SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.64 | 41 | 10.73 | 423 | 6 | 6 |
2 | 1037.16 | 2 | 8.62 | 1653 | 6 | 6 |
3 | 1027.88 | 1 | 8.43 | 1653 | 6 | 6 |
4 | 1983.12 | 60 | 5.89 | 3103 | 6 | 6 |
5 | 1945.72 | 30 | 6.13 | 2908 | 6 | 6 |
6 | 1869.04 | 30 | 6.45 | 2775 | 6 | 6 |
7 | 1777.12 | 30 | 6.56 | 2650 | 6 | 6 |
8 | 1667.88 | 30 | 6.74 | 2478 | 6 | 6 |
9 | 1435.12 | 30 | 7.19 | 2209 | 5 | 6 |
10 | 1332.32 | 30 | 7.45 | 2065 | 6 | 6 |
11 | 816.84 | 30 | 8.60 | 1409 | 6 | 6 |
12 | 292.52 | 30 | 9.85 | 733 | 6 | 6 |
13 | 78.96 | 30 | 10.47 | 426 | 6 | 6 |
14 | 19.12 | 30 | 10.69 | 331 | 6 | 6 |
15 | -0.04 | 180 | 10.78 | 295 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.84 | 42 | 10.79 | 423 | 6 | 6 |
2 | 981.12 | -1 | 0.00 | 0 | 6 | 6 |
3 | 1234.84 | 60 | 7.92 | 1952 | 6 | 6 |
4 | 1234.12 | 30 | 8.02 | 1961 | 6 | 6 |
5 | 1160.00 | 30 | 8.26 | 1847 | 6 | 6 |
6 | 1044.88 | 30 | 8.38 | 1714 | 6 | 6 |
7 | 663.72 | 30 | 9.20 | 1223 | 6 | 6 |
8 | 81.80 | 30 | 10.59 | 419 | 6 | 6 |
9 | 44.36 | 30 | 10.65 | 369 | 6 | 6 |
10 | -0.00 | 180 | 10.86 | 292 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.72 | 42 | 10.86 | 423 | 6 | 6 |
2 | 2001.28 | 61 | 6.73 | 2996 | 6 | 6 |
3 | 1925.60 | 31 | 6.99 | 2840 | 6 | 6 |
4 | 1832.64 | 30 | 7.15 | 2738 | 6 | 6 |
5 | 1720.44 | 30 | 7.38 | 2586 | 6 | 6 |
6 | 1356.64 | 31 | 7.98 | 2132 | 6 | 6 |
7 | 1002.00 | 31 | 8.66 | 1669 | 6 | 6 |
8 | 500.56 | 30 | 9.70 | 1001 | 6 | 6 |
9 | 111.68 | 30 | 10.54 | 478 | 6 | 6 |
10 | 57.44 | 30 | 10.69 | 390 | 6 | 6 |
11 | -0.04 | 180 | 10.86 | 296 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.24 | 42 | 10.79 | 423 | 6 | 6 |
2 | 982.52 | -1 | 10.79 | 423 | 6 | 6 |
3 | 1029.60 | 1 | 8.81 | 1750 | 6 | 6 |
4 | 2005.52 | 60 | 7.12 | 2956 | 6 | 6 |
5 | 1926.84 | 30 | 7.27 | 2860 | 6 | 6 |
6 | 1839.76 | 30 | 7.48 | 2743 | 5 | 6 |
7 | 1740.40 | 30 | 7.76 | 2586 | 6 | 6 |
8 | 1363.16 | 30 | 8.10 | 2164 | 6 | 6 |
9 | 1111.72 | 30 | 8.66 | 1823 | 6 | 6 |
10 | 561.08 | 30 | 9.68 | 1090 | 6 | 6 |
11 | 79.24 | 30 | 10.67 | 424 | 6 | 6 |
12 | 22.44 | 30 | 10.84 | 331 | 6 | 6 |
13 | -0.04 | 180 | 10.92 | 293 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.76 | 43 | 10.98 | 384 | 6 | 6 |
2 | 974.96 | -1 | 10.98 | 384 | 6 | 6 |
3 | 1027.40 | 1 | 9.07 | 1750 | 6 | 6 |
4 | 2001.76 | 60 | 7.32 | 2979 | 6 | 6 |
5 | 1905.32 | 30 | 7.62 | 2815 | 6 | 6 |
6 | 1675.48 | 30 | 8.07 | 2538 | 6 | 6 |
7 | 1581.20 | 30 | 8.16 | 2385 | 5 | 6 |
8 | 1479.00 | 30 | 8.20 | 2304 | 6 | 6 |
9 | 786.28 | 30 | 9.38 | 1396 | 6 | 6 |
10 | 215.76 | 30 | 10.43 | 629 | 6 | 6 |
11 | 47.92 | 30 | 10.79 | 377 | 6 | 6 |
12 | 32.68 | 30 | 10.84 | 352 | 6 | 7 |
13 | -0.00 | 180 | 10.93 | 297 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.12 | 42 | 10.92 | 403 | 6 | 6 |
2 | 1033.28 | 1 | 9.07 | 1769 | 6 | 6 |
3 | 2010.28 | 60 | 7.41 | 3019 | 6 | 6 |
4 | 1959.32 | 30 | 7.76 | 2897 | 6 | 6 |
5 | 1841.24 | 30 | 7.78 | 2799 | 6 | 6 |
6 | 1614.60 | 30 | 8.24 | 2470 | 6 | 6 |
7 | 1112.96 | 30 | 8.89 | 1850 | 6 | 6 |
8 | 600.08 | 30 | 9.80 | 1153 | 6 | 6 |
9 | 111.20 | 30 | 10.71 | 468 | 6 | 6 |
10 | 33.80 | 30 | 10.86 | 353 | 6 | 6 |
11 | 0.04 | 180 | 10.96 | 296 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.60 | 42 | 10.92 | 423 | 6 | 6 |
2 | 2002.92 | 60 | 7.66 | 2982 | 6 | 6 |
3 | 1931.04 | 30 | 7.85 | 2855 | 6 | 6 |
4 | 1841.64 | 30 | 7.94 | 2799 | 6 | 6 |
5 | 1723.64 | 30 | 8.21 | 2614 | 6 | 6 |
6 | 1212.64 | 30 | 8.88 | 1972 | 6 | 6 |
7 | 831.60 | 30 | 9.53 | 1459 | 6 | 6 |
8 | 139.60 | 30 | 10.66 | 515 | 6 | 6 |
9 | 40.24 | 30 | 10.88 | 365 | 6 | 6 |
10 | -0.04 | 180 | 10.98 | 295 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.68 | 41 | 10.98 | 403 | 6 | 6 |
2 | 1006.64 | 2 | 9.45 | 1711 | 6 | 6 |
3 | 969.64 | -1 | 9.45 | 1711 | 6 | 6 |
4 | 2001.80 | 60 | 7.82 | 3001 | 6 | 6 |
5 | 1922.12 | 30 | 8.09 | 2863 | 6 | 6 |
6 | 1820.08 | 30 | 8.24 | 2744 | 6 | 6 |
7 | 1277.92 | 30 | 8.98 | 2050 | 6 | 6 |
8 | 1174.80 | 30 | 9.11 | 1909 | 6 | 6 |
9 | 342.52 | 30 | 10.36 | 808 | 6 | 6 |
10 | 94.16 | 30 | 10.78 | 454 | 6 | 6 |
11 | 22.36 | 30 | 10.91 | 345 | 6 | 7 |
12 | 10.72 | 30 | 10.95 | 323 | 6 | 7 |
13 | -0.16 | 180 | 10.97 | 305 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.68 | 42 | 10.98 | 423 | 6 | 6 |
2 | 977.68 | -1 | 10.98 | 423 | 6 | 6 |
3 | 2001.64 | 60 | 7.95 | 2984 | 6 | 6 |
4 | 1919.36 | 30 | 8.21 | 2885 | 6 | 6 |
5 | 1807.28 | 30 | 8.33 | 2757 | 5 | 6 |
6 | 1239.92 | 30 | 9.05 | 2020 | 6 | 6 |
7 | 1120.64 | 30 | 9.27 | 1848 | 6 | 6 |
8 | 271.64 | 30 | 10.51 | 707 | 6 | 6 |
9 | 43.04 | 30 | 10.92 | 376 | 6 | 6 |
10 | 35.40 | 30 | 10.92 | 360 | 6 | 7 |
11 | -0.08 | 180 | 11.00 | 299 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.12 | 42 | 10.92 | 442 | 6 | 6 |
2 | 2004.12 | 60 | 8.09 | 2988 | 6 | 6 |
3 | 1913.12 | 30 | 8.22 | 2890 | 5 | 6 |
4 | 1671.00 | 30 | 8.69 | 2542 | 6 | 6 |
5 | 1313.08 | 30 | 9.12 | 2076 | 6 | 6 |
6 | 918.68 | 30 | 9.61 | 1574 | 6 | 6 |
7 | 236.76 | 30 | 10.59 | 656 | 6 | 6 |
8 | 35.68 | 30 | 10.95 | 363 | 6 | 6 |
9 | 19.96 | 30 | 10.94 | 344 | 6 | 7 |
10 | -0.04 | 180 | 11.01 | 300 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.28 | 42 | 10.98 | 403 | 6 | 6 |
2 | 2005.72 | 60 | 8.17 | 2995 | 6 | 6 |
3 | 1919.20 | 30 | 8.53 | 2839 | 5 | 6 |
4 | 1683.08 | 30 | 8.73 | 2566 | 6 | 6 |
5 | 1442.92 | 30 | 9.08 | 2259 | 5 | 6 |
6 | 770.08 | 30 | 9.89 | 1384 | 6 | 6 |
7 | 226.80 | 30 | 10.61 | 648 | 6 | 6 |
8 | 56.92 | 30 | 10.92 | 391 | 6 | 6 |
9 | 15.56 | 30 | 10.96 | 339 | 6 | 7 |
10 | -0.00 | 181 | 11.02 | 298 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.64 | 42 | 11.05 | 403 | 6 | 6 |
2 | 2007.04 | 60 | 8.26 | 3032 | 6 | 6 |
3 | 1923.32 | 30 | 8.50 | 2909 | 6 | 6 |
4 | 1821.64 | 30 | 8.66 | 2776 | 5 | 6 |
5 | 1187.16 | 30 | 9.46 | 1922 | 6 | 6 |
6 | 800.36 | 30 | 9.93 | 1411 | 6 | 6 |
7 | 133.36 | 30 | 10.77 | 515 | 6 | 6 |
8 | 39.04 | 30 | 10.95 | 366 | 6 | 6 |
9 | 22.24 | 30 | 10.99 | 335 | 6 | 7 |
10 | -0.04 | 180 | 11.03 | 299 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.48 | 42 | 10.98 | 442 | 6 | 6 |
2 | 2005.76 | 60 | 8.43 | 2982 | 6 | 6 |
3 | 1926.20 | 30 | 8.61 | 2884 | 6 | 6 |
4 | 1829.08 | 30 | 8.85 | 2760 | 6 | 6 |
5 | 1416.20 | 30 | 9.27 | 2235 | 6 | 6 |
6 | 755.56 | 30 | 10.00 | 1369 | 6 | 6 |
7 | 223.24 | 30 | 10.68 | 640 | 6 | 6 |
8 | 43.16 | 30 | 10.94 | 372 | 6 | 6 |
9 | 26.84 | 30 | 10.99 | 344 | 6 | 7 |
10 | -0.08 | 180 | 11.04 | 300 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.72 | 42 | 11.05 | 423 | 6 | 6 |
2 | 2010.00 | 60 | 8.47 | 2995 | 6 | 6 |
3 | 1917.24 | 30 | 8.68 | 2892 | 6 | 6 |
4 | 1804.12 | 30 | 8.89 | 2712 | 6 | 6 |
5 | 1155.16 | 30 | 9.58 | 1893 | 6 | 6 |
6 | 778.92 | 30 | 10.05 | 1387 | 6 | 6 |
7 | 112.40 | 30 | 10.86 | 480 | 6 | 6 |
8 | 42.44 | 30 | 11.00 | 357 | 6 | 6 |
9 | 21.56 | 30 | 11.02 | 334 | 6 | 7 |
10 | -0.08 | 180 | 11.07 | 295 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 40 | 11.05 | 423 | 6 | 6 |
2 | 1042.52 | 1 | 9.96 | 1692 | 6 | 6 |
3 | 2000.28 | 60 | 8.58 | 2984 | 6 | 6 |
4 | 1904.40 | 30 | 8.88 | 2845 | 6 | 6 |
5 | 1675.24 | 30 | 9.10 | 2547 | 5 | 6 |
6 | 1558.00 | 30 | 9.20 | 2405 | 6 | 6 |
7 | 714.92 | 30 | 10.16 | 1303 | 6 | 6 |
8 | 92.88 | 30 | 10.89 | 454 | 6 | 6 |
9 | 30.32 | 30 | 11.01 | 352 | 6 | 6 |
10 | 17.00 | 30 | 11.02 | 329 | 6 | 7 |
11 | -0.16 | 181 | 11.06 | 298 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.08 | 41 | 11.05 | 403 | 6 | 6 |
2 | 966.52 | -1 | 11.05 | 403 | 6 | 6 |
3 | 2003.24 | 60 | 8.64 | 3001 | 6 | 6 |
4 | 1891.12 | 30 | 8.79 | 2877 | 6 | 6 |
5 | 1659.08 | 31 | 9.18 | 2531 | 6 | 6 |
6 | 1144.12 | 31 | 9.68 | 1900 | 6 | 6 |
7 | 602.72 | 31 | 10.30 | 1161 | 6 | 6 |
8 | 95.20 | 31 | 10.92 | 448 | 6 | 6 |
9 | 34.60 | 31 | 11.00 | 360 | 6 | 6 |
10 | -0.00 | 180 | 11.07 | 296 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 41 | 11.05 | 423 | 6 | 6 |
2 | 1021.44 | 1 | 9.90 | 1769 | 6 | 6 |
3 | 2007.12 | 62 | 8.72 | 2981 | 6 | 6 |
4 | 1841.24 | 25 | 8.96 | 2805 | 6 | 6 |
5 | 1653.56 | 25 | 9.24 | 2522 | 6 | 6 |
6 | 1437.32 | 25 | 9.53 | 2230 | 6 | 6 |
7 | 965.96 | 25 | 9.94 | 1639 | 6 | 6 |
8 | 491.32 | 25 | 10.45 | 1005 | 6 | 6 |
9 | 116.68 | 25 | 10.87 | 499 | 6 | 6 |
10 | 56.64 | 25 | 10.98 | 393 | 6 | 6 |
11 | 26.16 | 25 | 11.01 | 349 | 6 | 7 |
12 | -0.12 | 251 | 11.07 | 298 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.64 | 41 | 11.05 | 403 | 6 | 6 |
2 | 2004.20 | 62 | 8.78 | 2976 | 6 | 6 |
3 | 1857.28 | 25 | 9.11 | 2780 | 6 | 6 |
4 | 1678.88 | 25 | 9.24 | 2580 | 6 | 6 |
5 | 1057.76 | 25 | 9.84 | 1774 | 6 | 6 |
6 | 843.12 | 25 | 10.07 | 1499 | 6 | 6 |
7 | 194.04 | 25 | 10.78 | 611 | 6 | 6 |
8 | 88.96 | 25 | 10.91 | 457 | 6 | 6 |
9 | 48.08 | 25 | 11.02 | 376 | 6 | 6 |
10 | -0.04 | 251 | 11.08 | 297 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 41 | 11.05 | 423 | 6 | 6 |
2 | 1855.52 | 62 | 8.91 | 2808 | 6 | 6 |
3 | 1710.64 | 25 | 9.20 | 2617 | 6 | 6 |
4 | 1502.40 | 24 | 9.43 | 2349 | 5 | 6 |
5 | 1296.16 | 24 | 9.67 | 2072 | 6 | 6 |
6 | 1076.80 | 24 | 9.85 | 1809 | 6 | 6 |
7 | 387.72 | 24 | 10.59 | 872 | 6 | 6 |
8 | 83.24 | 24 | 10.97 | 436 | 6 | 6 |
9 | 49.28 | 24 | 11.02 | 372 | 6 | 6 |
10 | 22.84 | 24 | 11.06 | 332 | 6 | 7 |
11 | -0.08 | 250 | 11.09 | 294 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 40 | 11.05 | 423 | 6 | 6 |
2 | 2010.32 | 62 | 8.84 | 3007 | 6 | 6 |
3 | 1884.80 | 25 | 9.15 | 2836 | 6 | 6 |
4 | 1697.36 | 25 | 9.31 | 2584 | 5 | 6 |
5 | 1221.76 | 25 | 9.74 | 1984 | 6 | 6 |
6 | 787.56 | 25 | 10.18 | 1416 | 6 | 6 |
7 | 336.12 | 25 | 10.64 | 810 | 6 | 6 |
8 | 82.08 | 25 | 10.95 | 443 | 6 | 6 |
9 | 46.96 | 25 | 11.02 | 374 | 6 | 6 |
10 | -0.00 | 251 | 11.09 | 292 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.80 | 40 | 11.11 | 423 | 6 | 6 |
2 | 2006.00 | 62 | 8.88 | 2991 | 6 | 6 |
3 | 1854.48 | 25 | 9.22 | 2816 | 6 | 6 |
4 | 1668.32 | 25 | 9.42 | 2570 | 5 | 6 |
5 | 1253.12 | 25 | 9.75 | 2039 | 6 | 6 |
6 | 813.92 | 25 | 10.16 | 1461 | 6 | 6 |
7 | 186.28 | 25 | 10.81 | 603 | 6 | 6 |
8 | 94.32 | 25 | 10.97 | 449 | 6 | 6 |
9 | 52.96 | 25 | 11.02 | 387 | 6 | 6 |
10 | -0.04 | 250 | 11.09 | 295 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.64 | 41 | 11.05 | 423 | 6 | 6 |
2 | 981.88 | -1 | 11.05 | 423 | 6 | 6 |
3 | 2005.12 | 62 | 8.89 | 2996 | 6 | 6 |
4 | 1812.52 | 25 | 9.23 | 2757 | 6 | 6 |
5 | 1436.64 | 25 | 9.61 | 2264 | 6 | 6 |
6 | 1238.76 | 25 | 9.74 | 2028 | 6 | 6 |
7 | 824.40 | 25 | 10.20 | 1465 | 6 | 6 |
8 | 188.08 | 25 | 10.84 | 601 | 6 | 6 |
9 | 89.32 | 25 | 10.93 | 447 | 6 | 6 |
10 | 49.52 | 25 | 11.03 | 380 | 6 | 6 |
11 | 27.08 | 25 | 11.05 | 339 | 6 | 7 |
12 | -0.00 | 251 | 11.09 | 295 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.08 | 41 | 11.05 | 403 | 6 | 6 |
2 | 1957.16 | 62 | 8.86 | 2956 | 6 | 6 |
3 | 1772.48 | 25 | 9.19 | 2730 | 6 | 6 |
4 | 1580.16 | 25 | 9.44 | 2455 | 6 | 6 |
5 | 1181.28 | 25 | 9.81 | 1957 | 6 | 6 |
6 | 758.08 | 25 | 10.26 | 1380 | 6 | 6 |
7 | 309.72 | 25 | 10.69 | 765 | 6 | 6 |
8 | 64.20 | 25 | 10.99 | 407 | 6 | 6 |
9 | 39.12 | 25 | 11.03 | 365 | 6 | 6 |
10 | -0.00 | 251 | 11.07 | 300 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 41 | 11.05 | 423 | 6 | 6 |
2 | 1988.96 | 62 | 8.87 | 2990 | 6 | 6 |
3 | 1821.52 | 24 | 9.20 | 2788 | 5 | 6 |
4 | 1624.36 | 24 | 9.42 | 2511 | 6 | 6 |
5 | 1196.64 | 24 | 9.80 | 1964 | 6 | 6 |
6 | 981.68 | 24 | 10.00 | 1689 | 6 | 6 |
7 | 315.92 | 24 | 10.68 | 780 | 6 | 6 |
8 | 70.52 | 24 | 10.94 | 438 | 6 | 6 |
9 | 35.36 | 24 | 11.02 | 368 | 6 | 6 |
10 | 20.04 | 24 | 11.05 | 338 | 6 | 7 |
11 | -0.00 | 251 | 11.07 | 301 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.56 | 42 | 11.05 | 403 | 6 | 6 |
2 | 969.92 | -1 | 11.05 | 403 | 6 | 6 |
3 | 2003.00 | 62 | 8.87 | 2993 | 6 | 6 |
4 | 1849.48 | 25 | 9.15 | 2799 | 6 | 6 |
5 | 1453.32 | 25 | 9.56 | 2301 | 5 | 6 |
6 | 1250.00 | 25 | 9.68 | 2063 | 6 | 6 |
7 | 811.52 | 25 | 10.19 | 1445 | 6 | 6 |
8 | 358.48 | 25 | 10.63 | 841 | 6 | 6 |
9 | 63.92 | 25 | 10.98 | 412 | 6 | 6 |
10 | 34.00 | 25 | 11.02 | 365 | 6 | 6 |
11 | 17.40 | 25 | 11.04 | 334 | 6 | 7 |
12 | -0.20 | 251 | 11.06 | 300 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.16 | 42 | 10.98 | 442 | 6 | 6 |
2 | 967.12 | -1 | 10.98 | 442 | 6 | 6 |
3 | 1026.40 | 1 | 10.09 | 1711 | 6 | 6 |
4 | 2003.60 | 62 | 8.85 | 2977 | 6 | 6 |
5 | 1855.40 | 25 | 9.07 | 2822 | 6 | 6 |
6 | 1668.32 | 25 | 9.29 | 2576 | 6 | 6 |
7 | 1464.20 | 25 | 9.54 | 2288 | 6 | 6 |
8 | 1003.12 | 25 | 9.93 | 1720 | 6 | 6 |
9 | 307.16 | 25 | 10.66 | 765 | 6 | 6 |
10 | 69.20 | 25 | 10.98 | 409 | 6 | 6 |
11 | 38.72 | 25 | 11.02 | 366 | 6 | 6 |
12 | 18.72 | 25 | 11.03 | 334 | 6 | 6 |
13 | -0.04 | 250 | 11.06 | 296 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.36 | 36 | 11.05 | 403 | 6 | 6 |
2 | 1026.68 | 2 | 10.15 | 1692 | 6 | 6 |
3 | 1061.60 | 2 | 10.09 | 1730 | 6 | 6 |
4 | 1080.76 | 2 | 9.90 | 1807 | 6 | 6 |
5 | 1030.80 | 1 | 10.15 | 1711 | 6 | 6 |
6 | 2003.40 | 62 | 8.85 | 2997 | 6 | 6 |
7 | 1823.80 | 25 | 9.16 | 2765 | 5 | 6 |
8 | 1629.12 | 24 | 9.38 | 2484 | 6 | 6 |
9 | 1424.96 | 24 | 9.55 | 2247 | 6 | 6 |
10 | 977.00 | 24 | 9.96 | 1672 | 6 | 6 |
11 | 518.36 | 24 | 10.43 | 1057 | 6 | 6 |
12 | 120.20 | 24 | 10.88 | 495 | 6 | 6 |
13 | 34.00 | 24 | 11.01 | 363 | 6 | 6 |
14 | 20.20 | 24 | 11.04 | 337 | 6 | 7 |
15 | -0.00 | 250 | 11.06 | 297 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.24 | 34 | 12.19 | 423 | 6 | 6 |
2 | 1061.48 | 2 | 12.06 | 1788 | 6 | 6 |
3 | 2007.28 | 62 | 9.39 | 2995 | 6 | 6 |
4 | 1849.72 | 25 | 9.21 | 2749 | 6 | 6 |
5 | 1634.64 | 25 | 9.36 | 2517 | 6 | 6 |
6 | 1209.52 | 25 | 9.78 | 1974 | 6 | 6 |
7 | 770.56 | 25 | 10.22 | 1391 | 6 | 6 |
8 | 295.44 | 25 | 10.70 | 745 | 6 | 6 |
9 | 59.04 | 25 | 10.96 | 397 | 6 | 6 |
10 | 28.20 | 25 | 11.00 | 357 | 6 | 6 |
11 | 12.96 | 25 | 11.01 | 330 | 6 | 7 |
12 | -0.04 | 251 | 11.02 | 303 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.20 | 32 | 12.89 | 461 | 6 | 6 |
2 | 1037.12 | 1 | 12.19 | 1788 | 6 | 6 |
3 | 1020.32 | 1 | 11.43 | 1807 | 6 | 6 |
4 | 2002.32 | 62 | 8.70 | 2974 | 6 | 6 |
5 | 1832.24 | 25 | 9.63 | 2793 | 6 | 6 |
6 | 1631.08 | 25 | 9.74 | 2515 | 6 | 6 |
7 | 1197.28 | 25 | 10.23 | 1963 | 6 | 6 |
8 | 767.12 | 25 | 10.73 | 1414 | 6 | 6 |
9 | 309.92 | 25 | 11.46 | 784 | 6 | 6 |
10 | 60.56 | 25 | 11.97 | 413 | 6 | 6 |
11 | 30.52 | 25 | 11.93 | 372 | 6 | 7 |
12 | 17.60 | 25 | 11.88 | 343 | 6 | 8 |
13 | -0.04 | 251 | 11.79 | 310 | 6 | 46 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.88 | 31 | 13.78 | 480 | 6 | 6 |
2 | 1002.80 | 2 | 12.76 | 1711 | 6 | 6 |
3 | 960.24 | -1 | 12.76 | 1711 | 6 | 6 |
4 | 1995.00 | 62 | 7.94 | 3003 | 6 | 6 |
5 | 1853.84 | 25 | 9.73 | 2812 | 6 | 6 |
6 | 1681.20 | 25 | 9.84 | 2613 | 6 | 6 |
7 | 1258.92 | 25 | 10.63 | 2047 | 6 | 6 |
8 | 1054.92 | 25 | 10.77 | 1789 | 5 | 6 |
9 | 179.24 | 25 | 12.44 | 605 | 6 | 6 |
10 | 85.68 | 25 | 12.55 | 464 | 6 | 7 |
11 | 43.08 | 25 | 12.56 | 397 | 6 | 8 |
12 | 0.88 | 251 | 12.27 | 319 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.32 | 31 | 14.04 | 461 | 6 | 6 |
2 | 2012.44 | 62 | 7.71 | 3011 | 6 | 6 |
3 | 1868.96 | 25 | 9.79 | 2859 | 5 | 6 |
4 | 1701.24 | 25 | 10.22 | 2641 | 6 | 6 |
5 | 1493.68 | 25 | 10.57 | 2388 | 6 | 6 |
6 | 1028.48 | 25 | 11.58 | 1757 | 6 | 6 |
7 | 355.68 | 25 | 13.11 | 882 | 6 | 7 |
8 | 66.40 | 25 | 13.86 | 451 | 6 | 8 |
9 | 19.76 | 25 | 14.00 | 378 | 6 | 8 |
10 | -0.08 | 251 | 13.23 | 328 | 6 | 66 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.00 | 32 | 14.17 | 461 | 6 | 6 |
2 | 966.92 | -1 | 14.17 | 461 | 6 | 6 |
3 | 2008.84 | 62 | 7.83 | 3005 | 6 | 6 |
4 | 1844.72 | 25 | 10.31 | 2770 | 6 | 6 |
5 | 1644.60 | 25 | 10.85 | 2580 | 5 | 6 |
6 | 1253.64 | 25 | 12.00 | 2082 | 6 | 6 |
7 | 592.32 | 25 | 13.06 | 1201 | 6 | 6 |
8 | 157.56 | 25 | 13.77 | 591 | 6 | 7 |
9 | 39.60 | 25 | 14.08 | 403 | 6 | 8 |
10 | 18.96 | 25 | 14.12 | 370 | 6 | 9 |
11 | -0.16 | 244 | 13.50 | 320 | 6 | 185 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 32 | 14.23 | 461 | 6 | 6 |
2 | 2004.04 | 62 | 8.05 | 2961 | 6 | 6 |
3 | 1837.00 | 25 | 10.62 | 2803 | 6 | 6 |
4 | 1625.76 | 25 | 11.20 | 2584 | 6 | 6 |
5 | 1406.28 | 25 | 11.80 | 2274 | 5 | 6 |
6 | 666.40 | 25 | 13.09 | 1297 | 6 | 7 |
7 | 108.92 | 25 | 14.01 | 513 | 6 | 7 |
8 | 51.60 | 25 | 14.20 | 420 | 6 | 8 |
9 | 23.96 | 25 | 14.26 | 378 | 6 | 9 |
10 | -0.04 | 239 | 13.80 | 318 | 6 | 225 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.88 | 32 | 14.23 | 461 | 6 | 6 |
2 | 1992.52 | 62 | 8.03 | 2959 | 6 | 6 |
3 | 1855.56 | 25 | 10.65 | 2872 | 6 | 6 |
4 | 1668.88 | 25 | 11.48 | 2566 | 5 | 6 |
5 | 1216.04 | 25 | 12.27 | 2047 | 6 | 6 |
6 | 556.16 | 25 | 13.26 | 1161 | 6 | 6 |
7 | 143.72 | 25 | 13.96 | 564 | 6 | 8 |
8 | 65.48 | 25 | 14.13 | 453 | 6 | 9 |
9 | -0.00 | 251 | 13.83 | 322 | 6 | 77 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.12 | 32 | 14.23 | 461 | 6 | 6 |
2 | 980.72 | -1 | 14.23 | 461 | 6 | 6 |
3 | 1027.68 | 1 | 11.81 | 1750 | 6 | 6 |
4 | 2002.48 | 62 | 7.98 | 2999 | 6 | 6 |
5 | 1855.92 | 25 | 10.98 | 2841 | 5 | 6 |
6 | 1669.00 | 25 | 11.69 | 2576 | 6 | 6 |
7 | 1217.32 | 25 | 12.40 | 2032 | 6 | 7 |
8 | 534.60 | 25 | 13.38 | 1128 | 6 | 6 |
9 | 124.88 | 25 | 13.99 | 538 | 6 | 7 |
10 | 32.52 | 25 | 14.19 | 395 | 6 | 8 |
11 | -0.00 | 251 | 13.93 | 324 | 6 | 86 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.24 | 31 | 14.17 | 461 | 6 | 6 |
2 | 1036.84 | 1 | 11.94 | 1788 | 6 | 6 |
3 | 1883.56 | 62 | 7.90 | 2839 | 6 | 6 |
4 | 1883.56 | 25 | 10.96 | 2864 | 6 | 6 |
5 | 1883.44 | 25 | 11.25 | 2910 | 6 | 6 |
6 | 1883.32 | 25 | 11.46 | 2878 | 6 | 6 |
7 | 1696.44 | 25 | 11.77 | 2634 | 6 | 6 |
8 | 174.20 | 25 | 13.90 | 611 | 6 | 7 |
9 | 85.36 | 25 | 14.09 | 480 | 6 | 8 |
10 | -0.00 | 250 | 14.01 | 324 | 6 | 52 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.68 | 31 | 14.29 | 442 | 6 | 6 |
2 | 979.96 | -1 | 14.29 | 442 | 6 | 6 |
3 | 1369.00 | 62 | 8.92 | 2145 | 6 | 6 |
4 | 1291.00 | 25 | 11.75 | 2110 | 6 | 6 |
5 | 1094.40 | 25 | 12.36 | 1872 | 6 | 6 |
6 | 627.52 | 25 | 13.20 | 1249 | 6 | 7 |
7 | 153.68 | 25 | 13.94 | 580 | 6 | 7 |
8 | 45.64 | 25 | 14.19 | 409 | 6 | 8 |
9 | 24.64 | 25 | 14.22 | 380 | 6 | 9 |
10 | 0.08 | 231 | 14.10 | 327 | 6 | 175 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.64 | 31 | 14.23 | 461 | 6 | 6 |
2 | 1595.56 | 62 | 8.30 | 2445 | 6 | 6 |
3 | 1497.20 | 25 | 11.50 | 2382 | 6 | 6 |
4 | 1308.24 | 25 | 12.06 | 2137 | 6 | 6 |
5 | 897.12 | 25 | 12.80 | 1632 | 6 | 6 |
6 | 210.80 | 25 | 13.87 | 662 | 6 | 7 |
7 | 50.96 | 25 | 14.18 | 411 | 6 | 8 |
8 | 27.32 | 25 | 14.24 | 376 | 6 | 9 |
9 | -0.00 | 242 | 14.08 | 324 | 6 | 187 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.72 | 31 | 14.36 | 423 | 6 | 6 |
2 | 2006.44 | 62 | 7.34 | 3027 | 6 | 6 |
3 | 1880.88 | 25 | 11.16 | 2866 | 6 | 6 |
4 | 1699.64 | 25 | 11.71 | 2632 | 6 | 6 |
5 | 1270.32 | 25 | 12.43 | 2087 | 5 | 6 |
6 | 815.96 | 25 | 13.04 | 1503 | 6 | 7 |
7 | 154.72 | 25 | 13.97 | 581 | 6 | 7 |
8 | 72.92 | 25 | 14.10 | 457 | 6 | 8 |
9 | 1.12 | 25 | 14.30 | 332 | 6 | 10 |
10 | -0.08 | 233 | 14.10 | 321 | 6 | 156 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.12 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2006.72 | 62 | 7.15 | 2986 | 6 | 6 |
3 | 1897.92 | 25 | 11.16 | 2909 | 6 | 6 |
4 | 1735.88 | 25 | 11.68 | 2668 | 6 | 6 |
5 | 1296.72 | 25 | 12.42 | 2124 | 6 | 6 |
6 | 624.20 | 25 | 13.31 | 1241 | 6 | 7 |
7 | 159.60 | 25 | 13.93 | 586 | 6 | 8 |
8 | 44.80 | 25 | 14.14 | 405 | 6 | 8 |
9 | 7.72 | 25 | 14.25 | 339 | 6 | 9 |
10 | 0.04 | 233 | 14.18 | 321 | 6 | 224 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.36 | 32 | 14.23 | 461 | 6 | 6 |
2 | 979.04 | -1 | 14.23 | 461 | 6 | 6 |
3 | 1022.88 | 1 | 11.62 | 1750 | 6 | 6 |
4 | 2005.08 | 62 | 6.89 | 3013 | 6 | 6 |
5 | 1882.72 | 25 | 11.25 | 2901 | 6 | 6 |
6 | 1672.84 | 25 | 11.80 | 2613 | 6 | 6 |
7 | 1469.04 | 25 | 12.19 | 2347 | 6 | 6 |
8 | 771.40 | 25 | 13.16 | 1434 | 6 | 6 |
9 | 136.28 | 25 | 14.01 | 547 | 6 | 7 |
10 | 62.36 | 25 | 14.12 | 432 | 6 | 8 |
11 | 29.20 | 25 | 14.16 | 378 | 6 | 10 |
12 | 0.04 | 234 | 14.16 | 323 | 6 | 164 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.16 | 32 | 14.23 | 442 | 6 | 6 |
2 | 1486.56 | 62 | 8.21 | 2300 | 6 | 6 |
3 | 1386.76 | 24 | 11.79 | 2247 | 6 | 6 |
4 | 1207.36 | 24 | 12.36 | 2016 | 6 | 6 |
5 | 789.76 | 24 | 13.10 | 1467 | 6 | 6 |
6 | 331.48 | 25 | 13.68 | 845 | 6 | 7 |
7 | 57.80 | 24 | 14.09 | 438 | 6 | 8 |
8 | 28.08 | 24 | 14.14 | 382 | 6 | 9 |
9 | -0.04 | 242 | 14.14 | 326 | 6 | 173 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.52 | 32 | 14.23 | 442 | 6 | 6 |
2 | 950.56 | -1 | 14.23 | 442 | 6 | 6 |
3 | 1021.04 | 1 | 11.11 | 1750 | 6 | 6 |
4 | 1779.64 | 62 | 7.12 | 2685 | 6 | 6 |
5 | 1720.40 | 25 | 11.51 | 2695 | 6 | 6 |
6 | 1555.08 | 24 | 12.00 | 2470 | 5 | 6 |
7 | 1343.36 | 24 | 12.38 | 2199 | 6 | 6 |
8 | 445.56 | 24 | 13.57 | 997 | 6 | 7 |
9 | 106.32 | 24 | 14.02 | 509 | 6 | 7 |
10 | 50.88 | 24 | 14.12 | 418 | 6 | 8 |
11 | 0.08 | 251 | 14.20 | 328 | 6 | 98 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.32 | 31 | 14.29 | 442 | 6 | 6 |
2 | 1029.36 | 1 | 11.49 | 1750 | 6 | 6 |
3 | 1238.64 | 62 | 8.65 | 1972 | 6 | 6 |
4 | 1238.64 | 25 | 11.92 | 2057 | 6 | 6 |
5 | 1238.72 | 24 | 12.18 | 2070 | 6 | 6 |
6 | 1238.76 | 24 | 12.34 | 2062 | 6 | 7 |
7 | 1238.88 | 24 | 12.49 | 2051 | 6 | 7 |
8 | 1239.00 | 24 | 12.49 | 2076 | 6 | 8 |
9 | 1239.12 | 24 | 12.58 | 2059 | 6 | 9 |
10 | 1239.24 | 24 | 12.56 | 2063 | 6 | 10 |
11 | 1239.32 | 24 | 12.59 | 2070 | 6 | 11 |
12 | 1239.36 | 24 | 12.65 | 2049 | 6 | 14 |
13 | 1239.40 | 24 | 12.66 | 2049 | 6 | 16 |
14 | 1239.40 | 25 | 12.65 | 2062 | 6 | 17 |
15 | 1239.36 | 25 | 12.62 | 2082 | 6 | 20 |
16 | -0.28 | 152 | 14.09 | 339 | 6 | 200 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.60 | 32 | 14.29 | 423 | 6 | 6 |
2 | 975.92 | -1 | 14.29 | 423 | 6 | 6 |
3 | 1175.16 | 62 | 8.79 | 1876 | 6 | 6 |
4 | 1130.88 | 24 | 12.16 | 1913 | 6 | 6 |
5 | 963.72 | 24 | 12.69 | 1697 | 6 | 6 |
6 | 782.64 | 24 | 13.01 | 1470 | 6 | 7 |
7 | 130.24 | 24 | 13.97 | 539 | 6 | 7 |
8 | 67.16 | 24 | 14.08 | 438 | 6 | 8 |
9 | 32.16 | 24 | 14.13 | 380 | 6 | 9 |
10 | -0.00 | 234 | 14.23 | 318 | 6 | 168 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 32 | 14.17 | 461 | 6 | 6 |
2 | 1481.48 | 62 | 7.89 | 2269 | 6 | 6 |
3 | 1408.12 | 24 | 11.86 | 2265 | 6 | 6 |
4 | 1230.44 | 24 | 12.31 | 2061 | 6 | 6 |
5 | 1012.20 | 24 | 12.71 | 1774 | 6 | 6 |
6 | 286.60 | 24 | 13.75 | 778 | 6 | 7 |
7 | 63.60 | 24 | 14.03 | 443 | 6 | 7 |
8 | 37.64 | 24 | 14.15 | 387 | 6 | 8 |
9 | -0.00 | 247 | 14.21 | 322 | 6 | 215 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.96 | 32 | 14.17 | 461 | 6 | 6 |
2 | 1747.44 | 62 | 7.09 | 2676 | 6 | 6 |
3 | 1674.84 | 25 | 11.49 | 2614 | 6 | 6 |
4 | 1532.32 | 25 | 12.02 | 2405 | 6 | 6 |
5 | 1122.64 | 24 | 12.67 | 1922 | 6 | 6 |
6 | 683.32 | 24 | 13.26 | 1330 | 6 | 6 |
7 | 100.52 | 24 | 14.05 | 497 | 6 | 7 |
8 | 50.44 | 24 | 14.10 | 418 | 6 | 8 |
9 | 23.04 | 24 | 14.14 | 372 | 6 | 9 |
10 | -0.00 | 231 | 14.23 | 323 | 6 | 178 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.52 | 32 | 14.23 | 442 | 6 | 6 |
2 | 979.96 | -1 | 14.23 | 442 | 6 | 6 |
3 | 1026.72 | 1 | 11.24 | 1750 | 6 | 6 |
4 | 1510.00 | 62 | 7.68 | 2307 | 6 | 6 |
5 | 1469.56 | 24 | 11.87 | 2328 | 6 | 6 |
6 | 1311.76 | 25 | 12.30 | 2155 | 6 | 6 |
7 | 872.08 | 25 | 12.94 | 1593 | 6 | 6 |
8 | 212.96 | 24 | 13.85 | 668 | 6 | 7 |
9 | 97.16 | 24 | 14.02 | 486 | 6 | 7 |
10 | 52.80 | 24 | 14.08 | 414 | 6 | 8 |
11 | 0.04 | 247 | 14.23 | 320 | 6 | 243 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 32 | 14.29 | 442 | 6 | 6 |
2 | 1349.96 | 62 | 7.99 | 2098 | 6 | 6 |
3 | 1348.68 | 24 | 11.89 | 2172 | 6 | 6 |
4 | 1179.40 | 25 | 12.42 | 1966 | 6 | 6 |
5 | 765.92 | 24 | 13.11 | 1426 | 6 | 6 |
6 | 313.08 | 24 | 13.71 | 812 | 6 | 7 |
7 | 71.80 | 25 | 14.06 | 447 | 6 | 7 |
8 | 33.68 | 24 | 14.15 | 384 | 6 | 8 |
9 | -0.00 | 242 | 14.23 | 319 | 6 | 239 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.68 | 32 | 14.29 | 461 | 6 | 6 |
2 | 1494.68 | 62 | 7.27 | 2309 | 6 | 6 |
3 | 1474.48 | 24 | 11.71 | 2343 | 6 | 6 |
4 | 1324.16 | 24 | 12.25 | 2141 | 6 | 6 |
5 | 1123.24 | 24 | 12.65 | 1899 | 6 | 6 |
6 | 413.64 | 24 | 13.56 | 961 | 6 | 7 |
7 | 102.96 | 24 | 14.06 | 490 | 6 | 7 |
8 | 55.68 | 24 | 14.12 | 409 | 6 | 7 |
9 | 0.12 | 250 | 14.26 | 319 | 6 | 180 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 32 | 14.17 | 461 | 6 | 6 |
2 | 1474.44 | 62 | 7.29 | 2266 | 6 | 6 |
3 | 1485.32 | 25 | 11.86 | 2351 | 6 | 6 |
4 | 1315.80 | 24 | 12.33 | 2157 | 6 | 6 |
5 | 909.12 | 24 | 12.98 | 1624 | 6 | 6 |
6 | 455.88 | 24 | 13.50 | 1026 | 6 | 7 |
7 | 105.20 | 24 | 14.01 | 503 | 6 | 7 |
8 | 56.20 | 24 | 14.10 | 416 | 6 | 8 |
9 | 0.04 | 250 | 14.24 | 322 | 6 | 184 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 32 | 14.10 | 461 | 6 | 6 |
2 | 2008.36 | 62 | 5.04 | 3382 | 6 | 6 |
3 | 2044.00 | 25 | 11.30 | 3062 | 6 | 6 |
4 | 1945.36 | 25 | 11.71 | 2978 | 6 | 6 |
5 | 1769.76 | 25 | 11.93 | 2768 | 5 | 6 |
6 | 1344.60 | 25 | 12.45 | 2220 | 6 | 6 |
7 | 875.24 | 25 | 13.08 | 1576 | 6 | 6 |
8 | 164.24 | 25 | 13.89 | 603 | 6 | 7 |
9 | 79.00 | 25 | 14.06 | 455 | 6 | 8 |
10 | 0.04 | 251 | 14.23 | 324 | 6 | 82 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 32 | 14.23 | 442 | 6 | 6 |
2 | 1743.72 | 62 | 6.65 | 2607 | 6 | 6 |
3 | 1704.84 | 25 | 11.56 | 2624 | 6 | 6 |
4 | 1552.52 | 25 | 12.00 | 2463 | 6 | 6 |
5 | 1158.12 | 24 | 12.62 | 1959 | 6 | 6 |
6 | 695.16 | 24 | 13.23 | 1336 | 6 | 6 |
7 | 100.16 | 24 | 14.03 | 493 | 6 | 7 |
8 | 56.12 | 24 | 14.06 | 430 | 6 | 8 |
9 | 25.48 | 24 | 14.17 | 370 | 6 | 8 |
10 | -0.00 | 234 | 14.20 | 325 | 6 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.92 | 32 | 14.10 | 461 | 6 | 6 |
2 | 1536.64 | 62 | 6.93 | 2364 | 6 | 6 |
3 | 1554.16 | 25 | 11.70 | 2432 | 6 | 6 |
4 | 1423.04 | 24 | 12.16 | 2291 | 6 | 6 |
5 | 1008.92 | 24 | 12.84 | 1755 | 6 | 6 |
6 | 580.88 | 24 | 13.41 | 1184 | 6 | 6 |
7 | 84.32 | 24 | 14.01 | 474 | 6 | 7 |
8 | 50.64 | 24 | 14.14 | 407 | 6 | 8 |
9 | -0.00 | 250 | 14.23 | 323 | 6 | 120 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.20 | 32 | 14.23 | 442 | 6 | 6 |
2 | 980.76 | -1 | 14.23 | 442 | 6 | 6 |
3 | 1020.88 | 1 | 9.96 | 1750 | 6 | 6 |
4 | 2000.60 | 62 | 4.81 | 3300 | 6 | 6 |
5 | 2092.28 | 24 | 11.39 | 3114 | 6 | 6 |
6 | 1988.64 | 24 | 11.77 | 3001 | 6 | 6 |
7 | 1810.96 | 24 | 12.05 | 2766 | 6 | 6 |
8 | 1369.56 | 24 | 12.53 | 2220 | 6 | 6 |
9 | 694.92 | 24 | 13.25 | 1349 | 6 | 7 |
10 | 477.72 | 24 | 13.53 | 1047 | 6 | 7 |
11 | 43.00 | 25 | 14.07 | 411 | 6 | 8 |
12 | 5.20 | 25 | 14.18 | 347 | 6 | 8 |
13 | 0.08 | 239 | 14.19 | 331 | 6 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.88 | 31 | 14.10 | 461 | 6 | 6 |
2 | 2004.12 | 62 | 4.84 | 3300 | 6 | 6 |
3 | 2076.32 | 25 | 11.46 | 3136 | 6 | 6 |
4 | 1944.08 | 24 | 11.86 | 2934 | 6 | 6 |
5 | 1767.04 | 24 | 12.12 | 2720 | 6 | 6 |
6 | 1331.64 | 24 | 12.56 | 2164 | 5 | 6 |
7 | 658.00 | 24 | 13.34 | 1286 | 6 | 6 |
8 | 203.64 | 24 | 13.80 | 662 | 6 | 7 |
9 | 53.00 | 24 | 14.07 | 424 | 6 | 8 |
10 | -0.00 | 251 | 14.20 | 329 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.48 | 32 | 14.17 | 423 | 6 | 6 |
2 | 976.56 | -1 | 14.17 | 423 | 6 | 6 |
3 | 2002.92 | 62 | 4.82 | 3345 | 6 | 6 |
4 | 2096.60 | 25 | 11.22 | 3153 | 6 | 6 |
5 | 1973.24 | 24 | 11.72 | 3016 | 6 | 6 |
6 | 1806.80 | 24 | 11.97 | 2801 | 6 | 6 |
7 | 1359.08 | 24 | 12.50 | 2228 | 5 | 6 |
8 | 695.84 | 24 | 13.22 | 1353 | 6 | 6 |
9 | 136.24 | 25 | 13.92 | 553 | 6 | 7 |
10 | 73.48 | 25 | 14.04 | 451 | 6 | 7 |
11 | 15.32 | 25 | 14.22 | 345 | 6 | 8 |
12 | -0.00 | 236 | 14.26 | 322 | 6 | 185 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.96 | 32 | 14.10 | 461 | 6 | 6 |
2 | 1716.60 | 62 | 6.60 | 2565 | 6 | 6 |
3 | 1680.16 | 24 | 11.60 | 2643 | 6 | 6 |
4 | 1511.00 | 24 | 12.11 | 2418 | 5 | 6 |
5 | 1314.08 | 24 | 12.49 | 2138 | 6 | 6 |
6 | 854.52 | 24 | 13.03 | 1563 | 6 | 7 |
7 | 174.36 | 24 | 13.88 | 603 | 6 | 7 |
8 | 84.72 | 24 | 14.05 | 461 | 6 | 8 |
9 | 17.92 | 24 | 14.20 | 345 | 6 | 8 |
10 | -0.08 | 239 | 14.24 | 318 | 6 | 212 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.36 | 32 | 14.04 | 480 | 6 | 6 |
2 | 1793.92 | 62 | 6.29 | 2702 | 6 | 6 |
3 | 1763.08 | 24 | 11.52 | 2699 | 5 | 6 |
4 | 1608.84 | 24 | 12.04 | 2516 | 6 | 6 |
5 | 1403.84 | 24 | 12.31 | 2286 | 6 | 6 |
6 | 751.44 | 24 | 13.14 | 1413 | 6 | 6 |
7 | 167.16 | 24 | 13.84 | 603 | 6 | 7 |
8 | 83.04 | 24 | 13.99 | 472 | 6 | 7 |
9 | 37.40 | 24 | 14.11 | 387 | 6 | 8 |
10 | -0.00 | 242 | 14.22 | 325 | 6 | 171 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 32 | 14.10 | 461 | 6 | 6 |
2 | 981.28 | -1 | 14.10 | 461 | 6 | 6 |
3 | 1025.00 | 1 | 10.28 | 1730 | 6 | 6 |
4 | 1825.32 | 62 | 6.29 | 2722 | 6 | 6 |
5 | 1788.24 | 25 | 11.72 | 2739 | 6 | 6 |
6 | 1648.76 | 25 | 12.04 | 2613 | 6 | 6 |
7 | 1435.88 | 24 | 12.37 | 2318 | 5 | 6 |
8 | 993.72 | 24 | 12.89 | 1745 | 6 | 6 |
9 | 157.52 | 24 | 13.87 | 582 | 6 | 7 |
10 | 77.36 | 24 | 14.02 | 457 | 6 | 7 |
11 | 37.40 | 24 | 14.12 | 391 | 6 | 8 |
12 | -0.00 | 241 | 14.24 | 321 | 6 | 224 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 32 | 14.23 | 442 | 6 | 6 |
2 | 2002.96 | 62 | 4.82 | 3313 | 6 | 6 |
3 | 2088.04 | 25 | 11.30 | 3139 | 6 | 6 |
4 | 1995.16 | 25 | 11.70 | 3032 | 6 | 6 |
5 | 1811.00 | 25 | 11.94 | 2836 | 6 | 6 |
6 | 1378.72 | 24 | 12.48 | 2253 | 6 | 6 |
7 | 683.52 | 24 | 13.27 | 1322 | 6 | 6 |
8 | 127.12 | 24 | 13.91 | 538 | 6 | 7 |
9 | 73.72 | 24 | 14.03 | 449 | 6 | 7 |
10 | 34.76 | 24 | 14.15 | 386 | 6 | 8 |
11 | -0.04 | 239 | 14.26 | 322 | 6 | 244 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.68 | 32 | 14.10 | 461 | 6 | 6 |
2 | 980.68 | -1 | 14.10 | 461 | 6 | 6 |
3 | 1033.40 | 1 | 10.41 | 1788 | 6 | 6 |
4 | 2005.20 | 62 | 5.15 | 3325 | 6 | 6 |
5 | 2089.88 | 24 | 11.46 | 3168 | 6 | 6 |
6 | 1972.92 | 24 | 11.84 | 2990 | 6 | 6 |
7 | 1775.88 | 24 | 12.04 | 2770 | 6 | 6 |
8 | 1340.24 | 24 | 12.53 | 2205 | 6 | 6 |
9 | 663.24 | 24 | 13.23 | 1310 | 6 | 6 |
10 | 181.08 | 25 | 13.81 | 632 | 6 | 7 |
11 | 83.12 | 25 | 13.98 | 472 | 6 | 8 |
12 | -0.00 | 250 | 14.24 | 326 | 6 | 78 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.60 | 32 | 14.17 | 461 | 6 | 6 |
2 | 2002.00 | 62 | 5.04 | 3318 | 6 | 6 |
3 | 2055.16 | 25 | 11.39 | 3111 | 6 | 6 |
4 | 1920.76 | 25 | 11.84 | 2928 | 6 | 6 |
5 | 1740.76 | 25 | 12.04 | 2722 | 6 | 6 |
6 | 1313.88 | 25 | 12.55 | 2172 | 6 | 6 |
7 | 645.84 | 25 | 13.29 | 1270 | 6 | 6 |
8 | 108.36 | 25 | 13.97 | 499 | 6 | 7 |
9 | 61.64 | 25 | 14.13 | 419 | 6 | 7 |
10 | -0.04 | 251 | 14.28 | 319 | 6 | 111 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.76 | 32 | 14.10 | 461 | 6 | 6 |
2 | 2007.00 | 62 | 4.81 | 3274 | 6 | 6 |
3 | 2077.72 | 25 | 11.46 | 3103 | 6 | 6 |
4 | 1954.80 | 25 | 11.72 | 3026 | 6 | 6 |
5 | 1787.04 | 25 | 11.99 | 2786 | 6 | 6 |
6 | 1141.16 | 25 | 12.72 | 1938 | 6 | 6 |
7 | 701.84 | 25 | 13.20 | 1362 | 6 | 7 |
8 | 122.92 | 25 | 13.92 | 522 | 6 | 7 |
9 | 69.72 | 25 | 14.06 | 440 | 6 | 7 |
10 | 0.08 | 251 | 14.28 | 324 | 6 | 93 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.12 | 31 | 14.23 | 442 | 6 | 6 |
2 | 1032.04 | 1 | 10.66 | 1769 | 6 | 6 |
3 | 2002.36 | 62 | 5.56 | 3229 | 6 | 6 |
4 | 2024.12 | 25 | 11.55 | 3059 | 6 | 6 |
5 | 1873.04 | 25 | 11.91 | 2863 | 6 | 6 |
6 | 1672.84 | 25 | 12.18 | 2601 | 6 | 6 |
7 | 1227.60 | 25 | 12.56 | 2085 | 6 | 6 |
8 | 336.56 | 25 | 13.59 | 849 | 6 | 7 |
9 | 96.04 | 25 | 14.00 | 482 | 6 | 7 |
10 | 56.56 | 25 | 14.13 | 412 | 6 | 8 |
11 | -0.00 | 250 | 14.28 | 323 | 6 | 234 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.40 | 32 | 14.23 | 423 | 6 | 6 |
2 | 978.76 | -1 | 14.23 | 423 | 6 | 6 |
3 | 2008.76 | 62 | 5.40 | 3256 | 6 | 6 |
4 | 2070.76 | 25 | 11.38 | 3095 | 6 | 6 |
5 | 1911.36 | 25 | 11.81 | 2932 | 6 | 6 |
6 | 1736.88 | 25 | 12.07 | 2711 | 6 | 6 |
7 | 1531.64 | 25 | 12.32 | 2434 | 6 | 6 |
8 | 569.12 | 25 | 13.34 | 1166 | 6 | 6 |
9 | 151.04 | 25 | 13.87 | 566 | 6 | 7 |
10 | 74.80 | 25 | 14.06 | 438 | 6 | 8 |
11 | 0.04 | 251 | 14.28 | 317 | 6 | 108 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 32 | 14.17 | 442 | 6 | 6 |
2 | 2010.48 | 62 | 5.99 | 2975 | 6 | 6 |
3 | 1931.24 | 25 | 11.59 | 2920 | 6 | 6 |
4 | 1741.48 | 25 | 11.94 | 2736 | 5 | 6 |
5 | 1332.88 | 25 | 12.42 | 2205 | 6 | 6 |
6 | 1119.84 | 25 | 12.76 | 1888 | 6 | 6 |
7 | 192.04 | 25 | 13.79 | 626 | 6 | 7 |
8 | 101.04 | 25 | 13.96 | 491 | 6 | 7 |
9 | 0.08 | 251 | 14.27 | 318 | 6 | 60 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.96 | 32 | 14.10 | 442 | 6 | 6 |
2 | 2002.20 | 62 | 4.85 | 3336 | 6 | 6 |
3 | 2096.12 | 25 | 11.42 | 3155 | 6 | 6 |
4 | 1987.84 | 25 | 11.81 | 2999 | 6 | 6 |
5 | 1826.56 | 25 | 12.02 | 2809 | 6 | 6 |
6 | 1375.76 | 25 | 12.50 | 2236 | 6 | 6 |
7 | 917.96 | 25 | 12.96 | 1643 | 6 | 6 |
8 | 187.68 | 25 | 13.82 | 628 | 6 | 7 |
9 | 87.36 | 25 | 13.99 | 474 | 6 | 8 |
10 | 11.72 | 25 | 14.17 | 351 | 6 | 9 |
11 | -0.04 | 234 | 14.26 | 326 | 6 | 202 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.52 | 32 | 14.10 | 442 | 6 | 6 |
2 | 2010.44 | 62 | 4.86 | 3294 | 6 | 6 |
3 | 2088.08 | 24 | 11.39 | 3155 | 6 | 6 |
4 | 1977.04 | 24 | 11.84 | 2972 | 6 | 6 |
5 | 1816.20 | 24 | 12.00 | 2816 | 6 | 6 |
6 | 1372.20 | 24 | 12.50 | 2243 | 6 | 6 |
7 | 714.36 | 24 | 13.19 | 1368 | 6 | 6 |
8 | 261.20 | 24 | 13.64 | 749 | 6 | 7 |
9 | 65.92 | 24 | 14.05 | 424 | 6 | 7 |
10 | 33.96 | 24 | 14.15 | 374 | 6 | 8 |
11 | 0.20 | 239 | 14.28 | 316 | 6 | 191 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 32 | 14.17 | 461 | 6 | 6 |
2 | 2008.76 | 62 | 6.16 | 3149 | 6 | 6 |
3 | 1943.44 | 25 | 11.59 | 2955 | 6 | 6 |
4 | 1770.88 | 25 | 11.95 | 2749 | 6 | 6 |
5 | 1563.64 | 25 | 12.22 | 2484 | 6 | 6 |
6 | 1087.40 | 25 | 12.77 | 1868 | 6 | 6 |
7 | 354.96 | 25 | 13.55 | 878 | 6 | 7 |
8 | 84.32 | 25 | 14.00 | 466 | 6 | 7 |
9 | 44.12 | 25 | 14.12 | 399 | 6 | 8 |
10 | -0.00 | 244 | 14.26 | 322 | 6 | 204 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.24 | 31 | 14.17 | 461 | 6 | 6 |
2 | 1018.64 | 1 | 10.41 | 1750 | 6 | 6 |
3 | 2003.80 | 62 | 6.73 | 2960 | 6 | 6 |
4 | 1914.88 | 25 | 11.67 | 2897 | 6 | 6 |
5 | 1720.56 | 25 | 12.00 | 2674 | 5 | 6 |
6 | 1515.88 | 24 | 12.29 | 2403 | 6 | 6 |
7 | 802.36 | 24 | 13.07 | 1486 | 6 | 6 |
8 | 181.24 | 24 | 13.80 | 620 | 6 | 7 |
9 | 86.84 | 24 | 13.97 | 474 | 6 | 7 |
10 | -0.08 | 251 | 14.23 | 324 | 6 | 64 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.72 | 32 | 14.23 | 442 | 6 | 6 |
2 | 981.40 | -1 | 14.23 | 442 | 6 | 6 |
3 | 2004.48 | 62 | 4.84 | 3361 | 6 | 6 |
4 | 2068.84 | 25 | 11.44 | 3099 | 6 | 6 |
5 | 1955.88 | 25 | 11.77 | 2976 | 6 | 6 |
6 | 1758.72 | 25 | 12.13 | 2718 | 5 | 6 |
7 | 1326.24 | 25 | 12.50 | 2199 | 6 | 6 |
8 | 864.44 | 25 | 13.05 | 1566 | 6 | 7 |
9 | 102.68 | 25 | 13.96 | 499 | 6 | 7 |
10 | 61.24 | 25 | 14.10 | 430 | 6 | 7 |
11 | -0.08 | 250 | 14.27 | 328 | 6 | 92 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.12 | 32 | 14.17 | 461 | 6 | 6 |
2 | 2004.20 | 62 | 5.08 | 3265 | 6 | 6 |
3 | 2080.88 | 25 | 11.44 | 3116 | 6 | 6 |
4 | 1954.12 | 25 | 11.77 | 2986 | 6 | 6 |
5 | 1777.24 | 25 | 12.07 | 2737 | 6 | 6 |
6 | 1106.64 | 25 | 12.76 | 1882 | 6 | 6 |
7 | 462.12 | 25 | 13.45 | 1020 | 6 | 7 |
8 | 114.84 | 25 | 13.90 | 519 | 6 | 7 |
9 | 59.28 | 25 | 14.08 | 422 | 6 | 8 |
10 | 0.16 | 251 | 14.25 | 325 | 6 | 163 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 32 | 14.10 | 461 | 6 | 6 |
2 | 2007.40 | 62 | 5.76 | 3019 | 6 | 6 |
3 | 1954.20 | 25 | 11.47 | 2955 | 5 | 6 |
4 | 1802.36 | 25 | 11.85 | 2792 | 5 | 6 |
5 | 1607.84 | 25 | 12.21 | 2522 | 6 | 6 |
6 | 1139.92 | 25 | 12.71 | 1930 | 6 | 6 |
7 | 407.80 | 25 | 13.49 | 959 | 6 | 7 |
8 | 83.36 | 25 | 13.97 | 476 | 6 | 7 |
9 | 43.88 | 25 | 14.12 | 403 | 6 | 8 |
10 | -0.00 | 242 | 14.23 | 330 | 6 | 152 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 32 | 14.17 | 461 | 6 | 6 |
2 | 2001.52 | 62 | 4.80 | 3293 | 6 | 6 |
3 | 2085.04 | 25 | 11.33 | 3136 | 6 | 6 |
4 | 1968.24 | 25 | 11.80 | 2978 | 6 | 6 |
5 | 1792.28 | 25 | 12.05 | 2795 | 5 | 6 |
6 | 1389.20 | 25 | 12.52 | 2253 | 6 | 6 |
7 | 698.88 | 25 | 13.19 | 1343 | 6 | 6 |
8 | 121.36 | 25 | 13.91 | 532 | 6 | 7 |
9 | 61.48 | 25 | 14.05 | 443 | 6 | 8 |
10 | 0.04 | 251 | 14.25 | 332 | 6 | 92 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.16 | 32 | 14.23 | 442 | 6 | 6 |
2 | 2002.12 | 62 | 5.08 | 3290 | 6 | 6 |
3 | 2052.52 | 25 | 11.43 | 3089 | 6 | 6 |
4 | 1937.48 | 25 | 11.84 | 2957 | 6 | 6 |
5 | 1743.32 | 25 | 12.08 | 2738 | 5 | 6 |
6 | 1304.12 | 25 | 12.64 | 2128 | 6 | 6 |
7 | 621.28 | 25 | 13.27 | 1249 | 6 | 6 |
8 | 151.44 | 25 | 13.84 | 582 | 6 | 7 |
9 | 41.24 | 25 | 14.12 | 399 | 6 | 7 |
10 | 0.16 | 251 | 14.26 | 329 | 6 | 124 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.32 | 32 | 14.23 | 442 | 6 | 6 |
2 | 2001.40 | 62 | 4.79 | 3245 | 6 | 6 |
3 | 2083.96 | 25 | 11.43 | 3149 | 6 | 6 |
4 | 1948.72 | 25 | 11.87 | 2953 | 6 | 6 |
5 | 1772.12 | 25 | 12.10 | 2753 | 6 | 6 |
6 | 1552.44 | 25 | 12.40 | 2453 | 6 | 6 |
7 | 669.32 | 25 | 13.20 | 1316 | 6 | 6 |
8 | 193.44 | 25 | 13.80 | 635 | 6 | 7 |
9 | 47.32 | 25 | 14.09 | 407 | 6 | 7 |
10 | 1.00 | 250 | 14.26 | 332 | 6 | 88 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.64 | 31 | 14.23 | 442 | 6 | 6 |
2 | 1020.44 | 1 | 10.03 | 1750 | 6 | 6 |
3 | 2003.20 | 62 | 6.11 | 3212 | 6 | 6 |
4 | 1963.68 | 25 | 11.61 | 2980 | 5 | 6 |
5 | 1815.24 | 25 | 11.98 | 2793 | 5 | 6 |
6 | 1407.80 | 25 | 12.43 | 2286 | 6 | 6 |
7 | 974.48 | 25 | 12.92 | 1713 | 6 | 6 |
8 | 295.76 | 25 | 13.62 | 793 | 6 | 7 |
9 | 84.04 | 25 | 13.98 | 470 | 6 | 7 |
10 | 42.68 | 25 | 14.11 | 403 | 6 | 8 |
11 | -0.00 | 242 | 14.28 | 327 | 6 | 204 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.44 | 32 | 14.10 | 461 | 6 | 6 |
2 | 980.16 | -1 | 14.10 | 461 | 6 | 6 |
3 | 2002.72 | 62 | 4.89 | 3400 | 6 | 6 |
4 | 2060.28 | 24 | 11.48 | 3087 | 6 | 6 |
5 | 1949.00 | 25 | 11.78 | 2984 | 6 | 6 |
6 | 1761.60 | 25 | 12.12 | 2736 | 6 | 6 |
7 | 1317.36 | 24 | 12.64 | 2151 | 6 | 6 |
8 | 844.92 | 24 | 13.09 | 1543 | 6 | 7 |
9 | 167.44 | 24 | 13.84 | 597 | 6 | 7 |
10 | 82.16 | 24 | 14.03 | 466 | 6 | 8 |
11 | -0.04 | 251 | 14.26 | 327 | 6 | 74 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 32 | 14.23 | 442 | 6 | 6 |
2 | 2002.56 | 62 | 4.83 | 3299 | 6 | 6 |
3 | 2064.44 | 25 | 11.49 | 3068 | 6 | 6 |
4 | 1962.64 | 25 | 11.88 | 2986 | 6 | 6 |
5 | 1757.92 | 25 | 12.15 | 2739 | 6 | 6 |
6 | 1114.80 | 25 | 12.78 | 1899 | 6 | 6 |
7 | 667.36 | 25 | 13.22 | 1305 | 6 | 6 |
8 | 121.20 | 25 | 13.89 | 522 | 6 | 7 |
9 | 64.24 | 25 | 14.09 | 428 | 6 | 7 |
10 | 0.04 | 251 | 14.28 | 324 | 6 | 123 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.24 | 32 | 14.17 | 442 | 6 | 6 |
2 | 2001.88 | 62 | 4.75 | 3214 | 6 | 6 |
3 | 2061.48 | 25 | 11.51 | 3082 | 6 | 6 |
4 | 1951.76 | 25 | 11.87 | 2965 | 6 | 6 |
5 | 1761.76 | 25 | 12.18 | 2724 | 6 | 6 |
6 | 1124.76 | 25 | 12.77 | 1924 | 6 | 6 |
7 | 495.96 | 25 | 13.43 | 1072 | 6 | 6 |
8 | 133.04 | 25 | 13.87 | 549 | 6 | 7 |
9 | 63.92 | 25 | 14.08 | 445 | 6 | 8 |
10 | 0.12 | 251 | 14.26 | 326 | 6 | 127 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.44 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2001.08 | 62 | 6.24 | 2967 | 6 | 6 |
3 | 1899.00 | 25 | 11.54 | 2907 | 6 | 6 |
4 | 1708.00 | 25 | 12.08 | 2657 | 6 | 6 |
5 | 1495.36 | 25 | 12.45 | 2341 | 6 | 6 |
6 | 813.92 | 25 | 13.07 | 1499 | 6 | 7 |
7 | 172.76 | 25 | 13.82 | 611 | 6 | 7 |
8 | 53.20 | 25 | 14.10 | 414 | 6 | 7 |
9 | 27.40 | 25 | 14.20 | 374 | 6 | 8 |
10 | -0.04 | 236 | 14.27 | 326 | 6 | 195 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.72 | 31 | 14.10 | 461 | 6 | 6 |
2 | 2010.76 | 62 | 4.85 | 3362 | 6 | 6 |
3 | 2124.24 | 25 | 11.37 | 3197 | 6 | 6 |
4 | 2031.68 | 25 | 11.86 | 3070 | 5 | 6 |
5 | 1820.16 | 25 | 12.21 | 2778 | 5 | 6 |
6 | 1383.68 | 25 | 12.60 | 2245 | 6 | 6 |
7 | 915.44 | 25 | 13.08 | 1611 | 6 | 6 |
8 | 182.68 | 25 | 13.81 | 628 | 6 | 7 |
9 | 45.64 | 25 | 14.12 | 403 | 6 | 7 |
10 | 0.04 | 251 | 14.28 | 328 | 6 | 81 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.68 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2007.04 | 62 | 4.84 | 3377 | 6 | 6 |
3 | 2081.68 | 24 | 11.60 | 3101 | 6 | 6 |
4 | 1957.08 | 24 | 12.00 | 2957 | 6 | 6 |
5 | 1780.88 | 25 | 12.27 | 2713 | 6 | 6 |
6 | 1176.68 | 24 | 12.76 | 1988 | 6 | 6 |
7 | 735.92 | 24 | 13.19 | 1399 | 6 | 6 |
8 | 142.40 | 24 | 13.87 | 560 | 6 | 7 |
9 | 41.76 | 24 | 14.18 | 385 | 6 | 7 |
10 | 20.40 | 24 | 14.21 | 368 | 6 | 8 |
11 | 0.08 | 236 | 14.29 | 321 | 6 | 237 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.96 | 32 | 14.10 | 461 | 6 | 6 |
2 | 982.12 | -1 | 14.10 | 461 | 6 | 6 |
3 | 2001.12 | 62 | 4.83 | 3307 | 6 | 6 |
4 | 2074.68 | 25 | 11.64 | 3105 | 6 | 6 |
5 | 1945.60 | 24 | 12.08 | 2949 | 5 | 6 |
6 | 1750.24 | 24 | 12.31 | 2691 | 5 | 6 |
7 | 1337.28 | 24 | 12.64 | 2197 | 6 | 6 |
8 | 658.56 | 24 | 13.27 | 1303 | 6 | 6 |
9 | 188.76 | 24 | 13.82 | 632 | 6 | 7 |
10 | 46.36 | 24 | 14.12 | 405 | 6 | 7 |
11 | 24.40 | 24 | 14.20 | 372 | 6 | 8 |
12 | 13.44 | 24 | 14.27 | 349 | 6 | 11 |
13 | -0.08 | 213 | 14.27 | 331 | 6 | 228 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2003.08 | 62 | 6.72 | 2943 | 6 | 6 |
3 | 1896.20 | 25 | 11.76 | 2874 | 6 | 6 |
4 | 1753.04 | 25 | 12.20 | 2661 | 5 | 6 |
5 | 1335.64 | 25 | 12.60 | 2172 | 6 | 6 |
6 | 863.96 | 25 | 13.11 | 1553 | 6 | 6 |
7 | 178.76 | 25 | 13.82 | 618 | 6 | 7 |
8 | 54.52 | 25 | 14.09 | 424 | 6 | 7 |
9 | 28.56 | 25 | 14.20 | 378 | 6 | 8 |
10 | -0.08 | 234 | 14.28 | 324 | 6 | 141 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.68 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2012.52 | 62 | 4.87 | 3409 | 6 | 6 |
3 | 2107.96 | 25 | 11.64 | 3161 | 6 | 6 |
4 | 2002.56 | 25 | 12.01 | 3013 | 6 | 6 |
5 | 1817.08 | 25 | 12.23 | 2828 | 6 | 6 |
6 | 1371.40 | 25 | 12.62 | 2239 | 6 | 6 |
7 | 667.04 | 25 | 13.26 | 1318 | 6 | 6 |
8 | 189.92 | 25 | 13.81 | 639 | 6 | 7 |
9 | 48.80 | 25 | 14.13 | 405 | 6 | 7 |
10 | -0.00 | 251 | 14.29 | 323 | 6 | 96 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 31 | 14.17 | 461 | 6 | 6 |
2 | 2005.84 | 62 | 5.20 | 3255 | 6 | 6 |
3 | 2059.68 | 25 | 11.65 | 3132 | 6 | 6 |
4 | 1914.24 | 25 | 12.07 | 2909 | 6 | 6 |
5 | 1731.96 | 25 | 12.27 | 2716 | 6 | 6 |
6 | 1079.92 | 25 | 12.91 | 1839 | 6 | 6 |
7 | 408.76 | 25 | 13.54 | 951 | 6 | 7 |
8 | 101.52 | 25 | 13.96 | 505 | 6 | 7 |
9 | 27.04 | 25 | 14.21 | 370 | 6 | 7 |
10 | 0.08 | 249 | 14.29 | 324 | 6 | 240 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2002.44 | 62 | 6.06 | 3142 | 6 | 6 |
3 | 1971.16 | 24 | 11.83 | 2988 | 6 | 6 |
4 | 1836.36 | 24 | 12.09 | 2834 | 6 | 6 |
5 | 1619.68 | 24 | 12.34 | 2574 | 6 | 6 |
6 | 915.00 | 24 | 13.10 | 1615 | 6 | 6 |
7 | 284.12 | 24 | 13.67 | 782 | 6 | 7 |
8 | 80.64 | 24 | 14.05 | 461 | 6 | 7 |
9 | 21.40 | 24 | 14.21 | 365 | 6 | 7 |
10 | 0.08 | 247 | 14.29 | 326 | 6 | 220 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.92 | 31 | 14.29 | 423 | 6 | 6 |
2 | 2002.24 | 62 | 7.03 | 2980 | 6 | 6 |
3 | 1900.24 | 24 | 11.91 | 2878 | 6 | 6 |
4 | 1730.60 | 24 | 12.23 | 2657 | 5 | 6 |
5 | 1297.36 | 24 | 12.66 | 2113 | 6 | 6 |
6 | 866.84 | 24 | 13.06 | 1566 | 6 | 6 |
7 | 191.92 | 24 | 13.80 | 632 | 6 | 7 |
8 | 92.24 | 24 | 14.02 | 484 | 6 | 8 |
9 | 18.40 | 24 | 14.24 | 349 | 6 | 8 |
10 | 0.04 | 239 | 14.26 | 325 | 6 | 215 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.24 | 32 | 14.23 | 442 | 6 | 6 |
2 | 960.28 | -1 | 14.23 | 442 | 6 | 6 |
3 | 2008.80 | 62 | 6.96 | 2995 | 6 | 6 |
4 | 1942.00 | 24 | 11.85 | 2936 | 6 | 6 |
5 | 1759.56 | 24 | 12.19 | 2695 | 6 | 6 |
6 | 1554.60 | 24 | 12.37 | 2482 | 6 | 6 |
7 | 823.76 | 24 | 13.10 | 1513 | 6 | 6 |
8 | 175.44 | 24 | 13.81 | 611 | 6 | 7 |
9 | 90.20 | 24 | 14.02 | 476 | 6 | 8 |
10 | 17.56 | 24 | 14.23 | 353 | 6 | 8 |
11 | 0.44 | 239 | 14.27 | 323 | 6 | 176 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.28 | 32 | 14.17 | 461 | 6 | 6 |
2 | 2006.76 | 62 | 6.96 | 2990 | 6 | 6 |
3 | 1897.04 | 24 | 11.77 | 2918 | 6 | 6 |
4 | 1727.88 | 24 | 12.20 | 2684 | 6 | 6 |
5 | 1308.20 | 24 | 12.61 | 2168 | 5 | 6 |
6 | 607.64 | 24 | 13.30 | 1226 | 6 | 6 |
7 | 167.44 | 24 | 13.82 | 603 | 6 | 7 |
8 | 81.60 | 24 | 14.07 | 459 | 6 | 8 |
9 | 18.96 | 24 | 14.23 | 357 | 6 | 8 |
10 | -0.00 | 236 | 14.25 | 324 | 6 | 176 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.16 | 31 | 14.17 | 461 | 6 | 6 |
2 | 2001.96 | 62 | 7.33 | 2954 | 6 | 6 |
3 | 1868.20 | 25 | 11.92 | 2843 | 5 | 6 |
4 | 1683.08 | 25 | 12.27 | 2605 | 6 | 6 |
5 | 1230.52 | 24 | 12.68 | 2061 | 6 | 6 |
6 | 557.52 | 24 | 13.38 | 1155 | 6 | 6 |
7 | 143.44 | 24 | 13.92 | 558 | 6 | 7 |
8 | 65.84 | 24 | 14.11 | 434 | 6 | 8 |
9 | 0.08 | 251 | 14.25 | 322 | 6 | 91 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.44 | 31 | 14.17 | 461 | 6 | 6 |
2 | 2007.16 | 62 | 7.07 | 2913 | 6 | 6 |
3 | 1901.80 | 24 | 11.84 | 2913 | 6 | 6 |
4 | 1685.28 | 25 | 12.29 | 2595 | 6 | 6 |
5 | 1475.24 | 24 | 12.46 | 2370 | 6 | 6 |
6 | 725.80 | 24 | 13.18 | 1388 | 6 | 6 |
7 | 130.16 | 24 | 13.94 | 538 | 6 | 7 |
8 | 66.40 | 24 | 14.09 | 442 | 6 | 8 |
9 | 0.16 | 251 | 14.23 | 330 | 6 | 80 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.56 | 31 | 14.17 | 461 | 6 | 6 |
2 | 2004.88 | 62 | 7.41 | 2928 | 6 | 6 |
3 | 1876.32 | 25 | 11.89 | 2874 | 5 | 6 |
4 | 1676.52 | 24 | 12.18 | 2649 | 5 | 6 |
5 | 1486.16 | 24 | 12.48 | 2362 | 6 | 6 |
6 | 778.76 | 24 | 13.14 | 1459 | 6 | 6 |
7 | 140.76 | 24 | 13.91 | 553 | 6 | 7 |
8 | 64.68 | 24 | 14.11 | 436 | 6 | 8 |
9 | -0.00 | 251 | 14.23 | 327 | 6 | 82 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.76 | 31 | 14.23 | 461 | 6 | 6 |
2 | 980.64 | -1 | 14.23 | 461 | 6 | 6 |
3 | 1035.96 | 1 | 11.62 | 1750 | 6 | 6 |
4 | 2002.88 | 62 | 7.44 | 2957 | 6 | 6 |
5 | 1876.56 | 24 | 11.91 | 2874 | 6 | 6 |
6 | 1673.56 | 25 | 12.25 | 2599 | 6 | 6 |
7 | 1026.88 | 24 | 12.90 | 1765 | 6 | 6 |
8 | 576.52 | 24 | 13.33 | 1178 | 6 | 6 |
9 | 89.84 | 24 | 14.03 | 474 | 6 | 7 |
10 | 45.32 | 24 | 14.19 | 399 | 6 | 7 |
11 | 0.04 | 250 | 14.26 | 324 | 6 | 118 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2009.56 | 62 | 7.48 | 2970 | 6 | 6 |
3 | 1870.56 | 24 | 11.88 | 2876 | 6 | 6 |
4 | 1659.72 | 24 | 12.24 | 2591 | 5 | 6 |
5 | 1200.28 | 24 | 12.74 | 2005 | 6 | 6 |
6 | 535.48 | 24 | 13.40 | 1118 | 6 | 6 |
7 | 137.64 | 24 | 13.89 | 551 | 6 | 7 |
8 | 34.24 | 24 | 14.17 | 389 | 6 | 8 |
9 | -0.00 | 251 | 14.23 | 326 | 6 | 119 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.96 | 32 | 14.17 | 480 | 6 | 6 |
2 | 972.88 | -1 | 14.17 | 480 | 6 | 6 |
3 | 2003.08 | 62 | 7.69 | 2947 | 6 | 6 |
4 | 1863.60 | 24 | 12.00 | 2822 | 6 | 6 |
5 | 1691.64 | 24 | 12.24 | 2610 | 6 | 6 |
6 | 1071.12 | 24 | 12.85 | 1835 | 6 | 6 |
7 | 409.60 | 24 | 13.52 | 945 | 6 | 6 |
8 | 98.04 | 24 | 14.02 | 491 | 6 | 7 |
9 | 53.48 | 24 | 14.17 | 411 | 6 | 8 |
10 | 0.12 | 251 | 14.25 | 320 | 6 | 168 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.72 | 31 | 14.23 | 442 | 6 | 6 |
2 | 1002.44 | 2 | 12.38 | 1711 | 6 | 6 |
3 | 964.24 | -1 | 12.38 | 1711 | 6 | 6 |
4 | 2005.00 | 62 | 8.06 | 2958 | 6 | 6 |
5 | 1848.88 | 25 | 11.98 | 2824 | 6 | 6 |
6 | 1641.08 | 25 | 12.26 | 2570 | 6 | 6 |
7 | 1008.20 | 24 | 12.92 | 1770 | 6 | 6 |
8 | 552.12 | 24 | 13.37 | 1149 | 6 | 7 |
9 | 125.84 | 24 | 13.94 | 539 | 6 | 8 |
10 | 60.48 | 24 | 14.08 | 438 | 6 | 8 |
11 | -0.04 | 250 | 14.24 | 326 | 6 | 173 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2002.20 | 62 | 8.16 | 2943 | 6 | 6 |
3 | 1861.64 | 25 | 11.99 | 2851 | 6 | 6 |
4 | 1648.28 | 25 | 12.32 | 2559 | 6 | 6 |
5 | 1189.56 | 24 | 12.78 | 1974 | 6 | 6 |
6 | 459.72 | 25 | 13.45 | 1024 | 6 | 7 |
7 | 97.76 | 24 | 14.01 | 491 | 6 | 7 |
8 | 53.92 | 24 | 14.13 | 428 | 6 | 8 |
9 | 0.04 | 249 | 14.24 | 322 | 6 | 190 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.44 | 32 | 14.23 | 461 | 6 | 6 |
2 | 976.44 | -1 | 14.23 | 461 | 6 | 6 |
3 | 2004.24 | 62 | 7.94 | 2958 | 6 | 6 |
4 | 1823.28 | 24 | 11.98 | 2807 | 6 | 6 |
5 | 1632.88 | 25 | 12.26 | 2568 | 6 | 6 |
6 | 1185.60 | 25 | 12.67 | 2020 | 6 | 6 |
7 | 497.28 | 24 | 13.43 | 1072 | 6 | 7 |
8 | 113.84 | 24 | 14.02 | 509 | 6 | 7 |
9 | 54.28 | 24 | 14.14 | 422 | 6 | 8 |
10 | -0.04 | 250 | 14.23 | 328 | 6 | 172 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 32 | 14.17 | 461 | 6 | 6 |
2 | 2002.36 | 62 | 7.96 | 2964 | 6 | 6 |
3 | 1858.88 | 24 | 11.95 | 2847 | 6 | 6 |
4 | 1648.76 | 25 | 12.26 | 2586 | 5 | 6 |
5 | 993.08 | 24 | 12.96 | 1732 | 6 | 6 |
6 | 319.24 | 24 | 13.62 | 830 | 6 | 6 |
7 | 144.88 | 24 | 13.88 | 574 | 6 | 7 |
8 | 36.40 | 24 | 14.20 | 393 | 6 | 7 |
9 | 0.12 | 250 | 14.24 | 323 | 6 | 224 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.12 | 31 | 14.17 | 461 | 6 | 6 |
2 | 1028.68 | 1 | 11.75 | 1769 | 6 | 6 |
3 | 2004.00 | 62 | 8.29 | 2963 | 6 | 6 |
4 | 1866.04 | 24 | 12.05 | 2830 | 5 | 6 |
5 | 1667.36 | 24 | 12.26 | 2611 | 6 | 6 |
6 | 984.64 | 24 | 12.94 | 1718 | 6 | 6 |
7 | 506.88 | 24 | 13.44 | 1076 | 6 | 7 |
8 | 118.60 | 24 | 14.00 | 526 | 6 | 7 |
9 | 58.84 | 24 | 14.13 | 432 | 6 | 8 |
10 | 12.40 | 24 | 14.24 | 353 | 6 | 8 |
11 | -0.00 | 226 | 14.24 | 320 | 6 | 212 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.12 | 31 | 14.23 | 442 | 6 | 6 |
2 | 974.28 | -1 | 14.23 | 442 | 6 | 6 |
3 | 1019.12 | 1 | 10.22 | 1711 | 6 | 6 |
4 | 2005.48 | 62 | 8.48 | 2950 | 6 | 6 |
5 | 1833.36 | 24 | 12.05 | 2809 | 6 | 6 |
6 | 1627.20 | 24 | 12.36 | 2526 | 6 | 6 |
7 | 958.20 | 24 | 12.95 | 1689 | 6 | 6 |
8 | 276.16 | 24 | 13.70 | 757 | 6 | 6 |
9 | 127.44 | 24 | 13.99 | 528 | 6 | 7 |
10 | 58.20 | 24 | 14.15 | 422 | 6 | 8 |
11 | -0.00 | 247 | 14.23 | 320 | 6 | 195 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.72 | 30 | 14.29 | 442 | 6 | 6 |
2 | 1039.96 | 1 | 12.12 | 1769 | 6 | 6 |
3 | 2003.12 | 62 | 8.85 | 2973 | 6 | 6 |
4 | 1839.80 | 24 | 12.05 | 2812 | 6 | 6 |
5 | 1632.36 | 24 | 12.36 | 2535 | 6 | 6 |
6 | 960.68 | 24 | 12.97 | 1684 | 6 | 6 |
7 | 250.56 | 24 | 13.75 | 722 | 6 | 6 |
8 | 114.44 | 24 | 14.01 | 524 | 6 | 7 |
9 | 53.60 | 24 | 14.21 | 407 | 6 | 8 |
10 | 0.08 | 247 | 14.24 | 317 | 6 | 249 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.40 | 31 | 14.36 | 423 | 6 | 6 |
2 | 982.48 | -1 | 14.36 | 423 | 6 | 6 |
3 | 2002.76 | 62 | 8.90 | 2967 | 6 | 6 |
4 | 1833.28 | 24 | 12.07 | 2816 | 6 | 6 |
5 | 1619.12 | 24 | 12.35 | 2526 | 6 | 6 |
6 | 939.16 | 24 | 12.98 | 1664 | 6 | 6 |
7 | 460.24 | 24 | 13.49 | 1022 | 6 | 7 |
8 | 107.64 | 24 | 14.07 | 495 | 6 | 7 |
9 | 55.32 | 24 | 14.21 | 407 | 6 | 8 |
10 | 0.80 | 247 | 14.25 | 319 | 6 | 230 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.16 | 31 | 14.23 | 442 | 6 | 6 |
2 | 970.60 | -1 | 14.23 | 442 | 6 | 6 |
3 | 1027.92 | 1 | 11.43 | 1769 | 6 | 6 |
4 | 2004.36 | 62 | 9.07 | 2985 | 6 | 6 |
5 | 1845.16 | 25 | 12.05 | 2832 | 6 | 6 |
6 | 1642.64 | 24 | 12.34 | 2557 | 6 | 6 |
7 | 939.80 | 24 | 12.98 | 1672 | 6 | 6 |
8 | 247.44 | 24 | 13.77 | 716 | 6 | 7 |
9 | 115.76 | 24 | 14.07 | 515 | 6 | 7 |
10 | 57.20 | 24 | 14.19 | 417 | 6 | 8 |
11 | 0.08 | 242 | 14.25 | 320 | 6 | 152 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.40 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2001.92 | 62 | 9.15 | 3011 | 6 | 6 |
3 | 1801.52 | 25 | 12.13 | 2770 | 6 | 6 |
4 | 1596.24 | 24 | 12.39 | 2499 | 6 | 6 |
5 | 904.24 | 24 | 13.02 | 1613 | 6 | 6 |
6 | 214.36 | 24 | 13.80 | 670 | 6 | 7 |
7 | 100.92 | 24 | 14.08 | 488 | 6 | 7 |
8 | 47.64 | 24 | 14.23 | 393 | 6 | 8 |
9 | 0.04 | 242 | 14.22 | 322 | 6 | 162 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.96 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2001.64 | 62 | 9.33 | 2972 | 6 | 6 |
3 | 1829.76 | 24 | 12.07 | 2805 | 6 | 6 |
4 | 1393.00 | 24 | 12.47 | 2289 | 6 | 6 |
5 | 929.88 | 24 | 12.96 | 1670 | 6 | 6 |
6 | 235.64 | 24 | 13.80 | 703 | 6 | 7 |
7 | 107.56 | 24 | 14.03 | 507 | 6 | 8 |
8 | 52.32 | 24 | 14.20 | 409 | 6 | 8 |
9 | 0.84 | 242 | 14.20 | 326 | 6 | 180 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 30 | 14.23 | 442 | 6 | 6 |
2 | 1021.60 | 1 | 11.37 | 1807 | 6 | 6 |
3 | 2002.88 | 62 | 9.40 | 3013 | 6 | 6 |
4 | 1815.40 | 25 | 12.14 | 2767 | 6 | 6 |
5 | 1364.56 | 24 | 12.53 | 2224 | 6 | 6 |
6 | 692.92 | 24 | 13.26 | 1341 | 6 | 6 |
7 | 217.32 | 24 | 13.81 | 682 | 6 | 7 |
8 | 55.64 | 24 | 14.12 | 430 | 6 | 7 |
9 | 25.84 | 24 | 14.24 | 372 | 6 | 8 |
10 | -0.00 | 239 | 14.21 | 325 | 6 | 212 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 31 | 14.17 | 461 | 6 | 6 |
2 | 978.04 | -1 | 14.17 | 461 | 6 | 6 |
3 | 2003.60 | 62 | 9.47 | 3003 | 6 | 6 |
4 | 1824.72 | 25 | 12.05 | 2818 | 6 | 6 |
5 | 1368.56 | 24 | 12.54 | 2234 | 5 | 6 |
6 | 701.08 | 24 | 13.18 | 1362 | 6 | 6 |
7 | 241.20 | 24 | 13.78 | 711 | 6 | 7 |
8 | 55.12 | 24 | 14.14 | 420 | 6 | 7 |
9 | 27.84 | 24 | 14.26 | 370 | 6 | 8 |
10 | 13.76 | 24 | 14.23 | 349 | 6 | 10 |
11 | -0.12 | 215 | 14.21 | 319 | 6 | 184 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.24 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2003.76 | 62 | 9.60 | 2966 | 6 | 6 |
3 | 1808.80 | 25 | 12.11 | 2755 | 6 | 6 |
4 | 1590.08 | 25 | 12.29 | 2530 | 6 | 6 |
5 | 866.08 | 25 | 13.05 | 1555 | 6 | 6 |
6 | 167.04 | 25 | 13.91 | 592 | 6 | 7 |
7 | 78.04 | 24 | 14.12 | 461 | 6 | 8 |
8 | 16.00 | 25 | 14.26 | 355 | 6 | 9 |
9 | -0.04 | 236 | 14.18 | 323 | 6 | 176 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.76 | 31 | 14.29 | 461 | 6 | 6 |
2 | 2002.52 | 62 | 9.63 | 2972 | 6 | 6 |
3 | 1808.64 | 25 | 12.12 | 2772 | 6 | 6 |
4 | 1381.36 | 24 | 12.51 | 2251 | 6 | 6 |
5 | 708.56 | 24 | 13.21 | 1368 | 6 | 6 |
6 | 247.44 | 24 | 13.76 | 728 | 6 | 7 |
7 | 61.00 | 24 | 14.10 | 436 | 6 | 7 |
8 | 31.80 | 24 | 14.20 | 386 | 6 | 8 |
9 | -0.00 | 239 | 14.21 | 323 | 6 | 176 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.36 | 31 | 14.36 | 423 | 6 | 6 |
2 | 2004.36 | 62 | 9.70 | 2969 | 6 | 6 |
3 | 1823.64 | 25 | 12.08 | 2807 | 6 | 6 |
4 | 1195.04 | 24 | 12.74 | 1990 | 6 | 6 |
5 | 745.04 | 24 | 13.15 | 1413 | 6 | 6 |
6 | 153.96 | 24 | 13.97 | 566 | 6 | 7 |
7 | 81.08 | 24 | 14.11 | 461 | 6 | 7 |
8 | 40.48 | 25 | 14.23 | 385 | 6 | 8 |
9 | -0.00 | 236 | 14.23 | 319 | 6 | 165 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.32 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2001.64 | 62 | 9.85 | 2956 | 6 | 6 |
3 | 1815.76 | 25 | 12.10 | 2776 | 6 | 6 |
4 | 1597.28 | 24 | 12.31 | 2526 | 6 | 6 |
5 | 653.92 | 25 | 13.31 | 1272 | 6 | 6 |
6 | 192.92 | 24 | 13.89 | 635 | 6 | 7 |
7 | 91.56 | 25 | 14.08 | 474 | 6 | 8 |
8 | 0.12 | 251 | 14.21 | 319 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.36 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2002.72 | 62 | 9.79 | 2990 | 6 | 6 |
3 | 1804.24 | 25 | 12.11 | 2793 | 6 | 6 |
4 | 1358.40 | 24 | 12.51 | 2236 | 6 | 6 |
5 | 667.84 | 25 | 13.27 | 1291 | 6 | 6 |
6 | 121.00 | 24 | 14.00 | 520 | 6 | 7 |
7 | 70.40 | 24 | 14.16 | 442 | 6 | 7 |
8 | 0.28 | 251 | 14.21 | 315 | 6 | 76 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.04 | 32 | 14.29 | 442 | 6 | 6 |
2 | 975.80 | -1 | 14.29 | 442 | 6 | 6 |
3 | 1019.32 | 1 | 9.58 | 1769 | 6 | 6 |
4 | 2003.00 | 62 | 10.06 | 2971 | 6 | 6 |
5 | 1817.56 | 25 | 12.14 | 2792 | 6 | 6 |
6 | 1386.36 | 24 | 12.54 | 2265 | 5 | 6 |
7 | 697.20 | 24 | 13.22 | 1351 | 6 | 6 |
8 | 122.48 | 24 | 14.02 | 520 | 6 | 7 |
9 | 71.40 | 24 | 14.18 | 434 | 6 | 7 |
10 | 35.08 | 24 | 14.24 | 376 | 6 | 8 |
11 | -0.00 | 236 | 14.21 | 315 | 6 | 199 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2008.36 | 62 | 10.11 | 2996 | 6 | 6 |
3 | 1621.84 | 24 | 12.34 | 2534 | 6 | 6 |
4 | 1187.80 | 24 | 12.77 | 1972 | 6 | 6 |
5 | 528.92 | 24 | 13.42 | 1111 | 6 | 6 |
6 | 142.48 | 24 | 13.97 | 557 | 6 | 7 |
7 | 72.92 | 25 | 14.15 | 440 | 6 | 7 |
8 | 0.08 | 251 | 14.20 | 317 | 6 | 88 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 31 | 14.23 | 442 | 6 | 6 |
2 | 1019.12 | 1 | 10.09 | 1807 | 6 | 6 |
3 | 2003.00 | 62 | 10.22 | 2998 | 6 | 6 |
4 | 1795.92 | 24 | 12.18 | 2766 | 6 | 6 |
5 | 1579.44 | 24 | 12.38 | 2488 | 6 | 6 |
6 | 640.40 | 24 | 13.29 | 1268 | 6 | 6 |
7 | 178.68 | 24 | 13.87 | 620 | 6 | 7 |
8 | 52.40 | 24 | 14.19 | 409 | 6 | 7 |
9 | 25.52 | 24 | 14.27 | 366 | 6 | 8 |
10 | 0.04 | 236 | 14.20 | 318 | 6 | 169 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.72 | 31 | 14.29 | 423 | 6 | 6 |
2 | 967.08 | -1 | 14.29 | 423 | 6 | 6 |
3 | 2008.44 | 62 | 10.28 | 2978 | 6 | 6 |
4 | 1818.76 | 24 | 12.17 | 2805 | 6 | 6 |
5 | 1383.12 | 24 | 12.55 | 2232 | 6 | 6 |
6 | 711.88 | 24 | 13.24 | 1357 | 6 | 6 |
7 | 138.08 | 24 | 14.03 | 536 | 6 | 7 |
8 | 77.72 | 24 | 14.14 | 447 | 6 | 7 |
9 | 15.92 | 24 | 14.28 | 349 | 6 | 7 |
10 | 0.08 | 236 | 14.21 | 318 | 6 | 204 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.16 | 31 | 14.36 | 423 | 6 | 6 |
2 | 2000.52 | 62 | 10.20 | 3013 | 6 | 6 |
3 | 1786.36 | 24 | 12.21 | 2747 | 6 | 6 |
4 | 1335.24 | 25 | 12.61 | 2192 | 6 | 6 |
5 | 643.88 | 24 | 13.32 | 1264 | 6 | 6 |
6 | 178.76 | 24 | 13.90 | 613 | 6 | 7 |
7 | 87.88 | 24 | 14.17 | 461 | 6 | 7 |
8 | 3.20 | 24 | 14.29 | 330 | 6 | 8 |
9 | 0.04 | 233 | 14.21 | 314 | 6 | 194 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.12 | 31 | 14.17 | 461 | 6 | 6 |
2 | 2001.68 | 62 | 10.30 | 2978 | 6 | 6 |
3 | 1608.04 | 25 | 12.37 | 2507 | 6 | 6 |
4 | 1401.72 | 24 | 12.61 | 2251 | 6 | 6 |
5 | 485.56 | 24 | 13.51 | 1047 | 6 | 6 |
6 | 125.60 | 24 | 13.97 | 534 | 6 | 7 |
7 | 58.60 | 24 | 14.15 | 426 | 6 | 8 |
8 | -0.00 | 251 | 14.16 | 321 | 6 | 86 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.76 | 31 | 14.29 | 461 | 6 | 6 |
2 | 2000.84 | 62 | 10.31 | 2994 | 6 | 6 |
3 | 1793.24 | 25 | 12.17 | 2774 | 6 | 6 |
4 | 1142.32 | 25 | 12.82 | 1924 | 6 | 6 |
5 | 690.84 | 25 | 13.25 | 1337 | 6 | 7 |
6 | 122.56 | 25 | 14.05 | 517 | 6 | 7 |
7 | 66.92 | 24 | 14.17 | 434 | 6 | 7 |
8 | 0.12 | 251 | 14.20 | 318 | 6 | 102 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.40 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2002.64 | 62 | 10.33 | 3027 | 6 | 6 |
3 | 1788.88 | 24 | 12.17 | 2780 | 5 | 6 |
4 | 1131.64 | 24 | 12.86 | 1907 | 6 | 6 |
5 | 697.40 | 24 | 13.27 | 1347 | 6 | 7 |
6 | 135.84 | 24 | 14.01 | 539 | 6 | 6 |
7 | 77.16 | 24 | 14.17 | 445 | 6 | 7 |
8 | 0.08 | 251 | 14.23 | 317 | 6 | 81 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.00 | 31 | 14.29 | 442 | 6 | 6 |
2 | 982.20 | -1 | 14.29 | 442 | 6 | 6 |
3 | 1032.36 | 1 | 11.75 | 1807 | 6 | 6 |
4 | 2001.92 | 62 | 10.39 | 3019 | 6 | 6 |
5 | 1791.28 | 25 | 12.22 | 2745 | 6 | 6 |
6 | 1124.00 | 25 | 12.89 | 1882 | 6 | 6 |
7 | 453.92 | 24 | 13.52 | 1015 | 6 | 6 |
8 | 110.00 | 24 | 14.06 | 511 | 6 | 7 |
9 | 54.64 | 24 | 14.16 | 424 | 6 | 8 |
10 | -0.04 | 251 | 14.14 | 324 | 6 | 96 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.76 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2003.12 | 62 | 10.40 | 3019 | 6 | 6 |
3 | 1790.36 | 24 | 12.15 | 2791 | 5 | 6 |
4 | 1328.72 | 25 | 12.59 | 2197 | 6 | 6 |
5 | 629.08 | 24 | 13.29 | 1280 | 6 | 6 |
6 | 111.40 | 24 | 14.05 | 505 | 6 | 6 |
7 | 66.60 | 24 | 14.19 | 428 | 6 | 7 |
8 | 0.12 | 250 | 14.22 | 315 | 6 | 89 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2008.36 | 62 | 10.47 | 3012 | 6 | 6 |
3 | 1793.52 | 24 | 12.20 | 2791 | 6 | 6 |
4 | 1127.04 | 24 | 12.85 | 1918 | 6 | 6 |
5 | 676.16 | 24 | 13.30 | 1322 | 6 | 6 |
6 | 179.88 | 24 | 13.94 | 609 | 6 | 7 |
7 | 84.60 | 24 | 14.16 | 461 | 6 | 7 |
8 | 0.08 | 251 | 14.17 | 323 | 6 | 86 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2002.88 | 62 | 10.47 | 3056 | 6 | 6 |
3 | 1803.36 | 24 | 12.20 | 2778 | 6 | 6 |
4 | 1139.64 | 25 | 12.80 | 1947 | 6 | 6 |
5 | 675.08 | 24 | 13.31 | 1322 | 6 | 6 |
6 | 103.68 | 24 | 14.04 | 497 | 6 | 7 |
7 | 61.36 | 24 | 14.17 | 426 | 6 | 7 |
8 | 0.12 | 251 | 14.18 | 317 | 6 | 91 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 31 | 14.36 | 442 | 6 | 6 |
2 | 2005.88 | 62 | 10.56 | 3026 | 6 | 6 |
3 | 1799.76 | 25 | 12.20 | 2788 | 6 | 6 |
4 | 1109.44 | 24 | 12.83 | 1911 | 6 | 6 |
5 | 460.92 | 24 | 13.52 | 1020 | 6 | 7 |
6 | 119.56 | 24 | 14.03 | 520 | 6 | 7 |
7 | 64.92 | 24 | 14.22 | 422 | 6 | 7 |
8 | -0.00 | 251 | 14.19 | 314 | 6 | 107 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.20 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2003.12 | 62 | 10.60 | 3030 | 6 | 6 |
3 | 1792.32 | 24 | 12.27 | 2755 | 6 | 6 |
4 | 1126.88 | 24 | 12.82 | 1915 | 6 | 6 |
5 | 677.48 | 24 | 13.29 | 1318 | 6 | 6 |
6 | 106.68 | 24 | 14.05 | 501 | 6 | 7 |
7 | 61.48 | 24 | 14.18 | 430 | 6 | 7 |
8 | 0.04 | 251 | 14.15 | 321 | 6 | 90 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.68 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2003.28 | 62 | 10.62 | 2992 | 6 | 6 |
3 | 1801.76 | 24 | 12.23 | 2782 | 6 | 6 |
4 | 1146.32 | 25 | 12.83 | 1940 | 6 | 6 |
5 | 676.08 | 24 | 13.31 | 1310 | 6 | 6 |
6 | 95.40 | 24 | 14.05 | 486 | 6 | 7 |
7 | 52.68 | 24 | 14.16 | 422 | 6 | 8 |
8 | -0.00 | 250 | 14.10 | 324 | 6 | 87 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 31 | 14.10 | 461 | 6 | 6 |
2 | 2006.08 | 62 | 10.62 | 3041 | 6 | 6 |
3 | 1788.44 | 25 | 12.19 | 2788 | 6 | 6 |
4 | 1115.68 | 25 | 12.87 | 1889 | 6 | 6 |
5 | 436.32 | 24 | 13.57 | 982 | 6 | 6 |
6 | 101.08 | 24 | 14.02 | 499 | 6 | 7 |
7 | 53.52 | 24 | 14.20 | 418 | 6 | 8 |
8 | -0.08 | 251 | 14.11 | 325 | 6 | 126 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2006.36 | 62 | 10.68 | 3035 | 6 | 6 |
3 | 1797.60 | 25 | 12.24 | 2778 | 6 | 6 |
4 | 1129.48 | 24 | 12.80 | 1939 | 6 | 6 |
5 | 448.24 | 24 | 13.55 | 1003 | 6 | 6 |
6 | 110.00 | 24 | 14.04 | 511 | 6 | 7 |
7 | 61.20 | 24 | 14.15 | 432 | 6 | 8 |
8 | 0.04 | 251 | 14.13 | 320 | 6 | 106 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.60 | 31 | 14.17 | 461 | 6 | 6 |
2 | 2010.44 | 62 | 10.65 | 3048 | 6 | 6 |
3 | 1791.68 | 25 | 12.23 | 2755 | 5 | 6 |
4 | 1085.80 | 24 | 12.90 | 1853 | 6 | 6 |
5 | 433.00 | 25 | 13.54 | 982 | 6 | 6 |
6 | 102.60 | 24 | 14.05 | 501 | 6 | 7 |
7 | 48.12 | 24 | 14.18 | 410 | 6 | 8 |
8 | 0.96 | 251 | 14.07 | 327 | 6 | 109 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.96 | 31 | 14.23 | 442 | 6 | 6 |
2 | 2005.12 | 62 | 10.71 | 3041 | 6 | 6 |
3 | 1590.16 | 24 | 12.40 | 2522 | 5 | 6 |
4 | 1145.32 | 25 | 12.85 | 1934 | 6 | 6 |
5 | 434.88 | 24 | 13.55 | 991 | 6 | 6 |
6 | 97.16 | 24 | 14.03 | 499 | 6 | 7 |
7 | 51.44 | 24 | 14.18 | 418 | 6 | 8 |
8 | -0.04 | 251 | 14.09 | 327 | 6 | 127 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.64 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2007.00 | 62 | 10.70 | 3031 | 6 | 6 |
3 | 1820.40 | 25 | 12.21 | 2817 | 5 | 6 |
4 | 1158.48 | 25 | 12.79 | 1961 | 6 | 6 |
5 | 461.08 | 25 | 13.51 | 1030 | 6 | 7 |
6 | 110.28 | 24 | 14.01 | 520 | 6 | 7 |
7 | 57.92 | 25 | 14.14 | 434 | 6 | 8 |
8 | -0.04 | 251 | 14.10 | 325 | 6 | 159 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.08 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2001.60 | 62 | 10.83 | 3004 | 6 | 6 |
3 | 1602.32 | 24 | 12.45 | 2505 | 6 | 6 |
4 | 1167.68 | 24 | 12.81 | 1978 | 6 | 6 |
5 | 698.84 | 24 | 13.27 | 1349 | 6 | 6 |
6 | 108.48 | 24 | 14.05 | 505 | 6 | 7 |
7 | 58.48 | 24 | 14.19 | 430 | 6 | 7 |
8 | 0.48 | 251 | 14.09 | 323 | 6 | 92 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.96 | 31 | 14.23 | 442 | 6 | 6 |
2 | 978.72 | -1 | 14.23 | 442 | 6 | 6 |
3 | 2006.44 | 62 | 10.79 | 3032 | 6 | 6 |
4 | 1809.56 | 24 | 12.27 | 2772 | 5 | 6 |
5 | 1356.00 | 25 | 12.65 | 2201 | 6 | 6 |
6 | 635.36 | 24 | 13.32 | 1272 | 6 | 6 |
7 | 92.92 | 24 | 14.06 | 482 | 6 | 7 |
8 | 50.48 | 24 | 14.20 | 416 | 6 | 8 |
9 | 0.12 | 251 | 14.08 | 323 | 6 | 88 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.88 | 30 | 14.29 | 442 | 6 | 6 |
2 | 2000.60 | 62 | 10.92 | 3002 | 6 | 6 |
3 | 1788.00 | 25 | 12.28 | 2732 | 6 | 6 |
4 | 1113.60 | 24 | 12.86 | 1893 | 6 | 6 |
5 | 440.64 | 24 | 13.58 | 990 | 6 | 6 |
6 | 94.40 | 24 | 14.08 | 486 | 6 | 7 |
7 | 52.84 | 24 | 14.18 | 422 | 6 | 8 |
8 | -0.00 | 250 | 14.10 | 320 | 6 | 108 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 30 | 14.29 | 461 | 6 | 6 |
2 | 2008.24 | 62 | 10.86 | 3025 | 6 | 6 |
3 | 1809.52 | 25 | 12.24 | 2788 | 6 | 6 |
4 | 1129.28 | 24 | 12.85 | 1914 | 6 | 6 |
5 | 440.92 | 24 | 13.54 | 1009 | 6 | 7 |
6 | 99.12 | 24 | 14.06 | 501 | 6 | 7 |
7 | 49.20 | 24 | 14.20 | 417 | 6 | 8 |
8 | -0.00 | 251 | 14.06 | 328 | 6 | 99 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.32 | 31 | 14.36 | 423 | 6 | 6 |
2 | 979.60 | -1 | 14.36 | 423 | 6 | 6 |
3 | 1019.96 | 1 | 10.86 | 1730 | 6 | 6 |
4 | 2004.08 | 62 | 10.92 | 3012 | 6 | 6 |
5 | 1802.00 | 24 | 12.26 | 2763 | 6 | 6 |
6 | 1127.24 | 24 | 12.84 | 1922 | 6 | 6 |
7 | 447.88 | 24 | 13.57 | 1005 | 6 | 6 |
8 | 109.00 | 24 | 14.05 | 511 | 6 | 7 |
9 | 56.40 | 24 | 14.19 | 420 | 6 | 8 |
10 | 0.08 | 251 | 14.08 | 323 | 6 | 87 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.80 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2007.24 | 62 | 10.93 | 3028 | 6 | 6 |
3 | 1578.64 | 24 | 12.42 | 2497 | 6 | 6 |
4 | 931.12 | 24 | 13.06 | 1645 | 6 | 6 |
5 | 498.56 | 24 | 13.46 | 1086 | 6 | 6 |
6 | 106.64 | 24 | 14.03 | 515 | 6 | 7 |
7 | 25.84 | 24 | 14.20 | 387 | 6 | 8 |
8 | -0.04 | 251 | 14.03 | 324 | 6 | 115 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.28 | 31 | 14.29 | 461 | 6 | 6 |
2 | 2001.92 | 62 | 10.88 | 3029 | 6 | 6 |
3 | 1800.88 | 25 | 12.29 | 2755 | 6 | 6 |
4 | 1141.88 | 24 | 12.84 | 1936 | 6 | 6 |
5 | 467.64 | 24 | 13.52 | 1034 | 6 | 6 |
6 | 102.00 | 24 | 14.05 | 509 | 6 | 7 |
7 | 47.04 | 24 | 14.18 | 416 | 6 | 8 |
8 | 0.08 | 251 | 14.03 | 330 | 6 | 94 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.32 | 31 | 14.29 | 461 | 6 | 6 |
2 | 2004.56 | 62 | 11.01 | 3022 | 6 | 6 |
3 | 1799.20 | 25 | 12.28 | 2743 | 6 | 6 |
4 | 1093.36 | 24 | 12.90 | 1861 | 6 | 6 |
5 | 624.88 | 24 | 13.38 | 1240 | 6 | 6 |
6 | 84.32 | 24 | 14.10 | 468 | 6 | 7 |
7 | 45.56 | 25 | 14.16 | 414 | 6 | 8 |
8 | -0.04 | 251 | 14.04 | 328 | 6 | 95 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 31 | 14.23 | 461 | 6 | 6 |
2 | 2002.24 | 62 | 10.99 | 3003 | 6 | 6 |
3 | 1794.64 | 24 | 12.28 | 2751 | 5 | 6 |
4 | 1107.76 | 24 | 12.87 | 1907 | 6 | 6 |
5 | 435.08 | 24 | 13.55 | 1001 | 6 | 6 |
6 | 98.60 | 24 | 14.07 | 497 | 6 | 7 |
7 | 50.56 | 24 | 14.21 | 413 | 6 | 8 |
8 | 0.04 | 251 | 14.07 | 326 | 6 | 97 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.28 | 31 | 14.29 | 442 | 6 | 6 |
2 | 2004.08 | 62 | 10.98 | 3027 | 6 | 6 |
3 | 1582.92 | 24 | 12.52 | 2476 | 6 | 6 |
4 | 1152.28 | 24 | 12.88 | 1945 | 5 | 6 |
5 | 669.40 | 24 | 13.34 | 1303 | 6 | 6 |
6 | 94.16 | 24 | 14.08 | 491 | 6 | 7 |
7 | 55.84 | 24 | 14.21 | 422 | 6 | 8 |
8 | -0.08 | 251 | 14.09 | 322 | 6 | 101 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 30 | 14.29 | 442 | 6 | 6 |
2 | 1026.80 | 1 | 11.81 | 1769 | 6 | 6 |
3 | 2006.48 | 62 | 11.05 | 3017 | 6 | 6 |
4 | 1789.72 | 24 | 12.33 | 2738 | 5 | 6 |
5 | 1098.36 | 24 | 12.94 | 1861 | 6 | 6 |
6 | 417.44 | 24 | 13.62 | 970 | 6 | 7 |
7 | 95.68 | 24 | 14.07 | 487 | 6 | 7 |
8 | 51.92 | 24 | 14.21 | 415 | 6 | 8 |
9 | 0.04 | 251 | 14.09 | 319 | 6 | 101 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.80 | 31 | 14.29 | 442 | 6 | 6 |
2 | 981.28 | -1 | 14.29 | 442 | 6 | 6 |
3 | 2006.48 | 62 | 11.05 | 3018 | 6 | 6 |
4 | 1792.12 | 24 | 12.31 | 2768 | 6 | 6 |
5 | 1116.80 | 24 | 12.92 | 1889 | 6 | 6 |
6 | 433.32 | 24 | 13.59 | 989 | 6 | 6 |
7 | 95.32 | 24 | 14.09 | 492 | 6 | 7 |
8 | 51.20 | 24 | 14.20 | 422 | 6 | 8 |
9 | 0.04 | 251 | 14.09 | 322 | 6 | 101 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.60 | 31 | 14.36 | 442 | 6 | 6 |
2 | 970.72 | -1 | 14.36 | 442 | 6 | 6 |
3 | 2001.72 | 62 | 11.10 | 2991 | 6 | 6 |
4 | 1577.84 | 25 | 12.46 | 2505 | 6 | 6 |
5 | 941.56 | 24 | 13.09 | 1642 | 6 | 6 |
6 | 294.32 | 24 | 13.80 | 770 | 6 | 6 |
7 | 82.24 | 24 | 14.18 | 457 | 6 | 7 |
8 | 43.56 | 24 | 14.26 | 395 | 6 | 7 |
9 | -0.04 | 250 | 14.13 | 310 | 6 | 181 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.04 | 30 | 14.29 | 442 | 6 | 6 |
2 | 1030.44 | 1 | 12.06 | 1788 | 6 | 6 |
3 | 2008.40 | 62 | 11.06 | 3033 | 6 | 6 |
4 | 1809.76 | 24 | 12.33 | 2770 | 6 | 6 |
5 | 1104.68 | 24 | 12.96 | 1866 | 6 | 6 |
6 | 432.28 | 24 | 13.63 | 974 | 6 | 6 |
7 | 104.52 | 24 | 14.12 | 496 | 6 | 7 |
8 | 58.00 | 24 | 14.19 | 424 | 6 | 7 |
9 | 29.60 | 24 | 14.26 | 372 | 6 | 9 |
10 | 0.04 | 228 | 14.12 | 315 | 6 | 179 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.24 | 30 | 14.29 | 461 | 6 | 6 |
2 | 1028.56 | 1 | 12.06 | 1750 | 6 | 6 |
3 | 2005.52 | 62 | 11.11 | 3012 | 6 | 6 |
4 | 1784.36 | 24 | 12.36 | 2732 | 6 | 6 |
5 | 1126.20 | 24 | 12.91 | 1892 | 6 | 6 |
6 | 448.08 | 24 | 13.59 | 1005 | 6 | 6 |
7 | 110.56 | 24 | 14.06 | 515 | 6 | 7 |
8 | 52.44 | 24 | 14.22 | 414 | 6 | 8 |
9 | 0.04 | 251 | 14.10 | 320 | 6 | 103 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.32 | 31 | 14.36 | 442 | 6 | 6 |
2 | 923.96 | -2 | 14.36 | 442 | 6 | 6 |
3 | 2002.52 | 62 | 11.13 | 2992 | 6 | 6 |
4 | 1784.96 | 24 | 12.37 | 2759 | 6 | 6 |
5 | 1096.40 | 24 | 12.93 | 1876 | 6 | 6 |
6 | 602.32 | 24 | 13.41 | 1220 | 6 | 6 |
7 | 93.04 | 24 | 14.13 | 478 | 6 | 7 |
8 | 46.96 | 24 | 14.21 | 405 | 6 | 8 |
9 | -0.00 | 251 | 14.11 | 321 | 6 | 114 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.96 | 29 | 14.42 | 442 | 6 | 6 |
2 | 1017.68 | 1 | 10.86 | 1788 | 6 | 6 |
3 | 1052.08 | 1 | 12.70 | 1826 | 6 | 6 |
4 | 2002.88 | 62 | 11.12 | 3012 | 6 | 6 |
5 | 1580.12 | 25 | 12.52 | 2486 | 6 | 6 |
6 | 1361.36 | 25 | 12.71 | 2224 | 6 | 6 |
7 | 406.04 | 24 | 13.67 | 949 | 6 | 6 |
8 | 96.64 | 24 | 14.16 | 482 | 6 | 7 |
9 | 51.76 | 24 | 14.25 | 413 | 6 | 8 |
10 | 0.16 | 252 | 14.10 | 319 | 6 | 163 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.36 | 30 | 14.36 | 442 | 6 | 6 |
2 | 981.32 | -1 | 14.36 | 442 | 6 | 6 |
3 | 2002.72 | 62 | 11.16 | 3022 | 6 | 6 |
4 | 1787.52 | 24 | 12.39 | 2742 | 6 | 6 |
5 | 1086.60 | 25 | 12.93 | 1878 | 6 | 6 |
6 | 394.12 | 24 | 13.68 | 936 | 6 | 7 |
7 | 98.88 | 24 | 14.15 | 489 | 6 | 7 |
8 | 53.08 | 24 | 14.23 | 411 | 6 | 8 |
9 | 0.12 | 250 | 14.16 | 314 | 6 | 166 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.24 | 31 | 14.29 | 442 | 6 | 6 |
2 | 949.12 | -1 | 14.29 | 442 | 6 | 6 |
3 | 2008.52 | 62 | 11.12 | 3030 | 6 | 6 |
4 | 1601.32 | 24 | 12.50 | 2541 | 6 | 6 |
5 | 930.80 | 24 | 13.16 | 1637 | 6 | 6 |
6 | 471.92 | 24 | 13.59 | 1047 | 6 | 6 |
7 | 118.44 | 24 | 14.07 | 532 | 6 | 7 |
8 | 54.52 | 24 | 14.28 | 415 | 6 | 8 |
9 | 25.00 | 24 | 14.29 | 363 | 6 | 8 |
10 | 0.04 | 228 | 14.11 | 319 | 6 | 209 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.00 | 30 | 14.29 | 461 | 6 | 6 |
2 | 1008.44 | 2 | 13.14 | 1788 | 6 | 6 |
3 | 2006.00 | 62 | 11.18 | 3030 | 6 | 6 |
4 | 1795.52 | 24 | 12.36 | 2759 | 5 | 6 |
5 | 1091.52 | 24 | 12.98 | 1857 | 6 | 6 |
6 | 408.32 | 24 | 13.66 | 955 | 6 | 6 |
7 | 100.36 | 24 | 14.13 | 497 | 6 | 7 |
8 | 55.44 | 24 | 14.29 | 414 | 6 | 7 |
9 | 0.08 | 251 | 14.15 | 317 | 6 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.80 | 30 | 14.29 | 461 | 6 | 6 |
2 | 978.00 | -1 | 14.29 | 461 | 6 | 6 |
3 | 2008.44 | 62 | 11.18 | 3018 | 6 | 6 |
4 | 1796.08 | 24 | 12.36 | 2793 | 6 | 6 |
5 | 1115.00 | 24 | 12.95 | 1912 | 6 | 6 |
6 | 424.60 | 24 | 13.67 | 968 | 6 | 6 |
7 | 99.40 | 24 | 14.14 | 489 | 6 | 7 |
8 | 54.84 | 24 | 14.23 | 424 | 6 | 7 |
9 | 0.04 | 251 | 14.12 | 322 | 6 | 121 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.20 | 30 | 14.42 | 423 | 6 | 6 |
2 | 2001.04 | 62 | 11.25 | 3000 | 6 | 6 |
3 | 1782.32 | 25 | 12.42 | 2745 | 6 | 6 |
4 | 861.60 | 24 | 13.22 | 1549 | 6 | 6 |
5 | 651.72 | 24 | 13.43 | 1278 | 6 | 7 |
6 | 81.04 | 24 | 14.18 | 462 | 6 | 7 |
7 | 43.44 | 24 | 14.21 | 410 | 6 | 8 |
8 | 0.72 | 251 | 14.05 | 326 | 6 | 163 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.64 | 30 | 14.36 | 442 | 6 | 6 |
2 | 2004.00 | 62 | 11.24 | 3027 | 6 | 6 |
3 | 1572.44 | 24 | 12.57 | 2522 | 6 | 6 |
4 | 1114.76 | 24 | 12.98 | 1905 | 6 | 6 |
5 | 414.68 | 24 | 13.69 | 947 | 6 | 6 |
6 | 111.60 | 24 | 14.12 | 511 | 6 | 7 |
7 | 54.20 | 24 | 14.30 | 409 | 6 | 7 |
8 | -0.00 | 249 | 14.17 | 317 | 6 | 154 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.72 | 30 | 14.36 | 480 | 6 | 6 |
2 | 2001.08 | 62 | 11.27 | 3024 | 6 | 6 |
3 | 1588.56 | 25 | 12.54 | 2541 | 6 | 6 |
4 | 1374.48 | 24 | 12.78 | 2253 | 6 | 6 |
5 | 368.08 | 24 | 13.73 | 901 | 6 | 6 |
6 | 91.84 | 24 | 14.19 | 476 | 6 | 7 |
7 | 48.00 | 24 | 14.31 | 397 | 6 | 7 |
8 | 0.04 | 250 | 14.15 | 316 | 6 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.24 | 30 | 14.36 | 461 | 6 | 6 |
2 | 2002.40 | 62 | 11.30 | 3030 | 6 | 6 |
3 | 1561.80 | 24 | 12.59 | 2487 | 6 | 6 |
4 | 1095.00 | 24 | 13.02 | 1870 | 6 | 6 |
5 | 221.08 | 24 | 13.95 | 688 | 6 | 6 |
6 | 107.96 | 24 | 14.15 | 511 | 6 | 7 |
7 | 55.08 | 24 | 14.25 | 434 | 6 | 8 |
8 | -0.04 | 250 | 14.07 | 333 | 6 | 180 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.60 | 31 | 14.36 | 461 | 6 | 6 |
2 | 973.40 | -1 | 14.36 | 461 | 6 | 6 |
3 | 2002.72 | 62 | 11.34 | 3022 | 6 | 6 |
4 | 1586.24 | 24 | 12.60 | 2507 | 6 | 6 |
5 | 1136.00 | 25 | 13.04 | 1912 | 6 | 6 |
6 | 231.64 | 24 | 13.95 | 692 | 6 | 6 |
7 | 110.80 | 24 | 14.14 | 513 | 6 | 7 |
8 | 27.64 | 24 | 14.36 | 374 | 6 | 8 |
9 | 0.08 | 247 | 14.10 | 323 | 6 | 152 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.52 | 31 | 14.42 | 442 | 6 | 6 |
2 | 2005.32 | 62 | 11.41 | 3012 | 6 | 6 |
3 | 1543.80 | 24 | 12.60 | 2482 | 6 | 6 |
4 | 1106.16 | 24 | 13.07 | 1874 | 6 | 6 |
5 | 386.00 | 24 | 13.71 | 924 | 6 | 7 |
6 | 87.84 | 24 | 14.14 | 488 | 6 | 7 |
7 | 43.48 | 24 | 14.27 | 405 | 6 | 8 |
8 | -0.12 | 250 | 14.10 | 325 | 6 | 204 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.32 | 30 | 14.36 | 461 | 6 | 6 |
2 | 2002.60 | 62 | 11.46 | 3028 | 6 | 6 |
3 | 1788.96 | 25 | 12.46 | 2799 | 6 | 6 |
4 | 1290.08 | 24 | 12.93 | 2147 | 6 | 6 |
5 | 553.24 | 24 | 13.59 | 1161 | 6 | 6 |
6 | 87.60 | 24 | 14.18 | 478 | 6 | 7 |
7 | 50.64 | 24 | 14.28 | 420 | 6 | 7 |
8 | 0.08 | 250 | 14.17 | 323 | 6 | 204 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 30 | 14.42 | 442 | 6 | 6 |
2 | 2006.52 | 62 | 11.50 | 3038 | 6 | 6 |
3 | 1786.56 | 25 | 12.53 | 2766 | 5 | 6 |
4 | 1056.40 | 25 | 13.15 | 1820 | 6 | 6 |
5 | 353.52 | 24 | 13.81 | 868 | 6 | 6 |
6 | 82.72 | 24 | 14.25 | 461 | 6 | 7 |
7 | 43.44 | 24 | 14.32 | 399 | 6 | 7 |
8 | 0.04 | 247 | 14.13 | 325 | 6 | 209 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.88 | 30 | 14.42 | 442 | 6 | 6 |
2 | 2009.48 | 62 | 11.58 | 3037 | 6 | 6 |
3 | 1582.76 | 25 | 12.71 | 2509 | 5 | 6 |
4 | 1103.52 | 25 | 13.11 | 1889 | 6 | 6 |
5 | 185.40 | 25 | 14.05 | 626 | 6 | 7 |
6 | 92.40 | 25 | 14.23 | 486 | 6 | 7 |
7 | 43.28 | 25 | 14.31 | 403 | 6 | 8 |
8 | 0.04 | 242 | 14.12 | 324 | 6 | 185 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 30 | 14.42 | 461 | 6 | 6 |
2 | 2003.36 | 62 | 11.68 | 3028 | 6 | 6 |
3 | 1570.64 | 25 | 12.74 | 2484 | 5 | 6 |
4 | 1092.08 | 25 | 13.14 | 1872 | 6 | 6 |
5 | 190.00 | 25 | 14.05 | 637 | 6 | 7 |
6 | 96.88 | 25 | 14.22 | 499 | 6 | 7 |
7 | 6.12 | 25 | 14.42 | 345 | 6 | 7 |
8 | 0.08 | 239 | 14.12 | 328 | 6 | 149 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.08 | 30 | 14.48 | 442 | 6 | 6 |
2 | 2000.72 | 62 | 11.75 | 3026 | 6 | 6 |
3 | 1582.40 | 25 | 12.76 | 2495 | 6 | 6 |
4 | 909.28 | 25 | 13.30 | 1628 | 6 | 6 |
5 | 217.32 | 25 | 14.01 | 684 | 6 | 7 |
6 | 99.12 | 25 | 14.21 | 499 | 6 | 7 |
7 | 46.04 | 25 | 14.32 | 407 | 6 | 8 |
8 | -0.08 | 242 | 14.13 | 330 | 6 | 247 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.84 | 30 | 14.48 | 461 | 6 | 6 |
2 | 2004.36 | 62 | 11.82 | 3039 | 6 | 6 |
3 | 1536.96 | 25 | 12.80 | 2451 | 6 | 6 |
4 | 847.88 | 25 | 13.40 | 1547 | 6 | 6 |
5 | 196.08 | 25 | 14.05 | 651 | 6 | 7 |
6 | 100.40 | 25 | 14.24 | 503 | 6 | 7 |
7 | 20.40 | 25 | 14.42 | 372 | 6 | 8 |
8 | -0.00 | 239 | 14.16 | 327 | 6 | 169 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.12 | 30 | 14.48 | 442 | 6 | 6 |
2 | 2005.12 | 62 | 11.87 | 3036 | 6 | 6 |
3 | 1583.40 | 25 | 12.84 | 2476 | 6 | 6 |
4 | 894.00 | 25 | 13.35 | 1603 | 6 | 6 |
5 | 201.28 | 25 | 14.06 | 657 | 6 | 6 |
6 | 107.20 | 25 | 14.28 | 497 | 6 | 7 |
7 | 49.12 | 25 | 14.35 | 409 | 6 | 7 |
8 | -0.00 | 239 | 14.20 | 322 | 6 | 173 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.40 | 30 | 14.48 | 442 | 6 | 6 |
2 | 2000.96 | 62 | 11.94 | 3016 | 6 | 6 |
3 | 1359.92 | 25 | 12.99 | 2215 | 6 | 6 |
4 | 907.48 | 25 | 13.36 | 1620 | 6 | 6 |
5 | 212.08 | 25 | 14.08 | 664 | 6 | 7 |
6 | 68.28 | 25 | 14.37 | 426 | 6 | 7 |
7 | 34.96 | 25 | 14.40 | 372 | 6 | 7 |
8 | 0.04 | 236 | 14.20 | 320 | 6 | 189 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.32 | 30 | 14.48 | 461 | 6 | 6 |
2 | 2003.40 | 62 | 11.96 | 3046 | 6 | 6 |
3 | 1571.24 | 25 | 12.87 | 2480 | 6 | 6 |
4 | 884.36 | 25 | 13.36 | 1613 | 6 | 6 |
5 | 196.96 | 25 | 14.12 | 643 | 6 | 6 |
6 | 92.84 | 25 | 14.31 | 476 | 6 | 7 |
7 | 45.28 | 25 | 14.37 | 401 | 6 | 8 |
8 | -0.00 | 239 | 14.19 | 321 | 6 | 232 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.00 | 30 | 14.48 | 461 | 6 | 6 |
2 | 2002.00 | 62 | 11.99 | 3024 | 6 | 6 |
3 | 1558.96 | 25 | 12.89 | 2482 | 6 | 6 |
4 | 856.68 | 25 | 13.43 | 1566 | 6 | 6 |
5 | 185.20 | 25 | 14.12 | 637 | 6 | 7 |
6 | 89.56 | 25 | 14.29 | 484 | 6 | 7 |
7 | 42.32 | 25 | 14.36 | 397 | 6 | 8 |
8 | -0.12 | 239 | 14.18 | 322 | 6 | 244 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.80 | 30 | 14.48 | 461 | 6 | 6 |
2 | 2012.04 | 62 | 12.03 | 3009 | 6 | 6 |
3 | 1553.44 | 25 | 12.87 | 2480 | 6 | 6 |
4 | 873.24 | 25 | 13.42 | 1578 | 6 | 6 |
5 | 196.16 | 25 | 14.13 | 637 | 6 | 7 |
6 | 97.24 | 25 | 14.28 | 482 | 6 | 7 |
7 | 45.32 | 25 | 14.40 | 389 | 6 | 8 |
8 | 0.12 | 236 | 14.20 | 321 | 6 | 171 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.60 | 30 | 14.42 | 500 | 6 | 6 |
2 | 2004.40 | 62 | 12.06 | 3032 | 6 | 6 |
3 | 1574.64 | 25 | 12.89 | 2522 | 5 | 6 |
4 | 873.52 | 25 | 13.42 | 1597 | 6 | 6 |
5 | 190.92 | 25 | 14.16 | 634 | 6 | 7 |
6 | 95.32 | 25 | 14.34 | 482 | 6 | 7 |
7 | 44.08 | 25 | 14.40 | 401 | 6 | 8 |
8 | -0.00 | 236 | 14.21 | 322 | 6 | 221 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 30 | 14.55 | 442 | 6 | 6 |
2 | 2002.64 | 62 | 12.05 | 3024 | 6 | 6 |
3 | 1543.76 | 25 | 12.92 | 2465 | 6 | 6 |
4 | 848.44 | 25 | 13.48 | 1557 | 6 | 6 |
5 | 182.80 | 25 | 14.17 | 626 | 6 | 7 |
6 | 96.92 | 25 | 14.36 | 480 | 6 | 7 |
7 | 47.12 | 25 | 14.42 | 401 | 6 | 7 |
8 | 0.04 | 236 | 14.24 | 315 | 6 | 240 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.48 | 30 | 14.55 | 461 | 6 | 6 |
2 | 2007.88 | 62 | 12.05 | 3036 | 6 | 6 |
3 | 1551.48 | 25 | 12.93 | 2482 | 6 | 6 |
4 | 657.04 | 25 | 13.65 | 1297 | 6 | 6 |
5 | 208.04 | 25 | 14.17 | 661 | 6 | 7 |
6 | 100.00 | 25 | 14.35 | 489 | 6 | 7 |
7 | 46.24 | 25 | 14.41 | 397 | 6 | 8 |
8 | 0.04 | 234 | 14.23 | 318 | 6 | 155 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.92 | 30 | 14.55 | 442 | 6 | 6 |
2 | 2006.60 | 62 | 12.07 | 3041 | 6 | 6 |
3 | 1792.76 | 25 | 12.78 | 2782 | 6 | 6 |
4 | 824.28 | 25 | 13.54 | 1505 | 6 | 6 |
5 | 187.16 | 25 | 14.19 | 634 | 6 | 7 |
6 | 95.24 | 25 | 14.35 | 484 | 6 | 7 |
7 | 19.04 | 25 | 14.45 | 365 | 6 | 7 |
8 | -0.00 | 236 | 14.22 | 321 | 6 | 210 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.00 | 29 | 14.55 | 461 | 6 | 6 |
2 | 1024.48 | 1 | 13.78 | 1826 | 6 | 6 |
3 | 2004.72 | 62 | 11.98 | 3028 | 6 | 6 |
4 | 1784.64 | 25 | 12.81 | 2734 | 6 | 6 |
5 | 1063.44 | 25 | 13.32 | 1839 | 6 | 6 |
6 | 191.44 | 25 | 14.19 | 637 | 6 | 7 |
7 | 97.48 | 25 | 14.34 | 495 | 6 | 7 |
8 | 47.32 | 25 | 14.41 | 405 | 6 | 8 |
9 | 0.04 | 239 | 14.22 | 317 | 6 | 203 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.44 | 29 | 14.48 | 461 | 6 | 6 |
2 | 976.84 | -1 | 14.48 | 461 | 6 | 6 |
3 | 2003.76 | 62 | 12.12 | 3008 | 6 | 6 |
4 | 1336.88 | 25 | 13.12 | 2203 | 6 | 6 |
5 | 694.08 | 25 | 13.66 | 1349 | 6 | 6 |
6 | 142.60 | 25 | 14.28 | 562 | 6 | 6 |
7 | 76.76 | 25 | 14.41 | 447 | 6 | 7 |
8 | 37.84 | 25 | 14.43 | 384 | 6 | 8 |
9 | -0.04 | 234 | 14.23 | 322 | 6 | 196 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.52 | 29 | 14.55 | 461 | 6 | 6 |
2 | 2004.96 | 62 | 12.16 | 3042 | 6 | 6 |
3 | 1518.36 | 25 | 13.04 | 2441 | 5 | 6 |
4 | 637.80 | 25 | 13.71 | 1272 | 6 | 6 |
5 | 192.44 | 25 | 14.19 | 653 | 6 | 7 |
6 | 94.60 | 25 | 14.35 | 492 | 6 | 7 |
7 | 19.32 | 25 | 14.48 | 370 | 6 | 7 |
8 | 0.52 | 234 | 14.19 | 328 | 6 | 158 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.80 | 30 | 14.55 | 461 | 6 | 6 |
2 | 981.92 | -1 | 14.55 | 461 | 6 | 6 |
3 | 1025.60 | 1 | 13.85 | 1788 | 6 | 6 |
4 | 2004.52 | 62 | 12.06 | 3047 | 6 | 6 |
5 | 1364.88 | 25 | 13.12 | 2220 | 6 | 6 |
6 | 909.52 | 25 | 13.48 | 1643 | 6 | 6 |
7 | 145.08 | 25 | 14.27 | 566 | 6 | 6 |
8 | 82.00 | 25 | 14.39 | 470 | 6 | 7 |
9 | 37.68 | 25 | 14.45 | 387 | 6 | 7 |
10 | 0.04 | 236 | 14.23 | 324 | 6 | 246 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.24 | 30 | 14.48 | 461 | 6 | 6 |
2 | 2004.36 | 62 | 12.18 | 3004 | 6 | 6 |
3 | 1332.88 | 25 | 13.20 | 2163 | 6 | 6 |
4 | 879.76 | 25 | 13.52 | 1584 | 6 | 6 |
5 | 169.88 | 25 | 14.24 | 609 | 6 | 7 |
6 | 94.84 | 25 | 14.35 | 484 | 6 | 7 |
7 | 18.60 | 25 | 14.50 | 363 | 6 | 7 |
8 | 0.28 | 233 | 14.19 | 328 | 6 | 174 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.68 | 30 | 14.55 | 461 | 6 | 6 |
2 | 2001.12 | 62 | 12.17 | 3037 | 6 | 6 |
3 | 1335.24 | 25 | 13.18 | 2174 | 6 | 6 |
4 | 881.76 | 25 | 13.56 | 1572 | 6 | 6 |
5 | 188.36 | 25 | 14.22 | 632 | 6 | 7 |
6 | 92.04 | 25 | 14.36 | 476 | 6 | 7 |
7 | 16.36 | 25 | 14.47 | 353 | 6 | 8 |
8 | 0.08 | 234 | 14.19 | 326 | 6 | 179 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 30 | 14.48 | 480 | 6 | 6 |
2 | 978.80 | -1 | 14.48 | 480 | 6 | 6 |
3 | 2001.64 | 62 | 12.18 | 3030 | 6 | 6 |
4 | 1540.88 | 25 | 13.06 | 2449 | 6 | 6 |
5 | 831.48 | 25 | 13.56 | 1538 | 6 | 6 |
6 | 177.56 | 25 | 14.25 | 618 | 6 | 6 |
7 | 92.20 | 25 | 14.39 | 474 | 6 | 7 |
8 | 19.76 | 25 | 14.52 | 359 | 6 | 7 |
9 | 0.04 | 234 | 14.24 | 331 | 6 | 204 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.20 | 30 | 14.48 | 480 | 6 | 6 |
2 | 2006.08 | 62 | 12.20 | 3040 | 6 | 6 |
3 | 1576.04 | 25 | 13.04 | 2493 | 6 | 6 |
4 | 851.80 | 25 | 13.57 | 1543 | 6 | 6 |
5 | 184.28 | 25 | 14.26 | 624 | 6 | 6 |
6 | 94.12 | 25 | 14.38 | 482 | 6 | 7 |
7 | 0.12 | 251 | 14.26 | 328 | 6 | 73 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.40 | 30 | 14.48 | 461 | 6 | 6 |
2 | 2005.48 | 62 | 12.19 | 3032 | 6 | 6 |
3 | 1555.24 | 25 | 13.04 | 2491 | 6 | 6 |
4 | 867.56 | 25 | 13.56 | 1580 | 6 | 6 |
5 | 176.36 | 25 | 14.24 | 634 | 6 | 6 |
6 | 89.28 | 25 | 14.36 | 490 | 6 | 7 |
7 | 5.08 | 25 | 14.55 | 337 | 6 | 7 |
8 | 0.08 | 234 | 14.22 | 326 | 6 | 193 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 29 | 14.61 | 423 | 6 | 6 |
2 | 2002.64 | 62 | 12.17 | 3043 | 6 | 6 |
3 | 1549.88 | 25 | 13.04 | 2443 | 6 | 6 |
4 | 830.52 | 25 | 13.56 | 1524 | 6 | 6 |
5 | 175.40 | 25 | 14.26 | 609 | 6 | 6 |
6 | 90.68 | 25 | 14.39 | 464 | 6 | 7 |
7 | 42.48 | 25 | 14.44 | 387 | 6 | 7 |
8 | -0.00 | 234 | 14.23 | 309 | 6 | 229 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.04 | 29 | 14.61 | 423 | 6 | 6 |
2 | 2002.16 | 62 | 12.14 | 3030 | 6 | 6 |
3 | 1550.04 | 25 | 13.00 | 2457 | 6 | 6 |
4 | 857.76 | 25 | 13.53 | 1545 | 6 | 6 |
5 | 167.20 | 25 | 14.26 | 597 | 6 | 6 |
6 | 83.24 | 25 | 14.40 | 453 | 6 | 7 |
7 | 16.60 | 25 | 14.50 | 342 | 6 | 7 |
8 | -0.04 | 234 | 14.21 | 308 | 6 | 198 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.12 | 29 | 14.55 | 442 | 6 | 6 |
2 | 2003.80 | 62 | 12.11 | 3030 | 6 | 6 |
3 | 1558.28 | 25 | 12.96 | 2480 | 6 | 6 |
4 | 860.96 | 25 | 13.52 | 1553 | 6 | 6 |
5 | 183.16 | 25 | 14.25 | 615 | 6 | 6 |
6 | 90.72 | 25 | 14.38 | 468 | 6 | 7 |
7 | 20.84 | 25 | 14.52 | 349 | 6 | 7 |
8 | 0.08 | 233 | 14.24 | 308 | 6 | 223 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.12 | 28 | 14.55 | 442 | 6 | 6 |
2 | 2001.16 | 62 | 12.04 | 3048 | 6 | 6 |
3 | 1565.96 | 25 | 12.95 | 2476 | 6 | 6 |
4 | 700.00 | 25 | 13.64 | 1349 | 6 | 6 |
5 | 239.76 | 25 | 14.16 | 703 | 6 | 6 |
6 | 109.16 | 25 | 14.35 | 503 | 6 | 7 |
7 | 22.48 | 25 | 14.52 | 357 | 6 | 7 |
8 | -0.00 | 234 | 14.25 | 306 | 6 | 179 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.32 | 29 | 14.55 | 442 | 6 | 6 |
2 | 978.60 | -1 | 14.55 | 442 | 6 | 6 |
3 | 2004.32 | 62 | 12.11 | 3015 | 6 | 6 |
4 | 1337.84 | 25 | 13.10 | 2178 | 6 | 6 |
5 | 882.40 | 25 | 13.48 | 1557 | 6 | 6 |
6 | 178.16 | 25 | 14.24 | 613 | 6 | 6 |
7 | 87.52 | 25 | 14.39 | 463 | 6 | 6 |
8 | 17.08 | 25 | 14.52 | 347 | 6 | 7 |
9 | 0.68 | 234 | 14.20 | 312 | 6 | 163 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.56 | 29 | 14.55 | 442 | 6 | 6 |
2 | 2002.08 | 62 | 12.10 | 3019 | 6 | 6 |
3 | 1325.92 | 25 | 13.12 | 2155 | 6 | 6 |
4 | 902.36 | 25 | 13.50 | 1595 | 6 | 6 |
5 | 207.04 | 25 | 14.21 | 653 | 6 | 6 |
6 | 94.88 | 25 | 14.37 | 470 | 6 | 7 |
7 | 43.80 | 25 | 14.43 | 391 | 6 | 7 |
8 | 0.04 | 234 | 14.23 | 311 | 6 | 196 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 29 | 14.55 | 442 | 6 | 6 |
2 | 2004.00 | 62 | 12.15 | 3018 | 6 | 6 |
3 | 1546.48 | 25 | 13.00 | 2440 | 6 | 6 |
4 | 843.40 | 25 | 13.54 | 1524 | 6 | 6 |
5 | 177.40 | 25 | 14.23 | 613 | 6 | 6 |
6 | 87.44 | 25 | 14.35 | 468 | 6 | 7 |
7 | 41.20 | 25 | 14.43 | 384 | 6 | 8 |
8 | -0.00 | 234 | 14.22 | 309 | 6 | 222 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.72 | 29 | 14.55 | 442 | 6 | 6 |
2 | 2006.12 | 62 | 12.16 | 3047 | 6 | 6 |
3 | 1552.88 | 25 | 12.98 | 2474 | 6 | 6 |
4 | 861.36 | 25 | 13.52 | 1560 | 6 | 6 |
5 | 179.44 | 25 | 14.25 | 615 | 6 | 6 |
6 | 83.84 | 25 | 14.37 | 462 | 6 | 7 |
7 | 38.56 | 25 | 14.44 | 387 | 6 | 7 |
8 | -0.00 | 231 | 14.23 | 309 | 6 | 154 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.52 | 29 | 14.55 | 442 | 6 | 6 |
2 | 2001.24 | 62 | 12.23 | 3029 | 6 | 6 |
3 | 1568.68 | 25 | 13.03 | 2468 | 6 | 6 |
4 | 857.52 | 25 | 13.53 | 1553 | 6 | 6 |
5 | 176.84 | 25 | 14.24 | 603 | 6 | 6 |
6 | 80.08 | 25 | 14.39 | 447 | 6 | 7 |
7 | 17.68 | 25 | 14.53 | 345 | 6 | 7 |
8 | 0.92 | 231 | 14.18 | 311 | 6 | 170 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 29 | 14.48 | 461 | 6 | 6 |
2 | 2003.04 | 62 | 12.28 | 3038 | 6 | 6 |
3 | 1554.56 | 25 | 13.04 | 2472 | 6 | 6 |
4 | 865.48 | 25 | 13.55 | 1566 | 6 | 6 |
5 | 180.36 | 24 | 14.24 | 618 | 6 | 6 |
6 | 87.20 | 24 | 14.38 | 468 | 6 | 7 |
7 | 39.92 | 25 | 14.45 | 384 | 6 | 7 |
8 | 0.04 | 231 | 14.23 | 310 | 6 | 165 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.68 | 29 | 14.61 | 423 | 6 | 6 |
2 | 982.40 | -1 | 14.61 | 423 | 6 | 6 |
3 | 1018.16 | 1 | 14.36 | 1769 | 6 | 6 |
4 | 2004.08 | 62 | 12.31 | 3039 | 6 | 6 |
5 | 1359.08 | 25 | 13.17 | 2213 | 6 | 6 |
6 | 888.96 | 25 | 13.54 | 1586 | 6 | 6 |
7 | 177.40 | 25 | 14.23 | 611 | 6 | 6 |
8 | 84.60 | 24 | 14.40 | 457 | 6 | 7 |
9 | 15.64 | 24 | 14.55 | 345 | 6 | 7 |
10 | 0.04 | 231 | 14.22 | 308 | 6 | 220 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.12 | 29 | 14.61 | 423 | 6 | 6 |
2 | 2002.08 | 62 | 12.35 | 3034 | 6 | 6 |
3 | 1550.84 | 25 | 13.04 | 2464 | 6 | 6 |
4 | 831.92 | 25 | 13.57 | 1517 | 6 | 6 |
5 | 168.40 | 25 | 14.29 | 592 | 6 | 6 |
6 | 85.00 | 25 | 14.42 | 461 | 6 | 7 |
7 | 40.52 | 25 | 14.48 | 384 | 6 | 7 |
8 | -0.04 | 231 | 14.26 | 306 | 6 | 179 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.96 | 29 | 14.61 | 442 | 6 | 6 |
2 | 2002.20 | 62 | 12.41 | 2998 | 6 | 6 |
3 | 1567.20 | 25 | 13.04 | 2501 | 6 | 6 |
4 | 685.08 | 25 | 13.71 | 1314 | 6 | 6 |
5 | 218.64 | 24 | 14.20 | 670 | 6 | 6 |
6 | 99.00 | 25 | 14.42 | 480 | 6 | 7 |
7 | 18.76 | 25 | 14.58 | 339 | 6 | 7 |
8 | 0.08 | 231 | 14.28 | 304 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.60 | 28 | 14.61 | 442 | 6 | 6 |
2 | 2004.64 | 62 | 12.43 | 3032 | 6 | 6 |
3 | 1546.00 | 25 | 13.09 | 2443 | 6 | 6 |
4 | 848.60 | 25 | 13.56 | 1536 | 6 | 6 |
5 | 166.64 | 25 | 14.31 | 583 | 6 | 6 |
6 | 79.20 | 25 | 14.46 | 442 | 6 | 7 |
7 | 15.84 | 25 | 14.59 | 334 | 6 | 7 |
8 | -0.00 | 231 | 14.24 | 306 | 6 | 240 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.48 | 28 | 14.68 | 442 | 6 | 6 |
2 | 2002.36 | 62 | 12.46 | 3034 | 6 | 6 |
3 | 1339.12 | 25 | 13.19 | 2182 | 6 | 6 |
4 | 878.24 | 25 | 13.52 | 1582 | 6 | 6 |
5 | 166.84 | 25 | 14.30 | 587 | 6 | 6 |
6 | 78.72 | 24 | 14.45 | 451 | 6 | 7 |
7 | 0.96 | 251 | 14.25 | 309 | 6 | 101 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.08 | 28 | 14.61 | 442 | 6 | 6 |
2 | 1023.64 | 1 | 14.36 | 1807 | 6 | 6 |
3 | 2001.28 | 62 | 12.49 | 3037 | 6 | 6 |
4 | 1315.88 | 25 | 13.20 | 2130 | 6 | 6 |
5 | 655.76 | 25 | 13.74 | 1270 | 6 | 6 |
6 | 185.16 | 24 | 14.24 | 620 | 6 | 6 |
7 | 53.48 | 24 | 14.54 | 399 | 6 | 7 |
8 | 0.08 | 251 | 14.27 | 303 | 6 | 157 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.04 | 28 | 14.68 | 423 | 6 | 6 |
2 | 2002.08 | 62 | 12.51 | 3032 | 6 | 6 |
3 | 1322.68 | 25 | 13.20 | 2151 | 6 | 6 |
4 | 670.32 | 25 | 13.71 | 1288 | 6 | 6 |
5 | 200.40 | 25 | 14.26 | 635 | 6 | 7 |
6 | 47.84 | 25 | 14.52 | 403 | 6 | 7 |
7 | 22.04 | 25 | 14.49 | 355 | 6 | 8 |
8 | -0.08 | 225 | 14.24 | 308 | 6 | 149 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.76 | 27 | 14.61 | 442 | 6 | 6 |
2 | 2003.20 | 62 | 12.52 | 3042 | 6 | 6 |
3 | 1558.44 | 25 | 13.02 | 2461 | 6 | 6 |
4 | 614.96 | 25 | 13.74 | 1222 | 6 | 6 |
5 | 170.44 | 24 | 14.28 | 595 | 6 | 6 |
6 | 77.72 | 24 | 14.44 | 445 | 6 | 7 |
7 | 0.08 | 251 | 14.24 | 306 | 6 | 186 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.48 | 27 | 14.61 | 423 | 6 | 6 |
2 | 2005.60 | 62 | 12.52 | 3035 | 6 | 6 |
3 | 1322.56 | 25 | 13.16 | 2161 | 6 | 6 |
4 | 849.52 | 25 | 13.50 | 1543 | 6 | 6 |
5 | 169.00 | 25 | 14.29 | 589 | 6 | 7 |
6 | 41.52 | 25 | 14.54 | 389 | 6 | 7 |
7 | 0.04 | 251 | 14.23 | 306 | 6 | 171 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 25 | 14.68 | 442 | 6 | 6 |
2 | 1058.96 | 2 | 14.42 | 1826 | 6 | 6 |
3 | 2002.36 | 62 | 12.50 | 3046 | 6 | 6 |
4 | 1503.36 | 25 | 13.00 | 2401 | 6 | 6 |
5 | 771.92 | 25 | 13.57 | 1428 | 6 | 6 |
6 | 142.24 | 25 | 14.32 | 547 | 6 | 6 |
7 | 65.32 | 25 | 14.46 | 428 | 6 | 7 |
8 | 0.08 | 251 | 14.21 | 306 | 6 | 155 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.20 | 29 | 14.61 | 423 | 6 | 6 |
2 | 878.08 | -4 | 14.61 | 423 | 6 | 6 |
3 | 2007.48 | 62 | 12.46 | 3052 | 6 | 6 |
4 | 1556.20 | 25 | 12.93 | 2484 | 6 | 6 |
5 | 851.84 | 25 | 13.45 | 1547 | 6 | 6 |
6 | 173.24 | 24 | 14.24 | 613 | 6 | 6 |
7 | 45.52 | 24 | 14.51 | 405 | 6 | 6 |
8 | 22.88 | 25 | 14.46 | 357 | 6 | 7 |
9 | -0.04 | 228 | 14.19 | 310 | 6 | 224 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.44 | 27 | 14.55 | 442 | 6 | 6 |
2 | 979.52 | -1 | 14.55 | 442 | 6 | 6 |
3 | 1517.72 | 62 | 12.81 | 2428 | 6 | 6 |
4 | 1101.88 | 25 | 13.21 | 1878 | 6 | 6 |
5 | 407.20 | 25 | 13.89 | 932 | 6 | 6 |
6 | 97.64 | 25 | 14.42 | 478 | 6 | 6 |
7 | 48.96 | 25 | 14.46 | 399 | 6 | 7 |
8 | 0.04 | 244 | 14.18 | 307 | 6 | 219 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.20 | 26 | 14.61 | 423 | 6 | 6 |
2 | 1512.72 | 62 | 12.73 | 2437 | 6 | 6 |
3 | 1296.40 | 25 | 13.06 | 2161 | 6 | 6 |
4 | 575.16 | 25 | 13.64 | 1193 | 6 | 6 |
5 | 135.36 | 25 | 14.28 | 547 | 6 | 6 |
6 | 34.04 | 25 | 14.50 | 370 | 6 | 6 |
7 | -0.00 | 247 | 14.14 | 307 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.76 | 28 | 14.55 | 423 | 6 | 6 |
2 | 919.92 | -2 | 14.55 | 423 | 6 | 6 |
3 | 1512.80 | 62 | 12.63 | 2429 | 6 | 6 |
4 | 1308.64 | 25 | 12.92 | 2186 | 6 | 6 |
5 | 371.92 | 25 | 13.84 | 899 | 6 | 6 |
6 | 96.56 | 25 | 14.35 | 474 | 6 | 6 |
7 | 50.00 | 25 | 14.42 | 389 | 6 | 6 |
8 | 0.12 | 250 | 14.14 | 301 | 6 | 249 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.72 | 28 | 14.61 | 423 | 6 | 6 |
2 | 929.52 | -2 | 14.61 | 423 | 6 | 6 |
3 | 1027.24 | 62 | 12.84 | 1787 | 6 | 6 |
4 | 149.56 | 24 | 14.12 | 568 | 6 | 6 |
5 | 81.76 | 24 | 14.30 | 455 | 6 | 6 |
6 | 0.08 | 251 | 14.11 | 307 | 6 | 60 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 98.44 | 62 | 14.30 | 375 | 200 | 6 |
2 | 116.28 | 25 | 14.53 | 409 | 6 | 6 |
3 | 82.64 | 25 | 14.63 | 372 | 6 | 6 |
4 | 0.20 | 250 | 14.49 | 254 | 6 | 24 |