SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 6077 WMO= 5906415


Cycle 149 GMT 17/12/2024 6:53: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.2 8 98 14.95 437 2 6
2 6 5406.2 553 167 14.31 3808 2 32
3 3 3499.2 914 16 14.86 2649 2 36
4 7 2948.5 12843 80 14.93 2311 2 38
5 13 2001.9 13059 80 14.86 1724 2 40
6 13 1256.6 13191 80 14.86 1258 2 40
7 13 1000.6 13227 80 14.85 1096 2 38
8 13 732.4 13257 80 14.85 919 2 36
9 14 0.9 13336 129 14.96 412 2 154

Cycle 148 GMT 7/12/2024 0: 9: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.2 8 98 14.94 441 2 8
2 6 5406.5 572 167 14.30 3799 2 30
3 3 3480.8 933 15 14.86 2634 2 35
4 7 2926.3 12843 80 14.94 2302 2 38
5 13 2028.4 13047 80 14.86 1758 2 37
6 13 1532.7 13131 80 14.81 1451 2 40
7 13 954.3 13209 80 14.87 1066 2 36
8 13 723.9 13235 80 14.86 922 2 37
9 14 0.9 13314 129 14.96 422 2 127

Cycle 147 GMT 26/11/2024 17:29: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.5 8 98 14.95 436 2 9
2 6 5404.2 558 167 14.30 3785 2 31
3 3 3476.9 919 15 14.87 2628 2 35
4 7 2902.8 12843 80 14.95 2274 2 38
5 13 1995.4 13047 80 14.87 1734 2 39
6 13 1248.2 13179 80 14.86 1263 2 38
7 13 995.8 13215 80 14.84 1101 2 37
8 13 717.6 13248 80 14.86 914 2 35
9 14 0.8 13325 127 14.96 419 2 135

Cycle 146 GMT 16/11/2024 10:51:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.3 8 98 14.94 438 2 9
2 6 5407.6 575 168 14.31 3790 2 31
3 3 3466.6 936 14 14.87 2629 2 34
4 7 2902.2 12843 80 14.95 2285 2 39
5 13 1997.0 13041 80 14.88 1728 2 39
6 13 1304.0 13161 80 14.85 1302 2 38
7 13 882.9 13221 80 14.88 1025 2 36
8 13 734.0 13238 80 14.85 920 2 36
9 14 0.4 13318 127 14.96 412 2 166

Cycle 145 GMT 6/11/2024 4: 6: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.5 8 98 14.95 439 2 9
2 6 5407.7 558 167 14.31 3783 2 32
3 3 3520.8 919 17 14.86 2661 2 36
4 7 2927.4 12843 80 14.94 2298 2 39
5 13 2012.3 13053 80 14.88 1730 2 38
6 13 1284.2 13179 80 14.86 1275 2 39
7 13 991.5 13221 80 14.85 1084 2 37
8 13 734.5 13250 80 14.85 919 2 34
9 14 0.4 13330 129 14.96 413 2 156

Cycle 144 GMT 26/10/2024 21:22: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.3 8 97 14.94 435 2 6
2 6 5406.5 559 167 14.30 3798 2 31
3 3 3490.1 920 15 14.86 2643 2 34
4 7 2935.0 12843 80 14.95 2311 2 39
5 13 2051.1 13041 80 14.88 1769 2 39
6 13 1276.6 13179 80 14.86 1290 2 40
7 13 979.1 13221 80 14.85 1090 2 37
8 13 742.0 13248 80 14.85 930 2 37
9 14 0.5 13330 129 14.96 420 2 154

Cycle 143 GMT 16/10/2024 14:39: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.3 8 97 14.95 437 2 8
2 6 5406.0 589 167 14.30 3788 2 30
3 3 3482.3 950 15 14.86 2656 2 33
4 7 2936.1 12843 80 14.95 2299 2 39
5 13 2023.9 13053 80 14.88 1749 2 39
6 13 1248.7 13191 80 14.87 1266 2 39
7 13 992.5 13227 80 14.85 1090 2 38
8 13 732.2 13256 80 14.85 924 2 36
9 14 0.6 13335 129 14.96 414 2 123

Cycle 142 GMT 6/10/2024 7:21: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.1 8 97 14.95 436 2 8
2 6 5408.3 568 167 14.30 3783 2 31
3 3 3499.5 929 16 14.86 2633 2 36
4 7 2913.5 12843 80 14.96 2282 2 39
5 13 1992.2 13041 80 14.90 1719 2 39
6 13 1299.5 13161 80 14.88 1288 2 39
7 13 999.8 13203 80 14.87 1092 2 37
8 13 717.3 13235 80 14.87 910 2 35
9 14 0.5 13313 129 14.96 411 2 159

Cycle 141 GMT 26/ 9/2024 0:45: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.5 8 97 14.96 429 2 9
2 6 5406.7 571 167 14.32 3786 2 32
3 3 3477.7 932 15 14.87 2625 2 34
4 7 2923.8 12843 80 14.96 2293 2 40
5 13 1998.5 13053 80 14.89 1730 2 38
6 13 1297.3 13179 80 14.88 1284 2 39
7 13 997.4 13221 80 14.87 1099 2 37
8 13 735.0 13250 80 14.87 919 2 35
9 14 0.3 13330 127 14.97 410 2 108

Cycle 140 GMT 15/ 9/2024 17:51: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.7 8 96 14.95 451 2 9
2 6 5407.4 558 167 14.32 3783 2 32
3 3 3552.5 919 19 14.84 2676 2 36
4 7 2884.6 12843 80 14.96 2270 2 38
5 13 1996.9 13047 80 14.90 1721 2 40
6 13 1371.2 13155 80 14.88 1334 2 39
7 13 988.4 13209 80 14.88 1083 2 38
8 13 733.6 13238 80 14.87 915 2 36
9 14 0.2 13318 125 14.97 410 2 111

Cycle 139 GMT 5/ 9/2024 11:16: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.6 8 96 14.95 457 2 8
2 6 5406.4 578 166 14.32 3800 2 31
3 3 3477.2 939 15 14.86 2640 2 35
4 7 2917.8 12843 80 14.97 2287 2 40
5 13 1999.4 13041 80 14.90 1719 2 38
6 13 1331.4 13161 80 14.89 1303 2 38
7 13 996.6 13209 80 14.88 1094 2 37
8 13 732.0 13238 80 14.87 916 2 35
9 14 0.6 13317 129 14.96 416 2 160

Cycle 138 GMT 26/ 8/2024 4:20: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.3 8 97 14.95 455 2 11
2 6 4482.1 341 162 14.46 3223 2 31
3 7 3131.0 12482 80 14.94 2430 2 40
4 13 2168.8 12698 80 14.87 1833 2 38
5 13 1501.2 12818 80 14.85 1423 2 40
6 13 1000.2 12890 80 14.88 1104 2 37
7 13 724.3 12923 80 14.88 920 2 35
8 14 0.8 13004 142 14.96 431 2 117

Cycle 137 GMT 16/ 8/2024 0:41: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.7 8 97 14.96 432 2 8
2 6 5404.1 559 167 14.33 3783 2 32
3 3 3501.7 921 16 14.86 2643 2 35
4 7 2918.4 12843 80 14.97 2291 2 39
5 13 1984.8 13053 80 14.90 1715 2 39
6 13 1427.0 13149 80 14.87 1364 2 40
7 13 986.5 13209 80 14.89 1089 2 37
8 13 733.4 13238 80 14.88 920 2 35
9 14 0.4 13317 129 14.97 428 2 136

Cycle 136 GMT 5/ 8/2024 18:11: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.6 8 96 14.97 440 2 6
2 6 5407.1 573 168 14.33 3782 2 32
3 3 3481.0 934 15 14.86 2636 2 35
4 7 2942.4 12843 80 14.97 2299 2 39
5 13 2042.0 13047 80 14.90 1753 2 39
6 13 1266.7 13185 80 14.90 1266 2 39
7 13 970.1 13227 80 14.89 1074 2 37
8 13 735.1 13253 80 14.88 917 2 35
9 14 0.5 13333 129 14.97 411 2 113

Cycle 135 GMT 26/ 7/2024 11: 8: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 8 96 14.96 439 2 7
2 6 5407.9 551 167 14.32 3774 2 30
3 3 3506.6 912 16 14.86 2649 2 35
4 7 2922.8 12843 80 14.97 2297 2 39
5 13 2025.6 13041 80 14.90 1760 2 39
6 13 1415.6 13149 80 14.88 1374 2 40
7 13 996.6 13209 80 14.89 1102 2 37
8 13 736.2 13239 80 14.88 927 2 34
9 14 0.4 13318 129 14.97 422 2 106

Cycle 134 GMT 16/ 7/2024 4:43: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.0 8 97 14.97 432 2 9
2 6 4355.0 325 161 14.49 3115 2 31
3 7 3129.4 12482 80 14.95 2430 2 38
4 13 2169.5 12698 80 14.88 1834 2 40
5 13 1445.7 12830 80 14.87 1384 2 38
6 13 992.2 12896 80 14.89 1099 2 37
7 13 731.1 12926 80 14.89 923 2 35
8 14 0.6 13006 142 14.97 413 2 111

Cycle 133 GMT 6/ 7/2024 1:15: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 8 98 14.98 436 2 9
2 6 5261.8 542 166 14.35 3690 2 35
3 3 3392.8 903 10 14.90 2585 2 34
4 7 2985.1 12843 80 14.97 2334 2 38
5 13 2074.9 13047 80 14.90 1770 2 38
6 13 1475.3 13149 80 14.88 1399 2 40
7 13 967.4 13221 80 14.90 1075 2 36
8 13 736.3 13248 80 14.89 930 2 35
9 14 0.7 13330 133 14.98 415 2 132

Cycle 132 GMT 25/ 6/2024 18:46: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.0 8 98 14.97 438 2 7
2 6 5408.1 562 167 14.33 3796 2 33
3 3 3481.8 923 15 14.87 2649 2 34
4 7 2907.3 12843 80 14.98 2280 2 38
5 13 1982.4 13047 80 14.92 1708 2 39
6 13 1292.6 13167 80 14.91 1279 2 39
7 13 959.9 13215 80 14.90 1060 2 37
8 13 724.5 13241 80 14.89 905 2 35
9 14 0.4 13320 127 14.98 410 2 139

Cycle 131 GMT 15/ 6/2024 12: 9: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.4 8 97 14.97 428 2 7
2 6 5406.1 554 168 14.33 3788 2 32
3 3 3498.4 915 16 14.87 2658 2 34
4 7 2912.5 12843 80 14.98 2296 2 39
5 13 1996.1 13047 80 14.91 1740 2 38
6 13 1238.3 13185 80 14.91 1251 2 39
7 13 994.1 13221 80 14.89 1088 2 38
8 13 735.2 13250 80 14.89 920 2 36
9 14 0.8 13330 127 14.98 408 2 114

Cycle 130 GMT 5/ 6/2024 5:30: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.2 8 98 14.97 445 2 6
2 6 5404.5 552 167 14.33 3789 2 31
3 3 3455.7 914 13 14.88 2643 2 33
4 7 2929.1 12843 80 14.98 2304 2 38
5 13 1997.5 13053 80 14.92 1722 2 38
6 13 1298.7 13173 80 14.91 1289 2 38
7 13 999.3 13215 80 14.89 1098 2 37
8 13 711.6 13248 80 14.90 903 2 35
9 14 0.4 13323 129 14.98 413 2 134

Cycle 129 GMT 25/ 5/2024 23: 0: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.4 8 98 14.97 453 2 8
2 6 5406.4 582 167 14.33 3797 2 33
3 3 3485.0 943 15 14.87 2659 2 36
4 7 2891.0 12843 80 14.98 2285 2 39
5 13 1997.8 13035 80 14.92 1738 2 39
6 13 1254.5 13167 80 14.92 1261 2 39
7 13 996.1 13203 80 14.89 1094 2 37
8 13 732.2 13232 80 14.89 919 2 35
9 14 0.4 13312 127 14.98 410 2 149

Cycle 128 GMT 15/ 5/2024 16:13: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.8 8 97 14.96 458 2 7
2 6 5404.7 548 167 14.33 3792 2 33
3 3 3481.3 910 15 14.87 2649 2 35
4 7 2960.3 12843 80 14.97 2308 2 40
5 13 2000.7 13059 80 14.91 1721 2 38
6 13 1271.3 13191 80 14.91 1273 2 39
7 13 987.2 13233 80 14.90 1079 2 38
8 13 732.2 13262 80 14.89 915 2 35
9 14 0.9 13341 131 14.98 421 2 162

Cycle 127 GMT 5/ 5/2024 9:26: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.6 8 98 14.97 443 2 7
2 6 4150.6 282 160 14.52 3015 2 31
3 7 3144.5 12482 80 14.94 2435 2 37
4 13 2278.4 12674 80 14.87 1906 2 38
5 13 1553.9 12800 80 14.86 1466 2 40
6 13 971.3 12884 80 14.90 1093 2 37
7 13 733.6 12913 80 14.89 931 2 35
8 14 0.8 12996 144 14.98 421 2 109

Cycle 126 GMT 25/ 4/2024 6:55: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.9 8 99 14.97 434 2 6
2 6 4898.9 458 164 14.41 3456 2 34
3 3 3267.1 819 3 14.98 2625 2 32
4 7 3090.3 12843 80 14.96 2394 2 38
5 13 2239.2 13035 80 14.88 1884 2 38
6 13 1382.3 13185 80 14.90 1343 2 41
7 13 925.9 13251 80 14.91 1047 2 36
8 13 747.1 13272 80 14.89 941 2 35
9 14 0.7 13356 142 14.98 410 2 144

Cycle 125 GMT 15/ 4/2024 1:26: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.8 8 98 14.96 440 2 6
2 6 5407.5 573 167 14.32 3793 2 34
3 3 3478.0 935 15 14.86 2643 2 33
4 7 2930.6 12843 80 14.97 2320 2 40
5 13 2171.4 13011 80 14.89 1841 2 40
6 13 1352.1 13149 80 14.90 1331 2 39
7 13 965.8 13203 80 14.90 1081 2 37
8 13 735.0 13229 80 14.89 929 2 36
9 14 0.8 13312 131 14.98 414 2 152

Cycle 124 GMT 4/ 4/2024 18:47: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.0 8 100 14.97 441 2 6
2 6 3935.9 255 159 14.55 2883 2 31
3 7 3092.5 12482 80 14.95 2411 2 39
4 13 2148.9 12704 80 14.88 1831 2 39
5 13 1412.5 12836 80 14.88 1371 2 39
6 13 991.4 12896 80 14.89 1102 2 36
7 13 733.9 12926 80 14.89 921 2 35
8 14 0.8 13009 140 14.98 413 2 115

Cycle 123 GMT 25/ 3/2024 16:24: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.8 8 100 14.97 445 2 6
2 6 5406.6 568 168 14.33 3798 2 33
3 3 3487.1 930 15 14.86 2654 2 36
4 7 2898.6 12843 80 14.97 2280 2 39
5 13 1984.9 13047 80 14.91 1714 2 40
6 13 1272.2 13173 80 14.90 1272 2 39
7 13 982.7 13215 80 14.89 1087 2 38
8 13 742.7 13241 80 14.88 934 2 36
9 14 1.2 13324 129 14.98 409 2 154

Cycle 122 GMT 15/ 3/2024 9:30: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.9 8 100 14.96 434 2 5
2 6 5407.4 554 167 14.33 3782 2 33
3 3 3500.6 915 16 14.86 2659 2 36
4 7 2937.9 12843 80 14.96 2316 2 38
5 13 1988.6 13053 80 14.91 1728 2 39
6 13 1391.5 13155 80 14.88 1350 2 38
7 13 999.7 13209 80 14.88 1106 2 37
8 13 721.5 13242 80 14.88 914 2 36
9 14 0.6 13322 131 14.97 416 2 128

Cycle 121 GMT 5/ 3/2024 3: 0: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.5 8 99 14.96 441 2 6
2 6 5404.3 550 168 14.32 3785 2 34
3 3 3494.0 911 16 14.86 2640 2 35
4 7 2904.9 12843 80 14.97 2283 2 39
5 13 2096.0 13023 80 14.90 1790 2 39
6 13 1226.6 13173 80 14.90 1243 2 39
7 13 972.4 13209 80 14.88 1081 2 38
8 13 735.4 13236 80 14.87 935 2 36
9 14 1.4 13316 129 14.97 413 2 126

Cycle 120 GMT 23/ 2/2024 20:37: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.3 8 98 14.96 448 2 6
2 6 5406.4 542 167 14.32 3803 2 32
3 3 3537.8 903 18 14.84 2684 2 35
4 7 2937.5 12843 80 14.96 2316 2 39
5 13 2069.6 13035 80 14.90 1775 2 38
6 13 1298.0 13173 80 14.89 1302 2 38
7 13 957.1 13221 80 14.88 1086 2 36
8 13 719.1 13247 80 14.88 923 2 36
9 14 1.0 13325 129 14.97 412 2 106

Cycle 119 GMT 13/ 2/2024 14:15: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.9 8 98 14.95 443 2 5
2 6 5403.4 558 167 14.33 3783 2 32
3 3 3506.5 919 16 14.85 2663 2 36
4 7 2945.4 12843 80 14.97 2316 2 38
5 13 1999.4 13059 80 14.91 1740 2 39
6 13 1314.6 13179 80 14.89 1308 2 39
7 13 979.8 13227 80 14.88 1083 2 37
8 13 741.8 13254 80 14.87 936 2 35
9 14 1.1 13333 129 14.96 425 2 107

Cycle 118 GMT 3/ 2/2024 7:26: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.3 8 97 14.95 433 2 7
2 6 5404.7 544 167 14.32 3797 2 34
3 3 3523.6 905 17 14.83 2674 2 35
4 7 2941.0 12843 80 14.97 2309 2 38
5 13 2034.4 13047 80 14.91 1752 2 39
6 13 1276.2 13179 80 14.89 1277 2 39
7 13 937.7 13227 80 14.89 1056 2 37
8 13 731.9 13250 80 14.87 923 2 35
9 14 0.9 13329 131 14.96 416 2 145

Cycle 117 GMT 24/ 1/2024 0:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 8 96 14.96 448 2 7
2 6 5405.0 558 167 14.32 3800 2 34
3 3 3538.4 919 18 14.83 2677 2 35
4 7 2911.8 12843 80 14.97 2295 2 39
5 13 1989.4 13053 80 14.91 1724 2 39
6 13 1268.7 13179 80 14.90 1272 2 39
7 13 965.6 13221 80 14.88 1065 2 37
8 13 730.9 13248 80 14.87 920 2 36
9 14 1.5 13326 129 14.96 413 2 132

Cycle 116 GMT 13/ 1/2024 18:17: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.1 8 95 14.96 451 2 7
2 6 5409.0 558 167 14.32 3800 2 33
3 3 3543.3 919 18 14.82 2687 2 34
4 7 2920.5 12843 80 14.96 2314 2 38
5 13 1991.6 13047 80 14.91 1732 2 38
6 13 1244.3 13179 80 14.90 1265 2 39
7 13 987.0 13215 80 14.88 1084 2 37
8 13 730.8 13244 80 14.88 915 2 35
9 14 1.1 13323 129 14.96 412 2 124

Cycle 115 GMT 3/ 1/2024 11:39: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.5 8 95 14.96 440 2 6
2 6 5406.8 577 168 14.32 3793 2 33
3 3 3425.5 938 12 14.85 2611 2 34
4 7 2937.0 12843 80 14.97 2311 2 38
5 13 2063.0 13035 80 14.91 1774 2 38
6 13 1349.5 13161 80 14.89 1325 2 39
7 13 965.0 13215 80 14.89 1074 2 37
8 13 737.7 13241 80 14.88 921 2 35
9 14 0.7 13321 131 14.97 423 3 140

Cycle 114 GMT 24/12/2023 4:43:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 8 95 14.96 441 2 5
2 6 5404.4 563 167 14.32 3787 2 34
3 3 3477.3 925 15 14.83 2625 2 34
4 7 2930.5 12843 80 14.97 2304 2 39
5 13 1984.7 13053 80 14.92 1716 2 38
6 13 1300.3 13173 80 14.89 1291 2 38
7 13 965.1 13221 80 14.89 1075 2 36
8 13 732.6 13248 80 14.88 918 2 35
9 14 0.7 13326 131 14.97 418 2 145

Cycle 113 GMT 13/12/2023 22: 0: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.0 8 95 14.96 444 2 7
2 6 5404.9 545 167 14.32 3790 2 34
3 3 3500.3 907 16 14.82 2660 2 35
4 7 2929.3 12843 80 14.96 2307 2 40
5 13 1983.6 13059 80 14.91 1727 2 39
6 13 1421.5 13155 80 14.88 1376 2 39
7 13 985.7 13215 80 14.88 1086 2 38
8 13 733.1 13244 80 14.88 919 2 35
9 14 0.6 13323 132 14.97 417 2 164

Cycle 112 GMT 3/12/2023 15:37: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 8 94 14.96 436 2 8
2 6 5405.8 552 167 14.33 3779 2 32
3 3 3551.8 913 19 14.80 2675 2 34
4 7 2899.9 12843 80 14.97 2299 2 38
5 13 2003.0 13053 80 14.91 1735 2 39
6 13 1289.8 13179 80 14.90 1285 2 39
7 13 995.9 13221 80 14.88 1096 2 37
8 13 732.4 13250 80 14.88 914 2 35
9 14 1.1 13329 127 14.97 413 2 113

Cycle 111 GMT 23/11/2023 9: 2: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.7 8 94 14.96 448 2 8
2 6 5406.5 562 167 14.32 3798 2 31
3 3 3461.0 923 14 14.83 2647 2 34
4 7 2928.9 12843 80 14.97 2296 2 38
5 13 1994.6 13053 80 14.92 1721 2 39
6 13 1256.3 13185 80 14.90 1267 2 39
7 13 997.4 13221 80 14.88 1102 2 37
8 13 737.2 13251 80 14.88 917 2 35
9 14 0.6 13331 129 14.97 414 2 107

Cycle 110 GMT 13/11/2023 2:13: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.3 8 92 14.97 433 2 7
2 6 5408.0 540 167 14.32 3797 2 32
3 3 3519.7 901 17 14.81 2673 2 34
4 7 2970.9 12843 80 14.96 2341 2 37
5 13 2012.7 13053 80 14.91 1746 2 39
6 13 1313.4 13179 80 14.89 1305 2 38
7 13 970.3 13227 80 14.89 1080 2 37
8 13 731.3 13253 80 14.88 924 2 34
9 14 0.7 13334 133 14.97 417 2 140

Cycle 109 GMT 2/11/2023 19:34:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 8 93 14.97 447 2 6
2 6 4514.4 344 162 14.46 3246 2 33
3 7 3138.3 12482 80 14.93 2437 2 38
4 13 2154.6 12716 80 14.88 1841 2 38
5 13 1357.5 12860 80 14.88 1333 2 37
6 13 987.5 12914 80 14.89 1091 2 36
7 13 732.9 12944 80 14.88 924 2 34
8 14 0.5 13027 142 14.98 415 2 103

Cycle 108 GMT 23/10/2023 15:30: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.2 8 94 14.96 461 2 8
2 6 4855.3 417 164 14.40 3472 2 32
3 3 3288.7 778 4 14.89 2600 2 32
4 7 3088.5 12843 80 14.94 2405 2 38
5 13 2195.3 13053 80 14.88 1850 2 39
6 13 1609.2 13149 80 14.85 1485 2 39
7 13 979.6 13239 80 14.90 1087 2 37
8 13 746.4 13265 80 14.88 941 2 35
9 14 0.5 13349 142 14.98 416 2 111

Cycle 107 GMT 13/10/2023 10:47: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.6 8 94 14.96 454 2 6
2 6 5403.5 555 167 14.32 3791 2 31
3 3 3435.6 916 12 14.84 2647 2 32
4 7 2965.2 12843 80 14.96 2327 2 38
5 13 2018.3 13059 80 14.90 1748 2 37
6 13 1570.0 13137 80 14.85 1474 2 37
7 13 965.6 13221 80 14.89 1085 2 35
8 13 728.1 13248 80 14.88 921 2 33
9 14 0.5 13326 133 14.98 435 2 124

Cycle 106 GMT 3/10/2023 4:10: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.9 8 94 14.97 458 2 9
2 6 5408.2 554 167 14.32 3805 2 32
3 3 3511.3 915 17 14.81 2660 2 33
4 7 2881.7 12843 80 14.97 2283 2 38
5 13 2122.2 12999 80 14.91 1812 2 38
6 13 1372.9 13125 80 14.89 1346 2 38
7 13 982.5 13179 80 14.89 1095 2 36
8 13 740.7 13205 80 14.88 935 2 34
9 14 0.8 13284 129 14.97 427 2 145

Cycle 105 GMT 22/ 9/2023 22:15:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.4 8 94 14.97 443 2 9
2 6 5404.0 569 167 14.33 3795 2 33
3 3 3458.8 931 14 14.82 2664 2 34
4 7 2927.4 12843 80 14.97 2317 2 38
5 13 1985.2 13053 80 14.91 1728 2 38
6 13 1266.6 13179 80 14.90 1274 2 38
7 13 982.4 13221 80 14.89 1088 2 36
8 13 729.3 13250 80 14.88 920 2 35
9 14 0.8 13329 129 14.98 422 2 119

Cycle 104 GMT 12/ 9/2023 15:18:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 8 94 14.97 451 2 8
2 6 5404.2 577 167 14.33 3793 2 33
3 3 3479.5 939 15 14.82 2668 2 34
4 7 2899.6 12843 80 14.97 2288 2 38
5 13 2002.1 13047 80 14.91 1746 2 38
6 13 1301.3 13167 80 14.90 1305 2 39
7 13 961.7 13215 80 14.89 1083 2 36
8 13 730.9 13241 80 14.88 930 2 34
9 14 0.3 13320 129 14.98 422 2 144

Cycle 103 GMT 2/ 9/2023 8:26: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.2 8 94 14.97 456 2 8
2 6 5404.7 565 167 14.33 3805 2 32
3 3 3475.3 927 15 14.81 2681 2 34
4 7 2917.8 12843 80 14.97 2307 2 38
5 13 1993.9 13059 80 14.90 1746 2 38
6 13 1386.2 13167 80 14.88 1350 2 38
7 13 961.8 13227 80 14.90 1076 2 36
8 13 726.7 13253 80 14.89 922 2 35
9 14 0.4 13332 131 14.98 420 2 146

Cycle 102 GMT 23/ 8/2023 1:36: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.5 8 93 14.98 445 2 7
2 6 5404.1 561 168 14.33 3786 2 33
3 3 3499.3 922 16 14.81 2665 2 34
4 7 2897.1 12843 80 14.97 2301 2 38
5 13 2056.7 13029 80 14.90 1775 2 39
6 13 1222.8 13179 80 14.91 1251 2 38
7 13 967.5 13215 80 14.89 1091 2 36
8 13 736.6 13241 80 14.89 940 2 34
9 14 0.5 13321 129 14.98 428 2 136

Cycle 101 GMT 12/ 8/2023 19: 0: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.7 8 94 14.98 458 2 7
2 6 5407.2 563 167 14.33 3800 2 32
3 3 3426.5 924 12 14.83 2636 2 33
4 7 2939.0 12843 80 14.96 2329 2 38
5 13 2136.7 13023 80 14.90 1831 2 38
6 13 1371.0 13155 80 14.90 1351 2 38
7 13 943.9 13215 80 14.91 1071 2 36
8 13 716.6 13241 80 14.90 925 2 34
9 14 0.6 13319 131 14.99 421 2 115

Cycle 100 GMT 2/ 8/2023 12:21: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.3 8 94 14.98 447 2 7
2 6 5407.6 570 167 14.33 3796 2 32
3 3 3491.9 931 15 14.82 2651 2 33
4 7 2915.6 12843 80 14.97 2295 2 38
5 13 2035.0 13035 80 14.92 1762 2 38
6 13 1207.5 13185 80 14.93 1245 2 38
7 13 991.9 13215 80 14.90 1105 2 37
8 13 731.1 13244 80 14.89 935 2 35
9 14 0.9 13323 129 14.99 428 2 119

Cycle 99 GMT 23/ 7/2023 5:29: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.2 8 94 14.98 449 2 8
2 6 5403.8 579 167 14.34 3794 2 33
3 3 3437.7 941 12 14.84 2630 2 32
4 7 2960.9 12843 80 14.97 2321 2 38
5 13 2079.0 13041 80 14.91 1795 2 38
6 13 1340.7 13173 80 14.91 1324 2 37
7 13 955.2 13227 80 14.91 1077 2 35
8 13 719.3 13253 80 14.90 916 2 34
9 14 0.6 13331 133 14.99 418 2 134

Cycle 98 GMT 12/ 7/2023 22:20: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 94 14.98 453 2 7
2 6 5407.2 552 167 14.34 3791 2 31
3 3 3473.6 914 14 14.83 2647 2 32
4 7 2921.7 12843 80 14.97 2304 2 37
5 13 2020.6 13041 80 14.92 1753 2 37
6 13 1302.5 13167 80 14.92 1298 2 37
7 13 965.4 13215 80 14.91 1081 2 36
8 13 732.4 13241 80 14.90 927 2 34
9 14 1.0 13321 129 14.99 423 2 114

Cycle 97 GMT 2/ 7/2023 15:48: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.7 8 94 14.98 449 2 6
2 6 5407.2 567 167 14.33 3812 2 31
3 3 3491.0 928 15 14.82 2660 2 33
4 7 2917.8 12843 80 14.97 2302 2 37
5 13 1987.2 13053 80 14.93 1741 2 36
6 13 1306.7 13173 80 14.91 1309 2 36
7 13 965.8 13221 80 14.91 1084 2 35
8 13 732.2 13248 80 14.90 933 2 33
9 14 0.6 13326 131 14.99 422 2 122

Cycle 96 GMT 22/ 6/2023 8:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.9 8 94 14.98 452 2 6
2 6 5402.5 550 167 14.34 3797 2 32
3 3 3482.0 911 15 14.82 2648 2 33
4 7 2915.4 12843 80 14.98 2299 2 36
5 13 2054.8 13035 80 14.92 1764 2 37
6 13 1213.4 13185 80 14.93 1246 2 37
7 13 921.5 13227 80 14.92 1056 2 35
8 13 742.9 13248 80 14.90 934 2 34
9 14 0.7 13326 129 14.99 420 2 102

Cycle 95 GMT 12/ 6/2023 2:25: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.6 8 95 14.98 452 2 6
2 6 5406.5 571 167 14.34 3791 2 32
3 3 3451.8 932 13 14.84 2640 2 33
4 7 2901.2 12843 80 14.98 2293 2 38
5 13 1985.7 13053 80 14.93 1731 2 37
6 13 1420.1 13149 80 14.90 1370 2 38
7 13 980.7 13209 80 14.91 1101 2 36
8 13 739.6 13236 80 14.90 936 2 34
9 14 0.9 13315 129 14.99 429 2 115

Cycle 94 GMT 1/ 6/2023 19:43: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 74.1 8 95 14.98 464 2 6
2 6 5366.0 554 167 14.35 3764 2 32
3 3 3474.3 915 15 14.82 2665 2 33
4 7 2889.2 12843 80 14.98 2292 2 37
5 13 1987.0 13047 80 14.92 1746 2 38
6 13 1238.3 13179 80 14.92 1265 2 38
7 13 976.8 13215 80 14.91 1086 2 35
8 13 741.6 13241 80 14.90 936 2 34
9 14 0.7 13321 129 15.00 423 2 121

Cycle 93 GMT 22/ 5/2023 13:11: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.3 8 95 14.99 452 2 6
2 6 5409.4 559 168 14.34 3789 2 32
3 3 3474.1 920 15 14.83 2662 2 33
4 7 2896.1 12843 80 14.98 2293 2 37
5 13 2000.9 13035 80 14.93 1750 2 37
6 13 1356.8 13143 80 14.91 1337 2 37
7 13 996.6 13191 80 14.91 1109 2 36
8 13 735.0 13220 80 14.90 932 2 34
9 14 0.7 13299 131 15.00 423 2 138

Cycle 92 GMT 12/ 5/2023 6:56: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.8 8 96 14.99 455 2 6
2 6 5403.2 577 167 14.34 3812 2 32
3 3 3448.2 938 13 14.83 2651 2 33
4 7 2920.9 12843 80 14.98 2314 2 38
5 13 2000.3 13053 80 14.93 1746 2 37
6 13 1368.3 13161 80 14.91 1338 2 37
7 13 994.8 13215 80 14.91 1097 2 35
8 13 734.3 13244 80 14.91 933 2 34
9 14 1.0 13324 131 15.00 427 2 124

Cycle 91 GMT 1/ 5/2023 23:56: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.9 8 97 14.99 455 2 5
2 6 5403.9 572 167 14.34 3802 2 32
3 3 3450.3 933 13 14.84 2658 2 33
4 7 2898.7 12843 80 14.98 2303 2 37
5 13 1987.5 13053 80 14.93 1745 2 37
6 13 1389.0 13155 80 14.91 1371 2 37
7 13 997.8 13209 80 14.91 1104 2 35
8 13 731.9 13238 80 14.91 932 2 34
9 14 0.9 13317 131 15.00 425 2 133

Cycle 90 GMT 21/ 4/2023 17: 9: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.5 8 97 14.99 450 2 7
2 6 5403.2 571 167 14.34 3823 2 34
3 3 3471.4 932 14 14.83 2684 2 34
4 7 2917.3 12843 80 14.98 2332 2 40
5 13 2127.6 13017 80 14.92 1837 2 39
6 13 1277.7 13161 80 14.93 1300 2 39
7 13 974.0 13203 80 14.92 1094 2 37
8 13 738.4 13229 80 14.91 940 2 36
9 14 1.0 13309 131 15.00 429 2 121

Cycle 89 GMT 11/ 4/2023 10:34: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.9 8 97 14.99 451 2 6
2 6 5404.3 566 168 14.35 3798 2 34
3 3 3433.8 928 12 14.84 2652 2 32
4 7 2927.7 12843 80 14.98 2325 2 39
5 13 2019.8 13047 80 14.93 1771 2 39
6 13 1371.0 13161 80 14.91 1358 2 39
7 13 988.5 13215 80 14.92 1101 2 37
8 13 733.1 13244 80 14.91 936 2 36
9 14 1.3 13324 133 15.00 424 2 117

Cycle 88 GMT 1/ 4/2023 3:44: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.2 8 98 14.99 452 2 7
2 6 5406.2 585 167 14.35 3814 2 33
3 3 3461.9 946 14 14.83 2649 2 33
4 7 2891.7 12843 80 14.98 2298 2 40
5 13 1986.7 13047 80 14.94 1738 2 39
6 13 1349.8 13155 80 14.92 1335 2 40
7 13 964.6 13209 80 14.92 1079 2 38
8 13 717.6 13236 80 14.92 922 2 36
9 14 1.2 13312 131 15.00 429 2 152

Cycle 87 GMT 21/ 3/2023 20:49: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.8 8 99 14.99 462 2 7
2 6 5403.8 572 168 14.34 3790 2 33
3 3 3402.7 934 11 14.85 2641 2 33
4 7 2890.9 12843 80 14.99 2299 2 40
5 13 1983.6 13047 80 14.94 1739 2 40
6 13 1201.3 13185 80 14.95 1249 2 39
7 13 908.8 13227 80 14.94 1052 2 37
8 13 728.4 13248 80 14.91 931 2 36
9 14 0.6 13326 129 15.00 427 2 134

Cycle 86 GMT 11/ 3/2023 13:58: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.1 8 100 14.99 466 2 7
2 6 5406.9 587 168 14.35 3807 2 33
3 3 3422.7 949 12 14.85 2639 2 33
4 7 2880.8 12843 80 14.98 2292 2 40
5 13 1983.1 13053 80 14.94 1741 2 39
6 13 1361.0 13161 80 14.92 1359 2 40
7 13 971.0 13215 80 14.92 1094 2 38
8 13 732.1 13242 80 14.92 932 2 36
9 14 0.8 13321 131 15.01 433 2 156

Cycle 85 GMT 1/ 3/2023 6:56: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.3 8 102 14.99 454 2 6
2 6 5405.2 609 168 14.35 3784 2 32
3 3 3400.1 970 10 14.86 2635 2 32
4 7 2862.5 12843 80 14.99 2287 2 38
5 13 1995.9 13035 80 14.95 1747 2 38
6 13 1215.0 13173 80 14.95 1257 2 38
7 13 964.0 13209 80 14.93 1095 2 36
8 13 737.1 13235 80 14.92 934 2 33
9 14 1.1 13314 129 15.01 441 2 125

Cycle 84 GMT 18/ 2/2023 23:38: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.7 9 105 15.00 447 2 5
2 6 5402.6 625 167 14.35 3803 2 32
3 3 3387.3 986 10 14.86 2636 2 34
4 7 2824.2 12843 80 14.99 2269 2 38
5 13 1989.6 13029 80 14.95 1747 2 38
6 13 1216.9 13161 80 14.95 1266 2 38
7 13 950.3 13197 80 14.93 1077 2 36
8 13 711.8 13224 80 14.92 923 2 34
9 14 1.7 13299 127 15.01 426 2 129

Cycle 83 GMT 8/ 2/2023 16:16: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.1 9 109 15.00 452 2 6
2 6 5402.0 654 167 14.35 3802 2 33
3 3 3354.2 1015 8 14.87 2640 2 34
4 7 2783.0 12843 80 15.00 2244 2 38
5 13 1982.2 13017 80 14.95 1747 2 38
6 13 1268.8 13137 80 14.94 1297 2 38
7 13 968.0 13179 80 14.93 1094 2 36
8 13 722.6 13206 80 14.92 928 2 35
9 14 1.3 13281 125 15.01 422 2 150

Cycle 82 GMT 29/ 1/2023 8:44: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.3 9 114 14.99 458 2 6
2 6 5381.8 745 166 14.37 3788 2 34
3 3 3262.3 0 3 14.93 2648 2 32
4 7 2805.2 13203 80 15.00 2255 2 38
5 13 1973.3 13384 80 14.96 1735 2 38
6 13 1058.6 13544 80 14.99 1168 2 37
7 13 991.2 13554 80 14.93 1103 2 36
8 13 739.1 13581 80 14.92 940 2 35
9 14 0.6 13661 123 15.01 429 2 111

Cycle 81 GMT 18/ 1/2023 23:27: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.1 9 121 14.99 455 2 6
2 6 5183.6 746 166 14.40 3668 2 32
3 7 2669.5 13203 80 15.01 2168 2 38
4 13 1974.8 13344 80 14.97 1730 2 38
5 13 1006.4 13514 80 15.00 1144 2 37
6 13 939.9 13524 80 14.95 1067 2 35
7 13 723.9 13546 80 14.93 927 2 34
8 14 1.8 13621 116 15.01 427 2 148

Cycle 80 GMT 8/ 1/2023 14:47: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.9 9 132 14.99 454 2 6
2 6 4923.3 655 164 14.43 3527 2 33
3 7 2486.2 12843 80 15.04 2072 2 37
4 13 1964.0 12943 80 14.99 1726 2 37
5 13 971.5 13103 80 15.01 1104 2 36
6 13 901.3 13113 80 14.96 1049 2 35
7 13 731.2 13130 80 14.93 930 2 34
8 14 0.7 13205 105 15.01 430 2 148

Cycle 79 GMT 29/12/2022 8:34: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.4 9 115 14.87 416 2 3
2 6 5405.3 497 166 14.57 2808 2 21
3 3 4255.1 859 59 14.66 3145 2 34
4 3 3305.6 0 5 14.96 2609 2 32
5 7 3233.0 12843 80 14.94 2505 2 38
6 13 2316.4 13053 80 14.90 1959 2 38
7 13 1698.5 13163 80 14.88 1563 2 38
8 13 945.4 13273 80 14.95 1087 2 36
9 13 734.9 13298 80 14.93 948 2 33
10 14 0.0 13382 153 15.02 419 2 119

Cycle 78 GMT 19/12/2022 2: 2: 3

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.0 9 123 15.00 448 2 8
2 6 5137.1 744 164 14.41 3669 2 33
3 7 2659.7 13203 80 15.03 2162 2 39
4 13 1963.5 13344 80 14.98 1727 2 39
5 13 1073.1 13494 80 15.00 1165 2 38
6 13 974.2 13506 80 14.94 1093 2 37
7 13 958.1 13508 80 14.87 1074 2 36
8 13 939.1 13510 80 14.80 1046 2 39
9 13 917.4 13512 80 14.75 985 2 246
10 13 893.8 13513 80 14.79 490 246 241
11 13 869.6 13515 80 14.77 478 240 218
12 13 845.3 13517 80 14.75 465 218 212
13 13 821.4 13519 80 14.74 430 212 207
14 13 797.2 13521 80 14.72 411 207 204
15 13 773.0 13523 80 14.70 413 204 205
16 13 743.2 13525 80 14.69 408 204 205
17 14 2.3 13583 1 14.89 421 246 246
18 14 2.3 13585 99 14.86 382 246 246

Cycle 77 GMT 8/12/2022 18: 1: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.0 9 134 14.99 457 2 8
2 6 4928.0 667 164 14.43 3543 2 34
3 7 2463.5 12843 80 15.05 2063 2 39
4 13 1996.0 12933 80 14.99 1749 2 38
5 13 984.3 13092 80 15.01 1114 2 38
6 13 546.4 13151 80 14.98 816 2 33
7 14 0.5 13221 178 15.03 414 2 108

Cycle 76 GMT 28/11/2022 11:18: 3

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.0 9 103 14.88 385 2 2
2 6 5412.7 3 168 14.56 2774 2 19
3 3 5015.0 366 96 14.51 3582 2 35
4 3 3601.1 727 22 14.84 2726 2 34
5 7 3166.4 13570 80 14.96 2463 2 38
6 13 2116.1 13820 80 14.94 1814 2 39
7 13 1575.3 13920 80 14.91 1470 2 38
8 13 994.3 14003 80 14.94 1108 2 37
9 13 77.7 14120 80 15.03 495 2 18
10 14 0.4 14134 146 15.02 428 2 146

Cycle 75 GMT 18/11/2022 5:58: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.5 9 106 14.88 435 2 8
2 6 5402.8 651 168 14.35 3879 2 33
3 3 3325.7 1012 6 14.88 2602 2 33
4 7 2866.6 12843 80 15.01 2269 2 38
5 13 1999.0 13033 80 14.97 1740 2 39
6 13 1184.1 13173 80 14.98 1230 2 38
7 13 969.7 13202 80 14.95 1096 2 37
8 13 954.1 13204 80 14.87 1051 2 36
9 13 935.3 13206 80 14.81 1027 2 36
10 13 913.6 13208 80 14.76 995 2 246
11 13 889.5 13210 80 14.79 539 246 230
12 13 864.6 13212 80 14.78 456 230 202
13 13 839.9 13213 80 14.77 424 201 181
14 13 815.7 13215 80 14.75 405 181 173
15 13 791.5 13217 80 14.74 389 173 173
16 13 767.3 13219 80 14.72 392 173 172
17 13 737.4 13221 80 14.71 382 171 171
18 14 1.3 13279 1 14.89 409 246 246
19 14 1.3 13281 99 14.87 368 246 246

Cycle 74 GMT 7/11/2022 22:34: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.2 9 112 15.01 460 2 8
2 6 5335.8 747 165 14.38 3829 2 32
3 3 3265.3 0 3 14.94 2663 2 32
4 7 2785.0 13203 80 15.02 2231 2 39
5 13 1996.5 13374 80 14.98 1745 2 39
6 13 1138.1 13524 80 14.99 1214 2 38
7 13 999.6 13544 80 14.95 1110 2 37
8 13 959.0 13548 80 14.88 1084 2 36
9 13 940.9 13550 80 14.81 1047 2 36
10 13 919.9 13551 80 14.76 990 2 246
11 13 896.2 13553 80 14.79 523 246 246
12 13 871.4 13555 80 14.78 468 246 219
13 13 846.7 13557 80 14.77 416 218 202
14 13 822.2 13559 80 14.75 426 202 202
15 13 797.8 13561 80 14.74 414 201 200
16 13 773.2 13562 80 14.72 405 201 199
17 13 742.9 13565 80 14.71 388 198 198
18 14 2.1 13623 1 14.90 421 246 246
19 14 2.1 13625 99 14.87 377 246 246

Cycle 73 GMT 28/10/2022 13:48:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.5 9 119 14.88 429 2 8
2 6 5183.7 723 166 14.40 3728 2 32
3 7 2677.2 12843 80 15.03 2185 2 39
4 13 1983.7 12983 80 14.99 1743 2 38
5 13 1193.6 13113 80 14.99 1251 2 38
6 13 988.0 13138 80 14.94 1110 2 37
7 14 -0.6 13261 193 15.03 419 2 121

Cycle 72 GMT 18/10/2022 5:29: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.6 8 100 14.90 400 2 3
2 6 5410.3 476 167 14.55 2859 2 21
3 3 4348.3 838 64 14.64 3190 2 34
4 3 3340.4 0 7 14.95 2610 2 33
5 7 3246.6 12843 80 14.96 2525 2 38
6 13 2325.9 13043 80 14.92 1939 2 38
7 13 1533.8 13183 80 14.92 1452 2 39
8 13 987.2 13263 80 14.95 1110 2 37
9 13 948.6 13268 80 14.89 1089 2 36
10 13 930.7 13269 80 14.82 1054 2 35
11 13 909.6 13271 80 14.76 1032 2 149
12 13 886.1 13273 80 14.76 700 80 246
13 13 860.7 13275 80 14.78 458 246 237
14 13 834.9 13277 80 14.76 443 238 221
15 13 809.3 13279 80 14.74 447 220 214
16 13 783.8 13280 80 14.73 410 214 209
17 13 753.1 13283 80 14.72 395 208 208
18 14 1.6 13341 1 14.90 412 246 246
19 14 1.5 13343 99 14.88 377 246 246

Cycle 71 GMT 7/10/2022 23:54: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.7 9 103 14.90 422 2 7
2 6 5402.7 633 167 14.35 3926 2 33
3 3 3382.6 994 9 14.87 2620 2 34
4 7 2834.9 12843 80 15.02 2257 2 39
5 13 2000.9 13013 80 14.99 1726 2 39
6 13 1173.9 13153 80 15.00 1211 2 38
7 13 972.5 13179 80 14.96 1077 2 37
8 13 956.9 13181 80 14.88 1051 2 36
9 13 937.9 13183 80 14.82 1038 2 36
10 13 916.1 13185 80 14.76 1000 2 246
11 13 892.0 13187 80 14.80 530 246 246
12 13 866.8 13189 80 14.79 452 246 246
13 13 841.5 13190 80 14.78 413 246 242
14 13 816.4 13192 80 14.76 409 242 240
15 13 791.4 13194 80 14.74 399 240 238
16 13 766.2 13196 80 14.73 395 237 238
17 13 735.6 13198 80 14.72 377 237 237
18 14 1.5 13256 1 14.90 399 246 246
19 14 1.5 13258 99 14.88 367 246 246

Cycle 70 GMT 27/ 9/2022 17: 7: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.4 9 106 15.03 444 2 7
2 6 5404.1 649 167 14.35 3921 2 34
3 3 3359.8 1010 8 14.87 2616 2 34
4 7 2854.0 12843 80 15.02 2273 2 39
5 13 1999.4 13023 80 14.98 1742 2 39
6 13 1144.0 13173 80 15.00 1209 2 39
7 13 999.7 13193 80 14.96 1102 2 38
8 13 958.8 13197 80 14.89 1066 2 36
9 13 940.0 13199 80 14.82 1042 2 37
10 13 918.7 13201 80 14.77 998 2 246
11 13 895.1 13203 80 14.80 534 246 246
12 13 870.2 13204 80 14.80 452 246 246
13 13 845.4 13206 80 14.78 421 246 246
14 13 821.0 13208 80 14.76 425 246 241
15 13 796.5 13210 80 14.75 393 240 236
16 13 771.4 13212 80 14.73 390 236 235
17 13 740.4 13214 80 14.72 367 234 234
18 14 1.9 13272 1 14.91 401 246 246
19 14 2.0 13274 99 14.89 366 246 246

Cycle 69 GMT 17/ 9/2022 9:49: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.3 9 110 15.03 433 2 7
2 6 5401.0 750 166 14.37 3895 2 34
3 3 3358.6 0 8 14.89 2603 2 35
4 7 2775.0 13204 80 15.02 2232 2 39
5 13 1965.8 13374 80 14.99 1732 2 39
6 13 1225.1 13504 80 14.99 1256 2 39
7 13 983.3 13536 80 14.96 1096 2 37
8 14 0.1 13662 200 15.06 409 2 118

Cycle 68 GMT 7/ 9/2022 0:25: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.6 9 103 14.91 402 2 3
2 6 5408.8 474 167 14.34 3881 2 33
3 3 3757.9 835 30 14.77 2803 2 35
4 7 3105.3 12843 80 14.99 2417 2 39
5 13 2109.2 13073 80 14.97 1791 2 39
6 13 1347.0 13213 80 14.97 1315 2 39
7 13 984.2 13266 80 14.96 1081 2 37
8 13 77.9 13381 80 15.06 458 2 17
9 14 -0.1 13395 140 15.04 394 2 108

Cycle 67 GMT 27/ 8/2022 18: 1: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 9 105 14.91 419 2 8
2 6 5402.2 631 168 14.35 3916 2 33
3 3 3362.2 993 8 14.87 2597 2 34
4 7 2844.9 12843 80 15.03 2259 2 39
5 13 1976.3 13033 80 15.00 1716 2 39
6 13 1120.9 13183 80 15.02 1182 2 39
7 13 982.8 13203 80 14.97 1083 2 38
8 13 940.9 13207 80 14.90 1055 2 37
9 13 922.1 13209 80 14.84 1019 2 37
10 13 901.0 13211 80 14.78 978 2 246
11 13 877.2 13213 80 14.81 520 246 246
12 13 852.3 13214 80 14.80 448 246 246
13 13 827.6 13216 80 14.79 410 246 246
14 13 803.1 13218 80 14.77 414 246 246
15 13 778.6 13220 80 14.76 396 246 246
16 13 748.1 13222 80 14.74 390 246 246
17 14 1.1 13280 1 14.92 416 246 246
18 14 1.2 13282 99 14.90 368 246 246

Cycle 66 GMT 17/ 8/2022 10:51: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.7 9 110 15.03 418 2 8
2 6 5383.7 755 168 14.37 3898 2 32
3 3 3263.2 0 3 14.96 2621 2 33
4 7 2785.8 13204 80 15.03 2238 2 39
5 13 1999.9 13374 80 15.00 1737 2 39
6 13 1155.7 13514 80 15.01 1203 2 39
7 13 976.4 13536 80 14.97 1076 2 39
8 13 960.5 13538 80 14.90 1056 2 38
9 13 941.6 13540 80 14.83 1038 2 38
10 13 919.9 13542 80 14.78 983 2 246
11 13 895.6 13544 80 14.82 500 246 246
12 13 870.0 13545 80 14.81 449 246 246
13 13 844.2 13547 80 14.79 411 246 246
14 13 818.8 13549 80 14.78 403 246 246
15 13 793.9 13551 80 14.76 390 246 246
16 13 769.2 13553 80 14.75 366 246 246
17 13 739.0 13555 80 14.73 385 246 246
18 14 1.9 13613 1 14.92 413 246 246
19 14 2.0 13615 99 14.89 368 246 246

Cycle 65 GMT 7/ 8/2022 2: 7: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.8 8 92 14.90 381 2 2
2 6 5416.2 577 167 14.31 3936 2 33
3 3 4313.8 1 62 14.63 3203 2 34
4 3 3304.2 362 5 14.98 2594 2 30
5 7 3234.3 13205 80 14.97 2531 2 38
6 13 2236.4 13435 80 14.95 1887 2 39
7 13 1625.0 13545 80 14.93 1496 2 39
8 13 985.9 13638 80 14.97 1087 2 38
9 13 78.2 13755 80 15.06 456 2 19
10 14 0.0 13770 146 15.05 387 2 112

Cycle 64 GMT 27/ 7/2022 20:47: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.5 8 92 14.91 424 2 8
2 6 5406.5 563 167 14.34 3935 2 34
3 3 3496.7 924 16 14.84 2676 2 34
4 7 2914.9 12843 80 15.02 2310 2 39
5 13 1972.3 13053 80 15.00 1713 2 39
6 13 1247.4 13183 80 15.00 1264 2 39
7 13 999.9 13219 80 14.97 1101 2 38
8 13 963.3 13223 80 14.90 1067 2 38
9 13 945.5 13224 80 14.83 1042 2 37
10 13 924.9 13226 80 14.77 1008 2 246
11 13 901.8 13228 80 14.80 550 246 246
12 13 877.3 13230 80 14.80 444 246 246
13 13 852.8 13232 80 14.78 426 246 246
14 13 827.8 13234 80 14.77 424 246 227
15 13 802.4 13235 80 14.75 389 227 227
16 13 776.8 13237 80 14.73 393 227 223
17 13 745.4 13239 80 14.73 365 223 221
18 14 1.1 13298 1 14.90 384 246 246
19 14 1.1 13300 99 14.89 366 246 246

Cycle 63 GMT 17/ 7/2022 14:28: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.8 8 91 15.04 424 2 8
2 6 5404.7 555 168 14.33 3962 2 33
3 3 3469.3 917 14 14.85 2711 2 35
4 7 2939.9 12843 80 15.01 2358 2 39
5 13 2016.5 13043 80 14.99 1773 2 39
6 13 1196.5 13193 80 15.00 1247 2 40
7 13 962.4 13225 80 14.98 1080 2 38
8 13 947.9 13227 80 14.90 1064 2 38
9 13 929.8 13229 80 14.84 1042 2 37
10 13 909.4 13231 80 14.79 1003 2 246
11 13 886.9 13233 80 14.82 535 246 246
12 13 863.5 13235 80 14.81 446 246 246
13 13 839.6 13236 80 14.80 428 246 246
14 13 816.1 13238 80 14.78 412 246 246
15 13 792.2 13240 80 14.77 383 246 246
16 13 768.2 13242 80 14.75 394 246 246
17 13 739.0 13244 80 14.74 368 246 246
18 14 2.0 13302 1 14.93 406 246 246
19 14 2.3 13304 99 14.90 369 246 246

Cycle 62 GMT 7/ 7/2022 8:13: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 8 91 15.04 434 2 9
2 6 5407.4 576 167 14.34 3963 2 33
3 3 3487.6 937 15 14.84 2708 2 35
4 7 2941.5 12843 80 15.01 2356 2 40
5 13 1983.6 13063 80 14.99 1748 2 40
6 13 1296.9 13183 80 14.99 1310 2 40
7 13 987.8 13226 80 14.97 1104 2 39
8 13 32.2 13344 80 15.07 434 2 19
9 14 0.7 13353 125 15.05 395 2 114

Cycle 61 GMT 27/ 6/2022 0:47: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.8 8 91 15.11 439 2 8
2 6 5407.3 592 167 14.34 3951 2 34
3 3 3482.1 953 15 14.84 2704 2 35
4 7 2943.9 12843 80 15.01 2367 2 40
5 13 2097.6 13023 80 14.98 1837 2 40
6 13 1303.9 13163 80 14.99 1311 2 40
7 13 989.5 13206 80 14.97 1100 2 39
8 14 0.1 13332 206 15.07 404 2 126

Cycle 60 GMT 16/ 6/2022 17:29: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.4 8 91 15.11 436 2 8
2 6 5408.7 732 167 14.37 3946 2 34
3 3 3487.2 0 15 14.85 2688 2 35
4 7 2939.6 13203 80 15.02 2352 2 39
5 13 1983.0 13405 80 15.01 1746 2 39
6 13 1352.6 13515 80 15.01 1343 2 40
7 13 993.5 13565 80 15.00 1097 2 39
8 13 28.7 13680 80 15.16 434 2 21
9 14 0.5 13686 125 15.14 402 2 141

Cycle 59 GMT 6/ 6/2022 11: 2: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.7 8 91 15.12 433 2 8
2 6 5406.8 734 167 14.37 3958 2 35
3 3 3480.2 0 15 14.85 2704 2 36
4 7 2929.9 13203 80 15.01 2350 2 40
5 13 2014.2 13405 80 15.01 1761 2 40
6 13 1163.1 13555 80 15.04 1228 2 40
7 13 877.8 13595 80 15.02 1034 2 38
8 13 50.4 13695 80 15.16 447 2 20
9 14 0.5 13704 123 15.14 405 2 112

Cycle 58 GMT 27/ 5/2022 4:15: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.9 8 89 15.10 441 2 7
2 6 5406.5 732 168 14.37 3956 2 35
3 3 3516.2 0 17 14.84 2719 2 36
4 7 2951.7 13203 80 15.01 2357 2 40
5 13 1992.1 13415 80 15.02 1751 2 40
6 13 1306.9 13535 80 15.02 1312 2 40
7 13 946.0 13585 80 15.01 1074 2 38
8 13 55.3 13695 80 15.17 444 2 18
9 14 0.2 13705 125 15.15 398 2 106

Cycle 57 GMT 16/ 5/2022 21:28: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.7 8 90 15.11 433 2 7
2 6 4762.2 577 163 14.48 3542 2 36
3 3 3273.6 938 4 14.96 2612 2 35
4 7 3113.8 12842 80 14.99 2470 2 40
5 13 2139.5 13064 80 14.99 1852 2 40
6 13 1472.3 13184 80 14.99 1425 2 40
7 13 975.5 13254 80 15.01 1096 2 39
8 13 168.6 13354 80 15.14 530 2 21
9 13 14.1 13374 80 15.15 412 2 14
10 14 0.2 13376 58 15.13 392 2 147
11 14 0.4 13377 42 15.12 357 105 246

Cycle 56 GMT 6/ 5/2022 16:44: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 72.0 8 91 15.11 444 2 6
2 6 4106.6 458 160 14.59 3115 2 35
3 7 3128.5 12842 80 14.99 2489 2 40
4 13 2134.3 13074 80 14.99 1853 2 40
5 13 1418.0 13204 80 14.99 1397 2 40
6 13 1000.7 13264 80 15.00 1109 2 39
7 13 204.2 13364 80 15.13 557 2 23
8 14 0.7 13390 140 15.14 397 2 111

Cycle 55 GMT 26/ 4/2022 13:43: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.8 8 93 15.12 440 2 7
2 6 4065.6 452 159 14.60 3094 2 35
3 7 3124.5 12842 80 14.98 2500 2 40
4 13 2189.8 13054 80 14.97 1901 2 40
5 13 1399.2 13194 80 14.99 1382 2 40
6 13 892.5 13264 80 15.02 1043 2 38
7 13 170.0 13354 80 15.14 533 2 22
8 14 0.5 13377 140 15.14 399 2 119

Cycle 54 GMT 16/ 4/2022 11: 2: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.8 8 92 15.12 434 2 7
2 6 5406.5 728 168 14.37 3960 2 35
3 3 3459.1 1089 14 14.86 2689 2 36
4 7 2948.4 12842 80 15.01 2387 2 40
5 13 2023.3 13054 80 15.01 1791 2 40
6 13 1301.6 13184 80 15.02 1319 2 40
7 13 955.2 13234 80 15.02 1086 2 39
8 13 203.5 13324 80 15.14 557 2 23
9 14 0.7 13350 129 15.15 399 2 156

Cycle 53 GMT 6/ 4/2022 4:13: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.8 8 92 15.12 443 2 7
2 6 5404.0 748 167 14.37 3984 2 35
3 3 3479.4 0 15 14.85 2731 2 36
4 7 2945.3 13203 80 15.01 2376 2 40
5 13 2031.8 13405 80 15.01 1790 2 40
6 13 1290.3 13535 80 15.02 1317 2 40
7 13 862.3 13595 80 15.03 1029 2 38
8 13 123.3 13685 80 15.16 486 2 20
9 14 0.6 13702 127 15.15 403 2 148

Cycle 52 GMT 26/ 3/2022 21:12: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.4 8 91 15.13 437 2 7
2 6 5405.3 726 168 14.38 3975 2 35
3 3 3494.9 1087 16 14.85 2732 2 36
4 7 2931.6 12842 80 15.02 2382 2 40
5 13 2004.9 13044 80 15.02 1785 2 40
6 13 1256.2 13174 80 15.03 1297 2 40
7 13 957.6 13214 80 15.02 1088 2 39
8 13 58.7 13324 80 15.18 449 2 18
9 14 0.5 13334 127 15.15 397 2 152

Cycle 51 GMT 16/ 3/2022 14:42: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.9 8 90 15.12 443 2 6
2 6 5407.2 736 168 14.38 3960 2 35
3 3 3486.5 0 15 14.86 2700 2 35
4 7 2976.6 13203 80 15.01 2396 2 40
5 13 1997.7 13425 80 15.02 1781 2 40
6 13 1250.5 13555 80 15.03 1284 2 40
7 13 967.9 13595 80 15.01 1095 2 39
8 13 77.3 13705 80 15.17 456 2 18
9 14 0.3 13717 129 15.16 395 2 129

Cycle 50 GMT 6/ 3/2022 7:38: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.9 8 89 15.12 438 2 7
2 6 5406.6 725 167 14.38 3944 2 35
3 3 3560.1 1086 19 14.84 2740 2 36
4 7 2952.3 12842 80 15.02 2364 2 40
5 13 2013.7 13054 80 15.02 1772 2 40
6 13 1244.1 13194 80 15.04 1284 2 40
7 13 955.3 13234 80 15.02 1089 2 39
8 13 62.2 13344 80 15.17 461 2 19
9 14 0.7 13355 127 15.15 408 2 116

Cycle 49 GMT 24/ 2/2022 0:47: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.2 8 87 15.11 435 2 6
2 6 5407.6 729 167 14.38 3949 2 35
3 3 3520.6 1090 17 14.85 2720 2 36
4 7 3006.9 12842 80 15.02 2397 2 40
5 13 2068.4 13054 80 15.02 1806 2 40
6 13 1433.9 13164 80 15.01 1396 2 40
7 13 943.0 13234 80 15.03 1068 2 39
8 13 129.5 13334 80 15.17 495 2 20
9 13 2.8 13350 80 15.17 398 2 17
10 14 0.6 13352 52 15.15 392 2 155
11 14 0.9 13353 48 15.14 354 116 246

Cycle 48 GMT 13/ 2/2022 17:53: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.3 8 87 15.12 434 2 6
2 6 4196.4 464 161 14.58 3176 2 36
3 7 3203.6 12842 80 14.99 2517 2 40
4 13 2294.5 13044 80 14.98 1930 2 40
5 13 1409.7 13204 80 15.01 1378 2 40
6 13 999.4 13264 80 15.01 1112 2 38
7 13 274.8 13354 80 15.13 605 2 25
8 13 13.8 13385 80 15.16 408 2 14
9 14 0.6 13387 65 15.13 390 2 117
10 14 0.7 13388 35 15.12 361 80 246

Cycle 47 GMT 3/ 2/2022 14:48: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 8 87 15.11 436 2 7
2 6 4413.3 499 161 14.54 3304 2 36
3 3 3232.6 860 1 15.00 2619 2 34
4 7 3209.7 12842 80 14.99 2536 2 40
5 13 2329.1 13044 80 14.97 1969 2 40
6 13 1478.5 13194 80 15.00 1435 2 41
7 13 952.5 13274 80 15.03 1076 2 39
8 13 95.5 13384 80 15.17 481 2 20
9 14 0.6 13398 146 15.15 402 2 139

Cycle 46 GMT 24/ 1/2022 10:58: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.7 8 86 15.12 434 2 8
2 6 4804.5 560 163 14.48 3571 2 36
3 3 3315.5 921 6 14.92 2612 2 35
4 7 3145.5 12842 80 15.00 2498 2 41
5 13 2133.1 13074 80 15.00 1862 2 41
6 13 1370.2 13214 80 15.02 1365 2 41
7 13 964.6 13274 80 15.02 1097 2 39
8 13 162.9 13374 80 15.15 534 2 25
9 13 4.9 13392 80 15.16 414 2 22
10 14 1.4 13394 60 15.14 404 2 140
11 14 1.3 13394 40 15.13 368 101 246

Cycle 45 GMT 14/ 1/2022 6:10: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.4 8 86 15.13 442 2 7
2 6 4186.7 455 160 14.58 3162 2 36
3 7 3233.6 12842 80 14.99 2553 2 40
4 13 2394.2 13024 80 14.96 2015 2 40
5 13 1855.5 13114 80 14.93 1670 2 41
6 13 988.4 13234 80 15.02 1119 2 39
7 13 134.3 13344 80 15.16 511 2 23
8 14 0.7 13361 148 15.15 406 2 124

Cycle 44 GMT 4/ 1/2022 3:42: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.2 8 85 15.12 441 2 8
2 6 4697.9 547 163 14.50 3487 2 36
3 3 3283.4 908 4 14.95 2614 2 35
4 7 3188.5 12842 80 14.99 2517 2 40
5 13 2333.8 13044 80 14.98 1968 2 40
6 13 1556.8 13174 80 14.99 1480 2 41
7 13 992.2 13254 80 15.02 1105 2 39
8 13 53.3 13374 80 15.18 449 2 21
9 14 0.7 13384 144 15.16 404 2 117

Cycle 43 GMT 24/12/2021 23:21: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.9 8 85 15.12 453 2 8
2 6 4432.8 501 161 14.54 3318 2 36
3 3 3239.9 862 2 15.00 2617 2 33
4 7 3203.9 12842 80 15.00 2526 2 40
5 13 2330.8 13034 80 14.98 1965 2 40
6 13 1519.6 13174 80 14.99 1447 2 40
7 13 962.2 13254 80 15.02 1087 2 38
8 13 42.1 13371 80 15.19 443 2 19
9 14 0.5 13378 144 15.16 403 2 110

Cycle 42 GMT 14/12/2021 19:51:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.5 8 85 15.10 438 2 10
2 6 3510.8 365 156 14.68 2712 2 34
3 7 3205.8 12482 80 14.99 2535 2 40
4 13 2335.7 12674 80 14.98 1980 2 40
5 13 1517.0 12814 80 14.99 1455 2 40
6 13 968.7 12894 80 15.02 1100 2 38
7 13 45.8 13012 80 15.18 449 2 20
8 14 0.0 13019 146 15.15 410 2 137

Cycle 41 GMT 4/12/2021 18:36: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.0 8 86 15.11 442 2 9
2 6 3843.1 406 158 14.63 2943 2 35
3 7 3177.2 12842 80 15.00 2519 2 41
4 13 2163.7 13084 80 15.00 1873 2 40
5 13 1492.4 13204 80 15.00 1440 2 40
6 13 1000.9 13274 80 15.01 1118 2 38
7 13 351.9 13354 80 15.10 664 2 31
8 14 0.4 13393 144 15.13 412 2 126

Cycle 40 GMT 24/11/2021 16:25: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.4 8 85 15.12 448 2 10
2 6 4768.6 563 162 14.49 3563 2 36
3 3 3325.4 924 6 14.92 2631 2 35
4 7 3164.6 12842 80 15.00 2517 2 41
5 13 2272.4 13044 80 14.99 1946 2 40
6 13 1480.4 13184 80 15.00 1437 2 40
7 13 988.2 13254 80 15.02 1111 2 38
8 13 335.6 13334 80 15.12 657 2 31
9 14 0.8 13372 142 15.14 412 2 125

Cycle 39 GMT 14/11/2021 12: 0: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.1 8 84 15.12 446 2 11
2 6 4187.7 460 160 14.58 3178 2 35
3 7 3245.4 12843 80 14.99 2567 2 40
4 13 2326.6 13054 80 14.98 1978 2 40
5 13 1475.4 13204 80 15.00 1440 2 40
6 13 996.9 13274 80 15.02 1126 2 38
7 13 120.7 13384 80 15.17 504 2 23
8 14 1.0 13400 146 15.15 412 2 108

Cycle 38 GMT 4/11/2021 8:47: 3

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.9 8 85 15.12 445 2 11
2 6 3572.2 374 156 14.68 2777 2 34
3 7 3209.6 12842 80 15.00 2532 2 40
4 13 2391.7 13024 80 14.97 2012 2 40
5 13 1589.1 13164 80 14.98 1500 2 40
6 13 967.1 13254 80 15.03 1093 2 37
7 13 100.3 13364 80 15.17 489 2 21
8 14 0.5 13378 146 15.15 413 2 108

Cycle 37 GMT 25/10/2021 7:22:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.3 8 85 15.12 441 2 12
2 6 3247.2 329 163 14.72 2541 2 30
3 7 3047.6 12482 80 15.02 2426 2 41
4 13 2040.7 12714 80 15.03 1792 2 40
5 13 1534.2 12804 80 15.00 1465 2 40
6 13 969.9 12884 80 15.02 1096 2 38
7 13 66.5 12994 80 15.17 461 2 21
8 14 0.3 13003 135 15.15 411 2 119

Cycle 36 GMT 15/10/2021 7: 1: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.9 8 85 15.14 438 2 12
2 6 3513.4 363 156 14.70 2724 2 33
3 7 3189.1 12482 80 15.01 2522 2 41
4 13 2335.7 12674 80 14.98 1974 2 40
5 13 1645.7 12794 80 14.98 1536 2 40
6 13 984.6 12884 80 15.02 1103 2 38
7 13 96.2 12994 80 15.18 478 2 21
8 14 0.4 13005 144 15.16 409 2 113

Cycle 35 GMT 5/10/2021 6: 2: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.4 8 86 15.14 443 2 12
2 6 4048.6 441 159 14.61 3075 2 35
3 7 3178.3 12842 80 15.01 2513 2 40
4 13 2248.7 13054 80 15.00 1914 2 40
5 13 1545.3 13184 80 15.01 1464 2 40
6 13 988.9 13264 80 15.04 1101 2 38
7 13 85.5 13374 80 15.19 467 2 21
8 14 0.1 13387 142 15.17 409 2 111

Cycle 34 GMT 25/ 9/2021 3:22:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.3 8 86 15.14 439 2 12
2 6 4568.5 527 162 14.54 3394 2 36
3 3 3234.8 888 1 15.02 2609 2 34
4 7 3192.4 12842 80 15.01 2522 2 41
5 13 2341.5 13024 80 15.00 1966 2 40
6 13 1501.7 13174 80 15.02 1435 2 40
7 13 999.4 13244 80 15.04 1103 2 38
8 13 190.6 13344 80 15.17 549 2 24
9 14 -0.1 13366 142 15.17 411 2 117

Cycle 33 GMT 14/ 9/2021 23:40: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.9 8 84 15.14 444 2 12
2 6 5394.4 702 167 14.39 3943 2 36
3 3 3559.9 1063 19 14.85 2737 2 36
4 7 2972.6 12842 80 15.05 2372 2 41
5 13 1983.4 13064 80 15.06 1737 2 40
6 13 1298.7 13184 80 15.06 1303 2 40
7 13 943.4 13234 80 15.05 1066 2 38
8 14 0.1 13351 206 15.18 405 2 118

Cycle 32 GMT 4/ 9/2021 17:15: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.3 9 102 15.14 443 2 14
2 6 5009.4 666 143 14.49 3685 2 35
3 3 3356.1 1027 8 14.93 2635 2 35
4 7 3087.9 12842 80 15.03 2451 2 40
5 13 2089.4 13074 80 15.03 1816 2 40
6 13 1404.6 13194 80 15.04 1373 2 40
7 13 994.7 13254 80 15.04 1100 2 38
8 13 45.6 13372 80 15.20 445 2 22
9 14 0.4 13379 135 15.17 413 2 115

Cycle 31 GMT 25/ 8/2021 10:56: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.5 8 101 15.15 435 2 14
2 6 5008.1 670 143 14.49 3702 2 36
3 3 3390.4 1031 10 14.92 2645 2 35
4 7 3054.0 12842 80 15.04 2420 2 40
5 13 2184.5 13034 80 15.02 1865 2 40
6 13 1434.2 13164 80 15.03 1401 2 40
7 13 943.4 13234 80 15.06 1071 2 38
8 14 0.1 13351 213 15.19 409 2 106

Cycle 30 GMT 15/ 8/2021 5: 6: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.4 8 101 15.15 430 2 13
2 6 5006.4 667 142 14.50 3686 2 36
3 3 3377.7 1028 9 14.93 2643 2 35
4 7 3091.1 12842 80 15.03 2454 2 40
5 13 2263.8 13024 80 15.01 1910 2 39
6 13 1400.7 13174 80 15.04 1370 2 40
7 13 976.4 13234 80 15.05 1088 2 38
8 14 0.3 13359 215 15.19 403 2 125

Cycle 29 GMT 4/ 8/2021 23: 6: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.4 8 101 15.18 427 2 13
2 6 3796.9 425 136 14.71 2894 2 36
3 7 3199.5 12842 80 15.02 2503 2 40
4 13 2217.1 13074 80 15.02 1869 2 40
5 13 1483.3 13204 80 15.03 1415 2 40
6 13 938.4 13284 80 15.06 1049 2 37
7 13 23.6 13399 80 15.22 418 2 21
8 14 0.1 13405 142 15.18 395 2 126

Cycle 28 GMT 25/ 7/2021 20:27: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.7 8 101 15.19 433 2 13
2 6 3331.3 352 138 14.77 2591 2 34
3 7 3131.0 5042 80 15.04 2467 2 40
4 13 2277.6 5224 80 15.02 1917 2 40
5 13 1469.1 5364 80 15.06 1400 2 40
6 13 966.9 5434 80 15.10 1073 2 37
7 14 0.2 5557 217 15.23 392 2 114

Cycle 27 GMT 20/ 7/2021 23:48: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.4 8 101 15.19 431 2 13
2 6 3294.9 355 140 14.77 2573 2 34
3 7 3083.6 5042 80 15.04 2446 2 40
4 13 2231.2 5234 80 15.04 1886 2 39
5 13 1428.5 5374 80 15.07 1377 2 40
6 13 948.8 5444 80 15.10 1060 2 37
7 14 0.0 5566 215 15.23 399 2 126

Cycle 26 GMT 16/ 7/2021 2:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.0 8 102 15.18 436 2 13
2 6 3755.1 421 136 14.72 2871 2 36
3 7 3157.3 5402 80 15.04 2484 2 40
4 13 2192.5 5624 80 15.04 1867 2 39
5 13 1514.9 5744 80 15.06 1429 2 40
6 13 953.2 5824 80 15.11 1055 2 37
7 13 11.3 5942 80 15.26 411 2 20
8 14 0.1 5946 138 15.22 400 2 115

Cycle 25 GMT 11/ 7/2021 4:41: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.6 8 102 15.19 442 2 12
2 6 4207.9 500 139 14.65 3180 2 37
3 7 3174.4 5402 80 15.04 2510 2 40
4 13 2157.6 5644 80 15.05 1851 2 39
5 13 1588.5 5744 80 15.05 1477 2 40
6 13 967.4 5834 80 15.11 1073 2 37
7 13 164.3 5934 80 15.23 520 2 24
8 14 0.2 5954 142 15.22 404 2 136

Cycle 24 GMT 6/ 7/2021 4:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.5 9 102 15.19 433 2 12
2 6 4940.8 677 142 14.53 3650 2 36
3 3 3357.3 1038 8 14.96 2600 2 36
4 7 3071.7 5402 80 15.06 2442 2 40
5 13 2067.6 5624 80 15.07 1793 2 39
6 13 1397.0 5744 80 15.09 1356 2 40
7 13 969.4 5804 80 15.11 1078 2 37
8 13 7.4 5921 80 15.26 409 2 22
9 14 0.3 5924 131 15.22 400 2 107

Cycle 23 GMT 1/ 7/2021 2:43: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.2 8 101 15.19 437 2 12
2 6 5008.9 663 142 14.52 3707 2 36
3 3 3417.2 1024 11 14.94 2672 2 36
4 7 3071.5 5402 80 15.06 2438 2 40
5 13 2135.8 5614 80 15.06 1831 2 40
6 13 1549.8 5714 80 15.06 1460 2 40
7 13 974.2 5794 80 15.10 1082 2 37
8 14 0.1 5918 215 15.24 397 2 131

Cycle 22 GMT 26/ 6/2021 0:53: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.6 8 100 15.19 428 2 12
2 6 5006.0 660 142 14.52 3706 2 36
3 3 3424.4 1021 12 14.93 2697 2 36
4 7 3034.4 5402 80 15.07 2409 2 40
5 13 2138.0 5604 80 15.06 1836 2 39
6 13 1353.8 5744 80 15.10 1332 2 39
7 13 941.0 5804 80 15.11 1054 2 37
8 14 0.2 5925 213 15.24 401 2 143

Cycle 21 GMT 20/ 6/2021 22:58: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 8 100 15.18 436 2 12
2 6 3828.6 433 137 14.70 2946 2 36
3 7 3174.4 5402 80 15.04 2519 2 40
4 13 2188.4 5634 80 15.05 1866 2 40
5 13 1411.3 5774 80 15.09 1370 2 39
6 13 936.7 5844 80 15.11 1051 2 36
7 14 -0.1 5966 221 15.24 394 2 117

Cycle 20 GMT 16/ 6/2021 0:10: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.2 8 100 15.19 440 2 12
2 6 4093.1 469 137 14.66 3114 2 35
3 3 3224.3 830 1 15.06 2606 2 32
4 7 3217.0 5402 80 15.04 2537 2 40
5 13 2349.6 5604 80 15.02 1983 2 40
6 13 1478.1 5754 80 15.08 1419 2 40
7 13 943.9 5834 80 15.11 1071 2 36
8 13 72.1 5944 80 15.25 464 2 21
9 14 0.1 5954 144 15.22 406 2 116

Cycle 19 GMT 11/ 6/2021 0:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.5 8 100 15.18 430 2 12
2 6 4059.6 462 138 14.67 3084 2 36
3 7 3177.9 5402 80 15.04 2510 2 40
4 13 2243.6 5614 80 15.05 1905 2 39
5 13 1508.8 5744 80 15.08 1431 2 40
6 13 951.1 5824 80 15.11 1069 2 37
7 13 94.5 5934 80 15.25 474 2 22
8 14 0.4 5946 142 15.22 406 2 128

Cycle 18 GMT 6/ 6/2021 1:59: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.4 8 100 15.18 440 2 13
2 6 3653.0 404 136 14.73 2815 2 36
3 7 3208.6 5402 80 15.03 2535 2 40
4 13 2322.6 5594 80 15.03 1949 2 40
5 13 1425.9 5754 80 15.09 1373 2 39
6 13 937.6 5824 80 15.12 1053 2 37
7 13 30.7 5939 80 15.26 423 2 20
8 13 14.2 5941 80 15.24 410 2 24
9 14 0.2 5944 63 15.22 397 2 140
10 14 0.3 5944 37 15.21 364 86 246

Cycle 17 GMT 1/ 6/2021 4: 1: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.7 8 100 15.18 445 2 12
2 6 3362.1 368 137 14.76 2623 2 35
3 7 3187.2 5042 80 15.04 2511 2 40
4 13 2228.9 5264 80 15.05 1901 2 39
5 13 1485.3 5394 80 15.08 1420 2 40
6 13 958.7 5474 80 15.12 1065 2 37
7 13 234.8 5564 80 15.21 574 2 27
8 14 0.2 5591 142 15.22 412 2 117

Cycle 16 GMT 27/ 5/2021 6:31: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.2 8 101 15.18 439 2 12
2 6 3694.8 414 136 14.72 2854 2 35
3 7 3139.9 5402 80 15.05 2499 2 40
4 13 2166.9 5614 80 15.06 1863 2 40
5 13 1462.0 5734 80 15.08 1409 2 40
6 13 965.0 5804 80 15.11 1078 2 37
7 13 82.9 5914 80 15.25 473 2 24
8 14 0.2 5925 140 15.22 413 2 144

Cycle 15 GMT 22/ 5/2021 8:42: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.8 8 101 15.19 442 2 12
2 6 3997.5 461 138 14.68 3047 2 36
3 7 3195.1 5402 80 15.04 2533 2 40
4 13 2263.4 5604 80 15.04 1926 2 39
5 13 1579.9 5724 80 15.07 1482 2 39
6 13 955.4 5814 80 15.12 1073 2 37
7 13 226.8 5904 80 15.22 566 2 28
8 14 0.5 5931 142 15.22 407 2 108

Cycle 14 GMT 17/ 5/2021 9:59: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.2 8 101 15.19 446 2 12
2 6 4548.4 547 140 14.59 3420 2 36
3 3 3231.2 908 1 15.04 2629 2 31
4 7 3205.4 5402 80 15.05 2530 2 39
5 13 2210.6 5624 80 15.06 1885 2 39
6 13 1444.4 5764 80 15.10 1397 2 39
7 13 957.9 5834 80 15.12 1076 2 37
8 13 55.1 5944 80 15.26 447 2 21
9 14 0.0 5952 144 15.23 404 2 128

Cycle 13 GMT 12/ 5/2021 9:29: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.0 9 122 15.19 443 2 13
2 6 4505.8 605 115 14.62 3393 2 36
3 3 3283.3 966 4 15.02 2625 2 34
4 7 3147.1 5402 80 15.05 2509 2 39
5 13 2222.0 5624 80 15.05 1900 2 39
6 13 1438.6 5764 80 15.10 1400 2 39
7 13 954.4 5834 80 15.12 1080 2 37
8 13 66.5 5944 80 15.25 463 2 22
9 14 0.3 5953 140 15.23 413 2 113

Cycle 12 GMT 7/ 5/2021 8: 1: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.4 9 121 15.18 444 2 12
2 6 4509.3 619 115 14.62 3413 2 36
3 3 3271.5 980 3 15.04 2696 2 32
4 7 3186.9 5402 80 15.05 2539 2 40
5 13 2130.5 5654 80 15.07 1848 2 39
6 13 1503.9 5764 80 15.08 1441 2 39
7 13 1000.1 5834 80 15.11 1100 2 36
8 13 20.0 5958 80 15.27 426 2 22
9 14 0.2 5963 140 15.23 406 2 125

Cycle 11 GMT 2/ 5/2021 6: 6: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.8 9 117 15.18 449 2 13
2 6 4508.4 596 114 14.62 3428 2 36
3 3 3318.6 957 6 14.99 2606 2 34
4 7 3198.0 5402 80 15.04 2561 2 39
5 13 2171.9 5644 80 15.06 1890 2 39
6 13 1420.1 5784 80 15.10 1395 2 39
7 13 948.1 5854 80 15.13 1074 2 36
8 13 229.4 5944 80 15.22 580 2 27
9 14 0.6 5971 144 15.22 415 2 135

Cycle 10 GMT 27/ 4/2021 4:29: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.7 9 156 15.18 446 2 14
2 6 3807.9 524 68 14.79 2938 2 34
3 7 3229.6 5403 80 15.03 2566 2 39
4 13 2450.7 5574 80 15.01 2059 2 39
5 13 1482.8 5744 80 15.09 1434 2 39
6 13 963.5 5824 80 15.12 1093 2 36
7 13 85.2 5934 80 15.25 481 2 24
8 14 0.2 5947 146 15.23 416 2 134

Cycle 9 GMT 22/ 4/2021 4:28: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.8 9 145 15.18 451 2 13
2 6 3680.3 482 82 14.79 2863 2 35
3 7 3175.0 4442 80 15.04 2547 2 39
4 13 2309.2 4644 80 15.04 1962 2 39
5 13 1527.0 4784 80 15.08 1460 2 39
6 13 991.4 4864 80 15.12 1103 2 36
7 13 202.1 4964 80 15.23 562 2 27
8 14 0.5 4989 144 15.23 417 2 147

Cycle 8 GMT 17/ 4/2021 21: 7: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.1 9 120 15.17 454 2 13
2 6 3596.0 424 111 14.75 2805 2 35
3 7 3197.5 4442 80 15.04 2560 2 39
4 13 2243.6 4664 80 15.05 1938 2 39
5 13 1483.3 4804 80 15.10 1437 2 39
6 13 998.2 4874 80 15.12 1107 2 36
7 13 108.0 4984 80 15.25 504 2 25
8 14 0.4 4999 144 15.23 422 2 124

Cycle 7 GMT 13/ 4/2021 14:33: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.7 8 95 15.17 457 2 12
2 6 3681.3 404 139 14.70 2871 2 35
3 7 3207.4 722 80 14.99 2563 2 38
4 13 2230.3 944 80 15.04 1922 2 38
5 13 1722.5 1034 80 15.04 1585 2 38
6 13 953.3 1144 80 15.12 1082 2 36
7 13 472.4 1204 80 15.17 755 2 32
8 14 0.7 1257 148 15.21 423 2 131

Cycle 6 GMT 11/ 4/2021 19:39: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.0 8 87 15.15 461 2 12
2 6 4225.7 482 142 14.60 3254 2 35
3 3 3372.8 783 9 14.93 2671 2 36
4 7 3232.6 722 80 14.98 2603 2 38
5 13 2418.3 904 80 15.00 2047 2 38
6 13 1504.1 1064 80 15.08 1460 2 39
7 13 947.7 1144 80 15.12 1084 2 36
8 13 314.4 1224 80 15.20 652 2 29
9 14 0.3 1260 148 15.21 429 2 125

Cycle 5 GMT 9/ 4/2021 23:26: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.0 9 128 15.14 459 2 13
2 6 4013.6 511 85 14.71 3124 2 35
3 3 3560.9 692 3 14.96 2854 2 31
4 7 3430.0 1535 80 14.90 2738 2 37
5 13 2441.7 1757 80 14.97 2083 2 38
6 13 1617.4 1907 80 15.04 1545 2 38
7 13 950.4 2007 80 15.10 1102 2 36
8 13 569.5 2057 80 15.13 842 2 32
9 14 0.4 2122 163 15.19 435 2 138

Cycle 4 GMT 8/ 4/2021 11:56: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.6 9 122 15.22 432 2 12
2 6 4212.0 547 85 14.70 3271 2 35
3 3 3761.4 728 14 14.86 2941 2 36
4 7 3389.8 1571 80 14.90 2731 2 37
5 13 2442.8 1793 80 14.96 2098 2 37
6 13 1682.6 1923 80 15.01 1606 2 38
7 13 961.2 2033 80 15.09 1116 2 36
8 13 336.3 2113 80 15.17 680 2 30
9 14 1.1 2154 161 15.19 435 2 132

Cycle 3 GMT 6/ 4/2021 23:54: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.8 12 311 15.18 432 2 11
2 6 1009.6 185 68 15.11 1067 2 24
3 3 814.6 246 10 15.18 982 2 25
4 7 284.7 550 80 15.31 620 2 24
5 13 250.5 557 80 15.29 582 2 24
6 14 0.5 593 202 15.27 402 2 142

Cycle 2 GMT 6/ 4/2021 13:52: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.9 12 316 15.18 442 2 10
2 6 1006.0 187 69 15.10 1075 2 24
3 3 777.8 248 8 15.17 970 2 24
4 7 252.4 552 80 15.32 588 2 23
5 13 213.3 559 80 15.29 546 2 23
6 13 55.3 579 80 15.29 439 2 21
7 14 0.3 586 120 15.26 397 2 132

Cycle 1 GMT 6/ 4/2021 3:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.4 12 322 15.05 420 2 9
2 6 1009.2 191 68 15.08 1062 2 22
3 3 804.2 252 10 15.15 969 2 23
4 7 187.1 556 80 15.32 540 2 21
5 13 151.5 563 80 15.30 509 2 21
6 14 0.6 585 198 15.27 399 2 121

Cycle 0 GMT 5/ 4/2021 18: 2: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 199.2 41517 445 15.33 517 2 9
2 7 276.4 41519 80 15.23 531 2 9
3 13 262.4 41524 80 15.19 517 2 9
4 13 38.4 41554 80 15.16 390 2 12
5 14 1.4 41561 153 15.13 368 2 123