SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8247 WMO= 5904531


Cycle 232 GMT 5/ 6/2019 12:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.44 36 10.50 464 6 6
2 1159.08 120 10.29 333 6 6
3 1167.96 101 6.98 1992 6 6
4 1169.24 100 6.88 1988 6 6
5 111.36 45 10.22 476 6 6
6 67.16 45 10.42 403 6 6
7 0.08 181 10.68 303 6 8

Cycle 231 GMT 26/ 5/2019 17:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.24 36 10.63 464 6 6
2 1010.68 99 7.51 1766 6 6
3 298.24 44 9.62 750 6 6
4 63.56 44 10.50 375 6 6
5 0.00 181 10.72 296 6 9

Cycle 230 GMT 16/ 5/2019 23:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 37 10.57 464 6 6
2 1905.88 120 10.47 358 6 6
3 1909.52 101 5.54 3195 6 6
4 1908.36 99 5.05 3259 6 6
5 1788.12 45 5.67 2907 6 6
6 1667.00 44 5.92 2750 6 6
7 1487.48 44 6.43 2431 6 6
8 1127.92 44 7.23 1967 6 6
9 702.84 45 8.39 1381 6 6
10 121.52 45 10.30 497 6 6
11 34.76 45 10.62 356 6 6
12 0.08 181 10.72 307 6 9

Cycle 229 GMT 16/ 5/2019 2:37: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.40 36 10.75 428 6 6
2 1185.96 120 10.41 332 6 6
3 1195.04 101 7.57 2043 6 6
4 1194.84 100 7.62 2032 6 6
5 85.12 44 10.50 433 6 6
6 44.44 44 10.65 362 6 6
7 0.04 181 10.80 295 6 9

Cycle 228 GMT 6/ 5/2019 7:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.92 36 10.69 446 6 6
2 1003.76 99 8.07 1762 6 6
3 245.76 45 10.11 676 6 6
4 49.60 44 10.67 373 6 6
5 0.04 181 10.83 298 6 8

Cycle 227 GMT 26/ 4/2019 13:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.92 37 10.69 464 6 6
2 1900.32 120 10.56 368 6 6
3 1905.44 101 6.48 3077 6 6
4 1903.52 99 6.23 3094 6 6
5 1001.00 44 8.15 1803 6 6
6 342.00 45 9.82 850 6 6
7 81.60 45 10.58 429 6 6
8 0.20 181 10.87 296 6 9

Cycle 226 GMT 25/ 4/2019 17:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.00 35 10.75 446 6 6
2 1034.64 1 8.69 1857 6 6
3 1182.40 120 10.44 339 6 6
4 1193.12 101 8.00 2036 6 6
5 1194.52 99 8.07 2031 6 6
6 126.16 44 10.45 504 6 6
7 21.32 44 10.79 329 6 6
8 -0.04 181 10.85 303 6 11

Cycle 225 GMT 15/ 4/2019 23: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.36 36 10.82 446 6 6
2 1004.20 99 8.44 1771 6 6
3 146.40 44 10.46 528 6 6
4 48.28 44 10.78 365 6 6
5 0.08 181 10.89 301 6 10

Cycle 224 GMT 6/ 4/2019 4:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.04 37 10.75 464 6 6
2 1900.12 120 10.66 357 6 6
3 1904.28 101 7.06 3054 6 6
4 1900.32 99 6.81 3066 6 6
5 919.24 44 8.65 1698 6 6
6 216.88 45 10.32 646 6 6
7 53.52 45 10.74 376 6 6
8 0.00 181 10.88 303 6 10

Cycle 223 GMT 5/ 4/2019 8:41: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.20 35 10.75 446 6 6
2 1147.32 120 10.53 335 6 6
3 1156.56 101 8.32 2010 6 6
4 1156.44 99 8.44 1993 6 6
5 65.52 44 10.72 395 6 6
6 0.08 181 10.89 301 6 9

Cycle 222 GMT 26/ 3/2019 14:13: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.24 34 10.82 446 6 6
2 1052.04 1 8.57 1946 6 6
3 1031.40 1 8.88 1857 6 6
4 1042.76 99 8.58 1827 6 6
5 135.04 45 10.59 493 6 6
6 34.12 44 10.87 331 6 6
7 0.04 181 10.93 289 6 12

Cycle 221 GMT 16/ 3/2019 20: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 33 10.82 464 6 6
2 1086.68 2 8.69 1946 6 6
3 1049.12 1 8.88 1875 6 6
4 1913.04 120 10.66 362 6 6
5 1919.20 101 7.28 3101 6 6
6 1916.44 99 7.08 3087 6 6
7 891.92 44 8.89 1658 6 6
8 107.52 45 10.65 474 6 6
9 28.36 45 10.85 335 6 6
10 0.00 181 10.92 296 6 10

Cycle 220 GMT 16/ 3/2019 0:14: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.24 38 10.82 446 6 6
2 940.32 -1 10.82 446 6 6
3 1176.12 120 10.56 339 6 6
4 1186.64 101 8.45 2065 6 6
5 1186.36 99 8.51 2050 6 6
6 58.56 44 10.76 387 6 6
7 0.12 181 10.93 298 6 9

Cycle 219 GMT 6/ 3/2019 5:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.16 36 10.82 446 6 6
2 927.76 -1 10.82 446 6 6
3 1019.76 99 8.79 1803 6 6
4 129.80 44 10.63 511 6 6
5 30.68 44 10.86 340 6 6
6 -0.04 180 10.92 298 6 14

Cycle 218 GMT 24/ 2/2019 11:48: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.16 38 10.82 446 6 6
2 928.72 -1 10.82 446 6 6
3 924.68 -1 10.82 446 6 6
4 1629.32 120 10.68 356 6 6
5 1629.04 101 7.90 2679 6 6
6 1624.52 99 7.73 2656 6 6
7 544.44 44 9.71 1150 6 6
8 125.88 44 10.64 492 6 6
9 0.12 181 10.93 297 6 13

Cycle 217 GMT 23/ 2/2019 15:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 38 10.88 446 6 6
2 1167.04 120 10.64 333 6 6
3 1181.80 101 8.65 2046 6 6
4 1184.44 99 8.61 2034 6 6
5 47.32 44 10.78 373 6 6
6 0.04 181 10.92 293 6 11

Cycle 216 GMT 13/ 2/2019 21:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.44 33 10.82 446 6 6
2 1040.56 3 9.13 1821 6 6
3 1008.64 99 8.88 1790 6 6
4 125.36 44 10.69 473 6 6
5 0.12 181 10.96 283 6 8

Cycle 215 GMT 4/ 2/2019 3:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 30 10.82 446 6 6
2 1024.32 4 9.00 1875 6 6
3 1055.32 3 8.82 1928 6 6
4 1040.12 1 9.19 1857 6 6
5 1020.92 1 9.00 1839 6 6
6 1902.64 120 10.65 356 6 6
7 1908.00 101 7.36 3065 6 6
8 1904.52 99 6.13 3128 6 6
9 802.36 45 9.17 1527 6 6
10 188.28 45 10.48 600 6 6
11 50.92 45 10.83 370 6 6
12 0.04 181 10.93 298 6 9

Cycle 214 GMT 3/ 2/2019 6:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.84 29 11.25 446 6 6
2 1034.36 3 9.63 1857 6 6
3 1086.76 5 9.63 1928 6 6
4 1164.40 120 10.95 330 6 6
5 1174.64 101 7.77 1986 6 6
6 1175.76 99 7.96 2007 6 6
7 88.80 44 10.74 431 6 6
8 0.08 181 10.93 295 6 8

Cycle 213 GMT 24/ 1/2019 12: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.36 25 11.75 446 6 6
2 1042.16 6 10.32 1875 6 6
3 1060.08 2 10.19 1946 6 6
4 1030.88 1 10.32 1875 6 6
5 1022.44 99 9.11 1807 6 6
6 143.16 44 11.02 496 6 6
7 29.72 44 11.27 306 6 6
8 0.00 180 11.21 296 6 11

Cycle 212 GMT 14/ 1/2019 18: 3: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.52 27 12.75 464 6 6
2 1104.32 3 11.19 2000 6 6
3 1043.00 1 11.19 1910 6 6
4 1695.12 120 12.41 384 6 6
5 1695.08 101 7.64 2772 6 6
6 1690.44 99 5.48 2737 6 6
7 1270.52 45 9.24 2204 6 6
8 329.28 45 10.94 840 6 6
9 66.04 45 11.54 415 6 6
10 -0.04 180 11.58 307 6 11

Cycle 211 GMT 13/ 1/2019 21:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.80 24 13.37 482 6 6
2 1080.24 4 11.38 1964 6 6
3 1049.92 1 11.13 1928 6 6
4 1021.64 1 10.38 1946 6 6
5 1168.80 120 11.45 342 6 6
6 1182.60 101 4.64 1495 6 7
7 1195.80 99 4.97 1780 7 7
8 1217.20 45 8.54 2068 6 6
9 1087.08 45 9.04 1921 6 6
10 918.00 45 9.59 1704 6 6
11 97.56 45 12.04 467 6 6
12 0.04 180 12.24 302 6 8

Cycle 210 GMT 4/ 1/2019 1: 3: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.64 27 13.75 482 6 6
2 947.32 -1 13.75 482 6 6
3 1002.04 99 7.83 1765 6 6
4 177.64 44 12.58 592 6 6
5 36.36 44 13.09 371 6 7
6 0.08 181 12.96 325 6 15

Cycle 209 GMT 25/12/2018 6:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 27 14.00 482 6 6
2 1904.44 120 13.03 391 6 6
3 1909.20 101 8.09 3083 6 6
4 1904.64 99 8.07 3095 6 6
5 306.08 45 12.86 830 6 6
6 51.64 44 13.68 408 6 7
7 -0.08 181 13.43 325 6 19

Cycle 208 GMT 24/12/2018 10:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.08 29 14.00 482 6 6
2 895.44 -1 14.00 482 6 6
3 932.84 -1 14.00 482 6 6
4 1182.96 120 12.05 363 6 6
5 1194.08 101 5.76 2016 6 6
6 1201.68 99 7.19 2054 6 6
7 524.36 45 12.24 1167 6 6
8 52.84 45 13.81 412 6 7
9 0.04 181 13.58 327 6 14

Cycle 207 GMT 14/12/2018 15:51: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.52 27 14.25 464 6 6
2 971.68 99 8.82 1731 6 6
3 117.48 44 13.67 529 6 7
4 18.56 44 14.07 360 6 7
5 0.00 181 13.72 336 6 21

Cycle 206 GMT 4/12/2018 21:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.36 24 14.12 482 6 6
2 1080.88 2 11.44 1964 6 6
3 1021.40 1 10.94 1875 6 6
4 1901.00 120 13.14 395 6 6
5 1907.08 101 8.61 3092 6 6
6 1902.60 99 8.62 3077 6 6
7 164.08 45 13.64 617 6 7
8 0.04 181 13.92 335 6 14

Cycle 205 GMT 4/12/2018 3: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 25 14.18 464 6 6
2 1015.56 3 11.57 1910 6 6
3 1136.24 120 12.39 355 6 6
4 1147.12 101 7.06 1955 6 6
5 1150.72 99 8.15 1988 6 6
6 77.92 45 13.89 459 6 7
7 0.04 181 13.97 336 6 16

Cycle 204 GMT 24/11/2018 8:26: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.48 27 14.25 482 6 6
2 985.92 99 8.97 1762 6 6
3 103.76 44 13.83 503 6 7
4 0.16 181 14.04 328 6 16

Cycle 203 GMT 14/11/2018 14:34: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.88 27 14.25 464 6 6
2 944.32 -1 14.25 464 6 6
3 1902.60 120 13.27 396 6 6
4 1908.68 101 9.04 3081 6 6
5 1903.76 99 8.91 3074 6 6
6 103.96 44 13.94 505 6 7
7 0.16 181 14.12 337 6 17

Cycle 202 GMT 13/11/2018 19:26:58

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.92 27 14.00 500 6 6
2 935.08 -1 14.00 500 6 6
3 1176.76 120 12.55 355 6 6
4 1185.92 101 7.61 2018 6 6
5 1186.56 99 8.67 2037 6 6
6 75.40 45 13.98 451 6 7
7 0.12 181 14.15 328 6 17

Cycle 201 GMT 4/11/2018 0:55: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.92 27 14.12 500 6 6
2 985.68 99 9.30 1756 6 6
3 94.08 44 13.87 506 6 8
4 -0.08 181 14.04 336 6 17

Cycle 200 GMT 25/10/2018 7:10:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.08 27 14.12 482 6 6
2 1054.80 120 13.41 386 6 6
3 1054.80 101 10.43 1908 6 6
4 1050.32 99 10.38 1880 6 6
5 0.04 181 14.04 343 6 16

Cycle 199 GMT 24/10/2018 12:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.92 27 14.12 500 6 6
2 1102.48 120 12.68 361 6 6
3 1102.44 101 8.05 1915 6 6
4 1099.52 99 9.06 1930 6 6
5 52.00 45 14.00 431 6 8
6 0.04 181 14.04 348 6 20

Cycle 198 GMT 14/10/2018 18:46: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.96 27 14.12 500 6 6
2 976.72 99 9.34 1755 6 6
3 86.12 44 13.92 482 6 7
4 0.04 181 14.10 340 6 15

Cycle 197 GMT 5/10/2018 1: 6:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.88 27 14.18 482 6 6
2 1177.28 120 13.43 393 6 6
3 1177.24 101 10.37 2071 6 6
4 1172.40 99 10.36 2052 6 6
5 0.12 180 14.08 341 6 16

Cycle 196 GMT 4/10/2018 6:36: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.20 27 14.18 482 6 6
2 1049.80 120 12.74 379 6 6
3 1050.48 101 8.27 1860 6 6
4 1047.96 99 9.40 1863 6 6
5 51.32 45 14.04 412 6 8
6 -0.04 181 14.15 338 6 20

Cycle 195 GMT 24/ 9/2018 12:34:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.76 27 14.18 482 6 6
2 997.44 99 9.50 1777 6 6
3 99.96 44 13.94 501 6 7
4 0.12 181 14.18 330 6 16

Cycle 194 GMT 14/ 9/2018 18:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.32 25 14.06 482 6 6
2 1052.88 1 11.69 1928 6 6
3 1022.64 1 11.07 1928 6 6
4 1904.36 120 13.25 401 6 6
5 1907.48 101 9.28 3098 6 6
6 1899.64 99 9.41 3060 6 6
7 84.28 45 14.00 469 6 7
8 0.12 181 14.23 333 6 13

Cycle 193 GMT 13/ 9/2018 23:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.60 27 14.18 464 6 6
2 1173.80 120 12.80 368 6 6
3 1185.52 101 8.13 2040 6 6
4 1186.68 99 9.30 2059 6 6
5 50.12 45 14.07 410 6 7
6 0.12 181 14.17 339 6 18

Cycle 192 GMT 4/ 9/2018 5:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.56 25 14.25 482 6 6
2 1065.96 2 12.31 1964 6 6
3 1028.36 1 11.69 1928 6 6
4 1025.32 99 9.34 1813 6 6
5 104.68 44 13.96 484 6 7
6 0.08 180 14.22 319 6 14

Cycle 191 GMT 25/ 8/2018 11: 6: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.20 27 14.25 464 6 6
2 931.24 -1 14.25 464 6 6
3 1900.44 120 13.31 410 6 6
4 1907.12 101 9.40 3307 6 6
5 1904.12 99 9.85 3082 6 6
6 100.44 45 13.96 496 6 7
7 0.12 181 14.25 324 6 12

Cycle 190 GMT 24/ 8/2018 16:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.00 30 14.12 482 6 6
2 910.72 -1 14.12 482 6 6
3 1153.88 120 12.77 370 6 6
4 1163.52 101 8.03 2016 6 6
5 1164.52 99 9.43 2028 6 6
6 92.72 45 13.98 485 6 7
7 0.12 181 14.20 330 6 18

Cycle 189 GMT 14/ 8/2018 21:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.52 27 14.18 464 6 6
2 934.76 -1 14.18 464 6 6
3 1001.12 99 9.28 1782 6 6
4 107.84 45 13.91 511 6 7
5 0.08 181 14.22 327 6 14

Cycle 188 GMT 5/ 8/2018 4: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.88 27 14.18 482 6 6
2 1907.32 120 13.34 407 6 6
3 1913.76 101 9.14 3101 6 6
4 1908.72 99 9.40 3091 6 6
5 105.72 45 13.98 502 6 7
6 0.12 181 14.24 328 6 12

Cycle 187 GMT 4/ 8/2018 9:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.44 26 14.25 482 6 6
2 1007.92 4 12.12 1857 6 6
3 1153.92 120 12.67 364 6 6
4 1166.12 101 7.85 1996 6 6
5 1169.64 99 9.47 2037 6 6
6 90.60 45 13.98 467 6 8
7 0.04 181 14.18 326 6 20

Cycle 186 GMT 25/ 7/2018 14:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.52 27 14.18 482 6 6
2 985.36 99 9.23 1769 6 6
3 108.20 44 13.96 501 6 7
4 0.16 181 14.21 324 6 17

Cycle 185 GMT 15/ 7/2018 20:59: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.96 27 14.18 482 6 6
2 1908.08 120 13.36 396 6 6
3 1914.44 101 9.03 3098 6 6
4 1909.32 99 9.42 3093 6 6
5 101.28 45 13.99 491 6 7
6 0.08 181 14.24 323 6 14

Cycle 184 GMT 15/ 7/2018 2: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.72 28 14.25 464 6 6
2 934.96 -1 14.25 464 6 6
3 1178.88 120 12.68 372 6 6
4 1189.24 101 7.57 2040 6 6
5 1191.68 99 9.54 2063 6 6
6 77.72 45 14.02 440 6 7
7 0.12 181 14.21 317 6 13

Cycle 183 GMT 5/ 7/2018 7:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.76 27 14.12 482 6 6
2 995.00 99 9.04 1778 6 6
3 117.16 44 13.91 514 6 7
4 0.12 180 14.18 321 6 14

Cycle 182 GMT 25/ 6/2018 13:34: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.12 27 13.93 500 6 6
2 1910.04 120 13.30 404 6 6
3 1916.00 101 8.88 3100 6 6
4 1911.08 99 9.42 3085 6 6
5 107.24 45 13.92 507 6 7
6 0.16 180 14.20 326 6 12

Cycle 181 GMT 24/ 6/2018 18:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.72 28 14.18 482 6 6
2 1146.00 120 12.54 370 6 6
3 1156.40 101 7.09 1989 6 6
4 1160.12 99 9.60 2024 6 6
5 106.80 45 13.92 506 6 7
6 0.08 180 14.18 327 6 15

Cycle 180 GMT 15/ 6/2018 0:11: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.32 26 14.12 482 6 6
2 1036.28 1 11.69 1910 6 6
3 1019.44 1 10.63 1910 6 6
4 1012.08 99 8.57 1773 6 6
5 143.80 44 13.84 557 6 7
6 15.08 44 14.13 340 6 7
7 0.12 181 14.16 324 6 20

Cycle 179 GMT 5/ 6/2018 6: 8: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.84 26 14.06 482 6 6
2 1047.80 1 11.07 1946 6 6
3 1019.28 1 9.19 1892 6 6
4 1901.24 120 13.22 404 6 6
5 1907.76 111 8.59 3070 6 6
6 1902.52 99 9.44 3082 6 6
7 102.24 45 13.99 488 6 7
8 0.00 181 14.20 329 6 12

Cycle 178 GMT 4/ 6/2018 11:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 27 14.06 482 6 6
2 1044.04 1 11.25 1946 6 6
3 1019.80 1 9.57 1892 6 6
4 1023.64 99 7.82 1765 6 6
5 343.08 44 13.37 885 6 7
6 58.52 44 13.99 421 6 7
7 0.04 181 14.14 330 6 19

Cycle 177 GMT 25/ 5/2018 17:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.68 26 14.18 464 6 6
2 1007.04 99 8.41 1768 6 6
3 151.64 44 13.84 572 6 7
4 0.08 181 14.15 324 6 11

Cycle 176 GMT 15/ 5/2018 23:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 28 14.18 464 6 6
2 903.68 -1 14.18 464 6 6
3 1908.68 120 13.30 407 6 6
4 1914.48 111 8.62 3116 6 6
5 1908.24 99 9.48 3099 6 6
6 100.32 45 13.96 486 6 7
7 0.20 181 14.16 330 6 14

Cycle 175 GMT 15/ 5/2018 4:17: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 29 14.12 482 6 6
2 917.00 -1 14.12 482 6 6
3 981.20 99 7.81 1709 6 6
4 154.12 44 13.77 575 6 7
5 32.96 44 14.04 376 6 7
6 0.00 181 14.12 325 6 21

Cycle 174 GMT 5/ 5/2018 10:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.88 28 14.12 482 6 6
2 947.08 -1 14.12 482 6 6
3 985.88 99 8.28 1738 6 6
4 152.56 44 13.82 581 6 7
5 4.48 44 14.13 323 6 8
6 0.12 180 14.16 324 6 17

Cycle 173 GMT 25/ 4/2018 16: 6: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.92 25 14.00 482 6 6
2 1078.72 2 11.00 1982 6 6
3 1045.36 1 10.75 1928 6 6
4 1906.20 120 13.23 400 6 6
5 1910.76 111 8.79 3088 6 6
6 1902.72 99 9.52 3094 6 6
7 129.36 45 13.86 542 6 7
8 0.16 181 14.13 328 6 14

Cycle 172 GMT 24/ 4/2018 21:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.88 23 14.06 464 6 6
2 1053.64 4 12.12 1910 6 6
3 1052.92 1 11.25 1964 6 6
4 1037.80 99 7.19 1740 6 6
5 391.00 44 13.27 954 6 7
6 61.16 44 13.97 416 6 7
7 0.08 180 14.11 324 6 15

Cycle 171 GMT 15/ 4/2018 3: 3: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.72 24 14.06 482 6 6
2 1100.76 3 11.69 2017 6 6
3 1062.32 2 11.38 1982 6 6
4 1012.24 99 7.83 1734 6 6
5 319.32 44 13.47 836 6 7
6 13.24 44 14.11 322 6 7
7 0.04 181 14.14 324 6 21

Cycle 170 GMT 5/ 4/2018 9:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.24 30 14.00 482 6 6
2 873.44 -1 14.00 482 6 6
3 932.88 -1 14.00 482 6 6
4 1033.68 120 13.44 392 6 6
5 1033.68 111 10.49 1873 6 6
6 1027.68 99 10.24 1839 6 6
7 0.08 181 14.07 329 6 11

Cycle 169 GMT 4/ 4/2018 15:23: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.52 28 14.00 464 6 6
2 900.60 -1 14.00 464 6 6
3 899.92 -1 14.00 464 6 6
4 920.52 99 8.24 1626 6 6
5 199.92 44 13.65 661 6 7
6 4.52 44 14.07 324 6 8
7 0.08 180 14.11 325 6 18

Cycle 168 GMT 25/ 3/2018 21:30: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.36 27 14.06 482 6 6
2 940.84 -1 14.06 482 6 6
3 1104.04 99 7.94 1891 6 6
4 224.32 44 13.66 698 6 7
5 20.52 44 14.07 352 6 7
6 0.08 181 14.13 329 6 21

Cycle 167 GMT 18/ 3/2018 8:30: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.04 20 14.12 464 6 6
2 1025.76 5 12.06 1910 6 6
3 1055.56 3 12.50 1982 6 6
4 1065.84 2 11.32 1946 6 6
5 1025.56 1 10.38 1892 6 6
6 1111.04 120 13.39 384 6 6
7 1111.04 111 10.53 1980 6 6
8 1107.24 99 10.38 1953 6 6
9 0.08 180 14.06 332 6 14

Cycle 166 GMT 17/ 3/2018 14:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 28 14.00 482 6 6
2 1032.24 62 4.76 1546 6 6
3 982.60 45 11.86 1828 6 6
4 364.44 44 13.30 929 6 6
5 47.68 44 13.98 395 6 7
6 0.04 181 14.10 326 6 17

Cycle 165 GMT 7/ 3/2018 19:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.48 27 14.06 482 6 6
2 1060.32 62 6.01 1725 6 6
3 922.08 44 12.26 1733 6 6
4 127.84 44 13.82 530 6 7
5 0.04 181 14.13 322 6 10

Cycle 164 GMT 26/ 2/2018 1:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.16 23 14.06 464 6 6
2 938.48 -1 14.06 464 6 6
3 1116.88 120 13.31 393 6 6
4 1117.20 111 10.58 2049 6 6
5 1112.28 62 10.61 1986 6 6
6 24.52 44 14.04 355 6 7
7 0.16 181 14.07 329 6 19

Cycle 163 GMT 25/ 2/2018 6:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.48 28 14.18 464 6 6
2 1046.64 62 4.94 1634 6 6
3 990.12 45 11.88 1827 6 6
4 332.12 44 13.37 869 6 7
5 24.84 44 14.05 354 6 7
6 0.00 181 14.11 325 6 19

Cycle 162 GMT 15/ 2/2018 11:52: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.40 27 14.12 464 6 6
2 1039.84 62 6.19 1693 6 6
3 903.72 45 12.26 1701 6 6
4 167.24 44 13.73 603 6 7
5 0.20 181 14.12 321 6 10

Cycle 161 GMT 5/ 2/2018 17:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.56 28 14.00 464 6 6
2 877.80 -1 14.00 464 6 6
3 891.96 -1 14.00 464 6 6
4 978.12 120 13.42 387 6 6
5 978.08 111 10.70 1788 6 6
6 973.92 62 10.51 1779 6 6
7 21.20 44 13.98 352 6 7
8 0.00 181 14.06 327 6 21

Cycle 160 GMT 4/ 2/2018 23:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 28 14.12 464 6 6
2 939.64 62 5.72 1581 6 6
3 840.04 45 12.18 1623 6 6
4 177.92 44 13.68 617 6 7
5 15.84 44 14.06 340 6 7
6 0.08 181 14.10 325 6 19

Cycle 159 GMT 26/ 1/2018 4:59: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 27 13.93 482 6 6
2 1020.28 62 6.65 1703 6 6
3 836.64 45 12.37 1618 6 6
4 144.04 44 13.78 568 6 7
5 0.08 181 14.11 323 6 15

Cycle 158 GMT 16/ 1/2018 10:58: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.60 27 14.00 482 6 6
2 1022.28 1 10.69 1910 6 6
3 1126.12 120 13.36 397 6 6
4 1126.68 111 10.37 2009 6 6
5 1121.16 62 10.33 1989 6 6
6 56.80 44 13.93 416 6 7
7 0.04 181 14.04 331 6 18

Cycle 157 GMT 15/ 1/2018 16:20: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.64 28 14.00 482 6 6
2 1004.08 62 7.54 1756 6 6
3 819.20 44 12.36 1591 6 6
4 86.56 44 13.88 458 6 7
5 0.04 181 14.13 319 6 13

Cycle 156 GMT 5/ 1/2018 22:18: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.32 26 14.06 464 6 6
2 1111.20 62 8.73 1954 6 6
3 490.44 45 13.04 1120 6 7
4 49.96 45 13.96 409 6 7
5 0.08 180 14.10 331 6 19

Cycle 155 GMT 1/ 1/2018 10:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.84 27 14.00 464 6 6
2 1471.96 120 13.26 401 6 6
3 1471.96 111 9.35 2470 6 6
4 1467.12 62 9.83 2469 6 6
5 117.04 44 13.81 529 6 7
6 0.08 181 14.07 333 6 15

Cycle 154 GMT 31/12/2017 15: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.36 28 14.00 482 6 6
2 1075.64 62 5.92 1750 6 6
3 933.96 45 11.93 1769 6 6
4 124.72 44 13.78 512 6 6
5 0.12 181 14.09 323 6 12

Cycle 153 GMT 21/12/2017 20:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.36 26 14.06 464 6 6
2 1022.36 1 10.88 1946 6 6
3 1049.84 62 6.68 1748 6 6
4 855.04 45 12.34 1635 6 6
5 97.84 44 13.84 483 6 6
6 0.60 180 14.11 323 6 14

Cycle 152 GMT 12/12/2017 2:29: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.72 27 14.12 464 6 6
2 1178.64 120 13.29 388 6 6
3 1178.60 111 10.01 2080 6 6
4 1172.72 62 10.13 2056 6 6
5 48.32 44 13.94 400 6 7
6 0.04 181 14.08 323 6 20

Cycle 151 GMT 11/12/2017 7:38: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.24 26 14.12 464 6 6
2 1066.88 2 11.07 1964 6 6
3 1038.76 62 5.75 1690 6 6
4 882.04 44 12.08 1670 6 6
5 190.88 44 13.64 622 6 7
6 17.16 44 14.04 340 6 7
7 0.04 181 14.11 321 6 22

Cycle 150 GMT 1/12/2017 13:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.24 27 13.93 482 6 6
2 950.00 -1 13.93 482 6 6
3 1030.08 1 11.00 1910 6 6
4 1068.00 62 6.33 1774 6 6
5 898.28 45 12.15 1704 6 6
6 123.40 44 13.82 506 6 6
7 11.16 44 14.09 326 6 7
8 0.08 181 14.15 323 6 18

Cycle 149 GMT 21/11/2017 18:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.36 26 14.06 464 6 6
2 1121.80 120 13.24 398 6 6
3 1121.80 111 10.29 1995 6 6
4 1117.08 62 10.35 1982 6 6
5 58.72 44 13.90 420 6 7
6 0.04 181 14.08 323 6 17

Cycle 148 GMT 21/11/2017 0:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.04 28 14.06 464 6 6
2 946.88 -1 14.06 464 6 6
3 1071.84 62 5.06 1713 6 6
4 1035.64 44 11.56 1887 6 6
5 413.32 44 13.15 995 6 7
6 74.52 44 13.89 447 6 7
7 0.16 181 14.12 322 6 19

Cycle 147 GMT 11/11/2017 5:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.88 27 14.00 464 6 6
2 1066.24 62 6.10 1758 6 6
3 930.20 44 12.03 1757 6 6
4 250.48 44 13.50 746 6 7
5 18.76 44 14.05 344 6 7
6 0.12 181 14.13 322 6 21

Cycle 146 GMT 1/11/2017 11: 1: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.76 26 13.93 482 6 6
2 1417.92 120 13.18 404 6 6
3 1417.92 111 9.44 2406 6 6
4 1412.60 62 9.85 2400 6 6
5 103.88 44 13.82 499 6 7
6 0.24 181 14.09 327 6 16

Cycle 145 GMT 31/10/2017 15:38: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.48 28 13.93 482 6 6
2 1005.28 62 5.55 1631 6 6
3 879.12 45 11.78 1670 6 6
4 140.52 44 13.74 545 6 7
5 15.12 44 14.06 337 6 7
6 0.08 181 14.13 325 6 20

Cycle 144 GMT 21/10/2017 21:10: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.64 26 14.06 482 6 6
2 1025.48 1 11.13 1910 6 6
3 1015.12 62 6.69 1752 6 6
4 839.76 45 12.20 1625 6 6
5 147.96 44 13.73 560 6 7
6 0.16 180 14.15 318 6 10

Cycle 143 GMT 12/10/2017 3: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.72 28 13.93 482 6 6
2 916.88 -1 13.93 482 6 6
3 1672.32 120 13.22 403 6 6
4 1673.36 111 8.81 2761 6 6
5 1667.76 62 9.68 2756 6 6
6 131.24 45 13.78 545 6 7
7 0.20 181 14.13 331 6 13

Cycle 142 GMT 11/10/2017 6:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.76 28 14.00 482 6 6
2 1016.84 62 5.69 1669 6 6
3 918.00 45 11.72 1729 6 6
4 124.64 44 13.76 517 6 6
5 15.24 44 14.06 328 6 7
6 0.04 181 14.14 322 6 18

Cycle 141 GMT 1/10/2017 12:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.96 26 14.06 464 6 6
2 1012.36 62 6.76 1750 6 6
3 864.80 44 12.15 1659 6 6
4 109.04 44 13.80 504 6 7
5 0.12 181 14.13 325 6 13

Cycle 140 GMT 21/ 9/2017 18:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.96 26 13.93 482 6 6
2 1063.20 2 11.13 1982 6 6
3 1020.36 1 9.57 1910 6 6
4 1906.16 120 13.18 405 6 6
5 1911.60 111 8.39 3116 6 6
6 1905.08 62 9.53 3098 6 6
7 165.56 45 13.70 612 6 7
8 34.56 45 14.03 384 6 7
9 0.00 181 14.15 328 6 19

Cycle 139 GMT 20/ 9/2017 22:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 116.12 28 14.00 482 6 6
2 977.56 62 6.09 1658 6 6
3 849.44 44 11.95 1638 6 6
4 171.16 44 13.62 609 6 7
5 0.12 181 14.08 331 6 12

Cycle 138 GMT 11/ 9/2017 4:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.72 26 14.00 482 6 6
2 998.80 62 6.95 1745 6 6
3 830.44 44 12.19 1618 6 6
4 102.16 44 13.83 484 6 7
5 0.16 181 14.14 324 6 11

Cycle 137 GMT 1/ 9/2017 10: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.76 26 13.75 500 6 6
2 1901.32 120 13.23 406 6 6
3 1905.44 111 8.73 3101 6 6
4 1897.28 62 9.62 3077 6 6
5 140.28 45 13.75 567 6 7
6 29.32 45 14.05 372 6 7
7 0.04 181 14.13 338 6 19

Cycle 136 GMT 31/ 8/2017 14:19:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 28 14.00 482 6 6
2 996.80 62 6.10 1702 6 6
3 844.80 45 11.94 1616 6 6
4 172.76 44 13.58 618 6 7
5 32.32 44 14.03 362 6 8
6 0.08 181 14.08 339 6 22

Cycle 135 GMT 21/ 8/2017 20:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 25 13.93 482 6 6
2 1033.40 1 11.38 1928 6 6
3 1022.60 1 10.75 1964 6 6
4 1018.52 62 6.83 1743 6 6
5 832.04 44 12.22 1620 6 6
6 95.16 44 13.84 478 6 7
7 0.08 181 14.11 329 6 10

Cycle 134 GMT 12/ 8/2017 1:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 26 13.75 500 6 6
2 1903.08 120 13.18 410 6 6
3 1906.24 111 8.73 3086 6 6
4 1897.48 62 9.59 3075 6 6
5 139.44 45 13.75 571 6 7
6 29.48 45 14.04 379 6 7
7 0.08 181 14.12 342 6 24

Cycle 133 GMT 11/ 8/2017 6: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.76 28 14.00 482 6 6
2 977.28 62 6.08 1681 6 6
3 831.92 45 11.93 1606 6 6
4 113.64 44 13.77 507 6 7
5 25.48 44 14.03 355 6 7
6 0.04 181 14.10 334 6 21

Cycle 132 GMT 1/ 8/2017 11:51: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.08 28 14.12 464 6 6
2 939.96 -1 14.12 464 6 6
3 1005.92 62 6.84 1773 6 6
4 817.64 44 12.23 1601 6 6
5 141.48 44 13.70 569 6 7
6 0.08 181 14.09 336 6 14

Cycle 131 GMT 22/ 7/2017 17:41: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.52 26 14.12 464 6 6
2 1901.76 120 13.20 408 6 6
3 1906.32 111 8.90 3097 6 6
4 1898.36 62 9.58 3090 6 6
5 137.80 45 13.74 561 6 7
6 13.16 45 14.10 345 6 7
7 0.08 181 14.17 337 6 21

Cycle 130 GMT 21/ 7/2017 21:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.36 28 13.93 482 6 6
2 996.76 62 6.02 1691 6 6
3 852.88 45 11.90 1643 6 6
4 130.20 44 13.74 533 6 6
5 14.20 44 14.07 333 6 7
6 0.04 181 14.13 328 6 21

Cycle 129 GMT 12/ 7/2017 3:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.32 28 14.06 482 6 6
2 963.88 62 6.96 1693 6 6
3 775.80 45 12.21 1539 6 6
4 121.72 44 13.77 519 6 7
5 0.08 180 14.10 332 6 12

Cycle 128 GMT 2/ 7/2017 9:37: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.76 29 14.00 482 6 6
2 947.20 -1 14.00 482 6 6
3 1909.12 120 13.18 416 6 6
4 1914.60 111 8.81 3105 6 6
5 1907.64 62 9.53 3121 6 6
6 146.00 45 13.74 579 6 7
7 15.08 45 14.12 347 6 7
8 0.08 181 14.18 336 6 20

Cycle 127 GMT 1/ 7/2017 13:28: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.84 28 14.12 482 6 6
2 996.08 62 6.21 1698 6 6
3 849.12 45 11.84 1639 6 6
4 157.76 44 13.61 596 6 7
5 0.08 181 14.09 327 6 15

Cycle 126 GMT 21/ 6/2017 19:21: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.28 28 14.12 482 6 6
2 1002.88 62 6.84 1755 6 6
3 834.76 44 12.14 1621 6 6
4 110.44 44 13.83 494 6 7
5 0.08 181 14.16 329 6 13

Cycle 125 GMT 12/ 6/2017 1: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.84 26 14.06 482 6 6
2 1067.52 2 11.13 1982 6 6
3 1024.96 1 10.13 1928 6 6
4 1911.36 120 13.16 412 6 6
5 1918.16 111 9.08 3128 6 6
6 1912.08 62 9.58 3119 6 6
7 143.36 45 13.75 577 6 7
8 0.16 181 14.17 336 6 13

Cycle 124 GMT 11/ 6/2017 5:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.52 28 14.06 464 6 6
2 1000.72 62 6.32 1708 6 6
3 825.76 45 11.96 1603 6 6
4 150.36 44 13.67 577 6 7
5 0.12 180 14.12 325 6 13

Cycle 123 GMT 1/ 6/2017 11:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 27 14.12 482 6 6
2 1028.12 1 11.19 1946 6 6
3 1019.60 62 7.15 1807 6 6
4 821.48 44 12.21 1605 6 6
5 136.24 44 13.72 551 6 7
6 0.12 181 14.13 321 6 14

Cycle 122 GMT 22/ 5/2017 17:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 29 13.93 482 6 6
2 944.68 -1 13.93 482 6 6
3 1906.44 120 13.20 409 6 6
4 1911.52 111 9.18 3111 6 6
5 1904.00 62 9.67 3121 6 6
6 127.00 45 13.74 549 6 7
7 0.12 181 14.16 336 6 14

Cycle 121 GMT 21/ 5/2017 21:34: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.44 27 14.12 464 6 6
2 1012.36 62 7.11 1769 6 6
3 817.96 45 12.05 1596 6 6
4 134.96 44 13.69 553 6 7
5 0.08 181 14.10 333 6 17

Cycle 120 GMT 12/ 5/2017 3:30: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.68 29 14.18 464 6 6
2 929.64 -1 14.18 464 6 6
3 985.16 62 7.60 1763 6 6
4 603.08 44 12.66 1291 6 6
5 90.84 44 13.88 459 6 7
6 0.00 181 14.12 336 6 14

Cycle 119 GMT 2/ 5/2017 9:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.68 29 14.06 482 6 6
2 1902.00 120 13.18 416 6 6
3 1906.88 111 9.35 3102 6 6
4 1898.68 62 9.82 3091 6 6
5 115.88 45 13.84 522 6 7
6 0.16 181 14.18 337 6 11

Cycle 118 GMT 1/ 5/2017 13:51: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.76 27 14.06 482 6 6
2 982.56 62 7.44 1754 6 6
3 784.72 44 12.31 1542 6 6
4 120.12 44 13.77 522 6 7
5 0.12 181 14.12 337 6 12

Cycle 117 GMT 21/ 4/2017 19:51: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.20 23 14.12 482 6 6
2 1046.28 3 12.43 1946 6 6
3 1079.76 2 12.00 1982 6 6
4 1037.80 1 11.50 1928 6 6
5 1180.72 120 12.76 380 6 6
6 1191.56 111 9.04 2063 6 6
7 1189.40 62 9.98 2089 6 6
8 66.20 44 13.93 436 6 7
9 0.08 181 14.15 334 6 16

Cycle 116 GMT 12/ 4/2017 1:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.40 22 14.18 482 6 6
2 1053.24 4 12.12 1946 6 6
3 1065.24 2 11.50 1946 6 6
4 1042.80 1 10.94 1928 6 6
5 1915.52 120 13.21 414 6 6
6 1920.80 111 9.92 3139 6 6
7 1912.56 62 10.10 3137 6 6
8 99.12 45 13.97 495 6 7
9 0.16 181 14.26 340 6 12

Cycle 115 GMT 11/ 4/2017 5:28: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.96 27 14.06 500 6 6
2 2004.48 120 11.48 379 6 6
3 2009.44 110 4.95 2767 6 6
4 2014.16 62 8.76 3250 6 6
5 1837.76 45 10.91 3045 6 6
6 913.20 45 12.38 1764 6 6
7 107.88 44 13.91 515 6 7
8 0.16 181 14.25 331 6 12

Cycle 114 GMT 1/ 4/2017 4:49: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.44 27 14.18 482 6 6
2 2005.96 120 11.63 376 6 6
3 2010.16 101 4.96 2780 6 6
4 2013.80 62 8.74 3233 6 6
5 1821.56 45 10.97 2986 6 6
6 933.12 45 12.38 1780 6 6
7 109.04 45 13.93 506 6 7
8 0.08 180 14.24 334 6 15

Cycle 113 GMT 22/ 3/2017 4:18: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.08 27 14.12 500 6 6
2 2002.64 120 11.65 376 6 6
3 2007.00 101 4.98 2850 6 6
4 2010.80 62 9.06 3241 6 6
5 1817.72 45 11.02 3005 6 6
6 867.64 45 12.47 1674 6 6
7 100.16 45 13.95 487 6 7
8 0.12 181 14.25 332 6 13

Cycle 112 GMT 12/ 3/2017 3:55: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.00 27 14.25 482 6 6
2 2001.76 120 11.47 367 6 6
3 2005.96 101 4.96 2752 6 6
4 2009.76 62 9.10 3243 6 6
5 1826.12 45 11.01 2993 6 6
6 690.92 45 12.75 1430 6 6
7 97.84 45 13.95 486 6 7
8 0.16 181 14.23 331 6 14

Cycle 111 GMT 2/ 3/2017 3:21: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.64 27 14.18 482 6 6
2 2005.32 120 11.42 374 6 6
3 2009.60 51 4.88 2330 6 6
4 2011.72 62 6.46 3388 6 6
5 1919.00 33 11.24 3145 6 6
6 1729.00 33 11.70 2893 6 6
7 847.32 33 12.82 1651 6 6
8 176.36 33 13.80 632 6 7
9 47.56 33 14.14 404 6 7
10 0.00 190 14.23 336 6 21

Cycle 110 GMT 20/ 2/2017 2: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.44 27 14.12 482 6 6
2 2016.84 120 11.62 384 6 6
3 2022.76 51 4.88 2287 6 6
4 2025.60 62 6.31 3334 6 6
5 1944.96 33 11.16 3215 6 6
6 1567.44 33 11.89 2676 6 6
7 921.20 33 12.71 1779 6 6
8 130.40 33 13.89 559 6 7
9 73.40 33 14.05 461 6 7
10 0.12 190 14.24 341 6 18

Cycle 109 GMT 10/ 2/2017 0:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 25 14.18 464 6 6
2 1068.52 2 11.63 1982 6 6
3 1030.28 1 11.00 1910 6 6
4 1186.68 3 4.75 1410 6 6
5 1857.92 25 4.88 2129 6 6
6 1858.40 63 7.13 3073 6 6
7 1708.84 33 11.51 2847 6 6
8 1089.48 33 12.49 1988 6 6
9 224.44 33 13.69 701 6 7
10 74.88 33 14.06 432 6 7
11 0.16 190 14.21 336 6 14

Cycle 108 GMT 30/ 1/2017 23:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.80 27 14.25 464 6 6
2 932.48 -1 14.25 464 6 6
3 1161.36 3 4.75 1410 6 6
4 1863.12 25 4.86 2045 6 6
5 1862.80 63 6.14 3071 6 6
6 1731.64 33 11.48 2904 6 6
7 1344.40 33 12.19 2341 6 6
8 485.76 33 13.29 1109 6 7
9 90.40 34 14.03 460 6 7
10 46.64 34 14.14 406 6 7
11 0.04 191 14.24 333 6 20

Cycle 107 GMT 20/ 1/2017 21:58: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.44 27 14.25 482 6 6
2 1186.84 3 4.75 1383 6 6
3 1861.16 25 4.86 2053 6 6
4 1861.32 63 6.36 3067 6 6
5 1732.72 33 11.50 2892 6 6
6 1346.68 33 12.19 2342 6 6
7 469.52 33 13.33 1087 6 7
8 107.56 34 13.96 506 6 7
9 0.08 190 14.22 337 6 14

Cycle 106 GMT 10/ 1/2017 20:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.64 27 14.18 482 6 6
2 1151.88 3 4.75 1374 6 6
3 1872.56 25 4.86 2078 6 6
4 1872.32 63 6.57 3092 6 6
5 1736.72 33 11.56 2889 6 6
6 1333.32 33 12.19 2344 6 6
7 439.60 33 13.38 1040 6 7
8 98.44 34 13.97 502 6 7
9 0.08 190 14.22 336 6 17

Cycle 105 GMT 31/12/2016 19:39:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.20 27 14.12 482 6 6
2 1158.56 3 4.75 1374 6 6
3 1864.56 25 4.88 2119 6 6
4 1864.76 63 7.18 3070 6 6
5 1710.12 33 11.57 2851 6 6
6 1273.00 33 12.26 2249 6 6
7 209.32 34 13.72 694 6 6
8 67.84 34 14.10 442 6 7
9 0.16 191 14.23 335 6 17

Cycle 104 GMT 21/12/2016 18:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.40 27 14.12 500 6 6
2 1181.40 4 4.75 1374 6 6
3 1865.60 25 4.92 2365 6 6
4 1865.52 63 7.94 3041 6 6
5 1684.64 33 11.63 2827 6 6
6 809.08 33 12.83 1602 6 6
7 156.72 33 13.88 590 6 7
8 44.48 33 14.16 386 6 7
9 0.16 191 14.19 342 6 17

Cycle 103 GMT 11/12/2016 17:42: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.20 26 14.18 482 6 6
2 1185.00 4 4.78 1410 6 6
3 1864.00 25 4.98 2562 6 6
4 1863.96 63 8.36 3031 6 6
5 1483.00 33 11.90 2551 6 6
6 832.64 33 12.81 1631 6 6
7 158.08 34 13.86 595 6 7
8 35.64 34 14.16 394 6 7
9 0.08 190 14.20 339 6 20

Cycle 102 GMT 1/12/2016 16:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.88 29 14.25 482 6 6
2 949.76 -1 14.25 482 6 6
3 1188.96 3 4.78 1490 6 6
4 1847.48 16 4.96 2468 6 6
5 1847.52 63 8.25 2996 6 6
6 1658.48 33 11.63 2807 6 6
7 792.96 33 12.86 1572 6 6
8 152.16 33 13.83 600 6 7
9 39.88 33 14.13 397 6 7
10 0.08 190 14.19 342 6 18

Cycle 101 GMT 21/11/2016 16: 1: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.40 27 14.18 482 6 6
2 967.52 -1 14.18 482 6 6
3 1019.36 1 9.94 1892 6 6
4 2006.56 15 4.86 1990 6 6
5 2009.60 63 7.89 3217 6 6
6 1839.92 33 11.42 3054 6 6
7 1209.12 33 12.31 2168 6 6
8 300.56 34 13.55 840 6 7
9 80.72 34 14.05 464 6 7
10 0.08 190 14.22 336 6 15

Cycle 100 GMT 11/11/2016 15: 6: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.64 27 14.25 482 6 6
2 2000.64 15 4.94 2273 6 6
3 2002.88 62 8.56 3251 6 6
4 1818.00 34 11.37 3018 6 6
5 957.16 33 12.61 1812 6 6
6 159.68 33 13.83 609 6 6
7 84.92 33 14.07 475 6 7
8 0.04 190 14.21 338 6 14

Cycle 99 GMT 1/11/2016 14:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.68 28 14.25 482 6 6
2 968.12 -1 14.25 482 6 6
3 2003.00 15 4.96 2380 6 6
4 2004.84 62 8.51 3237 6 6
5 1821.04 33 11.35 3017 6 6
6 1137.88 33 12.32 2083 6 6
7 236.52 33 13.67 736 6 7
8 62.36 33 14.13 429 6 7
9 0.08 190 14.21 328 6 13

Cycle 98 GMT 22/10/2016 13:22:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.44 26 14.25 482 6 6
2 1030.16 1 11.32 1946 6 6
3 1124.16 4 5.34 1678 6 6
4 1825.48 11 6.46 2763 6 6
5 1825.32 62 9.48 2985 6 6
6 1243.40 33 12.19 2219 6 6
7 390.60 33 13.38 995 6 7
8 100.92 33 13.95 510 6 7
9 0.12 191 14.20 336 6 14

Cycle 97 GMT 12/10/2016 12:22: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.12 27 14.25 482 6 6
2 973.20 -1 14.25 482 6 6
3 1027.24 1 11.07 1928 6 6
4 1120.88 3 5.82 1749 6 6
5 1827.96 11 6.91 2899 6 6
6 1827.04 62 9.73 2985 6 6
7 1210.04 33 12.25 2171 6 6
8 338.80 33 13.51 898 6 7
9 81.52 33 14.04 477 6 7
10 0.12 191 14.16 339 6 14

Cycle 96 GMT 2/10/2016 11:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.16 27 14.18 482 6 6
2 2002.72 62 8.36 3094 6 6
3 1821.60 33 11.48 3012 6 6
4 1187.04 33 12.31 2138 6 6
5 278.68 33 13.61 798 6 7
6 72.40 33 14.07 461 6 7
7 0.08 190 14.17 336 6 16

Cycle 95 GMT 22/ 9/2016 10:10:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.40 27 14.12 500 6 6
2 2001.92 62 8.25 3105 6 6
3 1825.56 33 11.45 3025 6 6
4 1169.44 33 12.31 2132 6 6
5 283.20 33 13.59 819 6 7
6 69.64 33 14.02 466 6 7
7 0.04 190 14.15 338 6 16

Cycle 94 GMT 12/ 9/2016 9:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.84 26 14.25 482 6 6
2 2002.12 62 8.45 3123 6 6
3 1829.20 33 11.39 3033 6 6
4 1172.88 33 12.32 2134 6 6
5 301.76 33 13.54 852 6 7
6 67.76 33 14.05 461 6 7
7 0.16 191 14.16 338 6 17

Cycle 93 GMT 2/ 9/2016 8: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.88 26 14.18 482 6 6
2 2002.60 63 8.83 3179 6 6
3 1829.36 33 11.38 3043 6 6
4 1153.12 33 12.33 2090 6 6
5 219.80 33 13.68 725 6 7
6 56.72 33 14.11 426 6 7
7 -0.08 190 14.16 340 6 17

Cycle 92 GMT 23/ 8/2016 7:31: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.48 27 14.25 446 6 6
2 958.64 -1 14.25 446 6 6
3 1019.12 1 9.82 1875 6 6
4 2000.64 63 8.96 3168 6 6
5 1817.52 33 11.41 3022 6 6
6 1132.16 33 12.36 2066 6 6
7 196.88 33 13.75 668 6 7
8 54.64 33 14.11 430 6 7
9 0.08 190 14.15 339 6 15

Cycle 91 GMT 13/ 8/2016 6:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.32 26 14.18 464 6 6
2 1026.68 1 11.13 1928 6 6
3 1999.16 63 9.06 3175 6 6
4 1620.68 33 11.68 2755 6 6
5 975.32 33 12.56 1847 6 6
6 144.92 33 13.86 587 6 7
7 46.00 33 14.11 415 6 7
8 0.00 190 14.15 330 6 19

Cycle 90 GMT 3/ 8/2016 5:31: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.44 26 14.18 464 6 6
2 972.16 -1 14.18 464 6 6
3 1028.40 1 11.07 1928 6 6
4 1986.56 63 9.11 3166 6 6
5 1573.08 33 11.73 2679 6 6
6 740.00 33 12.88 1497 6 6
7 135.08 33 13.87 571 6 7
8 32.64 33 14.15 392 6 7
9 0.00 190 14.12 340 6 21

Cycle 89 GMT 24/ 7/2016 4:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.04 26 14.12 482 6 6
2 1982.84 62 9.12 3166 6 6
3 1619.16 33 11.67 2767 6 6
4 775.52 33 12.81 1568 6 6
5 159.24 33 13.82 608 6 7
6 41.64 33 14.17 400 6 7
7 -0.04 190 14.13 340 6 14

Cycle 88 GMT 14/ 7/2016 2:47: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.04 25 14.12 482 6 6
2 1030.24 1 11.25 1964 6 6
3 1990.52 63 9.34 3178 6 6
4 1592.60 33 11.74 2694 6 6
5 937.96 33 12.60 1801 6 6
6 125.52 33 13.91 547 6 7
7 38.52 33 14.17 385 6 7
8 0.04 191 14.13 336 6 17

Cycle 87 GMT 4/ 7/2016 1:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.32 27 14.25 446 6 6
2 972.48 -1 14.25 446 6 6
3 2005.00 63 9.30 3195 6 6
4 1619.76 33 11.67 2741 6 6
5 951.92 33 12.58 1822 6 6
6 126.80 33 13.93 548 6 7
7 39.76 34 14.14 395 6 7
8 0.08 190 14.13 331 6 20

Cycle 86 GMT 24/ 6/2016 0:22: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.12 26 14.18 464 6 6
2 2006.96 63 9.45 3216 6 6
3 1808.56 33 11.45 3007 6 6
4 891.32 33 12.65 1733 6 6
5 124.72 33 13.91 537 6 7
6 34.04 33 14.18 377 6 7
7 0.04 190 14.18 320 6 19

Cycle 85 GMT 13/ 6/2016 23:11: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.28 26 14.18 482 6 6
2 1970.12 63 9.49 3154 6 6
3 1583.88 33 11.74 2696 6 6
4 914.40 33 12.64 1761 6 6
5 117.96 33 13.95 514 6 7
6 31.56 34 14.15 367 6 7
7 0.12 190 14.15 321 6 18

Cycle 84 GMT 3/ 6/2016 22: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.32 26 14.25 464 6 6
2 2004.20 63 9.42 3229 6 6
3 1590.88 33 11.74 2697 6 6
4 718.16 33 12.92 1486 6 6
5 123.68 34 13.91 545 6 7
6 27.92 34 14.17 377 6 7
7 0.04 190 14.10 334 6 18

Cycle 83 GMT 24/ 5/2016 20:52: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.64 26 14.18 482 6 6
2 1979.00 63 9.55 3177 6 6
3 1581.88 33 11.75 2711 6 6
4 712.52 33 12.91 1473 6 6
5 120.32 33 13.92 529 6 7
6 26.76 33 14.14 386 6 7
7 0.08 191 14.07 345 6 19

Cycle 82 GMT 14/ 5/2016 19:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.80 27 14.25 464 6 6
2 961.12 -1 14.25 464 6 6
3 1021.24 1 9.44 1892 6 6
4 2001.08 63 9.73 3203 6 6
5 1421.92 33 12.00 2454 6 6
6 763.84 33 12.87 1544 6 6
7 123.52 34 13.84 565 6 7
8 25.92 34 14.13 391 6 7
9 0.08 191 14.05 348 6 22

Cycle 81 GMT 4/ 5/2016 18:27: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.80 28 14.18 500 6 6
2 927.76 -1 14.18 500 6 6
3 1999.00 63 9.71 3209 6 6
4 1575.12 33 11.81 2705 6 6
5 704.04 33 12.96 1458 6 6
6 112.80 33 13.93 522 6 7
7 27.16 33 14.18 362 6 7
8 0.04 190 14.11 326 6 19

Cycle 80 GMT 24/ 4/2016 17:16: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 26 14.18 500 6 6
2 1064.76 2 12.12 1982 6 6
3 1024.84 1 11.88 1892 6 6
4 1970.68 63 10.13 3173 6 6
5 1387.36 33 12.10 2423 6 6
6 525.48 33 13.22 1190 6 7
7 75.24 34 14.02 456 6 7
8 0.16 191 14.15 320 6 16

Cycle 79 GMT 14/ 4/2016 15:56: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.88 28 14.18 482 6 6
2 939.24 -1 14.18 482 6 6
3 2004.64 63 9.26 3648 6 6
4 1856.32 33 11.58 3075 6 6
5 1241.24 33 12.33 2223 6 6
6 564.28 33 13.15 1256 6 7
7 73.08 34 14.02 462 6 7
8 -0.08 190 14.10 333 6 13

Cycle 78 GMT 4/ 4/2016 15:11: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.12 26 14.18 500 6 6
2 1044.24 1 12.12 1910 6 6
3 1023.88 1 11.38 1928 6 6
4 2003.92 50 9.93 3228 6 6
5 1818.28 27 11.72 3027 6 6
6 1033.44 27 12.63 1946 6 6
7 389.80 26 13.47 978 6 7
8 79.56 26 14.02 467 6 7
9 22.32 26 14.19 361 6 7
10 0.00 190 14.10 323 6 17

Cycle 77 GMT 25/ 3/2016 13:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.08 27 14.18 482 6 6
2 945.60 -1 14.18 482 6 6
3 2004.48 50 9.97 3202 6 6
4 1833.40 27 11.67 3079 6 6
5 1218.28 27 12.45 2202 6 6
6 556.76 26 13.21 1253 6 7
7 89.52 26 13.99 491 6 7
8 48.44 26 14.15 398 6 7
9 0.20 190 14.10 324 6 18

Cycle 76 GMT 15/ 3/2016 12:54: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.56 26 14.18 482 6 6
2 1022.96 1 10.32 1892 6 6
3 1022.36 1 9.38 1857 6 6
4 2006.80 50 10.06 3214 6 6
5 1832.20 27 11.70 3040 6 6
6 1190.04 27 12.46 2166 6 6
7 347.08 26 13.47 923 6 7
8 79.32 26 14.04 470 6 7
9 20.84 26 14.20 376 6 7
10 0.04 190 14.09 324 6 17

Cycle 75 GMT 5/ 3/2016 11:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.12 27 14.25 446 6 6
2 929.44 -1 14.25 446 6 6
3 2002.96 50 10.05 3175 6 6
4 1817.40 27 11.73 3027 6 6
5 1181.24 27 12.49 2137 6 6
6 518.28 26 13.25 1184 6 7
7 75.20 26 14.05 450 6 7
8 39.64 26 14.15 395 6 7
9 0.12 190 14.09 326 6 15

Cycle 74 GMT 24/ 2/2016 10:56: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.84 26 14.18 482 6 6
2 1048.16 1 11.75 2017 6 6
3 1021.80 1 11.38 1928 6 6
4 2002.08 50 10.18 3207 6 6
5 1632.24 27 11.96 2780 6 6
6 1033.48 26 12.65 1946 6 6
7 217.08 26 13.75 705 6 7
8 59.12 26 14.08 431 6 7
9 31.60 26 14.13 390 6 7
10 0.04 190 14.07 337 6 19

Cycle 73 GMT 14/ 2/2016 9:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 101.76 26 14.18 464 6 6
2 2000.76 50 10.10 3206 6 6
3 1819.16 27 11.73 3054 6 6
4 1172.92 27 12.50 2150 6 6
5 324.12 26 13.51 884 6 7
6 70.52 26 14.02 472 6 7
7 0.16 191 14.05 352 6 15

Cycle 72 GMT 4/ 2/2016 8:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.04 27 14.25 446 6 6
2 954.92 -1 14.25 446 6 6
3 2001.40 50 10.17 3200 6 6
4 1824.32 27 11.75 3044 6 6
5 1189.64 27 12.46 2169 6 6
6 320.60 26 13.54 882 6 7
7 70.48 26 14.04 457 6 7
8 17.92 26 14.17 379 6 7
9 0.00 190 14.07 328 6 21

Cycle 71 GMT 25/ 1/2016 7:25: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 102.80 26 14.18 482 6 6
2 2002.60 50 10.23 3198 6 6
3 1817.76 27 11.80 3053 6 6
4 1170.36 27 12.50 2147 6 6
5 505.36 26 13.29 1158 6 7
6 64.96 26 14.05 432 6 7
7 16.52 26 14.18 352 6 7
8 -0.04 190 14.00 333 6 20

Cycle 70 GMT 15/ 1/2016 6:36: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.44 26 14.18 464 6 6
2 2004.48 50 10.16 3214 6 6
3 1809.60 27 11.77 3046 6 6
4 1161.04 27 12.51 2121 6 6
5 491.60 26 13.30 1145 6 7
6 67.24 26 14.05 442 6 7
7 18.24 26 14.21 353 6 7
8 0.00 190 14.07 323 6 18

Cycle 69 GMT 5/ 1/2016 6: 0: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.92 28 14.18 500 6 6
2 935.24 -1 14.18 500 6 6
3 2005.84 50 10.09 3207 6 6
4 1814.80 27 11.77 3043 6 6
5 1170.92 27 12.49 2147 6 6
6 506.24 26 13.28 1166 6 7
7 69.52 26 14.02 444 6 7
8 36.84 26 14.14 390 6 7
9 0.08 190 14.02 342 6 17

Cycle 68 GMT 26/12/2015 5:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.68 26 14.18 500 6 6
2 1041.20 1 11.75 1946 6 6
3 2002.72 50 10.28 3201 6 6
4 1596.64 27 12.06 2717 6 6
5 978.96 27 12.77 1848 6 6
6 331.96 26 13.59 869 6 7
7 64.64 26 14.05 432 6 7
8 0.12 191 14.08 319 6 12

Cycle 67 GMT 16/12/2015 4: 1: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.96 28 14.31 446 6 6
2 923.68 -1 14.31 446 6 6
3 2003.24 50 10.15 3179 6 6
4 1808.32 27 11.78 3020 6 6
5 1137.92 27 12.55 2087 6 6
6 454.20 26 13.38 1066 6 7
7 96.92 26 14.00 482 6 7
8 22.32 26 14.21 357 6 7
9 0.08 191 14.04 325 6 21

Cycle 66 GMT 6/12/2015 3: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 26 14.25 500 6 6
2 1037.40 1 11.25 1928 6 6
3 1028.12 1 10.69 1892 6 6
4 1784.64 50 10.44 2888 6 6
5 1595.00 27 12.08 2699 6 6
6 945.52 27 12.77 1809 6 6
7 272.48 26 13.64 799 6 7
8 57.64 26 14.12 416 6 7
9 16.60 26 14.21 343 6 7
10 0.08 190 14.01 320 6 30

Cycle 65 GMT 26/11/2015 2:25: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.24 27 14.18 482 6 6
2 958.52 -1 14.18 482 6 6
3 1869.24 50 9.76 3240 6 6
4 1711.08 25 12.05 2887 6 6
5 1301.96 25 12.47 2339 6 6
6 636.08 25 13.17 1364 6 7
7 108.56 25 13.99 505 6 7
8 56.88 25 14.15 399 6 7
9 0.04 191 14.08 328 6 14

Cycle 64 GMT 16/11/2015 1:15:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.44 27 14.25 482 6 6
2 1754.00 50 9.74 3205 6 6
3 1620.28 25 12.09 2758 6 6
4 1221.48 25 12.57 2213 6 6
5 574.72 25 13.21 1274 6 7
6 95.56 25 13.99 492 6 7
7 25.76 25 14.24 360 6 7
8 0.08 191 14.07 322 6 17

Cycle 63 GMT 6/11/2015 0:13: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.56 26 14.31 446 6 6
2 1019.72 1 10.94 1910 6 6
3 1743.40 50 10.43 2879 6 6
4 1579.28 25 12.11 2694 6 6
5 946.88 25 12.82 1799 6 6
6 285.36 25 13.65 813 6 7
7 72.40 25 14.12 437 6 7
8 0.12 190 14.10 319 6 14

Cycle 62 GMT 26/10/2015 23:37: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.08 26 14.25 464 6 6
2 1819.36 50 10.17 2963 6 6
3 1657.64 25 12.01 2812 6 6
4 1026.88 25 12.75 1924 6 6
5 374.56 25 13.54 944 6 7
6 77.48 25 14.09 444 6 7
7 43.32 25 14.16 388 6 7
8 0.04 191 14.06 320 6 17

Cycle 61 GMT 16/10/2015 22:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.16 26 14.25 446 6 6
2 1753.12 50 10.26 2890 6 6
3 1583.40 25 12.06 2719 6 6
4 1166.12 25 12.58 2142 6 6
5 489.60 25 13.34 1149 6 7
6 111.20 25 13.97 520 6 7
7 25.00 25 14.19 367 6 7
8 0.08 190 14.02 344 6 22

Cycle 60 GMT 6/10/2015 22:26: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.24 26 14.18 482 6 6
2 1895.20 50 10.02 3075 6 6
3 1708.64 25 11.94 2928 6 6
4 949.52 25 12.87 1817 6 6
5 324.84 25 13.60 876 6 7
6 83.04 25 14.06 464 6 7
7 43.52 25 14.18 392 6 7
8 0.04 190 14.07 321 6 16

Cycle 59 GMT 26/ 9/2015 21:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 26 14.25 482 6 6
2 1922.24 50 10.00 3116 6 6
3 1734.68 25 11.98 2935 6 6
4 1312.16 25 12.46 2349 6 6
5 638.08 25 13.21 1362 6 7
6 104.80 25 14.04 498 6 7
7 27.28 25 14.25 358 6 7
8 0.16 190 14.08 322 6 15

Cycle 58 GMT 16/ 9/2015 20:16: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.00 26 14.25 464 6 6
2 2001.52 50 9.77 3176 6 6
3 1823.56 25 11.93 3056 6 6
4 1190.20 25 12.66 2144 6 6
5 745.40 25 13.11 1499 6 7
6 127.04 25 13.96 538 6 7
7 33.12 25 14.22 369 6 7
8 0.12 190 14.04 331 6 15

Cycle 57 GMT 6/ 9/2015 19:42: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.24 26 14.31 464 6 6
2 2005.72 50 9.99 3194 6 6
3 1636.56 25 12.18 2779 6 6
4 1220.12 25 12.63 2190 6 6
5 528.04 25 13.31 1210 6 7
6 92.72 25 14.06 508 6 7
7 47.08 25 14.16 438 6 7
8 0.12 190 14.02 349 6 15

Cycle 56 GMT 27/ 8/2015 19: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.16 26 14.25 464 6 6
2 2007.08 50 9.85 3182 6 6
3 1822.48 25 11.97 3035 6 6
4 1169.68 25 12.69 2142 6 6
5 349.44 25 13.61 913 6 7
6 90.60 25 14.08 469 6 7
7 24.84 25 14.28 349 6 7
8 0.08 191 14.07 316 6 16

Cycle 55 GMT 17/ 8/2015 17:53: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.76 26 14.25 464 6 6
2 2001.76 50 9.63 3503 6 6
3 1833.12 25 12.11 3022 6 6
4 1430.72 25 12.52 2481 6 6
5 766.24 25 13.12 1562 6 7
6 149.32 25 13.93 589 6 7
7 46.32 25 14.21 395 6 7
8 0.60 190 14.05 325 6 15

Cycle 54 GMT 7/ 8/2015 17:24: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.08 27 14.31 446 6 6
2 955.44 -1 14.31 446 6 6
3 2007.12 50 10.06 3186 6 6
4 1816.24 25 12.04 3024 6 6
5 1176.12 25 12.68 2155 6 6
6 364.64 25 13.58 938 6 7
7 82.28 25 14.13 456 6 7
8 44.48 25 14.21 380 6 7
9 0.08 191 14.07 314 6 19

Cycle 53 GMT 28/ 7/2015 16:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.08 25 14.37 446 6 6
2 1054.04 1 12.68 1982 6 6
3 1019.92 1 12.18 1946 6 6
4 2004.92 50 10.08 3187 6 6
5 1823.20 25 12.06 3042 6 6
6 1185.80 25 12.69 2144 6 6
7 528.88 25 13.40 1190 6 7
8 89.16 25 14.08 471 6 7
9 50.80 25 14.20 395 6 7
10 0.00 191 14.12 309 6 17

Cycle 52 GMT 18/ 7/2015 16:15: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.32 28 14.31 446 6 6
2 923.88 -1 14.31 446 6 6
3 970.84 -1 14.31 446 6 6
4 2002.12 50 10.12 3211 6 6
5 1816.84 25 12.07 3015 6 6
6 1153.12 25 12.74 2106 6 6
7 505.12 25 13.42 1167 6 7
8 124.68 25 14.01 540 6 7
9 64.44 25 14.18 426 6 7
10 0.08 190 14.09 319 6 15

Cycle 51 GMT 8/ 7/2015 16: 3: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.20 26 14.37 446 6 6
2 1025.40 3 13.18 1928 6 6
3 945.76 -1 13.18 1928 6 6
4 2004.80 50 10.19 3201 6 6
5 1810.24 25 12.09 3022 6 6
6 979.92 25 12.90 1855 6 6
7 359.88 25 13.64 920 6 7
8 109.00 25 14.03 506 6 7
9 57.88 25 14.21 406 6 7
10 -0.04 191 14.10 309 6 16

Cycle 50 GMT 28/ 6/2015 15: 9: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.00 27 14.37 446 6 6
2 944.32 -1 14.37 446 6 6
3 2002.60 50 10.15 3202 6 6
4 1826.48 25 12.10 3021 6 6
5 1191.16 25 12.72 2158 6 6
6 528.88 25 13.39 1212 6 7
7 97.64 25 14.10 487 6 7
8 60.44 25 14.24 408 6 7
9 0.16 190 14.15 307 6 14

Cycle 49 GMT 18/ 6/2015 14:35: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.12 26 14.37 446 6 6
2 1049.36 1 13.00 1964 6 6
3 2001.68 50 10.19 3203 6 6
4 1621.64 25 12.38 2724 6 6
5 1186.72 25 12.76 2135 6 6
6 329.76 25 13.70 880 6 7
7 87.04 25 14.12 464 6 7
8 44.16 25 14.20 386 6 7
9 0.04 190 14.08 310 6 16

Cycle 48 GMT 8/ 6/2015 13:41: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.28 27 14.37 446 6 6
2 961.36 -1 14.37 446 6 6
3 2001.32 35 10.36 3197 6 6
4 1863.52 20 12.31 3084 6 6
5 1648.64 20 12.49 2811 6 6
6 1026.36 20 13.05 1912 6 6
7 591.60 21 13.40 1285 6 7
8 100.48 21 14.10 484 6 7
9 59.72 21 14.22 408 6 7
10 0.08 190 14.14 306 6 15

Cycle 47 GMT 29/ 5/2015 12:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.12 26 14.37 464 6 6
2 1035.76 1 13.00 1928 6 6
3 2025.00 35 10.51 3245 6 6
4 1859.44 20 12.35 3064 6 6
5 1462.36 20 12.70 2530 6 6
6 839.08 21 13.19 1642 6 6
7 401.00 21 13.66 993 6 7
8 99.08 21 14.11 487 6 7
9 57.92 21 14.23 408 6 7
10 0.08 190 14.14 309 6 16

Cycle 46 GMT 19/ 5/2015 11:45: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 27 14.37 464 6 6
2 964.52 -1 14.37 464 6 6
3 1027.44 1 12.81 1946 6 6
4 2003.64 35 10.65 3219 6 6
5 1839.64 20 12.34 3055 6 6
6 1630.16 20 12.58 2751 6 6
7 983.92 20 13.11 1838 6 6
8 527.20 21 13.51 1188 6 7
9 131.44 21 14.05 553 6 8
10 79.04 21 14.21 442 6 8
11 0.12 190 14.12 309 6 14

Cycle 45 GMT 9/ 5/2015 10:54: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.88 27 14.37 446 6 6
2 2001.68 35 10.67 3246 6 6
3 1820.88 20 12.38 3046 6 6
4 1622.60 20 12.62 2758 6 6
5 955.20 20 13.15 1803 6 7
6 515.92 21 13.54 1170 6 7
7 134.00 21 14.07 553 6 7
8 70.88 21 14.21 432 6 7
9 0.04 190 14.14 310 6 21

Cycle 44 GMT 29/ 4/2015 10:17: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.96 25 14.31 464 6 6
2 1049.16 1 13.25 1964 6 6
3 2002.48 35 10.86 3262 6 6
4 1842.00 20 12.42 3053 6 6
5 1630.64 20 12.63 2780 6 6
6 969.84 20 13.16 1843 6 7
7 505.00 21 13.55 1156 6 7
8 121.08 21 14.06 535 6 7
9 31.52 21 14.27 369 6 7
10 0.12 190 14.09 318 6 15

Cycle 43 GMT 19/ 4/2015 9:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.84 26 14.43 446 6 6
2 970.12 -1 14.43 446 6 6
3 1035.04 1 13.25 1964 6 6
4 2005.00 35 10.90 3560 6 6
5 1862.40 20 12.48 3111 6 6
6 1670.00 20 12.69 2794 6 6
7 1252.48 20 12.95 2247 6 6
8 795.96 21 13.26 1579 6 7
9 143.36 21 14.02 571 6 7
10 77.64 21 14.23 450 6 7
11 0.20 190 14.12 314 6 13

Cycle 42 GMT 9/ 4/2015 9:39: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.12 27 14.43 464 6 6
2 968.40 -1 14.43 464 6 6
3 2001.00 36 11.36 3287 6 6
4 1819.20 20 12.42 3062 6 6
5 1609.20 20 12.66 2756 6 6
6 1142.24 20 13.05 2048 6 6
7 668.00 20 13.44 1416 6 7
8 99.36 20 14.18 482 6 7
9 58.92 20 14.26 410 6 7
10 27.12 20 14.31 352 6 7
11 0.12 191 14.13 308 6 18

Cycle 41 GMT 30/ 3/2015 9:42: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.32 26 14.43 446 6 6
2 1026.24 1 13.18 1928 6 6
3 1019.20 1 12.75 1964 6 6
4 2006.36 36 11.57 3279 6 6
5 1848.20 21 12.40 3096 6 6
6 1413.48 20 12.89 2441 6 6
7 949.04 20 13.24 1778 6 6
8 280.20 20 13.87 812 6 7
9 126.76 20 14.14 541 6 7
10 68.40 20 14.24 428 6 7
11 0.12 190 14.16 314 6 12

Cycle 40 GMT 20/ 3/2015 9:19: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.40 27 14.43 446 6 6
2 971.68 -1 14.43 446 6 6
3 2000.88 35 11.81 3263 6 6
4 1817.72 20 12.56 3039 6 6
5 1610.12 20 12.78 2729 6 6
6 934.56 21 13.19 1789 6 7
7 492.72 21 13.63 1138 6 7
8 111.36 21 14.15 519 6 7
9 55.24 21 14.27 408 6 7
10 0.08 201 14.11 321 6 19

Cycle 39 GMT 10/ 3/2015 9: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.48 25 14.43 446 6 6
2 1038.76 1 13.56 1982 6 6
3 2003.32 36 11.94 3267 6 6
4 1816.56 20 12.55 3060 6 6
5 1615.52 20 12.79 2731 6 6
6 931.88 21 13.23 1795 6 7
7 454.16 21 13.69 1087 6 7
8 119.36 20 14.19 521 6 7
9 57.64 21 14.31 404 6 7
10 -0.04 201 14.15 315 6 18

Cycle 38 GMT 28/ 2/2015 8:49: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.68 26 14.50 464 6 6
2 962.32 -1 14.50 464 6 6
3 1029.64 1 13.25 1964 6 6
4 2005.96 36 12.09 3289 6 6
5 1824.76 20 12.62 3051 6 6
6 1612.36 20 12.74 2782 6 6
7 910.64 21 13.26 1763 6 6
8 225.36 20 13.99 727 6 7
9 116.20 20 14.23 523 6 7
10 65.48 21 14.27 430 6 7
11 0.08 201 14.19 314 6 17

Cycle 37 GMT 18/ 2/2015 8:33: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.12 26 14.43 464 6 6
2 2002.44 36 12.13 3263 6 6
3 1810.72 20 12.59 3059 6 6
4 1596.00 20 12.83 2734 6 6
5 924.48 21 13.27 1783 6 6
6 233.08 20 14.02 736 6 7
7 110.36 21 14.24 517 6 7
8 59.96 21 14.29 426 6 7
9 0.12 201 14.17 322 6 17

Cycle 36 GMT 8/ 2/2015 8:12: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.32 26 14.43 482 6 6
2 1861.84 36 12.28 3111 6 6
3 1687.60 20 12.74 2899 6 6
4 1282.16 21 13.01 2315 6 6
5 832.36 21 13.37 1646 6 7
6 171.60 20 14.12 631 6 7
7 90.24 20 14.26 484 6 7
8 45.40 21 14.33 392 6 7
9 0.12 201 14.14 322 6 20

Cycle 35 GMT 29/ 1/2015 7:27: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 107.40 27 14.43 464 6 6
2 958.60 -1 14.43 464 6 6
3 1801.72 36 12.42 3020 6 6
4 1633.80 20 12.77 2798 6 6
5 1420.08 21 12.92 2507 6 6
6 736.24 21 13.43 1541 6 7
7 255.24 20 13.99 785 6 7
8 69.60 21 14.32 442 6 7
9 38.68 20 14.35 377 6 7
10 0.12 200 14.15 323 6 15

Cycle 34 GMT 19/ 1/2015 6:57: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.00 26 14.50 446 6 6
2 1794.84 36 12.38 2997 6 6
3 1624.76 20 12.83 2758 6 6
4 1415.36 21 12.95 2442 6 6
5 722.20 21 13.49 1479 6 7
6 138.84 20 14.20 562 6 6
7 79.68 21 14.30 454 6 7
8 38.60 20 14.37 375 6 7
9 0.08 201 14.16 321 6 19

Cycle 33 GMT 9/ 1/2015 6:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.80 25 14.56 446 6 6
2 1037.72 1 13.62 1982 6 6
3 1019.76 1 13.62 1946 6 6
4 1833.60 36 12.02 3186 6 6
5 1676.88 21 12.77 2822 6 6
6 1479.00 21 12.93 2527 6 6
7 772.36 21 13.46 1529 6 6
8 311.72 20 14.00 843 6 7
9 92.96 20 14.34 455 6 7
10 51.80 20 14.40 383 6 7
11 0.16 201 14.24 304 6 14

Cycle 32 GMT 30/12/2014 5:49: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.12 26 14.50 464 6 6
2 970.24 -1 14.50 464 6 6
3 1858.52 36 12.34 3074 6 6
4 1691.36 21 12.71 2860 6 6
5 1265.96 21 13.07 2249 6 6
6 819.36 20 13.46 1618 6 7
7 164.16 20 14.16 611 6 7
8 87.60 20 14.31 473 6 7
9 46.48 20 14.37 389 6 7
10 0.72 201 14.17 316 6 19

Cycle 31 GMT 20/12/2014 5: 7: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 106.92 26 14.56 446 6 6
2 1871.64 36 12.33 3083 6 6
3 1694.40 21 12.71 2884 6 6
4 1476.08 21 12.92 2541 6 6
5 780.00 20 13.49 1550 6 7
6 299.72 20 14.00 836 6 7
7 79.48 20 14.37 446 6 7
8 45.96 20 14.37 383 6 7
9 0.08 201 14.23 309 6 19

Cycle 30 GMT 10/12/2014 4:29: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.28 25 14.50 464 6 6
2 1021.52 1 13.75 1946 6 6
3 1027.64 1 13.81 1982 6 6
4 1861.04 36 12.27 3094 6 6
5 1685.36 21 12.72 2832 6 6
6 1466.96 21 12.92 2541 6 6
7 757.92 20 13.52 1535 6 7
8 154.24 20 14.22 593 6 7
9 86.72 20 14.32 466 6 7
10 45.64 20 14.40 389 6 7
11 0.16 201 14.23 308 6 16

Cycle 29 GMT 30/11/2014 3:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.72 26 14.56 446 6 6
2 941.68 -1 14.56 446 6 6
3 1832.64 36 12.32 3070 6 6
4 1668.36 21 12.74 2823 6 6
5 1461.76 21 12.93 2531 6 6
6 802.36 20 13.48 1604 6 7
7 169.08 20 14.20 627 6 7
8 87.24 20 14.34 457 6 7
9 42.92 20 14.42 379 6 7
10 0.16 201 14.23 305 6 18

Cycle 28 GMT 20/11/2014 3:10: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.96 26 14.43 464 6 6
2 1751.44 36 12.44 2926 6 6
3 1591.80 21 12.81 2707 6 6
4 1384.28 21 12.96 2436 6 6
5 668.52 20 13.61 1405 6 7
6 128.88 20 14.27 541 6 6
7 78.36 20 14.38 437 6 7
8 37.00 20 14.44 366 6 7
9 0.16 201 14.21 310 6 20

Cycle 27 GMT 10/11/2014 2:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.72 26 14.56 446 6 6
2 1022.56 1 13.75 1964 6 6
3 1774.36 36 12.14 3146 6 6
4 1623.72 21 12.87 2765 6 6
5 1412.20 21 13.01 2475 6 6
6 743.40 20 13.58 1504 6 7
7 264.00 20 14.09 778 6 7
8 73.72 20 14.41 423 6 7
9 40.36 20 14.44 372 6 7
10 0.20 201 14.23 301 6 17

Cycle 26 GMT 31/10/2014 2:15: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.16 26 14.50 446 6 6
2 1793.60 36 12.36 2985 6 6
3 1627.96 21 12.77 2777 6 6
4 1412.48 21 12.97 2451 6 6
5 708.76 21 13.55 1458 6 7
6 133.52 20 14.29 553 6 6
7 78.80 20 14.37 448 6 7
8 39.16 20 14.41 375 6 7
9 0.08 201 14.22 303 6 20

Cycle 25 GMT 21/10/2014 1:38:59

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.76 25 14.56 446 6 6
2 1867.52 36 12.34 3078 6 6
3 1692.44 21 12.74 2821 6 6
4 1483.20 21 12.94 2531 6 6
5 771.52 21 13.51 1519 6 7
6 152.84 20 14.27 573 6 6
7 85.44 20 14.39 446 6 6
8 40.12 20 14.46 377 6 7
9 0.08 201 14.22 311 6 16

Cycle 24 GMT 11/10/2014 1: 2: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 114.20 26 14.50 446 6 6
2 965.16 -1 14.50 446 6 6
3 1028.36 1 13.68 1964 6 6
4 1922.28 36 12.31 3177 6 6
5 1744.12 20 12.78 2903 6 6
6 1313.88 21 13.04 2332 6 6
7 841.28 21 13.46 1630 6 7
8 180.84 20 14.22 633 6 7
9 103.52 20 14.34 484 6 7
10 49.96 21 14.44 390 6 7
11 2.36 21 14.50 309 6 8
12 0.08 200 14.20 310 6 23

Cycle 23 GMT 1/10/2014 0:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.80 26 14.56 446 6 6
2 1962.76 36 12.30 3233 6 6
3 1779.76 21 12.69 2975 6 6
4 1347.28 21 13.03 2352 6 6
5 670.88 20 13.63 1396 6 6
6 203.92 20 14.17 684 6 7
7 104.00 20 14.34 491 6 7
8 50.20 20 14.42 396 6 7
9 0.08 201 14.18 313 6 18

Cycle 22 GMT 20/ 9/2014 23: 1: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.80 26 14.56 446 6 6
2 1962.48 36 12.35 3210 6 6
3 1769.44 21 12.70 2959 6 6
4 1345.48 21 13.02 2366 6 6
5 883.64 20 13.44 1705 6 6
6 168.84 20 14.21 629 6 7
7 94.96 20 14.35 473 6 7
8 44.64 20 14.44 375 6 7
9 0.12 201 14.21 318 6 16

Cycle 21 GMT 10/ 9/2014 22: 9: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.44 25 14.50 464 6 6
2 1020.92 1 14.06 1910 6 6
3 1750.40 36 12.43 3037 6 6
4 1587.60 21 12.87 2692 6 6
5 1371.24 21 13.03 2380 6 6
6 905.36 21 13.43 1691 6 7
7 192.32 20 14.16 675 6 7
8 106.80 20 14.31 499 6 7
9 54.08 20 14.43 401 6 7
10 0.12 201 14.19 310 6 18

Cycle 20 GMT 31/ 8/2014 21:50: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.84 26 14.50 446 6 6
2 972.00 -1 14.50 446 6 6
3 1020.24 1 13.87 1964 6 6
4 1628.72 36 12.58 2745 6 6
5 1479.68 21 12.83 2571 6 6
6 1272.16 21 12.98 2267 6 6
7 798.00 21 13.44 1583 6 7
8 150.28 20 14.25 575 6 7
9 79.32 20 14.37 448 6 7
10 37.56 20 14.42 374 6 7
11 0.08 201 14.18 311 6 20

Cycle 19 GMT 21/ 8/2014 21:51: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.16 25 14.56 446 6 6
2 1027.56 1 14.12 1964 6 6
3 1853.40 36 12.42 3061 6 6
4 1674.24 21 12.66 2817 6 6
5 1460.56 21 12.85 2533 6 6
6 536.00 20 13.74 1200 6 7
7 162.72 20 14.24 604 6 7
8 90.04 20 14.38 464 6 7
9 41.72 20 14.44 381 6 7
10 0.00 201 14.17 309 6 19

Cycle 18 GMT 11/ 8/2014 21:12: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.36 26 14.50 464 6 6
2 969.56 -1 14.50 464 6 6
3 2001.44 36 12.35 3276 6 6
4 1817.20 21 12.56 3027 6 6
5 1365.80 21 12.94 2412 6 6
6 690.48 20 13.57 1448 6 7
7 153.56 20 14.27 591 6 7
8 88.08 20 14.37 466 6 7
9 18.32 20 14.52 341 6 7
10 0.12 200 14.20 309 6 16

Cycle 17 GMT 1/ 8/2014 20:44: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.84 26 14.56 446 6 6
2 2002.56 36 12.41 3262 6 6
3 1816.52 21 12.57 3009 6 6
4 1359.00 21 12.96 2382 6 6
5 665.96 20 13.60 1394 6 7
6 185.84 20 14.17 666 6 7
7 101.12 20 14.32 500 6 7
8 45.72 20 14.41 392 6 7
9 0.16 201 14.14 318 6 22

Cycle 16 GMT 22/ 7/2014 20:10: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.52 26 14.50 464 6 6
2 2001.72 36 12.41 3279 6 6
3 1816.52 21 12.57 3035 6 6
4 1372.08 21 12.94 2406 6 6
5 701.48 20 13.59 1446 6 7
6 149.92 20 14.28 575 6 7
7 87.56 20 14.40 455 6 7
8 20.28 20 14.55 341 6 7
9 0.12 201 14.21 310 6 17

Cycle 15 GMT 12/ 7/2014 19:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.84 26 14.56 464 6 6
2 2000.88 36 12.42 3284 6 6
3 1818.72 21 12.57 3001 6 6
4 1380.64 21 12.94 2388 6 6
5 700.88 20 13.60 1430 6 6
6 233.24 20 14.11 734 6 7
7 106.64 20 14.30 508 6 7
8 26.52 20 14.48 366 6 7
9 0.12 201 14.14 320 6 17

Cycle 14 GMT 2/ 7/2014 19:11: 2

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.88 26 14.56 446 6 6
2 2001.68 36 12.44 3287 6 6
3 1803.12 21 12.60 3025 6 6
4 1333.68 21 12.98 2354 6 6
5 651.12 20 13.65 1354 6 7
6 190.20 20 14.20 662 6 6
7 95.40 20 14.36 484 6 6
8 45.40 20 14.44 394 6 7
9 0.04 201 14.16 321 6 18

Cycle 13 GMT 22/ 6/2014 18:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.24 26 14.62 446 6 6
2 2004.04 70 12.00 3275 6 6
3 1061.36 24 13.17 1947 6 7
4 371.92 24 13.89 955 6 7
5 93.56 24 14.41 467 6 6
6 19.04 24 14.53 344 6 7
7 0.12 251 14.20 312 6 34

Cycle 12 GMT 12/ 6/2014 18: 6: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 105.56 26 14.62 446 6 6
2 2002.24 70 12.03 3272 6 6
3 1280.44 25 13.00 2285 6 7
4 334.28 24 13.96 887 6 7
5 87.40 24 14.40 469 6 7
6 39.60 24 14.47 378 6 7
7 0.08 251 14.18 309 6 31

Cycle 11 GMT 2/ 6/2014 17:32: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.76 26 14.62 464 6 6
2 2003.64 70 12.07 3256 6 6
3 1086.00 24 13.18 2001 6 6
4 368.68 24 13.92 937 6 7
5 81.68 24 14.42 447 6 7
6 37.44 24 14.48 376 6 7
7 0.12 250 14.18 313 6 32

Cycle 10 GMT 23/ 5/2014 17: 2: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.72 25 14.62 446 6 6
2 2002.88 70 12.11 3276 6 6
3 1042.12 24 13.19 1946 6 7
4 361.20 24 13.92 933 6 7
5 79.68 25 14.44 447 6 7
6 37.68 25 14.47 376 6 7
7 0.12 251 14.18 317 6 33

Cycle 9 GMT 13/ 5/2014 16:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 115.56 25 14.62 464 6 6
2 1984.76 70 11.72 3382 6 6
3 1304.76 24 13.00 2295 6 6
4 610.08 24 13.64 1299 6 7
5 159.72 25 14.24 606 6 7
6 73.28 25 14.42 442 6 7
7 0.08 251 14.21 310 6 32

Cycle 8 GMT 3/ 5/2014 15:45: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 112.80 25 14.62 446 6 6
2 1995.00 70 12.15 3243 6 6
3 1023.16 24 13.20 1905 6 7
4 332.28 24 13.95 897 6 7
5 84.56 24 14.45 453 6 6
6 17.36 24 14.59 337 6 7
7 0.08 251 14.18 309 6 34

Cycle 7 GMT 23/ 4/2014 15: 4: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 111.32 25 14.56 464 6 6
2 2005.56 70 12.14 3272 6 6
3 1039.52 24 13.18 1920 6 7
4 329.76 24 13.94 887 6 7
5 88.84 25 14.46 455 6 7
6 44.16 25 14.52 376 6 7
7 0.08 251 14.22 311 6 38

Cycle 6 GMT 13/ 4/2014 14:10: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.76 22 14.68 446 6 6
2 1007.68 3 14.37 1875 6 6
3 1185.40 70 12.87 2125 6 6
4 740.28 25 13.45 1499 6 6
5 129.08 24 14.35 526 6 7
6 60.40 24 14.47 402 6 7
7 0.16 251 14.23 303 6 32

Cycle 5 GMT 3/ 4/2014 15:33: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.72 29 14.56 446 6 6
2 793.80 -4 14.56 446 6 6
3 940.40 -1 14.56 446 6 6
4 1970.96 70 12.21 3198 6 6
5 816.84 24 13.37 1597 6 7
6 359.04 24 13.92 919 6 7
7 78.04 25 14.45 435 6 7
8 0.08 251 14.20 304 6 29

Cycle 4 GMT 24/ 3/2014 14:54: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 103.20 24 14.62 428 6 6
2 972.80 -1 14.62 428 6 6
3 1508.36 70 12.64 2570 6 6
4 794.24 24 13.36 1585 6 7
5 157.64 24 14.26 581 6 7
6 82.96 24 14.43 442 6 6
7 0.12 251 14.21 303 6 26

Cycle 3 GMT 23/ 3/2014 15:34: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.80 22 14.56 464 6 6
2 1049.88 1 14.25 2000 6 6
3 1506.96 70 12.58 2570 6 6
4 797.52 24 13.33 1581 6 6
5 162.76 24 14.22 594 6 7
6 80.84 24 14.40 449 6 7
7 0.08 251 14.16 315 6 28

Cycle 2 GMT 22/ 3/2014 16: 1: 0

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.80 29 14.50 446 6 6
2 789.00 -4 14.50 446 6 6
3 943.80 -1 14.50 446 6 6
4 1513.36 70 12.48 2584 6 6
5 802.64 25 13.27 1587 6 6
6 163.76 24 14.13 610 6 7
7 83.92 24 14.34 456 6 7
8 0.16 251 14.14 312 6 31

Cycle 1 GMT 21/ 3/2014 16:29: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 109.48 29 14.50 428 7 7
2 784.12 -4 14.50 428 7 7
3 963.60 -1 14.50 428 7 7
4 999.72 70 12.76 1854 7 6
5 106.32 25 14.24 500 6 7
6 8.28 25 14.48 331 6 6
7 0.16 251 14.10 313 6 30

Cycle 0 GMT 21/ 3/2014 4:32: 1

Pump Count Pressure (db) Time (s) Voltage (V) Current (ma) Vacuum0
(load-start)
Vacuum1
(load-stop)
1 119.40 70 14.08 445 6
2 125.16 25 14.44 460 6 7
3 66.12 25 14.55 374 6 6
4 0.20 251 14.42 270 6 22