SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 3041 WMO= 5903881


Cycle 94 GMT 15/ 8/2014 4:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.52 340 14.29 115 0 4
2 2002.44 201 13.48 699 0 4
3 1918.28 101 13.40 653 0 0
4 1729.96 101 13.59 576 0 0
5 1545.92 100 13.65 538 0 0
6 1248.68 100 13.72 461 0 0
7 876.28 100 14.04 307 0 0
8 605.52 100 14.10 230 0 0
9 330.60 100 14.29 153 0 0
10 34.16 47 14.55 76 0 100

Cycle 93 GMT 5/ 8/2014 2: 7:17

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.84 342 14.29 115 0 4
2 996.12 -2 14.29 76 0 0
3 2002.68 201 13.49 700 0 4
4 1919.68 100 13.40 653 0 0
5 1734.28 100 13.46 615 0 0
6 1452.36 100 13.59 538 0 0
7 1178.44 100 13.72 461 0 0
8 900.80 100 13.97 307 0 0
9 627.92 100 14.10 230 0 0
10 260.84 100 14.29 192 0 0
11 6.64 42 14.55 76 0 100

Cycle 92 GMT 25/ 7/2014 23:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.48 343 14.48 115 0 4
2 995.36 -2 14.42 76 0 0
3 2003.08 201 13.51 697 0 4
4 1922.24 100 13.53 615 0 0
5 1744.00 100 13.40 653 0 0
6 1457.92 100 13.65 500 0 0
7 1179.88 100 13.78 423 0 0
8 902.52 100 13.97 346 0 0
9 628.28 100 14.17 230 0 0
10 264.52 100 14.48 115 0 0
11 40.88 44 14.61 76 0 100

Cycle 91 GMT 15/ 7/2014 21:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.04 343 14.36 115 0 4
2 2000.68 201 13.50 700 0 4
3 1912.88 101 13.40 653 0 0
4 1736.64 101 13.59 576 0 0
5 1377.08 100 13.65 500 0 0
6 1200.24 100 13.78 461 0 0
7 837.12 100 13.97 307 0 0
8 656.28 100 13.97 269 0 0
9 271.72 100 14.23 153 0 0
10 41.68 44 14.42 76 0 100

Cycle 90 GMT 5/ 7/2014 19:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 345 14.48 115 0 4
2 995.20 -2 14.29 76 0 0
3 2002.40 201 13.51 696 0 4
4 1923.24 101 13.40 653 0 0
5 1742.44 101 13.59 576 0 0
6 1556.92 100 13.59 538 0 0
7 1268.88 100 13.78 461 0 0
8 905.48 100 13.91 346 0 0
9 627.88 100 14.23 230 0 0
10 259.92 100 14.36 153 0 0
11 36.16 49 14.61 76 0 100

Cycle 89 GMT 25/ 6/2014 17:33:56

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.36 343 14.36 115 0 4
2 1006.40 2 14.29 384 0 0
3 2005.88 201 13.53 695 0 4
4 1920.48 101 13.59 615 0 0
5 1831.88 101 13.46 615 0 0
6 1452.92 100 13.65 538 0 0
7 1365.00 100 13.78 461 0 0
8 975.60 100 14.04 346 0 0
9 686.00 100 14.17 269 0 0
10 305.76 100 14.36 153 0 0
11 -0.20 49 14.61 76 0 100

Cycle 88 GMT 15/ 6/2014 15:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.40 345 14.36 115 0 4
2 992.64 -2 14.48 76 0 0
3 2007.52 201 13.53 701 0 4
4 1922.56 101 13.53 615 0 0
5 1749.04 101 13.59 576 0 0
6 1470.40 100 13.78 500 0 0
7 1189.28 100 13.78 423 0 0
8 998.72 100 13.85 384 0 0
9 621.00 100 14.10 230 0 0
10 252.08 100 14.36 153 0 0
11 3.12 45 14.80 76 0 100

Cycle 87 GMT 5/ 6/2014 13:28:55

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.28 342 14.42 115 0 4
2 1009.76 2 13.91 423 0 0
3 2001.52 201 13.55 690 0 4
4 1913.88 101 13.53 653 0 0
5 1726.00 101 13.59 576 0 0
6 1443.76 100 13.78 500 0 0
7 1260.16 100 13.78 423 0 0
8 966.36 100 13.97 346 0 0
9 674.64 100 14.17 230 0 0
10 301.28 100 14.36 153 0 0
11 28.04 44 14.48 76 0 100

Cycle 86 GMT 26/ 5/2014 11:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 342 14.48 76 0 4
2 2001.36 201 13.55 693 0 4
3 1915.84 101 13.40 692 0 0
4 1647.56 100 13.59 538 0 0
5 1475.92 100 13.65 500 0 0
6 1200.96 100 13.72 461 0 0
7 932.16 100 14.04 307 0 0
8 657.68 100 14.10 269 0 0
9 193.56 100 14.42 115 0 0
10 24.28 41 14.68 76 0 100

Cycle 85 GMT 16/ 5/2014 9:27:13

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 342 14.48 115 0 4
2 2001.16 201 13.56 692 0 4
3 1912.96 100 13.40 653 0 0
4 1642.88 100 13.72 538 0 0
5 1460.32 100 13.65 538 0 0
6 1183.36 100 13.85 423 0 0
7 998.04 100 13.91 346 0 0
8 706.76 100 13.97 269 0 0
9 312.56 100 14.36 153 0 0
10 61.20 47 14.55 76 0 100

Cycle 84 GMT 6/ 5/2014 7:25:54

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 342 14.48 115 0 4
2 2003.76 201 13.56 692 0 4
3 1921.92 101 13.46 653 0 0
4 1739.72 101 13.53 615 0 0
5 1462.76 100 13.72 500 0 0
6 1182.36 100 13.85 423 0 0
7 911.12 100 13.91 346 0 0
8 630.48 100 14.10 269 0 0
9 333.88 100 14.42 153 0 0
10 68.32 44 14.36 115 0 100

Cycle 83 GMT 26/ 4/2014 5:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.96 340 14.23 115 0 4
2 1006.64 2 14.04 423 0 0
3 2006.20 201 13.56 692 0 4
4 1913.84 101 13.40 653 0 0
5 1648.60 100 13.65 576 0 0
6 1472.88 100 13.78 500 0 0
7 1189.60 100 13.97 384 0 0
8 1005.24 100 13.91 384 0 0
9 720.52 100 14.04 269 0 0
10 327.16 100 14.42 153 0 0
11 64.56 45 14.48 115 0 100

Cycle 82 GMT 16/ 4/2014 3:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 340 14.42 115 0 4
2 2005.04 201 13.57 690 0 4
3 1927.88 101 13.46 653 0 0
4 1747.68 101 13.53 615 0 0
5 1384.72 100 13.65 500 0 0
6 1203.00 100 13.85 423 0 0
7 838.24 100 14.04 307 0 0
8 751.52 100 14.04 269 0 0
9 261.56 100 14.36 153 0 0
10 38.48 44 14.48 76 0 100

Cycle 81 GMT 6/ 4/2014 1:20: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.68 342 14.36 115 0 4
2 994.00 -2 14.42 76 0 0
3 2002.12 201 13.57 698 0 4
4 1916.32 101 13.53 653 0 0
5 1741.28 101 13.46 653 0 0
6 1453.96 100 13.72 500 0 0
7 1273.00 100 13.85 423 0 0
8 978.48 100 13.97 346 0 0
9 687.64 100 14.10 269 0 0
10 395.20 100 14.36 192 0 0
11 52.92 45 14.55 76 0 100

Cycle 80 GMT 26/ 3/2014 23:37:47

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.48 342 14.42 115 0 4
2 2002.44 201 13.58 696 0 4
3 1922.12 101 13.46 653 0 0
4 1648.12 100 13.59 576 0 0
5 1468.92 100 13.72 538 0 0
6 1186.52 100 13.91 384 0 0
7 907.92 100 13.97 346 0 0
8 726.72 100 14.10 307 0 0
9 244.68 100 14.29 153 0 0
10 73.04 41 14.55 76 0 100

Cycle 79 GMT 16/ 3/2014 21:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.56 342 14.36 115 0 4
2 2001.24 201 13.59 692 0 4
3 1917.56 101 13.46 653 0 0
4 1738.76 101 13.65 576 0 0
5 1550.00 100 13.65 538 0 0
6 1250.32 100 13.78 461 0 0
7 958.56 100 13.97 346 0 0
8 667.36 100 14.23 269 0 0
9 364.64 100 14.29 192 0 0
10 39.72 44 14.68 76 0 100

Cycle 78 GMT 6/ 3/2014 19:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.40 342 14.36 115 0 4
2 2001.52 201 13.59 690 0 4
3 1920.64 100 13.46 653 0 0
4 1834.12 100 13.53 615 0 0
5 1451.44 100 13.78 500 0 0
6 1176.40 100 13.85 423 0 0
7 902.88 100 14.04 307 0 0
8 623.00 100 14.10 230 0 0
9 236.68 100 14.36 153 0 0
10 69.72 41 14.42 115 0 100

Cycle 77 GMT 24/ 2/2014 17:59: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.76 342 14.36 115 0 4
2 2001.64 201 13.60 695 0 4
3 1921.08 101 13.40 692 0 0
4 1835.12 101 13.59 615 0 0
5 1448.36 100 13.72 500 0 0
6 1262.40 100 13.72 461 0 0
7 886.32 100 13.91 346 0 0
8 694.48 100 14.10 269 0 0
9 306.08 100 14.36 153 0 0
10 53.68 45 14.55 76 0 100

Cycle 76 GMT 14/ 2/2014 15:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 342 14.42 115 0 4
2 2002.24 201 13.60 692 0 4
3 1920.36 101 13.46 653 0 0
4 1736.72 101 13.53 615 0 0
5 1555.08 100 13.65 538 0 0
6 1257.96 100 13.72 461 0 0
7 965.76 100 14.04 346 0 0
8 673.36 100 14.17 269 0 0
9 289.36 100 14.48 115 0 0
10 43.84 44 14.42 76 0 100

Cycle 75 GMT 4/ 2/2014 14: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.32 342 14.42 115 0 4
2 2005.48 201 13.59 697 0 4
3 1919.96 101 13.53 653 0 0
4 1740.76 101 13.59 615 0 0
5 1461.28 100 13.72 500 0 0
6 1180.76 100 13.85 423 0 0
7 906.00 100 13.97 346 0 0
8 724.16 100 14.10 269 0 0
9 322.08 100 14.42 153 0 0
10 32.68 44 14.74 76 0 100

Cycle 74 GMT 25/ 1/2014 11:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.88 342 14.36 115 0 4
2 2001.12 201 13.60 700 0 4
3 1918.72 101 13.53 653 0 0
4 1737.48 101 13.65 576 0 0
5 1467.24 100 13.78 500 0 0
6 1190.64 100 13.97 423 0 0
7 915.96 100 13.97 346 0 0
8 638.12 100 14.10 269 0 0
9 344.64 100 14.29 153 0 0
10 18.24 44 14.68 76 0 100

Cycle 73 GMT 15/ 1/2014 10: 1: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.52 342 14.48 115 0 4
2 2003.92 201 13.62 695 0 4
3 1925.72 101 13.46 692 0 0
4 1744.12 101 13.59 615 0 0
5 1457.76 100 13.72 538 0 0
6 1178.36 100 13.91 423 0 0
7 994.12 100 14.04 346 0 0
8 605.16 100 14.23 230 0 0
9 322.24 100 14.29 192 0 0
10 60.84 41 14.48 115 0 100

Cycle 72 GMT 5/ 1/2014 8:10: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.52 342 14.29 115 0 4
2 2002.32 201 13.62 694 0 4
3 1921.48 101 13.46 692 0 0
4 1737.96 101 13.72 576 0 0
5 1467.60 100 13.78 500 0 0
6 1195.20 100 13.85 423 0 0
7 916.60 100 14.04 346 0 0
8 634.24 100 14.10 269 0 0
9 255.92 100 14.48 153 0 0
10 38.84 42 14.68 76 0 100

Cycle 71 GMT 26/12/2013 6:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.16 340 14.36 115 0 4
2 1006.64 2 14.42 384 0 0
3 2005.80 201 13.61 700 0 4
4 1918.44 101 13.53 653 0 0
5 1732.68 101 13.65 576 0 0
6 1453.56 100 13.78 500 0 0
7 1182.64 100 13.91 423 0 0
8 906.56 100 14.04 307 0 0
9 619.92 100 14.29 230 0 0
10 243.88 100 14.29 153 0 0
11 7.52 39 14.68 76 0 100

Cycle 70 GMT 16/12/2013 4: 6:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 340 14.36 115 0 4
2 2001.84 201 13.61 701 0 4
3 1919.92 101 13.46 692 0 0
4 1830.96 101 13.53 653 0 0
5 1441.52 100 13.72 538 0 0
6 1171.56 100 13.85 423 0 0
7 892.36 100 13.97 346 0 0
8 710.52 100 14.17 269 0 0
9 223.08 100 14.42 115 0 0
10 2.44 41 14.55 76 0 100

Cycle 69 GMT 6/12/2013 2:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 337 14.48 76 0 4
2 1015.76 2 14.36 423 0 0
3 2007.12 201 13.63 698 0 4
4 1928.12 101 13.46 653 0 0
5 1838.16 101 13.59 615 0 0
6 1443.36 100 13.72 538 0 0
7 1174.80 100 13.85 423 0 0
8 988.68 100 13.97 346 0 0
9 693.56 100 14.10 269 0 0
10 223.68 100 14.29 153 0 0
11 31.52 42 14.55 76 0 100

Cycle 68 GMT 26/11/2013 0:12:56

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.48 335 14.48 76 0 4
2 1012.08 2 14.42 384 0 0
3 2001.72 201 13.63 700 0 4
4 1912.64 101 13.53 653 0 0
5 1732.72 101 13.59 615 0 0
6 1459.72 100 13.78 500 0 0
7 1188.56 100 13.91 423 0 0
8 915.56 100 13.97 307 0 0
9 635.08 100 14.29 230 0 0
10 260.80 100 14.48 153 0 0
11 38.32 41 14.61 76 0 100

Cycle 67 GMT 15/11/2013 22: 3:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.20 337 14.23 115 0 4
2 984.76 -2 14.36 115 0 0
3 2003.56 201 13.63 699 0 4
4 1915.96 101 13.46 653 0 0
5 1826.28 101 13.65 576 0 0
6 1429.40 100 13.72 500 0 0
7 1152.28 100 13.91 384 0 0
8 962.36 100 14.10 307 0 0
9 668.52 100 14.10 269 0 0
10 290.88 100 14.17 153 0 0
11 0.96 43 14.61 76 0 100

Cycle 66 GMT 5/11/2013 20:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.24 337 14.42 115 0 4
2 2005.64 201 13.63 706 0 4
3 1924.16 101 13.46 653 0 0
4 1835.68 101 13.59 653 0 0
5 1438.12 100 13.72 538 0 0
6 1076.72 100 13.91 384 0 0
7 899.32 100 14.04 346 0 0
8 619.12 100 14.17 230 0 0
9 333.20 100 14.42 153 0 0
10 64.00 42 14.61 115 0 100

Cycle 65 GMT 26/10/2013 18: 5:33

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.88 338 14.42 115 0 4
2 994.00 -2 14.42 76 0 0
3 2002.24 201 13.63 706 0 4
4 1921.12 101 13.53 692 0 0
5 1643.64 100 13.65 615 0 0
6 1556.36 100 13.72 538 0 0
7 1268.48 100 13.85 461 0 0
8 891.60 100 13.97 346 0 0
9 523.52 100 14.17 230 0 0
10 260.24 100 14.42 153 0 0
11 91.40 44 14.61 76 0 100

Cycle 64 GMT 16/10/2013 15:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.16 340 14.36 115 0 4
2 989.88 -2 14.61 76 0 0
3 2002.84 201 13.65 705 0 4
4 1916.08 101 13.53 692 0 0
5 1733.28 101 13.59 615 0 0
6 1373.92 100 13.78 500 0 0
7 1191.20 100 13.91 423 0 0
8 1101.52 100 13.85 423 0 0
9 695.96 100 14.23 269 0 0
10 411.76 100 14.36 192 0 0
11 12.44 42 14.55 76 0 100

Cycle 63 GMT 6/10/2013 13:35:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.96 338 14.42 115 0 4
2 1008.48 2 14.29 423 0 0
3 2001.24 201 13.66 699 0 4
4 1914.44 101 13.46 653 0 0
5 1641.88 100 13.72 538 0 0
6 1378.92 100 13.85 461 0 0
7 1115.76 100 14.04 384 0 0
8 846.20 100 14.04 307 0 0
9 667.08 100 14.17 269 0 0
10 289.04 100 14.36 153 0 0
11 20.72 37 14.55 76 0 100

Cycle 62 GMT 26/ 9/2013 11:25:52

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.08 338 14.42 115 0 4
2 2008.96 201 13.67 698 0 4
3 1925.16 101 13.59 653 0 0
4 1739.24 101 13.65 615 0 0
5 1453.72 100 13.85 500 0 0
6 1179.36 100 13.97 384 0 0
7 991.32 100 13.97 346 0 0
8 699.00 100 14.17 269 0 0
9 310.16 100 14.36 192 0 0
10 13.76 39 14.55 76 0 100

Cycle 61 GMT 16/ 9/2013 9:13:35

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 338 14.42 115 0 4
2 2002.64 201 13.66 694 0 4
3 1921.04 100 13.53 653 0 0
4 1647.40 100 13.72 576 0 0
5 1460.68 100 13.72 500 0 0
6 1174.84 100 13.91 423 0 0
7 897.76 100 14.10 307 0 0
8 627.00 100 14.17 269 0 0
9 240.52 100 14.29 153 0 0
10 76.24 36 14.55 76 0 100

Cycle 60 GMT 6/ 9/2013 7: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.36 338 14.42 115 0 4
2 2000.64 201 13.68 694 0 4
3 1909.64 100 13.53 653 0 0
4 1735.44 100 13.59 615 0 0
5 1447.84 100 13.78 500 0 0
6 1172.52 100 13.91 423 0 0
7 896.68 100 13.97 346 0 0
8 609.64 100 14.23 230 0 0
9 323.08 100 14.36 153 0 0
10 14.00 37 14.55 76 0 100

Cycle 59 GMT 27/ 8/2013 5: 6: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.88 340 14.29 115 0 4
2 993.04 -2 14.74 76 0 0
3 2002.08 201 13.67 700 0 4
4 1918.88 101 13.53 692 0 0
5 1737.76 101 13.59 615 0 0
6 1382.72 100 13.85 500 0 0
7 1117.92 100 13.97 384 0 0
8 937.52 100 14.04 346 0 0
9 650.16 100 14.23 269 0 0
10 265.12 100 14.42 153 0 0
11 0.72 36 14.61 76 0 100

Cycle 58 GMT 17/ 8/2013 3:11: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.68 340 14.42 115 0 4
2 2003.40 201 13.69 691 0 4
3 1917.56 101 13.59 615 0 0
4 1738.40 101 13.65 615 0 0
5 1452.64 100 13.72 500 0 0
6 1168.72 100 13.91 423 0 0
7 895.36 100 14.10 346 0 0
8 530.32 100 14.29 230 0 0
9 249.52 100 14.42 153 0 0
10 5.24 34 14.68 76 0 100

Cycle 57 GMT 7/ 8/2013 1:19:51

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.84 338 14.48 115 0 4
2 1006.40 2 14.42 423 0 0
3 2000.92 201 13.70 695 0 4
4 1916.96 101 13.53 653 0 0
5 1741.44 101 13.72 576 0 0
6 1467.96 100 13.85 500 0 0
7 1180.40 100 13.91 423 0 0
8 813.04 100 14.04 346 0 0
9 631.32 100 14.29 230 0 0
10 249.92 100 14.48 153 0 0
11 34.96 32 14.55 115 0 100

Cycle 56 GMT 27/ 7/2013 23:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.84 338 14.42 115 0 4
2 2001.32 201 13.69 706 0 4
3 1918.04 101 13.53 692 0 0
4 1733.88 101 13.65 615 0 0
5 1447.44 100 13.85 500 0 0
6 1100.52 100 13.97 384 0 0
7 921.60 100 14.10 346 0 0
8 627.44 100 14.17 269 0 0
9 350.44 100 14.29 192 0 0
10 33.24 37 14.61 76 0 100

Cycle 55 GMT 17/ 7/2013 21:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.84 340 14.42 115 0 4
2 988.36 -2 14.74 76 0 0
3 2001.56 201 13.72 695 0 4
4 1920.36 101 13.53 653 0 0
5 1741.04 101 13.65 615 0 0
6 1383.52 100 13.85 500 0 0
7 1297.12 100 13.78 461 0 0
8 905.64 100 14.04 346 0 0
9 623.68 100 14.10 269 0 0
10 173.84 100 14.42 115 0 0
11 4.60 34 14.68 76 0 100

Cycle 54 GMT 7/ 7/2013 19:26:48

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.32 342 14.42 115 0 4
2 986.28 -2 14.61 76 0 0
3 2001.64 201 13.72 695 0 4
4 1917.36 101 13.53 653 0 0
5 1643.28 100 13.78 576 0 0
6 1469.40 100 13.78 538 0 0
7 1192.44 100 13.91 423 0 0
8 902.84 100 14.10 346 0 0
9 708.04 100 14.17 269 0 0
10 227.00 100 14.48 153 0 0
11 32.16 31 14.74 76 0 100

Cycle 53 GMT 27/ 6/2013 17:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.84 340 14.42 115 0 4
2 1006.12 2 14.55 384 0 0
3 2001.08 201 13.73 690 0 4
4 1907.76 101 13.59 653 0 0
5 1718.68 101 13.72 615 0 0
6 1442.16 100 13.72 500 0 0
7 1164.76 100 13.91 461 0 0
8 887.84 100 13.97 346 0 0
9 611.32 100 14.23 269 0 0
10 218.28 100 14.48 115 0 0
11 60.88 27 14.55 76 0 100

Cycle 52 GMT 17/ 6/2013 15:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.84 338 14.42 115 0 4
2 1004.60 2 14.48 423 0 0
3 2001.96 201 13.74 693 0 4
4 1916.96 101 13.59 653 0 0
5 1735.88 101 13.65 615 0 0
6 1456.52 100 13.91 500 0 0
7 1181.52 100 13.91 423 0 0
8 896.28 100 14.10 346 0 0
9 617.68 100 14.36 230 0 0
10 231.00 100 14.55 115 0 0
11 3.68 29 14.74 76 0 100

Cycle 51 GMT 7/ 6/2013 13:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.12 340 14.55 115 0 4
2 994.20 -2 14.80 76 0 0
3 2000.64 201 13.74 696 0 4
4 1914.56 101 13.65 615 0 0
5 1641.24 100 13.72 576 0 0
6 1465.52 100 13.85 538 0 0
7 1177.00 100 14.04 384 0 0
8 896.44 100 14.10 346 0 0
9 614.68 100 14.23 269 0 0
10 236.72 100 14.55 115 0 0
11 30.00 29 14.55 76 0 100

Cycle 50 GMT 28/ 5/2013 11:33:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 340 14.48 115 0 4
2 2005.08 201 13.75 706 0 4
3 1920.04 101 13.59 653 0 0
4 1729.08 101 13.78 576 0 0
5 1455.00 100 13.85 500 0 0
6 1272.16 100 13.97 423 0 0
7 805.56 100 14.17 307 0 0
8 625.60 100 14.29 230 0 0
9 237.00 100 14.42 153 0 0
10 15.04 32 14.74 76 0 100

Cycle 49 GMT 18/ 5/2013 9:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.64 337 14.48 115 0 4
2 1009.32 2 14.48 423 0 0
3 2001.72 201 13.77 696 0 4
4 1914.56 101 13.65 653 0 0
5 1729.80 101 13.78 576 0 0
6 1639.96 100 13.72 576 0 0
7 1237.76 100 13.91 461 0 0
8 956.76 100 14.04 346 0 0
9 590.88 100 14.29 230 0 0
10 216.92 100 14.48 153 0 0
11 4.44 36 14.68 76 0 100

Cycle 48 GMT 8/ 5/2013 7:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 117.72 340 14.61 115 0 4
2 988.92 -3 14.87 76 0 0
3 2004.96 375 13.49 693 0 4
4 1389.44 150 13.65 500 0 0
5 1018.80 150 13.97 384 0 0
6 481.12 150 14.23 230 0 0
7 79.64 119 14.61 76 0 100

Cycle 47 GMT 28/ 4/2013 5:10: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.60 338 14.55 115 0 4
2 1006.84 2 14.68 384 0 0
3 2000.72 375 13.29 691 0 4
4 1390.24 150 13.72 500 0 0
5 1027.48 150 13.91 384 0 0
6 632.72 150 14.17 269 0 0
7 119.20 131 14.61 115 0 100

Cycle 46 GMT 18/ 4/2013 2:59: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 340 14.55 115 0 4
2 997.48 -2 14.80 76 0 0
3 2018.44 375 13.52 697 0 4
4 1419.84 150 13.78 500 0 0
5 1054.48 151 13.91 384 0 0
6 673.40 151 14.10 307 0 0
7 70.52 124 14.68 76 0 100

Cycle 45 GMT 8/ 4/2013 0:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.36 337 14.55 115 0 4
2 1004.68 2 14.61 423 0 0
3 2006.48 375 13.53 699 0 4
4 1364.08 150 13.85 461 0 0
5 1004.00 150 14.04 346 0 0
6 598.60 150 14.23 230 0 0
7 98.16 117 14.68 76 0 100

Cycle 44 GMT 28/ 3/2013 22:27:23

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.60 342 14.48 115 0 4
2 985.84 -5 14.80 76 0 0
3 2001.92 375 13.37 696 0 4
4 1565.08 150 13.72 538 0 0
5 985.84 150 13.91 384 0 0
6 658.00 150 14.23 230 0 0
7 85.00 131 14.61 115 0 100

Cycle 43 GMT 18/ 3/2013 20: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.28 337 14.48 115 0 4
2 1012.48 5 14.61 423 0 0
3 2006.60 375 13.54 696 0 4
4 1345.24 150 13.85 461 0 0
5 981.56 151 13.91 384 0 0
6 594.64 151 14.17 269 0 0
7 115.40 122 14.48 115 0 100

Cycle 42 GMT 8/ 3/2013 17:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.36 334 14.61 115 0 4
2 1006.44 2 14.55 423 0 0
3 2003.00 375 13.56 685 0 4
4 1370.92 150 13.78 461 0 0
5 995.16 150 13.91 384 0 0
6 610.88 150 14.17 269 0 0
7 99.88 121 14.55 76 0 100

Cycle 41 GMT 26/ 2/2013 15:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.04 332 14.36 153 0 4
2 1008.40 2 14.74 423 0 0
3 2005.32 375 13.56 692 0 4
4 1536.64 150 13.78 538 0 0
5 957.96 150 13.97 346 0 0
6 572.44 150 14.17 230 0 0
7 110.44 124 14.48 115 0 100

Cycle 40 GMT 16/ 2/2013 13:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.64 332 14.48 115 0 4
2 2001.88 375 13.58 691 0 4
3 1348.76 150 13.85 500 0 0
4 962.44 150 13.97 384 0 0
5 594.80 150 14.17 269 0 0
6 110.52 119 14.48 115 0 100

Cycle 39 GMT 6/ 2/2013 10:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 117.60 329 14.42 115 0 4
2 1005.20 2 14.74 423 0 0
3 2003.24 375 13.59 689 0 4
4 1365.40 150 13.78 500 0 0
5 983.72 150 13.97 384 0 0
6 463.36 150 14.36 192 0 0
7 142.84 117 14.61 115 0 100

Cycle 38 GMT 27/ 1/2013 8:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.60 334 14.42 115 0 4
2 987.28 -5 15.06 76 0 0
3 2000.48 375 13.58 697 0 4
4 1354.80 150 13.85 500 0 0
5 976.12 150 14.04 346 0 0
6 452.32 150 14.29 192 0 0
7 140.80 119 14.61 115 0 100

Cycle 37 GMT 17/ 1/2013 5:55: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.52 329 14.48 115 0 4
2 1012.44 5 14.87 384 0 0
3 2004.04 375 13.59 694 0 4
4 1364.24 150 13.78 500 0 0
5 980.96 151 13.97 384 0 0
6 589.84 151 14.17 269 0 0
7 100.52 119 14.61 76 0 100

Cycle 36 GMT 7/ 1/2013 3:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.88 325 14.48 115 0 4
2 1009.20 3 14.87 384 0 0
3 2002.28 375 13.59 695 0 4
4 1352.08 150 13.78 500 0 0
5 977.00 150 14.04 384 0 0
6 593.32 150 14.10 230 0 0
7 112.92 119 14.48 115 0 100

Cycle 35 GMT 28/12/2012 1:14:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.28 325 14.36 115 0 4
2 2002.56 375 13.59 692 0 4
3 1350.36 150 13.91 461 0 0
4 963.24 150 14.04 346 0 0
5 448.04 150 14.29 192 0 0
6 83.52 116 14.55 115 0 100

Cycle 34 GMT 17/12/2012 22:39:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 327 14.48 115 0 4
2 991.80 -2 14.93 76 0 0
3 2002.12 375 13.58 701 0 4
4 1334.08 150 13.78 500 0 0
5 954.00 151 14.04 384 0 0
6 559.76 151 14.10 269 0 0
7 106.48 118 14.48 115 0 100

Cycle 33 GMT 7/12/2012 20:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.96 327 14.42 115 0 4
2 2001.96 375 13.60 696 0 4
3 1338.52 150 13.85 461 0 0
4 955.56 151 13.97 384 0 0
5 568.76 151 14.17 230 0 0
6 64.20 119 14.55 76 0 100

Cycle 32 GMT 27/11/2012 17:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.12 325 14.42 115 0 4
2 1006.36 2 14.80 384 0 0
3 2003.24 375 13.59 698 0 4
4 1357.24 150 13.85 461 0 0
5 979.28 150 14.04 346 0 0
6 592.76 150 14.17 269 0 0
7 107.72 122 14.48 115 0 100

Cycle 31 GMT 17/11/2012 15:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.88 327 14.36 115 0 4
2 997.64 -2 14.93 115 0 0
3 2004.88 375 13.60 701 0 4
4 1356.20 150 13.85 500 0 0
5 969.00 150 14.04 346 0 0
6 581.12 150 14.17 230 0 0
7 197.08 124 14.55 115 0 100

Cycle 30 GMT 7/11/2012 13:34:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.56 327 14.36 153 0 4
2 2003.08 375 13.61 700 0 4
3 1363.32 150 13.85 500 0 0
4 970.76 150 13.97 384 0 0
5 576.80 150 14.17 230 0 0
6 108.32 121 14.48 115 0 100

Cycle 29 GMT 28/10/2012 11:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 325 14.42 115 0 4
2 1005.16 2 14.80 423 0 0
3 2003.92 375 13.60 702 0 4
4 1353.24 150 13.85 461 0 0
5 965.24 150 13.97 384 0 0
6 566.00 150 14.10 269 0 0
7 182.84 121 14.48 115 0 100

Cycle 28 GMT 18/10/2012 8:58: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.28 327 14.29 153 0 4
2 994.48 -2 15.12 76 0 0
3 2004.00 375 13.61 701 0 4
4 1336.48 150 13.85 500 0 0
5 956.72 151 13.97 384 0 0
6 574.28 151 14.23 230 0 0
7 112.40 122 14.61 76 0 100

Cycle 27 GMT 8/10/2012 6:37:14

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 325 14.42 115 0 4
2 1006.68 2 14.80 423 0 0
3 2006.28 375 13.62 696 0 4
4 1367.60 150 13.91 461 0 0
5 978.36 150 13.97 346 0 0
6 599.60 150 14.17 230 0 0
7 109.12 121 14.55 115 0 100

Cycle 26 GMT 28/ 9/2012 3:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 117.84 325 14.48 115 0 4
2 2000.40 375 13.64 695 0 4
3 1344.72 150 13.91 461 0 0
4 964.08 150 14.10 307 0 0
5 573.04 150 14.23 230 0 0
6 99.56 116 14.48 115 0 100

Cycle 25 GMT 18/ 9/2012 1:29:40

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.96 327 14.42 115 0 4
2 998.12 -2 15.12 115 0 0
3 2001.24 375 13.64 704 0 4
4 1349.08 150 13.91 500 0 0
5 961.76 150 13.97 384 0 0
6 431.12 150 14.29 230 0 0
7 67.52 119 14.61 76 0 100

Cycle 24 GMT 7/ 9/2012 22:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.16 329 14.48 115 0 4
2 994.00 -2 15.06 115 0 0
3 2002.68 375 13.66 700 0 4
4 1344.04 150 13.85 500 0 0
5 963.76 150 14.04 384 0 0
6 426.88 150 14.23 230 0 0
7 134.12 117 14.61 115 0 100

Cycle 23 GMT 28/ 8/2012 20:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.44 329 14.42 115 0 4
2 2002.36 375 13.67 702 0 4
3 1353.68 150 13.85 500 0 0
4 975.04 150 13.97 384 0 0
5 447.80 150 14.23 230 0 0
6 135.64 117 14.42 153 0 100

Cycle 22 GMT 18/ 8/2012 18: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 330 14.42 115 0 4
2 994.08 -2 15.06 115 0 0
3 2006.72 375 13.67 706 0 4
4 1369.28 150 13.85 500 0 0
5 991.24 151 14.04 346 0 0
6 581.92 151 14.17 269 0 0
7 123.28 122 14.61 115 0 100

Cycle 21 GMT 8/ 8/2012 15:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 117.16 327 14.36 153 0 4
2 1006.16 2 14.87 423 0 0
3 2005.16 375 13.69 707 0 4
4 1354.52 150 13.85 500 0 0
5 971.28 150 13.97 384 0 0
6 583.40 150 14.23 230 0 0
7 113.40 121 14.42 153 0 100

Cycle 20 GMT 29/ 7/2012 15:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.92 324 14.36 115 0 4
2 1007.36 2 15.00 384 0 0
3 2002.84 375 13.70 706 0 4
4 1350.64 150 13.85 461 0 0
5 966.80 150 14.04 346 0 0
6 585.44 150 14.17 269 0 0
7 107.12 126 14.48 115 0 100

Cycle 19 GMT 19/ 7/2012 15:33:28

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.64 327 14.36 153 0 4
2 989.36 -3 15.06 115 0 0
3 2002.68 375 13.71 707 0 4
4 1352.36 150 13.85 500 0 0
5 977.04 150 13.91 384 0 0
6 604.24 150 14.23 269 0 0
7 108.84 122 14.42 153 0 100

Cycle 18 GMT 9/ 7/2012 15:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.60 324 14.48 115 0 4
2 1002.64 2 14.87 423 0 0
3 2001.88 375 13.71 705 0 4
4 1343.68 150 13.85 500 0 0
5 948.00 150 13.97 384 0 0
6 558.56 150 14.17 269 0 0
7 187.40 119 14.48 115 0 100

Cycle 17 GMT 29/ 6/2012 15:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 322 14.42 153 0 4
2 1006.84 2 15.00 384 0 0
3 2005.56 375 13.72 708 0 4
4 1338.52 150 13.85 500 0 0
5 974.80 151 13.97 384 0 0
6 441.52 151 14.23 192 0 0
7 133.16 118 14.48 115 0 100

Cycle 16 GMT 19/ 6/2012 15:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.00 323 14.36 153 0 4
2 993.92 -2 15.12 115 0 0
3 2003.68 375 13.74 704 0 4
4 1205.60 150 13.97 423 0 0
5 1026.04 150 13.97 384 0 0
6 458.00 150 14.23 230 0 0
7 141.08 114 14.55 115 0 100

Cycle 15 GMT 9/ 6/2012 15: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 322 14.48 115 0 4
2 2001.12 375 13.75 701 0 4
3 1352.56 150 13.85 500 0 0
4 822.72 150 14.04 307 0 0
5 481.24 150 14.17 230 0 0
6 152.76 113 14.48 115 0 100

Cycle 14 GMT 30/ 5/2012 14:51:19

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.32 323 14.42 115 0 4
2 997.00 -2 15.19 115 0 0
3 2002.72 375 13.75 703 0 4
4 1363.12 150 13.91 461 0 0
5 969.00 151 13.97 384 0 0
6 585.20 151 14.23 230 0 0
7 28.16 116 14.61 115 0 100

Cycle 13 GMT 20/ 5/2012 14:36:55

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.48 322 14.42 115 0 4
2 2001.80 375 13.75 706 0 4
3 1345.52 150 13.91 461 0 0
4 957.00 150 14.04 346 0 0
5 558.40 150 14.29 230 0 0
6 99.36 114 14.61 115 0 100

Cycle 12 GMT 10/ 5/2012 14: 4: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.28 306 14.36 153 0 4
2 1044.76 15 14.93 423 0 0
3 2000.80 375 13.76 702 0 4
4 1321.52 150 13.91 461 0 0
5 943.88 150 14.04 346 0 0
6 554.80 150 14.17 269 0 0
7 179.72 113 14.48 153 0 100

Cycle 11 GMT 30/ 4/2012 14: 1:22

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 306 14.42 115 0 4
2 1016.36 5 14.93 423 0 0
3 1951.64 375 13.77 691 0 4
4 1325.04 150 13.97 461 0 0
5 952.76 150 14.04 346 0 0
6 436.60 150 14.36 192 0 0
7 72.56 108 14.68 115 0 100

Cycle 10 GMT 20/ 4/2012 12:50:16

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.24 306 14.42 115 0 4
2 1951.32 375 13.78 692 0 4
3 1305.40 151 13.91 461 0 0
4 915.80 150 13.97 346 0 0
5 542.96 150 14.17 269 0 0
6 178.68 115 14.48 153 0 100

Cycle 9 GMT 10/ 4/2012 11:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.52 304 14.29 153 0 4
2 1006.72 2 14.93 423 0 0
3 1951.00 375 13.77 692 0 4
4 1163.24 150 13.91 461 0 0
5 814.12 150 13.97 346 0 0
6 451.44 150 14.23 230 0 0
7 132.32 103 14.61 115 0 100

Cycle 8 GMT 31/ 3/2012 10:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.12 298 14.29 153 0 4
2 1013.56 5 15.00 423 0 0
3 1955.88 375 13.77 689 0 4
4 1167.64 150 13.85 423 0 0
5 806.84 150 13.97 346 0 0
6 424.20 150 14.29 192 0 0
7 129.24 106 14.42 153 0 100

Cycle 7 GMT 21/ 3/2012 9:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.32 296 14.29 153 0 4
2 1017.56 5 15.06 423 0 0
3 1902.88 900 13.39 657 0 4
4 153.92 80 14.55 153 0 0
5 85.44 34 14.61 115 0 100

Cycle 6 GMT 11/ 3/2012 9:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.04 298 14.29 115 0 4
2 989.24 -3 15.25 115 0 0
3 1901.60 900 13.39 652 0 4
4 257.84 80 14.42 192 0 0
5 68.40 32 14.74 115 0 100

Cycle 5 GMT 1/ 3/2012 11: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.56 293 14.23 153 0 4
2 1014.92 5 15.00 423 0 0
3 1900.64 900 13.38 655 0 4
4 269.60 80 14.48 153 0 0
5 123.92 32 14.61 153 0 100

Cycle 4 GMT 20/ 2/2012 12: 9:27

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.96 299 14.23 153 0 4
2 1516.88 900 13.54 537 0 4
3 121.52 80 14.48 153 0 0
4 62.96 1 14.61 153 0 100

Cycle 3 GMT 19/ 2/2012 13:51: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.60 301 14.29 115 0 4
2 998.16 -2 15.25 115 0 0
3 1510.24 900 13.54 537 0 4
4 125.08 80 14.55 115 0 0
5 68.72 1 14.61 153 0 100

Cycle 2 GMT 18/ 2/2012 16: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.84 293 14.23 115 0 4
2 1021.16 7 15.00 423 0 0
3 1508.64 900 13.53 536 0 4
4 116.48 80 14.48 115 0 0
5 57.64 5 14.55 153 0 100

Cycle 1 GMT 17/ 2/2012 18: 6:28

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 293 14.29 153 0 4
2 1004.08 2 15.00 423 0 0
3 993.92 606 13.89 378 0 100

Cycle 0 GMT 17/ 2/2012 5:59: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.36 839 14.49 142 0 104