SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8243 WMO= 5904343


Cycle 308 GMT 11/ 9/2021 3:59: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.68 41 10.47 428 6 6
2 1025.12 80 6.25 1802 6 6
3 822.04 51 7.20 1528 6 6
4 170.68 51 9.88 544 6 8
5 0.12 180 10.75 263 6 25

Cycle 307 GMT 1/ 9/2021 10:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.04 41 10.47 428 6 6
2 1019.96 80 6.35 1795 6 6
3 825.20 51 7.22 1530 6 6
4 162.08 51 9.93 533 6 8
5 0.12 180 10.73 268 6 19

Cycle 306 GMT 22/ 8/2021 16:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.32 41 10.47 428 6 6
2 1011.92 80 6.56 1779 6 6
3 613.52 51 8.11 1232 6 6
4 112.00 51 10.34 434 6 8
5 0.12 181 10.79 262 6 22

Cycle 305 GMT 12/ 8/2021 23:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.76 41 10.60 410 6 6
2 1129.24 46 6.47 1988 6 6
3 1337.56 100 5.89 2272 6 6
4 1325.84 80 5.80 2251 6 6
5 655.56 51 8.20 1291 6 6
6 112.60 51 10.36 437 6 8
7 0.88 180 10.80 263 6 23

Cycle 304 GMT 11/ 8/2021 20:35:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.80 40 10.54 428 6 6
2 1021.76 80 6.80 1799 6 6
3 605.08 51 8.38 1217 6 6
4 112.96 51 10.38 436 6 8
5 0.20 180 10.81 265 6 20

Cycle 303 GMT 2/ 8/2021 3: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.28 40 10.60 428 6 6
2 1008.12 80 6.97 1785 6 6
3 587.92 51 8.53 1195 6 6
4 93.36 51 10.47 405 6 8
5 0.04 181 10.81 268 6 22

Cycle 302 GMT 23/ 7/2021 9:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.64 40 10.73 410 6 6
2 1007.36 80 7.11 1796 6 6
3 399.20 51 9.28 911 6 7
4 90.84 51 10.50 402 6 9
5 0.08 181 10.84 266 6 23

Cycle 301 GMT 13/ 7/2021 15:34: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.72 41 10.66 428 6 6
2 1131.68 30 6.76 1983 6 6
3 1684.60 100 4.84 2851 6 6
4 1684.52 80 4.78 2630 6 6
5 1681.24 51 4.86 2819 6 6
6 1682.52 51 4.87 2874 6 6
7 1682.72 51 4.91 2896 6 6
8 1682.44 51 4.91 2923 6 6
9 1684.48 51 4.97 2926 6 6
10 1675.36 51 5.17 2857 6 6
11 1597.60 51 5.57 2693 6 6
12 1454.16 50 6.18 2442 6 6
13 1278.36 50 6.66 2184 6 6
14 869.44 50 7.89 1605 6 6
15 130.64 50 10.45 466 6 8
16 0.12 180 10.88 264 6 19

Cycle 300 GMT 12/ 7/2021 7:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.48 40 10.54 428 6 6
2 1008.92 80 7.06 1799 6 6
3 574.88 51 8.61 1179 6 6
4 89.56 51 10.49 399 6 8
5 0.08 181 10.83 262 6 20

Cycle 299 GMT 2/ 7/2021 14:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 40 10.73 410 6 6
2 1014.48 80 7.18 1804 6 6
3 593.12 51 8.68 1205 6 7
4 93.04 51 10.53 405 6 9
5 0.04 181 10.84 264 6 18

Cycle 298 GMT 22/ 6/2021 21: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.04 40 10.73 446 6 6
2 1023.32 80 7.38 1821 6 6
3 398.76 51 9.43 921 6 8
4 88.04 51 10.54 402 6 9
5 0.16 180 10.86 265 6 19

Cycle 297 GMT 13/ 6/2021 3:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.32 40 10.66 428 6 6
2 1020.48 1 7.73 1839 6 6
3 1121.00 30 7.51 1953 6 6
4 1271.68 100 6.90 2177 6 6
5 1259.08 80 6.75 2144 6 6
6 178.20 51 10.30 553 6 8
7 44.36 51 10.75 323 6 9
8 0.04 181 10.89 265 6 25

Cycle 296 GMT 12/ 6/2021 0:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.52 38 10.73 410 6 6
2 1063.88 2 8.11 1875 6 6
3 1038.88 1 8.37 1857 6 6
4 1043.96 80 7.44 1843 6 6
5 820.04 51 8.27 1530 6 6
6 133.28 51 10.41 477 6 9
7 0.16 180 10.87 264 6 24

Cycle 295 GMT 2/ 6/2021 7:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 37 11.11 428 6 6
2 1038.80 3 9.00 1857 6 6
3 1006.32 80 8.12 1806 6 6
4 535.44 51 9.18 1116 6 7
5 68.84 51 10.75 359 6 9
6 0.08 181 10.91 260 6 18

Cycle 294 GMT 23/ 5/2021 14:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.76 36 11.43 446 6 6
2 1040.52 1 9.58 1857 6 6
3 1027.28 60 8.36 1837 6 6
4 804.68 51 8.96 1527 6 6
5 128.16 51 10.83 469 6 9
6 0.08 181 11.17 263 6 20

Cycle 293 GMT 13/ 5/2021 20:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.88 31 11.75 428 6 6
2 1000.68 4 9.07 1821 6 6
3 1028.36 3 8.81 1875 6 6
4 1049.72 1 8.30 1928 6 6
5 1027.56 1 8.43 1892 6 6
6 1123.64 15 8.17 1981 6 6
7 1948.64 100 4.87 2800 6 6
8 1948.24 61 4.79 2551 6 6
9 1930.60 51 5.41 3202 6 6
10 1855.08 51 5.91 3136 6 6
11 1717.24 51 6.68 2871 6 6
12 1541.72 51 7.29 2609 6 6
13 1089.56 51 8.48 1930 6 6
14 355.60 50 10.23 864 6 9
15 52.92 50 11.22 342 6 10
16 0.12 181 11.27 270 6 30

Cycle 292 GMT 12/ 5/2021 15:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.08 30 12.00 428 6 6
2 1043.12 3 9.00 1875 6 6
3 1110.36 3 8.75 1946 6 6
4 1054.16 1 8.69 1910 6 6
5 1056.56 60 5.06 1827 6 6
6 926.44 51 7.43 1671 6 6
7 514.60 51 9.45 1090 6 7
8 114.68 51 11.35 455 6 10
9 0.12 181 11.77 275 6 25

Cycle 291 GMT 2/ 5/2021 22: 3: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.12 32 12.25 446 6 6
2 1027.88 3 10.15 1910 6 6
3 1021.08 1 9.58 1892 6 6
4 1016.08 60 6.71 1792 6 6
5 827.28 51 8.59 1549 6 6
6 170.36 51 11.37 558 6 10
7 0.16 181 12.05 277 6 25

Cycle 290 GMT 23/ 4/2021 4:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.24 30 13.34 428 6 6
2 1061.00 2 11.37 1964 6 6
3 1021.48 1 11.11 1892 6 6
4 1147.32 10 8.65 2044 6 6
5 1201.08 180 7.09 2076 6 6
6 1195.64 66 6.10 2042 6 6
7 1174.44 29 7.39 2047 6 6
8 105.20 41 11.93 442 6 11
9 0.04 181 12.20 280 6 27

Cycle 289 GMT 13/ 4/2021 10:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.68 30 13.97 446 6 6
2 1019.04 1 10.79 1910 6 6
3 1112.56 10 10.85 2048 6 6
4 1963.64 180 5.96 2994 6 6
5 1946.28 66 4.82 2467 6 6
6 1930.20 29 7.05 3184 6 6
7 1480.40 41 9.64 2537 6 6
8 812.64 41 10.87 1583 6 8
9 150.28 41 12.55 523 6 10
10 0.08 181 12.96 282 6 27

Cycle 288 GMT 12/ 4/2021 6:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.48 30 14.10 464 6 6
2 1138.96 10 4.70 1724 6 6
3 1205.72 180 4.61 1643 6 7
4 1222.76 66 4.76 1680 6 7
5 1234.44 28 7.83 2151 7 6
6 1339.76 40 8.18 2309 6 6
7 1203.92 40 9.11 2105 6 6
8 991.40 41 9.95 1816 6 6
9 155.28 41 13.06 539 6 10
10 29.12 41 13.61 323 6 11
11 0.16 180 13.45 287 6 48

Cycle 287 GMT 2/ 4/2021 11: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.52 29 14.29 446 6 6
2 1040.12 1 11.43 1946 6 6
3 1136.64 10 4.60 1389 6 6
4 1201.08 180 4.55 1679 6 7
5 1219.32 66 4.92 1782 6 7
6 1231.32 28 8.23 2154 7 6
7 1329.08 40 8.49 2291 6 6
8 1202.04 40 9.50 2122 6 6
9 770.68 41 11.29 1517 6 7
10 130.60 41 13.70 508 6 12
11 0.08 181 14.00 295 6 31

Cycle 286 GMT 23/ 3/2021 15:30: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.08 30 14.17 482 6 6
2 968.92 -1 14.17 482 6 6
3 1134.72 10 4.73 1806 6 6
4 1213.28 180 5.12 2071 6 6
5 1224.36 40 6.65 2121 6 6
6 1222.12 28 9.31 2160 6 6
7 1024.92 40 10.40 1874 6 6
8 311.40 41 13.19 828 6 12
9 49.84 41 14.11 376 6 13
10 0.08 181 14.15 301 6 53

Cycle 285 GMT 13/ 3/2021 20:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.52 30 14.29 446 6 6
2 1100.80 10 10.76 2008 6 6
3 1983.48 180 5.93 3116 6 6
4 1970.92 40 6.29 3135 6 6
5 1959.56 28 8.84 3268 6 6
6 1255.80 41 11.56 2252 6 7
7 283.20 41 13.64 787 6 13
8 19.92 41 14.32 327 6 13
9 0.08 181 14.30 303 6 53

Cycle 284 GMT 12/ 3/2021 16:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.16 30 14.29 464 6 6
2 1102.60 10 4.60 1328 6 6
3 1213.00 180 4.56 1698 6 7
4 1230.08 40 5.22 1876 6 7
5 1239.44 28 8.35 2166 7 6
6 1315.60 40 9.19 2297 6 6
7 1172.60 40 10.41 2093 6 6
8 522.48 41 12.79 1153 6 10
9 118.44 41 14.02 490 6 14
10 0.12 181 14.28 300 6 40

Cycle 283 GMT 2/ 3/2021 20:57: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.20 30 14.29 446 6 6
2 1129.88 10 4.63 1460 6 6
3 1207.12 180 4.64 1884 6 6
4 1225.60 40 5.69 2057 6 6
5 1235.00 28 8.87 2163 6 6
6 1294.20 40 9.76 2270 6 6
7 1134.80 40 10.83 2044 6 6
8 382.72 41 13.16 946 6 12
9 47.36 41 14.24 373 6 14
10 0.12 181 14.31 304 6 51

Cycle 282 GMT 21/ 2/2021 1:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.84 30 14.36 446 6 6
2 1123.60 10 4.71 1803 6 6
3 1199.16 150 6.11 2072 6 6
4 1202.80 40 7.32 2082 6 6
5 1189.40 28 9.55 2110 6 6
6 226.64 41 13.61 699 6 12
7 19.00 41 14.28 326 6 13
8 -0.08 180 14.34 304 6 61

Cycle 281 GMT 11/ 2/2021 7:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.84 30 14.23 482 6 6
2 1108.36 10 10.65 2008 6 6
3 1957.84 150 6.35 3244 6 6
4 1945.72 40 6.95 3255 6 6
5 1931.64 29 9.29 3211 6 6
6 986.16 41 12.45 1834 6 8
7 138.52 41 14.09 527 6 11
8 0.08 180 14.38 304 6 30

Cycle 280 GMT 10/ 2/2021 3:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.64 30 14.23 464 6 6
2 1111.16 10 4.60 1392 6 6
3 1214.76 150 4.69 1883 6 7
4 1230.00 40 5.53 2034 6 6
5 1239.68 29 8.82 2172 6 6
6 1296.24 41 10.14 2280 6 6
7 1112.48 41 11.15 2012 6 6
8 388.72 40 13.32 949 6 13
9 51.84 40 14.22 379 6 14
10 0.16 181 14.33 306 6 55

Cycle 279 GMT 31/ 1/2021 8: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.60 30 14.29 464 6 6
2 1121.28 10 4.66 1574 6 6
3 1198.16 150 4.94 2039 6 6
4 1209.80 40 6.64 2087 6 6
5 1214.64 28 9.29 2144 6 6
6 1082.88 40 11.09 1979 6 6
7 620.36 41 12.66 1308 6 10
8 70.68 41 14.14 408 6 13
9 0.08 181 14.34 305 6 47

Cycle 278 GMT 21/ 1/2021 13:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 30 14.23 464 6 6
2 1138.76 13 4.75 1951 6 6
3 1195.40 120 6.95 2064 6 6
4 1198.96 50 7.19 2063 6 6
5 1188.60 28 9.25 2094 6 6
6 214.84 41 13.71 678 6 12
7 0.20 181 14.33 305 6 33

Cycle 277 GMT 11/ 1/2021 19: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.20 30 14.23 464 6 6
2 1104.56 12 10.60 2010 6 6
3 1813.32 120 7.19 3014 6 6
4 1805.20 50 6.97 3038 6 6
5 1792.04 28 9.38 3017 6 6
6 473.88 41 13.40 1074 6 12
7 85.04 41 14.15 441 6 15
8 0.12 181 14.39 305 6 51

Cycle 276 GMT 10/ 1/2021 15:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.32 30 14.23 464 6 6
2 1129.28 13 4.65 1565 6 6
3 1207.60 120 4.99 2029 6 6
4 1218.48 50 5.62 2102 6 6
5 1224.12 28 8.86 2142 6 6
6 1134.64 40 10.98 2041 6 6
7 697.56 41 12.53 1425 6 10
8 104.60 41 14.08 466 6 12
9 0.16 181 14.36 300 6 39

Cycle 275 GMT 31/12/2020 21: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.40 30 14.29 464 6 6
2 1119.76 13 4.69 1716 6 6
3 1208.88 120 5.84 2087 6 6
4 1217.92 50 6.50 2087 6 6
5 1213.24 28 9.14 2125 6 6
6 554.40 41 12.84 1201 6 11
7 128.68 41 13.97 518 6 14
8 0.16 181 14.33 304 6 42

Cycle 274 GMT 22/12/2020 2:38: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.68 30 14.29 482 6 6
2 1120.08 13 5.35 1919 6 6
3 1203.48 120 7.18 2084 6 6
4 1206.16 50 7.48 2074 6 6
5 1194.92 28 9.47 2106 6 6
6 173.68 40 13.83 603 6 13
7 13.52 40 14.26 315 6 14
8 0.08 181 14.35 303 6 70

Cycle 273 GMT 12/12/2020 8:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.00 30 14.29 464 6 6
2 1209.88 12 10.39 2178 6 6
3 1789.96 120 7.27 3006 6 6
4 1780.12 50 7.34 2989 6 6
5 1766.08 28 9.56 2947 6 6
6 225.44 41 13.84 694 6 13
7 44.20 41 14.28 360 6 13
8 0.04 181 14.39 299 6 56

Cycle 272 GMT 11/12/2020 5: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.64 30 14.29 446 6 6
2 1102.08 13 4.65 1579 6 6
3 1206.80 120 5.20 2071 6 6
4 1215.24 50 6.27 2093 6 6
5 1216.20 28 9.07 2140 6 6
6 1050.84 40 11.37 1925 6 6
7 363.64 41 13.39 921 6 12
8 45.12 41 14.20 367 6 14
9 0.04 181 14.33 305 6 51

Cycle 271 GMT 1/12/2020 10:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 30 14.36 446 6 6
2 1123.32 13 4.69 1722 6 6
3 1206.92 120 6.00 2074 6 6
4 1214.56 50 6.78 2095 6 6
5 1208.08 28 9.17 2117 6 6
6 549.44 41 12.86 1209 6 10
7 68.08 41 14.18 403 6 13
8 0.16 181 14.36 302 6 40

Cycle 270 GMT 21/11/2020 15:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.88 30 14.29 464 6 6
2 1125.64 13 4.73 1916 6 6
3 1194.56 120 7.12 2069 6 6
4 1197.76 50 7.41 2074 6 6
5 1186.72 28 9.43 2092 6 6
6 183.12 41 13.84 621 6 13
7 15.96 41 14.22 325 6 14
8 0.04 181 14.32 307 6 66

Cycle 269 GMT 11/11/2020 21:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 30 14.23 482 6 6
2 1107.56 12 10.51 2010 6 6
3 1831.96 120 6.99 3051 6 6
4 1823.68 50 7.34 3095 6 6
5 1811.36 28 9.57 3050 6 6
6 513.36 41 13.38 1139 6 12
7 95.20 41 14.14 459 6 14
8 0.16 180 14.37 307 6 47

Cycle 268 GMT 10/11/2020 18:25: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.68 30 14.29 482 6 6
2 1123.12 13 4.66 1597 6 6
3 1208.56 120 5.49 2084 6 6
4 1216.52 50 6.54 2108 6 6
5 1211.68 28 9.18 2132 6 6
6 771.20 40 12.34 1531 6 9
7 121.84 41 14.03 503 6 13
8 -0.04 180 14.33 304 6 38

Cycle 267 GMT 1/11/2020 0: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.56 30 14.29 446 6 6
2 1125.88 13 4.69 1752 6 6
3 1202.84 120 6.32 2081 6 6
4 1208.52 50 7.02 2086 6 6
5 1200.40 28 9.25 2112 6 6
6 497.44 41 13.11 1129 6 12
7 90.72 41 14.07 453 6 14
8 0.16 181 14.32 305 6 46

Cycle 266 GMT 22/10/2020 5:50: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.04 30 14.36 446 6 6
2 1127.20 13 4.73 1904 6 6
3 1198.00 120 7.28 2076 6 6
4 1200.92 50 7.74 2086 6 6
5 1189.44 29 9.41 2114 6 6
6 160.24 40 13.92 584 6 13
7 0.08 181 14.34 303 6 32

Cycle 265 GMT 12/10/2020 11:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.88 30 14.29 464 6 6
2 1204.92 12 10.36 2156 6 6
3 1906.24 120 6.85 3199 6 6
4 1895.48 50 7.59 3159 6 6
5 1881.60 29 9.69 3133 6 6
6 578.64 40 13.31 1227 6 12
7 68.20 40 14.17 408 6 13
8 0.08 181 14.37 311 6 44

Cycle 264 GMT 11/10/2020 8:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.16 30 14.23 482 6 6
2 1100.40 13 4.68 1663 6 6
3 1236.16 120 5.81 2123 6 6
4 1245.60 50 6.96 2142 6 6
5 1240.32 28 9.41 2185 6 6
6 567.88 41 13.02 1244 6 11
7 72.32 41 14.13 423 6 13
8 0.12 181 14.34 308 6 41

Cycle 263 GMT 1/10/2020 13:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 30 14.23 446 6 6
2 1128.28 13 4.70 1767 6 6
3 1198.28 120 6.56 2072 6 6
4 1202.76 50 7.38 2083 6 6
5 1193.04 28 9.48 2115 6 6
6 229.68 40 13.73 706 6 13
7 41.76 40 14.20 363 6 13
8 0.04 180 14.33 310 6 55

Cycle 262 GMT 21/ 9/2020 19:14: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 30 14.36 446 6 6
2 1114.96 13 4.90 1871 6 6
3 1197.36 120 7.34 2077 6 6
4 1200.24 50 7.96 2091 6 6
5 1188.76 28 9.65 2104 6 6
6 160.36 41 13.89 585 6 13
7 0.12 181 14.31 311 6 33

Cycle 261 GMT 12/ 9/2020 1: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.92 30 14.23 464 6 6
2 1118.16 12 10.34 2035 6 6
3 1906.68 120 6.69 3168 6 6
4 1899.24 50 7.84 3165 6 6
5 1887.64 28 9.93 3134 6 6
6 596.76 41 13.28 1262 6 11
7 65.44 41 14.19 407 6 14
8 0.32 181 14.35 310 6 41

Cycle 260 GMT 10/ 9/2020 21:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 30 14.23 464 6 6
2 1115.52 120 11.82 344 6 6
3 1127.32 51 5.00 1946 6 6
4 1135.56 28 9.19 2028 6 6
5 1206.24 40 10.72 2151 6 6
6 1017.16 40 11.69 1880 6 7
7 154.08 41 13.90 573 6 13
8 30.36 41 14.20 348 6 14
9 0.08 181 14.31 311 6 66

Cycle 259 GMT 1/ 9/2020 2:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 30 14.10 482 6 6
2 1118.00 13 4.68 1698 6 6
3 1217.64 120 6.40 2108 6 6
4 1223.96 50 7.54 2107 6 6
5 1215.68 28 9.65 2142 6 6
6 262.12 40 13.71 759 6 13
7 44.76 40 14.17 381 6 14
8 0.00 181 14.29 314 6 57

Cycle 258 GMT 22/ 8/2020 8: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.76 30 14.23 464 6 6
2 1117.88 13 4.84 1862 6 6
3 1206.00 120 7.49 2095 6 6
4 1209.44 50 8.20 2108 6 6
5 1198.00 28 9.82 2123 6 6
6 157.20 40 13.92 591 6 14
7 0.12 181 14.31 313 6 34

Cycle 257 GMT 12/ 8/2020 13:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.72 30 14.23 464 6 6
2 1127.16 12 10.33 2049 6 6
3 1915.88 120 6.92 3184 6 6
4 1908.00 50 8.30 3157 6 6
5 1895.64 28 9.93 3165 6 6
6 347.32 41 13.67 908 6 13
7 55.60 41 14.15 397 6 14
8 0.08 181 14.33 314 6 53

Cycle 256 GMT 11/ 8/2020 10:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 30 14.23 482 6 6
2 1139.96 120 11.80 350 6 6
3 1152.48 51 5.20 1968 6 6
4 1160.64 28 9.49 2073 6 6
5 1211.12 40 11.10 2164 6 6
6 1031.36 40 11.93 1914 6 7
7 148.08 41 13.97 548 6 13
8 0.16 181 14.31 308 6 35

Cycle 255 GMT 1/ 8/2020 15:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.92 30 14.36 446 6 6
2 1133.04 13 4.69 1710 6 6
3 1199.20 120 6.87 2077 6 6
4 1203.56 51 7.78 2097 6 6
5 1193.40 35 9.60 2113 6 6
6 162.44 41 13.90 591 6 14
7 0.08 181 14.29 312 6 33

Cycle 254 GMT 22/ 7/2020 21:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.36 30 14.36 446 6 6
2 1116.12 13 4.70 1832 6 6
3 1218.44 120 7.35 2121 6 6
4 1225.24 50 8.35 2126 6 6
5 1216.16 36 9.77 2140 6 6
6 96.28 41 14.10 462 6 12
7 0.12 181 14.30 309 6 37

Cycle 253 GMT 13/ 7/2020 3: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 30 14.10 464 6 6
2 1112.88 12 10.14 2017 6 6
3 1913.00 120 6.97 3197 6 6
4 1904.48 50 8.39 3204 6 6
5 1891.40 36 9.88 3140 6 6
6 285.36 41 13.75 799 6 14
7 42.48 41 14.19 370 6 14
8 0.08 181 14.32 311 6 59

Cycle 252 GMT 11/ 7/2020 23:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 30 14.17 464 6 6
2 1117.28 120 11.72 342 6 6
3 1130.32 51 5.27 1950 6 6
4 1138.88 36 9.31 2033 6 6
5 1109.68 40 11.48 2028 6 6
6 895.96 40 12.36 1717 6 9
7 91.92 41 14.12 443 6 13
8 0.12 181 14.31 307 6 39

Cycle 251 GMT 2/ 7/2020 5:23: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.48 30 14.10 482 6 6
2 1126.80 13 4.68 1660 6 6
3 1201.68 120 6.82 2090 6 6
4 1206.16 50 8.01 2097 6 6
5 1195.76 36 9.70 2119 6 6
6 155.88 41 13.87 585 6 14
7 0.12 181 14.26 310 6 35

Cycle 250 GMT 22/ 6/2020 11:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 30 14.23 464 6 6
2 1114.24 13 4.71 1835 6 6
3 1213.48 120 7.56 2113 6 6
4 1217.52 50 8.53 2125 6 6
5 1206.32 36 9.93 2130 6 7
6 132.24 41 14.00 530 6 14
7 0.16 181 14.27 311 6 40

Cycle 249 GMT 12/ 6/2020 17:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.44 30 14.23 464 6 6
2 1114.40 12 10.12 2013 6 6
3 1923.00 120 7.58 3201 6 6
4 1914.48 50 8.93 3202 6 6
5 1901.12 35 9.91 3171 6 6
6 154.08 41 13.97 577 6 14
7 0.12 181 14.34 306 6 35

Cycle 248 GMT 11/ 6/2020 14:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.96 30 14.10 482 6 6
2 1115.92 120 11.28 342 6 6
3 1128.20 51 4.59 1589 6 6
4 1137.76 36 6.89 1963 6 6
5 1293.72 40 10.16 2271 6 6
6 1174.68 40 11.57 2127 6 6
7 724.84 41 12.88 1482 6 10
8 88.28 41 14.08 441 6 13
9 -0.08 181 14.30 304 6 40

Cycle 247 GMT 1/ 6/2020 19: 9: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.44 30 14.23 446 6 6
2 1117.92 120 11.47 341 6 6
3 1130.04 51 4.63 1750 6 6
4 1139.16 36 7.94 2006 6 6
5 1271.60 40 10.75 2248 6 6
6 1099.00 40 11.92 2019 6 6
7 385.64 41 13.52 952 6 13
8 48.44 41 14.16 382 6 14
9 0.04 181 14.29 316 6 54

Cycle 246 GMT 23/ 5/2020 0:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.40 30 14.29 446 6 6
2 1118.64 120 12.10 352 6 6
3 1131.76 51 6.28 1971 6 6
4 1139.52 36 9.77 2026 6 6
5 1022.52 40 11.97 1914 6 6
6 578.28 40 13.18 1240 6 11
7 59.84 40 14.13 402 6 13
8 0.08 181 14.30 313 6 41

Cycle 245 GMT 13/ 5/2020 5:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.56 30 14.23 464 6 6
2 1119.48 12 10.17 2028 6 6
3 1910.84 120 7.89 3189 6 6
4 1900.08 50 9.20 3163 6 6
5 1884.52 36 10.00 3128 6 6
6 148.88 41 13.93 568 6 14
7 0.08 181 14.31 312 6 35

Cycle 244 GMT 12/ 5/2020 3: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 30 14.23 464 6 6
2 1142.84 120 4.60 1771 6 6
3 1158.76 36 8.67 2054 6 6
4 1259.96 40 11.01 2238 6 6
5 1089.48 40 12.12 2005 6 7
6 349.92 41 13.59 901 6 14
7 41.56 41 14.16 373 6 15
8 0.12 181 14.29 311 6 59

Cycle 243 GMT 2/ 5/2020 8: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.24 30 14.17 464 6 6
2 1119.68 120 4.60 1842 6 6
3 1136.60 36 8.88 2036 6 6
4 1257.96 40 11.06 2237 6 6
5 1077.68 40 12.12 1986 6 7
6 318.76 41 13.63 845 6 13
7 35.76 41 14.11 369 6 16
8 0.00 181 14.31 309 6 63

Cycle 242 GMT 22/ 4/2020 13:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 30 14.36 446 6 6
2 1107.08 120 6.48 1933 6 6
3 1113.60 31 9.97 2003 6 6
4 909.64 40 12.30 1731 6 9
5 146.64 41 13.90 566 6 15
6 0.08 181 14.27 311 6 33

Cycle 241 GMT 12/ 4/2020 19:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 30 14.04 464 6 6
2 1119.24 12 10.12 2045 6 6
3 1908.48 120 8.21 3192 6 6
4 1895.08 31 10.15 3152 6 6
5 789.64 40 13.12 1560 6 12
6 85.84 40 14.08 458 6 15
7 0.12 181 14.35 312 6 43

Cycle 240 GMT 11/ 4/2020 16:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.88 30 14.23 446 6 6
2 1111.04 120 4.60 1841 6 6
3 1125.92 31 9.19 2026 6 6
4 1243.84 40 11.33 2225 6 6
5 1075.68 40 12.30 1987 6 7
6 340.64 41 13.64 886 6 14
7 42.56 41 14.14 377 6 16
8 0.08 181 14.30 316 6 60

Cycle 239 GMT 1/ 4/2020 21:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.68 30 14.23 464 6 6
2 1131.36 120 4.80 1896 6 6
3 1145.04 30 9.44 2065 6 6
4 1222.52 41 11.49 2193 6 6
5 1025.64 41 12.42 1915 6 8
6 232.20 41 13.79 711 6 15
7 33.44 41 14.18 363 6 17
8 0.08 181 14.31 311 6 74

Cycle 238 GMT 23/ 3/2020 2:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.12 30 14.29 446 6 6
2 1115.56 120 6.76 1947 6 6
3 1122.28 31 10.14 2023 6 6
4 895.68 40 12.49 1725 6 9
5 136.28 41 13.95 544 6 14
6 0.08 181 14.30 309 6 38

Cycle 237 GMT 13/ 3/2020 8:57: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.84 30 14.23 464 6 6
2 1116.72 12 10.37 2024 6 6
3 1905.48 120 8.60 3166 6 6
4 1892.08 31 10.18 3192 6 6
5 521.80 41 13.46 1153 6 12
6 86.00 41 14.06 461 6 16
7 0.12 181 14.33 322 6 46

Cycle 236 GMT 12/ 3/2020 5:41: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.04 30 14.23 446 6 6
2 1133.48 120 4.61 1879 6 6
3 1149.40 31 9.35 2062 6 6
4 1287.76 40 11.40 2298 6 6
5 1116.20 40 12.33 2056 6 7
6 358.48 41 13.61 929 6 14
7 48.28 41 14.14 389 6 15
8 0.00 181 14.31 317 6 61

Cycle 235 GMT 2/ 3/2020 10:48: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.00 30 14.17 464 6 6
2 1118.48 120 4.78 1884 6 6
3 1132.16 31 9.47 2048 6 6
4 1225.76 40 11.51 2202 6 6
5 1025.16 40 12.38 1924 6 8
6 228.84 41 13.79 710 6 15
7 29.84 41 14.18 357 6 16
8 0.08 181 14.31 316 6 73

Cycle 234 GMT 21/ 2/2020 16:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.52 30 14.23 482 6 6
2 1117.68 120 6.34 1948 6 6
3 1124.76 31 9.95 2027 6 6
4 920.04 40 12.36 1735 6 8
5 139.60 41 13.88 556 6 14
6 26.20 41 14.18 348 6 16
7 0.00 181 14.27 313 6 73

Cycle 233 GMT 11/ 2/2020 22:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.80 30 14.17 464 6 6
2 1124.64 12 9.86 2060 6 6
3 1927.76 120 6.98 3204 6 6
4 1916.00 31 10.07 3212 6 6
5 1157.40 41 12.62 2067 6 8
6 149.60 41 13.95 581 6 14
7 26.64 41 14.25 345 6 16
8 -0.04 181 14.33 321 6 85

Cycle 232 GMT 10/ 2/2020 18:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.88 30 14.23 446 6 6
2 995.72 31 4.68 1590 6 6
3 969.56 40 10.34 1805 6 6
4 760.24 40 12.50 1519 6 9
5 104.08 40 13.98 488 6 13
6 42.00 40 14.11 378 6 16
7 0.00 181 14.25 313 6 113

Cycle 231 GMT 1/ 2/2020 0:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.48 30 14.23 446 6 6
2 1119.88 120 5.16 1913 6 6
3 1133.04 31 9.86 2038 6 6
4 1074.92 40 12.09 1997 6 6
5 852.60 40 12.80 1670 6 9
6 102.36 41 13.97 497 6 15
7 43.08 41 14.21 372 6 18
8 0.00 179 14.33 310 6 199

Cycle 230 GMT 22/ 1/2020 6:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 30 14.23 464 6 6
2 1114.84 120 6.67 1937 6 6
3 1120.64 31 10.20 2022 6 6
4 914.12 40 12.47 1764 6 9
5 111.76 41 14.00 492 6 12
6 47.48 41 14.19 371 6 15
7 0.04 181 14.34 306 6 106

Cycle 229 GMT 12/ 1/2020 12:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.08 30 14.10 464 6 6
2 1217.52 12 9.96 2188 6 6
3 1928.92 120 7.69 3203 6 6
4 1916.80 31 10.12 3221 6 6
5 896.96 41 12.96 1726 6 11
6 123.48 41 14.00 528 6 15
7 2.44 41 14.33 308 6 23
8 0.00 178 14.36 312 7 177

Cycle 228 GMT 11/ 1/2020 9:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.36 30 14.23 446 6 6
2 997.68 30 4.60 1542 6 6
3 995.08 40 10.35 1847 6 6
4 797.64 40 12.58 1592 6 9
5 111.72 41 13.94 503 6 14
6 45.80 41 14.11 382 6 17
7 0.00 181 14.26 311 6 124

Cycle 227 GMT 1/ 1/2020 15:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.24 30 14.36 446 6 6
2 1130.68 80 11.23 345 6 6
3 1140.00 61 4.75 1897 6 6
4 1149.24 31 9.33 2052 6 6
5 1254.28 40 11.76 2238 6 6
6 1079.12 40 12.51 1960 6 7
7 305.96 41 13.69 833 6 14
8 37.80 41 14.17 370 6 16
9 0.12 181 14.32 312 6 66

Cycle 226 GMT 22/12/2019 21: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 30 14.29 446 6 6
2 1132.16 80 11.75 355 6 6
3 1141.92 61 6.44 1995 6 6
4 1149.92 31 10.25 2066 6 6
5 1043.24 40 12.26 1950 6 6
6 804.28 40 12.81 1612 6 11
7 96.52 41 14.05 475 6 15
8 0.16 181 14.32 312 6 47

Cycle 225 GMT 13/12/2019 2:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.12 30 14.17 446 6 6
2 1109.48 12 10.33 2035 6 6
3 1890.88 80 8.02 3168 6 6
4 1886.96 60 8.56 3140 6 6
5 1875.48 30 10.07 3146 6 6
6 488.20 41 13.43 1113 6 14
7 79.92 41 14.08 452 6 16
8 0.20 181 14.34 319 6 55

Cycle 224 GMT 11/12/2019 23:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.52 30 14.23 464 6 6
2 999.20 31 4.60 1551 6 6
3 994.68 40 10.64 1846 6 6
4 777.48 40 12.66 1562 6 10
5 115.88 40 13.97 501 6 13
6 16.00 40 14.21 324 6 15
7 0.16 181 14.30 309 6 157

Cycle 223 GMT 2/12/2019 6:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.28 30 14.23 446 6 6
2 1141.96 80 11.27 345 6 6
3 1150.84 61 4.68 1890 6 6
4 1159.76 31 9.28 2082 6 6
5 1264.88 40 11.75 2263 6 6
6 1076.56 40 12.45 1999 6 7
7 314.64 41 13.69 848 6 14
8 51.20 41 14.16 385 6 15
9 0.04 181 14.35 309 6 63

Cycle 222 GMT 22/11/2019 11:24: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.24 30 14.23 446 6 6
2 1113.44 80 11.89 357 6 6
3 1122.40 61 6.46 1956 6 6
4 1130.12 31 10.29 2035 6 6
5 1026.96 40 12.31 1911 6 6
6 550.36 41 13.22 1202 6 12
7 98.36 41 14.02 474 6 15
8 0.24 181 14.32 309 6 50

Cycle 221 GMT 12/11/2019 17:13: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.92 30 14.17 446 6 6
2 1116.64 12 10.37 2049 6 6
3 1900.36 80 7.72 3167 6 6
4 1896.08 60 8.19 3152 6 6
5 1885.00 31 10.02 3150 6 6
6 510.76 41 13.42 1141 6 12
7 95.20 41 14.08 474 6 15
8 0.08 180 14.36 310 6 50

Cycle 220 GMT 11/11/2019 14: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.56 30 14.10 464 6 6
2 999.76 30 4.60 1441 6 6
3 1005.08 40 10.73 1870 6 6
4 794.20 40 12.64 1580 6 9
5 122.48 41 13.94 514 6 13
6 0.16 181 14.28 306 6 39

Cycle 219 GMT 1/11/2019 20:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 30 14.17 446 6 6
2 997.88 30 4.60 1468 6 6
3 1001.00 40 10.76 1873 6 6
4 800.88 40 12.53 1592 6 9
5 120.16 41 13.85 517 6 14
6 20.00 41 14.20 331 6 16
7 -0.04 181 14.27 312 6 138

Cycle 218 GMT 23/10/2019 2:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 30 14.29 446 6 6
2 993.04 30 5.71 1693 6 6
3 894.80 40 12.20 1731 6 7
4 656.20 40 12.87 1385 6 11
5 71.52 40 14.06 421 6 13
6 0.04 181 14.27 308 6 44

Cycle 217 GMT 13/10/2019 9: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.84 30 14.17 482 6 6
2 1102.84 15 10.66 2032 6 6
3 1831.36 61 8.54 3071 6 6
4 1828.16 80 8.36 3051 6 6
5 1813.52 31 10.14 3051 6 6
6 354.36 41 13.65 905 6 14
7 41.20 41 14.21 373 6 16
8 0.20 180 14.33 318 6 67

Cycle 216 GMT 12/10/2019 6: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.56 30 14.17 482 6 6
2 1005.24 31 4.60 1505 6 6
3 994.92 40 11.12 1874 6 6
4 786.92 40 12.60 1574 6 10
5 106.12 40 13.98 491 6 14
6 15.40 40 14.25 326 6 16
7 0.00 179 14.27 314 6 141

Cycle 215 GMT 2/10/2019 12:30:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.24 30 14.10 482 6 6
2 1005.16 30 4.60 1518 6 6
3 999.48 40 11.11 1872 6 6
4 797.52 40 12.60 1570 6 10
5 112.08 41 13.96 496 6 14
6 2.48 41 14.26 308 6 15
7 0.04 181 14.28 311 6 187

Cycle 214 GMT 22/ 9/2019 18:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.08 30 14.23 482 6 6
2 1002.24 30 5.92 1714 6 6
3 908.68 40 12.20 1755 6 7
4 670.84 40 12.95 1396 6 11
5 66.80 40 14.05 420 6 14
6 0.16 180 14.25 312 6 47

Cycle 213 GMT 13/ 9/2019 1:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.76 30 14.17 446 6 6
2 1117.40 15 10.73 2035 6 6
3 1831.00 61 8.48 3095 6 6
4 1828.08 80 8.23 3088 6 6
5 1813.88 31 10.07 3056 6 6
6 371.96 41 13.57 933 6 14
7 43.08 41 14.20 372 6 15
8 0.00 180 14.32 314 6 67

Cycle 212 GMT 11/ 9/2019 22:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.52 30 14.17 464 6 6
2 1000.00 30 4.60 1535 6 6
3 990.84 40 11.40 1852 6 6
4 784.68 40 12.67 1564 6 10
5 104.12 41 13.96 478 6 13
6 0.12 181 14.26 307 6 43

Cycle 211 GMT 2/ 9/2019 4:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.60 30 14.23 482 6 6
2 1006.08 31 4.72 1595 6 6
3 964.32 40 11.61 1827 6 6
4 742.32 40 12.68 1514 6 9
5 84.40 40 13.99 449 6 14
6 0.04 181 14.25 309 6 44

Cycle 210 GMT 23/ 8/2019 11: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.84 30 14.23 464 6 6
2 1004.12 30 5.89 1708 6 6
3 880.08 40 12.31 1708 6 7
4 650.92 40 12.99 1352 6 11
5 58.08 40 14.07 404 6 14
6 0.04 181 14.27 310 6 44

Cycle 209 GMT 13/ 8/2019 17:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.56 30 14.17 482 6 6
2 1115.88 15 10.72 2041 6 6
3 1819.84 61 8.70 3053 6 6
4 1816.64 80 8.39 3041 6 6
5 1802.00 31 10.11 3037 6 6
6 318.92 41 13.64 853 6 15
7 38.64 41 14.20 369 6 16
8 0.04 181 14.31 310 6 72

Cycle 208 GMT 12/ 8/2019 14:47: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.52 30 14.17 464 6 6
2 996.76 31 4.70 1580 6 6
3 941.64 40 11.70 1784 6 6
4 727.64 40 12.76 1481 6 10
5 77.68 40 14.02 438 6 14
6 0.12 181 14.26 308 6 44

Cycle 207 GMT 2/ 8/2019 21:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 30 14.17 464 6 6
2 1007.00 30 4.68 1593 6 6
3 943.72 40 11.77 1793 6 6
4 736.20 40 12.75 1494 6 10
5 91.36 41 14.02 459 6 14
6 0.12 181 14.28 307 6 43

Cycle 206 GMT 24/ 7/2019 3:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.92 30 14.36 464 6 6
2 1005.08 30 6.10 1721 6 6
3 889.52 40 12.33 1731 6 7
4 659.80 40 12.97 1382 6 12
5 51.64 40 14.11 385 6 14
6 0.00 181 14.27 309 6 50

Cycle 205 GMT 14/ 7/2019 10:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.44 30 14.17 464 6 6
2 1125.08 15 10.84 2053 6 6
3 1818.44 61 8.83 3058 6 6
4 1815.16 80 8.53 3030 6 6
5 1800.36 31 10.11 3052 6 6
6 154.68 41 13.89 586 6 14
7 26.56 41 14.22 348 6 15
8 0.08 180 14.34 311 6 75

Cycle 204 GMT 13/ 7/2019 7:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 30 14.23 464 6 6
2 999.72 30 4.78 1625 6 6
3 927.56 40 11.93 1757 6 6
4 707.00 40 12.91 1412 6 10
5 76.48 40 14.01 434 6 14
6 0.04 181 14.24 308 6 43

Cycle 203 GMT 3/ 7/2019 13:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.84 30 14.04 482 6 6
2 1006.44 30 4.73 1614 6 6
3 953.64 40 11.80 1801 6 6
4 735.56 40 12.76 1497 6 10
5 87.56 40 14.01 451 6 13
6 0.12 181 14.27 312 6 43

Cycle 202 GMT 23/ 6/2019 20: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 30 14.23 464 6 6
2 998.64 30 6.03 1714 6 6
3 890.20 40 12.41 1710 6 7
4 403.48 40 13.43 979 6 12
5 52.76 40 14.10 396 6 14
6 0.08 181 14.27 313 6 55

Cycle 201 GMT 14/ 6/2019 2:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.44 30 14.17 464 6 6
2 1103.20 15 10.84 2026 6 6
3 1812.52 61 8.98 3051 6 6
4 1809.28 80 8.75 3018 6 6
5 1794.12 31 10.16 3020 6 6
6 128.44 41 13.98 529 6 13
7 23.00 41 14.25 343 6 16
8 0.04 181 14.33 308 6 82

Cycle 200 GMT 12/ 6/2019 23:51: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 30 14.10 464 6 6
2 996.12 30 4.92 1621 6 6
3 935.40 40 11.87 1786 6 6
4 505.80 40 13.24 1145 6 11
5 91.96 41 14.00 465 6 15
6 0.08 181 14.26 306 6 48

Cycle 199 GMT 3/ 6/2019 6:11: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.76 30 14.10 464 6 6
2 1003.20 30 4.92 1628 6 6
3 941.56 40 11.83 1807 6 6
4 708.52 40 12.86 1429 6 10
5 73.24 40 14.03 434 6 14
6 0.04 181 14.29 306 6 46

Cycle 198 GMT 24/ 5/2019 12:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.24 30 14.29 464 6 6
2 1009.96 30 6.23 1750 6 6
3 873.68 40 12.46 1700 6 7
4 406.24 40 13.38 996 6 13
5 58.00 40 14.12 394 6 14
6 0.12 181 14.28 308 6 54

Cycle 197 GMT 14/ 5/2019 19: 7: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.24 30 14.29 464 6 6
2 1106.72 15 10.98 2026 6 6
3 1808.84 61 9.08 3033 6 6
4 1805.56 80 8.67 3043 6 6
5 1790.52 31 10.20 3021 6 7
6 145.80 41 13.93 572 6 14
7 22.68 41 14.27 336 6 15
8 0.08 181 14.37 305 6 87

Cycle 196 GMT 13/ 5/2019 16:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.72 30 13.97 482 6 6
2 1000.64 30 5.02 1645 6 6
3 938.24 40 11.94 1787 6 6
4 708.28 40 12.88 1459 6 10
5 73.04 40 14.04 431 6 13
6 0.04 181 14.27 315 6 44

Cycle 195 GMT 3/ 5/2019 22:47: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 30 14.04 482 6 6
2 1006.76 31 5.13 1660 6 6
3 936.68 40 12.01 1784 6 6
4 486.76 40 13.27 1120 6 12
5 84.12 40 14.05 446 6 14
6 0.12 181 14.28 311 6 51

Cycle 194 GMT 24/ 4/2019 5: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.88 30 14.29 464 6 6
2 999.00 30 6.24 1760 6 6
3 888.48 40 12.45 1727 6 7
4 419.08 40 13.39 1019 6 13
5 61.80 41 14.10 412 6 14
6 0.08 181 14.29 312 6 52

Cycle 193 GMT 14/ 4/2019 11:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.64 30 14.23 464 6 6
2 1114.84 15 10.90 2035 6 6
3 1809.64 61 9.19 3039 6 6
4 1806.00 80 8.88 3024 6 6
5 1790.28 31 10.22 3003 6 7
6 131.52 41 13.91 541 6 14
7 21.68 41 14.28 336 6 15
8 0.04 180 14.34 313 6 100

Cycle 192 GMT 13/ 4/2019 8:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.44 29 14.17 482 6 6
2 1027.36 1 11.05 1946 6 6
3 1019.12 30 5.35 1706 6 6
4 932.20 40 12.17 1756 6 6
5 692.32 40 12.98 1387 6 10
6 81.04 40 14.09 437 6 13
7 0.08 181 14.31 306 6 42

Cycle 191 GMT 3/ 4/2019 15:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.24 30 14.23 464 6 6
2 1002.64 31 5.16 1686 6 6
3 921.36 40 11.97 1762 6 6
4 690.20 40 12.93 1425 6 11
5 70.44 40 14.10 421 6 14
6 0.12 181 14.27 311 6 45

Cycle 190 GMT 24/ 3/2019 21:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.44 30 14.36 464 6 6
2 1001.00 31 6.46 1758 6 6
3 870.84 40 12.45 1693 6 7
4 394.88 40 13.41 980 6 13
5 56.08 40 14.17 388 6 13
6 0.08 181 14.31 307 6 55

Cycle 189 GMT 15/ 3/2019 4:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 29 14.23 464 6 6
2 1029.48 1 11.05 1946 6 6
3 1022.08 1 10.22 1910 6 6
4 1131.56 15 11.10 2071 6 6
5 1804.12 61 9.35 3027 6 6
6 1800.68 80 8.96 3007 6 6
7 1784.88 30 10.18 3017 6 7
8 119.04 41 14.02 505 6 13
9 19.08 41 14.27 332 6 15
10 0.04 181 14.37 309 6 113

Cycle 188 GMT 14/ 3/2019 1:30: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.04 32 14.23 464 6 6
2 921.12 -1 14.23 464 6 6
3 954.28 -1 14.23 464 6 6
4 1012.16 30 5.34 1722 6 6
5 935.24 40 11.99 1791 6 6
6 698.04 40 12.88 1448 6 11
7 68.96 40 14.09 421 6 13
8 0.08 181 14.30 307 6 50

Cycle 187 GMT 4/ 3/2019 7:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.56 30 14.10 464 6 6
2 993.68 31 5.46 1707 6 6
3 915.04 40 11.96 1748 6 6
4 465.08 40 13.29 1087 6 12
5 87.16 40 14.03 453 6 15
6 0.12 181 14.30 310 6 48

Cycle 186 GMT 22/ 2/2019 14:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.72 30 14.29 464 6 6
2 1005.32 30 6.69 1791 6 6
3 888.56 40 12.37 1704 6 7
4 405.16 40 13.39 1000 6 12
5 62.84 40 14.11 414 6 14
6 0.08 180 14.31 309 6 52

Cycle 185 GMT 12/ 2/2019 20:49: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.00 31 14.23 464 6 6
2 931.16 -1 14.23 464 6 6
3 972.24 -1 14.23 464 6 6
4 1123.92 15 11.12 2068 6 6
5 1812.96 61 9.40 3060 6 6
6 1809.72 80 9.17 3027 6 6
7 1794.64 31 10.31 3012 6 7
8 112.20 41 14.03 502 6 14
9 48.48 41 14.24 384 6 16
10 0.00 181 14.35 313 8 117

Cycle 184 GMT 11/ 2/2019 18: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.84 24 14.23 482 6 6
2 1023.96 4 12.25 1875 6 6
3 1108.96 3 12.12 2053 6 6
4 1056.12 1 11.37 2000 6 6
5 1037.12 30 5.41 1771 6 6
6 932.52 40 12.15 1770 6 6
7 705.64 40 12.91 1452 6 11
8 70.76 40 14.14 414 6 14
9 0.04 181 14.34 302 6 46

Cycle 183 GMT 2/ 2/2019 2:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.72 30 14.29 446 6 6
2 1010.48 30 5.92 1782 6 6
3 912.40 40 11.89 1766 6 7
4 459.80 40 13.29 1077 6 12
5 78.64 41 14.09 440 6 15
6 0.04 181 14.31 311 6 52

Cycle 182 GMT 23/ 1/2019 9:18: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.80 30 14.36 446 6 6
2 994.12 30 7.41 1802 6 6
3 858.40 40 12.36 1668 6 7
4 168.64 40 13.85 601 6 13
5 74.48 41 14.12 429 6 15
6 0.12 181 14.32 312 6 61

Cycle 181 GMT 13/ 1/2019 15:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 25 14.36 464 6 6
2 1051.00 4 12.38 1982 6 6
3 1071.36 2 11.75 1982 6 6
4 1031.24 1 10.66 1946 6 6
5 1128.24 15 11.49 2056 6 6
6 1787.20 61 10.31 3001 6 6
7 1783.24 80 10.06 2977 6 6
8 1766.36 31 10.51 2949 6 8
9 78.68 41 14.20 430 6 13
10 0.04 180 14.42 309 6 43

Cycle 180 GMT 12/ 1/2019 13: 3: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.80 30 14.42 446 6 6
2 1130.08 10 4.75 1960 6 6
3 2004.08 46 4.83 2590 6 6
4 2006.52 69 5.00 2860 6 6
5 2010.44 31 8.73 3353 6 6
6 1891.28 40 11.67 3173 6 6
7 1665.48 40 12.30 2825 6 6
8 615.48 41 13.43 1275 6 12
9 77.64 41 14.23 431 6 14
10 0.12 181 14.46 306 6 49

Cycle 179 GMT 2/ 1/2019 13:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.00 30 14.42 464 6 6
2 1121.68 10 4.75 1946 6 6
3 2004.12 46 4.83 2613 6 6
4 2005.76 69 5.05 2883 6 6
5 2008.24 31 8.87 3336 6 6
6 1888.20 40 11.76 3133 6 6
7 1666.52 40 12.30 2824 6 6
8 617.40 41 13.42 1260 6 11
9 82.36 41 14.25 425 6 14
10 0.20 180 14.50 302 6 49

Cycle 178 GMT 23/12/2018 14:14: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.36 30 14.48 428 6 6
2 1121.96 10 4.74 1913 6 6
3 2000.16 46 4.83 2566 6 6
4 2002.56 69 5.03 2815 6 6
5 2006.32 31 8.79 3347 6 6
6 1902.32 40 11.73 3199 6 6
7 1675.00 40 12.31 2852 6 6
8 867.92 41 13.18 1639 6 11
9 108.84 41 14.17 480 6 15
10 0.12 181 14.48 306 6 45

Cycle 177 GMT 13/12/2018 15: 6: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.68 30 14.36 482 6 6
2 1111.08 8 4.73 1825 6 6
3 2005.36 33 4.81 2392 6 6
4 2006.88 56 5.00 2665 6 6
5 2009.76 26 8.35 3378 6 6
6 1924.28 41 11.48 3231 6 6
7 1709.80 41 12.20 2920 6 6
8 911.12 41 13.11 1712 6 11
9 126.60 40 14.05 533 6 15
10 0.12 181 14.43 308 6 42

Cycle 176 GMT 3/12/2018 15:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.96 30 14.29 482 6 6
2 1117.00 8 4.73 1821 6 6
3 2002.16 33 4.81 2400 6 6
4 2003.64 56 5.02 2697 6 6
5 2006.40 26 8.44 3364 6 6
6 1907.12 40 11.67 3167 6 6
7 1698.36 40 12.28 2860 6 7
8 919.52 41 13.10 1725 6 10
9 76.16 41 14.25 426 6 14
10 0.08 181 14.46 306 6 41

Cycle 175 GMT 23/11/2018 16:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.60 30 14.36 446 6 6
2 1121.12 8 4.74 1821 6 6
3 2003.44 33 4.82 2477 6 6
4 2005.28 56 5.11 2801 6 6
5 2008.68 26 9.02 3328 6 6
6 1916.72 40 11.69 3211 6 6
7 1696.76 40 12.27 2892 6 6
8 646.92 41 13.43 1315 6 11
9 79.68 41 14.25 425 6 14
10 0.16 181 14.49 303 6 43

Cycle 174 GMT 13/11/2018 16:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.88 30 14.29 446 6 6
2 1100.28 8 4.73 1807 6 6
3 2003.12 33 4.81 2470 6 6
4 2004.96 56 5.17 2803 6 6
5 2008.44 26 9.01 3356 6 6
6 1906.00 40 11.75 3190 6 6
7 1689.40 40 12.30 2855 6 6
8 650.04 41 13.40 1333 6 11
9 71.16 41 14.27 415 6 14
10 0.12 181 14.45 304 6 49

Cycle 173 GMT 3/11/2018 17: 9: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.68 30 14.48 446 6 6
2 1109.48 8 4.73 1830 6 6
3 2003.32 33 4.86 2562 6 6
4 2005.44 56 5.23 2955 6 6
5 2009.20 26 9.32 3341 6 6
6 1917.32 40 11.80 3224 6 6
7 1700.84 40 12.30 2897 6 7
8 670.48 41 13.35 1367 6 12
9 86.96 41 14.27 434 6 13
10 0.04 181 14.49 301 6 44

Cycle 172 GMT 24/10/2018 17:34: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.84 30 14.42 464 6 6
2 1118.76 8 4.73 1816 6 6
3 2001.32 33 4.86 2627 6 6
4 2003.12 56 5.35 3040 6 6
5 2006.04 26 9.53 3374 6 6
6 1898.52 40 11.91 3159 6 6
7 1468.64 41 12.60 2500 6 7
8 686.48 41 13.37 1375 6 12
9 74.20 41 14.31 420 6 14
10 0.04 181 14.49 302 6 52

Cycle 171 GMT 14/10/2018 18: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.76 30 14.42 464 6 6
2 1115.64 8 4.73 1785 6 6
3 2004.64 33 4.86 2641 6 6
4 2006.00 56 5.43 3138 6 6
5 2008.16 26 9.83 3345 6 6
6 1865.08 40 12.04 3102 6 6
7 1632.32 40 12.46 2743 6 6
8 580.92 41 13.52 1199 6 11
9 62.44 41 14.32 397 6 14
10 0.16 181 14.46 309 6 50

Cycle 170 GMT 4/10/2018 18:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.36 30 14.42 464 6 6
2 1123.08 8 4.69 1664 6 6
3 2002.60 33 4.81 2469 6 6
4 2004.00 56 5.32 3089 6 6
5 2006.48 26 9.81 3357 6 6
6 1870.56 40 12.03 3142 6 6
7 1631.36 40 12.48 2726 6 7
8 569.08 41 13.50 1211 6 13
9 62.60 41 14.30 402 6 14
10 0.00 181 14.46 312 6 52

Cycle 169 GMT 24/ 9/2018 19:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.36 30 14.29 482 6 6
2 1119.88 3 4.66 1571 6 6
3 2004.04 33 4.78 2283 6 6
4 2006.36 34 6.23 3220 6 6
5 2029.36 40 11.67 3367 6 6
6 1816.24 40 12.18 3048 6 6
7 833.32 41 13.21 1586 6 10
8 133.12 41 14.14 528 6 14
9 0.08 181 14.46 304 6 36

Cycle 168 GMT 14/ 9/2018 19:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.36 30 14.42 464 6 6
2 1125.76 3 4.66 1553 6 6
3 2001.96 33 4.79 2279 6 6
4 2003.96 34 6.29 3246 6 6
5 2019.88 40 11.78 3378 6 6
6 1815.36 40 12.21 3058 6 6
7 856.92 41 13.20 1627 6 10
8 133.16 41 14.17 522 6 14
9 0.08 181 14.46 305 6 38

Cycle 167 GMT 4/ 9/2018 19:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.52 30 14.42 464 6 6
2 1137.88 3 4.66 1526 6 6
3 2008.36 33 4.78 2282 6 6
4 2010.52 34 6.42 3291 6 6
5 2008.68 40 11.84 3341 6 6
6 1815.80 40 12.25 3039 6 7
7 846.92 41 13.25 1592 6 10
8 130.16 41 14.16 527 6 14
9 0.16 181 14.45 309 6 40

Cycle 166 GMT 25/ 8/2018 19:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.64 30 14.48 464 6 6
2 1111.48 3 4.66 1526 6 6
3 2004.16 33 4.82 2428 6 6
4 2006.00 34 6.93 3390 6 6
5 1952.16 40 11.92 3251 6 6
6 1754.20 40 12.26 2964 6 6
7 769.56 41 13.34 1472 6 11
8 109.08 41 14.25 486 6 14
9 0.16 181 14.46 309 6 41

Cycle 165 GMT 15/ 8/2018 19:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.56 30 14.42 464 6 6
2 1117.52 3 4.66 1499 6 6
3 2002.88 33 4.83 2437 6 6
4 2004.52 34 7.02 3448 6 6
5 1952.04 40 11.95 3258 6 6
6 1752.60 40 12.30 2965 6 7
7 572.48 41 13.53 1213 6 11
8 69.60 41 14.31 412 6 13
9 0.08 181 14.47 311 6 39

Cycle 164 GMT 5/ 8/2018 19:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.64 30 14.48 464 6 6
2 1129.48 3 4.66 1535 6 6
3 2001.36 33 4.86 2628 6 6
4 2003.00 34 8.01 3360 6 6
5 1908.60 40 11.96 3189 6 6
6 1702.84 40 12.30 2871 6 6
7 692.68 41 13.37 1391 6 11
8 77.84 41 14.31 432 6 13
9 0.12 181 14.45 317 6 43

Cycle 163 GMT 26/ 7/2018 20: 4: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 30 14.42 464 6 6
2 1118.64 3 4.66 1535 6 6
3 2003.80 33 4.90 2823 6 6
4 2005.84 34 8.76 3341 6 6
5 1891.20 40 11.88 3157 6 6
6 1465.64 41 12.56 2521 6 7
7 461.04 41 13.61 1059 6 12
8 75.76 41 14.29 430 6 15
9 0.08 181 14.42 319 6 56

Cycle 162 GMT 16/ 7/2018 20:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.36 30 14.36 464 6 6
2 1207.00 3 4.66 1544 6 6
3 1769.12 33 5.69 2771 6 6
4 1769.12 34 9.62 2998 6 6
5 1655.36 40 12.10 2827 6 6
6 1440.64 40 12.49 2473 6 7
7 185.32 41 14.01 626 6 13
8 37.64 41 14.42 364 6 14
9 0.08 181 14.45 315 6 62

Cycle 161 GMT 6/ 7/2018 20: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.72 29 14.36 482 6 6
2 1144.60 3 4.66 1490 6 6
3 1764.76 33 5.40 2632 6 6
4 1764.72 34 9.71 2985 6 6
5 1664.96 40 12.06 2828 6 6
6 1055.60 40 12.94 1899 6 8
7 167.32 41 14.04 594 6 13
8 32.68 41 14.39 354 6 14
9 0.04 181 14.44 316 6 68

Cycle 160 GMT 26/ 6/2018 19:11: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.88 29 14.36 464 6 6
2 1122.64 3 4.69 1642 6 6
3 1226.32 33 8.40 2169 6 6
4 1226.28 34 10.51 2180 6 6
5 1104.44 40 12.67 1996 6 7
6 671.88 41 13.32 1347 6 11
7 63.88 41 14.29 417 6 14
8 0.12 181 14.42 317 6 42

Cycle 159 GMT 16/ 6/2018 19:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.44 29 14.29 482 6 6
2 1136.44 3 4.69 1580 6 6
3 1872.24 33 5.74 2848 6 6
4 1872.20 34 9.54 3144 6 6
5 1736.60 40 11.95 2937 6 6
6 1293.80 41 12.66 2255 6 8
7 169.36 41 14.03 602 6 12
8 36.24 41 14.39 361 6 13
9 0.08 181 14.46 312 6 64

Cycle 158 GMT 6/ 6/2018 19:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.32 29 14.48 446 6 6
2 1130.00 3 4.69 1687 6 6
3 1358.00 33 8.27 2341 6 6
4 1358.00 34 10.22 2388 6 6
5 1235.52 40 12.51 2207 6 6
6 780.48 41 13.19 1501 6 10
7 107.04 41 14.19 486 6 13
8 0.16 181 14.40 321 6 42

Cycle 157 GMT 27/ 5/2018 19:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.44 29 14.42 482 6 6
2 1134.60 3 4.76 1848 6 6
3 1619.64 33 8.23 2702 6 6
4 1619.64 34 9.97 2773 6 6
5 1469.96 40 12.28 2558 6 6
6 768.36 41 13.26 1480 6 9
7 116.44 41 14.20 502 6 13
8 0.20 181 14.43 316 6 38

Cycle 156 GMT 17/ 5/2018 19:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.92 30 14.36 464 6 6
2 969.00 -1 14.36 464 6 6
3 1132.80 3 4.76 1767 6 6
4 2004.92 33 7.49 3191 6 6
5 2005.88 35 9.50 3347 6 6
6 1833.52 41 11.87 3094 6 6
7 1398.84 41 12.56 2393 6 8
8 191.20 41 14.07 629 6 12
9 15.24 41 14.43 324 6 13
10 0.08 181 14.46 313 6 69

Cycle 155 GMT 7/ 5/2018 20:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.12 27 14.42 446 6 6
2 1085.24 2 11.94 2035 6 6
3 1049.20 1 11.94 2017 6 6
4 1145.32 3 4.69 1642 6 6
5 2001.36 33 6.74 3123 6 6
6 2001.52 34 9.66 3336 6 6
7 1849.24 40 11.89 3091 6 6
8 1166.52 41 12.82 2059 6 8
9 180.20 41 14.09 611 6 12
10 14.04 41 14.47 322 6 14
11 0.08 181 14.44 316 6 67

Cycle 154 GMT 27/ 4/2018 20: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 29 14.36 464 6 6
2 943.76 -1 14.36 464 6 6
3 960.88 -1 14.36 464 6 6
4 1195.92 3 4.69 1544 6 6
5 1346.44 33 8.29 2308 6 6
6 1347.48 34 10.32 2358 6 6
7 1261.40 40 12.49 2241 6 6
8 572.64 41 13.43 1207 6 11
9 73.12 41 14.24 425 6 13
10 0.12 181 14.44 310 6 44

Cycle 153 GMT 17/ 4/2018 20:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.92 29 14.48 464 6 6
2 1118.08 4 4.76 1856 6 6
3 1125.40 33 10.07 2040 6 6
4 1125.40 34 10.88 2039 6 6
5 968.16 40 12.84 1843 6 8
6 241.20 41 13.87 721 6 13
7 40.12 41 14.34 368 6 14
8 0.08 181 14.42 314 6 60

Cycle 152 GMT 7/ 4/2018 21:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.72 29 14.42 482 6 6
2 1118.20 3 4.79 1946 6 6
3 2012.84 33 7.89 3307 6 6
4 2014.56 35 9.63 3349 6 6
5 1829.92 41 11.92 3077 6 6
6 1108.68 41 12.83 2010 6 8
7 156.80 41 14.10 572 6 13
8 10.92 41 14.47 316 6 14
9 0.04 181 14.45 313 6 84

Cycle 151 GMT 28/ 3/2018 22:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 29 14.29 482 6 6
2 1117.68 3 4.79 1937 6 6
3 2000.56 33 7.88 3277 6 6
4 2001.36 34 9.65 3328 6 6
5 1805.40 40 11.98 3030 6 6
6 1066.84 41 12.88 1952 6 9
7 144.20 41 14.16 550 6 12
8 0.16 181 14.46 309 6 36

Cycle 150 GMT 18/ 3/2018 22:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 117.00 29 14.42 464 6 6
2 1130.60 3 5.59 1821 6 6
3 2001.04 33 8.07 3290 6 6
4 2001.72 34 9.70 3350 6 6
5 1794.76 40 11.98 3029 6 6
6 1102.72 41 12.86 1999 6 9
7 152.20 41 14.15 563 6 13
8 0.12 180 14.45 310 6 34

Cycle 149 GMT 8/ 3/2018 23:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 29 14.42 464 6 6
2 1130.04 3 5.49 1874 6 6
3 2003.64 33 8.16 3290 6 6
4 2005.04 35 9.71 3348 6 6
5 1816.60 41 11.95 3039 6 6
6 880.44 41 13.10 1675 6 10
7 162.64 41 14.12 586 6 14
8 0.08 181 14.45 308 6 39

Cycle 148 GMT 26/ 2/2018 23:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.20 29 14.29 482 6 6
2 1122.52 3 5.78 1812 6 6
3 2002.64 33 8.21 3278 6 6
4 2004.12 34 9.72 3343 6 6
5 1821.00 40 11.97 3029 6 6
6 896.04 41 13.07 1699 6 10
7 156.92 41 14.11 576 6 14
8 0.12 181 14.44 315 6 33

Cycle 147 GMT 17/ 2/2018 0: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 29 14.42 464 6 6
2 1143.92 3 5.78 1856 6 6
3 2002.00 33 8.46 3337 6 6
4 2002.72 35 9.80 3314 6 6
5 1800.24 41 11.93 3073 6 6
6 841.00 41 13.16 1593 6 10
7 134.32 41 14.15 531 6 14
8 0.12 180 14.45 311 6 40

Cycle 146 GMT 7/ 2/2018 0:40: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.80 29 14.29 482 6 6
2 1126.84 3 6.07 1830 6 6
3 2001.56 33 8.51 3304 6 6
4 2002.24 34 9.81 3359 6 6
5 1805.16 40 11.99 3037 6 6
6 673.96 41 13.35 1357 6 11
7 109.64 41 14.22 484 6 12
8 0.16 181 14.46 313 6 43

Cycle 145 GMT 28/ 1/2018 0:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 29 14.48 464 6 6
2 1118.36 3 5.97 1865 6 6
3 2005.92 33 8.67 3296 6 6
4 2006.60 34 9.84 3337 6 6
5 1795.12 40 11.96 3028 6 6
6 1045.00 41 12.92 1913 6 10
7 124.28 41 14.22 514 6 12
8 5.28 41 14.50 309 6 9
9 0.04 180 14.46 316 6 119

Cycle 144 GMT 18/ 1/2018 1:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.16 29 14.48 464 6 6
2 1130.52 3 6.00 1901 6 6
3 2006.20 33 8.74 3304 6 6
4 2007.16 34 9.91 3374 6 6
5 1819.44 40 11.92 3064 6 6
6 848.52 41 13.08 1674 6 10
7 153.52 41 14.13 566 6 13
8 0.16 181 14.45 311 6 37

Cycle 143 GMT 8/ 1/2018 2:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.92 29 14.42 464 6 6
2 1112.12 3 6.35 1892 6 6
3 2001.96 33 9.02 3281 6 6
4 2002.80 34 10.06 3327 6 6
5 1802.04 40 11.98 3028 6 6
6 855.72 41 13.12 1635 6 10
7 142.28 41 14.14 550 6 13
8 0.16 181 14.45 313 6 37

Cycle 142 GMT 29/12/2017 2:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.44 29 14.36 482 6 6
2 1119.48 3 6.10 1839 6 6
3 2002.00 33 8.88 3307 6 6
4 2002.76 35 10.04 3339 6 6
5 1798.08 41 11.91 3048 6 6
6 831.64 41 13.16 1577 6 10
7 136.08 41 14.18 533 6 14
8 0.12 181 14.44 314 6 42

Cycle 141 GMT 19/12/2017 3:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.48 29 14.42 464 6 6
2 1140.88 3 5.84 1892 6 6
3 1491.36 33 9.89 2573 6 6
4 1491.36 34 10.69 2598 6 6
5 1312.84 40 12.45 2314 6 7
6 374.04 41 13.72 911 6 12
7 52.92 41 14.33 393 6 13
8 0.08 181 14.40 318 6 52

Cycle 140 GMT 9/12/2017 3:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.96 29 14.48 482 6 6
2 1142.36 3 6.77 1972 6 6
3 1318.00 33 10.51 2340 6 6
4 1318.00 34 11.08 2339 6 6
5 1133.68 40 12.68 2054 6 7
6 198.84 41 13.97 660 6 13
7 17.80 41 14.44 325 6 13
8 0.00 181 14.40 312 6 64

Cycle 139 GMT 29/11/2017 4:15:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.80 29 14.42 464 6 6
2 1128.24 3 6.93 2035 6 6
3 1924.08 33 9.73 3172 6 6
4 1923.60 34 10.31 3215 6 6
5 1710.12 40 12.07 2882 6 6
6 730.84 41 13.26 1448 6 11
7 103.16 41 14.23 474 6 13
8 0.12 181 14.43 312 6 42

Cycle 138 GMT 19/11/2017 3:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.16 29 14.42 464 6 6
2 1124.76 3 6.96 2062 6 6
3 2004.76 33 9.78 3325 6 6
4 2004.88 34 10.30 3352 6 6
5 1783.24 40 12.01 2991 6 6
6 599.44 41 13.42 1296 6 12
7 83.52 41 14.31 433 6 12
8 0.16 180 14.43 311 6 43

Cycle 137 GMT 9/11/2017 3:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 29 14.42 464 6 6
2 1138.36 3 7.22 2089 6 6
3 2007.16 33 9.91 3297 6 6
4 2007.40 34 10.33 3334 6 6
5 1790.36 40 11.99 3023 6 6
6 779.20 41 13.21 1526 6 10
7 120.92 41 14.22 511 6 14
8 0.08 181 14.42 315 6 41

Cycle 136 GMT 30/10/2017 4:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 29 14.29 482 6 6
2 1135.40 3 7.34 2106 6 6
3 2007.84 33 9.96 3360 6 6
4 2008.28 35 10.37 3348 6 6
5 1795.84 41 12.00 3047 6 6
6 580.96 41 13.44 1248 6 11
7 83.04 41 14.28 442 6 13
8 0.12 181 14.44 312 6 42

Cycle 135 GMT 20/10/2017 4:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 29 14.42 464 6 6
2 1152.56 3 7.31 2124 6 6
3 2007.04 33 9.99 3351 6 6
4 2007.20 35 10.39 3343 6 6
5 1790.20 41 11.97 3042 6 6
6 564.44 41 13.47 1215 6 11
7 123.08 41 14.18 509 6 14
8 0.16 181 14.42 313 6 43

Cycle 134 GMT 10/10/2017 5: 1: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.40 29 14.42 482 6 6
2 1112.04 3 7.28 2053 6 6
3 1932.04 33 10.04 3215 6 6
4 1931.36 34 10.46 3265 6 6
5 1714.24 40 12.07 2930 6 6
6 731.24 41 13.27 1472 6 11
7 91.96 41 14.23 467 6 14
8 0.00 181 14.41 314 6 44

Cycle 133 GMT 30/ 9/2017 4:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.44 29 14.36 482 6 6
2 972.44 -1 14.36 482 6 6
3 1043.32 1 11.94 2000 6 6
4 1120.56 3 7.41 2080 6 6
5 2004.72 33 10.13 3333 6 6
6 2004.84 34 10.37 3371 6 6
7 1580.24 40 12.26 2719 6 6
8 817.68 41 13.19 1560 6 11
9 112.24 41 14.19 501 6 15
10 0.08 181 14.40 318 6 44

Cycle 132 GMT 20/ 9/2017 4:59: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.80 29 14.42 482 6 6
2 1180.64 3 7.66 2222 6 6
3 1692.40 33 10.41 2885 6 6
4 1691.68 34 10.84 2880 6 6
5 1284.44 40 12.57 2266 6 7
6 391.08 41 13.69 963 6 13
7 60.16 41 14.29 410 6 14
8 0.04 181 14.38 320 6 49

Cycle 131 GMT 10/ 9/2017 4:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.84 29 14.42 482 6 6
2 1134.28 3 7.79 2187 6 6
3 2005.76 33 10.15 3333 6 6
4 2006.24 35 10.46 3356 6 6
5 1792.68 41 12.03 3041 6 6
6 536.20 41 13.50 1176 6 11
7 58.60 41 14.33 404 6 14
8 0.04 181 14.39 320 6 43

Cycle 130 GMT 31/ 8/2017 5: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 29 14.23 500 6 6
2 1132.24 3 7.76 2187 6 6
3 2004.80 33 10.24 3325 6 6
4 2004.80 34 10.45 3361 6 6
5 1568.76 40 12.26 2695 6 6
6 628.28 41 13.40 1258 6 10
7 78.24 41 14.28 438 6 14
8 0.04 181 14.41 316 6 44

Cycle 129 GMT 21/ 8/2017 5: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.92 29 14.42 464 6 6
2 1122.44 3 8.59 2062 6 6
3 1882.92 33 10.30 3156 6 6
4 1882.96 34 10.59 3181 6 6
5 1455.12 40 12.41 2515 6 7
6 495.68 41 13.56 1095 6 12
7 53.40 41 14.32 402 6 13
8 0.04 181 14.38 321 6 46

Cycle 128 GMT 11/ 8/2017 4:39: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.32 29 14.42 464 6 6
2 1124.68 3 8.65 2151 6 6
3 2004.96 33 10.22 3353 6 6
4 2004.72 34 10.45 3365 6 6
5 1577.36 40 12.23 2694 6 6
6 593.24 41 13.45 1238 6 11
7 52.52 41 14.30 404 6 13
8 0.08 181 14.37 327 6 54

Cycle 127 GMT 1/ 8/2017 4:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 29 14.48 464 6 6
2 1116.56 3 9.22 2044 6 6
3 2002.72 33 10.26 3351 6 6
4 2002.64 34 10.47 3359 6 6
5 1569.92 40 12.26 2673 6 6
6 601.64 41 13.44 1261 6 11
7 61.12 41 14.32 414 6 13
8 0.04 181 14.38 326 6 51

Cycle 126 GMT 22/ 7/2017 4:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.04 29 14.42 464 6 6
2 1127.32 3 9.23 2089 6 6
3 2002.36 33 10.29 3338 6 6
4 2002.36 34 10.42 3356 6 6
5 1563.36 40 12.27 2652 6 6
6 577.32 41 13.42 1222 6 11
7 59.52 41 14.33 406 6 13
8 0.00 181 14.38 320 6 46

Cycle 125 GMT 12/ 7/2017 4:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.08 28 14.29 482 6 6
2 1142.76 3 8.36 2214 6 6
3 2002.24 33 10.32 3356 6 6
4 2002.24 35 10.41 3346 6 6
5 1566.40 41 12.25 2666 6 6
6 577.48 41 13.43 1223 6 11
7 52.72 41 14.34 397 6 13
8 0.16 181 14.40 315 6 65

Cycle 124 GMT 2/ 7/2017 5:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.96 30 14.23 500 6 6
2 959.56 -1 14.23 500 6 6
3 1122.12 3 9.42 2080 6 6
4 1541.68 33 10.96 2680 6 6
5 1541.56 35 10.98 2676 6 6
6 1321.76 41 12.49 2294 6 7
7 308.00 41 13.82 832 6 13
8 42.40 41 14.32 383 6 14
9 0.12 181 14.38 322 6 59

Cycle 123 GMT 22/ 6/2017 5:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.92 29 14.29 482 6 6
2 1019.96 1 9.20 1946 6 6
3 1132.24 3 8.91 2142 6 6
4 2002.68 33 10.37 3352 6 6
5 2002.52 34 10.34 3373 6 6
6 1567.20 40 12.25 2672 6 7
7 593.44 41 13.45 1236 6 10
8 64.92 41 14.30 414 6 13
9 0.12 181 14.39 319 6 43

Cycle 122 GMT 12/ 6/2017 6: 1: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 29 14.36 482 6 6
2 1131.04 3 9.58 2080 6 6
3 1572.12 33 10.90 2733 6 6
4 1572.12 35 10.88 2735 6 6
5 1352.36 41 12.44 2346 6 7
6 342.08 41 13.76 881 6 13
7 49.72 41 14.35 398 6 14
8 0.12 181 14.37 327 6 53

Cycle 121 GMT 2/ 6/2017 6:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.04 28 14.48 464 6 6
2 1143.64 3 9.80 2089 6 6
3 2002.04 33 10.40 3381 6 6
4 2001.04 34 10.41 3355 6 6
5 1555.96 40 12.29 2651 6 6
6 592.16 41 13.42 1254 6 11
7 58.20 41 14.35 398 6 13
8 0.20 181 14.40 323 6 42

Cycle 120 GMT 23/ 5/2017 5:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.16 29 14.48 464 6 6
2 972.28 -1 14.48 464 6 6
3 1153.56 3 9.39 2142 6 6
4 2005.36 33 10.41 3393 6 6
5 2005.00 34 10.36 3373 6 6
6 1571.96 40 12.24 2687 6 6
7 585.20 41 13.45 1228 6 11
8 57.48 41 14.33 408 6 13
9 0.28 181 14.38 324 6 46

Cycle 119 GMT 13/ 5/2017 6:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.44 29 14.42 482 6 6
2 1121.24 3 9.55 2053 6 6
3 1884.64 33 10.41 3183 6 6
4 1884.12 32 10.53 3168 6 6
5 1684.52 41 11.99 2855 6 6
6 673.68 41 13.32 1350 6 10
7 65.52 41 14.31 419 6 13
8 0.16 180 14.39 324 6 42

Cycle 118 GMT 3/ 5/2017 6: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.96 29 14.36 464 6 6
2 1132.60 3 9.03 2116 6 6
3 1579.24 33 10.79 2748 6 6
4 1579.20 33 10.89 2725 6 6
5 1401.16 40 12.35 2442 6 7
6 416.24 41 13.64 1005 6 13
7 55.48 41 14.32 406 6 13
8 0.08 181 14.37 320 6 54

Cycle 117 GMT 23/ 4/2017 6:28: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.64 29 14.42 464 6 6
2 1132.28 3 8.94 2116 6 6
3 1515.24 33 10.82 2658 6 6
4 1515.00 33 11.01 2607 6 6
5 1315.44 40 12.45 2329 6 7
6 329.92 41 13.78 864 6 12
7 47.28 41 14.36 393 6 14
8 0.12 181 14.36 325 6 54

Cycle 116 GMT 13/ 4/2017 7: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 26 14.23 482 6 6
2 1077.44 2 12.25 2053 6 6
3 1037.72 1 12.38 2000 6 6
4 1173.64 3 9.54 2124 6 6
5 1289.44 33 11.35 2318 6 6
6 1289.52 33 11.46 2286 6 6
7 1090.16 40 12.72 1996 6 8
8 163.36 41 14.10 587 6 12
9 29.12 41 14.42 357 6 14
10 0.12 181 14.38 322 6 65

Cycle 115 GMT 3/ 4/2017 7:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.92 29 14.48 464 6 6
2 960.96 -1 14.48 464 6 6
3 963.80 -1 14.48 464 6 6
4 1204.64 3 8.84 2312 6 6
5 1636.32 33 10.95 2812 6 6
6 1636.20 33 10.85 2809 6 6
7 1426.12 40 12.39 2473 6 7
8 446.44 41 13.63 1022 6 11
9 65.96 41 14.32 420 6 14
10 0.08 181 14.39 318 6 51

Cycle 114 GMT 24/ 3/2017 7:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.04 29 14.42 482 6 6
2 2004.44 59 10.05 3323 6 6
3 1807.00 35 12.03 3060 6 6
4 907.80 35 13.10 1707 6 8
5 110.00 35 14.30 494 6 10
6 13.40 35 14.50 324 6 12
7 0.08 181 14.40 320 6 57

Cycle 113 GMT 14/ 3/2017 7:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.76 29 14.29 482 6 6
2 1383.24 58 11.02 2447 6 6
3 1232.76 36 12.61 2211 6 7
4 352.00 36 13.80 897 6 10
5 67.20 35 14.37 419 6 12
6 0.24 181 14.40 323 6 39

Cycle 112 GMT 4/ 3/2017 8:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 29 14.36 482 6 6
2 2002.00 58 10.37 3334 6 6
3 1600.20 36 12.37 2755 6 6
4 728.80 35 13.33 1457 6 9
5 108.16 35 14.25 501 6 12
6 22.08 35 14.47 349 6 13
7 0.04 181 14.40 326 6 61

Cycle 111 GMT 22/ 2/2017 8:20: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 29 14.36 482 6 6
2 2002.16 58 10.37 3339 6 6
3 1611.24 36 12.33 2753 6 6
4 927.52 36 13.13 1744 6 9
5 99.00 35 14.29 479 6 11
6 12.20 35 14.47 327 6 12
7 0.08 181 14.39 320 6 55

Cycle 110 GMT 12/ 2/2017 8:28: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 29 14.48 464 6 6
2 2001.84 58 10.47 3322 6 6
3 1621.16 36 12.38 2763 6 6
4 750.60 35 13.28 1504 6 9
5 122.80 35 14.21 529 6 12
6 9.36 35 14.48 328 6 12
7 0.08 181 14.36 329 6 61

Cycle 109 GMT 2/ 2/2017 8:28: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.56 29 14.48 464 6 6
2 2002.04 58 10.43 3336 6 6
3 1617.68 36 12.34 2768 6 6
4 739.36 35 13.36 1439 6 9
5 122.08 35 14.20 524 6 12
6 24.48 35 14.43 362 6 13
7 0.00 181 14.37 329 6 62

Cycle 108 GMT 23/ 1/2017 8:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 29 14.48 482 6 6
2 2002.32 58 10.48 3327 6 6
3 1617.64 36 12.35 2786 6 6
4 732.96 36 13.35 1452 6 9
5 107.16 35 14.24 509 6 12
6 9.24 35 14.45 340 6 12
7 0.12 181 14.36 329 6 65

Cycle 107 GMT 13/ 1/2017 8:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 29 14.48 482 6 6
2 2003.32 58 10.55 3351 6 6
3 1611.76 36 12.40 2734 6 6
4 728.76 35 13.35 1448 6 9
5 111.72 35 14.25 515 6 11
6 9.56 35 14.51 344 6 13
7 0.08 181 14.36 332 6 62

Cycle 106 GMT 3/ 1/2017 8:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.48 29 14.42 464 6 6
2 2007.80 58 10.61 3342 6 6
3 1604.96 36 12.43 2729 6 6
4 717.88 35 13.39 1429 6 9
5 102.80 35 14.29 498 6 12
6 9.96 35 14.47 345 6 13
7 0.08 181 14.35 338 6 64

Cycle 105 GMT 24/12/2016 9: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.56 29 14.55 464 6 6
2 2001.12 58 10.65 3334 6 6
3 1807.04 36 12.22 3041 6 6
4 867.96 36 13.22 1648 6 9
5 98.56 35 14.31 482 6 11
6 19.40 35 14.47 342 6 13
7 0.48 180 14.36 327 6 59

Cycle 104 GMT 14/12/2016 9:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.40 29 14.55 446 6 6
2 2003.60 58 10.65 3327 6 6
3 1812.48 36 12.23 3076 6 6
4 675.52 35 13.42 1382 6 9
5 101.72 35 14.29 487 6 11
6 0.16 181 14.42 321 6 32

Cycle 103 GMT 4/12/2016 9:22: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 29 14.48 464 6 6
2 2006.56 58 10.67 3337 6 6
3 1607.92 36 12.43 2744 6 6
4 719.04 36 13.39 1442 6 10
5 102.04 35 14.30 491 6 11
6 7.40 35 14.52 321 6 13
7 0.08 181 14.39 323 6 65

Cycle 102 GMT 24/11/2016 9:30:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 29 14.42 482 6 6
2 2005.68 58 10.73 3318 6 6
3 1609.40 36 12.46 2751 6 6
4 723.00 35 13.40 1419 6 9
5 107.20 35 14.27 497 6 12
6 7.36 35 14.50 327 6 14
7 0.04 181 14.37 322 6 64

Cycle 101 GMT 14/11/2016 9:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.52 29 14.42 482 6 6
2 2008.36 58 10.68 3354 6 6
3 1615.60 36 12.43 2779 6 6
4 727.20 35 13.43 1448 6 10
5 107.32 35 14.26 498 6 11
6 8.36 35 14.48 324 6 13
7 0.04 181 14.38 321 6 65

Cycle 100 GMT 4/11/2016 9:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.92 29 14.48 464 6 6
2 2003.52 58 10.77 3323 6 6
3 1602.24 36 12.50 2726 6 6
4 699.44 35 13.43 1401 6 10
5 97.08 35 14.33 480 6 11
6 0.08 180 14.42 318 6 35

Cycle 99 GMT 25/10/2016 9:30:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.68 29 14.48 482 6 6
2 2006.04 58 10.77 3356 6 6
3 1609.64 36 12.47 2763 6 6
4 697.28 35 13.42 1425 6 10
5 92.40 35 14.34 471 6 11
6 5.36 35 14.51 318 6 11
7 0.04 181 14.38 322 6 65

Cycle 98 GMT 15/10/2016 9:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 29 14.48 482 6 6
2 2006.00 58 10.84 3348 6 6
3 1609.84 36 12.50 2748 6 6
4 702.96 36 13.46 1389 6 10
5 96.08 35 14.32 485 6 11
6 0.76 180 14.40 322 6 33

Cycle 97 GMT 5/10/2016 9:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.56 29 14.55 482 6 6
2 2003.24 58 10.83 3348 6 6
3 1802.56 36 12.28 3057 6 6
4 659.20 35 13.50 1319 6 9
5 95.76 35 14.31 476 6 11
6 0.08 181 14.43 317 6 40

Cycle 96 GMT 25/ 9/2016 10: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.16 29 14.42 464 6 6
2 2004.76 58 10.80 3349 6 6
3 1616.04 36 12.49 2747 6 6
4 716.16 35 13.43 1408 6 10
5 107.60 35 14.29 497 6 11
6 0.12 181 14.40 314 6 35

Cycle 95 GMT 15/ 9/2016 9:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.08 29 14.42 464 6 6
2 2007.12 58 10.84 3340 6 6
3 1609.64 36 12.52 2754 6 6
4 712.40 35 13.45 1407 6 10
5 97.48 35 14.31 484 6 12
6 0.12 181 14.42 316 6 37

Cycle 94 GMT 5/ 9/2016 9:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.28 29 14.55 464 6 6
2 2002.84 58 10.84 3332 6 6
3 1596.44 36 12.50 2762 6 6
4 688.68 35 13.48 1370 6 10
5 92.80 35 14.33 473 6 11
6 0.20 181 14.41 314 6 41

Cycle 93 GMT 26/ 8/2016 10: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.04 28 14.48 464 6 6
2 2001.44 58 10.92 3330 6 6
3 1587.92 36 12.56 2710 6 6
4 669.76 35 13.49 1344 6 10
5 84.00 35 14.36 458 6 11
6 0.12 181 14.41 319 6 35

Cycle 92 GMT 16/ 8/2016 10:18: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.00 28 14.55 464 6 6
2 2005.96 58 10.90 3340 6 6
3 1573.12 36 12.57 2697 6 6
4 680.60 35 13.49 1342 6 10
5 90.08 35 14.32 478 6 12
6 0.68 180 14.38 326 6 36

Cycle 91 GMT 6/ 8/2016 10:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.96 28 14.55 464 6 6
2 2000.88 58 10.85 3334 6 6
3 1805.32 36 12.33 3034 6 6
4 636.20 35 13.52 1292 6 10
5 91.36 35 14.28 485 6 12
6 0.08 181 14.43 319 6 42

Cycle 90 GMT 27/ 7/2016 10:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 29 14.48 482 6 6
2 961.56 -1 14.48 482 6 6
3 1021.08 1 10.86 1946 6 6
4 2005.24 58 10.94 3354 6 6
5 1558.96 36 12.56 2699 6 6
6 652.60 35 13.52 1312 6 10
7 78.56 35 14.29 458 6 13
8 0.12 181 14.37 326 6 37

Cycle 89 GMT 17/ 7/2016 10:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.96 29 14.55 464 6 6
2 2004.60 58 10.83 3333 6 6
3 1654.24 36 12.48 2823 6 6
4 536.44 35 13.65 1144 6 10
5 75.00 35 14.37 443 6 12
6 0.08 181 14.38 322 6 32

Cycle 88 GMT 7/ 7/2016 10: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.00 29 14.48 482 6 6
2 2009.76 58 10.88 3355 6 6
3 1623.48 33 12.59 2783 6 6
4 721.92 33 13.48 1450 6 10
5 114.08 33 14.30 510 6 11
6 24.64 33 14.47 359 6 13
7 0.08 181 14.37 323 6 51

Cycle 87 GMT 27/ 6/2016 10:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.80 29 14.55 464 6 6
2 2004.28 58 10.77 3354 6 6
3 1620.44 33 12.61 2775 6 6
4 717.64 33 13.48 1439 6 9
5 107.40 33 14.28 510 6 12
6 11.60 33 14.49 339 6 13
7 0.04 181 14.33 329 6 53

Cycle 86 GMT 17/ 6/2016 10:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 29 14.55 464 6 6
2 2002.76 58 10.80 3345 6 6
3 1428.52 33 12.81 2469 6 6
4 767.76 33 13.46 1485 6 9
5 98.00 33 14.30 486 6 11
6 26.08 33 14.49 358 6 13
7 0.04 181 14.41 318 6 49

Cycle 85 GMT 7/ 6/2016 10:19: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 28 14.61 464 6 6
2 2002.28 58 10.84 3349 6 6
3 1426.16 33 12.78 2498 6 6
4 555.96 33 13.68 1176 6 9
5 95.40 33 14.32 483 6 11
6 23.64 33 14.51 347 6 13
7 0.04 181 14.40 319 6 56

Cycle 84 GMT 28/ 5/2016 10:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 28 14.48 482 6 6
2 2001.36 58 10.82 3339 6 6
3 1587.96 33 12.64 2720 6 6
4 719.12 33 13.53 1410 6 9
5 123.92 33 14.28 528 6 11
6 28.52 33 14.49 362 6 13
7 0.16 181 14.39 324 6 48

Cycle 83 GMT 18/ 5/2016 10:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.44 28 14.48 482 6 6
2 2014.48 58 10.87 3357 6 6
3 1610.76 33 12.68 2727 6 6
4 717.68 33 13.51 1415 6 9
5 110.96 33 14.29 514 6 12
6 0.12 181 14.39 323 6 31

Cycle 82 GMT 8/ 5/2016 10: 7: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.48 28 14.55 482 6 6
2 2003.20 58 10.84 3356 6 6
3 1602.56 33 12.62 2749 6 6
4 708.00 33 13.56 1395 6 9
5 106.28 33 14.31 509 6 11
6 0.12 181 14.39 327 6 34

Cycle 81 GMT 28/ 4/2016 9:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.00 28 14.61 464 6 6
2 2006.44 58 10.73 3358 6 6
3 1601.12 33 12.65 2730 6 6
4 743.20 33 13.49 1437 6 9
5 121.64 33 14.27 532 6 12
6 9.04 33 14.50 336 6 13
7 0.08 181 14.34 330 6 53

Cycle 80 GMT 18/ 4/2016 9:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 28 14.48 482 6 6
2 2001.00 60 10.75 3330 6 6
3 1419.52 32 12.83 2495 6 6
4 765.40 32 13.48 1524 6 10
5 122.32 32 14.26 537 6 11
6 0.12 181 14.40 324 6 38

Cycle 79 GMT 8/ 4/2016 10: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.32 28 14.61 464 6 6
2 2002.76 60 10.80 3335 6 6
3 1413.68 32 12.89 2444 6 6
4 744.92 32 13.52 1441 6 9
5 117.76 32 14.30 532 6 12
6 24.04 32 14.47 366 6 14
7 0.00 181 14.34 334 6 48

Cycle 78 GMT 29/ 3/2016 9:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.44 28 14.55 464 6 6
2 2000.40 50 10.88 3322 6 6
3 1633.60 33 12.70 2799 6 6
4 763.76 33 13.50 1488 6 9
5 83.64 33 14.39 469 6 11
6 18.08 33 14.48 352 6 13
7 0.08 181 14.36 328 6 48

Cycle 77 GMT 19/ 3/2016 9:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.04 28 14.61 446 6 6
2 2006.88 50 10.88 3341 6 6
3 1810.24 33 12.54 3031 6 6
4 900.64 33 13.38 1679 6 9
5 121.72 33 14.33 525 6 10
6 25.92 33 14.54 361 6 12
7 0.04 181 14.39 324 6 47

Cycle 76 GMT 9/ 3/2016 9:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.96 28 14.55 464 6 6
2 2004.80 50 10.87 3324 6 6
3 1811.08 33 12.54 3058 6 6
4 915.12 33 13.36 1705 6 8
5 132.00 33 14.27 550 6 11
6 30.52 33 14.50 366 6 12
7 0.08 181 14.38 322 6 47

Cycle 75 GMT 28/ 2/2016 9:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.00 28 14.55 464 6 6
2 2001.84 50 10.89 3328 6 6
3 1802.52 33 12.56 3057 6 6
4 889.92 33 13.39 1671 6 8
5 117.36 33 14.31 525 6 11
6 26.12 33 14.49 369 6 12
7 0.08 181 14.37 326 6 46

Cycle 74 GMT 18/ 2/2016 9:30: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.64 28 14.48 482 6 6
2 2004.64 50 10.88 3345 6 6
3 1807.08 33 12.57 3031 6 6
4 915.76 33 13.36 1709 6 8
5 125.76 33 14.28 555 6 11
6 30.16 33 14.50 384 6 13
7 0.12 181 14.37 332 6 47

Cycle 73 GMT 8/ 2/2016 9:24: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.64 28 14.55 482 6 6
2 2001.76 50 10.87 3346 6 6
3 1804.20 33 12.59 3015 6 6
4 917.36 33 13.36 1726 6 8
5 121.00 33 14.32 541 6 10
6 26.80 33 14.50 378 6 12
7 0.04 181 14.37 334 6 47

Cycle 72 GMT 29/ 1/2016 9:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.84 28 14.61 482 6 6
2 2003.32 50 10.89 3340 6 6
3 1805.92 33 12.56 3055 6 6
4 897.48 33 13.39 1682 6 8
5 119.44 33 14.33 529 6 11
6 23.56 33 14.49 365 6 13
7 0.04 180 14.36 332 6 44

Cycle 71 GMT 19/ 1/2016 9:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.52 28 14.55 464 6 6
2 2001.64 50 10.89 3359 6 6
3 1813.56 33 12.54 3093 6 6
4 914.44 33 13.41 1712 6 8
5 124.64 33 14.32 539 6 10
6 24.48 33 14.52 366 6 12
7 0.04 181 14.37 331 6 46

Cycle 70 GMT 9/ 1/2016 9:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.28 28 14.55 482 6 6
2 2007.04 50 10.98 3357 6 6
3 1808.80 33 12.56 3061 6 6
4 907.72 33 13.36 1783 6 9
5 113.16 33 14.36 520 6 10
6 9.72 33 14.52 347 6 12
7 0.12 181 14.34 333 6 48

Cycle 69 GMT 30/12/2015 9:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.88 28 14.61 464 6 6
2 1991.32 50 10.97 3349 6 6
3 1806.88 33 12.59 3035 6 6
4 915.00 33 13.38 1709 6 8
5 120.72 33 14.35 530 6 10
6 11.52 33 14.54 348 6 12
7 0.12 181 14.34 333 6 44

Cycle 68 GMT 20/12/2015 8:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.48 28 14.61 464 6 6
2 2001.76 50 10.92 3359 6 6
3 1626.08 33 12.73 2790 6 6
4 780.68 33 13.53 1514 6 9
5 144.92 33 14.27 586 6 11
6 2.04 33 14.53 336 6 11
7 0.08 180 14.33 334 6 46

Cycle 67 GMT 10/12/2015 8: 2: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.48 28 14.55 500 6 6
2 2006.08 50 10.90 3360 6 6
3 1633.76 33 12.76 2805 6 6
4 956.08 33 13.37 1783 6 9
5 123.64 33 14.34 539 6 11
6 13.72 33 14.53 350 6 12
7 0.12 181 14.32 335 6 46

Cycle 66 GMT 30/11/2015 8: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.12 28 14.68 482 6 6
2 2002.36 35 11.01 3371 6 6
3 1842.60 20 12.83 3149 6 6
4 1640.96 20 13.03 2825 6 6
5 1183.76 20 13.35 2133 6 7
6 506.40 20 13.87 1140 6 9
7 138.08 20 14.33 564 6 10
8 33.80 21 14.51 388 6 10
9 0.08 191 14.36 331 6 41

Cycle 65 GMT 20/11/2015 7:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.56 28 14.61 482 6 6
2 2006.60 35 11.03 3376 6 6
3 1848.08 20 12.85 3151 6 6
4 1648.60 20 13.03 2783 6 6
5 1186.20 20 13.39 2095 6 7
6 507.40 20 13.87 1138 6 9
7 138.88 20 14.31 568 6 10
8 66.32 21 14.45 442 6 11
9 0.08 190 14.35 334 6 37

Cycle 64 GMT 10/11/2015 7:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.96 28 14.55 482 6 6
2 2001.60 35 11.11 3399 6 6
3 1848.40 20 12.87 3182 6 6
4 1631.00 20 13.04 2841 6 6
5 976.96 20 13.51 1814 6 7
6 531.28 20 13.89 1160 6 9
7 133.80 20 14.32 568 6 10
8 63.76 21 14.40 440 6 12
9 0.08 190 14.32 337 6 41

Cycle 63 GMT 31/10/2015 7:51:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 28 14.55 500 6 6
2 2001.88 35 11.21 3404 6 6
3 1839.24 20 12.86 3115 6 6
4 1624.44 20 13.08 2756 6 6
5 1168.16 20 13.37 2088 6 7
6 487.24 20 13.93 1104 6 9
7 125.84 21 14.32 557 6 10
8 60.60 21 14.44 446 6 12
9 0.16 190 14.33 344 6 39

Cycle 62 GMT 21/10/2015 8: 5: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.36 28 14.55 500 6 6
2 2002.36 35 11.26 3416 6 6
3 1846.40 20 12.85 3146 6 6
4 1636.92 20 13.10 2767 6 6
5 1178.68 20 13.44 2068 6 7
6 488.84 20 13.90 1135 6 9
7 129.40 20 14.35 544 6 10
8 64.12 21 14.46 430 6 11
9 0.08 190 14.35 334 6 40

Cycle 61 GMT 11/10/2015 8:15: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.32 28 14.68 482 6 6
2 2001.16 35 11.39 3392 6 6
3 1831.96 20 12.92 3102 6 6
4 1623.32 20 13.10 2814 6 6
5 954.92 20 13.57 1803 6 7
6 507.92 20 13.93 1149 6 10
7 129.04 21 14.35 547 6 10
8 58.56 21 14.44 426 6 12
9 0.00 190 14.31 339 6 44

Cycle 60 GMT 1/10/2015 8:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.36 28 14.61 482 6 6
2 2007.16 35 11.58 3401 6 6
3 1847.60 20 12.88 3129 6 6
4 1632.32 20 13.10 2787 6 6
5 1183.80 20 13.45 2117 6 7
6 484.48 20 13.93 1120 6 9
7 118.20 21 14.37 525 6 10
8 56.16 21 14.44 420 6 11
9 0.20 191 14.36 327 6 44

Cycle 59 GMT 21/ 9/2015 8:44: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.48 28 14.61 482 6 6
2 2000.80 36 11.73 3384 6 6
3 1830.12 20 12.91 3104 6 6
4 1427.48 20 13.26 2486 6 6
5 1000.40 20 13.55 1856 6 7
6 334.08 20 14.07 903 6 10
7 90.72 20 14.44 477 6 9
8 42.04 20 14.52 389 6 10
9 0.12 190 14.33 331 6 39

Cycle 58 GMT 11/ 9/2015 8:41: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.64 28 14.61 482 6 6
2 2003.04 36 11.83 3388 6 6
3 1831.60 21 12.91 3088 6 6
4 1623.76 21 13.09 2757 6 6
5 942.36 20 13.59 1760 6 7
6 475.68 20 13.95 1104 6 11
7 108.40 20 14.38 515 6 10
8 49.60 20 14.45 412 6 11
9 0.04 190 14.31 330 6 38

Cycle 57 GMT 1/ 9/2015 8:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.64 28 14.61 482 6 6
2 2001.92 36 12.00 3383 6 6
3 1830.88 21 12.89 3162 6 6
4 1612.24 21 13.13 2741 6 6
5 922.88 20 13.63 1705 6 7
6 259.56 20 14.18 771 6 10
7 65.84 20 14.47 434 6 10
8 14.84 20 14.51 345 6 11
9 0.08 190 14.30 325 6 43

Cycle 56 GMT 22/ 8/2015 9: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 28 14.61 482 6 6
2 2000.52 36 12.05 3384 6 6
3 1820.16 21 12.98 3078 6 6
4 1408.60 20 13.32 2437 6 6
5 959.20 20 13.62 1791 6 8
6 287.92 20 14.16 818 6 10
7 80.40 20 14.43 459 6 10
8 0.12 190 14.38 322 6 33

Cycle 55 GMT 12/ 8/2015 8:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.64 28 14.55 482 6 6
2 2006.48 36 12.25 3397 6 6
3 1823.88 20 12.99 3120 6 6
4 1615.72 21 13.12 2763 6 6
5 938.36 20 13.64 1716 6 7
6 479.16 20 13.99 1077 6 10
7 109.96 20 14.41 506 6 10
8 55.60 20 14.44 421 6 11
9 0.08 191 14.32 325 6 43

Cycle 54 GMT 2/ 8/2015 9: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.08 28 14.61 482 6 6
2 2007.44 36 12.36 3397 6 6
3 1822.20 20 13.03 3082 6 6
4 1404.00 20 13.34 2417 6 6
5 961.36 20 13.65 1753 6 7
6 502.32 20 13.95 1131 6 10
7 113.24 20 14.40 517 6 10
8 25.48 20 14.48 363 6 11
9 0.04 190 14.31 327 6 45

Cycle 53 GMT 23/ 7/2015 9: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.08 28 14.61 482 6 6
2 2002.28 36 12.56 3358 6 6
3 1835.44 20 13.00 3133 6 6
4 1615.76 20 13.23 2720 6 6
5 942.12 20 13.62 1718 6 7
6 283.04 21 14.17 805 6 10
7 74.08 21 14.46 444 6 10
8 0.12 190 14.36 319 6 36

Cycle 52 GMT 13/ 7/2015 9:18: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.96 28 14.68 482 6 6
2 2002.88 36 12.65 3383 6 6
3 1829.32 20 13.11 3039 6 6
4 1620.72 20 13.22 2752 6 6
5 934.28 20 13.66 1756 6 7
6 471.36 21 13.98 1095 6 10
7 97.28 21 14.41 488 6 10
8 44.16 21 14.44 402 6 12
9 0.12 190 14.32 323 6 44

Cycle 51 GMT 3/ 7/2015 9:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.44 28 14.61 464 6 6
2 2002.32 36 12.75 3346 6 6
3 1820.68 20 13.10 3075 6 6
4 1396.80 20 13.39 2410 6 6
5 948.12 21 13.64 1729 6 8
6 280.52 21 14.19 803 6 11
7 73.68 21 14.51 450 6 10
8 0.12 191 14.38 319 6 40

Cycle 50 GMT 23/ 6/2015 9:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.00 28 14.68 482 6 6
2 2007.04 36 12.84 3377 6 6
3 1821.40 20 13.10 3064 6 6
4 1393.72 20 13.40 2405 6 6
5 943.76 21 13.66 1715 6 8
6 271.44 21 14.18 797 6 11
7 59.48 21 14.48 426 6 10
8 27.92 21 14.48 369 6 11
9 0.20 190 14.33 324 6 48

Cycle 49 GMT 13/ 6/2015 9:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 28 14.68 482 6 6
2 2002.44 36 12.91 3379 6 6
3 1823.24 20 13.11 3088 6 6
4 1387.88 20 13.40 2432 6 7
5 943.20 21 13.66 1739 6 8
6 266.80 21 14.26 773 6 11
7 64.80 21 14.51 428 6 10
8 30.84 21 14.52 367 6 11
9 0.04 191 14.35 320 6 50

Cycle 48 GMT 3/ 6/2015 10: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.36 28 14.68 482 6 6
2 2001.44 36 12.92 3379 6 6
3 1818.60 20 13.13 3088 6 6
4 1396.12 21 13.37 2414 6 7
5 936.52 21 13.67 1737 6 8
6 239.92 21 14.26 740 6 11
7 59.96 21 14.53 422 6 10
8 0.16 191 14.38 325 6 36

Cycle 47 GMT 24/ 5/2015 10:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.52 28 14.68 482 6 6
2 2006.12 36 12.95 3379 6 6
3 1815.20 20 13.16 3079 6 6
4 1384.32 21 13.38 2392 6 6
5 933.80 21 13.66 1737 6 8
6 242.00 21 14.24 753 6 12
7 62.96 21 14.54 420 6 10
8 32.80 21 14.49 376 6 12
9 0.12 190 14.34 327 6 44

Cycle 46 GMT 14/ 5/2015 10:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.52 28 14.68 464 6 6
2 2005.36 36 13.00 3371 6 6
3 1823.92 20 13.17 3079 6 6
4 1395.00 21 13.39 2402 6 6
5 736.40 21 13.83 1449 6 8
6 283.84 21 14.22 815 6 11
7 66.24 21 14.49 438 6 10
8 33.16 21 14.46 378 6 12
9 0.12 190 14.35 327 6 51

Cycle 45 GMT 4/ 5/2015 10: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.84 28 14.68 464 6 6
2 2004.56 36 13.03 3371 6 6
3 1811.24 20 13.20 3035 6 6
4 1592.72 20 13.36 2673 6 6
5 910.00 21 13.72 1707 6 8
6 229.76 21 14.30 720 6 11
7 61.16 21 14.54 420 6 10
8 33.60 21 14.54 372 6 11
9 0.08 190 14.36 324 6 50

Cycle 44 GMT 24/ 4/2015 10:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.64 28 14.68 482 6 6
2 2002.28 36 13.04 3380 6 6
3 1817.00 20 13.19 3095 6 6
4 1598.20 20 13.34 2716 6 6
5 901.96 21 13.72 1691 6 8
6 221.96 21 14.34 702 6 11
7 55.72 21 14.53 420 6 10
8 26.88 21 14.52 364 6 12
9 0.08 190 14.36 323 6 50

Cycle 43 GMT 14/ 4/2015 10:15: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.32 28 14.74 482 6 6
2 2002.48 36 13.08 3371 6 6
3 1818.68 20 13.24 3064 6 6
4 1603.76 21 13.33 2686 6 6
5 703.24 21 13.90 1382 6 8
6 260.60 21 14.28 773 6 11
7 66.60 21 14.56 434 6 10
8 14.40 21 14.61 343 6 11
9 0.16 190 14.36 323 6 49

Cycle 42 GMT 4/ 4/2015 10: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.60 28 14.68 500 6 6
2 2002.84 36 13.06 3345 6 6
3 1815.92 20 13.23 3044 6 6
4 1374.04 21 13.44 2410 6 6
5 708.64 21 13.93 1386 6 8
6 261.00 21 14.29 777 6 11
7 64.12 21 14.56 428 6 10
8 13.80 21 14.55 345 6 11
9 0.08 190 14.37 319 6 51

Cycle 41 GMT 25/ 3/2015 10: 0: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.32 28 14.68 500 6 6
2 2001.00 36 13.07 3375 6 6
3 1817.36 20 13.21 3091 6 6
4 1392.96 21 13.44 2426 6 7
5 714.76 21 13.93 1376 6 8
6 265.92 21 14.29 791 6 11
7 76.68 21 14.58 440 6 10
8 35.44 21 14.58 378 6 11
9 0.16 190 14.39 319 6 50

Cycle 40 GMT 15/ 3/2015 10:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.92 28 14.74 482 6 6
2 2004.68 36 13.03 3395 6 6
3 1823.44 20 13.22 3106 6 6
4 1391.72 21 13.48 2386 6 7
5 929.36 21 13.78 1715 6 8
6 231.16 21 14.35 736 6 11
7 108.60 21 14.50 507 6 11
8 52.32 21 14.55 408 6 12
9 0.04 190 14.38 323 6 48

Cycle 39 GMT 5/ 3/2015 10:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.00 28 14.68 500 6 6
2 2000.80 36 13.03 3357 6 6
3 1824.52 20 13.24 3120 6 6
4 1401.76 21 13.46 2432 6 7
5 734.00 21 13.93 1418 6 8
6 266.20 21 14.27 801 6 12
7 73.00 21 14.57 446 6 10
8 15.44 21 14.62 343 6 11
9 0.20 190 14.39 325 6 50

Cycle 38 GMT 23/ 2/2015 10:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.36 28 14.68 500 6 6
2 2003.60 36 13.00 3388 6 6
3 1831.88 21 13.21 3049 6 6
4 1617.76 21 13.35 2716 6 6
5 696.40 21 13.97 1364 6 8
6 253.92 21 14.31 775 6 11
7 76.16 21 14.59 456 6 10
8 37.68 21 14.60 378 6 12
9 0.12 190 14.40 330 6 52

Cycle 37 GMT 13/ 2/2015 10:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.32 28 14.74 482 6 6
2 2000.44 36 12.99 3364 6 6
3 1816.08 21 13.22 3063 6 6
4 1387.72 21 13.50 2404 6 6
5 726.76 21 13.92 1414 6 8
6 154.64 21 14.45 601 6 11
7 83.76 21 14.54 472 6 11
8 17.72 20 14.62 359 6 11
9 0.08 190 14.41 329 6 45

Cycle 36 GMT 3/ 2/2015 10: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 28 14.74 482 6 6
2 2000.84 36 12.98 3386 6 6
3 1823.84 21 13.20 3106 6 6
4 1202.12 21 13.61 2124 6 7
5 754.04 21 13.94 1465 6 8
6 154.20 20 14.47 604 6 10
7 89.52 20 14.56 484 6 11
8 42.92 20 14.60 403 6 11
9 0.16 190 14.40 331 6 45

Cycle 35 GMT 24/ 1/2015 10:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.28 27 14.74 482 6 6
2 2004.76 36 12.97 3378 6 6
3 1835.00 21 13.20 3106 6 6
4 1408.36 21 13.50 2416 6 7
5 726.56 21 13.96 1438 6 8
6 150.32 20 14.49 595 6 10
7 84.36 20 14.57 470 6 10
8 39.56 20 14.59 401 6 11
9 0.12 190 14.40 333 6 45

Cycle 34 GMT 14/ 1/2015 10: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.00 27 14.68 517 6 6
2 2008.52 36 12.94 3375 6 6
3 1835.64 21 13.17 3140 6 6
4 1378.64 21 13.49 2388 6 6
5 922.92 21 13.80 1709 6 8
6 213.36 20 14.37 729 6 12
7 109.20 20 14.54 515 6 11
8 20.08 20 14.66 361 6 11
9 0.16 190 14.40 336 6 46

Cycle 33 GMT 4/ 1/2015 10: 6: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 27 14.74 482 6 6
2 2001.96 36 12.91 3377 6 6
3 1802.88 21 13.16 3100 6 6
4 1361.64 21 13.47 2382 6 7
5 901.32 21 13.81 1689 6 9
6 196.80 20 14.40 696 6 11
7 102.00 20 14.54 508 6 11
8 19.72 20 14.64 368 6 11
9 0.08 190 14.41 339 6 45

Cycle 32 GMT 25/12/2014 10: 6:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.20 27 14.74 500 6 6
2 2002.64 36 12.85 3392 6 6
3 1794.44 21 13.17 3061 6 6
4 1339.36 21 13.48 2336 6 6
5 654.88 21 14.01 1320 6 8
6 199.08 20 14.41 693 6 11
7 109.64 20 14.54 519 6 11
8 27.00 21 14.66 378 6 11
9 0.08 190 14.42 335 6 49

Cycle 31 GMT 15/12/2014 10: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.56 27 14.68 482 6 6
2 2005.08 36 12.85 3377 6 6
3 1827.60 21 13.17 3037 6 6
4 1212.80 21 13.59 2114 6 6
5 768.80 21 13.95 1460 6 8
6 174.28 20 14.49 622 6 10
7 96.64 20 14.60 484 6 10
8 21.48 20 14.72 352 6 10
9 0.20 190 14.45 326 6 46

Cycle 30 GMT 5/12/2014 9:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.16 27 14.74 500 6 6
2 2001.36 36 12.86 3370 6 6
3 1787.00 21 13.15 3017 6 6
4 1567.60 21 13.37 2620 6 7
5 859.24 21 13.85 1610 6 8
6 189.36 20 14.43 662 6 11
7 96.44 20 14.60 486 6 10
8 23.40 21 14.67 363 6 11
9 0.12 190 14.43 329 6 45

Cycle 29 GMT 25/11/2014 9:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.12 27 14.74 482 6 6
2 2003.12 36 12.91 3389 6 6
3 1813.24 21 13.14 3083 6 6
4 1354.76 21 13.49 2384 6 6
5 696.04 21 13.98 1382 6 8
6 159.76 21 14.51 605 6 10
7 84.76 21 14.61 468 6 10
8 2.88 20 14.75 332 6 11
9 0.08 191 14.45 333 6 48

Cycle 28 GMT 15/11/2014 10: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.60 27 14.74 482 6 6
2 2010.24 36 12.92 3360 6 6
3 1819.04 21 13.16 3045 6 6
4 1345.96 21 13.49 2339 6 7
5 869.48 21 13.85 1632 6 8
6 177.80 20 14.47 646 6 11
7 96.44 20 14.58 493 6 11
8 20.00 20 14.67 363 6 11
9 0.12 191 14.43 336 6 44

Cycle 27 GMT 5/11/2014 10:10:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.44 27 14.74 464 6 6
2 2005.64 36 12.96 3371 6 6
3 1817.36 21 13.18 3080 6 6
4 1366.64 21 13.51 2350 6 6
5 920.16 21 13.83 1704 6 8
6 221.24 20 14.42 716 6 11
7 69.56 21 14.64 434 6 10
8 33.80 21 14.67 371 6 11
9 0.08 190 14.44 321 6 48

Cycle 26 GMT 26/10/2014 10:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 27 14.80 482 6 6
2 2002.24 36 12.97 3367 6 6
3 1828.52 21 13.17 3073 6 6
4 1381.48 21 13.52 2384 6 6
5 701.36 21 14.00 1382 6 8
6 234.80 21 14.39 739 6 11
7 55.44 21 14.67 418 6 10
8 11.72 21 14.69 339 6 10
9 0.04 190 14.42 322 6 55

Cycle 25 GMT 16/10/2014 10:35:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.16 27 14.74 482 6 6
2 2000.96 36 12.98 3388 6 6
3 1806.36 21 13.19 3049 6 6
4 1363.40 21 13.52 2350 6 7
5 899.08 21 13.87 1652 6 9
6 189.68 20 14.47 657 6 11
7 94.36 21 14.59 484 6 11
8 5.08 20 14.74 325 6 10
9 0.16 201 14.44 322 6 63

Cycle 24 GMT 6/10/2014 10:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 27 14.68 500 6 6
2 2001.32 36 13.01 3358 6 6
3 1812.24 20 13.27 3022 6 6
4 1383.48 21 13.51 2394 6 6
5 923.68 21 13.87 1733 6 8
6 212.40 21 14.45 702 6 11
7 54.20 21 14.67 420 6 10
8 27.72 21 14.65 372 6 12
9 0.08 200 14.44 325 6 69

Cycle 23 GMT 26/ 9/2014 11: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.28 27 14.74 482 6 6
2 2001.28 36 13.04 3342 6 6
3 1817.84 21 13.21 3025 6 6
4 1355.72 21 13.55 2342 6 7
5 678.04 21 14.04 1344 6 8
6 215.12 21 14.45 706 6 11
7 47.28 21 14.67 408 6 11
8 6.24 20 14.69 336 6 12
9 0.08 200 14.40 328 6 74

Cycle 22 GMT 16/ 9/2014 11:21: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.64 27 14.80 482 6 6
2 2003.84 36 13.07 3363 6 6
3 1814.12 21 13.23 3079 6 6
4 1361.80 21 13.56 2350 6 6
5 677.52 21 14.05 1356 6 9
6 216.92 20 14.49 698 6 10
7 57.88 20 14.73 412 6 10
8 0.12 201 14.48 328 6 41

Cycle 21 GMT 6/ 9/2014 11:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 27 14.80 482 6 6
2 2003.48 36 13.11 3355 6 6
3 1808.20 21 13.25 3039 6 6
4 1359.56 21 13.58 2345 6 7
5 687.04 21 14.06 1378 6 9
6 227.96 20 14.48 725 6 10
7 55.20 20 14.71 423 6 10
8 0.20 201 14.48 327 6 42

Cycle 20 GMT 27/ 8/2014 11:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.32 27 14.80 482 6 6
2 2004.44 36 13.11 3360 6 6
3 1816.64 21 13.22 3086 6 6
4 1385.20 21 13.56 2376 6 7
5 704.88 21 14.04 1382 6 9
6 245.88 20 14.46 749 6 10
7 55.36 21 14.72 418 6 10
8 0.08 201 14.49 328 6 45

Cycle 19 GMT 17/ 8/2014 11:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 27 14.80 464 6 6
2 2006.68 36 13.09 3380 6 6
3 1831.04 21 13.21 3071 6 6
4 1394.60 21 13.56 2404 6 6
5 930.52 21 13.88 1707 6 9
6 217.20 21 14.49 706 6 11
7 51.68 21 14.75 416 6 10
8 0.24 201 14.49 327 6 46

Cycle 18 GMT 7/ 8/2014 12: 5: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.76 27 14.74 482 6 6
2 1227.36 36 13.59 2255 6 6
3 1125.84 21 13.67 2051 6 6
4 929.92 21 13.86 1725 6 7
5 484.92 21 14.21 1093 6 10
6 108.12 21 14.62 519 6 10
7 49.56 21 14.67 414 6 12
8 0.08 201 14.47 327 6 56

Cycle 17 GMT 28/ 7/2014 12:48: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.00 27 14.80 482 6 6
2 1818.08 36 13.32 3040 6 6
3 1639.72 21 13.36 2791 6 6
4 1210.52 21 13.69 2106 6 7
5 755.32 21 13.99 1459 6 10
6 146.72 21 14.59 581 6 10
7 68.16 21 14.68 450 6 11
8 0.08 201 14.50 327 6 44

Cycle 16 GMT 18/ 7/2014 12:11: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 27 14.80 482 6 6
2 2003.56 36 13.24 3335 6 6
3 1799.88 21 13.30 3031 6 6
4 1363.08 21 13.60 2345 6 7
5 684.60 21 14.08 1360 6 8
6 224.36 20 14.52 714 6 10
7 56.88 21 14.77 418 6 10
8 11.52 20 14.79 348 6 12
9 0.12 201 14.48 327 6 71

Cycle 15 GMT 8/ 7/2014 12:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 27 14.80 464 6 6
2 2002.20 36 13.25 3334 6 6
3 1806.32 21 13.32 3021 6 6
4 1355.00 21 13.62 2305 6 7
5 679.52 21 14.08 1382 6 9
6 218.32 21 14.52 708 6 10
7 51.76 20 14.77 419 6 10
8 0.12 201 14.53 326 6 43

Cycle 14 GMT 28/ 6/2014 12:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.84 27 14.87 500 6 6
2 2001.04 70 12.93 3336 6 7
3 1034.00 25 13.77 1885 6 8
4 341.80 25 14.35 910 6 10
5 66.52 25 14.74 446 6 10
6 0.08 229 14.50 331 6 171

Cycle 13 GMT 18/ 6/2014 12:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.80 27 14.80 500 6 6
2 2002.32 70 12.95 3340 6 6
3 1051.16 25 13.79 1879 6 8
4 342.32 25 14.34 919 6 11
5 69.60 24 14.74 451 6 10
6 0.08 229 14.50 330 6 150

Cycle 12 GMT 8/ 6/2014 12:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.24 26 14.87 482 6 6
2 2002.20 70 12.97 3300 6 7
3 1029.56 25 13.78 1867 6 7
4 339.80 24 14.35 913 6 10
5 63.52 25 14.74 440 6 11
6 0.04 231 14.48 333 6 225

Cycle 11 GMT 29/ 5/2014 13:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.48 26 14.80 482 6 6
2 2003.56 70 12.98 3334 6 7
3 1015.80 25 13.80 1858 6 8
4 313.08 25 14.38 869 6 11
5 59.48 24 14.75 433 6 10
6 0.08 229 14.49 333 6 169

Cycle 10 GMT 19/ 5/2014 13:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.92 26 14.87 500 6 6
2 2000.88 70 12.99 3302 6 7
3 1014.68 25 13.80 1846 6 8
4 310.56 25 14.39 871 6 11
5 68.64 24 14.76 447 6 11
6 13.20 24 14.80 351 6 12
7 0.04 205 14.46 333 6 205

Cycle 9 GMT 9/ 5/2014 13:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.00 26 14.87 482 6 6
2 2009.88 70 12.99 3308 6 7
3 1032.24 25 13.78 1881 6 8
4 333.72 25 14.37 910 6 11
5 71.28 24 14.76 451 6 11
6 35.52 25 14.74 395 6 12
7 0.12 205 14.48 333 6 155

Cycle 8 GMT 29/ 4/2014 14:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.88 26 14.87 500 6 6
2 2006.00 70 13.00 3288 6 6
3 1035.60 25 13.75 1874 6 8
4 320.16 24 14.37 892 6 11
5 57.24 25 14.74 451 6 11
6 0.08 231 14.43 350 6 197

Cycle 7 GMT 19/ 4/2014 14:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.60 26 14.87 517 6 6
2 2001.00 70 12.97 3354 6 7
3 990.96 25 13.80 1815 6 8
4 302.96 25 14.39 863 6 11
5 73.40 25 14.76 471 6 10
6 15.52 24 14.80 369 6 11
7 0.16 205 14.44 339 6 177

Cycle 6 GMT 9/ 4/2014 14:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 24 14.87 500 6 6
2 1069.00 2 14.68 2035 6 6
3 2003.48 70 12.97 3290 6 7
4 1036.88 25 13.74 1888 6 8
5 334.20 25 14.34 906 6 11
6 83.92 24 14.73 482 6 10
7 2.36 24 14.85 348 6 11
8 0.12 207 14.47 345 6 184

Cycle 5 GMT 30/ 3/2014 14:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.76 29 14.87 464 6 6
2 832.40 -3 14.87 464 6 6
3 922.84 -1 14.87 464 6 6
4 2004.04 70 12.94 3303 6 6
5 1035.08 25 13.73 1862 6 7
6 340.24 24 14.33 920 6 10
7 79.60 24 14.74 483 6 10
8 17.48 24 14.80 367 6 11
9 0.12 210 14.45 345 6

Cycle 4 GMT 20/ 3/2014 14:41: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.24 25 14.80 464 6 6
2 1511.16 70 13.24 2606 6 6
3 595.08 25 14.07 1269 6 9
4 167.32 25 14.61 615 6 9
5 35.20 24 14.79 386 6 10
6 0.08 221 14.44 327 6 159

Cycle 3 GMT 19/ 3/2014 15: 7: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.44 24 14.80 500 6 6
2 1033.12 1 14.55 2000 6 6
3 1512.04 70 13.20 2604 6 7
4 813.68 25 13.85 1554 6 8
5 156.12 24 14.58 590 6 9
6 39.24 25 14.77 392 6 10
7 0.12 223 14.48 319 6

Cycle 2 GMT 18/ 3/2014 15:40: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.52 29 14.68 500 6 6
2 825.04 -3 14.68 500 6 6
3 921.60 -1 14.68 500 6 6
4 1501.72 70 13.12 2574 6 7
5 808.56 25 13.85 1529 6 7
6 161.72 24 14.51 614 6 9
7 73.84 25 14.63 455 6 10
8 0.08 223 14.43 321 6 158

Cycle 1 GMT 17/ 3/2014 16: 7: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 29 14.80 464 6 6
2 817.36 -3 14.80 464 6 6
3 926.60 -1 14.80 464 6 6
4 962.00 70 13.38 1792 6 8
5 86.52 24 14.59 482 6 9
6 39.88 24 14.65 395 6 10
7 0.20 215 14.37 329 6 243

Cycle 0 GMT 17/ 3/2014 4:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 121.20 70 14.38 486 228 6
2 100.92 25 14.71 469 6 6
3 55.80 25 14.79 395 6 6
4 0.20 223 14.66 296 6 163