SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.64 | 42 | 10.47 | 942 | 7 | 7 |
2 | 1003.92 | 70 | 8.14 | 2378 | 6 | 6 |
3 | 658.04 | 35 | 8.91 | 1907 | 6 | 6 |
4 | 131.92 | 35 | 10.07 | 1068 | 6 | 6 |
5 | 0.04 | 181 | 10.49 | 765 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.76 | 41 | 10.41 | 942 | 7 | 7 |
2 | 1165.00 | 24 | 7.83 | 2670 | 6 | 6 |
3 | 1791.80 | 41 | 6.92 | 3547 | 6 | 6 |
4 | 1787.24 | 71 | 7.00 | 3558 | 6 | 6 |
5 | 1430.96 | 35 | 7.61 | 3069 | 6 | 6 |
6 | 908.40 | 35 | 8.51 | 2323 | 6 | 6 |
7 | 386.48 | 35 | 9.51 | 1542 | 6 | 6 |
8 | 40.32 | 35 | 10.29 | 948 | 6 | 6 |
9 | 0.12 | 181 | 10.47 | 805 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.88 | 42 | 10.54 | 865 | 7 | 7 |
2 | 979.08 | 70 | 8.27 | 2327 | 7 | 6 |
3 | 481.44 | 35 | 9.27 | 1631 | 6 | 6 |
4 | 74.44 | 35 | 10.27 | 958 | 6 | 6 |
5 | 0.00 | 181 | 10.51 | 762 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.04 | 41 | 10.60 | 903 | 7 | 7 |
2 | 1005.96 | 70 | 8.27 | 2386 | 6 | 6 |
3 | 502.64 | 35 | 9.26 | 1695 | 6 | 6 |
4 | 82.00 | 35 | 10.30 | 974 | 6 | 6 |
5 | 0.00 | 181 | 10.55 | 760 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.00 | 41 | 10.66 | 923 | 7 | 7 |
2 | 1003.40 | 70 | 8.33 | 2397 | 6 | 6 |
3 | 837.00 | 35 | 8.70 | 2191 | 6 | 6 |
4 | 129.92 | 35 | 10.18 | 1083 | 6 | 6 |
5 | 0.08 | 181 | 10.55 | 773 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.04 | 41 | 10.54 | 923 | 7 | 7 |
2 | 1162.12 | 23 | 8.22 | 2664 | 6 | 6 |
3 | 1794.64 | 29 | 7.25 | 3584 | 6 | 6 |
4 | 1791.80 | 70 | 7.35 | 3547 | 6 | 6 |
5 | 1295.12 | 35 | 8.04 | 2914 | 6 | 6 |
6 | 619.00 | 35 | 9.18 | 1913 | 6 | 6 |
7 | 273.00 | 35 | 9.86 | 1370 | 6 | 6 |
8 | 4.24 | 35 | 10.50 | 873 | 6 | 6 |
9 | 0.04 | 180 | 10.54 | 800 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.00 | 41 | 10.60 | 923 | 7 | 7 |
2 | 1008.64 | 70 | 8.43 | 2398 | 6 | 6 |
3 | 495.60 | 35 | 9.36 | 1686 | 6 | 6 |
4 | 134.16 | 35 | 10.23 | 1066 | 6 | 6 |
5 | 24.04 | 35 | 10.44 | 867 | 6 | 7 |
6 | 0.00 | 181 | 10.56 | 768 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.28 | 41 | 10.60 | 884 | 7 | 7 |
2 | 1015.40 | 70 | 8.47 | 2403 | 6 | 6 |
3 | 494.92 | 35 | 9.43 | 1689 | 6 | 6 |
4 | 84.40 | 35 | 10.38 | 977 | 6 | 6 |
5 | 0.08 | 181 | 10.60 | 759 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.08 | 41 | 10.66 | 903 | 7 | 7 |
2 | 1004.68 | 70 | 8.53 | 2413 | 6 | 6 |
3 | 492.64 | 35 | 9.43 | 1707 | 6 | 6 |
4 | 76.08 | 35 | 10.38 | 983 | 6 | 6 |
5 | 0.16 | 180 | 10.59 | 777 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 41 | 10.54 | 903 | 7 | 7 |
2 | 1159.88 | 14 | 8.37 | 2720 | 6 | 6 |
3 | 1953.08 | 29 | 7.19 | 3852 | 6 | 6 |
4 | 1951.00 | 71 | 7.36 | 3789 | 6 | 6 |
5 | 1785.00 | 35 | 7.70 | 3558 | 6 | 6 |
6 | 1260.04 | 35 | 8.38 | 2836 | 6 | 6 |
7 | 558.12 | 35 | 9.46 | 1807 | 6 | 6 |
8 | 96.12 | 35 | 10.33 | 1050 | 6 | 6 |
9 | 0.12 | 181 | 10.58 | 820 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.84 | 41 | 10.60 | 884 | 7 | 7 |
2 | 1007.00 | 70 | 8.61 | 2396 | 7 | 6 |
3 | 476.44 | 35 | 9.55 | 1658 | 6 | 6 |
4 | 69.04 | 35 | 10.43 | 958 | 6 | 6 |
5 | 0.12 | 181 | 10.60 | 775 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.00 | 41 | 10.73 | 884 | 7 | 7 |
2 | 1007.28 | 70 | 8.61 | 2420 | 6 | 6 |
3 | 484.40 | 35 | 9.56 | 1679 | 6 | 6 |
4 | 69.32 | 35 | 10.44 | 959 | 6 | 6 |
5 | 0.08 | 181 | 10.63 | 752 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.20 | 41 | 10.66 | 903 | 7 | 7 |
2 | 1012.64 | 70 | 8.66 | 2447 | 6 | 6 |
3 | 483.48 | 35 | 9.57 | 1716 | 6 | 6 |
4 | 71.72 | 35 | 10.41 | 1003 | 6 | 6 |
5 | 0.12 | 181 | 10.63 | 780 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.32 | 40 | 10.54 | 903 | 7 | 7 |
2 | 1162.76 | 14 | 8.55 | 2733 | 6 | 6 |
3 | 1959.76 | 20 | 7.50 | 3833 | 6 | 6 |
4 | 1958.48 | 71 | 7.58 | 3840 | 6 | 6 |
5 | 1797.84 | 35 | 7.77 | 3656 | 6 | 6 |
6 | 1446.04 | 35 | 8.32 | 3147 | 6 | 6 |
7 | 561.28 | 35 | 9.51 | 1858 | 6 | 6 |
8 | 112.48 | 35 | 10.32 | 1119 | 6 | 6 |
9 | 0.08 | 181 | 10.65 | 802 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 41 | 10.66 | 865 | 7 | 7 |
2 | 1007.88 | 70 | 8.74 | 2424 | 6 | 6 |
3 | 650.92 | 35 | 9.32 | 1923 | 6 | 6 |
4 | 115.80 | 35 | 10.34 | 1072 | 6 | 6 |
5 | 0.20 | 181 | 10.62 | 786 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.20 | 41 | 10.66 | 884 | 7 | 7 |
2 | 1008.04 | 70 | 8.78 | 2424 | 6 | 6 |
3 | 652.00 | 35 | 9.39 | 1966 | 6 | 6 |
4 | 117.32 | 35 | 10.29 | 1091 | 6 | 6 |
5 | 0.08 | 181 | 10.66 | 751 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.60 | 41 | 10.66 | 884 | 7 | 7 |
2 | 1008.00 | 97 | 8.86 | 2396 | 7 | 6 |
3 | 114.48 | 35 | 10.43 | 1046 | 6 | 6 |
4 | 0.08 | 180 | 10.69 | 742 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.80 | 42 | 10.60 | 923 | 7 | 7 |
2 | 959.24 | -1 | 10.60 | 923 | 7 | 7 |
3 | 1154.76 | 14 | 8.54 | 2730 | 6 | 6 |
4 | 1953.88 | 20 | 7.66 | 3843 | 6 | 6 |
5 | 1952.12 | 96 | 7.65 | 3823 | 6 | 6 |
6 | 1277.36 | 35 | 8.65 | 2870 | 6 | 6 |
7 | 913.96 | 35 | 9.09 | 2381 | 6 | 6 |
8 | 178.16 | 35 | 10.24 | 1224 | 6 | 6 |
9 | 0.08 | 181 | 10.67 | 783 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 40 | 10.73 | 884 | 7 | 7 |
2 | 1011.68 | 97 | 8.82 | 2417 | 6 | 6 |
3 | 119.80 | 35 | 10.37 | 1071 | 6 | 6 |
4 | 24.84 | 35 | 10.60 | 862 | 6 | 7 |
5 | 0.12 | 181 | 10.69 | 738 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 40 | 10.73 | 903 | 7 | 7 |
2 | 1006.48 | 97 | 8.90 | 2388 | 7 | 6 |
3 | 113.76 | 35 | 10.40 | 1064 | 6 | 6 |
4 | 0.16 | 181 | 10.69 | 758 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 42 | 10.73 | 865 | 7 | 7 |
2 | 954.76 | -1 | 10.73 | 865 | 7 | 7 |
3 | 1145.32 | 75 | 8.67 | 2655 | 6 | 6 |
4 | 1149.64 | 31 | 8.79 | 2628 | 6 | 6 |
5 | 995.20 | 35 | 9.03 | 2462 | 6 | 6 |
6 | 446.64 | 35 | 9.77 | 1650 | 6 | 6 |
7 | 56.76 | 35 | 10.54 | 937 | 6 | 6 |
8 | 0.00 | 181 | 10.73 | 715 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.12 | 35 | 10.60 | 865 | 7 | 7 |
2 | 1038.88 | 4 | 8.94 | 2576 | 6 | 6 |
3 | 1072.64 | 2 | 8.94 | 2653 | 6 | 6 |
4 | 1043.88 | 1 | 8.69 | 2692 | 6 | 6 |
5 | 1184.36 | 11 | 8.59 | 2753 | 6 | 6 |
6 | 1991.28 | 75 | 7.57 | 3866 | 6 | 6 |
7 | 1985.96 | 30 | 7.50 | 3782 | 6 | 6 |
8 | 1495.36 | 35 | 8.24 | 3209 | 6 | 6 |
9 | 1139.52 | 35 | 8.75 | 2702 | 6 | 6 |
10 | 260.72 | 35 | 10.13 | 1303 | 6 | 6 |
11 | 61.00 | 35 | 10.57 | 917 | 6 | 6 |
12 | 0.12 | 181 | 10.73 | 716 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 38 | 10.73 | 807 | 7 | 7 |
2 | 1014.88 | 4 | 8.94 | 2576 | 6 | 6 |
3 | 1148.16 | 75 | 8.55 | 2592 | 6 | 6 |
4 | 1151.64 | 31 | 8.50 | 2594 | 6 | 6 |
5 | 984.48 | 34 | 8.84 | 2425 | 6 | 6 |
6 | 478.40 | 34 | 9.64 | 1676 | 6 | 6 |
7 | 66.80 | 34 | 10.48 | 948 | 6 | 6 |
8 | 0.08 | 181 | 10.68 | 715 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.56 | 36 | 11.11 | 807 | 7 | 7 |
2 | 1048.68 | 1 | 9.64 | 2826 | 6 | 6 |
3 | 1030.68 | 1 | 9.77 | 2769 | 6 | 6 |
4 | 1181.96 | 75 | 8.86 | 2647 | 6 | 6 |
5 | 1185.48 | 30 | 8.70 | 2633 | 6 | 6 |
6 | 872.96 | 35 | 9.19 | 2227 | 6 | 6 |
7 | 344.80 | 35 | 9.91 | 1425 | 6 | 6 |
8 | 71.68 | 35 | 10.51 | 908 | 6 | 6 |
9 | 0.16 | 180 | 10.70 | 703 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.80 | 34 | 11.75 | 846 | 7 | 7 |
2 | 1072.60 | 2 | 10.79 | 2884 | 6 | 6 |
3 | 1038.40 | 1 | 10.60 | 2826 | 6 | 6 |
4 | 1169.40 | 11 | 9.37 | 2707 | 6 | 6 |
5 | 1293.64 | 75 | 8.80 | 2780 | 6 | 6 |
6 | 1293.52 | 30 | 8.88 | 2771 | 6 | 6 |
7 | 783.24 | 36 | 9.81 | 2098 | 6 | 6 |
8 | 228.92 | 36 | 10.73 | 1220 | 6 | 7 |
9 | 1.96 | 36 | 11.24 | 774 | 6 | 7 |
10 | 0.08 | 180 | 11.07 | 676 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 32 | 12.31 | 826 | 7 | 7 |
2 | 1084.84 | 2 | 10.79 | 2826 | 6 | 6 |
3 | 1032.88 | 1 | 10.60 | 2788 | 6 | 6 |
4 | 1158.28 | 12 | 10.54 | 2795 | 6 | 6 |
5 | 1905.52 | 75 | 9.17 | 3748 | 6 | 6 |
6 | 1897.16 | 30 | 9.00 | 3710 | 6 | 6 |
7 | 998.48 | 36 | 10.15 | 2463 | 6 | 6 |
8 | 263.16 | 36 | 11.20 | 1292 | 6 | 7 |
9 | 46.88 | 36 | 11.71 | 871 | 6 | 7 |
10 | 0.00 | 181 | 11.61 | 711 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.44 | 33 | 12.70 | 807 | 7 | 7 |
2 | 1026.96 | 1 | 10.86 | 2923 | 6 | 6 |
3 | 1157.68 | 11 | 7.38 | 2480 | 6 | 6 |
4 | 1289.68 | 75 | 7.72 | 2687 | 6 | 6 |
5 | 1291.40 | 31 | 8.53 | 2733 | 6 | 6 |
6 | 1132.28 | 36 | 9.36 | 2595 | 6 | 6 |
7 | 423.12 | 36 | 10.98 | 1568 | 6 | 7 |
8 | 51.92 | 36 | 12.15 | 882 | 6 | 7 |
9 | 0.12 | 181 | 11.96 | 672 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 32 | 13.14 | 826 | 7 | 7 |
2 | 1154.16 | 11 | 8.65 | 2684 | 6 | 6 |
3 | 1281.88 | 75 | 8.60 | 2733 | 6 | 6 |
4 | 1281.48 | 31 | 8.77 | 2728 | 6 | 6 |
5 | 786.84 | 36 | 10.90 | 2154 | 6 | 6 |
6 | 228.80 | 37 | 12.03 | 1239 | 6 | 8 |
7 | 0.16 | 181 | 12.36 | 678 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.40 | 31 | 13.34 | 826 | 7 | 7 |
2 | 1042.80 | 1 | 11.69 | 3096 | 6 | 6 |
3 | 1174.84 | 12 | 9.50 | 2676 | 6 | 6 |
4 | 1292.24 | 75 | 9.07 | 2728 | 6 | 6 |
5 | 1290.76 | 30 | 9.22 | 2746 | 6 | 6 |
6 | 618.32 | 36 | 11.69 | 1900 | 6 | 7 |
7 | 112.44 | 36 | 12.86 | 976 | 6 | 7 |
8 | 0.12 | 181 | 12.73 | 681 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.68 | 30 | 13.53 | 826 | 7 | 7 |
2 | 1041.32 | 1 | 11.24 | 3134 | 6 | 6 |
3 | 1168.24 | 12 | 11.01 | 2822 | 6 | 6 |
4 | 1897.76 | 70 | 9.43 | 3750 | 6 | 6 |
5 | 1890.36 | 30 | 9.29 | 3732 | 6 | 6 |
6 | 974.52 | 36 | 11.54 | 2456 | 6 | 6 |
7 | 206.32 | 36 | 12.82 | 1167 | 6 | 8 |
8 | 13.08 | 36 | 13.16 | 815 | 6 | 8 |
9 | 0.08 | 181 | 12.81 | 694 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.68 | 30 | 13.78 | 884 | 7 | 7 |
2 | 1182.92 | 11 | 7.99 | 2718 | 6 | 6 |
3 | 1303.44 | 70 | 8.77 | 2800 | 6 | 6 |
4 | 1303.64 | 31 | 9.18 | 2808 | 6 | 6 |
5 | 973.40 | 36 | 11.09 | 2435 | 6 | 6 |
6 | 228.52 | 36 | 12.91 | 1226 | 6 | 8 |
7 | 0.00 | 180 | 13.09 | 698 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.52 | 30 | 13.97 | 846 | 7 | 7 |
2 | 1164.80 | 11 | 7.65 | 2653 | 6 | 6 |
3 | 1297.52 | 70 | 8.44 | 2763 | 6 | 6 |
4 | 1299.16 | 31 | 9.07 | 2791 | 6 | 6 |
5 | 1132.16 | 37 | 10.34 | 2653 | 6 | 6 |
6 | 203.32 | 37 | 13.28 | 1148 | 6 | 8 |
7 | 15.52 | 37 | 13.79 | 798 | 6 | 9 |
8 | 0.00 | 181 | 13.27 | 699 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 30 | 14.17 | 865 | 7 | 7 |
2 | 1157.64 | 12 | 9.18 | 2741 | 6 | 6 |
3 | 1293.04 | 70 | 9.44 | 2830 | 6 | 6 |
4 | 1293.36 | 31 | 9.51 | 2820 | 6 | 6 |
5 | 779.40 | 36 | 12.19 | 2164 | 6 | 7 |
6 | 94.68 | 36 | 13.76 | 962 | 6 | 8 |
7 | 0.04 | 181 | 13.57 | 702 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.12 | 30 | 14.10 | 865 | 7 | 7 |
2 | 1147.68 | 12 | 11.11 | 2884 | 6 | 6 |
3 | 1884.00 | 70 | 9.84 | 3744 | 6 | 6 |
4 | 1875.28 | 31 | 9.90 | 3765 | 6 | 6 |
5 | 925.44 | 36 | 12.44 | 2386 | 6 | 7 |
6 | 142.44 | 36 | 13.78 | 1069 | 6 | 9 |
7 | 0.16 | 181 | 13.65 | 723 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 30 | 14.17 | 903 | 7 | 7 |
2 | 1159.16 | 11 | 7.55 | 2565 | 6 | 6 |
3 | 1292.92 | 70 | 8.75 | 2786 | 6 | 6 |
4 | 1294.20 | 31 | 9.21 | 2784 | 6 | 6 |
5 | 1128.80 | 36 | 10.80 | 2686 | 6 | 6 |
6 | 206.48 | 37 | 13.53 | 1195 | 6 | 8 |
7 | 0.12 | 181 | 13.65 | 734 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.20 | 30 | 14.10 | 865 | 7 | 7 |
2 | 1157.32 | 11 | 8.21 | 2715 | 6 | 6 |
3 | 1281.64 | 70 | 9.38 | 2830 | 6 | 6 |
4 | 1283.64 | 41 | 9.14 | 2766 | 6 | 6 |
5 | 1276.24 | 31 | 9.56 | 2793 | 6 | 6 |
6 | 261.72 | 36 | 13.39 | 1330 | 6 | 10 |
7 | 0.00 | 181 | 13.67 | 741 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.40 | 30 | 14.23 | 846 | 7 | 7 |
2 | 1154.28 | 12 | 9.20 | 2857 | 6 | 6 |
3 | 1278.44 | 70 | 10.21 | 2792 | 6 | 6 |
4 | 1280.04 | 41 | 9.57 | 2724 | 6 | 6 |
5 | 1272.12 | 30 | 9.87 | 2734 | 6 | 6 |
6 | 92.36 | 36 | 13.84 | 1002 | 6 | 8 |
7 | 0.04 | 181 | 13.86 | 705 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.92 | 30 | 14.17 | 826 | 7 | 7 |
2 | 1135.44 | 12 | 11.23 | 2888 | 6 | 6 |
3 | 1882.24 | 70 | 10.00 | 3743 | 6 | 6 |
4 | 1877.88 | 41 | 9.77 | 3687 | 6 | 6 |
5 | 1868.20 | 31 | 9.86 | 3653 | 6 | 6 |
6 | 202.64 | 36 | 13.72 | 1182 | 6 | 9 |
7 | 0.04 | 181 | 13.89 | 697 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 30 | 14.23 | 807 | 7 | 7 |
2 | 1167.00 | 11 | 7.62 | 2591 | 6 | 6 |
3 | 1307.24 | 70 | 9.25 | 2811 | 6 | 6 |
4 | 1309.44 | 41 | 9.10 | 2763 | 6 | 6 |
5 | 1302.24 | 31 | 9.37 | 2782 | 6 | 6 |
6 | 302.40 | 36 | 13.35 | 1392 | 6 | 10 |
7 | 38.84 | 36 | 14.00 | 873 | 6 | 10 |
8 | 0.00 | 180 | 13.86 | 711 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.36 | 30 | 14.17 | 865 | 7 | 7 |
2 | 1147.64 | 11 | 8.48 | 2661 | 6 | 6 |
3 | 1286.28 | 70 | 9.68 | 2793 | 6 | 6 |
4 | 1289.16 | 41 | 9.36 | 2707 | 6 | 6 |
5 | 1282.48 | 31 | 9.61 | 2732 | 6 | 6 |
6 | 124.08 | 37 | 13.77 | 1070 | 6 | 8 |
7 | 0.00 | 181 | 13.96 | 700 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.72 | 30 | 14.23 | 807 | 7 | 7 |
2 | 1144.68 | 12 | 9.33 | 2761 | 6 | 6 |
3 | 1275.52 | 70 | 10.35 | 2814 | 6 | 6 |
4 | 1276.76 | 41 | 9.65 | 2719 | 6 | 6 |
5 | 1268.48 | 31 | 9.86 | 2758 | 6 | 6 |
6 | 92.12 | 36 | 13.90 | 1000 | 6 | 8 |
7 | 0.04 | 181 | 14.01 | 699 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.12 | 30 | 14.23 | 846 | 7 | 7 |
2 | 1158.76 | 12 | 11.15 | 2918 | 6 | 6 |
3 | 1887.24 | 70 | 9.99 | 3748 | 6 | 6 |
4 | 1882.84 | 41 | 9.80 | 3645 | 6 | 6 |
5 | 1873.32 | 31 | 9.96 | 3660 | 6 | 6 |
6 | 175.60 | 36 | 13.77 | 1128 | 6 | 9 |
7 | 0.16 | 181 | 14.03 | 681 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.20 | 30 | 14.29 | 788 | 7 | 7 |
2 | 1135.40 | 11 | 8.09 | 2530 | 6 | 6 |
3 | 1277.48 | 70 | 9.38 | 2774 | 6 | 6 |
4 | 1280.00 | 41 | 9.30 | 2734 | 6 | 6 |
5 | 1272.96 | 31 | 9.56 | 2750 | 6 | 6 |
6 | 244.92 | 36 | 13.56 | 1261 | 6 | 10 |
7 | 0.12 | 181 | 13.98 | 698 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.32 | 30 | 14.17 | 865 | 7 | 7 |
2 | 1137.60 | 70 | 12.08 | 801 | 6 | 6 |
3 | 1145.20 | 41 | 8.57 | 2428 | 6 | 6 |
4 | 1150.24 | 31 | 9.86 | 2557 | 6 | 6 |
5 | 1050.16 | 36 | 12.01 | 2520 | 6 | 6 |
6 | 712.64 | 36 | 12.89 | 1991 | 6 | 8 |
7 | 55.32 | 37 | 13.99 | 884 | 6 | 9 |
8 | 0.08 | 181 | 14.05 | 681 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.08 | 30 | 14.23 | 826 | 7 | 7 |
2 | 1142.12 | 70 | 12.34 | 832 | 6 | 6 |
3 | 1149.08 | 41 | 9.05 | 2452 | 6 | 6 |
4 | 1153.36 | 31 | 10.05 | 2570 | 6 | 6 |
5 | 1033.08 | 37 | 12.15 | 2504 | 6 | 6 |
6 | 495.72 | 37 | 13.28 | 1648 | 6 | 9 |
7 | 46.76 | 36 | 14.05 | 855 | 6 | 9 |
8 | 0.00 | 181 | 14.09 | 681 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.36 | 30 | 14.17 | 865 | 7 | 7 |
2 | 1144.32 | 15 | 11.35 | 2797 | 6 | 6 |
3 | 1807.72 | 70 | 10.21 | 3616 | 6 | 6 |
4 | 1803.08 | 41 | 9.97 | 3548 | 6 | 6 |
5 | 1793.16 | 31 | 10.17 | 3566 | 6 | 6 |
6 | 208.36 | 37 | 13.73 | 1171 | 6 | 10 |
7 | 0.08 | 181 | 14.02 | 713 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.60 | 30 | 14.23 | 826 | 7 | 7 |
2 | 1161.64 | 70 | 11.39 | 882 | 6 | 6 |
3 | 1169.52 | 41 | 7.61 | 2445 | 6 | 6 |
4 | 1175.64 | 31 | 9.79 | 2602 | 6 | 6 |
5 | 1094.52 | 36 | 11.88 | 2597 | 6 | 6 |
6 | 750.56 | 37 | 12.71 | 2073 | 6 | 8 |
7 | 76.44 | 36 | 13.98 | 952 | 6 | 8 |
8 | 0.04 | 180 | 14.07 | 703 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.32 | 30 | 14.17 | 788 | 7 | 7 |
2 | 1156.40 | 70 | 11.81 | 843 | 6 | 6 |
3 | 1165.20 | 41 | 8.24 | 2446 | 6 | 6 |
4 | 1171.28 | 31 | 9.91 | 2609 | 6 | 6 |
5 | 1082.16 | 36 | 11.95 | 2599 | 6 | 6 |
6 | 734.92 | 36 | 12.81 | 2047 | 6 | 8 |
7 | 65.36 | 36 | 13.95 | 910 | 6 | 8 |
8 | 0.08 | 180 | 14.09 | 717 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.16 | 30 | 14.29 | 769 | 7 | 7 |
2 | 1137.76 | 70 | 12.10 | 826 | 6 | 6 |
3 | 1145.52 | 41 | 8.88 | 2445 | 6 | 6 |
4 | 1150.80 | 31 | 10.13 | 2542 | 6 | 6 |
5 | 1036.68 | 36 | 12.21 | 2527 | 6 | 6 |
6 | 526.16 | 36 | 13.19 | 1698 | 6 | 9 |
7 | 59.40 | 36 | 13.96 | 886 | 6 | 9 |
8 | 0.04 | 181 | 14.13 | 677 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 30 | 14.17 | 826 | 7 | 7 |
2 | 1133.16 | 15 | 11.15 | 2839 | 6 | 6 |
3 | 1807.48 | 70 | 9.93 | 3642 | 6 | 6 |
4 | 1802.56 | 41 | 9.84 | 3554 | 6 | 6 |
5 | 1792.36 | 31 | 9.99 | 3553 | 6 | 6 |
6 | 124.52 | 37 | 13.86 | 999 | 6 | 8 |
7 | 0.04 | 180 | 14.12 | 692 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 30 | 14.17 | 807 | 7 | 7 |
2 | 1145.00 | 70 | 11.04 | 801 | 6 | 6 |
3 | 1152.24 | 41 | 6.63 | 2355 | 6 | 6 |
4 | 1157.96 | 30 | 9.50 | 2573 | 6 | 6 |
5 | 1100.00 | 36 | 11.69 | 2621 | 6 | 6 |
6 | 783.64 | 36 | 12.65 | 2138 | 6 | 7 |
7 | 101.20 | 36 | 13.92 | 958 | 6 | 8 |
8 | 0.12 | 181 | 14.12 | 692 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 30 | 14.17 | 807 | 7 | 7 |
2 | 1178.64 | 70 | 11.41 | 793 | 6 | 6 |
3 | 1187.36 | 41 | 7.04 | 2415 | 6 | 6 |
4 | 1193.68 | 31 | 9.68 | 2610 | 6 | 6 |
5 | 1118.56 | 36 | 11.80 | 2623 | 6 | 6 |
6 | 955.76 | 37 | 12.27 | 2331 | 6 | 7 |
7 | 74.96 | 36 | 13.97 | 911 | 6 | 8 |
8 | 0.08 | 181 | 14.14 | 684 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.56 | 30 | 14.17 | 846 | 7 | 7 |
2 | 1160.68 | 70 | 11.97 | 805 | 6 | 6 |
3 | 1168.32 | 41 | 8.05 | 2480 | 6 | 6 |
4 | 1173.64 | 31 | 10.02 | 2611 | 6 | 6 |
5 | 1086.88 | 37 | 12.07 | 2550 | 6 | 6 |
6 | 559.32 | 36 | 13.17 | 1720 | 6 | 8 |
7 | 77.52 | 36 | 13.97 | 897 | 6 | 9 |
8 | 0.04 | 181 | 14.14 | 662 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 30 | 14.17 | 788 | 7 | 7 |
2 | 1135.36 | 20 | 11.05 | 2706 | 6 | 6 |
3 | 1681.88 | 70 | 9.96 | 3396 | 6 | 6 |
4 | 1677.48 | 41 | 9.73 | 3386 | 6 | 6 |
5 | 1667.88 | 31 | 9.91 | 3367 | 6 | 6 |
6 | 128.60 | 36 | 13.87 | 980 | 6 | 9 |
7 | 0.04 | 181 | 14.14 | 663 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 30 | 14.10 | 788 | 7 | 7 |
2 | 1154.48 | 100 | 5.88 | 2367 | 6 | 6 |
3 | 1164.64 | 31 | 9.47 | 2663 | 6 | 6 |
4 | 1065.00 | 37 | 11.64 | 2520 | 6 | 6 |
5 | 547.20 | 37 | 13.12 | 1686 | 6 | 9 |
6 | 60.36 | 36 | 13.98 | 866 | 6 | 9 |
7 | 0.00 | 181 | 14.15 | 640 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.00 | 30 | 14.17 | 769 | 7 | 7 |
2 | 1144.36 | 100 | 7.42 | 2426 | 6 | 6 |
3 | 1148.60 | 31 | 9.92 | 2627 | 6 | 6 |
4 | 812.08 | 37 | 12.56 | 2113 | 6 | 7 |
5 | 104.88 | 37 | 13.91 | 907 | 6 | 9 |
6 | 0.08 | 181 | 14.17 | 648 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.32 | 30 | 14.17 | 769 | 7 | 7 |
2 | 1137.04 | 100 | 8.59 | 2511 | 6 | 6 |
3 | 1140.64 | 31 | 10.17 | 2606 | 6 | 6 |
4 | 445.08 | 36 | 13.37 | 1488 | 6 | 9 |
5 | 41.84 | 37 | 14.04 | 740 | 6 | 9 |
6 | 0.04 | 180 | 14.16 | 614 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.16 | 30 | 14.23 | 750 | 7 | 7 |
2 | 1137.56 | 20 | 11.01 | 2699 | 6 | 6 |
3 | 1678.72 | 100 | 9.90 | 3363 | 6 | 6 |
4 | 1664.60 | 31 | 10.07 | 3396 | 6 | 6 |
5 | 157.36 | 36 | 13.81 | 1018 | 6 | 9 |
6 | 0.00 | 180 | 14.14 | 648 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.84 | 30 | 14.23 | 750 | 7 | 7 |
2 | 1139.84 | 100 | 5.80 | 2321 | 6 | 6 |
3 | 1151.08 | 30 | 9.75 | 2639 | 6 | 6 |
4 | 1066.64 | 36 | 11.81 | 2575 | 6 | 6 |
5 | 551.52 | 36 | 13.13 | 1702 | 6 | 9 |
6 | 68.96 | 36 | 13.99 | 827 | 6 | 9 |
7 | 0.12 | 181 | 14.14 | 642 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.88 | 30 | 14.10 | 788 | 7 | 7 |
2 | 1155.68 | 100 | 7.39 | 2480 | 6 | 6 |
3 | 1161.80 | 31 | 10.10 | 2645 | 6 | 6 |
4 | 994.84 | 36 | 12.24 | 2443 | 6 | 6 |
5 | 99.24 | 36 | 13.94 | 913 | 6 | 8 |
6 | 0.00 | 181 | 14.17 | 619 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.72 | 30 | 14.17 | 788 | 7 | 7 |
2 | 1153.80 | 100 | 8.80 | 2491 | 6 | 6 |
3 | 1154.76 | 31 | 10.36 | 2551 | 6 | 6 |
4 | 430.52 | 37 | 13.32 | 1516 | 6 | 9 |
5 | 36.88 | 37 | 14.04 | 740 | 6 | 9 |
6 | 0.00 | 180 | 14.14 | 623 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 30 | 13.91 | 846 | 7 | 7 |
2 | 1146.00 | 22 | 11.04 | 2798 | 6 | 6 |
3 | 1637.96 | 100 | 10.03 | 3353 | 6 | 6 |
4 | 1624.44 | 31 | 10.19 | 3353 | 6 | 6 |
5 | 131.36 | 37 | 13.82 | 1024 | 6 | 9 |
6 | 0.16 | 181 | 14.14 | 659 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.92 | 30 | 14.10 | 788 | 7 | 7 |
2 | 1145.64 | 100 | 5.97 | 2336 | 6 | 6 |
3 | 1156.24 | 41 | 9.86 | 2593 | 6 | 6 |
4 | 1038.96 | 37 | 11.97 | 2521 | 6 | 6 |
5 | 296.44 | 36 | 13.59 | 1282 | 6 | 10 |
6 | 15.12 | 36 | 14.06 | 771 | 6 | 9 |
7 | 0.04 | 181 | 14.07 | 682 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 30 | 14.04 | 807 | 7 | 7 |
2 | 1147.92 | 100 | 7.52 | 2488 | 6 | 6 |
3 | 1152.44 | 41 | 10.09 | 2662 | 6 | 6 |
4 | 623.80 | 36 | 13.01 | 1870 | 6 | 8 |
5 | 97.68 | 37 | 13.95 | 912 | 6 | 9 |
6 | 0.08 | 180 | 14.13 | 684 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.88 | 30 | 14.10 | 788 | 7 | 7 |
2 | 1157.64 | 100 | 8.52 | 2479 | 6 | 6 |
3 | 1157.32 | 41 | 10.31 | 2589 | 6 | 6 |
4 | 249.56 | 36 | 13.65 | 1261 | 6 | 8 |
5 | 0.12 | 181 | 14.16 | 647 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.56 | 30 | 14.23 | 750 | 7 | 7 |
2 | 1150.52 | 23 | 10.99 | 2760 | 6 | 6 |
3 | 1614.16 | 100 | 10.16 | 3272 | 6 | 6 |
4 | 1599.84 | 41 | 10.24 | 3250 | 6 | 6 |
5 | 91.12 | 36 | 13.93 | 911 | 6 | 8 |
6 | 0.12 | 181 | 14.14 | 666 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.32 | 30 | 14.17 | 750 | 7 | 7 |
2 | 1143.04 | 95 | 6.09 | 2344 | 6 | 6 |
3 | 1152.56 | 51 | 9.81 | 2619 | 6 | 6 |
4 | 990.12 | 37 | 12.13 | 2447 | 6 | 6 |
5 | 221.36 | 37 | 13.67 | 1144 | 6 | 9 |
6 | 0.08 | 181 | 14.09 | 688 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.32 | 30 | 14.17 | 769 | 7 | 7 |
2 | 1158.92 | 95 | 7.11 | 2442 | 6 | 6 |
3 | 1165.68 | 51 | 10.13 | 2618 | 6 | 6 |
4 | 650.20 | 36 | 12.99 | 1897 | 6 | 8 |
5 | 105.24 | 37 | 13.90 | 898 | 6 | 9 |
6 | 0.08 | 181 | 14.13 | 646 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.88 | 30 | 14.17 | 750 | 7 | 7 |
2 | 1153.80 | 95 | 8.05 | 2495 | 6 | 6 |
3 | 1156.76 | 51 | 10.24 | 2615 | 6 | 6 |
4 | 401.16 | 36 | 13.39 | 1489 | 6 | 9 |
5 | 37.24 | 37 | 13.99 | 820 | 6 | 9 |
6 | 0.00 | 181 | 14.11 | 658 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.76 | 30 | 14.23 | 750 | 7 | 7 |
2 | 1150.68 | 23 | 10.87 | 2717 | 6 | 6 |
3 | 1618.56 | 96 | 10.11 | 3274 | 6 | 6 |
4 | 1606.04 | 51 | 10.18 | 3272 | 6 | 6 |
5 | 83.76 | 36 | 13.94 | 857 | 6 | 9 |
6 | 0.04 | 181 | 14.13 | 637 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.92 | 30 | 14.10 | 769 | 7 | 7 |
2 | 1145.96 | 95 | 5.75 | 2311 | 6 | 6 |
3 | 1157.00 | 51 | 9.79 | 2598 | 6 | 6 |
4 | 1013.52 | 37 | 12.16 | 2457 | 6 | 6 |
5 | 277.64 | 37 | 13.57 | 1225 | 6 | 10 |
6 | 0.20 | 181 | 14.12 | 639 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 30 | 14.10 | 788 | 7 | 7 |
2 | 1146.16 | 95 | 6.68 | 2320 | 6 | 6 |
3 | 1153.56 | 51 | 10.00 | 2620 | 6 | 6 |
4 | 799.36 | 36 | 12.76 | 2124 | 6 | 7 |
5 | 94.80 | 36 | 13.91 | 899 | 6 | 8 |
6 | 0.00 | 181 | 14.11 | 649 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.08 | 30 | 13.97 | 826 | 7 | 7 |
2 | 1160.96 | 95 | 7.59 | 2444 | 6 | 6 |
3 | 1165.00 | 50 | 10.24 | 2610 | 6 | 6 |
4 | 435.60 | 36 | 13.34 | 1507 | 6 | 9 |
5 | 44.36 | 36 | 14.02 | 742 | 6 | 8 |
6 | 0.12 | 181 | 14.11 | 628 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.88 | 30 | 14.10 | 750 | 7 | 7 |
2 | 1148.88 | 23 | 10.84 | 2696 | 6 | 6 |
3 | 1607.24 | 96 | 10.00 | 3259 | 6 | 6 |
4 | 1593.28 | 51 | 10.22 | 3206 | 6 | 6 |
5 | 66.36 | 37 | 13.94 | 833 | 6 | 8 |
6 | 0.04 | 181 | 14.10 | 617 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 30 | 14.17 | 750 | 7 | 7 |
2 | 1157.84 | 95 | 5.53 | 2311 | 6 | 6 |
3 | 1169.64 | 51 | 9.81 | 2579 | 6 | 6 |
4 | 1041.16 | 36 | 12.25 | 2457 | 6 | 6 |
5 | 319.56 | 36 | 13.55 | 1245 | 6 | 9 |
6 | 23.04 | 36 | 14.09 | 680 | 6 | 9 |
7 | 0.08 | 181 | 14.14 | 603 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.24 | 30 | 14.17 | 750 | 7 | 7 |
2 | 1148.00 | 95 | 6.36 | 2318 | 6 | 6 |
3 | 1158.00 | 51 | 10.03 | 2617 | 6 | 6 |
4 | 831.56 | 37 | 12.71 | 2145 | 6 | 7 |
5 | 111.60 | 37 | 13.88 | 895 | 6 | 8 |
6 | 0.00 | 181 | 14.13 | 617 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.64 | 30 | 14.04 | 769 | 7 | 7 |
2 | 1161.52 | 95 | 7.46 | 2412 | 6 | 6 |
3 | 1166.64 | 51 | 10.27 | 2596 | 6 | 6 |
4 | 618.28 | 37 | 13.07 | 1773 | 6 | 8 |
5 | 42.04 | 37 | 14.03 | 723 | 6 | 8 |
6 | 0.08 | 181 | 14.16 | 608 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.88 | 30 | 14.04 | 750 | 7 | 7 |
2 | 1154.12 | 23 | 10.94 | 2662 | 6 | 6 |
3 | 1625.72 | 96 | 9.99 | 3284 | 6 | 6 |
4 | 1613.60 | 51 | 10.20 | 3280 | 6 | 6 |
5 | 78.84 | 36 | 13.94 | 806 | 6 | 8 |
6 | 0.04 | 181 | 14.10 | 619 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 30 | 14.10 | 711 | 7 | 7 |
2 | 1147.60 | 95 | 5.78 | 2268 | 6 | 6 |
3 | 1156.64 | 51 | 9.91 | 2564 | 6 | 6 |
4 | 999.28 | 37 | 12.33 | 2379 | 6 | 6 |
5 | 229.72 | 37 | 13.67 | 1072 | 6 | 9 |
6 | 0.04 | 181 | 14.14 | 588 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.52 | 30 | 14.04 | 769 | 7 | 7 |
2 | 1159.24 | 95 | 6.03 | 2309 | 6 | 6 |
3 | 1169.80 | 51 | 10.06 | 2564 | 6 | 6 |
4 | 1018.88 | 36 | 12.42 | 2422 | 6 | 6 |
5 | 143.08 | 37 | 13.83 | 923 | 6 | 8 |
6 | 0.08 | 181 | 14.17 | 588 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.48 | 30 | 14.10 | 750 | 7 | 7 |
2 | 1182.44 | 91 | 7.04 | 2380 | 6 | 6 |
3 | 1188.52 | 51 | 10.24 | 2589 | 6 | 6 |
4 | 821.76 | 36 | 12.90 | 2073 | 6 | 8 |
5 | 84.16 | 37 | 13.99 | 799 | 6 | 9 |
6 | 0.04 | 181 | 14.15 | 584 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.48 | 30 | 13.97 | 788 | 7 | 7 |
2 | 1151.80 | 23 | 10.94 | 2657 | 6 | 6 |
3 | 1614.88 | 91 | 10.07 | 3239 | 6 | 6 |
4 | 1603.00 | 51 | 10.28 | 3238 | 6 | 6 |
5 | 74.20 | 36 | 13.94 | 801 | 6 | 8 |
6 | -0.04 | 180 | 14.12 | 595 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.00 | 30 | 14.17 | 750 | 7 | 7 |
2 | 1145.36 | 91 | 5.61 | 2262 | 6 | 6 |
3 | 1155.76 | 51 | 9.93 | 2536 | 6 | 6 |
4 | 1027.76 | 36 | 12.42 | 2400 | 6 | 6 |
5 | 474.52 | 36 | 13.30 | 1503 | 6 | 10 |
6 | 42.08 | 36 | 14.02 | 733 | 6 | 9 |
7 | 0.04 | 180 | 14.14 | 596 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 30 | 14.04 | 750 | 7 | 7 |
2 | 1153.00 | 91 | 5.81 | 2298 | 6 | 6 |
3 | 1163.92 | 51 | 9.99 | 2572 | 6 | 6 |
4 | 1019.32 | 36 | 12.43 | 2414 | 6 | 6 |
5 | 261.00 | 37 | 13.65 | 1117 | 6 | 10 |
6 | 0.08 | 181 | 14.14 | 593 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.28 | 30 | 14.17 | 750 | 7 | 7 |
2 | 1152.96 | 91 | 7.02 | 2349 | 6 | 6 |
3 | 1160.72 | 50 | 10.32 | 2541 | 6 | 6 |
4 | 621.20 | 36 | 13.14 | 1741 | 6 | 8 |
5 | 89.20 | 36 | 13.96 | 793 | 6 | 9 |
6 | 0.04 | 181 | 14.14 | 594 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.32 | 30 | 14.17 | 730 | 7 | 7 |
2 | 1154.88 | 23 | 11.01 | 2602 | 6 | 6 |
3 | 1610.36 | 91 | 10.02 | 3234 | 6 | 6 |
4 | 1598.04 | 51 | 10.32 | 3248 | 6 | 6 |
5 | 76.16 | 37 | 13.94 | 781 | 6 | 8 |
6 | 0.04 | 181 | 14.13 | 578 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.28 | 30 | 14.10 | 750 | 7 | 7 |
2 | 1155.12 | 91 | 5.30 | 2267 | 6 | 6 |
3 | 1165.64 | 51 | 9.89 | 2556 | 6 | 6 |
4 | 1045.32 | 36 | 12.43 | 2425 | 6 | 6 |
5 | 518.68 | 36 | 13.29 | 1591 | 6 | 9 |
6 | 47.52 | 37 | 13.98 | 734 | 6 | 9 |
7 | 0.00 | 181 | 14.13 | 602 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 30 | 13.91 | 788 | 7 | 7 |
2 | 1137.68 | 91 | 6.16 | 2287 | 6 | 6 |
3 | 1146.00 | 50 | 10.13 | 2522 | 6 | 6 |
4 | 995.28 | 36 | 12.53 | 2347 | 6 | 6 |
5 | 215.20 | 36 | 13.70 | 1022 | 6 | 9 |
6 | 0.08 | 181 | 14.12 | 604 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.60 | 30 | 14.04 | 730 | 7 | 7 |
2 | 1165.12 | 91 | 7.05 | 2325 | 6 | 6 |
3 | 1170.80 | 50 | 10.29 | 2552 | 6 | 6 |
4 | 485.80 | 36 | 13.33 | 1529 | 6 | 8 |
5 | 53.56 | 36 | 14.03 | 694 | 6 | 8 |
6 | 0.00 | 180 | 14.15 | 588 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 30 | 14.04 | 750 | 7 | 7 |
2 | 1143.44 | 23 | 11.01 | 2636 | 6 | 6 |
3 | 1599.88 | 91 | 10.07 | 3242 | 6 | 6 |
4 | 1587.44 | 50 | 10.31 | 3229 | 6 | 6 |
5 | 81.56 | 36 | 13.92 | 808 | 6 | 8 |
6 | 0.08 | 181 | 14.10 | 579 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.68 | 30 | 14.04 | 730 | 7 | 7 |
2 | 1159.76 | 91 | 5.47 | 2269 | 6 | 6 |
3 | 1171.56 | 50 | 9.92 | 2554 | 6 | 6 |
4 | 1047.04 | 36 | 12.42 | 2414 | 6 | 6 |
5 | 336.80 | 36 | 13.50 | 1242 | 6 | 9 |
6 | 28.08 | 36 | 14.05 | 668 | 6 | 8 |
7 | 0.08 | 181 | 14.13 | 589 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.88 | 30 | 14.17 | 730 | 7 | 7 |
2 | 1141.52 | 91 | 5.92 | 2232 | 6 | 6 |
3 | 1152.56 | 51 | 10.00 | 2541 | 6 | 6 |
4 | 1010.40 | 37 | 12.47 | 2341 | 6 | 6 |
5 | 132.40 | 37 | 13.84 | 871 | 6 | 8 |
6 | 0.36 | 180 | 14.14 | 595 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 30 | 14.04 | 750 | 7 | 6 |
2 | 1146.28 | 91 | 6.79 | 2345 | 6 | 6 |
3 | 1153.64 | 51 | 10.31 | 2514 | 6 | 6 |
4 | 808.12 | 37 | 12.88 | 2024 | 6 | 7 |
5 | 93.56 | 36 | 13.92 | 800 | 6 | 8 |
6 | 0.04 | 180 | 14.17 | 588 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.40 | 30 | 14.10 | 769 | 6 | 7 |
2 | 1142.08 | 23 | 11.10 | 2565 | 6 | 6 |
3 | 1591.68 | 91 | 10.07 | 3190 | 6 | 6 |
4 | 1579.84 | 51 | 10.34 | 3209 | 6 | 6 |
5 | 82.24 | 36 | 13.92 | 788 | 6 | 8 |
6 | 0.40 | 181 | 14.07 | 599 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 30 | 14.17 | 711 | 7 | 7 |
2 | 1158.64 | 91 | 5.18 | 2287 | 6 | 6 |
3 | 1171.52 | 51 | 9.97 | 2536 | 6 | 6 |
4 | 1062.96 | 36 | 12.50 | 2403 | 6 | 6 |
5 | 541.04 | 37 | 13.22 | 1572 | 6 | 9 |
6 | 26.32 | 36 | 14.09 | 678 | 6 | 8 |
7 | -0.08 | 181 | 14.15 | 595 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.80 | 30 | 14.04 | 730 | 7 | 6 |
2 | 1151.88 | 91 | 5.89 | 2274 | 6 | 6 |
3 | 1162.28 | 51 | 10.14 | 2534 | 6 | 6 |
4 | 1013.84 | 37 | 12.56 | 2327 | 6 | 6 |
5 | 258.36 | 36 | 13.66 | 1083 | 6 | 9 |
6 | 0.08 | 181 | 14.14 | 587 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 30 | 14.04 | 750 | 7 | 6 |
2 | 1167.08 | 91 | 6.83 | 2347 | 6 | 6 |
3 | 1173.48 | 51 | 10.36 | 2531 | 6 | 6 |
4 | 659.00 | 36 | 13.10 | 1750 | 6 | 7 |
5 | 116.08 | 36 | 13.88 | 824 | 6 | 8 |
6 | 0.04 | 181 | 14.13 | 601 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 30 | 14.04 | 711 | 7 | 7 |
2 | 1147.52 | 27 | 11.04 | 2599 | 6 | 6 |
3 | 1494.08 | 72 | 10.34 | 3079 | 6 | 6 |
4 | 1487.60 | 80 | 10.29 | 3025 | 6 | 7 |
5 | 30.52 | 37 | 13.97 | 699 | 6 | 9 |
6 | 0.04 | 181 | 14.02 | 613 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.28 | 30 | 14.10 | 711 | 7 | 7 |
2 | 1145.48 | 72 | 6.56 | 2249 | 6 | 6 |
3 | 1151.72 | 80 | 9.47 | 2438 | 6 | 6 |
4 | 607.96 | 37 | 13.07 | 1659 | 6 | 8 |
5 | 81.28 | 37 | 13.91 | 775 | 6 | 9 |
6 | 0.04 | 181 | 14.08 | 607 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.88 | 30 | 14.04 | 730 | 6 | 7 |
2 | 1141.16 | 72 | 6.87 | 2257 | 6 | 6 |
3 | 1147.28 | 80 | 9.44 | 2448 | 6 | 6 |
4 | 439.52 | 37 | 13.25 | 1426 | 6 | 9 |
5 | 42.44 | 37 | 13.99 | 689 | 6 | 9 |
6 | -0.04 | 181 | 14.11 | 580 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.04 | 30 | 14.10 | 730 | 7 | 7 |
2 | 1156.52 | 72 | 6.89 | 2340 | 6 | 6 |
3 | 1164.24 | 80 | 9.60 | 2460 | 6 | 6 |
4 | 447.80 | 37 | 13.27 | 1425 | 6 | 9 |
5 | 44.76 | 37 | 13.97 | 714 | 6 | 8 |
6 | 0.04 | 181 | 14.12 | 583 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.20 | 30 | 14.10 | 711 | 6 | 6 |
2 | 1137.40 | 27 | 11.08 | 2538 | 6 | 6 |
3 | 1492.92 | 72 | 10.25 | 3031 | 6 | 6 |
4 | 1486.04 | 80 | 10.11 | 3011 | 6 | 7 |
5 | 34.28 | 37 | 13.93 | 682 | 6 | 8 |
6 | 0.00 | 181 | 14.05 | 583 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 30 | 14.10 | 730 | 7 | 7 |
2 | 1157.52 | 72 | 6.42 | 2311 | 6 | 6 |
3 | 1165.52 | 80 | 8.95 | 2436 | 6 | 6 |
4 | 649.56 | 37 | 12.95 | 1729 | 6 | 8 |
5 | 108.76 | 37 | 13.85 | 804 | 6 | 9 |
6 | 0.08 | 181 | 14.05 | 599 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 30 | 14.04 | 730 | 6 | 7 |
2 | 1145.32 | 72 | 5.53 | 2250 | 6 | 6 |
3 | 1153.12 | 80 | 9.04 | 2406 | 6 | 6 |
4 | 993.28 | 37 | 12.47 | 2259 | 6 | 6 |
5 | 195.56 | 37 | 13.67 | 972 | 6 | 9 |
6 | 0.08 | 180 | 14.09 | 586 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.64 | 30 | 13.91 | 730 | 7 | 7 |
2 | 1153.60 | 49 | 6.53 | 2305 | 6 | 6 |
3 | 1167.76 | 80 | 10.39 | 2470 | 6 | 6 |
4 | 635.28 | 37 | 12.98 | 1703 | 6 | 8 |
5 | 88.92 | 36 | 13.89 | 796 | 6 | 9 |
6 | 0.08 | 181 | 14.06 | 584 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.60 | 30 | 14.04 | 730 | 7 | 7 |
2 | 1150.20 | 36 | 10.91 | 2505 | 6 | 6 |
3 | 1273.24 | 49 | 10.81 | 2691 | 6 | 6 |
4 | 1258.20 | 80 | 10.88 | 2650 | 6 | 7 |
5 | 14.32 | 37 | 13.94 | 671 | 6 | 9 |
6 | 0.16 | 181 | 14.01 | 590 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.24 | 30 | 13.97 | 730 | 7 | 7 |
2 | 1131.24 | 49 | 5.30 | 2181 | 6 | 6 |
3 | 1147.28 | 81 | 9.78 | 2398 | 6 | 6 |
4 | 987.40 | 36 | 12.34 | 2235 | 6 | 6 |
5 | 187.12 | 36 | 13.65 | 943 | 6 | 9 |
6 | 0.20 | 181 | 14.03 | 589 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.44 | 30 | 13.97 | 730 | 7 | 7 |
2 | 1165.28 | 49 | 7.03 | 2332 | 6 | 6 |
3 | 1175.76 | 80 | 9.98 | 2467 | 6 | 6 |
4 | 484.76 | 37 | 13.02 | 1499 | 6 | 8 |
5 | 57.16 | 37 | 13.89 | 726 | 6 | 8 |
6 | 0.12 | 180 | 14.02 | 579 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 30 | 13.97 | 730 | 7 | 7 |
2 | 1006.84 | 80 | 7.96 | 2156 | 7 | 6 |
3 | 343.00 | 36 | 13.34 | 1202 | 6 | 8 |
4 | 70.16 | 36 | 13.91 | 700 | 6 | 8 |
5 | 0.08 | 181 | 14.02 | 570 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.16 | 30 | 13.91 | 730 | 7 | 6 |
2 | 1137.04 | 36 | 10.77 | 2439 | 6 | 6 |
3 | 1289.96 | 80 | 10.08 | 2636 | 6 | 6 |
4 | 362.56 | 37 | 13.26 | 1272 | 6 | 9 |
5 | 31.12 | 37 | 13.95 | 664 | 6 | 9 |
6 | 0.00 | 180 | 14.03 | 585 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.80 | 30 | 13.91 | 711 | 7 | 7 |
2 | 1005.92 | 80 | 6.83 | 2076 | 7 | 6 |
3 | 841.00 | 36 | 12.22 | 2029 | 6 | 7 |
4 | 118.44 | 36 | 13.70 | 818 | 6 | 8 |
5 | 0.00 | 181 | 14.00 | 562 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.92 | 30 | 13.97 | 750 | 7 | 7 |
2 | 1010.72 | 80 | 7.10 | 2061 | 6 | 6 |
3 | 660.92 | 36 | 12.72 | 1700 | 6 | 8 |
4 | 73.68 | 36 | 13.87 | 708 | 6 | 8 |
5 | 0.08 | 181 | 14.02 | 570 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 30 | 14.04 | 730 | 7 | 7 |
2 | 1012.24 | 80 | 7.57 | 2116 | 6 | 6 |
3 | 519.08 | 36 | 13.08 | 1498 | 6 | 8 |
4 | 73.12 | 37 | 13.87 | 711 | 6 | 8 |
5 | 0.04 | 181 | 14.06 | 565 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.00 | 32 | 13.97 | 730 | 6 | 6 |
2 | 930.92 | -1 | 13.97 | 730 | 6 | 6 |
3 | 1119.60 | 36 | 10.54 | 2403 | 6 | 6 |
4 | 1291.60 | 80 | 10.04 | 2635 | 6 | 6 |
5 | 363.88 | 37 | 13.31 | 1229 | 6 | 9 |
6 | 36.68 | 37 | 13.97 | 641 | 6 | 8 |
7 | 0.04 | 181 | 14.07 | 569 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.36 | 30 | 13.91 | 730 | 7 | 7 |
2 | 1003.80 | 37 | 5.23 | 2008 | 7 | 6 |
3 | 928.76 | 36 | 11.53 | 2116 | 6 | 6 |
4 | 597.24 | 36 | 12.79 | 1609 | 6 | 8 |
5 | 85.72 | 36 | 13.79 | 730 | 6 | 8 |
6 | 0.00 | 181 | 14.02 | 569 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 30 | 13.97 | 711 | 7 | 7 |
2 | 1015.56 | 37 | 5.72 | 2006 | 6 | 6 |
3 | 925.32 | 37 | 11.52 | 2100 | 6 | 6 |
4 | 585.24 | 37 | 12.72 | 1593 | 6 | 8 |
5 | 73.92 | 36 | 13.81 | 732 | 6 | 9 |
6 | 0.00 | 181 | 14.01 | 578 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 30 | 14.17 | 730 | 7 | 7 |
2 | 1010.08 | 37 | 7.10 | 2067 | 6 | 6 |
3 | 892.16 | 37 | 11.88 | 2045 | 6 | 6 |
4 | 346.52 | 37 | 13.28 | 1166 | 6 | 9 |
5 | 28.36 | 36 | 14.00 | 588 | 6 | 9 |
6 | 0.04 | 181 | 14.10 | 528 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 25 | 14.10 | 673 | 7 | 7 |
2 | 1038.80 | 6 | 12.06 | 2288 | 6 | 6 |
3 | 1039.24 | 1 | 10.35 | 2307 | 6 | 6 |
4 | 1167.36 | 36 | 10.79 | 2458 | 6 | 6 |
5 | 1264.88 | 37 | 11.62 | 2640 | 6 | 6 |
6 | 1111.72 | 37 | 12.38 | 2394 | 6 | 6 |
7 | 169.76 | 37 | 13.79 | 849 | 6 | 8 |
8 | 0.12 | 181 | 14.22 | 506 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 30 | 14.04 | 711 | 7 | 7 |
2 | 1168.48 | 36 | 6.01 | 2281 | 6 | 6 |
3 | 1774.16 | 100 | 4.98 | 3087 | 6 | 6 |
4 | 1770.88 | 88 | 5.15 | 3371 | 6 | 6 |
5 | 1756.52 | 38 | 10.30 | 3375 | 6 | 6 |
6 | 1420.08 | 36 | 12.16 | 2903 | 6 | 6 |
7 | 647.12 | 36 | 13.16 | 1680 | 6 | 9 |
8 | 57.92 | 36 | 14.03 | 676 | 6 | 8 |
9 | 0.12 | 181 | 14.23 | 543 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.68 | 30 | 14.17 | 673 | 7 | 7 |
2 | 1147.88 | 36 | 6.12 | 2241 | 6 | 6 |
3 | 1779.00 | 100 | 4.95 | 3052 | 6 | 6 |
4 | 1777.72 | 88 | 5.08 | 3342 | 6 | 6 |
5 | 1772.84 | 37 | 9.68 | 3382 | 6 | 6 |
6 | 1616.96 | 37 | 11.78 | 3166 | 6 | 6 |
7 | 535.68 | 37 | 13.25 | 1491 | 6 | 9 |
8 | 78.92 | 37 | 13.96 | 698 | 6 | 8 |
9 | 0.08 | 181 | 14.22 | 540 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.84 | 30 | 14.10 | 673 | 7 | 7 |
2 | 1151.96 | 36 | 6.12 | 2260 | 6 | 6 |
3 | 1761.20 | 100 | 5.01 | 3123 | 6 | 6 |
4 | 1758.24 | 88 | 5.88 | 3199 | 6 | 6 |
5 | 1747.84 | 38 | 9.72 | 3349 | 6 | 6 |
6 | 1203.80 | 36 | 12.49 | 2547 | 6 | 6 |
7 | 241.92 | 36 | 13.66 | 972 | 6 | 10 |
8 | 0.40 | 181 | 14.21 | 509 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.16 | 30 | 14.23 | 653 | 7 | 7 |
2 | 1148.08 | 36 | 6.09 | 2299 | 6 | 6 |
3 | 1865.40 | 100 | 4.93 | 3180 | 6 | 6 |
4 | 1863.52 | 88 | 5.12 | 3497 | 6 | 6 |
5 | 1858.04 | 37 | 9.72 | 3508 | 6 | 6 |
6 | 1700.76 | 35 | 11.86 | 3314 | 6 | 6 |
7 | 941.56 | 35 | 12.91 | 2097 | 6 | 7 |
8 | 159.28 | 35 | 13.84 | 841 | 6 | 9 |
9 | 0.12 | 181 | 14.26 | 505 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.44 | 30 | 14.29 | 634 | 7 | 6 |
2 | 1170.80 | 36 | 5.74 | 2336 | 6 | 6 |
3 | 1893.88 | 100 | 4.88 | 3162 | 6 | 6 |
4 | 1891.56 | 88 | 5.03 | 3472 | 6 | 6 |
5 | 1885.44 | 38 | 9.64 | 3575 | 6 | 6 |
6 | 1736.56 | 35 | 11.78 | 3380 | 6 | 6 |
7 | 861.28 | 35 | 12.94 | 1985 | 6 | 7 |
8 | 148.64 | 35 | 13.88 | 819 | 6 | 8 |
9 | 8.44 | 35 | 14.19 | 529 | 6 | 9 |
10 | -0.04 | 181 | 14.28 | 511 | 6 | 40 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.56 | 30 | 14.29 | 634 | 7 | 6 |
2 | 1153.88 | 36 | 5.91 | 2272 | 6 | 6 |
3 | 1844.96 | 100 | 4.94 | 3181 | 6 | 6 |
4 | 1841.76 | 88 | 5.19 | 3509 | 6 | 6 |
5 | 1833.28 | 38 | 9.75 | 3489 | 6 | 6 |
6 | 1528.56 | 35 | 12.15 | 3076 | 6 | 6 |
7 | 983.68 | 35 | 12.92 | 2141 | 6 | 7 |
8 | 88.72 | 35 | 14.02 | 671 | 6 | 8 |
9 | 0.00 | 181 | 14.29 | 492 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 30 | 14.23 | 673 | 7 | 7 |
2 | 1158.72 | 36 | 5.83 | 2310 | 6 | 6 |
3 | 1911.28 | 100 | 4.90 | 3245 | 6 | 6 |
4 | 1908.64 | 88 | 5.22 | 3599 | 6 | 6 |
5 | 1901.08 | 38 | 9.81 | 3571 | 6 | 6 |
6 | 1586.64 | 35 | 12.16 | 3156 | 6 | 6 |
7 | 875.44 | 35 | 13.02 | 2007 | 6 | 7 |
8 | 130.20 | 35 | 13.95 | 786 | 6 | 9 |
9 | 0.12 | 181 | 14.26 | 515 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.00 | 30 | 14.29 | 653 | 7 | 7 |
2 | 1146.96 | 36 | 5.75 | 2245 | 6 | 6 |
3 | 1896.60 | 100 | 4.88 | 3257 | 6 | 6 |
4 | 1894.48 | 88 | 5.34 | 3595 | 6 | 6 |
5 | 1886.76 | 38 | 9.93 | 3524 | 6 | 6 |
6 | 1720.80 | 35 | 12.05 | 3327 | 6 | 6 |
7 | 990.76 | 35 | 12.93 | 2150 | 6 | 7 |
8 | 102.32 | 35 | 14.00 | 712 | 6 | 8 |
9 | 0.04 | 181 | 14.28 | 503 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.04 | 30 | 14.36 | 634 | 7 | 7 |
2 | 1166.52 | 36 | 5.38 | 2226 | 6 | 6 |
3 | 1982.20 | 100 | 4.84 | 3156 | 6 | 6 |
4 | 1981.80 | 88 | 5.08 | 3535 | 6 | 6 |
5 | 1977.36 | 37 | 9.74 | 3708 | 6 | 6 |
6 | 1849.88 | 35 | 11.92 | 3543 | 6 | 6 |
7 | 1128.68 | 35 | 12.82 | 2411 | 6 | 6 |
8 | 206.00 | 35 | 13.84 | 893 | 6 | 9 |
9 | 31.48 | 35 | 14.21 | 561 | 6 | 9 |
10 | 0.00 | 181 | 14.31 | 498 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 30 | 14.23 | 634 | 7 | 7 |
2 | 1160.00 | 36 | 5.30 | 2263 | 6 | 6 |
3 | 2000.16 | 100 | 4.99 | 3323 | 6 | 6 |
4 | 1998.40 | 51 | 5.54 | 3612 | 6 | 6 |
5 | 1993.56 | 38 | 9.62 | 3705 | 6 | 6 |
6 | 1841.24 | 35 | 11.99 | 3505 | 6 | 6 |
7 | 1139.84 | 35 | 12.81 | 2382 | 6 | 6 |
8 | 190.60 | 35 | 13.83 | 864 | 6 | 9 |
9 | -0.08 | 181 | 14.28 | 500 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.60 | 30 | 14.29 | 634 | 7 | 7 |
2 | 1154.12 | 36 | 5.62 | 2220 | 6 | 6 |
3 | 1969.84 | 100 | 4.95 | 3325 | 6 | 6 |
4 | 1969.00 | 51 | 5.84 | 3582 | 6 | 6 |
5 | 1965.36 | 38 | 9.74 | 3657 | 6 | 6 |
6 | 1816.84 | 35 | 11.96 | 3480 | 6 | 6 |
7 | 884.00 | 35 | 13.05 | 1981 | 6 | 7 |
8 | 145.12 | 35 | 13.94 | 792 | 6 | 9 |
9 | 0.16 | 181 | 14.30 | 497 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.04 | 30 | 14.23 | 653 | 7 | 7 |
2 | 1149.44 | 36 | 5.44 | 2165 | 6 | 6 |
3 | 1994.44 | 100 | 4.92 | 3291 | 6 | 6 |
4 | 1992.08 | 51 | 5.61 | 3599 | 6 | 6 |
5 | 1987.28 | 38 | 9.74 | 3702 | 6 | 6 |
6 | 1822.20 | 35 | 12.04 | 3470 | 6 | 6 |
7 | 1101.64 | 35 | 12.84 | 2333 | 6 | 7 |
8 | 151.52 | 35 | 13.92 | 809 | 6 | 9 |
9 | 0.08 | 180 | 14.29 | 499 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.68 | 30 | 14.29 | 634 | 7 | 7 |
2 | 1159.12 | 28 | 5.44 | 2176 | 6 | 6 |
3 | 2002.64 | 70 | 5.02 | 3448 | 6 | 6 |
4 | 2003.64 | 50 | 5.85 | 3622 | 6 | 6 |
5 | 2000.64 | 37 | 9.58 | 3707 | 6 | 6 |
6 | 1854.52 | 35 | 12.01 | 3532 | 6 | 6 |
7 | 946.36 | 35 | 13.06 | 2053 | 6 | 7 |
8 | 198.08 | 35 | 13.87 | 874 | 6 | 9 |
9 | 0.16 | 180 | 14.28 | 492 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.16 | 30 | 14.29 | 634 | 7 | 7 |
2 | 1162.52 | 28 | 4.94 | 2153 | 6 | 6 |
3 | 2004.64 | 70 | 5.13 | 3426 | 6 | 6 |
4 | 2007.32 | 50 | 5.78 | 3568 | 6 | 6 |
5 | 2006.60 | 37 | 9.56 | 3697 | 6 | 6 |
6 | 1881.56 | 35 | 12.07 | 3553 | 6 | 6 |
7 | 997.88 | 35 | 13.00 | 2147 | 6 | 6 |
8 | 259.28 | 35 | 13.79 | 972 | 6 | 10 |
9 | 3.32 | 35 | 14.25 | 506 | 6 | 7 |
10 | 0.00 | 180 | 14.29 | 495 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 30 | 14.29 | 634 | 7 | 7 |
2 | 1159.92 | 18 | 4.62 | 2013 | 6 | 7 |
3 | 2008.20 | 22 | 4.90 | 3392 | 6 | 6 |
4 | 2009.40 | 53 | 5.31 | 3346 | 6 | 6 |
5 | 2012.20 | 37 | 8.48 | 3683 | 6 | 6 |
6 | 1904.48 | 34 | 11.88 | 3585 | 6 | 6 |
7 | 1251.88 | 34 | 12.77 | 2546 | 6 | 6 |
8 | 514.08 | 34 | 13.46 | 1407 | 6 | 9 |
9 | 62.88 | 34 | 14.13 | 623 | 6 | 9 |
10 | 0.08 | 180 | 14.31 | 480 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.12 | 30 | 14.17 | 673 | 7 | 7 |
2 | 1162.28 | 18 | 4.62 | 2005 | 6 | 7 |
3 | 2004.72 | 22 | 4.89 | 3424 | 6 | 6 |
4 | 2005.84 | 53 | 5.38 | 3413 | 6 | 6 |
5 | 2008.12 | 38 | 8.77 | 3681 | 6 | 6 |
6 | 1890.88 | 35 | 11.96 | 3553 | 6 | 6 |
7 | 1378.08 | 35 | 12.62 | 2763 | 6 | 6 |
8 | 611.36 | 35 | 13.37 | 1566 | 6 | 9 |
9 | 77.80 | 35 | 14.12 | 653 | 6 | 9 |
10 | 0.00 | 181 | 14.26 | 500 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 30 | 14.23 | 615 | 7 | 7 |
2 | 1154.00 | 18 | 4.97 | 2115 | 6 | 6 |
3 | 2006.32 | 22 | 4.93 | 3612 | 6 | 6 |
4 | 2007.64 | 53 | 5.61 | 3630 | 6 | 6 |
5 | 2009.56 | 38 | 9.18 | 3664 | 6 | 6 |
6 | 1892.56 | 35 | 11.95 | 3555 | 6 | 6 |
7 | 1362.36 | 35 | 12.67 | 2685 | 6 | 6 |
8 | 381.44 | 35 | 13.59 | 1169 | 6 | 10 |
9 | 14.32 | 35 | 14.26 | 520 | 6 | 8 |
10 | 0.04 | 181 | 14.28 | 491 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.24 | 30 | 14.23 | 673 | 7 | 6 |
2 | 1145.92 | 18 | 5.46 | 2139 | 6 | 6 |
3 | 2002.56 | 22 | 5.30 | 3743 | 6 | 6 |
4 | 2003.40 | 53 | 6.84 | 3604 | 6 | 6 |
5 | 2000.52 | 38 | 9.66 | 3673 | 6 | 6 |
6 | 1658.72 | 35 | 12.27 | 3175 | 6 | 6 |
7 | 761.24 | 35 | 13.22 | 1749 | 6 | 8 |
8 | 95.32 | 35 | 14.09 | 660 | 6 | 8 |
9 | 0.16 | 181 | 14.28 | 486 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.52 | 30 | 14.29 | 634 | 7 | 6 |
2 | 1153.00 | 15 | 5.56 | 2050 | 6 | 6 |
3 | 2000.04 | 21 | 5.64 | 3700 | 6 | 6 |
4 | 2000.72 | 43 | 7.29 | 3573 | 6 | 6 |
5 | 1999.92 | 37 | 8.96 | 3629 | 6 | 6 |
6 | 1839.32 | 51 | 11.61 | 3424 | 6 | 6 |
7 | 682.68 | 51 | 13.10 | 1616 | 6 | 9 |
8 | 15.72 | 51 | 14.24 | 512 | 6 | 10 |
9 | 0.00 | 181 | 14.25 | 495 | 6 | 44 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 30 | 14.36 | 615 | 7 | 6 |
2 | 1144.20 | 15 | 5.86 | 2057 | 6 | 6 |
3 | 2005.96 | 21 | 5.03 | 3997 | 6 | 6 |
4 | 2006.88 | 43 | 7.76 | 3602 | 6 | 6 |
5 | 2006.76 | 37 | 8.97 | 3634 | 6 | 6 |
6 | 1846.60 | 51 | 11.47 | 3446 | 6 | 6 |
7 | 662.52 | 51 | 13.17 | 1583 | 6 | 10 |
8 | 34.64 | 51 | 14.19 | 547 | 6 | 11 |
9 | -0.08 | 180 | 14.26 | 485 | 6 | 41 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.28 | 30 | 14.23 | 615 | 7 | 6 |
2 | 1153.12 | 12 | 5.26 | 2068 | 6 | 6 |
3 | 2004.36 | 42 | 6.55 | 3679 | 6 | 6 |
4 | 2006.24 | 37 | 8.73 | 3593 | 6 | 6 |
5 | 1879.48 | 51 | 11.39 | 3483 | 6 | 6 |
6 | 967.20 | 51 | 12.77 | 2041 | 6 | 8 |
7 | 61.96 | 51 | 14.17 | 587 | 6 | 10 |
8 | -0.08 | 181 | 14.29 | 482 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.20 | 30 | 14.36 | 615 | 7 | 6 |
2 | 1137.68 | 12 | 5.57 | 1988 | 6 | 6 |
3 | 2004.64 | 42 | 6.70 | 3699 | 6 | 6 |
4 | 2005.56 | 37 | 8.79 | 3620 | 6 | 6 |
5 | 1867.04 | 51 | 11.39 | 3462 | 6 | 6 |
6 | 1074.56 | 51 | 12.64 | 2192 | 6 | 8 |
7 | 76.40 | 51 | 14.10 | 618 | 6 | 10 |
8 | 0.00 | 181 | 14.27 | 465 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 30 | 14.23 | 634 | 7 | 7 |
2 | 1149.76 | 12 | 5.73 | 2026 | 6 | 6 |
3 | 2000.28 | 42 | 7.24 | 3569 | 6 | 6 |
4 | 2000.96 | 37 | 8.96 | 3585 | 6 | 6 |
5 | 1843.52 | 51 | 11.42 | 3399 | 6 | 6 |
6 | 725.28 | 51 | 13.04 | 1692 | 6 | 9 |
7 | 41.44 | 51 | 14.19 | 547 | 6 | 11 |
8 | -0.04 | 181 | 14.27 | 464 | 6 | 42 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 30 | 14.23 | 615 | 7 | 7 |
2 | 1142.84 | 13 | 6.03 | 2044 | 6 | 6 |
3 | 2000.56 | 42 | 7.38 | 3626 | 6 | 6 |
4 | 2000.84 | 37 | 9.08 | 3612 | 6 | 6 |
5 | 1852.04 | 51 | 11.43 | 3416 | 6 | 6 |
6 | 547.88 | 51 | 13.28 | 1387 | 6 | 10 |
7 | 44.32 | 51 | 14.15 | 547 | 6 | 11 |
8 | 0.08 | 181 | 14.24 | 466 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.12 | 30 | 14.42 | 596 | 7 | 7 |
2 | 1145.16 | 12 | 5.86 | 2041 | 6 | 6 |
3 | 2006.84 | 42 | 7.63 | 3690 | 6 | 6 |
4 | 2007.48 | 37 | 9.15 | 3604 | 6 | 6 |
5 | 1849.00 | 51 | 11.43 | 3435 | 6 | 6 |
6 | 695.28 | 51 | 13.11 | 1589 | 6 | 9 |
7 | 6.52 | 51 | 14.29 | 468 | 6 | 10 |
8 | 0.00 | 181 | 14.26 | 459 | 6 | 43 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.88 | 30 | 14.36 | 615 | 7 | 6 |
2 | 1161.40 | 12 | 5.48 | 2149 | 6 | 6 |
3 | 2000.40 | 42 | 8.03 | 3587 | 6 | 6 |
4 | 2000.64 | 37 | 9.21 | 3607 | 6 | 6 |
5 | 1847.36 | 51 | 11.46 | 3427 | 6 | 6 |
6 | 680.92 | 51 | 13.13 | 1593 | 6 | 9 |
7 | 0.12 | 181 | 14.23 | 464 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.56 | 30 | 14.23 | 596 | 7 | 6 |
2 | 1161.28 | 13 | 6.73 | 2095 | 6 | 6 |
3 | 2005.60 | 42 | 8.07 | 3576 | 6 | 6 |
4 | 2005.40 | 37 | 9.23 | 3602 | 6 | 6 |
5 | 1685.80 | 51 | 11.70 | 3154 | 6 | 6 |
6 | 524.60 | 51 | 13.32 | 1355 | 6 | 11 |
7 | 44.00 | 51 | 14.16 | 547 | 6 | 11 |
8 | -0.04 | 181 | 14.24 | 461 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.76 | 30 | 14.29 | 596 | 7 | 7 |
2 | 1147.96 | 12 | 6.62 | 2057 | 6 | 6 |
3 | 2003.04 | 42 | 7.99 | 3664 | 6 | 6 |
4 | 2003.44 | 37 | 9.34 | 3571 | 6 | 6 |
5 | 1549.64 | 51 | 11.93 | 2949 | 6 | 6 |
6 | 296.00 | 51 | 13.68 | 982 | 6 | 11 |
7 | 0.12 | 181 | 14.22 | 463 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.72 | 30 | 14.42 | 596 | 7 | 7 |
2 | 1142.52 | 12 | 6.49 | 2134 | 6 | 6 |
3 | 2001.28 | 42 | 8.37 | 3587 | 6 | 6 |
4 | 2000.96 | 37 | 9.37 | 3593 | 6 | 6 |
5 | 1686.84 | 51 | 11.75 | 3148 | 6 | 6 |
6 | 373.92 | 51 | 13.53 | 1117 | 6 | 11 |
7 | 0.08 | 181 | 14.22 | 466 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 30 | 14.29 | 634 | 6 | 6 |
2 | 1150.00 | 12 | 6.78 | 2099 | 6 | 6 |
3 | 2003.84 | 42 | 8.08 | 3731 | 6 | 6 |
4 | 2003.48 | 37 | 9.43 | 3625 | 6 | 6 |
5 | 1535.76 | 51 | 11.92 | 2928 | 6 | 6 |
6 | 408.04 | 51 | 13.49 | 1165 | 6 | 11 |
7 | 0.08 | 181 | 14.24 | 461 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.44 | 30 | 14.36 | 615 | 7 | 7 |
2 | 1160.16 | 10 | 6.42 | 2062 | 6 | 6 |
3 | 2003.32 | 42 | 8.30 | 3554 | 6 | 6 |
4 | 2003.84 | 37 | 9.43 | 3607 | 6 | 6 |
5 | 1537.64 | 51 | 11.98 | 2916 | 6 | 6 |
6 | 248.92 | 51 | 13.75 | 899 | 6 | 11 |
7 | 0.08 | 191 | 14.23 | 461 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 30 | 14.36 | 596 | 7 | 6 |
2 | 1135.88 | 10 | 6.50 | 2071 | 6 | 6 |
3 | 2001.24 | 42 | 8.15 | 3693 | 6 | 6 |
4 | 2001.08 | 37 | 9.60 | 3591 | 6 | 6 |
5 | 1699.88 | 51 | 11.80 | 3151 | 6 | 6 |
6 | 373.20 | 51 | 13.52 | 1115 | 6 | 11 |
7 | 0.04 | 190 | 14.23 | 458 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 30 | 14.36 | 596 | 7 | 7 |
2 | 1163.76 | 10 | 6.90 | 2167 | 6 | 6 |
3 | 2005.48 | 33 | 8.67 | 3641 | 6 | 6 |
4 | 2006.24 | 38 | 9.57 | 3626 | 6 | 6 |
5 | 1575.84 | 51 | 11.89 | 2986 | 6 | 6 |
6 | 307.56 | 51 | 13.65 | 996 | 6 | 11 |
7 | 0.36 | 190 | 14.23 | 452 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.20 | 30 | 14.23 | 615 | 7 | 7 |
2 | 1161.76 | 10 | 7.13 | 2244 | 6 | 6 |
3 | 2006.96 | 33 | 8.94 | 3574 | 6 | 6 |
4 | 2007.32 | 38 | 9.62 | 3598 | 6 | 6 |
5 | 1699.48 | 51 | 11.71 | 3159 | 6 | 6 |
6 | 401.32 | 51 | 13.50 | 1146 | 6 | 11 |
7 | 0.04 | 190 | 14.24 | 453 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.16 | 30 | 14.29 | 596 | 7 | 7 |
2 | 1156.92 | 10 | 7.82 | 2158 | 6 | 6 |
3 | 2000.52 | 33 | 8.67 | 3668 | 6 | 6 |
4 | 2000.36 | 38 | 9.64 | 3591 | 6 | 6 |
5 | 1532.32 | 51 | 11.94 | 2902 | 6 | 6 |
6 | 414.20 | 51 | 13.45 | 1183 | 6 | 11 |
7 | 0.04 | 191 | 14.21 | 456 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 30 | 14.23 | 596 | 7 | 7 |
2 | 1149.24 | 11 | 8.53 | 2195 | 6 | 6 |
3 | 2003.68 | 33 | 8.96 | 3731 | 6 | 6 |
4 | 2003.16 | 36 | 9.83 | 3603 | 6 | 6 |
5 | 1525.20 | 48 | 11.98 | 2896 | 6 | 6 |
6 | 268.88 | 48 | 13.69 | 923 | 6 | 10 |
7 | 3.72 | 48 | 14.30 | 448 | 6 | 9 |
8 | 0.00 | 191 | 14.22 | 440 | 6 | 46 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 30 | 14.23 | 596 | 6 | 6 |
2 | 1158.92 | 11 | 8.53 | 2203 | 6 | 6 |
3 | 1994.52 | 33 | 8.87 | 3674 | 6 | 6 |
4 | 1993.56 | 36 | 9.73 | 3595 | 6 | 6 |
5 | 1680.36 | 47 | 11.76 | 3142 | 6 | 6 |
6 | 379.96 | 48 | 13.53 | 1111 | 6 | 10 |
7 | 27.56 | 47 | 14.25 | 492 | 6 | 11 |
8 | 0.00 | 191 | 14.22 | 448 | 6 | 48 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.08 | 30 | 14.29 | 615 | 7 | 7 |
2 | 1160.48 | 11 | 8.74 | 2203 | 6 | 6 |
3 | 2001.08 | 33 | 9.15 | 3600 | 6 | 6 |
4 | 1999.96 | 36 | 9.79 | 3595 | 6 | 6 |
5 | 1504.00 | 48 | 12.01 | 2837 | 6 | 6 |
6 | 354.88 | 48 | 13.59 | 1068 | 6 | 11 |
7 | 0.08 | 191 | 14.24 | 441 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.08 | 30 | 14.29 | 596 | 7 | 7 |
2 | 1141.20 | 11 | 8.34 | 2195 | 6 | 6 |
3 | 2011.84 | 33 | 8.78 | 3665 | 6 | 6 |
4 | 2011.00 | 36 | 9.94 | 3614 | 6 | 6 |
5 | 1546.88 | 47 | 11.97 | 2930 | 6 | 6 |
6 | 301.32 | 48 | 13.69 | 984 | 6 | 10 |
7 | 0.04 | 191 | 14.26 | 442 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 30 | 14.29 | 615 | 7 | 6 |
2 | 1153.88 | 10 | 8.04 | 2182 | 6 | 6 |
3 | 2003.92 | 65 | 9.25 | 3603 | 6 | 6 |
4 | 1696.56 | 47 | 11.79 | 3150 | 6 | 6 |
5 | 405.28 | 47 | 13.56 | 1145 | 6 | 10 |
6 | 39.16 | 47 | 14.26 | 500 | 6 | 10 |
7 | 0.00 | 191 | 14.27 | 438 | 6 | 44 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.40 | 30 | 14.29 | 596 | 7 | 7 |
2 | 1138.72 | 10 | 8.64 | 2197 | 6 | 6 |
3 | 2006.92 | 65 | 9.30 | 3615 | 6 | 6 |
4 | 1538.92 | 47 | 11.98 | 2910 | 6 | 6 |
5 | 607.24 | 47 | 13.22 | 1471 | 6 | 10 |
6 | 30.40 | 47 | 14.26 | 492 | 6 | 10 |
7 | 0.00 | 191 | 14.27 | 438 | 6 | 40 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.04 | 30 | 14.29 | 615 | 7 | 7 |
2 | 1148.76 | 10 | 8.86 | 2211 | 6 | 6 |
3 | 2006.64 | 65 | 9.43 | 3612 | 6 | 6 |
4 | 1552.32 | 47 | 12.00 | 2925 | 6 | 6 |
5 | 321.96 | 47 | 13.63 | 1009 | 6 | 10 |
6 | 22.04 | 47 | 14.23 | 476 | 6 | 10 |
7 | 0.00 | 191 | 14.25 | 436 | 6 | 43 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 30 | 14.23 | 596 | 7 | 7 |
2 | 1145.92 | 10 | 9.07 | 2220 | 6 | 6 |
3 | 2001.60 | 65 | 9.49 | 3616 | 6 | 6 |
4 | 1533.16 | 47 | 11.99 | 2892 | 6 | 6 |
5 | 424.52 | 47 | 13.47 | 1160 | 6 | 10 |
6 | 0.08 | 190 | 14.27 | 427 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.08 | 30 | 14.36 | 596 | 7 | 7 |
2 | 1155.28 | 10 | 9.21 | 2254 | 6 | 6 |
3 | 2001.52 | 65 | 9.75 | 3614 | 6 | 6 |
4 | 1389.48 | 47 | 12.20 | 2678 | 6 | 6 |
5 | 289.44 | 47 | 13.73 | 951 | 6 | 10 |
6 | 0.12 | 191 | 14.27 | 435 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.92 | 30 | 14.23 | 615 | 7 | 7 |
2 | 1161.12 | 7 | 8.55 | 2281 | 6 | 6 |
3 | 2005.52 | 52 | 9.84 | 3598 | 6 | 6 |
4 | 1700.92 | 51 | 11.77 | 3162 | 6 | 6 |
5 | 455.52 | 51 | 13.46 | 1225 | 6 | 10 |
6 | 5.64 | 51 | 14.33 | 445 | 6 | 7 |
7 | 0.04 | 191 | 14.21 | 444 | 6 | 41 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.00 | 30 | 14.36 | 576 | 7 | 6 |
2 | 1142.24 | 7 | 8.79 | 2269 | 6 | 6 |
3 | 2005.00 | 52 | 9.95 | 3603 | 6 | 6 |
4 | 1864.60 | 51 | 11.59 | 3396 | 6 | 6 |
5 | 560.20 | 51 | 13.28 | 1391 | 6 | 10 |
6 | 1.16 | 51 | 14.33 | 441 | 6 | 7 |
7 | 0.04 | 191 | 14.21 | 439 | 6 | 44 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 30 | 14.29 | 576 | 6 | 6 |
2 | 1167.04 | 7 | 8.83 | 2320 | 6 | 6 |
3 | 2004.36 | 52 | 9.89 | 3611 | 6 | 6 |
4 | 1859.96 | 51 | 11.50 | 3419 | 6 | 6 |
5 | 568.64 | 51 | 13.29 | 1394 | 6 | 9 |
6 | 0.56 | 190 | 14.24 | 434 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.76 | 30 | 14.29 | 596 | 7 | 7 |
2 | 1147.36 | 7 | 9.06 | 2345 | 6 | 6 |
3 | 2000.24 | 52 | 9.97 | 3625 | 6 | 6 |
4 | 1711.76 | 51 | 11.79 | 3165 | 6 | 6 |
5 | 578.56 | 51 | 13.26 | 1401 | 6 | 9 |
6 | 0.16 | 191 | 14.22 | 432 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.04 | 30 | 14.36 | 596 | 7 | 7 |
2 | 1157.36 | 7 | 9.22 | 2345 | 6 | 6 |
3 | 2003.32 | 52 | 9.98 | 3617 | 6 | 6 |
4 | 1853.08 | 51 | 11.48 | 3391 | 6 | 6 |
5 | 554.76 | 51 | 13.29 | 1375 | 6 | 10 |
6 | 44.36 | 51 | 14.19 | 523 | 6 | 11 |
7 | 0.08 | 190 | 14.22 | 442 | 6 | 43 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.32 | 30 | 14.23 | 596 | 7 | 7 |
2 | 1142.80 | 7 | 9.21 | 2352 | 6 | 6 |
3 | 2003.60 | 52 | 10.06 | 3602 | 6 | 6 |
4 | 1702.52 | 51 | 11.75 | 3133 | 6 | 6 |
5 | 437.40 | 51 | 13.47 | 1177 | 6 | 10 |
6 | 0.12 | 190 | 14.24 | 434 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.56 | 30 | 14.23 | 615 | 7 | 7 |
2 | 1146.72 | 7 | 9.15 | 2403 | 6 | 6 |
3 | 2002.84 | 52 | 10.11 | 3610 | 6 | 6 |
4 | 1717.32 | 51 | 11.77 | 3157 | 6 | 6 |
5 | 597.88 | 51 | 13.27 | 1430 | 6 | 9 |
6 | 14.12 | 51 | 14.31 | 452 | 6 | 10 |
7 | 0.00 | 191 | 14.19 | 438 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.84 | 29 | 14.36 | 596 | 7 | 6 |
2 | 1156.68 | 7 | 9.30 | 2422 | 6 | 6 |
3 | 2002.12 | 52 | 10.21 | 3582 | 6 | 6 |
4 | 1698.08 | 54 | 11.71 | 3136 | 6 | 6 |
5 | 429.32 | 54 | 13.45 | 1169 | 6 | 11 |
6 | 0.08 | 191 | 14.21 | 431 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 29 | 14.23 | 596 | 6 | 6 |
2 | 1164.80 | 7 | 9.34 | 2441 | 6 | 6 |
3 | 2001.12 | 52 | 10.26 | 3591 | 6 | 6 |
4 | 1688.44 | 54 | 11.69 | 3114 | 6 | 6 |
5 | 381.80 | 54 | 13.54 | 1095 | 6 | 11 |
6 | 0.12 | 190 | 14.22 | 430 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.04 | 29 | 14.36 | 576 | 7 | 7 |
2 | 1166.76 | 7 | 9.92 | 2378 | 6 | 6 |
3 | 2007.12 | 52 | 10.23 | 3611 | 6 | 6 |
4 | 1571.52 | 54 | 11.86 | 2937 | 6 | 6 |
5 | 310.96 | 54 | 13.65 | 978 | 6 | 11 |
6 | 0.08 | 190 | 14.23 | 426 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.76 | 29 | 14.23 | 596 | 7 | 6 |
2 | 1164.40 | 7 | 9.81 | 2390 | 6 | 6 |
3 | 2003.56 | 52 | 10.26 | 3591 | 6 | 6 |
4 | 1856.12 | 54 | 11.49 | 3387 | 6 | 6 |
5 | 694.88 | 54 | 13.07 | 1574 | 6 | 10 |
6 | 0.12 | 191 | 14.24 | 429 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.12 | 29 | 14.36 | 596 | 6 | 6 |
2 | 1161.52 | 7 | 10.21 | 2313 | 6 | 6 |
3 | 2022.96 | 52 | 10.09 | 3643 | 6 | 6 |
4 | 1575.52 | 54 | 11.90 | 2929 | 6 | 6 |
5 | 336.80 | 54 | 13.63 | 1013 | 6 | 11 |
6 | 0.08 | 191 | 14.23 | 420 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.12 | 29 | 14.36 | 596 | 6 | 6 |
2 | 1163.24 | 7 | 10.41 | 2307 | 6 | 6 |
3 | 2002.68 | 52 | 10.26 | 3591 | 6 | 6 |
4 | 1696.24 | 54 | 11.69 | 3116 | 6 | 6 |
5 | 542.80 | 54 | 13.27 | 1357 | 6 | 11 |
6 | -0.04 | 191 | 14.22 | 426 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.00 | 29 | 14.36 | 596 | 6 | 6 |
2 | 1159.56 | 7 | 10.59 | 2300 | 6 | 6 |
3 | 2002.36 | 52 | 10.48 | 3576 | 6 | 6 |
4 | 1535.92 | 54 | 11.92 | 2874 | 6 | 6 |
5 | 291.72 | 54 | 13.69 | 939 | 6 | 11 |
6 | 0.12 | 191 | 14.22 | 428 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 29 | 14.36 | 576 | 7 | 6 |
2 | 1150.40 | 7 | 10.66 | 2313 | 6 | 6 |
3 | 2020.68 | 52 | 10.33 | 3631 | 6 | 6 |
4 | 1879.48 | 54 | 11.46 | 3408 | 6 | 6 |
5 | 431.48 | 54 | 13.47 | 1168 | 6 | 10 |
6 | 0.00 | 191 | 14.21 | 441 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.60 | 29 | 14.23 | 596 | 6 | 6 |
2 | 1165.32 | 7 | 10.74 | 2326 | 6 | 6 |
3 | 2002.64 | 52 | 10.47 | 3577 | 6 | 6 |
4 | 1851.60 | 54 | 11.49 | 3359 | 6 | 6 |
5 | 520.88 | 54 | 13.35 | 1301 | 6 | 10 |
6 | 0.08 | 190 | 14.19 | 439 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.64 | 29 | 14.36 | 576 | 7 | 6 |
2 | 1142.36 | 7 | 10.77 | 2307 | 6 | 6 |
3 | 2001.44 | 52 | 10.47 | 3568 | 6 | 6 |
4 | 1864.20 | 54 | 11.48 | 3395 | 6 | 6 |
5 | 529.20 | 54 | 13.31 | 1309 | 6 | 10 |
6 | 0.12 | 190 | 14.20 | 437 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 29 | 14.23 | 596 | 7 | 6 |
2 | 1163.00 | 7 | 10.92 | 2300 | 6 | 6 |
3 | 2007.96 | 52 | 10.48 | 3576 | 6 | 6 |
4 | 1856.72 | 54 | 11.47 | 3363 | 6 | 6 |
5 | 512.12 | 54 | 13.32 | 1289 | 6 | 10 |
6 | 0.12 | 190 | 14.21 | 421 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.12 | 29 | 14.36 | 576 | 6 | 6 |
2 | 1160.48 | 7 | 10.74 | 2300 | 6 | 6 |
3 | 2004.52 | 52 | 10.43 | 3580 | 6 | 6 |
4 | 1695.64 | 54 | 11.67 | 3124 | 6 | 6 |
5 | 368.80 | 54 | 13.55 | 1061 | 6 | 11 |
6 | 0.08 | 191 | 14.22 | 418 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 29 | 14.29 | 576 | 6 | 6 |
2 | 1173.88 | 7 | 10.71 | 2352 | 6 | 6 |
3 | 2002.68 | 52 | 10.51 | 3572 | 6 | 6 |
4 | 1544.64 | 47 | 11.97 | 2878 | 6 | 6 |
5 | 628.76 | 47 | 13.17 | 1462 | 6 | 9 |
6 | 35.60 | 47 | 14.28 | 469 | 6 | 10 |
7 | 0.00 | 191 | 14.23 | 410 | 6 | 39 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.48 | 29 | 14.42 | 557 | 7 | 6 |
2 | 1156.88 | 7 | 10.89 | 2294 | 6 | 6 |
3 | 2009.44 | 52 | 10.47 | 3589 | 6 | 6 |
4 | 1562.88 | 47 | 11.92 | 2902 | 6 | 6 |
5 | 606.68 | 47 | 13.19 | 1427 | 6 | 9 |
6 | 39.44 | 47 | 14.27 | 475 | 6 | 10 |
7 | 0.08 | 191 | 14.23 | 412 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 29 | 14.36 | 596 | 7 | 6 |
2 | 1163.00 | 7 | 10.98 | 2326 | 6 | 6 |
3 | 2005.88 | 52 | 10.56 | 3591 | 6 | 6 |
4 | 1563.00 | 46 | 11.97 | 2907 | 6 | 6 |
5 | 486.36 | 46 | 13.39 | 1248 | 6 | 10 |
6 | 22.24 | 46 | 14.26 | 452 | 6 | 10 |
7 | -0.04 | 191 | 14.25 | 403 | 6 | 43 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 29 | 14.42 | 538 | 7 | 7 |
2 | 1156.00 | 7 | 11.02 | 2307 | 6 | 6 |
3 | 2005.56 | 52 | 10.53 | 3586 | 6 | 6 |
4 | 1696.64 | 46 | 11.85 | 3101 | 6 | 6 |
5 | 431.80 | 46 | 13.51 | 1152 | 6 | 9 |
6 | 37.72 | 46 | 14.26 | 477 | 6 | 10 |
7 | 0.00 | 191 | 14.23 | 405 | 6 | 39 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.08 | 29 | 14.36 | 538 | 7 | 7 |
2 | 1132.36 | 7 | 11.06 | 2269 | 6 | 6 |
3 | 2002.32 | 52 | 10.60 | 3585 | 6 | 6 |
4 | 1536.32 | 30 | 12.30 | 2895 | 6 | 6 |
5 | 829.48 | 30 | 13.08 | 1794 | 6 | 6 |
6 | 143.92 | 30 | 14.05 | 679 | 6 | 8 |
7 | 0.28 | 191 | 14.28 | 401 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.04 | 29 | 14.36 | 557 | 7 | 7 |
2 | 1157.20 | 7 | 11.13 | 2300 | 6 | 6 |
3 | 2001.04 | 52 | 10.61 | 3588 | 6 | 6 |
4 | 1666.88 | 30 | 12.17 | 3095 | 6 | 6 |
5 | 948.72 | 30 | 12.97 | 1953 | 6 | 6 |
6 | 122.36 | 30 | 14.16 | 629 | 6 | 7 |
7 | 27.92 | 30 | 14.34 | 451 | 6 | 8 |
8 | 0.12 | 191 | 14.28 | 399 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.40 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1154.72 | 7 | 11.02 | 2307 | 6 | 6 |
3 | 2001.40 | 52 | 10.62 | 3583 | 6 | 6 |
4 | 1679.92 | 30 | 12.13 | 3110 | 6 | 6 |
5 | 978.04 | 30 | 12.93 | 2001 | 6 | 6 |
6 | 134.08 | 30 | 14.11 | 651 | 6 | 7 |
7 | 30.48 | 30 | 14.34 | 453 | 6 | 8 |
8 | 0.04 | 190 | 14.27 | 396 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.32 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1146.20 | 7 | 11.04 | 2281 | 6 | 6 |
3 | 2014.84 | 52 | 10.60 | 3621 | 6 | 6 |
4 | 1722.00 | 30 | 12.06 | 3187 | 6 | 6 |
5 | 864.84 | 30 | 13.11 | 1821 | 6 | 6 |
6 | 158.60 | 30 | 14.05 | 701 | 6 | 8 |
7 | 34.68 | 30 | 14.29 | 468 | 6 | 8 |
8 | 0.08 | 191 | 14.25 | 408 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1134.16 | 7 | 10.92 | 2281 | 6 | 6 |
3 | 1995.72 | 52 | 10.63 | 3577 | 6 | 6 |
4 | 1541.56 | 30 | 12.33 | 2892 | 6 | 6 |
5 | 858.16 | 30 | 13.10 | 1813 | 6 | 6 |
6 | 146.00 | 30 | 14.09 | 669 | 6 | 8 |
7 | 33.40 | 30 | 14.34 | 456 | 6 | 8 |
8 | 0.04 | 191 | 14.27 | 400 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 29 | 14.36 | 576 | 7 | 7 |
2 | 1146.04 | 7 | 11.34 | 2262 | 6 | 6 |
3 | 1991.24 | 52 | 10.68 | 3571 | 6 | 6 |
4 | 1528.80 | 30 | 12.33 | 2866 | 6 | 6 |
5 | 862.52 | 30 | 13.08 | 1815 | 6 | 6 |
6 | 146.60 | 30 | 14.05 | 679 | 6 | 8 |
7 | 28.44 | 30 | 14.32 | 453 | 6 | 8 |
8 | 0.12 | 190 | 14.26 | 406 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 29 | 14.42 | 576 | 7 | 7 |
2 | 1155.00 | 7 | 11.04 | 2313 | 6 | 6 |
3 | 2000.76 | 52 | 10.72 | 3597 | 6 | 6 |
4 | 1549.20 | 30 | 12.33 | 2906 | 6 | 6 |
5 | 715.32 | 30 | 13.25 | 1605 | 6 | 7 |
6 | 109.12 | 30 | 14.18 | 597 | 6 | 7 |
7 | 0.20 | 191 | 14.29 | 396 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.68 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1136.12 | 7 | 11.08 | 2281 | 6 | 6 |
3 | 1954.16 | 52 | 10.78 | 3518 | 6 | 6 |
4 | 1662.56 | 30 | 12.25 | 3074 | 6 | 6 |
5 | 815.68 | 30 | 13.14 | 1759 | 6 | 6 |
6 | 137.96 | 30 | 14.11 | 656 | 6 | 8 |
7 | 28.12 | 30 | 14.33 | 451 | 6 | 8 |
8 | 0.04 | 190 | 14.26 | 407 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.20 | 29 | 14.29 | 576 | 7 | 7 |
2 | 1158.84 | 7 | 11.31 | 2300 | 6 | 6 |
3 | 2000.52 | 52 | 10.83 | 3581 | 6 | 6 |
4 | 1539.84 | 30 | 12.37 | 2909 | 6 | 6 |
5 | 710.96 | 30 | 13.29 | 1601 | 6 | 7 |
6 | 103.24 | 30 | 14.22 | 585 | 6 | 7 |
7 | 0.12 | 190 | 14.29 | 402 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.40 | 29 | 14.36 | 576 | 7 | 7 |
2 | 1153.00 | 7 | 11.07 | 2294 | 6 | 6 |
3 | 2002.08 | 52 | 10.78 | 3579 | 6 | 6 |
4 | 1850.56 | 30 | 12.03 | 3377 | 6 | 6 |
5 | 816.76 | 30 | 13.17 | 1754 | 6 | 6 |
6 | 141.88 | 30 | 14.10 | 666 | 6 | 8 |
7 | 27.16 | 30 | 14.37 | 453 | 6 | 8 |
8 | 0.04 | 191 | 14.25 | 406 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.20 | 29 | 14.42 | 576 | 7 | 7 |
2 | 1155.08 | 7 | 11.27 | 2288 | 6 | 6 |
3 | 1985.64 | 52 | 10.91 | 3543 | 6 | 6 |
4 | 1395.80 | 30 | 12.53 | 2685 | 6 | 6 |
5 | 754.52 | 30 | 13.30 | 1648 | 6 | 7 |
6 | 107.08 | 30 | 14.20 | 607 | 6 | 8 |
7 | 0.04 | 191 | 14.26 | 405 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1145.12 | 7 | 10.95 | 2287 | 6 | 6 |
3 | 2001.40 | 52 | 10.93 | 3570 | 6 | 6 |
4 | 1517.00 | 30 | 12.41 | 2856 | 6 | 6 |
5 | 714.72 | 30 | 13.28 | 1619 | 6 | 7 |
6 | 96.28 | 30 | 14.25 | 566 | 6 | 7 |
7 | 0.12 | 191 | 14.28 | 396 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.36 | 29 | 14.42 | 576 | 7 | 7 |
2 | 1152.16 | 7 | 11.08 | 2275 | 6 | 6 |
3 | 1993.40 | 50 | 10.97 | 3569 | 6 | 6 |
4 | 1673.96 | 30 | 12.30 | 3098 | 6 | 6 |
5 | 816.24 | 30 | 13.19 | 1741 | 6 | 6 |
6 | 134.76 | 30 | 14.12 | 659 | 6 | 8 |
7 | 13.52 | 30 | 14.40 | 424 | 6 | 8 |
8 | 0.12 | 191 | 14.22 | 404 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 29 | 14.36 | 557 | 7 | 7 |
2 | 1147.28 | 7 | 11.13 | 2307 | 6 | 6 |
3 | 2002.44 | 50 | 10.89 | 3598 | 6 | 6 |
4 | 1704.12 | 30 | 12.26 | 3151 | 6 | 6 |
5 | 842.60 | 30 | 13.19 | 1786 | 6 | 6 |
6 | 151.96 | 30 | 14.08 | 677 | 6 | 8 |
7 | 2.32 | 30 | 14.41 | 398 | 6 | 11 |
8 | 0.00 | 191 | 14.24 | 398 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.08 | 29 | 14.48 | 538 | 7 | 7 |
2 | 1152.64 | 7 | 11.12 | 2281 | 6 | 6 |
3 | 2002.32 | 50 | 11.01 | 3577 | 6 | 6 |
4 | 1397.24 | 30 | 12.65 | 2637 | 6 | 6 |
5 | 723.40 | 30 | 13.34 | 1605 | 6 | 7 |
6 | 105.36 | 30 | 14.23 | 587 | 6 | 7 |
7 | 0.12 | 191 | 14.30 | 392 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.72 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1150.52 | 7 | 11.10 | 2294 | 6 | 6 |
3 | 1999.00 | 50 | 11.02 | 3588 | 6 | 6 |
4 | 1684.72 | 30 | 12.36 | 3113 | 6 | 6 |
5 | 818.36 | 30 | 13.17 | 1756 | 6 | 6 |
6 | 137.44 | 30 | 14.12 | 653 | 6 | 8 |
7 | 0.08 | 190 | 14.28 | 395 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1160.40 | 7 | 11.08 | 2307 | 6 | 6 |
3 | 2000.32 | 50 | 11.03 | 3593 | 6 | 6 |
4 | 1678.44 | 30 | 12.33 | 3122 | 6 | 6 |
5 | 774.92 | 30 | 13.22 | 1687 | 6 | 7 |
6 | 124.64 | 30 | 14.16 | 634 | 6 | 8 |
7 | 0.08 | 190 | 14.28 | 391 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.04 | 29 | 14.42 | 576 | 7 | 7 |
2 | 1151.24 | 7 | 11.21 | 2288 | 6 | 6 |
3 | 2003.32 | 50 | 11.08 | 3593 | 6 | 6 |
4 | 1550.28 | 30 | 12.48 | 2901 | 6 | 6 |
5 | 726.00 | 30 | 13.29 | 1623 | 6 | 7 |
6 | 98.96 | 30 | 14.20 | 587 | 6 | 8 |
7 | 0.12 | 190 | 14.26 | 398 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.80 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1156.64 | 7 | 10.95 | 2307 | 6 | 6 |
3 | 2001.88 | 50 | 11.18 | 3600 | 6 | 6 |
4 | 1528.20 | 30 | 12.53 | 2860 | 6 | 6 |
5 | 668.28 | 30 | 13.38 | 1494 | 6 | 7 |
6 | 148.64 | 30 | 14.12 | 677 | 6 | 8 |
7 | 0.08 | 191 | 14.27 | 395 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.24 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1209.56 | 4 | 10.24 | 2403 | 6 | 6 |
3 | 2004.40 | 50 | 11.13 | 3596 | 6 | 6 |
4 | 1696.96 | 30 | 12.39 | 3138 | 6 | 6 |
5 | 836.32 | 30 | 13.22 | 1773 | 6 | 6 |
6 | 147.80 | 30 | 14.16 | 666 | 6 | 8 |
7 | 0.04 | 190 | 14.26 | 393 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.44 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1210.80 | 4 | 9.70 | 2403 | 6 | 6 |
3 | 2007.36 | 50 | 11.17 | 3595 | 6 | 6 |
4 | 1546.28 | 30 | 12.58 | 2872 | 6 | 6 |
5 | 724.12 | 30 | 13.36 | 1574 | 6 | 6 |
6 | 115.48 | 30 | 14.21 | 592 | 6 | 7 |
7 | 0.20 | 191 | 14.30 | 379 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 29 | 14.36 | 576 | 7 | 7 |
2 | 1195.20 | 5 | 9.70 | 2397 | 6 | 6 |
3 | 2002.04 | 50 | 11.18 | 3593 | 6 | 6 |
4 | 1703.80 | 30 | 12.44 | 3156 | 6 | 6 |
5 | 878.92 | 30 | 13.21 | 1834 | 6 | 6 |
6 | 182.96 | 30 | 14.09 | 726 | 6 | 8 |
7 | 0.92 | 190 | 14.26 | 395 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 29 | 14.55 | 519 | 7 | 7 |
2 | 1205.52 | 3 | 8.24 | 2393 | 6 | 6 |
3 | 2000.52 | 29 | 11.15 | 3612 | 6 | 6 |
4 | 1885.76 | 21 | 12.45 | 3435 | 6 | 6 |
5 | 1574.68 | 21 | 12.77 | 2950 | 6 | 6 |
6 | 907.84 | 21 | 13.25 | 1922 | 6 | 6 |
7 | 289.48 | 21 | 13.88 | 929 | 6 | 7 |
8 | 77.04 | 21 | 14.27 | 533 | 6 | 7 |
9 | 0.92 | 190 | 14.24 | 389 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.20 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1185.48 | 3 | 8.14 | 2326 | 6 | 6 |
3 | 2002.36 | 29 | 11.15 | 3626 | 6 | 6 |
4 | 1893.80 | 21 | 12.39 | 3493 | 6 | 6 |
5 | 1602.24 | 21 | 12.74 | 3006 | 6 | 6 |
6 | 1097.92 | 21 | 13.11 | 2193 | 6 | 6 |
7 | 301.48 | 21 | 13.88 | 937 | 6 | 7 |
8 | 92.48 | 21 | 14.29 | 546 | 6 | 6 |
9 | 0.16 | 190 | 14.28 | 378 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.28 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1187.24 | 3 | 7.92 | 2336 | 6 | 6 |
3 | 2004.16 | 29 | 11.10 | 3629 | 6 | 6 |
4 | 1891.88 | 21 | 12.47 | 3444 | 6 | 6 |
5 | 1755.96 | 21 | 12.63 | 3221 | 6 | 6 |
6 | 1091.28 | 21 | 13.13 | 2153 | 6 | 6 |
7 | 567.44 | 21 | 13.58 | 1354 | 6 | 7 |
8 | 113.36 | 21 | 14.22 | 584 | 6 | 7 |
9 | 12.84 | 21 | 14.44 | 401 | 6 | 7 |
10 | 0.12 | 191 | 14.20 | 393 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.92 | 29 | 14.48 | 538 | 7 | 6 |
2 | 1194.96 | 3 | 8.17 | 2326 | 6 | 6 |
3 | 2003.88 | 29 | 11.15 | 3608 | 6 | 6 |
4 | 1879.72 | 21 | 12.44 | 3435 | 6 | 6 |
5 | 1577.64 | 21 | 12.77 | 2980 | 6 | 6 |
6 | 1083.76 | 21 | 13.11 | 2179 | 6 | 6 |
7 | 421.04 | 21 | 13.73 | 1144 | 6 | 7 |
8 | 73.52 | 21 | 14.29 | 514 | 6 | 6 |
9 | 0.00 | 190 | 14.25 | 384 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.52 | 29 | 14.42 | 538 | 7 | 6 |
2 | 1200.48 | 3 | 7.60 | 2298 | 6 | 6 |
3 | 2005.04 | 29 | 11.14 | 3641 | 6 | 6 |
4 | 1894.52 | 21 | 12.49 | 3461 | 6 | 6 |
5 | 1458.96 | 21 | 12.88 | 2756 | 6 | 6 |
6 | 997.28 | 21 | 13.23 | 2040 | 6 | 6 |
7 | 335.52 | 21 | 13.88 | 993 | 6 | 7 |
8 | 94.16 | 21 | 14.31 | 550 | 6 | 7 |
9 | -0.04 | 190 | 14.26 | 378 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.48 | 29 | 14.36 | 557 | 7 | 7 |
2 | 1190.72 | 3 | 7.34 | 2278 | 6 | 6 |
3 | 2005.00 | 29 | 11.17 | 3622 | 6 | 6 |
4 | 1892.76 | 21 | 12.47 | 3448 | 6 | 6 |
5 | 1755.36 | 21 | 12.66 | 3236 | 6 | 6 |
6 | 1085.44 | 21 | 13.15 | 2161 | 6 | 6 |
7 | 419.40 | 21 | 13.79 | 1127 | 6 | 7 |
8 | 127.36 | 21 | 14.20 | 621 | 6 | 7 |
9 | 0.20 | 190 | 14.24 | 392 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.20 | 29 | 14.42 | 557 | 6 | 7 |
2 | 1195.52 | 3 | 7.34 | 2269 | 6 | 6 |
3 | 2002.84 | 29 | 11.17 | 3643 | 6 | 6 |
4 | 1898.44 | 21 | 12.50 | 3457 | 6 | 6 |
5 | 1598.68 | 21 | 12.79 | 3003 | 6 | 6 |
6 | 1257.88 | 21 | 13.07 | 2414 | 6 | 6 |
7 | 391.04 | 21 | 13.79 | 1072 | 6 | 7 |
8 | 110.92 | 21 | 14.20 | 595 | 6 | 7 |
9 | 0.00 | 191 | 14.25 | 386 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.76 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1211.76 | 3 | 7.57 | 2297 | 6 | 6 |
3 | 2001.64 | 29 | 11.14 | 3635 | 6 | 6 |
4 | 1879.36 | 21 | 12.48 | 3433 | 6 | 6 |
5 | 1741.44 | 21 | 12.64 | 3191 | 6 | 6 |
6 | 1068.28 | 21 | 13.22 | 2121 | 6 | 6 |
7 | 405.32 | 21 | 13.74 | 1117 | 6 | 7 |
8 | 118.72 | 21 | 14.22 | 606 | 6 | 7 |
9 | 0.16 | 191 | 14.25 | 392 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 29 | 14.48 | 538 | 7 | 7 |
2 | 1226.28 | 3 | 7.31 | 2288 | 6 | 6 |
3 | 2005.12 | 29 | 11.16 | 3628 | 6 | 6 |
4 | 1906.52 | 21 | 12.49 | 3469 | 6 | 6 |
5 | 1460.64 | 21 | 12.85 | 2777 | 6 | 6 |
6 | 989.72 | 21 | 13.26 | 2025 | 6 | 6 |
7 | 344.12 | 21 | 13.86 | 1008 | 6 | 7 |
8 | 103.04 | 21 | 14.25 | 567 | 6 | 7 |
9 | 0.04 | 190 | 14.28 | 378 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.76 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1204.76 | 3 | 7.22 | 2230 | 6 | 6 |
3 | 2006.64 | 29 | 11.11 | 3634 | 6 | 6 |
4 | 1891.88 | 21 | 12.53 | 3448 | 6 | 6 |
5 | 1594.80 | 21 | 12.85 | 2978 | 6 | 6 |
6 | 939.20 | 21 | 13.29 | 1956 | 6 | 6 |
7 | 302.40 | 21 | 13.90 | 937 | 6 | 7 |
8 | 87.96 | 21 | 14.35 | 529 | 6 | 7 |
9 | 0.12 | 190 | 14.27 | 379 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.68 | 29 | 14.36 | 557 | 7 | 7 |
2 | 1186.40 | 3 | 7.25 | 2230 | 6 | 6 |
3 | 2001.24 | 29 | 11.09 | 3618 | 6 | 6 |
4 | 1890.72 | 21 | 12.53 | 3437 | 6 | 6 |
5 | 1742.52 | 21 | 12.70 | 3221 | 6 | 6 |
6 | 1071.04 | 21 | 13.23 | 2144 | 6 | 6 |
7 | 408.36 | 21 | 13.82 | 1110 | 6 | 7 |
8 | 115.16 | 21 | 14.20 | 602 | 6 | 7 |
9 | 0.16 | 191 | 14.28 | 384 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.20 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1195.80 | 3 | 7.02 | 2259 | 6 | 6 |
3 | 2006.68 | 29 | 11.11 | 3611 | 6 | 6 |
4 | 1897.72 | 21 | 12.52 | 3459 | 6 | 6 |
5 | 1608.60 | 21 | 12.86 | 2982 | 6 | 6 |
6 | 975.44 | 21 | 13.27 | 1990 | 6 | 6 |
7 | 346.60 | 21 | 13.84 | 1021 | 6 | 7 |
8 | 100.72 | 21 | 14.27 | 567 | 6 | 7 |
9 | 0.04 | 191 | 14.26 | 387 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.32 | 29 | 14.48 | 557 | 7 | 7 |
2 | 1210.00 | 3 | 6.90 | 2249 | 6 | 6 |
3 | 2000.40 | 29 | 11.04 | 3630 | 6 | 6 |
4 | 1890.24 | 21 | 12.56 | 3426 | 6 | 6 |
5 | 1469.20 | 21 | 12.91 | 2785 | 6 | 6 |
6 | 1149.24 | 21 | 13.15 | 2277 | 6 | 6 |
7 | 335.32 | 21 | 13.87 | 1001 | 6 | 7 |
8 | 95.28 | 21 | 14.27 | 554 | 6 | 7 |
9 | 24.20 | 21 | 14.43 | 418 | 6 | 7 |
10 | 0.08 | 191 | 14.25 | 378 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 29 | 14.42 | 576 | 7 | 7 |
2 | 1212.04 | 3 | 7.12 | 2278 | 6 | 6 |
3 | 2001.04 | 29 | 11.03 | 3631 | 6 | 6 |
4 | 1902.20 | 21 | 12.50 | 3463 | 6 | 6 |
5 | 1761.48 | 21 | 12.74 | 3226 | 6 | 6 |
6 | 1104.72 | 21 | 13.23 | 2202 | 6 | 6 |
7 | 453.28 | 21 | 13.78 | 1185 | 6 | 7 |
8 | 86.00 | 21 | 14.32 | 533 | 6 | 6 |
9 | 8.72 | 21 | 14.47 | 390 | 6 | 7 |
10 | 0.12 | 191 | 14.24 | 380 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.56 | 29 | 14.55 | 538 | 7 | 7 |
2 | 1193.64 | 3 | 7.34 | 2307 | 6 | 6 |
3 | 2007.16 | 29 | 11.01 | 3652 | 6 | 6 |
4 | 1890.32 | 21 | 12.53 | 3431 | 6 | 6 |
5 | 1583.76 | 21 | 12.84 | 2967 | 6 | 6 |
6 | 953.76 | 21 | 13.34 | 1952 | 6 | 6 |
7 | 321.84 | 21 | 13.89 | 980 | 6 | 7 |
8 | 96.00 | 21 | 14.32 | 557 | 6 | 7 |
9 | 0.08 | 191 | 14.30 | 372 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.76 | 29 | 14.48 | 538 | 7 | 7 |
2 | 1195.32 | 3 | 7.09 | 2316 | 6 | 6 |
3 | 2005.64 | 29 | 11.07 | 3631 | 6 | 6 |
4 | 1882.84 | 21 | 12.49 | 3446 | 6 | 6 |
5 | 1439.48 | 21 | 12.92 | 2747 | 6 | 6 |
6 | 845.04 | 21 | 13.42 | 1805 | 6 | 6 |
7 | 369.32 | 21 | 13.88 | 1050 | 6 | 7 |
8 | 103.32 | 21 | 14.28 | 576 | 6 | 7 |
9 | 7.88 | 21 | 14.46 | 394 | 6 | 8 |
10 | 0.12 | 190 | 14.23 | 376 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.32 | 29 | 14.55 | 538 | 7 | 7 |
2 | 1196.04 | 3 | 7.41 | 2355 | 6 | 6 |
3 | 2001.08 | 29 | 11.07 | 3632 | 6 | 6 |
4 | 1889.24 | 21 | 12.53 | 3444 | 6 | 6 |
5 | 1590.96 | 21 | 12.86 | 2995 | 6 | 6 |
6 | 955.40 | 21 | 13.32 | 1967 | 6 | 6 |
7 | 333.12 | 21 | 13.92 | 986 | 6 | 7 |
8 | 106.36 | 21 | 14.34 | 563 | 6 | 7 |
9 | 0.16 | 190 | 14.29 | 380 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.76 | 29 | 14.42 | 557 | 7 | 7 |
2 | 1195.44 | 3 | 7.72 | 2336 | 6 | 6 |
3 | 2003.76 | 29 | 11.19 | 3602 | 6 | 6 |
4 | 1890.00 | 21 | 12.54 | 3435 | 6 | 6 |
5 | 1595.72 | 21 | 12.85 | 2976 | 6 | 6 |
6 | 934.20 | 21 | 13.34 | 1933 | 6 | 6 |
7 | 299.20 | 21 | 13.95 | 931 | 6 | 7 |
8 | 91.08 | 21 | 14.35 | 533 | 6 | 6 |
9 | 45.80 | 21 | 14.40 | 446 | 6 | 7 |
10 | 0.08 | 190 | 14.28 | 376 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 29 | 14.55 | 538 | 7 | 7 |
2 | 1201.56 | 3 | 8.78 | 2269 | 6 | 6 |
3 | 2004.16 | 29 | 11.24 | 3607 | 6 | 6 |
4 | 1887.40 | 21 | 12.53 | 3454 | 6 | 6 |
5 | 1741.32 | 21 | 12.71 | 3206 | 6 | 6 |
6 | 921.68 | 21 | 13.37 | 1907 | 6 | 6 |
7 | 296.64 | 21 | 13.98 | 918 | 6 | 7 |
8 | 84.40 | 21 | 14.35 | 523 | 6 | 6 |
9 | 43.72 | 21 | 14.43 | 448 | 6 | 7 |
10 | 0.20 | 191 | 14.27 | 386 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 29 | 14.55 | 538 | 7 | 7 |
2 | 1195.80 | 3 | 8.94 | 2336 | 6 | 6 |
3 | 2001.00 | 29 | 11.36 | 3593 | 6 | 6 |
4 | 1891.04 | 21 | 12.59 | 3429 | 6 | 6 |
5 | 1592.12 | 21 | 12.85 | 2967 | 6 | 6 |
6 | 955.48 | 21 | 13.31 | 1986 | 6 | 6 |
7 | 328.76 | 21 | 13.93 | 982 | 6 | 7 |
8 | 88.32 | 21 | 14.35 | 542 | 6 | 7 |
9 | 45.84 | 21 | 14.35 | 465 | 6 | 7 |
10 | 0.12 | 191 | 14.26 | 381 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.56 | 29 | 14.55 | 557 | 7 | 7 |
2 | 1197.44 | 3 | 9.32 | 2336 | 6 | 6 |
3 | 2005.96 | 29 | 11.41 | 3616 | 6 | 6 |
4 | 1894.64 | 21 | 12.57 | 3448 | 6 | 6 |
5 | 1440.44 | 21 | 12.95 | 2726 | 6 | 6 |
6 | 957.76 | 21 | 13.37 | 1952 | 6 | 6 |
7 | 313.64 | 21 | 13.96 | 950 | 6 | 7 |
8 | 84.52 | 21 | 14.32 | 527 | 6 | 7 |
9 | 45.32 | 21 | 14.39 | 452 | 6 | 7 |
10 | 0.08 | 191 | 14.27 | 360 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 29 | 14.55 | 538 | 7 | 7 |
2 | 1210.12 | 3 | 9.77 | 2355 | 6 | 6 |
3 | 2002.88 | 29 | 11.48 | 3594 | 6 | 6 |
4 | 1880.32 | 21 | 12.54 | 3457 | 6 | 6 |
5 | 1427.20 | 21 | 13.01 | 2715 | 6 | 6 |
6 | 950.16 | 21 | 13.37 | 1946 | 6 | 6 |
7 | 293.68 | 21 | 14.00 | 918 | 6 | 7 |
8 | 78.32 | 21 | 14.36 | 521 | 6 | 7 |
9 | 20.96 | 21 | 14.45 | 414 | 6 | 7 |
10 | 0.04 | 190 | 14.30 | 370 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.28 | 29 | 14.55 | 538 | 7 | 7 |
2 | 1201.48 | 3 | 10.34 | 2307 | 6 | 6 |
3 | 2003.60 | 29 | 11.50 | 3612 | 6 | 6 |
4 | 1889.92 | 21 | 12.57 | 3450 | 6 | 6 |
5 | 1585.60 | 21 | 12.91 | 2971 | 6 | 6 |
6 | 926.56 | 21 | 13.41 | 1918 | 6 | 6 |
7 | 281.76 | 21 | 14.03 | 888 | 6 | 7 |
8 | 84.72 | 21 | 14.37 | 523 | 6 | 7 |
9 | 44.28 | 21 | 14.42 | 442 | 6 | 7 |
10 | 0.08 | 190 | 14.30 | 361 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.76 | 29 | 14.55 | 538 | 7 | 7 |
2 | 1214.68 | 3 | 10.57 | 2393 | 6 | 6 |
3 | 2000.80 | 29 | 11.58 | 3594 | 6 | 6 |
4 | 1860.36 | 21 | 12.58 | 3414 | 6 | 6 |
5 | 1559.88 | 21 | 12.91 | 2929 | 6 | 6 |
6 | 914.80 | 21 | 13.44 | 1892 | 6 | 6 |
7 | 263.84 | 21 | 14.09 | 856 | 6 | 7 |
8 | 74.88 | 21 | 14.39 | 506 | 6 | 7 |
9 | 41.12 | 21 | 14.41 | 442 | 6 | 7 |
10 | 0.12 | 191 | 14.32 | 371 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.28 | 28 | 14.61 | 538 | 7 | 7 |
2 | 1205.80 | 3 | 10.82 | 2374 | 6 | 6 |
3 | 2001.72 | 29 | 11.68 | 3599 | 6 | 6 |
4 | 1882.68 | 21 | 12.67 | 3422 | 6 | 6 |
5 | 1575.64 | 21 | 12.92 | 2941 | 6 | 6 |
6 | 909.80 | 21 | 13.45 | 1884 | 6 | 6 |
7 | 417.96 | 21 | 13.88 | 1123 | 6 | 7 |
8 | 63.80 | 21 | 14.39 | 491 | 6 | 7 |
9 | 32.76 | 21 | 14.39 | 433 | 6 | 8 |
10 | 0.08 | 190 | 14.24 | 378 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.04 | 28 | 14.55 | 557 | 7 | 7 |
2 | 1196.12 | 3 | 10.79 | 2384 | 6 | 6 |
3 | 2000.44 | 29 | 11.62 | 3597 | 6 | 6 |
4 | 1884.12 | 21 | 12.65 | 3429 | 6 | 6 |
5 | 1434.40 | 21 | 13.01 | 2715 | 6 | 6 |
6 | 933.76 | 21 | 13.44 | 1916 | 6 | 6 |
7 | 430.08 | 21 | 13.88 | 1125 | 6 | 8 |
8 | 72.00 | 21 | 14.38 | 499 | 6 | 7 |
9 | 0.12 | 191 | 14.34 | 372 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 28 | 14.61 | 519 | 7 | 7 |
2 | 1204.24 | 3 | 11.14 | 2403 | 6 | 6 |
3 | 2005.32 | 29 | 11.73 | 3601 | 6 | 6 |
4 | 1876.16 | 21 | 12.66 | 3420 | 6 | 6 |
5 | 1574.40 | 21 | 12.96 | 2952 | 6 | 6 |
6 | 923.60 | 21 | 13.48 | 1888 | 6 | 6 |
7 | 277.20 | 21 | 14.05 | 886 | 6 | 7 |
8 | 77.16 | 21 | 14.42 | 502 | 6 | 7 |
9 | 38.72 | 21 | 14.42 | 437 | 6 | 7 |
10 | 0.04 | 191 | 14.28 | 379 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.76 | 28 | 14.42 | 557 | 7 | 6 |
2 | 1206.40 | 3 | 11.13 | 2393 | 6 | 6 |
3 | 2004.84 | 29 | 11.73 | 3592 | 6 | 6 |
4 | 1878.60 | 25 | 12.59 | 3416 | 6 | 6 |
5 | 1545.12 | 25 | 12.95 | 2907 | 6 | 6 |
6 | 998.52 | 25 | 13.40 | 2011 | 6 | 6 |
7 | 245.40 | 25 | 14.05 | 832 | 6 | 8 |
8 | 55.08 | 25 | 14.40 | 482 | 6 | 8 |
9 | 0.12 | 191 | 14.29 | 381 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.72 | 28 | 14.55 | 557 | 7 | 7 |
2 | 1197.16 | 3 | 11.84 | 2374 | 6 | 6 |
3 | 2005.36 | 29 | 11.78 | 3599 | 6 | 6 |
4 | 1897.60 | 25 | 12.59 | 3449 | 6 | 6 |
5 | 1737.04 | 25 | 12.81 | 3164 | 6 | 6 |
6 | 816.80 | 25 | 13.55 | 1730 | 6 | 6 |
7 | 256.36 | 25 | 14.09 | 845 | 6 | 8 |
8 | 50.56 | 25 | 14.41 | 461 | 6 | 8 |
9 | 0.12 | 191 | 14.28 | 381 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.08 | 28 | 14.61 | 538 | 7 | 7 |
2 | 2005.96 | 28 | 11.42 | 3663 | 7 | 6 |
3 | 1888.28 | 25 | 12.69 | 3436 | 6 | 6 |
4 | 1733.88 | 25 | 12.89 | 3174 | 6 | 6 |
5 | 1012.32 | 25 | 13.41 | 2043 | 6 | 6 |
6 | 299.80 | 25 | 13.95 | 940 | 6 | 8 |
7 | 63.52 | 25 | 14.41 | 489 | 6 | 8 |
8 | 0.04 | 210 | 14.26 | 386 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.60 | 28 | 14.61 | 538 | 7 | 7 |
2 | 2006.88 | 28 | 11.60 | 3604 | 6 | 6 |
3 | 1910.52 | 25 | 12.70 | 3472 | 6 | 6 |
4 | 1748.28 | 25 | 12.87 | 3203 | 6 | 6 |
5 | 1014.44 | 25 | 13.41 | 2028 | 6 | 6 |
6 | 296.40 | 25 | 14.04 | 922 | 6 | 8 |
7 | 65.76 | 25 | 14.43 | 484 | 6 | 8 |
8 | 0.08 | 211 | 14.30 | 377 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.12 | 28 | 14.55 | 538 | 7 | 6 |
2 | 2000.88 | 28 | 11.69 | 3617 | 6 | 6 |
3 | 1910.32 | 16 | 12.83 | 3475 | 6 | 6 |
4 | 1787.12 | 16 | 12.98 | 3268 | 6 | 6 |
5 | 1512.68 | 16 | 13.22 | 2831 | 6 | 6 |
6 | 1099.72 | 16 | 13.42 | 2202 | 6 | 6 |
7 | 546.96 | 16 | 13.86 | 1348 | 6 | 7 |
8 | 138.12 | 16 | 14.30 | 636 | 6 | 6 |
9 | 70.44 | 16 | 14.37 | 508 | 6 | 7 |
10 | 32.48 | 16 | 14.43 | 431 | 6 | 7 |
11 | 0.12 | 210 | 14.26 | 380 | 6 | 39 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.52 | 28 | 14.61 | 538 | 7 | 6 |
2 | 2004.72 | 28 | 11.88 | 3612 | 6 | 6 |
3 | 1917.60 | 16 | 12.87 | 3474 | 6 | 6 |
4 | 1809.44 | 16 | 13.00 | 3290 | 6 | 6 |
5 | 1685.80 | 16 | 13.07 | 3123 | 6 | 6 |
6 | 1109.84 | 16 | 13.47 | 2227 | 6 | 6 |
7 | 425.00 | 16 | 13.95 | 1153 | 6 | 7 |
8 | 161.40 | 16 | 14.27 | 686 | 6 | 7 |
9 | 78.16 | 16 | 14.40 | 524 | 6 | 7 |
10 | 37.80 | 16 | 14.42 | 442 | 6 | 7 |
11 | 0.08 | 210 | 14.27 | 378 | 6 | 39 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 28 | 14.55 | 557 | 7 | 7 |
2 | 2006.84 | 28 | 11.92 | 3604 | 7 | 6 |
3 | 1918.32 | 16 | 12.86 | 3480 | 6 | 6 |
4 | 1810.84 | 16 | 12.98 | 3320 | 6 | 6 |
5 | 1547.68 | 16 | 13.21 | 2900 | 6 | 6 |
6 | 1002.20 | 16 | 13.56 | 2029 | 6 | 6 |
7 | 457.28 | 16 | 13.92 | 1216 | 6 | 7 |
8 | 180.64 | 16 | 14.24 | 727 | 6 | 7 |
9 | 82.00 | 16 | 14.37 | 535 | 6 | 7 |
10 | 3.04 | 16 | 14.52 | 378 | 6 | 7 |
11 | 0.04 | 210 | 14.27 | 377 | 6 | 45 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.56 | 28 | 14.61 | 538 | 7 | 7 |
2 | 1132.92 | 2 | 12.00 | 2288 | 6 | 6 |
3 | 2002.32 | 29 | 12.03 | 3599 | 6 | 6 |
4 | 1910.48 | 16 | 12.82 | 3494 | 6 | 6 |
5 | 1789.36 | 16 | 12.99 | 3290 | 6 | 6 |
6 | 1372.84 | 16 | 13.31 | 2631 | 6 | 6 |
7 | 963.56 | 16 | 13.59 | 1961 | 6 | 6 |
8 | 536.20 | 16 | 13.87 | 1329 | 6 | 7 |
9 | 119.52 | 16 | 14.33 | 604 | 6 | 7 |
10 | 64.12 | 16 | 14.42 | 491 | 6 | 7 |
11 | 0.12 | 210 | 14.31 | 372 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.80 | 28 | 14.55 | 538 | 6 | 7 |
2 | 1115.48 | 2 | 11.94 | 2288 | 6 | 6 |
3 | 2002.84 | 29 | 12.10 | 3607 | 6 | 6 |
4 | 1900.08 | 16 | 12.88 | 3450 | 6 | 6 |
5 | 1782.00 | 16 | 13.00 | 3277 | 6 | 6 |
6 | 1650.32 | 16 | 13.09 | 3092 | 6 | 6 |
7 | 1081.16 | 16 | 13.53 | 2139 | 6 | 6 |
8 | 505.12 | 16 | 13.91 | 1252 | 6 | 7 |
9 | 114.44 | 16 | 14.38 | 584 | 6 | 6 |
10 | 67.04 | 16 | 14.45 | 488 | 6 | 7 |
11 | 0.04 | 210 | 14.33 | 367 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.44 | 28 | 14.61 | 538 | 6 | 6 |
2 | 1126.64 | 2 | 12.44 | 2269 | 6 | 6 |
3 | 2004.44 | 29 | 12.19 | 3617 | 6 | 6 |
4 | 1902.16 | 16 | 12.88 | 3477 | 6 | 6 |
5 | 1775.24 | 16 | 13.02 | 3279 | 6 | 6 |
6 | 1376.24 | 16 | 13.33 | 2626 | 6 | 6 |
7 | 966.12 | 16 | 13.59 | 1996 | 6 | 6 |
8 | 308.52 | 16 | 14.09 | 958 | 6 | 7 |
9 | 178.28 | 16 | 14.27 | 716 | 6 | 7 |
10 | 82.84 | 16 | 14.40 | 532 | 6 | 7 |
11 | 0.16 | 210 | 14.33 | 367 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.76 | 28 | 14.55 | 557 | 7 | 6 |
2 | 1109.28 | 2 | 12.38 | 2269 | 6 | 6 |
3 | 2002.84 | 29 | 12.15 | 3619 | 6 | 6 |
4 | 1906.40 | 16 | 12.86 | 3488 | 6 | 6 |
5 | 1791.12 | 16 | 13.00 | 3293 | 6 | 6 |
6 | 1386.96 | 16 | 13.31 | 2647 | 6 | 6 |
7 | 846.12 | 16 | 13.65 | 1834 | 6 | 6 |
8 | 425.52 | 16 | 14.01 | 1153 | 6 | 7 |
9 | 143.24 | 16 | 14.32 | 661 | 6 | 7 |
10 | 70.80 | 16 | 14.44 | 505 | 6 | 7 |
11 | 0.08 | 210 | 14.31 | 379 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.88 | 28 | 14.68 | 519 | 7 | 7 |
2 | 1127.48 | 2 | 12.31 | 2288 | 6 | 6 |
3 | 2009.12 | 29 | 12.27 | 3622 | 6 | 6 |
4 | 1917.96 | 16 | 12.87 | 3507 | 6 | 6 |
5 | 1788.00 | 16 | 13.02 | 3266 | 6 | 6 |
6 | 1510.40 | 16 | 13.26 | 2809 | 6 | 6 |
7 | 1074.92 | 16 | 13.55 | 2128 | 6 | 6 |
8 | 364.04 | 16 | 14.03 | 1059 | 6 | 7 |
9 | 118.20 | 16 | 14.36 | 604 | 6 | 6 |
10 | 68.44 | 16 | 14.44 | 505 | 6 | 7 |
11 | 0.04 | 210 | 14.33 | 380 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 28 | 14.55 | 538 | 7 | 7 |
2 | 1109.76 | 2 | 12.31 | 2250 | 6 | 6 |
3 | 2002.36 | 29 | 12.17 | 3604 | 6 | 6 |
4 | 1900.20 | 16 | 12.84 | 3469 | 6 | 6 |
5 | 1769.84 | 16 | 12.99 | 3255 | 6 | 6 |
6 | 1363.88 | 16 | 13.25 | 2639 | 6 | 6 |
7 | 945.44 | 16 | 13.60 | 1958 | 6 | 6 |
8 | 390.96 | 16 | 14.03 | 1093 | 6 | 7 |
9 | 124.32 | 16 | 14.42 | 612 | 6 | 6 |
10 | 69.52 | 16 | 14.45 | 502 | 6 | 7 |
11 | 0.08 | 210 | 14.34 | 368 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.68 | 28 | 14.68 | 538 | 7 | 7 |
2 | 1129.12 | 3 | 12.69 | 2278 | 6 | 6 |
3 | 2002.48 | 29 | 12.04 | 3599 | 6 | 6 |
4 | 1906.36 | 16 | 12.81 | 3455 | 6 | 6 |
5 | 1658.36 | 16 | 13.05 | 3101 | 6 | 6 |
6 | 1258.40 | 16 | 13.39 | 2436 | 6 | 6 |
7 | 847.32 | 16 | 13.64 | 1812 | 6 | 6 |
8 | 437.32 | 16 | 14.00 | 1175 | 6 | 7 |
9 | 99.04 | 16 | 14.45 | 562 | 6 | 6 |
10 | 52.96 | 16 | 14.49 | 469 | 6 | 7 |
11 | 0.08 | 211 | 14.36 | 369 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 28 | 14.68 | 538 | 7 | 7 |
2 | 1124.00 | 3 | 12.70 | 2269 | 6 | 6 |
3 | 2003.52 | 29 | 12.19 | 3626 | 6 | 6 |
4 | 1896.12 | 16 | 12.84 | 3455 | 6 | 6 |
5 | 1777.00 | 16 | 12.97 | 3279 | 6 | 6 |
6 | 1253.56 | 16 | 13.36 | 2458 | 6 | 6 |
7 | 844.48 | 16 | 13.70 | 1821 | 6 | 6 |
8 | 294.76 | 16 | 14.14 | 933 | 6 | 7 |
9 | 94.00 | 16 | 14.45 | 559 | 6 | 6 |
10 | 50.92 | 16 | 14.50 | 469 | 6 | 7 |
11 | 0.00 | 210 | 14.32 | 380 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 28 | 14.68 | 538 | 7 | 7 |
2 | 1122.76 | 3 | 12.73 | 2297 | 6 | 6 |
3 | 2003.00 | 29 | 12.29 | 3628 | 6 | 6 |
4 | 1907.08 | 16 | 12.86 | 3480 | 6 | 6 |
5 | 1784.12 | 16 | 12.98 | 3252 | 6 | 6 |
6 | 1353.92 | 16 | 13.33 | 2582 | 6 | 6 |
7 | 817.24 | 16 | 13.72 | 1738 | 6 | 6 |
8 | 277.32 | 16 | 14.18 | 903 | 6 | 7 |
9 | 80.40 | 16 | 14.46 | 527 | 6 | 6 |
10 | 42.80 | 16 | 14.45 | 452 | 6 | 7 |
11 | 4.56 | 16 | 14.54 | 384 | 6 | 7 |
12 | 0.00 | 210 | 14.30 | 371 | 6 | 43 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.92 | 28 | 14.68 | 538 | 7 | 7 |
2 | 1130.12 | 3 | 12.85 | 2278 | 6 | 6 |
3 | 2001.36 | 29 | 12.46 | 3616 | 6 | 6 |
4 | 1898.44 | 16 | 12.89 | 3452 | 6 | 6 |
5 | 1775.68 | 16 | 13.03 | 3274 | 6 | 6 |
6 | 1217.20 | 16 | 13.42 | 2406 | 6 | 6 |
7 | 821.48 | 16 | 13.74 | 1782 | 6 | 6 |
8 | 405.96 | 16 | 14.06 | 1120 | 6 | 7 |
9 | 75.44 | 16 | 14.45 | 535 | 6 | 6 |
10 | 39.72 | 16 | 14.45 | 458 | 6 | 7 |
11 | 0.12 | 210 | 14.33 | 378 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 28 | 14.74 | 519 | 7 | 7 |
2 | 1125.60 | 3 | 13.05 | 2307 | 6 | 6 |
3 | 2000.52 | 29 | 12.55 | 3613 | 6 | 6 |
4 | 1898.32 | 16 | 12.91 | 3475 | 6 | 6 |
5 | 1772.20 | 16 | 13.06 | 3246 | 6 | 6 |
6 | 1357.12 | 16 | 13.37 | 2595 | 6 | 6 |
7 | 684.24 | 16 | 13.83 | 1592 | 6 | 6 |
8 | 285.92 | 16 | 14.19 | 922 | 6 | 7 |
9 | 89.48 | 16 | 14.49 | 548 | 6 | 6 |
10 | 46.60 | 16 | 14.50 | 469 | 6 | 7 |
11 | 0.04 | 210 | 14.37 | 372 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.28 | 28 | 14.68 | 538 | 7 | 6 |
2 | 1122.48 | 3 | 13.30 | 2288 | 6 | 6 |
3 | 2003.12 | 29 | 12.71 | 3623 | 6 | 6 |
4 | 1890.88 | 16 | 13.00 | 3444 | 6 | 6 |
5 | 1768.80 | 16 | 13.11 | 3263 | 6 | 6 |
6 | 1228.12 | 16 | 13.49 | 2428 | 6 | 6 |
7 | 799.52 | 16 | 13.81 | 1702 | 6 | 6 |
8 | 259.04 | 16 | 14.23 | 881 | 6 | 7 |
9 | 81.36 | 16 | 14.53 | 527 | 6 | 6 |
10 | 46.96 | 16 | 14.52 | 469 | 6 | 7 |
11 | 11.08 | 16 | 14.56 | 405 | 6 | 7 |
12 | 0.08 | 210 | 14.33 | 378 | 6 | 39 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.60 | 28 | 14.74 | 557 | 7 | 7 |
2 | 2004.88 | 29 | 13.04 | 3638 | 6 | 6 |
3 | 1927.76 | 16 | 13.04 | 3540 | 6 | 6 |
4 | 1833.64 | 16 | 13.12 | 3364 | 6 | 6 |
5 | 1409.00 | 16 | 13.47 | 2683 | 6 | 6 |
6 | 972.36 | 16 | 13.70 | 2027 | 6 | 6 |
7 | 442.56 | 16 | 14.09 | 1194 | 6 | 7 |
8 | 120.96 | 16 | 14.44 | 634 | 6 | 7 |
9 | 62.84 | 16 | 14.51 | 510 | 6 | 7 |
10 | 0.08 | 190 | 14.35 | 393 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.20 | 28 | 14.74 | 538 | 7 | 7 |
2 | 2003.44 | 29 | 13.03 | 3655 | 7 | 6 |
3 | 1928.36 | 16 | 13.14 | 3494 | 6 | 6 |
4 | 1833.44 | 16 | 13.18 | 3342 | 6 | 6 |
5 | 1401.36 | 16 | 13.50 | 2661 | 6 | 6 |
6 | 781.96 | 16 | 13.89 | 1694 | 6 | 6 |
7 | 366.76 | 16 | 14.17 | 1051 | 6 | 7 |
8 | 89.36 | 16 | 14.53 | 559 | 6 | 6 |
9 | 48.96 | 16 | 14.52 | 483 | 6 | 7 |
10 | 0.08 | 191 | 14.38 | 385 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.44 | 28 | 14.68 | 557 | 7 | 6 |
2 | 2002.20 | 29 | 13.06 | 3646 | 6 | 6 |
3 | 1921.48 | 16 | 13.15 | 3513 | 6 | 6 |
4 | 1625.84 | 16 | 13.36 | 3057 | 6 | 6 |
5 | 1422.72 | 16 | 13.44 | 2727 | 6 | 6 |
6 | 895.76 | 16 | 13.82 | 1873 | 6 | 6 |
7 | 566.36 | 16 | 14.01 | 1436 | 6 | 7 |
8 | 122.80 | 16 | 14.48 | 647 | 6 | 7 |
9 | 67.36 | 16 | 14.53 | 538 | 6 | 7 |
10 | 0.12 | 190 | 14.37 | 399 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.80 | 28 | 14.74 | 576 | 7 | 7 |
2 | 2006.92 | 29 | 13.10 | 3614 | 6 | 6 |
3 | 1938.40 | 16 | 13.14 | 3505 | 6 | 6 |
4 | 1846.72 | 16 | 13.21 | 3395 | 6 | 6 |
5 | 1515.36 | 16 | 13.46 | 2873 | 6 | 6 |
6 | 1066.24 | 16 | 13.73 | 2147 | 6 | 6 |
7 | 404.96 | 16 | 14.15 | 1145 | 6 | 7 |
8 | 105.56 | 16 | 14.52 | 609 | 6 | 6 |
9 | 58.84 | 16 | 14.57 | 505 | 6 | 7 |
10 | 0.12 | 191 | 14.38 | 398 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.88 | 28 | 14.80 | 500 | 7 | 7 |
2 | 2004.64 | 29 | 13.14 | 3598 | 7 | 6 |
3 | 1935.72 | 16 | 13.18 | 3502 | 6 | 6 |
4 | 1839.92 | 16 | 13.26 | 3345 | 6 | 6 |
5 | 1321.12 | 16 | 13.60 | 2510 | 6 | 6 |
6 | 1020.28 | 16 | 13.78 | 2038 | 6 | 6 |
7 | 369.84 | 16 | 14.23 | 1027 | 6 | 7 |
8 | 91.76 | 16 | 14.57 | 529 | 6 | 6 |
9 | 53.00 | 16 | 14.57 | 461 | 6 | 7 |
10 | 0.16 | 191 | 14.43 | 360 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.20 | 28 | 14.80 | 480 | 7 | 7 |
2 | 2001.64 | 29 | 13.15 | 3589 | 7 | 6 |
3 | 1915.60 | 15 | 13.24 | 3490 | 6 | 6 |
4 | 1721.92 | 15 | 13.40 | 3195 | 6 | 6 |
5 | 1321.76 | 15 | 13.66 | 2518 | 6 | 6 |
6 | 908.56 | 15 | 13.90 | 1861 | 6 | 6 |
7 | 599.52 | 15 | 14.10 | 1384 | 6 | 6 |
8 | 182.00 | 16 | 14.46 | 700 | 6 | 7 |
9 | 87.16 | 16 | 14.57 | 519 | 6 | 7 |
10 | 42.36 | 15 | 14.61 | 432 | 6 | 7 |
11 | 0.00 | 191 | 14.39 | 346 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.68 | 27 | 14.68 | 500 | 7 | 7 |
2 | 1043.88 | 1 | 14.23 | 2134 | 6 | 6 |
3 | 2006.00 | 29 | 13.17 | 3596 | 6 | 6 |
4 | 1925.76 | 16 | 13.21 | 3480 | 6 | 6 |
5 | 1628.60 | 16 | 13.44 | 3024 | 6 | 6 |
6 | 1210.52 | 16 | 13.69 | 2342 | 6 | 6 |
7 | 791.60 | 16 | 13.95 | 1691 | 6 | 6 |
8 | 363.80 | 16 | 14.27 | 1032 | 6 | 7 |
9 | 87.56 | 16 | 14.56 | 524 | 6 | 7 |
10 | 48.76 | 16 | 14.59 | 447 | 6 | 7 |
11 | 5.92 | 16 | 14.64 | 367 | 6 | 7 |
12 | 0.04 | 190 | 14.41 | 341 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.60 | 27 | 14.80 | 500 | 6 | 6 |
2 | 2008.12 | 29 | 13.22 | 3600 | 6 | 6 |
3 | 1934.20 | 16 | 13.19 | 3516 | 6 | 6 |
4 | 1732.20 | 16 | 13.40 | 3180 | 6 | 6 |
5 | 1221.12 | 16 | 13.71 | 2378 | 6 | 6 |
6 | 808.40 | 16 | 13.99 | 1727 | 6 | 6 |
7 | 375.48 | 16 | 14.23 | 1068 | 6 | 8 |
8 | 81.64 | 16 | 14.58 | 524 | 6 | 7 |
9 | 45.68 | 16 | 14.61 | 442 | 6 | 7 |
10 | 0.08 | 190 | 14.44 | 351 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.60 | 27 | 14.80 | 500 | 7 | 6 |
2 | 2002.76 | 29 | 13.23 | 3588 | 6 | 6 |
3 | 1916.36 | 16 | 13.24 | 3466 | 6 | 6 |
4 | 1727.12 | 16 | 13.41 | 3186 | 6 | 6 |
5 | 1422.52 | 16 | 13.60 | 2686 | 6 | 6 |
6 | 988.00 | 16 | 13.84 | 2007 | 6 | 6 |
7 | 425.20 | 16 | 14.23 | 1123 | 6 | 8 |
8 | 65.80 | 16 | 14.65 | 471 | 6 | 7 |
9 | 39.20 | 16 | 14.62 | 420 | 6 | 7 |
10 | 0.16 | 191 | 14.45 | 336 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 27 | 14.80 | 500 | 6 | 6 |
2 | 2004.48 | 29 | 13.27 | 3595 | 6 | 6 |
3 | 1923.12 | 16 | 13.25 | 3447 | 6 | 6 |
4 | 1830.64 | 16 | 13.32 | 3307 | 6 | 6 |
5 | 1418.80 | 16 | 13.62 | 2650 | 6 | 6 |
6 | 859.12 | 16 | 13.95 | 1755 | 6 | 6 |
7 | 315.20 | 16 | 14.33 | 936 | 6 | 8 |
8 | 67.68 | 16 | 14.65 | 483 | 6 | 7 |
9 | 37.20 | 16 | 14.64 | 414 | 6 | 7 |
10 | 0.04 | 190 | 14.41 | 338 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 27 | 14.74 | 500 | 7 | 6 |
2 | 2006.08 | 29 | 13.28 | 3601 | 6 | 6 |
3 | 1926.56 | 16 | 13.26 | 3480 | 6 | 6 |
4 | 1727.20 | 16 | 13.41 | 3194 | 6 | 6 |
5 | 1209.68 | 16 | 13.73 | 2345 | 6 | 6 |
6 | 894.32 | 16 | 13.93 | 1862 | 6 | 6 |
7 | 252.68 | 16 | 14.39 | 834 | 6 | 7 |
8 | 75.24 | 16 | 14.62 | 496 | 6 | 7 |
9 | 38.56 | 16 | 14.62 | 428 | 6 | 7 |
10 | 0.20 | 190 | 14.40 | 343 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.44 | 27 | 14.74 | 500 | 6 | 6 |
2 | 2002.28 | 29 | 13.30 | 3582 | 6 | 6 |
3 | 1920.80 | 16 | 13.26 | 3458 | 6 | 6 |
4 | 1601.60 | 16 | 13.47 | 2980 | 6 | 6 |
5 | 1193.84 | 16 | 13.78 | 2293 | 6 | 6 |
6 | 673.68 | 16 | 14.08 | 1516 | 6 | 6 |
7 | 244.88 | 16 | 14.41 | 820 | 6 | 8 |
8 | 76.56 | 16 | 14.64 | 494 | 6 | 7 |
9 | 41.44 | 16 | 14.65 | 431 | 6 | 8 |
10 | 0.00 | 190 | 14.42 | 338 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.00 | 27 | 14.74 | 500 | 6 | 6 |
2 | 2007.44 | 29 | 13.29 | 3596 | 6 | 6 |
3 | 1926.60 | 16 | 13.28 | 3444 | 6 | 6 |
4 | 1729.76 | 16 | 13.40 | 3150 | 6 | 6 |
5 | 1218.96 | 16 | 13.76 | 2331 | 6 | 6 |
6 | 908.52 | 16 | 13.93 | 1856 | 6 | 6 |
7 | 274.32 | 16 | 14.40 | 878 | 6 | 8 |
8 | 84.24 | 16 | 14.62 | 524 | 6 | 7 |
9 | 40.12 | 16 | 14.64 | 433 | 6 | 7 |
10 | 0.12 | 191 | 14.44 | 343 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.72 | 26 | 14.80 | 480 | 6 | 6 |
2 | 2003.36 | 29 | 13.28 | 3589 | 6 | 6 |
3 | 1923.24 | 16 | 13.26 | 3441 | 6 | 6 |
4 | 1829.76 | 16 | 13.30 | 3329 | 6 | 6 |
5 | 1296.00 | 16 | 13.68 | 2494 | 6 | 6 |
6 | 1093.16 | 16 | 13.80 | 2134 | 6 | 6 |
7 | 415.00 | 16 | 14.26 | 1106 | 6 | 8 |
8 | 89.68 | 16 | 14.60 | 524 | 6 | 7 |
9 | 45.32 | 16 | 14.62 | 444 | 6 | 8 |
10 | 0.72 | 190 | 14.40 | 345 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.92 | 26 | 14.74 | 500 | 6 | 6 |
2 | 2003.32 | 29 | 13.28 | 3593 | 6 | 6 |
3 | 1918.68 | 16 | 13.24 | 3458 | 6 | 6 |
4 | 1712.16 | 16 | 13.42 | 3150 | 6 | 6 |
5 | 1093.20 | 16 | 13.83 | 2139 | 6 | 6 |
6 | 776.92 | 16 | 13.97 | 1681 | 6 | 6 |
7 | 255.60 | 16 | 14.40 | 837 | 6 | 8 |
8 | 77.76 | 16 | 14.64 | 505 | 6 | 7 |
9 | 41.04 | 16 | 14.63 | 433 | 6 | 8 |
10 | 0.16 | 190 | 14.45 | 339 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 26 | 14.80 | 480 | 7 | 6 |
2 | 2002.16 | 29 | 13.27 | 3580 | 6 | 6 |
3 | 1924.88 | 16 | 13.21 | 3466 | 6 | 6 |
4 | 1728.00 | 16 | 13.42 | 3147 | 6 | 6 |
5 | 1410.32 | 16 | 13.63 | 2637 | 6 | 6 |
6 | 861.12 | 16 | 13.96 | 1809 | 6 | 6 |
7 | 222.08 | 16 | 14.44 | 777 | 6 | 7 |
8 | 73.68 | 16 | 14.66 | 485 | 6 | 7 |
9 | 38.20 | 16 | 14.65 | 423 | 6 | 7 |
10 | 0.08 | 191 | 14.44 | 337 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 26 | 14.74 | 500 | 6 | 6 |
2 | 2005.88 | 29 | 13.27 | 3582 | 6 | 6 |
3 | 1928.88 | 16 | 13.23 | 3477 | 6 | 6 |
4 | 1830.28 | 16 | 13.29 | 3312 | 6 | 6 |
5 | 1284.84 | 16 | 13.68 | 2452 | 6 | 6 |
6 | 874.72 | 16 | 13.95 | 1818 | 6 | 6 |
7 | 442.52 | 16 | 14.27 | 1136 | 6 | 8 |
8 | 67.32 | 16 | 14.65 | 485 | 6 | 7 |
9 | 37.52 | 16 | 14.66 | 420 | 6 | 7 |
10 | 0.08 | 190 | 14.45 | 336 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.56 | 26 | 14.80 | 480 | 6 | 6 |
2 | 2014.52 | 29 | 13.21 | 3612 | 6 | 6 |
3 | 1940.84 | 15 | 13.28 | 3480 | 6 | 6 |
4 | 1845.92 | 15 | 13.34 | 3329 | 6 | 6 |
5 | 1313.00 | 15 | 13.72 | 2499 | 6 | 6 |
6 | 923.20 | 15 | 13.94 | 1897 | 6 | 6 |
7 | 501.20 | 15 | 14.25 | 1243 | 6 | 7 |
8 | 98.76 | 15 | 14.64 | 541 | 6 | 7 |
9 | 56.64 | 15 | 14.67 | 454 | 6 | 7 |
10 | 28.72 | 15 | 14.68 | 403 | 6 | 7 |
11 | 0.04 | 191 | 14.45 | 336 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 26 | 14.80 | 480 | 6 | 6 |
2 | 2002.20 | 29 | 13.21 | 3586 | 6 | 6 |
3 | 1917.28 | 16 | 13.19 | 3458 | 6 | 6 |
4 | 1821.36 | 16 | 13.30 | 3301 | 6 | 6 |
5 | 1388.44 | 16 | 13.62 | 2623 | 6 | 6 |
6 | 944.36 | 16 | 13.92 | 1900 | 6 | 6 |
7 | 317.72 | 16 | 14.37 | 939 | 6 | 8 |
8 | 66.80 | 16 | 14.67 | 482 | 6 | 7 |
9 | 39.20 | 16 | 14.66 | 425 | 6 | 8 |
10 | 0.20 | 191 | 14.45 | 339 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.08 | 26 | 14.80 | 500 | 7 | 6 |
2 | 2002.80 | 29 | 13.21 | 3591 | 6 | 6 |
3 | 1926.40 | 16 | 13.25 | 3439 | 6 | 6 |
4 | 1831.48 | 16 | 13.31 | 3307 | 6 | 6 |
5 | 1269.12 | 16 | 13.69 | 2444 | 6 | 6 |
6 | 640.56 | 16 | 14.08 | 1485 | 6 | 6 |
7 | 238.08 | 16 | 14.43 | 812 | 6 | 7 |
8 | 69.04 | 16 | 14.66 | 482 | 6 | 7 |
9 | 36.84 | 16 | 14.66 | 428 | 6 | 7 |
10 | 17.08 | 16 | 14.65 | 381 | 6 | 8 |
11 | 0.08 | 190 | 14.41 | 343 | 6 | 40 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.40 | 26 | 14.80 | 480 | 6 | 6 |
2 | 2020.28 | 29 | 13.20 | 3616 | 6 | 6 |
3 | 1949.36 | 16 | 13.20 | 3510 | 6 | 6 |
4 | 1642.04 | 16 | 13.46 | 3032 | 6 | 6 |
5 | 1120.00 | 16 | 13.78 | 2183 | 6 | 6 |
6 | 804.88 | 16 | 14.01 | 1716 | 6 | 6 |
7 | 269.96 | 16 | 14.43 | 859 | 6 | 7 |
8 | 84.68 | 16 | 14.64 | 516 | 6 | 7 |
9 | 41.68 | 16 | 14.69 | 433 | 6 | 8 |
10 | 0.12 | 190 | 14.47 | 343 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.84 | 26 | 14.80 | 500 | 6 | 6 |
2 | 2004.80 | 29 | 13.20 | 3594 | 6 | 6 |
3 | 1925.64 | 16 | 13.19 | 3480 | 6 | 6 |
4 | 1620.00 | 16 | 13.46 | 2996 | 6 | 6 |
5 | 1523.08 | 16 | 13.51 | 2804 | 6 | 6 |
6 | 856.80 | 16 | 13.97 | 1785 | 6 | 6 |
7 | 410.48 | 16 | 14.26 | 1104 | 6 | 8 |
8 | 92.20 | 16 | 14.65 | 540 | 6 | 7 |
9 | 47.00 | 16 | 14.69 | 447 | 6 | 8 |
10 | 0.16 | 190 | 14.48 | 343 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 26 | 14.80 | 500 | 6 | 6 |
2 | 2004.76 | 29 | 13.22 | 3598 | 6 | 6 |
3 | 1926.68 | 16 | 13.24 | 3466 | 6 | 6 |
4 | 1833.92 | 16 | 13.28 | 3323 | 6 | 6 |
5 | 1399.20 | 16 | 13.59 | 2639 | 6 | 6 |
6 | 869.20 | 16 | 13.98 | 1799 | 6 | 6 |
7 | 427.64 | 16 | 14.29 | 1112 | 6 | 8 |
8 | 99.36 | 16 | 14.63 | 548 | 6 | 7 |
9 | 27.64 | 16 | 14.74 | 403 | 6 | 8 |
10 | 13.00 | 16 | 14.71 | 370 | 6 | 8 |
11 | 0.08 | 190 | 14.43 | 344 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 26 | 14.80 | 500 | 6 | 6 |
2 | 2002.64 | 29 | 13.21 | 3595 | 6 | 6 |
3 | 1915.40 | 16 | 13.21 | 3458 | 6 | 6 |
4 | 1817.00 | 16 | 13.32 | 3301 | 6 | 6 |
5 | 1307.08 | 16 | 13.66 | 2496 | 6 | 6 |
6 | 771.44 | 16 | 14.03 | 1689 | 6 | 6 |
7 | 334.96 | 16 | 14.35 | 966 | 6 | 8 |
8 | 119.88 | 16 | 14.61 | 598 | 6 | 8 |
9 | 32.44 | 16 | 14.74 | 422 | 6 | 8 |
10 | -0.08 | 191 | 14.45 | 350 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 26 | 14.80 | 500 | 6 | 6 |
2 | 2004.88 | 29 | 13.24 | 3593 | 6 | 6 |
3 | 1923.04 | 16 | 13.24 | 3461 | 6 | 6 |
4 | 1731.00 | 16 | 13.42 | 3175 | 6 | 6 |
5 | 1135.28 | 16 | 13.81 | 2225 | 6 | 6 |
6 | 625.44 | 16 | 14.14 | 1452 | 6 | 6 |
7 | 305.64 | 16 | 14.37 | 944 | 6 | 8 |
8 | 62.44 | 16 | 14.71 | 485 | 6 | 7 |
9 | 34.92 | 16 | 14.72 | 417 | 6 | 7 |
10 | 0.12 | 190 | 14.48 | 344 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.00 | 26 | 14.80 | 500 | 6 | 6 |
2 | 2002.84 | 29 | 13.25 | 3578 | 6 | 6 |
3 | 1929.60 | 16 | 13.27 | 3491 | 6 | 6 |
4 | 1731.36 | 16 | 13.39 | 3186 | 6 | 6 |
5 | 1432.04 | 16 | 13.61 | 2691 | 6 | 6 |
6 | 773.76 | 16 | 14.03 | 1667 | 6 | 6 |
7 | 240.16 | 16 | 14.43 | 834 | 6 | 7 |
8 | 79.20 | 16 | 14.68 | 519 | 6 | 7 |
9 | 42.08 | 16 | 14.73 | 442 | 6 | 7 |
10 | -0.04 | 190 | 14.48 | 349 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 26 | 14.80 | 500 | 6 | 6 |
2 | 2003.52 | 29 | 13.23 | 3602 | 6 | 6 |
3 | 1921.52 | 16 | 13.22 | 3488 | 6 | 6 |
4 | 1822.96 | 16 | 13.33 | 3301 | 6 | 6 |
5 | 1185.92 | 16 | 13.75 | 2315 | 6 | 6 |
6 | 774.80 | 16 | 14.00 | 1678 | 6 | 6 |
7 | 258.40 | 16 | 14.46 | 848 | 6 | 7 |
8 | 78.84 | 16 | 14.71 | 516 | 6 | 7 |
9 | 45.32 | 16 | 14.73 | 444 | 6 | 8 |
10 | 0.08 | 191 | 14.53 | 345 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.12 | 26 | 14.80 | 519 | 7 | 6 |
2 | 2001.12 | 29 | 13.28 | 3602 | 6 | 6 |
3 | 1923.12 | 16 | 13.28 | 3447 | 6 | 6 |
4 | 1829.76 | 16 | 13.34 | 3296 | 6 | 6 |
5 | 1296.40 | 16 | 13.68 | 2485 | 6 | 6 |
6 | 877.24 | 16 | 13.95 | 1848 | 6 | 6 |
7 | 320.52 | 16 | 14.38 | 963 | 6 | 8 |
8 | 110.12 | 16 | 14.65 | 576 | 6 | 7 |
9 | 25.08 | 16 | 14.78 | 411 | 6 | 7 |
10 | 0.16 | 190 | 14.49 | 348 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.72 | 26 | 14.80 | 519 | 6 | 6 |
2 | 2005.28 | 70 | 12.83 | 3583 | 6 | 6 |
3 | 1064.44 | 25 | 13.71 | 2122 | 6 | 6 |
4 | 199.24 | 25 | 14.49 | 736 | 6 | 7 |
5 | 58.20 | 25 | 14.73 | 464 | 6 | 7 |
6 | 0.08 | 200 | 14.51 | 346 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 26 | 14.87 | 519 | 6 | 6 |
2 | 2007.00 | 70 | 12.85 | 3586 | 6 | 6 |
3 | 1024.36 | 25 | 13.73 | 2064 | 6 | 6 |
4 | 294.12 | 25 | 14.33 | 913 | 6 | 9 |
5 | 63.88 | 25 | 14.70 | 484 | 6 | 8 |
6 | 0.08 | 201 | 14.49 | 350 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 26 | 14.80 | 519 | 7 | 6 |
2 | 2001.52 | 70 | 12.87 | 3571 | 6 | 6 |
3 | 1045.84 | 25 | 13.73 | 2087 | 6 | 6 |
4 | 320.64 | 25 | 14.31 | 963 | 6 | 9 |
5 | 63.08 | 25 | 14.70 | 484 | 6 | 8 |
6 | 0.04 | 200 | 14.48 | 356 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.16 | 26 | 14.80 | 519 | 6 | 6 |
2 | 2004.20 | 70 | 12.88 | 3585 | 6 | 6 |
3 | 1232.88 | 25 | 13.61 | 2368 | 6 | 6 |
4 | 267.92 | 25 | 14.40 | 874 | 6 | 8 |
5 | 65.16 | 25 | 14.69 | 488 | 6 | 8 |
6 | 0.12 | 201 | 14.51 | 350 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.52 | 26 | 14.87 | 519 | 6 | 6 |
2 | 2004.00 | 70 | 12.89 | 3578 | 6 | 6 |
3 | 1024.48 | 25 | 13.74 | 2065 | 6 | 6 |
4 | 318.76 | 25 | 14.31 | 966 | 6 | 9 |
5 | 70.64 | 25 | 14.70 | 505 | 6 | 8 |
6 | 0.12 | 200 | 14.49 | 361 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 25 | 14.87 | 519 | 6 | 6 |
2 | 1025.28 | 1 | 14.55 | 2173 | 6 | 6 |
3 | 2004.96 | 70 | 12.90 | 3574 | 6 | 6 |
4 | 1025.60 | 25 | 13.73 | 2051 | 6 | 6 |
5 | 297.80 | 25 | 14.33 | 936 | 6 | 9 |
6 | 65.88 | 25 | 14.70 | 499 | 6 | 8 |
7 | 0.12 | 201 | 14.48 | 363 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 27 | 14.80 | 519 | 6 | 6 |
2 | 960.52 | -1 | 14.80 | 519 | 6 | 6 |
3 | 2002.24 | 70 | 12.89 | 3576 | 6 | 6 |
4 | 1023.24 | 25 | 13.73 | 2055 | 6 | 6 |
5 | 294.76 | 25 | 14.34 | 909 | 6 | 8 |
6 | 65.52 | 25 | 14.72 | 494 | 6 | 7 |
7 | 0.12 | 201 | 14.48 | 362 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 21 | 14.87 | 519 | 6 | 6 |
2 | 1043.92 | 6 | 14.48 | 2134 | 6 | 6 |
3 | 2001.52 | 70 | 12.88 | 3578 | 6 | 6 |
4 | 987.92 | 25 | 13.71 | 2011 | 6 | 6 |
5 | 296.44 | 25 | 14.33 | 918 | 6 | 8 |
6 | 59.24 | 25 | 14.71 | 490 | 6 | 8 |
7 | 0.12 | 201 | 14.46 | 361 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 30 | 14.80 | 519 | 6 | 6 |
2 | 772.92 | -4 | 14.80 | 519 | 6 | 6 |
3 | 888.24 | -2 | 14.80 | 519 | 6 | 6 |
4 | 2000.80 | 70 | 12.85 | 3579 | 6 | 6 |
5 | 1000.40 | 25 | 13.68 | 2013 | 6 | 6 |
6 | 284.36 | 25 | 14.33 | 922 | 6 | 8 |
7 | 60.52 | 24 | 14.68 | 499 | 6 | 8 |
8 | 0.12 | 201 | 14.45 | 366 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.48 | 25 | 14.80 | 519 | 6 | 6 |
2 | 1509.96 | 70 | 13.19 | 2843 | 6 | 6 |
3 | 797.64 | 25 | 13.83 | 1726 | 6 | 6 |
4 | 146.92 | 25 | 14.55 | 657 | 6 | 7 |
5 | 35.00 | 25 | 14.76 | 445 | 6 | 7 |
6 | 0.08 | 201 | 14.43 | 368 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 23 | 14.80 | 519 | 6 | 6 |
2 | 1041.80 | 1 | 14.61 | 2153 | 6 | 6 |
3 | 1502.64 | 70 | 13.17 | 2830 | 6 | 6 |
4 | 801.16 | 25 | 13.80 | 1730 | 6 | 6 |
5 | 146.20 | 25 | 14.49 | 661 | 6 | 7 |
6 | 35.12 | 25 | 14.73 | 445 | 6 | 7 |
7 | 0.08 | 244 | 14.38 | 366 | 6 | 173 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.68 | 27 | 14.74 | 519 | 6 | 6 |
2 | 908.52 | -1 | 14.74 | 519 | 6 | 6 |
3 | 946.20 | -1 | 14.74 | 519 | 6 | 6 |
4 | 1496.88 | 70 | 13.08 | 2818 | 6 | 6 |
5 | 806.00 | 25 | 13.76 | 1747 | 6 | 6 |
6 | 142.76 | 25 | 14.49 | 653 | 6 | 7 |
7 | 34.44 | 25 | 14.68 | 440 | 6 | 8 |
8 | -0.04 | 244 | 14.34 | 370 | 6 | 175 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.28 | 24 | 14.93 | 480 | 7 | 7 |
2 | 1019.72 | 1 | 14.29 | 2134 | 6 | 6 |
3 | 1001.48 | 70 | 13.33 | 2046 | 6 | 7 |
4 | 74.68 | 25 | 14.53 | 530 | 6 | 7 |
5 | 34.68 | 25 | 14.57 | 445 | 6 | 8 |
6 | 0.04 | 237 | 14.31 | 369 | 6 | 173 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 142.32 | 70 | 14.51 | 518 | 158 | 7 |
2 | 100.36 | 25 | 14.82 | 461 | 7 | 7 |
3 | 54.00 | 25 | 14.86 | 385 | 7 | 7 |
4 | 0.20 | 247 | 14.70 | 304 | 7 | 166 |