SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8019 WMO= 5903535


Cycle 69 GMT 3/12/2012 18:34: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.52 36 14.23 500 7
2 113.88 -18 14.23 500 7
3 171.16 -17 14.23 500 7
4 305.12 70 11.27 784 7
5 69.28 25 13.87 490 7 7
6 -0.00 25 14.26 391 7 7
7 -0.00 194 14.11 372 7

Cycle 68 GMT 23/11/2012 21: 7: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.16 36 14.17 519 7 15
2 2007.88 70 10.16 2875 15 6
3 1812.64 24 12.01 2765 6 6
4 1380.16 24 12.43 2274 6 6
5 912.88 24 12.95 1663 6 7
6 199.80 24 13.77 732 7 8
7 99.48 24 13.98 584 7 7
8 20.96 24 14.21 449 7 7
9 0.12 25 14.36 393 7 9
10 0.04 179 14.12 388 7

Cycle 67 GMT 13/11/2012 21: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 36 14.17 500 7
2 2006.32 70 10.23 2888 6
3 1804.76 24 11.98 2791 6 6
4 1591.88 24 12.27 2516 6 6
5 860.32 24 12.95 1622 6 7
6 177.56 24 13.82 709 7 8
7 95.16 24 14.04 566 7 7
8 18.96 24 14.22 438 7 7
9 0.32 201 14.10 394 7 15

Cycle 66 GMT 3/11/2012 21:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.12 36 14.17 519 7 19
2 2010.80 70 10.18 2968 19 6
3 1812.36 24 12.03 2780 6 6
4 1372.08 24 12.48 2247 6 6
5 898.60 24 12.96 1655 6 7
6 193.20 24 13.79 716 7 8
7 89.64 24 13.99 570 7 7
8 20.20 24 14.21 449 7 7
9 0.12 25 14.26 422 7 8
10 -0.00 181 14.07 389 7

Cycle 65 GMT 24/10/2012 21:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.64 36 14.17 500 7 22
2 2008.40 70 10.28 2885 22 6
3 1804.76 24 12.06 2722 6 6
4 1377.20 24 12.45 2266 6 6
5 909.04 24 12.97 1649 6 7
6 180.20 24 13.83 695 7 8
7 94.44 24 14.01 576 7 7
8 44.68 24 14.12 493 7 7
9 0.08 201 14.09 389 7 19

Cycle 64 GMT 14/10/2012 21:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.84 36 14.17 519 7
2 2007.28 70 10.29 2908 6
3 1810.00 24 12.11 2693 6 6
4 1383.28 24 12.47 2261 6 6
5 936.68 24 12.90 1703 6 7
6 217.72 24 13.78 732 7 8
7 108.64 24 14.00 570 7 7
8 52.12 24 14.15 494 7 7
9 -0.00 201 14.12 377 7 22

Cycle 63 GMT 4/10/2012 21:30: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.24 36 14.23 480 7
2 2008.84 70 10.31 2864 6
3 1836.56 24 12.05 2768 6 6
4 1405.68 24 12.48 2291 6 6
5 928.08 24 12.95 1678 6 7
6 199.72 24 13.79 740 7 8
7 106.80 24 13.99 591 7 7
8 22.80 24 14.22 447 7 7
9 0.12 25 14.32 403 7 7
10 0.04 181 14.09 386 7

Cycle 62 GMT 24/ 9/2012 21:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 36 14.10 519 7 34
2 2009.68 70 10.38 2889 34 6
3 1810.96 24 12.11 2724 6 6
4 1388.20 24 12.47 2268 6 6
5 712.36 24 13.15 1411 6 8
6 148.76 24 13.87 666 7 7
7 86.60 24 14.08 547 7 7
8 41.04 24 14.20 480 7 7
9 0.04 25 14.35 403 7 7
10 -0.00 181 14.10 384 7

Cycle 61 GMT 14/ 9/2012 21:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.76 36 14.17 500 8 16
2 2011.04 70 10.32 2940 16 6
3 1811.28 24 12.09 2764 6 6
4 1359.52 24 12.47 2265 6 6
5 680.52 24 13.18 1380 6 8
6 140.52 24 13.93 628 7 7
7 80.88 24 14.12 534 7 7
8 0.12 25 14.33 397 7 7
9 -0.00 201 14.13 363 7 34

Cycle 60 GMT 4/ 9/2012 21:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.28 36 14.17 519 7
2 2010.76 70 10.46 2871 6
3 1814.76 24 12.12 2739 6 6
4 1369.64 24 12.46 2282 6 6
5 909.40 24 12.96 1666 6 7
6 189.56 24 13.81 699 7 8
7 92.16 24 14.05 557 7 7
8 0.20 25 14.29 399 7 7
9 0.08 200 14.07 375 8 16

Cycle 59 GMT 25/ 8/2012 21:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.48 36 14.04 538 7 18
2 2007.52 70 10.37 2944 18 6
3 1813.56 24 12.12 2767 6 6
4 1599.64 24 12.33 2518 6 6
5 710.48 24 13.18 1401 6 8
6 144.08 24 13.88 647 7 7
7 82.24 24 14.08 545 7 7
8 39.20 24 14.23 464 7 7
9 0.04 25 14.35 399 7 7
10 -0.00 181 14.08 383 7

Cycle 58 GMT 15/ 8/2012 21:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.84 36 14.23 500 7
2 2009.40 70 10.42 2840 6
3 1804.24 24 12.10 2766 6 6
4 1363.88 24 12.53 2251 6 6
5 695.44 24 13.19 1391 6 8
6 236.36 24 13.73 786 7 8
7 108.68 24 14.01 591 7 8
8 0.12 25 14.35 407 7 7
9 0.04 201 14.06 372 7 18

Cycle 57 GMT 5/ 8/2012 21:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.52 36 14.17 519 7 19
2 2001.88 70 10.37 2878 19 6
3 1786.56 24 12.17 2688 6 6
4 1364.24 24 12.53 2245 6 6
5 697.64 24 13.22 1366 6 8
6 243.08 24 13.76 757 7 8
7 61.56 24 14.18 476 7 7
8 0.16 25 14.36 370 7 7
9 0.12 201 14.09 356 7

Cycle 56 GMT 26/ 7/2012 21:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.00 36 14.17 500 7 9
2 2002.08 70 10.14 3000 9 6
3 1825.64 24 12.11 2759 6 6
4 1382.84 24 12.53 2266 6 6
5 715.08 24 13.18 1401 6 8
6 141.20 24 13.91 647 7 7
7 77.36 24 14.12 534 7 7
8 0.08 25 14.33 403 7 7
9 0.04 201 14.05 374 7 19

Cycle 55 GMT 16/ 7/2012 21:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.08 36 14.10 500 7 11
2 2006.52 70 10.27 2813 11 6
3 1805.76 24 12.18 2720 6 6
4 1359.76 24 12.57 2261 6 6
5 876.08 24 13.00 1643 6 7
6 166.08 24 13.85 688 7 8
7 89.08 24 14.11 534 7 7
8 -0.00 201 14.11 370 7 9

Cycle 54 GMT 6/ 7/2012 21:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.76 36 14.10 519 7 16
2 2003.76 70 10.07 2902 16 6
3 1818.24 24 12.12 2749 6 6
4 1363.68 24 12.56 2251 6 6
5 707.00 24 13.24 1382 6 8
6 146.12 24 13.98 603 7 7
7 83.00 24 14.14 532 7 7
8 0.12 25 14.38 397 7 7
9 -0.00 201 14.11 360 7 11

Cycle 53 GMT 26/ 6/2012 21:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.60 36 14.17 519 7 13
2 2010.56 70 9.81 2946 13 6
3 1841.84 24 12.15 2745 6 6
4 1625.36 24 12.37 2522 6 6
5 920.36 24 13.01 1669 6 7
6 237.00 24 13.80 759 7 8
7 111.84 24 14.05 582 7 7
8 0.12 25 14.38 397 7 7
9 0.08 201 14.05 371 7 16

Cycle 52 GMT 16/ 6/2012 21:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.80 36 14.10 519 11 24
2 2004.00 70 9.90 2813 24 6
3 1807.52 24 12.18 2713 6 6
4 1380.72 24 12.56 2276 6 6
5 910.16 24 13.01 1674 6 7
6 206.60 24 13.81 716 7 8
7 110.88 24 14.05 587 7 7
8 0.12 25 14.40 403 7 9
9 0.08 200 14.08 376 7 13

Cycle 51 GMT 6/ 6/2012 21:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.00 36 14.10 519 7 12
2 2009.60 70 9.67 2910 12 6
3 1813.16 24 12.24 2664 6 6
4 1396.76 24 12.60 2264 6 6
5 947.76 24 12.98 1713 6 7
6 249.28 24 13.77 786 7 8
7 117.36 24 14.04 603 7 7
8 0.16 25 14.38 409 7 7
9 0.04 201 14.04 382 11 24

Cycle 50 GMT 27/ 5/2012 21:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.16 36 14.23 480 7 13
2 2005.96 70 9.68 2884 13 6
3 1815.92 24 12.27 2682 6 6
4 1392.08 24 12.58 2284 6 6
5 739.36 24 13.20 1445 6 8
6 270.92 24 13.75 816 7 8
7 131.08 24 14.05 618 7 8
8 0.16 25 14.39 403 7 7
9 0.04 201 14.06 376 7 12

Cycle 49 GMT 17/ 5/2012 21:18: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.16 36 14.23 500 7 13
2 2002.96 70 9.78 2865 13 6
3 1827.12 24 12.16 2770 6 6
4 1608.48 24 12.43 2539 6 6
5 937.80 24 13.05 1680 6 7
6 240.20 24 13.82 765 7 8
7 128.52 24 14.09 597 7 7
8 0.76 201 14.12 372 7 13

Cycle 48 GMT 7/ 5/2012 21:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.56 36 14.23 519 7 16
2 2009.64 70 9.87 2865 16 6
3 1819.36 24 12.27 2716 6 6
4 1390.00 24 12.62 2272 6 6
5 730.72 24 13.25 1436 6 8
6 168.20 24 14.00 651 7 7
7 93.52 24 14.19 536 7 7
8 0.16 25 14.42 392 7 7
9 0.08 200 14.13 366 7 13

Cycle 47 GMT 27/ 4/2012 21:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.88 36 14.23 500 7 13
2 2009.12 70 10.13 2835 13 6
3 1805.44 24 12.24 2740 6 6
4 1362.52 24 12.66 2249 6 6
5 708.40 24 13.28 1387 6 8
6 163.72 24 13.97 664 7 7
7 93.72 24 14.21 530 7 7
8 0.04 25 14.43 386 7 7
9 0.04 201 14.10 369 7 16

Cycle 46 GMT 17/ 4/2012 21: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.04 36 14.23 480 7 11
2 2000.92 70 10.11 2885 11 6
3 1808.96 24 12.22 2757 6 6
4 1603.88 24 12.48 2536 6 7
5 692.96 24 13.30 1374 6 8
6 240.40 24 13.84 769 7 8
7 116.32 24 14.12 568 7 7
8 0.08 25 14.42 397 7 7
9 -0.00 201 14.10 366 7 13

Cycle 45 GMT 7/ 4/2012 21: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 36 14.23 500 7 16
2 2013.56 70 10.34 2824 16 6
3 1827.84 24 12.24 2763 6 6
4 1615.76 24 12.45 2551 6 6
5 689.96 24 13.29 1386 6 8
6 236.08 24 13.87 759 7 8
7 116.12 24 14.13 570 7 7
8 0.12 25 14.43 384 7 8
9 0.04 201 14.11 362 7 11

Cycle 44 GMT 28/ 3/2012 21:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.92 36 14.23 480 7 17
2 2001.72 70 10.36 2850 17 6
3 1820.68 24 12.28 2747 6 6
4 1403.44 24 12.69 2274 6 6
5 947.24 24 13.09 1690 6 7
6 216.32 24 13.93 699 7 8
7 108.12 24 14.16 551 7 7
8 0.12 25 14.41 386 7 7
9 0.08 201 14.10 362 7 16

Cycle 43 GMT 18/ 3/2012 21:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 36 14.29 480 7
2 2008.76 70 10.41 2827 6
3 1807.12 24 12.37 2682 6 6
4 1588.12 24 12.60 2466 6 6
5 870.16 24 13.20 1595 6 7
6 397.76 24 13.68 962 7 8
7 92.08 24 14.17 528 7 7
8 0.08 25 14.40 393 7 9
9 0.08 201 14.11 358 7 17

Cycle 42 GMT 8/ 3/2012 21:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 36 14.29 500 7 27
2 2009.24 70 10.48 2939 27 6
3 1815.36 24 12.36 2703 6 6
4 1171.80 24 12.91 1999 6 7
5 724.00 24 13.36 1401 6 8
6 151.72 24 14.07 609 7 7
7 76.20 24 14.27 505 7 7
8 0.16 25 14.44 382 7 7
9 0.08 201 14.13 359 7

Cycle 41 GMT 27/ 2/2012 21:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.08 36 14.29 480 7 38
2 2013.08 70 10.68 2916 38 6
3 1819.96 24 12.41 2722 6 6
4 1394.44 24 12.74 2295 6 6
5 906.72 24 13.19 1655 6 7
6 182.28 24 14.00 678 7 8
7 90.16 24 14.22 528 7 7
8 0.12 25 14.43 391 7 7
9 -0.00 201 14.10 367 7 27

Cycle 40 GMT 17/ 2/2012 21:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.44 36 14.36 480 7
2 2006.88 70 10.83 2913 6
3 1804.00 24 12.45 2684 6 6
4 1148.40 24 12.97 1974 6 7
5 690.24 24 13.39 1359 6 8
6 145.68 24 14.11 601 7 7
7 72.04 24 14.30 487 7 7
8 0.16 25 14.47 384 7 7
9 0.12 201 14.17 357 7 38

Cycle 39 GMT 7/ 2/2012 21:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 36 14.29 500 7
2 2006.24 70 10.99 2958 6
3 1788.80 24 12.49 2712 6 6
4 1115.24 24 13.04 1920 6 7
5 461.16 24 13.66 1053 7 8
6 143.36 24 14.10 599 7 7
7 68.12 24 14.31 482 7 7
8 0.12 25 14.49 372 7 7
9 0.08 197 14.17 346 7

Cycle 38 GMT 28/ 1/2012 21:40: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.48 36 14.36 480 7
2 2002.00 70 11.31 2841 6
3 1790.52 24 12.50 2724 6 6
4 1142.56 24 13.05 1934 6 7
5 924.76 24 13.25 1663 6 8
6 176.84 24 14.03 655 7 8
7 87.80 24 14.26 507 7 7
8 0.04 25 14.46 376 7 7
9 0.04 201 14.15 349 7

Cycle 37 GMT 18/ 1/2012 21:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.88 35 14.36 480 7
2 2008.48 70 11.49 2811 6
3 1796.52 25 12.52 2718 6 6
4 1136.16 24 13.07 1926 6 7
5 470.12 24 13.66 1064 6 8
6 149.48 24 14.14 613 7 7
7 68.76 24 14.33 484 7 7
8 0.12 25 14.51 366 7 7
9 0.08 201 14.18 348 7

Cycle 36 GMT 8/ 1/2012 21:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.24 35 14.36 480 7 17
2 2004.76 70 11.62 2901 17 6
3 1795.80 24 12.59 2707 6 6
4 1082.20 24 13.13 1870 6 7
5 638.52 24 13.50 1291 6 8
6 160.40 24 14.13 613 7 7
7 75.76 24 14.32 482 7 7
8 0.04 25 14.49 370 7 12
9 -0.00 201 14.16 354 7

Cycle 35 GMT 29/12/2011 22: 3:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.04 35 14.42 461 7 8
2 2007.60 70 11.99 2645 8 6
3 1792.80 25 12.65 2686 6 6
4 1325.88 25 12.95 2178 6 7
5 640.60 24 13.51 1310 6 8
6 181.92 24 14.06 670 7 8
7 93.92 24 14.29 528 7 7
8 0.08 25 14.50 385 7 7
9 0.08 200 14.17 357 7 17

Cycle 34 GMT 19/12/2011 22:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.44 35 14.42 461 7 10
2 2011.24 70 12.03 2706 10 6
3 1793.96 25 12.65 2699 6 6
4 1112.60 25 13.13 1914 6 7
5 660.24 25 13.52 1338 6 8
6 122.52 24 14.25 551 7 7
7 62.04 24 14.37 468 7 7
8 0.32 201 14.23 349 7 8

Cycle 33 GMT 9/12/2011 22:30:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.12 35 14.42 461 7 8
2 2010.16 70 12.15 2640 8 6
3 1801.08 25 12.70 2676 6 6
4 1137.88 25 13.13 1957 6 7
5 669.64 25 13.51 1334 6 8
6 129.96 24 14.25 547 7 7
7 59.72 24 14.40 449 7 7
8 0.08 201 14.23 342 7 10

Cycle 32 GMT 29/11/2011 22:26:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.88 35 14.42 461 7 12
2 2008.04 70 12.11 2768 12 6
3 1571.52 25 12.83 2484 6 6
4 1113.12 25 13.19 1911 6 7
5 428.16 25 13.80 990 7 8
6 115.52 24 14.25 553 7 7
7 56.08 24 14.36 461 7 7
8 0.12 201 14.21 346 7 8

Cycle 31 GMT 19/11/2011 22:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.08 35 14.42 480 7
2 2000.92 70 12.12 2868 6
3 1576.76 25 12.88 2499 6 6
4 903.28 24 13.38 1628 6 7
5 438.36 24 13.80 1013 7 8
6 113.92 24 14.30 539 7 7
7 58.64 24 14.35 466 7 7
8 1.28 201 14.22 349 7 12

Cycle 30 GMT 9/11/2011 22:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.80 35 14.42 480 7
2 2010.44 81 12.06 2932 6
3 1546.36 25 12.91 2465 6 6
4 1080.64 24 13.24 1863 6 7
5 170.80 24 14.14 641 7 8
6 98.36 24 14.30 519 7 7
7 0.20 25 14.57 361 7 7
8 0.08 213 14.20 342 7

Cycle 29 GMT 30/10/2011 22:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.56 35 14.42 480 7
2 2011.92 81 12.16 2771 6
3 1561.40 25 12.94 2470 6 6
4 869.44 25 13.41 1591 6 7
5 183.72 25 14.14 659 7 8
6 99.36 24 14.28 536 7 7
7 0.08 240 14.18 355 7

Cycle 28 GMT 20/10/2011 21:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.76 35 14.42 461 7
2 2003.72 81 12.19 2801 6
3 1336.12 25 13.07 2201 6 6
4 882.00 25 13.45 1611 6 7
5 178.72 25 14.17 657 7 8
6 100.76 24 14.32 524 7 7
7 0.08 25 14.55 351 7 7
8 0.04 213 14.18 344 7

Cycle 27 GMT 10/10/2011 21: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.28 35 14.42 442 7
2 2010.36 81 12.39 2583 6
3 1578.96 25 12.96 2499 6 6
4 908.64 24 13.45 1637 6 7
5 431.96 24 13.87 986 6 8
6 105.48 24 14.32 515 7 7
7 0.16 24 14.58 355 7 7
8 0.12 224 14.20 341 7

Cycle 26 GMT 30/ 9/2011 20:34: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.44 35 14.42 442 7
2 2001.36 81 12.22 2809 6
3 1547.00 25 13.02 2449 6 6
4 833.36 25 13.50 1555 6 7
5 175.60 25 14.21 630 7 8
6 95.04 25 14.34 509 7 7
7 0.12 25 14.56 361 7 8
8 0.08 205 14.19 338 7

Cycle 25 GMT 20/ 9/2011 20: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.28 35 14.42 480 7
2 2009.56 81 12.23 2799 6
3 1567.20 25 12.99 2480 6 6
4 844.72 25 13.52 1540 6 7
5 179.08 25 14.21 622 7 8
6 85.72 25 14.36 488 7 7
7 0.12 25 14.55 351 7 7
8 0.04 208 14.16 343 7

Cycle 24 GMT 10/ 9/2011 19:38:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.68 35 14.36 480 7
2 2007.52 81 12.26 2729 6
3 1552.36 25 13.04 2470 6 6
4 1069.52 25 13.35 1857 6 7
5 176.12 25 14.18 641 7 8
6 90.84 25 14.33 519 7 7
7 -0.00 234 14.20 345 7

Cycle 23 GMT 31/ 8/2011 19: 7: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.48 35 14.42 461 7
2 2002.00 81 12.25 2819 6
3 1347.44 25 13.15 2222 6 6
4 683.56 25 13.65 1353 6 7
5 207.56 25 14.14 709 7 8
6 98.76 25 14.34 528 7 8
7 0.08 25 14.53 372 7 7
8 0.04 208 14.15 347 7

Cycle 22 GMT 21/ 8/2011 18:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.28 35 14.42 480 7
2 2011.08 81 12.25 2808 6
3 1567.12 25 13.04 2486 6 6
4 859.12 25 13.52 1582 6 7
5 164.84 25 14.25 613 7 8
6 91.20 25 14.36 501 7 7
7 0.12 25 14.57 349 7 8
8 0.08 210 14.18 345 7

Cycle 21 GMT 11/ 8/2011 17:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.96 35 14.42 480 7
2 2001.12 81 12.28 2796 6
3 1332.20 25 13.19 2184 6 7
4 661.24 24 13.67 1310 6 7
5 205.96 24 14.17 688 7 8
6 102.68 24 14.34 526 7 7
7 0.12 25 14.55 357 7 7
8 0.08 214 14.16 343 7

Cycle 20 GMT 1/ 8/2011 17:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.96 35 14.42 480 7
2 2010.08 81 12.26 2810 6
3 1555.04 24 13.04 2486 6 6
4 650.60 24 13.69 1310 6 7
5 206.36 24 14.19 678 7 8
6 98.76 24 14.33 526 7 7
7 0.20 237 14.19 351 7

Cycle 19 GMT 22/ 7/2011 16:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.76 35 14.42 461 7
2 2006.64 81 12.29 2808 6
3 1343.84 25 13.18 2222 6 6
4 653.08 25 13.71 1297 6 8
5 190.00 25 14.19 657 7 8
6 89.60 25 14.35 493 7 7
7 0.04 25 14.56 359 7 7
8 -0.04 208 14.15 342 7

Cycle 18 GMT 12/ 7/2011 16:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.12 35 14.42 480 7
2 2000.80 81 12.34 2703 6
3 1553.56 25 13.06 2472 6 6
4 851.80 25 13.52 1584 6 7
5 177.92 25 14.24 626 7 8
6 91.64 25 14.36 497 7 7
7 0.12 25 14.59 342 7 7
8 0.08 208 14.17 335 7

Cycle 17 GMT 2/ 7/2011 15:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 34 14.42 461 7
2 2011.84 81 12.36 2739 6
3 1351.24 25 13.18 2224 6 6
4 891.80 25 13.51 1626 6 7
5 178.96 25 14.23 651 7 8
6 88.20 25 14.36 505 7 7
7 0.04 25 14.56 382 7 7
8 -0.00 208 14.16 349 7

Cycle 16 GMT 22/ 6/2011 15: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.64 34 14.42 480 7
2 2006.76 81 12.35 2783 6
3 1350.36 25 13.19 2209 6 6
4 897.20 25 13.51 1630 6 7
5 176.24 24 14.25 634 7 8
6 85.08 24 14.38 491 7 7
7 -0.00 25 14.59 353 7 8
8 -0.00 208 14.16 346 7

Cycle 15 GMT 12/ 6/2011 14:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.56 34 14.42 500 7
2 2011.80 81 12.41 2733 6
3 1550.00 25 13.05 2490 6 6
4 850.56 25 13.55 1561 6 7
5 179.68 25 14.22 647 7 8
6 90.48 25 14.37 503 7 7
7 0.08 25 14.58 363 7 7
8 0.12 208 14.14 352 7

Cycle 14 GMT 2/ 6/2011 13:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.24 34 14.42 461 7
2 2010.12 81 12.39 2727 6
3 1554.12 25 13.07 2463 6 6
4 860.36 25 13.53 1582 6 7
5 170.60 25 14.25 624 7 8
6 88.08 25 14.38 501 7 7
7 0.08 25 14.60 368 7 8
8 -0.00 210 14.14 362 7

Cycle 13 GMT 23/ 5/2011 12:56: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 34 14.42 500 7
2 2010.08 81 12.44 2708 6
3 1547.36 25 13.09 2451 6 6
4 833.92 25 13.53 1553 6 7
5 164.64 25 14.25 618 7 7
6 86.92 25 14.38 495 7 7
7 0.04 25 14.62 357 7 10
8 -0.00 208 14.15 352 7

Cycle 12 GMT 13/ 5/2011 12:18: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.56 34 14.42 480 7
2 2005.76 81 12.52 2647 6
3 1552.12 25 13.08 2441 6 6
4 838.24 25 13.54 1543 6 7
5 182.68 25 14.22 647 7 7
6 89.64 25 14.37 517 7 7
7 0.08 25 14.58 382 7 7
8 0.12 213 14.13 358 7

Cycle 11 GMT 3/ 5/2011 11:41: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 33 14.42 480 7
2 2008.16 81 12.52 2649 6
3 1535.92 25 13.08 2428 6 6
4 833.88 25 13.56 1522 6 7
5 177.40 25 14.26 626 7 7
6 84.32 25 14.40 488 7 7
7 -0.00 25 14.65 347 7 7
8 -0.04 208 14.17 343 7

Cycle 10 GMT 23/ 4/2011 10:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 33 14.48 480 7
2 2006.48 81 12.89 2074 6
3 1801.56 25 12.91 2761 6 6
4 1131.28 25 13.32 1918 6 7
5 460.44 25 13.89 1022 7 7
6 118.08 25 14.37 543 7 7
7 0.08 25 14.66 357 7 7
8 -0.04 223 14.16 347 7

Cycle 9 GMT 13/ 4/2011 10: 7: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.80 33 14.48 480 7
2 2003.20 81 12.68 2595 6
3 1313.64 24 13.22 2155 6 6
4 861.00 24 13.54 1574 6 7
5 171.76 24 14.33 624 7 7
6 84.12 24 14.45 501 7 7
7 0.08 25 14.65 366 7 8
8 0.04 213 14.16 356 7

Cycle 8 GMT 12/ 4/2011 15: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.68 33 14.48 500 9
2 2005.88 81 12.93 2171 6
3 1798.80 25 12.98 2688 6 6
4 1108.96 25 13.33 1905 6 6
5 417.12 25 13.98 972 6 7
6 99.16 25 14.44 526 7 7
7 0.08 25 14.70 372 7 7
8 -0.00 227 14.16 359 7

Cycle 7 GMT 11/ 4/2011 20: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.08 33 14.42 500 7
2 1958.72 81 12.97 2099 6
3 1543.64 25 13.10 2401 6 6
4 1326.00 25 13.22 2141 6 6
5 601.88 25 13.76 1228 6 7
6 90.92 24 14.47 509 7 7
7 43.48 24 14.49 443 7 7
8 0.12 25 14.57 376 7 7
9 0.12 200 14.13 355 9

Cycle 6 GMT 11/ 4/2011 1:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 33 14.42 500 7
2 1955.60 81 13.08 1934 6
3 1777.08 25 12.96 2626 6 6
4 1348.80 25 13.14 2174 6 6
5 879.24 25 13.48 1614 6 7
6 172.64 25 14.24 676 7 7
7 36.16 25 14.50 461 7 7
8 0.04 24 14.51 389 7 8
9 0.08 211 14.07 369 7

Cycle 5 GMT 10/ 4/2011 6:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 33 14.42 500 7
2 1761.48 81 12.75 2522 6
3 1299.28 25 13.24 2088 6 6
4 595.88 25 13.73 1241 6 7
5 99.20 25 14.44 524 7 7
6 45.88 25 14.47 459 7 7
7 0.08 25 14.56 376 7 7
8 0.04 202 14.12 353 7

Cycle 4 GMT 9/ 4/2011 13:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 33 14.36 500 7
2 1755.24 81 12.85 2282 6
3 1342.36 25 13.16 2145 6 6
4 665.72 25 13.62 1314 6 7
5 126.92 24 14.36 560 7 7
6 64.56 24 14.40 484 7 7
7 -0.00 25 14.59 388 7 7
8 -0.00 210 14.09 358 7

Cycle 3 GMT 8/ 4/2011 19:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.32 32 14.42 480 7
2 1516.64 81 12.84 2268 6
3 1077.96 25 13.27 1870 6 6
4 370.56 25 13.92 938 6 7
5 76.76 25 14.40 515 7 7
6 0.04 245 14.11 368 7

Cycle 2 GMT 8/ 4/2011 7: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.08 34 14.29 500 7
2 951.56 -2 14.29 500 7
3 1501.88 81 12.80 2223 6
4 1070.56 25 13.20 1891 6 6
5 603.36 25 13.55 1309 6 7
6 85.84 25 14.33 507 7 7
7 0.12 25 14.59 376 7 9
8 0.04 221 14.05 352 7

Cycle 1 GMT 7/ 4/2011 18:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.20 25 14.55 461 7
2 1112.16 2 13.91 1961 7
3 1165.32 81 12.80 1942 7
4 160.84 25 14.07 686 7 7
5 35.28 25 14.35 466 7 7
6 -0.00 25 14.36 409 7 7
7 -0.04 215 13.96 371 7

Cycle 0 GMT 7/ 4/2011 10:43: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 92.32 81 14.19 419 7
2 77.16 25 14.55 397 7 7
3 0.16 25 14.76 297 7 7
4 0.12 253 14.38 286 7