SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.88 | 45 | 14.42 | 423 | 7 | |
2 | 2011.64 | 81 | 12.31 | 2645 | 6 | |
3 | 1366.12 | 25 | 13.27 | 1972 | 6 | 6 |
4 | 1155.28 | 25 | 13.41 | 1741 | 6 | 7 |
5 | 691.96 | 24 | 13.73 | 1218 | 7 | 8 |
6 | 136.00 | 24 | 14.35 | 528 | 7 | 8 |
7 | 76.88 | 24 | 14.47 | 436 | 7 | 7 |
8 | 13.76 | 24 | 14.58 | 347 | 7 | 7 |
9 | -0.00 | 329 | 14.24 | 315 | 7 | 190 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.68 | 44 | 14.48 | 423 | 8 | 199 |
2 | 2011.00 | 81 | 12.32 | 2653 | 199 | 6 |
3 | 1365.08 | 24 | 13.27 | 1984 | 6 | 7 |
4 | 941.52 | 24 | 13.53 | 1526 | 7 | 7 |
5 | 721.52 | 24 | 13.72 | 1228 | 7 | 8 |
6 | 142.68 | 24 | 14.36 | 520 | 7 | 8 |
7 | 82.24 | 24 | 14.48 | 432 | 7 | 7 |
8 | 0.20 | 25 | 14.64 | 338 | 7 | 9 |
9 | 0.08 | 332 | 14.23 | 316 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.32 | 44 | 14.42 | 423 | 7 | 231 |
2 | 2009.00 | 81 | 12.35 | 2641 | 231 | 6 |
3 | 1556.36 | 25 | 13.19 | 2162 | 6 | 6 |
4 | 914.68 | 25 | 13.56 | 1499 | 7 | 7 |
5 | 477.64 | 24 | 13.95 | 936 | 7 | 8 |
6 | 137.60 | 24 | 14.37 | 513 | 7 | 8 |
7 | 77.28 | 24 | 14.45 | 442 | 7 | 7 |
8 | 0.12 | 25 | 14.65 | 335 | 7 | 8 |
9 | 0.08 | 326 | 14.21 | 319 | 8 | 199 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.36 | 44 | 14.42 | 423 | 7 | 224 |
2 | 2011.72 | 81 | 12.38 | 2627 | 224 | 7 |
3 | 1790.92 | 25 | 13.13 | 2312 | 6 | 6 |
4 | 1111.28 | 25 | 13.43 | 1711 | 6 | 7 |
5 | 657.36 | 25 | 13.78 | 1157 | 7 | 8 |
6 | 113.88 | 24 | 14.40 | 488 | 7 | 7 |
7 | 67.68 | 24 | 14.47 | 426 | 7 | 7 |
8 | 0.12 | 25 | 14.65 | 332 | 7 | 8 |
9 | 0.16 | 326 | 14.23 | 316 | 7 | 231 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 44 | 14.48 | 423 | 7 | 240 |
2 | 2005.64 | 81 | 12.39 | 2618 | 240 | 6 |
3 | 1390.52 | 25 | 13.28 | 1965 | 6 | 7 |
4 | 968.64 | 25 | 13.52 | 1553 | 7 | 7 |
5 | 511.32 | 24 | 13.91 | 968 | 7 | 8 |
6 | 135.80 | 24 | 14.35 | 519 | 7 | 8 |
7 | 71.44 | 24 | 14.46 | 434 | 7 | 7 |
8 | 0.12 | 25 | 14.63 | 334 | 7 | 8 |
9 | -0.00 | 324 | 14.20 | 319 | 7 | 224 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.20 | 44 | 14.42 | 442 | 7 | 168 |
2 | 2001.52 | 81 | 12.43 | 2571 | 168 | 7 |
3 | 1559.36 | 25 | 13.18 | 2180 | 7 | 6 |
4 | 1106.68 | 25 | 13.41 | 1720 | 6 | 7 |
5 | 641.24 | 25 | 13.79 | 1132 | 7 | 8 |
6 | 119.16 | 24 | 14.45 | 490 | 7 | 7 |
7 | 68.64 | 24 | 14.51 | 430 | 7 | 7 |
8 | 0.12 | 25 | 14.68 | 339 | 7 | 7 |
9 | 0.12 | 326 | 14.25 | 315 | 7 | 240 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.20 | 44 | 14.42 | 423 | 8 | 254 |
2 | 2000.76 | 81 | 12.46 | 2554 | 254 | 7 |
3 | 1565.76 | 25 | 13.17 | 2178 | 6 | 7 |
4 | 1104.52 | 24 | 13.43 | 1676 | 7 | 7 |
5 | 411.00 | 24 | 14.01 | 865 | 7 | 8 |
6 | 134.80 | 24 | 14.42 | 513 | 7 | 7 |
7 | 72.80 | 24 | 14.53 | 428 | 7 | 7 |
8 | 0.16 | 25 | 14.67 | 334 | 7 | 8 |
9 | 0.08 | 326 | 14.24 | 317 | 7 | 168 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.88 | 44 | 14.42 | 423 | 7 | 170 |
2 | 2011.52 | 81 | 12.46 | 2605 | 170 | 7 |
3 | 1563.52 | 25 | 13.19 | 2139 | 6 | 6 |
4 | 931.20 | 25 | 13.52 | 1515 | 6 | 7 |
5 | 493.08 | 24 | 13.92 | 972 | 7 | 8 |
6 | 134.76 | 24 | 14.37 | 528 | 7 | 7 |
7 | 69.68 | 24 | 14.51 | 422 | 7 | 7 |
8 | 0.12 | 25 | 14.66 | 341 | 7 | 7 |
9 | 0.12 | 324 | 14.20 | 320 | 8 | 254 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.84 | 42 | 14.48 | 423 | 7 | 153 |
2 | 1048.44 | 1 | 14.48 | 1596 | 7 | 153 |
3 | 2000.76 | 81 | 12.47 | 2626 | 153 | 6 |
4 | 1539.12 | 25 | 13.18 | 2132 | 6 | 6 |
5 | 874.48 | 25 | 13.58 | 1430 | 6 | 7 |
6 | 440.60 | 25 | 13.99 | 886 | 7 | 8 |
7 | 115.92 | 24 | 14.42 | 497 | 7 | 7 |
8 | 57.64 | 24 | 14.50 | 416 | 7 | 7 |
9 | 0.12 | 25 | 14.67 | 335 | 9 | 7 |
10 | 0.04 | 321 | 14.19 | 319 | 7 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 42 | 14.48 | 423 | 7 | 173 |
2 | 2006.24 | 81 | 12.54 | 2615 | 173 | 6 |
3 | 1563.76 | 25 | 13.22 | 2126 | 6 | 7 |
4 | 1120.08 | 24 | 13.41 | 1703 | 7 | 7 |
5 | 447.92 | 24 | 13.97 | 895 | 7 | 8 |
6 | 125.20 | 24 | 14.40 | 507 | 7 | 7 |
7 | 68.72 | 24 | 14.49 | 432 | 7 | 7 |
8 | 0.12 | 25 | 14.65 | 333 | 7 | 7 |
9 | 0.08 | 326 | 14.18 | 318 | 7 | 153 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.12 | 42 | 14.48 | 403 | 7 | 205 |
2 | 1961.36 | 81 | 12.62 | 2571 | 205 | 7 |
3 | 1494.96 | 25 | 13.27 | 2074 | 6 | 7 |
4 | 837.92 | 25 | 13.66 | 1349 | 7 | 7 |
5 | 385.92 | 25 | 14.08 | 830 | 7 | 8 |
6 | 99.48 | 24 | 14.51 | 451 | 7 | 7 |
7 | 49.64 | 24 | 14.56 | 382 | 7 | 7 |
8 | 1.00 | 342 | 14.23 | 302 | 7 | 173 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.88 | 40 | 14.48 | 423 | 7 | 152 |
2 | 1042.04 | 1 | 14.48 | 1596 | 7 | 152 |
3 | 1958.92 | 81 | 12.66 | 2547 | 152 | 6 |
4 | 1497.80 | 24 | 13.19 | 2097 | 6 | 7 |
5 | 1038.24 | 24 | 13.45 | 1618 | 7 | 7 |
6 | 373.36 | 24 | 14.10 | 810 | 7 | 7 |
7 | 100.40 | 24 | 14.52 | 447 | 7 | 7 |
8 | 49.96 | 24 | 14.57 | 378 | 7 | 7 |
9 | 0.16 | 345 | 14.24 | 297 | 7 | 205 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 39 | 14.48 | 423 | 8 | 158 |
2 | 1753.00 | 81 | 12.77 | 2367 | 158 | 6 |
3 | 1537.32 | 25 | 13.20 | 2107 | 6 | 6 |
4 | 863.96 | 25 | 13.61 | 1364 | 6 | 7 |
5 | 218.84 | 25 | 14.27 | 622 | 7 | 7 |
6 | 119.48 | 25 | 14.42 | 493 | 7 | 7 |
7 | 0.16 | 25 | 14.70 | 330 | 7 | 7 |
8 | 0.16 | 337 | 14.18 | 309 | 7 | 152 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.84 | 34 | 14.55 | 403 | 9 | 163 |
2 | 1144.68 | 3 | 14.42 | 1711 | 9 | 163 |
3 | 1069.44 | 1 | 14.55 | 1653 | 9 | 163 |
4 | 1758.44 | 81 | 12.71 | 2425 | 163 | 6 |
5 | 1114.56 | 25 | 13.34 | 1738 | 6 | 7 |
6 | 686.48 | 25 | 13.73 | 1186 | 7 | 8 |
7 | 217.08 | 25 | 14.23 | 632 | 7 | 8 |
8 | 54.96 | 24 | 14.54 | 407 | 7 | 7 |
9 | 0.16 | 25 | 14.63 | 336 | 7 | 7 |
10 | 0.16 | 305 | 14.14 | 311 | 8 | 158 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 34 | 14.48 | 403 | 8 | 164 |
2 | 1146.92 | 3 | 14.36 | 1730 | 8 | 164 |
3 | 1501.56 | 80 | 12.85 | 2159 | 164 | 7 |
4 | 1284.56 | 25 | 13.23 | 1936 | 7 | 7 |
5 | 585.36 | 25 | 13.79 | 1074 | 7 | 8 |
6 | 153.96 | 25 | 14.33 | 536 | 7 | 8 |
7 | 76.16 | 25 | 14.45 | 432 | 7 | 8 |
8 | 0.16 | 25 | 14.64 | 330 | 8 | 8 |
9 | -0.00 | 302 | 14.12 | 311 | 9 | 163 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 32 | 14.42 | 442 | 10 | 202 |
2 | 1061.88 | 1 | 14.36 | 1826 | 10 | 202 |
3 | 1502.28 | 81 | 12.83 | 2109 | 202 | 7 |
4 | 1298.56 | 25 | 13.17 | 1909 | 6 | 7 |
5 | 603.88 | 25 | 13.69 | 1120 | 7 | 8 |
6 | 159.20 | 25 | 14.28 | 545 | 7 | 8 |
7 | 79.80 | 25 | 14.40 | 440 | 7 | 8 |
8 | 0.12 | 25 | 14.60 | 328 | 7 | 8 |
9 | 0.08 | 305 | 14.10 | 307 | 8 | 164 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.60 | 25 | 14.61 | 403 | 7 | |
2 | 1137.12 | 3 | 13.85 | 1884 | 7 | |
3 | 1192.00 | 80 | 12.81 | 1916 | 7 | |
4 | 163.52 | 25 | 14.16 | 589 | 8 | 10 |
5 | 36.68 | 25 | 14.44 | 395 | 7 | 9 |
6 | 0.12 | 25 | 14.47 | 341 | 8 | 11 |
7 | 0.16 | 250 | 14.06 | 318 | 10 | 202 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 117.88 | 81 | 14.20 | 419 | 7 | |
2 | 122.24 | 25 | 14.54 | 422 | 7 | 7 |
3 | 75.36 | 25 | 14.65 | 368 | 7 | 7 |
4 | 0.28 | 25 | 14.75 | 286 | 7 | 7 |
5 | 0.16 | 269 | 14.42 | 266 | 7 |