SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.36 | 46 | 10.22 | 517 | 6 | 6 |
2 | 983.60 | 75 | 7.10 | 1682 | 6 | 6 |
3 | 509.76 | 48 | 8.62 | 1098 | 6 | 7 |
4 | 33.12 | 49 | 10.27 | 410 | 6 | 8 |
5 | -0.08 | 181 | 10.42 | 364 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.28 | 46 | 10.15 | 517 | 6 | 6 |
2 | 991.32 | 75 | 7.20 | 1688 | 6 | 6 |
3 | 668.20 | 49 | 8.24 | 1299 | 6 | 7 |
4 | 0.12 | 181 | 10.46 | 358 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.60 | 45 | 10.15 | 553 | 6 | 6 |
2 | 1022.80 | 75 | 7.17 | 1739 | 6 | 6 |
3 | 687.36 | 48 | 8.31 | 1310 | 6 | 7 |
4 | 15.80 | 48 | 10.50 | 350 | 6 | 8 |
5 | -0.24 | 181 | 10.52 | 353 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.28 | 45 | 10.15 | 535 | 6 | 6 |
2 | 1026.12 | 1 | 7.98 | 1714 | 6 | 6 |
3 | 1145.28 | 40 | 7.02 | 1947 | 6 | 6 |
4 | 1594.24 | 130 | 5.79 | 2592 | 6 | 6 |
5 | 1582.64 | 75 | 5.81 | 2575 | 6 | 6 |
6 | 854.24 | 49 | 7.83 | 1576 | 6 | 6 |
7 | 142.04 | 49 | 9.99 | 576 | 6 | 8 |
8 | 0.00 | 181 | 10.48 | 371 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.08 | 46 | 10.15 | 535 | 6 | 6 |
2 | 1028.40 | 1 | 7.47 | 1785 | 6 | 6 |
3 | 1011.44 | 75 | 7.24 | 1725 | 6 | 6 |
4 | 538.32 | 49 | 8.75 | 1101 | 6 | 7 |
5 | 0.28 | 181 | 10.51 | 359 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.32 | 45 | 10.09 | 553 | 6 | 6 |
2 | 1036.52 | 1 | 7.98 | 1785 | 6 | 6 |
3 | 1038.44 | 75 | 7.23 | 1764 | 6 | 6 |
4 | 712.00 | 49 | 8.31 | 1351 | 6 | 7 |
5 | 73.16 | 49 | 10.22 | 474 | 6 | 9 |
6 | 0.16 | 181 | 10.50 | 357 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.40 | 45 | 10.22 | 517 | 6 | 6 |
2 | 1014.52 | 75 | 7.37 | 1728 | 6 | 6 |
3 | 671.84 | 49 | 8.41 | 1321 | 6 | 6 |
4 | 56.44 | 49 | 10.28 | 440 | 6 | 8 |
5 | -0.08 | 181 | 10.52 | 362 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 45 | 10.28 | 517 | 6 | 6 |
2 | 1127.00 | 40 | 7.31 | 1905 | 6 | 6 |
3 | 1568.36 | 130 | 6.19 | 2536 | 6 | 6 |
4 | 1554.88 | 75 | 6.12 | 2530 | 6 | 6 |
5 | 596.68 | 49 | 8.72 | 1216 | 6 | 7 |
6 | 0.16 | 180 | 10.56 | 357 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 46 | 10.22 | 535 | 6 | 6 |
2 | 1012.80 | 75 | 7.34 | 1739 | 6 | 6 |
3 | 670.64 | 49 | 8.40 | 1309 | 6 | 7 |
4 | 55.88 | 49 | 10.27 | 443 | 6 | 8 |
5 | 0.52 | 180 | 10.50 | 364 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.24 | 45 | 10.22 | 500 | 6 | 6 |
2 | 968.96 | -1 | 10.22 | 500 | 6 | 6 |
3 | 1017.80 | 75 | 7.41 | 1745 | 6 | 6 |
4 | 686.92 | 49 | 8.45 | 1340 | 6 | 7 |
5 | 29.08 | 49 | 10.42 | 394 | 6 | 8 |
6 | 0.00 | 181 | 10.54 | 358 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.88 | 45 | 10.28 | 553 | 6 | 6 |
2 | 1016.76 | 75 | 7.51 | 1743 | 6 | 6 |
3 | 680.56 | 48 | 8.56 | 1301 | 6 | 7 |
4 | 58.00 | 48 | 10.38 | 428 | 6 | 7 |
5 | -0.08 | 181 | 10.57 | 350 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.44 | 44 | 10.28 | 535 | 6 | 6 |
2 | 1030.24 | 1 | 8.05 | 1750 | 6 | 6 |
3 | 1140.84 | 40 | 7.40 | 1945 | 6 | 6 |
4 | 1560.96 | 130 | 6.37 | 2538 | 6 | 6 |
5 | 1545.44 | 75 | 6.40 | 2494 | 6 | 6 |
6 | 400.64 | 49 | 9.34 | 953 | 6 | 7 |
7 | 0.28 | 181 | 10.55 | 362 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.76 | 46 | 10.35 | 535 | 6 | 6 |
2 | 972.24 | -1 | 10.35 | 535 | 6 | 6 |
3 | 1015.12 | 75 | 7.54 | 1735 | 6 | 6 |
4 | 666.36 | 49 | 8.53 | 1324 | 6 | 7 |
5 | 2.20 | 49 | 10.58 | 361 | 6 | 8 |
6 | 0.00 | 180 | 10.55 | 363 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.76 | 45 | 10.28 | 535 | 6 | 6 |
2 | 1015.24 | 75 | 7.56 | 1736 | 6 | 6 |
3 | 521.20 | 48 | 8.98 | 1120 | 6 | 7 |
4 | 0.00 | 181 | 10.55 | 368 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.72 | 46 | 10.35 | 517 | 6 | 6 |
2 | 955.92 | -1 | 10.35 | 517 | 6 | 6 |
3 | 1000.52 | 75 | 7.66 | 1725 | 6 | 6 |
4 | 503.56 | 48 | 9.05 | 1087 | 6 | 7 |
5 | 0.32 | 181 | 10.57 | 361 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.72 | 45 | 10.03 | 571 | 6 | 6 |
2 | 981.36 | -1 | 10.03 | 571 | 6 | 6 |
3 | 1133.48 | 38 | 7.51 | 1937 | 6 | 6 |
4 | 1585.92 | 130 | 6.52 | 2537 | 6 | 6 |
5 | 1571.68 | 75 | 6.48 | 2558 | 6 | 6 |
6 | 397.32 | 48 | 9.40 | 945 | 6 | 7 |
7 | 0.16 | 181 | 10.59 | 360 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.88 | 46 | 10.35 | 535 | 6 | 6 |
2 | 1039.48 | 75 | 7.62 | 1758 | 6 | 6 |
3 | 704.44 | 48 | 8.64 | 1345 | 6 | 7 |
4 | 15.24 | 49 | 10.50 | 377 | 6 | 7 |
5 | 0.16 | 181 | 10.57 | 361 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.04 | 46 | 9.96 | 571 | 6 | 6 |
2 | 987.48 | 75 | 7.74 | 1710 | 6 | 6 |
3 | 485.44 | 48 | 9.15 | 1069 | 6 | 7 |
4 | -0.12 | 181 | 10.56 | 372 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 46 | 10.35 | 535 | 6 | 6 |
2 | 1001.36 | 75 | 7.86 | 1713 | 6 | 6 |
3 | 494.08 | 49 | 9.21 | 1077 | 6 | 7 |
4 | 0.20 | 181 | 10.60 | 358 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.76 | 45 | 10.35 | 535 | 6 | 6 |
2 | 1118.68 | 35 | 7.70 | 1906 | 6 | 6 |
3 | 1588.44 | 130 | 6.72 | 2586 | 6 | 6 |
4 | 1571.88 | 75 | 6.64 | 2568 | 6 | 6 |
5 | 379.96 | 49 | 9.53 | 929 | 6 | 7 |
6 | 0.16 | 181 | 10.63 | 360 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.40 | 47 | 10.35 | 535 | 6 | 6 |
2 | 945.88 | -2 | 10.35 | 535 | 6 | 6 |
3 | 1023.88 | 75 | 7.77 | 1758 | 6 | 6 |
4 | 677.28 | 48 | 8.78 | 1325 | 6 | 7 |
5 | 0.00 | 181 | 10.60 | 367 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.60 | 45 | 10.35 | 535 | 6 | 6 |
2 | 1028.88 | 75 | 7.83 | 1752 | 6 | 6 |
3 | 682.76 | 48 | 8.76 | 1307 | 6 | 7 |
4 | 0.20 | 181 | 10.60 | 368 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.00 | 45 | 10.41 | 517 | 6 | 6 |
2 | 1023.76 | 75 | 7.88 | 1758 | 6 | 6 |
3 | 525.68 | 48 | 9.18 | 1121 | 6 | 7 |
4 | 7.80 | 49 | 10.57 | 376 | 6 | 7 |
5 | 0.12 | 181 | 10.59 | 376 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 44 | 10.35 | 553 | 6 | 6 |
2 | 1114.08 | 60 | 7.84 | 1937 | 6 | 6 |
3 | 1132.96 | 130 | 7.85 | 1949 | 6 | 6 |
4 | 1113.12 | 75 | 7.89 | 1919 | 6 | 6 |
5 | 0.24 | 181 | 10.66 | 361 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.16 | 44 | 10.41 | 517 | 6 | 6 |
2 | 1038.08 | 3 | 8.30 | 1785 | 6 | 6 |
3 | 1047.44 | 1 | 8.11 | 1857 | 6 | 6 |
4 | 1034.84 | 75 | 7.90 | 1769 | 6 | 6 |
5 | 528.80 | 48 | 9.24 | 1102 | 6 | 7 |
6 | 24.16 | 49 | 10.56 | 401 | 6 | 6 |
7 | -0.20 | 181 | 10.61 | 365 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 47 | 10.28 | 553 | 6 | 6 |
2 | 875.92 | -3 | 10.28 | 553 | 6 | 6 |
3 | 1002.08 | 75 | 8.00 | 1728 | 6 | 6 |
4 | 647.84 | 48 | 8.94 | 1308 | 6 | 7 |
5 | 0.64 | 181 | 10.61 | 372 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.20 | 46 | 10.28 | 535 | 6 | 6 |
2 | 1048.96 | 1 | 8.37 | 1803 | 6 | 6 |
3 | 1069.44 | 75 | 7.90 | 1829 | 6 | 6 |
4 | 573.52 | 46 | 9.20 | 1166 | 6 | 7 |
5 | 0.56 | 181 | 10.64 | 364 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.92 | 45 | 10.28 | 553 | 6 | 6 |
2 | 956.68 | -1 | 10.28 | 553 | 6 | 6 |
3 | 1223.64 | 24 | 7.51 | 2267 | 6 | 6 |
4 | 1887.76 | 130 | 6.35 | 3026 | 6 | 6 |
5 | 1873.84 | 75 | 5.98 | 3066 | 6 | 6 |
6 | 1156.24 | 45 | 7.96 | 1981 | 6 | 6 |
7 | 455.84 | 45 | 9.43 | 1053 | 6 | 7 |
8 | -0.08 | 181 | 10.65 | 368 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 44 | 10.35 | 535 | 6 | 6 |
2 | 957.48 | -1 | 10.35 | 535 | 6 | 6 |
3 | 1018.52 | 75 | 8.05 | 1773 | 6 | 6 |
4 | 503.72 | 46 | 9.30 | 1105 | 6 | 7 |
5 | -0.16 | 181 | 10.60 | 378 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.48 | 46 | 10.41 | 517 | 6 | 6 |
2 | 1028.68 | 1 | 8.56 | 1750 | 6 | 6 |
3 | 1032.56 | 75 | 8.09 | 1782 | 6 | 6 |
4 | 526.04 | 46 | 9.32 | 1117 | 6 | 7 |
5 | 10.92 | 45 | 10.57 | 392 | 6 | 7 |
6 | 0.36 | 181 | 10.62 | 375 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.24 | 45 | 10.41 | 553 | 6 | 6 |
2 | 993.68 | 75 | 8.21 | 1732 | 6 | 7 |
3 | 621.72 | 46 | 9.16 | 1245 | 6 | 7 |
4 | 37.84 | 45 | 10.53 | 426 | 6 | 7 |
5 | -0.24 | 181 | 10.62 | 377 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.44 | 44 | 10.47 | 553 | 6 | 6 |
2 | 1071.52 | 1 | 8.81 | 1785 | 6 | 6 |
3 | 1170.28 | 16 | 8.16 | 1999 | 6 | 6 |
4 | 1904.20 | 130 | 6.61 | 3052 | 6 | 6 |
5 | 1892.96 | 75 | 6.02 | 3077 | 6 | 6 |
6 | 1137.48 | 45 | 8.16 | 1963 | 6 | 6 |
7 | 766.32 | 45 | 8.93 | 1473 | 6 | 7 |
8 | 26.16 | 45 | 10.61 | 411 | 6 | 7 |
9 | 0.16 | 181 | 10.67 | 377 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.00 | 45 | 10.47 | 535 | 6 | 6 |
2 | 961.80 | -1 | 10.47 | 535 | 6 | 6 |
3 | 976.32 | 75 | 8.36 | 1724 | 6 | 6 |
4 | 796.28 | 46 | 8.88 | 1511 | 6 | 7 |
5 | 0.40 | 181 | 10.70 | 365 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 45 | 10.47 | 553 | 6 | 6 |
2 | 990.04 | 75 | 8.45 | 1720 | 6 | 6 |
3 | 620.24 | 45 | 9.24 | 1275 | 6 | 7 |
4 | 15.76 | 45 | 10.67 | 386 | 6 | 6 |
5 | -0.08 | 181 | 10.70 | 367 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.76 | 45 | 10.54 | 535 | 6 | 6 |
2 | 1148.12 | 131 | 8.21 | 1949 | 6 | 6 |
3 | 1143.52 | 31 | 8.19 | 1962 | 6 | 6 |
4 | 548.96 | 46 | 9.48 | 1176 | 6 | 7 |
5 | 0.16 | 181 | 10.72 | 373 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.52 | 43 | 10.47 | 553 | 6 | 6 |
2 | 1051.04 | 1 | 8.56 | 1857 | 6 | 6 |
3 | 1154.12 | 10 | 8.43 | 1946 | 6 | 6 |
4 | 1959.84 | 130 | 6.51 | 3137 | 6 | 6 |
5 | 1947.04 | 31 | 5.90 | 3209 | 6 | 6 |
6 | 1611.28 | 46 | 7.51 | 2661 | 6 | 6 |
7 | 1081.12 | 46 | 8.55 | 1885 | 6 | 6 |
8 | 510.60 | 46 | 9.61 | 1133 | 6 | 7 |
9 | 0.00 | 181 | 10.75 | 363 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.28 | 39 | 10.60 | 517 | 6 | 6 |
2 | 1016.08 | 4 | 8.81 | 1857 | 6 | 6 |
3 | 1099.80 | 2 | 9.13 | 1839 | 6 | 6 |
4 | 1187.52 | 131 | 8.10 | 1995 | 6 | 6 |
5 | 1183.56 | 31 | 8.02 | 1992 | 6 | 6 |
6 | 439.52 | 46 | 9.72 | 990 | 6 | 7 |
7 | 0.00 | 180 | 10.72 | 365 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.16 | 39 | 10.66 | 535 | 6 | 6 |
2 | 1016.68 | 4 | 9.20 | 1821 | 6 | 6 |
3 | 1095.20 | 2 | 9.26 | 1892 | 6 | 6 |
4 | 1172.88 | 130 | 8.44 | 1973 | 6 | 6 |
5 | 1166.64 | 30 | 8.32 | 1970 | 6 | 6 |
6 | 375.04 | 45 | 9.92 | 899 | 6 | 8 |
7 | 0.16 | 181 | 10.75 | 364 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.64 | 39 | 11.05 | 535 | 6 | 6 |
2 | 1140.52 | 130 | 8.89 | 1950 | 6 | 6 |
3 | 1134.08 | 31 | 8.64 | 1938 | 6 | 6 |
4 | 134.48 | 45 | 10.61 | 566 | 6 | 8 |
5 | 0.32 | 181 | 10.86 | 365 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.32 | 37 | 11.24 | 553 | 6 | 6 |
2 | 1014.40 | 3 | 10.15 | 1785 | 6 | 6 |
3 | 1031.28 | 4 | 10.15 | 1857 | 6 | 6 |
4 | 944.28 | -2 | 10.15 | 1857 | 6 | 6 |
5 | 1116.88 | 10 | 9.81 | 2004 | 6 | 6 |
6 | 1924.96 | 130 | 7.40 | 3058 | 6 | 6 |
7 | 1907.24 | 31 | 6.40 | 3110 | 6 | 6 |
8 | 1131.00 | 45 | 9.13 | 1980 | 6 | 7 |
9 | 353.88 | 45 | 10.53 | 875 | 6 | 7 |
10 | 0.00 | 181 | 11.16 | 372 | 10 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.00 | 35 | 11.62 | 553 | 6 | 6 |
2 | 1023.00 | 3 | 10.92 | 1875 | 6 | 6 |
3 | 1066.84 | 1 | 10.79 | 1857 | 6 | 6 |
4 | 1161.16 | 130 | 8.14 | 1951 | 6 | 6 |
5 | 1155.72 | 30 | 8.28 | 1933 | 6 | 6 |
6 | 563.24 | 45 | 10.18 | 1176 | 6 | 8 |
7 | 152.28 | 45 | 11.09 | 595 | 6 | 9 |
8 | 0.04 | 181 | 11.38 | 368 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.12 | 39 | 12.19 | 553 | 6 | 6 |
2 | 978.80 | -1 | 12.19 | 553 | 6 | 6 |
3 | 1118.80 | 130 | 8.85 | 1928 | 6 | 6 |
4 | 1116.88 | 31 | 8.96 | 1959 | 6 | 6 |
5 | 136.16 | 45 | 11.72 | 583 | 6 | 9 |
6 | 0.04 | 181 | 11.82 | 374 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.24 | 34 | 12.19 | 535 | 6 | 6 |
2 | 1031.48 | 3 | 11.56 | 1875 | 6 | 6 |
3 | 1110.28 | 2 | 11.30 | 2000 | 6 | 6 |
4 | 1102.08 | 31 | 10.81 | 1941 | 6 | 6 |
5 | 940.48 | 46 | 10.99 | 1730 | 6 | 8 |
6 | 158.24 | 46 | 12.19 | 600 | 6 | 8 |
7 | 0.08 | 181 | 12.25 | 377 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.28 | 33 | 12.51 | 571 | 6 | 6 |
2 | 1020.88 | 3 | 11.30 | 1928 | 6 | 6 |
3 | 1078.36 | 1 | 11.43 | 1946 | 6 | 6 |
4 | 1164.24 | 10 | 11.00 | 2022 | 6 | 6 |
5 | 1933.76 | 130 | 7.57 | 3101 | 6 | 6 |
6 | 1919.96 | 30 | 6.52 | 3211 | 6 | 6 |
7 | 1141.64 | 45 | 10.12 | 1986 | 6 | 7 |
8 | 159.92 | 46 | 11.98 | 594 | 6 | 7 |
9 | -0.04 | 181 | 12.10 | 370 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.60 | 34 | 12.95 | 553 | 6 | 6 |
2 | 1105.48 | 130 | 7.52 | 1862 | 6 | 6 |
3 | 1103.20 | 30 | 9.27 | 1901 | 6 | 6 |
4 | 531.00 | 45 | 11.37 | 1134 | 6 | 8 |
5 | 0.40 | 181 | 12.48 | 383 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.08 | 34 | 13.34 | 553 | 6 | 6 |
2 | 1127.72 | 130 | 7.55 | 1894 | 6 | 6 |
3 | 1131.56 | 31 | 9.57 | 1941 | 6 | 6 |
4 | 240.76 | 45 | 12.76 | 721 | 6 | 10 |
5 | 0.00 | 181 | 12.96 | 383 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.48 | 34 | 13.65 | 535 | 6 | 6 |
2 | 1151.72 | 130 | 7.44 | 1954 | 6 | 6 |
3 | 1152.52 | 31 | 9.44 | 2008 | 6 | 6 |
4 | 598.88 | 46 | 11.97 | 1232 | 6 | 8 |
5 | 0.12 | 181 | 13.21 | 382 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.72 | 34 | 13.72 | 535 | 6 | 6 |
2 | 923.68 | -2 | 13.72 | 535 | 6 | 6 |
3 | 1131.68 | 11 | 11.50 | 2028 | 6 | 6 |
4 | 1874.88 | 130 | 8.82 | 3020 | 6 | 6 |
5 | 1858.24 | 31 | 9.43 | 2981 | 6 | 6 |
6 | 353.92 | 45 | 13.08 | 861 | 6 | 9 |
7 | 0.08 | 181 | 13.47 | 379 | 7 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.56 | 34 | 13.91 | 535 | 6 | 6 |
2 | 1130.96 | 131 | 6.14 | 1887 | 6 | 6 |
3 | 1138.72 | 31 | 9.11 | 1973 | 6 | 6 |
4 | 981.76 | 46 | 10.20 | 1767 | 6 | 7 |
5 | 86.04 | 45 | 13.67 | 501 | 6 | 7 |
6 | 0.20 | 181 | 13.60 | 376 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.04 | 35 | 13.85 | 571 | 6 | 6 |
2 | 939.68 | -2 | 13.85 | 571 | 6 | 6 |
3 | 1115.04 | 131 | 6.68 | 1882 | 6 | 6 |
4 | 1120.68 | 31 | 9.22 | 1959 | 6 | 6 |
5 | 953.68 | 45 | 10.41 | 1761 | 6 | 7 |
6 | -0.16 | 181 | 13.74 | 381 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.92 | 36 | 14.10 | 535 | 6 | 6 |
2 | 910.88 | -2 | 14.10 | 535 | 6 | 6 |
3 | 1130.16 | 130 | 7.66 | 1919 | 6 | 6 |
4 | 1131.76 | 31 | 9.56 | 1991 | 6 | 6 |
5 | 542.68 | 45 | 12.83 | 1135 | 6 | 9 |
6 | 0.08 | 181 | 13.85 | 376 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 34 | 13.72 | 589 | 6 | 6 |
2 | 1171.88 | 10 | 11.31 | 2057 | 6 | 6 |
3 | 1914.56 | 130 | 8.90 | 3071 | 6 | 6 |
4 | 1899.12 | 31 | 9.64 | 3032 | 6 | 7 |
5 | 377.60 | 45 | 13.50 | 894 | 6 | 9 |
6 | 0.24 | 181 | 13.95 | 376 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.32 | 34 | 14.04 | 553 | 6 | 6 |
2 | 1143.44 | 131 | 6.84 | 1904 | 6 | 6 |
3 | 1146.24 | 31 | 9.39 | 1938 | 6 | 6 |
4 | 788.04 | 45 | 12.07 | 1492 | 6 | 8 |
5 | 7.32 | 45 | 14.10 | 384 | 6 | 15 |
6 | 0.12 | 181 | 13.84 | 380 | 6 | 42 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 34 | 13.91 | 571 | 6 | 6 |
2 | 1017.76 | 3 | 12.51 | 1875 | 6 | 6 |
3 | 1156.04 | 130 | 7.52 | 1935 | 6 | 6 |
4 | 1159.00 | 31 | 9.43 | 2020 | 6 | 6 |
5 | 606.28 | 46 | 12.79 | 1227 | 6 | 9 |
6 | 0.04 | 181 | 13.94 | 374 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.40 | 34 | 14.10 | 535 | 6 | 6 |
2 | 977.76 | -1 | 14.10 | 535 | 6 | 6 |
3 | 1173.56 | 111 | 8.18 | 1996 | 6 | 6 |
4 | 1174.92 | 31 | 9.80 | 2039 | 6 | 6 |
5 | 621.16 | 46 | 12.84 | 1260 | 6 | 9 |
6 | 0.24 | 181 | 13.99 | 379 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.92 | 34 | 14.17 | 535 | 6 | 6 |
2 | 1145.76 | 10 | 11.38 | 2071 | 6 | 6 |
3 | 1917.16 | 111 | 9.41 | 3082 | 6 | 6 |
4 | 1904.72 | 31 | 9.81 | 3057 | 6 | 6 |
5 | 634.28 | 45 | 13.18 | 1268 | 6 | 10 |
6 | -0.08 | 181 | 13.99 | 386 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.84 | 34 | 14.10 | 535 | 6 | 6 |
2 | 1186.52 | 111 | 7.18 | 1971 | 6 | 6 |
3 | 1191.56 | 31 | 9.36 | 2058 | 6 | 6 |
4 | 1018.36 | 45 | 11.32 | 1846 | 6 | 7 |
5 | 37.92 | 45 | 14.05 | 438 | 6 | 11 |
6 | 0.08 | 181 | 13.99 | 389 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 34 | 14.10 | 553 | 6 | 6 |
2 | 1157.28 | 111 | 7.79 | 1948 | 6 | 6 |
3 | 1160.88 | 31 | 9.45 | 2037 | 6 | 7 |
4 | 807.20 | 46 | 12.30 | 1527 | 6 | 8 |
5 | 0.16 | 180 | 13.97 | 378 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.12 | 34 | 13.85 | 571 | 6 | 6 |
2 | 1169.48 | 111 | 8.40 | 1983 | 6 | 6 |
3 | 1170.04 | 31 | 9.86 | 2044 | 6 | 7 |
4 | 433.84 | 46 | 13.40 | 980 | 6 | 9 |
5 | 0.08 | 180 | 13.97 | 392 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 34 | 14.10 | 535 | 6 | 6 |
2 | 1167.04 | 10 | 11.31 | 2048 | 6 | 6 |
3 | 1897.92 | 111 | 9.58 | 3042 | 6 | 6 |
4 | 1884.36 | 31 | 9.74 | 3068 | 6 | 6 |
5 | 409.36 | 45 | 13.55 | 951 | 6 | 10 |
6 | 0.32 | 180 | 14.01 | 384 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.76 | 34 | 13.91 | 571 | 6 | 6 |
2 | 1177.32 | 111 | 7.28 | 1960 | 6 | 6 |
3 | 1182.72 | 31 | 9.48 | 2013 | 6 | 6 |
4 | 837.80 | 45 | 12.26 | 1568 | 6 | 8 |
5 | 34.60 | 45 | 14.07 | 441 | 6 | 12 |
6 | 0.08 | 181 | 13.99 | 390 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 34 | 14.04 | 571 | 6 | 6 |
2 | 1166.56 | 111 | 7.83 | 1972 | 6 | 6 |
3 | 1168.80 | 31 | 9.59 | 2026 | 6 | 7 |
4 | 798.48 | 46 | 12.43 | 1513 | 6 | 9 |
5 | 22.48 | 45 | 14.08 | 420 | 6 | 12 |
6 | 0.16 | 180 | 14.03 | 380 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 34 | 13.91 | 589 | 6 | 6 |
2 | 1148.84 | 111 | 8.40 | 1968 | 6 | 6 |
3 | 1151.40 | 31 | 9.94 | 2040 | 6 | 7 |
4 | 594.92 | 46 | 13.09 | 1212 | 6 | 9 |
5 | 0.04 | 181 | 13.99 | 391 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.40 | 34 | 13.97 | 553 | 6 | 6 |
2 | 1155.76 | 11 | 11.37 | 2078 | 6 | 6 |
3 | 1863.24 | 111 | 9.47 | 3006 | 6 | 6 |
4 | 1850.84 | 31 | 9.88 | 2967 | 6 | 7 |
5 | 379.80 | 45 | 13.57 | 923 | 6 | 10 |
6 | 0.28 | 181 | 14.00 | 395 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.96 | 34 | 14.10 | 553 | 6 | 6 |
2 | 1163.84 | 111 | 7.14 | 1952 | 6 | 6 |
3 | 1168.44 | 31 | 9.45 | 2036 | 6 | 6 |
4 | 997.96 | 45 | 11.68 | 1798 | 6 | 7 |
5 | 27.88 | 45 | 14.08 | 432 | 6 | 11 |
6 | 0.12 | 181 | 14.01 | 388 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.00 | 34 | 14.10 | 553 | 6 | 6 |
2 | 1159.64 | 111 | 7.67 | 1968 | 6 | 6 |
3 | 1163.56 | 31 | 9.59 | 2043 | 6 | 6 |
4 | 799.24 | 46 | 12.47 | 1509 | 6 | 8 |
5 | 0.04 | 181 | 13.99 | 393 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.00 | 34 | 14.10 | 553 | 6 | 6 |
2 | 1144.00 | 111 | 8.28 | 1939 | 6 | 6 |
3 | 1145.76 | 31 | 9.97 | 1997 | 6 | 7 |
4 | 768.80 | 45 | 12.67 | 1464 | 6 | 9 |
5 | 3.00 | 45 | 14.11 | 397 | 6 | 12 |
6 | 0.04 | 180 | 13.99 | 394 | 6 | 41 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.92 | 35 | 14.10 | 535 | 6 | 6 |
2 | 964.20 | -1 | 14.10 | 535 | 6 | 6 |
3 | 1151.72 | 10 | 11.46 | 2039 | 6 | 6 |
4 | 1903.20 | 111 | 9.24 | 3057 | 6 | 6 |
5 | 1889.84 | 31 | 9.82 | 3048 | 6 | 6 |
6 | 617.04 | 45 | 13.29 | 1233 | 6 | 10 |
7 | 0.00 | 181 | 14.04 | 389 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.88 | 34 | 14.10 | 535 | 6 | 6 |
2 | 1169.20 | 111 | 7.07 | 1947 | 6 | 6 |
3 | 1174.52 | 31 | 9.61 | 1969 | 6 | 6 |
4 | 847.48 | 45 | 12.34 | 1554 | 6 | 8 |
5 | 34.32 | 45 | 14.06 | 421 | 6 | 10 |
6 | 0.08 | 181 | 14.02 | 379 | 6 | 42 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.72 | 34 | 14.04 | 553 | 6 | 6 |
2 | 1158.56 | 111 | 7.63 | 1945 | 6 | 6 |
3 | 1162.52 | 31 | 9.54 | 2046 | 6 | 6 |
4 | 801.92 | 45 | 12.48 | 1510 | 6 | 8 |
5 | 1.00 | 181 | 14.04 | 378 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.28 | 34 | 13.97 | 553 | 6 | 6 |
2 | 1156.64 | 106 | 8.15 | 1962 | 6 | 6 |
3 | 1159.12 | 31 | 9.89 | 2024 | 6 | 7 |
4 | 793.08 | 40 | 12.68 | 1494 | 6 | 8 |
5 | 0.12 | 180 | 14.03 | 389 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.60 | 35 | 13.97 | 553 | 6 | 6 |
2 | 959.12 | -1 | 13.97 | 553 | 6 | 6 |
3 | 1143.52 | 10 | 11.31 | 2053 | 6 | 6 |
4 | 1917.92 | 106 | 9.19 | 3068 | 6 | 6 |
5 | 1905.12 | 31 | 9.87 | 3053 | 6 | 6 |
6 | 673.20 | 41 | 13.26 | 1315 | 6 | 9 |
7 | -0.04 | 181 | 14.07 | 382 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.56 | 34 | 14.04 | 571 | 6 | 6 |
2 | 976.40 | -1 | 14.04 | 571 | 6 | 6 |
3 | 1176.24 | 106 | 6.94 | 1960 | 6 | 6 |
4 | 1182.44 | 31 | 9.40 | 2070 | 6 | 6 |
5 | 1023.00 | 40 | 11.87 | 1823 | 6 | 8 |
6 | 239.52 | 40 | 13.73 | 751 | 6 | 12 |
7 | 0.24 | 181 | 14.02 | 383 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.16 | 34 | 13.97 | 553 | 6 | 6 |
2 | 1167.12 | 106 | 7.33 | 1955 | 6 | 6 |
3 | 1171.84 | 31 | 9.54 | 2034 | 6 | 6 |
4 | 996.72 | 40 | 11.92 | 1798 | 6 | 8 |
5 | 13.60 | 41 | 14.11 | 402 | 6 | 9 |
6 | -0.08 | 181 | 14.00 | 388 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.20 | 34 | 14.04 | 535 | 6 | 6 |
2 | 1139.20 | 101 | 8.08 | 1943 | 6 | 6 |
3 | 1144.92 | 31 | 9.95 | 2016 | 6 | 6 |
4 | 800.80 | 25 | 12.92 | 1535 | 6 | 9 |
5 | 238.20 | 25 | 13.81 | 739 | 6 | 10 |
6 | 0.16 | 181 | 14.03 | 385 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.96 | 35 | 14.10 | 553 | 6 | 6 |
2 | 1169.28 | 10 | 11.28 | 2035 | 6 | 6 |
3 | 1910.48 | 100 | 9.09 | 3066 | 6 | 6 |
4 | 1898.24 | 31 | 9.82 | 3109 | 6 | 6 |
5 | 877.88 | 25 | 13.21 | 1612 | 6 | 11 |
6 | 58.44 | 25 | 14.12 | 474 | 6 | 10 |
7 | 0.20 | 181 | 14.15 | 383 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.96 | 34 | 13.97 | 571 | 6 | 6 |
2 | 1158.56 | 101 | 6.75 | 1932 | 6 | 6 |
3 | 1164.68 | 31 | 9.47 | 2023 | 6 | 6 |
4 | 1022.56 | 25 | 12.10 | 1855 | 6 | 8 |
5 | 851.00 | 25 | 12.71 | 1579 | 6 | 9 |
6 | 3.08 | 25 | 14.15 | 383 | 6 | 10 |
7 | 0.16 | 180 | 14.12 | 379 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.80 | 34 | 13.97 | 571 | 6 | 6 |
2 | 1151.36 | 101 | 7.34 | 1921 | 6 | 6 |
3 | 1157.16 | 31 | 9.67 | 2029 | 6 | 6 |
4 | 996.24 | 25 | 12.22 | 1817 | 6 | 8 |
5 | 437.60 | 25 | 13.56 | 997 | 6 | 8 |
6 | 2.32 | 25 | 14.12 | 401 | 6 | 9 |
7 | -0.12 | 180 | 14.00 | 394 | 6 | 38 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.76 | 35 | 14.04 | 553 | 6 | 6 |
2 | 976.28 | -1 | 14.04 | 553 | 6 | 6 |
3 | 1174.12 | 101 | 7.84 | 1979 | 6 | 6 |
4 | 1179.12 | 31 | 9.92 | 2073 | 6 | 7 |
5 | 834.00 | 25 | 12.87 | 1574 | 6 | 9 |
6 | 277.68 | 25 | 13.80 | 792 | 6 | 9 |
7 | 0.08 | 181 | 14.01 | 398 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.48 | 36 | 14.04 | 553 | 6 | 6 |
2 | 929.36 | -2 | 14.04 | 553 | 6 | 6 |
3 | 1148.24 | 10 | 11.20 | 2008 | 6 | 6 |
4 | 1922.40 | 100 | 9.05 | 3072 | 6 | 6 |
5 | 1911.80 | 30 | 9.87 | 3097 | 6 | 7 |
6 | 905.48 | 25 | 13.17 | 1683 | 6 | 9 |
7 | 66.36 | 25 | 14.12 | 480 | 6 | 10 |
8 | 0.28 | 181 | 14.12 | 385 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.12 | 34 | 13.91 | 571 | 6 | 6 |
2 | 1026.92 | 1 | 11.81 | 1857 | 6 | 6 |
3 | 1179.00 | 101 | 6.58 | 1946 | 6 | 6 |
4 | 1185.48 | 31 | 9.60 | 2024 | 6 | 6 |
5 | 1046.28 | 25 | 12.18 | 1876 | 6 | 7 |
6 | 702.88 | 25 | 13.16 | 1372 | 6 | 9 |
7 | 27.72 | 25 | 14.12 | 417 | 6 | 10 |
8 | 0.20 | 181 | 14.13 | 380 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.36 | 35 | 13.97 | 553 | 6 | 6 |
2 | 1170.92 | 101 | 7.26 | 1961 | 6 | 6 |
3 | 1176.52 | 31 | 9.74 | 2060 | 6 | 7 |
4 | 1012.20 | 25 | 12.32 | 1833 | 6 | 9 |
5 | 466.84 | 25 | 13.53 | 1058 | 6 | 8 |
6 | 0.00 | 181 | 14.02 | 395 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.56 | 35 | 13.97 | 571 | 6 | 6 |
2 | 1114.44 | 101 | 8.16 | 1918 | 6 | 6 |
3 | 1119.28 | 31 | 10.12 | 1991 | 6 | 7 |
4 | 950.88 | 25 | 12.49 | 1753 | 6 | 8 |
5 | 172.48 | 25 | 13.90 | 642 | 6 | 9 |
6 | 0.56 | 181 | 13.94 | 407 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 33 | 13.91 | 553 | 6 | 6 |
2 | 1018.60 | 3 | 12.19 | 1857 | 6 | 6 |
3 | 1165.72 | 10 | 11.19 | 2057 | 6 | 6 |
4 | 1932.52 | 100 | 9.19 | 3099 | 6 | 6 |
5 | 1921.64 | 31 | 9.99 | 3083 | 6 | 6 |
6 | 882.24 | 25 | 13.22 | 1624 | 6 | 11 |
7 | 72.48 | 25 | 14.05 | 498 | 6 | 10 |
8 | -0.12 | 181 | 14.08 | 391 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.00 | 34 | 13.91 | 571 | 6 | 6 |
2 | 972.20 | -1 | 13.91 | 571 | 6 | 6 |
3 | 1194.00 | 101 | 6.51 | 1965 | 6 | 6 |
4 | 1203.60 | 31 | 9.69 | 2063 | 6 | 6 |
5 | 1072.76 | 25 | 12.21 | 1942 | 6 | 7 |
6 | 738.04 | 25 | 13.12 | 1419 | 6 | 9 |
7 | 2.36 | 25 | 14.15 | 388 | 6 | 10 |
8 | -0.16 | 180 | 14.09 | 393 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.72 | 34 | 14.04 | 553 | 6 | 6 |
2 | 1058.48 | 1 | 12.12 | 1892 | 6 | 6 |
3 | 1183.00 | 91 | 6.96 | 2009 | 6 | 6 |
4 | 1191.44 | 30 | 9.89 | 2052 | 6 | 6 |
5 | 1052.76 | 25 | 12.46 | 1858 | 6 | 8 |
6 | 710.92 | 25 | 13.25 | 1349 | 6 | 9 |
7 | 147.88 | 25 | 13.92 | 617 | 6 | 10 |
8 | 25.08 | 25 | 14.04 | 435 | 6 | 9 |
9 | 0.28 | 180 | 13.96 | 407 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.04 | 32 | 14.10 | 553 | 6 | 6 |
2 | 1075.88 | 1 | 12.44 | 1946 | 6 | 6 |
3 | 1236.64 | 91 | 7.80 | 2049 | 6 | 6 |
4 | 1241.52 | 30 | 10.18 | 2110 | 6 | 6 |
5 | 1074.72 | 25 | 12.58 | 1892 | 6 | 9 |
6 | 507.32 | 25 | 13.60 | 1087 | 6 | 8 |
7 | 0.16 | 181 | 14.18 | 378 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.00 | 33 | 14.04 | 553 | 6 | 6 |
2 | 1176.36 | 10 | 11.16 | 2057 | 6 | 6 |
3 | 1914.36 | 91 | 9.42 | 3082 | 6 | 6 |
4 | 1904.00 | 31 | 10.09 | 3084 | 6 | 6 |
5 | 712.28 | 25 | 13.38 | 1389 | 6 | 10 |
6 | 171.56 | 25 | 13.91 | 658 | 6 | 10 |
7 | 0.08 | 181 | 14.10 | 388 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 33 | 13.85 | 571 | 6 | 6 |
2 | 1067.32 | 1 | 12.06 | 1964 | 6 | 6 |
3 | 1228.92 | 91 | 5.89 | 2045 | 6 | 6 |
4 | 1239.48 | 31 | 9.57 | 2097 | 6 | 6 |
5 | 1140.16 | 25 | 12.19 | 1976 | 6 | 7 |
6 | 1000.88 | 25 | 12.80 | 1742 | 6 | 9 |
7 | 465.16 | 25 | 13.57 | 1049 | 6 | 10 |
8 | 42.00 | 25 | 14.04 | 460 | 6 | 11 |
9 | 0.04 | 181 | 14.04 | 393 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.24 | 32 | 13.91 | 571 | 6 | 6 |
2 | 1038.76 | 1 | 12.00 | 1910 | 6 | 6 |
3 | 1193.92 | 91 | 6.74 | 2043 | 6 | 6 |
4 | 1202.04 | 31 | 9.86 | 2073 | 6 | 6 |
5 | 1073.48 | 25 | 12.34 | 1915 | 6 | 8 |
6 | 739.28 | 25 | 13.20 | 1399 | 6 | 9 |
7 | 166.60 | 25 | 13.84 | 636 | 6 | 9 |
8 | 0.20 | 181 | 13.93 | 405 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.44 | 32 | 13.78 | 607 | 6 | 6 |
2 | 981.32 | -1 | 13.78 | 607 | 6 | 6 |
3 | 1186.28 | 91 | 7.64 | 1964 | 6 | 6 |
4 | 1189.68 | 31 | 10.05 | 2101 | 6 | 6 |
5 | 863.32 | 25 | 12.99 | 1617 | 6 | 10 |
6 | 330.52 | 25 | 13.66 | 878 | 6 | 9 |
7 | 61.56 | 25 | 14.00 | 503 | 6 | 9 |
8 | 0.12 | 181 | 13.90 | 413 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.60 | 33 | 13.91 | 589 | 6 | 6 |
2 | 1164.68 | 10 | 11.05 | 2106 | 6 | 6 |
3 | 1902.72 | 91 | 9.43 | 3090 | 6 | 6 |
4 | 1891.52 | 31 | 10.10 | 3106 | 6 | 6 |
5 | 1522.88 | 25 | 12.54 | 2547 | 6 | 9 |
6 | 583.76 | 25 | 13.52 | 1204 | 6 | 10 |
7 | 74.56 | 25 | 14.02 | 508 | 6 | 8 |
8 | 0.16 | 181 | 13.88 | 414 | 6 | 38 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.76 | 33 | 13.91 | 589 | 6 | 6 |
2 | 1163.40 | 91 | 6.13 | 1920 | 6 | 6 |
3 | 1171.76 | 30 | 9.76 | 2003 | 6 | 6 |
4 | 1050.24 | 25 | 12.36 | 1888 | 6 | 7 |
5 | 717.12 | 25 | 13.24 | 1385 | 6 | 9 |
6 | 182.16 | 25 | 13.84 | 660 | 6 | 8 |
7 | 12.92 | 25 | 14.04 | 433 | 6 | 8 |
8 | 0.20 | 181 | 13.83 | 413 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.36 | 31 | 13.85 | 571 | 6 | 6 |
2 | 1070.88 | 1 | 12.19 | 1928 | 6 | 6 |
3 | 1231.60 | 91 | 6.69 | 1984 | 6 | 6 |
4 | 1238.12 | 31 | 9.92 | 2100 | 6 | 6 |
5 | 1101.92 | 25 | 12.46 | 1908 | 6 | 7 |
6 | 937.08 | 25 | 12.90 | 1701 | 6 | 9 |
7 | 325.20 | 25 | 13.73 | 840 | 6 | 11 |
8 | 0.12 | 181 | 13.91 | 405 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 32 | 13.91 | 589 | 6 | 6 |
2 | 942.96 | -2 | 13.91 | 589 | 6 | 6 |
3 | 1160.08 | 91 | 7.95 | 1975 | 6 | 6 |
4 | 1165.64 | 31 | 10.29 | 2048 | 6 | 6 |
5 | 987.92 | 25 | 12.72 | 1810 | 6 | 8 |
6 | 410.84 | 25 | 13.62 | 956 | 6 | 9 |
7 | 0.44 | 181 | 13.90 | 410 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.68 | 32 | 13.85 | 571 | 6 | 6 |
2 | 1199.96 | 10 | 11.15 | 2120 | 6 | 6 |
3 | 1869.04 | 91 | 9.35 | 3036 | 6 | 6 |
4 | 1858.24 | 31 | 10.08 | 3041 | 6 | 7 |
5 | 848.60 | 25 | 13.29 | 1544 | 6 | 11 |
6 | 82.48 | 25 | 13.97 | 531 | 6 | 9 |
7 | 14.52 | 25 | 14.01 | 444 | 6 | 9 |
8 | 0.16 | 181 | 13.88 | 410 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.76 | 33 | 13.91 | 589 | 6 | 6 |
2 | 1125.60 | 91 | 6.37 | 1858 | 6 | 6 |
3 | 1133.16 | 31 | 9.80 | 1985 | 6 | 6 |
4 | 1006.36 | 25 | 12.36 | 1842 | 6 | 8 |
5 | 841.32 | 25 | 13.01 | 1529 | 6 | 9 |
6 | 263.16 | 25 | 13.73 | 760 | 6 | 10 |
7 | 40.80 | 25 | 13.97 | 469 | 6 | 8 |
8 | -0.08 | 181 | 13.89 | 409 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.88 | 32 | 13.85 | 571 | 6 | 6 |
2 | 1154.48 | 91 | 7.06 | 1915 | 6 | 6 |
3 | 1160.84 | 31 | 9.98 | 2054 | 6 | 6 |
4 | 1016.36 | 25 | 12.59 | 1833 | 6 | 8 |
5 | 477.96 | 25 | 13.57 | 1045 | 6 | 10 |
6 | 64.12 | 25 | 13.95 | 503 | 6 | 9 |
7 | 0.32 | 181 | 13.88 | 412 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.08 | 32 | 13.91 | 571 | 6 | 6 |
2 | 1148.48 | 91 | 7.91 | 1936 | 6 | 6 |
3 | 1153.16 | 31 | 10.35 | 2051 | 6 | 6 |
4 | 975.72 | 25 | 12.72 | 1783 | 6 | 9 |
5 | 232.32 | 25 | 13.80 | 706 | 6 | 8 |
6 | 23.48 | 25 | 13.98 | 449 | 6 | 10 |
7 | 0.00 | 180 | 13.90 | 405 | 7 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.36 | 34 | 13.97 | 571 | 6 | 6 |
2 | 928.12 | -2 | 13.97 | 571 | 6 | 6 |
3 | 1140.88 | 10 | 11.41 | 2004 | 6 | 6 |
4 | 1920.12 | 91 | 9.36 | 3129 | 6 | 6 |
5 | 1909.88 | 31 | 10.17 | 3094 | 6 | 6 |
6 | 696.00 | 25 | 13.39 | 1351 | 6 | 10 |
7 | 330.64 | 25 | 13.77 | 857 | 6 | 10 |
8 | 0.76 | 181 | 13.89 | 410 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.48 | 33 | 13.78 | 571 | 6 | 6 |
2 | 980.68 | -1 | 13.78 | 571 | 6 | 6 |
3 | 1176.40 | 91 | 5.91 | 1930 | 6 | 6 |
4 | 1183.80 | 31 | 9.79 | 2035 | 6 | 6 |
5 | 1060.64 | 25 | 12.35 | 1930 | 6 | 8 |
6 | 911.56 | 25 | 12.89 | 1663 | 6 | 9 |
7 | 185.72 | 25 | 13.86 | 654 | 6 | 8 |
8 | 32.08 | 25 | 13.94 | 464 | 6 | 8 |
9 | 0.20 | 181 | 13.88 | 408 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.80 | 33 | 13.91 | 589 | 6 | 7 |
2 | 980.52 | -1 | 13.91 | 589 | 6 | 7 |
3 | 1158.48 | 91 | 6.48 | 1959 | 6 | 6 |
4 | 1167.20 | 31 | 9.89 | 2050 | 6 | 6 |
5 | 1052.52 | 25 | 12.50 | 1915 | 6 | 8 |
6 | 889.36 | 25 | 13.04 | 1608 | 6 | 9 |
7 | 143.36 | 25 | 13.89 | 608 | 6 | 9 |
8 | 0.00 | 181 | 13.89 | 411 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.88 | 33 | 13.91 | 571 | 6 | 6 |
2 | 1158.64 | 91 | 7.68 | 1934 | 6 | 6 |
3 | 1164.00 | 31 | 10.31 | 1998 | 6 | 7 |
4 | 987.04 | 25 | 12.80 | 1749 | 6 | 9 |
5 | 435.88 | 25 | 13.59 | 989 | 6 | 9 |
6 | 41.80 | 25 | 14.01 | 474 | 6 | 9 |
7 | 0.16 | 181 | 13.87 | 412 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 33 | 13.91 | 571 | 6 | 6 |
2 | 1176.40 | 10 | 11.33 | 2062 | 6 | 6 |
3 | 1953.52 | 91 | 9.33 | 3153 | 6 | 6 |
4 | 1943.20 | 31 | 10.17 | 3133 | 6 | 6 |
5 | 1082.48 | 25 | 13.04 | 1904 | 6 | 10 |
6 | 278.00 | 25 | 13.78 | 774 | 6 | 9 |
7 | 19.16 | 25 | 14.02 | 437 | 6 | 9 |
8 | 0.08 | 181 | 13.89 | 410 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.20 | 33 | 13.85 | 571 | 6 | 6 |
2 | 1161.52 | 91 | 5.99 | 1897 | 6 | 6 |
3 | 1169.24 | 31 | 9.89 | 2003 | 6 | 6 |
4 | 1059.12 | 25 | 12.52 | 1867 | 6 | 8 |
5 | 884.16 | 25 | 13.03 | 1599 | 6 | 9 |
6 | 322.80 | 25 | 13.71 | 858 | 6 | 9 |
7 | 0.20 | 180 | 13.89 | 407 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 33 | 13.91 | 571 | 6 | 6 |
2 | 976.76 | -1 | 13.91 | 571 | 6 | 6 |
3 | 1159.72 | 86 | 6.32 | 1927 | 6 | 6 |
4 | 1170.48 | 31 | 9.99 | 2022 | 6 | 6 |
5 | 1077.16 | 25 | 12.51 | 1961 | 6 | 8 |
6 | 908.20 | 25 | 13.06 | 1656 | 6 | 9 |
7 | 173.44 | 25 | 13.89 | 633 | 6 | 8 |
8 | 30.00 | 25 | 13.96 | 449 | 6 | 8 |
9 | 0.00 | 181 | 13.87 | 410 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 33 | 13.91 | 571 | 6 | 6 |
2 | 1149.04 | 86 | 7.69 | 1918 | 6 | 6 |
3 | 1153.88 | 31 | 10.33 | 2034 | 6 | 6 |
4 | 993.68 | 25 | 12.74 | 1826 | 6 | 8 |
5 | 441.40 | 25 | 13.62 | 1008 | 6 | 8 |
6 | 18.56 | 25 | 13.98 | 446 | 6 | 9 |
7 | 0.64 | 181 | 13.84 | 416 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.80 | 34 | 13.91 | 589 | 6 | 6 |
2 | 957.28 | -1 | 13.91 | 589 | 6 | 6 |
3 | 1137.76 | 10 | 11.30 | 1999 | 6 | 6 |
4 | 1935.32 | 87 | 9.44 | 3136 | 6 | 6 |
5 | 1925.76 | 31 | 10.25 | 3081 | 6 | 7 |
6 | 731.16 | 25 | 13.39 | 1408 | 6 | 10 |
7 | 193.72 | 25 | 13.87 | 663 | 6 | 9 |
8 | 0.08 | 181 | 13.96 | 394 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.96 | 34 | 13.85 | 589 | 6 | 6 |
2 | 966.88 | -1 | 13.85 | 589 | 6 | 6 |
3 | 1168.48 | 86 | 5.71 | 1914 | 6 | 6 |
4 | 1177.92 | 31 | 9.83 | 2016 | 6 | 6 |
5 | 1094.68 | 25 | 12.54 | 1929 | 6 | 8 |
6 | 945.48 | 25 | 13.02 | 1712 | 6 | 9 |
7 | 412.24 | 25 | 13.59 | 956 | 6 | 8 |
8 | 38.32 | 25 | 14.01 | 465 | 6 | 8 |
9 | 0.04 | 181 | 13.91 | 402 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 34 | 13.91 | 553 | 6 | 6 |
2 | 971.28 | -1 | 13.91 | 553 | 6 | 6 |
3 | 1134.52 | 86 | 6.34 | 1916 | 6 | 6 |
4 | 1143.00 | 31 | 10.10 | 1979 | 6 | 6 |
5 | 1042.16 | 25 | 12.65 | 1885 | 6 | 8 |
6 | 880.52 | 25 | 13.09 | 1628 | 6 | 10 |
7 | 301.08 | 25 | 13.73 | 803 | 6 | 9 |
8 | 0.36 | 181 | 13.94 | 404 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 34 | 13.85 | 589 | 6 | 6 |
2 | 1139.08 | 86 | 7.50 | 1939 | 6 | 6 |
3 | 1145.20 | 31 | 10.43 | 1987 | 6 | 7 |
4 | 990.56 | 25 | 12.88 | 1826 | 6 | 9 |
5 | 449.88 | 25 | 13.58 | 1010 | 6 | 8 |
6 | 48.00 | 25 | 13.97 | 473 | 6 | 8 |
7 | 0.88 | 181 | 13.95 | 395 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 34 | 13.91 | 571 | 6 | 6 |
2 | 1155.48 | 10 | 11.22 | 2013 | 6 | 6 |
3 | 1921.32 | 87 | 9.65 | 3096 | 6 | 6 |
4 | 1912.04 | 31 | 10.30 | 3105 | 6 | 6 |
5 | 710.08 | 25 | 13.43 | 1371 | 6 | 9 |
6 | 155.28 | 25 | 13.89 | 610 | 6 | 9 |
7 | 0.00 | 181 | 14.01 | 387 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.92 | 34 | 13.97 | 571 | 6 | 6 |
2 | 1177.40 | 86 | 5.57 | 1946 | 6 | 6 |
3 | 1187.04 | 31 | 9.77 | 2051 | 6 | 6 |
4 | 1118.52 | 25 | 12.60 | 1949 | 6 | 8 |
5 | 980.80 | 25 | 12.99 | 1746 | 6 | 9 |
6 | 452.32 | 25 | 13.62 | 1020 | 6 | 9 |
7 | 48.08 | 25 | 14.00 | 474 | 6 | 9 |
8 | 0.00 | 180 | 13.99 | 402 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.24 | 33 | 13.85 | 571 | 6 | 6 |
2 | 1174.36 | 86 | 6.00 | 1892 | 6 | 6 |
3 | 1182.88 | 31 | 9.93 | 2033 | 6 | 6 |
4 | 1090.92 | 25 | 12.63 | 1931 | 6 | 7 |
5 | 925.36 | 25 | 13.06 | 1663 | 6 | 10 |
6 | 355.12 | 25 | 13.70 | 895 | 6 | 9 |
7 | 28.20 | 25 | 13.99 | 446 | 6 | 10 |
8 | 0.12 | 181 | 13.98 | 394 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.04 | 34 | 13.91 | 571 | 6 | 6 |
2 | 1155.00 | 86 | 6.34 | 1927 | 6 | 6 |
3 | 1165.68 | 30 | 10.09 | 2003 | 6 | 6 |
4 | 1072.44 | 25 | 12.68 | 1933 | 6 | 8 |
5 | 915.68 | 25 | 13.09 | 1662 | 6 | 9 |
6 | 177.64 | 25 | 13.85 | 633 | 6 | 8 |
7 | 13.48 | 25 | 14.04 | 424 | 6 | 8 |
8 | 0.04 | 181 | 13.95 | 403 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.80 | 34 | 13.97 | 553 | 6 | 6 |
2 | 968.24 | -1 | 13.97 | 553 | 6 | 6 |
3 | 1178.32 | 86 | 7.58 | 1967 | 6 | 6 |
4 | 1185.32 | 31 | 10.43 | 2059 | 6 | 6 |
5 | 1039.60 | 38 | 12.70 | 1841 | 6 | 8 |
6 | 286.64 | 37 | 13.73 | 777 | 6 | 8 |
7 | 1.68 | 180 | 13.97 | 400 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.20 | 35 | 13.91 | 571 | 6 | 6 |
2 | 974.48 | -1 | 13.91 | 571 | 6 | 6 |
3 | 1160.00 | 10 | 11.36 | 2053 | 6 | 6 |
4 | 1905.88 | 87 | 9.72 | 3074 | 6 | 6 |
5 | 1896.52 | 31 | 10.33 | 3031 | 6 | 7 |
6 | 681.84 | 37 | 13.33 | 1319 | 6 | 8 |
7 | 23.52 | 37 | 13.99 | 437 | 6 | 9 |
8 | -0.08 | 181 | 13.98 | 403 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 33 | 13.91 | 571 | 6 | 6 |
2 | 1172.32 | 86 | 5.99 | 1990 | 6 | 6 |
3 | 1181.88 | 31 | 9.98 | 2045 | 6 | 6 |
4 | 1092.28 | 38 | 12.46 | 1906 | 6 | 7 |
5 | 745.80 | 38 | 13.19 | 1399 | 6 | 9 |
6 | 56.16 | 37 | 13.93 | 485 | 6 | 9 |
7 | -0.12 | 181 | 13.93 | 405 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.16 | 34 | 13.85 | 571 | 6 | 6 |
2 | 974.60 | -1 | 13.85 | 571 | 6 | 6 |
3 | 1175.68 | 86 | 5.84 | 1972 | 6 | 6 |
4 | 1185.52 | 31 | 9.91 | 2047 | 6 | 6 |
5 | 1110.12 | 38 | 12.43 | 1963 | 6 | 8 |
6 | 938.24 | 38 | 12.91 | 1697 | 6 | 8 |
7 | 25.32 | 37 | 13.96 | 437 | 6 | 9 |
8 | 0.16 | 181 | 13.97 | 397 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.40 | 34 | 13.97 | 571 | 6 | 6 |
2 | 1137.48 | 86 | 6.55 | 1893 | 6 | 6 |
3 | 1147.00 | 31 | 10.16 | 1969 | 6 | 6 |
4 | 1030.28 | 38 | 12.62 | 1813 | 6 | 9 |
5 | 502.88 | 38 | 13.46 | 1073 | 6 | 10 |
6 | 0.24 | 181 | 13.92 | 404 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 35 | 13.85 | 571 | 6 | 6 |
2 | 944.80 | -2 | 13.85 | 571 | 6 | 6 |
3 | 1174.72 | 86 | 7.37 | 2008 | 6 | 6 |
4 | 1182.28 | 31 | 10.33 | 2086 | 6 | 6 |
5 | 1046.96 | 38 | 12.60 | 1891 | 6 | 8 |
6 | 287.04 | 37 | 13.72 | 789 | 6 | 9 |
7 | 0.04 | 181 | 13.96 | 401 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.08 | 35 | 13.91 | 571 | 6 | 6 |
2 | 970.72 | -1 | 13.91 | 571 | 6 | 6 |
3 | 1154.04 | 10 | 11.28 | 2044 | 6 | 6 |
4 | 1924.08 | 87 | 9.71 | 3107 | 6 | 6 |
5 | 1914.28 | 31 | 10.29 | 3106 | 6 | 7 |
6 | 715.84 | 37 | 13.30 | 1359 | 6 | 10 |
7 | 4.92 | 37 | 14.08 | 400 | 6 | 16 |
8 | 0.04 | 180 | 14.00 | 406 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.16 | 34 | 13.85 | 571 | 6 | 6 |
2 | 1170.80 | 86 | 6.15 | 1898 | 6 | 6 |
3 | 1180.28 | 31 | 9.86 | 2054 | 6 | 6 |
4 | 1067.32 | 38 | 12.51 | 1890 | 6 | 8 |
5 | 712.72 | 38 | 13.22 | 1337 | 6 | 9 |
6 | -0.04 | 181 | 13.99 | 385 | 6 | 38 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.68 | 34 | 13.97 | 571 | 6 | 6 |
2 | 1144.76 | 86 | 6.42 | 1888 | 6 | 6 |
3 | 1153.36 | 31 | 10.04 | 2020 | 6 | 6 |
4 | 1040.64 | 38 | 12.52 | 1884 | 6 | 9 |
5 | 500.44 | 38 | 13.47 | 1061 | 6 | 9 |
6 | 0.04 | 181 | 13.95 | 392 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.32 | 36 | 13.97 | 571 | 6 | 6 |
2 | 952.56 | -1 | 13.97 | 571 | 6 | 6 |
3 | 1146.20 | 86 | 6.56 | 1927 | 6 | 6 |
4 | 1156.24 | 31 | 10.04 | 2064 | 6 | 6 |
5 | 1040.40 | 38 | 12.61 | 1867 | 6 | 9 |
6 | 508.04 | 38 | 13.48 | 1071 | 6 | 10 |
7 | 0.20 | 181 | 13.95 | 401 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.36 | 38 | 13.78 | 589 | 6 | 7 |
2 | 877.48 | -3 | 13.78 | 589 | 6 | 7 |
3 | 1122.64 | 86 | 7.60 | 1882 | 6 | 6 |
4 | 1128.80 | 31 | 10.49 | 2003 | 6 | 7 |
5 | 967.60 | 38 | 12.80 | 1763 | 6 | 9 |
6 | 182.00 | 37 | 13.82 | 666 | 6 | 10 |
7 | 0.00 | 181 | 13.92 | 416 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 35 | 13.85 | 589 | 6 | 6 |
2 | 1144.48 | 12 | 11.36 | 2063 | 6 | 6 |
3 | 1844.52 | 87 | 10.05 | 2980 | 6 | 6 |
4 | 1834.52 | 31 | 10.39 | 2975 | 6 | 7 |
5 | 764.48 | 38 | 13.22 | 1460 | 6 | 9 |
6 | 17.92 | 38 | 14.01 | 444 | 6 | 9 |
7 | 0.64 | 181 | 13.94 | 411 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.20 | 35 | 13.85 | 589 | 6 | 6 |
2 | 951.64 | -1 | 13.85 | 589 | 6 | 6 |
3 | 1145.76 | 86 | 6.42 | 1961 | 6 | 6 |
4 | 1154.12 | 31 | 10.10 | 2007 | 6 | 6 |
5 | 1041.00 | 38 | 12.61 | 1887 | 6 | 9 |
6 | 504.56 | 38 | 13.45 | 1098 | 6 | 9 |
7 | 0.24 | 180 | 13.92 | 403 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.84 | 34 | 13.85 | 571 | 6 | 6 |
2 | 1185.28 | 86 | 6.22 | 1995 | 6 | 6 |
3 | 1195.40 | 31 | 10.07 | 2049 | 6 | 6 |
4 | 1105.64 | 38 | 12.60 | 1921 | 6 | 9 |
5 | 740.40 | 38 | 13.22 | 1393 | 6 | 9 |
6 | 18.44 | 37 | 14.00 | 436 | 6 | 8 |
7 | 0.28 | 181 | 13.96 | 400 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 34 | 13.78 | 589 | 6 | 6 |
2 | 1005.08 | 3 | 12.95 | 1857 | 6 | 6 |
3 | 1184.20 | 86 | 6.56 | 2022 | 6 | 6 |
4 | 1192.84 | 31 | 10.26 | 2040 | 6 | 6 |
5 | 1080.92 | 38 | 12.69 | 1896 | 6 | 9 |
6 | 532.92 | 38 | 13.45 | 1118 | 6 | 9 |
7 | 0.04 | 181 | 13.91 | 412 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.60 | 34 | 13.85 | 553 | 6 | 6 |
2 | 1162.60 | 86 | 7.64 | 1945 | 6 | 6 |
3 | 1168.32 | 31 | 10.39 | 2063 | 6 | 6 |
4 | 1002.36 | 38 | 12.89 | 1794 | 6 | 9 |
5 | 205.96 | 37 | 13.82 | 668 | 6 | 9 |
6 | -0.12 | 181 | 13.94 | 395 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.56 | 34 | 13.85 | 535 | 6 | 6 |
2 | 1051.52 | 1 | 11.37 | 1910 | 6 | 6 |
3 | 1187.16 | 12 | 12.60 | 2085 | 6 | 6 |
4 | 1900.60 | 87 | 10.16 | 3076 | 6 | 6 |
5 | 1889.92 | 31 | 10.41 | 3036 | 6 | 7 |
6 | 651.12 | 37 | 13.37 | 1272 | 6 | 9 |
7 | 0.20 | 180 | 13.97 | 386 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.72 | 34 | 13.85 | 553 | 6 | 6 |
2 | 1165.48 | 86 | 6.22 | 1949 | 6 | 6 |
3 | 1174.36 | 31 | 9.85 | 2044 | 6 | 6 |
4 | 1074.00 | 38 | 12.56 | 1913 | 6 | 8 |
5 | 557.88 | 38 | 13.39 | 1145 | 6 | 9 |
6 | 0.12 | 181 | 13.94 | 392 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.52 | 34 | 13.85 | 571 | 6 | 6 |
2 | 1163.12 | 86 | 6.27 | 1946 | 6 | 6 |
3 | 1172.40 | 30 | 10.06 | 2024 | 6 | 6 |
4 | 1065.00 | 37 | 12.61 | 1919 | 6 | 8 |
5 | 533.52 | 37 | 13.47 | 1108 | 6 | 8 |
6 | 0.00 | 181 | 13.95 | 390 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.56 | 34 | 13.85 | 571 | 6 | 6 |
2 | 1147.00 | 86 | 6.92 | 1888 | 6 | 6 |
3 | 1153.52 | 31 | 10.25 | 1989 | 6 | 6 |
4 | 1006.08 | 38 | 12.77 | 1806 | 6 | 8 |
5 | 256.68 | 37 | 13.74 | 733 | 6 | 8 |
6 | 0.28 | 181 | 13.95 | 395 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 33 | 13.85 | 589 | 6 | 6 |
2 | 1052.84 | 1 | 12.00 | 1946 | 6 | 6 |
3 | 1179.36 | 86 | 7.53 | 1983 | 6 | 6 |
4 | 1185.60 | 31 | 10.50 | 2030 | 6 | 6 |
5 | 1028.36 | 38 | 12.85 | 1838 | 6 | 8 |
6 | 248.64 | 37 | 13.74 | 739 | 6 | 9 |
7 | 0.24 | 180 | 13.96 | 394 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.76 | 34 | 13.85 | 571 | 6 | 6 |
2 | 1158.16 | 12 | 11.50 | 2081 | 6 | 6 |
3 | 1862.56 | 87 | 10.21 | 3018 | 6 | 6 |
4 | 1852.72 | 31 | 10.46 | 3024 | 6 | 7 |
5 | 619.64 | 37 | 13.37 | 1246 | 6 | 9 |
6 | 0.12 | 181 | 13.93 | 407 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.16 | 34 | 13.85 | 589 | 6 | 6 |
2 | 1169.56 | 86 | 6.27 | 1933 | 6 | 6 |
3 | 1178.80 | 31 | 9.99 | 2023 | 6 | 6 |
4 | 1073.16 | 38 | 12.66 | 1896 | 6 | 9 |
5 | 527.32 | 38 | 13.46 | 1093 | 6 | 9 |
6 | 0.00 | 181 | 13.95 | 393 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.88 | 34 | 13.85 | 553 | 6 | 6 |
2 | 1177.08 | 86 | 6.40 | 1955 | 6 | 6 |
3 | 1185.80 | 31 | 10.02 | 2062 | 6 | 6 |
4 | 1057.16 | 38 | 12.73 | 1891 | 6 | 9 |
5 | 683.72 | 38 | 13.31 | 1316 | 6 | 9 |
6 | 0.16 | 181 | 13.97 | 392 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.48 | 33 | 13.85 | 589 | 6 | 6 |
2 | 1154.12 | 86 | 7.04 | 1954 | 6 | 6 |
3 | 1163.08 | 31 | 10.20 | 2053 | 6 | 6 |
4 | 1027.44 | 38 | 12.77 | 1848 | 6 | 8 |
5 | 450.00 | 38 | 13.56 | 993 | 6 | 10 |
6 | 0.32 | 181 | 13.94 | 405 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.72 | 34 | 13.85 | 571 | 6 | 6 |
2 | 981.08 | -1 | 13.85 | 571 | 6 | 6 |
3 | 1196.52 | 86 | 7.55 | 2007 | 6 | 6 |
4 | 1202.64 | 30 | 10.44 | 2118 | 6 | 6 |
5 | 1040.52 | 37 | 12.90 | 1841 | 6 | 9 |
6 | 255.36 | 37 | 13.79 | 722 | 6 | 8 |
7 | 0.08 | 181 | 13.97 | 398 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 36 | 13.91 | 571 | 6 | 7 |
2 | 916.36 | -2 | 13.91 | 571 | 6 | 7 |
3 | 1143.28 | 12 | 11.77 | 2046 | 6 | 6 |
4 | 1848.08 | 85 | 10.37 | 3009 | 6 | 6 |
5 | 1838.04 | 30 | 10.51 | 2980 | 6 | 7 |
6 | 576.84 | 37 | 13.41 | 1193 | 6 | 9 |
7 | 0.08 | 181 | 13.92 | 413 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.36 | 34 | 13.85 | 589 | 6 | 6 |
2 | 955.48 | -1 | 13.85 | 589 | 6 | 6 |
3 | 1130.08 | 86 | 6.56 | 1878 | 6 | 6 |
4 | 1137.40 | 31 | 10.06 | 1978 | 6 | 6 |
5 | 1012.64 | 38 | 12.78 | 1803 | 6 | 8 |
6 | 641.00 | 38 | 13.31 | 1261 | 6 | 10 |
7 | 0.12 | 181 | 13.98 | 390 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.96 | 35 | 13.91 | 607 | 6 | 6 |
2 | 962.56 | -1 | 13.91 | 607 | 6 | 6 |
3 | 1138.20 | 86 | 6.87 | 1941 | 6 | 6 |
4 | 1146.44 | 31 | 10.29 | 1995 | 6 | 6 |
5 | 1013.16 | 38 | 12.84 | 1804 | 6 | 9 |
6 | 451.36 | 38 | 13.52 | 1004 | 6 | 9 |
7 | 0.04 | 181 | 13.97 | 395 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 35 | 13.91 | 571 | 6 | 6 |
2 | 946.68 | -1 | 13.91 | 571 | 6 | 6 |
3 | 1147.00 | 86 | 7.22 | 1924 | 6 | 6 |
4 | 1153.52 | 31 | 10.34 | 2037 | 6 | 6 |
5 | 1006.00 | 38 | 12.85 | 1806 | 6 | 9 |
6 | 256.76 | 37 | 13.76 | 729 | 6 | 9 |
7 | 0.24 | 181 | 13.91 | 413 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.84 | 37 | 13.91 | 553 | 6 | 6 |
2 | 888.60 | -3 | 13.91 | 553 | 6 | 6 |
3 | 1112.80 | 86 | 7.95 | 1903 | 6 | 6 |
4 | 1118.64 | 30 | 10.67 | 2001 | 6 | 7 |
5 | 952.76 | 37 | 13.01 | 1718 | 6 | 9 |
6 | 145.20 | 37 | 13.85 | 597 | 6 | 8 |
7 | 0.04 | 181 | 13.95 | 403 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.84 | 36 | 13.78 | 607 | 6 | 6 |
2 | 948.32 | -1 | 13.78 | 607 | 6 | 6 |
3 | 1123.24 | 10 | 11.78 | 2035 | 6 | 6 |
4 | 1902.76 | 85 | 10.33 | 3101 | 6 | 6 |
5 | 1892.04 | 31 | 10.50 | 3086 | 6 | 8 |
6 | 626.88 | 37 | 13.40 | 1230 | 6 | 9 |
7 | 15.32 | 37 | 14.07 | 423 | 6 | 7 |
8 | 2.52 | 37 | 14.06 | 412 | 6 | 26 |
9 | 0.04 | 180 | 13.95 | 395 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.36 | 36 | 13.91 | 571 | 6 | 6 |
2 | 956.44 | -1 | 13.91 | 571 | 6 | 6 |
3 | 1164.68 | 86 | 6.72 | 1911 | 6 | 6 |
4 | 1174.64 | 31 | 10.10 | 2057 | 6 | 6 |
5 | 1058.12 | 38 | 12.74 | 1875 | 6 | 9 |
6 | 489.80 | 38 | 13.53 | 1026 | 6 | 9 |
7 | 0.24 | 181 | 13.91 | 413 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.12 | 37 | 13.91 | 589 | 6 | 6 |
2 | 924.88 | -2 | 13.91 | 589 | 6 | 6 |
3 | 1112.64 | 86 | 6.90 | 1860 | 6 | 6 |
4 | 1119.76 | 31 | 10.20 | 1966 | 6 | 6 |
5 | 989.28 | 38 | 12.86 | 1782 | 6 | 9 |
6 | 240.16 | 37 | 13.71 | 730 | 6 | 9 |
7 | 0.08 | 181 | 13.88 | 419 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.96 | 36 | 13.85 | 571 | 6 | 6 |
2 | 1187.56 | 86 | 7.01 | 1963 | 6 | 6 |
3 | 1196.36 | 31 | 10.33 | 2078 | 6 | 6 |
4 | 1057.72 | 38 | 12.86 | 1881 | 6 | 9 |
5 | 310.20 | 37 | 13.69 | 821 | 6 | 9 |
6 | 0.24 | 180 | 13.94 | 416 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.80 | 37 | 13.85 | 553 | 6 | 6 |
2 | 960.44 | -1 | 13.85 | 553 | 6 | 6 |
3 | 1142.16 | 70 | 7.64 | 1969 | 6 | 6 |
4 | 1148.68 | 41 | 10.40 | 2038 | 6 | 6 |
5 | 979.04 | 38 | 12.94 | 1793 | 6 | 10 |
6 | 356.64 | 38 | 13.67 | 879 | 6 | 10 |
7 | 0.12 | 181 | 13.92 | 420 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.08 | 36 | 13.91 | 571 | 6 | 6 |
2 | 1175.68 | 10 | 12.83 | 2071 | 6 | 6 |
3 | 1700.76 | 70 | 10.74 | 2789 | 6 | 6 |
4 | 1695.28 | 40 | 10.66 | 2784 | 6 | 8 |
5 | 856.20 | 37 | 13.19 | 1560 | 6 | 9 |
6 | 220.72 | 37 | 13.85 | 686 | 6 | 9 |
7 | 0.12 | 181 | 13.98 | 402 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.32 | 38 | 13.91 | 553 | 6 | 6 |
2 | 974.68 | -1 | 13.91 | 553 | 6 | 6 |
3 | 1136.96 | 70 | 6.27 | 1899 | 6 | 6 |
4 | 1145.64 | 40 | 9.65 | 1980 | 6 | 6 |
5 | 1053.68 | 37 | 12.77 | 1879 | 6 | 8 |
6 | 683.56 | 37 | 13.31 | 1312 | 6 | 9 |
7 | 0.28 | 180 | 13.95 | 406 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 38 | 13.91 | 589 | 6 | 6 |
2 | 1135.80 | 70 | 6.70 | 1904 | 6 | 6 |
3 | 1144.12 | 41 | 9.84 | 1976 | 6 | 6 |
4 | 1034.16 | 38 | 12.84 | 1836 | 6 | 8 |
5 | 476.56 | 38 | 13.54 | 1025 | 6 | 10 |
6 | 0.60 | 181 | 13.98 | 390 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 38 | 13.85 | 571 | 6 | 6 |
2 | 943.64 | -2 | 13.85 | 571 | 6 | 6 |
3 | 1203.16 | 70 | 6.60 | 2031 | 6 | 6 |
4 | 1211.64 | 41 | 10.07 | 2099 | 6 | 6 |
5 | 1099.40 | 38 | 12.82 | 1930 | 6 | 9 |
6 | 551.64 | 38 | 13.50 | 1147 | 6 | 9 |
7 | 0.64 | 181 | 13.99 | 402 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.76 | 36 | 13.85 | 589 | 6 | 6 |
2 | 1003.36 | 3 | 13.08 | 1875 | 6 | 6 |
3 | 973.80 | -1 | 13.08 | 1875 | 6 | 6 |
4 | 1116.12 | 70 | 8.03 | 1883 | 6 | 6 |
5 | 1122.60 | 41 | 10.66 | 1949 | 6 | 6 |
6 | 968.36 | 38 | 12.99 | 1760 | 6 | 9 |
7 | 145.48 | 38 | 13.91 | 603 | 6 | 9 |
8 | -0.12 | 181 | 13.93 | 421 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.08 | 38 | 13.91 | 571 | 6 | 6 |
2 | 939.64 | -2 | 13.91 | 571 | 6 | 6 |
3 | 1169.20 | 10 | 11.77 | 2075 | 6 | 6 |
4 | 1659.32 | 61 | 10.94 | 2748 | 6 | 6 |
5 | 1654.84 | 41 | 10.71 | 2717 | 6 | 8 |
6 | 866.56 | 38 | 13.22 | 1551 | 6 | 9 |
7 | 0.08 | 181 | 14.01 | 391 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 36 | 13.91 | 589 | 6 | 6 |
2 | 1008.24 | 3 | 12.89 | 1892 | 6 | 7 |
3 | 976.92 | -1 | 12.89 | 1892 | 6 | 7 |
4 | 1160.64 | 61 | 6.03 | 1926 | 6 | 6 |
5 | 1167.76 | 41 | 9.70 | 1999 | 6 | 6 |
6 | 1099.36 | 38 | 12.78 | 1964 | 6 | 9 |
7 | 739.04 | 38 | 13.29 | 1409 | 6 | 10 |
8 | 0.16 | 181 | 13.96 | 404 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 35 | 13.91 | 571 | 6 | 6 |
2 | 1042.20 | 1 | 12.63 | 1875 | 6 | 6 |
3 | 1213.40 | 51 | 6.05 | 2102 | 6 | 6 |
4 | 1220.84 | 41 | 9.94 | 2071 | 6 | 6 |
5 | 1180.56 | 38 | 12.71 | 2068 | 6 | 8 |
6 | 841.36 | 38 | 13.16 | 1567 | 6 | 10 |
7 | 32.36 | 181 | 13.91 | 432 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 38 | 13.91 | 571 | 6 | 6 |
2 | 943.72 | -2 | 13.91 | 571 | 6 | 6 |
3 | 1154.76 | 51 | 6.69 | 1919 | 6 | 6 |
4 | 1162.00 | 41 | 10.19 | 2015 | 6 | 6 |
5 | 1080.36 | 38 | 12.85 | 1947 | 6 | 8 |
6 | 719.24 | 38 | 13.32 | 1371 | 6 | 9 |
7 | 0.12 | 181 | 13.99 | 402 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.24 | 36 | 13.91 | 571 | 6 | 6 |
2 | 1010.92 | 4 | 13.14 | 1910 | 6 | 7 |
3 | 967.12 | -1 | 13.14 | 1910 | 6 | 7 |
4 | 1151.00 | 50 | 8.07 | 1941 | 6 | 6 |
5 | 1157.96 | 41 | 10.87 | 2001 | 6 | 6 |
6 | 1021.76 | 38 | 12.96 | 1833 | 6 | 10 |
7 | 289.84 | 37 | 13.75 | 780 | 6 | 8 |
8 | -0.04 | 181 | 13.97 | 408 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.04 | 39 | 13.97 | 553 | 6 | 6 |
2 | 956.52 | -1 | 13.97 | 553 | 6 | 6 |
3 | 1150.88 | 11 | 12.08 | 2031 | 6 | 6 |
4 | 1648.24 | 50 | 11.30 | 2732 | 6 | 6 |
5 | 1644.92 | 41 | 10.85 | 2723 | 6 | 8 |
6 | 1060.16 | 38 | 13.00 | 1868 | 6 | 9 |
7 | 39.20 | 37 | 14.06 | 447 | 6 | 7 |
8 | 0.16 | 181 | 14.01 | 400 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.44 | 39 | 13.85 | 571 | 6 | 7 |
2 | 872.24 | -4 | 13.85 | 571 | 6 | 7 |
3 | 1205.88 | 50 | 5.72 | 2076 | 6 | 6 |
4 | 1213.36 | 41 | 9.76 | 2070 | 6 | 6 |
5 | 1169.40 | 38 | 12.72 | 2071 | 6 | 7 |
6 | 999.28 | 38 | 13.06 | 1782 | 6 | 10 |
7 | 79.64 | 37 | 13.98 | 503 | 6 | 8 |
8 | 14.96 | 181 | 13.97 | 414 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.36 | 38 | 13.85 | 553 | 6 | 6 |
2 | 1022.36 | 1 | 12.31 | 1839 | 6 | 6 |
3 | 1152.08 | 51 | 6.56 | 1888 | 6 | 6 |
4 | 1158.24 | 41 | 10.04 | 1981 | 6 | 6 |
5 | 1066.36 | 38 | 12.90 | 1847 | 6 | 9 |
6 | 693.00 | 38 | 13.36 | 1324 | 6 | 9 |
7 | 0.12 | 181 | 13.93 | 406 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.68 | 37 | 13.91 | 589 | 6 | 6 |
2 | 949.40 | -1 | 13.91 | 589 | 6 | 6 |
3 | 1119.64 | 51 | 7.09 | 1847 | 6 | 6 |
4 | 1127.28 | 41 | 10.48 | 1967 | 6 | 6 |
5 | 1022.32 | 38 | 12.95 | 1824 | 6 | 9 |
6 | 472.04 | 38 | 13.57 | 1019 | 6 | 9 |
7 | 0.20 | 181 | 13.94 | 405 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.40 | 38 | 13.97 | 535 | 6 | 6 |
2 | 950.32 | -1 | 13.97 | 535 | 6 | 6 |
3 | 1156.00 | 50 | 8.15 | 1941 | 6 | 6 |
4 | 1162.64 | 41 | 10.87 | 2036 | 6 | 6 |
5 | 1002.80 | 38 | 12.99 | 1822 | 6 | 8 |
6 | 248.28 | 37 | 13.81 | 727 | 6 | 8 |
7 | 0.28 | 181 | 13.96 | 412 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.68 | 40 | 13.85 | 571 | 6 | 6 |
2 | 963.68 | -1 | 13.85 | 571 | 6 | 6 |
3 | 1161.80 | 11 | 12.07 | 2085 | 6 | 6 |
4 | 1919.48 | 50 | 10.98 | 3138 | 6 | 7 |
5 | 1914.20 | 41 | 10.58 | 3121 | 7 | 8 |
6 | 1109.04 | 38 | 12.94 | 1950 | 6 | 10 |
7 | 297.36 | 37 | 13.74 | 788 | 6 | 9 |
8 | -0.04 | 181 | 14.00 | 397 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.08 | 38 | 13.91 | 571 | 6 | 6 |
2 | 1113.92 | 51 | 6.60 | 1834 | 6 | 6 |
3 | 1121.32 | 41 | 10.02 | 1938 | 6 | 6 |
4 | 1027.20 | 38 | 12.85 | 1870 | 6 | 8 |
5 | 651.16 | 38 | 13.36 | 1284 | 6 | 9 |
6 | 0.04 | 181 | 13.93 | 419 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.60 | 39 | 13.78 | 589 | 6 | 6 |
2 | 951.08 | -1 | 13.78 | 589 | 6 | 6 |
3 | 1177.88 | 50 | 6.51 | 1962 | 6 | 6 |
4 | 1187.28 | 41 | 10.27 | 2037 | 6 | 6 |
5 | 1134.32 | 38 | 12.82 | 1998 | 6 | 9 |
6 | 788.80 | 38 | 13.25 | 1494 | 6 | 10 |
7 | 8.16 | 37 | 14.12 | 414 | 6 | 8 |
8 | 0.16 | 181 | 13.94 | 413 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.88 | 39 | 13.85 | 589 | 6 | 6 |
2 | 953.32 | -1 | 13.85 | 589 | 6 | 6 |
3 | 1129.84 | 51 | 7.32 | 1934 | 6 | 6 |
4 | 1136.84 | 41 | 10.78 | 1987 | 6 | 7 |
5 | 1039.76 | 38 | 12.91 | 1874 | 6 | 8 |
6 | 334.92 | 38 | 13.71 | 859 | 6 | 9 |
7 | 0.32 | 181 | 13.94 | 416 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.24 | 37 | 13.97 | 553 | 6 | 6 |
2 | 1045.48 | 1 | 12.70 | 1875 | 6 | 6 |
3 | 1165.76 | 41 | 8.40 | 1968 | 6 | 6 |
4 | 1171.56 | 41 | 11.15 | 2023 | 6 | 6 |
5 | 1047.36 | 38 | 12.94 | 1860 | 6 | 10 |
6 | 534.12 | 38 | 13.53 | 1108 | 6 | 9 |
7 | -0.28 | 181 | 13.95 | 418 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.44 | 38 | 13.91 | 571 | 6 | 6 |
2 | 1080.76 | 2 | 12.82 | 1910 | 6 | 6 |
3 | 1194.64 | 11 | 12.20 | 2124 | 6 | 6 |
4 | 1910.40 | 41 | 11.24 | 3113 | 6 | 6 |
5 | 1906.88 | 41 | 10.70 | 3127 | 6 | 7 |
6 | 1310.20 | 38 | 12.70 | 2288 | 6 | 10 |
7 | 121.88 | 37 | 13.94 | 578 | 6 | 9 |
8 | 0.20 | 180 | 13.99 | 408 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.20 | 42 | 13.91 | 589 | 6 | 6 |
2 | 876.96 | -3 | 13.91 | 589 | 6 | 6 |
3 | 1107.60 | 41 | 6.20 | 1834 | 6 | 6 |
4 | 1114.36 | 41 | 9.76 | 1909 | 6 | 6 |
5 | 1097.76 | 38 | 12.75 | 1963 | 6 | 8 |
6 | 942.24 | 38 | 13.03 | 1717 | 6 | 9 |
7 | 54.08 | 37 | 14.02 | 484 | 6 | 8 |
8 | -0.32 | 181 | 13.95 | 422 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.32 | 39 | 13.85 | 571 | 6 | 6 |
2 | 1001.36 | 3 | 12.76 | 1821 | 6 | 6 |
3 | 1149.40 | 51 | 6.25 | 1919 | 6 | 6 |
4 | 1155.40 | 41 | 10.12 | 1967 | 6 | 6 |
5 | 1111.80 | 38 | 12.81 | 1973 | 6 | 8 |
6 | 945.44 | 38 | 13.10 | 1707 | 6 | 8 |
7 | 0.56 | 180 | 13.95 | 413 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.80 | 38 | 13.85 | 589 | 6 | 6 |
2 | 959.88 | -1 | 13.85 | 589 | 6 | 6 |
3 | 999.36 | 40 | 6.94 | 1702 | 6 | 6 |
4 | 887.64 | 38 | 12.99 | 1639 | 6 | 8 |
5 | 327.28 | 38 | 13.67 | 842 | 6 | 8 |
6 | -0.04 | 181 | 13.93 | 411 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 39 | 13.91 | 571 | 6 | 6 |
2 | 954.32 | -1 | 13.91 | 571 | 6 | 6 |
3 | 993.76 | 40 | 8.01 | 1732 | 6 | 6 |
4 | 864.36 | 38 | 13.13 | 1587 | 6 | 9 |
5 | 4.72 | 38 | 14.09 | 402 | 6 | 8 |
6 | -0.08 | 180 | 13.91 | 410 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.04 | 38 | 13.91 | 607 | 6 | 6 |
2 | 1139.60 | 14 | 12.16 | 2038 | 6 | 6 |
3 | 1568.44 | 50 | 11.86 | 2658 | 6 | 6 |
4 | 1567.64 | 40 | 10.99 | 2623 | 6 | 7 |
5 | 608.44 | 38 | 13.49 | 1223 | 6 | 9 |
6 | 0.20 | 180 | 14.01 | 400 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.84 | 38 | 13.85 | 589 | 6 | 6 |
2 | 1035.48 | 1 | 12.57 | 1857 | 6 | 6 |
3 | 1176.88 | 50 | 6.45 | 2043 | 6 | 6 |
4 | 1183.00 | 41 | 10.04 | 2015 | 6 | 6 |
5 | 1116.56 | 38 | 12.86 | 1953 | 6 | 8 |
6 | 768.48 | 38 | 13.30 | 1442 | 6 | 9 |
7 | 22.84 | 38 | 14.09 | 431 | 6 | 7 |
8 | -0.12 | 181 | 13.98 | 416 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.20 | 41 | 13.91 | 589 | 6 | 7 |
2 | 891.44 | -3 | 13.91 | 589 | 6 | 7 |
3 | 1130.88 | 51 | 6.28 | 1886 | 6 | 6 |
4 | 1136.92 | 41 | 10.12 | 1963 | 6 | 6 |
5 | 1076.88 | 38 | 12.83 | 1945 | 6 | 9 |
6 | 723.16 | 38 | 13.30 | 1412 | 6 | 11 |
7 | -0.04 | 181 | 13.98 | 413 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.24 | 37 | 13.85 | 589 | 6 | 6 |
2 | 1076.60 | 2 | 12.44 | 1892 | 6 | 6 |
3 | 1022.24 | 40 | 6.97 | 1734 | 6 | 6 |
4 | 908.68 | 38 | 13.06 | 1653 | 6 | 9 |
5 | 341.36 | 38 | 13.70 | 843 | 6 | 9 |
6 | 0.24 | 181 | 13.98 | 413 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.80 | 36 | 13.91 | 571 | 6 | 6 |
2 | 1034.36 | 1 | 12.70 | 1821 | 6 | 6 |
3 | 1022.08 | 40 | 8.43 | 1780 | 6 | 6 |
4 | 896.88 | 38 | 13.08 | 1649 | 6 | 8 |
5 | 151.36 | 38 | 13.89 | 611 | 6 | 8 |
6 | 0.00 | 181 | 13.98 | 416 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.28 | 36 | 13.91 | 571 | 6 | 6 |
2 | 1045.64 | 1 | 12.38 | 1875 | 6 | 6 |
3 | 1178.00 | 14 | 12.32 | 2071 | 6 | 6 |
4 | 1621.56 | 50 | 11.88 | 2712 | 6 | 6 |
5 | 1620.84 | 40 | 10.93 | 2688 | 6 | 7 |
6 | 629.08 | 38 | 13.46 | 1257 | 6 | 9 |
7 | 41.52 | 38 | 14.09 | 456 | 6 | 8 |
8 | -0.04 | 181 | 14.00 | 417 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.16 | 37 | 13.91 | 553 | 6 | 6 |
2 | 1006.12 | 3 | 13.08 | 1892 | 6 | 7 |
3 | 1036.76 | 1 | 12.70 | 1875 | 6 | 6 |
4 | 1168.32 | 50 | 6.37 | 2014 | 6 | 6 |
5 | 1174.84 | 41 | 10.15 | 2008 | 6 | 6 |
6 | 1121.64 | 38 | 12.84 | 1966 | 6 | 8 |
7 | 772.32 | 38 | 13.31 | 1438 | 6 | 11 |
8 | 0.28 | 181 | 14.04 | 396 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.36 | 27 | 13.97 | 571 | 6 | 6 |
2 | 1039.32 | 5 | 13.02 | 1946 | 6 | 6 |
3 | 1066.56 | 3 | 13.21 | 1946 | 6 | 6 |
4 | 1085.36 | 2 | 12.89 | 1946 | 6 | 6 |
5 | 1200.44 | 51 | 6.03 | 1990 | 6 | 6 |
6 | 1207.12 | 41 | 10.29 | 2058 | 6 | 6 |
7 | 1145.16 | 38 | 12.80 | 2000 | 6 | 10 |
8 | 790.12 | 38 | 13.28 | 1455 | 6 | 9 |
9 | 0.04 | 181 | 14.00 | 406 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.48 | 36 | 13.91 | 589 | 6 | 6 |
2 | 998.76 | 40 | 6.60 | 1706 | 6 | 6 |
3 | 891.52 | 38 | 12.99 | 1631 | 6 | 9 |
4 | 350.08 | 38 | 13.62 | 881 | 6 | 9 |
5 | -0.16 | 181 | 14.00 | 393 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.76 | 38 | 13.91 | 571 | 6 | 6 |
2 | 943.68 | -2 | 13.91 | 571 | 6 | 6 |
3 | 1003.80 | 40 | 7.25 | 1730 | 6 | 6 |
4 | 892.08 | 38 | 13.04 | 1630 | 6 | 9 |
5 | 334.76 | 38 | 13.71 | 873 | 6 | 10 |
6 | -0.04 | 181 | 14.00 | 407 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.36 | 39 | 13.91 | 589 | 6 | 6 |
2 | 947.16 | -1 | 13.91 | 589 | 6 | 6 |
3 | 975.92 | 40 | 8.68 | 1715 | 6 | 6 |
4 | 834.56 | 38 | 13.13 | 1557 | 6 | 9 |
5 | 101.60 | 38 | 13.94 | 551 | 6 | 7 |
6 | 0.36 | 180 | 13.97 | 417 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.16 | 37 | 13.91 | 589 | 6 | 6 |
2 | 960.12 | -1 | 13.91 | 589 | 6 | 6 |
3 | 1154.68 | 14 | 12.30 | 2068 | 6 | 6 |
4 | 1580.68 | 50 | 11.89 | 2648 | 6 | 7 |
5 | 1579.60 | 40 | 11.00 | 2644 | 7 | 8 |
6 | 588.04 | 38 | 13.45 | 1216 | 6 | 10 |
7 | -0.12 | 181 | 14.04 | 399 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 35 | 13.91 | 571 | 6 | 6 |
2 | 1003.80 | 4 | 13.02 | 1821 | 6 | 7 |
3 | 1030.16 | 1 | 12.44 | 1821 | 6 | 6 |
4 | 1022.56 | 40 | 7.05 | 1706 | 6 | 6 |
5 | 902.80 | 38 | 13.00 | 1640 | 6 | 10 |
6 | 345.92 | 38 | 13.70 | 861 | 6 | 10 |
7 | 0.00 | 181 | 14.01 | 395 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.60 | 35 | 13.91 | 571 | 6 | 6 |
2 | 1004.20 | 40 | 7.86 | 1722 | 6 | 6 |
3 | 869.52 | 38 | 13.03 | 1615 | 6 | 9 |
4 | 135.32 | 38 | 13.90 | 583 | 6 | 9 |
5 | 0.28 | 180 | 13.99 | 410 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 36 | 13.97 | 571 | 6 | 6 |
2 | 978.72 | -1 | 13.97 | 571 | 6 | 6 |
3 | 1012.08 | 40 | 9.01 | 1765 | 6 | 7 |
4 | 865.00 | 38 | 13.09 | 1622 | 6 | 9 |
5 | 52.12 | 38 | 14.04 | 485 | 6 | 8 |
6 | 27.88 | 38 | 14.08 | 450 | 6 | 13 |
7 | 13.68 | 38 | 14.05 | 435 | 6 | 21 |
8 | 0.16 | 181 | 13.95 | 415 | 7 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.44 | 38 | 13.91 | 553 | 6 | 6 |
2 | 966.12 | -1 | 13.91 | 553 | 6 | 6 |
3 | 1150.88 | 14 | 12.18 | 2071 | 6 | 6 |
4 | 1590.88 | 50 | 11.83 | 2666 | 6 | 6 |
5 | 1590.04 | 40 | 10.96 | 2636 | 6 | 7 |
6 | 599.08 | 38 | 13.44 | 1229 | 6 | 9 |
7 | 0.08 | 181 | 14.06 | 392 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.96 | 36 | 14.04 | 553 | 6 | 7 |
2 | 1013.76 | 40 | 6.90 | 1727 | 6 | 6 |
3 | 906.24 | 38 | 12.95 | 1662 | 6 | 9 |
4 | 163.44 | 38 | 13.91 | 616 | 6 | 9 |
5 | -0.12 | 180 | 14.03 | 389 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.28 | 35 | 13.85 | 589 | 6 | 6 |
2 | 1031.48 | 1 | 12.12 | 1892 | 6 | 6 |
3 | 1018.56 | 40 | 7.56 | 1741 | 6 | 6 |
4 | 898.16 | 38 | 13.03 | 1617 | 6 | 8 |
5 | 157.56 | 38 | 13.90 | 610 | 6 | 9 |
6 | 0.16 | 181 | 14.02 | 400 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.68 | 36 | 14.04 | 589 | 6 | 6 |
2 | 975.64 | -1 | 14.04 | 589 | 6 | 6 |
3 | 1008.36 | 40 | 8.99 | 1748 | 6 | 7 |
4 | 865.76 | 38 | 13.04 | 1622 | 6 | 10 |
5 | 23.12 | 38 | 14.06 | 448 | 6 | 7 |
6 | 0.00 | 180 | 13.99 | 419 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.84 | 29 | 13.97 | 589 | 6 | 6 |
2 | 1021.24 | 5 | 13.34 | 1839 | 6 | 6 |
3 | 1060.56 | 4 | 13.34 | 2000 | 6 | 7 |
4 | 1047.76 | 1 | 12.51 | 1946 | 6 | 6 |
5 | 1174.76 | 14 | 12.39 | 2091 | 6 | 6 |
6 | 1576.32 | 50 | 12.05 | 2673 | 6 | 7 |
7 | 1574.52 | 40 | 11.12 | 2622 | 7 | 8 |
8 | 573.32 | 38 | 13.58 | 1174 | 6 | 9 |
9 | 0.32 | 181 | 14.06 | 415 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.96 | 36 | 14.04 | 589 | 6 | 6 |
2 | 1143.00 | 14 | 6.37 | 1972 | 6 | 6 |
3 | 2005.04 | 50 | 7.14 | 3171 | 6 | 6 |
4 | 2005.44 | 40 | 9.16 | 3167 | 6 | 6 |
5 | 1844.24 | 38 | 12.13 | 3042 | 6 | 7 |
6 | 1244.80 | 38 | 12.90 | 2144 | 6 | 11 |
7 | 86.24 | 37 | 14.04 | 542 | 6 | 9 |
8 | 0.64 | 181 | 14.06 | 417 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 36 | 14.04 | 589 | 6 | 7 |
2 | 1164.28 | 11 | 5.85 | 1935 | 6 | 6 |
3 | 2002.24 | 45 | 7.08 | 3203 | 6 | 6 |
4 | 2002.28 | 40 | 9.29 | 3140 | 6 | 6 |
5 | 1829.88 | 36 | 12.25 | 2965 | 6 | 7 |
6 | 1085.24 | 36 | 13.06 | 1951 | 6 | 10 |
7 | 124.52 | 36 | 13.99 | 596 | 6 | 8 |
8 | -0.08 | 181 | 14.07 | 416 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.32 | 35 | 14.04 | 571 | 6 | 6 |
2 | 1036.92 | 1 | 12.31 | 1875 | 6 | 6 |
3 | 1173.60 | 11 | 5.96 | 1949 | 6 | 6 |
4 | 2002.68 | 45 | 7.82 | 3234 | 6 | 6 |
5 | 2003.64 | 40 | 9.73 | 3182 | 6 | 6 |
6 | 1830.48 | 36 | 12.19 | 2960 | 6 | 7 |
7 | 1049.60 | 36 | 13.07 | 1883 | 6 | 10 |
8 | 54.12 | 36 | 14.12 | 487 | 6 | 8 |
9 | 0.12 | 181 | 14.07 | 424 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.36 | 36 | 14.04 | 571 | 6 | 7 |
2 | 955.92 | -1 | 14.04 | 571 | 6 | 7 |
3 | 1148.96 | 11 | 6.60 | 1946 | 6 | 6 |
4 | 2002.72 | 45 | 8.17 | 3267 | 6 | 6 |
5 | 2002.52 | 100 | 8.88 | 3200 | 6 | 6 |
6 | 1180.96 | 36 | 12.85 | 2082 | 6 | 12 |
7 | 75.48 | 36 | 14.04 | 515 | 6 | 8 |
8 | -0.32 | 181 | 14.05 | 418 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.12 | 35 | 14.04 | 589 | 6 | 7 |
2 | 1023.72 | 1 | 12.00 | 1857 | 6 | 6 |
3 | 1168.24 | 11 | 6.70 | 2045 | 6 | 6 |
4 | 2002.44 | 45 | 8.54 | 3231 | 6 | 6 |
5 | 2001.96 | 40 | 9.57 | 3150 | 6 | 6 |
6 | 1656.76 | 36 | 12.33 | 2780 | 6 | 7 |
7 | 877.32 | 36 | 13.27 | 1606 | 6 | 10 |
8 | 3.32 | 36 | 14.19 | 411 | 6 | 8 |
9 | 0.20 | 180 | 14.05 | 409 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.08 | 34 | 14.04 | 589 | 6 | 6 |
2 | 1024.52 | 1 | 12.25 | 1892 | 6 | 6 |
3 | 1161.88 | 11 | 6.72 | 1981 | 6 | 6 |
4 | 2001.60 | 45 | 8.65 | 3182 | 6 | 6 |
5 | 2001.52 | 40 | 9.62 | 3192 | 6 | 6 |
6 | 1642.96 | 36 | 12.39 | 2740 | 6 | 8 |
7 | 865.84 | 36 | 13.27 | 1601 | 6 | 10 |
8 | 0.12 | 181 | 14.05 | 417 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.88 | 35 | 14.04 | 571 | 6 | 6 |
2 | 964.24 | -1 | 14.04 | 571 | 6 | 6 |
3 | 1151.36 | 9 | 6.27 | 1932 | 6 | 6 |
4 | 2000.44 | 35 | 8.36 | 3181 | 6 | 6 |
5 | 2000.52 | 40 | 9.69 | 3168 | 6 | 6 |
6 | 1831.00 | 37 | 12.09 | 2941 | 6 | 6 |
7 | 1038.64 | 37 | 13.08 | 1819 | 6 | 9 |
8 | 89.16 | 37 | 14.08 | 518 | 6 | 9 |
9 | 0.12 | 181 | 14.10 | 401 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.60 | 35 | 13.97 | 607 | 6 | 6 |
2 | 1167.56 | 9 | 6.38 | 2030 | 6 | 6 |
3 | 2001.00 | 35 | 8.81 | 3236 | 6 | 6 |
4 | 2001.76 | 40 | 9.78 | 3195 | 6 | 6 |
5 | 1835.48 | 37 | 11.98 | 3021 | 6 | 7 |
6 | 1036.68 | 37 | 13.05 | 1843 | 6 | 10 |
7 | 83.28 | 37 | 14.08 | 520 | 6 | 8 |
8 | 0.00 | 181 | 14.07 | 412 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.12 | 35 | 14.04 | 571 | 6 | 6 |
2 | 1163.88 | 9 | 6.15 | 2053 | 6 | 6 |
3 | 2000.96 | 35 | 9.04 | 3223 | 6 | 6 |
4 | 2001.08 | 40 | 9.90 | 3178 | 6 | 6 |
5 | 1654.52 | 37 | 12.25 | 2776 | 6 | 8 |
6 | 873.44 | 37 | 13.22 | 1614 | 6 | 10 |
7 | 42.24 | 37 | 14.14 | 474 | 6 | 10 |
8 | 0.12 | 181 | 14.05 | 419 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.08 | 35 | 14.04 | 589 | 6 | 6 |
2 | 1021.60 | 1 | 11.94 | 1875 | 6 | 6 |
3 | 1183.96 | 9 | 6.72 | 2075 | 6 | 6 |
4 | 2001.24 | 35 | 9.65 | 3099 | 6 | 6 |
5 | 2001.08 | 40 | 10.00 | 3179 | 6 | 6 |
6 | 1645.88 | 37 | 12.33 | 2725 | 6 | 7 |
7 | 837.52 | 37 | 13.24 | 1572 | 6 | 10 |
8 | 0.16 | 180 | 14.08 | 402 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.48 | 36 | 14.04 | 589 | 6 | 7 |
2 | 980.92 | -1 | 14.04 | 589 | 6 | 7 |
3 | 1183.40 | 9 | 6.67 | 1990 | 6 | 6 |
4 | 2003.20 | 35 | 9.32 | 3221 | 6 | 6 |
5 | 2002.96 | 40 | 10.11 | 3206 | 6 | 6 |
6 | 1823.96 | 37 | 12.10 | 3003 | 6 | 7 |
7 | 833.92 | 37 | 13.25 | 1574 | 6 | 9 |
8 | 15.32 | 37 | 14.17 | 441 | 6 | 9 |
9 | -0.04 | 181 | 13.98 | 420 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.92 | 37 | 14.04 | 589 | 6 | 6 |
2 | 968.88 | -1 | 14.04 | 589 | 6 | 6 |
3 | 1152.16 | 9 | 7.42 | 1923 | 6 | 6 |
4 | 2000.36 | 35 | 9.44 | 3233 | 6 | 6 |
5 | 1999.96 | 40 | 10.17 | 3179 | 6 | 6 |
6 | 1641.00 | 37 | 12.36 | 2691 | 6 | 7 |
7 | 689.00 | 37 | 13.40 | 1336 | 6 | 10 |
8 | 0.12 | 181 | 14.04 | 419 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 36 | 13.97 | 607 | 6 | 6 |
2 | 1162.08 | 9 | 7.25 | 1986 | 6 | 6 |
3 | 2002.56 | 35 | 9.53 | 3233 | 6 | 6 |
4 | 2002.08 | 40 | 10.22 | 3156 | 6 | 6 |
5 | 1481.36 | 37 | 12.58 | 2444 | 6 | 7 |
6 | 704.12 | 37 | 13.38 | 1380 | 6 | 9 |
7 | 0.08 | 181 | 14.03 | 415 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.60 | 36 | 14.04 | 571 | 6 | 6 |
2 | 1018.04 | 1 | 11.56 | 1892 | 6 | 6 |
3 | 1165.68 | 8 | 7.57 | 1999 | 6 | 6 |
4 | 2002.96 | 35 | 9.62 | 3253 | 6 | 6 |
5 | 2002.64 | 40 | 10.28 | 3161 | 6 | 6 |
6 | 1634.04 | 37 | 12.39 | 2700 | 6 | 8 |
7 | 838.32 | 37 | 13.22 | 1573 | 6 | 11 |
8 | 9.16 | 37 | 14.18 | 426 | 6 | 12 |
9 | -0.16 | 181 | 14.01 | 418 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.24 | 35 | 14.04 | 589 | 6 | 6 |
2 | 1023.24 | 1 | 12.06 | 1910 | 6 | 6 |
3 | 1167.24 | 8 | 7.87 | 2004 | 6 | 6 |
4 | 2001.72 | 35 | 9.55 | 3277 | 6 | 6 |
5 | 2001.12 | 40 | 10.27 | 3202 | 6 | 6 |
6 | 1470.48 | 37 | 12.55 | 2485 | 6 | 8 |
7 | 694.88 | 37 | 13.42 | 1354 | 6 | 10 |
8 | 0.28 | 181 | 14.03 | 410 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.56 | 35 | 14.04 | 589 | 6 | 6 |
2 | 1159.16 | 6 | 7.19 | 1987 | 6 | 6 |
3 | 2000.72 | 35 | 9.57 | 3257 | 6 | 6 |
4 | 2000.48 | 40 | 10.22 | 3245 | 6 | 6 |
5 | 1481.04 | 37 | 12.57 | 2461 | 6 | 8 |
6 | 739.64 | 37 | 13.36 | 1400 | 6 | 10 |
7 | 21.56 | 37 | 14.15 | 437 | 6 | 10 |
8 | -0.08 | 181 | 14.02 | 407 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.72 | 36 | 14.04 | 589 | 6 | 6 |
2 | 967.36 | -1 | 14.04 | 589 | 6 | 6 |
3 | 1153.20 | 6 | 7.37 | 2035 | 6 | 6 |
4 | 2003.44 | 35 | 9.84 | 3175 | 6 | 6 |
5 | 2003.24 | 40 | 10.30 | 3220 | 6 | 6 |
6 | 1640.00 | 37 | 12.35 | 2700 | 6 | 8 |
7 | 669.52 | 37 | 13.43 | 1342 | 6 | 10 |
8 | 16.08 | 37 | 14.14 | 440 | 6 | 9 |
9 | 0.36 | 181 | 13.99 | 404 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.12 | 36 | 14.04 | 589 | 6 | 6 |
2 | 1027.40 | 1 | 12.25 | 1892 | 6 | 6 |
3 | 1160.88 | 6 | 7.64 | 2065 | 6 | 6 |
4 | 2001.00 | 35 | 9.77 | 3273 | 6 | 6 |
5 | 2000.24 | 40 | 10.36 | 3189 | 6 | 6 |
6 | 1627.84 | 37 | 12.40 | 2728 | 6 | 8 |
7 | 649.88 | 37 | 13.46 | 1288 | 6 | 9 |
8 | 14.44 | 37 | 14.15 | 450 | 6 | 11 |
9 | -0.36 | 181 | 13.96 | 424 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.96 | 37 | 14.04 | 571 | 6 | 6 |
2 | 960.64 | -1 | 14.04 | 571 | 6 | 6 |
3 | 1149.88 | 6 | 7.83 | 1963 | 6 | 6 |
4 | 2001.52 | 35 | 9.66 | 3285 | 6 | 6 |
5 | 2001.00 | 40 | 10.33 | 3201 | 6 | 6 |
6 | 1632.60 | 37 | 12.43 | 2674 | 6 | 8 |
7 | 651.16 | 37 | 13.47 | 1294 | 6 | 9 |
8 | 0.20 | 181 | 14.03 | 411 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.00 | 35 | 14.04 | 589 | 6 | 6 |
2 | 1050.72 | 1 | 12.89 | 1946 | 6 | 6 |
3 | 1186.28 | 6 | 8.42 | 1993 | 6 | 6 |
4 | 2000.64 | 35 | 10.19 | 3181 | 6 | 6 |
5 | 1999.76 | 40 | 10.41 | 3175 | 6 | 6 |
6 | 1622.00 | 37 | 12.43 | 2663 | 6 | 8 |
7 | 651.96 | 37 | 13.48 | 1279 | 6 | 9 |
8 | 0.20 | 181 | 14.07 | 397 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.88 | 37 | 13.97 | 571 | 6 | 6 |
2 | 945.24 | -2 | 13.97 | 571 | 6 | 6 |
3 | 1168.28 | 6 | 8.07 | 2077 | 6 | 6 |
4 | 2000.04 | 35 | 10.09 | 3174 | 6 | 6 |
5 | 1999.12 | 40 | 10.38 | 3175 | 6 | 6 |
6 | 1464.72 | 37 | 12.62 | 2451 | 6 | 8 |
7 | 684.96 | 37 | 13.43 | 1334 | 6 | 10 |
8 | 0.80 | 181 | 14.03 | 410 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.16 | 36 | 13.97 | 589 | 6 | 6 |
2 | 1045.44 | 1 | 12.63 | 1928 | 6 | 6 |
3 | 1169.92 | 6 | 8.79 | 2023 | 6 | 6 |
4 | 2001.44 | 35 | 10.12 | 3187 | 6 | 6 |
5 | 2000.76 | 40 | 10.48 | 3149 | 6 | 6 |
6 | 1627.20 | 37 | 12.49 | 2659 | 6 | 8 |
7 | 636.64 | 37 | 13.50 | 1260 | 6 | 10 |
8 | 0.00 | 180 | 14.05 | 406 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.56 | 36 | 14.04 | 589 | 6 | 6 |
2 | 1151.04 | 6 | 8.49 | 1940 | 6 | 6 |
3 | 2003.08 | 35 | 10.05 | 3140 | 6 | 6 |
4 | 2002.32 | 41 | 10.43 | 3182 | 6 | 6 |
5 | 1635.44 | 37 | 12.49 | 2699 | 6 | 8 |
6 | 644.92 | 37 | 13.48 | 1276 | 6 | 9 |
7 | 0.24 | 181 | 14.03 | 418 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 37 | 14.10 | 571 | 6 | 6 |
2 | 957.64 | -1 | 14.10 | 571 | 6 | 6 |
3 | 1141.20 | 6 | 7.98 | 2047 | 6 | 6 |
4 | 2004.12 | 35 | 10.00 | 3143 | 6 | 6 |
5 | 2003.76 | 40 | 10.30 | 3220 | 6 | 6 |
6 | 1476.04 | 37 | 12.60 | 2487 | 6 | 8 |
7 | 702.00 | 37 | 13.43 | 1365 | 6 | 9 |
8 | 0.08 | 181 | 14.07 | 406 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.12 | 35 | 13.97 | 589 | 6 | 6 |
2 | 1063.84 | 2 | 13.08 | 1928 | 6 | 6 |
3 | 1174.52 | 5 | 8.13 | 2065 | 6 | 6 |
4 | 2002.36 | 55 | 10.05 | 3156 | 6 | 6 |
5 | 1695.00 | 43 | 12.32 | 2775 | 6 | 7 |
6 | 771.80 | 43 | 13.34 | 1448 | 6 | 9 |
7 | 0.32 | 181 | 14.07 | 399 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.68 | 37 | 14.04 | 607 | 6 | 6 |
2 | 925.44 | -2 | 14.04 | 607 | 6 | 6 |
3 | 1151.52 | 5 | 8.47 | 1993 | 6 | 6 |
4 | 2002.44 | 55 | 9.98 | 3191 | 6 | 6 |
5 | 1849.72 | 43 | 12.09 | 3013 | 6 | 7 |
6 | 884.32 | 43 | 13.21 | 1635 | 6 | 9 |
7 | -0.16 | 180 | 14.05 | 412 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.92 | 34 | 14.04 | 589 | 6 | 6 |
2 | 1015.64 | 3 | 13.21 | 1892 | 6 | 7 |
3 | 1150.68 | 5 | 8.96 | 1999 | 6 | 6 |
4 | 2003.44 | 55 | 10.17 | 3159 | 6 | 6 |
5 | 1846.08 | 43 | 12.13 | 2950 | 6 | 7 |
6 | 732.88 | 43 | 13.36 | 1416 | 6 | 9 |
7 | 0.04 | 181 | 14.04 | 415 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.84 | 36 | 14.04 | 571 | 6 | 6 |
2 | 943.88 | -2 | 14.04 | 571 | 6 | 6 |
3 | 1165.56 | 5 | 9.47 | 2035 | 6 | 6 |
4 | 2001.68 | 55 | 10.19 | 3196 | 6 | 6 |
5 | 1683.60 | 43 | 12.26 | 2793 | 6 | 7 |
6 | 615.96 | 43 | 13.47 | 1252 | 6 | 10 |
7 | 16.76 | 43 | 14.17 | 438 | 6 | 10 |
8 | -0.08 | 181 | 13.94 | 420 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.00 | 36 | 14.04 | 571 | 6 | 6 |
2 | 1027.56 | 1 | 12.44 | 1892 | 6 | 6 |
3 | 1165.72 | 5 | 9.68 | 2005 | 6 | 6 |
4 | 2000.76 | 55 | 10.19 | 3197 | 6 | 6 |
5 | 1682.00 | 43 | 12.29 | 2766 | 6 | 8 |
6 | 761.68 | 43 | 13.31 | 1469 | 6 | 10 |
7 | 0.20 | 181 | 14.03 | 417 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.28 | 37 | 14.04 | 589 | 6 | 6 |
2 | 971.04 | -1 | 14.04 | 589 | 6 | 6 |
3 | 1170.92 | 5 | 9.60 | 2053 | 6 | 6 |
4 | 2001.84 | 55 | 10.20 | 3214 | 6 | 6 |
5 | 1682.52 | 43 | 12.31 | 2764 | 6 | 7 |
6 | 740.52 | 43 | 13.34 | 1432 | 6 | 10 |
7 | 20.00 | 43 | 14.17 | 451 | 6 | 10 |
8 | 0.12 | 181 | 14.01 | 419 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.40 | 37 | 13.97 | 571 | 6 | 6 |
2 | 1152.32 | 5 | 9.98 | 2005 | 6 | 6 |
3 | 2002.00 | 55 | 10.32 | 3216 | 6 | 6 |
4 | 1684.80 | 43 | 12.30 | 2762 | 6 | 7 |
5 | 742.08 | 43 | 13.31 | 1438 | 6 | 10 |
6 | -0.16 | 181 | 14.03 | 420 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 39 | 13.97 | 607 | 6 | 7 |
2 | 912.40 | -2 | 13.97 | 607 | 6 | 7 |
3 | 1140.20 | 5 | 10.17 | 1988 | 6 | 6 |
4 | 2003.04 | 55 | 10.26 | 3241 | 6 | 6 |
5 | 1687.52 | 43 | 12.26 | 2777 | 6 | 7 |
6 | 734.72 | 43 | 13.35 | 1398 | 6 | 9 |
7 | 0.00 | 181 | 14.03 | 415 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.12 | 35 | 14.10 | 553 | 6 | 6 |
2 | 1047.68 | 3 | 13.27 | 1982 | 6 | 7 |
3 | 1042.00 | 1 | 13.02 | 1892 | 6 | 6 |
4 | 1020.52 | 1 | 12.44 | 1875 | 6 | 6 |
5 | 1168.44 | 5 | 10.13 | 2047 | 6 | 6 |
6 | 2001.68 | 55 | 10.43 | 3181 | 6 | 6 |
7 | 1680.24 | 43 | 12.31 | 2691 | 6 | 7 |
8 | 723.80 | 43 | 13.38 | 1364 | 6 | 10 |
9 | 0.40 | 181 | 14.04 | 417 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.80 | 33 | 14.10 | 571 | 6 | 6 |
2 | 1003.80 | 3 | 13.40 | 1839 | 6 | 7 |
3 | 977.56 | -1 | 13.40 | 1839 | 6 | 7 |
4 | 1157.76 | 5 | 10.28 | 2011 | 6 | 6 |
5 | 2002.68 | 55 | 10.52 | 3159 | 6 | 6 |
6 | 1673.24 | 43 | 12.31 | 2703 | 6 | 7 |
7 | 710.80 | 43 | 13.37 | 1365 | 6 | 9 |
8 | -0.08 | 181 | 14.04 | 415 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.48 | 37 | 14.10 | 571 | 6 | 7 |
2 | 874.48 | -3 | 14.10 | 571 | 6 | 7 |
3 | 961.16 | -1 | 14.10 | 571 | 6 | 7 |
4 | 1143.48 | 5 | 10.34 | 2005 | 6 | 6 |
5 | 2002.88 | 55 | 10.37 | 3201 | 6 | 6 |
6 | 1678.88 | 43 | 12.30 | 2727 | 6 | 8 |
7 | 592.92 | 43 | 13.52 | 1194 | 6 | 10 |
8 | 0.72 | 181 | 14.05 | 407 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.44 | 35 | 14.10 | 571 | 6 | 6 |
2 | 1041.52 | 1 | 12.95 | 1928 | 6 | 6 |
3 | 1026.16 | 1 | 12.44 | 1946 | 6 | 6 |
4 | 1168.48 | 5 | 10.53 | 2011 | 6 | 6 |
5 | 1998.28 | 55 | 10.56 | 3179 | 6 | 6 |
6 | 1664.60 | 43 | 12.36 | 2683 | 6 | 8 |
7 | 708.88 | 43 | 13.39 | 1359 | 6 | 9 |
8 | 61.68 | 43 | 14.14 | 489 | 6 | 12 |
9 | -0.36 | 181 | 14.03 | 418 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.20 | 34 | 14.10 | 589 | 6 | 6 |
2 | 1044.16 | 1 | 12.95 | 1928 | 6 | 6 |
3 | 1168.40 | 5 | 10.34 | 2077 | 6 | 6 |
4 | 2003.72 | 55 | 10.54 | 3171 | 6 | 6 |
5 | 1682.64 | 43 | 12.29 | 2733 | 6 | 8 |
6 | 726.00 | 43 | 13.35 | 1372 | 6 | 10 |
7 | 0.12 | 181 | 14.05 | 400 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 34 | 14.10 | 589 | 6 | 6 |
2 | 1152.48 | 5 | 10.49 | 2005 | 6 | 6 |
3 | 2000.76 | 55 | 10.48 | 3212 | 6 | 6 |
4 | 1682.80 | 43 | 12.24 | 2768 | 6 | 7 |
5 | 732.84 | 43 | 13.30 | 1444 | 6 | 11 |
6 | -0.04 | 181 | 14.02 | 420 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.32 | 35 | 14.04 | 571 | 6 | 6 |
2 | 978.20 | -1 | 14.04 | 571 | 6 | 6 |
3 | 1160.52 | 5 | 10.68 | 1994 | 6 | 6 |
4 | 2000.88 | 55 | 10.52 | 3201 | 6 | 6 |
5 | 1672.36 | 43 | 12.27 | 2774 | 6 | 8 |
6 | 721.92 | 43 | 13.36 | 1394 | 6 | 9 |
7 | 9.68 | 43 | 14.19 | 413 | 6 | 13 |
8 | 0.08 | 181 | 13.96 | 412 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.96 | 35 | 13.85 | 589 | 6 | 6 |
2 | 1152.60 | 6 | 10.66 | 2005 | 6 | 6 |
3 | 2001.88 | 52 | 10.58 | 3206 | 6 | 6 |
4 | 1682.32 | 38 | 12.34 | 2776 | 6 | 7 |
5 | 765.08 | 38 | 13.34 | 1463 | 6 | 10 |
6 | 0.16 | 180 | 14.03 | 413 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.72 | 35 | 14.04 | 607 | 6 | 6 |
2 | 1143.80 | 6 | 10.60 | 1999 | 6 | 6 |
3 | 1988.00 | 52 | 10.62 | 3178 | 6 | 6 |
4 | 1520.08 | 38 | 12.51 | 2571 | 6 | 8 |
5 | 796.16 | 38 | 13.31 | 1484 | 6 | 9 |
6 | 42.52 | 38 | 14.14 | 470 | 6 | 9 |
7 | 0.44 | 181 | 14.01 | 413 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.88 | 35 | 14.10 | 589 | 6 | 6 |
2 | 1156.72 | 6 | 10.60 | 2017 | 6 | 6 |
3 | 2000.96 | 49 | 10.70 | 3171 | 6 | 6 |
4 | 1691.88 | 38 | 12.33 | 2806 | 6 | 7 |
5 | 788.36 | 38 | 13.34 | 1473 | 6 | 11 |
6 | 39.20 | 38 | 14.16 | 464 | 6 | 9 |
7 | -0.24 | 181 | 14.01 | 417 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.88 | 34 | 14.10 | 589 | 6 | 6 |
2 | 1164.72 | 6 | 10.70 | 2011 | 6 | 6 |
3 | 2011.64 | 49 | 10.79 | 3211 | 6 | 6 |
4 | 1856.84 | 38 | 12.21 | 2984 | 6 | 7 |
5 | 935.52 | 38 | 13.21 | 1644 | 6 | 9 |
6 | 17.00 | 38 | 14.21 | 402 | 6 | 9 |
7 | 0.48 | 181 | 13.97 | 413 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.48 | 33 | 14.04 | 589 | 6 | 6 |
2 | 1019.48 | 1 | 11.43 | 1892 | 6 | 6 |
3 | 1161.64 | 6 | 10.56 | 2017 | 6 | 6 |
4 | 2001.44 | 49 | 10.76 | 3187 | 6 | 6 |
5 | 1688.12 | 38 | 12.38 | 2734 | 6 | 7 |
6 | 951.36 | 38 | 13.19 | 1681 | 6 | 9 |
7 | 0.08 | 181 | 14.06 | 405 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.32 | 35 | 14.10 | 589 | 6 | 6 |
2 | 944.20 | -1 | 14.10 | 589 | 6 | 6 |
3 | 973.96 | -1 | 14.10 | 589 | 6 | 6 |
4 | 1161.72 | 6 | 10.43 | 2053 | 6 | 6 |
5 | 2000.68 | 49 | 10.79 | 3174 | 6 | 6 |
6 | 1844.16 | 38 | 12.16 | 3009 | 6 | 7 |
7 | 914.04 | 38 | 13.19 | 1683 | 6 | 8 |
8 | 15.04 | 38 | 14.23 | 435 | 6 | 8 |
9 | -0.32 | 181 | 13.97 | 416 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.84 | 35 | 14.04 | 589 | 6 | 6 |
2 | 1020.48 | 1 | 11.62 | 1875 | 6 | 6 |
3 | 1169.12 | 6 | 10.72 | 2017 | 6 | 6 |
4 | 2000.44 | 49 | 10.81 | 3186 | 6 | 6 |
5 | 1842.36 | 38 | 12.21 | 2976 | 6 | 7 |
6 | 908.00 | 38 | 13.23 | 1653 | 6 | 10 |
7 | 2.16 | 38 | 14.23 | 422 | 6 | 12 |
8 | 0.04 | 180 | 13.98 | 415 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.28 | 34 | 14.10 | 589 | 6 | 6 |
2 | 1177.40 | 6 | 10.58 | 2053 | 6 | 6 |
3 | 2004.36 | 49 | 10.93 | 3171 | 6 | 6 |
4 | 1689.24 | 38 | 12.43 | 2726 | 6 | 7 |
5 | 789.80 | 38 | 13.37 | 1465 | 6 | 11 |
6 | 0.24 | 180 | 14.04 | 412 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 35 | 13.97 | 607 | 6 | 6 |
2 | 973.92 | -1 | 13.97 | 607 | 6 | 6 |
3 | 1161.44 | 6 | 10.53 | 2041 | 6 | 6 |
4 | 2000.36 | 49 | 10.91 | 3194 | 6 | 6 |
5 | 1684.00 | 38 | 12.35 | 2762 | 6 | 7 |
6 | 792.12 | 38 | 13.36 | 1473 | 6 | 11 |
7 | 0.12 | 181 | 14.05 | 408 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.48 | 36 | 13.97 | 589 | 6 | 6 |
2 | 974.68 | -1 | 13.97 | 589 | 6 | 6 |
3 | 1158.80 | 6 | 10.64 | 2023 | 6 | 6 |
4 | 2002.52 | 49 | 10.97 | 3166 | 6 | 6 |
5 | 1842.04 | 38 | 12.22 | 2999 | 6 | 7 |
6 | 896.64 | 38 | 13.25 | 1617 | 6 | 9 |
7 | 10.96 | 38 | 14.21 | 424 | 6 | 9 |
8 | 0.00 | 181 | 13.97 | 411 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.16 | 36 | 14.04 | 607 | 6 | 6 |
2 | 1180.08 | 6 | 10.51 | 2095 | 6 | 6 |
3 | 2002.84 | 49 | 10.94 | 3196 | 6 | 6 |
4 | 1688.76 | 38 | 12.32 | 2837 | 6 | 7 |
5 | 948.92 | 38 | 13.20 | 1711 | 6 | 10 |
6 | 0.60 | 180 | 14.04 | 413 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.72 | 35 | 13.91 | 607 | 6 | 6 |
2 | 1018.64 | 1 | 11.49 | 1892 | 6 | 6 |
3 | 1163.04 | 6 | 10.51 | 2047 | 6 | 6 |
4 | 2001.36 | 49 | 11.07 | 3151 | 6 | 6 |
5 | 1687.12 | 38 | 12.45 | 2705 | 6 | 7 |
6 | 779.16 | 38 | 13.39 | 1455 | 6 | 9 |
7 | 18.28 | 38 | 14.15 | 453 | 6 | 7 |
8 | 0.00 | 180 | 13.97 | 423 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.32 | 35 | 14.10 | 571 | 6 | 6 |
2 | 1139.04 | 6 | 10.36 | 1982 | 6 | 6 |
3 | 2001.44 | 49 | 10.97 | 3214 | 6 | 6 |
4 | 1671.96 | 38 | 12.42 | 2763 | 6 | 7 |
5 | 938.88 | 38 | 13.25 | 1689 | 6 | 9 |
6 | 0.08 | 181 | 14.02 | 424 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.60 | 36 | 14.17 | 571 | 6 | 6 |
2 | 968.92 | -1 | 14.17 | 571 | 6 | 6 |
3 | 1154.44 | 3 | 9.51 | 2035 | 6 | 6 |
4 | 2001.56 | 52 | 10.90 | 3220 | 6 | 6 |
5 | 1679.00 | 38 | 12.47 | 2799 | 6 | 7 |
6 | 783.60 | 38 | 13.42 | 1474 | 6 | 10 |
7 | 3.40 | 38 | 14.26 | 412 | 6 | 9 |
8 | -0.04 | 180 | 14.01 | 411 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 36 | 14.10 | 571 | 6 | 6 |
2 | 1147.00 | 3 | 8.81 | 1964 | 6 | 6 |
3 | 2003.12 | 52 | 11.01 | 3178 | 6 | 6 |
4 | 1843.32 | 38 | 12.33 | 2999 | 6 | 7 |
5 | 918.36 | 38 | 13.32 | 1640 | 6 | 10 |
6 | 0.52 | 181 | 14.10 | 405 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.56 | 37 | 14.10 | 589 | 6 | 7 |
2 | 965.56 | -1 | 14.10 | 589 | 6 | 7 |
3 | 1174.72 | 3 | 9.16 | 2044 | 6 | 6 |
4 | 2008.36 | 52 | 11.08 | 3205 | 6 | 6 |
5 | 1687.08 | 38 | 12.52 | 2767 | 6 | 7 |
6 | 796.52 | 38 | 13.41 | 1504 | 6 | 9 |
7 | 0.16 | 180 | 14.11 | 397 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.92 | 35 | 14.04 | 571 | 6 | 6 |
2 | 1052.16 | 1 | 12.95 | 1928 | 6 | 7 |
3 | 1027.32 | 1 | 12.95 | 1875 | 6 | 6 |
4 | 1174.64 | 3 | 10.09 | 1990 | 6 | 6 |
5 | 2003.88 | 52 | 11.10 | 3158 | 6 | 6 |
6 | 1555.16 | 38 | 12.62 | 2538 | 6 | 7 |
7 | 810.12 | 38 | 13.36 | 1499 | 6 | 10 |
8 | 0.96 | 181 | 14.04 | 415 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.40 | 36 | 14.10 | 589 | 6 | 6 |
2 | 950.12 | -1 | 14.10 | 589 | 6 | 6 |
3 | 1158.04 | 3 | 9.83 | 1999 | 6 | 6 |
4 | 2001.24 | 52 | 11.12 | 3192 | 6 | 6 |
5 | 1677.16 | 38 | 12.49 | 2762 | 6 | 7 |
6 | 787.04 | 38 | 13.41 | 1470 | 6 | 10 |
7 | 0.48 | 181 | 14.00 | 424 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.84 | 36 | 14.10 | 589 | 6 | 6 |
2 | 1162.72 | 3 | 9.89 | 1990 | 6 | 6 |
3 | 2000.88 | 52 | 11.10 | 3185 | 6 | 6 |
4 | 1680.00 | 38 | 12.54 | 2692 | 6 | 7 |
5 | 773.32 | 38 | 13.41 | 1448 | 6 | 10 |
6 | 29.44 | 38 | 14.21 | 461 | 6 | 8 |
7 | 15.48 | 38 | 14.08 | 441 | 6 | 11 |
8 | -0.40 | 181 | 13.91 | 411 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 40 | 14.10 | 571 | 6 | 7 |
2 | 886.32 | -3 | 14.10 | 571 | 6 | 7 |
3 | 971.80 | -1 | 14.10 | 571 | 6 | 7 |
4 | 1159.24 | 3 | 9.93 | 2017 | 6 | 6 |
5 | 2001.08 | 52 | 11.15 | 3210 | 6 | 6 |
6 | 1697.80 | 38 | 12.53 | 2741 | 6 | 8 |
7 | 937.56 | 38 | 13.25 | 1680 | 6 | 10 |
8 | 34.84 | 38 | 14.18 | 480 | 6 | 9 |
9 | 0.20 | 181 | 13.99 | 425 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 37 | 14.10 | 589 | 6 | 6 |
2 | 1087.68 | 2 | 13.21 | 1982 | 6 | 7 |
3 | 1029.72 | 1 | 13.02 | 1892 | 6 | 6 |
4 | 1178.80 | 3 | 9.93 | 2017 | 6 | 6 |
5 | 2005.12 | 52 | 11.21 | 3180 | 6 | 6 |
6 | 1674.64 | 38 | 12.58 | 2675 | 6 | 8 |
7 | 769.24 | 38 | 13.42 | 1443 | 6 | 9 |
8 | 0.24 | 181 | 14.03 | 413 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.20 | 37 | 14.04 | 607 | 6 | 6 |
2 | 1143.80 | 3 | 9.67 | 2044 | 6 | 6 |
3 | 2002.20 | 52 | 11.15 | 3225 | 6 | 6 |
4 | 1670.76 | 38 | 12.56 | 2731 | 6 | 8 |
5 | 755.08 | 38 | 13.41 | 1432 | 6 | 9 |
6 | 0.00 | 181 | 14.01 | 421 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.84 | 36 | 14.10 | 589 | 6 | 6 |
2 | 1162.96 | 3 | 9.96 | 2026 | 6 | 6 |
3 | 2001.68 | 52 | 11.23 | 3185 | 6 | 6 |
4 | 1686.52 | 38 | 12.52 | 2740 | 6 | 7 |
5 | 766.56 | 38 | 13.41 | 1444 | 6 | 9 |
6 | 13.80 | 38 | 14.23 | 422 | 6 | 8 |
7 | 0.04 | 181 | 13.92 | 427 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.36 | 36 | 14.04 | 589 | 6 | 6 |
2 | 1143.84 | 3 | 9.83 | 1999 | 6 | 6 |
3 | 2000.76 | 52 | 11.24 | 3194 | 6 | 6 |
4 | 1680.56 | 38 | 12.55 | 2754 | 6 | 7 |
5 | 759.16 | 38 | 13.43 | 1411 | 6 | 9 |
6 | 0.24 | 181 | 14.02 | 414 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.04 | 38 | 14.04 | 589 | 6 | 6 |
2 | 934.92 | -2 | 14.04 | 589 | 6 | 6 |
3 | 1148.16 | 3 | 9.89 | 2017 | 6 | 6 |
4 | 2002.72 | 52 | 11.24 | 3215 | 6 | 6 |
5 | 1679.56 | 38 | 12.50 | 2785 | 6 | 8 |
6 | 754.88 | 38 | 13.42 | 1433 | 6 | 9 |
7 | 32.64 | 38 | 14.19 | 460 | 6 | 8 |
8 | -0.12 | 181 | 13.98 | 422 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.92 | 39 | 14.04 | 589 | 6 | 6 |
2 | 979.76 | -1 | 14.04 | 589 | 6 | 6 |
3 | 1162.72 | 3 | 9.58 | 2035 | 6 | 6 |
4 | 2004.48 | 52 | 11.24 | 3222 | 6 | 6 |
5 | 1675.32 | 35 | 12.60 | 2750 | 6 | 7 |
6 | 777.64 | 35 | 13.43 | 1469 | 6 | 9 |
7 | 22.96 | 35 | 14.21 | 446 | 6 | 8 |
8 | 0.12 | 181 | 13.98 | 424 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.96 | 36 | 14.04 | 571 | 6 | 6 |
2 | 1078.44 | 2 | 13.21 | 1910 | 6 | 6 |
3 | 1035.12 | 1 | 13.21 | 1892 | 6 | 6 |
4 | 1166.72 | 3 | 9.86 | 2008 | 6 | 6 |
5 | 2004.84 | 52 | 11.38 | 3179 | 6 | 6 |
6 | 1670.76 | 35 | 12.60 | 2743 | 6 | 8 |
7 | 922.28 | 35 | 13.33 | 1647 | 6 | 9 |
8 | 31.20 | 35 | 14.19 | 466 | 6 | 7 |
9 | 0.36 | 181 | 13.98 | 428 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.60 | 39 | 14.04 | 589 | 6 | 6 |
2 | 919.92 | -2 | 14.04 | 589 | 6 | 6 |
3 | 1149.00 | 3 | 9.90 | 2008 | 6 | 6 |
4 | 2004.24 | 52 | 11.28 | 3196 | 6 | 6 |
5 | 1844.52 | 35 | 12.46 | 2993 | 6 | 7 |
6 | 877.24 | 35 | 13.34 | 1609 | 6 | 10 |
7 | 0.44 | 180 | 14.01 | 422 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.56 | 36 | 14.10 | 589 | 6 | 6 |
2 | 1009.52 | 3 | 13.53 | 1910 | 6 | 7 |
3 | 1132.72 | 3 | 9.80 | 1964 | 6 | 6 |
4 | 2002.52 | 52 | 11.39 | 3181 | 6 | 6 |
5 | 1515.20 | 35 | 12.78 | 2516 | 6 | 9 |
6 | 785.64 | 35 | 13.45 | 1449 | 6 | 9 |
7 | 90.96 | 35 | 14.13 | 529 | 6 | 7 |
8 | 0.36 | 181 | 14.01 | 428 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.52 | 35 | 14.10 | 589 | 6 | 6 |
2 | 1033.36 | 1 | 12.89 | 1928 | 6 | 6 |
3 | 1139.60 | 3 | 9.67 | 1981 | 6 | 6 |
4 | 2005.24 | 52 | 11.41 | 3190 | 6 | 6 |
5 | 1664.36 | 35 | 12.68 | 2695 | 6 | 7 |
6 | 746.88 | 35 | 13.46 | 1421 | 6 | 9 |
7 | 73.36 | 35 | 14.14 | 511 | 6 | 7 |
8 | -0.44 | 181 | 14.01 | 424 | 6 | 38 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.56 | 32 | 14.23 | 571 | 6 | 6 |
2 | 1065.24 | 2 | 13.14 | 1928 | 6 | 7 |
3 | 1157.44 | 3 | 9.35 | 1981 | 6 | 6 |
4 | 2001.36 | 52 | 11.45 | 3164 | 6 | 6 |
5 | 1684.24 | 35 | 12.71 | 2671 | 6 | 8 |
6 | 774.32 | 35 | 13.49 | 1439 | 6 | 9 |
7 | 0.56 | 181 | 14.06 | 421 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.08 | 37 | 14.17 | 571 | 6 | 6 |
2 | 882.08 | -3 | 14.17 | 571 | 6 | 6 |
3 | 975.88 | -1 | 14.17 | 571 | 6 | 6 |
4 | 1211.56 | 3 | 9.74 | 2080 | 6 | 6 |
5 | 2003.52 | 52 | 11.41 | 3179 | 6 | 6 |
6 | 1682.36 | 35 | 12.64 | 2781 | 6 | 7 |
7 | 932.32 | 35 | 13.33 | 1689 | 6 | 11 |
8 | 6.28 | 35 | 14.27 | 413 | 6 | 10 |
9 | -0.04 | 181 | 14.01 | 411 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.68 | 35 | 14.10 | 589 | 6 | 6 |
2 | 1027.92 | 1 | 12.70 | 1928 | 6 | 6 |
3 | 1161.36 | 3 | 9.55 | 2017 | 6 | 6 |
4 | 2003.60 | 52 | 11.46 | 3200 | 6 | 7 |
5 | 1532.52 | 35 | 12.79 | 2514 | 6 | 8 |
6 | 815.88 | 35 | 13.43 | 1501 | 6 | 9 |
7 | 50.84 | 35 | 14.20 | 496 | 6 | 8 |
8 | 0.12 | 181 | 14.01 | 426 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.60 | 33 | 14.10 | 607 | 6 | 6 |
2 | 1077.28 | 3 | 13.59 | 1982 | 6 | 7 |
3 | 1150.76 | 3 | 9.58 | 1981 | 6 | 6 |
4 | 2000.40 | 52 | 11.46 | 3188 | 6 | 6 |
5 | 1677.16 | 35 | 12.70 | 2730 | 6 | 7 |
6 | 914.40 | 35 | 13.34 | 1627 | 6 | 9 |
7 | 34.32 | 35 | 14.23 | 449 | 6 | 8 |
8 | -0.20 | 181 | 14.02 | 409 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.04 | 33 | 14.23 | 571 | 6 | 6 |
2 | 1121.36 | 3 | 8.94 | 1955 | 6 | 6 |
3 | 2006.96 | 52 | 11.34 | 3238 | 6 | 7 |
4 | 1532.60 | 35 | 12.81 | 2546 | 6 | 8 |
5 | 621.08 | 35 | 13.62 | 1230 | 6 | 9 |
6 | 0.24 | 181 | 14.04 | 416 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.52 | 34 | 14.17 | 571 | 6 | 6 |
2 | 954.00 | -1 | 14.17 | 571 | 6 | 6 |
3 | 1131.08 | 3 | 8.49 | 1955 | 6 | 6 |
4 | 2000.92 | 52 | 11.22 | 3243 | 6 | 6 |
5 | 1674.44 | 35 | 12.72 | 2749 | 6 | 8 |
6 | 769.24 | 35 | 13.51 | 1449 | 6 | 9 |
7 | 40.12 | 35 | 14.23 | 462 | 6 | 9 |
8 | -0.04 | 181 | 14.04 | 423 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.00 | 33 | 14.23 | 607 | 6 | 6 |
2 | 1021.08 | 1 | 12.19 | 1892 | 6 | 6 |
3 | 1147.36 | 3 | 8.52 | 1990 | 6 | 6 |
4 | 2002.00 | 52 | 11.23 | 3242 | 6 | 7 |
5 | 1671.88 | 35 | 12.73 | 2760 | 6 | 7 |
6 | 926.52 | 35 | 13.38 | 1674 | 6 | 11 |
7 | 10.20 | 35 | 14.28 | 429 | 6 | 9 |
8 | -0.08 | 181 | 14.02 | 417 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.20 | 32 | 14.23 | 571 | 6 | 6 |
2 | 1034.76 | 1 | 13.08 | 1910 | 6 | 6 |
3 | 1163.04 | 3 | 8.43 | 1955 | 6 | 6 |
4 | 2004.20 | 50 | 11.19 | 3229 | 6 | 7 |
5 | 1843.76 | 34 | 12.62 | 2919 | 6 | 9 |
6 | 921.92 | 35 | 13.39 | 1641 | 6 | 9 |
7 | 0.80 | 181 | 14.13 | 408 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.12 | 34 | 14.23 | 589 | 6 | 6 |
2 | 930.56 | -2 | 14.23 | 589 | 6 | 6 |
3 | 1159.16 | 3 | 8.30 | 1973 | 6 | 6 |
4 | 2002.16 | 50 | 11.12 | 3256 | 6 | 6 |
5 | 1685.72 | 34 | 12.74 | 2744 | 6 | 7 |
6 | 795.04 | 35 | 13.48 | 1490 | 6 | 11 |
7 | 9.36 | 35 | 14.35 | 411 | 6 | 9 |
8 | 0.12 | 181 | 14.06 | 410 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.92 | 32 | 14.23 | 607 | 6 | 6 |
2 | 1054.92 | 2 | 13.34 | 1982 | 6 | 7 |
3 | 1019.28 | 1 | 12.38 | 1964 | 6 | 6 |
4 | 1173.36 | 3 | 8.30 | 1982 | 6 | 6 |
5 | 2004.20 | 50 | 11.13 | 3237 | 6 | 7 |
6 | 1692.32 | 34 | 12.74 | 2724 | 6 | 7 |
7 | 956.00 | 35 | 13.35 | 1704 | 6 | 9 |
8 | 39.24 | 35 | 14.30 | 469 | 6 | 9 |
9 | 0.44 | 181 | 14.11 | 414 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.68 | 33 | 14.23 | 571 | 6 | 6 |
2 | 958.04 | -1 | 14.23 | 571 | 6 | 6 |
3 | 1146.52 | 3 | 8.17 | 1955 | 6 | 6 |
4 | 2004.56 | 50 | 11.13 | 3222 | 6 | 6 |
5 | 1675.88 | 34 | 12.76 | 2759 | 6 | 8 |
6 | 936.44 | 35 | 13.38 | 1698 | 6 | 9 |
7 | -0.12 | 181 | 14.12 | 415 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.60 | 32 | 14.23 | 589 | 6 | 6 |
2 | 1041.36 | 1 | 12.95 | 1982 | 6 | 6 |
3 | 1127.32 | 3 | 7.89 | 1928 | 6 | 6 |
4 | 2001.00 | 50 | 11.15 | 3221 | 6 | 6 |
5 | 1597.44 | 34 | 12.83 | 2625 | 6 | 8 |
6 | 713.40 | 35 | 13.58 | 1350 | 6 | 8 |
7 | 56.36 | 35 | 14.26 | 493 | 6 | 10 |
8 | 0.04 | 180 | 14.13 | 417 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.84 | 33 | 14.29 | 589 | 6 | 6 |
2 | 957.92 | -1 | 14.29 | 589 | 6 | 6 |
3 | 1103.12 | 3 | 7.50 | 1946 | 6 | 6 |
4 | 1990.80 | 50 | 11.10 | 3191 | 6 | 6 |
5 | 1592.40 | 34 | 12.81 | 2647 | 6 | 8 |
6 | 716.36 | 34 | 13.59 | 1402 | 6 | 9 |
7 | 0.16 | 181 | 14.14 | 416 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.36 | 33 | 14.29 | 571 | 6 | 6 |
2 | 1103.28 | 3 | 7.57 | 1901 | 6 | 6 |
3 | 2000.32 | 50 | 11.04 | 3181 | 6 | 6 |
4 | 1605.36 | 34 | 12.80 | 2665 | 6 | 8 |
5 | 732.76 | 35 | 13.55 | 1442 | 6 | 10 |
6 | 27.92 | 35 | 14.33 | 452 | 6 | 9 |
7 | 16.60 | 35 | 14.19 | 451 | 6 | 14 |
8 | -0.08 | 181 | 14.03 | 418 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.52 | 33 | 14.29 | 589 | 6 | 6 |
2 | 1113.40 | 3 | 7.66 | 1937 | 6 | 6 |
3 | 1989.76 | 5 | 9.55 | 3297 | 6 | 6 |
4 | 1989.76 | 50 | 11.17 | 3197 | 6 | 6 |
5 | 1575.12 | 30 | 12.90 | 2645 | 6 | 8 |
6 | 715.00 | 30 | 13.66 | 1384 | 6 | 9 |
7 | 14.52 | 30 | 14.34 | 425 | 6 | 8 |
8 | 0.24 | 181 | 14.09 | 417 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.44 | 33 | 14.23 | 607 | 6 | 6 |
2 | 1116.84 | 3 | 8.04 | 1901 | 6 | 6 |
3 | 1992.04 | 5 | 9.45 | 3434 | 6 | 6 |
4 | 1992.12 | 50 | 11.20 | 3191 | 6 | 6 |
5 | 1400.20 | 30 | 13.05 | 2377 | 6 | 8 |
6 | 772.32 | 30 | 13.57 | 1462 | 6 | 9 |
7 | 31.32 | 30 | 14.33 | 458 | 6 | 8 |
8 | -0.12 | 181 | 14.14 | 412 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.88 | 33 | 14.29 | 589 | 6 | 6 |
2 | 1100.52 | 3 | 8.07 | 1910 | 6 | 6 |
3 | 1991.72 | 5 | 9.41 | 3446 | 6 | 6 |
4 | 1991.76 | 50 | 11.21 | 3226 | 6 | 6 |
5 | 1391.92 | 30 | 13.06 | 2364 | 6 | 9 |
6 | 744.36 | 30 | 13.62 | 1438 | 6 | 9 |
7 | 25.20 | 30 | 14.34 | 452 | 6 | 8 |
8 | 0.12 | 181 | 14.14 | 415 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.16 | 33 | 14.29 | 571 | 6 | 6 |
2 | 1129.32 | 3 | 7.95 | 1937 | 6 | 6 |
3 | 1983.64 | 5 | 9.64 | 3142 | 6 | 6 |
4 | 1983.64 | 50 | 11.21 | 3203 | 6 | 6 |
5 | 1402.56 | 30 | 13.05 | 2388 | 6 | 9 |
6 | 773.56 | 30 | 13.62 | 1472 | 6 | 8 |
7 | 13.92 | 30 | 14.37 | 428 | 6 | 8 |
8 | 0.40 | 181 | 14.08 | 418 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.80 | 34 | 14.29 | 571 | 6 | 6 |
2 | 962.00 | -1 | 14.29 | 571 | 6 | 6 |
3 | 1122.28 | 3 | 7.95 | 1910 | 6 | 6 |
4 | 1976.16 | 5 | 9.20 | 3404 | 6 | 6 |
5 | 1976.24 | 50 | 11.21 | 3206 | 6 | 6 |
6 | 1556.36 | 30 | 12.93 | 2588 | 6 | 8 |
7 | 865.88 | 30 | 13.54 | 1609 | 6 | 9 |
8 | 37.12 | 30 | 14.33 | 476 | 6 | 8 |
9 | -0.20 | 180 | 14.15 | 402 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.72 | 34 | 14.29 | 589 | 6 | 6 |
2 | 1112.64 | 3 | 8.21 | 1901 | 6 | 6 |
3 | 1983.12 | 5 | 9.83 | 3208 | 6 | 6 |
4 | 1983.08 | 50 | 11.22 | 3192 | 6 | 6 |
5 | 1569.64 | 30 | 12.98 | 2599 | 6 | 8 |
6 | 695.20 | 30 | 13.67 | 1358 | 6 | 8 |
7 | 11.76 | 30 | 14.39 | 432 | 6 | 7 |
8 | 0.20 | 181 | 14.10 | 402 | 6 | 38 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.64 | 35 | 14.23 | 571 | 6 | 6 |
2 | 974.12 | -1 | 14.23 | 571 | 6 | 6 |
3 | 2002.20 | 21 | 11.59 | 357 | 6 | 6 |
4 | 2003.88 | 50 | 10.89 | 3413 | 6 | 6 |
5 | 1828.52 | 25 | 12.90 | 3004 | 6 | 7 |
6 | 1207.28 | 25 | 13.38 | 2060 | 6 | 9 |
7 | 589.36 | 25 | 13.81 | 1233 | 6 | 10 |
8 | 5.80 | 25 | 14.37 | 433 | 6 | 11 |
9 | 0.16 | 181 | 14.10 | 423 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.04 | 34 | 14.29 | 571 | 6 | 6 |
2 | 1028.72 | 1 | 12.89 | 1946 | 6 | 6 |
3 | 2008.20 | 21 | 11.57 | 390 | 6 | 6 |
4 | 2009.64 | 50 | 11.11 | 3476 | 6 | 6 |
5 | 1840.32 | 25 | 12.97 | 2992 | 6 | 8 |
6 | 1430.84 | 26 | 13.20 | 2419 | 6 | 8 |
7 | 760.12 | 25 | 13.66 | 1471 | 6 | 10 |
8 | 3.60 | 25 | 14.33 | 417 | 6 | 8 |
9 | 0.08 | 181 | 14.11 | 409 | 6 | 42 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.88 | 33 | 14.29 | 589 | 6 | 6 |
2 | 1023.24 | 1 | 12.38 | 1875 | 6 | 6 |
3 | 2001.40 | 21 | 11.71 | 359 | 6 | 6 |
4 | 2003.12 | 50 | 11.16 | 3336 | 6 | 6 |
5 | 1825.96 | 26 | 12.88 | 2928 | 6 | 7 |
6 | 1188.56 | 25 | 13.39 | 2022 | 6 | 10 |
7 | 546.36 | 25 | 13.88 | 1176 | 6 | 9 |
8 | 0.12 | 180 | 14.18 | 398 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.52 | 35 | 14.29 | 571 | 6 | 6 |
2 | 944.60 | -1 | 14.29 | 571 | 6 | 6 |
3 | 978.00 | -1 | 14.29 | 571 | 6 | 6 |
4 | 2003.48 | 21 | 11.71 | 359 | 6 | 6 |
5 | 2005.24 | 50 | 11.24 | 3390 | 6 | 6 |
6 | 1822.84 | 25 | 12.96 | 2985 | 6 | 7 |
7 | 1218.44 | 25 | 13.37 | 2117 | 6 | 10 |
8 | 587.60 | 25 | 13.83 | 1267 | 6 | 10 |
9 | 31.52 | 25 | 14.33 | 474 | 6 | 9 |
10 | 0.04 | 181 | 14.14 | 423 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.00 | 34 | 14.29 | 571 | 6 | 6 |
2 | 1034.72 | 1 | 13.14 | 1928 | 6 | 6 |
3 | 2002.20 | 21 | 11.74 | 361 | 6 | 6 |
4 | 2003.76 | 50 | 11.42 | 3314 | 6 | 6 |
5 | 1819.56 | 25 | 12.97 | 2994 | 6 | 7 |
6 | 1187.72 | 25 | 13.43 | 2067 | 6 | 9 |
7 | 551.16 | 25 | 13.87 | 1201 | 6 | 9 |
8 | -0.12 | 181 | 14.16 | 410 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.44 | 34 | 14.29 | 553 | 6 | 6 |
2 | 2002.32 | 21 | 11.95 | 355 | 6 | 6 |
3 | 2004.08 | 50 | 11.64 | 3213 | 6 | 7 |
4 | 1818.52 | 25 | 13.02 | 2965 | 6 | 7 |
5 | 1186.92 | 25 | 13.43 | 2004 | 6 | 9 |
6 | 554.80 | 25 | 13.91 | 1163 | 6 | 9 |
7 | 0.16 | 181 | 14.16 | 400 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.28 | 31 | 14.36 | 553 | 6 | 6 |
2 | 1000.20 | 3 | 14.04 | 1857 | 6 | 7 |
3 | 2009.00 | 21 | 12.00 | 368 | 6 | 6 |
4 | 2010.60 | 50 | 11.50 | 3335 | 6 | 6 |
5 | 1817.28 | 25 | 13.01 | 2949 | 6 | 7 |
6 | 1188.28 | 25 | 13.45 | 2003 | 6 | 9 |
7 | 578.56 | 25 | 13.86 | 1232 | 6 | 10 |
8 | 1.68 | 25 | 14.41 | 406 | 6 | 11 |
9 | 0.12 | 180 | 14.13 | 398 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.00 | 34 | 14.23 | 607 | 6 | 6 |
2 | 906.40 | -2 | 14.23 | 607 | 6 | 6 |
3 | 965.52 | -1 | 14.23 | 607 | 6 | 6 |
4 | 2000.52 | 21 | 12.05 | 408 | 6 | 6 |
5 | 2002.04 | 50 | 11.66 | 3377 | 6 | 6 |
6 | 1819.76 | 25 | 13.02 | 2955 | 6 | 7 |
7 | 1168.00 | 25 | 13.48 | 1992 | 6 | 9 |
8 | 543.28 | 25 | 13.91 | 1174 | 6 | 10 |
9 | 2.96 | 25 | 14.36 | 419 | 6 | 9 |
10 | 0.16 | 180 | 14.11 | 399 | 6 | 34 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.96 | 33 | 14.29 | 553 | 6 | 6 |
2 | 1039.92 | 1 | 13.85 | 1946 | 6 | 7 |
3 | 1017.36 | 1 | 12.95 | 1875 | 6 | 6 |
4 | 2001.04 | 21 | 12.25 | 404 | 6 | 6 |
5 | 2002.56 | 50 | 11.88 | 3352 | 6 | 6 |
6 | 1817.12 | 25 | 13.00 | 2963 | 6 | 8 |
7 | 1167.44 | 25 | 13.44 | 2078 | 6 | 10 |
8 | 513.80 | 25 | 13.90 | 1149 | 6 | 10 |
9 | 70.76 | 25 | 14.30 | 531 | 6 | 10 |
10 | 15.84 | 25 | 14.36 | 462 | 6 | 10 |
11 | -0.16 | 181 | 14.08 | 418 | 6 | 38 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.20 | 33 | 14.29 | 571 | 6 | 6 |
2 | 979.00 | -1 | 14.29 | 571 | 6 | 6 |
3 | 1126.24 | 8 | 11.40 | 1981 | 6 | 6 |
4 | 1843.96 | 30 | 11.93 | 3026 | 6 | 6 |
5 | 1842.24 | 50 | 11.60 | 3022 | 6 | 7 |
6 | 690.64 | 25 | 13.76 | 1390 | 6 | 9 |
7 | 72.04 | 25 | 14.30 | 544 | 6 | 9 |
8 | 0.00 | 191 | 14.14 | 414 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.08 | 33 | 14.29 | 553 | 6 | 6 |
2 | 1110.76 | 8 | 11.71 | 1955 | 6 | 6 |
3 | 1838.72 | 30 | 12.02 | 3057 | 6 | 6 |
4 | 1837.40 | 50 | 11.67 | 3011 | 6 | 7 |
5 | 655.96 | 25 | 13.77 | 1322 | 6 | 10 |
6 | 22.60 | 25 | 14.36 | 462 | 6 | 9 |
7 | 0.04 | 191 | 14.10 | 402 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 33 | 14.23 | 571 | 6 | 6 |
2 | 2009.88 | 4 | 11.17 | 357 | 6 | 6 |
3 | 2010.72 | 30 | 12.17 | 3410 | 6 | 6 |
4 | 1864.20 | 25 | 13.01 | 3053 | 6 | 7 |
5 | 1667.24 | 25 | 13.13 | 2753 | 6 | 9 |
6 | 1009.36 | 25 | 13.54 | 1810 | 6 | 9 |
7 | 173.00 | 25 | 14.18 | 663 | 6 | 8 |
8 | 0.08 | 190 | 14.09 | 411 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 33 | 14.29 | 571 | 6 | 6 |
2 | 2004.00 | 4 | 11.40 | 348 | 6 | 6 |
3 | 2004.84 | 30 | 12.38 | 3290 | 6 | 6 |
4 | 1866.84 | 25 | 13.02 | 3035 | 6 | 7 |
5 | 1472.44 | 25 | 13.26 | 2487 | 6 | 9 |
6 | 848.88 | 25 | 13.66 | 1565 | 6 | 9 |
7 | 202.64 | 25 | 14.13 | 723 | 6 | 10 |
8 | 0.00 | 191 | 14.11 | 402 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 33 | 14.29 | 589 | 6 | 6 |
2 | 2002.80 | 4 | 11.49 | 366 | 6 | 6 |
3 | 2003.60 | 31 | 12.16 | 3480 | 6 | 6 |
4 | 1865.72 | 25 | 13.04 | 3022 | 6 | 6 |
5 | 1482.64 | 25 | 13.29 | 2513 | 6 | 8 |
6 | 877.36 | 25 | 13.64 | 1624 | 6 | 10 |
7 | 247.52 | 25 | 14.11 | 801 | 6 | 10 |
8 | 0.32 | 191 | 14.09 | 408 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.16 | 32 | 14.29 | 571 | 6 | 6 |
2 | 2004.96 | 4 | 11.49 | 366 | 6 | 6 |
3 | 2005.64 | 31 | 12.49 | 3388 | 6 | 6 |
4 | 1872.36 | 25 | 13.06 | 3038 | 6 | 7 |
5 | 1483.68 | 25 | 13.29 | 2429 | 6 | 9 |
6 | 1063.88 | 25 | 13.54 | 1835 | 6 | 10 |
7 | 172.16 | 25 | 14.18 | 637 | 6 | 9 |
8 | 0.00 | 191 | 14.12 | 402 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.68 | 33 | 14.29 | 553 | 6 | 6 |
2 | 977.56 | -1 | 14.29 | 553 | 6 | 6 |
3 | 2007.72 | 4 | 11.68 | 366 | 6 | 6 |
4 | 2008.36 | 31 | 12.62 | 3205 | 6 | 6 |
5 | 1857.48 | 25 | 13.03 | 3030 | 6 | 7 |
6 | 1452.60 | 25 | 13.29 | 2460 | 6 | 9 |
7 | 837.64 | 25 | 13.64 | 1604 | 6 | 10 |
8 | 187.20 | 25 | 14.18 | 694 | 6 | 10 |
9 | 0.56 | 191 | 14.13 | 401 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.36 | 34 | 14.36 | 553 | 6 | 6 |
2 | 967.64 | -1 | 14.36 | 553 | 6 | 6 |
3 | 2005.08 | 4 | 11.90 | 357 | 6 | 6 |
4 | 2005.72 | 31 | 12.58 | 3329 | 6 | 6 |
5 | 1857.76 | 25 | 13.08 | 2992 | 6 | 7 |
6 | 1463.64 | 25 | 13.31 | 2456 | 6 | 9 |
7 | 833.12 | 25 | 13.70 | 1570 | 6 | 9 |
8 | 104.52 | 25 | 14.24 | 583 | 6 | 9 |
9 | 52.76 | 25 | 14.28 | 506 | 6 | 10 |
10 | -0.24 | 191 | 14.08 | 403 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.80 | 32 | 14.29 | 571 | 6 | 6 |
2 | 1057.64 | 2 | 14.10 | 1964 | 6 | 7 |
3 | 2001.60 | 4 | 12.22 | 366 | 6 | 6 |
4 | 2002.48 | 31 | 12.90 | 3256 | 6 | 6 |
5 | 1852.36 | 25 | 13.11 | 2951 | 6 | 7 |
6 | 1453.88 | 25 | 13.34 | 2428 | 6 | 8 |
7 | 829.76 | 25 | 13.69 | 1572 | 6 | 10 |
8 | 171.52 | 25 | 14.21 | 669 | 6 | 10 |
9 | 1.24 | 191 | 14.11 | 409 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 33 | 14.29 | 589 | 6 | 6 |
2 | 962.36 | -1 | 14.29 | 589 | 6 | 6 |
3 | 2000.80 | 4 | 12.44 | 383 | 6 | 6 |
4 | 2001.64 | 31 | 12.80 | 3335 | 6 | 6 |
5 | 1859.32 | 25 | 13.10 | 2969 | 6 | 7 |
6 | 1667.48 | 25 | 13.22 | 2678 | 6 | 8 |
7 | 817.68 | 25 | 13.75 | 1458 | 6 | 9 |
8 | 164.64 | 25 | 14.23 | 640 | 6 | 9 |
9 | 0.32 | 191 | 14.14 | 400 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.24 | 30 | 14.36 | 589 | 6 | 6 |
2 | 1080.52 | 2 | 14.17 | 1982 | 6 | 8 |
3 | 2008.52 | 4 | 12.73 | 375 | 6 | 6 |
4 | 2009.20 | 31 | 12.96 | 3305 | 6 | 6 |
5 | 1849.52 | 25 | 13.10 | 2994 | 6 | 8 |
6 | 1452.72 | 25 | 13.33 | 2465 | 6 | 9 |
7 | 818.60 | 25 | 13.72 | 1549 | 6 | 9 |
8 | 93.56 | 25 | 14.31 | 565 | 6 | 9 |
9 | 0.40 | 191 | 14.11 | 411 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.64 | 31 | 14.36 | 553 | 6 | 6 |
2 | 972.12 | -1 | 14.36 | 553 | 6 | 6 |
3 | 2002.56 | 4 | 13.11 | 392 | 6 | 6 |
4 | 2003.20 | 31 | 13.00 | 3265 | 6 | 6 |
5 | 1845.84 | 25 | 13.09 | 2987 | 6 | 7 |
6 | 1446.36 | 25 | 13.31 | 2424 | 6 | 9 |
7 | 813.80 | 25 | 13.75 | 1522 | 6 | 9 |
8 | 180.68 | 25 | 14.21 | 692 | 6 | 10 |
9 | -0.12 | 191 | 14.13 | 410 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.60 | 32 | 14.36 | 553 | 6 | 6 |
2 | 978.16 | -1 | 14.36 | 553 | 6 | 6 |
3 | 1130.64 | 2 | 13.14 | 2035 | 6 | 6 |
4 | 2002.96 | 36 | 12.74 | 3214 | 6 | 7 |
5 | 1802.56 | 21 | 13.11 | 2912 | 6 | 8 |
6 | 1372.08 | 21 | 13.37 | 2333 | 6 | 8 |
7 | 709.32 | 21 | 13.81 | 1424 | 6 | 9 |
8 | 124.36 | 21 | 14.29 | 593 | 6 | 9 |
9 | 21.76 | 21 | 14.35 | 466 | 6 | 8 |
10 | 0.60 | 191 | 14.07 | 411 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.56 | 32 | 14.36 | 571 | 6 | 6 |
2 | 1108.64 | 2 | 13.27 | 1946 | 6 | 6 |
3 | 2002.12 | 36 | 12.83 | 3241 | 6 | 6 |
4 | 1805.80 | 21 | 13.10 | 2965 | 6 | 7 |
5 | 1371.56 | 21 | 13.38 | 2386 | 6 | 10 |
6 | 701.08 | 21 | 13.83 | 1386 | 6 | 10 |
7 | 243.92 | 21 | 14.18 | 791 | 6 | 11 |
8 | -0.12 | 191 | 14.14 | 405 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.88 | 32 | 14.36 | 589 | 6 | 6 |
2 | 1112.92 | 2 | 13.27 | 2017 | 6 | 6 |
3 | 2001.08 | 36 | 12.94 | 3209 | 6 | 6 |
4 | 1799.40 | 21 | 13.20 | 2916 | 6 | 8 |
5 | 1365.44 | 21 | 13.46 | 2233 | 6 | 8 |
6 | 700.12 | 21 | 13.88 | 1335 | 6 | 10 |
7 | 240.08 | 21 | 14.21 | 761 | 6 | 10 |
8 | 0.00 | 191 | 14.16 | 401 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.12 | 32 | 14.36 | 571 | 6 | 6 |
2 | 2002.48 | 36 | 13.13 | 3281 | 6 | 6 |
3 | 1837.88 | 20 | 13.28 | 3001 | 6 | 7 |
4 | 1622.36 | 20 | 13.39 | 2658 | 6 | 8 |
5 | 1165.56 | 20 | 13.66 | 1999 | 6 | 10 |
6 | 493.92 | 20 | 14.03 | 1122 | 6 | 10 |
7 | 50.80 | 20 | 14.38 | 499 | 6 | 9 |
8 | 3.68 | 20 | 14.35 | 434 | 6 | 8 |
9 | 0.12 | 191 | 14.09 | 409 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.00 | 32 | 14.42 | 571 | 6 | 6 |
2 | 2005.28 | 36 | 13.24 | 3243 | 6 | 6 |
3 | 1860.76 | 20 | 13.28 | 3004 | 6 | 7 |
4 | 1451.84 | 20 | 13.47 | 2477 | 6 | 8 |
5 | 1010.68 | 21 | 13.73 | 1809 | 6 | 9 |
6 | 553.44 | 21 | 14.01 | 1190 | 6 | 9 |
7 | 59.64 | 21 | 14.38 | 525 | 6 | 8 |
8 | 0.12 | 191 | 14.15 | 409 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.52 | 32 | 14.42 | 571 | 6 | 6 |
2 | 2008.52 | 36 | 12.95 | 3311 | 6 | 6 |
3 | 1828.64 | 20 | 13.31 | 2984 | 6 | 7 |
4 | 1621.08 | 20 | 13.40 | 2731 | 6 | 9 |
5 | 969.00 | 21 | 13.75 | 1763 | 6 | 10 |
6 | 537.44 | 21 | 14.01 | 1212 | 6 | 9 |
7 | 48.40 | 21 | 14.38 | 507 | 6 | 9 |
8 | 0.08 | 190 | 14.11 | 414 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.00 | 34 | 14.42 | 553 | 6 | 6 |
2 | 938.64 | -2 | 14.42 | 553 | 6 | 6 |
3 | 1018.48 | 1 | 13.72 | 1910 | 6 | 6 |
4 | 2008.56 | 36 | 13.22 | 3254 | 6 | 7 |
5 | 1851.84 | 20 | 13.27 | 2986 | 6 | 8 |
6 | 1635.76 | 20 | 13.46 | 2669 | 6 | 8 |
7 | 1183.16 | 21 | 13.70 | 1949 | 6 | 10 |
8 | 498.72 | 21 | 14.08 | 1108 | 6 | 10 |
9 | 49.80 | 21 | 14.38 | 507 | 6 | 9 |
10 | 0.12 | 191 | 14.12 | 412 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.88 | 34 | 14.48 | 553 | 6 | 6 |
2 | 2001.68 | 36 | 13.19 | 3247 | 6 | 6 |
3 | 1831.24 | 20 | 13.35 | 2935 | 6 | 7 |
4 | 1620.68 | 20 | 13.47 | 2678 | 6 | 8 |
5 | 1175.32 | 21 | 13.66 | 2033 | 6 | 9 |
6 | 497.08 | 21 | 14.09 | 1128 | 6 | 9 |
7 | 49.12 | 21 | 14.45 | 478 | 6 | 9 |
8 | 0.36 | 201 | 14.15 | 401 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.08 | 32 | 14.48 | 553 | 6 | 6 |
2 | 1043.32 | 1 | 14.29 | 1946 | 6 | 6 |
3 | 1029.08 | 1 | 14.17 | 1910 | 6 | 6 |
4 | 2004.96 | 36 | 13.06 | 3287 | 6 | 6 |
5 | 1836.88 | 20 | 13.35 | 2973 | 6 | 8 |
6 | 1629.04 | 21 | 13.44 | 2664 | 6 | 8 |
7 | 976.44 | 21 | 13.82 | 1731 | 6 | 10 |
8 | 326.36 | 21 | 14.26 | 900 | 6 | 9 |
9 | 20.36 | 21 | 14.48 | 434 | 6 | 8 |
10 | -0.20 | 201 | 14.19 | 393 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.48 | 33 | 14.36 | 589 | 6 | 6 |
2 | 957.40 | -1 | 14.36 | 589 | 6 | 6 |
3 | 2009.60 | 36 | 13.34 | 3187 | 6 | 7 |
4 | 1844.48 | 20 | 13.37 | 2968 | 6 | 8 |
5 | 1438.36 | 21 | 13.49 | 2513 | 6 | 8 |
6 | 1023.36 | 21 | 13.76 | 1864 | 6 | 11 |
7 | 557.76 | 21 | 14.07 | 1267 | 6 | 10 |
8 | 0.16 | 201 | 14.24 | 402 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.76 | 31 | 14.42 | 553 | 6 | 6 |
2 | 1057.68 | 1 | 14.36 | 2000 | 6 | 7 |
3 | 1026.68 | 1 | 14.29 | 1892 | 6 | 6 |
4 | 2008.76 | 36 | 13.23 | 3245 | 6 | 7 |
5 | 1831.60 | 20 | 13.34 | 3053 | 6 | 8 |
6 | 1422.24 | 21 | 13.57 | 2384 | 6 | 8 |
7 | 975.08 | 21 | 13.80 | 1777 | 6 | 10 |
8 | 516.72 | 21 | 14.08 | 1180 | 6 | 10 |
9 | 39.40 | 21 | 14.45 | 493 | 6 | 8 |
10 | 0.08 | 201 | 14.14 | 408 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.92 | 33 | 14.29 | 607 | 6 | 6 |
2 | 970.56 | -1 | 14.29 | 607 | 6 | 6 |
3 | 2007.28 | 36 | 13.27 | 3241 | 6 | 6 |
4 | 1833.68 | 21 | 13.36 | 2959 | 6 | 7 |
5 | 1619.64 | 21 | 13.48 | 2632 | 6 | 8 |
6 | 1152.48 | 21 | 13.75 | 1967 | 6 | 10 |
7 | 432.80 | 21 | 14.17 | 993 | 6 | 9 |
8 | 35.68 | 21 | 14.45 | 466 | 6 | 8 |
9 | -0.04 | 201 | 14.15 | 399 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.00 | 34 | 14.42 | 571 | 6 | 6 |
2 | 967.72 | -1 | 14.42 | 571 | 6 | 6 |
3 | 2008.88 | 36 | 13.01 | 3239 | 6 | 7 |
4 | 1838.08 | 21 | 13.34 | 3029 | 6 | 8 |
5 | 1621.36 | 21 | 13.45 | 2680 | 6 | 10 |
6 | 1146.40 | 21 | 13.73 | 1964 | 6 | 10 |
7 | 428.16 | 21 | 14.18 | 974 | 6 | 9 |
8 | 32.08 | 21 | 14.46 | 468 | 6 | 9 |
9 | 0.20 | 201 | 14.12 | 408 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.44 | 34 | 14.36 | 571 | 6 | 6 |
2 | 1027.88 | 1 | 14.36 | 1964 | 6 | 6 |
3 | 2001.52 | 36 | 13.19 | 3281 | 6 | 7 |
4 | 1821.88 | 21 | 13.37 | 2936 | 6 | 8 |
5 | 1614.72 | 21 | 13.49 | 2676 | 6 | 8 |
6 | 923.60 | 21 | 13.87 | 1676 | 6 | 10 |
7 | 466.24 | 21 | 14.14 | 1077 | 6 | 9 |
8 | 0.00 | 201 | 14.16 | 418 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.20 | 33 | 14.42 | 571 | 6 | 6 |
2 | 1802.36 | 36 | 13.03 | 3096 | 6 | 7 |
3 | 1669.32 | 21 | 13.45 | 2707 | 6 | 8 |
4 | 1482.20 | 21 | 13.55 | 2481 | 6 | 8 |
5 | 854.24 | 21 | 13.90 | 1589 | 6 | 10 |
6 | 634.64 | 21 | 14.06 | 1267 | 6 | 9 |
7 | 0.48 | 200 | 14.19 | 413 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.72 | 33 | 14.42 | 571 | 6 | 6 |
2 | 2001.40 | 36 | 13.27 | 3231 | 6 | 7 |
3 | 1832.76 | 21 | 13.39 | 2914 | 6 | 8 |
4 | 1619.40 | 21 | 13.50 | 2596 | 6 | 9 |
5 | 1154.24 | 21 | 13.76 | 1969 | 6 | 10 |
6 | 452.08 | 21 | 14.20 | 1069 | 6 | 10 |
7 | 0.20 | 201 | 14.20 | 419 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.88 | 33 | 14.42 | 571 | 6 | 6 |
2 | 1629.76 | 36 | 13.50 | 2741 | 6 | 7 |
3 | 1519.64 | 21 | 13.57 | 2459 | 6 | 8 |
4 | 1325.20 | 21 | 13.69 | 2172 | 6 | 9 |
5 | 877.40 | 21 | 13.94 | 1583 | 6 | 10 |
6 | 192.64 | 21 | 14.39 | 700 | 6 | 10 |
7 | -0.36 | 200 | 14.23 | 400 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.20 | 33 | 14.48 | 535 | 6 | 6 |
2 | 1745.12 | 36 | 13.42 | 2852 | 6 | 7 |
3 | 1662.84 | 21 | 13.49 | 2674 | 6 | 8 |
4 | 1472.16 | 21 | 13.58 | 2434 | 6 | 8 |
5 | 1042.16 | 21 | 13.86 | 1836 | 6 | 10 |
6 | 331.76 | 21 | 14.30 | 892 | 6 | 10 |
7 | 0.36 | 201 | 14.23 | 392 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.52 | 34 | 14.42 | 571 | 6 | 6 |
2 | 953.64 | -1 | 14.42 | 571 | 6 | 6 |
3 | 2008.36 | 36 | 13.31 | 3195 | 6 | 6 |
4 | 1846.60 | 21 | 13.40 | 2940 | 6 | 7 |
5 | 1627.12 | 21 | 13.55 | 2608 | 6 | 8 |
6 | 934.04 | 21 | 13.93 | 1626 | 6 | 11 |
7 | 487.92 | 21 | 14.19 | 1107 | 6 | 10 |
8 | 29.68 | 21 | 14.55 | 460 | 6 | 8 |
9 | -0.04 | 201 | 14.19 | 406 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 34 | 14.48 | 553 | 6 | 6 |
2 | 2005.16 | 36 | 13.24 | 3252 | 6 | 6 |
3 | 1856.52 | 21 | 13.34 | 3108 | 6 | 9 |
4 | 1638.92 | 21 | 13.46 | 2721 | 6 | 8 |
5 | 1181.56 | 21 | 13.76 | 2076 | 6 | 10 |
6 | 461.88 | 21 | 14.20 | 1128 | 6 | 10 |
7 | 0.20 | 201 | 14.21 | 422 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.64 | 34 | 14.36 | 589 | 6 | 6 |
2 | 2008.84 | 36 | 13.07 | 3329 | 6 | 6 |
3 | 1857.36 | 21 | 13.39 | 3019 | 6 | 7 |
4 | 1652.68 | 21 | 13.50 | 2739 | 6 | 8 |
5 | 992.80 | 21 | 13.87 | 1819 | 6 | 12 |
6 | 299.44 | 21 | 14.36 | 878 | 6 | 9 |
7 | 0.04 | 201 | 14.25 | 402 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.12 | 34 | 14.48 | 535 | 6 | 6 |
2 | 2004.68 | 36 | 12.99 | 3364 | 6 | 7 |
3 | 1839.12 | 21 | 13.42 | 2910 | 6 | 7 |
4 | 1623.24 | 21 | 13.54 | 2608 | 6 | 8 |
5 | 1409.48 | 21 | 13.67 | 2315 | 6 | 9 |
6 | 447.56 | 21 | 14.26 | 1059 | 6 | 10 |
7 | 0.00 | 201 | 14.24 | 395 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.48 | 33 | 14.48 | 553 | 6 | 6 |
2 | 1038.68 | 1 | 14.61 | 1946 | 6 | 6 |
3 | 2005.56 | 36 | 13.38 | 3267 | 6 | 7 |
4 | 1854.28 | 21 | 13.44 | 2934 | 6 | 7 |
5 | 1446.76 | 21 | 13.67 | 2324 | 6 | 8 |
6 | 1013.60 | 21 | 13.91 | 1749 | 6 | 10 |
7 | 327.48 | 21 | 14.37 | 835 | 6 | 10 |
8 | 0.24 | 201 | 14.31 | 353 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.44 | 34 | 14.42 | 553 | 6 | 6 |
2 | 956.36 | -1 | 14.42 | 553 | 6 | 6 |
3 | 2008.36 | 36 | 13.35 | 3273 | 6 | 7 |
4 | 1858.28 | 21 | 13.40 | 3023 | 6 | 8 |
5 | 1659.64 | 21 | 13.48 | 2737 | 6 | 8 |
6 | 1168.40 | 21 | 13.79 | 2039 | 6 | 10 |
7 | 456.04 | 21 | 14.26 | 1075 | 6 | 9 |
8 | -0.20 | 201 | 14.24 | 402 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.08 | 32 | 14.42 | 553 | 6 | 6 |
2 | 1071.00 | 2 | 14.61 | 2000 | 6 | 7 |
3 | 1023.68 | 1 | 14.55 | 1910 | 6 | 6 |
4 | 2011.12 | 36 | 13.31 | 3250 | 6 | 6 |
5 | 1860.92 | 21 | 13.39 | 2997 | 6 | 8 |
6 | 1431.40 | 21 | 13.67 | 2336 | 6 | 9 |
7 | 1003.16 | 21 | 13.92 | 1745 | 6 | 10 |
8 | 312.60 | 21 | 14.37 | 839 | 6 | 10 |
9 | 0.24 | 201 | 14.26 | 380 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.28 | 39 | 14.36 | 571 | 6 | 6 |
2 | 795.04 | -4 | 14.36 | 571 | 6 | 6 |
3 | 924.40 | -1 | 14.36 | 571 | 6 | 6 |
4 | 2008.08 | 35 | 13.10 | 3264 | 6 | 7 |
5 | 1849.20 | 20 | 13.43 | 2963 | 6 | 8 |
6 | 1458.88 | 21 | 13.61 | 2449 | 6 | 9 |
7 | 1027.68 | 20 | 13.92 | 1838 | 6 | 9 |
8 | 352.04 | 20 | 14.35 | 957 | 6 | 10 |
9 | 5.56 | 20 | 14.62 | 441 | 6 | 10 |
10 | 0.08 | 201 | 14.19 | 408 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 40 | 14.36 | 571 | 6 | 6 |
2 | 887.88 | 36 | 14.10 | 1660 | 6 | 6 |
3 | 977.12 | 21 | 13.95 | 1835 | 6 | 7 |
4 | 818.56 | 21 | 14.03 | 1608 | 6 | 9 |
5 | 605.36 | 21 | 14.17 | 1301 | 6 | 9 |
6 | 0.40 | 201 | 14.28 | 384 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.92 | 39 | 14.36 | 571 | 6 | 6 |
2 | 869.24 | 36 | 14.11 | 1640 | 6 | 7 |
3 | 930.44 | 21 | 13.97 | 1761 | 6 | 7 |
4 | 768.00 | 21 | 14.07 | 1519 | 6 | 9 |
5 | 560.12 | 21 | 14.23 | 1213 | 6 | 9 |
6 | -0.04 | 201 | 14.30 | 380 | 6 | 39 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.28 | 39 | 14.42 | 517 | 6 | 6 |
2 | 849.32 | 36 | 14.12 | 1614 | 6 | 6 |
3 | 920.16 | 21 | 13.96 | 1743 | 6 | 7 |
4 | 776.48 | 21 | 14.06 | 1531 | 6 | 10 |
5 | 176.80 | 21 | 14.49 | 666 | 6 | 8 |
6 | -0.04 | 201 | 14.27 | 390 | 6 | 36 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.56 | 41 | 14.42 | 500 | 6 | 6 |
2 | 708.72 | -1 | 14.42 | 500 | 6 | 6 |
3 | 883.64 | 36 | 14.11 | 1637 | 6 | 7 |
4 | 938.00 | 21 | 13.97 | 1733 | 6 | 8 |
5 | 791.52 | 21 | 14.07 | 1515 | 6 | 9 |
6 | 356.80 | 21 | 14.39 | 882 | 6 | 9 |
7 | 0.40 | 201 | 14.34 | 347 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.64 | 33 | 14.48 | 517 | 6 | 6 |
2 | 789.80 | 6 | 14.68 | 1535 | 6 | 7 |
3 | 800.36 | 1 | 14.74 | 1553 | 6 | 7 |
4 | 897.20 | 36 | 14.11 | 1656 | 6 | 6 |
5 | 964.36 | 21 | 13.98 | 1753 | 6 | 7 |
6 | 800.80 | 21 | 14.08 | 1523 | 6 | 9 |
7 | 360.28 | 21 | 14.40 | 884 | 6 | 9 |
8 | 0.16 | 200 | 14.34 | 346 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.64 | 33 | 14.55 | 500 | 6 | 6 |
2 | 1143.32 | 36 | 13.89 | 2025 | 6 | 7 |
3 | 1128.64 | 21 | 13.82 | 1989 | 6 | 9 |
4 | 951.12 | 21 | 13.95 | 1697 | 6 | 9 |
5 | 310.92 | 21 | 14.43 | 807 | 6 | 9 |
6 | -0.28 | 201 | 14.34 | 343 | 6 | 33 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.12 | 33 | 14.55 | 517 | 6 | 6 |
2 | 1190.12 | 36 | 13.89 | 2036 | 6 | 7 |
3 | 1157.64 | 21 | 13.82 | 1969 | 6 | 10 |
4 | 989.72 | 21 | 13.93 | 1757 | 6 | 11 |
5 | 579.60 | 21 | 14.20 | 1215 | 6 | 10 |
6 | 63.20 | 21 | 14.63 | 452 | 6 | 9 |
7 | 0.24 | 200 | 14.31 | 348 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.60 | 33 | 14.48 | 517 | 6 | 6 |
2 | 1173.76 | 36 | 13.90 | 2040 | 6 | 7 |
3 | 1132.04 | 21 | 13.81 | 1981 | 6 | 9 |
4 | 976.80 | 21 | 13.93 | 1729 | 6 | 10 |
5 | 763.00 | 21 | 14.07 | 1452 | 6 | 10 |
6 | 131.16 | 21 | 14.59 | 551 | 6 | 9 |
7 | 0.32 | 200 | 14.32 | 346 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.20 | 33 | 14.55 | 517 | 6 | 6 |
2 | 1177.56 | 36 | 13.93 | 1996 | 6 | 8 |
3 | 1154.96 | 21 | 13.82 | 1989 | 6 | 11 |
4 | 999.64 | 21 | 13.92 | 1773 | 6 | 10 |
5 | 786.32 | 21 | 14.07 | 1477 | 6 | 10 |
6 | 117.40 | 21 | 14.59 | 525 | 6 | 9 |
7 | 0.00 | 201 | 14.32 | 349 | 6 | 35 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 32 | 14.55 | 535 | 6 | 6 |
2 | 1031.72 | 1 | 14.55 | 1910 | 6 | 6 |
3 | 1173.72 | 36 | 13.93 | 1984 | 6 | 8 |
4 | 1148.16 | 21 | 13.85 | 1930 | 6 | 9 |
5 | 985.92 | 21 | 13.95 | 1725 | 6 | 9 |
6 | 562.64 | 21 | 14.23 | 1164 | 6 | 10 |
7 | 134.60 | 21 | 14.59 | 551 | 6 | 10 |
8 | 0.00 | 201 | 14.33 | 346 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.88 | 32 | 14.55 | 500 | 6 | 6 |
2 | 1184.04 | 36 | 13.92 | 2019 | 6 | 7 |
3 | 1176.52 | 21 | 13.83 | 2017 | 6 | 10 |
4 | 1017.12 | 21 | 13.93 | 1789 | 6 | 10 |
5 | 577.36 | 21 | 14.21 | 1206 | 6 | 10 |
6 | 0.16 | 200 | 14.35 | 351 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 32 | 14.55 | 535 | 6 | 6 |
2 | 1075.88 | 36 | 14.01 | 1901 | 6 | 8 |
3 | 1077.24 | 21 | 13.90 | 1902 | 6 | 8 |
4 | 922.92 | 21 | 13.98 | 1676 | 6 | 9 |
5 | 520.84 | 21 | 14.27 | 1124 | 6 | 9 |
6 | -0.04 | 200 | 14.37 | 349 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.92 | 32 | 14.55 | 517 | 6 | 6 |
2 | 1055.40 | 36 | 14.06 | 1843 | 6 | 7 |
3 | 1054.28 | 21 | 13.92 | 1834 | 6 | 9 |
4 | 913.76 | 21 | 13.98 | 1662 | 6 | 10 |
5 | 293.20 | 21 | 14.47 | 787 | 6 | 9 |
6 | 44.32 | 21 | 14.68 | 418 | 6 | 9 |
7 | 20.16 | 21 | 14.62 | 378 | 6 | 11 |
8 | 0.08 | 201 | 14.31 | 345 | 6 | 44 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 32 | 14.61 | 517 | 6 | 6 |
2 | 2008.80 | 36 | 13.47 | 3179 | 6 | 9 |
3 | 1846.24 | 21 | 13.45 | 2964 | 6 | 7 |
4 | 1421.96 | 21 | 13.69 | 2324 | 6 | 9 |
5 | 973.92 | 21 | 13.97 | 1698 | 6 | 10 |
6 | 514.84 | 21 | 14.29 | 1107 | 6 | 10 |
7 | 0.08 | 201 | 14.37 | 347 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.56 | 32 | 14.61 | 517 | 6 | 6 |
2 | 1022.04 | 1 | 14.61 | 1928 | 6 | 6 |
3 | 2003.80 | 36 | 13.45 | 3142 | 6 | 7 |
4 | 1830.16 | 21 | 13.49 | 2908 | 6 | 8 |
5 | 1430.20 | 21 | 13.69 | 2311 | 6 | 9 |
6 | 983.56 | 21 | 13.95 | 1729 | 6 | 10 |
7 | 145.00 | 21 | 14.62 | 573 | 6 | 9 |
8 | 0.28 | 201 | 14.37 | 347 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.44 | 31 | 14.55 | 517 | 6 | 6 |
2 | 2016.20 | 70 | 13.13 | 3177 | 6 | 8 |
3 | 1318.00 | 25 | 13.75 | 2138 | 6 | 10 |
4 | 605.04 | 25 | 14.21 | 1221 | 6 | 10 |
5 | 25.96 | 25 | 14.75 | 386 | 6 | 9 |
6 | -0.12 | 251 | 14.32 | 340 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.32 | 31 | 14.61 | 535 | 6 | 6 |
2 | 2006.88 | 70 | 13.13 | 3129 | 6 | 7 |
3 | 1519.80 | 25 | 13.63 | 2474 | 6 | 9 |
4 | 386.64 | 25 | 14.39 | 931 | 6 | 10 |
5 | 0.12 | 250 | 14.33 | 348 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.92 | 31 | 14.61 | 517 | 6 | 6 |
2 | 2009.60 | 70 | 13.15 | 3150 | 6 | 8 |
3 | 1285.52 | 25 | 13.75 | 2131 | 6 | 10 |
4 | 341.36 | 25 | 14.44 | 857 | 6 | 10 |
5 | 6.92 | 25 | 14.78 | 360 | 6 | 9 |
6 | 0.12 | 251 | 14.31 | 340 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 31 | 14.61 | 517 | 6 | 6 |
2 | 2000.92 | 70 | 13.15 | 3132 | 6 | 9 |
3 | 1286.52 | 25 | 13.76 | 2087 | 6 | 8 |
4 | 593.16 | 25 | 14.23 | 1212 | 6 | 10 |
5 | 0.16 | 251 | 14.35 | 348 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.44 | 30 | 14.61 | 517 | 6 | 6 |
2 | 2001.00 | 70 | 13.08 | 3144 | 6 | 10 |
3 | 1280.52 | 25 | 13.76 | 2096 | 6 | 9 |
4 | 806.28 | 25 | 14.08 | 1471 | 6 | 10 |
5 | 48.56 | 25 | 14.74 | 424 | 6 | 9 |
6 | 25.08 | 25 | 14.65 | 383 | 6 | 11 |
7 | 0.16 | 251 | 14.29 | 339 | 6 | 37 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.12 | 29 | 14.68 | 517 | 6 | 6 |
2 | 1048.52 | 1 | 14.80 | 1928 | 6 | 7 |
3 | 2031.24 | 70 | 13.12 | 3172 | 6 | 8 |
4 | 1133.64 | 25 | 13.85 | 1881 | 6 | 9 |
5 | 441.32 | 25 | 14.39 | 982 | 6 | 10 |
6 | 0.12 | 251 | 14.36 | 345 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 29 | 14.61 | 535 | 6 | 6 |
2 | 2008.52 | 70 | 13.07 | 3195 | 6 | 7 |
3 | 1250.12 | 25 | 13.77 | 2083 | 6 | 9 |
4 | 559.40 | 25 | 14.28 | 1161 | 6 | 10 |
5 | 0.12 | 250 | 14.35 | 349 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.72 | 29 | 14.61 | 517 | 6 | 6 |
2 | 1295.92 | 70 | 13.51 | 2203 | 6 | 10 |
3 | 1077.52 | 25 | 13.90 | 1878 | 6 | 10 |
4 | 30.08 | 25 | 14.76 | 406 | 6 | 8 |
5 | -0.12 | 251 | 14.28 | 348 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.48 | 27 | 14.68 | 517 | 6 | 6 |
2 | 1051.40 | 1 | 14.80 | 1928 | 6 | 7 |
3 | 1220.96 | 70 | 13.56 | 2077 | 6 | 9 |
4 | 791.12 | 25 | 14.08 | 1524 | 6 | 11 |
5 | 135.44 | 25 | 14.66 | 565 | 6 | 9 |
6 | 0.12 | 250 | 14.30 | 350 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.00 | 29 | 14.61 | 517 | 6 | 6 |
2 | 1504.48 | 70 | 13.37 | 2529 | 6 | 8 |
3 | 832.08 | 25 | 14.02 | 1572 | 6 | 9 |
4 | 67.12 | 25 | 14.72 | 460 | 6 | 7 |
5 | 0.16 | 251 | 14.27 | 350 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.04 | 28 | 14.61 | 553 | 6 | 6 |
2 | 1506.00 | 70 | 13.32 | 2534 | 6 | 8 |
3 | 810.88 | 25 | 13.99 | 1558 | 6 | 11 |
4 | 59.84 | 25 | 14.71 | 455 | 6 | 9 |
5 | 0.72 | 251 | 14.26 | 349 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.00 | 27 | 14.55 | 553 | 6 | 6 |
2 | 1043.84 | 1 | 14.61 | 1982 | 6 | 6 |
3 | 1501.52 | 70 | 13.27 | 2530 | 6 | 8 |
4 | 809.12 | 25 | 13.93 | 1572 | 6 | 12 |
5 | 55.92 | 25 | 14.67 | 453 | 6 | 8 |
6 | 0.00 | 251 | 14.22 | 357 | 6 | 41 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.72 | 27 | 14.74 | 553 | 6 | 6 |
2 | 1012.52 | 70 | 13.56 | 1871 | 6 | 9 |
3 | 7.64 | 25 | 14.64 | 397 | 6 | 11 |
4 | -0.08 | 251 | 14.17 | 363 | 6 | 31 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 53.56 | 70 | 14.82 | 433 | 159 | 7 |
2 | 13.00 | 25 | 14.70 | 374 | 6 | 7 |
3 | 0.24 | 250 | 14.34 | 329 | 6 | 40 |