | 40 | 9.41 | 2752 | 20 | 6 |
3 | 1894.00 | 25 | 11.97 | 2688 | 7 | 7 |
4 | 1747.60 | 25 | 12.18 | 2553 | 7 | 6 |
5 | 1533.92 | 25 | 12.42 | 2286 | 7 | 7 |
6 | 1038.88 | 25 | 12.88 | 1728 | 7 | 7 |
7 | 522.92 | 25 | 13.39 | 1114 | 7 | 10 |
8 | 107.36 | 25 | 13.94 | 586 | 7 | 10 |
9 | 44.56 | 25 | 14.09 | 490 | 7 | 9 |
10 | -0.00 | 25 | 14.25 | 426 | 7 | 9 |
11 | -0.12 | 166 | 14.04 | 402 | 12 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.40 | 39 | 14.10 | 519 | 7 | 20 |
2 | 2011.36 | 40 | 9.37 | 2932 | 20 | 7 |
3 | 1901.60 | 25 | 11.99 | 2720 | 7 | 7 |
4 | 1734.24 | 25 | 12.14 | 2553 | 7 | 7 |
5 | 1511.96 | 25 | 12.43 | 2278 | 7 | 7 |
6 | 1023.72 | 25 | 12.88 | 1713 | 7 | 8 |
7 | 303.08 | 25 | 13.65 | 843 | 7 | 9 |
8 | 72.36 | 25 | 14.03 | 536 | 7 | 9 |
9 | 30.60 | 25 | 14.16 | 468 | 7 | 9 |
10 | 0.04 | 24 | 14.28 | 420 | 7 | 9 |
11 | -0.04 | 165 | 14.08 | 402 | 8 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 39 | 14.10 | 519 | 8 | 17 |
2 | 2009.80 | 40 | 9.41 | 2909 | 17 | 6 |
3 | 1909.44 | 25 | 11.95 | 2743 | 6 | 6 |
4 | 1737.36 | 25 | 12.15 | 2534 | 7 | 7 |
5 | 1505.04 | 25 | 12.43 | 2262 | 7 | 7 |
6 | 1000.40 | 25 | 12.91 | 1676 | 7 | 8 |
7 | 265.40 | 25 | 13.72 | 788 | 7 | 9 |
8 | 107.04 | 25 | 13.96 | 582 | 7 | 10 |
9 | 0.08 | 165 | 14.09 | 402 | 7 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.24 | 39 | 14.10 | 519 | 8 | 13 |
2 | 2004.88 | 40 | 9.38 | 2942 | 13 | 6 |
3 | 1886.68 | 25 | 12.03 | 2684 | 7 | 7 |
4 | 1708.64 | 25 | 12.25 | 2490 | 6 | 7 |
5 | 1491.12 | 25 | 12.43 | 2253 | 7 | 7 |
6 | 1022.16 | 25 | 12.88 | 1712 | 7 | 8 |
7 | 274.40 | 25 | 13.71 | 809 | 7 | 9 |
8 | 67.92 | 25 | 14.07 | 528 | 7 | 8 |
9 | 0.04 | 24 | 14.26 | 428 | 9 | 12 |
10 | 0.04 | 165 | 14.08 | 400 | 8 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.64 | 39 | 14.10 | 519 | 9 | 24 |
2 | 2012.08 | 40 | 9.73 | 2760 | 24 | 7 |
3 | 1905.04 | 25 | 11.99 | 2718 | 7 | 7 |
4 | 1726.96 | 25 | 12.19 | 2497 | 7 | 7 |
5 | 1511.04 | 25 | 12.45 | 2261 | 7 | 7 |
6 | 1020.64 | 25 | 12.88 | 1699 | 7 | 8 |
7 | 283.92 | 25 | 13.67 | 820 | 7 | 9 |
8 | 116.44 | 25 | 13.96 | 607 | 7 | 9 |
9 | 0.04 | 25 | 14.24 | 430 | 7 | 11 |
10 | -0.00 | 166 | 14.05 | 403 | 8 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.36 | 39 | 14.10 | 538 | 8 | 14 |
2 | 2010.48 | 40 | 9.65 | 2889 | 14 | 7 |
3 | 1896.84 | 25 | 11.94 | 2705 | 7 | 7 |
4 | 1714.48 | 25 | 12.20 | 2493 | 7 | 7 |
5 | 1506.80 | 25 | 12.41 | 2253 | 7 | 7 |
6 | 1026.56 | 25 | 12.89 | 1697 | 7 | 8 |
7 | 289.40 | 25 | 13.69 | 809 | 7 | 9 |
8 | 65.04 | 25 | 14.08 | 515 | 7 | 8 |
9 | -0.00 | 25 | 14.25 | 428 | 7 | 10 |
10 | 0.12 | 166 | 14.06 | 402 | 9 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.08 | 39 | 14.17 | 519 | 7 | 15 |
2 | 2001.92 | 40 | 9.88 | 2823 | 15 | 7 |
3 | 1889.92 | 25 | 11.84 | 2738 | 7 | 7 |
4 | 1725.36 | 25 | 12.21 | 2495 | 7 | 7 |
5 | 1516.28 | 25 | 12.37 | 2286 | 7 | 7 |
6 | 1016.24 | 25 | 12.84 | 1726 | 7 | 7 |
7 | 273.84 | 25 | 13.68 | 812 | 7 | 9 |
8 | 111.76 | 25 | 13.96 | 599 | 7 | 9 |
9 | 0.08 | 25 | 14.25 | 434 | 7 | 8 |
10 | 0.04 | 166 | 14.07 | 399 | 8 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 39 | 14.10 | 538 | 10 | 16 |
2 | 2006.60 | 70 | 10.05 | 2749 | 16 | 7 |
3 | 1805.88 | 25 | 12.04 | 2613 | 7 | 7 |
4 | 1597.44 | 25 | 12.29 | 2366 | 7 | 7 |
5 | 897.56 | 25 | 13.01 | 1566 | 7 | 7 |
6 | 423.84 | 25 | 13.50 | 995 | 7 | 9 |
7 | 90.20 | 25 | 14.05 | 559 | 7 | 8 |
8 | 0.12 | 201 | 14.11 | 403 | 7 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 39 | 14.17 | 538 | 8 | 27 |
2 | 2002.44 | 70 | 10.08 | 2786 | 27 | 7 |
3 | 1845.48 | 25 | 12.00 | 2663 | 7 | 7 |
4 | 1425.36 | 25 | 12.46 | 2178 | 7 | 7 |
5 | 754.36 | 25 | 13.11 | 1395 | 7 | 8 |
6 | 293.40 | 25 | 13.66 | 835 | 7 | 9 |
7 | 64.72 | 25 | 14.07 | 528 | 7 | 8 |
8 | 0.12 | 25 | 14.29 | 424 | 7 | 10 |
9 | 0.08 | 200 | 14.08 | 398 | 10 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.48 | 39 | 14.17 | 519 | 7 | 18 |
2 | 2002.68 | 70 | 10.12 | 2791 | 18 | 6 |
3 | 1820.68 | 25 | 12.02 | 2645 | 7 | 7 |
4 | 1382.80 | 25 | 12.53 | 2126 | 7 | 7 |
5 | 914.24 | 25 | 13.00 | 1591 | 7 | 7 |
6 | 213.44 | 25 | 13.79 | 728 | 7 | 9 |
7 | 108.00 | 25 | 13.97 | 591 | 7 | 9 |
8 | 0.20 | 201 | 14.09 | 406 | 8 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.36 | 39 | 14.04 | 557 | 7 | 17 |
2 | 2006.48 | 70 | 10.10 | 2804 | 17 | 7 |
3 | 1825.08 | 25 | 12.05 | 2638 | 7 | 6 |
4 | 1607.92 | 25 | 12.29 | 2378 | 7 | 7 |
5 | 908.20 | 25 | 12.99 | 1583 | 7 | 7 |
6 | 239.08 | 25 | 13.77 | 757 | 7 | 8 |
7 | 118.24 | 25 | 13.98 | 595 | 7 | 8 |
8 | 0.12 | 201 | 14.11 | 398 | 7 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.08 | 39 | 14.10 | 538 | 7 | 17 |
2 | 2005.36 | 70 | 10.26 | 2776 | 17 | 7 |
3 | 1816.76 | 25 | 12.12 | 2582 | 6 | 6 |
4 | 1379.00 | 25 | 12.48 | 2136 | 7 | 7 |
5 | 910.04 | 25 | 12.97 | 1585 | 7 | 8 |
6 | 209.84 | 25 | 13.76 | 736 | 7 | 9 |
7 | 99.12 | 25 | 14.02 | 574 | 7 | 8 |
8 | 0.12 | 201 | 14.10 | 402 | 7 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 39 | 14.04 | 557 | 7 | 22 |
2 | 2001.52 | 70 | 10.15 | 2769 | 22 | 7 |
3 | 1817.72 | 25 | 12.10 | 2614 | 7 | 7 |
4 | 1602.12 | 25 | 12.30 | 2378 | 7 | 7 |
5 | 886.44 | 25 | 13.01 | 1560 | 7 | 7 |
6 | 220.72 | 25 | 13.76 | 745 | 7 | 9 |
7 | 107.56 | 25 | 13.99 | 597 | 7 | 8 |
8 | 1.12 | 200 | 14.07 | 409 | 7 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 39 | 14.10 | 538 | 7 | 20 |
2 | 2011.76 | 70 | 10.09 | 2879 | 20 | 7 |
3 | 1821.80 | 25 | 12.09 | 2609 | 7 | 7 |
4 | 1384.12 | 25 | 12.50 | 2143 | 7 | 7 |
5 | 927.00 | 25 | 12.95 | 1613 | 7 | 7 |
6 | 220.64 | 25 | 13.79 | 734 | 7 | 8 |
7 | 107.32 | 25 | 14.02 | 580 | 7 | 9 |
8 | 0.08 | 25 | 14.25 | 426 | 7 | 8 |
9 | 0.08 | 200 | 14.05 | 397 | 7 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 117.04 | 39 | 14.10 | 519 | 9 | 18 |
2 | 2011.56 | 70 | 10.25 | 2817 | 18 | 7 |
3 | 1837.24 | 25 | 12.12 | 2624 | 7 | 6 |
4 | 1385.12 | 25 | 12.53 | 2124 | 7 | 7 |
5 | 720.20 | 25 | 13.17 | 1366 | 7 | 8 |
6 | 146.56 | 25 | 13.88 | 649 | 7 | 8 |
7 | 86.32 | 25 | 14.07 | 557 | 7 | 8 |
8 | 0.04 | 25 | 14.27 | 430 | 7 | 8 |
9 | 0.08 | 200 | 14.06 | 398 | 7 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.52 | 39 | 14.04 | 538 | 9 | 14 |
2 | 2002.20 | 70 | 10.43 | 2740 | 14 | 7 |
3 | 1822.68 | 25 | 12.11 | 2622 | 7 | 7 |
4 | 1376.12 | 25 | 12.55 | 2116 | 7 | 7 |
5 | 713.56 | 25 | 13.20 | 1335 | 7 | 8 |
6 | 143.36 | 25 | 13.92 | 630 | 7 | 8 |
7 | 79.40 | 25 | 14.08 | 541 | 7 | 8 |
8 | -0.00 | 25 | 14.29 | 418 | 9 | 8 |
9 | 0.04 | 200 | 14.06 | 394 | 9 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.56 | 39 | 14.17 | 519 | 7 | 12 |
2 | 2010.28 | 70 | 10.20 | 2886 | 12 | 7 |
3 | 1814.16 | 25 | 12.16 | 2593 | 7 | 7 |
4 | 1380.40 | 25 | 12.56 | 2126 | 7 | 7 |
5 | 713.24 | 25 | 13.18 | 1347 | 7 | 8 |
6 | 145.12 | 25 | 13.91 | 634 | 7 | 8 |
7 | 85.68 | 25 | 14.09 | 541 | 7 | 8 |
8 | 0.08 | 25 | 14.30 | 420 | 8 | 8 |
9 | 0.04 | 200 | 14.08 | 394 | 9 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.00 | 39 | 14.23 | 500 | 7 | 17 |
2 | 2003.64 | 70 | 10.36 | 2843 | 17 | 7 |
3 | 1824.56 | 25 | 12.12 | 2622 | 7 | 7 |
4 | 1348.72 | 25 | 12.60 | 2074 | 7 | 7 |
5 | 907.32 | 25 | 13.01 | 1562 | 7 | 8 |
6 | 206.64 | 25 | 13.78 | 718 | 7 | 8 |
7 | 106.56 | 25 | 14.00 | 580 | 7 | 8 |
8 | 1.64 | 25 | 14.27 | 424 | 7 | 8 |
9 | 0.08 | 201 | 14.04 | 393 | 7 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.72 | 39 | 14.17 | 519 | 7 | 14 |
2 | 2003.64 | 70 | 10.47 | 2790 | 14 | 7 |
3 | 1816.96 | 25 | 12.12 | 2628 | 7 | 6 |
4 | 1357.92 | 25 | 12.53 | 2124 | 7 | 7 |
5 | 705.56 | 25 | 13.17 | 1355 | 7 | 8 |
6 | 159.76 | 25 | 13.92 | 651 | 7 | 8 |
7 | 89.56 | 25 | 14.13 | 541 | 7 | 7 |
8 | 0.08 | 25 | 14.32 | 414 | 7 | 7 |
9 | 0.08 | 200 | 14.11 | 386 | 7 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.80 | 39 | 14.17 | 538 | 7 | 22 |
2 | 2010.60 | 70 | 10.54 | 2772 | 22 | 7 |
3 | 1818.08 | 25 | 12.16 | 2574 | 7 | 6 |
4 | 1382.96 | 25 | 12.55 | 2143 | 7 | 7 |
5 | 895.48 | 25 | 13.01 | 1563 | 7 | 8 |
6 | 194.68 | 25 | 13.79 | 699 | 7 | 9 |
7 | 104.32 | 25 | 14.03 | 568 | 7 | 8 |
8 | 0.08 | 201 | 14.07 | 397 | 7 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.16 | 39 | 14.17 | 519 | 7 | 16 |
2 | 2009.08 | 70 | 10.54 | 2739 | 16 | 7 |
3 | 1816.68 | 25 | 12.19 | 2576 | 7 | 7 |
4 | 1363.08 | 25 | 12.56 | 2114 | 7 | 7 |
5 | 894.04 | 25 | 12.99 | 1574 | 7 | 8 |
6 | 179.00 | 25 | 13.84 | 693 | 7 | 8 |
7 | 95.44 | 25 | 14.02 | 568 | 7 | 8 |
8 | 0.16 | 25 | 14.29 | 420 | 7 | 7 |
9 | 0.08 | 200 | 14.03 | 396 | 7 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.40 | 39 | 14.17 | 500 | 7 | 13 |
2 | 2006.64 | 70 | 10.51 | 2757 | 13 | 7 |
3 | 1804.96 | 25 | 12.15 | 2653 | 7 | 7 |
4 | 1358.44 | 25 | 12.59 | 2112 | 7 | 7 |
5 | 887.56 | 25 | 13.05 | 1547 | 7 | 8 |
6 | 167.56 | 25 | 13.84 | 668 | 7 | 9 |
7 | 88.84 | 25 | 14.03 | 560 | 7 | 8 |
8 | 0.12 | 201 | 14.05 | 400 | 7 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.20 | 39 | 14.10 | 519 | 8 | 15 |
2 | 2002.60 | 70 | 10.55 | 2779 | 15 | 6 |
3 | 1816.64 | 25 | 12.14 | 2647 | 7 | 6 |
4 | 1373.88 | 25 | 12.58 | 2136 | 7 | 7 |
5 | 700.44 | 25 | 13.20 | 1334 | 7 | 8 |
6 | 138.80 | 25 | 13.92 | 630 | 7 | 8 |
7 | 79.80 | 25 | 14.10 | 539 | 7 | 8 |
8 | -0.00 | 25 | 14.30 | 422 | 7 | 7 |
9 | -0.00 | 200 | 14.04 | 391 | 7 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.88 | 39 | 14.17 | 519 | 7 | 16 |
2 | 2007.96 | 70 | 10.42 | 2813 | 16 | 7 |
3 | 1815.32 | 25 | 12.15 | 2645 | 7 | 7 |
4 | 1600.20 | 25 | 12.39 | 2387 | 7 | 7 |
5 | 691.00 | 25 | 13.21 | 1328 | 7 | 8 |
6 | 236.60 | 25 | 13.76 | 765 | 7 | 8 |
7 | 108.44 | 25 | 13.98 | 595 | 7 | 9 |
8 | 1.48 | 200 | 14.03 | 400 | 8 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.12 | 39 | 14.17 | 538 | 8 | 22 |
2 | 2001.68 | 70 | 10.29 | 2872 | 22 | 7 |
3 | 1808.76 | 25 | 12.23 | 2620 | 7 | 7 |
4 | 1353.72 | 25 | 12.59 | 2122 | 7 | 7 |
5 | 694.44 | 25 | 13.20 | 1345 | 7 | 8 |
6 | 229.92 | 25 | 13.76 | 765 | 7 | 9 |
7 | 104.16 | 25 | 14.02 | 593 | 7 | 8 |
8 | 0.04 | 201 | 14.04 | 400 | 7 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 39 | 14.10 | 519 | 7 | 16 |
2 | 2001.04 | 70 | 10.49 | 2742 | 16 | 6 |
3 | 1811.48 | 25 | 12.28 | 2511 | 6 | 6 |
4 | 1359.36 | 25 | 12.64 | 2099 | 7 | 7 |
5 | 677.60 | 25 | 13.25 | 1297 | 7 | 8 |
6 | 209.60 | 25 | 13.77 | 743 | 7 | 9 |
7 | 99.44 | 25 | 14.02 | 585 | 7 | 8 |
8 | 0.08 | 25 | 14.28 | 436 | 7 | 7 |
9 | 0.04 | 200 | 13.96 | 401 | 8 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.80 | 39 | 14.17 | 519 | 7 | 14 |
2 | 2011.76 | 70 | 10.20 | 2855 | 14 | 7 |
3 | 1817.64 | 25 | 12.20 | 2626 | 7 | 7 |
4 | 1378.20 | 25 | 12.60 | 2137 | 7 | 7 |
5 | 704.68 | 25 | 13.20 | 1355 | 7 | 8 |
6 | 144.00 | 25 | 13.94 | 639 | 7 | 8 |
7 | 84.12 | 25 | 14.10 | 551 | 7 | 7 |
8 | 0.12 | 25 | 14.33 | 424 | 7 | 7 |
9 | -0.00 | 200 | 14.04 | 396 | 7 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 38 | 14.17 | 519 | 7 | 16 |
2 | 2002.20 | 70 | 10.19 | 2842 | 16 | 7 |
3 | 1790.48 | 25 | 12.22 | 2586 | 7 | 7 |
4 | 1363.72 | 25 | 12.58 | 2132 | 7 | 7 |
5 | 896.36 | 25 | 13.03 | 1566 | 7 | 8 |
6 | 199.60 | 25 | 13.82 | 707 | 7 | 9 |
7 | 99.04 | 25 | 14.02 | 576 | 7 | 8 |
8 | 0.08 | 201 | 14.03 | 400 | 7 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.56 | 38 | 14.17 | 519 | 10 | 22 |
2 | 1904.12 | 70 | 10.16 | 2756 | 22 | 6 |
3 | 1712.68 | 25 | 12.33 | 2482 | 6 | 7 |
4 | 1275.68 | 25 | 12.73 | 2003 | 6 | 7 |
5 | 826.44 | 25 | 13.14 | 1468 | 7 | 8 |
6 | 161.60 | 25 | 13.88 | 662 | 7 | 9 |
7 | 92.76 | 25 | 14.10 | 551 | 7 | 8 |
8 | 0.08 | 25 | 14.33 | 422 | 7 | 7 |
9 | -0.00 | 200 | 14.01 | 391 | 7 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.24 | 38 | 14.23 | 519 | 9 | 19 |
2 | 1885.80 | 70 | 10.14 | 2726 | 19 | 7 |
3 | 1695.36 | 25 | 12.35 | 2459 | 7 | 7 |
4 | 1251.00 | 25 | 12.73 | 1984 | 7 | 7 |
5 | 807.00 | 25 | 13.15 | 1455 | 7 | 8 |
6 | 173.32 | 25 | 13.91 | 672 | 7 | 8 |
7 | 85.20 | 25 | 14.12 | 541 | 7 | 8 |
8 | 0.16 | 25 | 14.31 | 416 | 9 | 8 |
9 | 0.08 | 200 | 14.03 | 387 | 10 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.08 | 38 | 14.23 | 500 | 7 | 22 |
2 | 2003.20 | 70 | 10.06 | 2846 | 22 | 7 |
3 | 1821.72 | 25 | 12.25 | 2620 | 7 | 7 |
4 | 1383.76 | 25 | 12.66 | 2122 | 7 | 7 |
5 | 713.76 | 25 | 13.27 | 1355 | 7 | 8 |
6 | 261.76 | 25 | 13.76 | 797 | 7 | 9 |
7 | 60.04 | 25 | 14.14 | 522 | 7 | 7 |
8 | 0.08 | 25 | 14.34 | 422 | 8 | 9 |
9 | 0.12 | 200 | 14.02 | 394 | 9 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.76 | 38 | 14.17 | 519 | 7 | 15 |
2 | 2001.72 | 70 | 9.93 | 2825 | 15 | 6 |
3 | 1834.44 | 25 | 12.18 | 2676 | 7 | 7 |
4 | 1404.16 | 25 | 12.68 | 2145 | 7 | 7 |
5 | 732.28 | 25 | 13.27 | 1366 | 7 | 8 |
6 | 277.12 | 25 | 13.73 | 816 | 7 | 9 |
7 | 79.36 | 25 | 14.14 | 532 | 7 | 7 |
8 | 0.12 | 25 | 14.37 | 416 | 7 | 7 |
9 | 0.08 | 200 | 14.06 | 386 | 7 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.92 | 38 | 14.23 | 500 | 8 | 18 |
2 | 2009.44 | 70 | 10.21 | 2753 | 18 | 6 |
3 | 1861.72 | 25 | 12.29 | 2641 | 6 | 6 |
4 | 1419.48 | 25 | 12.65 | 2182 | 7 | 7 |
5 | 946.80 | 25 | 13.06 | 1634 | 7 | 8 |
6 | 211.96 | 25 | 13.84 | 726 | 7 | 9 |
7 | 108.16 | 25 | 14.08 | 576 | 7 | 8 |
8 | 0.04 | 201 | 14.07 | 390 | 7 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.24 | 38 | 14.23 | 519 | 7 | 23 |
2 | 2006.64 | 70 | 10.18 | 2803 | 23 | 6 |
3 | 1803.12 | 25 | 12.34 | 2605 | 6 | 6 |
4 | 1384.24 | 25 | 12.73 | 2124 | 6 | 7 |
5 | 909.92 | 25 | 13.11 | 1576 | 7 | 8 |
6 | 217.44 | 25 | 13.85 | 738 | 7 | 8 |
7 | 56.64 | 25 | 14.20 | 499 | 7 | 7 |
8 | 0.12 | 25 | 14.34 | 420 | 7 | 7 |
9 | 0.12 | 200 | 14.04 | 392 | 8 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.08 | 38 | 14.23 | 519 | 7 | 20 |
2 | 2003.08 | 70 | 10.24 | 2772 | 20 | 7 |
3 | 1823.00 | 25 | 12.30 | 2628 | 7 | 7 |
4 | 1611.60 | 25 | 12.54 | 2372 | 7 | 7 |
5 | 681.36 | 25 | 13.34 | 1299 | 7 | 8 |
6 | 221.16 | 25 | 13.88 | 728 | 7 | 8 |
7 | 112.48 | 25 | 14.11 | 576 | 7 | 8 |
8 | 0.16 | 200 | 14.09 | 388 | 7 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.52 | 38 | 14.29 | 500 | 7 | 21 |
2 | 2011.16 | 70 | 10.36 | 2794 | 21 | 7 |
3 | 1805.52 | 25 | 12.37 | 2584 | 7 | 6 |
4 | 1354.92 | 25 | 12.74 | 2095 | 7 | 7 |
5 | 898.48 | 25 | 13.13 | 1576 | 7 | 8 |
6 | 194.80 | 25 | 13.88 | 712 | 7 | 8 |
7 | 99.20 | 25 | 14.13 | 564 | 7 | 8 |
8 | 0.16 | 201 | 14.08 | 393 | 7 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.04 | 38 | 14.29 | 480 | 7 | 15 |
2 | 2002.92 | 70 | 10.45 | 2791 | 15 | 7 |
3 | 1805.20 | 25 | 12.34 | 2624 | 7 | 6 |
4 | 1154.64 | 25 | 12.92 | 1878 | 6 | 7 |
5 | 702.00 | 25 | 13.34 | 1330 | 7 | 8 |
6 | 153.76 | 25 | 14.03 | 645 | 7 | 7 |
7 | 72.84 | 25 | 14.22 | 526 | 7 | 7 |
8 | 0.20 | 25 | 14.40 | 420 | 7 | 10 |
9 | -0.00 | 200 | 14.10 | 388 | 7 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.00 | 38 | 14.29 | 500 | 8 | 13 |
2 | 2010.24 | 70 | 10.54 | 2742 | 13 | 6 |
3 | 1842.96 | 25 | 12.37 | 2632 | 6 | 6 |
4 | 1393.16 | 25 | 12.75 | 2139 | 7 | 7 |
5 | 720.24 | 25 | 13.33 | 1349 | 7 | 8 |
6 | 156.68 | 25 | 14.03 | 636 | 7 | 7 |
7 | 80.24 | 25 | 14.23 | 528 | 7 | 7 |
8 | 0.12 | 25 | 14.42 | 409 | 7 | 7 |
9 | 0.04 | 200 | 14.10 | 382 | 7 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.96 | 38 | 14.29 | 519 | 7 | 17 |
2 | 2007.88 | 70 | 10.59 | 2795 | 17 | 7 |
3 | 1798.84 | 25 | 12.40 | 2612 | 7 | 7 |
4 | 1141.68 | 25 | 12.97 | 1864 | 7 | 7 |
5 | 696.56 | 25 | 13.38 | 1328 | 7 | 8 |
6 | 141.44 | 25 | 14.06 | 618 | 7 | 7 |
7 | 71.80 | 25 | 14.25 | 519 | 7 | 7 |
8 | 0.12 | 25 | 14.43 | 411 | 7 | 7 |
9 | 0.04 | 200 | 14.10 | 385 | 8 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.84 | 37 | 14.29 | 500 | 7 | 16 |
2 | 2011.60 | 70 | 10.72 | 2826 | 16 | 6 |
3 | 1817.16 | 25 | 12.41 | 2641 | 6 | 7 |
4 | 1356.64 | 25 | 12.81 | 2111 | 7 | 7 |
5 | 663.68 | 25 | 13.44 | 1276 | 7 | 8 |
6 | 134.44 | 25 | 14.10 | 611 | 7 | 7 |
7 | 67.32 | 25 | 14.24 | 517 | 7 | 7 |
8 | 0.12 | 25 | 14.42 | 414 | 7 | 7 |
9 | 0.08 | 200 | 14.11 | 384 | 7 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.72 | 37 | 14.23 | 519 | 7 | 16 |
2 | 2012.08 | 70 | 10.80 | 2809 | 16 | 6 |
3 | 1824.80 | 25 | 12.45 | 2628 | 6 | 6 |
4 | 1146.04 | 25 | 13.02 | 1859 | 6 | 7 |
5 | 697.16 | 25 | 13.41 | 1318 | 7 | 8 |
6 | 145.28 | 25 | 14.10 | 611 | 7 | 7 |
7 | 78.84 | 25 | 14.26 | 522 | 7 | 7 |
8 | 0.08 | 25 | 14.45 | 405 | 7 | 9 |
9 | 0.04 | 200 | 14.12 | 385 | 7 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.28 | 37 | 14.29 | 519 | 7 | 14 |
2 | 2009.28 | 70 | 11.11 | 2779 | 14 | 7 |
3 | 1801.64 | 25 | 12.51 | 2588 | 6 | 6 |
4 | 1135.40 | 25 | 13.05 | 1838 | 7 | 7 |
5 | 683.76 | 25 | 13.44 | 1303 | 7 | 8 |
6 | 140.16 | 25 | 14.12 | 611 | 7 | 7 |
7 | 65.16 | 25 | 14.31 | 497 | 7 | 7 |
8 | 0.08 | 25 | 14.47 | 412 | 7 | 7 |
9 | 0.12 | 200 | 14.13 | 383 | 7 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.00 | 38 | 14.29 | 500 | 10 | 16 |
2 | 972.40 | -1 | 14.29 | 500 | 10 | 16 |
3 | 2002.12 | 70 | 11.27 | 2804 | 16 | 7 |
4 | 1796.28 | 25 | 12.53 | 2589 | 7 | 7 |
5 | 1133.60 | 25 | 13.07 | 1836 | 7 | 7 |
6 | 471.44 | 25 | 13.66 | 1055 | 7 | 8 |
7 | 135.40 | 25 | 14.11 | 616 | 7 | 7 |
8 | 62.60 | 25 | 14.29 | 507 | 7 | 7 |
9 | 0.12 | 201 | 14.13 | 395 | 7 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.84 | 38 | 14.23 | 538 | 8 | 14 |
2 | 2001.88 | 70 | 11.42 | 2788 | 14 | 6 |
3 | 1782.08 | 25 | 12.58 | 2564 | 7 | 6 |
4 | 1120.04 | 25 | 13.10 | 1828 | 7 | 7 |
5 | 654.44 | 25 | 13.50 | 1270 | 7 | 8 |
6 | 171.56 | 25 | 14.01 | 686 | 7 | 8 |
7 | 79.68 | 25 | 14.25 | 541 | 7 | 8 |
8 | 0.08 | 25 | 14.43 | 426 | 7 | 7 |
9 | -0.00 | 200 | 14.07 | 401 | 10 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 37 | 14.29 | 519 | 7 | 15 |
2 | 2008.32 | 70 | 11.59 | 2758 | 15 | 7 |
3 | 1796.40 | 25 | 12.62 | 2587 | 7 | 7 |
4 | 1101.08 | 25 | 13.14 | 1793 | 7 | 7 |
5 | 647.24 | 25 | 13.52 | 1261 | 7 | 8 |
6 | 102.92 | 25 | 14.21 | 572 | 7 | 7 |
7 | 21.00 | 25 | 14.37 | 451 | 7 | 7 |
8 | 0.08 | 25 | 14.40 | 416 | 7 | 7 |
9 | 0.12 | 200 | 14.10 | 394 | 8 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 37 | 14.29 | 538 | 7 | 15 |
2 | 2008.60 | 70 | 11.70 | 2816 | 15 | 7 |
3 | 1789.56 | 25 | 12.63 | 2599 | 6 | 7 |
4 | 1136.56 | 25 | 13.13 | 1835 | 7 | 7 |
5 | 439.64 | 25 | 13.71 | 1013 | 7 | 8 |
6 | 123.24 | 25 | 14.18 | 601 | 7 | 7 |
7 | 0.12 | 25 | 14.47 | 414 | 7 | 7 |
8 | 0.08 | 200 | 14.13 | 388 | 7 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.04 | 37 | 14.36 | 519 | 8 | 12 |
2 | 2010.88 | 70 | 11.82 | 2846 | 12 | 7 |
3 | 1613.96 | 25 | 12.79 | 2399 | 6 | 7 |
4 | 975.00 | 25 | 13.23 | 1680 | 7 | 7 |
5 | 320.48 | 25 | 13.85 | 882 | 7 | 8 |
6 | 147.64 | 25 | 14.12 | 655 | 7 | 8 |
7 | 0.08 | 25 | 14.45 | 432 | 7 | 7 |
8 | 0.08 | 200 | 14.10 | 398 | 7 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 37 | 14.36 | 519 | 7 | 14 |
2 | 2000.88 | 70 | 12.03 | 2748 | 14 | 7 |
3 | 1792.28 | 25 | 12.71 | 2609 | 7 | 7 |
4 | 875.96 | 25 | 13.38 | 1532 | 7 | 7 |
5 | 426.96 | 25 | 13.76 | 1017 | 7 | 9 |
6 | 117.24 | 25 | 14.23 | 589 | 7 | 7 |
7 | 0.12 | 25 | 14.49 | 420 | 7 | 13 |
8 | 0.12 | 200 | 14.14 | 392 | 8 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.00 | 37 | 14.36 | 519 | 8 | 11 |
2 | 2007.44 | 70 | 12.04 | 2818 | 11 | 7 |
3 | 1557.68 | 25 | 12.90 | 2336 | 7 | 7 |
4 | 910.92 | 25 | 13.35 | 1576 | 7 | 7 |
5 | 457.80 | 25 | 13.75 | 1041 | 7 | 8 |
6 | 119.76 | 25 | 14.21 | 607 | 7 | 7 |
7 | 24.20 | 25 | 14.41 | 453 | 7 | 7 |
8 | 0.04 | 25 | 14.41 | 420 | 7 | 7 |
9 | -0.00 | 200 | 14.10 | 392 | 7 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.36 | 37 | 14.36 | 519 | 7 | 25 |
2 | 2005.64 | 70 | 12.10 | 2813 | 25 | 6 |
3 | 1559.28 | 25 | 12.90 | 2349 | 6 | 7 |
4 | 1089.92 | 25 | 13.23 | 1803 | 7 | 7 |
5 | 377.88 | 25 | 13.83 | 947 | 7 | 8 |
6 | 100.44 | 25 | 14.28 | 566 | 7 | 7 |
7 | 5.04 | 25 | 14.47 | 426 | 7 | 7 |
8 | 0.12 | 25 | 14.40 | 416 | 7 | 7 |
9 | -0.00 | 200 | 14.12 | 388 | 8 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 37 | 14.36 | 519 | 7 | 11 |
2 | 2006.00 | 70 | 12.17 | 2823 | 11 | 7 |
3 | 1785.60 | 25 | 12.81 | 2601 | 7 | 7 |
4 | 882.52 | 25 | 13.42 | 1555 | 7 | 7 |
5 | 227.28 | 25 | 14.03 | 765 | 7 | 8 |
6 | 132.92 | 25 | 14.23 | 624 | 7 | 8 |
7 | 0.16 | 25 | 14.52 | 414 | 7 | 7 |
8 | -0.00 | 200 | 14.16 | 390 | 7 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.28 | 37 | 14.36 | 519 | 7 | |
2 | 2008.00 | 70 | 12.18 | 2828 | 6 | |
3 | 1583.12 | 25 | 12.94 | 2391 | 6 | 7 |
4 | 1132.68 | 25 | 13.25 | 1843 | 7 | 7 |
5 | 399.60 | 25 | 13.87 | 951 | 7 | 8 |
6 | 103.80 | 25 | 14.28 | 568 | 7 | 7 |
7 | 0.16 | 25 | 14.54 | 420 | 7 | 7 |
8 | 0.04 | 200 | 14.17 | 389 | 7 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.56 | 37 | 14.42 | 480 | 7 | 186 |
2 | 2010.04 | 80 | 12.12 | 2864 | 186 | 7 |
3 | 1343.52 | 25 | 13.13 | 2070 | 7 | 7 |
4 | 658.48 | 25 | 13.63 | 1276 | 7 | 8 |
5 | 193.68 | 25 | 14.10 | 707 | 7 | 8 |
6 | 92.08 | 25 | 14.26 | 564 | 7 | 8 |
7 | 0.12 | 25 | 14.47 | 428 | 7 | 7 |
8 | 0.08 | 272 | 14.07 | 396 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.92 | 37 | 14.36 | 557 | 7 | |
2 | 2011.04 | 80 | 12.19 | 2821 | 7 | |
3 | 1319.88 | 25 | 13.14 | 2062 | 7 | 7 |
4 | 867.44 | 25 | 13.49 | 1524 | 7 | 8 |
5 | 175.36 | 25 | 14.15 | 676 | 7 | 8 |
6 | 96.72 | 25 | 14.32 | 562 | 7 | 7 |
7 | 0.12 | 25 | 14.50 | 426 | 7 | 7 |
8 | 0.08 | 272 | 14.11 | 391 | 7 | 186 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 37 | 14.42 | 500 | 7 | |
2 | 2009.20 | 80 | 12.26 | 2766 | 7 | |
3 | 1340.72 | 25 | 13.19 | 2076 | 7 | 7 |
4 | 669.12 | 25 | 13.64 | 1295 | 7 | 8 |
5 | 145.96 | 25 | 14.26 | 641 | 7 | 7 |
6 | 87.52 | 25 | 14.38 | 539 | 7 | 7 |
7 | 0.12 | 25 | 14.55 | 414 | 7 | 7 |
8 | 0.08 | 269 | 14.17 | 383 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.44 | 36 | 14.42 | 480 | 7 | 177 |
2 | 2004.72 | 80 | 12.27 | 2763 | 177 | 6 |
3 | 1332.60 | 25 | 13.20 | 2060 | 7 | 7 |
4 | 674.64 | 25 | 13.68 | 1274 | 7 | 8 |
5 | 216.92 | 25 | 14.13 | 730 | 7 | 8 |
6 | 104.72 | 25 | 14.30 | 570 | 7 | 7 |
7 | 0.12 | 25 | 14.53 | 418 | 7 | 7 |
8 | 0.08 | 269 | 14.11 | 390 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.28 | 36 | 14.36 | 519 | 8 | |
2 | 2001.72 | 80 | 12.26 | 2811 | 7 | |
3 | 1297.04 | 25 | 13.25 | 2045 | 7 | 7 |
4 | 823.32 | 25 | 13.57 | 1486 | 7 | 8 |
5 | 156.84 | 25 | 14.23 | 655 | 7 | 8 |
6 | 80.04 | 25 | 14.34 | 545 | 7 | 7 |
7 | 0.04 | 25 | 14.50 | 426 | 7 | 7 |
8 | 0.08 | 266 | 14.12 | 389 | 7 | 177 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.16 | 36 | 14.42 | 500 | 7 | |
2 | 2006.76 | 80 | 12.28 | 2814 | 7 | |
3 | 1314.04 | 25 | 13.26 | 2061 | 7 | 7 |
4 | 655.12 | 25 | 13.71 | 1274 | 7 | 8 |
5 | 191.44 | 25 | 14.15 | 718 | 7 | 8 |
6 | 86.48 | 25 | 14.31 | 559 | 7 | 8 |
7 | 0.04 | 25 | 14.49 | 424 | 7 | 7 |
8 | 0.04 | 261 | 14.09 | 395 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.72 | 37 | 14.36 | 519 | 8 | 181 |
2 | 971.68 | -1 | 14.36 | 519 | 8 | 181 |
3 | 2004.68 | 80 | 12.29 | 2828 | 181 | 7 |
4 | 1303.28 | 25 | 13.29 | 2049 | 7 | 7 |
5 | 623.36 | 25 | 13.72 | 1259 | 7 | 8 |
6 | 170.16 | 25 | 14.20 | 690 | 7 | 8 |
7 | 87.12 | 25 | 14.33 | 557 | 7 | 7 |
8 | 0.12 | 25 | 14.51 | 434 | 7 | 8 |
9 | 0.04 | 266 | 14.11 | 393 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.08 | 37 | 14.42 | 480 | 7 | |
2 | 2006.68 | 80 | 12.29 | 2838 | 7 | |
3 | 1517.12 | 25 | 13.16 | 2303 | 7 | 7 |
4 | 811.96 | 25 | 13.60 | 1462 | 7 | 8 |
5 | 160.80 | 25 | 14.21 | 666 | 7 | 8 |
6 | 90.56 | 25 | 14.33 | 553 | 7 | 7 |
7 | 0.12 | 25 | 14.52 | 416 | 7 | 7 |
8 | 0.04 | 264 | 14.13 | 385 | 8 | 181 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.80 | 37 | 14.36 | 519 | 8 | 185 |
2 | 2012.60 | 80 | 12.31 | 2809 | 185 | 7 |
3 | 1335.52 | 25 | 13.25 | 2093 | 6 | 7 |
4 | 670.00 | 25 | 13.71 | 1299 | 7 | 8 |
5 | 135.72 | 25 | 14.29 | 620 | 7 | 7 |
6 | 78.24 | 25 | 14.39 | 530 | 7 | 7 |
7 | 0.08 | 25 | 14.56 | 416 | 7 | 7 |
8 | -0.00 | 264 | 14.15 | 388 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.20 | 37 | 14.42 | 500 | 7 | |
2 | 2005.96 | 81 | 12.34 | 2806 | 7 | |
3 | 1331.12 | 25 | 13.24 | 2113 | 7 | 7 |
4 | 654.44 | 25 | 13.73 | 1284 | 7 | 8 |
5 | 187.28 | 25 | 14.18 | 713 | 7 | 8 |
6 | 95.16 | 25 | 14.34 | 568 | 7 | 7 |
7 | 0.04 | 25 | 14.53 | 432 | 7 | 8 |
8 | 0.12 | 266 | 14.13 | 391 | 8 | 185 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.20 | 37 | 14.42 | 500 | 8 | |
2 | 2009.60 | 80 | 12.35 | 2797 | 6 | |
3 | 1527.20 | 25 | 13.17 | 2314 | 6 | 7 |
4 | 605.44 | 25 | 13.79 | 1218 | 7 | 8 |
5 | 154.24 | 25 | 14.24 | 668 | 7 | 8 |
6 | 82.48 | 25 | 14.33 | 555 | 7 | 7 |
7 | 0.20 | 25 | 14.51 | 430 | 7 | 9 |
8 | -0.00 | 264 | 14.11 | 390 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.72 | 37 | 14.42 | 500 | 7 | |
2 | 2007.24 | 80 | 12.34 | 2817 | 6 | |
3 | 1288.88 | 25 | 13.29 | 2030 | 6 | 7 |
4 | 831.20 | 25 | 13.60 | 1489 | 7 | 8 |
5 | 161.00 | 25 | 14.22 | 672 | 7 | 8 |
6 | 83.00 | 25 | 14.35 | 555 | 7 | 8 |
7 | -0.00 | 25 | 14.53 | 426 | 7 | 8 |
8 | -0.04 | 253 | 14.11 | 390 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.80 | 37 | 14.36 | 500 | 7 | 168 |
2 | 2003.76 | 80 | 12.37 | 2787 | 168 | 7 |
3 | 1306.24 | 25 | 13.29 | 2055 | 7 | 7 |
4 | 845.76 | 25 | 13.59 | 1511 | 7 | 8 |
5 | 172.52 | 25 | 14.22 | 686 | 7 | 8 |
6 | 89.72 | 25 | 14.33 | 562 | 7 | 7 |
7 | 0.12 | 25 | 14.55 | 432 | 7 | 8 |
8 | 0.08 | 264 | 14.11 | 395 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.04 | 37 | 14.36 | 519 | 8 | 176 |
2 | 2009.84 | 80 | 12.33 | 2835 | 176 | 6 |
3 | 1320.80 | 25 | 13.28 | 2064 | 7 | 7 |
4 | 643.64 | 25 | 13.73 | 1280 | 7 | 8 |
5 | 175.48 | 25 | 14.19 | 701 | 7 | 8 |
6 | 87.92 | 25 | 14.33 | 568 | 7 | 7 |
7 | 0.08 | 25 | 14.53 | 438 | 7 | 7 |
8 | 0.08 | 261 | 14.11 | 392 | 7 | 168 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.68 | 36 | 14.42 | 519 | 7 | 155 |
2 | 2007.72 | 80 | 12.35 | 2825 | 155 | 7 |
3 | 1515.52 | 25 | 13.19 | 2282 | 7 | 7 |
4 | 792.36 | 25 | 13.63 | 1428 | 7 | 8 |
5 | 150.00 | 25 | 14.26 | 643 | 7 | 8 |
6 | 81.52 | 25 | 14.36 | 543 | 7 | 7 |
7 | 0.20 | 25 | 14.57 | 416 | 8 | 7 |
8 | 0.12 | 264 | 14.12 | 390 | 8 | 176 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.24 | 36 | 14.42 | 500 | 7 | 218 |
2 | 2007.96 | 80 | 12.37 | 2831 | 218 | 6 |
3 | 1330.80 | 25 | 13.27 | 2091 | 6 | 7 |
4 | 644.48 | 25 | 13.74 | 1272 | 7 | 8 |
5 | 174.04 | 25 | 14.21 | 688 | 7 | 8 |
6 | 84.16 | 25 | 14.36 | 553 | 7 | 7 |
7 | 0.08 | 25 | 14.56 | 426 | 7 | 10 |
8 | -0.00 | 261 | 14.12 | 388 | 7 | 155 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.68 | 36 | 14.42 | 500 | 7 | |
2 | 2009.68 | 80 | 12.42 | 2779 | 7 | |
3 | 1311.24 | 25 | 13.30 | 2024 | 7 | 7 |
4 | 839.08 | 25 | 13.61 | 1461 | 7 | 7 |
5 | 160.28 | 25 | 14.24 | 653 | 7 | 8 |
6 | 80.36 | 25 | 14.38 | 538 | 7 | 7 |
7 | 0.08 | 25 | 14.57 | 416 | 7 | 8 |
8 | -0.00 | 261 | 14.13 | 386 | 7 | 218 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 36 | 14.42 | 500 | 7 | |
2 | 2005.16 | 80 | 12.42 | 2831 | 6 | |
3 | 1101.32 | 25 | 13.44 | 1768 | 6 | 7 |
4 | 676.24 | 25 | 13.73 | 1288 | 7 | 8 |
5 | 126.68 | 25 | 14.32 | 607 | 7 | 7 |
6 | 65.92 | 25 | 14.41 | 511 | 7 | 7 |
7 | 0.16 | 25 | 14.57 | 426 | 7 | 8 |
8 | -0.00 | 261 | 14.14 | 382 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.84 | 35 | 14.42 | 500 | 9 | |
2 | 2004.20 | 80 | 12.51 | 2761 | 6 | |
3 | 1288.68 | 25 | 13.31 | 1995 | 6 | 7 |
4 | 615.68 | 25 | 13.77 | 1213 | 7 | 8 |
5 | 151.08 | 25 | 14.24 | 651 | 7 | 8 |
6 | 74.32 | 25 | 14.39 | 528 | 7 | 8 |
7 | 0.08 | 25 | 14.58 | 416 | 7 | 10 |
8 | 0.08 | 258 | 14.12 | 386 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.92 | 36 | 14.42 | 500 | 7 | |
2 | 2008.60 | 80 | 12.50 | 2798 | 6 | |
3 | 1294.80 | 25 | 13.29 | 2020 | 6 | 7 |
4 | 612.08 | 25 | 13.77 | 1209 | 7 | 8 |
5 | 148.88 | 25 | 14.25 | 651 | 7 | 8 |
6 | 72.76 | 25 | 14.39 | 526 | 7 | 7 |
7 | 0.08 | 25 | 14.59 | 414 | 7 | 7 |
8 | -0.04 | 258 | 14.12 | 382 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.08 | 35 | 14.42 | 500 | 7 | 230 |
2 | 2001.56 | 80 | 12.52 | 2824 | 230 | 7 |
3 | 1307.48 | 25 | 13.29 | 2017 | 6 | 7 |
4 | 605.16 | 25 | 13.77 | 1207 | 7 | 7 |
5 | 109.56 | 25 | 14.40 | 580 | 7 | 7 |
6 | 54.84 | 25 | 14.45 | 493 | 7 | 7 |
7 | -0.00 | 285 | 14.17 | 382 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.60 | 35 | 14.42 | 519 | 7 | |
2 | 1961.08 | 80 | 12.68 | 2709 | 6 | |
3 | 1248.60 | 25 | 13.32 | 1945 | 7 | 7 |
4 | 548.48 | 25 | 13.84 | 1143 | 7 | 7 |
5 | 141.28 | 25 | 14.33 | 643 | 7 | 7 |
6 | 69.88 | 25 | 14.42 | 536 | 7 | 7 |
7 | 0.08 | 25 | 14.62 | 422 | 7 | 7 |
8 | -0.00 | 264 | 14.11 | 384 | 7 | 230 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.48 | 33 | 14.48 | 500 | 7 | |
2 | 1054.28 | 1 | 14.55 | 1750 | 7 | |
3 | 1950.64 | 80 | 12.66 | 2723 | 6 | |
4 | 1219.68 | 25 | 13.31 | 1920 | 6 | 7 |
5 | 514.36 | 25 | 13.87 | 1089 | 7 | 7 |
6 | 129.32 | 25 | 14.34 | 622 | 7 | 7 |
7 | 58.56 | 25 | 14.43 | 509 | 7 | 7 |
8 | -0.08 | 284 | 14.10 | 391 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.52 | 34 | 14.42 | 500 | 7 | |
2 | 1764.48 | 80 | 12.79 | 2517 | 7 | |
3 | 1078.28 | 25 | 13.38 | 1772 | 7 | 7 |
4 | 417.56 | 25 | 13.96 | 968 | 7 | 7 |
5 | 97.08 | 25 | 14.41 | 557 | 7 | 7 |
6 | 6.44 | 25 | 14.57 | 411 | 7 | 7 |
7 | 0.12 | 25 | 14.48 | 391 | 7 | 7 |
8 | 0.04 | 256 | 14.09 | 367 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.80 | 34 | 14.42 | 519 | 7 | |
2 | 1758.28 | 80 | 12.78 | 2509 | 7 | |
3 | 1290.96 | 25 | 13.27 | 2011 | 6 | 7 |
4 | 362.48 | 25 | 13.98 | 905 | 7 | 7 |
5 | 87.56 | 25 | 14.42 | 541 | 7 | 7 |
6 | 39.76 | 25 | 14.44 | 472 | 7 | 7 |
7 | 0.12 | 25 | 14.52 | 405 | 7 | 7 |
8 | 0.12 | 258 | 14.07 | 376 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.20 | 34 | 14.42 | 500 | 8 | |
2 | 1504.16 | 80 | 12.90 | 2227 | 7 | |
3 | 840.88 | 25 | 13.50 | 1488 | 7 | 7 |
4 | 198.56 | 25 | 14.18 | 709 | 7 | 7 |
5 | 102.56 | 25 | 14.33 | 570 | 7 | 7 |
6 | 1.16 | 295 | 14.09 | 383 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.60 | 34 | 14.29 | 519 | 9 | 172 |
2 | 1510.84 | 80 | 12.84 | 2244 | 172 | 7 |
3 | 1050.44 | 25 | 13.32 | 1728 | 7 | 7 |
4 | 357.52 | 25 | 13.89 | 911 | 7 | 9 |
5 | 82.84 | 25 | 14.33 | 541 | 7 | 8 |
6 | -0.00 | 300 | 14.05 | 377 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.88 | 25 | 14.55 | 461 | 8 | |
2 | 1128.52 | 3 | 14.04 | 1826 | 8 | |
3 | 1202.72 | 80 | 12.87 | 1884 | 7 | |
4 | 162.00 | 25 | 14.10 | 663 | 7 | 8 |
5 | 76.52 | 25 | 14.28 | 534 | 7 | 8 |
6 | 0.08 | 25 | 14.49 | 405 | 8 | 9 |
7 | 0.04 | 259 | 14.00 | 373 | 9 | 172 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 67.84 | 80 | 14.20 | 417 | 7 | |
2 | 66.52 | 25 | 14.53 | 418 | 7 | 7 |
3 | 33.32 | 25 | 14.58 | 374 | 7 | 7 |
4 | 0.08 | 25 | 14.70 | 326 | 7 | 7 |
5 | 0.16 | 276 | 14.33 | 316 | 8 |