SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8174 WMO= 5904369


Cycle 95 GMT 16/ 2/2016 0:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.08 32 14.55 500 6 6
2 1132.96 6 10.61 2096 6 6
3 2003.00 70 10.88 3351 6 6
4 1440.36 30 12.74 2499 6 6
5 620.52 30 13.61 1280 6 6
6 44.52 30 14.47 395 6 6
7 0.84 190 14.40 316 6 27

Cycle 94 GMT 6/ 2/2016 0:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 31 14.55 480 6 6
2 1121.76 6 10.82 2076 6 6
3 1819.44 70 11.15 3074 6 6
4 1294.56 30 12.89 2260 6 6
5 573.80 30 13.67 1224 6 6
6 36.12 30 14.49 413 6 6
7 0.08 191 14.36 356 6 23

Cycle 93 GMT 26/ 1/2016 23:57: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 31 14.55 480 6 6
2 1125.20 6 10.55 2108 6 6
3 1887.36 70 10.97 3179 6 6
4 1364.08 30 12.81 2369 6 6
5 534.52 30 13.73 1156 6 6
6 24.80 30 14.53 353 6 6
7 -0.04 191 14.42 315 6 21

Cycle 92 GMT 16/ 1/2016 23:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.68 31 14.48 461 6 6
2 1125.52 6 10.53 2089 6 6
3 1816.84 70 11.10 3085 6 6
4 1177.92 30 13.03 2114 6 6
5 631.36 30 13.63 1281 6 6
6 30.20 30 14.48 372 6 6
7 0.12 191 14.40 320 6 26

Cycle 91 GMT 6/ 1/2016 23: 2: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.76 31 14.55 461 6 6
2 1131.68 6 10.89 2057 6 6
3 1764.08 70 11.19 3013 6 6
4 1262.92 30 12.95 2222 6 6
5 430.92 30 13.86 999 6 6
6 14.08 30 14.54 352 6 6
7 0.00 191 14.33 319 6 24

Cycle 90 GMT 27/12/2015 22:47:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.88 31 14.55 461 6 6
2 1117.76 6 10.81 2038 6 6
3 1731.88 70 11.26 2954 6 6
4 1214.76 30 12.99 2156 6 6
5 273.20 30 14.06 772 6 6
6 24.00 30 14.47 374 6 7
7 0.04 191 14.34 328 6 30

Cycle 89 GMT 17/12/2015 22:34:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.68 31 14.48 480 6 6
2 1112.80 6 10.70 2057 6 6
3 1566.28 70 11.39 2721 6 6
4 1185.24 30 13.01 2100 6 6
5 228.92 30 14.14 701 6 6
6 37.92 30 14.45 388 6 7
7 -0.04 191 14.34 325 6 30

Cycle 88 GMT 7/12/2015 22:43:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 31 14.48 461 6 6
2 1110.88 6 10.76 2044 6 6
3 1626.96 70 11.27 2806 6 6
4 1117.48 30 13.09 1993 6 6
5 319.04 30 14.02 839 6 6
6 0.12 191 14.37 326 6 21

Cycle 87 GMT 27/11/2015 22:46: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.04 31 14.55 480 6 6
2 1128.40 6 10.30 2050 6 6
3 1812.88 70 11.07 3068 6 6
4 1159.80 30 13.08 2073 6 6
5 477.08 30 13.84 1073 6 6
6 3.68 30 14.54 332 6 6
7 0.04 191 14.34 317 6 24

Cycle 86 GMT 17/11/2015 22:22:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 31 14.48 480 6 6
2 1128.28 6 10.30 2121 6 6
3 1769.92 70 11.09 3020 6 6
4 1244.80 30 13.00 2177 6 6
5 680.04 30 13.56 1355 6 6
6 0.20 191 14.41 317 6 14

Cycle 85 GMT 7/11/2015 22:18: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.60 31 14.55 461 6 6
2 1131.32 6 10.80 2050 6 6
3 1743.04 70 11.16 2983 6 6
4 1103.36 30 13.11 1988 6 6
5 567.92 30 13.70 1200 6 6
6 0.04 191 14.41 316 6 22

Cycle 84 GMT 28/10/2015 22: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 31 14.48 480 6 6
2 1126.36 6 10.40 2076 6 6
3 1993.60 70 10.92 3347 6 6
4 1213.24 30 13.10 2148 6 6
5 537.80 30 13.77 1162 6 6
6 10.20 30 14.57 331 6 6
7 0.04 191 14.37 314 6 30

Cycle 83 GMT 18/10/2015 20:53: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.60 31 14.55 461 6 6
2 1125.68 6 10.30 2070 6 6
3 1994.96 70 10.95 3329 6 6
4 1321.24 30 12.99 2326 6 6
5 495.60 30 13.81 1111 6 6
6 5.28 30 14.57 329 6 6
7 0.04 191 14.36 319 6 20

Cycle 82 GMT 8/10/2015 20: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.80 31 14.55 480 6 6
2 1135.76 5 10.66 2076 6 6
3 1818.96 70 11.11 3076 6 6
4 1291.88 22 13.13 2268 6 6
5 654.24 22 13.76 1319 6 6
6 124.36 22 14.42 523 6 6
7 0.60 190 14.44 314 6 23

Cycle 81 GMT 28/ 9/2015 19:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.40 31 14.55 480 6 6
2 1121.32 5 10.51 2089 6 6
3 2003.04 70 11.03 3342 6 6
4 1210.76 22 13.20 2164 6 6
5 687.56 22 13.71 1388 6 6
6 155.52 22 14.35 571 6 6
7 0.16 191 14.44 318 6 17

Cycle 80 GMT 18/ 9/2015 18:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 31 14.61 480 6 6
2 1122.84 5 10.59 2064 6 6
3 2003.20 70 10.95 3369 6 6
4 1447.36 22 13.02 2516 6 6
5 657.80 22 13.75 1354 6 6
6 143.88 22 14.35 561 6 6
7 0.08 191 14.44 324 6 22

Cycle 79 GMT 8/ 9/2015 18: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.96 31 14.55 480 6 6
2 1116.68 5 10.61 2044 6 6
3 1998.68 70 11.06 3351 6 6
4 1357.28 22 13.16 2394 6 6
5 714.68 22 13.70 1401 6 6
6 195.36 22 14.32 631 6 6
7 0.12 191 14.43 317 6 23

Cycle 78 GMT 29/ 8/2015 16:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.00 31 14.48 480 6 6
2 1131.68 5 10.93 2095 6 6
3 2000.32 70 11.06 3355 6 6
4 1444.48 22 13.01 2533 6 6
5 766.12 22 13.61 1495 6 6
6 231.72 22 14.28 696 6 6
7 0.08 191 14.41 326 6 19

Cycle 77 GMT 19/ 8/2015 16:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 31 14.61 461 6 6
2 1125.60 5 10.97 2050 6 6
3 2001.20 70 11.09 3355 6 6
4 1322.00 22 13.14 2350 6 6
5 664.32 22 13.77 1354 6 6
6 144.24 22 14.42 554 6 6
7 0.24 191 14.46 317 6 19

Cycle 76 GMT 9/ 8/2015 15:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.16 31 14.55 461 6 6
2 1124.92 5 11.04 2076 6 6
3 1997.56 70 11.10 3349 6 6
4 1327.24 22 13.12 2328 6 6
5 682.80 22 13.74 1388 6 6
6 150.36 22 14.40 563 6 6
7 0.04 191 14.44 324 6 22

Cycle 75 GMT 30/ 7/2015 14:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.68 31 14.61 480 6 6
2 1129.56 4 10.79 2086 6 6
3 2001.72 70 11.20 3354 6 6
4 1460.04 22 13.03 2550 6 6
5 777.64 22 13.66 1512 6 6
6 226.92 22 14.27 689 6 6
7 0.00 191 14.42 325 6 21

Cycle 74 GMT 20/ 7/2015 14:40: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.48 31 14.61 480 6 6
2 1135.80 4 11.10 2066 6 6
3 2002.12 70 11.25 3353 6 6
4 1221.88 22 13.26 2189 6 6
5 600.96 22 13.86 1232 6 6
6 202.60 22 14.35 644 6 6
7 0.16 190 14.42 323 6 22

Cycle 73 GMT 10/ 7/2015 14:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 31 14.61 461 6 6
2 1127.48 4 11.42 2086 6 6
3 2002.84 70 11.28 3346 6 6
4 1217.08 22 13.29 2155 6 6
5 590.84 22 13.88 1243 6 6
6 192.80 22 14.37 640 6 6
7 13.04 22 14.58 350 6 6
8 0.08 190 14.38 317 6 27

Cycle 72 GMT 30/ 6/2015 13:47: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 30 14.61 480 6 6
2 1123.68 4 11.42 2047 6 6
3 2001.36 70 11.32 3351 6 6
4 1315.12 22 13.22 2328 6 6
5 656.32 22 13.81 1326 6 6
6 130.44 22 14.43 542 6 6
7 26.16 22 14.56 375 6 6
8 0.08 191 14.40 323 6 21

Cycle 71 GMT 20/ 6/2015 13:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.60 30 14.68 461 6 6
2 1126.16 4 11.58 2096 6 6
3 2002.96 70 11.39 3346 6 6
4 1437.08 22 13.12 2497 6 6
5 752.28 22 13.74 1482 6 6
6 202.12 22 14.30 657 6 6
7 0.04 191 14.42 325 6 16

Cycle 70 GMT 10/ 6/2015 13:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.04 30 14.68 461 6 6
2 1124.40 4 11.93 2095 6 6
3 2002.28 70 11.42 3341 6 6
4 1298.72 22 13.17 2307 6 6
5 757.88 22 13.69 1508 6 6
6 109.40 22 14.41 504 6 6
7 0.20 191 14.44 322 6 19

Cycle 69 GMT 31/ 5/2015 12:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.44 30 14.48 500 6 6
2 1115.96 4 11.68 2086 6 6
3 2003.48 70 11.49 3312 6 6
4 1322.68 22 13.22 2322 6 6
5 660.52 22 13.80 1322 6 6
6 124.16 22 14.40 533 6 6
7 0.12 191 14.42 325 6 16

Cycle 68 GMT 21/ 5/2015 12:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.44 30 14.55 480 6 6
2 1114.20 4 11.84 2076 6 6
3 2002.76 70 11.49 3359 6 6
4 1192.72 22 13.36 2138 6 6
5 556.52 22 13.90 1194 6 6
6 152.20 22 14.35 574 6 6
7 0.16 191 14.41 321 6 18

Cycle 67 GMT 11/ 5/2015 11:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 30 14.61 461 6 6
2 1126.80 5 11.93 2089 6 6
3 1982.64 70 11.51 3312 6 6
4 1176.80 22 13.37 2129 6 6
5 540.24 22 13.93 1164 6 6
6 138.92 22 14.41 552 6 6
7 1.12 22 14.59 328 6 6
8 0.00 191 14.38 322 6 21

Cycle 66 GMT 1/ 5/2015 10:47: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.88 30 14.61 461 6 6
2 1127.08 5 11.85 2089 6 6
3 1988.80 26 11.90 3360 6 6
4 1902.92 22 12.74 3236 6 6
5 1538.36 22 13.12 2634 6 6
6 902.76 22 13.57 1706 6 6
7 504.40 22 13.93 1112 6 6
8 28.32 22 14.49 375 6 6
9 0.00 191 14.34 315 6 17

Cycle 65 GMT 21/ 4/2015 9:40: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.68 30 14.61 461 6 6
2 1132.12 4 11.84 2095 6 6
3 2002.08 26 11.85 3362 6 6
4 1906.88 22 12.77 3202 6 6
5 1537.44 22 13.16 2640 6 6
6 1019.12 22 13.53 1854 6 6
7 493.08 22 13.97 1099 6 6
8 58.96 22 14.51 418 6 6
9 0.12 191 14.41 311 6 18

Cycle 64 GMT 11/ 4/2015 9: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.60 30 14.61 480 6 6
2 1134.60 2 11.24 2134 6 6
3 2009.76 27 12.03 3352 6 6
4 1929.52 22 12.79 3273 6 6
5 1806.36 22 12.95 3087 6 6
6 1229.40 22 13.42 2181 6 6
7 657.44 22 13.82 1334 6 6
8 106.96 22 14.43 504 6 6
9 22.44 22 14.50 360 6 6
10 0.08 191 14.37 315 6 25

Cycle 63 GMT 1/ 4/2015 9:19: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.96 30 14.61 461 6 6
2 1141.64 2 11.56 2134 6 6
3 2000.32 27 12.03 3371 6 6
4 1901.04 22 12.88 3206 6 6
5 1775.12 22 12.99 3018 6 6
6 1343.68 22 13.35 2343 6 6
7 620.44 22 13.86 1266 6 6
8 93.04 22 14.41 475 6 6
9 18.16 22 14.50 356 6 6
10 6.00 22 14.45 339 6 7
11 0.00 191 14.32 316 6 32

Cycle 62 GMT 22/ 3/2015 9:34: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.16 30 14.68 461 6 6
2 1126.72 2 12.19 2038 6 6
3 2004.04 27 12.11 3376 6 6
4 1907.92 22 12.85 3202 6 6
5 1780.52 22 12.98 3010 6 6
6 1211.88 22 13.39 2191 6 6
7 506.04 22 13.98 1119 6 6
8 100.16 22 14.46 484 6 6
9 0.24 191 14.41 321 6 24

Cycle 61 GMT 12/ 3/2015 9:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.76 30 14.61 480 6 6
2 1124.12 2 12.00 2076 6 6
3 2004.48 27 12.20 3393 6 6
4 1916.72 22 12.88 3221 6 6
5 1789.00 22 13.03 3023 6 6
6 1096.08 22 13.51 1965 6 6
7 671.76 22 13.82 1352 6 6
8 97.24 22 14.44 480 6 6
9 0.12 191 14.39 319 6 19

Cycle 60 GMT 2/ 3/2015 9:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.88 30 14.68 461 6 6
2 1122.28 2 11.94 2134 6 6
3 2005.56 27 12.25 3400 6 6
4 1917.36 22 12.86 3262 6 6
5 1785.60 22 13.01 3065 6 6
6 1097.36 22 13.47 1988 6 6
7 535.04 22 13.93 1161 6 6
8 52.36 22 14.48 422 6 6
9 24.24 22 14.44 377 6 6
10 0.04 191 14.31 324 6 20

Cycle 59 GMT 20/ 2/2015 9:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.44 30 14.61 461 6 6
2 1118.20 2 12.44 2076 6 6
3 2003.08 27 12.36 3375 6 6
4 1908.36 22 12.91 3219 6 6
5 1650.64 22 13.15 2809 6 6
6 1232.04 22 13.43 2181 6 6
7 516.04 22 13.98 1129 6 6
8 102.92 22 14.46 495 6 6
9 4.20 22 14.53 341 6 6
10 -0.08 191 14.35 320 6 29

Cycle 58 GMT 10/ 2/2015 10:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.04 30 14.68 461 6 6
2 1116.48 2 12.63 2096 6 6
3 2003.32 27 12.42 3398 6 6
4 1909.88 22 12.92 3202 6 6
5 1648.12 22 13.16 2820 6 6
6 1372.28 22 13.36 2392 6 6
7 639.48 22 13.87 1303 6 6
8 47.80 22 14.52 407 6 6
9 24.48 22 14.47 369 6 6
10 0.16 191 14.33 322 6 28

Cycle 57 GMT 31/ 1/2015 10:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.56 30 14.68 461 6 6
2 1136.56 2 12.70 2134 6 6
3 2004.12 27 12.51 3361 6 6
4 1913.32 22 12.96 3217 6 6
5 1651.88 22 13.17 2837 6 6
6 1099.36 22 13.56 1976 6 6
7 405.96 22 14.11 978 6 6
8 64.24 22 14.53 433 6 6
9 30.80 22 14.49 371 6 6
10 0.16 191 14.37 315 6 23

Cycle 56 GMT 21/ 1/2015 10:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 30 14.68 461 6 6
2 1128.72 2 12.70 2134 6 6
3 2001.84 27 12.51 3367 6 6
4 1906.60 22 12.92 3230 6 6
5 1778.08 22 13.03 3033 6 6
6 1083.64 22 13.54 1978 6 6
7 532.40 22 14.00 1146 6 6
8 103.92 22 14.46 495 6 6
9 0.08 191 14.42 318 6 23

Cycle 55 GMT 11/ 1/2015 10:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.32 30 14.61 461 6 6
2 1140.92 2 12.82 2134 6 6
3 2006.60 27 12.52 3368 6 6
4 1913.60 22 12.93 3234 6 6
5 1653.76 22 13.13 2834 6 6
6 1090.36 22 13.51 2008 6 6
7 521.24 22 14.00 1140 6 6
8 50.00 22 14.54 409 6 6
9 0.12 191 14.41 319 6 24

Cycle 54 GMT 1/ 1/2015 10:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 30 14.61 480 6 6
2 1127.16 2 12.89 2076 6 6
3 2005.60 29 12.57 3380 6 6
4 1903.40 16 13.02 3199 6 6
5 1783.24 16 13.17 3018 6 6
6 1382.76 16 13.42 2422 6 6
7 980.12 16 13.69 1804 6 6
8 570.16 16 14.05 1194 6 6
9 157.32 16 14.41 581 6 6
10 29.84 16 14.59 381 6 6
11 0.16 191 14.39 318 6 22

Cycle 53 GMT 22/12/2014 10:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.80 30 14.68 461 6 6
2 1121.36 2 12.70 2096 6 6
3 2005.52 29 12.59 3398 6 6
4 1905.16 16 13.00 3208 6 6
5 1779.00 16 13.14 3051 6 6
6 1513.48 16 13.36 2620 6 6
7 961.00 16 13.74 1760 6 6
8 683.76 16 13.94 1353 6 6
9 251.88 16 14.34 735 6 6
10 19.68 16 14.56 367 6 6
11 0.12 191 14.39 322 6 21

Cycle 52 GMT 12/12/2014 10:47:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.56 30 14.68 461 6 6
2 1109.88 2 12.82 2057 6 6
3 2001.44 29 12.63 3340 6 6
4 1912.28 16 13.04 3227 6 6
5 1786.00 16 13.14 3040 6 6
6 1228.92 16 13.56 2161 6 6
7 962.40 16 13.74 1763 6 6
8 553.08 16 14.01 1183 6 6
9 135.92 16 14.44 554 6 6
10 24.08 16 14.56 370 6 6
11 0.00 191 14.36 323 6 26

Cycle 51 GMT 2/12/2014 10:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.28 30 14.68 480 6 6
2 1109.80 2 12.76 2057 6 6
3 2003.68 29 12.70 3381 6 6
4 1904.76 16 13.03 3257 6 6
5 1780.96 16 13.17 3024 6 6
6 1352.92 16 13.46 2375 6 6
7 944.48 16 13.74 1757 6 6
8 522.32 16 14.08 1142 6 6
9 115.12 16 14.49 513 6 6
10 27.84 16 14.56 370 6 6
11 14.24 16 14.57 348 6 6
12 0.04 191 14.37 324 6 31

Cycle 50 GMT 22/11/2014 10:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.56 30 14.68 480 6 6
2 1115.08 2 12.76 2096 6 6
3 2001.92 29 12.76 3349 6 6
4 1902.00 16 13.06 3225 6 6
5 1777.36 16 13.19 3029 6 6
6 1381.84 16 13.51 2389 6 6
7 977.68 16 13.76 1774 6 6
8 432.16 16 14.16 1005 6 6
9 162.60 16 14.48 590 6 6
10 11.64 16 14.62 351 6 6
11 0.16 191 14.39 320 6 25

Cycle 49 GMT 12/11/2014 10:51:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.92 30 14.68 480 6 6
2 1119.04 2 12.89 2096 6 6
3 2002.28 29 12.77 3387 6 6
4 1898.76 16 13.11 3224 6 6
5 1768.12 16 13.21 3032 6 6
6 1233.12 16 13.58 2211 6 6
7 964.48 16 13.77 1774 6 6
8 538.60 16 14.10 1164 6 6
9 118.28 16 14.53 519 6 6
10 0.20 191 14.45 320 6 19

Cycle 48 GMT 2/11/2014 11: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.80 30 14.68 480 6 6
2 1114.48 2 13.02 2076 6 6
3 2006.32 29 12.86 3374 6 6
4 1905.60 16 13.09 3219 6 6
5 1652.20 16 13.34 2799 6 6
6 1526.64 16 13.41 2631 6 6
7 955.52 16 13.77 1760 6 6
8 414.12 16 14.21 1002 6 6
9 147.16 16 14.52 565 6 6
10 9.20 16 14.61 348 6 6
11 0.08 191 14.41 321 6 22

Cycle 47 GMT 23/10/2014 10:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.04 30 14.68 480 6 6
2 1127.76 2 13.14 2115 6 6
3 2001.88 29 12.88 3376 6 6
4 1893.44 16 13.19 3202 6 6
5 1771.48 16 13.27 3021 6 6
6 1221.28 16 13.61 2172 6 6
7 956.80 16 13.81 1744 6 6
8 562.72 16 14.11 1197 6 6
9 66.36 16 14.60 436 6 6
10 12.20 16 14.62 351 6 6
11 0.08 191 14.39 320 6 26

Cycle 46 GMT 13/10/2014 10:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.16 30 14.68 461 6 6
2 2001.16 29 13.16 3378 6 6
3 1922.92 16 13.24 3216 6 6
4 1821.60 16 13.29 3076 6 6
5 1367.60 16 13.61 2389 6 6
6 1009.76 16 13.81 1856 6 6
7 552.68 16 14.14 1172 6 6
8 198.12 16 14.48 653 6 6
9 0.04 191 14.44 326 6 19

Cycle 45 GMT 3/10/2014 11: 9: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.52 30 14.68 480 6 6
2 2005.48 29 13.16 3372 6 6
3 1916.80 16 13.23 3249 6 6
4 1807.76 16 13.30 3068 6 6
5 1462.64 16 13.56 2557 6 6
6 998.00 16 13.83 1837 6 6
7 538.28 16 14.16 1172 6 6
8 92.20 16 14.59 474 6 6
9 0.00 190 14.44 321 6 21

Cycle 44 GMT 23/ 9/2014 11:18: 3

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.16 30 14.74 461 6 6
2 2001.28 29 13.17 3360 6 6
3 1913.12 16 13.27 3224 6 6
4 1809.28 16 13.33 3095 6 6
5 1377.08 16 13.62 2400 6 6
6 1042.56 16 13.82 1886 6 6
7 579.36 16 14.16 1222 6 6
8 110.44 16 14.61 502 6 6
9 0.12 191 14.48 322 6 23

Cycle 43 GMT 13/ 9/2014 11:25: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.16 30 14.74 461 6 6
2 2003.64 29 13.18 3380 6 6
3 1926.76 16 13.23 3255 6 6
4 1828.04 16 13.36 3071 6 6
5 1482.60 16 13.58 2579 6 6
6 1023.36 16 13.85 1864 6 6
7 448.20 16 14.29 1038 6 6
8 117.32 16 14.61 513 6 6
9 0.32 190 14.49 320 6 20

Cycle 42 GMT 3/ 9/2014 11:35:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.72 30 14.74 480 6 6
2 2001.36 29 13.13 3369 6 6
3 1918.64 16 13.22 3249 6 6
4 1815.80 16 13.32 3087 6 6
5 1461.16 16 13.59 2562 6 6
6 992.80 16 13.88 1837 6 6
7 422.28 16 14.31 1005 6 6
8 194.92 16 14.54 639 6 6
9 0.20 191 14.50 318 6 22

Cycle 41 GMT 24/ 8/2014 11:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.16 30 14.74 461 6 6
2 2002.48 29 13.13 3373 6 6
3 1918.36 16 13.28 3211 6 6
4 1812.32 16 13.38 3049 6 6
5 1353.36 16 13.66 2408 6 6
6 1016.28 16 13.86 1851 6 6
7 534.64 16 14.20 1169 6 6
8 182.48 16 14.56 623 6 6
9 16.00 16 14.71 356 6 6
10 0.00 190 14.47 320 6 23

Cycle 40 GMT 14/ 8/2014 12:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.32 30 14.68 480 6 6
2 2005.48 29 13.06 3364 6 6
3 1931.64 16 13.25 3271 6 6
4 1829.76 16 13.31 3136 6 6
5 1365.60 16 13.66 2381 6 6
6 1131.04 16 13.81 2032 6 6
7 539.40 16 14.21 1169 6 6
8 187.08 16 14.58 623 6 6
9 0.08 190 14.49 318 6 18

Cycle 39 GMT 4/ 8/2014 12:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.20 30 14.68 500 6 6
2 2006.36 29 13.08 3376 6 6
3 1923.64 16 13.23 3268 6 6
4 1702.80 16 13.45 2895 6 6
5 1469.92 16 13.59 2584 6 6
6 1101.96 16 13.81 2007 6 6
7 493.56 16 14.23 1103 6 6
8 137.56 16 14.58 554 6 6
9 25.12 16 14.68 381 6 6
10 0.08 191 14.43 328 6 27

Cycle 38 GMT 25/ 7/2014 13: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.16 29 14.74 480 6 6
2 2002.96 29 12.98 3382 6 6
3 1913.88 16 13.25 3249 6 6
4 1690.36 16 13.44 2895 6 6
5 1580.56 16 13.48 2730 6 6
6 984.00 16 13.89 1807 6 6
7 518.20 16 14.24 1131 6 6
8 81.04 16 14.68 450 6 6
9 0.24 191 14.48 318 6 17

Cycle 37 GMT 15/ 7/2014 13:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 29 14.74 480 6 6
2 2001.52 29 12.98 3400 6 6
3 1908.64 16 13.27 3232 6 6
4 1703.48 16 13.47 2906 6 6
5 1593.72 16 13.49 2735 6 6
6 985.88 16 13.90 1799 6 6
7 512.40 16 14.24 1126 6 6
8 162.56 16 14.56 590 6 6
9 0.16 191 14.48 327 6 20

Cycle 36 GMT 5/ 7/2014 14: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.44 29 14.68 480 6 6
2 2005.76 29 12.95 3400 6 6
3 1918.92 16 13.18 3282 6 6
4 1811.96 16 13.30 3082 6 6
5 1353.12 16 13.69 2367 6 6
6 1001.04 16 13.90 1834 6 6
7 526.20 16 14.19 1158 6 6
8 84.84 16 14.65 463 6 6
9 0.04 191 14.46 326 6 22

Cycle 35 GMT 25/ 6/2014 14:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.64 29 14.74 461 6 6
2 2003.12 29 12.96 3363 6 6
3 1924.96 16 13.23 3247 6 6
4 1829.76 16 13.31 3054 6 6
5 1471.36 16 13.59 2560 6 6
6 1110.80 16 13.82 1999 6 6
7 520.64 16 14.23 1134 6 6
8 175.32 15 14.56 621 6 6
9 18.40 16 14.74 359 6 6
10 0.08 191 14.46 318 6 25

Cycle 34 GMT 15/ 6/2014 14:43: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.72 29 14.74 461 6 6
2 2003.20 29 12.97 3366 6 6
3 1923.32 16 13.23 3285 6 6
4 1814.20 16 13.33 3057 6 6
5 1578.24 16 13.52 2700 6 6
6 974.28 16 13.90 1779 6 6
7 509.56 16 14.24 1123 6 6
8 160.56 16 14.59 587 6 6
9 0.08 191 14.50 318 6 23

Cycle 33 GMT 5/ 6/2014 15: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 29 14.74 461 6 6
2 2004.32 29 13.00 3386 6 6
3 1924.12 16 13.23 3246 6 6
4 1818.88 16 13.30 3103 6 6
5 1471.68 16 13.61 2507 6 6
6 906.24 16 13.96 1697 6 6
7 465.72 15 14.31 1066 6 6
8 228.60 15 14.52 704 6 6
9 50.64 15 14.72 416 6 6
10 25.00 16 14.66 378 6 6
11 0.04 191 14.46 315 6 24

Cycle 32 GMT 26/ 5/2014 15:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.44 29 14.74 461 6 6
2 2005.32 29 13.05 3374 6 6
3 1926.64 16 13.19 3265 6 6
4 1820.92 16 13.32 3068 6 6
5 1470.00 16 13.59 2540 6 6
6 1014.80 16 13.90 1856 6 6
7 529.32 16 14.24 1145 6 6
8 166.68 16 14.60 598 6 6
9 13.24 15 14.75 352 6 6
10 0.08 191 14.47 318 6 24

Cycle 31 GMT 16/ 5/2014 15:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 29 14.74 442 6 6
2 2000.64 29 13.07 3409 6 6
3 1917.52 16 13.23 3246 6 6
4 1814.24 16 13.34 3021 6 6
5 1469.68 16 13.60 2546 6 6
6 1116.44 16 13.85 1993 6 6
7 522.68 15 14.25 1150 6 6
8 176.08 16 14.58 620 6 6
9 36.16 15 14.73 390 6 6
10 0.24 191 14.46 318 6 30

Cycle 30 GMT 6/ 5/2014 15:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.32 29 14.80 461 6 6
2 2005.44 29 13.12 3390 6 6
3 1917.12 16 13.23 3271 6 6
4 1705.92 16 13.44 2900 6 6
5 1372.64 16 13.64 2433 6 6
6 905.80 16 13.97 1694 6 6
7 434.32 15 14.34 1038 6 6
8 210.40 15 14.57 682 6 6
9 43.56 15 14.76 399 6 6
10 0.16 191 14.48 320 6 25

Cycle 29 GMT 26/ 4/2014 16:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.80 29 14.80 461 6 6
2 2002.64 29 13.18 3367 6 6
3 1907.52 16 13.25 3194 6 6
4 1693.80 16 13.46 2875 6 6
5 1361.32 16 13.69 2406 6 6
6 797.44 16 14.03 1530 6 6
7 362.72 15 14.40 929 6 6
8 142.12 15 14.63 569 6 6
9 29.36 15 14.78 368 6 6
10 0.12 191 14.49 318 6 24

Cycle 28 GMT 16/ 4/2014 16:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.44 29 14.80 461 6 6
2 2005.04 29 13.19 3379 6 6
3 1913.44 16 13.22 3271 6 6
4 1692.44 16 13.44 2862 6 6
5 1360.20 16 13.68 2384 6 6
6 903.36 16 13.98 1694 6 6
7 551.44 16 14.24 1211 6 6
8 90.68 16 14.67 482 6 6
9 0.08 190 14.47 325 6 15

Cycle 27 GMT 6/ 4/2014 16:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.28 29 14.74 500 6 6
2 2005.72 29 13.20 3378 6 6
3 1916.60 16 13.24 3249 6 6
4 1808.92 16 13.32 3101 6 6
5 1359.64 16 13.69 2403 6 6
6 1000.48 16 13.93 1823 6 6
7 527.44 16 14.24 1161 6 6
8 176.28 16 14.60 625 6 6
9 34.60 16 14.77 386 6 6
10 0.08 191 14.49 319 6 22

Cycle 26 GMT 27/ 3/2014 16:49: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.36 29 14.74 480 6 6
2 2002.24 29 13.22 3385 6 6
3 1918.64 16 13.24 3252 6 6
4 1813.72 16 13.35 3057 6 6
5 1460.20 16 13.64 2532 6 6
6 999.60 16 13.91 1831 6 6
7 523.48 15 14.28 1166 6 6
8 174.32 15 14.63 615 6 6
9 40.20 15 14.78 400 6 6
10 0.00 190 14.50 318 6 25

Cycle 25 GMT 17/ 3/2014 17: 8: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.84 29 14.80 461 6 6
2 2004.64 29 13.26 3378 6 6
3 1925.68 16 13.27 3282 6 6
4 1826.64 16 13.35 3090 6 6
5 1369.76 16 13.72 2364 6 6
6 1260.08 16 13.71 2241 6 6
7 625.68 16 14.18 1310 6 6
8 150.04 16 14.65 579 6 6
9 15.64 16 14.80 359 6 6
10 2.84 16 14.76 331 6 7
11 0.12 191 14.47 313 6 25

Cycle 24 GMT 7/ 3/2014 17:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.92 29 14.80 461 6 6
2 2003.00 29 13.31 3362 6 6
3 1912.60 16 13.24 3252 6 6
4 1809.00 16 13.36 3084 6 6
5 1247.72 16 13.79 2224 6 6
6 1022.12 16 13.93 1859 6 6
7 441.60 16 14.35 1032 6 6
8 106.12 16 14.71 500 6 6
9 49.72 16 14.74 408 6 6
10 0.12 191 14.50 316 6 28

Cycle 23 GMT 25/ 2/2014 17:14: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.68 29 14.74 480 6 6
2 2003.40 29 13.34 3377 6 6
3 1905.56 16 13.33 3205 6 6
4 1684.20 16 13.51 2887 6 6
5 1459.88 16 13.67 2518 6 6
6 986.56 16 13.97 1818 6 6
7 615.32 16 14.21 1288 6 6
8 125.96 16 14.68 538 6 6
9 10.44 16 14.83 354 6 6
10 0.12 191 14.49 322 6 28

Cycle 22 GMT 15/ 2/2014 17:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.00 29 14.80 461 6 6
2 2006.44 29 13.32 3393 6 6
3 1914.68 16 13.32 3252 6 6
4 1702.04 16 13.50 2919 6 6
5 1268.56 16 13.78 2235 6 6
6 926.24 16 14.01 1708 6 6
7 459.84 15 14.33 1073 6 6
8 112.84 15 14.71 519 6 6
9 23.16 15 14.82 368 6 6
10 0.12 191 14.51 318 6 17

Cycle 21 GMT 5/ 2/2014 17:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.16 29 14.80 480 6 6
2 2001.12 29 13.35 3342 6 6
3 1908.32 16 13.34 3235 6 6
4 1691.36 16 13.50 2886 6 6
5 1244.28 16 13.80 2205 6 6
6 894.68 16 14.03 1672 6 6
7 418.60 15 14.39 1009 6 6
8 89.96 15 14.76 476 6 6
9 0.12 191 14.55 319 6 19

Cycle 20 GMT 26/ 1/2014 17:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 29 14.87 480 6 6
2 2005.32 29 13.35 3368 6 6
3 1920.60 16 13.31 3260 6 6
4 1709.08 16 13.51 2895 6 6
5 1260.12 16 13.78 2230 6 6
6 1037.48 16 13.93 1870 6 6
7 445.60 16 14.37 1043 6 6
8 214.36 15 14.62 682 6 6
9 38.36 15 14.82 393 6 6
10 0.52 190 14.52 319 6 28

Cycle 19 GMT 16/ 1/2014 18: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.00 29 14.87 461 6 6
2 2002.12 29 13.38 3340 6 6
3 1916.84 16 13.30 3235 6 6
4 1811.60 16 13.46 3021 6 6
5 1244.64 16 13.81 2183 6 6
6 902.68 16 14.06 1667 6 6
7 447.16 15 14.38 1057 6 6
8 103.36 16 14.75 494 6 6
9 23.56 15 14.85 377 6 6
10 0.12 191 14.54 323 6 20

Cycle 18 GMT 6/ 1/2014 18: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.96 29 14.87 461 6 6
2 2004.24 29 13.33 3419 6 6
3 1923.68 16 13.39 3222 6 6
4 1814.00 16 13.42 3109 6 6
5 1335.24 16 13.73 2351 6 6
6 991.64 16 13.98 1812 6 6
7 415.88 15 14.42 999 6 6
8 96.52 15 14.79 496 6 6
9 21.56 15 14.85 371 6 6
10 0.16 191 14.53 327 6 22

Cycle 17 GMT 27/12/2013 18:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 29 14.87 480 6 6
2 2001.84 29 13.40 3362 6 6
3 1914.60 16 13.37 3227 6 6
4 1703.20 16 13.52 2917 6 6
5 1254.16 16 13.81 2216 6 6
6 920.76 16 14.04 1708 6 6
7 454.48 16 14.36 1059 6 6
8 106.76 16 14.77 508 6 6
9 8.08 15 14.88 355 6 6
10 0.08 191 14.55 320 6 22

Cycle 16 GMT 17/12/2013 18:38:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.80 29 14.87 461 6 6
2 2002.20 29 13.41 3356 6 6
3 1920.08 16 13.41 3241 6 6
4 1817.80 16 13.47 3093 6 6
5 1350.44 16 13.75 2389 6 6
6 893.92 15 14.07 1659 6 6
7 551.64 15 14.30 1195 6 6
8 103.36 15 14.80 503 6 6
9 7.16 16 14.91 348 6 6
10 0.12 191 14.53 329 6 18

Cycle 15 GMT 7/12/2013 18:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.24 29 14.87 480 6 6
2 2003.60 29 13.40 3381 6 6
3 1912.20 16 13.39 3197 6 6
4 1809.12 16 13.49 3029 6 6
5 1349.96 16 13.76 2362 6 6
6 987.64 16 13.99 1801 6 6
7 404.64 15 14.45 964 6 6
8 173.20 16 14.67 615 6 6
9 27.48 15 14.86 380 6 6
10 0.04 191 14.55 321 6 22

Cycle 14 GMT 27/11/2013 19: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.60 29 14.87 480 6 6
2 2003.36 29 13.41 3372 6 6
3 1910.28 16 13.41 3172 6 6
4 1700.68 16 13.56 2928 6 6
5 1252.20 16 13.83 2233 6 6
6 905.24 15 14.10 1675 6 6
7 443.64 15 14.42 1015 6 6
8 106.48 16 14.78 505 6 6
9 24.04 16 14.86 384 6 6
10 0.08 191 14.54 328 6 19

Cycle 13 GMT 17/11/2013 19: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.24 29 14.87 480 6 6
2 2008.00 29 13.42 3378 6 6
3 1925.52 16 13.42 3216 6 6
4 1708.60 16 13.55 2922 6 6
5 1368.92 16 13.75 2386 6 6
6 805.56 15 14.12 1585 6 6
7 575.72 15 14.29 1233 6 6
8 108.52 15 14.82 512 6 6
9 21.24 15 14.91 374 6 6
10 0.12 191 14.55 326 6 23

Cycle 12 GMT 7/11/2013 19:22: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.56 29 14.87 480 6 6
2 2000.88 29 13.44 3360 6 6
3 1911.40 16 13.45 3194 6 6
4 1684.32 16 13.57 2892 6 6
5 1456.20 16 13.72 2537 6 6
6 873.32 15 14.11 1643 6 6
7 418.96 16 14.42 1013 6 6
8 84.64 15 14.81 486 6 6
9 0.96 190 14.55 330 6 21

Cycle 11 GMT 28/10/2013 19:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.76 28 14.87 461 6 6
2 2006.00 29 13.50 3350 6 6
3 1924.88 16 13.40 3235 6 6
4 1817.24 16 13.51 3049 6 6
5 1458.72 16 13.70 2521 6 6
6 877.00 16 14.08 1631 6 6
7 412.72 16 14.44 1007 6 6
8 80.60 15 14.86 467 6 6
9 0.92 16 14.94 334 6 6
10 0.12 190 14.52 326 6 23

Cycle 10 GMT 18/10/2013 19:34:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 28 14.87 480 6 6
2 2002.36 70 13.01 3304 6 6
3 1047.88 24 13.86 1882 6 6
4 585.44 24 14.19 1222 6 6
5 58.00 24 14.81 436 6 6
6 0.00 200 14.52 326 6 23

Cycle 9 GMT 8/10/2013 19:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 28 14.87 480 6 6
2 2004.28 70 13.04 3292 6 6
3 1055.72 25 13.82 1888 6 6
4 375.56 24 14.42 930 6 6
5 26.52 24 14.87 378 6 6
6 0.12 201 14.54 328 6 21

Cycle 8 GMT 28/ 9/2013 20:10: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.04 28 14.87 461 6 6
2 2003.64 70 13.03 3303 6 6
3 1034.76 25 13.84 1859 6 6
4 356.56 25 14.42 901 6 6
5 26.00 24 14.88 376 6 6
6 0.12 201 14.53 326 6 25

Cycle 7 GMT 18/ 9/2013 20:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.24 28 14.80 500 6 6
2 2000.44 70 13.01 3301 6 6
3 1258.52 25 13.69 2199 6 6
4 317.24 24 14.49 855 6 6
5 59.20 24 14.85 426 6 6
6 0.00 201 14.55 327 6 25

Cycle 6 GMT 8/ 9/2013 21: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 25 14.87 500 6 6
2 1091.04 2 14.68 2038 6 6
3 1019.28 1 14.68 2000 6 6
4 1443.84 70 13.36 2465 6 6
5 793.68 24 13.99 1549 6 6
6 175.52 25 14.67 622 6 6
7 0.20 201 14.55 332 6 21

Cycle 5 GMT 29/ 8/2013 21:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.12 30 14.80 500 6 6
2 894.40 -2 14.80 500 6 6
3 956.48 -1 14.80 500 6 6
4 1958.68 70 13.02 3235 6 6
5 1191.32 25 13.68 2097 6 6
6 266.40 25 14.54 774 6 6
7 0.16 201 14.57 332 6 18

Cycle 4 GMT 19/ 8/2013 20:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.24 27 14.80 500 6 6
2 1510.04 70 13.31 2587 6 6
3 821.48 24 13.98 1545 6 6
4 175.60 24 14.68 622 6 6
5 0.16 251 14.51 334 6 46

Cycle 3 GMT 18/ 8/2013 21:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 27 14.74 480 6 6
2 1502.88 70 13.28 2576 6 6
3 832.80 25 13.92 1572 6 6
4 175.12 24 14.65 624 6 6
5 0.12 251 14.49 338 6 43

Cycle 2 GMT 17/ 8/2013 21:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.76 27 14.74 480 6 6
2 1512.68 70 13.19 2603 6 6
3 1034.32 25 13.75 1874 6 6
4 315.92 25 14.38 855 6 6
5 0.12 251 14.45 338 6 41

Cycle 1 GMT 16/ 8/2013 22:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.68 24 14.80 461 6 6
2 1097.40 2 14.23 2115 6 6
3 1045.64 1 14.36 1980 6 6
4 1018.00 70 13.44 1841 6 6
5 95.20 25 14.63 495 6 6
6 0.08 251 14.41 333 6 58

Cycle 0 GMT 16/ 8/2013 10:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 138.36 70 14.39 500 232 6
2 99.96 24 14.72 447 6 6
3 0.40 251 14.59 294 6 25