SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.04 | 38 | 10.75 | 446 | 7 | 7 |
2 | 1028.16 | 50 | 7.53 | 1802 | 6 | 6 |
3 | 855.12 | 40 | 8.24 | 1539 | 6 | 6 |
4 | 252.44 | 41 | 10.06 | 671 | 6 | 6 |
5 | 75.44 | 41 | 10.70 | 367 | 6 | 6 |
6 | 0.24 | 181 | 10.94 | 271 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.36 | 39 | 10.82 | 428 | 7 | 7 |
2 | 1100.16 | 10 | 7.70 | 1910 | 6 | 6 |
3 | 1900.44 | 96 | 5.25 | 3429 | 6 | 6 |
4 | 1900.88 | 50 | 5.18 | 3257 | 6 | 6 |
5 | 1912.28 | 40 | 5.25 | 3388 | 6 | 6 |
6 | 1926.84 | 40 | 5.25 | 3407 | 6 | 6 |
7 | 1919.48 | 40 | 5.25 | 3425 | 6 | 6 |
8 | 1911.40 | 40 | 5.25 | 3433 | 6 | 6 |
9 | 1905.20 | 40 | 5.26 | 3421 | 6 | 6 |
10 | 1899.20 | 40 | 5.31 | 3409 | 6 | 6 |
11 | 1888.20 | 40 | 5.30 | 3429 | 6 | 6 |
12 | 1874.36 | 40 | 5.96 | 3047 | 6 | 6 |
13 | 1799.12 | 40 | 6.02 | 2950 | 6 | 6 |
14 | 1668.32 | 40 | 6.48 | 2709 | 6 | 6 |
15 | 1507.28 | 41 | 6.82 | 2506 | 6 | 6 |
16 | 1145.16 | 41 | 7.69 | 1997 | 6 | 6 |
17 | 742.00 | 41 | 8.76 | 1415 | 6 | 6 |
18 | 167.60 | 41 | 10.44 | 548 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.72 | 40 | 10.88 | 428 | 7 | 7 |
2 | 939.56 | -1 | 10.88 | 428 | 7 | 7 |
3 | 1009.24 | 50 | 7.90 | 1772 | 7 | 6 |
4 | 824.12 | 40 | 8.63 | 1504 | 6 | 6 |
5 | 202.64 | 41 | 10.33 | 582 | 6 | 6 |
6 | 103.44 | 41 | 10.66 | 422 | 6 | 6 |
7 | 0.12 | 181 | 10.94 | 287 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.20 | 39 | 10.82 | 446 | 7 | 7 |
2 | 973.20 | -1 | 10.82 | 446 | 7 | 7 |
3 | 1049.76 | 50 | 7.87 | 1847 | 7 | 6 |
4 | 857.60 | 40 | 8.52 | 1559 | 6 | 6 |
5 | 221.84 | 41 | 10.29 | 624 | 6 | 6 |
6 | 67.92 | 41 | 10.83 | 354 | 6 | 6 |
7 | 0.12 | 180 | 10.96 | 280 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 40 | 10.82 | 446 | 7 | 7 |
2 | 961.64 | -1 | 10.82 | 446 | 7 | 7 |
3 | 1126.12 | 10 | 7.80 | 1963 | 6 | 6 |
4 | 1900.76 | 96 | 6.00 | 3122 | 6 | 6 |
5 | 1897.48 | 50 | 5.19 | 3277 | 6 | 6 |
6 | 1779.48 | 40 | 6.36 | 2845 | 6 | 6 |
7 | 1637.12 | 40 | 6.68 | 2686 | 6 | 6 |
8 | 1453.48 | 40 | 7.10 | 2444 | 6 | 6 |
9 | 856.20 | 41 | 8.60 | 1587 | 6 | 6 |
10 | 246.44 | 41 | 10.19 | 688 | 6 | 6 |
11 | 80.60 | 41 | 10.72 | 408 | 6 | 6 |
12 | 0.80 | 180 | 10.97 | 287 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.48 | 42 | 10.88 | 446 | 7 | 7 |
2 | 922.28 | -2 | 10.88 | 446 | 7 | 7 |
3 | 1030.40 | 50 | 8.09 | 1808 | 6 | 6 |
4 | 831.68 | 40 | 8.75 | 1518 | 6 | 6 |
5 | 198.44 | 41 | 10.42 | 582 | 6 | 6 |
6 | 52.08 | 41 | 10.89 | 326 | 6 | 6 |
7 | 0.12 | 181 | 10.97 | 282 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.04 | 42 | 10.88 | 410 | 7 | 7 |
2 | 900.96 | -2 | 10.88 | 410 | 7 | 7 |
3 | 1008.04 | 50 | 8.34 | 1756 | 7 | 6 |
4 | 809.48 | 40 | 8.85 | 1500 | 6 | 6 |
5 | 188.48 | 40 | 10.48 | 564 | 6 | 6 |
6 | 52.28 | 41 | 10.89 | 325 | 6 | 6 |
7 | 0.84 | 180 | 10.97 | 284 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 34 | 11.07 | 446 | 7 | 7 |
2 | 1000.20 | 4 | 8.57 | 1803 | 6 | 6 |
3 | 1092.04 | 2 | 8.00 | 1892 | 6 | 6 |
4 | 1073.56 | 2 | 8.07 | 1857 | 6 | 6 |
5 | 1040.36 | 50 | 6.89 | 1798 | 6 | 6 |
6 | 880.92 | 40 | 7.76 | 1592 | 6 | 6 |
7 | 460.96 | 40 | 9.16 | 990 | 6 | 6 |
8 | 130.72 | 41 | 10.55 | 458 | 6 | 6 |
9 | 31.32 | 41 | 10.96 | 290 | 6 | 6 |
10 | 0.16 | 181 | 11.02 | 257 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.28 | 29 | 11.44 | 428 | 7 | 7 |
2 | 1002.56 | 5 | 9.69 | 1857 | 6 | 6 |
3 | 1033.84 | 3 | 9.50 | 1875 | 6 | 6 |
4 | 1110.04 | 3 | 9.50 | 1964 | 6 | 6 |
5 | 1069.92 | 2 | 9.44 | 1857 | 6 | 6 |
6 | 1048.12 | 50 | 7.93 | 1828 | 6 | 6 |
7 | 863.72 | 40 | 8.50 | 1551 | 6 | 6 |
8 | 232.04 | 40 | 10.41 | 635 | 6 | 6 |
9 | 73.56 | 41 | 11.02 | 361 | 6 | 6 |
10 | 0.08 | 181 | 11.17 | 266 | 6 | 7 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.96 | 28 | 12.00 | 410 | 6 | 6 |
2 | 1022.04 | 4 | 9.88 | 1821 | 6 | 6 |
3 | 1060.16 | 2 | 9.82 | 1821 | 6 | 6 |
4 | 1039.24 | 1 | 9.63 | 1839 | 6 | 6 |
5 | 1133.56 | 10 | 9.22 | 1946 | 6 | 6 |
6 | 1902.76 | 96 | 5.28 | 2534 | 6 | 7 |
7 | 1901.72 | 50 | 4.80 | 1905 | 7 | 7 |
8 | 1801.44 | 40 | 6.78 | 2950 | 6 | 6 |
9 | 1672.64 | 40 | 7.27 | 2677 | 6 | 6 |
10 | 1502.28 | 40 | 7.76 | 2471 | 6 | 6 |
11 | 1095.32 | 40 | 8.78 | 1903 | 6 | 6 |
12 | 276.28 | 41 | 10.51 | 739 | 6 | 6 |
13 | 86.76 | 41 | 11.07 | 416 | 6 | 6 |
14 | 0.12 | 181 | 11.25 | 292 | 6 | 8 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.68 | 28 | 13.12 | 428 | 6 | 6 |
2 | 1039.28 | 3 | 10.69 | 1892 | 6 | 6 |
3 | 1061.16 | 2 | 11.07 | 1839 | 6 | 6 |
4 | 1029.36 | 1 | 10.88 | 1785 | 6 | 6 |
5 | 1018.48 | 50 | 4.78 | 1515 | 6 | 7 |
6 | 1014.72 | 41 | 6.22 | 1723 | 6 | 7 |
7 | 899.68 | 41 | 7.49 | 1578 | 6 | 6 |
8 | 541.76 | 41 | 9.58 | 1114 | 6 | 6 |
9 | 154.28 | 41 | 11.51 | 516 | 6 | 6 |
10 | 33.16 | 41 | 12.12 | 310 | 6 | 7 |
11 | 0.08 | 181 | 12.00 | 264 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 28 | 14.00 | 464 | 7 | 7 |
2 | 1021.20 | 1 | 11.19 | 1857 | 6 | 6 |
3 | 1015.44 | 50 | 5.61 | 1744 | 6 | 6 |
4 | 900.60 | 40 | 8.14 | 1611 | 6 | 6 |
5 | 701.52 | 40 | 9.35 | 1344 | 6 | 6 |
6 | 132.88 | 41 | 12.35 | 491 | 6 | 7 |
7 | 0.12 | 181 | 12.80 | 277 | 6 | 9 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.08 | 28 | 13.93 | 482 | 6 | 7 |
2 | 1206.60 | 10 | 9.01 | 2602 | 6 | 6 |
3 | 1907.84 | 96 | 5.35 | 2705 | 6 | 6 |
4 | 1908.84 | 50 | 5.68 | 2764 | 6 | 7 |
5 | 1832.64 | 40 | 7.62 | 2951 | 6 | 6 |
6 | 1688.72 | 40 | 7.99 | 2764 | 6 | 6 |
7 | 1306.76 | 40 | 9.27 | 2247 | 6 | 6 |
8 | 701.92 | 40 | 11.04 | 1403 | 6 | 6 |
9 | 126.40 | 40 | 13.29 | 508 | 6 | 7 |
10 | 0.12 | 181 | 13.44 | 319 | 6 | 11 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.04 | 28 | 14.00 | 482 | 6 | 6 |
2 | 1022.60 | 50 | 4.73 | 1333 | 6 | 7 |
3 | 1028.56 | 41 | 7.84 | 1794 | 6 | 6 |
4 | 858.92 | 41 | 9.32 | 1582 | 6 | 6 |
5 | 231.60 | 41 | 12.92 | 682 | 6 | 7 |
6 | 51.56 | 41 | 13.87 | 369 | 6 | 8 |
7 | 0.16 | 181 | 13.83 | 303 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.16 | 28 | 14.18 | 464 | 6 | 7 |
2 | 993.96 | 50 | 5.66 | 1747 | 7 | 6 |
3 | 876.52 | 41 | 9.88 | 1614 | 6 | 6 |
4 | 441.56 | 41 | 12.03 | 1009 | 6 | 6 |
5 | 93.88 | 41 | 13.75 | 434 | 6 | 8 |
6 | 0.04 | 181 | 13.86 | 315 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.48 | 28 | 13.93 | 464 | 6 | 6 |
2 | 1103.16 | 10 | 10.25 | 1953 | 6 | 6 |
3 | 1855.36 | 96 | 5.73 | 3006 | 6 | 6 |
4 | 1851.72 | 50 | 7.06 | 3013 | 6 | 6 |
5 | 1683.92 | 40 | 8.86 | 2789 | 6 | 6 |
6 | 1051.88 | 40 | 11.31 | 1883 | 6 | 6 |
7 | 186.84 | 41 | 13.65 | 619 | 6 | 7 |
8 | 41.20 | 41 | 14.16 | 367 | 6 | 8 |
9 | 0.12 | 180 | 14.07 | 316 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 28 | 14.06 | 464 | 6 | 6 |
2 | 1008.04 | 50 | 4.79 | 1560 | 6 | 7 |
3 | 1007.32 | 41 | 9.49 | 1793 | 6 | 6 |
4 | 831.00 | 41 | 10.46 | 1551 | 6 | 6 |
5 | 170.24 | 41 | 13.41 | 581 | 6 | 7 |
6 | 2.68 | 41 | 14.19 | 289 | 6 | 8 |
7 | 0.12 | 180 | 14.01 | 310 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.12 | 28 | 14.18 | 464 | 6 | 7 |
2 | 1019.76 | 1 | 10.57 | 1839 | 6 | 6 |
3 | 1013.52 | 50 | 6.40 | 1767 | 6 | 6 |
4 | 875.20 | 40 | 10.56 | 1621 | 6 | 6 |
5 | 251.40 | 40 | 13.16 | 710 | 6 | 7 |
6 | 56.76 | 41 | 14.00 | 376 | 6 | 8 |
7 | 0.08 | 181 | 14.08 | 311 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.44 | 28 | 14.06 | 482 | 6 | 6 |
2 | 1115.64 | 10 | 10.31 | 1986 | 6 | 6 |
3 | 1853.56 | 96 | 6.08 | 3113 | 6 | 6 |
4 | 1847.60 | 50 | 7.88 | 3019 | 6 | 6 |
5 | 1438.80 | 40 | 10.62 | 2456 | 6 | 6 |
6 | 731.64 | 40 | 12.37 | 1460 | 6 | 7 |
7 | 119.00 | 40 | 13.96 | 495 | 6 | 8 |
8 | 0.08 | 181 | 14.18 | 318 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.48 | 29 | 14.12 | 464 | 6 | 6 |
2 | 976.28 | -1 | 14.12 | 464 | 6 | 6 |
3 | 1025.92 | 50 | 4.81 | 1643 | 6 | 7 |
4 | 1018.64 | 41 | 9.73 | 1814 | 6 | 6 |
5 | 848.80 | 41 | 10.81 | 1572 | 6 | 6 |
6 | 179.32 | 41 | 13.55 | 594 | 6 | 7 |
7 | 0.80 | 180 | 14.12 | 316 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.12 | 28 | 14.12 | 464 | 6 | 6 |
2 | 976.40 | -1 | 14.12 | 464 | 6 | 6 |
3 | 1022.28 | 1 | 10.32 | 1803 | 6 | 6 |
4 | 1021.88 | 50 | 6.96 | 1761 | 6 | 6 |
5 | 854.72 | 40 | 10.96 | 1590 | 6 | 6 |
6 | 192.20 | 40 | 13.50 | 616 | 6 | 7 |
7 | 43.00 | 41 | 14.07 | 357 | 6 | 8 |
8 | 0.00 | 181 | 14.10 | 317 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.20 | 28 | 14.12 | 464 | 6 | 6 |
2 | 1107.64 | 10 | 10.37 | 1964 | 6 | 6 |
3 | 1890.04 | 96 | 6.74 | 2991 | 6 | 6 |
4 | 1884.84 | 50 | 7.87 | 3045 | 6 | 6 |
5 | 1243.92 | 40 | 11.28 | 2168 | 6 | 6 |
6 | 332.56 | 40 | 13.41 | 863 | 6 | 8 |
7 | 59.20 | 40 | 14.12 | 406 | 6 | 8 |
8 | 0.08 | 181 | 14.19 | 319 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 28 | 14.12 | 464 | 6 | 6 |
2 | 1045.92 | 1 | 10.57 | 1875 | 6 | 6 |
3 | 1020.36 | 50 | 4.82 | 1671 | 6 | 7 |
4 | 1020.04 | 40 | 9.64 | 1807 | 6 | 6 |
5 | 844.20 | 40 | 10.87 | 1578 | 6 | 6 |
6 | 171.12 | 41 | 13.66 | 581 | 6 | 7 |
7 | 0.00 | 181 | 14.16 | 307 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.92 | 28 | 14.18 | 464 | 7 | 7 |
2 | 996.28 | 50 | 7.22 | 1738 | 7 | 6 |
3 | 826.12 | 40 | 11.11 | 1550 | 6 | 6 |
4 | 180.84 | 40 | 13.57 | 595 | 6 | 7 |
5 | 0.16 | 181 | 14.16 | 315 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.52 | 28 | 14.12 | 464 | 6 | 7 |
2 | 1215.68 | 10 | 9.84 | 2599 | 6 | 6 |
3 | 1901.24 | 96 | 6.49 | 3127 | 6 | 6 |
4 | 1897.48 | 50 | 8.25 | 3072 | 6 | 6 |
5 | 1469.24 | 40 | 10.89 | 2499 | 6 | 6 |
6 | 567.72 | 40 | 12.93 | 1227 | 6 | 7 |
7 | 74.20 | 40 | 14.10 | 429 | 6 | 8 |
8 | 0.12 | 181 | 14.25 | 329 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.16 | 28 | 14.12 | 464 | 6 | 6 |
2 | 992.16 | 50 | 5.20 | 1657 | 6 | 6 |
3 | 907.24 | 40 | 10.20 | 1655 | 6 | 6 |
4 | 511.44 | 40 | 12.35 | 1113 | 6 | 6 |
5 | 71.92 | 41 | 14.00 | 421 | 6 | 7 |
6 | 0.00 | 180 | 14.18 | 323 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.08 | 28 | 14.18 | 464 | 7 | 7 |
2 | 982.32 | 50 | 7.44 | 1742 | 7 | 6 |
3 | 814.92 | 40 | 11.40 | 1536 | 6 | 6 |
4 | 166.56 | 40 | 13.69 | 563 | 6 | 7 |
5 | 0.04 | 181 | 14.17 | 320 | 6 | 10 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.64 | 28 | 14.06 | 482 | 6 | 7 |
2 | 1103.88 | 10 | 10.25 | 1971 | 6 | 6 |
3 | 1874.40 | 96 | 7.25 | 3000 | 6 | 6 |
4 | 1868.64 | 50 | 8.62 | 3008 | 6 | 6 |
5 | 982.16 | 40 | 12.14 | 1814 | 6 | 6 |
6 | 145.64 | 40 | 13.96 | 550 | 6 | 7 |
7 | 0.12 | 181 | 14.27 | 321 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 28 | 14.18 | 464 | 7 | 7 |
2 | 1013.44 | 50 | 5.14 | 1736 | 7 | 6 |
3 | 954.60 | 40 | 10.49 | 1724 | 6 | 6 |
4 | 567.04 | 40 | 12.38 | 1203 | 6 | 6 |
5 | 86.16 | 41 | 14.02 | 428 | 6 | 7 |
6 | 0.04 | 181 | 14.22 | 320 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.36 | 28 | 14.18 | 464 | 7 | 7 |
2 | 1007.72 | 50 | 7.59 | 1759 | 7 | 6 |
3 | 843.60 | 40 | 11.53 | 1590 | 6 | 6 |
4 | 178.68 | 41 | 13.72 | 587 | 6 | 7 |
5 | 17.32 | 41 | 14.18 | 314 | 6 | 8 |
6 | 0.12 | 181 | 14.22 | 323 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.44 | 28 | 14.12 | 464 | 7 | 7 |
2 | 1127.96 | 10 | 10.42 | 1978 | 6 | 6 |
3 | 1892.76 | 96 | 7.53 | 3029 | 6 | 6 |
4 | 1886.28 | 50 | 8.87 | 3059 | 6 | 6 |
5 | 758.60 | 40 | 12.66 | 1506 | 6 | 7 |
6 | 145.68 | 40 | 13.95 | 545 | 6 | 8 |
7 | 0.04 | 180 | 14.30 | 319 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 28 | 14.12 | 482 | 7 | 7 |
2 | 1002.48 | 50 | 5.14 | 1684 | 7 | 6 |
3 | 957.60 | 40 | 10.69 | 1735 | 6 | 6 |
4 | 557.64 | 41 | 12.56 | 1183 | 6 | 7 |
5 | 87.80 | 41 | 14.04 | 421 | 6 | 7 |
6 | 0.12 | 181 | 14.25 | 316 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 28 | 14.18 | 482 | 7 | 7 |
2 | 1010.96 | 50 | 7.53 | 1769 | 6 | 6 |
3 | 850.16 | 40 | 11.76 | 1599 | 6 | 6 |
4 | 193.24 | 40 | 13.73 | 609 | 6 | 7 |
5 | 33.92 | 41 | 14.17 | 336 | 6 | 8 |
6 | 0.00 | 181 | 14.24 | 317 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.80 | 28 | 14.06 | 464 | 6 | 7 |
2 | 966.92 | -1 | 14.06 | 464 | 6 | 7 |
3 | 1022.28 | 1 | 8.25 | 1803 | 6 | 6 |
4 | 1123.40 | 10 | 10.39 | 1989 | 6 | 6 |
5 | 1873.20 | 96 | 7.78 | 3016 | 6 | 6 |
6 | 1866.88 | 50 | 9.02 | 3040 | 6 | 6 |
7 | 716.56 | 40 | 12.74 | 1449 | 6 | 7 |
8 | 124.80 | 40 | 14.01 | 503 | 6 | 7 |
9 | 0.16 | 181 | 14.31 | 317 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.16 | 28 | 14.12 | 464 | 7 | 7 |
2 | 1002.32 | 50 | 5.52 | 1624 | 7 | 6 |
3 | 913.88 | 40 | 11.17 | 1689 | 6 | 6 |
4 | 496.88 | 41 | 12.83 | 1101 | 6 | 7 |
5 | 103.52 | 41 | 13.97 | 467 | 6 | 8 |
6 | 0.12 | 181 | 14.21 | 328 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.80 | 28 | 14.18 | 464 | 7 | 7 |
2 | 1005.48 | 50 | 7.92 | 1784 | 7 | 6 |
3 | 832.12 | 40 | 11.98 | 1580 | 6 | 6 |
4 | 170.52 | 41 | 13.81 | 571 | 6 | 7 |
5 | 12.88 | 41 | 14.17 | 324 | 6 | 8 |
6 | 0.04 | 181 | 14.24 | 324 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.80 | 27 | 14.12 | 464 | 6 | 6 |
2 | 1035.48 | 1 | 10.07 | 1821 | 6 | 6 |
3 | 1126.04 | 10 | 10.55 | 1971 | 6 | 6 |
4 | 1890.76 | 96 | 8.10 | 3024 | 6 | 6 |
5 | 1883.52 | 50 | 9.30 | 3072 | 6 | 6 |
6 | 513.48 | 40 | 13.17 | 1147 | 6 | 7 |
7 | 126.16 | 40 | 13.99 | 517 | 6 | 8 |
8 | 0.12 | 181 | 14.28 | 328 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.68 | 28 | 14.18 | 482 | 6 | 6 |
2 | 999.00 | 50 | 5.48 | 1616 | 6 | 6 |
3 | 921.72 | 40 | 11.44 | 1699 | 6 | 6 |
4 | 503.56 | 40 | 12.93 | 1111 | 6 | 7 |
5 | 108.48 | 41 | 13.98 | 465 | 6 | 8 |
6 | 0.12 | 181 | 14.22 | 315 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.04 | 28 | 14.12 | 464 | 7 | 7 |
2 | 995.68 | 50 | 7.99 | 1764 | 6 | 6 |
3 | 817.96 | 40 | 12.25 | 1562 | 6 | 6 |
4 | 161.80 | 41 | 13.85 | 565 | 6 | 7 |
5 | 13.04 | 41 | 14.20 | 303 | 6 | 8 |
6 | 0.08 | 181 | 14.21 | 319 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.96 | 28 | 14.00 | 482 | 6 | 6 |
2 | 970.60 | -1 | 14.00 | 482 | 6 | 6 |
3 | 1151.48 | 10 | 10.27 | 2053 | 6 | 6 |
4 | 1735.52 | 96 | 8.57 | 2845 | 6 | 6 |
5 | 1729.20 | 50 | 9.59 | 2843 | 6 | 6 |
6 | 289.44 | 40 | 13.59 | 815 | 6 | 7 |
7 | 62.00 | 40 | 14.11 | 420 | 6 | 8 |
8 | 0.16 | 180 | 14.27 | 329 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.72 | 27 | 14.25 | 464 | 7 | 7 |
2 | 1003.44 | 50 | 5.50 | 1617 | 6 | 6 |
3 | 923.12 | 40 | 11.59 | 1713 | 6 | 6 |
4 | 728.64 | 40 | 12.37 | 1439 | 6 | 6 |
5 | 86.40 | 41 | 13.99 | 438 | 6 | 8 |
6 | 0.16 | 181 | 14.20 | 320 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.44 | 28 | 14.18 | 464 | 6 | 7 |
2 | 1009.04 | 50 | 8.04 | 1765 | 7 | 6 |
3 | 838.52 | 40 | 12.25 | 1594 | 6 | 6 |
4 | 114.40 | 40 | 13.97 | 479 | 6 | 7 |
5 | 8.36 | 41 | 14.17 | 319 | 6 | 8 |
6 | 0.08 | 181 | 14.24 | 323 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.68 | 28 | 14.18 | 464 | 6 | 7 |
2 | 1127.72 | 10 | 10.51 | 2035 | 6 | 6 |
3 | 1879.36 | 96 | 8.55 | 3054 | 6 | 6 |
4 | 1875.20 | 50 | 9.55 | 3070 | 6 | 6 |
5 | 471.20 | 40 | 13.26 | 1088 | 6 | 7 |
6 | 99.68 | 40 | 14.01 | 477 | 6 | 8 |
7 | 0.16 | 181 | 14.25 | 330 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 28 | 14.18 | 464 | 6 | 7 |
2 | 971.12 | -1 | 14.18 | 464 | 6 | 7 |
3 | 1024.32 | 1 | 9.00 | 1821 | 6 | 6 |
4 | 1023.36 | 50 | 5.00 | 1688 | 6 | 6 |
5 | 1001.40 | 40 | 11.64 | 1828 | 6 | 6 |
6 | 592.88 | 40 | 12.85 | 1256 | 6 | 7 |
7 | 89.04 | 41 | 14.06 | 428 | 6 | 7 |
8 | 0.08 | 180 | 14.26 | 293 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 27 | 14.18 | 482 | 7 | 7 |
2 | 1011.80 | 50 | 7.82 | 1761 | 6 | 6 |
3 | 836.44 | 40 | 12.30 | 1605 | 6 | 6 |
4 | 159.20 | 41 | 13.88 | 557 | 6 | 7 |
5 | 14.92 | 41 | 14.19 | 312 | 6 | 8 |
6 | 0.08 | 181 | 14.21 | 317 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.72 | 28 | 14.12 | 464 | 6 | 7 |
2 | 963.28 | -1 | 14.12 | 464 | 6 | 7 |
3 | 1110.60 | 10 | 10.77 | 1978 | 6 | 6 |
4 | 1878.36 | 96 | 8.60 | 3036 | 6 | 6 |
5 | 1869.64 | 50 | 9.62 | 3047 | 6 | 6 |
6 | 414.28 | 40 | 13.38 | 1007 | 6 | 8 |
7 | 84.28 | 40 | 14.04 | 453 | 6 | 7 |
8 | 0.04 | 181 | 14.25 | 328 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 28 | 14.25 | 464 | 6 | 6 |
2 | 995.08 | 50 | 5.36 | 1575 | 6 | 6 |
3 | 918.24 | 40 | 11.81 | 1706 | 6 | 6 |
4 | 501.56 | 40 | 13.06 | 1115 | 6 | 7 |
5 | 67.08 | 41 | 14.07 | 396 | 6 | 7 |
6 | 0.08 | 181 | 14.22 | 310 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.64 | 27 | 14.25 | 464 | 7 | 7 |
2 | 988.56 | 50 | 7.77 | 1742 | 7 | 6 |
3 | 807.72 | 41 | 12.45 | 1562 | 6 | 6 |
4 | 153.36 | 41 | 13.89 | 551 | 6 | 7 |
5 | 15.16 | 41 | 14.17 | 308 | 6 | 8 |
6 | 0.04 | 181 | 14.19 | 323 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.84 | 28 | 14.12 | 464 | 7 | 7 |
2 | 1023.28 | 1 | 8.13 | 1803 | 6 | 6 |
3 | 1134.92 | 10 | 10.71 | 2013 | 6 | 6 |
4 | 1880.56 | 96 | 8.77 | 3049 | 6 | 6 |
5 | 1872.44 | 50 | 9.70 | 3062 | 6 | 6 |
6 | 597.24 | 40 | 13.07 | 1281 | 6 | 8 |
7 | 81.36 | 40 | 14.10 | 434 | 6 | 7 |
8 | 0.12 | 180 | 14.29 | 323 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.04 | 28 | 14.18 | 482 | 7 | 7 |
2 | 1030.96 | 50 | 5.40 | 1625 | 6 | 6 |
3 | 964.24 | 40 | 11.84 | 1764 | 6 | 6 |
4 | 541.08 | 41 | 13.01 | 1178 | 6 | 7 |
5 | 69.80 | 41 | 14.06 | 402 | 6 | 7 |
6 | 0.00 | 181 | 14.21 | 314 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.16 | 27 | 14.18 | 464 | 6 | 6 |
2 | 1016.48 | 50 | 7.71 | 1758 | 6 | 6 |
3 | 834.92 | 40 | 12.43 | 1605 | 6 | 6 |
4 | 166.56 | 40 | 13.83 | 574 | 6 | 7 |
5 | -0.04 | 181 | 14.20 | 315 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.52 | 27 | 14.12 | 464 | 6 | 6 |
2 | 1019.16 | 1 | 9.19 | 1839 | 6 | 6 |
3 | 1109.12 | 10 | 10.80 | 1996 | 6 | 6 |
4 | 1868.72 | 96 | 8.91 | 3014 | 6 | 6 |
5 | 1861.52 | 50 | 9.72 | 3019 | 6 | 6 |
6 | 344.44 | 40 | 13.52 | 893 | 6 | 8 |
7 | 58.32 | 40 | 14.09 | 410 | 6 | 8 |
8 | 0.12 | 181 | 14.23 | 330 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 28 | 14.12 | 482 | 6 | 7 |
2 | 998.48 | 50 | 5.74 | 1663 | 7 | 6 |
3 | 907.32 | 40 | 12.09 | 1698 | 6 | 6 |
4 | 726.76 | 40 | 12.66 | 1442 | 6 | 7 |
5 | 59.80 | 41 | 14.03 | 393 | 6 | 8 |
6 | 0.16 | 181 | 14.15 | 313 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.28 | 27 | 14.12 | 464 | 7 | 6 |
2 | 1013.80 | 50 | 7.62 | 1722 | 6 | 6 |
3 | 857.00 | 40 | 12.44 | 1621 | 6 | 6 |
4 | 167.64 | 40 | 13.83 | 583 | 6 | 7 |
5 | 5.20 | 41 | 14.21 | 295 | 6 | 8 |
6 | 0.08 | 180 | 14.25 | 292 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.04 | 27 | 14.18 | 428 | 7 | 6 |
2 | 1122.52 | 10 | 10.84 | 1999 | 6 | 6 |
3 | 1874.12 | 96 | 9.01 | 3039 | 6 | 6 |
4 | 1865.08 | 50 | 9.71 | 3045 | 6 | 6 |
5 | 326.00 | 40 | 13.53 | 865 | 6 | 8 |
6 | 69.64 | 41 | 14.07 | 411 | 6 | 8 |
7 | 0.28 | 181 | 14.26 | 315 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.40 | 27 | 14.18 | 446 | 7 | 7 |
2 | 1019.80 | 1 | 9.63 | 1857 | 6 | 6 |
3 | 1022.16 | 50 | 6.01 | 1634 | 6 | 6 |
4 | 902.48 | 40 | 12.16 | 1700 | 6 | 6 |
5 | 255.52 | 41 | 13.64 | 728 | 6 | 7 |
6 | 50.84 | 41 | 14.06 | 375 | 6 | 8 |
7 | 0.04 | 181 | 14.24 | 286 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.16 | 27 | 14.25 | 446 | 7 | 7 |
2 | 1002.20 | 50 | 7.98 | 1747 | 7 | 6 |
3 | 831.52 | 40 | 12.50 | 1593 | 6 | 6 |
4 | 174.28 | 41 | 13.84 | 582 | 6 | 7 |
5 | 0.08 | 181 | 14.24 | 297 | 6 | 13 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.08 | 29 | 14.18 | 446 | 7 | 7 |
2 | 924.00 | -2 | 14.18 | 446 | 7 | 7 |
3 | 1117.64 | 10 | 12.18 | 2045 | 6 | 6 |
4 | 1868.28 | 96 | 9.23 | 3034 | 6 | 6 |
5 | 1861.92 | 50 | 9.84 | 3034 | 6 | 6 |
6 | 307.96 | 40 | 13.58 | 835 | 6 | 8 |
7 | 70.68 | 41 | 14.09 | 413 | 6 | 7 |
8 | 0.12 | 181 | 14.24 | 323 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.68 | 29 | 14.12 | 464 | 7 | 7 |
2 | 905.28 | -2 | 14.12 | 464 | 7 | 7 |
3 | 1003.96 | 50 | 6.55 | 1715 | 6 | 6 |
4 | 875.24 | 40 | 12.36 | 1662 | 6 | 6 |
5 | 223.16 | 40 | 13.73 | 673 | 6 | 8 |
6 | 51.72 | 41 | 14.10 | 368 | 6 | 7 |
7 | 0.08 | 181 | 14.24 | 291 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.56 | 27 | 14.12 | 464 | 6 | 7 |
2 | 963.72 | -1 | 14.12 | 464 | 6 | 7 |
3 | 1020.16 | 1 | 10.63 | 1892 | 6 | 6 |
4 | 1032.96 | 50 | 7.88 | 1823 | 6 | 6 |
5 | 861.28 | 40 | 12.58 | 1641 | 6 | 6 |
6 | 111.48 | 41 | 13.99 | 474 | 6 | 7 |
7 | 7.80 | 41 | 14.19 | 306 | 6 | 8 |
8 | 0.16 | 181 | 14.25 | 303 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.04 | 27 | 14.06 | 482 | 6 | 6 |
2 | 1053.88 | 1 | 11.57 | 1892 | 6 | 6 |
3 | 1023.36 | 1 | 10.38 | 1892 | 6 | 6 |
4 | 1122.00 | 10 | 11.58 | 2035 | 6 | 6 |
5 | 1834.84 | 96 | 9.74 | 2995 | 6 | 6 |
6 | 1824.96 | 50 | 10.04 | 2973 | 6 | 6 |
7 | 191.16 | 40 | 13.78 | 644 | 6 | 7 |
8 | 42.84 | 40 | 14.10 | 384 | 6 | 8 |
9 | 0.12 | 181 | 14.20 | 328 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 14 | 14.18 | 446 | 6 | 7 |
2 | 1062.44 | 5 | 12.12 | 1946 | 6 | 6 |
3 | 1109.00 | 3 | 12.56 | 1982 | 6 | 6 |
4 | 1289.64 | 7 | 11.82 | 2196 | 6 | 6 |
5 | 1132.24 | 51 | 10.74 | 1995 | 6 | 6 |
6 | 508.28 | 41 | 13.18 | 1143 | 6 | 7 |
7 | 70.48 | 41 | 14.00 | 431 | 6 | 8 |
8 | 0.08 | 181 | 14.17 | 333 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.24 | 27 | 14.12 | 464 | 7 | 7 |
2 | 1012.88 | 50 | 8.03 | 1769 | 6 | 6 |
3 | 820.24 | 40 | 12.57 | 1587 | 6 | 6 |
4 | 111.84 | 41 | 13.96 | 482 | 6 | 7 |
5 | 0.20 | 181 | 14.22 | 312 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.52 | 28 | 14.06 | 482 | 7 | 6 |
2 | 969.80 | -1 | 14.06 | 482 | 7 | 6 |
3 | 1117.16 | 10 | 11.54 | 2038 | 6 | 6 |
4 | 1766.40 | 96 | 9.74 | 2895 | 6 | 6 |
5 | 1757.80 | 50 | 10.01 | 2893 | 6 | 6 |
6 | 175.08 | 40 | 13.83 | 617 | 6 | 7 |
7 | 2.68 | 40 | 14.17 | 334 | 6 | 7 |
8 | 0.04 | 180 | 14.20 | 335 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 27 | 14.00 | 482 | 6 | 6 |
2 | 761.04 | -5 | 14.00 | 482 | 6 | 6 |
3 | 748.28 | -6 | 14.00 | 482 | 6 | 6 |
4 | 1467.12 | 51 | 9.29 | 2484 | 6 | 6 |
5 | 1277.60 | 41 | 11.82 | 2209 | 6 | 6 |
6 | 195.16 | 41 | 13.76 | 642 | 6 | 7 |
7 | 40.64 | 41 | 14.07 | 390 | 6 | 8 |
8 | 0.08 | 180 | 14.16 | 336 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 27 | 14.12 | 464 | 7 | 7 |
2 | 1003.60 | 50 | 7.27 | 1739 | 7 | 6 |
3 | 836.96 | 40 | 12.44 | 1601 | 6 | 6 |
4 | 171.40 | 41 | 13.77 | 596 | 6 | 7 |
5 | 1.72 | 41 | 14.19 | 303 | 6 | 9 |
6 | 0.08 | 180 | 14.17 | 320 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.72 | 27 | 14.12 | 464 | 6 | 7 |
2 | 1024.92 | 1 | 10.75 | 1857 | 6 | 6 |
3 | 1116.60 | 10 | 11.26 | 1996 | 6 | 6 |
4 | 1774.28 | 96 | 9.20 | 2882 | 6 | 6 |
5 | 1766.84 | 50 | 9.81 | 2889 | 6 | 6 |
6 | 237.96 | 40 | 13.66 | 728 | 6 | 7 |
7 | 23.76 | 40 | 14.11 | 366 | 6 | 8 |
8 | 0.12 | 181 | 14.19 | 334 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.60 | 27 | 14.06 | 482 | 6 | 6 |
2 | 1012.08 | 50 | 6.03 | 1763 | 6 | 6 |
3 | 902.44 | 40 | 12.04 | 1703 | 6 | 6 |
4 | 236.12 | 40 | 13.59 | 715 | 6 | 8 |
5 | 46.60 | 41 | 14.02 | 380 | 6 | 8 |
6 | 0.04 | 181 | 14.13 | 323 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.16 | 27 | 14.12 | 464 | 6 | 6 |
2 | 1018.24 | 50 | 7.11 | 1764 | 6 | 6 |
3 | 869.48 | 40 | 12.33 | 1658 | 6 | 6 |
4 | 179.88 | 40 | 13.76 | 610 | 6 | 7 |
5 | 13.76 | 41 | 14.13 | 323 | 6 | 8 |
6 | 0.04 | 181 | 14.13 | 331 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.40 | 27 | 13.87 | 482 | 6 | 6 |
2 | 1103.60 | 10 | 11.09 | 1995 | 6 | 6 |
3 | 1799.80 | 96 | 9.02 | 2968 | 6 | 6 |
4 | 1792.56 | 50 | 9.77 | 2927 | 6 | 6 |
5 | 279.80 | 40 | 13.57 | 791 | 6 | 8 |
6 | 24.28 | 40 | 14.12 | 355 | 6 | 8 |
7 | 0.04 | 180 | 14.16 | 337 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.80 | 29 | 14.12 | 464 | 6 | 6 |
2 | 924.12 | -2 | 14.12 | 464 | 6 | 6 |
3 | 1020.96 | 50 | 6.49 | 1751 | 6 | 6 |
4 | 866.56 | 40 | 12.15 | 1640 | 6 | 6 |
5 | 201.88 | 40 | 13.66 | 649 | 6 | 7 |
6 | 15.24 | 41 | 14.09 | 334 | 6 | 8 |
7 | 0.00 | 181 | 14.09 | 319 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.60 | 28 | 14.12 | 482 | 6 | 6 |
2 | 970.24 | -1 | 14.12 | 482 | 6 | 6 |
3 | 1025.56 | 1 | 10.88 | 1875 | 6 | 6 |
4 | 1022.48 | 50 | 7.04 | 1763 | 6 | 6 |
5 | 853.20 | 40 | 12.30 | 1640 | 6 | 6 |
6 | 116.64 | 41 | 13.88 | 503 | 6 | 7 |
7 | 23.72 | 41 | 14.09 | 342 | 6 | 8 |
8 | 0.04 | 181 | 14.19 | 304 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.04 | 27 | 14.00 | 464 | 6 | 6 |
2 | 1102.92 | 10 | 11.17 | 1985 | 6 | 6 |
3 | 1814.88 | 96 | 9.00 | 2946 | 6 | 6 |
4 | 1806.84 | 50 | 9.70 | 2958 | 6 | 6 |
5 | 265.92 | 40 | 13.60 | 772 | 6 | 8 |
6 | 57.00 | 40 | 14.02 | 412 | 6 | 8 |
7 | 0.08 | 181 | 14.16 | 337 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.00 | 27 | 14.00 | 482 | 6 | 6 |
2 | 1045.24 | 1 | 10.88 | 1946 | 6 | 6 |
3 | 1030.04 | 1 | 10.82 | 1892 | 6 | 6 |
4 | 1016.28 | 50 | 6.14 | 1731 | 6 | 6 |
5 | 890.92 | 40 | 12.00 | 1689 | 6 | 6 |
6 | 228.00 | 41 | 13.57 | 703 | 6 | 7 |
7 | 46.84 | 41 | 14.00 | 385 | 6 | 8 |
8 | 0.04 | 181 | 14.14 | 304 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.84 | 28 | 14.12 | 482 | 6 | 6 |
2 | 995.36 | 50 | 7.13 | 1732 | 6 | 6 |
3 | 855.40 | 40 | 12.23 | 1637 | 6 | 6 |
4 | 176.08 | 40 | 13.75 | 610 | 6 | 7 |
5 | 0.08 | 180 | 14.16 | 323 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.80 | 27 | 14.00 | 482 | 6 | 6 |
2 | 1113.64 | 10 | 11.10 | 1986 | 6 | 6 |
3 | 1850.32 | 96 | 8.81 | 3004 | 6 | 6 |
4 | 1842.12 | 50 | 9.68 | 3018 | 6 | 6 |
5 | 352.32 | 40 | 13.42 | 912 | 6 | 7 |
6 | 70.44 | 40 | 14.02 | 433 | 6 | 8 |
7 | -0.08 | 181 | 14.19 | 337 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.16 | 27 | 14.00 | 464 | 6 | 6 |
2 | 1011.84 | 50 | 6.54 | 1748 | 6 | 6 |
3 | 876.40 | 40 | 12.01 | 1654 | 6 | 6 |
4 | 202.08 | 40 | 13.66 | 648 | 6 | 8 |
5 | 42.52 | 41 | 14.04 | 363 | 6 | 8 |
6 | 0.08 | 181 | 14.13 | 322 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.84 | 27 | 14.12 | 482 | 7 | 7 |
2 | 1005.40 | 50 | 7.21 | 1742 | 6 | 6 |
3 | 826.96 | 40 | 12.35 | 1590 | 6 | 6 |
4 | 104.76 | 41 | 13.87 | 484 | 6 | 7 |
5 | 53.00 | 41 | 14.04 | 386 | 6 | 8 |
6 | 0.04 | 181 | 14.18 | 305 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.48 | 29 | 13.93 | 482 | 6 | 7 |
2 | 951.08 | -1 | 13.93 | 482 | 6 | 7 |
3 | 976.52 | -1 | 13.93 | 482 | 6 | 7 |
4 | 1132.04 | 10 | 11.17 | 2035 | 6 | 6 |
5 | 1845.68 | 96 | 8.93 | 2974 | 6 | 6 |
6 | 1837.32 | 50 | 9.70 | 3005 | 6 | 6 |
7 | 353.76 | 40 | 13.44 | 912 | 6 | 8 |
8 | 72.40 | 41 | 14.00 | 444 | 6 | 8 |
9 | 0.08 | 181 | 14.20 | 335 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.92 | 29 | 14.06 | 482 | 6 | 6 |
2 | 909.56 | -2 | 14.06 | 482 | 6 | 6 |
3 | 1003.32 | 50 | 6.56 | 1782 | 6 | 6 |
4 | 848.24 | 40 | 12.07 | 1621 | 6 | 6 |
5 | 198.16 | 40 | 13.67 | 646 | 6 | 8 |
6 | 41.08 | 41 | 14.06 | 370 | 6 | 8 |
7 | 0.16 | 181 | 14.15 | 323 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.84 | 27 | 14.06 | 464 | 6 | 6 |
2 | 1012.24 | 50 | 7.20 | 1764 | 6 | 6 |
3 | 865.52 | 40 | 12.17 | 1643 | 6 | 6 |
4 | 174.12 | 40 | 13.74 | 600 | 6 | 7 |
5 | 16.40 | 41 | 14.13 | 323 | 6 | 8 |
6 | 0.04 | 181 | 14.14 | 331 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.24 | 27 | 14.06 | 482 | 6 | 6 |
2 | 1042.52 | 1 | 11.38 | 1857 | 6 | 6 |
3 | 1019.92 | 1 | 10.07 | 1821 | 6 | 6 |
4 | 1127.56 | 10 | 11.25 | 2013 | 6 | 6 |
5 | 1767.56 | 96 | 8.96 | 2902 | 6 | 6 |
6 | 1758.76 | 50 | 9.70 | 2887 | 6 | 6 |
7 | 253.76 | 40 | 13.60 | 763 | 6 | 8 |
8 | 21.48 | 40 | 14.10 | 367 | 6 | 8 |
9 | 0.04 | 181 | 14.16 | 339 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.32 | 31 | 14.00 | 482 | 6 | 6 |
2 | 946.28 | -1 | 14.00 | 482 | 6 | 6 |
3 | 1005.20 | 50 | 6.75 | 1740 | 6 | 6 |
4 | 860.60 | 40 | 12.01 | 1640 | 6 | 6 |
5 | 183.84 | 40 | 13.68 | 620 | 6 | 7 |
6 | 0.08 | 181 | 14.12 | 322 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.32 | 28 | 14.06 | 464 | 7 | 7 |
2 | 976.36 | -1 | 14.06 | 464 | 7 | 7 |
3 | 1021.52 | 1 | 10.69 | 1857 | 6 | 6 |
4 | 1022.28 | 50 | 7.28 | 1776 | 6 | 6 |
5 | 857.20 | 40 | 12.21 | 1635 | 6 | 6 |
6 | 180.64 | 40 | 13.75 | 607 | 6 | 7 |
7 | 0.84 | 180 | 14.16 | 318 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 27 | 14.06 | 482 | 6 | 6 |
2 | 1110.60 | 10 | 11.08 | 2013 | 6 | 6 |
3 | 1842.48 | 96 | 8.84 | 3023 | 6 | 6 |
4 | 1833.84 | 50 | 9.68 | 3006 | 6 | 6 |
5 | 345.24 | 40 | 13.45 | 890 | 6 | 7 |
6 | 66.88 | 40 | 14.05 | 422 | 6 | 8 |
7 | 0.04 | 181 | 14.22 | 330 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 28 | 13.93 | 482 | 7 | 7 |
2 | 1078.32 | 2 | 11.38 | 1910 | 6 | 6 |
3 | 1030.48 | 1 | 11.00 | 1857 | 6 | 6 |
4 | 1020.88 | 50 | 6.59 | 1748 | 6 | 6 |
5 | 871.92 | 40 | 12.03 | 1640 | 6 | 6 |
6 | 202.08 | 40 | 13.66 | 637 | 6 | 7 |
7 | 45.08 | 41 | 14.08 | 361 | 6 | 8 |
8 | 0.12 | 181 | 14.18 | 306 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.04 | 28 | 14.18 | 464 | 7 | 7 |
2 | 995.56 | 50 | 7.45 | 1746 | 7 | 6 |
3 | 815.64 | 40 | 12.26 | 1574 | 6 | 6 |
4 | 159.12 | 40 | 13.77 | 567 | 6 | 7 |
5 | 0.88 | 180 | 14.18 | 324 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 27 | 14.00 | 464 | 7 | 7 |
2 | 1101.24 | 10 | 11.14 | 1968 | 6 | 6 |
3 | 1829.16 | 96 | 8.93 | 2967 | 6 | 6 |
4 | 1821.08 | 50 | 9.65 | 2999 | 6 | 6 |
5 | 307.40 | 40 | 13.52 | 841 | 6 | 8 |
6 | 61.60 | 40 | 14.09 | 406 | 6 | 8 |
7 | 0.16 | 181 | 14.24 | 331 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.00 | 28 | 14.06 | 482 | 7 | 7 |
2 | 1000.36 | 50 | 7.01 | 1782 | 7 | 6 |
3 | 841.56 | 40 | 12.02 | 1615 | 6 | 6 |
4 | 190.56 | 40 | 13.69 | 628 | 6 | 7 |
5 | 8.64 | 41 | 14.19 | 306 | 6 | 8 |
6 | 0.12 | 181 | 14.23 | 309 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 29 | 14.18 | 464 | 7 | 7 |
2 | 962.20 | -1 | 14.18 | 464 | 7 | 7 |
3 | 1011.28 | 50 | 7.58 | 1811 | 6 | 6 |
4 | 842.40 | 40 | 12.23 | 1625 | 6 | 6 |
5 | 176.20 | 41 | 13.74 | 605 | 6 | 7 |
6 | 14.80 | 41 | 14.17 | 333 | 6 | 8 |
7 | 0.04 | 181 | 14.23 | 321 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.76 | 29 | 14.12 | 482 | 7 | 7 |
2 | 960.64 | -1 | 14.12 | 482 | 7 | 7 |
3 | 1115.52 | 10 | 11.40 | 1999 | 6 | 6 |
4 | 1807.00 | 96 | 9.27 | 2950 | 6 | 6 |
5 | 1800.08 | 50 | 9.87 | 2940 | 6 | 6 |
6 | 272.24 | 40 | 13.60 | 788 | 6 | 8 |
7 | 58.16 | 40 | 14.10 | 424 | 6 | 8 |
8 | 0.16 | 180 | 14.26 | 332 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.40 | 28 | 14.18 | 464 | 7 | 7 |
2 | 1003.40 | 50 | 7.22 | 1782 | 7 | 6 |
3 | 832.20 | 40 | 12.21 | 1594 | 6 | 6 |
4 | 174.24 | 40 | 13.79 | 594 | 6 | 7 |
5 | 38.12 | 41 | 14.14 | 359 | 6 | 8 |
6 | 0.16 | 181 | 14.24 | 323 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.20 | 27 | 14.25 | 482 | 7 | 7 |
2 | 1005.52 | 3 | 12.06 | 1875 | 6 | 6 |
3 | 955.88 | -1 | 12.06 | 1875 | 6 | 6 |
4 | 1116.88 | 96 | 8.32 | 1933 | 6 | 6 |
5 | 1121.28 | 50 | 9.87 | 1944 | 6 | 6 |
6 | 227.48 | 41 | 13.66 | 694 | 6 | 7 |
7 | 56.68 | 41 | 14.10 | 388 | 6 | 7 |
8 | 0.08 | 181 | 14.27 | 317 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.80 | 22 | 14.12 | 500 | 7 | 7 |
2 | 1030.96 | 3 | 12.25 | 1857 | 6 | 6 |
3 | 1083.04 | 2 | 11.38 | 1982 | 6 | 6 |
4 | 1028.12 | 1 | 10.69 | 1839 | 6 | 6 |
5 | 1127.88 | 10 | 11.64 | 2026 | 6 | 6 |
6 | 1829.88 | 96 | 9.98 | 2986 | 6 | 6 |
7 | 1820.32 | 50 | 10.14 | 2983 | 6 | 6 |
8 | 196.72 | 40 | 13.77 | 658 | 6 | 7 |
9 | 47.80 | 40 | 14.15 | 404 | 6 | 8 |
10 | 0.08 | 181 | 14.31 | 336 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 115.52 | 27 | 14.25 | 482 | 7 | 7 |
2 | 1025.52 | 1 | 10.88 | 1910 | 6 | 6 |
3 | 1019.12 | 1 | 10.38 | 1839 | 6 | 6 |
4 | 1122.72 | 10 | 5.62 | 1931 | 6 | 6 |
5 | 2001.64 | 96 | 5.13 | 3021 | 6 | 6 |
6 | 2004.00 | 50 | 8.79 | 3196 | 6 | 6 |
7 | 1850.24 | 40 | 11.14 | 3011 | 6 | 6 |
8 | 1243.08 | 40 | 12.16 | 2168 | 6 | 6 |
9 | 283.76 | 40 | 13.61 | 786 | 6 | 8 |
10 | 59.60 | 40 | 14.18 | 383 | 6 | 7 |
11 | 0.16 | 181 | 14.34 | 311 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.04 | 26 | 14.31 | 464 | 7 | 7 |
2 | 1029.88 | 1 | 11.57 | 1839 | 6 | 6 |
3 | 1136.44 | 10 | 5.82 | 2024 | 6 | 6 |
4 | 2001.28 | 96 | 5.19 | 3264 | 6 | 6 |
5 | 2003.00 | 50 | 9.18 | 3237 | 6 | 6 |
6 | 1834.40 | 40 | 11.04 | 3024 | 6 | 6 |
7 | 1180.28 | 40 | 12.22 | 2086 | 6 | 6 |
8 | 231.44 | 40 | 13.70 | 700 | 6 | 7 |
9 | 52.44 | 40 | 14.18 | 374 | 6 | 8 |
10 | 0.04 | 181 | 14.34 | 310 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.84 | 29 | 14.25 | 482 | 7 | 7 |
2 | 882.92 | -3 | 14.25 | 482 | 7 | 7 |
3 | 1128.44 | 3 | 4.97 | 1946 | 6 | 6 |
4 | 1794.20 | 20 | 5.09 | 2658 | 6 | 6 |
5 | 1794.16 | 75 | 7.36 | 2921 | 6 | 6 |
6 | 1654.00 | 40 | 11.16 | 2744 | 6 | 6 |
7 | 1032.76 | 40 | 12.36 | 1890 | 6 | 6 |
8 | 184.04 | 41 | 13.82 | 607 | 6 | 7 |
9 | 45.24 | 41 | 14.19 | 376 | 6 | 8 |
10 | 0.16 | 181 | 14.31 | 336 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.44 | 27 | 14.12 | 500 | 7 | 7 |
2 | 1056.28 | 1 | 11.38 | 1964 | 6 | 6 |
3 | 1029.04 | 1 | 11.07 | 1892 | 6 | 6 |
4 | 1143.64 | 3 | 4.94 | 1687 | 6 | 6 |
5 | 2001.52 | 20 | 5.00 | 2224 | 6 | 6 |
6 | 2002.80 | 76 | 5.68 | 3167 | 6 | 6 |
7 | 1946.08 | 40 | 10.86 | 3128 | 6 | 6 |
8 | 1763.00 | 40 | 11.41 | 2904 | 6 | 6 |
9 | 869.24 | 40 | 12.71 | 1654 | 6 | 7 |
10 | 166.84 | 41 | 13.86 | 585 | 6 | 8 |
11 | 17.48 | 41 | 14.27 | 325 | 6 | 8 |
12 | 0.12 | 181 | 14.32 | 338 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.44 | 27 | 14.18 | 482 | 7 | 7 |
2 | 1118.92 | 3 | 4.97 | 1937 | 6 | 6 |
3 | 1372.24 | 20 | 6.17 | 2314 | 6 | 6 |
4 | 1372.32 | 75 | 8.43 | 2312 | 6 | 6 |
5 | 1231.76 | 40 | 11.67 | 2150 | 6 | 6 |
6 | 349.48 | 40 | 13.42 | 899 | 6 | 7 |
7 | 73.76 | 40 | 14.06 | 419 | 6 | 8 |
8 | 0.12 | 181 | 14.23 | 334 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.56 | 28 | 14.18 | 482 | 6 | 7 |
2 | 959.56 | -1 | 14.18 | 482 | 6 | 7 |
3 | 1139.48 | 3 | 4.94 | 1839 | 6 | 6 |
4 | 1766.16 | 20 | 5.05 | 2432 | 6 | 6 |
5 | 1766.12 | 75 | 6.86 | 2923 | 6 | 6 |
6 | 1620.32 | 41 | 11.20 | 2706 | 6 | 6 |
7 | 1225.04 | 41 | 12.11 | 2143 | 6 | 6 |
8 | 283.80 | 41 | 13.58 | 795 | 6 | 8 |
9 | 53.60 | 41 | 14.15 | 391 | 6 | 8 |
10 | 0.12 | 181 | 14.27 | 338 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.76 | 27 | 14.18 | 482 | 7 | 7 |
2 | 1118.20 | 3 | 5.00 | 2000 | 6 | 6 |
3 | 1420.80 | 20 | 6.38 | 2379 | 6 | 6 |
4 | 1420.76 | 75 | 8.78 | 2392 | 6 | 6 |
5 | 1219.40 | 40 | 11.80 | 2141 | 6 | 6 |
6 | 328.12 | 40 | 13.45 | 867 | 6 | 8 |
7 | 64.80 | 40 | 14.08 | 410 | 6 | 8 |
8 | 0.20 | 180 | 14.23 | 327 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.52 | 26 | 14.18 | 500 | 7 | 7 |
2 | 1038.80 | 1 | 11.44 | 1875 | 6 | 6 |
3 | 1019.56 | 1 | 10.13 | 1857 | 6 | 6 |
4 | 1126.16 | 3 | 4.97 | 1937 | 6 | 6 |
5 | 1966.56 | 20 | 5.08 | 2620 | 6 | 6 |
6 | 1968.08 | 75 | 6.43 | 3359 | 6 | 6 |
7 | 1869.20 | 40 | 11.19 | 3006 | 6 | 6 |
8 | 1462.84 | 40 | 11.87 | 2498 | 6 | 6 |
9 | 575.20 | 40 | 13.16 | 1229 | 6 | 7 |
10 | 79.04 | 41 | 14.12 | 424 | 6 | 8 |
11 | 0.12 | 181 | 14.32 | 326 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.00 | 27 | 14.12 | 500 | 7 | 7 |
2 | 974.56 | -1 | 14.12 | 500 | 7 | 7 |
3 | 1144.52 | 3 | 4.97 | 1901 | 6 | 6 |
4 | 2000.36 | 20 | 5.08 | 2546 | 6 | 6 |
5 | 2000.72 | 75 | 5.99 | 3335 | 6 | 6 |
6 | 1902.00 | 41 | 11.05 | 3110 | 6 | 6 |
7 | 1719.08 | 41 | 11.53 | 2836 | 6 | 6 |
8 | 795.20 | 40 | 12.80 | 1566 | 6 | 7 |
9 | 133.72 | 40 | 13.94 | 537 | 6 | 8 |
10 | 0.08 | 181 | 14.30 | 339 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.72 | 27 | 14.25 | 482 | 7 | 7 |
2 | 1113.88 | 3 | 4.97 | 1946 | 6 | 6 |
3 | 1803.44 | 20 | 5.09 | 2597 | 6 | 6 |
4 | 1805.04 | 75 | 7.66 | 2927 | 6 | 6 |
5 | 1672.48 | 40 | 11.26 | 2768 | 6 | 6 |
6 | 1006.32 | 40 | 12.45 | 1850 | 6 | 6 |
7 | 148.72 | 41 | 13.94 | 539 | 6 | 7 |
8 | 16.36 | 41 | 14.27 | 340 | 6 | 8 |
9 | 0.12 | 181 | 14.32 | 337 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.96 | 26 | 14.25 | 482 | 7 | 7 |
2 | 1026.44 | 1 | 10.82 | 1892 | 6 | 6 |
3 | 1144.16 | 3 | 4.97 | 1874 | 6 | 6 |
4 | 1995.96 | 20 | 5.07 | 2508 | 6 | 6 |
5 | 1996.16 | 75 | 6.51 | 3411 | 6 | 6 |
6 | 1887.48 | 40 | 11.17 | 3078 | 6 | 6 |
7 | 1484.04 | 40 | 11.92 | 2521 | 6 | 6 |
8 | 561.88 | 40 | 13.17 | 1225 | 6 | 7 |
9 | 79.56 | 40 | 14.12 | 428 | 6 | 8 |
10 | 0.20 | 181 | 14.38 | 302 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.24 | 28 | 14.31 | 464 | 7 | 7 |
2 | 918.92 | -2 | 14.31 | 464 | 7 | 7 |
3 | 1124.80 | 3 | 4.94 | 1839 | 6 | 6 |
4 | 2003.20 | 20 | 5.05 | 2472 | 6 | 6 |
5 | 2003.72 | 75 | 6.26 | 3431 | 6 | 6 |
6 | 1907.80 | 41 | 11.23 | 3097 | 6 | 6 |
7 | 1515.00 | 41 | 11.89 | 2557 | 6 | 6 |
8 | 614.16 | 41 | 13.11 | 1291 | 6 | 7 |
9 | 89.48 | 41 | 14.11 | 446 | 6 | 8 |
10 | 0.12 | 181 | 14.33 | 326 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.36 | 27 | 14.25 | 482 | 7 | 7 |
2 | 1119.08 | 3 | 4.94 | 1848 | 6 | 6 |
3 | 1985.36 | 20 | 5.06 | 2495 | 6 | 6 |
4 | 1984.68 | 76 | 6.44 | 3376 | 6 | 6 |
5 | 1842.32 | 40 | 11.31 | 3028 | 6 | 6 |
6 | 1443.28 | 40 | 11.99 | 2480 | 6 | 6 |
7 | 526.56 | 40 | 13.26 | 1169 | 6 | 7 |
8 | 71.84 | 41 | 14.16 | 415 | 6 | 7 |
9 | 0.12 | 181 | 14.34 | 323 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.36 | 27 | 14.25 | 482 | 7 | 7 |
2 | 1104.52 | 3 | 4.94 | 1758 | 6 | 6 |
3 | 1996.96 | 20 | 4.98 | 2204 | 6 | 6 |
4 | 1997.40 | 75 | 5.52 | 3241 | 6 | 6 |
5 | 1941.24 | 40 | 11.16 | 3155 | 6 | 6 |
6 | 1753.88 | 40 | 11.64 | 2918 | 6 | 6 |
7 | 853.28 | 40 | 12.82 | 1641 | 6 | 7 |
8 | 109.68 | 41 | 14.10 | 476 | 6 | 7 |
9 | 0.20 | 181 | 14.36 | 328 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.08 | 29 | 14.31 | 464 | 7 | 7 |
2 | 934.40 | -1 | 14.31 | 464 | 7 | 7 |
3 | 1204.80 | 3 | 4.91 | 1678 | 6 | 7 |
4 | 1540.72 | 20 | 4.94 | 2030 | 6 | 6 |
5 | 1540.72 | 76 | 7.15 | 2540 | 6 | 6 |
6 | 1456.40 | 40 | 11.73 | 2491 | 6 | 6 |
7 | 1260.20 | 40 | 12.18 | 2199 | 6 | 6 |
8 | 160.28 | 40 | 13.94 | 572 | 6 | 7 |
9 | 39.44 | 41 | 14.25 | 368 | 6 | 8 |
10 | 0.16 | 180 | 14.32 | 341 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.24 | 26 | 14.25 | 482 | 7 | 7 |
2 | 1058.16 | 2 | 11.63 | 1946 | 6 | 6 |
3 | 1028.64 | 1 | 10.69 | 1875 | 6 | 6 |
4 | 1115.96 | 3 | 4.94 | 1758 | 6 | 6 |
5 | 1499.08 | 20 | 5.02 | 2350 | 6 | 6 |
6 | 1499.00 | 76 | 8.88 | 2517 | 6 | 6 |
7 | 1322.84 | 40 | 12.00 | 2285 | 6 | 6 |
8 | 453.88 | 40 | 13.34 | 1055 | 6 | 7 |
9 | 87.32 | 40 | 14.09 | 449 | 6 | 8 |
10 | 0.08 | 181 | 14.31 | 310 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.36 | 28 | 14.31 | 446 | 7 | 7 |
2 | 956.12 | -1 | 14.31 | 446 | 7 | 7 |
3 | 1108.76 | 3 | 4.94 | 1722 | 6 | 6 |
4 | 1869.12 | 20 | 4.97 | 2149 | 6 | 6 |
5 | 1869.04 | 76 | 6.16 | 3205 | 6 | 6 |
6 | 1810.24 | 40 | 11.42 | 2985 | 6 | 6 |
7 | 1616.44 | 40 | 11.83 | 2711 | 6 | 6 |
8 | 504.24 | 40 | 13.36 | 1120 | 6 | 7 |
9 | 122.68 | 41 | 14.05 | 504 | 6 | 8 |
10 | 0.08 | 180 | 14.34 | 329 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.32 | 27 | 14.31 | 446 | 6 | 6 |
2 | 1127.84 | 3 | 4.91 | 1669 | 6 | 6 |
3 | 1691.56 | 20 | 4.97 | 2091 | 6 | 6 |
4 | 1691.88 | 76 | 7.36 | 2743 | 6 | 6 |
5 | 1561.60 | 40 | 11.68 | 2642 | 6 | 6 |
6 | 902.80 | 40 | 12.71 | 1709 | 6 | 7 |
7 | 115.68 | 41 | 14.07 | 493 | 6 | 8 |
8 | 26.04 | 41 | 14.30 | 340 | 6 | 8 |
9 | 0.08 | 180 | 14.38 | 307 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.52 | 27 | 14.31 | 464 | 7 | 7 |
2 | 1121.56 | 3 | 4.94 | 1722 | 6 | 6 |
3 | 1540.52 | 20 | 4.98 | 2184 | 6 | 6 |
4 | 1540.52 | 75 | 8.01 | 2548 | 6 | 6 |
5 | 1366.64 | 40 | 11.91 | 2344 | 6 | 6 |
6 | 716.96 | 40 | 12.96 | 1452 | 6 | 7 |
7 | 109.36 | 40 | 14.06 | 486 | 6 | 8 |
8 | 0.60 | 180 | 14.33 | 312 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 27 | 14.25 | 482 | 6 | 7 |
2 | 1109.92 | 3 | 4.94 | 1705 | 6 | 7 |
3 | 1635.80 | 20 | 4.97 | 2124 | 6 | 6 |
4 | 1635.76 | 76 | 7.38 | 2667 | 6 | 6 |
5 | 1513.84 | 40 | 11.89 | 2559 | 6 | 6 |
6 | 707.52 | 40 | 13.01 | 1434 | 6 | 7 |
7 | 113.68 | 41 | 14.06 | 497 | 6 | 8 |
8 | 0.12 | 181 | 14.34 | 312 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.80 | 27 | 14.18 | 500 | 7 | 7 |
2 | 1128.80 | 3 | 4.94 | 1740 | 6 | 6 |
3 | 1405.80 | 20 | 5.57 | 2258 | 6 | 6 |
4 | 1405.80 | 75 | 9.00 | 2376 | 6 | 6 |
5 | 1405.80 | 40 | 11.89 | 2422 | 6 | 6 |
6 | 1405.80 | 40 | 12.07 | 2405 | 6 | 6 |
7 | 1405.84 | 40 | 12.10 | 2428 | 6 | 6 |
8 | 1289.64 | 40 | 12.31 | 2227 | 6 | 7 |
9 | 0.04 | 181 | 14.26 | 344 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.84 | 27 | 14.31 | 464 | 7 | 7 |
2 | 1207.88 | 3 | 4.94 | 1758 | 6 | 6 |
3 | 1964.52 | 20 | 5.04 | 2405 | 6 | 6 |
4 | 1964.36 | 75 | 7.71 | 3152 | 6 | 6 |
5 | 1787.16 | 40 | 11.57 | 2961 | 6 | 6 |
6 | 1134.04 | 40 | 12.47 | 2026 | 6 | 6 |
7 | 189.56 | 41 | 13.89 | 634 | 6 | 7 |
8 | 46.48 | 41 | 14.28 | 377 | 6 | 8 |
9 | 0.16 | 181 | 14.33 | 335 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.28 | 28 | 14.31 | 482 | 7 | 7 |
2 | 949.48 | -1 | 14.31 | 482 | 7 | 7 |
3 | 2002.20 | 6 | 4.90 | 1654 | 6 | 6 |
4 | 2002.76 | 75 | 6.47 | 3178 | 6 | 6 |
5 | 1923.32 | 40 | 11.47 | 3169 | 6 | 6 |
6 | 1549.48 | 40 | 12.01 | 2615 | 6 | 6 |
7 | 650.56 | 40 | 13.16 | 1342 | 6 | 7 |
8 | 95.28 | 41 | 14.15 | 456 | 6 | 8 |
9 | 0.24 | 181 | 14.34 | 332 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.76 | 27 | 14.31 | 482 | 7 | 7 |
2 | 1034.24 | 1 | 11.19 | 1875 | 6 | 6 |
3 | 2003.88 | 6 | 4.90 | 1636 | 6 | 6 |
4 | 2005.52 | 76 | 6.77 | 3290 | 6 | 6 |
5 | 1926.96 | 40 | 11.52 | 3124 | 6 | 6 |
6 | 1523.36 | 40 | 12.02 | 2572 | 6 | 6 |
7 | 816.56 | 40 | 12.93 | 1586 | 6 | 7 |
8 | 85.56 | 41 | 14.18 | 443 | 6 | 8 |
9 | 0.12 | 181 | 14.37 | 324 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.12 | 29 | 14.31 | 446 | 6 | 7 |
2 | 898.32 | -2 | 14.31 | 446 | 6 | 7 |
3 | 2007.32 | 6 | 4.90 | 1666 | 6 | 6 |
4 | 2009.04 | 75 | 6.61 | 3298 | 6 | 6 |
5 | 1931.28 | 40 | 11.48 | 3120 | 6 | 6 |
6 | 1533.08 | 40 | 12.01 | 2586 | 6 | 6 |
7 | 624.00 | 40 | 13.19 | 1310 | 6 | 7 |
8 | 84.32 | 41 | 14.14 | 449 | 6 | 8 |
9 | 0.16 | 181 | 14.31 | 336 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.80 | 27 | 14.31 | 482 | 7 | 7 |
2 | 1000.36 | 3 | 12.62 | 1839 | 6 | 6 |
3 | 939.48 | -1 | 12.62 | 1839 | 6 | 6 |
4 | 2005.96 | 6 | 4.92 | 1708 | 6 | 6 |
5 | 2008.04 | 75 | 7.42 | 3171 | 6 | 6 |
6 | 1872.48 | 40 | 11.54 | 3068 | 6 | 6 |
7 | 1462.32 | 40 | 12.09 | 2483 | 6 | 6 |
8 | 306.16 | 41 | 13.67 | 835 | 6 | 8 |
9 | 65.76 | 41 | 14.19 | 415 | 6 | 8 |
10 | -0.08 | 180 | 14.34 | 306 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.84 | 28 | 14.31 | 482 | 7 | 7 |
2 | 954.72 | -1 | 14.31 | 482 | 7 | 7 |
3 | 2012.80 | 6 | 4.92 | 1779 | 6 | 6 |
4 | 2015.24 | 75 | 7.33 | 3260 | 6 | 6 |
5 | 1922.88 | 40 | 11.47 | 3119 | 6 | 6 |
6 | 1314.40 | 40 | 12.24 | 2302 | 6 | 6 |
7 | 404.08 | 41 | 13.52 | 983 | 6 | 8 |
8 | 70.64 | 41 | 14.18 | 422 | 6 | 8 |
9 | 0.08 | 181 | 14.32 | 335 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.96 | 27 | 14.25 | 482 | 7 | 7 |
2 | 1034.24 | 1 | 10.57 | 1892 | 6 | 6 |
3 | 2002.64 | 6 | 4.94 | 1833 | 6 | 6 |
4 | 2003.92 | 75 | 7.86 | 3294 | 6 | 6 |
5 | 1848.00 | 40 | 11.60 | 3027 | 6 | 6 |
6 | 1216.56 | 40 | 12.38 | 2145 | 6 | 6 |
7 | 279.12 | 41 | 13.73 | 791 | 6 | 8 |
8 | 55.80 | 41 | 14.23 | 397 | 6 | 8 |
9 | 0.00 | 181 | 14.31 | 324 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.64 | 28 | 14.31 | 482 | 7 | 7 |
2 | 976.48 | -1 | 14.31 | 482 | 7 | 7 |
3 | 2001.24 | 6 | 4.96 | 1934 | 6 | 6 |
4 | 2002.24 | 75 | 7.94 | 3233 | 6 | 6 |
5 | 1813.24 | 40 | 11.57 | 3001 | 6 | 6 |
6 | 1151.52 | 40 | 12.45 | 2064 | 6 | 6 |
7 | 223.44 | 41 | 13.81 | 697 | 6 | 7 |
8 | 49.52 | 41 | 14.27 | 386 | 6 | 8 |
9 | 0.08 | 181 | 14.31 | 334 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.12 | 28 | 14.31 | 482 | 7 | 7 |
2 | 1117.76 | 2 | 4.97 | 2035 | 6 | 6 |
3 | 1993.64 | 75 | 7.75 | 3233 | 6 | 6 |
4 | 1825.76 | 41 | 11.56 | 2990 | 6 | 6 |
5 | 1203.12 | 41 | 12.41 | 2119 | 6 | 6 |
6 | 149.48 | 41 | 14.03 | 562 | 6 | 8 |
7 | 33.92 | 41 | 14.27 | 383 | 6 | 8 |
8 | 0.08 | 181 | 14.31 | 340 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.56 | 27 | 14.25 | 500 | 7 | 7 |
2 | 1130.68 | 2 | 5.87 | 1946 | 6 | 6 |
3 | 1982.52 | 75 | 8.30 | 3185 | 6 | 6 |
4 | 1793.88 | 41 | 11.59 | 2983 | 6 | 6 |
5 | 887.00 | 41 | 12.80 | 1694 | 6 | 7 |
6 | 110.32 | 41 | 14.12 | 492 | 6 | 7 |
7 | 0.12 | 181 | 14.35 | 323 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.96 | 27 | 14.31 | 464 | 7 | 7 |
2 | 1210.68 | 2 | 5.03 | 2160 | 6 | 6 |
3 | 2006.28 | 75 | 8.31 | 3210 | 6 | 6 |
4 | 1858.04 | 38 | 11.60 | 3036 | 6 | 6 |
5 | 1034.52 | 38 | 12.68 | 1903 | 6 | 6 |
6 | 189.68 | 38 | 13.93 | 643 | 6 | 7 |
7 | 44.76 | 38 | 14.26 | 386 | 6 | 8 |
8 | -0.04 | 181 | 14.28 | 337 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 27 | 14.25 | 482 | 6 | 7 |
2 | 1115.12 | 2 | 6.25 | 1981 | 6 | 6 |
3 | 1976.84 | 75 | 8.53 | 3160 | 6 | 6 |
4 | 1779.36 | 38 | 11.65 | 2954 | 6 | 6 |
5 | 882.40 | 38 | 12.87 | 1682 | 6 | 6 |
6 | 109.64 | 38 | 14.10 | 498 | 6 | 7 |
7 | 27.60 | 38 | 14.31 | 351 | 6 | 8 |
8 | 0.16 | 180 | 14.31 | 334 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.08 | 28 | 14.31 | 464 | 7 | 7 |
2 | 955.00 | -1 | 14.31 | 464 | 7 | 7 |
3 | 1116.00 | 2 | 6.32 | 2017 | 6 | 6 |
4 | 1966.24 | 75 | 8.46 | 3148 | 6 | 6 |
5 | 1762.64 | 38 | 11.64 | 2942 | 6 | 6 |
6 | 897.20 | 38 | 12.81 | 1722 | 6 | 7 |
7 | 101.00 | 38 | 14.09 | 487 | 6 | 8 |
8 | 11.64 | 38 | 14.34 | 334 | 6 | 8 |
9 | 0.04 | 181 | 14.26 | 343 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.40 | 27 | 14.18 | 500 | 6 | 7 |
2 | 1026.68 | 1 | 10.00 | 1892 | 6 | 6 |
3 | 1128.52 | 2 | 6.41 | 2062 | 6 | 6 |
4 | 1959.80 | 75 | 8.97 | 3159 | 6 | 6 |
5 | 1567.00 | 38 | 11.91 | 2660 | 6 | 6 |
6 | 672.48 | 38 | 13.15 | 1380 | 6 | 7 |
7 | 85.12 | 38 | 14.13 | 453 | 6 | 8 |
8 | 0.12 | 181 | 14.26 | 337 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.76 | 29 | 14.25 | 482 | 6 | 6 |
2 | 952.32 | -1 | 14.25 | 482 | 6 | 6 |
3 | 1107.80 | 2 | 7.09 | 1946 | 6 | 6 |
4 | 1972.04 | 75 | 8.98 | 3207 | 6 | 6 |
5 | 1578.00 | 38 | 11.90 | 2665 | 6 | 6 |
6 | 675.24 | 38 | 13.14 | 1377 | 6 | 7 |
7 | 83.84 | 38 | 14.10 | 460 | 6 | 8 |
8 | 0.96 | 180 | 14.23 | 341 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.80 | 26 | 14.25 | 482 | 6 | 7 |
2 | 1052.24 | 1 | 11.44 | 1946 | 6 | 6 |
3 | 1031.64 | 1 | 10.82 | 1839 | 6 | 6 |
4 | 1117.16 | 2 | 7.10 | 1928 | 6 | 6 |
5 | 1952.72 | 75 | 9.30 | 3179 | 6 | 6 |
6 | 1764.48 | 38 | 11.69 | 2911 | 6 | 6 |
7 | 805.24 | 38 | 12.93 | 1582 | 6 | 7 |
8 | 73.84 | 38 | 14.13 | 448 | 6 | 8 |
9 | 0.08 | 181 | 14.24 | 337 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.24 | 28 | 14.31 | 482 | 7 | 7 |
2 | 928.32 | -2 | 14.31 | 482 | 7 | 7 |
3 | 1135.56 | 2 | 7.56 | 1955 | 6 | 6 |
4 | 1956.56 | 75 | 9.41 | 3153 | 6 | 6 |
5 | 1527.36 | 38 | 11.92 | 2606 | 6 | 6 |
6 | 600.48 | 38 | 13.22 | 1276 | 6 | 7 |
7 | 69.20 | 38 | 14.11 | 435 | 6 | 8 |
8 | 0.08 | 181 | 14.21 | 343 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 28 | 14.31 | 482 | 6 | 7 |
2 | 1116.28 | 2 | 7.41 | 1955 | 6 | 6 |
3 | 1964.00 | 75 | 9.51 | 3188 | 6 | 6 |
4 | 1343.00 | 38 | 12.18 | 2321 | 6 | 6 |
5 | 473.64 | 38 | 13.40 | 1092 | 6 | 7 |
6 | 55.00 | 38 | 14.20 | 408 | 6 | 8 |
7 | 0.12 | 181 | 14.23 | 336 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 28 | 14.25 | 482 | 7 | 7 |
2 | 1101.36 | 2 | 7.09 | 1955 | 6 | 6 |
3 | 1972.48 | 75 | 9.61 | 3187 | 6 | 6 |
4 | 1350.04 | 38 | 12.19 | 2343 | 6 | 6 |
5 | 647.00 | 38 | 13.18 | 1352 | 6 | 7 |
6 | 69.64 | 38 | 14.16 | 431 | 6 | 8 |
7 | 0.08 | 181 | 14.22 | 340 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.92 | 28 | 14.31 | 482 | 7 | 7 |
2 | 1204.12 | 2 | 6.81 | 2089 | 6 | 6 |
3 | 2002.40 | 75 | 9.88 | 3225 | 6 | 6 |
4 | 1610.20 | 38 | 11.92 | 2731 | 6 | 6 |
5 | 670.32 | 38 | 13.14 | 1385 | 6 | 7 |
6 | 86.68 | 38 | 14.13 | 458 | 6 | 8 |
7 | 0.20 | 181 | 14.22 | 338 | 6 | 18 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.16 | 27 | 14.25 | 482 | 7 | 6 |
2 | 1029.00 | 3 | 12.56 | 1928 | 6 | 6 |
3 | 976.04 | -1 | 12.56 | 1928 | 6 | 6 |
4 | 2004.16 | 61 | 12.50 | 398 | 6 | 6 |
5 | 2006.12 | 66 | 9.63 | 3655 | 6 | 6 |
6 | 1815.00 | 30 | 12.03 | 2987 | 6 | 6 |
7 | 1218.44 | 30 | 12.67 | 2142 | 6 | 6 |
8 | 553.88 | 30 | 13.40 | 1188 | 6 | 7 |
9 | 83.12 | 30 | 14.17 | 447 | 6 | 8 |
10 | 20.84 | 30 | 14.35 | 343 | 6 | 8 |
11 | 0.04 | 181 | 14.26 | 346 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.32 | 28 | 14.25 | 482 | 7 | 7 |
2 | 922.68 | -2 | 14.25 | 482 | 7 | 7 |
3 | 2002.08 | 61 | 12.48 | 404 | 6 | 6 |
4 | 2004.32 | 66 | 9.59 | 3676 | 6 | 6 |
5 | 1832.24 | 30 | 12.03 | 3039 | 6 | 6 |
6 | 1410.04 | 30 | 12.45 | 2432 | 6 | 6 |
7 | 537.36 | 30 | 13.39 | 1202 | 6 | 7 |
8 | 87.28 | 30 | 14.13 | 462 | 6 | 7 |
9 | 19.88 | 30 | 14.35 | 339 | 6 | 8 |
10 | 0.08 | 180 | 14.28 | 334 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.08 | 28 | 14.25 | 464 | 7 | 7 |
2 | 2002.20 | 61 | 12.57 | 407 | 6 | 6 |
3 | 2004.40 | 66 | 9.80 | 3599 | 6 | 6 |
4 | 1824.88 | 30 | 12.02 | 2998 | 6 | 6 |
5 | 1198.20 | 30 | 12.70 | 2120 | 6 | 6 |
6 | 325.84 | 30 | 13.67 | 874 | 6 | 8 |
7 | 74.04 | 30 | 14.16 | 438 | 6 | 8 |
8 | 0.04 | 181 | 14.24 | 339 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.80 | 29 | 14.18 | 482 | 7 | 7 |
2 | 960.40 | -1 | 14.18 | 482 | 7 | 7 |
3 | 2005.52 | 61 | 12.45 | 407 | 6 | 6 |
4 | 2008.32 | 65 | 9.62 | 3704 | 6 | 6 |
5 | 1843.32 | 31 | 12.03 | 2986 | 6 | 6 |
6 | 1441.88 | 30 | 12.42 | 2471 | 6 | 6 |
7 | 562.68 | 30 | 13.38 | 1228 | 6 | 7 |
8 | 82.36 | 30 | 14.14 | 449 | 6 | 7 |
9 | 19.92 | 30 | 14.32 | 342 | 6 | 8 |
10 | 0.12 | 180 | 14.25 | 335 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.64 | 29 | 14.25 | 482 | 6 | 7 |
2 | 2001.12 | 61 | 12.30 | 407 | 6 | 6 |
3 | 2004.64 | 66 | 9.69 | 3629 | 6 | 6 |
4 | 1826.92 | 30 | 11.99 | 3026 | 6 | 6 |
5 | 1195.16 | 30 | 12.66 | 2127 | 6 | 6 |
6 | 529.64 | 30 | 13.39 | 1188 | 6 | 7 |
7 | 73.12 | 30 | 14.18 | 431 | 6 | 8 |
8 | 2.36 | 30 | 14.39 | 318 | 6 | 8 |
9 | 0.04 | 180 | 14.22 | 349 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.92 | 29 | 14.31 | 482 | 7 | 7 |
2 | 2000.16 | 61 | 12.36 | 399 | 6 | 6 |
3 | 2003.36 | 66 | 9.69 | 3618 | 6 | 6 |
4 | 1836.84 | 30 | 12.00 | 3007 | 6 | 6 |
5 | 1207.20 | 30 | 12.65 | 2139 | 6 | 6 |
6 | 526.96 | 30 | 13.43 | 1151 | 6 | 7 |
7 | 77.12 | 30 | 14.16 | 441 | 6 | 8 |
8 | 0.16 | 180 | 14.24 | 343 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.84 | 29 | 14.18 | 482 | 7 | 7 |
2 | 2007.44 | 61 | 12.17 | 392 | 6 | 6 |
3 | 2010.28 | 65 | 9.50 | 3752 | 6 | 6 |
4 | 1856.76 | 31 | 11.97 | 3060 | 6 | 6 |
5 | 1423.56 | 31 | 12.44 | 2429 | 6 | 6 |
6 | 592.28 | 31 | 13.33 | 1268 | 6 | 7 |
7 | 102.64 | 30 | 14.11 | 479 | 6 | 7 |
8 | 25.04 | 30 | 14.31 | 363 | 6 | 8 |
9 | 0.08 | 180 | 14.24 | 342 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.52 | 29 | 14.25 | 482 | 7 | 6 |
2 | 2002.08 | 61 | 12.08 | 404 | 6 | 6 |
3 | 2004.88 | 66 | 9.83 | 3485 | 6 | 6 |
4 | 1806.80 | 30 | 12.01 | 2986 | 6 | 6 |
5 | 1151.00 | 30 | 12.73 | 2063 | 6 | 6 |
6 | 288.52 | 30 | 13.71 | 812 | 6 | 7 |
7 | 72.20 | 30 | 14.18 | 431 | 6 | 8 |
8 | 0.08 | 181 | 14.22 | 339 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.72 | 30 | 14.25 | 482 | 7 | 7 |
2 | 971.12 | -1 | 14.25 | 482 | 7 | 7 |
3 | 1019.48 | 1 | 8.88 | 1839 | 6 | 6 |
4 | 2002.48 | 61 | 12.20 | 400 | 6 | 6 |
5 | 2004.32 | 66 | 10.09 | 3398 | 6 | 6 |
6 | 1809.48 | 30 | 12.00 | 3005 | 6 | 6 |
7 | 1157.96 | 30 | 12.67 | 2079 | 6 | 6 |
8 | 254.84 | 30 | 13.78 | 752 | 6 | 7 |
9 | 62.40 | 30 | 14.22 | 413 | 6 | 8 |
10 | 0.08 | 181 | 14.21 | 340 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.32 | 30 | 14.25 | 482 | 6 | 7 |
2 | 1606.16 | 61 | 12.12 | 399 | 6 | 6 |
3 | 1606.88 | 66 | 10.06 | 3119 | 6 | 6 |
4 | 1423.76 | 30 | 12.41 | 2450 | 6 | 6 |
5 | 1008.56 | 30 | 12.86 | 1871 | 6 | 6 |
6 | 182.28 | 30 | 13.90 | 642 | 6 | 7 |
7 | 51.28 | 30 | 14.18 | 426 | 6 | 7 |
8 | 0.16 | 181 | 14.20 | 346 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.56 | 30 | 14.25 | 482 | 6 | 6 |
2 | 2003.44 | 61 | 12.11 | 404 | 6 | 6 |
3 | 2005.92 | 65 | 9.90 | 3523 | 6 | 6 |
4 | 1826.12 | 31 | 12.02 | 3002 | 6 | 6 |
5 | 1220.44 | 31 | 12.62 | 2158 | 6 | 6 |
6 | 346.76 | 30 | 13.61 | 902 | 6 | 8 |
7 | 79.64 | 30 | 14.13 | 459 | 6 | 8 |
8 | 0.16 | 181 | 14.18 | 350 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.16 | 29 | 14.18 | 500 | 6 | 6 |
2 | 2002.08 | 61 | 12.08 | 396 | 6 | 6 |
3 | 2004.24 | 66 | 9.79 | 3576 | 6 | 6 |
4 | 1821.12 | 30 | 11.99 | 3008 | 6 | 6 |
5 | 1203.88 | 30 | 12.65 | 2134 | 6 | 6 |
6 | 318.92 | 30 | 13.64 | 862 | 6 | 7 |
7 | 82.08 | 30 | 14.15 | 453 | 6 | 7 |
8 | 0.12 | 181 | 14.19 | 345 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.32 | 29 | 14.12 | 500 | 6 | 6 |
2 | 2002.76 | 61 | 11.93 | 394 | 6 | 6 |
3 | 2005.40 | 65 | 9.74 | 3634 | 6 | 6 |
4 | 1841.08 | 31 | 12.01 | 3057 | 6 | 6 |
5 | 1222.52 | 30 | 12.62 | 2176 | 6 | 6 |
6 | 561.28 | 30 | 13.33 | 1233 | 6 | 7 |
7 | 100.48 | 30 | 14.09 | 477 | 6 | 8 |
8 | 10.68 | 30 | 14.38 | 327 | 6 | 8 |
9 | 0.08 | 180 | 14.19 | 345 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.64 | 29 | 14.25 | 500 | 6 | 6 |
2 | 2000.76 | 61 | 11.86 | 395 | 6 | 6 |
3 | 2003.20 | 65 | 9.99 | 3400 | 6 | 6 |
4 | 1822.68 | 30 | 11.97 | 3041 | 6 | 6 |
5 | 978.76 | 31 | 12.84 | 1840 | 6 | 6 |
6 | 188.60 | 31 | 13.86 | 640 | 6 | 7 |
7 | 57.92 | 31 | 14.22 | 401 | 6 | 7 |
8 | 0.08 | 181 | 14.19 | 342 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.08 | 29 | 14.12 | 500 | 6 | 6 |
2 | 2005.40 | 11 | 5.99 | 3356 | 6 | 6 |
3 | 2018.32 | 51 | 11.23 | 3274 | 6 | 6 |
4 | 1820.00 | 35 | 11.88 | 3000 | 6 | 6 |
5 | 954.00 | 35 | 12.78 | 1797 | 6 | 6 |
6 | 139.40 | 35 | 13.95 | 555 | 6 | 8 |
7 | 0.20 | 181 | 14.16 | 341 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 29 | 14.18 | 482 | 6 | 6 |
2 | 2001.88 | 11 | 5.87 | 3231 | 6 | 6 |
3 | 2014.12 | 51 | 11.20 | 3272 | 6 | 6 |
4 | 1649.92 | 35 | 12.03 | 2754 | 6 | 6 |
5 | 831.36 | 35 | 12.93 | 1628 | 6 | 7 |
6 | 108.76 | 35 | 14.01 | 512 | 6 | 8 |
7 | 0.08 | 181 | 14.14 | 351 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.44 | 29 | 14.18 | 500 | 6 | 6 |
2 | 2002.68 | 11 | 6.31 | 3470 | 6 | 6 |
3 | 2011.00 | 51 | 11.31 | 3244 | 6 | 6 |
4 | 1811.00 | 35 | 11.88 | 2989 | 6 | 6 |
5 | 917.04 | 35 | 12.83 | 1739 | 6 | 7 |
6 | 123.84 | 35 | 13.98 | 526 | 6 | 8 |
7 | 0.16 | 181 | 14.18 | 319 | 6 | 14 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.56 | 29 | 14.18 | 500 | 6 | 6 |
2 | 2006.24 | 11 | 5.83 | 3303 | 6 | 6 |
3 | 2021.76 | 51 | 11.18 | 3265 | 6 | 6 |
4 | 1826.88 | 35 | 11.85 | 3028 | 6 | 6 |
5 | 773.92 | 36 | 13.00 | 1533 | 6 | 7 |
6 | 148.56 | 36 | 13.91 | 574 | 6 | 8 |
7 | 0.08 | 180 | 14.16 | 333 | 6 | 12 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 112.80 | 29 | 14.25 | 500 | 6 | 6 |
2 | 2002.32 | 11 | 5.70 | 3295 | 6 | 6 |
3 | 2010.76 | 51 | 11.08 | 3284 | 6 | 6 |
4 | 1814.32 | 35 | 11.90 | 3014 | 6 | 6 |
5 | 964.80 | 35 | 12.78 | 1808 | 6 | 6 |
6 | 131.32 | 35 | 13.95 | 553 | 6 | 8 |
7 | 0.20 | 181 | 14.13 | 340 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.80 | 29 | 14.25 | 482 | 6 | 6 |
2 | 2004.80 | 11 | 5.60 | 3292 | 6 | 6 |
3 | 2015.44 | 51 | 11.00 | 3256 | 6 | 6 |
4 | 1815.84 | 35 | 11.86 | 3007 | 6 | 6 |
5 | 919.56 | 35 | 12.82 | 1750 | 6 | 7 |
6 | 134.88 | 35 | 13.96 | 558 | 6 | 7 |
7 | 2.48 | 35 | 14.36 | 339 | 6 | 8 |
8 | 0.12 | 180 | 14.12 | 343 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.80 | 29 | 14.25 | 500 | 6 | 6 |
2 | 1107.32 | 2 | 5.47 | 1999 | 6 | 6 |
3 | 1990.40 | 11 | 8.79 | 3124 | 6 | 6 |
4 | 1982.96 | 30 | 11.46 | 3214 | 6 | 6 |
5 | 1806.80 | 25 | 12.19 | 2987 | 6 | 6 |
6 | 1183.88 | 25 | 12.79 | 2110 | 6 | 6 |
7 | 545.76 | 25 | 13.42 | 1205 | 6 | 7 |
8 | 148.32 | 25 | 13.96 | 589 | 6 | 7 |
9 | 40.72 | 25 | 14.27 | 408 | 6 | 7 |
10 | 0.08 | 181 | 14.13 | 344 | 6 | 29 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.52 | 28 | 14.31 | 500 | 6 | 6 |
2 | 1044.28 | 1 | 11.38 | 1892 | 6 | 6 |
3 | 1020.88 | 1 | 10.50 | 1857 | 6 | 6 |
4 | 1130.64 | 2 | 5.63 | 2017 | 6 | 6 |
5 | 1978.76 | 11 | 8.75 | 3053 | 6 | 6 |
6 | 1970.76 | 31 | 11.47 | 3192 | 6 | 6 |
7 | 1802.08 | 26 | 12.10 | 2942 | 6 | 6 |
8 | 1179.36 | 25 | 12.81 | 2097 | 6 | 6 |
9 | 545.52 | 25 | 13.41 | 1199 | 6 | 7 |
10 | 92.52 | 25 | 14.12 | 471 | 6 | 7 |
11 | 49.48 | 25 | 14.21 | 411 | 6 | 8 |
12 | 0.20 | 181 | 14.13 | 340 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.80 | 29 | 14.31 | 482 | 6 | 6 |
2 | 951.16 | -1 | 14.31 | 482 | 6 | 6 |
3 | 1133.88 | 5 | 6.46 | 1952 | 6 | 6 |
4 | 1954.36 | 11 | 8.82 | 3260 | 6 | 6 |
5 | 1946.40 | 31 | 11.42 | 3160 | 6 | 6 |
6 | 1775.48 | 25 | 12.24 | 2947 | 6 | 6 |
7 | 1147.64 | 25 | 12.84 | 2078 | 6 | 6 |
8 | 534.76 | 25 | 13.40 | 1217 | 6 | 7 |
9 | 95.08 | 25 | 14.10 | 499 | 6 | 7 |
10 | 51.68 | 25 | 14.24 | 428 | 6 | 7 |
11 | 0.16 | 181 | 14.12 | 349 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.20 | 28 | 14.18 | 500 | 6 | 6 |
2 | 1115.88 | 5 | 6.46 | 1933 | 6 | 6 |
3 | 1936.56 | 11 | 8.61 | 3235 | 6 | 6 |
4 | 1925.80 | 31 | 11.32 | 3141 | 6 | 6 |
5 | 1742.40 | 26 | 12.15 | 2897 | 6 | 6 |
6 | 1138.48 | 25 | 12.86 | 2051 | 6 | 6 |
7 | 505.00 | 25 | 13.47 | 1128 | 6 | 7 |
8 | 138.56 | 25 | 14.00 | 560 | 6 | 7 |
9 | 35.64 | 25 | 14.29 | 373 | 6 | 8 |
10 | 0.00 | 181 | 14.12 | 348 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.44 | 30 | 14.31 | 482 | 7 | 7 |
2 | 962.64 | -1 | 14.31 | 482 | 7 | 7 |
3 | 1101.76 | 5 | 6.54 | 1916 | 6 | 6 |
4 | 1936.72 | 11 | 8.60 | 3221 | 6 | 6 |
5 | 1924.48 | 31 | 11.27 | 3176 | 6 | 6 |
6 | 1759.08 | 25 | 12.22 | 2949 | 6 | 6 |
7 | 1160.92 | 25 | 12.82 | 2097 | 6 | 6 |
8 | 518.60 | 25 | 13.42 | 1190 | 6 | 7 |
9 | 136.04 | 25 | 14.00 | 583 | 6 | 7 |
10 | 36.20 | 25 | 14.24 | 402 | 6 | 8 |
11 | 0.12 | 181 | 14.12 | 347 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.16 | 28 | 14.31 | 482 | 6 | 6 |
2 | 1039.76 | 1 | 11.07 | 1928 | 6 | 6 |
3 | 1024.24 | 1 | 10.82 | 1892 | 6 | 6 |
4 | 1133.72 | 5 | 6.77 | 2023 | 6 | 6 |
5 | 1941.52 | 11 | 8.64 | 3317 | 6 | 6 |
6 | 1932.36 | 31 | 11.32 | 3152 | 6 | 6 |
7 | 1760.36 | 25 | 12.25 | 2904 | 6 | 6 |
8 | 1334.24 | 25 | 12.72 | 2310 | 6 | 6 |
9 | 483.68 | 25 | 13.50 | 1108 | 6 | 7 |
10 | 135.68 | 25 | 14.03 | 567 | 6 | 7 |
11 | 71.12 | 25 | 14.24 | 444 | 6 | 8 |
12 | 0.08 | 181 | 14.17 | 338 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.40 | 29 | 14.25 | 482 | 6 | 6 |
2 | 969.12 | -1 | 14.25 | 482 | 6 | 6 |
3 | 1120.88 | 5 | 6.92 | 1940 | 6 | 6 |
4 | 1952.64 | 11 | 8.52 | 3310 | 6 | 6 |
5 | 1947.64 | 31 | 11.27 | 3178 | 6 | 6 |
6 | 1759.92 | 25 | 12.26 | 2938 | 6 | 6 |
7 | 1154.84 | 25 | 12.84 | 2065 | 6 | 6 |
8 | 540.60 | 25 | 13.45 | 1197 | 6 | 7 |
9 | 90.40 | 25 | 14.13 | 491 | 6 | 7 |
10 | 48.32 | 25 | 14.25 | 419 | 6 | 8 |
11 | 0.16 | 181 | 14.16 | 346 | 6 | 16 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.68 | 29 | 14.25 | 500 | 6 | 6 |
2 | 1126.04 | 5 | 7.33 | 1928 | 6 | 6 |
3 | 1924.76 | 11 | 9.10 | 3099 | 6 | 6 |
4 | 1912.44 | 30 | 11.21 | 3119 | 6 | 6 |
5 | 1717.56 | 25 | 12.27 | 2862 | 6 | 6 |
6 | 1295.08 | 25 | 12.75 | 2278 | 6 | 6 |
7 | 622.64 | 25 | 13.31 | 1326 | 6 | 7 |
8 | 83.24 | 26 | 14.15 | 454 | 6 | 7 |
9 | 22.08 | 26 | 14.30 | 366 | 6 | 7 |
10 | 0.12 | 181 | 14.11 | 351 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.20 | 29 | 14.31 | 482 | 6 | 6 |
2 | 1124.92 | 5 | 7.48 | 1928 | 6 | 6 |
3 | 1936.32 | 11 | 9.08 | 3160 | 6 | 6 |
4 | 1922.12 | 31 | 11.30 | 3120 | 6 | 6 |
5 | 1719.96 | 25 | 12.29 | 2876 | 6 | 6 |
6 | 1094.48 | 25 | 12.92 | 2004 | 6 | 6 |
7 | 458.72 | 25 | 13.54 | 1078 | 6 | 7 |
8 | 120.80 | 25 | 14.09 | 536 | 6 | 7 |
9 | 12.04 | 25 | 14.33 | 367 | 6 | 7 |
10 | 0.12 | 181 | 14.10 | 352 | 6 | 15 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.00 | 28 | 14.31 | 500 | 6 | 6 |
2 | 1019.16 | 1 | 10.00 | 1839 | 6 | 6 |
3 | 1129.56 | 5 | 7.46 | 1963 | 6 | 6 |
4 | 1903.00 | 11 | 9.17 | 3145 | 6 | 6 |
5 | 1891.32 | 31 | 11.39 | 3078 | 6 | 6 |
6 | 1718.88 | 25 | 12.31 | 2867 | 6 | 6 |
7 | 1112.88 | 25 | 12.88 | 2024 | 6 | 6 |
8 | 489.88 | 25 | 13.50 | 1112 | 6 | 7 |
9 | 129.72 | 25 | 14.09 | 538 | 6 | 7 |
10 | 34.64 | 25 | 14.31 | 371 | 6 | 8 |
11 | 0.00 | 181 | 14.15 | 336 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.36 | 29 | 14.25 | 500 | 6 | 6 |
2 | 974.88 | -1 | 14.25 | 500 | 6 | 6 |
3 | 1134.12 | 5 | 7.10 | 1964 | 6 | 6 |
4 | 1893.40 | 11 | 8.40 | 3110 | 6 | 6 |
5 | 1884.24 | 31 | 11.46 | 3096 | 6 | 6 |
6 | 1722.08 | 25 | 12.37 | 2867 | 6 | 6 |
7 | 1085.56 | 25 | 12.95 | 1972 | 6 | 6 |
8 | 464.72 | 25 | 13.55 | 1072 | 6 | 7 |
9 | 115.56 | 25 | 14.13 | 508 | 6 | 7 |
10 | 27.52 | 25 | 14.36 | 357 | 6 | 7 |
11 | 0.12 | 181 | 14.14 | 345 | 6 | 17 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 108.68 | 29 | 14.31 | 500 | 6 | 6 |
2 | 2003.56 | 35 | 7.48 | 3661 | 6 | 6 |
3 | 1946.24 | 20 | 12.31 | 3171 | 6 | 6 |
4 | 1805.68 | 20 | 12.51 | 2968 | 6 | 6 |
5 | 1624.24 | 20 | 12.66 | 2751 | 6 | 6 |
6 | 1201.08 | 20 | 12.97 | 2160 | 6 | 6 |
7 | 748.16 | 20 | 13.35 | 1477 | 6 | 7 |
8 | 272.96 | 20 | 13.85 | 805 | 6 | 8 |
9 | 61.16 | 21 | 14.26 | 446 | 6 | 7 |
10 | 28.32 | 21 | 14.29 | 400 | 6 | 8 |
11 | 0.12 | 201 | 14.12 | 355 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.32 | 29 | 14.31 | 482 | 6 | 6 |
2 | 2001.40 | 35 | 7.53 | 4347 | 6 | 6 |
3 | 2062.56 | 20 | 12.31 | 3343 | 6 | 6 |
4 | 1939.36 | 20 | 12.48 | 3151 | 6 | 6 |
5 | 1752.80 | 20 | 12.60 | 2937 | 6 | 6 |
6 | 1533.92 | 20 | 12.77 | 2602 | 6 | 6 |
7 | 1352.00 | 20 | 12.89 | 2356 | 6 | 6 |
8 | 607.68 | 20 | 13.49 | 1265 | 6 | 7 |
9 | 160.28 | 21 | 14.06 | 591 | 6 | 7 |
10 | 76.28 | 21 | 14.26 | 466 | 6 | 7 |
11 | 0.08 | 201 | 14.17 | 347 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.64 | 29 | 14.37 | 482 | 6 | 7 |
2 | 2005.48 | 35 | 8.60 | 3803 | 7 | 6 |
3 | 1922.64 | 20 | 12.39 | 3144 | 6 | 6 |
4 | 1764.40 | 20 | 12.56 | 2923 | 6 | 6 |
5 | 1560.64 | 20 | 12.73 | 2664 | 6 | 6 |
6 | 1135.24 | 20 | 13.07 | 2041 | 6 | 6 |
7 | 462.08 | 20 | 13.65 | 1093 | 6 | 7 |
8 | 124.56 | 21 | 14.10 | 557 | 6 | 7 |
9 | 58.84 | 21 | 14.27 | 440 | 6 | 7 |
10 | 0.08 | 201 | 14.16 | 342 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.24 | 28 | 14.37 | 482 | 6 | 7 |
2 | 2002.52 | 35 | 8.88 | 3904 | 6 | 6 |
3 | 1912.56 | 20 | 12.43 | 3202 | 6 | 6 |
4 | 1748.92 | 20 | 12.60 | 2961 | 6 | 6 |
5 | 1538.64 | 20 | 12.78 | 2640 | 6 | 6 |
6 | 1112.96 | 20 | 13.09 | 2037 | 6 | 6 |
7 | 663.32 | 21 | 13.44 | 1360 | 6 | 7 |
8 | 115.52 | 21 | 14.21 | 499 | 6 | 7 |
9 | 60.88 | 21 | 14.32 | 418 | 6 | 7 |
10 | 0.12 | 201 | 14.18 | 345 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.88 | 29 | 14.37 | 500 | 7 | 7 |
2 | 955.72 | -1 | 14.37 | 500 | 7 | 7 |
3 | 2002.64 | 35 | 9.05 | 4067 | 6 | 6 |
4 | 1927.00 | 21 | 12.40 | 3174 | 6 | 6 |
5 | 1790.28 | 20 | 12.64 | 3006 | 6 | 6 |
6 | 1607.08 | 20 | 12.78 | 2722 | 6 | 6 |
7 | 1167.80 | 20 | 13.06 | 2122 | 6 | 7 |
8 | 700.80 | 21 | 13.39 | 1472 | 6 | 7 |
9 | 119.60 | 21 | 14.15 | 539 | 6 | 7 |
10 | 65.72 | 21 | 14.27 | 454 | 6 | 7 |
11 | 12.52 | 21 | 14.39 | 363 | 6 | 8 |
12 | 0.08 | 201 | 14.15 | 348 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.48 | 29 | 14.37 | 500 | 6 | 6 |
2 | 2007.04 | 35 | 10.02 | 3674 | 6 | 6 |
3 | 1878.24 | 20 | 12.52 | 3104 | 6 | 6 |
4 | 1677.00 | 20 | 12.74 | 2812 | 6 | 6 |
5 | 1269.12 | 20 | 13.01 | 2236 | 6 | 6 |
6 | 830.32 | 20 | 13.36 | 1655 | 6 | 6 |
7 | 373.12 | 21 | 13.73 | 978 | 6 | 8 |
8 | 94.68 | 21 | 14.25 | 494 | 6 | 7 |
9 | 50.64 | 21 | 14.33 | 418 | 6 | 7 |
10 | 0.04 | 200 | 14.21 | 348 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 114.56 | 28 | 14.37 | 517 | 6 | 6 |
2 | 2004.20 | 35 | 9.82 | 4103 | 6 | 6 |
3 | 1935.36 | 20 | 12.56 | 3169 | 6 | 6 |
4 | 1771.64 | 20 | 12.70 | 2930 | 6 | 6 |
5 | 1593.92 | 20 | 12.86 | 2691 | 6 | 6 |
6 | 1144.56 | 21 | 13.10 | 2071 | 6 | 6 |
7 | 470.28 | 21 | 13.67 | 1100 | 6 | 7 |
8 | 128.16 | 21 | 14.14 | 533 | 6 | 7 |
9 | 68.24 | 21 | 14.29 | 428 | 6 | 7 |
10 | 0.12 | 201 | 14.18 | 347 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.56 | 29 | 14.43 | 500 | 7 | 7 |
2 | 972.44 | -1 | 14.43 | 500 | 7 | 7 |
3 | 1026.52 | 1 | 12.68 | 1946 | 6 | 6 |
4 | 2010.00 | 35 | 10.95 | 3526 | 6 | 6 |
5 | 1858.64 | 20 | 12.62 | 3071 | 6 | 6 |
6 | 1657.52 | 20 | 12.80 | 2798 | 6 | 6 |
7 | 1243.04 | 21 | 13.06 | 2212 | 6 | 6 |
8 | 592.96 | 21 | 13.59 | 1257 | 6 | 7 |
9 | 169.76 | 21 | 14.08 | 616 | 6 | 8 |
10 | 83.52 | 21 | 14.28 | 474 | 6 | 7 |
11 | 0.16 | 201 | 14.18 | 348 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.48 | 28 | 14.43 | 482 | 7 | 7 |
2 | 2002.56 | 35 | 10.45 | 3828 | 6 | 6 |
3 | 1877.16 | 20 | 12.62 | 3118 | 6 | 6 |
4 | 1718.04 | 20 | 12.80 | 2899 | 6 | 6 |
5 | 1297.88 | 20 | 13.09 | 2285 | 6 | 6 |
6 | 880.76 | 20 | 13.35 | 1709 | 6 | 7 |
7 | 232.28 | 21 | 13.96 | 742 | 6 | 7 |
8 | 110.64 | 21 | 14.24 | 533 | 6 | 7 |
9 | 51.64 | 21 | 14.35 | 432 | 6 | 8 |
10 | 0.12 | 200 | 14.19 | 351 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.24 | 28 | 14.43 | 482 | 6 | 6 |
2 | 2000.52 | 35 | 10.96 | 3646 | 6 | 6 |
3 | 1867.80 | 20 | 12.73 | 3071 | 6 | 6 |
4 | 1684.88 | 20 | 12.82 | 2843 | 6 | 6 |
5 | 1479.00 | 20 | 12.96 | 2577 | 6 | 6 |
6 | 803.48 | 20 | 13.43 | 1604 | 6 | 7 |
7 | 338.52 | 20 | 13.86 | 907 | 6 | 8 |
8 | 90.20 | 21 | 14.28 | 464 | 6 | 7 |
9 | 19.72 | 21 | 14.43 | 368 | 6 | 7 |
10 | 0.20 | 201 | 14.21 | 347 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.40 | 28 | 14.50 | 500 | 6 | 6 |
2 | 1023.64 | 1 | 12.62 | 1982 | 6 | 6 |
3 | 2002.88 | 35 | 11.30 | 3623 | 6 | 6 |
4 | 1861.64 | 20 | 12.71 | 3088 | 6 | 6 |
5 | 1677.24 | 20 | 12.86 | 2830 | 6 | 6 |
6 | 1467.72 | 20 | 13.01 | 2533 | 6 | 6 |
7 | 771.48 | 20 | 13.48 | 1539 | 6 | 7 |
8 | 307.84 | 21 | 13.89 | 849 | 6 | 8 |
9 | 73.60 | 21 | 14.32 | 432 | 6 | 7 |
10 | 34.96 | 21 | 14.39 | 369 | 6 | 7 |
11 | 0.04 | 201 | 14.21 | 328 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.60 | 28 | 14.50 | 482 | 6 | 6 |
2 | 2003.84 | 35 | 11.67 | 3549 | 6 | 6 |
3 | 1857.00 | 20 | 12.77 | 3122 | 6 | 6 |
4 | 1650.00 | 20 | 12.92 | 2769 | 6 | 6 |
5 | 1215.92 | 21 | 13.16 | 2168 | 6 | 6 |
6 | 770.24 | 20 | 13.51 | 1532 | 6 | 7 |
7 | 296.68 | 21 | 13.93 | 851 | 6 | 8 |
8 | 70.16 | 21 | 14.35 | 448 | 6 | 7 |
9 | 32.56 | 21 | 14.37 | 396 | 6 | 8 |
10 | 0.12 | 201 | 14.20 | 343 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.84 | 35 | 14.31 | 517 | 6 | 6 |
2 | 2004.92 | 35 | 11.54 | 3548 | 6 | 6 |
3 | 1862.40 | 20 | 12.82 | 3057 | 6 | 6 |
4 | 1657.40 | 20 | 12.94 | 2812 | 6 | 6 |
5 | 1207.32 | 20 | 13.19 | 2175 | 6 | 6 |
6 | 756.88 | 20 | 13.52 | 1537 | 6 | 7 |
7 | 151.44 | 21 | 14.18 | 605 | 6 | 7 |
8 | 76.68 | 21 | 14.36 | 470 | 6 | 7 |
9 | 16.68 | 21 | 14.45 | 375 | 6 | 7 |
10 | 0.20 | 201 | 14.18 | 350 | 6 | 27 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 110.44 | 35 | 14.43 | 500 | 6 | 6 |
2 | 1995.92 | 36 | 11.93 | 3389 | 6 | 6 |
3 | 1803.36 | 21 | 12.83 | 3023 | 6 | 6 |
4 | 1586.88 | 21 | 12.96 | 2713 | 6 | 6 |
5 | 1134.28 | 21 | 13.26 | 2089 | 6 | 6 |
6 | 420.60 | 21 | 13.85 | 1039 | 6 | 7 |
7 | 99.40 | 21 | 14.31 | 513 | 6 | 7 |
8 | 47.20 | 21 | 14.40 | 426 | 6 | 8 |
9 | 0.12 | 201 | 14.24 | 347 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 1101.00 | 9 | 13.81 | 2035 | 6 | 6 |
2 | 1181.00 | 8 | 13.75 | 2178 | 6 | 6 |
3 | 1238.24 | 6 | 13.87 | 2214 | 6 | 6 |
4 | 1272.08 | 3 | 14.00 | 2303 | 6 | 6 |
5 | 1272.64 | 7 | 13.81 | 2303 | 6 | 6 |
6 | 1068.24 | 2 | 14.18 | 2035 | 6 | 6 |
7 | 2003.32 | 36 | 11.54 | 3595 | 6 | 6 |
8 | 1864.56 | 21 | 12.80 | 3096 | 6 | 6 |
9 | 1663.52 | 21 | 12.94 | 2785 | 6 | 6 |
10 | 1036.00 | 21 | 13.33 | 1910 | 6 | 7 |
11 | 602.36 | 21 | 13.74 | 1267 | 6 | 7 |
12 | 154.44 | 21 | 14.24 | 581 | 6 | 7 |
13 | 33.92 | 21 | 14.47 | 388 | 6 | 7 |
14 | 0.08 | 201 | 14.20 | 352 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.60 | 28 | 14.50 | 500 | 6 | 6 |
2 | 2002.60 | 36 | 11.84 | 3513 | 6 | 6 |
3 | 1855.36 | 21 | 12.84 | 3088 | 6 | 6 |
4 | 1643.84 | 21 | 12.96 | 2832 | 6 | 6 |
5 | 1194.56 | 21 | 13.24 | 2172 | 6 | 6 |
6 | 486.68 | 21 | 13.81 | 1156 | 6 | 7 |
7 | 119.24 | 20 | 14.34 | 550 | 6 | 7 |
8 | 59.88 | 20 | 14.42 | 450 | 6 | 7 |
9 | 27.72 | 20 | 14.44 | 389 | 6 | 7 |
10 | 0.12 | 200 | 14.23 | 341 | 6 | 25 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.04 | 28 | 14.50 | 500 | 6 | 6 |
2 | 2006.64 | 36 | 11.77 | 3606 | 6 | 6 |
3 | 1846.28 | 20 | 12.87 | 3131 | 6 | 6 |
4 | 1645.52 | 20 | 13.00 | 2816 | 6 | 6 |
5 | 1208.52 | 20 | 13.27 | 2187 | 6 | 6 |
6 | 767.36 | 20 | 13.60 | 1575 | 6 | 7 |
7 | 306.68 | 20 | 14.06 | 865 | 6 | 7 |
8 | 60.88 | 20 | 14.44 | 461 | 6 | 7 |
9 | 34.80 | 21 | 14.44 | 412 | 6 | 7 |
10 | 0.00 | 201 | 14.22 | 354 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 1224.24 | 9 | 13.75 | 2214 | 6 | 6 |
2 | 1290.36 | 7 | 13.75 | 2303 | 6 | 6 |
3 | 1334.52 | 4 | 13.87 | 2339 | 6 | 6 |
4 | 1433.20 | 6 | 13.87 | 2500 | 6 | 6 |
5 | 1261.64 | 2 | 14.18 | 2321 | 6 | 6 |
6 | 2003.12 | 36 | 11.52 | 3803 | 6 | 6 |
7 | 1894.88 | 21 | 12.85 | 3124 | 6 | 6 |
8 | 1722.12 | 21 | 12.93 | 2896 | 6 | 6 |
9 | 1297.84 | 21 | 13.21 | 2335 | 6 | 6 |
10 | 619.60 | 21 | 13.73 | 1331 | 6 | 7 |
11 | 164.28 | 21 | 14.27 | 640 | 6 | 7 |
12 | 39.32 | 21 | 14.48 | 420 | 6 | 7 |
13 | 18.12 | 21 | 14.43 | 394 | 6 | 7 |
14 | 0.08 | 201 | 14.21 | 356 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.32 | 15 | 14.68 | 500 | 6 | 6 |
2 | 2001.88 | 36 | 12.59 | 3365 | 6 | 6 |
3 | 1815.20 | 20 | 12.95 | 3044 | 6 | 6 |
4 | 1610.56 | 20 | 13.06 | 2771 | 6 | 6 |
5 | 918.00 | 20 | 13.53 | 1800 | 6 | 7 |
6 | 483.00 | 20 | 13.94 | 1148 | 6 | 7 |
7 | 112.00 | 20 | 14.38 | 550 | 6 | 7 |
8 | 54.12 | 20 | 14.46 | 450 | 6 | 7 |
9 | 0.16 | 200 | 14.24 | 356 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.44 | 14 | 14.68 | 517 | 6 | 6 |
2 | 2002.48 | 36 | 12.56 | 3302 | 6 | 6 |
3 | 1834.64 | 20 | 12.95 | 3066 | 6 | 6 |
4 | 1617.88 | 20 | 13.05 | 2769 | 6 | 6 |
5 | 1164.48 | 20 | 13.34 | 2140 | 6 | 6 |
6 | 488.92 | 20 | 13.94 | 1160 | 6 | 7 |
7 | 113.16 | 20 | 14.40 | 553 | 6 | 7 |
8 | 29.56 | 20 | 14.51 | 416 | 6 | 7 |
9 | 0.16 | 201 | 14.21 | 359 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.72 | 14 | 14.68 | 517 | 6 | 6 |
2 | 2003.00 | 36 | 12.74 | 3239 | 6 | 6 |
3 | 1828.24 | 20 | 12.96 | 3035 | 6 | 6 |
4 | 1406.52 | 20 | 13.20 | 2472 | 6 | 6 |
5 | 974.12 | 20 | 13.51 | 1867 | 6 | 7 |
6 | 517.36 | 20 | 13.88 | 1214 | 6 | 8 |
7 | 121.00 | 20 | 14.38 | 573 | 6 | 7 |
8 | 27.48 | 20 | 14.53 | 412 | 6 | 7 |
9 | 0.08 | 201 | 14.22 | 362 | 6 | 21 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.00 | 5 | 14.81 | 517 | 6 | 6 |
2 | 2075.56 | 36 | 12.73 | 3367 | 6 | 6 |
3 | 1880.32 | 20 | 12.93 | 3120 | 6 | 6 |
4 | 1459.00 | 20 | 13.16 | 2557 | 6 | 6 |
5 | 1008.92 | 20 | 13.50 | 1923 | 6 | 7 |
6 | 333.40 | 20 | 14.11 | 925 | 6 | 7 |
7 | 81.00 | 20 | 14.47 | 508 | 6 | 7 |
8 | 41.44 | 20 | 14.48 | 446 | 6 | 7 |
9 | 0.08 | 201 | 14.25 | 366 | 6 | 20 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.56 | 5 | 14.87 | 517 | 6 | 6 |
2 | 2082.68 | 36 | 12.60 | 3478 | 6 | 6 |
3 | 1898.36 | 20 | 12.91 | 3193 | 6 | 6 |
4 | 1474.44 | 20 | 13.19 | 2575 | 6 | 6 |
5 | 822.44 | 20 | 13.64 | 1649 | 6 | 7 |
6 | 395.76 | 20 | 14.06 | 1030 | 6 | 8 |
7 | 91.44 | 20 | 14.45 | 528 | 6 | 7 |
8 | 45.84 | 20 | 14.49 | 450 | 6 | 7 |
9 | 0.12 | 201 | 14.23 | 368 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 100.00 | 5 | 14.81 | 517 | 6 | 6 |
2 | 2061.36 | 36 | 12.62 | 3442 | 6 | 6 |
3 | 1849.28 | 20 | 12.96 | 3113 | 6 | 6 |
4 | 1414.64 | 20 | 13.22 | 2501 | 6 | 6 |
5 | 984.56 | 20 | 13.52 | 1879 | 6 | 7 |
6 | 523.76 | 20 | 13.91 | 1207 | 6 | 7 |
7 | 124.32 | 20 | 14.41 | 591 | 6 | 7 |
8 | 24.84 | 20 | 14.56 | 419 | 6 | 7 |
9 | 0.12 | 201 | 14.22 | 376 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 103.44 | 3 | 14.87 | 517 | 6 | 6 |
2 | 2083.60 | 36 | 12.64 | 3456 | 6 | 6 |
3 | 1897.00 | 20 | 12.91 | 3196 | 6 | 6 |
4 | 1468.44 | 20 | 13.19 | 2564 | 6 | 6 |
5 | 838.68 | 20 | 13.63 | 1696 | 6 | 6 |
6 | 404.68 | 20 | 14.06 | 1028 | 6 | 7 |
7 | 93.36 | 20 | 14.49 | 528 | 6 | 7 |
8 | 19.60 | 20 | 14.58 | 412 | 6 | 7 |
9 | 0.16 | 201 | 14.26 | 371 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.84 | 3 | 14.87 | 517 | 6 | 6 |
2 | 2093.72 | 36 | 12.58 | 3473 | 6 | 6 |
3 | 1917.52 | 20 | 12.88 | 3234 | 6 | 6 |
4 | 1486.52 | 20 | 13.18 | 2597 | 6 | 6 |
5 | 1043.56 | 20 | 13.48 | 1979 | 6 | 6 |
6 | 575.24 | 20 | 13.86 | 1307 | 6 | 7 |
7 | 87.44 | 20 | 14.48 | 523 | 6 | 7 |
8 | 42.84 | 20 | 14.53 | 448 | 6 | 7 |
9 | 0.04 | 201 | 14.26 | 372 | 6 | 19 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.00 | 3 | 14.93 | 446 | 6 | 6 |
2 | 2064.08 | 36 | 12.77 | 3364 | 6 | 6 |
3 | 1862.76 | 20 | 12.93 | 3182 | 6 | 6 |
4 | 1410.68 | 20 | 13.22 | 2521 | 6 | 6 |
5 | 980.80 | 20 | 13.51 | 1921 | 6 | 6 |
6 | 319.36 | 20 | 14.17 | 928 | 6 | 7 |
7 | 67.24 | 20 | 14.50 | 506 | 6 | 7 |
8 | 32.84 | 20 | 14.53 | 441 | 6 | 7 |
9 | 0.12 | 201 | 14.25 | 378 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 101.92 | 3 | 14.93 | 446 | 6 | 6 |
2 | 2093.28 | 30 | 14.52 | 411 | 6 | 6 |
3 | 2093.72 | 35 | 12.38 | 3432 | 6 | 6 |
4 | 1924.88 | 20 | 12.94 | 3158 | 6 | 6 |
5 | 1713.72 | 20 | 13.06 | 2845 | 6 | 6 |
6 | 1025.24 | 21 | 13.48 | 1890 | 6 | 6 |
7 | 364.88 | 21 | 14.15 | 902 | 6 | 7 |
8 | 69.48 | 21 | 14.58 | 422 | 6 | 7 |
9 | 31.88 | 21 | 14.60 | 357 | 6 | 7 |
10 | 0.00 | 201 | 14.38 | 303 | 6 | 26 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.16 | 2 | 15.00 | 446 | 6 | 6 |
2 | 1980.48 | 1 | 14.06 | 3232 | 6 | 6 |
3 | 2089.00 | 30 | 14.54 | 401 | 6 | 6 |
4 | 2088.96 | 35 | 12.58 | 3350 | 6 | 6 |
5 | 1892.60 | 20 | 12.95 | 3102 | 6 | 6 |
6 | 1463.16 | 21 | 13.21 | 2475 | 6 | 6 |
7 | 1003.12 | 21 | 13.51 | 1847 | 6 | 6 |
8 | 316.52 | 21 | 14.18 | 841 | 6 | 7 |
9 | 66.44 | 21 | 14.59 | 414 | 6 | 7 |
10 | 0.00 | 201 | 14.37 | 303 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 102.96 | 4 | 15.00 | 446 | 6 | 6 |
2 | 1921.24 | -1 | 15.00 | 446 | 6 | 6 |
3 | 2087.96 | 30 | 14.58 | 408 | 6 | 6 |
4 | 2087.64 | 35 | 12.58 | 3339 | 6 | 6 |
5 | 1896.76 | 21 | 12.93 | 3096 | 6 | 6 |
6 | 1689.32 | 21 | 13.03 | 2816 | 6 | 6 |
7 | 968.44 | 21 | 13.54 | 1801 | 6 | 7 |
8 | 297.80 | 21 | 14.21 | 803 | 6 | 7 |
9 | 63.72 | 20 | 14.62 | 403 | 6 | 7 |
10 | 29.52 | 20 | 14.62 | 341 | 6 | 7 |
11 | 0.12 | 201 | 14.36 | 304 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.08 | 2 | 15.06 | 446 | 6 | 6 |
2 | 2020.56 | 2 | 14.12 | 3303 | 6 | 6 |
3 | 2017.88 | 30 | 14.59 | 411 | 6 | 6 |
4 | 2018.48 | 35 | 12.59 | 3219 | 6 | 6 |
5 | 1841.08 | 21 | 12.94 | 3019 | 6 | 6 |
6 | 1410.36 | 21 | 13.23 | 2420 | 6 | 6 |
7 | 734.76 | 21 | 13.73 | 1444 | 6 | 7 |
8 | 290.20 | 21 | 14.21 | 793 | 6 | 8 |
9 | 64.12 | 20 | 14.61 | 405 | 6 | 7 |
10 | 0.12 | 201 | 14.39 | 301 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.24 | 6 | 15.00 | 446 | 6 | 6 |
2 | 1880.88 | -1 | 15.00 | 446 | 6 | 6 |
3 | 1835.48 | -2 | 15.00 | 446 | 6 | 6 |
4 | 1898.20 | 30 | 14.61 | 419 | 6 | 6 |
5 | 1899.72 | 35 | 12.77 | 3086 | 6 | 6 |
6 | 1706.36 | 21 | 13.04 | 2827 | 6 | 6 |
7 | 1510.64 | 21 | 13.18 | 2547 | 6 | 6 |
8 | 837.52 | 21 | 13.66 | 1589 | 6 | 6 |
9 | 188.72 | 21 | 14.35 | 634 | 6 | 7 |
10 | 43.96 | 21 | 14.64 | 382 | 6 | 7 |
11 | 21.16 | 21 | 14.62 | 339 | 6 | 7 |
12 | 0.04 | 200 | 14.38 | 303 | 6 | 24 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2069.08 | 3 | 13.75 | 3357 | 6 | 6 |
2 | 2051.68 | 3 | 13.87 | 3357 | 6 | 6 |
3 | 2113.64 | 36 | 12.67 | 3462 | 6 | 6 |
4 | 1904.48 | 20 | 12.99 | 3162 | 6 | 6 |
5 | 1703.96 | 20 | 13.11 | 2843 | 6 | 6 |
6 | 844.20 | 20 | 13.68 | 1602 | 6 | 6 |
7 | 416.00 | 20 | 14.07 | 1001 | 6 | 6 |
8 | 104.72 | 20 | 14.59 | 477 | 6 | 6 |
9 | 54.88 | 20 | 14.67 | 392 | 6 | 6 |
10 | 0.08 | 201 | 14.44 | 301 | 6 | 22 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 1834.84 | -2 | 0.00 | 0 | 6 | 6 |
2 | 1836.92 | -2 | 0.00 | 0 | 6 | 6 |
3 | 2104.64 | 36 | 12.72 | 3430 | 6 | 6 |
4 | 1895.12 | 20 | 12.98 | 3100 | 6 | 6 |
5 | 1451.40 | 20 | 13.26 | 2488 | 6 | 6 |
6 | 1245.48 | 20 | 13.38 | 2202 | 6 | 6 |
7 | 529.88 | 20 | 13.94 | 1184 | 6 | 6 |
8 | 132.36 | 20 | 14.52 | 532 | 6 | 6 |
9 | 38.52 | 20 | 14.69 | 366 | 6 | 6 |
10 | -0.04 | 201 | 14.39 | 303 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 111.96 | 21 | 14.81 | 464 | 6 | 6 |
2 | 1373.76 | -11 | 14.81 | 464 | 6 | 6 |
3 | 1647.36 | -6 | 14.81 | 464 | 6 | 6 |
4 | 1848.48 | 30 | 14.70 | 419 | 6 | 6 |
5 | 1850.52 | 35 | 12.77 | 3026 | 6 | 6 |
6 | 1705.96 | 20 | 13.06 | 2847 | 6 | 6 |
7 | 1287.24 | 21 | 13.30 | 2243 | 6 | 6 |
8 | 853.00 | 21 | 13.64 | 1636 | 6 | 6 |
9 | 204.80 | 21 | 14.35 | 656 | 6 | 6 |
10 | 101.84 | 21 | 14.54 | 474 | 6 | 6 |
11 | 46.92 | 21 | 14.64 | 378 | 6 | 7 |
12 | 0.08 | 201 | 14.40 | 302 | 6 | 23 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 116.76 | 21 | 14.81 | 464 | 6 | 6 |
2 | 1047.60 | 4 | 14.37 | 1928 | 6 | 6 |
3 | 1222.92 | 6 | 14.18 | 2178 | 6 | 6 |
4 | 1108.40 | 3 | 14.37 | 2071 | 6 | 6 |
5 | 1332.44 | 8 | 13.81 | 2392 | 6 | 6 |
6 | 1325.16 | 8 | 13.93 | 2285 | 6 | 6 |
7 | 1308.64 | 8 | 13.93 | 2303 | 6 | 6 |
8 | 1329.24 | 8 | 13.87 | 2357 | 6 | 6 |
9 | 1308.32 | 8 | 13.87 | 2267 | 6 | 6 |
10 | 1412.56 | 10 | 13.62 | 2410 | 6 | 6 |
11 | 1323.12 | 8 | 13.87 | 2303 | 6 | 6 |
12 | 1341.76 | 9 | 13.81 | 2339 | 6 | 6 |
13 | 1324.68 | 8 | 13.81 | 2321 | 6 | 6 |
14 | 1332.88 | 8 | 13.81 | 2357 | 6 | 6 |
15 | 1372.96 | 9 | 13.68 | 2357 | 6 | 6 |
16 | 1329.76 | 8 | 13.81 | 2321 | 6 | 6 |
17 | 1370.00 | 9 | 13.75 | 2339 | 6 | 6 |
18 | 1316.72 | 8 | 13.81 | 2303 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.88 | 30 | 14.68 | 428 | 6 | 6 |
2 | 955.36 | -1 | 14.68 | 428 | 6 | 6 |
3 | 1040.48 | 1 | 14.43 | 1964 | 6 | 6 |
4 | 1406.40 | 10 | 13.68 | 2446 | 6 | 6 |
5 | 1308.80 | 8 | 13.93 | 2250 | 6 | 6 |
6 | 1319.72 | 8 | 13.93 | 2303 | 6 | 6 |
7 | 1313.08 | 8 | 13.93 | 2267 | 6 | 6 |
8 | 1327.96 | 8 | 13.87 | 2321 | 6 | 6 |
9 | 1362.64 | 9 | 13.75 | 2321 | 6 | 6 |
10 | 1319.68 | 8 | 13.87 | 2357 | 6 | 6 |
11 | 1325.16 | 8 | 13.87 | 2339 | 6 | 6 |
12 | 1380.68 | 10 | 13.62 | 2410 | 6 | 6 |
13 | 1325.36 | 8 | 13.93 | 2267 | 6 | 6 |
14 | 1363.96 | 9 | 13.75 | 2321 | 6 | 6 |
15 | 1328.88 | 8 | 13.87 | 2303 | 6 | 6 |
16 | 1354.48 | 9 | 13.68 | 2375 | 6 | 6 |
17 | 1370.36 | 9 | 13.75 | 2339 | 6 | 6 |
18 | 1391.20 | 10 | 13.56 | 2428 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 104.48 | 29 | 14.68 | 446 | 6 | 6 |
2 | 1046.68 | 1 | 14.43 | 1982 | 6 | 6 |
3 | 1363.64 | 9 | 13.81 | 2410 | 6 | 6 |
4 | 1347.08 | 9 | 13.81 | 2375 | 6 | 6 |
5 | 1342.76 | 9 | 13.81 | 2357 | 6 | 6 |
6 | 1409.12 | 10 | 13.62 | 2464 | 6 | 6 |
7 | 1396.96 | 10 | 13.75 | 2375 | 6 | 6 |
8 | 1363.36 | 9 | 13.75 | 2357 | 6 | 6 |
9 | 1340.84 | 9 | 13.81 | 2321 | 6 | 6 |
10 | 1370.60 | 9 | 13.68 | 2375 | 6 | 6 |
11 | 1356.84 | 9 | 13.75 | 2339 | 6 | 6 |
12 | 1359.16 | 9 | 13.75 | 2357 | 6 | 6 |
13 | 1409.72 | 10 | 13.62 | 2392 | 6 | 6 |
14 | 1325.76 | 8 | 13.81 | 2321 | 6 | 6 |
15 | 1308.80 | 8 | 13.87 | 2267 | 6 | 6 |
16 | 1302.48 | 8 | 13.87 | 2267 | 6 | 6 |
17 | 1302.60 | 8 | 13.81 | 2285 | 6 | 6 |
18 | 1307.48 | 8 | 13.81 | 2285 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 109.16 | 29 | 14.68 | 446 | 6 | 6 |
2 | 940.36 | -1 | 14.68 | 446 | 6 | 6 |
3 | 1024.00 | 1 | 14.50 | 1928 | 6 | 6 |
4 | 1340.44 | 9 | 13.87 | 2357 | 6 | 6 |
5 | 1303.40 | 8 | 13.93 | 2267 | 6 | 6 |
6 | 1416.64 | 11 | 13.62 | 2428 | 6 | 6 |
7 | 1339.68 | 9 | 13.81 | 2303 | 6 | 6 |
8 | 1322.56 | 8 | 13.87 | 2303 | 6 | 6 |
9 | 1367.00 | 9 | 13.75 | 2357 | 6 | 6 |
10 | 1317.60 | 8 | 13.87 | 2303 | 6 | 6 |
11 | 1347.84 | 9 | 13.87 | 2339 | 6 | 6 |
12 | 1308.76 | 8 | 13.93 | 2232 | 6 | 6 |
13 | 1347.56 | 9 | 13.75 | 2303 | 6 | 6 |
14 | 1320.48 | 8 | 13.87 | 2285 | 6 | 6 |
15 | 1341.52 | 9 | 13.75 | 2339 | 6 | 6 |
16 | 1308.48 | 8 | 13.87 | 2285 | 6 | 6 |
17 | 1304.36 | 8 | 13.81 | 2250 | 6 | 6 |
18 | 2005.16 | 70 | 12.25 | 3271 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 113.32 | 29 | 14.62 | 464 | 6 | 6 |
2 | 958.56 | -1 | 14.62 | 464 | 6 | 6 |
3 | 1059.20 | 2 | 14.43 | 2000 | 6 | 6 |
4 | 1334.24 | 8 | 13.87 | 2303 | 6 | 6 |
5 | 1328.76 | 8 | 13.81 | 2267 | 6 | 6 |
6 | 1302.04 | 8 | 13.87 | 2250 | 6 | 6 |
7 | 1301.56 | 8 | 13.93 | 2250 | 6 | 6 |
8 | 1385.92 | 10 | 13.68 | 2392 | 6 | 6 |
9 | 1319.92 | 8 | 13.87 | 2232 | 6 | 6 |
10 | 1357.00 | 9 | 13.81 | 2303 | 6 | 6 |
11 | 1327.52 | 8 | 13.81 | 2285 | 6 | 6 |
12 | 1315.44 | 8 | 13.87 | 2267 | 6 | 6 |
13 | 1318.76 | 8 | 13.81 | 2303 | 6 | 6 |
14 | 1388.28 | 10 | 13.68 | 2375 | 6 | 6 |
15 | 1319.76 | 8 | 13.81 | 2303 | 6 | 6 |
16 | 1324.56 | 8 | 13.87 | 2232 | 6 | 6 |
17 | 1335.48 | 9 | 13.75 | 2321 | 6 | 6 |
18 | 2004.00 | 70 | 12.14 | 3280 | 6 | 6 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.56 | 30 | 14.62 | 446 | 6 | 6 |
2 | 868.08 | -3 | 14.62 | 446 | 6 | 6 |
3 | 1510.64 | 70 | 12.74 | 2558 | 6 | 6 |
4 | 1037.32 | 25 | 13.28 | 1881 | 6 | 6 |
5 | 308.44 | 25 | 14.04 | 840 | 6 | 7 |
6 | 73.84 | 25 | 14.53 | 426 | 6 | 7 |
7 | 0.12 | 251 | 14.25 | 303 | 6 | 32 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 105.68 | 24 | 14.68 | 446 | 6 | 6 |
2 | 1054.12 | 3 | 14.31 | 1964 | 6 | 6 |
3 | 1058.88 | 2 | 14.43 | 2000 | 6 | 6 |
4 | 1064.64 | 2 | 14.37 | 2000 | 6 | 6 |
5 | 1511.08 | 70 | 12.69 | 2557 | 6 | 6 |
6 | 1028.44 | 25 | 13.25 | 1887 | 6 | 6 |
7 | 174.24 | 25 | 14.29 | 612 | 6 | 6 |
8 | 82.64 | 25 | 14.50 | 437 | 6 | 7 |
9 | 0.16 | 251 | 14.24 | 302 | 6 | 28 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 107.56 | 29 | 14.56 | 446 | 6 | 6 |
2 | 807.36 | -4 | 14.56 | 446 | 6 | 6 |
3 | 1502.52 | 70 | 12.63 | 2544 | 6 | 6 |
4 | 818.68 | 25 | 13.38 | 1578 | 6 | 6 |
5 | 351.12 | 25 | 13.91 | 894 | 6 | 6 |
6 | 65.40 | 25 | 14.49 | 411 | 6 | 7 |
7 | 0.20 | 251 | 14.20 | 304 | 6 | 30 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 106.36 | 29 | 14.56 | 446 | 7 | 7 |
2 | 797.24 | -4 | 14.56 | 446 | 7 | 7 |
3 | 965.64 | -1 | 14.56 | 446 | 7 | 7 |
4 | 1022.48 | 71 | 12.86 | 1861 | 7 | 6 |
5 | 119.76 | 25 | 14.29 | 520 | 6 | 6 |
6 | 56.96 | 25 | 14.42 | 411 | 6 | 6 |
7 | 0.12 | 250 | 14.19 | 311 | 6 | 42 |
Pump Count | Pressure (db) | Time (s) | Voltage (V) | Current (ma) | Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 79.40 | 70 | 14.25 | 406 | 167 | 7 |
2 | 88.24 | 25 | 14.49 | 417 | 7 | 7 |
3 | 51.80 | 25 | 14.59 | 367 | 7 | 7 |
4 | 0.12 | 250 | 14.45 | 283 | 7 | 28 |