SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 29 | 15.29 | 383 | 2 | 2 |
2 | 3 | 919.68 | -2 | 15.64 | 1 | 2 | 2 |
3 | 7 | 2009.28 | 30 | 15.13 | 2873 | 2 | 3 |
4 | 13 | 1600.28 | 18 | 15.12 | 2367 | 2 | 3 |
5 | 13 | 1032.32 | 18 | 15.18 | 1674 | 2 | 4 |
6 | 13 | 464.52 | 18 | 15.28 | 934 | 2 | 3 |
7 | 13 | 173.72 | 18 | 15.32 | 501 | 2 | 3 |
8 | 13 | 89.76 | 18 | 15.32 | 368 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.31 | 240 | 2 | 9 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 27 | 15.29 | 379 | 2 | 2 |
2 | 7 | 1512.48 | 30 | 15.23 | 2238 | 2 | 4 |
3 | 13 | 1411.80 | 18 | 15.18 | 2124 | 2 | 4 |
4 | 13 | 844.72 | 18 | 15.23 | 1418 | 2 | 4 |
5 | 13 | 261.40 | 18 | 15.34 | 645 | 2 | 3 |
6 | 13 | 143.80 | 18 | 15.34 | 459 | 2 | 3 |
7 | 13 | 17.80 | 18 | 15.34 | 264 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.31 | 235 | 2 | 8 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 26 | 15.29 | 377 | 2 | 2 |
2 | 3 | 1016.60 | 1 | 15.41 | 1720 | 2 | 2 |
3 | 7 | 1507.04 | 30 | 15.23 | 2247 | 2 | 3 |
4 | 13 | 1413.40 | 18 | 15.20 | 2121 | 2 | 3 |
5 | 13 | 969.60 | 18 | 15.22 | 1575 | 2 | 3 |
6 | 13 | 347.32 | 18 | 15.33 | 765 | 2 | 3 |
7 | 13 | 141.76 | 18 | 15.34 | 451 | 2 | 2 |
8 | 8 | 0.20 | 165 | 15.33 | 233 | 2 | 6 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 31 | 15.30 | 378 | 2 | 2 |
2 | 3 | 805.20 | -4 | 15.64 | 1 | 2 | 2 |
3 | 7 | 1518.04 | 74 | 15.09 | 2239 | 2 | 3 |
4 | 13 | 222.00 | 18 | 15.34 | 580 | 2 | 3 |
5 | 13 | 117.68 | 18 | 15.33 | 416 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.31 | 233 | 2 | 7 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 26 | 15.47 | 349 | 3 | 3 |
2 | 7 | 993.12 | 74 | 15.25 | 1587 | 2 | 3 |
3 | 13 | 48.24 | 18 | 15.38 | 311 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.35 | 240 | 2 | 7 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 169.28 | 26 | 15.58 | 431 | 3 | 3 |
2 | 7 | 181.32 | 74 | 15.56 | 436 | 3 | 3 |
3 | 8 | 0.16 | 240 | 15.51 | 186 | 3 | 8 |