SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 6002 WMO= 5904318


Cycle 550 GMT 28/ 9/2013 4:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 50.70 300 11.29 387 7 43
2 134.30 79 11.25 441 7 51
3 121.90 1 11.38 404 7 56
4 113.80 40 11.26 432 7 56
5 77.50 31 11.32 408 7 61
6 59.70 31 11.29 400 7 62
7 48.80 31 11.30 394 7 62
8 34.30 31 11.28 388 7 61
9 21.20 31 11.31 366 7 62
10 10.00 31 11.29 364 7 63
11 0.00 31 11.31 360 8 66
12 0.00 500 11.30 334 9 64

Cycle 549 GMT 28/ 9/2013 1:30: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 62.90 299 11.78 396 7 44
2 251.40 37 11.98 524 7 59
3 227.10 2 12.06 535 7 65
4 190.90 40 11.98 524 7 72
5 121.10 31 11.94 472 7 73
6 93.00 31 11.82 458 7 74
7 69.20 31 11.72 430 7 75
8 50.20 31 11.64 420 7 73
9 35.90 31 11.60 408 7 72
10 23.70 31 11.57 386 7 71
11 12.30 31 11.54 386 7 72
12 7.80 500 11.41 354 8 72

Cycle 548 GMT 27/ 9/2013 21:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 60.70 255 12.45 404 7 47
2 253.80 86 12.60 542 7 57
3 122.10 40 13.17 482 7 78
4 75.60 31 12.98 458 7 78
5 57.10 31 12.78 444 7 78
6 41.80 31 12.68 422 7 76
7 26.40 31 12.53 416 7 76
8 15.50 31 12.51 390 7 74
9 4.20 31 12.41 404 8 73
10 -0.40 31 12.43 382 10 66
11 -0.20 500 12.04 352 10 69

Cycle 547 GMT 27/ 9/2013 18: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 52.40 281 13.11 399 7 48
2 247.90 19 13.76 565 7 66
3 179.90 40 13.52 541 7 80
4 113.70 31 13.65 503 7 80
5 85.10 31 13.45 476 7 83
6 61.30 31 13.26 446 7 82
7 42.70 31 13.13 434 7 81
8 28.80 31 13.03 418 7 79
9 15.80 31 12.89 406 7 79
10 4.60 31 12.90 398 8 81
11 -0.30 31 12.85 388 7 76
12 -0.20 500 12.56 359 8 95

Cycle 521 GMT 26/ 9/2013 18:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 57.50 270 13.04 412 7 50
2 253.30 54 13.90 556 7 66
3 133.50 40 14.13 496 7 84
4 84.50 31 14.17 477 7 87
5 59.40 31 14.15 456 7 88
6 40.40 31 14.13 440 7 87
7 25.50 31 14.01 432 7 86
8 16.30 31 13.80 406 7 85
9 4.10 31 13.52 402 8 83
10 -0.40 31 13.41 386 8 81
11 -0.30 500 12.86 361 8 99

Cycle 520 GMT 26/ 9/2013 14:47: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 59.40 265 13.19 418 7 51
2 252.20 49 14.04 553 7 71
3 154.90 40 14.09 518 7 86
4 93.40 31 14.16 485 7 88
5 69.20 31 14.18 474 7 89
6 51.50 31 14.20 448 7 88
7 33.20 31 14.22 438 7 88
8 19.50 31 14.15 412 7 86
9 6.40 31 13.97 410 7 85
10 -0.10 31 13.86 404 7 77
11 -0.20 500 12.98 362 9 96

Cycle 519 GMT 26/ 9/2013 11: 5: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 53.00 277 13.38 416 7 52
2 252.60 32 14.23 574 7 75
3 156.50 40 14.15 524 7 83
4 96.80 31 14.27 481 7 89
5 70.00 31 14.38 458 7 91
6 51.50 31 14.40 466 7 91
7 35.10 31 14.32 444 7 90
8 22.80 31 14.31 430 7 89
9 13.60 31 14.18 420 7 88
10 5.80 31 14.06 410 7 88
11 -0.30 31 13.99 418 8 83
12 -0.20 485 13.03 366 7

Cycle 518 GMT 26/ 9/2013 6:59: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 56.60 231 13.82 409 7 50
2 253.10 90 13.99 547 7 61
3 104.50 40 14.20 483 7 79
4 60.10 31 14.34 454 7 81
5 46.60 31 14.39 448 7 82
6 31.20 31 14.43 434 7 82
7 16.80 31 14.44 420 7 81
8 6.90 31 14.38 408 7 80
9 -0.40 31 14.35 404 7 79
10 -0.50 500 13.20 359 7 95

Cycle 500 GMT 25/ 9/2013 20: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.20 191 13.18 481 7 64
2 504.20 173 13.07 745 7 73
3 196.20 40 14.09 581 7 99
4 81.30 31 14.33 484 7 101
5 54.60 31 14.37 472 7 102
6 36.70 31 14.40 460 7 102
7 23.10 31 14.33 450 7 100
8 14.60 31 14.28 440 7 100
9 4.00 31 14.21 428 8 97
10 -0.70 31 14.22 424 7 94
11 -0.50 482 13.08 379 8

Cycle 499 GMT 25/ 9/2013 16: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.40 61 14.13 504 7 59
2 3001.10 83 11.53 2599 6 105
3 2670.30 43 12.19 2381 6 114
4 1916.50 40 12.48 1853 6 119
5 1827.70 31 13.04 1771 7 127
6 1763.80 31 13.16 1721 8 129
7 1683.20 31 13.26 1658 9 130
8 1588.50 31 13.26 1596 9 131
9 1397.30 31 13.38 1453 7 129
10 978.30 31 13.61 1140 6 126
11 867.20 31 13.74 1061 6 127
12 755.10 31 13.82 970 6 128
13 624.80 31 13.90 884 7 129
14 497.40 31 13.99 791 7 130
15 363.30 31 14.07 692 7 130
16 227.90 31 14.14 597 7 127
17 39.90 31 14.25 464 7 120
18 20.90 31 14.32 430 8 120
19 9.10 31 14.26 422 8 120
20 -0.90 31 14.13 428 9 111
21 -0.80 416 12.99 398 8 219

Cycle 498 GMT 24/ 9/2013 6:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.30 61 14.18 509 7 61
2 3001.80 99 11.36 2604 6 107
3 2633.10 40 12.30 2364 6 114
4 1797.30 40 11.61 1806 6 110
5 1718.90 31 12.87 1791 7 126
6 1647.70 31 13.11 1723 9 131
7 1564.50 31 13.27 1616 8 129
8 1478.60 31 13.34 1545 8 132
9 1177.40 31 13.49 1358 6 128
10 964.00 31 13.64 1190 6 128
11 853.70 31 13.73 1102 6 129
12 728.80 31 13.83 987 7 130
13 606.90 31 13.87 938 7 130
14 478.70 31 14.03 793 7 129
15 353.20 31 14.07 696 7 129
16 212.70 31 14.16 585 7 127
17 88.50 31 14.28 507 7 124
18 16.90 31 14.36 450 7 119
19 6.00 31 14.28 444 8 120
20 -1.20 31 14.24 440 7 119
21 -1.10 405 13.06 399 12 212

Cycle 497 GMT 20/ 9/2013 9:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.90 61 14.21 510 7 60
2 3001.70 85 11.34 2586 6 94
3 2688.30 45 12.19 2383 6 113
4 1934.20 40 11.36 1835 6 108
5 1833.70 31 12.90 1797 7 126
6 1759.30 31 13.19 1727 8 129
7 1666.90 31 13.21 1680 9 128
8 1577.00 31 13.34 1608 9 130
9 1482.30 31 13.37 1543 8 132
10 978.20 31 13.69 1174 6 129
11 880.40 31 13.76 1098 6 129
12 767.10 31 13.83 1025 6 130
13 652.80 31 13.92 950 7 130
14 520.30 31 13.98 844 7 130
15 389.60 31 14.09 761 7 130
16 245.80 31 14.17 654 7 129
17 46.70 31 14.26 525 7 122
18 21.30 31 14.30 501 8 121
19 -1.00 31 14.37 454 8 117
20 -0.90 450 13.11 405 8 226

Cycle 496 GMT 16/ 9/2013 12:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.60 61 14.22 508 7 61
2 3002.70 99 11.16 2605 6 100
3 2655.90 43 12.29 2367 6 114
4 1830.20 40 11.26 1767 6 107
5 1741.70 31 12.96 1727 7 126
6 1664.20 31 13.18 1680 8 130
7 1577.10 31 13.35 1588 8 132
8 1494.30 31 13.40 1543 8 132
9 1191.00 31 13.63 1309 7 131
10 983.50 31 13.73 1166 6 127
11 879.70 31 13.75 1100 6 129
12 762.00 31 13.87 1001 6 131
13 645.80 31 13.94 918 7 131
14 513.60 31 13.99 828 7 131
15 377.00 31 14.10 725 7 131
16 99.30 31 14.24 541 7 124
17 45.60 31 14.33 490 7 123
18 18.80 31 14.33 478 8 122
19 -1.70 31 14.33 479 8 116
20 -1.60 442 13.09 414 8

Cycle 495 GMT 12/ 9/2013 15:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.80 61 14.23 500 7 61
2 3000.80 96 11.25 2567 6 107
3 2660.50 43 12.33 2360 6 112
4 1795.90 40 11.14 1761 6 108
5 1707.80 31 13.13 1711 7 127
6 1644.50 31 13.31 1642 8 131
7 1566.60 31 13.37 1606 8 133
8 1479.80 31 13.45 1537 8 131
9 1188.80 31 13.61 1322 7 130
10 969.30 31 13.79 1142 6 128
11 857.10 31 13.80 1078 6 129
12 754.40 31 13.86 1001 7 130
13 630.40 31 13.97 910 7 131
14 495.30 31 14.03 813 7 131
15 353.90 31 14.10 717 7 131
16 93.00 31 14.30 527 7 125
17 39.80 31 14.28 489 7 123
18 17.40 31 14.31 478 8 122
19 3.30 31 14.29 452 8 122
20 -1.60 31 14.24 458 7 120
21 -1.30 403 13.14 399 10 193

Cycle 494 GMT 8/ 9/2013 18:30: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.10 61 14.19 505 7 62
2 3001.10 85 11.14 2586 6 101
3 2700.50 46 12.23 2393 6 105
4 1921.50 40 10.91 1840 6 104
5 1832.40 31 12.92 1805 7 124
6 1765.60 31 13.18 1741 8 130
7 1690.50 31 13.30 1680 8 131
8 1611.70 31 13.38 1600 8 133
9 1414.70 31 13.46 1483 7 132
10 1325.80 31 13.52 1398 7 130
11 992.00 31 13.73 1175 6 128
12 871.80 31 13.82 1090 6 131
13 747.90 31 13.82 1001 7 130
14 610.60 31 13.97 874 7 131
15 471.10 31 14.02 779 7 132
16 328.30 31 14.13 668 7 130
17 74.20 31 14.25 507 7 125
18 -0.70 31 14.31 448 10 120
19 -1.60 487 13.14 401 9 240

Cycle 493 GMT 4/ 9/2013 21:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.90 61 14.19 478 7 66
2 3000.80 91 11.15 2556 6 105
3 2673.70 44 12.33 2380 6 114
4 1880.30 40 10.84 1806 6 103
5 1773.80 31 12.98 1747 7 126
6 1717.70 31 13.20 1698 8 131
7 1638.30 31 13.35 1624 8 132
8 1353.10 31 13.52 1426 7 134
9 1259.50 31 13.53 1372 7 132
10 950.80 31 13.75 1146 6 128
11 846.40 31 13.82 1068 6 130
12 736.10 31 13.85 985 6 131
13 612.40 31 13.93 894 7 131
14 495.10 31 13.98 819 7 130
15 354.90 31 14.11 696 7 132
16 212.20 31 14.13 610 7 128
17 38.20 31 14.25 491 7 123
18 18.50 31 14.26 470 8 124
19 4.30 31 14.20 463 8 122
20 -1.90 31 14.24 452 7 121
21 -1.70 413 13.11 413 9 241

Cycle 492 GMT 1/ 9/2013 0:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.10 61 14.19 486 7 67
2 3001.40 96 11.15 2558 6 104
3 2664.00 43 12.38 2355 6 112
4 1844.30 40 10.93 1768 6 104
5 1751.50 31 12.97 1739 7 125
6 1694.90 31 13.25 1658 8 132
7 1613.50 31 13.35 1598 8 133
8 1423.80 31 13.52 1456 8 132
9 1329.70 31 13.52 1412 7 130
10 1136.40 31 13.68 1259 6 127
11 919.70 31 13.77 1104 6 129
12 796.30 31 13.85 1017 6 131
13 661.20 31 13.90 918 7 131
14 535.60 31 13.98 826 7 131
15 259.00 31 14.08 658 7 130
16 119.30 31 14.17 545 7 127
17 51.50 31 14.28 474 7 125
18 6.20 31 14.28 448 7 123
19 -1.70 31 14.25 438 6 122
20 -1.60 440 13.19 394 9 249

Cycle 491 GMT 28/ 8/2013 3:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.90 61 14.13 493 7 68
2 3002.10 104 11.11 2573 6 105
3 2639.00 42 12.43 2325 6 114
4 1764.10 40 10.89 1707 6 104
5 1666.40 31 13.06 1644 7 128
6 1602.80 31 13.35 1586 8 132
7 1513.30 31 13.44 1515 8 132
8 1425.00 31 13.43 1469 8 131
9 1044.60 31 13.69 1182 6 130
10 941.40 31 13.76 1102 6 127
11 826.40 31 13.80 1031 6 129
12 716.30 31 13.87 940 6 130
13 598.00 31 13.97 858 7 130
14 465.90 31 14.00 755 7 129
15 341.50 31 14.10 674 7 131
16 82.60 31 14.21 503 7 125
17 39.40 31 14.24 464 7 124
18 16.00 31 14.25 442 8 124
19 0.50 458 13.34 388 8 219

Cycle 490 GMT 24/ 8/2013 7: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.70 61 14.18 483 7 69
2 3001.60 83 11.20 2557 6 105
3 2706.30 46 12.35 2368 6 113
4 1918.60 40 10.60 1807 6 98
5 1820.30 31 12.87 1769 7 126
6 1762.50 31 13.22 1713 8 129
7 1692.70 31 13.27 1658 8 131
8 1603.90 31 13.37 1616 8 132
9 1203.40 31 13.59 1314 7 131
10 1116.90 31 13.68 1239 7 131
11 903.50 31 13.75 1086 6 129
12 793.40 31 13.77 1001 6 129
13 669.10 31 13.91 908 7 131
14 541.50 31 13.98 816 7 131
15 405.60 31 14.06 729 7 131
16 264.00 31 14.07 636 7 129
17 50.50 31 14.22 476 7 125
18 21.30 31 14.21 458 7 125
19 -1.60 31 14.28 446 8 122
20 -1.60 445 13.23 396 9 252

Cycle 489 GMT 20/ 8/2013 9:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.10 61 14.15 490 7 69
2 3002.20 107 11.20 2559 6 104
3 2628.20 40 12.57 2289 6 116
4 1745.20 40 10.77 1693 6 101
5 1650.20 31 13.09 1642 7 129
6 1597.00 31 13.35 1576 8 132
7 1512.10 31 13.40 1523 8 131
8 1418.70 31 13.48 1455 8 128
9 1328.50 31 13.48 1402 7 131
10 894.70 31 13.77 1088 6 129
11 781.60 31 13.80 1017 6 131
12 672.00 31 13.88 942 7 131
13 543.00 31 13.90 842 7 131
14 424.60 31 14.05 731 7 132
15 289.30 31 14.08 640 7 131
16 150.00 31 14.11 543 7 128
17 25.80 31 14.21 466 7 124
18 -1.30 31 14.24 464 8 123
19 -1.40 456 13.16 415 8 194

Cycle 488 GMT 16/ 8/2013 13:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.30 61 14.13 477 7 70
2 3001.20 115 11.13 2558 6 108
3 2606.60 39 12.57 2313 7 116
4 1659.20 40 10.83 1642 6 104
5 1547.90 31 13.16 1582 7 129
6 1486.80 31 13.36 1553 8 134
7 1405.20 31 13.46 1463 8 134
8 1315.00 31 13.46 1428 7 132
9 1223.50 31 13.58 1318 7 130
10 997.60 31 13.73 1132 6 129
11 884.00 31 13.79 1045 6 129
12 756.60 31 13.86 960 7 130
13 633.00 31 13.92 866 7 131
14 356.40 31 14.08 658 7 130
15 217.20 31 14.10 574 7 129
16 87.60 31 14.18 480 7 126
17 40.70 31 14.25 446 7 124
18 0.90 472 13.51 380 8 198

Cycle 487 GMT 12/ 8/2013 17: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.80 61 14.13 479 7 73
2 3001.80 57 11.39 2537 6 102
3 2765.20 5 13.29 2475 6 114
4 2623.40 40 10.17 2295 6 93
5 2516.10 31 12.61 2245 7 119
6 2390.60 31 12.88 2162 8 125
7 1979.50 31 13.14 1860 7 131
8 1909.90 31 13.20 1804 8 133
9 1818.20 31 13.23 1723 9 130
10 1626.40 31 13.42 1581 8 134
11 1531.40 31 13.42 1519 8 130
12 1017.40 31 13.71 1148 7 135
13 915.30 31 13.76 1070 7 134
14 808.60 31 13.82 993 8 135
15 692.60 31 13.87 906 8 135
16 562.50 31 13.93 806 8 133
17 424.00 31 14.02 708 6 129
18 280.70 31 14.13 610 7 131
19 23.90 31 14.23 446 7 124
20 11.20 31 14.23 420 8 125
21 -1.20 31 14.25 412 8 124
22 -1.30 434 13.47 378 11 210

Cycle 486 GMT 9/ 8/2013 16:56: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.50 61 14.15 470 7 73
2 3001.70 38 11.62 2545 6 98
3 2869.60 11 13.12 2495 6 122
4 2720.00 40 9.99 2361 6 91
5 2636.40 31 12.53 2330 6 117
6 2588.90 31 12.83 2265 8 120
7 2057.20 31 13.11 1906 7 129
8 1990.20 31 13.23 1840 8 128
9 1909.70 31 13.20 1795 9 132
10 1826.00 31 13.21 1737 9 132
11 1516.20 31 13.47 1509 8 133
12 1213.10 31 13.60 1289 7 135
13 994.30 31 13.73 1124 7 134
14 886.70 31 13.74 1051 8 135
15 766.70 31 13.81 958 8 135
16 640.60 31 13.89 884 8 136
17 508.40 31 13.94 809 8 128
18 227.80 31 14.10 581 6 128
19 92.30 31 14.16 485 7 127
20 16.20 31 14.26 428 7 125
21 2.00 31 14.22 424 8 124
22 -1.10 31 14.28 418 8 123
23 -0.80 413 13.55 380 8 206

Cycle 485 GMT 6/ 8/2013 15:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.30 61 14.17 464 7 72
2 3002.10 57 11.40 2535 6 103
3 2794.50 6 13.45 2380 6 125
4 2606.00 40 10.12 2268 6 93
5 2491.40 31 12.71 2208 7 120
6 2439.50 31 12.96 2136 8 125
7 2388.30 31 12.99 2114 8 126
8 1977.70 31 13.23 1824 8 130
9 1886.30 31 13.17 1781 9 133
10 1677.60 31 13.35 1608 8 132
11 1590.30 31 13.41 1545 8 130
12 1163.10 31 13.61 1249 7 133
13 950.10 31 13.75 1078 7 134
14 834.30 31 13.79 997 8 135
15 714.50 31 13.87 896 8 135
16 577.50 31 13.94 805 8 134
17 446.10 31 14.01 712 6 128
18 157.90 31 14.21 517 7 128
19 70.00 31 14.24 450 7 126
20 -0.80 31 14.26 416 8 124
21 -0.70 464 13.57 371 9 196

Cycle 484 GMT 3/ 8/2013 16: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.40 61 14.13 487 7 72
2 3001.20 29 11.76 2551 6 87
3 2947.40 17 12.88 2540 6 113
4 2763.50 40 10.54 2390 6 90
5 2669.40 31 12.71 2324 7 120
6 2550.00 31 12.86 2251 7 123
7 1985.00 31 13.10 1854 7 126
8 1925.40 31 13.18 1791 8 133
9 1840.60 31 13.27 1735 9 132
10 1750.50 31 13.26 1662 9 135
11 1660.50 31 13.38 1586 8 134
12 1048.30 31 13.70 1162 7 135
13 949.40 31 13.71 1085 7 135
14 838.00 31 13.78 1017 8 136
15 715.00 31 13.79 956 8 135
16 587.30 31 13.93 829 8 136
17 447.60 31 14.00 749 8 136
18 306.50 31 14.04 614 8 133
19 71.90 31 14.22 436 6 122
20 34.90 31 14.26 416 7 122
21 -0.90 31 14.34 390 8 121
22 -0.90 434 13.74 357 8 217

Cycle 483 GMT 1/ 8/2013 14:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 61 14.15 465 7 71
2 3001.40 37 11.72 2537 6 91
3 2872.60 11 13.11 2509 6 111
4 2742.40 40 10.50 2372 6 97
5 2640.50 31 12.76 2295 7 112
6 2518.20 31 12.94 2205 7 124
7 2252.70 31 13.06 2027 7 127
8 1981.20 31 13.15 1840 8 129
9 1893.70 31 13.21 1787 8 131
10 1799.70 31 13.28 1701 9 131
11 1706.10 31 13.30 1644 8 133
12 1282.90 31 13.57 1328 7 134
13 955.70 31 13.70 1098 7 134
14 833.00 31 13.75 1013 7 133
15 712.40 31 13.86 900 8 135
16 585.90 31 13.96 809 8 135
17 443.70 31 14.01 731 8 134
18 164.80 31 14.13 533 7 129
19 74.80 31 14.24 458 6 119
20 31.90 31 14.25 416 7 119
21 0.10 31 14.27 400 10 117
22 -0.90 432 13.81 355 9 216

Cycle 482 GMT 30/ 7/2013 13:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.80 61 14.15 459 7 73
2 3001.80 50 11.53 2527 6 97
3 2810.00 8 13.35 2422 6 125
4 2650.90 40 10.59 2312 6 97
5 2563.40 31 12.83 2245 7 116
6 2504.00 31 12.92 2195 8 124
7 1956.00 31 13.15 1816 7 130
8 1885.10 31 13.24 1747 8 133
9 1799.50 31 13.23 1686 9 134
10 1704.30 31 13.30 1626 8 131
11 1421.70 31 13.52 1420 7 133
12 1010.60 31 13.66 1116 7 133
13 903.10 31 13.74 1041 7 134
14 788.00 31 13.80 957 8 134
15 663.70 31 13.90 864 8 135
16 529.90 31 13.95 767 8 134
17 390.90 31 14.04 674 8 133
18 109.60 31 14.17 475 6 123
19 48.80 31 14.26 422 7 121
20 21.30 31 14.32 416 7 121
21 -0.90 31 14.28 402 7 121
22 -0.80 419 13.79 364 8 197

Cycle 481 GMT 28/ 7/2013 13:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.90 61 14.15 507 7 71
2 3000.30 33 11.79 2550 6 103
3 2893.10 13 13.11 2523 6 114
4 2741.00 40 10.54 2380 6 96
5 2658.80 31 12.71 2352 7 121
6 2412.80 31 12.93 2183 7 126
7 1987.80 31 13.08 1874 7 129
8 1925.10 31 13.10 1842 8 129
9 1846.70 31 13.18 1771 9 134
10 1758.00 31 13.28 1690 8 132
11 1368.00 31 13.44 1412 7 132
12 967.30 31 13.73 1087 7 134
13 865.00 31 13.77 999 7 135
14 746.80 31 13.77 936 8 134
15 619.60 31 13.89 830 8 135
16 488.90 31 13.89 753 7 133
17 355.80 31 14.09 634 6 129
18 217.00 31 14.14 543 7 127
19 96.70 31 14.22 468 7 125
20 41.20 31 14.29 408 7 123
21 17.00 31 14.29 400 8 123
22 -0.90 31 14.36 398 7 119
23 -0.80 391 13.83 366 8 194

Cycle 480 GMT 26/ 7/2013 12: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.40 61 14.19 446 7 71
2 3001.90 48 11.57 2502 6 94
3 2815.70 8 13.40 2398 6 126
4 2662.20 40 10.65 2286 6 98
5 2579.10 31 12.77 2247 7 120
6 2253.60 31 13.04 2019 7 127
7 2070.80 31 13.18 1850 7 126
8 1929.80 31 13.23 1765 8 132
9 1850.40 31 13.25 1709 9 131
10 1658.40 31 13.40 1572 8 133
11 1164.50 31 13.59 1221 7 134
12 968.40 31 13.70 1073 7 134
13 865.20 31 13.74 1001 7 134
14 742.40 31 13.85 910 8 135
15 626.30 31 13.89 860 8 136
16 496.90 31 13.92 779 8 135
17 358.70 31 14.02 672 7 128
18 222.30 31 14.10 545 6 126
19 97.50 31 14.25 456 7 124
20 42.10 31 14.32 412 7 122
21 0.60 31 14.32 382 8 120
22 -0.70 413 13.87 361 8 195

Cycle 479 GMT 24/ 7/2013 11:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.60 61 14.17 440 7 71
2 3003.20 61 11.49 2498 6 95
3 2873.40 11 13.32 2437 6 118
4 2613.30 40 12.54 2228 6 115
5 2440.40 31 13.01 2090 7 124
6 2316.30 31 13.05 2023 8 126
7 1940.10 31 13.22 1755 7 131
8 1861.50 31 13.27 1692 8 133
9 1773.00 31 13.29 1646 8 134
10 1379.60 31 13.49 1366 7 133
11 1079.70 31 13.67 1130 7 135
12 978.30 31 13.72 1047 7 135
13 848.20 31 13.79 950 7 135
14 738.60 31 13.81 884 7 131
15 596.70 31 13.92 783 6 129
16 465.00 31 13.95 704 6 131
17 330.00 31 14.11 585 7 130
18 187.20 31 14.14 505 7 128
19 12.20 31 14.33 374 7 120
20 -1.00 31 14.33 345 7 121
21 -0.90 421 14.04 319 9 200

Cycle 478 GMT 23/ 7/2013 12:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.50 61 14.19 442 7 71
2 3000.70 54 11.57 2490 6 99
3 2874.20 11 13.27 2466 6 117
4 2655.30 40 12.49 2279 6 110
5 2529.70 31 12.98 2158 7 123
6 2207.80 31 13.09 1944 7 124
7 1934.70 31 13.22 1737 7 130
8 1860.90 31 13.28 1672 8 133
9 1773.60 31 13.31 1632 8 133
10 1380.10 31 13.51 1360 7 135
11 1086.20 31 13.63 1152 7 135
12 984.50 31 13.73 1061 7 132
13 879.60 31 13.78 985 7 134
14 761.00 31 13.87 906 6 127
15 633.60 31 13.90 817 6 129
16 501.80 31 13.98 715 6 130
17 363.30 31 14.02 622 7 131
18 93.40 31 14.23 422 7 124
19 38.90 31 14.29 394 7 122
20 16.10 31 14.35 368 7 123
21 1.00 424 14.08 317 9 194

Cycle 477 GMT 22/ 7/2013 13:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.30 61 14.18 436 7 72
2 3000.70 62 11.51 2479 6 98
3 2851.80 10 13.32 2418 6 121
4 2621.20 40 12.56 2243 6 115
5 2438.10 31 13.01 2079 7 124
6 2129.00 31 13.14 1886 7 118
7 1994.90 31 13.16 1795 8 131
8 1913.80 31 13.18 1759 8 132
9 1819.70 31 13.27 1682 8 133
10 1415.30 31 13.50 1390 7 135
11 916.80 31 13.71 1063 6 132
12 817.00 31 13.71 1021 6 131
13 705.20 31 13.84 904 6 130
14 591.40 31 13.88 832 6 130
15 467.90 31 13.96 757 6 132
16 338.00 31 14.04 648 7 129
17 201.50 31 14.15 545 7 128
18 86.10 31 14.25 444 7 123
19 35.60 31 14.33 392 7 122
20 -0.90 451 14.02 331 7 217

Cycle 476 GMT 21/ 7/2013 13:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 61 14.18 464 7 72
2 3000.40 42 11.75 2495 6 102
3 2909.10 14 13.23 2499 6 117
4 2690.60 40 12.49 2291 6 111
5 2597.70 31 12.88 2243 7 115
6 2394.30 31 13.01 2061 7 125
7 1981.60 31 13.16 1797 7 130
8 1902.10 31 13.20 1737 8 130
9 1816.90 31 13.28 1664 8 133
10 1625.20 31 13.43 1507 8 134
11 1236.80 31 13.61 1239 7 132
12 934.10 31 13.72 1017 6 130
13 821.60 31 13.80 930 6 130
14 707.50 31 13.89 852 6 128
15 586.30 31 13.94 769 6 131
16 459.70 31 14.00 690 7 131
17 323.40 31 14.05 610 7 131
18 187.10 31 14.20 495 7 126
19 82.50 31 14.22 420 7 123
20 33.30 31 14.30 404 7 121
21 -0.80 31 14.31 374 7 121
22 -0.70 408 13.99 331 8 228

Cycle 475 GMT 20/ 7/2013 14:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.00 61 14.21 442 7 72
2 3001.60 49 11.66 2510 6 101
3 2901.00 14 13.21 2495 6 112
4 2671.80 40 12.49 2301 6 114
5 2554.40 31 12.90 2217 7 122
6 2299.80 31 13.04 2007 7 124
7 1940.90 31 13.19 1763 7 130
8 1865.40 31 13.25 1697 8 132
9 1781.10 31 13.26 1656 8 133
10 1691.70 31 13.35 1578 8 132
11 1283.70 31 13.55 1285 7 129
12 977.90 31 13.67 1072 6 129
13 861.60 31 13.81 970 6 129
14 740.80 31 13.86 898 6 130
15 613.20 31 13.91 791 6 131
16 479.20 31 14.02 694 7 132
17 337.70 31 14.11 599 7 130
18 200.70 31 14.16 495 7 127
19 83.90 31 14.29 414 7 124
20 34.20 31 14.35 366 7 121
21 -0.90 31 14.37 343 8 118
22 -0.60 398 14.11 316 9 190

Cycle 474 GMT 19/ 7/2013 15: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.60 17 14.20 458 7 56
2 4000.50 24 11.49 3233 6 80
3 3906.90 14 12.86 3190 6 106
4 3701.10 40 11.99 3017 6 99
5 3585.50 31 12.45 2926 6 103
6 3335.50 31 12.55 2751 6 104
7 3007.00 31 12.70 2531 6 108
8 2614.20 31 12.88 2237 7 122
9 2286.90 31 13.03 2013 7 128
10 2019.70 31 13.16 1834 7 123
11 1941.90 31 13.18 1761 8 132
12 1759.90 31 13.29 1632 8 128
13 1676.10 31 13.34 1581 8 134
14 1376.00 31 13.52 1354 7 132
15 948.30 31 13.66 1039 6 130
16 833.50 31 13.80 950 6 131
17 718.50 31 13.81 892 6 130
18 584.80 31 13.92 803 6 131
19 457.20 31 14.00 700 7 131
20 315.70 31 14.06 597 7 131
21 172.20 31 14.17 499 7 127
22 28.60 31 14.19 410 7 121
23 -0.80 31 14.32 364 7 113
24 -0.60 421 14.02 323 8 156

Cycle 473 GMT 18/ 7/2013 5:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.70 17 14.30 489 7 48
2 4001.30 28 11.79 3291 6 88
3 3920.50 14 12.82 3269 6 103
4 3693.70 40 11.97 3063 6 98
5 3575.60 31 12.41 2977 6 104
6 3451.10 31 12.46 2900 6 89
7 2899.40 31 12.63 2525 6 114
8 2506.00 31 12.89 2209 7 121
9 2322.50 31 13.00 2074 7 126
10 1939.30 31 13.19 1795 7 130
11 1855.40 31 13.23 1739 8 129
12 1771.20 31 13.29 1692 8 133
13 1367.10 31 13.44 1394 7 133
14 1065.80 31 13.61 1166 6 130
15 958.60 31 13.64 1100 6 131
16 847.20 31 13.71 1047 6 130
17 729.90 31 13.80 983 6 131
18 596.80 31 13.89 846 6 132
19 469.50 31 13.97 733 7 133
20 331.90 31 14.11 618 7 131
21 85.10 31 14.20 448 7 123
22 35.30 31 14.27 420 7 122
23 15.30 31 14.29 404 7 121
24 1.50 31 14.37 374 8 124
25 -0.40 391 13.94 339 11 179

Cycle 472 GMT 16/ 7/2013 20:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.60 230 14.08 449 7 70
2 255.80 64 14.10 564 7 78
3 172.40 40 14.17 504 7 91
4 111.20 31 14.22 470 7 94
5 82.60 31 14.26 458 7 92
6 57.40 31 14.30 430 7 94
7 34.40 31 14.31 420 7 93
8 20.50 31 14.30 416 7 94
9 9.20 31 14.35 416 7 93
10 -0.50 31 14.29 398 7 97
11 -0.50 477 14.21 371 9 234

Cycle 471 GMT 16/ 7/2013 17:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.40 274 14.01 458 7 70
2 278.20 40 13.89 686 7 101
3 175.70 31 14.18 547 7 103
4 135.40 31 14.21 491 7 104
5 93.50 31 14.22 472 7 102
6 62.50 31 14.32 438 7 103
7 39.10 31 14.28 426 7 102
8 21.70 31 14.29 418 7 101
9 10.40 31 14.32 394 7 100
10 -0.50 31 14.30 396 8 101
11 -0.40 469 14.08 369 8 244

Cycle 470 GMT 16/ 7/2013 10:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.10 191 13.96 454 7 76
2 503.20 128 13.59 714 7 85
3 246.30 40 14.04 591 7 103
4 125.30 31 14.18 497 7 103
5 90.90 31 14.22 462 7 104
6 57.60 31 14.30 428 7 103
7 33.20 31 14.35 414 7 102
8 18.10 31 14.30 414 7 101
9 5.50 31 14.28 406 7 99
10 -0.50 31 14.33 396 7 97
11 -0.40 456 14.11 361 8 189

Cycle 469 GMT 16/ 7/2013 6:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.60 120 14.10 450 7 75
2 1502.60 140 12.22 1424 6 104
3 786.60 40 13.66 949 6 125
4 666.70 31 13.85 856 6 126
5 589.30 31 13.89 793 6 126
6 508.30 31 13.99 737 6 122
7 410.10 31 14.05 662 6 123
8 300.50 31 14.08 590 6 124
9 188.50 31 14.15 527 7 123
10 100.90 31 14.20 450 7 120
11 54.10 31 14.25 414 7 117
12 23.40 31 14.27 400 7 117
13 9.80 31 14.29 382 8 117
14 -0.70 31 14.28 410 8 111
15 -0.70 424 13.78 361 9 203

Cycle 468 GMT 15/ 7/2013 17:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.00 120 14.09 447 7 75
2 1503.70 96 12.52 1421 6 104
3 1282.30 6 13.89 1332 7 126
4 1106.30 40 13.39 1185 6 123
5 985.60 31 13.64 1100 7 128
6 919.40 31 13.62 1108 7 128
7 831.50 31 13.74 1025 6 126
8 730.80 31 13.85 918 6 125
9 630.60 31 13.87 856 6 126
10 514.50 31 13.93 747 6 126
11 395.40 31 14.03 660 7 127
12 261.70 31 14.15 567 7 126
13 133.60 31 14.19 472 7 123
14 60.80 31 14.25 410 7 121
15 28.30 31 14.35 396 7 120
16 -0.90 31 14.34 372 9 116
17 -0.70 427 13.95 329 8 215

Cycle 467 GMT 15/ 7/2013 3:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.10 120 14.09 445 7 76
2 1503.30 114 12.36 1430 6 104
3 1225.50 1 14.12 1214 7 126
4 997.90 40 13.51 1078 6 124
5 881.10 31 13.74 1003 7 127
6 811.40 31 13.77 953 6 127
7 719.90 31 13.85 884 6 126
8 626.40 31 13.89 822 6 125
9 523.70 31 13.97 747 6 127
10 404.50 31 14.05 666 6 127
11 280.60 31 14.09 577 7 126
12 154.90 31 14.16 491 7 124
13 76.30 31 14.26 434 7 121
14 34.50 31 14.28 402 7 120
15 14.90 31 14.34 376 8 119
16 1.90 31 14.31 372 10 109
17 -0.70 413 13.92 334 7 220

Cycle 466 GMT 14/ 7/2013 14: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.00 120 14.10 463 7 76
2 1502.30 111 12.35 1422 6 101
3 1244.30 3 13.93 1261 7 127
4 1001.10 40 13.45 1079 6 127
5 896.00 31 13.71 1025 7 127
6 822.50 31 13.75 989 6 127
7 744.90 31 13.83 910 6 126
8 649.50 31 13.90 833 6 125
9 542.80 31 13.93 761 6 127
10 432.60 31 14.02 676 6 127
11 303.40 31 14.09 591 7 127
12 175.80 31 14.17 493 7 125
13 87.30 31 14.24 442 7 122
14 40.00 31 14.30 400 7 120
15 18.10 31 14.32 398 7 118
16 3.80 31 14.30 360 9 116
17 -0.80 31 14.30 372 6 116
18 -0.60 382 13.95 337 10 215

Cycle 465 GMT 14/ 7/2013 0:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.80 61 14.20 454 7 72
2 3001.00 33 12.09 2545 6 98
3 2899.40 14 13.10 2463 6 109
4 2725.60 40 12.37 2350 6 112
5 2633.90 31 12.85 2289 7 120
6 2383.40 31 12.99 2112 7 122
7 2121.40 31 13.14 1902 8 123
8 1970.90 31 13.21 1794 8 130
9 1878.20 31 13.25 1743 9 130
10 1678.10 31 13.31 1579 8 132
11 1594.40 31 13.37 1529 8 130
12 1286.80 31 13.56 1302 7 130
13 950.10 31 13.70 1061 7 132
14 842.00 31 13.79 973 7 132
15 710.90 31 13.88 880 7 132
16 578.90 31 13.92 791 6 129
17 439.70 31 14.02 686 6 132
18 299.00 31 14.06 583 7 131
19 65.90 31 14.20 434 7 125
20 30.00 31 14.32 394 8 124
21 12.10 31 14.31 390 8 124
22 -1.00 30 14.33 380 9 120
23 -0.80 394 13.89 337 9 193

Cycle 464 GMT 12/ 7/2013 22:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.50 61 14.21 448 7 75
2 3000.70 53 11.69 2530 6 97
3 2795.30 6 13.32 2412 6 114
4 2632.30 40 12.39 2279 6 113
5 2528.70 31 12.94 2178 7 122
6 2225.80 31 13.01 1985 7 127
7 2168.40 31 13.11 1929 8 129
8 1919.00 31 13.24 1747 8 130
9 1828.50 31 13.24 1703 9 131
10 1734.90 31 13.30 1632 8 133
11 1423.40 31 13.42 1408 7 132
12 915.00 31 13.71 1035 7 132
13 805.90 31 13.81 946 7 133
14 696.10 31 13.90 866 7 133
15 571.40 31 13.96 789 6 130
16 442.00 31 14.06 678 6 131
17 305.00 31 14.08 591 7 131
18 162.30 31 14.17 513 7 129
19 70.60 31 14.23 438 7 125
20 29.10 31 14.34 392 8 124
21 -1.00 31 14.36 386 10 125
22 -0.90 416 13.89 338 9 239

Cycle 463 GMT 11/ 7/2013 21: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.20 17 14.27 472 7 58
2 4000.20 28 11.48 3226 6 88
3 3811.10 8 12.74 3118 6 108
4 3690.60 40 11.86 2999 6 98
5 3593.60 31 12.44 2931 6 103
6 3327.10 31 12.53 2790 6 100
7 2941.20 31 12.74 2489 7 113
8 2885.80 31 12.73 2457 8 115
9 2400.20 31 12.94 2116 7 125
10 1977.50 31 13.16 1815 8 130
11 1902.20 31 13.25 1729 8 133
12 1721.20 31 13.35 1594 8 133
13 1630.80 31 13.35 1553 8 133
14 1435.90 31 13.46 1430 7 134
15 922.70 31 13.68 1031 7 132
16 817.00 31 13.76 966 7 134
17 702.40 31 13.90 882 7 134
18 582.90 31 13.93 799 6 131
19 455.70 31 14.02 692 6 131
20 321.50 31 14.11 614 7 131
21 183.90 31 14.18 517 7 129
22 81.90 31 14.27 430 7 126
23 -0.70 31 14.34 374 7 119
24 -0.70 421 13.94 328 9 137

Cycle 462 GMT 10/ 7/2013 9:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.80 17 14.31 455 7 58
2 4000.90 25 11.55 3209 6 89
3 3847.40 9 12.80 3142 6 109
4 3666.80 40 11.89 2987 6 97
5 3555.80 31 12.48 2918 6 100
6 3441.30 31 12.47 2866 6 107
7 3112.70 31 12.66 2604 7 107
8 2642.50 31 12.82 2281 7 121
9 2590.70 31 12.89 2223 8 124
10 2011.30 31 13.15 1823 7 129
11 1936.60 31 13.24 1769 8 133
12 1847.50 31 13.26 1717 9 132
13 1551.60 31 13.41 1495 8 133
14 1154.50 31 13.60 1209 7 132
15 945.40 31 13.71 1061 7 134
16 836.60 31 13.80 973 7 134
17 726.50 31 13.91 900 7 134
18 610.20 31 13.92 817 6 131
19 481.90 31 14.00 725 6 131
20 347.30 31 14.10 634 7 133
21 203.40 31 14.16 533 7 131
22 38.80 31 14.26 402 7 123
23 1.30 31 14.37 376 7 127
24 -0.70 421 13.88 338 11 145

Cycle 461 GMT 8/ 7/2013 21:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.00 17 14.31 472 7 59
2 4000.80 27 11.60 3241 6 89
3 3833.10 9 12.87 3136 6 106
4 3635.70 40 11.89 2965 6 97
5 3539.40 31 12.50 2902 6 104
6 3297.50 31 12.57 2743 6 100
7 3026.90 31 12.71 2523 7 114
8 2697.80 31 12.84 2294 7 115
9 2375.00 31 12.95 2084 8 127
10 1946.80 31 13.19 1769 8 132
11 1876.50 31 13.23 1733 8 133
12 1788.50 31 13.32 1654 9 135
13 1694.70 31 13.37 1589 8 135
14 1604.60 31 13.41 1541 8 134
15 1060.70 31 13.62 1122 7 131
16 943.80 31 13.74 1033 7 133
17 821.90 31 13.82 944 7 135
18 691.00 31 13.85 878 6 131
19 559.00 31 13.95 783 6 133
20 268.90 31 14.12 569 7 131
21 137.00 31 14.23 472 7 129
22 58.80 31 14.27 414 7 127
23 25.30 31 14.34 386 8 126
24 -0.70 31 14.38 366 9 121
25 -0.80 391 13.90 333 9 136

Cycle 460 GMT 7/ 7/2013 11:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.30 17 14.28 509 7 57
2 4000.80 22 11.64 3242 6 90
3 3839.70 9 12.73 3154 6 99
4 3679.20 40 11.85 3030 6 95
5 3586.40 31 12.44 2965 6 101
6 3527.90 31 12.49 2908 7 106
7 3110.40 31 12.64 2618 7 113
8 2775.20 31 12.80 2390 7 117
9 2438.20 31 12.93 2156 7 126
10 2150.00 31 13.06 1950 8 130
11 1998.50 31 13.17 1840 8 133
12 1807.30 31 13.32 1701 8 132
13 1717.00 31 13.37 1638 8 135
14 1417.00 31 13.42 1438 7 133
15 919.40 31 13.75 1051 7 133
16 820.10 31 13.80 973 7 135
17 704.20 31 13.87 892 7 134
18 585.10 31 13.93 803 6 130
19 451.30 31 14.02 698 6 131
20 312.60 31 14.10 599 7 133
21 74.30 31 14.23 422 7 126
22 32.60 31 14.35 390 7 126
23 1.30 31 14.38 368 7 126
24 -0.60 421 13.87 335 9 139

Cycle 459 GMT 5/ 7/2013 23:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.30 17 14.31 476 7 59
2 4000.30 25 11.75 3233 6 90
3 3815.40 8 12.96 3095 6 105
4 3678.00 40 11.87 2993 6 93
5 3584.30 31 12.47 2930 6 104
6 3526.90 31 12.52 2870 7 103
7 3063.20 31 12.66 2579 6 112
8 2746.30 31 12.82 2332 7 120
9 2627.80 31 12.88 2263 8 119
10 1954.50 31 13.16 1789 7 131
11 1879.40 31 13.28 1731 8 130
12 1786.90 31 13.35 1642 9 134
13 1495.00 31 13.46 1457 8 132
14 1294.90 31 13.56 1306 7 135
15 991.50 31 13.71 1087 7 134
16 882.60 31 13.80 1007 7 135
17 760.70 31 13.83 924 7 136
18 639.30 31 13.97 848 6 131
19 506.70 31 14.02 716 6 132
20 374.00 31 14.08 650 7 134
21 231.50 31 14.18 541 7 132
22 95.00 31 14.26 440 7 129
23 16.30 31 14.37 380 7 124
24 2.70 31 14.30 364 9 123
25 -0.50 31 14.33 358 8 120
26 -0.40 360 13.90 339 9 127

Cycle 458 GMT 4/ 7/2013 12:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.20 17 14.29 486 7 56
2 4000.90 25 11.70 3278 6 79
3 3814.30 8 12.92 3124 6 107
4 3689.20 40 11.88 3030 6 96
5 3615.80 31 12.48 2967 6 106
6 3558.70 31 12.51 2914 7 108
7 3118.80 31 12.65 2644 6 111
8 2609.00 31 12.77 2323 7 123
9 2276.00 31 13.02 2067 7 125
10 1951.40 31 13.15 1834 8 133
11 1883.70 31 13.25 1773 9 135
12 1797.20 31 13.30 1723 9 135
13 1510.00 31 13.36 1541 8 135
14 1315.50 31 13.51 1346 7 133
15 992.20 31 13.72 1120 7 134
16 885.60 31 13.78 1061 7 135
17 752.20 31 13.87 958 7 136
18 640.90 31 13.90 860 6 130
19 508.50 31 14.03 747 6 132
20 372.40 31 14.10 662 7 133
21 238.90 31 14.16 584 7 132
22 42.40 31 14.26 416 7 126
23 2.00 31 14.36 386 8 117
24 -0.80 31 14.31 386 7 124
25 -0.70 391 13.79 342 8 152

Cycle 457 GMT 3/ 7/2013 0:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.10 17 14.32 462 7 58
2 4001.00 27 11.73 3239 6 91
3 3832.30 9 12.85 3142 6 105
4 3660.10 40 11.91 3017 6 86
5 3576.10 31 12.45 2969 6 103
6 3522.80 31 12.49 2926 7 105
7 3033.10 31 12.68 2582 6 114
8 2690.40 31 12.85 2324 7 120
9 2275.70 31 13.00 2025 7 124
10 2021.60 31 13.16 1836 8 130
11 1960.30 31 13.22 1797 9 127
12 1879.70 31 13.29 1739 9 127
13 1788.80 31 13.35 1685 8 131
14 1374.50 31 13.49 1384 7 131
15 1054.00 31 13.63 1152 7 133
16 943.60 31 13.76 1075 7 134
17 828.10 31 13.84 971 7 135
18 712.50 31 13.90 892 6 131
19 583.30 31 13.94 803 6 132
20 441.90 31 14.03 711 7 133
21 166.10 31 14.13 527 7 129
22 70.70 31 14.28 436 7 127
23 32.00 31 14.32 418 8 126
24 -1.10 31 14.31 390 8 129
25 -1.10 391 13.78 350 10 133

Cycle 456 GMT 1/ 7/2013 14: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.40 17 14.29 472 7 56
2 4000.30 20 12.04 3246 6 92
3 3847.00 9 12.81 3130 6 108
4 3714.90 40 10.75 3042 6 77
5 3611.90 31 12.43 2967 6 106
6 3417.00 31 12.58 2852 6 100
7 3098.20 31 12.65 2616 6 109
8 2853.80 31 12.76 2449 7 117
9 2399.10 31 12.99 2090 7 127
10 2002.20 31 13.19 1812 8 132
11 1934.90 31 13.26 1783 9 134
12 1850.40 31 13.28 1715 9 134
13 1754.70 31 13.37 1646 9 131
14 1238.30 31 13.54 1277 7 133
15 942.60 31 13.71 1061 7 134
16 848.60 31 13.85 983 7 134
17 735.70 31 13.91 916 7 134
18 614.80 31 13.94 825 6 131
19 494.50 31 14.05 731 6 132
20 365.70 31 14.05 658 7 132
21 103.10 31 14.26 464 7 127
22 44.00 31 14.31 414 7 126
23 18.60 31 14.36 386 8 125
24 -0.90 31 14.37 378 9 126
25 -0.90 391 13.83 338 11 138

Cycle 455 GMT 29/ 6/2013 13:48: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.40 17 14.28 499 7 57
2 4000.90 22 11.95 3237 6 92
3 3872.80 11 12.75 3204 6 109
4 3661.70 40 10.69 3016 6 84
5 3571.00 31 12.45 2945 6 104
6 3451.50 31 12.56 2874 6 103
7 2967.00 31 12.70 2535 6 107
8 2715.90 31 12.86 2340 7 115
9 2312.50 31 12.99 2076 7 126
10 2053.00 31 13.16 1872 8 129
11 1986.00 31 13.20 1830 9 133
12 1903.90 31 13.26 1757 9 133
13 1616.00 31 13.44 1535 8 133
14 1227.60 31 13.54 1267 7 133
15 918.20 31 13.73 1041 7 133
16 805.90 31 13.84 976 7 134
17 695.70 31 13.82 910 7 134
18 572.70 31 13.99 805 6 131
19 449.50 31 14.04 706 6 131
20 320.60 31 14.11 614 7 132
21 180.70 31 14.22 513 7 130
22 72.80 31 14.31 424 7 128
23 30.80 31 14.34 404 8 126
24 -1.00 31 14.37 386 7 124
25 -1.00 391 13.81 340 11 147

Cycle 454 GMT 27/ 6/2013 14: 6: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.90 17 14.31 469 7 57
2 4000.90 28 11.87 3220 6 89
3 3831.60 8 12.87 3148 6 108
4 3657.40 40 10.74 3017 6 87
5 3544.40 31 12.42 2961 6 98
6 3350.50 31 12.57 2816 6 106
7 3222.30 31 12.65 2721 7 107
8 2729.20 31 12.82 2370 7 113
9 2360.60 31 12.99 2078 7 127
10 2303.10 31 13.07 2060 8 129
11 1976.90 31 13.19 1814 8 129
12 1885.00 31 13.28 1751 9 133
13 1508.00 31 13.41 1501 7 134
14 1205.30 31 13.61 1251 7 134
15 989.20 31 13.73 1086 7 134
16 891.30 31 13.80 1025 7 135
17 764.50 31 13.87 940 7 135
18 646.30 31 13.94 844 7 130
19 512.80 31 14.00 749 6 131
20 379.80 31 14.10 646 7 134
21 239.10 31 14.20 549 7 132
22 101.00 31 14.27 468 7 129
23 41.80 31 14.37 404 8 126
24 1.00 421 13.83 341 8 145

Cycle 453 GMT 25/ 6/2013 14:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.90 17 14.29 476 7 60
2 4000.60 24 12.04 3251 6 90
3 3834.30 9 12.76 3166 6 107
4 3665.30 40 10.74 3021 6 87
5 3559.50 31 12.45 2942 6 106
6 3444.40 31 12.55 2884 6 108
7 3112.20 31 12.69 2656 7 111
8 2792.50 31 12.84 2396 7 116
9 2517.10 31 12.94 2215 8 124
10 2090.80 31 13.12 1892 8 129
11 1915.20 31 13.26 1757 8 131
12 1832.00 31 13.35 1697 9 134
13 1739.90 31 13.34 1656 9 132
14 1426.40 31 13.55 1406 7 133
15 910.50 31 13.67 1047 7 133
16 803.00 31 13.82 967 7 134
17 694.80 31 13.92 882 7 134
18 582.70 31 13.95 807 6 130
19 453.80 31 14.05 688 6 130
20 321.80 31 14.15 626 7 131
21 190.10 31 14.19 535 7 128
22 85.40 31 14.30 444 7 125
23 35.70 31 14.33 412 8 123
24 -0.50 31 14.38 382 8 118
25 -0.50 391 13.82 336 10 135

Cycle 452 GMT 23/ 6/2013 15: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.10 17 14.32 476 7 60
2 4000.50 20 12.21 3225 6 93
3 3835.60 8 12.84 3118 6 105
4 3724.90 40 10.91 3041 6 87
5 3639.40 31 12.44 2993 6 104
6 3582.20 31 12.51 2947 7 103
7 3182.70 31 12.65 2699 6 103
8 2788.30 31 12.76 2424 7 111
9 2531.70 31 12.93 2219 8 123
10 2123.80 31 13.11 1926 8 129
11 1969.60 31 13.20 1820 8 133
12 1892.10 31 13.31 1737 9 133
13 1802.10 31 13.36 1694 9 135
14 1494.40 31 13.47 1475 7 132
15 991.90 31 13.72 1097 7 132
16 878.60 31 13.78 1027 7 134
17 766.20 31 13.91 948 7 134
18 648.40 31 13.93 866 7 127
19 529.60 31 13.99 791 6 131
20 395.90 31 14.10 689 7 132
21 261.60 31 14.18 585 7 131
22 53.90 31 14.28 440 7 124
23 23.10 31 14.37 400 8 124
24 -0.30 31 14.33 390 8 117
25 -0.40 391 13.75 348 7 125

Cycle 451 GMT 21/ 6/2013 14:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.80 17 14.31 472 7 59
2 4000.60 24 11.95 3247 6 88
3 3826.10 9 12.77 3142 6 109
4 3674.00 40 10.84 3030 6 84
5 3586.00 31 12.49 2953 6 104
6 3392.40 31 12.57 2838 6 103
7 3066.00 31 12.70 2596 6 109
8 2876.10 31 12.82 2483 7 116
9 2412.40 31 12.97 2128 7 126
10 1957.40 31 13.16 1791 7 128
11 1886.60 31 13.25 1753 8 132
12 1810.50 31 13.30 1691 9 134
13 1722.80 31 13.35 1630 9 134
14 1312.10 31 13.57 1325 7 133
15 913.80 31 13.75 1039 7 133
16 810.20 31 13.81 969 7 134
17 699.50 31 13.89 888 7 135
18 577.70 31 14.02 789 7 129
19 449.30 31 14.07 711 6 131
20 314.20 31 14.16 598 7 131
21 182.50 31 14.23 499 7 129
22 76.70 31 14.36 432 7 126
23 31.80 31 14.40 384 8 125
24 14.90 31 14.36 390 8 123
25 4.40 31 14.32 376 8 118
26 -0.50 31 14.36 366 10 121
27 -0.40 328 13.82 339 8 143

Cycle 450 GMT 19/ 6/2013 13:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.50 17 14.34 482 7 59
2 4000.80 24 12.10 3213 6 92
3 3904.50 14 12.89 3182 6 107
4 3585.10 40 10.96 2951 6 82
5 3491.80 31 12.57 2852 6 106
6 3313.90 31 12.66 2735 6 109
7 3054.50 31 12.77 2543 7 113
8 2641.70 31 12.91 2269 7 122
9 2306.60 31 13.03 2031 8 126
10 2036.30 31 13.14 1864 8 125
11 1956.80 31 13.25 1781 9 128
12 1768.50 31 13.39 1634 8 135
13 1678.80 31 13.42 1569 8 133
14 1066.00 31 13.68 1140 7 134
15 963.10 31 13.79 1055 7 135
16 861.20 31 13.86 989 7 135
17 747.50 31 13.94 888 7 135
18 619.30 31 13.99 827 6 131
19 492.90 31 14.09 717 6 132
20 356.50 31 14.17 614 7 133
21 213.40 31 14.25 527 7 131
22 87.00 31 14.33 448 7 128
23 37.40 31 14.31 406 8 125
24 0.00 31 14.39 362 7 127
25 -0.60 391 13.79 331 8 146

Cycle 449 GMT 17/ 6/2013 15: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.10 17 14.35 458 7 59
2 4000.40 23 12.11 3229 6 93
3 3896.60 12 12.98 3194 6 106
4 3651.40 40 10.93 3041 6 85
5 3559.10 31 12.51 2941 6 106
6 3378.30 31 12.62 2801 6 108
7 3062.80 31 12.70 2592 6 108
8 2741.30 31 12.87 2346 7 120
9 2229.70 31 12.99 1997 7 127
10 2173.00 31 13.18 1938 8 131
11 1938.00 31 13.28 1771 8 129
12 1855.50 31 13.35 1713 9 131
13 1762.70 31 13.36 1660 8 134
14 1270.20 31 13.52 1297 7 134
15 966.80 31 13.74 1069 7 133
16 853.80 31 13.83 993 7 134
17 746.30 31 13.91 908 7 134
18 613.00 31 14.04 803 7 133
19 488.90 31 14.11 706 6 131
20 354.20 31 14.15 626 7 133
21 210.40 31 14.27 521 7 130
22 84.60 31 14.33 444 7 127
23 13.50 31 14.38 378 7 123
24 0.50 31 14.33 378 10 117
25 -0.50 391 13.76 329 7 147

Cycle 448 GMT 15/ 6/2013 16:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.40 17 14.31 462 7 59
2 4000.70 21 12.22 3242 6 95
3 3887.60 13 12.87 3186 6 105
4 3630.70 40 11.08 2974 6 91
5 3533.70 31 12.52 2937 6 108
6 3345.40 31 12.64 2783 6 99
7 3158.20 31 12.68 2670 7 112
8 2703.00 31 12.83 2340 7 122
9 2301.10 31 13.03 2027 7 127
10 1963.10 31 13.22 1780 8 131
11 1890.30 31 13.34 1727 9 133
12 1809.90 31 13.34 1664 9 136
13 1714.50 31 13.44 1602 8 135
14 1111.80 31 13.64 1160 7 134
15 1023.90 31 13.78 1096 7 135
16 914.10 31 13.85 1027 7 135
17 791.90 31 13.93 934 7 135
18 669.30 31 13.97 839 7 130
19 539.70 31 14.05 759 6 131
20 401.80 31 14.14 648 7 133
21 121.10 31 14.25 460 7 127
22 51.50 31 14.37 412 7 125
23 -0.60 31 14.36 390 8 124
24 -0.60 421 13.71 344 9 135

Cycle 447 GMT 13/ 6/2013 18:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.40 17 14.30 476 7 58
2 4000.40 22 12.19 3235 6 93
3 3901.80 14 12.92 3186 6 104
4 3627.00 40 11.10 2983 6 92
5 3541.50 31 12.52 2918 6 101
6 3485.30 31 12.63 2854 7 103
7 3144.80 31 12.68 2646 7 113
8 2613.90 31 12.87 2261 7 124
9 2554.00 31 12.98 2205 8 126
10 1972.20 31 13.20 1797 7 130
11 1909.20 31 13.28 1743 8 133
12 1823.40 31 13.38 1678 9 135
13 1728.90 31 13.39 1620 8 136
14 1328.00 31 13.53 1322 7 134
15 918.20 31 13.75 1031 7 133
16 819.30 31 13.86 963 7 135
17 710.00 31 13.93 884 7 134
18 586.70 31 13.99 795 7 129
19 454.20 31 14.13 703 6 131
20 316.70 31 14.19 595 7 132
21 78.10 31 14.31 445 7 126
22 33.80 31 14.32 398 7 124
23 -0.30 31 14.38 372 12 121
24 -0.40 421 13.75 329 10 138

Cycle 446 GMT 11/ 6/2013 20:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.70 17 14.33 462 7 57
2 4001.10 25 12.13 3209 6 93
3 3906.60 14 12.91 3182 6 109
4 3610.10 40 11.11 2957 6 83
5 3504.50 31 12.56 2902 6 99
6 3319.30 31 12.62 2777 6 109
7 3121.00 31 12.75 2618 7 116
8 2579.10 31 12.87 2219 7 122
9 2520.10 31 13.01 2178 8 127
10 1987.50 31 13.19 1799 7 131
11 1918.30 31 13.33 1741 8 134
12 1824.60 31 13.36 1687 9 133
13 1534.70 31 13.51 1487 8 136
14 1439.30 31 13.56 1396 8 134
15 1133.80 31 13.69 1184 7 133
16 913.70 31 13.85 1011 7 134
17 791.20 31 13.86 938 7 135
18 660.30 31 14.00 846 7 130
19 529.60 31 14.05 743 6 133
20 245.20 31 14.23 551 7 130
21 103.30 31 14.35 456 7 128
22 49.50 31 14.38 416 7 125
23 21.10 31 14.34 424 8 123
24 -0.40 31 14.36 400 9 123
25 -0.30 391 13.68 359 8 137

Cycle 445 GMT 9/ 6/2013 22:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.70 9 14.35 464 7 53
2 4000.50 30 12.05 3251 6 79
3 3911.50 14 12.87 3174 6 101
4 3654.60 40 11.19 3010 6 94
5 3547.40 31 12.57 2904 6 99
6 3426.70 31 12.60 2864 6 111
7 3229.10 31 12.77 2668 7 115
8 2626.70 31 12.85 2304 7 122
9 2323.30 31 13.00 2084 7 128
10 1948.50 31 13.21 1779 8 130
11 1892.80 31 13.29 1745 8 134
12 1814.40 31 13.34 1692 9 136
13 1419.10 31 13.51 1408 7 134
14 1129.50 31 13.67 1183 7 135
15 938.90 31 13.82 1041 7 135
16 831.10 31 13.86 958 7 135
17 713.00 31 13.95 880 7 135
18 594.60 31 14.03 793 7 129
19 458.00 31 14.10 697 6 131
20 326.40 31 14.21 597 7 132
21 188.50 31 14.30 505 7 129
22 80.90 31 14.38 424 7 126
23 33.90 31 14.41 384 8 123
24 -0.50 31 14.39 378 8 119
25 -0.50 391 13.79 326 9 129

Cycle 444 GMT 8/ 6/2013 1:18: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 4003.20 69 11.45 3251 6 95
2 3900.90 14 13.08 3197 6 109
3 3453.40 40 11.72 2873 6 99
4 3360.20 31 12.60 2840 6 110
5 3104.40 31 12.72 2618 6 105
6 2796.40 31 12.83 2424 7 107
7 2475.40 31 12.97 2168 7 125
8 2022.40 31 13.11 1844 7 129
9 1958.50 31 13.27 1783 8 133
10 1873.80 31 13.37 1723 9 131
11 1680.90 31 13.46 1592 8 136
12 1385.80 31 13.56 1384 7 134
13 981.10 31 13.74 1088 7 133
14 879.50 31 13.90 1001 7 135
15 774.00 31 13.95 940 7 135
16 654.40 31 13.99 850 7 134
17 530.80 31 14.11 761 6 130
18 263.00 31 14.17 577 6 130
19 133.00 31 14.37 481 7 128
20 62.50 31 14.40 416 7 125
21 27.10 31 14.39 394 8 122
22 11.00 31 14.27 384 8 120
23 -0.20 31 14.31 362 9 119
24 -0.30 391 13.72 340 10 169

Cycle 443 GMT 6/ 6/2013 6:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.70 17 14.35 472 7 61
2 4000.90 25 12.22 3242 6 93
3 3905.20 14 12.76 3217 6 104
4 3619.90 40 11.24 3010 6 94
5 3521.10 31 12.48 2947 6 104
6 3330.10 31 12.66 2797 6 109
7 3207.50 31 12.73 2707 7 108
8 2815.40 31 12.91 2416 7 119
9 2352.00 31 13.01 2104 7 126
10 2027.10 31 13.12 1892 8 132
11 1956.60 31 13.25 1811 9 134
12 1875.90 31 13.27 1769 9 133
13 1579.70 31 13.46 1525 8 134
14 1488.90 31 13.53 1463 8 135
15 1065.50 31 13.72 1154 7 133
16 949.90 31 13.79 1078 7 136
17 832.60 31 13.89 975 7 136
18 700.30 31 13.97 898 6 132
19 573.60 31 14.07 801 6 132
20 434.60 31 14.14 701 7 134
21 66.50 31 14.36 444 7 124
22 27.10 31 14.37 398 7 122
23 -0.30 31 14.38 392 7 119
24 -0.30 421 13.68 343 9 139

Cycle 442 GMT 4/ 6/2013 8:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.70 17 14.34 479 7 63
2 4000.20 12 12.64 3218 6 95
3 3940.00 2 13.09 3190 6 97
4 3899.80 40 10.82 3188 6 89
5 3808.40 31 12.41 3148 6 101
6 3750.60 31 12.43 3116 6 103
7 3350.20 31 12.66 2811 6 105
8 3081.70 31 12.72 2638 7 114
9 2605.70 31 12.92 2287 7 123
10 2229.10 31 13.10 1995 8 129
11 1943.50 31 13.23 1789 8 132
12 1865.20 31 13.29 1745 9 134
13 1675.70 31 13.38 1642 8 134
14 1487.10 31 13.54 1459 8 136
15 1193.60 31 13.65 1251 7 135
16 966.00 31 13.81 1075 7 135
17 860.30 31 13.90 1009 7 134
18 737.20 31 13.96 928 7 135
19 616.60 31 14.04 832 6 132
20 482.60 31 14.08 751 6 133
21 344.90 31 14.17 652 7 133
22 205.30 31 14.27 545 7 131
23 33.80 31 14.38 426 7 122
24 14.90 31 14.29 406 8 122
25 -0.20 390 13.71 353 10 122

Cycle 441 GMT 1/ 6/2013 9:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.40 17 14.34 472 7 59
2 3984.60 6 12.78 3237 6 95
3 3968.30 4 13.31 3202 6 103
4 4005.30 40 11.12 3270 6 88
5 3962.30 31 12.33 3249 6 93
6 3713.70 31 12.43 3086 6 103
7 3396.00 31 12.53 2864 6 108
8 3215.70 31 12.70 2713 7 104
9 2669.90 31 12.89 2324 7 119
10 2215.30 31 13.06 1985 7 128
11 1958.60 31 13.25 1816 8 133
12 1887.30 31 13.29 1767 9 127
13 1698.50 31 13.41 1628 8 133
14 1613.40 31 13.48 1567 8 136
15 1203.70 31 13.61 1267 7 134
16 1013.10 31 13.78 1116 7 135
17 910.50 31 13.85 1045 7 135
18 788.10 31 13.93 961 7 135
19 669.80 31 13.98 872 7 129
20 553.40 31 14.06 787 6 131
21 414.00 31 14.16 692 7 133
22 271.90 31 14.26 585 7 132
23 123.00 453 13.51 411 7 128

Cycle 440 GMT 29/ 5/2013 20:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.90 17 14.32 479 7 59
2 4000.60 8 12.69 3279 6 93
3 3951.40 3 13.02 3261 6 89
4 3952.00 40 10.87 3245 6 89
5 3857.70 31 12.38 3172 6 98
6 3798.70 31 12.45 3112 6 105
7 3336.00 31 12.59 2809 6 110
8 3215.40 31 12.73 2707 7 114
9 2550.30 31 12.91 2245 7 123
10 2298.60 31 13.06 2082 8 128
11 1972.80 31 13.20 1830 8 132
12 1897.50 31 13.29 1767 9 134
13 1809.60 31 13.40 1686 9 135
14 1618.60 31 13.46 1568 8 135
15 1423.50 31 13.55 1426 7 134
16 987.60 31 13.76 1100 7 133
17 884.00 31 13.84 1023 7 135
18 771.30 31 13.95 948 7 135
19 652.60 31 14.02 878 7 129
20 524.40 31 14.05 785 6 131
21 389.30 31 14.17 684 7 133
22 102.40 31 14.33 485 7 126
23 45.20 31 14.33 444 7 123
24 18.80 31 14.31 430 8 122
25 -0.20 31 14.26 460 8 117
26 -0.20 360 13.60 374 9 112

Cycle 439 GMT 26/ 5/2013 20:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 17 14.29 493 7 60
2 4000.90 12 12.49 3261 6 91
3 3939.50 2 12.96 3285 6 101
4 3891.10 40 11.00 3219 6 92
5 3798.70 25 12.59 3147 6 98
6 3740.60 25 12.61 3118 6 109
7 3287.20 25 12.79 2778 6 108
8 3101.20 25 12.94 2644 7 113
9 2834.10 25 12.94 2509 7 121
10 2578.10 25 13.08 2273 8 127
11 2233.60 25 13.22 2044 8 128
12 2174.00 25 13.30 1963 8 134
13 1928.30 25 13.42 1792 8 134
14 1858.80 25 13.44 1737 9 137
15 1776.60 25 13.49 1685 9 138
16 1466.50 25 13.58 1475 7 132
17 1067.10 25 13.77 1156 7 135
18 986.90 25 13.87 1111 7 135
19 869.10 25 13.91 1042 7 135
20 749.60 25 14.03 937 7 135
21 635.50 25 14.05 849 7 134
22 510.00 25 14.14 794 6 131
23 379.70 25 14.25 656 6 130
24 242.50 25 14.30 568 7 129
25 105.30 25 14.38 504 7 126
26 44.60 25 14.41 461 7 123
27 18.90 25 14.23 490 8 122
28 -0.20 25 14.30 449 7 118
29 -0.10 437 13.63 354 8 191

Cycle 438 GMT 23/ 5/2013 19:18: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.90 17 14.39 499 7 59
2 3984.60 6 12.87 3253 6 89
3 3972.10 5 13.18 3205 6 95
4 3947.90 40 11.06 3231 6 92
5 3871.20 25 12.58 3206 6 102
6 3819.70 25 12.59 3163 6 108
7 3442.00 25 12.80 2873 6 102
8 3320.20 25 12.87 2804 7 115
9 2881.70 25 13.01 2480 7 111
10 2821.80 25 13.03 2447 8 120
11 2361.50 25 13.15 2130 7 128
12 2015.70 25 13.29 1880 8 130
13 1950.50 25 13.40 1806 8 136
14 1854.70 25 13.47 1730 9 138
15 1672.40 25 13.51 1623 8 135
16 1483.30 25 13.65 1468 8 137
17 1288.50 25 13.73 1354 7 136
18 1001.40 25 13.81 1132 7 133
19 903.00 25 13.91 1068 7 135
20 784.90 25 14.01 956 7 135
21 657.20 25 14.09 863 7 135
22 539.10 25 14.14 792 7 128
23 414.20 25 14.25 682 6 130
24 279.50 25 14.32 597 7 130
25 147.70 25 14.37 502 7 128
26 64.00 25 14.42 432 7 123
27 31.00 25 14.36 406 8 122
28 14.80 25 14.35 394 8 122
29 4.00 25 14.29 384 9 119
30 -0.10 25 14.27 399 7 117

Cycle 437 GMT 20/ 5/2013 19:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.50 17 14.35 476 7 57
2 4000.10 9 12.68 3273 6 97
3 3951.00 3 13.02 3214 6 102
4 3939.40 40 11.17 3267 6 89
5 3859.90 25 12.64 3180 6 103
6 3603.50 25 12.74 3009 6 110
7 3544.70 25 12.69 2983 7 112
8 3142.70 25 12.94 2673 6 111
9 2903.50 25 12.96 2516 7 116
10 2599.60 25 13.04 2301 7 126
11 2252.50 25 13.20 2054 8 128
12 1968.70 25 13.35 1828 8 131
13 1908.80 25 13.45 1773 9 136
14 1838.60 25 13.47 1735 9 128
15 1752.00 25 13.53 1661 9 137
16 1450.50 25 13.63 1440 7 130
17 1262.20 25 13.75 1311 7 134
18 949.10 25 13.86 1082 7 135
19 841.90 25 13.92 1014 7 135
20 727.00 25 14.03 920 7 135
21 603.60 25 14.12 830 7 135
22 478.90 25 14.16 730 7 129
23 352.10 25 14.27 649 6 130
24 217.60 25 14.32 561 7 129
25 102.40 25 14.34 473 7 125
26 46.50 25 14.37 442 7 123
27 20.70 25 14.32 420 8 122
28 7.90 25 14.31 404 8 118
29 -0.30 25 14.24 411 8 113
30 -0.20 421 13.55 377 9 205

Cycle 436 GMT 17/ 5/2013 19:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.50 17 14.35 476 7 59
2 4000.60 14 12.64 3305 6 92
3 3943.20 3 12.87 3214 6 95
4 3841.00 40 11.33 3188 6 94
5 3754.30 25 12.69 3133 6 101
6 3699.90 25 12.65 3085 6 109
7 3249.00 25 12.84 2773 6 113
8 3192.00 25 12.86 2694 7 113
9 3071.70 25 12.95 2640 7 119
10 2506.40 25 13.10 2218 7 128
11 2104.00 25 13.31 1925 7 132
12 1971.90 25 13.38 1859 8 133
13 1897.60 25 13.46 1787 9 137
14 1814.40 25 13.45 1761 9 138
15 1437.70 25 13.59 1461 7 133
16 1347.00 25 13.69 1380 8 135
17 1057.30 25 13.79 1154 7 134
18 951.20 25 13.89 1097 7 136
19 834.10 25 13.98 1009 7 135
20 712.90 25 14.02 908 7 135
21 599.90 25 14.12 825 7 136
22 480.00 25 14.15 728 7 130
23 350.70 25 14.24 658 6 130
24 218.80 25 14.34 551 7 130
25 95.30 25 14.37 473 7 127
26 44.70 25 14.39 435 7 124
27 19.40 25 14.35 399 8 122
28 -0.20 25 14.35 404 7 120
29 -0.30 434 13.61 357 7 197

Cycle 435 GMT 14/ 5/2013 20:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.90 17 14.37 479 7 58
2 4000.30 8 12.77 3261 6 95
3 3936.10 2 12.96 3249 6 99
4 3946.70 40 11.40 3288 6 86
5 3851.90 25 12.66 3182 6 103
6 3793.20 25 12.62 3142 6 108
7 3522.60 25 12.81 2942 6 111
8 3211.00 25 12.88 2725 6 108
9 2897.70 25 12.95 2537 7 115
10 2439.10 25 13.10 2185 7 127
11 2379.50 25 13.20 2128 8 126
12 1963.00 25 13.38 1811 8 134
13 1889.90 25 13.46 1761 8 136
14 1814.50 25 13.47 1735 9 137
15 1725.20 25 13.54 1659 9 138
16 1417.50 25 13.70 1418 7 135
17 1325.00 25 13.71 1354 7 137
18 907.40 25 13.87 1054 7 135
19 808.60 25 13.98 980 7 135
20 700.40 25 14.04 925 7 136
21 586.10 25 14.13 835 7 134
22 462.00 25 14.20 744 7 133
23 334.90 25 14.29 656 6 129
24 195.00 25 14.35 551 7 128
25 84.60 25 14.42 468 7 124
26 38.80 25 14.37 447 7 122
27 16.40 25 14.31 416 8 121
28 1.10 472 13.61 354 8 234

Cycle 434 GMT 11/ 5/2013 19:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.40 17 14.32 493 7 58
2 3986.40 6 12.81 3269 6 81
3 3982.80 6 12.97 3332 6 103
4 3939.70 40 11.44 3274 6 95
5 3839.50 25 12.61 3209 6 99
6 3714.90 25 12.69 3140 6 108
7 3460.60 25 12.83 2889 6 111
8 3213.40 25 12.92 2706 6 117
9 2817.10 25 13.02 2437 7 123
10 2564.70 25 13.18 2254 7 123
11 2251.90 25 13.33 2006 8 129
12 1985.50 25 13.42 1830 8 131
13 1916.80 25 13.42 1789 8 134
14 1841.90 25 13.47 1751 9 137
15 1746.30 25 13.60 1644 9 138
16 1653.20 25 13.62 1585 8 133
17 1240.30 25 13.68 1311 7 135
18 948.80 25 13.85 1073 7 135
19 842.60 25 13.91 1002 7 136
20 729.80 25 14.07 928 7 135
21 614.10 25 14.10 847 7 136
22 484.90 25 14.22 756 7 134
23 361.00 25 14.25 680 6 130
24 230.30 25 14.39 566 7 129
25 102.40 25 14.42 476 7 126
26 45.00 25 14.40 432 7 123
27 3.30 25 14.37 404 8 121
28 -0.30 25 14.32 406 7 120
29 -0.20 442 13.61 352 8 202

Cycle 433 GMT 8/ 5/2013 19:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.20 17 14.33 496 7 59
2 4000.70 9 12.81 3320 6 95
3 3957.40 3 12.78 3309 6 95
4 3921.60 40 11.52 3261 6 96
5 3810.90 25 12.72 3140 6 99
6 3621.80 25 12.77 3049 6 107
7 3504.40 25 12.79 2944 6 111
8 2986.00 25 12.96 2563 6 117
9 2926.20 25 12.95 2537 7 120
10 2588.60 25 13.17 2287 7 127
11 2390.30 25 13.27 2142 8 130
12 1955.70 25 13.39 1830 8 135
13 1880.50 25 13.41 1773 8 135
14 1798.50 25 13.52 1706 9 138
15 1712.90 25 13.59 1644 8 138
16 1522.60 25 13.66 1523 8 136
17 1127.80 25 13.79 1197 7 135
18 921.20 25 13.93 1073 7 135
19 819.80 25 14.00 1013 7 136
20 709.80 25 14.08 918 7 136
21 584.70 25 14.15 823 7 136
22 458.70 25 14.24 723 7 136
23 330.70 25 14.31 637 6 129
24 202.20 25 14.39 544 6 128
25 86.20 25 14.44 468 7 125
26 38.70 25 14.38 435 7 123
27 17.10 25 14.30 430 8 122
28 -0.10 25 14.33 420 7 117
29 -0.10 439 13.57 379 9 192

Cycle 432 GMT 5/ 5/2013 18:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 17 14.33 489 7 59
2 4000.50 8 12.93 3314 6 91
3 3939.30 2 13.05 3261 6 101
4 3948.70 40 11.61 3258 6 94
5 3844.90 25 12.64 3211 6 90
6 3724.70 25 12.78 3073 6 110
7 3460.90 25 12.82 2925 6 112
8 3095.20 25 12.92 2709 6 112
9 3036.00 25 12.91 2649 7 118
10 2693.30 25 13.14 2359 7 127
11 2430.80 25 13.21 2182 8 127
12 2018.00 25 13.40 1859 8 132
13 1945.70 25 13.46 1804 8 134
14 1854.70 25 13.47 1754 9 137
15 1759.00 25 13.60 1668 9 137
16 1453.40 25 13.67 1475 7 135
17 1362.70 25 13.75 1399 8 138
18 1065.80 25 13.87 1187 7 135
19 953.20 25 13.94 1092 7 135
20 839.50 25 14.01 1025 7 136
21 709.00 25 14.10 928 7 136
22 581.10 25 14.16 828 7 135
23 450.70 25 14.23 730 6 131
24 314.30 25 14.32 628 6 131
25 179.20 25 14.41 537 7 130
26 75.50 25 14.41 471 7 125
27 30.80 25 14.42 430 7 122
28 -0.20 25 14.40 408 7 115
29 -0.30 447 13.59 365 7 253

Cycle 431 GMT 2/ 5/2013 19:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.60 17 14.33 489 7 59
2 3997.30 7 12.97 3277 6 92
3 3958.30 5 13.12 3197 6 102
4 3922.40 40 11.56 3264 6 94
5 3821.60 25 12.69 3196 6 96
6 3761.90 25 12.70 3135 6 93
7 3573.10 25 12.80 3014 6 112
8 3171.90 25 12.86 2749 6 108
9 2718.90 25 13.04 2399 7 122
10 2598.20 25 13.24 2280 8 128
11 2252.90 25 13.26 2056 8 133
12 2050.90 25 13.36 1925 8 135
13 1977.30 25 13.41 1868 9 137
14 1791.30 25 13.56 1716 8 139
15 1700.10 25 13.60 1632 8 139
16 1398.90 25 13.70 1425 7 137
17 1309.40 25 13.77 1361 7 137
18 981.10 25 13.93 1114 7 135
19 870.10 25 13.99 1030 7 135
20 754.00 25 14.10 942 7 136
21 634.20 25 14.15 844 7 136
22 502.10 25 14.21 763 7 136
23 374.80 25 14.33 658 8 135
24 244.50 25 14.39 575 6 128
25 113.70 25 14.46 485 7 125
26 51.80 25 14.40 444 7 123
27 22.30 25 14.33 430 8 120
28 -0.10 25 14.36 408 10 120
29 -0.10 437 13.59 363 9 206

Cycle 430 GMT 29/ 4/2013 19:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.30 17 14.36 523 7 55
2 4001.10 12 12.84 3261 6 96
3 3966.00 5 12.99 3253 6 104
4 3870.40 40 11.67 3197 6 98
5 3782.50 25 12.71 3116 6 97
6 3722.90 25 12.67 3097 6 107
7 3314.20 25 12.95 2801 6 113
8 3119.80 25 13.00 2661 7 119
9 2855.20 25 13.07 2478 7 120
10 2377.50 25 13.24 2118 7 130
11 2115.80 25 13.43 1928 8 132
12 1984.10 25 13.47 1830 8 136
13 1907.40 25 13.51 1782 9 136
14 1823.30 25 13.53 1704 9 139
15 1734.30 25 13.59 1651 8 138
16 1322.30 25 13.74 1342 7 137
17 927.20 25 13.92 1059 7 136
18 828.90 25 14.03 975 7 136
19 727.60 25 14.10 908 7 136
20 607.40 25 14.23 818 7 136
21 492.30 25 14.24 735 7 136
22 366.40 25 14.32 642 8 135
23 233.30 25 14.38 561 8 133
24 110.20 25 14.47 476 8 127
25 48.60 25 14.42 432 8 123
26 20.70 25 14.38 408 8 118
27 -0.20 25 14.34 396 7 112
28 -0.10 453 13.64 345 10 208

Cycle 429 GMT 26/ 4/2013 19:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.20 17 14.37 486 7 58
2 4000.40 8 12.98 3273 6 94
3 3958.70 5 13.14 3214 6 97
4 3917.40 40 11.68 3210 6 96
5 3827.90 25 12.71 3147 6 104
6 3769.50 25 12.66 3171 6 107
7 3285.40 25 12.93 2763 6 111
8 3108.50 25 13.02 2647 7 120
9 2987.40 25 13.03 2568 7 116
10 2641.40 25 13.21 2309 7 121
11 2375.80 25 13.28 2106 8 132
12 1937.00 25 13.50 1778 8 135
13 1862.00 25 13.49 1761 8 136
14 1782.80 25 13.55 1678 9 139
15 1600.80 25 13.67 1547 8 138
16 1513.40 25 13.69 1473 8 139
17 1205.90 25 13.87 1244 7 138
18 990.00 25 14.03 1083 7 137
19 890.00 25 14.00 1016 7 136
20 767.80 25 14.09 932 7 137
21 650.30 25 14.15 856 7 138
22 520.40 25 14.27 751 8 137
23 381.30 25 14.28 647 8 137
24 248.20 25 14.38 559 8 134
25 112.10 25 14.49 456 8 129
26 53.10 25 14.45 416 8 123
27 21.80 25 14.42 384 7 118
28 0.10 25 14.35 385 7 116
29 0.00 432 13.67 345 7 208

Cycle 428 GMT 23/ 4/2013 20:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.70 17 14.36 479 7 59
2 3994.10 7 12.99 3269 6 96
3 3942.30 3 13.15 3214 6 99
4 3931.10 40 11.69 3234 6 94
5 3830.10 25 12.70 3152 6 105
6 3517.70 25 12.84 2923 6 110
7 3458.10 25 12.83 2866 7 114
8 3331.20 25 12.95 2780 7 116
9 2768.10 25 13.12 2408 7 120
10 2457.60 25 13.29 2175 7 126
11 2274.10 25 13.37 2044 8 134
12 1965.10 25 13.51 1823 8 132
13 1898.10 25 13.52 1761 8 137
14 1814.30 25 13.55 1704 9 139
15 1621.10 25 13.65 1590 8 138
16 1336.40 25 13.84 1363 7 137
17 938.50 25 13.99 1078 7 136
18 832.60 25 14.02 1002 7 136
19 731.80 25 14.08 961 7 137
20 622.90 25 14.17 861 7 137
21 506.60 25 14.22 782 7 136
22 379.90 25 14.31 673 7 136
23 251.10 25 14.45 573 7 133
24 123.90 25 14.46 504 7 126
25 53.20 25 14.40 463 7 122
26 23.10 25 14.41 404 7 118
27 8.80 25 14.32 396 7 118
28 0.00 25 14.31 399 8 116
29 -0.20 424 13.62 342 9 208

Cycle 427 GMT 20/ 4/2013 19:43: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.10 43 14.27 464 7 71
2 3400.60 22 12.80 2814 6 105
3 3325.20 1 13.50 2904 6 118
4 3281.30 40 11.98 2767 6 98
5 3200.20 25 12.92 2721 6 115
6 3152.70 25 12.94 2663 7 111
7 2967.30 25 13.12 2535 7 113
8 2477.50 25 13.25 2194 7 128
9 2357.70 25 13.35 2099 8 132
10 2063.40 25 13.50 1909 8 132
11 1997.80 25 13.50 1837 8 135
12 1910.60 25 13.58 1766 9 137
13 1613.90 25 13.71 1554 8 138
14 1418.70 25 13.76 1420 7 138
15 1324.10 25 13.81 1342 8 138
16 906.30 25 13.99 1063 7 137
17 799.40 25 14.07 971 7 137
18 687.10 25 14.14 906 7 137
19 569.90 25 14.23 809 7 136
20 447.60 25 14.23 725 6 128
21 317.60 25 14.35 618 6 129
22 182.30 25 14.42 521 6 127
23 82.00 25 14.46 452 7 124
24 38.30 25 14.44 406 7 121
25 16.10 25 14.34 404 7 119
26 -0.20 456 13.67 337 8 195

Cycle 426 GMT 18/ 4/2013 1:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.20 43 14.31 474 7 71
2 3400.50 29 12.54 2844 6 104
3 3321.70 1 13.81 2785 6 119
4 3199.00 40 12.06 2737 6 105
5 3090.30 25 12.95 2661 6 113
6 2909.40 25 13.12 2516 6 112
7 2851.00 25 13.03 2506 7 119
8 2515.00 25 13.29 2218 7 130
9 1972.50 25 13.39 1856 7 133
10 1902.10 25 13.54 1794 8 138
11 1824.90 25 13.54 1728 8 137
12 1743.80 25 13.59 1673 8 137
13 1654.50 25 13.60 1606 8 138
14 1367.70 25 13.81 1394 7 135
15 1274.20 25 13.85 1308 7 137
16 939.00 25 14.03 1082 7 136
17 828.70 25 14.06 982 7 138
18 708.00 25 14.08 913 7 137
19 588.30 25 14.27 794 8 137
20 456.20 25 14.25 725 7 137
21 325.40 25 14.37 623 7 133
22 190.10 25 14.44 525 6 125
23 82.10 25 14.47 459 6 121
24 37.10 25 14.44 418 7 117
25 0.00 25 14.43 384 8 112
26 0.10 450 13.69 335 7 206

Cycle 425 GMT 15/ 4/2013 8:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.40 43 14.32 485 7 72
2 3401.30 17 12.94 2829 6 106
3 3336.90 3 13.59 2868 6 112
4 3318.50 40 11.97 2804 6 101
5 3240.80 25 12.97 2742 6 108
6 3194.80 25 12.95 2742 7 118
7 3134.90 25 12.91 2682 7 107
8 2627.60 25 13.16 2328 7 116
9 2039.60 25 13.33 1918 7 133
10 1983.50 25 13.46 1856 8 136
11 1914.60 25 13.54 1787 8 134
12 1829.50 25 13.60 1737 8 139
13 1739.60 25 13.57 1673 8 135
14 1648.00 25 13.66 1597 8 138
15 1142.20 25 13.90 1221 7 136
16 925.50 25 14.05 1083 7 137
17 817.50 25 14.09 997 7 135
18 706.20 25 14.10 911 7 137
19 588.50 25 14.21 813 7 136
20 467.00 25 14.26 747 7 137
21 335.30 25 14.40 639 7 135
22 201.70 25 14.44 547 7 131
23 94.40 25 14.46 468 7 124
24 44.70 25 14.49 416 7 119
25 0.90 482 13.70 344 7 220

Cycle 424 GMT 12/ 4/2013 14:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.60 43 14.26 483 7 71
2 3403.70 59 12.04 2821 6 95
3 2916.90 40 12.21 2530 6 100
4 2833.00 25 13.10 2456 6 112
5 2776.20 25 13.10 2420 7 121
6 2348.40 25 13.33 2099 7 131
7 2032.30 25 13.47 1894 7 131
8 1969.30 25 13.46 1859 8 135
9 1887.20 25 13.50 1771 8 138
10 1791.60 25 13.60 1704 8 139
11 1398.00 25 13.81 1404 7 138
12 1118.90 25 13.97 1206 7 138
13 920.80 25 14.06 1073 7 136
14 824.70 25 14.10 999 7 137
15 719.70 25 14.16 908 7 137
16 605.50 25 14.22 830 7 136
17 490.90 25 14.30 758 7 135
18 358.90 25 14.41 642 7 135
19 226.80 25 14.45 566 7 132
20 102.10 25 14.48 476 7 124
21 46.90 25 14.46 432 7 120
22 0.00 25 14.49 394 10 117
23 -0.10 471 13.68 344 9 197

Cycle 423 GMT 9/ 4/2013 22:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.90 42 14.27 487 7 69
2 3401.30 30 12.70 2811 6 104
3 3338.70 2 13.65 2821 6 123
4 3204.50 40 12.14 2737 6 97
5 3101.20 25 13.07 2637 6 118
6 2846.20 25 13.18 2478 6 122
7 2723.30 25 13.25 2370 7 127
8 2602.80 25 13.30 2277 8 129
9 1949.50 25 13.49 1816 7 135
10 1885.00 25 13.56 1761 8 136
11 1817.40 25 13.60 1713 8 137
12 1728.90 25 13.69 1625 8 139
13 1542.40 25 13.77 1521 8 137
14 1242.00 25 13.93 1306 7 138
15 948.20 25 14.05 1087 7 137
16 840.60 25 14.04 1009 7 136
17 730.00 25 14.19 920 7 136
18 618.20 25 14.24 833 7 136
19 492.10 25 14.27 773 8 136
20 366.40 25 14.37 663 8 135
21 235.20 25 14.42 580 8 132
22 109.00 25 14.48 483 8 127
23 48.50 25 14.50 428 7 122
24 22.60 25 14.41 420 7 117
25 13.80 25 14.34 406 7 116
26 0.70 25 14.23 416 8 115
27 -0.30 421 13.57 373 9 208

Cycle 422 GMT 7/ 4/2013 5:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.10 43 14.30 476 7 73
2 3400.80 22 12.86 2877 6 108
3 3333.00 2 13.65 2868 6 116
4 3277.40 40 12.13 2783 6 103
5 3184.70 25 12.96 2732 6 117
6 3126.10 25 13.01 2689 7 110
7 2936.70 25 13.17 2552 7 116
8 2443.60 25 13.33 2166 7 131
9 2168.90 25 13.47 1987 7 135
10 2044.80 25 13.53 1899 8 135
11 1970.70 25 13.52 1840 8 136
12 1880.50 25 13.62 1761 8 137
13 1695.20 25 13.74 1623 8 139
14 1309.20 25 13.88 1368 7 139
15 1213.80 25 13.89 1278 7 138
16 999.90 25 14.08 1125 7 138
17 884.10 25 14.05 1037 7 137
18 768.30 25 14.14 949 7 137
19 636.60 25 14.24 880 7 138
20 512.80 25 14.18 856 8 138
21 375.50 25 14.36 711 8 136
22 237.80 25 14.42 573 8 134
23 108.40 25 14.52 485 8 128
24 46.80 25 14.47 437 7 120
25 19.50 25 14.35 420 7 119
26 -0.50 25 14.40 401 7 115
27 -0.40 429 13.65 354 8 232

Cycle 421 GMT 4/ 4/2013 12:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 17 14.37 499 7 63
2 3999.30 7 13.18 3214 6 94
3 3948.50 3 13.40 3238 6 105
4 3938.60 40 11.81 3249 6 98
5 3834.60 25 12.77 3182 6 105
6 3776.30 25 12.73 3106 6 108
7 3397.40 25 13.04 2859 6 110
8 2977.00 25 13.17 2582 6 121
9 2794.00 25 13.28 2411 7 116
10 2681.00 25 13.26 2349 8 126
11 2321.40 25 13.48 2054 7 133
12 1967.70 25 13.58 1823 8 137
13 1899.10 25 13.53 1794 8 137
14 1813.20 25 13.60 1728 8 140
15 1719.40 25 13.62 1668 8 140
16 1627.50 25 13.72 1587 8 138
17 1532.90 25 13.67 1602 7 134
18 989.60 25 13.98 1197 7 137
19 873.80 25 14.02 1094 7 136
20 762.20 25 14.15 1004 7 137
21 629.50 25 14.19 923 7 136
22 500.90 25 14.28 806 7 135
23 361.40 25 14.35 704 6 132
24 234.00 25 14.48 616 7 132
25 103.60 25 14.50 511 7 126
26 47.60 25 14.50 428 7 123
27 5.80 25 14.48 387 7 120
28 -0.40 25 14.37 382 8 118
29 -0.40 432 13.66 343 10 229

Cycle 420 GMT 1/ 4/2013 12:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.30 17 14.37 503 7 64
2 4000.40 8 12.99 3255 6 96
3 3951.40 3 13.46 3202 6 103
4 3920.20 40 11.84 3222 6 92
5 3817.00 25 12.74 3154 6 105
6 3562.00 25 12.93 2971 6 109
7 3382.60 25 12.99 2859 6 114
8 3137.80 25 13.08 2699 6 120
9 3017.10 25 13.13 2594 7 120
10 2604.50 25 13.32 2285 7 128
11 2071.60 25 13.48 1920 7 133
12 1944.70 25 13.62 1799 8 134
13 1879.00 25 13.65 1756 8 138
14 1793.10 25 13.65 1699 8 140
15 1601.80 25 13.80 1549 8 139
16 1311.30 25 13.95 1354 7 138
17 1020.00 25 14.11 1142 7 138
18 921.20 25 14.07 1073 7 137
19 805.30 25 14.11 980 7 137
20 695.90 25 14.19 913 7 137
21 578.20 25 14.23 851 7 137
22 446.90 25 14.29 754 7 136
23 319.30 25 14.38 656 8 135
24 189.30 25 14.49 537 8 132
25 85.40 25 14.52 471 8 127
26 36.90 25 14.47 408 8 123
27 15.50 25 14.38 404 8 117
28 0.80 448 13.68 357 7 193

Cycle 419 GMT 29/ 3/2013 11:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.00 17 14.40 486 7 66
2 4000.70 8 13.02 3297 6 89
3 3959.00 5 13.41 3237 6 98
4 3888.10 40 11.90 3207 6 91
5 3804.70 25 12.77 3154 6 99
6 3751.10 25 12.80 3073 6 104
7 3361.50 25 13.03 2832 6 114
8 3170.30 25 13.14 2720 7 111
9 2602.00 25 13.32 2304 7 125
10 2424.40 25 13.46 2137 7 129
11 2100.40 25 13.55 1935 7 133
12 1970.70 25 13.65 1816 8 138
13 1892.10 25 13.63 1749 8 139
14 1820.10 25 13.65 1711 8 138
15 1735.30 25 13.68 1658 8 138
16 1414.50 25 13.91 1411 7 138
17 1006.60 25 14.07 1132 7 137
18 912.10 25 14.12 1059 7 137
19 797.90 25 14.12 1006 7 138
20 675.60 25 14.22 908 7 137
21 551.50 25 14.25 818 7 137
22 422.10 25 14.42 702 7 136
23 290.90 25 14.38 623 8 135
24 149.20 25 14.51 520 8 131
25 71.70 25 14.48 456 8 127
26 32.00 25 14.49 413 8 122
27 -0.40 25 14.44 411 7 121
28 -0.40 447 13.67 347 8 219

Cycle 418 GMT 26/ 3/2013 10:49: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.10 17 14.42 486 7 66
2 3983.30 6 13.37 3222 6 97
3 3934.60 2 13.55 3309 6 98
4 3938.40 40 11.94 3237 6 97
5 3846.20 25 12.81 3152 6 105
6 3730.40 25 12.88 3087 6 111
7 3228.00 25 13.09 2759 6 114
8 3107.80 25 13.15 2656 7 120
9 2854.00 25 13.29 2471 7 121
10 2569.40 25 13.39 2287 7 131
11 2448.20 25 13.45 2168 8 133
12 1957.40 25 13.65 1830 7 136
13 1872.50 25 13.59 1754 8 138
14 1777.70 25 13.65 1687 8 138
15 1583.20 25 13.86 1547 8 139
16 1487.30 25 13.82 1456 8 139
17 1093.20 25 14.12 1182 7 138
18 998.30 25 14.02 1175 7 138
19 881.60 25 14.12 1033 7 138
20 764.10 25 14.15 949 7 137
21 647.50 25 14.25 856 7 137
22 513.00 25 14.32 770 7 137
23 381.00 25 14.39 682 8 136
24 241.20 25 14.50 575 8 133
25 109.50 25 14.57 494 6 124
26 47.00 25 14.42 509 7 122
27 20.00 25 14.35 470 7 121
28 -0.10 25 14.38 404 7 121
29 -0.10 424 13.69 347 9 204

Cycle 417 GMT 23/ 3/2013 10:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.80 10 14.44 466 7 60
2 4000.90 14 13.01 3273 6 93
3 3948.00 3 13.65 3214 6 105
4 3934.60 40 11.93 3251 6 92
5 3848.70 25 12.86 3194 6 103
6 3793.00 25 12.79 3133 6 110
7 3386.90 25 13.10 2825 6 114
8 3199.40 25 13.19 2690 6 114
9 2874.40 25 13.34 2473 7 116
10 2818.00 25 13.25 2420 8 121
11 2195.70 25 13.53 2002 7 135
12 1984.10 25 13.65 1823 8 135
13 1900.20 25 13.61 1778 8 139
14 1817.10 25 13.72 1678 8 141
15 1732.20 25 13.76 1632 8 137
16 1327.40 25 13.98 1342 7 138
17 1038.00 25 14.13 1128 7 138
18 926.50 25 14.15 1047 7 136
19 825.00 25 14.16 987 7 137
20 709.90 25 14.25 892 7 137
21 582.90 25 14.29 818 7 137
22 460.60 25 14.35 737 7 137
23 335.20 25 14.47 628 8 136
24 194.90 25 14.51 528 8 132
25 88.90 25 14.54 449 8 128
26 18.00 25 14.53 399 7 122
27 -0.30 25 14.47 392 7 116
28 -0.40 450 13.73 331 11 215

Cycle 416 GMT 20/ 3/2013 12: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.90 10 14.43 490 6 62
2 4000.70 17 12.90 3298 6 93
3 3938.40 2 13.75 3226 6 109
4 3906.50 40 12.06 3210 6 100
5 3806.50 25 12.90 3123 6 101
6 3688.70 25 12.99 3047 6 109
7 3575.00 25 13.00 3004 6 111
8 3146.80 25 13.27 2644 6 121
9 2805.60 25 13.33 2447 7 127
10 2402.00 25 13.51 2142 7 133
11 2343.00 25 13.52 2078 8 135
12 1992.60 25 13.68 1844 8 133
13 1914.80 25 13.67 1775 8 135
14 1827.10 25 13.66 1730 8 140
15 1429.10 25 13.92 1447 7 140
16 1342.00 25 13.90 1370 7 139
17 942.70 25 14.19 1092 7 138
18 853.40 25 14.14 1030 7 138
19 745.00 25 14.23 928 7 137
20 635.90 25 14.23 849 7 137
21 515.60 25 14.34 763 7 136
22 386.40 25 14.39 656 7 136
23 251.60 25 14.47 568 7 133
24 122.80 25 14.61 475 7 129
25 53.80 25 14.54 418 7 125
26 22.20 25 14.47 392 7 118
27 -0.50 25 14.44 392 7 116
28 -0.50 439 13.72 339 7 197

Cycle 415 GMT 17/ 3/2013 12:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.90 10 14.48 490 6 62
2 4000.70 21 12.81 3300 6 98
3 3919.60 1 13.81 3214 6 109
4 3885.60 40 12.10 3195 6 97
5 3793.70 25 12.95 3140 6 107
6 3736.20 25 12.87 3078 6 111
7 3396.10 25 13.15 2875 6 120
8 2999.80 25 13.36 2561 6 122
9 2756.20 25 13.42 2420 7 130
10 2551.20 25 13.51 2251 7 132
11 2196.00 25 13.61 2021 7 134
12 1980.50 25 13.74 1844 8 139
13 1912.50 25 13.69 1778 8 136
14 1828.80 25 13.75 1711 8 138
15 1738.60 25 13.77 1656 8 140
16 1239.30 25 14.05 1313 7 138
17 1155.60 25 14.04 1232 7 136
18 950.90 25 14.16 1099 7 138
19 832.10 25 14.21 997 7 137
20 719.80 25 14.28 904 7 138
21 603.20 25 14.30 823 7 137
22 477.60 25 14.37 735 7 137
23 345.30 25 14.44 639 8 135
24 206.90 25 14.45 551 8 133
25 88.20 25 14.59 456 8 128
26 38.30 25 14.53 401 7 123
27 18.10 25 14.42 416 7 120
28 -0.20 443 13.73 346 7 226

Cycle 414 GMT 14/ 3/2013 14:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.10 10 14.49 476 7 61
2 4001.40 27 12.76 3235 6 92
3 3924.00 1 13.81 3238 6 110
4 3827.90 40 12.20 3185 6 102
5 3740.00 25 13.06 3092 6 107
6 3495.90 25 13.22 2894 6 113
7 3307.70 25 13.25 2773 6 110
8 3184.50 25 13.29 2687 7 122
9 2501.30 25 13.58 2206 7 123
10 2202.40 25 13.70 2002 7 135
11 2147.80 25 13.60 1971 8 135
12 1988.60 25 13.73 1825 8 139
13 1898.80 25 13.65 1789 8 140
14 1809.30 25 13.77 1692 8 140
15 1414.10 25 13.99 1432 7 139
16 1139.70 25 14.14 1220 7 139
17 918.00 25 14.27 1063 7 138
18 822.90 25 14.26 997 7 138
19 715.50 25 14.28 906 7 138
20 602.10 25 14.28 832 7 137
21 477.40 25 14.34 749 7 137
22 342.30 25 14.47 647 7 135
23 202.60 25 14.55 532 7 133
24 93.70 25 14.49 480 7 128
25 41.50 25 14.57 420 7 124
26 1.50 485 13.76 353 7 206

Cycle 413 GMT 11/ 3/2013 16:19: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 10 14.48 509 7 59
2 4000.30 19 13.05 3237 6 97
3 3949.50 3 13.74 3285 6 102
4 3876.20 40 12.24 3201 6 99
5 3784.90 25 13.09 3111 6 105
6 3727.40 25 12.98 3075 6 109
7 3339.40 25 13.24 2828 6 117
8 2869.80 25 13.49 2449 6 125
9 2814.50 25 13.34 2416 7 119
10 2754.50 25 13.40 2378 8 121
11 2286.60 25 13.72 2011 7 137
12 1995.30 25 13.81 1842 8 135
13 1927.20 25 13.69 1775 8 138
14 1840.60 25 13.72 1732 8 140
15 1653.30 25 13.92 1595 8 140
16 1358.80 25 14.08 1382 7 140
17 1067.10 25 14.22 1161 7 139
18 963.80 25 14.18 1073 7 139
19 845.00 25 14.25 975 7 138
20 719.70 25 14.27 908 7 138
21 595.20 25 14.34 813 7 138
22 467.50 25 14.41 716 7 137
23 343.10 25 14.54 614 8 136
24 204.40 25 14.62 525 8 133
25 86.60 25 14.58 442 7 128
26 38.60 25 14.58 406 7 121
27 16.50 25 14.46 399 7 120
28 3.50 25 14.42 382 7 120
29 0.00 25 14.37 387 7 121
30 0.00 382 13.74 338 8 192

Cycle 412 GMT 8/ 3/2013 17:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.60 11 14.49 480 7 59
2 4000.60 13 13.28 3245 6 96
3 3953.40 3 13.84 3178 6 108
4 3933.40 40 12.27 3203 6 102
5 3828.40 25 13.05 3171 6 110
6 3707.30 25 13.10 3075 6 114
7 3260.40 25 13.34 2768 6 117
8 3137.70 25 13.37 2687 7 122
9 2621.90 25 13.64 2294 7 132
10 2501.60 25 13.63 2192 7 132
11 1973.60 25 13.84 1842 7 136
12 1902.60 25 13.82 1737 8 140
13 1824.90 25 13.78 1716 8 141
14 1738.50 25 13.79 1689 8 142
15 1644.00 25 13.89 1585 8 141
16 1347.20 25 14.10 1382 7 139
17 1052.10 25 14.25 1168 7 139
18 949.50 25 14.15 1083 7 138
19 838.90 25 14.30 973 7 138
20 724.40 25 14.33 901 7 138
21 594.90 25 14.36 820 7 139
22 470.40 25 14.44 709 7 136
23 336.70 25 14.52 621 8 135
24 199.40 25 14.59 518 8 133
25 86.30 25 14.60 440 7 129
26 38.50 25 14.60 396 7 124
27 18.80 25 14.54 370 7 120
28 5.70 25 14.41 377 7 116
29 0.00 25 14.42 366 10 124
30 0.30 385 13.74 356 8 225

Cycle 411 GMT 5/ 3/2013 18:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.10 11 14.51 518 7 59
2 4000.60 16 13.18 3227 6 95
3 3946.00 3 13.84 3261 6 102
4 3888.50 40 12.35 3218 6 99
5 3800.10 25 13.09 3140 6 106
6 3744.30 25 13.04 3085 6 115
7 3489.80 25 13.34 2921 6 109
8 2963.60 25 13.56 2516 6 125
9 2842.50 25 13.49 2451 7 125
10 2412.80 25 13.71 2137 7 136
11 2144.00 25 13.84 1937 7 139
12 2097.70 25 13.74 1894 8 138
13 1941.90 25 13.89 1787 8 140
14 1846.30 25 13.85 1709 8 141
15 1664.70 25 13.99 1580 8 141
16 1569.40 25 13.96 1518 8 138
17 926.00 25 14.39 1044 7 139
18 827.70 25 14.31 971 7 137
19 720.80 25 14.34 896 7 138
20 604.70 25 14.39 813 7 137
21 484.10 25 14.45 721 7 137
22 350.60 25 14.55 618 7 135
23 217.30 25 14.61 525 7 134
24 104.60 25 14.65 459 7 129
25 48.80 25 14.58 401 7 122
26 22.60 25 14.58 373 7 120
27 -0.20 25 14.54 354 7 116
28 -0.20 429 13.82 331 8 189

Cycle 410 GMT 2/ 3/2013 19:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.00 10 14.60 471 7 60
2 4001.40 21 13.06 3242 6 101
3 3938.10 3 13.96 3166 6 113
4 3801.30 40 12.57 3143 6 103
5 3690.40 25 13.16 3049 6 112
6 3504.40 25 13.28 2930 6 116
7 3380.70 25 13.35 2808 6 116
8 2915.30 25 13.55 2513 6 120
9 2651.50 25 13.62 2335 7 131
10 2463.30 25 13.70 2168 7 136
11 1949.50 25 13.95 1801 7 140
12 1887.40 25 13.84 1763 8 139
13 1810.40 25 13.85 1694 8 141
14 1716.80 25 13.89 1616 8 140
15 1627.50 25 13.88 1582 8 139
16 1128.60 25 14.32 1197 7 140
17 923.80 25 14.38 1047 7 139
18 816.90 25 14.26 980 7 138
19 706.10 25 14.35 897 7 138
20 598.10 25 14.38 821 7 137
21 480.80 25 14.42 747 7 137
22 350.50 25 14.54 647 7 135
23 216.30 25 14.54 566 7 132
24 95.70 25 14.65 466 7 124
25 41.90 25 14.62 413 7 120
26 2.60 25 14.61 385 7 116
27 0.00 25 14.48 394 7 119
28 0.00 421 13.80 346 7 194

Cycle 409 GMT 27/ 2/2013 20:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 10 14.57 495 7 59
2 4000.80 14 13.20 3289 6 100
3 3938.20 2 13.93 3202 6 110
4 3908.10 40 12.49 3219 6 104
5 3811.10 25 13.16 3106 6 112
6 3755.90 25 13.12 3068 6 111
7 3430.00 25 13.39 2906 6 113
8 2957.00 25 13.57 2561 6 126
9 2768.30 25 13.62 2399 7 122
10 2431.00 25 13.78 2159 7 134
11 2234.20 25 13.77 2030 8 136
12 1959.90 25 13.91 1828 7 139
13 1883.80 25 13.78 1787 8 141
14 1595.90 25 14.11 1544 7 142
15 1507.30 25 13.97 1497 8 142
16 1120.70 25 14.30 1201 7 141
17 915.90 25 14.36 1063 7 139
18 804.30 25 14.29 966 7 139
19 689.80 25 14.35 875 7 138
20 573.20 25 14.45 780 7 137
21 448.90 25 14.52 697 7 136
22 307.80 25 14.60 592 7 135
23 175.00 25 14.67 488 7 130
24 78.70 25 14.67 420 7 124
25 33.90 25 14.67 387 7 121
26 14.60 25 14.59 363 7 120
27 0.00 453 13.87 324 8 228

Cycle 408 GMT 24/ 2/2013 21:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.60 10 14.59 485 7 59
2 4000.40 14 13.28 3261 6 102
3 3942.80 3 13.87 3202 6 111
4 3873.30 40 12.58 3155 6 94
5 3772.90 25 13.20 3104 6 112
6 3592.10 25 13.32 2985 6 119
7 3342.70 25 13.47 2792 6 113
8 2885.20 25 13.65 2454 6 123
9 2759.90 25 13.64 2366 7 127
10 2310.40 25 13.87 2025 7 137
11 2027.80 25 13.88 1873 7 140
12 1961.60 25 13.77 1832 8 141
13 1877.80 25 13.84 1756 8 141
14 1782.70 25 13.84 1699 8 141
15 1300.40 25 14.25 1320 7 141
16 1105.60 25 14.29 1187 7 140
17 999.90 25 14.24 1106 7 140
18 888.30 25 14.30 1025 7 140
19 776.80 25 14.29 954 7 139
20 651.60 25 14.40 849 7 139
21 524.10 25 14.51 744 7 138
22 390.40 25 14.53 659 7 137
23 257.60 25 14.62 599 7 134
24 118.60 25 14.58 528 7 126
25 55.40 25 14.63 428 7 122
26 24.40 25 14.61 404 7 120
27 10.30 25 14.46 380 7 118
28 -0.30 25 14.46 368 8 117
29 -0.40 395 13.83 329 8 205

Cycle 407 GMT 21/ 2/2013 22: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.30 10 14.64 471 7 59
2 4000.50 11 13.34 3318 6 100
3 3954.30 3 13.87 3213 6 105
4 3944.20 40 12.55 3248 6 102
5 3853.60 25 13.19 3185 6 109
6 3798.60 25 13.12 3116 6 110
7 3292.00 25 13.50 2775 6 121
8 3095.00 25 13.54 2635 6 127
9 2904.90 25 13.59 2504 7 121
10 2478.20 25 13.87 2189 7 137
11 2208.90 25 13.90 1999 7 139
12 1982.10 25 13.97 1856 8 137
13 1901.30 25 13.87 1759 8 140
14 1808.90 25 13.89 1694 8 139
15 1516.00 25 14.14 1487 7 142
16 1206.60 25 14.24 1275 7 141
17 1120.10 25 14.20 1182 7 140
18 896.00 25 14.39 1030 7 138
19 787.70 25 14.33 961 7 139
20 664.50 25 14.40 861 7 138
21 542.70 25 14.42 785 7 138
22 414.70 25 14.51 678 7 136
23 278.10 25 14.59 575 7 135
24 142.50 25 14.67 485 7 128
25 60.40 25 14.72 423 7 123
26 -0.20 25 14.73 382 7 126
27 -0.20 455 13.91 325 7 219

Cycle 406 GMT 18/ 2/2013 23: 2: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.30 10 14.59 466 7 58
2 4000.90 17 13.31 3224 6 95
3 3937.20 3 13.96 3261 6 102
4 3859.20 40 12.72 3154 6 95
5 3739.90 25 13.27 3071 6 114
6 3624.90 25 13.32 3011 6 115
7 3566.80 25 13.26 2918 6 114
8 2894.10 25 13.70 2466 6 127
9 2569.30 25 13.87 2201 7 135
10 2241.90 25 13.88 2051 7 135
11 1970.70 25 14.03 1806 7 141
12 1896.80 25 13.84 1766 8 140
13 1825.60 25 13.89 1697 8 141
14 1743.20 25 13.97 1625 8 141
15 1544.10 25 14.13 1483 7 139
16 1048.10 25 14.43 1123 7 140
17 947.90 25 14.29 1056 7 139
18 838.10 25 14.38 966 7 139
19 721.30 25 14.42 885 7 139
20 604.10 25 14.50 804 7 139
21 479.90 25 14.54 742 7 138
22 337.90 25 14.63 630 7 136
23 201.50 25 14.65 520 7 132
24 90.20 25 14.70 459 7 126
25 40.40 25 14.63 399 7 122
26 17.10 25 14.61 370 7 120
27 1.40 445 13.88 335 9 208

Cycle 405 GMT 15/ 2/2013 23:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.10 10 14.64 471 7 59
2 4000.40 12 13.43 3251 6 97
3 3932.80 2 13.93 3214 6 108
4 3916.60 40 12.75 3191 6 103
5 3813.60 25 13.25 3135 6 111
6 3754.70 25 13.18 3101 6 112
7 3294.50 25 13.56 2739 6 121
8 2984.40 25 13.66 2540 6 128
9 2666.30 25 13.77 2311 7 132
10 2555.90 25 13.75 2228 7 130
11 1997.60 25 14.00 1859 7 135
12 1917.10 25 13.88 1780 8 141
13 1836.80 25 13.91 1709 8 142
14 1750.80 25 13.97 1640 8 141
15 1658.60 25 14.00 1575 8 140
16 956.30 25 14.48 1078 7 140
17 866.60 25 14.34 987 7 139
18 747.60 25 14.41 911 7 139
19 643.60 25 14.43 856 6 136
20 516.60 25 14.54 744 6 133
21 395.90 25 14.59 670 6 131
22 270.50 25 14.59 590 6 130
23 137.40 25 14.75 471 6 128
24 63.20 25 14.76 401 7 125
25 29.80 25 14.64 370 7 122
26 12.50 25 14.59 352 7 120
27 -0.10 25 14.52 349 7 119
28 -0.20 418 13.91 319 8 192

Cycle 404 GMT 13/ 2/2013 0: 5: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.40 10 14.62 504 7 60
2 4001.00 12 13.48 3280 6 102
3 3942.50 3 14.09 3154 6 102
4 3869.90 51 12.74 3135 6 104
5 3757.50 25 13.34 3063 6 110
6 3379.30 25 13.57 2794 6 123
7 3253.20 25 13.53 2716 6 126
8 2929.50 25 13.67 2518 6 126
9 2517.00 25 13.84 2232 7 134
10 2254.50 25 13.94 2009 7 137
11 1971.00 25 14.02 1825 7 140
12 1885.80 25 13.92 1756 8 139
13 1802.10 25 13.96 1685 8 141
14 1521.90 25 14.18 1494 7 140
15 1429.20 25 14.13 1394 7 140
16 1101.10 25 14.39 1192 7 141
17 988.50 25 14.28 1130 7 140
18 863.80 25 14.35 1030 7 141
19 748.50 25 14.33 980 7 140
20 631.00 25 14.44 885 7 138
21 497.40 25 14.48 790 6 133
22 372.80 25 14.59 685 6 131
23 230.80 25 14.61 573 6 130
24 40.60 25 14.85 387 7 123
25 17.10 25 14.71 370 7 122
26 -0.10 25 14.59 361 7 113
27 -0.10 434 13.95 316 7 212

Cycle 403 GMT 11/ 2/2013 1:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.90 10 14.69 466 7 59
2 4000.50 8 13.63 3285 6 102
3 3953.10 3 14.09 3261 6 107
4 3917.80 51 12.69 3192 6 102
5 3802.80 25 13.33 3097 6 114
6 3521.60 25 13.50 2927 6 117
7 3207.70 25 13.62 2713 6 124
8 2748.20 25 13.78 2375 6 125
9 2632.20 25 13.71 2313 7 131
10 2165.00 25 13.97 1971 7 137
11 2106.00 25 13.85 1904 8 140
12 1954.10 25 14.01 1804 8 141
13 1876.60 25 13.90 1749 8 140
14 1583.00 25 14.16 1537 7 141
15 1492.60 25 14.12 1442 7 140
16 1181.50 25 14.35 1242 7 140
17 974.00 25 14.36 1080 7 140
18 854.00 25 14.36 980 6 138
19 730.10 25 14.44 877 6 136
20 610.50 25 14.53 778 6 132
21 480.10 25 14.57 716 6 133
22 344.40 25 14.62 604 6 131
23 210.10 25 14.74 499 6 129
24 92.40 25 14.80 416 7 126
25 37.50 25 14.74 377 7 122
26 -0.10 461 13.98 344 6 225

Cycle 402 GMT 9/ 2/2013 2:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.50 10 14.72 471 7 59
2 4000.20 8 13.77 3231 6 101
3 3950.20 3 13.96 3249 6 108
4 3875.80 51 12.75 3166 6 105
5 3691.40 25 13.43 3030 6 112
6 3506.70 25 13.45 2942 6 122
7 3046.30 25 13.70 2609 6 126
8 2852.10 25 13.68 2459 6 126
9 2794.60 25 13.60 2392 7 126
10 2215.10 25 14.03 1978 7 138
11 1950.60 25 14.05 1840 7 138
12 1871.00 25 13.95 1754 8 136
13 1780.00 25 13.99 1673 8 140
14 1581.30 25 14.15 1530 7 141
15 1490.70 25 14.07 1475 7 142
16 1177.60 25 14.39 1225 7 140
17 954.30 25 14.43 1051 6 138
18 841.90 25 14.37 983 6 137
19 720.30 25 14.47 859 6 135
20 603.30 25 14.52 789 6 133
21 461.70 25 14.59 692 6 133
22 337.00 25 14.66 594 6 131
23 196.00 25 14.71 504 7 129
24 85.00 25 14.77 442 7 125
25 34.80 25 14.74 396 7 121
26 -0.20 25 14.67 380 8 120
27 0.00 434 14.01 314 7 226

Cycle 401 GMT 7/ 2/2013 3:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.90 10 14.69 475 7 61
2 4000.70 11 13.58 3275 6 102
3 3947.60 3 13.90 3285 6 112
4 3847.00 81 12.48 3118 6 108
5 3443.00 31 13.43 2926 6 119
6 2979.90 31 13.63 2563 6 126
7 2901.20 31 13.53 2509 7 128
8 2263.50 31 13.90 2063 7 138
9 1966.90 31 13.95 1860 7 140
10 1830.70 31 13.89 1749 8 142
11 1703.30 31 13.99 1624 8 141
12 1409.40 31 14.16 1426 7 143
13 962.10 31 14.42 1080 6 139
14 820.90 31 14.39 983 6 138
15 646.60 31 14.45 854 6 136
16 480.60 31 14.53 767 6 132
17 303.80 31 14.71 624 6 132
18 144.90 31 14.76 511 7 129
19 69.00 31 14.73 459 7 126
20 34.40 31 14.61 442 8 123
21 -0.10 31 14.59 420 7 119
22 0.00 437 13.90 344 8 222

Cycle 400 GMT 5/ 2/2013 16:59: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.80 10 14.69 476 7 60
2 3991.70 7 13.87 3301 6 100
3 3931.10 3 14.12 3213 6 107
4 3899.30 81 12.48 3164 6 108
5 3611.30 31 13.42 2999 6 111
6 3318.30 31 13.51 2769 6 121
7 2779.20 31 13.73 2400 7 131
8 2384.60 31 13.85 2100 7 136
9 1945.20 31 14.04 1781 7 137
10 1855.80 31 13.93 1715 8 139
11 1591.20 31 14.13 1521 8 141
12 1158.50 31 14.37 1192 7 141
13 1014.90 31 14.33 1096 7 139
14 877.10 31 14.38 1003 6 138
15 722.30 31 14.44 894 6 135
16 539.30 31 14.56 759 6 133
17 354.10 31 14.63 622 6 132
18 157.70 31 14.80 485 7 129
19 70.80 31 14.77 408 7 126
20 30.40 31 14.68 372 7 124
21 14.80 31 14.57 364 8 122
22 0.50 31 14.43 378 8 118
23 -0.20 416 13.95 322 9 229

Cycle 399 GMT 4/ 2/2013 6:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.70 11 14.75 456 7 58
2 3987.30 6 13.85 3277 6 103
3 3948.50 4 14.02 3249 6 107
4 3906.20 81 12.46 3193 6 108
5 3621.40 31 13.40 3019 6 120
6 3444.20 31 13.41 2888 6 123
7 2667.40 31 13.73 2366 6 132
8 2298.10 31 13.88 2061 7 135
9 1985.00 31 13.97 1854 7 142
10 1725.30 31 14.07 1650 8 141
11 1623.70 31 14.02 1565 8 140
12 1355.20 31 14.24 1358 7 140
13 1076.80 31 14.37 1156 6 139
14 904.00 31 14.37 1025 6 138
15 732.10 31 14.41 930 6 136
16 550.20 31 14.55 775 6 132
17 368.20 31 14.68 634 6 131
18 185.90 31 14.78 497 7 129
19 87.30 31 14.74 442 7 127
20 40.10 31 14.75 372 7 123
21 17.20 31 14.65 362 8 121
22 1.50 448 14.01 324 8 207

Cycle 398 GMT 2/ 2/2013 19:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.90 10 14.77 475 7 58
2 3997.00 7 13.91 3277 6 97
3 3946.20 3 14.06 3273 6 105
4 3869.30 81 12.47 3200 6 109
5 3584.70 31 13.44 2983 6 120
6 3274.50 31 13.53 2755 6 119
7 2756.00 31 13.72 2408 6 132
8 2439.70 31 13.82 2178 7 137
9 1941.20 31 14.01 1822 7 139
10 1808.60 31 13.97 1729 8 142
11 1682.50 31 13.93 1642 8 142
12 1404.60 31 14.15 1454 7 141
13 967.70 31 14.41 1102 6 138
14 843.60 31 14.36 1017 6 136
15 664.40 31 14.47 880 6 135
16 494.40 31 14.60 735 6 131
17 317.30 31 14.70 600 6 130
18 146.30 31 14.75 503 7 127
19 70.40 31 14.74 440 7 124
20 31.10 31 14.66 400 7 121
21 -0.10 31 14.64 380 7 117
22 0.00 448 13.99 332 7 216

Cycle 397 GMT 1/ 2/2013 8: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.30 10 14.77 456 7 53
2 3958.50 4 14.15 3226 6 106
3 3923.20 1 14.25 3238 6 97
4 3908.30 81 12.47 3199 6 101
5 3593.80 31 13.36 3043 6 113
6 2981.90 31 13.67 2575 6 124
7 2800.20 31 13.67 2432 7 130
8 2168.50 31 13.95 1977 7 135
9 2092.40 31 13.78 1963 8 140
10 1971.20 31 13.85 1868 8 142
11 1848.90 31 13.85 1781 8 140
12 1715.30 31 13.95 1676 8 140
13 1403.20 31 14.22 1410 6 138
14 902.70 31 14.47 1057 6 137
15 735.20 31 14.41 952 6 137
16 553.60 31 14.54 808 6 133
17 359.80 31 14.64 664 6 131
18 172.80 31 14.75 553 7 128
19 92.50 31 14.73 465 7 125
20 44.90 31 14.69 422 7 122
21 18.90 31 14.59 398 7 119
22 0.10 31 14.63 382 7 119
23 0.20 421 13.98 339 7 238

Cycle 396 GMT 30/ 1/2013 20:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.00 200 14.15 471 6 84
2 500.70 42 14.47 794 6 98
3 428.30 2 15.03 749 7 106
4 384.60 81 14.44 647 6 109
5 172.40 31 14.88 495 6 113
6 113.40 31 14.75 469 7 111
7 69.60 31 14.75 432 7 110
8 42.20 31 14.67 408 7 109
9 24.00 31 14.62 392 7 108
10 11.90 31 14.51 392 7 107
11 -0.20 31 14.51 376 7 104
12 -0.40 461 14.01 337 8 205

Cycle 395 GMT 30/ 1/2013 13:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.10 10 14.83 461 7 48
2 3895.00 81 12.44 3231 6 108
3 3482.50 31 13.45 2956 6 123
4 3002.10 31 13.65 2582 6 128
5 2638.50 31 13.76 2328 6 133
6 2245.20 31 13.89 2059 7 137
7 1973.60 31 13.97 1858 7 140
8 1842.70 31 13.92 1733 8 142
9 1705.80 31 13.96 1646 8 143
10 1417.40 31 14.17 1450 7 139
11 1118.30 31 14.32 1227 6 139
12 961.70 31 14.29 1106 6 137
13 795.10 31 14.38 1001 6 136
14 623.10 31 14.47 854 6 132
15 431.90 31 14.56 727 6 131
16 236.10 31 14.69 586 7 129
17 108.60 31 14.74 487 7 126
18 44.70 31 14.72 424 7 123
19 1.00 481 14.04 340 7 230

Cycle 390 GMT 28/ 1/2013 20:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.30 10 14.77 490 7 52
2 2047.50 170 12.89 1864 6 112
3 1721.90 81 13.57 1644 6 130
4 1479.80 31 14.10 1483 6 135
5 1356.50 31 14.14 1382 6 134
6 921.60 31 14.44 1071 6 135
7 793.30 31 14.40 981 7 136
8 624.40 31 14.48 868 7 135
9 456.20 31 14.62 739 7 133
10 276.90 31 14.68 612 7 131
11 133.00 31 14.78 535 7 127
12 62.80 31 14.63 491 7 124
13 27.10 31 14.60 436 7 122
14 0.00 31 14.55 394 7 117
15 0.00 450 13.95 351 8 234

Cycle 389 GMT 28/ 1/2013 6:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.20 191 14.23 438 7 82
2 502.60 78 14.28 751 6 96
3 200.40 81 14.56 544 7 108
4 85.60 31 14.86 474 7 108
5 62.10 31 14.76 432 7 107
6 33.50 31 14.66 420 7 106
7 15.50 31 14.58 398 8 105
8 1.00 500 14.09 338 11 121

Cycle 388 GMT 28/ 1/2013 0:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.40 46 14.52 478 7 69
2 3002.90 50 13.25 2581 6 114
3 2694.20 81 12.99 2381 6 122
4 2163.70 30 13.89 2035 6 136
5 1955.30 31 13.96 1824 7 139
6 1832.60 31 13.89 1755 7 140
7 1589.50 31 14.07 1600 6 139
8 1036.50 31 14.40 1166 6 137
9 894.30 31 14.29 1083 6 137
10 743.60 31 14.42 946 7 136
11 583.60 31 14.49 840 7 134
12 408.70 31 14.62 709 6 130
13 217.60 31 14.69 581 7 128
14 99.50 31 14.80 481 7 126
15 52.60 31 14.71 436 7 123
16 -0.20 31 14.72 408 8 117
17 -0.10 471 14.02 339 7 237

Cycle 387 GMT 27/ 1/2013 0:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.10 74 14.36 485 7 76
2 2004.70 86 13.30 1875 6 116
3 1667.20 81 13.58 1640 6 133
4 1540.00 20 14.15 1556 7 133
5 1480.40 20 14.13 1508 7 135
6 1411.40 20 14.15 1436 7 132
7 1187.00 20 14.41 1279 6 135
8 1037.60 20 14.44 1169 6 136
9 961.60 20 14.35 1109 7 136
10 873.40 20 14.39 1047 7 135
11 782.70 20 14.42 984 6 133
12 688.10 20 14.48 919 6 133
13 585.30 20 14.48 853 7 133
14 484.60 20 14.56 776 7 132
15 270.60 20 14.80 609 7 129
16 171.70 20 14.74 553 7 127
17 80.00 20 14.84 479 7 125
18 40.30 20 14.76 443 7 122
19 18.90 20 14.69 407 7 120
20 -0.20 20 14.68 416 8 115
21 -0.10 447 14.01 349 9 186

Cycle 386 GMT 26/ 1/2013 9:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 99 14.28 521 7 77
2 2000.40 22 13.97 1949 6 119
3 2012.20 9 14.15 1958 6 125
4 1978.60 81 13.30 1895 6 125
5 1860.20 20 14.00 1823 7 132
6 1794.10 20 13.97 1773 7 131
7 1565.50 20 14.26 1600 6 133
8 1497.70 20 14.07 1588 6 132
9 1183.70 20 14.42 1332 6 136
10 960.60 20 14.47 1157 6 137
11 870.80 20 14.38 1118 7 130
12 785.40 20 14.37 1062 6 133
13 710.50 20 14.47 961 6 134
14 611.20 20 14.48 904 7 133
15 518.70 20 14.48 847 7 133
16 420.70 20 14.56 764 7 131
17 331.40 20 14.67 669 7 130
18 224.90 20 14.71 601 7 128
19 126.40 20 14.80 532 7 126
20 57.50 20 14.80 473 7 123
21 24.30 20 14.69 467 7 120
22 -0.30 20 14.66 449 7 119
23 -0.30 455 13.96 374 7 171

Cycle 385 GMT 25/ 1/2013 18:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.10 161 14.20 500 7 80
2 1001.10 42 14.17 1157 6 108
3 969.90 6 14.57 1166 6 115
4 896.50 80 13.97 1082 6 119
5 838.30 20 14.33 1080 6 119
6 806.10 20 14.26 1035 7 120
7 770.70 20 14.26 1014 7 120
8 734.80 20 14.22 999 7 121
9 698.80 20 14.25 973 7 122
10 661.50 20 14.27 961 7 121
11 620.20 20 14.31 907 7 122
12 486.30 20 14.49 847 7 124
13 446.50 20 14.45 776 7 124
14 405.00 20 14.49 737 8 124
15 184.50 20 14.81 603 7 123
16 95.40 20 14.82 514 7 121
17 22.50 20 14.80 466 7 117
18 -0.30 20 14.72 425 7 111
19 -0.30 434 14.02 378 9 185

Cycle 384 GMT 25/ 1/2013 11:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.00 155 14.21 498 7 84
2 1003.60 54 14.08 1154 6 109
3 962.40 6 14.66 1142 6 114
4 872.80 81 13.96 1095 6 118
5 809.80 20 14.39 1029 6 120
6 779.10 20 14.29 1026 7 120
7 745.90 20 14.28 993 7 121
8 709.60 20 14.26 987 7 121
9 670.10 20 14.27 949 7 122
10 628.50 20 14.30 922 7 123
11 587.30 20 14.37 898 7 123
12 547.40 20 14.32 898 7 124
13 507.40 20 14.34 839 8 124
14 464.80 20 14.39 779 8 124
15 331.30 20 14.70 684 7 124
16 152.20 20 14.73 603 7 121
17 60.60 20 14.82 502 7 119
18 -0.40 20 14.81 467 8 115
19 -0.20 426 14.03 393 7 187

Cycle 383 GMT 25/ 1/2013 3:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 179 14.19 514 7 82
2 501.20 5 14.49 795 6 92
3 503.70 1 14.74 856 6 98
4 465.60 1 14.26 779 6 103
5 433.60 2 14.44 758 7 104
6 418.90 2 14.39 761 7 105
7 403.20 2 14.30 768 7 105
8 385.80 2 14.34 758 7 106
9 366.70 2 14.33 751 7 106
10 346.80 2 14.31 754 7 107
11 327.20 2 14.28 758 7 108
12 307.60 2 14.33 713 7 108
13 286.80 2 14.33 690 7 108
14 79.00 2 14.81 560 7 109
15 -0.40 2 14.80 503 7 105
16 -0.30 2 14.56 476 7 107
17 -0.30 198 14.23 403 102 108

Cycle 382 GMT 24/ 1/2013 23:34: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.70 191 14.28 497 7 73
2 501.20 18 14.52 867 7 87
3 494.90 1 14.68 880 7 91
4 473.50 2 14.18 833 7 94
5 443.10 2 14.46 791 7 97
6 429.20 2 14.36 795 7 97
7 414.00 2 14.38 802 7 98
8 397.30 2 14.34 815 7 99
9 379.50 2 14.34 791 7 100
10 360.90 2 14.39 741 7 101
11 341.20 2 14.38 734 7 100
12 320.60 2 14.39 696 7 101
13 122.50 2 14.89 571 7 104
14 104.40 2 14.66 567 7 103
15 83.90 2 14.54 523 7 103
16 0.30 2 14.87 476 7 106
17 0.30 199 14.27 438 98 104

Cycle 381 GMT 24/ 1/2013 19:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 53.50 222 14.22 515 7 72
2 123.00 48 14.55 578 7 74
3 124.50 2 14.87 583 7 74
4 118.20 81 14.54 527 7 80
5 107.30 20 14.55 538 7 81
6 103.10 20 14.48 526 7 81
7 98.40 20 14.40 529 7 81
8 93.00 20 14.44 502 7 81
9 87.00 20 14.41 514 7 81
10 80.70 20 14.39 502 7 81
11 73.80 20 14.40 496 7 81
12 36.90 20 14.75 469 7 82
13 29.90 20 14.56 467 7 82
14 -0.40 280 14.31 407 7 89

Cycle 380 GMT 24/ 1/2013 18:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 56.40 241 14.22 512 7 72
2 120.80 21 14.78 555 7 75
3 123.40 2 14.99 535 7 75
4 120.80 81 14.50 544 7 80
5 109.10 20 14.51 541 7 81
6 104.10 20 14.44 544 7 81
7 98.40 20 14.36 541 7 81
8 92.60 20 14.37 517 7 82
9 86.50 20 14.40 499 7 81
10 80.10 20 14.38 499 7 82
11 73.40 20 14.35 496 7 82
12 51.60 20 14.59 496 7 82
13 7.60 20 14.77 484 7 83
14 0.20 5 14.71 464 7 92
15 0.20 196 14.25 447 78 86