SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8703 WMO= 5905718


Cycle 233 GMT 19/12/2024 18:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 34 14.84 438 2 2
2 12 1158.28 2 15.00 2017 2 2
3 7 2005.00 32 14.60 2928 2 2
4 13 1678.00 18 14.59 2573 2 3
5 13 1162.44 18 14.61 1937 2 3
6 13 502.08 18 14.75 1066 2 3
7 13 163.72 18 14.85 573 2 3
8 13 55.12 18 14.88 403 2 3
9 8 0.08 175 14.86 301 2 9

Cycle 232 GMT 9/12/2024 20:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 34 14.84 448 2 2
2 12 1172.96 2 15.00 2045 2 2
3 7 2004.36 31 14.60 2927 2 2
4 13 1670.84 18 14.59 2558 2 3
5 13 1027.60 18 14.63 1760 2 4
6 13 540.72 18 14.73 1122 2 5
7 13 195.28 18 14.83 619 2 3
8 13 52.32 18 14.88 394 2 3
9 8 0.16 175 14.86 302 2 9

Cycle 231 GMT 29/11/2024 22:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 34 14.84 449 2 2
2 12 1172.52 2 15.01 2029 2 2
3 7 2004.48 31 14.61 2932 2 3
4 13 1693.00 18 14.59 2603 2 3
5 13 1165.68 18 14.60 1948 2 3
6 13 493.56 18 14.75 1054 2 5
7 13 177.04 18 14.84 593 2 3
8 13 92.48 18 14.87 455 2 3
9 8 0.12 175 14.86 300 2 9

Cycle 230 GMT 20/11/2024 0:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 34 14.84 435 2 2
2 12 1183.44 2 15.01 2039 2 2
3 7 2007.88 31 14.62 2930 2 3
4 13 1550.52 18 14.60 2418 2 3
5 13 1067.72 18 14.63 1814 2 3
6 13 575.84 18 14.72 1166 2 4
7 13 144.84 18 14.86 542 2 3
8 13 82.92 18 14.87 434 2 3
9 8 0.08 175 14.87 294 2 8

Cycle 229 GMT 10/11/2024 2:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 34 14.84 431 2 2
2 12 1183.80 2 15.00 2049 2 2
3 7 2011.96 31 14.60 2938 2 2
4 13 1699.76 18 14.58 2589 2 3
5 13 1042.76 18 14.63 1785 2 3
6 13 544.84 18 14.73 1123 2 4
7 13 129.48 18 14.87 513 2 3
8 13 72.68 18 14.88 423 2 3
9 8 0.12 175 14.86 296 2 9

Cycle 228 GMT 31/10/2024 4:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 34 14.85 435 2 2
2 12 1160.56 2 15.00 2009 2 2
3 7 2009.88 31 14.61 2944 2 3
4 13 1690.52 18 14.60 2580 2 3
5 13 1041.88 18 14.64 1785 2 3
6 13 552.64 18 14.73 1131 2 4
7 13 129.48 18 14.86 511 2 3
8 13 69.80 18 14.87 419 2 3
9 8 0.12 175 14.86 298 2 8

Cycle 227 GMT 21/10/2024 6:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 34 14.84 429 2 2
2 12 1164.92 2 15.01 2022 2 2
3 7 2009.24 31 14.61 2935 2 3
4 13 1546.92 18 14.61 2416 2 3
5 13 1222.64 18 14.60 2018 2 3
6 13 571.64 18 14.72 1159 2 4
7 13 140.72 18 14.86 530 2 3
8 13 79.64 18 14.87 435 2 3
9 8 0.08 175 14.87 298 2 9

Cycle 226 GMT 11/10/2024 8:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 34 14.85 437 2 2
2 12 1173.72 2 15.01 2030 2 2
3 7 2002.88 31 14.62 2936 2 3
4 13 1523.48 18 14.62 2384 2 3
5 13 1055.08 18 14.63 1803 2 3
6 13 539.76 18 14.73 1114 2 4
7 13 127.48 18 14.87 509 2 3
8 13 78.04 18 14.87 430 2 3
9 8 0.08 175 14.87 295 2 11

Cycle 225 GMT 1/10/2024 10: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 34 14.83 450 2 2
2 12 1180.88 2 15.00 2049 2 2
3 7 2012.96 31 14.61 2947 2 3
4 13 1699.68 18 14.60 2592 2 3
5 13 1203.88 18 14.60 1994 2 3
6 13 531.04 18 14.74 1107 2 4
7 13 189.20 18 14.84 609 2 3
8 13 72.64 18 14.88 423 2 3
9 8 0.08 175 14.87 296 2 8

Cycle 224 GMT 21/ 9/2024 11:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 33 14.84 435 2 2
2 12 1170.64 2 15.00 2010 2 2
3 7 2005.72 31 14.61 2934 2 3
4 13 1691.04 18 14.59 2585 2 3
5 13 1179.24 18 14.61 1958 2 3
6 13 540.60 18 14.73 1117 2 4
7 13 187.12 18 14.84 609 2 3
8 13 69.36 18 14.88 418 2 3
9 8 0.08 175 14.86 300 2 9

Cycle 223 GMT 11/ 9/2024 13:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 34 14.84 449 2 2
2 12 1153.40 2 15.02 2006 2 2
3 7 1987.40 31 14.62 2924 2 3
4 13 1657.60 18 14.60 2557 2 3
5 13 1167.40 18 14.61 1938 2 4
6 13 639.00 18 14.71 1251 2 4
7 13 158.60 18 14.85 561 2 3
8 13 87.12 18 14.87 445 2 3
9 8 0.04 175 14.86 297 2 11

Cycle 222 GMT 1/ 9/2024 12:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 34 14.84 448 2 2
2 12 1135.04 2 15.01 1989 2 2
3 7 2006.20 31 14.62 2944 2 3
4 13 1669.28 18 14.60 2565 2 3
5 13 1322.28 18 14.60 2136 2 3
6 13 622.04 18 14.71 1232 2 4
7 13 155.20 18 14.85 556 2 3
8 13 89.60 18 14.87 450 2 3
9 8 0.16 175 14.87 298 2 9

Cycle 221 GMT 22/ 8/2024 14:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 34 14.83 437 2 2
2 12 1165.20 2 15.00 2029 2 2
3 7 2003.36 31 14.62 2938 2 3
4 13 1687.24 18 14.60 2585 2 3
5 13 1175.44 18 14.61 1946 2 3
6 13 648.80 18 14.70 1266 2 4
7 13 162.00 18 14.85 568 2 3
8 13 52.24 18 14.88 393 2 3
9 8 0.12 175 14.87 297 2 11

Cycle 220 GMT 12/ 8/2024 16:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 34 14.84 434 2 2
2 12 1159.16 2 15.00 2015 2 2
3 7 1977.52 31 14.61 2902 2 3
4 13 1655.84 18 14.60 2549 2 3
5 13 984.36 18 14.65 1703 2 4
6 13 506.52 18 14.74 1073 2 4
7 13 168.48 18 14.84 583 2 3
8 13 56.64 18 14.87 396 2 3
9 13 18.52 18 14.88 341 2 3
10 8 0.00 175 14.85 303 2 9

Cycle 219 GMT 2/ 8/2024 16:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 33 14.83 439 2 2
2 12 1191.64 2 15.00 2054 2 2
3 7 1958.40 31 14.63 2879 2 3
4 13 1638.52 18 14.61 2526 2 3
5 13 1136.16 18 14.63 1906 2 3
6 13 502.96 18 14.75 1064 2 4
7 13 169.76 18 14.84 586 2 3
8 13 64.64 18 14.88 408 2 3
9 8 0.16 175 14.86 298 2 8

Cycle 218 GMT 23/ 7/2024 15:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 33 14.84 443 2 2
2 12 1160.40 2 15.01 2004 2 2
3 7 1951.48 31 14.62 2874 2 3
4 13 1655.84 18 14.61 2548 2 3
5 13 1140.36 18 14.62 1904 2 4
6 13 622.84 18 14.71 1238 2 5
7 13 138.52 18 14.85 541 2 3
8 13 60.16 18 14.88 410 2 3
9 8 0.16 175 14.86 302 2 8

Cycle 217 GMT 13/ 7/2024 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 33 14.84 447 2 2
2 12 1178.08 2 15.01 2031 2 2
3 7 1712.16 32 14.70 2592 2 3
4 13 1441.52 18 14.68 2282 2 3
5 13 958.12 18 14.70 1673 2 4
6 13 446.88 18 14.78 991 2 5
7 13 141.76 18 14.87 535 2 3
8 13 50.56 18 14.89 389 2 3
9 8 -0.04 175 14.87 300 2 9

Cycle 216 GMT 3/ 7/2024 14: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 33 14.84 435 2 2
2 12 1198.48 2 15.00 2067 2 2
3 7 1819.24 32 14.66 2730 2 3
4 13 1511.88 18 14.66 2372 2 3
5 13 1036.12 18 14.67 1771 2 4
6 13 509.44 18 14.75 1081 2 5
7 13 163.88 18 14.85 579 2 3
8 13 55.24 18 14.88 397 2 3
9 8 0.24 175 14.86 305 2 10

Cycle 215 GMT 23/ 6/2024 13:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 33 14.87 444 2 2
2 12 1178.92 2 15.00 2055 2 2
3 7 1971.76 31 14.62 2909 2 3
4 13 1646.04 18 14.60 2534 2 3
5 13 1146.20 18 14.62 1912 2 3
6 13 628.76 18 14.69 1240 2 4
7 13 151.40 18 14.84 556 2 3
8 13 49.04 18 14.87 388 2 3
9 8 0.08 175 14.85 301 2 9

Cycle 214 GMT 13/ 6/2024 13: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 33 14.84 438 2 2
2 12 1157.28 2 15.01 2004 2 2
3 7 1186.00 31 14.89 1941 2 3
4 13 1134.52 18 14.84 1882 2 3
5 13 987.32 18 14.81 1695 2 3
6 13 330.44 18 14.89 823 2 4
7 13 100.40 18 14.94 468 2 3
8 13 54.36 18 14.94 397 2 3
9 8 0.04 175 14.91 300 2 8

Cycle 213 GMT 3/ 6/2024 13:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 33 14.85 437 2 2
2 12 1187.64 2 15.01 2041 2 2
3 7 1473.16 31 14.78 2305 2 3
4 13 1365.76 18 14.75 2185 2 3
5 13 884.36 18 14.77 1575 2 4
6 13 391.00 18 14.83 913 2 4
7 13 114.08 18 14.89 498 2 3
8 13 35.68 18 14.91 373 2 3
9 8 0.12 175 14.88 305 2 8

Cycle 212 GMT 24/ 5/2024 13:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 33 14.84 432 2 2
2 12 1169.20 2 15.01 2017 2 2
3 7 1731.80 31 14.69 2621 2 3
4 13 1581.44 18 14.67 2442 2 3
5 13 1080.60 18 14.69 1831 2 3
6 13 425.00 18 14.79 959 2 4
7 13 135.44 18 14.87 526 2 3
8 13 43.64 18 14.89 383 2 3
9 8 0.12 175 14.87 299 2 8

Cycle 211 GMT 14/ 5/2024 13:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 33 14.84 437 2 2
2 12 1161.92 2 15.01 2024 2 2
3 7 1869.60 32 14.65 2783 2 3
4 13 1555.12 18 14.64 2427 2 3
5 13 1071.04 18 14.66 1818 2 3
6 13 569.92 18 14.73 1161 2 4
7 13 120.48 18 14.86 509 2 3
8 13 44.24 18 14.88 385 2 3
9 8 0.12 175 14.85 301 2 7

Cycle 210 GMT 4/ 5/2024 12:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 33 14.83 433 2 2
2 12 1163.56 2 15.01 2019 2 2
3 7 1758.44 31 14.68 2646 2 3
4 13 1607.44 18 14.66 2473 2 3
5 13 1100.40 18 14.68 1846 2 4
6 13 424.04 18 14.79 968 2 5
7 13 132.16 18 14.87 523 2 3
8 13 42.04 18 14.89 379 2 3
9 8 0.12 175 14.86 300 2 12

Cycle 209 GMT 24/ 4/2024 12:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 33 14.85 440 2 2
2 12 1164.92 2 15.01 2023 2 2
3 7 1842.56 31 14.66 2748 2 3
4 13 1551.60 18 14.65 2412 2 3
5 13 1061.16 18 14.66 1811 2 4
6 13 587.08 18 14.73 1184 2 4
7 13 135.20 18 14.86 522 2 3
8 13 44.20 18 14.88 376 2 3
9 8 0.08 175 14.86 295 2 9

Cycle 208 GMT 14/ 4/2024 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 33 14.83 431 2 2
2 12 1158.08 2 15.03 1998 2 2
3 7 1618.80 31 14.74 2479 2 3
4 13 1481.84 18 14.71 2325 2 3
5 13 964.56 18 14.74 1683 2 4
6 13 622.56 18 14.77 1231 2 4
7 13 124.80 18 14.88 520 2 3
8 13 44.36 18 14.90 390 2 3
9 8 0.12 175 14.88 307 2 9

Cycle 207 GMT 4/ 4/2024 11:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 33 14.84 444 2 2
2 12 1160.76 2 15.02 2027 2 2
3 7 1988.88 32 14.61 2923 2 3
4 13 1656.24 18 14.61 2553 2 3
5 13 1137.52 18 14.63 1894 2 4
6 13 595.08 18 14.72 1194 2 4
7 13 132.68 18 14.86 523 2 3
8 13 71.08 18 14.87 429 2 3
9 13 17.84 18 14.88 337 2 3
10 8 0.00 175 14.84 304 2 11

Cycle 206 GMT 25/ 3/2024 11: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 33 14.83 438 2 2
2 12 1157.72 2 15.02 2023 2 2
3 7 2008.24 31 14.63 2933 2 2
4 13 1685.96 18 14.61 2569 2 2
5 13 1164.84 18 14.63 1934 2 3
6 13 616.52 18 14.72 1225 2 4
7 13 142.92 18 14.86 537 2 3
8 13 52.36 18 14.88 392 2 3
9 8 0.12 175 14.86 300 2 8

Cycle 205 GMT 15/ 3/2024 13: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 33 14.83 449 2 2
2 12 1191.52 2 15.01 2052 2 2
3 7 2002.60 31 14.62 2942 2 2
4 13 1672.36 18 14.61 2567 2 3
5 13 1346.48 18 14.60 2167 2 3
6 13 619.32 18 14.71 1229 2 4
7 13 150.52 18 14.85 548 2 3
8 13 45.60 18 14.88 384 2 3
9 8 0.08 175 14.86 301 2 10

Cycle 204 GMT 5/ 3/2024 15: 5: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 33 14.86 439 2 2
2 12 1168.68 2 15.02 2005 2 2
3 7 2005.92 31 14.62 2931 2 3
4 13 1667.40 18 14.61 2554 2 3
5 13 1031.48 18 14.65 1761 2 4
6 13 551.48 18 14.73 1134 2 4
7 13 197.72 18 14.83 625 2 3
8 13 48.16 18 14.87 392 2 3
9 8 0.12 175 14.85 305 2 8

Cycle 203 GMT 24/ 2/2024 16:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 33 14.83 432 2 2
2 12 1168.16 2 15.02 2016 2 2
3 7 1382.24 31 14.83 2187 2 3
4 13 1281.36 18 14.80 2078 2 3
5 13 1129.36 18 14.77 1884 2 4
6 13 456.72 18 14.85 994 2 4
7 13 141.88 18 14.91 538 2 3
8 13 40.60 18 14.93 380 2 3
9 8 0.00 175 14.90 304 2 8

Cycle 202 GMT 14/ 2/2024 17:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 33 14.83 442 2 2
2 12 1178.76 2 15.02 2034 2 2
3 7 1895.56 31 14.64 2818 2 3
4 13 1610.72 18 14.63 2495 2 3
5 13 1126.00 18 14.65 1877 2 4
6 13 600.32 18 14.73 1195 2 4
7 13 151.80 18 14.85 555 2 3
8 13 78.92 18 14.86 436 2 3
9 8 0.04 175 14.85 302 2 10

Cycle 201 GMT 4/ 2/2024 16:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 33 14.84 431 2 2
2 12 1171.96 2 15.02 2024 2 2
3 7 1778.52 31 14.69 2677 2 3
4 13 1628.96 18 14.66 2506 2 3
5 13 967.60 18 14.71 1680 2 4
6 13 488.32 18 14.78 1044 2 4
7 13 166.96 18 14.86 577 2 3
8 13 49.96 18 14.89 392 2 3
9 8 0.08 175 14.86 300 2 8

Cycle 200 GMT 25/ 1/2024 16: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 33 14.83 436 2 2
2 12 1167.84 2 15.03 2011 2 2
3 7 2010.84 32 14.63 2938 2 3
4 13 1685.12 18 14.61 2574 2 3
5 13 1011.44 18 14.66 1734 2 3
6 13 526.56 18 14.74 1093 2 5
7 13 179.12 18 14.84 593 2 3
8 13 56.48 18 14.88 397 2 3
9 8 0.16 175 14.86 300 2 9

Cycle 199 GMT 15/ 1/2024 18: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 33 14.83 443 2 2
2 12 1182.96 2 15.02 2051 2 2
3 7 2014.52 31 14.63 2945 2 3
4 13 1864.88 18 14.59 2799 2 3
5 13 1135.16 18 14.64 1893 2 3
6 13 622.64 18 14.72 1227 2 4
7 13 147.68 18 14.85 545 2 3
8 13 82.60 18 14.87 442 2 3
9 8 0.12 175 14.85 303 2 8

Cycle 198 GMT 5/ 1/2024 20:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 33 14.84 439 2 2
2 12 1185.92 2 15.02 2036 2 2
3 7 2002.56 31 14.63 2934 2 2
4 13 1681.92 18 14.62 2560 2 3
5 13 1018.92 18 14.67 1746 2 3
6 13 543.52 18 14.74 1126 2 4
7 13 133.40 18 14.86 514 2 3
8 13 70.16 18 14.87 419 2 3
9 8 0.04 175 14.86 299 2 8

Cycle 197 GMT 26/12/2023 22:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 33 14.82 448 2 2
2 12 1181.00 2 15.02 2028 2 2
3 7 2009.52 31 14.63 2947 2 3
4 13 1538.00 18 14.63 2399 2 3
5 13 1050.20 18 14.66 1788 2 3
6 13 546.28 18 14.73 1126 2 3
7 13 130.84 18 14.86 511 2 3
8 13 75.04 18 14.87 424 2 3
9 8 0.16 175 14.86 301 2 8

Cycle 196 GMT 17/12/2023 0:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 33 14.84 444 2 2
2 12 1151.72 2 15.02 2010 2 2
3 7 2002.64 31 14.63 2947 2 2
4 13 1672.84 18 14.62 2558 2 3
5 13 1143.96 18 14.64 1905 2 3
6 13 616.28 18 14.72 1225 2 4
7 13 140.84 18 14.86 532 2 3
8 13 73.60 18 14.87 428 2 3
9 8 0.12 175 14.85 303 2 7

Cycle 195 GMT 7/12/2023 2:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 33 14.83 434 2 2
2 12 1146.08 2 15.02 2002 2 2
3 7 2002.68 31 14.63 2943 2 3
4 13 1660.36 18 14.62 2551 2 3
5 13 1136.40 18 14.65 1892 2 3
6 13 461.64 18 14.77 1012 2 4
7 13 155.60 18 14.85 555 2 3
8 13 51.44 18 14.88 390 2 3
9 8 0.12 175 14.86 299 2 6

Cycle 194 GMT 27/11/2023 4:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 33 14.82 436 2 2
2 12 1152.84 2 15.03 2006 2 2
3 7 2009.00 31 14.63 2950 2 3
4 13 1531.84 18 14.63 2394 2 3
5 13 1048.16 18 14.65 1784 2 3
6 13 541.44 18 14.74 1115 2 4
7 13 196.40 18 14.83 619 2 3
8 13 61.76 18 14.88 402 2 3
9 8 0.08 175 14.86 299 2 8

Cycle 193 GMT 17/11/2023 6:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 33 14.85 434 2 2
2 12 1167.20 2 15.03 2038 2 2
3 7 2004.04 32 14.63 2943 2 3
4 13 1685.72 18 14.61 2580 2 3
5 13 1155.44 18 14.64 1923 2 3
6 13 627.16 18 14.71 1235 2 4
7 13 147.60 18 14.85 542 2 3
8 13 78.68 18 14.86 435 2 3
9 8 0.08 175 14.84 302 2 9

Cycle 192 GMT 7/11/2023 8: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 33 14.83 443 2 2
2 12 1176.84 2 15.03 2029 2 2
3 7 2003.36 32 14.63 2937 2 2
4 13 1695.28 18 14.62 2592 2 3
5 13 1146.88 18 14.64 1905 2 3
6 13 613.48 18 14.72 1215 2 4
7 13 160.96 18 14.85 556 2 3
8 13 83.60 18 14.86 436 2 3
9 8 0.08 175 14.85 300 2 9
10 14 0.08 15 14.83 300 2 10

Cycle 191 GMT 28/10/2023 10:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 33 14.82 444 2 2
2 12 1164.44 2 15.04 2016 2 2
3 7 2004.00 31 14.64 2943 2 3
4 13 1523.56 18 14.65 2372 2 3
5 13 1044.72 18 14.66 1784 2 3
6 13 543.40 18 14.74 1120 2 4
7 13 136.80 18 14.86 515 2 3
8 13 85.84 18 14.87 435 2 3
9 8 0.16 175 14.86 295 2 8

Cycle 190 GMT 18/10/2023 11:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 33 14.82 437 2 2
2 12 1181.96 2 15.03 2035 2 2
3 7 2008.40 31 14.63 2948 2 3
4 13 1523.40 18 14.65 2381 2 3
5 13 1027.08 18 14.67 1764 2 3
6 13 523.12 18 14.75 1098 2 4
7 13 176.76 18 14.84 592 2 3
8 13 53.72 18 14.88 394 2 3
9 8 0.08 175 14.86 301 2 8

Cycle 189 GMT 8/10/2023 13:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 33 14.85 434 2 2
2 12 1172.24 2 15.03 2030 2 2
3 7 2003.60 31 14.64 2935 2 2
4 13 1690.40 18 14.63 2582 2 3
5 13 1183.12 18 14.64 1952 2 3
6 13 663.48 18 14.71 1283 2 4
7 13 164.12 18 14.85 569 2 3
8 13 52.40 18 14.88 395 2 3
9 8 0.04 175 14.85 305 2 8

Cycle 188 GMT 28/ 9/2023 15:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 33 14.82 450 2 2
2 12 1168.56 2 15.03 2016 2 2
3 7 2005.72 31 14.64 2934 2 3
4 13 1535.12 18 14.64 2393 2 3
5 13 1039.72 18 14.66 1773 2 3
6 13 540.88 18 14.74 1115 2 4
7 13 132.60 18 14.86 514 2 3
8 13 72.56 18 14.87 425 2 3
9 8 0.04 175 14.86 298 2 8

Cycle 187 GMT 18/ 9/2023 17:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 33 14.84 446 2 2
2 12 1176.48 2 15.03 2032 2 2
3 7 2004.80 31 14.65 2939 2 3
4 13 1552.80 18 14.64 2412 2 3
5 13 1233.40 18 14.63 2018 2 3
6 13 526.80 18 14.74 1102 2 5
7 13 184.60 18 14.84 602 2 3
8 13 63.12 18 14.87 414 2 3
9 8 0.08 175 14.85 301 2 11

Cycle 186 GMT 8/ 9/2023 19:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 33 14.83 437 2 2
2 12 1166.00 2 15.04 2035 2 2
3 7 2002.36 31 14.64 2935 2 3
4 13 1525.36 18 14.65 2391 2 3
5 13 1203.28 18 14.64 1985 2 3
6 13 504.68 18 14.75 1069 2 4
7 13 168.64 18 14.85 580 2 3
8 13 63.32 18 14.88 410 2 3
9 8 0.12 175 14.86 301 2 7

Cycle 185 GMT 29/ 8/2023 21:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 33 14.83 453 2 2
2 12 1161.12 2 15.04 2021 2 2
3 7 2005.56 31 14.65 2946 2 2
4 13 1696.44 18 14.63 2597 2 3
5 13 1164.92 18 14.65 1946 2 3
6 13 647.40 18 14.71 1266 2 4
7 13 157.64 18 14.85 562 2 3
8 13 82.72 18 14.87 443 2 3
9 8 0.04 175 14.85 306 2 10

Cycle 184 GMT 19/ 8/2023 23:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 33 14.84 416 2 2
2 12 1182.68 2 15.04 2058 2 2
3 7 2009.56 31 14.66 2946 2 3
4 13 1690.92 18 14.63 2588 2 3
5 13 1161.32 18 14.65 1931 2 3
6 13 494.40 18 14.76 1053 2 4
7 13 175.72 18 14.84 584 2 3
8 13 93.00 18 14.87 456 2 3
9 8 -0.04 175 14.85 303 2 10

Cycle 183 GMT 10/ 8/2023 1:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 33 14.83 439 2 2
2 12 1176.88 2 15.03 2037 2 2
3 7 2004.48 31 14.64 2940 2 3
4 13 1690.12 18 14.63 2587 2 3
5 13 1169.40 18 14.65 1955 2 4
6 13 509.76 18 14.76 1077 2 4
7 13 182.20 18 14.85 598 2 3
8 13 63.12 18 14.88 410 2 3
9 8 1.00 175 14.86 298 2 7

Cycle 182 GMT 31/ 7/2023 3:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 33 14.82 447 2 2
2 12 1183.28 2 15.04 2026 2 2
3 7 2004.36 32 14.63 2935 2 3
4 13 1533.40 18 14.64 2405 2 3
5 13 1035.84 18 14.67 1772 2 4
6 13 532.64 18 14.75 1110 2 4
7 13 186.44 18 14.84 606 2 3
8 13 60.44 18 14.87 408 2 3
9 8 0.04 175 14.86 302 2 8

Cycle 181 GMT 21/ 7/2023 5:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 33 14.85 436 2 2
2 12 1164.16 2 15.04 2028 2 2
3 7 2011.08 32 14.64 2945 2 3
4 13 1538.04 18 14.64 2401 2 3
5 13 1044.60 18 14.67 1790 2 4
6 13 533.52 18 14.74 1112 2 4
7 13 185.80 18 14.84 604 2 3
8 13 63.92 18 14.87 410 2 3
9 8 0.00 175 14.85 301 2 6

Cycle 180 GMT 11/ 7/2023 7:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 33 14.83 442 2 2
2 12 1161.88 2 15.05 2017 2 2
3 7 2011.88 31 14.64 2940 2 3
4 13 1699.16 18 14.62 2587 2 3
5 13 1036.80 18 14.67 1775 2 3
6 13 539.28 18 14.74 1122 2 4
7 13 131.12 18 14.86 527 2 3
8 13 79.88 18 14.87 431 2 3
9 8 0.12 175 14.86 299 2 9

Cycle 179 GMT 1/ 7/2023 9:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 33 14.83 448 2 2
2 12 1187.24 2 15.03 2061 2 2
3 7 2005.44 31 14.65 2934 2 2
4 13 1690.96 18 14.63 2590 2 3
5 13 1027.40 18 14.67 1756 2 3
6 13 544.76 18 14.74 1126 2 4
7 13 205.64 18 14.84 632 2 3
8 13 78.20 18 14.87 429 2 3
9 8 0.12 175 14.86 298 2 8

Cycle 178 GMT 21/ 6/2023 11: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 33 14.85 441 2 2
2 12 1174.72 2 15.04 2023 2 2
3 7 2005.84 31 14.65 2942 2 3
4 13 1667.76 18 14.64 2559 2 3
5 13 1146.32 18 14.66 1924 2 3
6 13 632.64 18 14.73 1240 2 4
7 13 164.32 18 14.86 563 2 3
8 13 92.32 18 14.87 451 2 3
9 13 24.36 18 14.89 340 2 3
10 8 0.04 175 14.86 296 2 7

Cycle 177 GMT 11/ 6/2023 12:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 33 14.83 447 2 2
2 12 1180.00 2 15.04 2039 2 2
3 7 2005.40 31 14.65 2943 2 3
4 13 1697.44 18 14.62 2598 2 3
5 13 1038.72 18 14.67 1776 2 4
6 13 553.28 18 14.74 1136 2 4
7 13 141.40 18 14.86 525 2 3
8 13 77.92 18 14.87 427 2 3
9 8 0.20 175 14.87 295 2 8

Cycle 176 GMT 1/ 6/2023 14:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 33 14.83 444 2 2
2 12 1171.88 2 15.05 2045 2 2
3 7 2003.84 31 14.65 2941 2 2
4 13 1522.32 18 14.64 2387 2 3
5 13 1027.88 18 14.68 1762 2 3
6 13 522.96 18 14.75 1105 2 4
7 13 183.96 18 14.85 604 2 3
8 13 73.76 18 14.88 424 2 3
9 13 40.08 18 14.88 368 2 3
10 8 0.08 175 14.85 296 2 9

Cycle 175 GMT 22/ 5/2023 16:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 33 14.85 433 2 2
2 12 1177.56 2 15.04 2027 2 2
3 7 2011.24 32 14.64 2946 2 3
4 13 1687.88 18 14.63 2583 2 3
5 13 1160.60 18 14.65 1934 2 3
6 13 491.40 18 14.76 1054 2 5
7 13 172.28 18 14.85 582 2 3
8 13 59.16 18 14.88 400 2 3
9 13 32.96 18 14.88 358 2 3
10 8 -0.08 175 14.85 296 2 10

Cycle 174 GMT 12/ 5/2023 18:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 33 14.84 437 2 2
2 12 1162.96 2 15.05 2025 2 2
3 7 2007.08 31 14.65 2943 2 3
4 13 1693.72 18 14.63 2591 2 3
5 13 1019.76 18 14.68 1749 2 3
6 13 685.20 18 14.71 1315 2 3
7 13 176.28 18 14.85 583 2 3
8 13 98.36 18 14.86 462 2 3
9 8 0.08 175 14.86 293 2 9

Cycle 173 GMT 2/ 5/2023 19:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 33 14.83 441 2 2
2 12 1161.16 2 15.05 2010 2 2
3 7 2009.32 31 14.65 2945 2 3
4 13 1683.04 18 14.64 2567 2 3
5 13 1156.72 18 14.66 1925 2 3
6 13 635.32 18 14.73 1253 2 4
7 13 163.92 18 14.86 567 2 3
8 13 66.92 18 14.89 418 2 3
9 13 36.48 18 14.89 360 2 3
10 8 0.00 175 14.86 295 2 8

Cycle 172 GMT 22/ 4/2023 21:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 33 14.83 442 2 2
2 12 1175.20 2 15.05 2051 2 2
3 7 2005.52 31 14.64 2934 2 2
4 13 1523.00 18 14.65 2381 2 3
5 13 1020.72 18 14.68 1748 2 3
6 13 524.12 18 14.76 1094 2 4
7 13 192.12 18 14.85 607 2 3
8 13 63.04 18 14.88 401 2 3
9 8 0.16 175 14.86 294 2 7

Cycle 171 GMT 12/ 4/2023 23:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 33 14.84 437 2 2
2 12 1185.52 2 15.03 2044 2 2
3 7 2006.84 32 14.65 2932 2 3
4 13 1536.76 18 14.65 2392 2 3
5 13 1035.76 18 14.68 1766 2 3
6 13 526.12 18 14.76 1094 2 4
7 13 189.60 18 14.84 605 2 3
8 13 63.20 18 14.88 405 2 3
9 8 0.16 175 14.86 297 2 9

Cycle 170 GMT 3/ 4/2023 1:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 33 14.84 442 2 2
2 12 1178.32 2 15.05 2029 2 2
3 7 2008.08 31 14.65 2939 2 3
4 13 1546.04 18 14.65 2402 2 3
5 13 1064.52 18 14.67 1817 2 3
6 13 555.84 18 14.74 1137 2 4
7 13 146.76 18 14.87 530 2 3
8 13 81.12 18 14.88 429 2 3
9 13 20.44 18 14.89 333 2 2
10 8 0.00 175 14.85 293 2 8

Cycle 169 GMT 24/ 3/2023 3:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 33 14.82 444 2 2
2 12 1183.32 2 15.03 2041 2 2
3 7 2003.40 31 14.64 2938 2 3
4 13 1519.08 18 14.66 2365 2 3
5 13 1030.76 18 14.68 1769 2 4
6 13 536.04 18 14.75 1114 2 4
7 13 191.04 18 14.85 610 2 3
8 13 68.20 18 14.88 413 2 3
9 8 0.12 175 14.87 296 2 8

Cycle 168 GMT 14/ 3/2023 5:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 33 14.84 443 2 2
2 12 1163.00 2 15.04 2000 2 2
3 7 2006.76 31 14.65 2933 2 3
4 13 1682.08 18 14.64 2579 2 3
5 13 1014.56 18 14.68 1739 2 3
6 13 541.64 18 14.75 1119 2 4
7 13 198.00 18 14.84 622 2 3
8 13 58.32 18 14.87 405 2 3
9 8 0.12 175 14.86 299 2 8

Cycle 167 GMT 4/ 3/2023 7:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 33 14.84 433 2 2
2 12 1174.56 2 15.03 2027 2 2
3 7 2009.24 31 14.65 2930 2 2
4 13 1678.44 18 14.64 2562 2 3
5 13 999.52 18 14.69 1716 2 4
6 13 516.04 18 14.76 1083 2 4
7 13 183.24 18 14.85 591 2 3
8 13 65.44 18 14.88 407 2 3
9 13 16.84 18 14.89 327 2 2
10 8 0.04 175 14.86 293 2 8
11 14 0.04 15 14.84 291 4 9

Cycle 166 GMT 22/ 2/2023 9: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 33 14.85 436 2 2
2 12 1175.96 2 15.05 2016 2 2
3 7 2010.08 31 14.65 2937 2 3
4 13 1685.72 18 14.64 2579 2 2
5 13 1017.04 18 14.68 1744 2 3
6 13 531.60 18 14.75 1102 2 4
7 13 195.08 18 14.85 604 2 3
8 13 62.36 18 14.88 402 2 3
9 8 0.08 175 14.87 294 2 8

Cycle 165 GMT 12/ 2/2023 10:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 33 14.85 426 2 2
2 12 1169.48 2 15.05 2017 2 2
3 7 2010.32 31 14.66 2947 2 2
4 13 1686.20 18 14.65 2578 2 3
5 13 1021.20 18 14.68 1750 2 3
6 13 533.44 18 14.76 1100 2 4
7 13 193.76 18 14.85 612 2 3
8 13 65.32 18 14.88 407 2 3
9 8 0.16 175 14.87 295 2 9

Cycle 164 GMT 2/ 2/2023 12:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 33 14.84 451 2 2
2 12 1170.28 2 15.04 2029 2 2
3 7 2008.56 31 14.65 2937 2 3
4 13 1677.92 18 14.65 2561 2 3
5 13 1009.48 18 14.69 1736 2 3
6 13 520.72 18 14.76 1094 2 4
7 13 192.32 18 14.85 603 2 3
8 13 65.76 18 14.89 401 2 3
9 8 0.12 175 14.88 290 2 10

Cycle 163 GMT 23/ 1/2023 14:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 33 14.85 438 2 2
2 12 1166.04 2 15.06 2039 2 2
3 7 2008.24 31 14.66 2942 2 2
4 13 1544.92 18 14.66 2398 2 3
5 13 1218.76 18 14.65 2003 2 3
6 13 677.72 18 14.72 1307 2 4
7 13 175.24 18 14.86 574 2 3
8 13 96.76 18 14.87 451 2 3
9 8 0.12 175 14.87 295 2 9

Cycle 162 GMT 13/ 1/2023 16:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 33 14.84 445 2 2
2 12 1173.48 2 15.05 2039 2 2
3 7 2009.28 32 14.65 2942 2 2
4 13 1683.72 18 14.64 2577 2 3
5 13 1003.28 18 14.69 1729 2 3
6 13 523.48 18 14.77 1098 2 4
7 13 184.64 18 14.86 599 2 3
8 13 100.00 18 14.88 467 2 3
9 8 0.16 175 14.87 299 2 8

Cycle 161 GMT 3/ 1/2023 18:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 33 14.84 440 2 2
2 12 1157.08 2 15.06 1992 2 2
3 7 2003.96 31 14.67 2938 2 3
4 13 1528.44 18 14.67 2383 2 3
5 13 1040.64 18 14.69 1783 2 3
6 13 534.16 18 14.76 1115 2 4
7 13 192.80 18 14.85 614 2 3
8 13 58.92 18 14.89 403 2 3
9 8 0.20 175 14.87 302 2 10

Cycle 160 GMT 24/12/2022 20:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 33 14.83 443 2 2
2 12 1166.20 2 15.06 2021 2 2
3 7 2004.24 31 14.65 2931 2 3
4 13 1525.76 18 14.66 2391 2 3
5 13 1061.16 18 14.68 1799 2 3
6 13 549.44 18 14.76 1138 2 4
7 13 135.84 18 14.88 519 2 3
8 13 73.00 18 14.89 422 2 3
9 13 16.20 18 14.90 333 2 3
10 8 0.08 175 14.86 300 2 9

Cycle 159 GMT 14/12/2022 21:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 33 14.83 448 2 2
2 12 1175.56 2 15.04 2036 2 2
3 7 2004.24 31 14.67 2939 2 3
4 13 1402.48 18 14.69 2231 2 3
5 13 1250.68 18 14.66 2036 2 3
6 13 540.16 18 14.76 1119 2 4
7 13 207.40 18 14.85 638 2 3
8 13 62.60 18 14.89 414 2 3
9 13 16.08 18 14.89 338 2 3
10 8 -0.04 175 14.86 306 2 6

Cycle 158 GMT 4/12/2022 23:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 33 14.85 446 2 2
2 12 1168.32 2 15.06 2018 2 2
3 7 2002.16 31 14.66 2927 2 3
4 13 1676.88 18 14.65 2568 2 3
5 13 986.68 18 14.70 1705 2 3
6 13 486.40 18 14.78 1045 2 3
7 13 165.36 18 14.87 570 2 3
8 13 87.52 18 14.88 447 2 3
9 8 0.16 175 14.87 301 2 7

Cycle 157 GMT 25/11/2022 1:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 33 14.85 436 2 2
2 12 1178.04 2 15.06 2045 2 2
3 7 2011.60 31 14.67 2939 2 3
4 13 1691.28 18 14.65 2584 2 3
5 13 1169.48 18 14.67 1941 2 3
6 13 652.84 18 14.74 1269 2 4
7 13 161.12 18 14.87 565 2 3
8 13 85.60 18 14.88 446 2 3
9 8 0.20 175 14.87 299 2 8

Cycle 156 GMT 15/11/2022 3:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 33 14.84 454 2 2
2 12 1171.72 2 15.06 2048 2 2
3 7 2004.68 31 14.66 2939 2 2
4 13 1673.48 18 14.65 2552 2 3
5 13 1139.00 18 14.68 1903 2 3
6 13 491.84 18 14.78 1054 2 4
7 13 166.28 18 14.87 571 2 3
8 13 50.36 18 14.90 392 2 3
9 8 0.08 175 14.88 302 2 7

Cycle 155 GMT 5/11/2022 5:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 33 14.85 436 2 2
2 12 1155.16 2 15.05 2007 2 2
3 7 2005.20 31 14.67 2936 2 3
4 13 1535.52 18 14.67 2385 2 3
5 13 1050.76 18 14.70 1787 2 3
6 13 557.80 18 14.76 1139 2 4
7 13 205.68 18 14.85 641 2 3
8 13 62.40 18 14.89 408 2 3
9 8 0.20 175 14.87 301 2 8

Cycle 154 GMT 26/10/2022 7:39:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 33 14.85 441 2 2
2 12 1162.52 2 15.06 2029 2 2
3 7 2003.48 31 14.67 2944 2 3
4 13 1680.08 18 14.66 2576 2 2
5 13 1168.88 18 14.68 1935 2 3
6 13 629.24 18 14.75 1240 2 4
7 13 157.96 18 14.87 558 2 3
8 13 87.52 18 14.89 448 2 3
9 8 -0.08 175 14.88 297 2 7

Cycle 153 GMT 16/10/2022 9:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 33 14.86 433 2 2
2 12 1167.96 2 15.06 2026 2 2
3 7 2010.56 31 14.66 2948 2 3
4 13 1511.32 18 14.68 2366 2 3
5 13 1019.08 18 14.70 1759 2 3
6 13 519.04 18 14.77 1094 2 4
7 13 176.32 18 14.86 587 2 3
8 13 54.92 18 14.89 398 2 3
9 8 0.16 175 14.87 301 2 10

Cycle 152 GMT 6/10/2022 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 33 14.84 455 2 2
2 12 1160.40 2 15.07 2018 2 2
3 7 2001.88 31 14.67 2933 2 3
4 13 1684.80 18 14.65 2577 2 3
5 13 1150.12 18 14.68 1911 2 3
6 13 618.40 18 14.76 1225 2 3
7 13 156.92 18 14.88 547 2 3
8 13 91.40 18 14.89 444 2 3
9 8 0.12 175 14.88 297 2 6

Cycle 151 GMT 26/ 9/2022 13:33: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 33 14.84 444 2 2
2 12 1169.48 2 15.07 2023 2 2
3 7 2003.32 31 14.67 2924 2 3
4 13 1527.04 18 14.67 2393 2 3
5 13 1051.56 18 14.70 1784 2 3
6 13 701.76 18 14.73 1337 2 4
7 13 174.64 18 14.87 585 2 3
8 13 97.40 18 14.88 458 2 3
9 8 0.00 175 14.87 304 2 8

Cycle 150 GMT 16/ 9/2022 15:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 33 14.86 439 2 2
2 12 1165.84 2 15.06 2019 2 2
3 7 2011.12 31 14.67 2935 2 3
4 13 1698.44 18 14.65 2601 2 3
5 13 1179.88 18 14.68 1962 2 3
6 13 521.48 18 14.78 1092 2 4
7 13 195.60 18 14.87 612 2 3
8 13 102.92 18 14.89 467 2 3
9 8 0.04 175 14.88 301 2 10

Cycle 149 GMT 6/ 9/2022 17: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 33 14.86 442 2 2
2 12 1170.52 2 15.05 2026 2 2
3 7 2007.24 31 14.66 2936 2 3
4 13 1681.40 18 14.65 2579 2 3
5 13 1139.28 18 14.69 1897 2 3
6 13 462.08 18 14.80 1013 2 4
7 13 164.80 18 14.88 570 2 3
8 13 88.80 18 14.89 447 2 3
9 8 0.16 175 14.88 300 2 7

Cycle 148 GMT 27/ 8/2022 19: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 33 14.85 449 2 2
2 12 1173.92 2 15.06 2035 2 2
3 7 2007.56 31 14.66 2945 2 3
4 13 1679.04 18 14.65 2576 2 3
5 13 1002.96 18 14.71 1726 2 3
6 13 509.80 18 14.78 1075 2 4
7 13 185.64 18 14.87 598 2 3
8 13 65.24 18 14.91 408 2 3
9 8 0.16 175 14.89 297 2 9

Cycle 147 GMT 17/ 8/2022 20:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 33 14.85 442 2 2
2 12 1159.56 2 15.06 2006 2 2
3 7 2003.60 31 14.68 2929 2 3
4 13 1681.04 18 14.65 2571 2 3
5 13 1152.84 18 14.68 1927 2 3
6 13 615.00 18 14.75 1221 2 4
7 13 149.88 18 14.88 547 2 3
8 13 80.32 18 14.90 433 2 3
9 8 0.08 175 14.88 302 2 7

Cycle 146 GMT 7/ 8/2022 22:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 33 14.87 435 2 2
2 12 1176.12 2 15.07 2026 2 2
3 7 2007.16 31 14.68 2940 2 2
4 13 1517.92 18 14.68 2374 2 3
5 13 1055.00 18 14.70 1800 2 3
6 13 544.84 18 14.77 1125 2 4
7 13 199.16 18 14.86 620 2 3
8 13 63.92 18 14.90 409 2 2
9 8 0.12 175 14.88 301 2 6

Cycle 145 GMT 29/ 7/2022 0:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 33 14.86 449 2 2
2 12 1182.72 2 15.05 2044 2 2
3 7 2004.00 31 14.68 2934 2 3
4 13 1849.16 18 14.64 2772 2 3
5 13 1126.32 18 14.69 1890 2 3
6 13 590.96 18 14.77 1187 2 4
7 13 150.52 18 14.89 545 2 3
8 13 89.36 18 14.90 447 2 3
9 8 0.04 175 14.89 297 2 7

Cycle 144 GMT 19/ 7/2022 2:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 33 14.86 441 2 2
2 12 1179.32 2 15.06 2025 2 2
3 7 2003.76 31 14.68 2935 2 3
4 13 1656.00 18 14.67 2545 2 3
5 13 1137.36 18 14.70 1895 2 3
6 13 624.28 18 14.77 1233 2 4
7 13 156.84 18 14.89 555 2 3
8 13 93.80 18 14.90 452 2 3
9 8 0.12 175 14.89 301 2 8

Cycle 143 GMT 9/ 7/2022 4:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 33 14.87 443 2 2
2 12 1182.92 2 15.05 2034 2 2
3 7 2010.24 31 14.67 2935 2 3
4 13 1531.48 18 14.68 2389 2 3
5 13 1049.32 18 14.69 1788 2 3
6 13 536.12 18 14.78 1116 2 3
7 13 124.80 18 14.90 502 2 3
8 13 72.48 18 14.90 423 2 3
9 8 0.08 175 14.89 300 2 9

Cycle 142 GMT 29/ 6/2022 6:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 33 14.87 447 2 2
2 12 1177.08 2 15.07 2029 2 2
3 7 2008.20 31 14.67 2938 2 2
4 13 1522.04 18 14.68 2370 2 3
5 13 1026.12 18 14.71 1763 2 4
6 13 514.52 18 14.79 1087 2 5
7 13 178.56 18 14.88 587 2 3
8 13 65.12 18 14.91 406 2 3
9 8 0.16 175 14.89 299 2 13

Cycle 141 GMT 19/ 6/2022 8:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 33 14.87 441 2 2
2 12 1164.60 2 15.07 2025 2 2
3 7 2002.80 31 14.67 2930 2 3
4 13 1668.64 18 14.67 2550 2 3
5 13 1150.08 18 14.69 1924 2 3
6 13 489.56 18 14.80 1045 2 4
7 13 172.88 18 14.89 576 2 3
8 13 91.92 18 14.90 452 2 3
9 8 0.04 175 14.90 297 2 8

Cycle 140 GMT 9/ 6/2022 10:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 33 14.86 444 2 2
2 12 1170.20 2 15.06 2018 2 2
3 7 2010.20 31 14.67 2946 2 3
4 13 1531.16 18 14.68 2394 2 3
5 13 1185.80 18 14.68 1957 2 3
6 13 483.80 18 14.80 1040 2 4
7 13 166.92 18 14.89 570 2 3
8 13 89.96 18 14.90 446 2 3
9 8 0.12 175 14.90 301 2 11

Cycle 139 GMT 30/ 5/2022 12: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 33 14.87 446 2 2
2 12 1190.16 2 15.05 2064 2 2
3 7 2004.20 31 14.67 2933 2 3
4 13 1512.28 18 14.69 2359 2 3
5 13 1026.44 18 14.71 1760 2 3
6 13 517.92 18 14.79 1087 2 4
7 13 182.72 18 14.88 595 2 3
8 13 58.36 18 14.92 399 2 3
9 13 15.48 18 14.92 330 2 3
10 8 0.08 175 14.89 299 2 10

Cycle 138 GMT 20/ 5/2022 13:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 33 14.87 443 2 2
2 12 1170.04 2 15.07 2022 2 2
3 7 2003.64 31 14.68 2934 2 3
4 13 1519.24 18 14.68 2380 2 3
5 13 1042.48 18 14.71 1787 2 3
6 13 530.16 18 14.79 1106 2 4
7 13 188.36 18 14.87 612 2 3
8 13 54.12 18 14.91 400 2 3
9 8 0.12 175 14.89 303 2 9

Cycle 137 GMT 10/ 5/2022 15:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 33 14.87 446 2 2
2 12 1174.04 2 15.07 2037 2 2
3 7 2012.68 32 14.67 2951 2 2
4 13 1688.44 18 14.66 2581 2 3
5 13 1007.64 18 14.71 1740 2 3
6 13 502.04 18 14.79 1066 2 5
7 13 164.72 18 14.88 572 2 3
8 13 56.88 18 14.92 401 2 3
9 13 17.40 18 14.92 338 2 3
10 8 -0.04 175 14.89 302 2 11

Cycle 136 GMT 30/ 4/2022 17:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 33 14.87 433 2 2
2 12 1183.16 2 15.06 2030 2 2
3 7 2004.84 31 14.68 2930 2 2
4 13 1671.32 18 14.67 2563 2 3
5 13 1000.04 18 14.72 1732 2 4
6 13 518.00 18 14.79 1095 2 4
7 13 193.24 18 14.88 612 2 3
8 13 62.96 18 14.92 407 2 3
9 13 17.24 18 14.93 333 2 3
10 8 0.00 175 14.89 298 2 8

Cycle 135 GMT 20/ 4/2022 19:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 33 14.87 441 2 2
2 12 1174.16 2 15.07 2031 2 2
3 7 2008.08 31 14.68 2941 2 3
4 13 1519.56 18 14.69 2377 2 3
5 13 1179.96 18 14.69 1959 2 3
6 13 636.80 18 14.77 1250 2 4
7 13 157.56 18 14.89 557 2 3
8 13 87.96 18 14.91 447 2 3
9 13 22.56 18 14.92 343 2 3
10 8 0.00 175 14.89 296 2 8

Cycle 134 GMT 10/ 4/2022 21:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 33 14.87 442 2 2
2 12 1167.00 2 15.07 2020 2 2
3 7 2006.00 31 14.67 2940 2 3
4 13 1522.44 18 14.68 2390 2 3
5 13 1017.60 18 14.72 1750 2 3
6 13 499.32 18 14.80 1070 2 4
7 13 163.40 18 14.89 570 2 3
8 13 87.32 18 14.90 451 2 3
9 8 0.08 175 14.90 301 2 8

Cycle 133 GMT 31/ 3/2022 23:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 33 14.88 437 2 2
2 12 1155.12 2 15.07 1992 2 2
3 7 1936.48 31 14.69 2855 2 3
4 13 1630.60 18 14.68 2519 2 3
5 13 1100.68 18 14.71 1854 2 3
6 13 425.00 18 14.83 963 2 5
7 13 148.88 18 14.90 537 2 3
8 13 82.52 18 14.92 433 2 3
9 13 19.88 18 14.93 334 2 3
10 8 0.16 175 14.89 297 2 10

Cycle 132 GMT 21/ 3/2022 22:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 33 14.87 446 2 2
2 12 1167.84 2 15.07 2012 2 2
3 7 2003.96 31 14.68 2930 2 2
4 13 1677.48 18 14.67 2567 2 3
5 13 1195.80 18 14.69 1969 2 3
6 13 512.20 18 14.80 1079 2 4
7 13 190.76 18 14.89 606 2 3
8 13 67.76 18 14.92 410 2 3
9 13 17.00 18 14.94 329 2 3
10 8 0.08 175 14.90 296 2 10

Cycle 131 GMT 12/ 3/2022 0:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 33 14.89 437 2 2
2 12 1174.04 2 15.08 2034 2 2
3 7 2005.56 31 14.68 2928 2 2
4 13 1540.80 18 14.69 2397 2 3
5 13 1048.68 18 14.71 1783 2 4
6 13 535.40 18 14.79 1115 2 4
7 13 195.52 18 14.88 613 2 3
8 13 68.52 18 14.92 411 2 3
9 13 21.04 18 14.93 334 2 3
10 8 0.12 175 14.89 295 2 10

Cycle 130 GMT 2/ 3/2022 2: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 33 14.88 448 2 2
2 12 1168.20 2 15.07 2030 2 2
3 7 2007.36 31 14.69 2934 2 3
4 13 1674.04 18 14.68 2567 2 3
5 13 1145.52 18 14.70 1912 2 3
6 13 618.80 18 14.78 1227 2 4
7 13 153.60 18 14.91 543 2 3
8 13 86.84 18 14.92 441 2 3
9 8 0.24 175 14.92 296 2 7

Cycle 129 GMT 20/ 2/2022 4:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 33 14.90 429 2 2
2 12 1171.96 2 15.08 2023 2 2
3 7 2009.64 31 14.69 2938 2 2
4 13 1522.60 18 14.69 2381 2 3
5 13 1186.16 18 14.70 1957 2 3
6 13 518.48 18 14.80 1093 2 4
7 13 187.04 18 14.89 599 2 3
8 13 99.52 18 14.91 462 2 3
9 8 0.08 175 14.91 298 2 8

Cycle 128 GMT 10/ 2/2022 6: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 33 14.89 443 2 2
2 12 1160.72 2 15.08 2012 2 2
3 7 2004.00 31 14.69 2940 2 3
4 13 1680.00 18 14.67 2560 2 3
5 13 1153.64 18 14.70 1915 2 3
6 13 484.40 18 14.81 1040 2 4
7 13 178.44 18 14.90 584 2 3
8 13 60.76 18 14.93 398 2 3
9 8 0.20 175 14.91 295 2 9
10 14 0.20 15 14.89 294 2 9

Cycle 127 GMT 31/ 1/2022 7:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 33 14.88 436 2 2
2 12 1179.16 2 15.07 2034 2 2
3 7 2008.40 31 14.68 2937 2 2
4 13 1527.12 18 14.68 2384 2 3
5 13 1037.08 18 14.71 1779 2 3
6 13 542.04 18 14.79 1120 2 4
7 13 129.48 18 14.92 504 2 3
8 13 78.48 18 14.92 425 2 3
9 8 0.16 175 14.91 297 2 7

Cycle 126 GMT 21/ 1/2022 9:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 33 14.89 429 2 2
2 12 1172.92 2 15.07 2019 2 2
3 7 2004.80 31 14.69 2939 2 3
4 13 1520.64 18 14.70 2377 2 3
5 13 1031.48 18 14.72 1769 2 4
6 13 524.96 18 14.80 1097 2 4
7 13 177.64 18 14.90 590 2 3
8 13 56.84 18 14.93 401 2 3
9 8 0.08 175 14.91 301 2 9

Cycle 125 GMT 11/ 1/2022 11:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 33 14.88 443 2 2
2 12 1182.68 2 15.07 2041 2 2
3 7 2008.08 31 14.68 2935 2 3
4 13 1684.80 18 14.67 2579 2 3
5 13 1003.96 18 14.73 1734 2 3
6 13 502.48 18 14.81 1071 2 4
7 13 160.68 18 14.90 567 2 3
8 13 50.88 18 14.94 394 2 3
9 8 0.12 175 14.91 301 2 10

Cycle 124 GMT 1/ 1/2022 13:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 33 14.89 441 2 2
2 12 1168.36 2 15.08 2034 2 2
3 7 2010.44 32 14.68 2944 2 2
4 13 1537.68 18 14.69 2401 2 3
5 13 1037.16 18 14.71 1774 2 4
6 13 511.60 18 14.80 1086 2 5
7 13 170.16 18 14.90 580 2 3
8 13 58.52 18 14.93 404 2 3
9 8 0.00 175 14.91 300 2 7

Cycle 123 GMT 22/12/2021 15: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 33 14.89 445 2 2
2 12 1157.00 2 15.08 2015 2 2
3 7 2005.08 31 14.69 2929 2 3
4 13 1674.96 18 14.68 2570 2 3
5 13 1148.00 18 14.70 1917 2 3
6 13 620.88 18 14.78 1236 2 4
7 13 163.40 18 14.91 560 2 3
8 13 93.40 18 14.92 456 2 3
9 8 0.04 175 14.92 296 2 8

Cycle 122 GMT 12/12/2021 16:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 33 14.89 435 2 2
2 12 1160.52 2 15.08 2019 2 2
3 7 2006.08 31 14.69 2933 2 3
4 13 1542.44 18 14.69 2409 2 3
5 13 1037.64 18 14.72 1770 2 3
6 13 530.40 18 14.80 1108 2 4
7 13 182.88 18 14.90 603 2 3
8 13 59.96 18 14.93 403 2 3
9 8 0.12 175 14.92 300 2 8

Cycle 121 GMT 2/12/2021 18:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 33 14.89 441 2 2
2 12 1159.52 2 15.08 2019 2 2
3 7 2002.72 31 14.70 2926 2 3
4 13 1528.32 18 14.70 2379 2 3
5 13 1048.56 18 14.72 1779 2 3
6 13 539.68 18 14.80 1120 2 4
7 13 196.48 18 14.90 614 2 3
8 13 65.72 18 14.94 408 2 3
9 13 19.20 18 14.94 336 2 3
10 8 0.00 175 14.91 297 2 5

Cycle 120 GMT 22/11/2021 20:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 33 14.89 443 2 2
2 12 1173.76 2 15.08 2017 2 2
3 7 2013.04 31 14.69 2950 2 2
4 13 1544.60 18 14.69 2399 2 3
5 13 1210.56 18 14.69 1988 2 3
6 13 534.12 18 14.81 1111 2 4
7 13 192.80 18 14.90 609 2 3
8 13 99.24 18 14.92 462 2 3
9 8 0.04 175 14.92 297 2 9

Cycle 119 GMT 12/11/2021 22:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 33 14.90 435 2 2
2 12 1156.32 2 15.09 1987 2 2
3 7 2010.64 31 14.69 2943 2 3
4 13 1539.52 18 14.69 2398 2 3
5 13 1044.60 18 14.73 1775 2 3
6 13 533.76 18 14.81 1111 2 4
7 13 137.80 18 14.92 515 2 3
8 13 79.52 18 14.93 427 2 3
9 8 0.04 175 14.92 296 2 8

Cycle 118 GMT 3/11/2021 0:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 33 14.90 443 2 2
2 12 1166.56 2 15.08 2010 2 2
3 7 2006.08 32 14.69 2931 2 3
4 13 1668.56 18 14.69 2564 2 3
5 13 1149.64 18 14.71 1917 2 3
6 13 609.64 18 14.79 1227 2 4
7 13 155.76 18 14.93 547 2 3
8 13 91.60 18 14.94 455 2 3
9 8 0.12 175 14.93 295 2 11
10 14 0.12 15 14.91 298 2 8

Cycle 117 GMT 24/10/2021 2:13: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 33 14.89 449 2 2
2 12 1187.48 2 15.08 2054 2 2
3 7 2006.20 31 14.70 2942 2 2
4 13 1696.64 18 14.68 2587 2 3
5 13 1027.32 18 14.74 1755 2 3
6 13 536.84 18 14.81 1116 2 5
7 13 195.44 18 14.91 618 2 3
8 13 70.60 18 14.94 421 2 3
9 8 0.12 175 14.93 300 2 9

Cycle 116 GMT 14/10/2021 3:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 33 14.90 446 2 2
2 12 1161.68 2 15.08 2018 2 2
3 7 2008.68 31 14.69 2936 2 3
4 13 1539.28 18 14.69 2414 2 3
5 13 1036.56 18 14.73 1775 2 4
6 13 527.36 18 14.81 1100 2 3
7 13 174.24 18 14.91 586 2 3
8 13 58.44 18 14.95 406 2 3
9 8 0.12 175 14.93 302 2 9

Cycle 115 GMT 4/10/2021 5:37: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 33 14.89 443 2 2
2 12 1170.92 2 15.08 2033 2 2
3 7 2006.16 31 14.69 2939 2 3
4 13 1528.88 18 14.70 2385 2 3
5 13 1038.76 18 14.73 1772 2 3
6 13 513.84 18 14.82 1088 2 4
7 13 182.52 18 14.91 604 2 3
8 13 101.88 18 14.93 472 2 3
9 8 0.00 175 14.92 304 2 8

Cycle 114 GMT 24/ 9/2021 7:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 33 14.90 444 2 2
2 12 1184.04 2 15.08 2071 2 2
3 7 2010.88 32 14.69 2945 2 3
4 13 1531.16 18 14.70 2395 2 3
5 13 1042.76 18 14.73 1788 2 3
6 13 516.68 18 14.82 1093 2 4
7 13 175.44 18 14.92 584 2 3
8 13 95.48 18 14.93 461 2 3
9 8 0.08 175 14.93 304 2 9

Cycle 113 GMT 14/ 9/2021 9:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 33 14.90 447 2 2
2 12 1171.04 2 15.08 2011 2 2
3 7 2002.40 31 14.70 2931 2 3
4 13 1525.84 18 14.70 2387 2 3
5 13 1046.64 18 14.73 1792 2 3
6 13 545.64 18 14.81 1126 2 4
7 13 127.88 18 14.94 514 2 3
8 13 75.04 18 14.94 426 2 3
9 8 0.04 175 14.93 301 2 9

Cycle 112 GMT 4/ 9/2021 11:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 33 14.89 434 2 2
2 12 1177.44 2 15.08 2041 2 2
3 7 2006.80 32 14.69 2943 2 2
4 13 1533.12 18 14.70 2398 2 3
5 13 1037.76 18 14.73 1773 2 3
6 13 519.28 18 14.82 1095 2 4
7 13 124.88 18 14.94 502 2 3
8 13 81.40 18 14.95 432 2 3
9 8 0.04 175 14.93 301 2 9

Cycle 111 GMT 25/ 8/2021 12:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 33 14.91 427 2 2
2 12 1167.76 2 15.09 2042 2 2
3 7 2006.52 31 14.70 2941 2 2
4 13 1703.64 18 14.68 2607 2 3
5 13 1014.76 18 14.74 1753 2 3
6 13 521.88 18 14.82 1099 2 4
7 13 182.80 18 14.91 607 2 3
8 13 74.56 18 14.94 426 2 3
9 13 18.00 18 14.95 337 2 3
10 8 0.20 175 14.92 300 2 8

Cycle 110 GMT 15/ 8/2021 14:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 33 14.90 452 2 2
2 12 1163.08 2 15.10 2010 2 2
3 7 2005.40 31 14.70 2926 2 3
4 13 1531.52 18 14.71 2393 2 3
5 13 1050.16 18 14.73 1782 2 4
6 13 527.60 18 14.82 1109 2 4
7 13 123.80 18 14.94 498 2 3
8 13 79.68 18 14.95 432 2 3
9 13 23.56 18 14.95 343 2 3
10 8 0.12 175 14.93 296 2 9

Cycle 109 GMT 5/ 8/2021 15:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 32 14.90 436 2 2
2 12 1188.80 2 15.09 2041 2 2
3 7 2004.00 31 14.70 2936 2 2
4 13 1667.88 18 14.69 2564 2 3
5 13 985.44 18 14.75 1706 2 3
6 13 495.60 18 14.84 1057 2 4
7 13 166.12 18 14.93 572 2 3
8 13 93.44 18 14.94 457 2 3
9 8 0.08 175 14.94 299 2 9

Cycle 108 GMT 26/ 7/2021 17:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 32 14.91 448 2 2
2 12 1177.76 2 15.10 2035 2 2
3 7 2006.16 31 14.71 2941 2 3
4 13 1533.88 18 14.71 2402 2 3
5 13 1055.36 18 14.74 1792 2 3
6 13 540.76 18 14.82 1123 2 4
7 13 201.52 18 14.91 623 2 3
8 13 82.52 18 14.95 430 2 3
9 13 21.28 18 14.96 336 2 3
10 8 0.28 175 14.92 295 2 11

Cycle 107 GMT 16/ 7/2021 19:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 32 14.91 429 2 2
2 12 1171.76 2 15.09 2030 2 2
3 7 2003.96 31 14.70 2944 2 2
4 13 1537.40 18 14.71 2401 2 3
5 13 1042.20 18 14.74 1782 2 3
6 13 558.08 18 14.82 1145 2 4
7 13 137.24 18 14.94 525 2 3
8 13 78.08 18 14.96 427 2 3
9 8 0.08 175 14.94 300 2 5

Cycle 106 GMT 6/ 7/2021 21: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 32 14.91 446 2 2
2 12 1170.96 2 15.09 2012 2 2
3 7 2009.88 31 14.71 2944 2 3
4 13 1531.12 18 14.71 2390 2 3
5 13 1190.60 18 14.72 1960 2 3
6 13 646.28 18 14.80 1265 2 4
7 13 159.04 18 14.93 556 2 3
8 13 83.52 18 14.95 440 2 3
9 8 0.00 175 14.94 302 2 7

Cycle 105 GMT 26/ 6/2021 22:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 32 14.91 440 2 2
2 12 1176.40 2 15.08 2043 2 2
3 7 2002.60 31 14.70 2931 2 3
4 13 1671.80 18 14.69 2567 2 3
5 13 1124.16 18 14.73 1881 2 3
6 13 449.92 18 14.86 994 2 4
7 13 152.08 18 14.94 561 2 3
8 13 80.96 18 14.96 441 2 3
9 13 22.16 18 14.96 347 2 3
10 8 0.16 175 14.94 301 2 10

Cycle 104 GMT 17/ 6/2021 0:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 32 14.91 449 2 2
2 12 1178.68 2 15.10 2049 2 2
3 7 2013.00 32 14.70 2947 2 3
4 13 1542.52 18 14.70 2417 2 3
5 13 1043.80 18 14.74 1782 2 3
6 13 521.40 18 14.83 1099 2 4
7 13 112.56 18 14.95 489 2 3
8 13 65.68 18 14.96 413 2 3
9 8 0.24 175 14.94 303 2 11

Cycle 103 GMT 7/ 6/2021 2:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 32 14.91 443 2 2
2 12 1170.40 2 15.10 2029 2 2
3 7 1843.84 31 14.75 2756 2 3
4 13 1690.16 18 14.72 2575 2 3
5 13 1167.16 18 14.75 1951 2 3
6 13 479.60 18 14.87 1041 2 5
7 13 161.04 18 14.95 569 2 3
8 13 83.40 18 14.96 445 2 3
9 13 22.68 18 14.98 348 2 3
10 8 0.08 175 14.94 303 2 9

Cycle 102 GMT 28/ 5/2021 2: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 32 14.91 450 2 2
2 12 1165.48 2 15.09 2022 2 2
3 7 2005.88 31 14.71 2941 2 2
4 13 1532.20 18 14.72 2399 2 3
5 13 1058.32 18 14.74 1805 2 4
6 13 548.68 18 14.83 1135 2 4
7 13 131.20 18 14.95 520 2 3
8 13 70.52 18 14.96 422 2 3
9 13 17.20 18 14.97 340 2 3
10 8 0.00 175 14.94 303 2 11

Cycle 101 GMT 18/ 5/2021 3:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 32 14.91 448 2 2
2 12 1161.88 2 15.10 2047 2 2
3 7 2003.32 31 14.72 2937 2 2
4 13 1679.68 18 14.70 2573 2 3
5 13 1012.56 18 14.76 1755 2 4
6 13 502.72 18 14.85 1075 2 4
7 13 174.16 18 14.94 587 2 3
8 13 66.48 18 14.97 416 2 3
9 13 37.04 18 14.97 369 2 3
10 8 0.08 175 14.94 302 2 11

Cycle 100 GMT 8/ 5/2021 5:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 32 14.92 443 2 2
2 12 1176.12 2 15.10 2036 2 2
3 7 2003.24 31 14.71 2939 2 3
4 13 1532.96 18 14.72 2391 2 3
5 13 1056.12 18 14.74 1800 2 3
6 13 558.36 18 14.83 1152 2 5
7 13 198.08 18 14.92 628 2 3
8 13 69.60 18 14.96 424 2 3
9 13 38.88 18 14.96 374 2 3
10 8 0.12 175 14.94 303 2 11

Cycle 99 GMT 28/ 4/2021 7:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 32 14.92 446 2 2
2 12 1185.20 2 15.09 2047 2 2
3 7 2004.76 31 14.71 2937 2 3
4 13 1693.36 18 14.70 2587 2 3
5 13 1150.52 18 14.73 1919 2 3
6 13 476.32 18 14.85 1042 2 4
7 13 166.28 18 14.95 573 2 3
8 13 87.92 18 14.96 452 2 3
9 13 26.12 18 14.97 353 2 3
10 8 0.00 175 14.94 303 2 9

Cycle 98 GMT 18/ 4/2021 9:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 32 14.91 451 2 2
2 12 1157.32 2 15.10 2011 2 2
3 7 2008.84 31 14.71 2950 2 2
4 13 1689.48 18 14.70 2584 2 3
5 13 1172.60 18 14.73 1949 2 3
6 13 629.04 18 14.81 1243 2 4
7 13 167.44 18 14.95 566 2 3
8 13 93.56 18 14.96 454 2 3
9 13 25.28 18 14.98 342 2 3
10 8 0.12 175 14.95 296 2 6

Cycle 97 GMT 8/ 4/2021 11:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 32 14.93 438 2 2
2 12 1158.44 2 15.11 2013 2 2
3 7 2006.68 31 14.72 2948 2 3
4 13 1533.36 18 14.72 2392 2 3
5 13 1055.52 18 14.75 1803 2 3
6 13 525.16 18 14.84 1102 2 4
7 13 189.60 18 14.93 611 2 3
8 13 99.52 18 14.95 465 2 3
9 13 25.00 18 14.97 351 2 3
10 8 0.04 175 14.94 301 2 9

Cycle 96 GMT 29/ 3/2021 13:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 32 14.93 447 2 2
2 12 1172.36 2 15.09 2036 2 2
3 7 2003.36 31 14.72 2943 2 3
4 13 1664.24 18 14.71 2557 2 3
5 13 1149.96 18 14.74 1924 2 3
6 13 487.60 18 14.86 1048 2 4
7 13 175.08 18 14.95 590 2 3
8 13 97.72 18 14.96 463 2 3
9 13 27.40 18 14.98 350 2 3
10 8 -0.04 175 14.95 297 2 9

Cycle 95 GMT 19/ 3/2021 15: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 32 14.92 447 2 2
2 12 1154.44 2 15.11 2029 2 2
3 7 2012.88 31 14.72 2954 2 3
4 13 1549.92 18 14.72 2416 2 3
5 13 1067.12 18 14.75 1814 2 3
6 13 555.88 18 14.83 1145 2 4
7 13 207.28 18 14.93 639 2 3
8 13 75.00 18 14.97 427 2 3
9 13 40.92 18 14.98 371 2 3
10 8 0.08 175 14.95 297 2 7

Cycle 94 GMT 9/ 3/2021 16:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 32 14.93 443 2 2
2 12 1182.56 2 15.10 2052 2 2
3 7 2002.36 31 14.71 2943 2 2
4 13 1515.76 18 14.73 2388 2 3
5 13 1032.00 18 14.76 1773 2 4
6 13 515.80 18 14.85 1092 2 4
7 13 171.20 18 14.95 586 2 3
8 13 90.32 18 14.96 453 2 3
9 13 51.08 18 14.97 391 2 3
10 8 0.12 175 14.95 303 2 11

Cycle 93 GMT 27/ 2/2021 18:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 32 14.93 458 2 2
2 12 1159.76 2 15.11 2009 2 2
3 7 2003.24 31 14.73 2940 2 3
4 13 1679.56 18 14.71 2579 2 3
5 13 1151.44 18 14.75 1925 2 3
6 13 474.04 18 14.87 1033 2 5
7 13 163.16 18 14.96 569 2 3
8 13 86.08 18 14.98 446 2 3
9 13 25.28 18 14.99 347 2 3
10 8 0.00 175 14.96 299 2 11

Cycle 92 GMT 17/ 2/2021 20:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 32 14.93 443 2 2
2 12 1179.44 2 15.10 2030 2 2
3 7 2005.76 31 14.73 2944 2 3
4 13 1543.56 18 14.73 2405 2 3
5 13 1062.72 18 14.76 1807 2 3
6 13 532.80 18 14.85 1117 2 5
7 13 187.24 18 14.95 610 2 3
8 13 98.12 18 14.97 474 2 3
9 8 0.16 175 14.96 301 2 8

Cycle 91 GMT 7/ 2/2021 22:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 32 14.94 450 2 2
2 12 1180.92 2 15.11 2063 2 2
3 7 2004.48 31 14.73 2940 2 3
4 13 1536.48 18 14.73 2403 2 3
5 13 1209.32 18 14.74 1997 2 3
6 13 502.24 18 14.86 1071 2 4
7 13 168.12 18 14.96 582 2 3
8 13 74.56 18 14.99 429 2 3
9 13 42.84 18 14.99 379 2 3
10 8 0.04 175 14.96 300 2 9

Cycle 90 GMT 29/ 1/2021 0:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 32 14.93 445 2 2
2 12 1151.24 2 15.12 1999 2 2
3 7 2009.32 31 14.72 2944 2 3
4 13 1531.40 18 14.74 2390 2 3
5 13 1201.92 18 14.74 1973 2 3
6 13 513.08 18 14.86 1087 2 5
7 13 178.24 18 14.95 597 2 3
8 13 92.76 18 14.97 464 2 3
9 8 0.20 175 14.97 304 2 10
10 14 0.20 15 14.95 303 3 11

Cycle 89 GMT 19/ 1/2021 2: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 32 14.94 450 2 2
2 12 1183.40 2 15.10 2051 2 2
3 7 2006.64 31 14.72 2950 2 3
4 13 1531.96 18 14.73 2390 2 3
5 13 1019.28 18 14.78 1747 2 4
6 13 487.32 18 14.87 1051 2 4
7 13 156.28 18 14.97 569 2 3
8 13 82.56 18 14.98 450 2 3
9 13 19.96 18 15.00 348 2 3
10 8 0.04 175 14.96 310 2 11

Cycle 88 GMT 9/ 1/2021 4: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 14.94 441 2 2
2 12 1186.00 2 15.11 2048 2 2
3 7 2004.40 31 14.72 2935 2 3
4 13 1519.04 18 14.74 2374 2 3
5 13 1015.96 18 14.78 1750 2 3
6 13 503.52 18 14.87 1072 2 4
7 13 155.52 18 14.96 566 2 3
8 13 56.44 18 14.99 406 2 3
9 8 0.16 175 14.97 304 2 12

Cycle 87 GMT 30/12/2020 5:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 32 14.94 442 2 2
2 12 1172.60 2 15.12 2016 2 2
3 7 2003.72 31 14.73 2928 2 2
4 13 1675.36 18 14.72 2563 2 2
5 13 1013.60 18 14.78 1741 2 3
6 13 508.36 18 14.87 1090 2 4
7 13 111.40 18 14.99 501 2 3
8 13 69.44 18 14.99 428 2 3
9 13 17.16 18 15.00 342 2 3
10 8 0.12 175 14.97 306 2 13

Cycle 86 GMT 20/12/2020 7:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 32 14.96 432 2 2
2 12 1173.28 2 15.11 2033 2 2
3 7 2003.52 32 14.72 2938 2 3
4 13 1685.16 18 14.71 2577 2 3
5 13 1139.04 18 14.76 1909 2 3
6 13 459.60 18 14.88 1016 2 5
7 13 142.60 18 14.98 545 2 3
8 13 51.20 18 15.00 400 2 3
9 8 0.08 175 14.98 304 2 10

Cycle 85 GMT 10/12/2020 9:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 32 14.97 441 2 2
2 12 1168.44 2 15.12 2021 2 2
3 7 2008.44 31 14.72 2939 2 3
4 13 1509.00 18 14.75 2375 2 3
5 13 1028.68 18 14.78 1763 2 3
6 13 370.80 18 14.91 893 2 4
7 13 119.60 18 14.99 507 2 3
8 13 64.64 18 15.00 418 2 3
9 8 0.12 175 14.98 302 2 11

Cycle 84 GMT 30/11/2020 11: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 32 14.96 442 2 2
2 12 1175.92 2 15.12 2045 2 2
3 7 2006.60 31 14.73 2946 2 3
4 13 1522.04 18 14.75 2382 2 3
5 13 1023.92 18 14.79 1758 2 3
6 13 509.60 18 14.88 1084 2 4
7 13 116.36 18 14.99 496 2 3
8 13 71.36 18 15.00 430 2 3
9 8 0.16 175 14.99 302 2 10

Cycle 83 GMT 20/11/2020 12:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 32 14.96 440 2 2
2 12 1150.72 2 15.12 2006 2 2
3 7 2007.16 31 14.73 2938 2 3
4 13 1520.56 18 14.75 2379 2 3
5 13 1185.64 18 14.75 1964 2 3
6 13 474.20 18 14.89 1036 2 4
7 13 147.96 18 14.98 557 2 3
8 13 57.12 18 15.01 404 2 3
9 8 0.04 175 14.99 302 2 9

Cycle 82 GMT 10/11/2020 14:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 14.96 446 2 2
2 12 1161.92 2 15.13 2031 2 2
3 7 2002.12 32 14.73 2934 2 2
4 13 1524.96 18 14.74 2393 2 3
5 13 1019.88 18 14.79 1761 2 3
6 13 498.00 18 14.89 1068 2 4
7 13 100.52 18 15.01 481 2 3
8 13 57.16 18 15.01 408 2 3
9 8 0.04 175 14.99 306 2 9

Cycle 81 GMT 31/10/2020 16:19:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 32 14.97 433 2 2
2 12 1168.48 2 15.12 2034 2 2
3 7 2002.36 31 14.74 2941 2 2
4 13 1517.24 18 14.75 2379 2 3
5 13 1022.56 18 14.79 1757 2 3
6 13 509.48 18 14.89 1086 2 4
7 13 110.48 18 15.01 494 2 3
8 13 63.04 18 15.01 418 2 3
9 8 0.12 175 14.99 306 2 10

Cycle 80 GMT 21/10/2020 18: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 32 14.96 447 2 2
2 12 1188.60 2 15.12 2045 2 2
3 7 2011.00 31 14.74 2954 2 2
4 13 1511.72 18 14.76 2371 2 3
5 13 1018.24 18 14.80 1759 2 4
6 13 519.28 18 14.88 1092 2 4
7 13 165.76 18 14.99 585 2 3
8 13 61.64 18 15.02 416 2 3
9 13 33.68 18 15.02 367 2 3
10 8 0.04 175 14.99 305 2 7

Cycle 79 GMT 11/10/2020 19:31:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 32 14.98 446 2 2
2 12 1180.20 2 15.13 2039 2 2
3 7 2004.24 31 14.74 2944 2 3
4 13 1668.84 18 14.74 2560 2 3
5 13 968.24 18 14.81 1695 2 4
6 13 475.56 18 14.90 1037 2 5
7 13 150.16 18 14.99 562 2 3
8 13 54.64 18 15.02 407 2 3
9 8 0.04 175 15.00 307 2 8

Cycle 78 GMT 1/10/2020 21:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 14.98 458 2 2
2 12 1172.12 2 15.14 2039 2 2
3 7 2002.28 32 14.74 2935 2 3
4 13 1677.36 18 14.73 2574 2 3
5 13 995.56 18 14.81 1719 2 3
6 13 502.92 18 14.90 1075 2 4
7 13 110.32 18 15.02 490 2 3
8 13 68.48 18 15.03 422 2 3
9 8 0.04 175 15.01 302 2 10

Cycle 77 GMT 21/ 9/2020 23:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 32 14.98 454 2 2
2 12 1165.24 2 15.13 2017 2 2
3 7 2006.32 31 14.75 2943 2 3
4 13 1687.76 18 14.73 2592 2 3
5 13 1152.16 18 14.78 1922 2 3
6 13 623.84 18 14.87 1235 2 4
7 13 144.12 18 15.01 546 2 3
8 13 56.76 18 15.03 405 2 3
9 8 0.08 175 15.01 303 2 8

Cycle 76 GMT 12/ 9/2020 1:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 14.99 448 2 2
2 12 1165.52 2 15.15 2019 2 2
3 7 2011.16 31 14.74 2945 2 3
4 13 1550.76 18 14.75 2425 2 3
5 13 1050.32 18 14.79 1794 2 3
6 13 529.20 18 14.89 1110 2 5
7 13 118.04 18 15.02 495 2 3
8 13 66.08 18 15.03 420 2 3
9 8 0.20 175 15.01 304 2 9

Cycle 75 GMT 2/ 9/2020 2:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 32 14.99 435 2 2
2 12 1173.36 2 15.14 2023 2 2
3 7 2004.08 31 14.75 2945 2 3
4 13 1682.96 18 14.74 2579 2 3
5 13 980.20 18 14.82 1706 2 3
6 13 492.44 18 14.91 1067 2 5
7 13 152.08 18 15.01 563 2 3
8 13 61.36 18 15.04 412 2 3
9 8 0.16 175 15.02 302 2 10

Cycle 74 GMT 23/ 8/2020 4:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 32 14.99 446 2 2
2 12 1170.80 2 15.15 2017 2 2
3 7 1983.00 31 14.74 2923 2 3
4 13 1510.32 18 14.76 2384 2 3
5 13 1023.04 18 14.80 1761 2 3
6 13 367.32 18 14.94 893 2 5
7 13 121.04 18 15.03 510 2 3
8 13 68.28 18 15.04 421 2 3
9 8 0.16 175 15.02 303 2 11

Cycle 73 GMT 13/ 8/2020 3:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 32 15.00 449 2 2
2 12 1179.68 2 15.15 2050 2 2
3 7 2002.56 31 14.76 2943 2 3
4 13 1521.28 18 14.77 2387 2 3
5 13 1016.56 18 14.81 1754 2 3
6 13 493.52 18 14.92 1059 2 4
7 13 156.88 18 15.02 570 2 3
8 13 46.04 18 15.05 395 2 3
9 8 0.08 175 15.02 309 2 7

Cycle 72 GMT 3/ 8/2020 5:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 32 15.01 435 2 2
2 12 1176.92 2 15.15 2034 2 2
3 7 2007.20 32 14.74 2949 2 3
4 13 1680.92 18 14.74 2581 2 3
5 13 988.92 18 14.82 1725 2 4
6 13 486.80 18 14.92 1056 2 4
7 13 153.24 18 15.02 568 2 3
8 13 48.88 18 15.05 403 2 3
9 8 0.00 175 15.03 309 2 10

Cycle 71 GMT 24/ 7/2020 5:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 32 15.01 458 2 2
2 12 1165.72 2 15.14 2018 2 2
3 7 2005.88 31 14.75 2943 2 2
4 13 1525.68 18 14.77 2397 2 3
5 13 1028.64 18 14.82 1763 2 3
6 13 508.80 18 14.92 1078 2 5
7 13 109.92 18 15.05 486 2 3
8 13 66.20 18 15.06 416 2 3
9 8 0.04 175 15.04 301 2 8

Cycle 70 GMT 14/ 7/2020 6:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 32 15.02 432 2 2
2 12 1170.96 2 15.15 2036 2 2
3 7 2004.12 31 14.76 2941 2 3
4 13 1519.44 18 14.78 2376 2 3
5 13 1033.96 18 14.82 1774 2 3
6 13 535.72 18 14.92 1120 2 4
7 13 117.00 18 15.04 505 2 3
8 13 63.16 18 15.05 421 2 3
9 8 0.04 175 15.04 309 2 9

Cycle 69 GMT 4/ 7/2020 8:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 32 15.01 443 2 2
2 12 1189.68 2 15.14 2038 2 2
3 7 2002.08 31 14.76 2929 2 2
4 13 1507.52 18 14.78 2376 2 3
5 13 1004.04 18 14.83 1731 2 3
6 13 503.80 18 14.93 1071 2 6
7 13 108.64 18 15.06 485 2 3
8 13 64.84 18 15.06 414 2 3
9 8 0.36 175 15.05 303 2 5

Cycle 68 GMT 24/ 6/2020 10:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 32 15.02 435 2 2
2 12 1179.60 2 15.15 2037 2 2
3 7 2002.88 32 14.76 2938 2 2
4 13 1675.52 18 14.76 2569 2 2
5 13 992.88 18 14.84 1710 2 3
6 13 469.92 18 14.95 1016 2 4
7 13 144.60 18 15.04 550 2 3
8 13 59.16 18 15.06 410 2 3
9 13 32.96 18 15.06 368 2 3
10 8 0.04 175 15.04 305 2 8

Cycle 67 GMT 14/ 6/2020 12:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 32 15.03 444 2 2
2 12 1172.28 2 15.16 2041 2 2
3 7 2003.80 31 14.77 2943 2 3
4 13 1385.32 18 14.80 2223 2 3
5 13 1070.80 18 14.82 1808 2 3
6 13 544.40 18 14.92 1128 2 5
7 13 122.24 18 15.06 507 2 3
8 13 67.52 18 15.07 423 2 3
9 13 37.12 18 15.07 370 2 3
10 8 0.12 175 15.05 301 2 6
11 14 0.12 15 15.03 301 3 9

Cycle 66 GMT 4/ 6/2020 13:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 15.03 431 2 2
2 12 1155.88 2 15.15 2013 2 2
3 7 2007.68 32 14.77 2935 2 3
4 13 1519.08 18 14.78 2379 2 3
5 13 1019.60 18 14.83 1752 2 3
6 13 357.64 18 14.99 863 2 4
7 13 122.52 18 15.07 508 2 3
8 13 67.60 18 15.08 428 2 3
9 13 16.92 18 15.09 335 2 3
10 8 0.00 175 15.05 302 2 8

Cycle 65 GMT 25/ 5/2020 15:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 31 15.03 432 2 2
2 12 1166.00 2 15.16 2006 2 2
3 7 2004.16 31 14.78 2938 2 2
4 13 1668.00 18 14.77 2562 2 3
5 13 1140.80 18 14.81 1919 2 3
6 13 477.36 18 14.96 1031 2 4
7 13 155.48 18 15.06 562 2 3
8 13 80.48 18 15.07 442 2 3
9 13 20.28 18 15.09 346 2 3
10 8 0.04 175 15.05 304 2 12

Cycle 64 GMT 15/ 5/2020 17:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 31 15.03 443 2 2
2 12 1173.60 2 15.16 2021 2 2
3 7 2007.80 31 14.78 2943 2 2
4 13 1538.60 18 14.79 2397 2 3
5 13 1036.40 18 14.84 1772 2 3
6 13 518.52 18 14.95 1090 2 4
7 13 169.92 18 15.06 591 2 3
8 13 62.28 18 15.09 413 2 3
9 13 36.48 18 15.09 367 2 3
10 8 0.08 175 15.06 301 2 11

Cycle 63 GMT 5/ 5/2020 19: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 31 15.04 437 2 2
2 12 1172.04 2 15.18 2011 2 2
3 7 2003.12 31 14.78 2932 2 3
4 13 1533.24 18 14.79 2394 2 3
5 13 1034.24 18 14.84 1774 2 3
6 13 530.68 18 14.95 1110 2 4
7 13 121.08 18 15.08 505 2 3
8 13 64.36 18 15.09 413 2 3
9 13 17.48 18 15.10 338 2 3
10 8 0.04 175 15.06 300 2 10

Cycle 62 GMT 25/ 4/2020 20:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 31 15.06 445 2 2
2 12 1171.84 2 15.16 2037 2 2
3 7 2002.92 31 14.78 2935 2 3
4 13 1519.40 18 14.80 2393 2 3
5 13 1024.52 18 14.85 1756 2 3
6 13 502.16 18 14.97 1070 2 5
7 13 155.08 18 15.07 570 2 3
8 13 61.12 18 15.09 413 2 3
9 13 17.96 18 15.10 342 2 3
10 8 0.04 175 15.07 305 2 9

Cycle 61 GMT 15/ 4/2020 22:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 31 15.05 447 2 2
2 12 1178.72 2 15.16 2045 2 2
3 7 2003.16 31 14.78 2936 2 3
4 13 1516.48 18 14.79 2375 2 3
5 13 1019.44 18 14.85 1745 2 3
6 13 507.76 18 14.97 1080 2 5
7 13 112.00 18 15.09 493 2 3
8 13 43.92 18 15.11 384 2 3
9 8 0.08 175 15.09 303 2 10

Cycle 60 GMT 6/ 4/2020 0:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 31 15.06 444 2 2
2 12 1169.88 2 15.18 2031 2 2
3 7 2004.44 32 14.78 2945 2 2
4 13 1509.60 18 14.80 2375 2 3
5 13 879.72 18 14.89 1570 2 3
6 13 530.32 18 14.97 1117 2 4
7 13 107.04 18 15.09 488 2 3
8 13 60.68 18 15.10 413 2 3
9 13 33.96 18 15.10 367 2 3
10 8 0.08 175 15.08 304 2 11

Cycle 59 GMT 27/ 3/2020 2:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 15.07 446 2 2
2 12 1186.84 2 15.17 2057 2 2
3 7 2005.24 31 14.79 2943 2 3
4 13 1527.96 18 14.80 2399 2 3
5 13 1034.76 18 14.86 1776 2 3
6 13 510.08 18 14.98 1083 2 6
7 13 106.92 18 15.10 491 2 3
8 13 61.76 18 15.11 417 2 3
9 13 19.80 18 15.12 349 2 3
10 8 0.12 175 15.09 306 2 10

Cycle 58 GMT 17/ 3/2020 4: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 31 15.07 440 2 2
2 12 1191.96 2 15.16 2055 2 2
3 7 2003.28 31 14.78 2937 2 2
4 13 1660.64 18 14.79 2549 2 3
5 13 997.68 18 14.88 1725 2 3
6 13 329.28 18 15.04 830 2 3
7 13 106.16 18 15.11 491 2 3
8 13 34.84 18 15.13 377 2 3
9 8 0.20 175 15.10 307 2 9

Cycle 57 GMT 7/ 3/2020 5:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 31 15.08 445 2 2
2 12 1168.04 2 15.19 2020 2 2
3 7 2007.08 31 14.79 2943 2 3
4 13 1534.00 18 14.81 2395 2 3
5 13 1024.80 18 14.87 1761 2 3
6 13 355.28 18 15.04 867 2 4
7 13 104.68 18 15.11 494 2 3
8 13 33.88 18 15.13 375 2 3
9 8 0.16 175 15.10 307 2 11

Cycle 56 GMT 26/ 2/2020 7:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 15.08 443 2 2
2 12 1179.88 2 15.18 2050 2 2
3 7 2005.20 31 14.79 2942 2 3
4 13 1524.80 18 14.81 2384 2 3
5 13 1010.72 18 14.88 1739 2 3
6 13 497.68 18 14.99 1060 2 4
7 13 101.72 18 15.12 487 2 3
8 13 39.72 18 15.13 384 2 3
9 8 0.08 175 15.11 309 2 9

Cycle 55 GMT 16/ 2/2020 9: 5: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 31 15.08 443 2 2
2 12 1175.12 2 15.18 2046 2 2
3 7 2005.96 32 14.78 2935 2 3
4 13 1514.80 18 14.81 2380 2 3
5 13 1003.00 18 14.88 1741 2 3
6 13 347.64 18 15.05 858 2 4
7 13 101.04 18 15.12 488 2 3
8 13 35.32 18 15.14 385 2 3
9 8 0.04 175 15.11 307 2 8

Cycle 54 GMT 6/ 2/2020 10:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 15.08 451 2 2
2 12 1161.00 2 15.18 2021 2 2
3 7 2002.32 31 14.79 2941 2 3
4 13 1522.56 18 14.81 2398 2 3
5 13 1043.56 18 14.88 1782 2 3
6 13 379.72 18 15.04 905 2 4
7 13 114.68 18 15.12 512 2 3
8 13 35.56 18 15.14 389 2 3
9 8 0.08 175 15.11 313 2 11

Cycle 53 GMT 27/ 1/2020 12: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 15.09 449 2 2
2 12 1156.52 2 15.18 2001 2 2
3 7 2008.44 31 14.79 2955 2 3
4 13 1523.08 18 14.81 2390 2 3
5 13 887.00 18 14.92 1582 2 3
6 13 405.52 18 15.03 945 2 4
7 13 119.44 18 15.12 516 2 3
8 13 41.40 18 15.14 391 2 3
9 8 0.20 175 15.12 306 2 11

Cycle 52 GMT 17/ 1/2020 13:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 31 15.09 444 2 2
2 12 1173.40 2 15.19 2019 2 2
3 7 2003.16 31 14.80 2939 2 3
4 13 1675.16 18 14.80 2570 2 3
5 13 1131.12 18 14.86 1899 2 3
6 13 615.60 18 14.97 1224 2 5
7 13 129.48 18 15.12 531 2 3
8 13 43.16 18 15.14 390 2 3
9 8 0.08 175 15.12 307 2 10

Cycle 51 GMT 7/ 1/2020 15:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 31 15.10 438 2 2
2 12 1155.52 2 15.20 2013 2 2
3 7 2010.08 31 14.80 2944 2 3
4 13 1536.72 18 14.82 2398 2 3
5 13 1035.36 18 14.89 1769 2 3
6 13 364.12 18 15.06 877 2 4
7 13 111.08 18 15.13 496 2 3
8 13 62.08 18 15.14 420 2 3
9 8 0.12 175 15.12 308 2 11

Cycle 50 GMT 28/12/2019 17: 2: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 15.10 438 2 2
2 12 1157.48 2 15.20 2005 2 2
3 7 2005.16 31 14.80 2934 2 3
4 13 1670.60 18 14.80 2561 2 3
5 13 984.56 18 14.91 1707 2 3
6 13 469.56 18 15.03 1022 2 4
7 13 138.20 18 15.13 542 2 3
8 13 42.36 18 15.15 387 2 3
9 8 0.12 175 15.13 307 2 11

Cycle 49 GMT 18/12/2019 18:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 31 15.10 443 2 2
2 12 1184.76 2 15.20 2046 2 2
3 7 2003.08 31 14.81 2944 2 2
4 13 1508.04 18 14.83 2371 2 3
5 13 1174.28 18 14.86 1953 2 3
6 13 460.80 18 15.03 1013 2 4
7 13 151.84 18 15.13 561 2 3
8 13 50.20 18 15.16 395 2 3
9 13 15.12 18 15.16 338 2 3
10 8 0.04 175 15.13 304 2 10

Cycle 48 GMT 8/12/2019 20:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 31 15.11 437 2 2
2 12 1182.72 2 15.20 2063 2 2
3 7 2003.00 31 14.81 2950 2 3
4 13 1497.68 18 14.83 2357 2 3
5 13 1018.08 18 14.91 1751 2 3
6 13 492.16 18 15.03 1058 2 4
7 13 109.80 18 15.15 488 2 3
8 13 68.40 18 15.16 418 2 3
9 13 19.20 18 15.16 339 2 3
10 8 0.12 175 15.13 300 2 10

Cycle 47 GMT 28/11/2019 22:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 15.12 428 2 2
2 12 1159.60 2 15.20 2012 2 2
3 7 2007.56 32 14.81 2949 2 3
4 13 1514.32 18 14.84 2376 2 3
5 13 995.92 18 14.92 1730 2 3
6 13 363.44 18 15.07 881 2 4
7 13 116.52 18 15.15 502 2 3
8 13 63.20 18 15.16 416 2 3
9 8 0.16 175 15.14 304 2 12

Cycle 46 GMT 18/11/2019 23:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 31 15.11 451 2 2
2 12 1168.28 2 15.19 2031 2 2
3 7 2004.24 31 14.80 2949 2 3
4 13 1693.56 18 14.80 2594 2 3
5 13 993.16 18 14.92 1723 2 3
6 13 488.64 18 15.04 1052 2 4
7 13 145.80 18 15.14 554 2 3
8 13 55.48 18 15.17 407 2 3
9 8 0.16 175 15.15 304 2 10

Cycle 45 GMT 9/11/2019 1:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 31 15.12 441 2 2
2 12 1163.36 2 15.21 2010 2 2
3 7 2005.08 31 14.81 2951 2 3
4 13 1687.24 18 14.81 2588 2 3
5 13 991.88 18 14.92 1716 2 4
6 13 468.36 18 15.04 1028 2 4
7 13 139.80 18 15.14 544 2 3
8 13 48.80 18 15.17 398 2 3
9 8 0.12 175 15.15 307 2 10

Cycle 44 GMT 30/10/2019 3:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 31 15.12 437 2 2
2 12 1163.68 2 15.21 2019 2 2
3 7 2005.64 31 14.82 2944 2 2
4 13 1489.24 18 14.86 2342 2 3
5 13 1144.32 18 14.89 1911 2 3
6 13 451.92 18 15.06 1006 2 4
7 13 137.84 18 15.15 541 2 3
8 13 51.76 18 15.17 401 2 3
9 8 0.08 175 15.15 304 2 13

Cycle 43 GMT 20/10/2019 5: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 31 15.12 445 2 2
2 12 1172.64 2 15.21 2033 2 2
3 7 2008.96 31 14.82 2942 2 3
4 13 1548.92 18 14.85 2409 2 3
5 13 1039.12 18 14.92 1779 2 3
6 13 379.40 18 15.08 901 2 4
7 13 126.84 18 15.16 520 2 3
8 13 67.80 18 15.17 427 2 3
9 8 0.16 175 15.15 306 2 11

Cycle 42 GMT 10/10/2019 6:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 15.13 453 2 2
2 12 1166.60 2 15.22 2032 2 2
3 7 2006.80 32 14.82 2943 2 3
4 13 1517.40 18 14.85 2373 2 3
5 13 1021.04 18 14.93 1749 2 3
6 13 491.32 18 15.05 1056 2 5
7 13 145.60 18 15.15 558 2 3
8 13 50.76 18 15.17 402 2 3
9 8 0.04 175 15.16 306 2 9

Cycle 41 GMT 30/ 9/2019 8:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 31 15.14 425 2 2
2 12 1177.20 2 15.22 2033 2 2
3 7 2001.92 31 14.83 2928 2 3
4 13 1491.40 18 14.87 2349 2 3
5 13 986.84 18 14.94 1715 2 3
6 13 458.96 18 15.07 1020 2 4
7 13 142.48 18 15.16 548 2 3
8 13 54.88 18 15.18 404 2 3
9 8 0.08 175 15.16 305 2 9

Cycle 40 GMT 20/ 9/2019 9:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 31 15.14 450 2 2
2 12 1168.08 2 15.23 2032 2 2
3 7 2004.36 31 14.84 2944 2 3
4 13 1523.84 18 14.86 2374 2 3
5 13 1020.80 18 14.93 1755 2 3
6 13 353.20 18 15.11 865 2 4
7 13 119.44 18 15.18 501 2 3
8 13 69.76 18 15.18 416 2 3
9 8 0.08 175 15.17 302 2 11

Cycle 39 GMT 10/ 9/2019 11:30: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 15.14 446 2 2
2 12 1164.72 2 15.23 2039 2 2
3 7 2004.68 31 14.84 2933 2 3
4 13 1498.20 18 14.87 2350 2 3
5 13 985.32 18 14.95 1702 2 3
6 13 472.84 18 15.06 1029 2 5
7 13 140.24 18 15.16 548 2 3
8 13 52.64 18 15.18 403 2 3
9 8 0.08 175 15.17 308 2 8

Cycle 38 GMT 31/ 8/2019 13: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 15.15 451 2 2
2 12 1169.76 2 15.23 2031 2 2
3 7 2005.28 32 14.83 2944 2 3
4 13 1484.08 18 14.88 2332 2 3
5 13 971.20 18 14.95 1690 2 3
6 13 447.04 18 15.08 1000 2 5
7 13 130.28 18 15.17 538 2 3
8 13 45.12 18 15.19 396 2 3
9 8 0.24 175 15.17 309 2 11

Cycle 37 GMT 21/ 8/2019 14:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 31 15.14 454 2 2
2 10 1000.48 2 15.14 1760 2 2
3 3 940.88 -1 15.48 0 2 2
4 12 1138.12 2 15.23 1964 2 2
5 7 2004.44 31 14.84 2947 2 3
6 13 1526.12 18 14.87 2381 2 3
7 13 1012.96 18 14.95 1742 2 4
8 13 357.24 18 15.11 865 2 4
9 13 117.32 18 15.18 504 2 3
10 13 69.20 18 15.19 425 2 3
11 8 0.08 175 15.17 308 2 10

Cycle 36 GMT 11/ 8/2019 16:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 31 15.14 449 2 2
2 12 1163.00 2 15.23 2010 2 2
3 7 2001.72 31 14.85 2940 2 3
4 13 1530.64 18 14.87 2402 2 3
5 13 1046.92 18 14.94 1781 2 3
6 13 508.12 18 15.06 1083 2 5
7 13 108.48 18 15.19 489 2 3
8 13 63.80 18 15.20 415 2 3
9 8 0.12 175 15.18 306 2 9

Cycle 35 GMT 1/ 8/2019 18: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 31 15.15 446 2 2
2 12 1171.88 2 15.23 2022 2 2
3 7 2004.28 31 14.83 2943 2 2
4 13 1674.40 18 14.85 2571 2 3
5 13 975.08 18 14.97 1699 2 3
6 13 461.64 18 15.08 1018 2 5
7 13 133.48 18 15.18 544 2 3
8 13 70.60 18 15.19 439 2 3
9 13 17.32 18 15.20 350 2 3
10 8 -0.04 175 15.17 312 2 6

Cycle 34 GMT 22/ 7/2019 19:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 31 15.16 444 2 2
2 12 1177.60 2 15.23 2046 2 2
3 7 2003.44 31 14.85 2942 2 3
4 13 1519.32 18 14.88 2386 2 3
5 13 1010.28 18 14.96 1741 2 4
6 13 340.52 18 15.12 846 2 4
7 13 114.76 18 15.19 504 2 3
8 13 61.92 18 15.20 418 2 3
9 8 0.00 175 15.18 309 2 11

Cycle 33 GMT 12/ 7/2019 21:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 15.16 447 2 2
2 12 1181.12 2 15.21 2052 2 2
3 7 2005.40 31 14.85 2948 2 2
4 13 1537.96 18 14.88 2416 2 3
5 13 1040.16 18 14.95 1775 2 3
6 13 372.60 18 15.12 897 2 4
7 13 117.16 18 15.19 505 2 3
8 13 65.48 18 15.20 424 2 3
9 8 0.12 175 15.19 305 2 11

Cycle 32 GMT 2/ 7/2019 22:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 31 15.16 454 2 2
2 12 1163.76 2 15.24 2039 2 2
3 7 2007.80 31 14.85 2949 2 3
4 13 1506.36 18 14.89 2361 2 3
5 13 989.68 18 14.97 1713 2 3
6 13 457.72 18 15.09 1011 2 4
7 13 141.00 18 15.18 547 2 3
8 13 57.08 18 15.21 407 2 3
9 8 0.08 175 15.19 306 2 9

Cycle 31 GMT 23/ 6/2019 0:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 31 15.17 453 2 2
2 12 1168.84 2 15.24 2023 2 2
3 7 2003.88 31 14.86 2945 2 2
4 13 1517.88 18 14.89 2379 2 3
5 13 1006.32 18 14.97 1742 2 3
6 13 510.72 18 15.08 1082 2 4
7 13 103.60 18 15.20 484 2 3
8 13 62.04 18 15.21 416 2 3
9 8 0.08 175 15.19 309 2 8

Cycle 30 GMT 13/ 6/2019 2: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 31 15.17 451 2 2
2 12 1174.68 2 15.25 2026 2 2
3 7 2006.84 31 14.86 2946 2 2
4 13 1507.32 18 14.89 2368 2 3
5 13 1011.72 18 14.97 1745 2 3
6 13 495.68 18 15.09 1064 2 3
7 13 107.44 18 15.20 491 2 3
8 13 67.80 18 15.21 429 2 3
9 8 0.16 175 15.19 311 2 11

Cycle 29 GMT 3/ 6/2019 3:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 31 15.17 440 2 2
2 12 1165.56 2 15.25 2037 2 2
3 7 2001.64 31 14.86 2938 2 3
4 13 1517.44 18 14.90 2381 2 3
5 13 1027.04 18 14.97 1764 2 4
6 13 386.76 18 15.13 915 2 4
7 13 126.92 18 15.20 523 2 3
8 13 67.44 18 15.21 429 2 3
9 8 0.08 175 15.20 308 2 11

Cycle 28 GMT 24/ 5/2019 5:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 31 15.17 455 2 2
2 12 1154.40 2 15.25 2011 2 2
3 7 2007.32 31 14.87 2947 2 2
4 13 1519.40 18 14.90 2381 2 3
5 13 1030.72 18 14.97 1769 2 3
6 13 373.40 18 15.13 891 2 3
7 13 121.04 18 15.21 510 2 3
8 13 70.20 18 15.22 433 2 3
9 8 0.08 175 15.21 308 2 11

Cycle 27 GMT 14/ 5/2019 6:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 15.18 448 2 2
2 12 1159.24 2 15.26 2004 2 2
3 7 2003.56 31 14.87 2939 2 3
4 13 1526.72 18 14.90 2385 2 3
5 13 890.32 18 15.02 1581 2 3
6 13 561.04 18 15.08 1149 2 4
7 13 118.76 18 15.21 507 2 3
8 13 66.64 18 15.22 425 2 3
9 8 0.08 175 15.20 307 2 10

Cycle 26 GMT 4/ 5/2019 8: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 30 15.18 447 2 2
2 12 1156.56 2 15.26 2016 2 2
3 7 1950.40 31 14.88 2876 2 2
4 13 1620.76 18 14.90 2510 2 3
5 13 960.00 18 15.01 1682 2 3
6 13 435.72 18 15.12 982 2 3
7 13 129.08 18 15.21 532 2 3
8 13 44.72 18 15.23 395 2 3
9 8 0.20 175 15.21 311 2 8

Cycle 25 GMT 24/ 4/2019 7:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 30 15.18 448 2 2
2 12 1162.68 2 15.26 2012 2 2
3 7 2006.12 31 14.87 2943 2 3
4 13 1519.12 18 14.91 2379 2 3
5 13 1039.32 18 14.98 1782 2 3
6 13 363.36 18 15.14 876 2 3
7 13 108.84 18 15.22 499 2 3
8 13 60.28 18 15.23 422 2 3
9 8 0.08 175 15.21 314 2 10

Cycle 24 GMT 14/ 4/2019 8:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 30 15.19 450 2 2
2 12 1169.96 2 15.26 2034 2 2
3 7 2005.56 32 14.87 2948 2 3
4 13 1532.88 18 14.91 2398 2 3
5 13 1001.52 18 15.00 1731 2 3
6 13 328.60 18 15.16 826 2 4
7 13 94.40 18 15.23 476 2 3
8 13 60.24 18 15.23 420 2 3
9 8 0.12 175 15.21 310 2 9

Cycle 23 GMT 4/ 4/2019 10: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 30 15.19 451 2 2
2 12 1158.68 2 15.27 2001 2 2
3 7 2003.52 31 14.88 2947 2 3
4 13 1516.20 18 14.92 2378 2 3
5 13 1024.68 18 14.99 1760 2 3
6 13 473.64 18 15.12 1038 2 4
7 13 98.64 18 15.23 480 2 3
8 13 59.48 18 15.24 418 2 3
9 8 0.08 175 15.22 309 2 9

Cycle 22 GMT 25/ 3/2019 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 30 15.19 452 2 2
2 12 1168.84 2 15.27 2025 2 2
3 7 2003.36 31 14.88 2946 2 2
4 13 1699.56 18 14.89 2595 2 3
5 13 1007.12 18 15.00 1736 2 3
6 13 330.64 18 15.16 834 2 4
7 13 101.52 18 15.23 487 2 3
8 13 55.08 18 15.24 411 2 3
9 8 0.08 175 15.22 309 2 11

Cycle 21 GMT 15/ 3/2019 13:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 30 15.20 437 2 2
2 12 1152.88 2 15.27 1994 2 2
3 7 2005.48 31 14.89 2949 2 3
4 13 1522.12 18 14.92 2383 2 3
5 13 1006.00 18 15.01 1735 2 3
6 13 485.76 18 15.12 1052 2 4
7 13 152.28 18 15.21 569 2 3
8 13 48.12 18 15.24 399 2 3
9 8 0.04 165 15.22 309 2 10

Cycle 20 GMT 5/ 3/2019 14:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 30 15.20 437 2 2
2 12 1187.48 2 15.28 2042 2 2
3 7 2003.48 31 14.89 2944 2 2
4 13 1513.68 18 14.93 2378 2 3
5 13 996.56 18 15.01 1720 2 3
6 13 350.60 18 15.17 861 2 4
7 13 112.40 18 15.23 497 2 3
8 13 61.08 18 15.25 417 2 3
9 8 0.08 165 15.23 307 2 11

Cycle 19 GMT 23/ 2/2019 15:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 15.20 451 2 2
2 12 1158.96 2 15.28 2018 2 2
3 7 2003.40 31 14.89 2946 2 3
4 13 1501.92 19 14.93 2363 2 3
5 13 978.36 19 15.01 1694 2 4
6 13 287.16 19 15.19 768 2 4
7 13 85.04 19 15.25 460 2 3
8 13 48.48 19 15.25 396 2 3
9 8 0.08 165 15.23 314 2 12

Cycle 18 GMT 13/ 2/2019 17: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 30 15.21 451 2 2
2 12 1170.08 2 15.27 2051 2 2
3 7 2003.48 32 14.89 2940 2 2
4 13 1499.68 19 14.93 2359 2 3
5 13 845.56 19 15.05 1528 2 4
6 13 339.92 19 15.17 845 2 4
7 13 95.12 19 15.24 475 2 3
8 13 53.20 19 15.24 407 2 3
9 8 0.08 165 15.23 314 2 10

Cycle 17 GMT 3/ 2/2019 18:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 15.21 453 2 2
2 12 1181.28 2 15.28 2050 2 2
3 7 2001.76 31 14.90 2943 2 2
4 13 1511.60 19 14.94 2378 2 3
5 13 996.08 19 15.01 1723 2 3
6 13 314.88 19 15.18 812 2 4
7 13 98.64 19 15.25 477 2 3
8 13 54.80 19 15.25 405 2 3
9 8 0.04 165 15.24 307 2 10

Cycle 16 GMT 24/ 1/2019 19:35: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 30 15.22 442 2 2
2 12 1168.92 2 15.28 2022 2 2
3 7 2002.96 31 14.91 2939 2 2
4 13 1524.68 19 14.94 2385 2 3
5 13 870.08 19 15.05 1555 2 4
6 13 375.08 19 15.16 895 2 4
7 13 107.28 19 15.24 494 2 3
8 13 58.48 19 15.25 417 2 3
9 8 0.12 165 15.24 311 2 9

Cycle 15 GMT 14/ 1/2019 21: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 30 15.21 439 2 2
2 12 1163.32 2 15.29 1992 2 2
3 7 2006.48 32 14.90 2940 2 3
4 13 1506.56 22 14.94 2359 2 3
5 13 822.04 22 15.06 1492 2 4
6 13 163.32 22 15.24 581 2 3
7 13 54.60 22 15.27 408 2 3
8 8 0.12 165 15.25 309 2 9

Cycle 14 GMT 4/ 1/2019 22:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 30 15.21 442 2 2
2 12 1147.48 2 15.30 1986 2 2
3 7 2003.72 31 14.91 2941 2 2
4 13 1512.00 22 14.94 2359 2 3
5 13 829.80 22 15.06 1503 2 4
6 13 287.28 22 15.19 767 2 3
7 13 67.92 22 15.26 433 2 3
8 13 18.84 22 15.27 350 2 3
9 8 0.08 165 15.23 312 2 8
10 14 0.08 25 15.21 309 2 10

Cycle 13 GMT 26/12/2018 0: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 30 15.22 451 2 2
2 12 1160.92 2 15.30 2004 2 2
3 7 2002.20 31 14.93 2939 2 2
4 13 1490.64 22 14.95 2337 2 3
5 13 798.16 22 15.07 1458 2 4
6 13 255.60 22 15.21 721 2 3
7 13 65.60 22 15.26 431 2 3
8 13 17.40 22 15.27 353 2 3
9 8 0.08 165 15.24 314 2 11

Cycle 12 GMT 16/12/2018 1:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 30 15.22 449 2 2
2 12 1181.92 2 15.30 2071 2 2
3 7 2003.08 31 14.91 2944 2 2
4 13 1512.36 22 14.95 2368 2 3
5 13 827.48 22 15.06 1498 2 4
6 13 169.36 22 15.24 587 2 3
7 13 61.76 22 15.27 413 2 3
8 8 0.12 165 15.25 307 2 8

Cycle 11 GMT 6/12/2018 2:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 30 15.22 448 2 2
2 12 1179.56 2 15.30 2036 2 2
3 7 2006.56 31 14.92 2949 2 2
4 13 1375.56 22 14.98 2196 2 3
5 13 877.28 22 15.05 1564 2 3
6 13 182.84 22 15.24 603 2 3
7 13 70.84 22 15.27 426 2 3
8 8 0.12 165 15.26 306 2 7

Cycle 10 GMT 26/11/2018 4: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 30 15.22 442 2 2
2 12 1171.08 2 15.31 2019 2 2
3 7 2005.32 31 14.92 2949 2 2
4 13 1515.52 22 14.95 2378 2 3
5 13 843.44 22 15.06 1519 2 3
6 13 286.56 22 15.20 766 2 4
7 13 74.12 22 15.26 441 2 3
8 8 0.20 165 15.25 313 2 7

Cycle 9 GMT 16/11/2018 4:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 29 15.23 448 2 2
2 12 1309.04 2 15.27 2217 2 2
3 7 2000.56 31 14.92 2943 2 2
4 13 1485.92 21 14.96 2336 2 3
5 13 804.08 21 15.08 1465 2 3
6 13 266.04 21 15.21 738 2 3
7 13 73.80 21 15.27 441 2 3
8 13 18.88 21 15.28 349 2 3
9 8 0.00 165 15.25 312 2 11

Cycle 8 GMT 6/11/2018 6: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 15.23 436 2 2
2 12 1181.64 2 15.32 2049 2 2
3 7 2002.48 31 14.94 2941 2 2
4 13 1526.60 21 14.96 2380 2 3
5 13 839.12 21 15.07 1514 2 3
6 13 190.32 21 15.25 612 2 3
7 13 104.96 21 15.26 481 2 3
8 13 25.20 21 15.28 355 2 3
9 8 0.04 165 15.26 306 2 9

Cycle 7 GMT 27/10/2018 7:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 29 15.23 448 2 2
2 12 1329.72 2 15.28 2234 2 2
3 7 2000.76 31 14.94 2944 2 2
4 13 1501.56 21 14.97 2358 2 3
5 13 832.36 21 15.07 1507 2 3
6 13 287.60 21 15.21 769 2 4
7 13 87.36 21 15.27 456 2 3
8 13 22.88 21 15.28 353 2 3
9 8 -0.04 165 15.25 308 2 10

Cycle 6 GMT 17/10/2018 8: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 28 15.23 445 2 2
2 10 1027.20 2 15.21 1795 2 2
3 7 2005.60 38 14.91 2925 2 2
4 13 1179.60 18 15.04 1944 2 3
5 13 724.56 18 15.11 1362 2 4
6 13 234.76 18 15.23 687 2 3
7 13 123.72 18 15.26 511 2 3
8 13 34.76 18 15.28 371 2 3
9 8 0.04 165 15.26 306 2 9

Cycle 5 GMT 7/10/2018 9:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 28 15.25 433 2 2
2 7 2003.68 39 14.92 2918 2 2
3 13 1345.56 18 15.01 2157 2 3
4 13 830.84 18 15.09 1499 2 3
5 13 295.52 18 15.22 775 2 3
6 13 100.12 18 15.28 470 2 3
7 13 54.84 18 15.28 397 2 3
8 8 0.08 165 15.27 306 2 8

Cycle 4 GMT 27/ 9/2018 11:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 15.26 439 2 2
2 7 1506.04 38 15.06 2311 2 2
3 13 1360.92 18 15.06 2156 2 3
4 13 669.60 18 15.16 1277 2 3
5 13 185.68 18 15.27 604 2 3
6 13 105.52 18 15.29 477 2 3
7 13 25.60 18 15.31 354 2 3
8 8 0.08 165 15.28 303 2 8

Cycle 3 GMT 26/ 9/2018 11: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 28 15.26 440 2 2
2 7 1527.08 38 15.06 2329 2 2
3 13 1210.76 18 15.08 1964 2 3
4 13 559.20 18 15.18 1128 2 3
5 13 214.56 18 15.26 649 2 3
6 13 84.92 18 15.30 439 2 3
7 8 0.16 165 15.29 297 2 7

Cycle 2 GMT 25/ 9/2018 10:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 15.29 441 2 2
2 7 1509.32 38 15.08 2303 2 2
3 13 1206.92 18 15.09 1946 2 3
4 13 699.20 18 15.16 1305 2 3
5 13 188.00 18 15.29 600 2 3
6 13 106.80 18 15.30 469 2 3
7 13 27.40 18 15.31 346 2 2
8 8 0.08 165 15.29 296 2 9

Cycle 1 GMT 24/ 9/2018 10:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.48 393 2 3
2 7 997.20 74 15.16 1641 3 3
3 13 45.60 18 15.37 387 2 3
4 8 0.08 240 15.34 305 2 16

Cycle 0 GMT 23/ 9/2018 23:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.04 22 15.64 333 3 3
2 7 81.00 74 15.61 361 3 3
3 13 50.36 18 15.59 307 2 3
4 8 0.36 240 15.56 233 2 10