SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8115 WMO= 5904075


Cycle 223 GMT 22/ 1/2018 12:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 49 10.54 403 6 6
2 1209.68 101 7.02 1780 6 6
3 1175.00 40 7.27 1738 6 6
4 1100.20 40 7.51 1634 6 6
5 1016.48 40 7.66 1542 6 6
6 184.04 40 10.14 499 6 8
7 0.20 41 10.75 267 6 10
8 0.16 200 10.71 275 6 32

Cycle 222 GMT 12/ 1/2018 17:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.28 49 10.54 423 6 6
2 1206.68 101 7.22 1775 6 6
3 1171.64 40 7.45 1728 6 6
4 1100.40 40 7.65 1649 6 6
5 715.44 40 8.65 1171 6 7
6 46.56 40 10.58 336 6 8
7 -0.04 40 10.73 291 6 9
8 -0.12 201 10.74 279 6 32

Cycle 221 GMT 2/ 1/2018 22:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.12 49 10.54 423 6 6
2 1208.64 101 7.36 1780 6 6
3 1165.68 40 7.64 1720 6 6
4 1082.64 40 7.85 1631 6 6
5 507.52 40 9.28 917 6 7
6 41.84 40 10.64 316 6 9
7 0.16 201 10.77 277 6 34

Cycle 220 GMT 24/12/2017 3:51: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.24 48 10.66 403 6 6
2 1220.44 101 7.43 1799 6 6
3 1177.24 40 7.66 1750 6 6
4 1094.36 40 7.86 1647 6 6
5 602.08 40 9.12 1045 6 7
6 34.08 40 10.71 308 6 9
7 0.04 201 10.79 277 6 33

Cycle 219 GMT 14/12/2017 8:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.92 48 10.54 442 6 6
2 1903.92 101 4.88 3316 6 7
3 1953.64 40 5.19 3205 6 7
4 1986.88 40 4.93 3380 6 6
5 2013.24 40 4.85 3419 6 6
6 2036.64 40 5.05 3312 6 6
7 2052.20 40 4.86 3410 6 6
8 2058.60 40 4.86 3410 6 6
9 2053.96 40 5.02 3326 6 6
10 2046.08 40 4.86 3399 6 6
11 2040.88 40 4.95 3350 6 6
12 2034.40 40 4.85 3390 6 6
13 2023.72 40 4.89 3340 6 7
14 2008.92 40 4.89 3330 6 7
15 1996.04 40 4.95 3289 6 6
16 1981.68 40 4.89 3321 6 7
17 1965.36 40 4.96 3279 6 7
18 1943.60 40 4.92 3268 6 7

Cycle 218 GMT 12/12/2017 5:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 49 10.66 403 6 6
2 1205.96 100 7.63 1788 6 6
3 1171.08 40 7.87 1748 6 6
4 1081.88 40 8.06 1636 6 6
5 573.00 40 9.36 997 6 7
6 21.80 40 10.75 297 6 10
7 -0.00 40 10.84 272 6 16
8 -0.04 201 10.79 283 6 30

Cycle 217 GMT 2/12/2017 10:51:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.92 48 10.66 423 6 6
2 1211.12 101 7.73 1797 6 6
3 1166.24 40 7.97 1746 6 6
4 986.68 40 8.39 1524 6 6
5 383.72 40 9.82 774 6 8
6 0.24 40 10.87 272 6 10
7 0.16 201 10.83 275 6 31

Cycle 216 GMT 22/11/2017 15:59: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.88 48 10.60 423 6 6
2 1211.84 101 7.78 1801 6 6
3 1159.36 40 8.05 1734 6 6
4 1072.32 40 8.23 1639 6 6
5 449.00 40 9.69 855 6 8
6 0.76 201 10.83 282 6 35

Cycle 215 GMT 12/11/2017 21:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 48 10.66 423 6 6
2 1201.04 101 7.87 1802 6 6
3 1145.00 40 8.13 1717 6 6
4 874.72 40 8.79 1378 6 6
5 458.48 40 9.73 863 6 8
6 0.08 40 10.90 271 6 10
7 -0.12 201 10.84 279 6 24

Cycle 214 GMT 3/11/2017 2:22: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 47 10.66 423 6 6
2 1903.00 101 6.38 2794 6 6
3 1844.56 40 6.90 2578 6 6
4 1769.60 40 6.88 2536 6 6
5 1679.80 40 7.19 2416 6 6
6 1188.92 40 8.15 1784 6 6
7 500.60 40 9.69 924 6 8
8 0.24 40 10.87 296 6 9
9 0.20 201 10.85 288 6 31

Cycle 213 GMT 1/11/2017 3:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.92 48 10.66 423 6 6
2 1201.84 101 8.02 1785 6 6
3 1142.56 40 8.32 1701 6 6
4 961.52 40 8.72 1480 6 6
5 153.88 40 10.48 474 6 8
6 0.16 40 10.90 273 6 8
7 0.20 201 10.86 278 6 31

Cycle 212 GMT 22/10/2017 8:37: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 48 10.66 423 6 6
2 1221.12 100 8.02 1817 6 6
3 1171.00 40 8.29 1755 6 6
4 987.08 40 8.68 1520 6 7
5 187.84 40 10.43 509 6 8
6 -0.00 40 10.90 278 6 11
7 -0.04 201 10.88 269 6 30

Cycle 211 GMT 12/10/2017 13:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.12 48 10.66 442 6 6
2 1198.52 101 8.14 1788 6 6
3 1149.24 40 8.41 1717 6 6
4 966.96 40 8.79 1503 6 6
5 159.60 40 10.50 479 6 8
6 0.12 201 10.88 281 6 25

Cycle 210 GMT 2/10/2017 18:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.88 48 10.73 423 6 6
2 1208.08 100 8.22 1793 6 6
3 1145.96 40 8.47 1710 6 6
4 963.24 40 8.84 1491 6 7
5 76.72 40 10.74 368 6 8
6 -0.00 40 10.95 271 6 17
7 0.04 201 10.87 287 6 28

Cycle 209 GMT 22/ 9/2017 23:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.28 48 10.73 403 6 6
2 980.24 -1 10.73 403 6 6
3 1911.40 101 6.82 2690 6 6
4 1834.24 40 7.24 2553 6 6
5 1559.84 40 7.71 2239 6 6
6 1281.56 40 8.18 1927 6 6
7 582.44 40 9.62 1045 6 7
8 0.16 201 10.90 281 6 28

Cycle 208 GMT 21/ 9/2017 1: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.28 47 10.66 423 6 6
2 1216.16 101 8.20 1809 6 6
3 1152.00 40 8.51 1706 6 6
4 871.32 40 9.04 1384 6 7
5 139.20 40 10.59 451 6 8
6 -0.12 40 10.92 276 6 9
7 -0.12 201 10.88 279 6 32

Cycle 207 GMT 11/ 9/2017 6:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.88 48 10.73 423 6 6
2 978.72 -1 10.73 423 6 6
3 1215.52 100 8.24 1811 6 6
4 1154.48 40 8.56 1698 6 6
5 782.72 40 9.28 1278 6 7
6 83.84 40 10.72 379 6 8
7 -0.12 40 10.95 270 6 8
8 -0.08 201 10.88 285 6 28

Cycle 206 GMT 1/ 9/2017 11:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.64 44 10.79 403 6 6
2 1072.52 2 8.94 1634 6 6
3 1029.00 1 9.00 1576 6 6
4 1216.76 101 8.29 1809 6 6
5 1165.04 40 8.51 1772 6 6
6 799.72 40 9.25 1295 6 7
7 83.12 40 10.72 381 6 8
8 0.32 40 10.94 272 6 16
9 0.20 201 10.89 281 6 26

Cycle 205 GMT 22/ 8/2017 16:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.68 36 10.73 423 6 6
2 1141.68 5 9.00 1711 6 6
3 1182.64 7 8.75 1807 6 6
4 1273.76 101 8.23 1878 6 6
5 1207.48 40 8.49 1781 6 6
6 826.40 40 9.24 1324 6 7
7 120.28 40 10.66 426 6 9
8 -0.00 40 10.97 267 6 10
9 -0.04 201 10.88 287 6 32

Cycle 204 GMT 12/ 8/2017 23:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 36 10.79 423 6 6
2 1261.16 10 8.62 1865 6 6
3 1111.00 4 9.20 1673 6 6
4 1902.64 101 6.27 2722 6 7
5 1848.32 41 6.93 2598 6 6
6 1767.76 41 7.28 2493 6 6
7 1487.36 41 7.81 2190 6 6
8 1011.92 41 8.84 1589 6 6
9 396.12 41 10.11 793 6 8
10 -0.00 40 10.94 285 6 11
11 -0.00 201 10.91 279 6 29

Cycle 203 GMT 11/ 8/2017 1:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 40 11.69 442 6 6
2 1084.48 3 10.98 1653 6 6
3 1210.80 101 6.20 1781 6 6
4 1231.20 41 7.35 1832 6 6
5 1172.64 41 7.82 1743 6 6
6 988.68 41 8.56 1521 6 6
7 279.24 41 10.37 631 6 8
8 0.24 201 11.00 274 6 25

Cycle 202 GMT 1/ 8/2017 6:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 37 12.57 461 6 6
2 1057.48 2 12.00 1673 6 6
3 1205.80 101 6.73 1807 6 6
4 1187.64 41 8.32 1760 6 6
5 1117.44 41 8.64 1684 6 6
6 632.32 41 10.16 1078 6 8
7 0.68 201 11.66 287 6 27

Cycle 201 GMT 22/ 7/2017 11:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.32 36 13.53 442 6 6
2 1206.40 100 4.42 1823 6 7
3 1327.36 41 7.54 1957 6 6
4 1381.88 41 7.86 1997 6 6
5 1345.08 41 8.60 1970 6 6
6 1263.92 41 9.13 1884 6 6
7 581.04 41 11.03 1036 6 8
8 0.12 40 12.80 298 6 13
9 0.16 201 12.25 301 6 37

Cycle 200 GMT 12/ 7/2017 15:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.04 36 13.91 480 6 6
2 1207.76 101 6.04 1838 6 6
3 1256.08 41 8.78 1857 6 6
4 1194.68 41 9.19 1791 6 6
5 823.52 41 10.67 1343 6 8
6 19.00 41 13.66 324 6 13
7 -0.08 41 13.71 303 6 19
8 -0.08 200 12.99 308 6 41

Cycle 199 GMT 2/ 7/2017 20: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.04 36 13.91 442 6 6
2 1901.36 101 8.11 2673 6 6
3 1811.48 41 9.62 2556 6 6
4 1017.68 41 11.80 1611 6 8
5 92.40 41 13.90 447 6 13
6 0.28 40 14.26 322 6 26
7 0.04 201 13.43 311 6 43

Cycle 198 GMT 30/ 6/2017 21:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 36 13.91 480 6 6
2 1190.24 101 5.66 1838 6 6
3 1266.36 41 9.41 1874 6 6
4 1219.44 41 9.47 1834 6 6
5 840.72 41 11.68 1360 6 8
6 -0.00 40 14.17 307 6 13
7 -0.04 201 13.50 305 6 40

Cycle 197 GMT 21/ 6/2017 2:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.36 36 14.04 442 6 6
2 1198.44 100 5.57 1859 6 6
3 1282.48 41 9.59 1904 6 6
4 1247.28 41 9.74 1852 6 6
5 1160.88 41 10.16 1756 6 8
6 101.52 41 13.92 434 6 13
7 0.32 40 14.23 310 6 23
8 0.24 201 13.57 309 6 41

Cycle 196 GMT 11/ 6/2017 7: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.84 36 14.04 442 6 6
2 1195.64 101 5.72 1886 6 6
3 1254.24 41 9.48 1872 6 6
4 1194.32 41 9.92 1777 6 6
5 915.08 41 11.65 1466 6 8
6 50.00 41 14.05 368 6 14
7 -0.04 40 14.26 305 6 22
8 -0.04 201 13.64 310 6 45

Cycle 195 GMT 1/ 6/2017 11:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 37 14.10 442 6 6
2 971.44 -1 14.10 442 6 6
3 1209.48 101 7.03 1839 6 6
4 1192.72 41 10.23 1806 6 6
5 925.56 41 11.80 1479 6 8
6 38.80 41 14.11 356 6 14
7 -0.08 200 13.90 315 6 44

Cycle 194 GMT 22/ 5/2017 16:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.32 36 14.04 442 6 6
2 1902.84 101 8.14 2686 6 6
3 1819.04 41 10.12 2606 6 6
4 1199.24 41 12.05 1829 6 9
5 47.96 41 14.12 381 6 14
6 0.04 40 14.26 320 6 20
7 -0.04 201 13.84 309 6 48

Cycle 193 GMT 20/ 5/2017 18:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 36 14.10 442 6 6
2 1196.92 100 5.89 1829 6 6
3 1262.36 41 10.26 1891 6 6
4 1190.84 41 10.66 1826 6 7
5 685.40 41 12.60 1180 6 10
6 -0.12 201 13.95 312 6 47

Cycle 192 GMT 10/ 5/2017 23:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 35 13.97 461 6 6
2 1214.88 101 5.85 1927 6 6
3 1277.88 41 10.28 1910 6 6
4 1207.64 41 10.71 1835 6 7
5 706.76 41 12.57 1200 6 9
6 0.24 40 14.20 316 6 19
7 0.16 201 13.85 312 6 37

Cycle 191 GMT 1/ 5/2017 4:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.32 37 13.97 461 6 6
2 981.56 -1 13.97 461 6 6
3 1224.76 101 6.49 1896 6 6
4 1253.12 41 10.42 1891 6 6
5 1176.24 41 10.82 1790 6 7
6 252.00 41 13.64 630 6 12
7 -0.08 201 13.98 310 6 38

Cycle 190 GMT 21/ 4/2017 9:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.64 37 14.04 461 6 6
2 1189.52 101 7.53 1779 6 6
3 1147.60 41 10.93 1742 6 6
4 776.60 41 12.32 1273 6 9
5 39.08 41 14.09 354 6 16
6 -0.04 40 14.19 323 6 23
7 -0.24 201 13.90 310 6 50

Cycle 189 GMT 11/ 4/2017 14:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.16 37 13.97 442 6 6
2 978.20 -1 13.97 442 6 6
3 1901.36 101 8.17 2677 6 6
4 1631.00 41 11.31 2377 6 6
5 991.56 41 12.47 1576 6 10
6 18.88 41 14.16 347 6 14
7 0.56 201 14.05 315 6 41

Cycle 188 GMT 9/ 4/2017 16:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.68 37 13.97 442 6 6
2 1189.96 101 6.30 1872 6 6
3 1246.00 41 10.82 1868 6 6
4 1170.64 41 11.11 1770 6 7
5 365.12 41 13.46 773 6 11
6 15.20 41 14.11 337 6 16
7 -0.00 201 14.03 310 6 44

Cycle 187 GMT 30/ 3/2017 21:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 37 14.10 442 6 6
2 1193.12 101 6.74 1831 6 6
3 1222.72 41 10.94 1821 6 6
4 1138.12 41 11.27 1720 6 7
5 254.64 41 13.68 624 6 13
6 0.24 40 14.15 316 6 18
7 0.16 201 13.99 304 6 42

Cycle 186 GMT 21/ 3/2017 2:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.72 37 13.97 461 6 6
2 1195.04 101 7.03 1840 6 6
3 1190.56 41 10.89 1791 6 6
4 1016.88 41 11.64 1580 6 8
5 75.28 41 13.99 408 6 15
6 -0.16 40 14.13 315 6 18
7 -0.12 201 14.02 306 6 52

Cycle 185 GMT 11/ 3/2017 7:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.64 37 14.10 442 6 6
2 1198.88 101 7.82 1819 6 6
3 1142.88 41 11.19 1742 6 6
4 667.76 41 12.77 1137 6 11
5 31.76 41 14.02 367 6 15
6 0.08 40 14.13 323 6 23
7 0.08 201 13.97 315 6 48

Cycle 184 GMT 1/ 3/2017 13:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.40 37 14.04 442 6 6
2 1910.20 101 8.25 2684 6 6
3 1819.84 41 10.84 2598 6 6
4 984.48 41 12.48 1575 6 10
5 40.96 41 14.07 375 6 14
6 0.08 201 14.10 315 6 38

Cycle 183 GMT 27/ 2/2017 15: 7: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.28 37 14.04 461 6 6
2 1211.84 100 6.14 1877 6 6
3 1262.24 40 10.98 1881 6 6
4 1190.72 40 11.27 1819 6 6
5 481.76 41 13.28 916 6 11
6 -0.00 201 14.10 306 6 38

Cycle 182 GMT 17/ 2/2017 20:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.40 37 14.10 442 6 6
2 1207.92 101 6.45 1889 6 6
3 1254.16 41 11.04 1878 6 6
4 1174.68 41 11.36 1791 6 7
5 433.52 41 13.36 868 6 11
6 -0.00 40 14.17 316 6 21
7 -0.00 201 14.04 308 6 35

Cycle 181 GMT 8/ 2/2017 1:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.36 37 14.04 442 6 6
2 1198.60 101 6.74 1890 6 6
3 1236.68 41 10.95 1833 6 6
4 1152.08 41 11.25 1753 6 7
5 295.00 41 13.59 688 6 13
6 -0.00 40 14.16 314 6 16
7 -0.00 201 14.03 310 6 48

Cycle 180 GMT 29/ 1/2017 6:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.72 37 14.04 442 6 6
2 1213.40 101 7.58 1812 6 6
3 1172.88 40 11.23 1770 6 7
4 701.88 40 12.72 1197 6 9
5 25.24 40 14.04 349 6 15
6 0.12 40 14.13 317 6 21
7 -0.04 201 14.03 309 6 47

Cycle 179 GMT 19/ 1/2017 11:30: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 37 13.97 461 6 6
2 1903.08 101 8.24 2683 6 6
3 1625.88 41 11.48 2345 6 7
4 911.16 41 12.61 1474 6 10
5 24.32 41 14.12 344 6 14
6 -0.00 40 14.16 321 6 22
7 -0.04 201 14.06 308 7 52

Cycle 178 GMT 17/ 1/2017 13:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.44 37 14.10 423 6 6
2 1204.00 100 6.15 1863 6 6
3 1268.84 40 11.16 1879 6 6
4 1196.64 40 11.44 1803 6 7
5 384.92 41 13.45 805 6 11
6 0.40 201 14.11 308 6 39

Cycle 177 GMT 7/ 1/2017 18: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.16 36 13.97 461 6 6
2 1209.00 101 6.44 1878 6 6
3 1259.16 41 11.19 1881 6 6
4 1187.52 41 11.55 1783 6 7
5 331.20 41 13.55 735 6 12
6 0.08 40 14.14 314 6 16
7 -0.00 201 14.04 307 6 43

Cycle 176 GMT 28/12/2016 23: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.36 36 13.97 442 6 6
2 1210.36 101 6.76 1857 6 6
3 1239.64 41 10.99 1856 6 6
4 1156.12 41 11.38 1765 6 8
5 99.00 41 13.92 446 6 12
6 0.04 40 14.13 309 6 16
7 -0.04 201 14.06 304 6 41

Cycle 175 GMT 19/12/2016 4: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 36 14.10 442 6 6
2 1218.00 101 7.59 1830 6 6
3 1181.24 41 11.24 1801 6 6
4 892.36 41 12.31 1438 6 10
5 0.08 40 14.14 308 6 13
6 0.04 201 14.07 301 6 44

Cycle 174 GMT 9/12/2016 9:22: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.84 37 14.04 442 6 6
2 1912.08 101 8.00 2697 6 6
3 1821.88 41 11.06 2600 6 6
4 1103.52 41 12.29 1723 6 9
5 105.24 41 13.94 456 6 14
6 0.08 40 14.14 321 6 19
7 -0.00 201 14.05 309 6 43

Cycle 173 GMT 7/12/2016 11: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.92 36 13.91 461 6 6
2 1212.52 100 5.96 1871 6 6
3 1293.36 41 11.07 1923 6 6
4 1223.52 41 11.40 1856 6 7
5 533.52 41 13.19 978 6 10
6 0.24 40 14.11 321 6 17
7 0.20 201 14.02 308 6 44

Cycle 172 GMT 27/11/2016 15:51: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.32 36 13.91 442 6 6
2 1206.24 100 6.19 1841 6 6
3 1258.88 40 11.16 1853 6 6
4 1181.64 41 11.52 1795 6 7
5 251.52 41 13.64 639 6 12
6 0.24 41 14.07 326 6 17
7 0.04 200 13.97 316 6 45

Cycle 171 GMT 17/11/2016 20:46: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 36 13.97 442 6 6
2 1207.32 101 6.53 1819 6 6
3 1245.68 40 11.02 1864 6 6
4 1163.52 40 11.42 1785 6 7
5 128.24 40 13.82 493 6 12
6 -0.04 201 14.04 311 6 46

Cycle 170 GMT 8/11/2016 1:43:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 36 13.97 442 6 6
2 1211.52 101 7.43 1803 6 6
3 1176.40 40 11.35 1797 6 7
4 805.88 40 12.49 1356 6 10
5 0.16 40 14.08 323 6 15
6 0.12 201 13.99 318 6 44

Cycle 169 GMT 29/10/2016 6:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.20 36 13.78 480 6 6
2 1902.00 101 7.96 2691 6 6
3 1813.68 41 11.08 2598 6 6
4 1073.36 41 12.37 1660 6 10
5 38.76 41 14.03 370 6 14
6 -0.00 40 14.14 321 6 20
7 -0.04 201 14.05 308 6 49

Cycle 168 GMT 27/10/2016 8:46: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 36 13.91 461 6 6
2 1202.44 100 5.86 1843 6 6
3 1289.80 41 11.19 1909 6 6
4 1226.96 41 11.53 1866 6 7
5 724.16 41 12.83 1235 6 11
6 0.24 201 14.03 318 6 40

Cycle 167 GMT 17/10/2016 13:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.84 36 13.97 461 6 6
2 1205.16 100 6.01 1838 6 6
3 1282.28 41 11.05 1908 6 6
4 1227.44 41 11.49 1858 6 7
5 518.08 41 13.18 971 6 11
6 0.20 40 14.08 331 6 14
7 0.12 201 13.95 322 6 44

Cycle 166 GMT 7/10/2016 18:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.88 36 13.91 461 6 6
2 1202.52 100 6.52 1775 6 6
3 1238.32 40 11.11 1863 6 6
4 1153.16 40 11.59 1765 6 8
5 193.72 41 13.69 573 6 12
6 0.08 201 14.01 313 6 45

Cycle 165 GMT 27/ 9/2016 23:34: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.28 36 13.97 442 6 6
2 1217.36 101 7.58 1873 6 6
3 1189.28 41 11.42 1802 6 7
4 909.12 41 12.34 1474 6 9
5 0.24 201 14.01 315 6 40

Cycle 164 GMT 18/ 9/2016 4:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.72 36 13.85 461 6 6
2 1905.04 101 7.89 2702 6 6
3 1732.04 41 11.30 2501 6 6
4 1104.76 41 12.29 1713 6 9
5 103.84 41 13.89 457 6 15
6 0.08 40 14.15 314 6 25
7 0.04 201 14.04 308 6 48

Cycle 163 GMT 16/ 9/2016 6:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.52 36 13.78 500 6 6
2 1214.04 100 5.45 1876 6 6
3 1306.20 41 11.17 1953 6 6
4 1254.84 41 11.59 1892 6 7
5 765.64 41 12.79 1277 6 10
6 0.28 41 14.12 318 6 14
7 0.24 200 13.97 316 6 43

Cycle 162 GMT 6/ 9/2016 11:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.84 37 13.91 442 6 6
2 982.64 -1 13.91 442 6 6
3 1218.32 100 5.63 1883 6 6
4 1293.80 41 11.24 1929 6 6
5 1241.84 41 11.66 1858 6 7
6 755.48 41 12.76 1292 6 11
7 0.24 40 14.08 326 6 16
8 0.16 201 13.96 322 6 46

Cycle 161 GMT 27/ 8/2016 16: 7: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 36 13.78 480 6 6
2 1206.80 101 6.18 1877 6 6
3 1261.88 41 11.24 1892 6 6
4 1192.88 41 11.68 1823 6 8
5 470.88 41 13.24 915 6 12
6 -0.04 200 14.00 311 6 41

Cycle 160 GMT 17/ 8/2016 21:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.16 36 13.85 461 6 6
2 1212.28 101 7.58 1857 6 6
3 1185.40 41 11.49 1808 6 7
4 898.48 41 12.39 1452 6 10
5 0.36 201 14.01 316 6 35

Cycle 159 GMT 8/ 8/2016 2:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.56 36 13.85 480 6 6
2 1910.92 101 7.73 2722 6 6
3 1733.96 41 11.28 2514 6 6
4 1023.72 41 12.42 1616 6 9
5 32.84 41 14.02 367 6 14
6 0.04 40 14.17 323 6 22
7 -0.04 201 14.06 312 6 46

Cycle 158 GMT 6/ 8/2016 4: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.28 35 13.91 461 6 6
2 1214.76 100 5.52 1878 6 6
3 1299.60 41 11.27 1928 6 6
4 1247.36 41 11.65 1903 6 7
5 658.56 41 12.94 1157 6 11
6 -0.00 40 14.10 321 6 18
7 -0.08 201 13.99 315 6 49

Cycle 157 GMT 27/ 7/2016 8:48: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 37 13.85 461 6 6
2 980.64 -1 13.85 461 6 6
3 1224.20 100 5.33 1899 6 6
4 1320.64 41 11.18 1959 6 6
5 1275.24 41 11.57 1938 6 6
6 885.80 41 12.54 1440 6 9
7 0.36 40 14.05 331 6 17
8 0.96 201 13.97 321 6 53

Cycle 156 GMT 17/ 7/2016 13:30: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.04 37 13.85 461 6 6
2 1200.04 101 6.05 1833 6 6
3 1261.28 41 11.14 1902 6 6
4 1191.12 41 11.63 1833 6 7
5 366.72 41 13.39 779 6 11
6 -0.24 40 14.06 332 6 19
7 -0.24 201 13.97 314 6 47

Cycle 155 GMT 7/ 7/2016 18:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.72 37 14.04 423 6 6
2 981.36 -1 14.04 423 6 6
3 1194.96 101 7.41 1817 6 6
4 1171.80 41 11.55 1785 6 7
5 901.80 41 12.41 1470 6 9
6 -0.00 200 14.00 318 6 34

Cycle 154 GMT 27/ 6/2016 23:33:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.44 37 13.91 461 6 6
2 975.72 -1 13.91 461 6 6
3 1901.08 101 7.92 2714 6 6
4 1717.88 41 11.37 2476 6 6
5 1072.72 41 12.39 1673 6 9
6 0.04 40 14.14 315 6 14
7 -0.04 201 14.10 308 6 47

Cycle 153 GMT 26/ 6/2016 1:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 37 13.91 461 6 6
2 1202.84 100 4.95 1912 6 6
3 1294.48 41 11.19 1930 6 6
4 1257.60 41 11.68 1900 6 7
5 901.32 41 12.60 1458 6 9
6 0.20 40 14.08 317 6 13
7 0.16 201 14.07 307 6 47

Cycle 152 GMT 16/ 6/2016 6: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.76 37 13.78 480 6 6
2 1194.36 100 4.87 1865 6 6
3 1302.64 41 11.16 1928 6 6
4 1273.40 41 11.59 1928 6 6
5 998.04 41 12.42 1576 6 8
6 0.16 40 14.08 327 6 12
7 0.16 201 14.05 318 6 42

Cycle 151 GMT 6/ 6/2016 10:43: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.36 37 13.91 461 6 6
2 1199.16 100 5.45 1863 6 6
3 1289.72 41 11.19 1933 6 6
4 1241.72 41 11.64 1892 6 7
5 758.36 41 12.80 1290 6 9
6 0.48 201 14.03 325 6 41

Cycle 150 GMT 27/ 5/2016 15:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.68 37 13.91 461 6 6
2 1209.56 101 6.90 1867 6 6
3 1233.84 41 11.43 1872 6 6
4 970.52 41 12.39 1538 6 8
5 55.60 41 13.94 398 6 13
6 0.24 40 14.10 327 6 19
7 0.12 201 14.05 318 6 43

Cycle 149 GMT 17/ 5/2016 20:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.40 37 13.97 461 6 6
2 1901.08 101 8.06 2701 6 6
3 1812.00 41 11.30 2570 6 6
4 1167.00 41 12.31 1774 6 8
5 63.76 41 13.98 406 6 13
6 -0.12 201 14.11 319 6 40

Cycle 148 GMT 15/ 5/2016 22:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.00 37 13.91 461 6 6
2 1202.32 100 4.81 1894 6 6
3 1318.52 41 11.19 1946 6 6
4 1294.24 41 11.69 1943 6 6
5 1106.00 41 12.29 1730 6 8
6 49.36 41 13.98 381 6 13
7 0.12 40 14.16 327 6 19
8 -0.04 201 14.10 311 6 41

Cycle 147 GMT 6/ 5/2016 3: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.32 37 13.91 461 6 6
2 1201.96 100 5.22 1845 6 6
3 1304.72 41 11.27 1941 6 6
4 1259.96 41 11.76 1909 6 6
5 868.76 41 12.75 1402 6 10
6 0.32 40 14.11 318 6 14
7 0.16 201 14.09 317 6 36

Cycle 146 GMT 26/ 4/2016 7:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.12 37 13.97 442 6 6
2 1200.44 100 5.49 1869 6 6
3 1289.20 41 11.30 1921 6 6
4 1244.04 41 11.71 1900 6 7
5 854.68 41 12.70 1416 6 10
6 44.24 41 14.00 382 6 16
7 -0.08 41 14.17 329 6 19
8 -0.08 200 14.07 324 7 55

Cycle 145 GMT 16/ 4/2016 12:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 36 13.91 461 6 6
2 1206.36 101 7.02 1873 6 6
3 1221.68 40 11.50 1858 6 6
4 1132.84 40 11.94 1768 6 8
5 31.52 40 14.00 357 6 13
6 0.24 41 14.17 318 6 9
7 0.16 200 14.09 310 6 43

Cycle 144 GMT 6/ 4/2016 17:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.28 37 13.91 461 6 6
2 1907.44 101 8.13 2687 6 6
3 1730.88 41 11.42 2529 6 7
4 1082.84 41 12.43 1699 6 9
5 6.32 41 14.13 315 6 14
6 0.08 41 14.22 314 6 23
7 -0.00 200 14.16 312 6 50

Cycle 143 GMT 4/ 4/2016 19:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 37 13.97 461 6 6
2 1203.44 100 5.40 1886 6 6
3 1289.88 41 11.20 1944 6 6
4 1249.28 41 11.81 1915 6 7
5 860.92 41 12.80 1415 6 10
6 0.04 40 14.13 318 6 16
7 -0.04 201 14.12 314 6 41

Cycle 142 GMT 26/ 3/2016 0:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.56 37 13.91 461 6 6
2 1207.56 100 4.67 1887 6 6
3 1313.04 41 11.31 1962 6 6
4 1296.88 41 11.81 1974 6 6
5 1012.76 41 12.63 1602 6 9
6 55.72 41 13.99 400 6 13
7 0.16 201 14.14 324 6 42

Cycle 141 GMT 16/ 3/2016 5:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 37 13.97 461 6 6
2 1204.80 100 5.78 1826 6 6
3 1295.36 41 11.37 1931 6 6
4 1229.20 41 11.87 1886 6 7
5 612.52 41 13.11 1101 6 10
6 0.44 201 14.12 311 6 37

Cycle 140 GMT 6/ 3/2016 10: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.16 36 14.10 442 6 6
2 1207.40 101 7.31 1837 6 6
3 1189.16 40 11.69 1826 6 6
4 816.88 40 12.75 1348 6 10
5 13.72 40 14.07 339 6 13
6 0.12 201 14.12 318 6 41

Cycle 139 GMT 25/ 2/2016 15:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.48 36 13.97 442 6 6
2 1909.12 101 8.55 2716 6 6
3 1723.36 41 11.60 2487 6 7
4 871.04 41 12.82 1411 6 11
5 30.92 41 14.09 359 6 15
6 0.16 40 14.23 318 6 25
7 -0.00 201 14.16 311 6 48

Cycle 138 GMT 23/ 2/2016 17:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.96 37 14.10 442 6 6
2 1205.88 101 5.93 1836 6 6
3 1260.96 41 11.55 1903 6 6
4 1193.04 41 12.14 1812 6 7
5 193.20 41 13.75 567 6 12
6 0.08 40 14.17 312 6 17
7 -0.04 201 14.14 304 6 38

Cycle 137 GMT 13/ 2/2016 21:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 36 13.97 442 6 6
2 1211.60 101 6.03 1845 6 6
3 1269.76 41 11.66 1903 6 6
4 1192.80 41 12.26 1803 6 7
5 254.28 41 13.67 653 6 12
6 0.20 201 14.12 312 6 41

Cycle 136 GMT 4/ 2/2016 2:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.92 36 13.97 423 6 6
2 1214.96 100 6.61 1809 6 6
3 1254.96 40 11.72 1891 6 6
4 1173.52 40 12.23 1775 6 8
5 186.72 41 13.76 555 6 13
6 0.04 201 14.13 306 6 44

Cycle 135 GMT 25/ 1/2016 7:57: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.68 36 14.04 442 6 6
2 1205.80 101 8.10 1818 6 6
3 1166.84 40 12.03 1768 6 7
4 670.04 40 13.09 1149 6 10
5 0.28 40 14.18 312 6 16
6 0.04 201 14.10 302 6 43

Cycle 134 GMT 15/ 1/2016 13:14: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.32 37 13.97 442 6 6
2 982.12 -1 13.97 442 6 6
3 1908.56 101 9.04 2710 6 6
4 1524.12 41 11.97 2241 6 7
5 575.96 41 13.27 1042 6 12
6 0.12 40 14.18 322 6 17
7 0.08 201 14.11 310 6 46

Cycle 133 GMT 13/ 1/2016 15: 5: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.64 36 13.91 480 6 6
2 1212.16 100 6.70 1845 6 6
3 1246.12 40 11.79 1904 6 7
4 1157.08 40 12.34 1779 6 8
5 79.88 41 13.96 437 6 14
6 0.08 40 14.22 326 6 21
7 -0.00 201 14.10 314 6 45

Cycle 132 GMT 3/ 1/2016 20: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.00 36 14.10 423 6 6
2 1212.52 100 7.18 1868 6 6
3 1224.28 41 11.85 1882 6 7
4 958.92 41 12.72 1522 6 9
5 34.60 41 14.06 375 6 14
6 0.12 40 14.21 329 6 15
7 -0.00 201 14.11 317 6 47

Cycle 131 GMT 25/12/2015 1:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.56 36 13.97 461 6 6
2 980.80 -1 13.97 461 6 6
3 1025.12 1 11.75 1576 6 6
4 1211.40 100 7.35 1844 6 6
5 1211.12 41 11.88 1872 6 6
6 933.92 41 12.75 1500 6 9
7 30.84 41 14.07 366 6 14
8 0.08 41 14.20 331 6 20
9 0.08 200 14.12 311 6 46

Cycle 130 GMT 15/12/2015 6:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.64 36 14.04 442 6 6
2 1203.40 101 7.97 1829 6 6
3 1157.60 40 12.06 1773 6 7
4 767.76 40 12.90 1312 6 11
5 0.16 40 14.11 338 6 14
6 0.04 201 14.04 324 6 45

Cycle 129 GMT 5/12/2015 11:42: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.76 36 13.91 480 6 6
2 1509.32 101 8.65 2238 6 6
3 1427.64 41 11.87 2123 6 7
4 594.80 41 13.22 1078 6 11
5 0.04 40 14.17 333 6 19
6 -0.00 201 14.03 327 6 46

Cycle 128 GMT 30/11/2015 15:34: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.76 36 14.04 442 6 6
2 1516.76 101 8.50 2241 6 6
3 1437.60 41 11.82 2148 6 7
4 609.32 41 13.16 1101 6 11
5 0.08 40 14.19 322 6 17
6 0.04 201 14.08 312 6 44

Cycle 127 GMT 25/11/2015 19:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.84 36 13.97 480 6 6
2 1209.12 101 9.45 1846 6 6
3 1125.68 41 12.20 1765 6 8
4 222.32 41 13.72 613 6 12
5 0.24 40 14.17 322 6 19
6 0.20 201 14.05 308 6 48

Cycle 126 GMT 21/11/2015 0:51: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.40 36 14.04 442 6 6
2 1710.32 101 8.29 2476 6 6
3 1625.56 40 11.62 2381 6 6
4 808.00 40 12.91 1346 6 10
5 0.40 40 14.19 334 6 19
6 0.24 201 14.07 323 6 41

Cycle 125 GMT 15/11/2015 17:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.12 36 14.04 461 6 6
2 1705.88 101 8.24 2501 6 6
3 1620.28 40 11.61 2360 6 6
4 876.64 40 12.82 1426 6 10
5 3.04 40 14.16 339 6 25
6 -0.16 41 14.19 336 6 22
7 -0.12 200 14.07 321 6 54

Cycle 124 GMT 10/11/2015 9:59: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.88 36 13.97 461 6 6
2 1702.08 101 8.42 2466 6 6
3 1615.88 40 11.67 2367 6 7
4 889.76 40 12.78 1459 6 10
5 1.88 40 14.16 336 6 18
6 0.12 41 14.17 336 6 22
7 -0.00 200 14.07 320 6 51

Cycle 123 GMT 5/11/2015 2:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.80 36 14.04 461 6 6
2 1512.68 101 8.92 2245 6 6
3 1428.24 40 11.87 2143 6 8
4 464.44 40 13.39 909 6 12
5 0.36 40 14.16 332 6 19
6 0.28 201 14.03 317 6 44

Cycle 122 GMT 31/10/2015 6:30:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.72 36 13.97 461 6 6
2 1509.72 101 8.91 2236 6 6
3 1339.20 40 12.04 2034 6 7
4 432.20 40 13.44 875 6 11
5 -0.12 40 14.18 331 6 26
6 -0.16 201 14.02 319 6 51

Cycle 121 GMT 26/10/2015 10:14:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.72 36 13.97 461 6 6
2 1509.92 101 8.79 2250 6 6
3 1342.44 40 12.04 2012 6 7
4 424.08 40 13.44 870 6 11
5 -0.00 201 14.07 323 6 39

Cycle 120 GMT 21/10/2015 13:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 35 13.91 480 6 6
2 1206.36 101 9.60 1854 6 6
3 1123.12 41 12.29 1736 6 8
4 72.72 41 14.00 420 6 13
5 0.12 40 14.19 331 6 19
6 0.04 201 14.04 316 6 44

Cycle 119 GMT 16/10/2015 19:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 36 14.04 461 6 6
2 1709.00 101 8.53 2478 6 6
3 1528.36 40 11.84 2266 6 7
4 794.56 40 12.95 1330 6 11
5 0.24 201 14.11 312 6 33

Cycle 118 GMT 11/10/2015 11:51: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.80 36 13.97 480 6 6
2 1707.68 100 8.58 2459 6 6
3 1620.00 40 11.69 2352 6 6
4 863.36 40 12.85 1409 6 11
5 0.12 40 14.19 328 6 18
6 0.04 201 14.07 310 6 44

Cycle 117 GMT 6/10/2015 4:38:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.32 36 13.97 461 6 6
2 1708.80 101 8.63 2479 6 6
3 1434.72 40 12.01 2126 6 7
4 458.92 40 13.41 902 6 11
5 0.04 200 14.07 320 6 40

Cycle 116 GMT 30/ 9/2015 20:57: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.36 36 13.97 461 6 6
2 1509.76 101 9.18 2221 6 6
3 1424.68 40 11.99 2110 6 8
4 370.12 40 13.56 792 6 12
5 0.28 40 14.19 323 6 18
6 0.28 201 14.02 314 6 47

Cycle 115 GMT 26/ 9/2015 0:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.00 36 14.04 442 6 6
2 1505.16 101 9.15 2222 6 6
3 1420.52 40 11.99 2124 6 7
4 467.00 40 13.41 915 6 12
5 -0.00 40 14.22 322 6 16
6 -0.12 201 14.03 312 6 40

Cycle 114 GMT 21/ 9/2015 4:34: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.12 36 14.04 423 6 6
2 1511.64 101 9.10 2223 6 6
3 1428.80 40 11.96 2141 6 7
4 289.24 40 13.66 708 6 12
5 0.24 201 14.10 310 6 40

Cycle 113 GMT 16/ 9/2015 8:14: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.28 36 13.97 461 6 6
2 979.28 -1 13.97 461 6 6
3 1204.00 101 9.84 1841 6 6
4 1027.24 41 12.55 1638 6 8
5 3.16 41 14.17 331 6 12
6 0.04 41 14.20 317 6 23
7 0.08 200 14.07 306 6 47

Cycle 112 GMT 11/ 9/2015 13:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.52 35 14.10 442 6 6
2 1702.16 101 9.06 2451 6 6
3 1520.16 40 11.96 2249 6 8
4 473.68 40 13.44 939 6 11
5 0.12 40 14.22 331 6 20
6 0.12 201 14.05 314 6 46

Cycle 111 GMT 6/ 9/2015 6:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.68 36 14.04 461 6 6
2 982.64 -1 14.04 461 6 6
3 1703.56 101 9.08 2447 6 6
4 1527.00 40 11.94 2273 6 7
5 670.04 40 13.17 1172 6 12
6 0.36 40 14.24 320 6 22
7 -0.00 201 14.04 315 6 53

Cycle 110 GMT 31/ 8/2015 22:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.32 36 14.04 442 6 6
2 1704.12 101 8.97 2442 6 6
3 1432.36 40 12.06 2141 6 7
4 598.04 40 13.27 1088 6 11
5 16.12 40 14.18 344 6 19
6 -0.00 41 14.23 333 6 26
7 -0.12 200 14.03 319 6 51

Cycle 109 GMT 26/ 8/2015 15:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.36 36 14.10 423 6 6
2 1510.52 101 9.42 2217 6 6
3 1240.32 40 12.36 1873 6 9
4 368.56 40 13.57 788 6 13
5 0.20 40 14.25 315 6 13
6 0.16 201 14.03 309 6 45

Cycle 108 GMT 21/ 8/2015 19: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.04 36 13.97 461 6 6
2 1512.64 100 9.47 2214 6 6
3 1331.36 40 12.23 2002 6 8
4 275.24 40 13.74 683 6 13
5 0.08 40 14.23 323 6 19
6 -0.00 201 14.04 308 6 48

Cycle 107 GMT 16/ 8/2015 22:41: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.48 36 14.04 442 6 6
2 1508.20 101 9.38 2231 6 6
3 1330.36 40 12.25 1987 6 7
4 262.60 40 13.75 658 6 12
5 0.12 41 14.24 322 6 17
6 0.12 200 14.03 310 6 45

Cycle 106 GMT 12/ 8/2015 2:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.84 35 14.10 461 6 6
2 997.36 70 10.28 1545 6 7
3 262.40 30 13.75 656 6 11
4 -0.24 200 14.06 308 6 39

Cycle 105 GMT 7/ 8/2015 10:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.76 36 14.10 461 6 6
2 2003.60 71 5.19 2945 6 6
3 2062.72 30 11.78 2887 6 6
4 1991.68 30 11.92 2818 6 6
5 1601.48 30 12.38 2321 6 8
6 992.88 30 13.00 1571 6 10
7 75.84 30 14.12 422 6 13
8 0.08 201 14.16 309 6 44

Cycle 104 GMT 28/ 7/2015 9:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.36 36 14.04 442 6 6
2 2007.76 70 6.61 2876 6 6
3 1975.64 20 12.10 2821 6 6
4 1906.32 20 12.34 2725 6 6
5 1810.68 20 12.45 2597 6 7
6 1391.24 20 12.82 2098 6 8
7 966.88 20 13.21 1533 6 10
8 435.88 21 13.71 862 6 11
9 0.36 21 14.26 315 6 13
10 0.40 200 14.11 303 6 42

Cycle 103 GMT 18/ 7/2015 9:56: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.84 35 14.04 480 6 6
2 2008.36 71 7.57 2866 6 6
3 1952.48 21 12.06 2770 6 6
4 1866.00 21 12.26 2693 6 6
5 1661.20 21 12.45 2437 6 8
6 1220.28 21 12.90 1862 6 9
7 565.28 21 13.55 1031 6 10
8 53.96 21 14.19 390 6 13
9 -0.00 201 14.12 314 6 44

Cycle 102 GMT 8/ 7/2015 10:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.40 36 14.10 442 6 6
2 1510.96 70 9.79 2214 6 6
3 1440.76 21 12.54 2181 6 7
4 1248.04 21 12.80 1907 6 8
5 840.88 21 13.20 1403 6 10
6 196.04 21 13.88 606 6 11
7 0.16 20 14.26 338 6 11
8 -0.08 200 14.03 323 6 43

Cycle 101 GMT 3/ 7/2015 14: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 36 14.10 423 6 6
2 1513.40 70 9.76 2218 6 6
3 1445.72 21 12.54 2155 6 6
4 1349.08 21 12.70 2027 6 7
5 928.80 21 13.14 1497 6 9
6 160.28 21 13.98 544 6 11
7 28.32 21 14.20 360 6 13
8 0.12 21 14.28 328 6 15
9 0.20 200 14.06 309 6 46

Cycle 100 GMT 28/ 6/2015 17:35:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.04 36 13.97 442 6 6
2 1511.24 70 9.80 2235 6 6
3 1431.72 21 12.47 2157 6 7
4 1336.88 21 12.68 2023 6 7
5 915.64 21 13.12 1506 6 10
6 363.64 21 13.74 788 6 12
7 7.88 21 14.23 339 6 15
8 -0.00 21 14.25 330 6 17
9 -0.04 200 14.04 309 6 45

Cycle 99 GMT 23/ 6/2015 21:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.00 37 14.04 442 6 6
2 928.32 -2 14.04 442 6 6
3 1001.20 70 10.61 1558 6 7
4 339.08 21 13.64 764 6 10
5 0.08 201 14.06 304 6 35

Cycle 98 GMT 19/ 6/2015 5:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.24 36 14.10 423 6 6
2 979.36 -1 14.10 423 6 6
3 2003.20 71 8.42 2779 6 6
4 1924.96 21 12.06 2751 6 6
5 1825.96 21 12.28 2644 6 7
6 1412.92 21 12.69 2127 6 7
7 1080.92 21 13.03 1687 6 11
8 509.20 21 13.56 986 6 11
9 7.84 21 14.22 332 6 12
10 0.04 21 14.26 317 6 12
11 -0.04 200 14.07 302 6 48

Cycle 97 GMT 9/ 6/2015 6: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 36 14.04 461 6 6
2 2001.32 71 8.66 2785 6 6
3 1926.92 21 12.06 2743 6 6
4 1829.60 21 12.23 2659 6 6
5 1304.88 21 12.78 1984 6 8
6 886.00 21 13.20 1435 6 10
7 218.64 21 13.93 598 6 12
8 0.12 21 14.29 311 6 11
9 -0.00 200 14.06 307 6 41

Cycle 96 GMT 30/ 5/2015 6:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.08 36 14.10 442 6 6
2 2009.64 71 8.85 2803 6 6
3 1928.96 21 12.02 2760 6 6
4 1737.12 21 12.38 2527 6 7
5 1312.24 21 12.76 1982 6 8
6 667.52 21 13.41 1179 6 10
7 61.76 21 14.17 405 6 11
8 0.40 20 14.30 321 6 23
9 0.36 200 14.08 306 6 39

Cycle 95 GMT 20/ 5/2015 6:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.40 35 14.04 442 6 6
2 1512.72 70 10.31 2239 6 6
3 1448.64 20 12.60 2158 6 6
4 1250.04 20 12.89 1869 6 7
5 831.72 21 13.25 1354 6 10
6 192.20 21 13.96 561 6 11
7 39.16 21 14.19 386 6 14
8 -0.24 201 14.08 306 6 39

Cycle 94 GMT 15/ 5/2015 10:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.20 37 14.04 442 6 6
2 943.04 -2 14.04 442 6 6
3 1513.72 71 10.35 2226 6 6
4 1448.24 21 12.58 2151 6 6
5 1349.88 21 12.73 2042 6 8
6 827.20 21 13.24 1379 6 10
7 79.24 21 14.13 431 6 11
8 0.36 21 14.25 334 7 10
9 0.32 200 14.04 307 6 44

Cycle 93 GMT 10/ 5/2015 14: 4: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.04 31 14.04 442 6 6
2 1156.28 6 12.89 1807 6 6
3 1503.24 70 10.30 2215 6 6
4 1429.80 21 12.61 2129 6 7
5 1235.36 21 12.83 1894 6 8
6 814.16 21 13.25 1360 6 9
7 79.16 21 14.10 435 6 11
8 0.04 21 14.26 341 6 17
9 -0.20 200 14.00 321 6 39

Cycle 92 GMT 5/ 5/2015 17:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.44 30 14.17 423 6 6
2 1129.24 5 13.14 1750 6 6
3 1045.24 1 12.63 1692 6 6
4 1001.96 70 11.20 1561 6 7
5 426.04 21 13.60 852 6 11
6 0.36 21 14.24 319 6 12
7 0.32 200 13.98 305 6 39

Cycle 91 GMT 1/ 5/2015 2:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 36 14.04 442 6 6
2 2003.00 28 8.92 2793 6 6
3 1962.76 21 12.11 2740 6 6
4 1894.04 21 12.16 2700 6 6
5 1806.20 21 12.29 2604 6 7
6 1283.12 21 12.77 1946 6 9
7 761.28 21 13.31 1285 6 11
8 135.72 21 14.01 491 6 12
9 -0.16 21 14.28 311 6 20
10 -0.12 200 14.02 297 6 52

Cycle 90 GMT 21/ 4/2015 2:30: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.44 36 14.17 423 6 6
2 2009.44 28 9.36 2786 6 6
3 1975.16 21 11.99 2815 6 6
4 1905.80 21 12.19 2700 6 6
5 1809.72 21 12.25 2627 6 6
6 1373.64 21 12.74 2038 6 9
7 831.84 21 13.24 1356 6 10
8 277.68 21 13.85 655 6 11
9 0.40 20 14.27 307 6 15
10 0.32 200 14.01 303 6 39

Cycle 89 GMT 11/ 4/2015 2:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 36 14.10 442 6 6
2 2008.28 28 9.31 2823 6 6
3 1968.00 21 12.07 2762 6 6
4 1890.36 21 12.19 2700 6 6
5 1792.12 21 12.32 2572 6 6
6 1270.28 21 12.83 1899 6 9
7 647.96 21 13.39 1148 6 9
8 109.48 21 14.01 478 6 11
9 0.04 201 14.04 303 6 35

Cycle 88 GMT 1/ 4/2015 3: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.80 36 13.97 480 6 6
2 2007.00 28 9.52 2834 6 6
3 1964.64 21 12.08 2775 6 6
4 1882.36 21 12.23 2689 6 6
5 1677.64 21 12.41 2454 6 7
6 1269.64 21 12.81 1920 6 9
7 644.64 21 13.39 1142 6 10
8 114.36 21 14.02 480 6 11
9 -0.00 201 14.03 310 6 42

Cycle 87 GMT 22/ 3/2015 3: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.84 35 14.10 442 6 6
2 2004.12 28 9.76 2785 6 6
3 1957.44 21 12.09 2786 6 6
4 1879.20 21 12.19 2711 6 6
5 1781.48 21 12.33 2580 6 7
6 1239.56 21 12.81 1909 6 9
7 701.92 21 13.36 1217 6 10
8 68.80 21 14.11 422 6 12
9 0.16 21 14.24 339 6 21
10 0.04 200 13.95 319 6 40

Cycle 86 GMT 12/ 3/2015 3:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 36 14.04 461 6 6
2 981.36 -1 14.04 461 6 6
3 2008.36 28 9.88 2754 6 6
4 1956.20 21 12.11 2743 6 6
5 1871.68 21 12.22 2655 6 7
6 1773.44 21 12.32 2559 6 6
7 1245.64 21 12.87 1869 6 9
8 809.76 21 13.27 1345 6 11
9 71.52 21 14.08 433 6 12
10 0.08 21 14.24 326 6 16
11 -0.04 200 13.98 307 6 45

Cycle 85 GMT 2/ 3/2015 3:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.40 36 14.04 442 6 6
2 2007.52 28 9.68 2799 6 6
3 1972.52 21 12.10 2773 6 6
4 1893.84 21 12.19 2708 6 6
5 1697.32 21 12.45 2463 6 6
6 1281.56 21 12.81 1927 6 10
7 739.00 21 13.34 1249 6 10
8 196.72 21 13.92 580 6 12
9 0.08 21 14.28 315 6 14
10 -0.00 200 14.00 299 6 42

Cycle 84 GMT 20/ 2/2015 3:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.56 36 14.10 442 6 6
2 2004.60 28 9.75 2800 6 6
3 1963.56 21 12.10 2751 6 6
4 1891.00 21 12.19 2719 6 6
5 1602.08 21 12.48 2388 6 7
6 1503.12 21 12.57 2251 6 8
7 831.56 21 13.17 1409 6 11
8 85.48 21 14.08 425 6 11
9 0.04 21 14.25 326 6 12
10 -0.04 200 14.01 303 6 46

Cycle 83 GMT 10/ 2/2015 3:56: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.52 35 14.17 423 6 6
2 2002.00 28 9.98 2763 6 6
3 1959.00 21 12.07 2792 6 6
4 1878.88 21 12.24 2681 6 6
5 1684.04 21 12.48 2439 6 7
6 1276.52 21 12.83 1922 6 10
7 736.80 21 13.32 1262 6 10
8 47.12 21 14.14 390 6 11
9 0.28 20 14.31 326 6 15
10 0.24 200 14.00 312 6 42

Cycle 82 GMT 31/ 1/2015 3:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.04 36 14.10 442 6 6
2 981.96 -1 14.10 442 6 6
3 2007.00 28 9.97 2740 6 6
4 1971.80 21 12.07 2803 6 6
5 1895.48 21 12.18 2732 6 6
6 1698.96 21 12.45 2450 6 6
7 1281.92 21 12.84 1929 6 8
8 851.52 21 13.25 1394 6 11
9 80.76 21 14.11 420 6 11
10 -0.12 21 14.24 326 6 14
11 -0.12 200 13.99 305 6 42

Cycle 81 GMT 21/ 1/2015 4: 4: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.12 36 14.04 461 6 6
2 2002.64 28 9.91 2780 6 6
3 1965.04 21 12.13 2743 6 6
4 1886.60 21 12.21 2700 6 6
5 1691.04 21 12.37 2497 6 7
6 1377.32 21 12.73 2042 6 8
7 738.52 21 13.34 1247 6 10
8 83.64 21 14.13 416 6 11
9 0.36 21 14.24 326 6 20
10 0.20 200 13.99 304 6 44

Cycle 80 GMT 11/ 1/2015 4:15: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.36 34 14.10 423 6 6
2 1031.12 1 12.51 1615 6 6
3 2007.80 28 9.97 2752 6 6
4 1963.32 21 12.10 2758 6 6
5 1885.28 21 12.23 2694 6 6
6 1790.52 21 12.33 2576 6 7
7 1269.12 21 12.89 1894 6 8
8 836.40 21 13.25 1375 6 10
9 76.40 21 14.09 425 6 11
10 -0.08 21 14.29 317 6 16
11 -0.20 200 13.99 306 6 45

Cycle 79 GMT 1/ 1/2015 4:25: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.00 36 14.17 442 6 6
2 981.56 -1 14.17 442 6 6
3 2007.08 28 9.99 2745 6 6
4 1954.88 21 12.07 2796 6 6
5 1868.96 21 12.26 2651 6 6
6 1670.36 21 12.50 2394 6 6
7 1363.64 21 12.77 2029 6 8
8 816.44 21 13.23 1362 6 10
9 70.76 21 14.11 418 6 12
10 0.16 21 14.27 326 6 15
11 0.08 200 13.99 306 6 44

Cycle 78 GMT 22/12/2014 4:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 36 14.04 442 6 6
2 2002.84 28 9.76 2799 6 6
3 1954.32 21 12.10 2753 6 6
4 1878.88 21 12.27 2646 6 6
5 1783.08 21 12.36 2576 6 6
6 1262.72 21 12.86 1897 6 8
7 941.28 21 13.15 1512 6 10
8 266.32 21 13.81 672 6 11
9 0.92 201 14.03 306 6 35

Cycle 77 GMT 12/12/2014 5: 1: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.08 36 14.10 442 6 6
2 2008.88 28 9.66 2807 6 6
3 1961.04 21 12.11 2790 6 6
4 1876.48 21 12.24 2679 6 6
5 1679.76 21 12.47 2439 6 6
6 1363.32 21 12.79 2010 6 8
7 1036.64 21 13.02 1621 6 10
8 126.24 21 14.02 480 6 11
9 0.36 200 14.03 304 6 43

Cycle 76 GMT 2/12/2014 5:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.04 35 13.97 480 6 6
2 2006.00 28 9.69 2805 6 6
3 1963.68 21 12.15 2751 6 6
4 1888.08 21 12.19 2711 6 6
5 1698.52 21 12.46 2467 6 6
6 1283.00 21 12.82 1941 6 8
7 751.28 21 13.32 1275 6 9
8 48.32 21 14.13 392 6 11
9 -0.04 21 14.28 326 6 14
10 -0.04 200 13.99 307 6 38

Cycle 75 GMT 22/11/2014 5:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 35 14.04 461 6 6
2 2000.88 28 9.85 2761 6 6
3 1963.72 21 12.04 2826 6 6
4 1888.88 21 12.23 2706 6 6
5 1590.52 21 12.51 2362 6 7
6 1278.72 21 12.80 1952 6 9
7 656.60 21 13.42 1164 6 10
8 48.12 21 14.07 405 6 11
9 0.72 200 13.97 324 6 40

Cycle 74 GMT 12/11/2014 5:37: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.12 35 14.04 461 6 6
2 2007.08 28 9.74 2776 6 6
3 1962.76 21 12.07 2794 6 6
4 1883.68 21 12.19 2713 6 6
5 1687.04 21 12.45 2448 6 6
6 1270.24 21 12.81 1931 6 9
7 734.20 21 13.32 1262 6 10
8 80.08 21 14.05 448 6 11
9 -0.04 20 14.25 328 6 19
10 -0.08 200 13.92 315 6 39

Cycle 73 GMT 2/11/2014 5:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.00 35 14.04 442 6 6
2 2004.12 28 9.93 2745 6 6
3 1956.48 21 12.07 2798 6 6
4 1874.76 21 12.22 2702 6 6
5 1675.88 21 12.45 2487 6 7
6 1254.04 21 12.81 1941 6 9
7 719.48 21 13.32 1262 6 10
8 390.24 21 13.66 843 6 12
9 0.16 21 14.18 345 6 16
10 0.16 200 13.89 322 6 42

Cycle 72 GMT 23/10/2014 6: 6: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 35 14.04 461 6 6
2 2002.64 28 9.80 2772 6 6
3 1959.32 21 12.09 2771 6 6
4 1872.92 21 12.24 2672 6 6
5 1775.00 21 12.34 2587 6 6
6 1145.28 21 12.93 1760 6 8
7 733.88 21 13.32 1258 6 9
8 84.00 21 14.08 427 6 12
9 0.24 21 14.27 323 6 12
10 0.12 200 13.93 309 6 40

Cycle 71 GMT 13/10/2014 6:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.20 35 14.04 442 6 6
2 2003.52 28 9.91 2750 6 6
3 1954.12 21 12.05 2794 6 6
4 1874.32 21 12.23 2679 6 6
5 1775.56 21 12.31 2584 6 7
6 1343.48 21 12.71 2044 6 8
7 799.08 21 13.25 1349 6 10
8 64.92 21 14.10 405 6 12
9 0.24 21 14.27 332 6 15
10 0.08 200 13.92 311 6 48

Cycle 70 GMT 3/10/2014 6:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.16 35 14.17 423 6 6
2 2006.60 28 9.87 2734 6 6
3 1958.40 21 12.10 2730 6 6
4 1880.04 21 12.22 2700 6 6
5 1788.76 21 12.37 2550 6 6
6 1267.24 21 12.85 1916 6 8
7 738.20 21 13.32 1262 6 10
8 294.52 21 13.78 717 6 11
9 0.32 20 14.23 331 6 11
10 0.24 200 13.92 309 6 38

Cycle 69 GMT 23/ 9/2014 7: 1: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.64 35 13.97 442 6 6
2 2002.84 28 9.92 2712 6 6
3 1953.56 21 12.05 2796 6 6
4 1874.80 21 12.24 2672 6 6
5 1780.76 21 12.35 2548 6 7
6 1351.32 21 12.78 2016 6 8
7 796.76 21 13.28 1324 6 11
8 142.80 21 13.98 512 6 12
9 -0.24 21 14.25 321 6 12
10 -0.24 200 13.93 300 6 37

Cycle 68 GMT 13/ 9/2014 7:26:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.96 36 13.97 480 6 6
2 982.12 -1 13.97 480 6 6
3 2004.64 28 9.93 2743 6 6
4 1952.88 21 12.04 2794 6 6
5 1867.52 21 12.21 2704 6 6
6 1670.56 21 12.48 2412 6 7
7 1258.16 21 12.85 1911 6 9
8 926.52 21 13.14 1497 6 11
9 249.84 21 13.86 638 6 11
10 0.16 201 13.99 301 6 37

Cycle 67 GMT 3/ 9/2014 7:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.56 36 14.17 423 6 6
2 2004.40 28 9.80 2714 6 6
3 1958.52 21 12.06 2756 6 6
4 1872.08 21 12.25 2649 6 6
5 1670.96 21 12.45 2446 6 6
6 1253.88 21 12.85 1882 6 8
7 636.36 21 13.45 1125 6 10
8 101.12 21 14.05 456 6 11
9 0.24 21 14.25 326 6 9
10 0.24 200 13.94 306 6 43

Cycle 66 GMT 24/ 8/2014 7:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 35 14.10 442 6 6
2 2006.80 28 9.82 2713 6 6
3 1961.24 21 12.05 2790 6 6
4 1881.64 21 12.23 2687 6 6
5 1784.12 21 12.35 2563 6 7
6 1258.76 21 12.85 1911 6 8
7 937.36 21 13.12 1521 6 10
8 150.52 21 13.96 529 6 12
9 5.00 21 14.24 330 6 12
10 0.12 21 14.22 322 6 21
11 0.08 200 13.90 306 6 39

Cycle 65 GMT 14/ 8/2014 8: 2: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 35 14.10 461 6 6
2 2000.64 28 9.81 2697 6 6
3 1963.80 21 12.00 2800 6 6
4 1890.72 21 12.19 2745 6 6
5 1797.68 21 12.37 2580 6 7
6 1268.60 21 12.78 1961 6 8
7 741.56 21 13.34 1264 6 9
8 86.36 21 14.08 437 6 11
9 -0.16 21 14.30 324 6 21
10 -0.16 200 13.96 303 6 42

Cycle 64 GMT 4/ 8/2014 8:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 35 14.17 442 6 6
2 2004.76 28 9.47 2784 6 6
3 1958.64 21 12.04 2794 6 6
4 1872.16 21 12.24 2661 6 6
5 1676.24 21 12.46 2471 6 7
6 1264.56 21 12.81 1939 6 8
7 843.48 21 13.22 1403 6 10
8 81.52 21 14.07 439 6 11
9 0.48 21 14.28 337 6 13
10 0.36 200 13.95 313 6 50

Cycle 63 GMT 25/ 7/2014 8:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 35 14.10 461 6 6
2 2008.28 28 9.47 2763 6 6
3 1958.96 21 12.09 2770 6 6
4 1876.12 21 12.18 2736 6 6
5 1678.36 21 12.49 2439 6 7
6 1367.72 21 12.74 2078 6 9
7 721.16 21 13.37 1243 6 10
8 293.52 21 13.80 711 6 12
9 30.12 21 14.20 365 6 13
10 -0.12 21 14.28 319 6 15
11 -0.24 200 13.95 305 6 45

Cycle 62 GMT 15/ 7/2014 8:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.20 35 14.10 461 6 6
2 2003.12 28 9.39 2772 6 6
3 1958.52 21 12.02 2805 6 6
4 1884.12 21 12.25 2692 6 7
5 1789.96 21 12.33 2599 6 7
6 1165.56 21 12.93 1792 6 8
7 751.00 21 13.35 1273 6 10
8 110.76 21 14.06 469 6 12
9 0.20 21 14.32 317 6 19
10 0.24 200 13.97 304 6 45

Cycle 61 GMT 5/ 7/2014 8:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 35 14.17 442 6 6
2 2003.24 28 9.40 2752 6 6
3 1957.48 21 12.12 2766 6 6
4 1875.08 21 12.23 2698 6 6
5 1679.12 21 12.49 2452 6 7
6 1167.36 21 12.90 1839 6 9
7 751.04 21 13.33 1285 6 11
8 52.76 21 14.14 409 6 11
9 -0.20 200 13.99 318 6 42

Cycle 60 GMT 25/ 6/2014 8:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.64 35 14.17 442 6 6
2 2007.52 28 9.32 2721 6 6
3 1965.08 21 12.08 2792 6 6
4 1882.24 21 12.24 2691 6 6
5 1686.60 21 12.53 2456 6 7
6 1285.04 21 12.87 1935 6 9
7 654.04 21 13.43 1138 6 10
8 120.80 21 14.08 467 6 11
9 0.28 201 14.03 305 6 43

Cycle 59 GMT 15/ 6/2014 8:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.04 35 14.10 480 6 6
2 2010.44 28 9.24 2727 6 6
3 1978.44 21 12.05 2830 6 6
4 1903.56 21 12.21 2732 6 6
5 1714.88 21 12.50 2512 6 7
6 1293.08 21 12.84 1961 6 8
7 860.28 21 13.27 1409 6 10
8 56.64 21 14.16 396 6 11
9 -0.00 21 14.31 330 6 18
10 -0.04 200 13.98 309 6 46

Cycle 58 GMT 5/ 6/2014 8:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.40 35 14.17 442 6 6
2 2002.76 28 8.93 2781 6 6
3 1956.36 21 12.08 2794 6 6
4 1874.36 21 12.25 2687 6 6
5 1677.16 21 12.52 2450 6 7
6 1353.88 21 12.80 2029 6 9
7 606.28 21 13.51 1089 6 9
8 186.44 21 13.98 567 6 11
9 0.24 20 14.30 333 6 14
10 0.16 200 13.94 316 6 40

Cycle 57 GMT 26/ 5/2014 9: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.96 35 14.17 442 6 6
2 2008.52 28 8.96 2713 6 6
3 1970.48 21 12.08 2809 6 6
4 1889.88 21 12.28 2687 6 6
5 1696.76 21 12.50 2501 6 7
6 1373.76 21 12.80 2072 6 9
7 722.68 21 13.43 1213 6 9
8 191.76 21 13.95 576 6 11
9 31.84 21 14.25 356 6 14
10 0.16 21 14.30 315 6 17
11 0.08 200 13.96 303 6 45

Cycle 56 GMT 16/ 5/2014 9:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.60 35 14.17 442 6 6
2 2004.52 28 8.88 2740 6 6
3 1968.24 21 12.08 2781 6 6
4 1899.84 21 12.26 2734 6 6
5 1811.28 21 12.37 2591 6 6
6 1391.32 21 12.79 2076 6 8
7 859.84 21 13.25 1429 6 10
8 293.36 21 13.84 702 6 11
9 -0.00 21 14.31 317 6 10
10 -0.04 200 13.99 300 6 36

Cycle 55 GMT 6/ 5/2014 9:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.44 35 14.17 442 6 6
2 2006.40 28 8.88 2813 6 6
3 1971.12 21 12.10 2783 6 6
4 1896.64 21 12.26 2698 6 6
5 1698.60 21 12.53 2463 6 6
6 1385.96 21 12.80 2061 6 8
7 1047.60 21 13.06 1659 6 10
8 254.52 21 13.88 659 6 11
9 0.60 201 14.03 311 6 38

Cycle 54 GMT 26/ 4/2014 10:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 35 14.23 423 6 6
2 2009.64 28 8.96 2800 6 6
3 1973.48 21 12.08 2807 6 6
4 1902.84 21 12.26 2706 6 6
5 1810.92 21 12.40 2568 6 6
6 1188.68 21 12.95 1820 6 8
7 877.96 21 13.26 1426 6 10
8 112.00 21 14.10 469 6 10
9 7.60 21 14.32 321 6 14
10 0.08 21 14.29 313 6 21
11 0.08 200 13.97 299 6 40

Cycle 53 GMT 16/ 4/2014 10:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.24 35 14.17 461 6 6
2 2003.08 28 9.23 2758 6 6
3 1963.44 21 12.10 2803 6 6
4 1894.16 21 12.26 2706 6 6
5 1806.16 21 12.35 2593 6 7
6 1363.96 21 12.86 2025 6 9
7 814.44 21 13.33 1337 6 10
8 158.08 21 14.03 525 6 12
9 -0.00 21 14.39 311 6 11
10 -0.04 200 14.03 299 6 40

Cycle 52 GMT 6/ 4/2014 10:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.08 35 14.29 423 6 6
2 2007.72 28 9.25 2861 6 6
3 1963.68 21 12.12 2798 6 6
4 1884.84 21 12.25 2704 6 6
5 1790.56 21 12.41 2544 6 6
6 1257.04 21 12.93 1922 6 8
7 724.32 21 13.44 1243 6 10
8 155.24 21 14.05 533 6 12
9 0.40 21 14.35 332 6 24
10 0.28 200 13.98 317 6 40

Cycle 51 GMT 27/ 3/2014 10:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.44 35 14.29 442 6 6
2 2001.92 28 9.63 2802 6 6
3 1962.52 21 12.15 2783 6 6
4 1880.56 21 12.30 2675 6 6
5 1682.64 21 12.59 2405 6 7
6 1265.88 21 12.93 1909 6 9
7 629.32 21 13.54 1117 6 10
8 90.84 21 14.16 431 6 11
9 -0.16 21 14.36 307 6 9
10 -0.28 200 14.03 295 6 48

Cycle 50 GMT 17/ 3/2014 10:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.20 35 14.29 423 6 6
2 2005.52 28 10.05 2790 6 6
3 1960.88 21 12.15 2775 6 6
4 1880.88 21 12.26 2726 6 6
5 1679.12 21 12.59 2429 6 7
6 1149.84 21 13.07 1758 6 8
7 733.52 21 13.43 1262 6 10
8 38.08 21 14.25 386 6 11
9 0.36 201 14.04 314 6 36

Cycle 49 GMT 7/ 3/2014 11:14: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.36 35 14.17 480 6 6
2 2001.92 28 10.07 2829 6 6
3 1961.64 21 12.12 2841 6 6
4 1887.72 21 12.25 2721 6 6
5 1695.20 21 12.62 2433 6 7
6 1174.16 21 13.04 1796 6 9
7 742.00 21 13.48 1243 6 10
8 78.48 21 14.20 431 6 12
9 0.04 21 14.36 315 6 11
10 -0.04 200 14.03 299 6 40

Cycle 48 GMT 25/ 2/2014 11:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 35 14.29 442 6 6
2 2005.04 28 10.19 2895 6 6
3 1951.32 21 12.16 2779 6 6
4 1870.80 21 12.31 2679 6 6
5 1779.28 21 12.37 2606 6 7
6 1229.72 21 12.98 1899 6 8
7 590.76 21 13.57 1112 6 10
8 38.24 21 14.23 396 6 12
9 0.12 20 14.37 346 6 12
10 0.12 200 14.00 324 6 39

Cycle 47 GMT 15/ 2/2014 11:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.00 35 14.29 442 6 6
2 2005.64 28 10.68 2818 6 6
3 1949.96 20 12.26 2807 6 6
4 1865.80 20 12.40 2689 6 6
5 1664.84 20 12.69 2432 6 7
6 1249.96 20 13.04 1903 6 9
7 817.48 20 13.44 1367 6 9
8 143.28 21 14.10 516 6 12
9 0.12 21 14.39 315 6 15
10 0.08 200 14.04 299 6 43

Cycle 46 GMT 5/ 2/2014 12: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 34 14.29 461 6 6
2 2003.84 28 10.82 2789 6 6
3 1954.48 21 12.19 2798 6 6
4 1874.48 21 12.36 2666 6 6
5 1477.12 21 12.86 2183 6 7
6 1069.76 21 13.20 1655 6 8
7 540.12 21 13.70 1008 6 10
8 39.16 21 14.26 373 6 13
9 -0.04 201 14.05 306 6 39

Cycle 45 GMT 26/ 1/2014 12: 5: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.88 34 14.29 442 6 6
2 2005.80 28 10.96 2812 6 6
3 1948.12 21 12.28 2760 6 6
4 1861.12 21 12.41 2657 6 6
5 1558.72 21 12.78 2309 6 7
6 1146.12 21 13.10 1798 6 9
7 600.24 21 13.61 1117 6 10
8 58.00 21 14.24 416 6 12
9 0.20 21 14.37 345 6 20
10 0.12 200 14.02 317 6 41

Cycle 44 GMT 16/ 1/2014 12:19: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.44 34 14.29 461 6 6
2 2003.00 28 10.95 2831 6 6
3 1951.68 21 12.32 2766 6 6
4 1865.24 21 12.39 2679 6 6
5 1660.84 21 12.71 2435 6 7
6 1127.80 21 13.17 1751 6 8
7 689.32 21 13.60 1172 6 11
8 28.04 21 14.31 356 6 11
9 0.08 21 14.32 326 6 11
10 -0.04 200 14.00 307 6 46

Cycle 43 GMT 6/ 1/2014 12:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.24 34 14.29 461 6 6
2 2008.96 28 10.94 2902 6 6
3 1954.24 21 12.33 2796 6 6
4 1871.60 21 12.45 2674 6 6
5 1570.20 21 12.83 2309 6 8
6 1146.20 21 13.17 1796 6 10
7 601.36 21 13.65 1110 6 10
8 57.48 21 14.24 418 6 12
9 0.04 20 14.39 333 6 17
10 -0.08 200 14.02 318 6 47

Cycle 42 GMT 27/12/2013 12:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.40 34 14.29 461 6 6
2 2004.24 28 11.11 2914 6 6
3 1949.84 21 12.36 2783 6 6
4 1862.24 21 12.44 2681 6 6
5 1554.40 21 12.91 2247 6 7
6 1128.56 21 13.20 1762 6 9
7 458.84 21 13.80 924 6 11
8 47.80 21 14.26 409 6 12
9 0.72 201 14.04 327 6 40

Cycle 41 GMT 17/12/2013 13: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.00 34 14.29 461 6 6
2 2008.36 28 11.67 2867 6 6
3 1957.88 21 12.36 2803 6 6
4 1871.36 21 12.47 2689 6 6
5 1563.56 21 12.88 2264 6 7
6 1027.68 21 13.30 1610 6 9
7 508.92 21 13.79 956 6 10
8 31.56 21 14.30 369 6 12
9 0.04 21 14.32 334 6 14
10 -0.00 200 14.01 312 6 46

Cycle 40 GMT 7/12/2013 13:23:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.92 34 14.29 461 6 6
2 2001.72 28 11.95 2849 6 6
3 1948.04 21 12.46 2732 6 6
4 1858.00 21 12.47 2672 6 7
5 1549.20 21 12.90 2277 6 7
6 1118.52 21 13.23 1730 6 10
7 470.56 21 13.83 914 6 10
8 10.76 21 14.35 341 6 12
9 0.16 20 14.29 338 6 16
10 0.12 200 14.01 308 6 44

Cycle 39 GMT 27/11/2013 13:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.04 34 14.29 461 6 6
2 2007.68 28 12.24 2845 6 6
3 1945.56 21 12.46 2798 6 6
4 1859.20 21 12.54 2657 6 6
5 1552.20 21 12.87 2339 6 7
6 998.68 21 13.35 1578 6 9
7 446.56 21 13.85 909 6 11
8 18.48 21 14.34 358 6 12
9 0.20 21 14.36 334 6 13
10 0.04 200 14.03 311 6 44

Cycle 38 GMT 17/11/2013 14:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 34 14.29 461 6 6
2 2004.28 28 12.39 2840 6 6
3 1943.92 21 12.51 2764 6 7
4 1859.48 20 12.61 2670 6 6
5 1462.36 21 13.00 2177 6 8
6 1044.52 21 13.28 1653 6 9
7 411.80 21 13.87 860 6 11
8 -0.00 20 14.42 326 6 12
9 -0.08 200 14.07 308 6 38

Cycle 37 GMT 7/11/2013 14:28: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 34 14.29 461 6 6
2 2006.44 28 12.56 2850 6 6
3 1948.36 20 12.53 2826 6 6
4 1863.32 21 12.56 2692 6 7
5 1550.12 21 12.98 2270 6 8
6 1012.84 21 13.34 1621 6 9
7 465.00 21 13.84 920 6 10
8 0.28 21 14.38 337 6 9
9 0.24 200 14.06 313 6 44

Cycle 36 GMT 28/10/2013 14:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 34 14.29 461 6 6
2 2002.76 28 12.67 2854 6 6
3 1939.36 20 12.61 2773 6 6
4 1850.64 20 12.63 2691 6 6
5 1546.36 20 13.02 2276 6 7
6 1218.00 20 13.23 1862 6 9
7 561.80 20 13.78 1059 6 11
8 24.12 20 14.37 369 6 11
9 0.04 21 14.37 343 6 17
10 -0.12 200 14.03 324 6 40

Cycle 35 GMT 18/10/2013 14:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.28 34 14.36 442 6 6
2 2005.00 28 12.73 2823 6 6
3 1940.92 21 12.57 2805 6 6
4 1851.24 21 12.61 2672 6 6
5 1446.44 21 13.05 2174 6 8
6 1013.88 21 13.40 1595 6 9
7 455.52 21 13.89 905 6 11
8 0.28 21 14.48 317 6 13
9 0.28 200 14.12 304 6 45

Cycle 34 GMT 8/10/2013 15:15: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.76 34 14.36 442 6 6
2 2003.12 28 12.84 2829 6 6
3 1937.60 20 12.69 2749 6 6
4 1854.16 20 12.72 2629 6 7
5 1558.72 20 13.03 2312 6 7
6 1038.08 20 13.39 1651 6 8
7 515.72 20 13.86 1004 6 11
8 0.20 21 14.41 321 6 12
9 0.16 200 14.09 309 6 41

Cycle 33 GMT 28/ 9/2013 15:22: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.00 34 14.29 461 6 6
2 2003.40 29 12.78 2855 6 6
3 1940.12 20 12.69 2816 6 6
4 1849.24 20 12.73 2665 6 7
5 1431.44 20 13.13 2143 6 8
6 1012.00 20 13.47 1612 6 9
7 488.16 20 13.91 946 6 10
8 12.00 20 14.42 333 6 11
9 -0.04 21 14.39 315 6 15
10 -0.08 200 14.08 304 6 38

Cycle 32 GMT 18/ 9/2013 15:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 33 14.42 442 6 6
2 2006.96 29 12.84 2828 6 6
3 1945.92 20 12.74 2783 6 6
4 1855.72 20 12.81 2610 6 7
5 1431.32 20 13.21 2098 6 7
6 919.24 20 13.52 1499 6 10
7 487.88 20 13.95 951 6 10
8 65.88 20 14.34 420 6 12
9 0.16 21 14.44 328 6 16
10 0.04 200 14.10 310 6 41

Cycle 31 GMT 8/ 9/2013 15:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.36 34 14.36 442 6 6
2 976.84 -1 14.36 442 6 6
3 2000.68 29 12.90 2825 6 6
4 1931.00 20 12.81 2737 6 6
5 1835.48 20 12.86 2590 6 7
6 1425.92 20 13.23 2093 6 8
7 1097.76 20 13.48 1672 6 8
8 331.88 20 14.10 727 6 10
9 4.28 20 14.45 326 6 10
10 0.04 21 14.44 315 6 16
11 0.12 200 14.11 304 6 41

Cycle 30 GMT 29/ 8/2013 16:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.60 34 14.42 442 6 6
2 2004.08 29 12.93 2836 6 6
3 1932.64 20 12.84 2768 6 6
4 1839.36 20 12.88 2624 6 6
5 1429.80 20 13.26 2124 6 7
6 998.24 20 13.55 1569 6 10
7 376.20 20 14.06 797 6 10
8 0.24 21 14.52 309 6 11
9 0.20 200 14.17 294 6 40

Cycle 29 GMT 19/ 8/2013 16:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 34 14.42 442 6 6
2 2004.32 28 13.03 2858 6 6
3 1927.60 20 12.88 2761 6 6
4 1828.64 20 12.93 2595 6 7
5 1516.88 20 13.25 2184 6 8
6 984.72 20 13.59 1564 6 9
7 358.84 20 14.12 764 6 10
8 24.04 20 14.49 338 6 11
9 -0.12 21 14.47 315 6 16
10 -0.12 200 14.14 294 6 42

Cycle 28 GMT 9/ 8/2013 16:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.48 34 14.42 442 6 6
2 2009.32 28 13.00 2858 6 6
3 1946.04 20 12.91 2768 6 6
4 1856.44 20 12.89 2699 6 6
5 1544.80 20 13.21 2295 6 8
6 1017.04 20 13.59 1605 6 9
7 395.24 20 14.11 826 6 10
8 0.08 21 14.53 343 6 12
9 0.08 200 14.14 316 6 40

Cycle 27 GMT 30/ 7/2013 16:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 34 14.42 442 6 6
2 2005.80 29 13.03 2813 6 6
3 1939.32 20 12.94 2744 6 6
4 1744.64 20 13.14 2494 6 7
5 1437.64 20 13.32 2134 6 8
6 907.56 20 13.69 1475 6 11
7 273.96 20 14.20 706 6 11
8 0.72 200 14.19 315 6 34

Cycle 26 GMT 20/ 7/2013 17:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 33 14.42 461 6 6
2 2000.92 29 13.02 2833 6 6
3 1932.60 20 12.95 2761 6 6
4 1741.76 20 13.16 2509 6 6
5 1445.32 20 13.34 2112 6 9
6 1018.96 20 13.63 1590 6 9
7 276.56 20 14.23 687 6 10
8 13.08 20 14.54 326 6 11
9 0.08 21 14.47 315 6 12
10 0.08 200 14.16 298 6 42

Cycle 25 GMT 10/ 7/2013 17:37:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 34 14.42 423 6 6
2 978.56 -1 14.42 423 6 6
3 2003.68 28 13.11 2823 6 7
4 1936.88 20 13.02 2723 6 6
5 1846.48 20 12.98 2665 6 7
6 1420.56 20 13.36 2117 6 7
7 1001.40 20 13.65 1581 6 10
8 463.44 20 14.06 922 6 11
9 23.04 20 14.51 357 6 12
10 0.24 20 14.52 326 6 12
11 0.16 200 14.16 303 6 40

Cycle 24 GMT 30/ 6/2013 17:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.92 34 14.42 442 6 6
2 2002.56 29 13.07 2836 6 6
3 1929.36 20 13.00 2737 6 6
4 1830.72 20 13.00 2624 6 7
5 1408.00 20 13.40 2076 6 8
6 895.76 20 13.73 1456 6 9
7 269.76 20 14.28 667 6 10
8 0.36 20 14.62 304 6 12
9 0.32 200 14.21 291 6 37

Cycle 23 GMT 20/ 6/2013 18:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 34 14.42 442 6 6
2 2001.72 28 13.11 2852 6 6
3 1939.32 20 13.02 2749 6 6
4 1843.36 20 13.03 2617 6 7
5 1519.64 20 13.34 2208 6 8
6 1195.60 20 13.54 1802 6 10
7 530.04 20 14.05 982 6 10
8 30.48 20 14.55 353 6 10
9 -0.28 21 14.54 315 6 10
10 -0.24 200 14.18 299 6 41

Cycle 22 GMT 10/ 6/2013 18:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.44 34 14.48 423 6 6
2 2002.32 29 13.11 2796 6 6
3 1942.44 20 12.98 2754 6 7
4 1853.64 20 13.03 2626 6 7
5 1438.36 20 13.36 2122 6 9
6 1010.92 20 13.67 1586 6 9
7 249.48 20 14.32 631 6 10
8 6.60 20 14.57 321 6 11
9 0.20 21 14.51 307 6 20
10 0.08 200 14.18 300 6 41

Cycle 21 GMT 31/ 5/2013 18:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 34 14.48 423 6 6
2 2005.00 29 13.11 2794 6 6
3 1938.68 20 13.01 2725 6 6
4 1846.64 20 13.07 2626 6 6
5 1417.64 20 13.37 2093 6 8
6 1096.12 20 13.62 1679 6 10
7 426.72 20 14.14 852 6 10
8 0.16 21 14.64 292 6 11
9 0.12 200 14.22 286 6 42

Cycle 20 GMT 21/ 5/2013 19:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 34 14.48 423 6 6
2 2003.52 29 13.06 2821 6 6
3 1938.72 20 13.03 2708 6 6
4 1746.96 20 13.19 2456 6 7
5 1430.48 20 13.38 2098 6 8
6 893.84 20 13.76 1437 6 9
7 361.48 20 14.22 769 6 10
8 0.12 21 14.62 302 6 10
9 0.20 200 14.23 283 6 37

Cycle 19 GMT 11/ 5/2013 19:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.92 34 14.55 403 6 6
2 2007.60 29 13.05 2812 6 6
3 1939.84 20 13.01 2730 6 6
4 1849.44 20 13.06 2605 6 7
5 1426.64 20 13.37 2103 6 8
6 1003.36 20 13.68 1564 6 9
7 358.84 20 14.22 757 6 11
8 0.16 201 14.28 284 6 37

Cycle 18 GMT 1/ 5/2013 19:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.92 34 14.55 403 6 6
2 2004.40 29 13.05 2813 6 6
3 1935.84 20 12.98 2718 6 6
4 1838.36 20 13.07 2569 6 7
5 1521.44 20 13.30 2218 6 7
6 868.68 20 13.76 1408 6 10
7 346.24 20 14.23 749 6 11
8 0.08 21 14.69 290 6 14
9 -0.04 200 14.25 282 6 35

Cycle 17 GMT 21/ 4/2013 19:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 34 14.61 384 6 6
2 2004.24 29 13.04 2792 6 6
3 1941.04 20 12.99 2744 6 6
4 1850.96 20 13.05 2600 6 7
5 1524.64 20 13.27 2211 6 8
6 979.36 20 13.70 1518 6 9
7 334.48 20 14.23 735 6 11
8 0.16 21 14.70 294 6 11
9 0.04 200 14.26 282 6 36

Cycle 16 GMT 11/ 4/2013 20:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 34 14.55 403 6 6
2 2002.24 29 13.07 2801 6 6
3 1938.72 20 12.97 2742 6 7
4 1849.72 20 13.07 2595 6 7
5 1427.52 20 13.34 2110 6 8
6 886.04 20 13.78 1401 6 9
7 269.16 20 14.30 646 6 10
8 31.40 20 14.62 328 6 11
9 -0.00 21 14.63 292 6 15
10 -0.08 200 14.24 274 6 42

Cycle 15 GMT 1/ 4/2013 20:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.64 34 14.55 403 6 6
2 2001.48 29 13.09 2779 6 6
3 1931.96 20 13.04 2703 6 6
4 1839.80 20 13.07 2607 6 7
5 1327.64 20 13.43 1951 6 9
6 919.20 20 13.75 1439 6 10
7 263.28 20 14.34 629 6 11
8 26.76 20 14.62 323 6 12
9 -0.00 21 14.65 283 6 9
10 0.04 200 14.24 277 6 42

Cycle 14 GMT 22/ 3/2013 20:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.24 34 14.55 403 6 6
2 2000.56 62 12.64 2792 6 7
3 1546.88 25 13.26 2201 6 8
4 870.92 25 13.73 1380 6 10
5 177.44 25 14.40 517 6 11
6 0.28 25 14.70 291 6 13
7 0.24 251 14.24 278 6 53

Cycle 13 GMT 12/ 3/2013 20:43: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.44 33 14.55 403 6 6
2 2000.64 62 12.66 2800 6 6
3 1559.04 25 13.23 2243 6 9
4 894.08 25 13.70 1405 6 10
5 192.44 25 14.38 545 6 11
6 26.16 25 14.59 336 6 13
7 -0.00 25 14.61 293 6 17
8 0.04 247 14.22 279 6

Cycle 12 GMT 2/ 3/2013 20:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 33 14.55 403 6 6
2 2007.00 62 12.65 2827 6 6
3 1545.36 25 13.25 2216 6 8
4 849.48 25 13.71 1370 6 10
5 170.80 25 14.40 515 6 11
6 -0.08 25 14.72 289 6 12
7 -0.12 251 14.23 279 6 54

Cycle 11 GMT 20/ 2/2013 21:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.08 33 14.55 403 6 6
2 2007.56 62 12.69 2805 6 6
3 1544.84 25 13.24 2226 6 7
4 860.52 25 13.70 1395 6 9
5 162.04 25 14.43 501 6 10
6 0.16 25 14.72 289 6 12
7 0.12 251 14.24 278 6 59

Cycle 10 GMT 10/ 2/2013 21:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.68 33 14.55 403 6 6
2 2007.40 62 12.70 2807 6 6
3 1564.48 25 13.26 2232 6 7
4 891.12 25 13.71 1403 6 8
5 192.16 25 14.38 547 6 10
6 -0.00 24 14.73 286 6 15
7 -0.00 251 14.24 278 6 56

Cycle 9 GMT 31/ 1/2013 21:24: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 33 14.55 423 6 6
2 2006.32 62 12.71 2810 6 6
3 1530.44 25 13.21 2230 6 6
4 838.52 25 13.73 1360 6 8
5 160.20 25 14.44 507 6 10
6 0.56 250 14.29 280 6 40

Cycle 8 GMT 21/ 1/2013 21:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.68 33 14.55 403 6 6
2 2000.72 62 12.73 2799 6 6
3 1548.16 25 13.23 2215 6 6
4 861.28 25 13.69 1388 6 8
5 153.88 25 14.45 495 6 10
6 0.12 25 14.73 291 6 18
7 -0.04 251 14.25 275 6 59

Cycle 7 GMT 11/ 1/2013 21:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.32 32 14.61 403 6 6
2 2007.04 62 12.73 2801 6 6
3 1357.44 25 13.32 2011 6 6
4 909.72 25 13.64 1451 6 8
5 195.12 25 14.40 555 6 10
6 0.12 25 14.75 293 6 11
7 -0.00 251 14.25 277 6 57

Cycle 6 GMT 1/ 1/2013 22: 4: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.36 32 14.55 423 6 6
2 2006.20 62 12.72 2830 6 6
3 1566.88 25 13.16 2282 6 6
4 881.00 25 13.64 1437 6 8
5 175.64 25 14.45 524 6 10
6 0.12 25 14.78 289 6 13
7 -0.00 251 14.23 280 6 58

Cycle 5 GMT 22/12/2012 22:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.36 29 14.61 423 6 6
2 1078.36 3 14.55 1711 6 6
3 2003.44 62 12.70 2833 6 6
4 1557.60 25 13.17 2270 6 6
5 863.80 25 13.64 1414 6 8
6 162.48 25 14.43 519 6 10
7 0.52 250 14.24 287 6 47

Cycle 4 GMT 12/12/2012 22:30:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.88 29 14.55 423 6 6
2 1036.40 1 14.61 1673 6 6
3 1504.24 62 13.03 2188 6 6
4 1301.80 25 13.32 1942 6 6
5 602.44 25 13.91 1083 6 9
6 25.64 25 14.67 328 6 11
7 0.08 25 14.62 295 6 15
8 0.04 251 14.15 279 6 115

Cycle 3 GMT 11/12/2012 22:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.84 34 14.42 423 6 6
2 892.36 -3 14.42 423 6 6
3 1511.12 62 12.97 2192 6 6
4 1299.92 25 13.28 1928 6 6
5 612.88 25 13.85 1086 6 8
6 62.84 25 14.56 378 6 11
7 0.12 251 14.17 283 6 47

Cycle 2 GMT 10/12/2012 21:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 28 14.48 423 6 6
2 1316.92 7 13.78 2019 6 6
3 1314.52 7 13.91 1961 6 6
4 1515.00 62 12.88 2183 6 6
5 1300.68 25 13.16 1972 6 6
6 615.48 25 13.75 1101 6 9
7 29.04 25 14.58 334 6 11
8 0.12 25 14.58 289 6 13
9 0.12 251 14.09 280 6 99

Cycle 1 GMT 10/12/2012 0: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.92 27 14.55 384 6 6
2 1136.28 3 14.04 1788 6 6
3 1264.64 62 12.86 1906 6 6
4 319.00 25 14.05 728 6 9
5 0.24 25 14.60 291 6 11
6 0.08 251 14.09 275 6 48

Cycle 0 GMT 9/12/2012 14:18: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.76 62 14.17 403 6
2 89.20 25 14.44 376 6 6
3 41.36 25 14.50 314 6 8
4 0.32 25 14.61 261 6 9
5 0.28 250 14.22 247 6