SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 6097 WMO= 5906896


Cycle 99 GMT 12/12/2024 23:20: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.9 8 33 15.01 494 3 14
2 6 5579.6 781 195 14.27 3942 2 40
3 7 2936.5 12002 80 15.00 2392 2 47
4 13 1988.6 12225 80 14.94 1810 2 57
5 13 1360.9 12339 80 14.93 1407 3 59
6 13 989.4 12393 80 14.94 1163 2 48
7 13 729.0 12422 80 14.93 980 2 45
8 14 0.0 12500 103 15.00 453 2 106

Cycle 98 GMT 2/12/2024 11:47: 3

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.5 8 32 15.01 483 2 14
2 6 5603.6 743 193 14.28 3931 2 40
3 3 3063.9 0 3 15.09 2581 2 37
4 7 3016.8 12002 80 14.99 2445 2 48
5 13 2114.5 12219 80 14.92 1884 2 56
6 13 1406.0 12345 80 14.93 1434 3 58
7 13 995.9 12405 80 14.95 1163 2 49
8 13 736.3 12434 80 14.94 986 2 45
9 14 0.0 12514 110 15.00 452 2 114

Cycle 97 GMT 22/11/2024 0:38: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.7 8 32 15.01 497 3 13
2 6 5605.7 755 193 14.27 3951 2 40
3 7 3003.8 12002 80 14.99 2440 2 49
4 13 2158.8 12195 80 14.92 1922 2 56
5 13 1539.1 12303 80 14.91 1519 3 58
6 13 966.4 12387 80 14.96 1145 2 50
7 13 738.8 12413 80 14.94 983 2 44
8 14 0.1 12493 108 15.01 453 2 113

Cycle 96 GMT 11/11/2024 13:37: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.3 8 32 15.01 499 3 15
2 6 5518.4 731 192 14.29 3901 2 42
3 7 3005.8 12002 80 14.99 2441 2 47
4 13 2079.0 12213 80 14.92 1865 2 56
5 13 1520.3 12309 80 14.91 1509 3 58
6 13 978.9 12387 80 14.95 1157 2 50
7 13 734.8 12415 80 14.94 985 2 46
8 14 -0.2 12495 108 15.01 456 2 113

Cycle 95 GMT 1/11/2024 2:58: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 8 32 15.02 493 3 14
2 6 5591.1 789 193 14.28 3939 2 40
3 7 2973.7 12002 80 15.00 2428 2 48
4 13 2011.7 12231 80 14.93 1821 2 57
5 13 1297.9 12363 80 14.95 1363 3 59
6 13 965.1 12411 80 14.96 1135 3 49
7 13 729.9 12437 80 14.94 979 2 45
8 14 0.0 12516 103 15.01 459 3 108

Cycle 94 GMT 21/10/2024 15: 0: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.1 8 33 15.02 499 3 16
2 6 5604.7 782 193 14.27 3958 2 39
3 7 2948.2 12002 80 15.00 2395 2 48
4 13 2156.1 12177 80 14.93 1914 2 56
5 13 1394.2 12309 80 14.94 1422 3 58
6 13 977.9 12369 80 14.96 1148 2 49
7 13 734.1 12395 80 14.95 977 2 45
8 14 0.0 12475 103 15.01 451 2 112

Cycle 93 GMT 11/10/2024 3:49: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.2 8 32 15.02 498 3 15
2 6 5603.3 751 196 14.27 3968 2 40
3 7 2998.5 12002 80 14.99 2428 2 49
4 13 2092.7 12213 80 14.92 1872 2 56
5 13 1412.7 12333 80 14.93 1438 3 58
6 13 994.7 12393 80 14.95 1162 2 50
7 13 720.5 12425 80 14.95 978 2 45
8 14 0.2 12503 105 15.01 457 2 110

Cycle 92 GMT 30/ 9/2024 16:42:58

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.6 8 31 15.02 498 3 14
2 6 5349.9 672 193 14.31 3801 2 39
3 3 3065.8 0 3 15.08 2617 2 37
4 7 3020.5 12002 80 14.98 2449 2 49
5 13 2074.5 12219 80 14.92 1855 2 56
6 13 1474.2 12321 80 14.92 1477 3 58
7 13 973.7 12393 80 14.96 1151 2 50
8 13 746.9 12419 80 14.95 995 2 45
9 14 0.0 12499 108 15.01 452 3 107

Cycle 91 GMT 20/ 9/2024 6:56: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.8 8 30 15.03 496 3 14
2 6 5603.7 753 193 14.28 3943 2 39
3 3 3068.9 0 3 15.10 2557 2 36
4 7 2999.4 12002 80 14.99 2435 2 49
5 13 2122.1 12201 80 14.93 1892 2 56
6 13 1627.7 12285 80 14.90 1577 3 58
7 13 989.8 12375 80 14.96 1164 2 51
8 13 715.5 12407 80 14.96 972 2 45
9 14 -0.1 12484 108 15.02 451 2 112

Cycle 90 GMT 9/ 9/2024 20: 4: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.2 8 32 15.02 504 3 17
2 6 5490.5 755 192 14.29 3891 2 40
3 7 2880.7 12002 80 15.01 2362 2 48
4 13 2032.5 12195 80 14.94 1829 2 57
5 13 1446.2 12297 80 14.94 1455 3 59
6 13 988.1 12363 80 14.96 1155 2 48
7 13 733.6 12392 80 14.95 983 2 44
8 14 -0.2 12470 99 15.02 454 2 100
9 14 -0.2 12470 1 15.00 450 47 95

Cycle 89 GMT 30/ 8/2024 9:27: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.3 8 32 15.02 490 2 16
2 6 5430.6 708 193 14.30 3832 2 39
3 7 2980.9 12002 80 15.00 2412 2 48
4 13 2078.0 12207 80 14.93 1855 2 55
5 13 1626.7 12285 80 14.90 1566 3 57
6 13 992.2 12375 80 14.97 1160 2 50
7 13 718.6 12407 80 14.96 969 2 45
8 14 0.0 12484 110 15.02 454 2 120

Cycle 88 GMT 19/ 8/2024 23:23: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.2 8 31 15.03 494 3 17
2 6 5416.6 701 192 14.31 3827 2 40
3 3 3021.7 0 1 15.07 2586 2 37
4 7 3009.6 12002 80 14.99 2427 2 46
5 13 2051.6 12225 80 14.93 1837 2 54
6 13 1492.3 12327 80 14.93 1475 3 58
7 13 964.0 12405 80 14.97 1137 2 50
8 13 741.2 12431 80 14.96 981 2 44
9 14 0.2 12515 110 15.02 447 2 108

Cycle 87 GMT 9/ 8/2024 12:53: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 8 31 15.02 511 3 15
2 6 5030.1 615 190 14.36 3609 2 40
3 7 2987.3 12002 80 14.99 2424 2 47
4 13 2110.6 12201 80 14.92 1877 2 56
5 13 1487.7 12309 80 14.93 1487 3 58
6 13 985.0 12381 80 14.97 1156 2 50
7 13 733.8 12410 80 14.96 984 2 43
8 14 0.1 12489 108 15.02 457 3 105

Cycle 86 GMT 30/ 7/2024 4:20: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.8 8 32 15.04 498 3 16
2 6 5603.1 788 193 14.29 3953 2 41
3 7 2942.8 12002 80 15.00 2396 2 47
4 13 2051.1 12213 80 14.93 1846 2 56
5 13 1626.8 12285 80 14.91 1569 3 57
6 13 977.3 12375 80 14.97 1159 2 50
7 13 732.4 12403 80 14.96 984 2 44
8 14 0.0 12482 105 15.02 458 2 108

Cycle 85 GMT 19/ 7/2024 16:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.1 8 32 15.03 506 2 15
2 6 5567.1 760 193 14.28 3943 2 41
3 7 2985.5 12002 80 14.99 2421 2 48
4 13 2693.0 12063 80 14.88 2241 2 56
5 13 2683.0 12069 80 14.75 2216 3 57
6 13 2671.0 12075 80 14.63 2193 3 53
7 13 739.6 12281 80 15.00 1003 2 49
8 14 -0.1 12366 118 15.03 460 2 110

Cycle 84 GMT 9/ 7/2024 7:57: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.2 8 32 15.03 497 3 16
2 6 5498.6 735 193 14.30 3897 2 41
3 7 2998.8 12002 80 14.99 2434 2 48
4 13 2073.1 12219 80 14.92 1860 2 57
5 13 1459.9 12333 80 14.94 1469 3 59
6 13 1001.0 12399 80 14.97 1167 2 50
7 13 722.1 12431 80 14.97 980 2 44
8 14 -0.3 12508 108 15.02 468 2 111

Cycle 83 GMT 28/ 6/2024 21: 2: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.9 8 33 15.03 494 3 16
2 6 5603.4 775 193 14.29 3961 2 40
3 7 2941.4 12002 80 14.99 2399 2 47
4 13 2229.1 12159 80 14.92 1949 2 56
5 13 1452.5 12291 80 14.95 1462 3 58
6 13 983.3 12357 80 14.98 1157 2 48
7 13 729.7 12385 80 14.97 978 2 45
8 14 0.2 12465 103 15.03 451 3 114

Cycle 82 GMT 18/ 6/2024 10: 9: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.8 8 34 15.03 497 3 14
2 6 5603.0 791 193 14.29 3940 2 40
3 7 2937.7 12002 80 14.99 2399 2 47
4 13 2078.8 12195 80 14.93 1864 2 56
5 13 1529.4 12291 80 14.94 1508 3 60
6 13 981.3 12369 80 14.98 1159 2 50
7 13 736.2 12398 80 14.97 981 2 46
8 14 0.4 12477 103 15.03 452 2 113

Cycle 81 GMT 7/ 6/2024 22:49: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.8 8 34 15.04 489 2 13
2 6 5603.7 748 193 14.29 3955 2 40
3 7 2992.8 12002 80 14.99 2428 2 48
4 13 2060.6 12219 80 14.93 1843 2 56
5 13 1450.5 12327 80 14.95 1456 3 61
6 13 994.6 12393 80 14.98 1156 2 50
7 13 732.7 12422 80 14.97 973 2 45
8 14 -0.3 12502 105 15.03 453 3 102

Cycle 80 GMT 28/ 5/2024 11:48: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.7 8 35 15.04 498 3 14
2 6 5603.1 777 193 14.29 3967 2 41
3 7 2949.6 12002 80 14.99 2394 2 46
4 13 2044.5 12213 80 14.93 1833 2 57
5 13 1355.6 12333 80 14.97 1397 3 59
6 13 980.9 12387 80 14.98 1149 2 48
7 13 744.2 12413 80 14.97 987 2 45
8 14 -0.1 12493 103 15.03 452 2 115

Cycle 79 GMT 18/ 5/2024 0:24: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.6 8 36 15.04 493 3 12
2 6 5603.6 782 193 14.29 3968 2 42
3 7 2959.2 12002 80 14.99 2402 2 47
4 13 2071.0 12207 80 14.93 1859 2 56
5 13 1353.6 12333 80 14.97 1394 3 60
6 13 978.7 12387 80 14.98 1154 2 49
7 13 731.7 12415 80 14.97 981 2 44
8 14 0.2 12495 103 15.03 454 2 108

Cycle 78 GMT 7/ 5/2024 12:53: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.0 6 37 15.04 477 3 12
2 6 5602.6 786 193 14.28 4021 2 42
3 7 2906.0 12002 80 14.99 2373 2 48
4 13 1992.6 12219 80 14.94 1805 2 56
5 13 1447.7 12315 80 14.95 1455 3 60
6 13 987.2 12381 80 14.99 1153 2 50
7 13 732.0 12409 80 14.98 975 2 45
8 14 -0.1 12489 101 15.03 457 2 102

Cycle 77 GMT 27/ 4/2024 1:25: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.1 8 37 15.05 487 3 11
2 6 5603.4 759 193 14.29 3953 2 41
3 7 2991.6 12002 80 14.98 2423 2 48
4 13 2029.5 12225 80 14.93 1828 2 56
5 13 1535.2 12315 80 14.94 1509 3 59
6 13 988.3 12393 80 14.99 1154 3 50
7 13 735.2 12422 80 14.98 981 2 45
8 14 0.0 12505 110 15.03 451 3 107

Cycle 76 GMT 16/ 4/2024 14: 8: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.5 8 38 15.04 493 3 11
2 6 5603.3 789 194 14.30 3954 2 39
3 7 2912.6 12002 80 15.00 2367 2 48
4 13 1986.0 12213 80 14.95 1796 2 56
5 13 1333.4 12333 80 14.98 1381 3 57
6 13 1000.1 12381 80 14.99 1155 2 48
7 13 721.3 12413 80 14.98 961 2 46
8 14 0.1 12490 101 15.04 447 2 104

Cycle 75 GMT 6/ 4/2024 2:38: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.1 8 38 15.04 486 3 10
2 6 5603.5 769 193 14.30 3941 2 41
3 7 3014.0 12002 80 14.98 2423 2 47
4 13 2077.2 12225 80 14.93 1851 2 56
5 13 1529.7 12321 80 14.95 1505 3 59
6 13 991.1 12399 80 15.00 1148 2 50
7 13 732.5 12428 80 14.99 973 2 45
8 14 0.0 12508 112 15.04 443 2 108

Cycle 74 GMT 26/ 3/2024 15: 9: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.9 8 37 15.05 484 3 11
2 6 5602.8 747 196 14.29 3954 2 42
3 7 3008.9 12002 80 14.98 2434 2 48
4 13 2099.0 12213 80 14.93 1867 2 56
5 13 1428.5 12333 80 14.97 1442 3 59
6 13 978.7 12399 80 15.00 1148 2 48
7 13 752.8 12425 80 14.98 989 2 44
8 14 0.1 12510 112 15.03 454 2 110

Cycle 73 GMT 16/ 3/2024 3:56: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.6 8 37 15.05 489 3 11
2 6 5603.3 756 193 14.29 3976 2 40
3 3 3029.3 0 1 15.09 2580 2 37
4 7 3013.0 12002 80 14.99 2422 2 47
5 13 2117.7 12213 80 14.93 1874 2 55
6 13 1471.9 12327 80 14.96 1473 3 59
7 13 976.7 12399 80 15.00 1147 2 49
8 13 732.7 12427 80 14.99 982 2 44
9 14 -0.1 12507 112 15.04 452 2 107

Cycle 72 GMT 5/ 3/2024 16:41: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 73.2 8 39 15.05 491 3 13
2 6 5602.1 814 196 14.30 3965 2 41
3 7 2807.7 12002 80 15.01 2310 2 48
4 13 1997.3 12183 80 14.95 1808 2 56
5 13 1360.9 12291 80 14.98 1402 3 57
6 13 972.5 12345 80 15.00 1148 3 47
7 13 733.0 12371 80 14.98 979 2 45
8 14 0.2 12450 99 15.04 450 2 109
9 14 0.3 12450 1 15.03 440 55 96

Cycle 71 GMT 24/ 2/2024 5:25: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 38 15.05 490 3 12
2 6 5603.7 742 194 14.29 3987 2 42
3 3 3033.7 0 1 15.07 2595 2 35
4 7 3030.8 12002 80 14.99 2447 2 47
5 13 2081.6 12219 80 14.93 1860 2 54
6 13 1483.5 12327 80 14.96 1483 3 59
7 13 982.4 12399 80 15.00 1153 2 49
8 13 734.3 12428 80 14.99 985 2 45
9 14 0.0 12509 112 15.04 448 2 116

Cycle 70 GMT 13/ 2/2024 18:23: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.2 8 38 15.05 498 3 11
2 6 5592.4 758 193 14.29 3977 2 42
3 7 3008.1 12002 80 14.98 2430 2 46
4 13 2201.9 12183 80 14.93 1937 2 56
5 13 1478.1 12309 80 14.97 1479 3 59
6 13 969.4 12381 80 15.01 1151 2 50
7 13 743.9 12407 80 14.99 989 2 44
8 14 -0.1 12486 110 15.04 452 2 104

Cycle 69 GMT 3/ 2/2024 7:24: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.1 8 38 15.05 495 3 12
2 6 5603.2 758 193 14.29 3984 2 41
3 7 3017.7 12002 80 14.99 2445 2 47
4 13 2054.4 12231 80 14.94 1858 2 56
5 13 1461.8 12339 80 14.97 1482 3 58
6 13 965.0 12411 80 15.01 1150 2 50
7 13 741.1 12437 80 14.99 994 2 44
8 14 0.1 12520 108 15.04 459 2 106

Cycle 68 GMT 23/ 1/2024 19:53: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.1 8 38 15.05 500 3 12
2 6 5603.0 765 194 14.30 3973 2 40
3 7 2964.3 12002 80 14.99 2415 2 47
4 13 2049.5 12219 80 14.95 1842 2 56
5 13 1273.8 12357 80 15.01 1352 3 56
6 13 979.5 12399 80 15.00 1150 3 48
7 13 746.4 12425 80 14.99 983 2 46
8 14 0.1 12504 105 15.04 459 2 108

Cycle 67 GMT 13/ 1/2024 8:33: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.7 8 39 15.06 492 3 12
2 6 5605.3 773 193 14.30 3959 2 42
3 7 2961.7 12002 80 15.00 2415 2 48
4 13 2110.5 12189 80 14.94 1891 2 56
5 13 1453.5 12303 80 14.97 1466 3 58
6 13 993.0 12369 80 15.01 1163 2 49
7 13 737.5 12399 80 14.99 991 2 45
8 14 0.0 12478 105 15.04 459 3 107

Cycle 66 GMT 2/ 1/2024 21:26: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.6 8 39 15.05 494 3 13
2 6 5605.8 756 195 14.29 3960 2 42
3 7 2962.6 12002 80 15.00 2416 2 48
4 13 2032.0 12219 80 14.95 1840 2 57
5 13 1423.5 12327 80 14.98 1448 3 58
6 13 998.1 12387 80 15.00 1167 2 50
7 13 712.8 12419 80 15.00 971 2 45
8 14 0.0 12495 105 15.05 448 3 114

Cycle 65 GMT 23/12/2023 10:22:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.0 8 37 15.06 498 3 11
2 6 5606.3 743 194 14.29 3978 2 42
3 3 3074.0 0 3 15.07 2642 2 38
4 7 3024.9 12002 80 14.99 2460 2 48
5 13 2166.1 12195 80 14.94 1925 2 56
6 13 1512.4 12309 80 14.97 1509 3 58
7 13 968.7 12387 80 15.02 1152 2 50
8 13 739.7 12413 80 15.00 991 2 45
9 14 0.1 12493 110 15.05 451 2 117

Cycle 64 GMT 12/12/2023 23:31: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.1 8 38 15.05 502 3 14
2 6 5603.0 772 193 14.30 3972 2 41
3 7 2959.9 12002 80 15.00 2418 2 48
4 13 2005.1 12225 80 14.96 1828 2 56
5 13 1258.3 12363 80 15.02 1351 3 56
6 13 973.4 12405 80 15.01 1159 3 47
7 13 740.6 12431 80 14.99 992 2 45
8 14 0.1 12510 103 15.05 464 2 106

Cycle 63 GMT 2/12/2023 11:55: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.4 8 38 15.06 510 2 15
2 6 5603.4 766 195 14.28 4000 2 42
3 7 2991.4 12002 80 15.00 2451 2 48
4 13 2070.4 12219 80 14.95 1874 2 56
5 13 1308.8 12357 80 15.01 1385 3 56
6 13 979.1 12405 80 15.01 1160 3 47
7 13 732.6 12433 80 15.00 994 2 44
8 14 0.0 12512 105 15.05 459 2 103

Cycle 62 GMT 22/11/2023 0:26: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.4 8 37 15.06 509 3 15
2 6 5603.6 757 194 14.29 3998 2 41
3 3 3024.5 0 1 15.08 2594 2 38
4 7 3008.0 12002 80 14.99 2456 2 47
5 13 2098.7 12207 80 14.95 1885 2 56
6 13 1405.5 12333 80 14.99 1455 3 58
7 13 994.6 12393 80 15.01 1179 2 50
8 13 737.2 12423 80 15.00 992 2 44
9 14 0.3 12503 108 15.05 469 2 109

Cycle 61 GMT 11/11/2023 13:14: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.1 8 37 15.06 505 3 15
2 6 5606.0 754 193 14.30 3986 2 42
3 7 3006.3 12002 80 15.00 2439 2 47
4 13 2098.9 12213 80 14.96 1880 2 56
5 13 1441.2 12333 80 14.99 1457 3 57
6 13 983.1 12399 80 15.02 1161 2 49
7 13 736.4 12428 80 15.01 995 2 44
8 14 -0.2 12508 110 15.06 461 3 115

Cycle 60 GMT 1/11/2023 1:52:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.2 8 37 15.07 502 3 15
2 6 5605.4 770 193 14.30 3944 2 41
3 7 3004.8 12002 80 15.00 2446 2 47
4 13 2105.2 12207 80 14.96 1883 2 55
5 13 1454.9 12321 80 14.99 1475 3 57
6 13 961.8 12393 80 15.02 1151 2 50
7 13 735.6 12419 80 15.01 997 2 45
8 14 0.2 12499 110 15.06 468 3 113

Cycle 59 GMT 21/10/2023 14:31: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 8 36 15.07 505 3 17
2 6 5578.2 736 195 14.29 3983 2 42
3 7 3022.3 12002 80 15.00 2453 2 47
4 13 2081.5 12225 80 14.97 1869 2 55
5 13 1425.1 12345 80 15.00 1461 3 58
6 13 977.9 12411 80 15.03 1157 2 49
7 13 744.8 12437 80 15.01 996 2 44
8 14 0.2 12517 108 15.06 456 3 106

Cycle 58 GMT 11/10/2023 3:26: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.4 8 35 15.07 511 3 17
2 6 5606.0 736 195 14.29 3968 2 41
3 3 3045.0 0 2 15.08 2628 2 38
4 7 3009.9 12002 80 15.00 2455 2 47
5 13 2073.0 12219 80 14.96 1873 2 55
6 13 1459.7 12327 80 14.99 1483 3 58
7 13 977.0 12399 80 15.03 1166 3 50
8 13 735.5 12428 80 15.01 1001 2 44
9 14 -0.2 12508 108 15.06 462 3 108

Cycle 57 GMT 30/ 9/2023 16:29: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.4 8 34 15.06 509 3 16
2 6 5576.3 733 195 14.29 3970 2 41
3 3 3019.4 0 1 15.08 2596 2 39
4 7 2997.3 12002 80 15.01 2447 2 48
5 13 2042.3 12225 80 14.97 1854 2 55
6 13 1356.4 12351 80 15.01 1415 3 56
7 13 997.2 12405 80 15.02 1174 2 49
8 13 716.3 12437 80 15.02 989 2 43
9 14 0.1 12514 105 15.07 466 3 110

Cycle 56 GMT 20/ 9/2023 5:33: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.7 8 33 15.07 516 3 16
2 6 5600.9 752 193 14.30 3953 2 41
3 3 3052.9 0 2 15.07 2598 2 38
4 7 3020.1 12002 80 15.00 2463 2 47
5 13 2067.1 12225 80 14.97 1872 2 56
6 13 1482.6 12327 80 14.99 1492 3 57
7 13 983.7 12399 80 15.03 1164 3 51
8 13 739.0 12428 80 15.01 988 2 44
9 14 0.0 12508 108 15.06 465 2 105

Cycle 55 GMT 9/ 9/2023 18:21: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.5 8 33 15.07 506 2 17
2 6 5566.0 753 193 14.31 3944 2 41
3 7 3018.5 12002 80 15.01 2456 2 46
4 13 2203.3 12189 80 14.96 1955 2 56
5 13 1573.4 12297 80 14.98 1555 3 58
6 13 994.8 12381 80 15.03 1176 3 51
7 13 723.3 12413 80 15.02 987 2 43
8 14 0.2 12493 110 15.07 475 3 112

Cycle 54 GMT 30/ 8/2023 7:21: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.4 8 35 15.05 509 2 18
2 6 5461.4 751 193 14.32 3903 2 42
3 7 2819.2 12002 80 15.03 2329 2 49
4 13 1999.4 12189 80 14.99 1822 2 57
5 13 1262.8 12321 80 15.04 1351 2 55
6 13 964.8 12363 80 15.03 1145 3 47
7 13 726.1 12389 80 15.02 982 2 43
8 14 -0.3 12466 95 15.07 456 2 110
9 14 -0.3 12466 5 15.07 453 57 123

Cycle 53 GMT 19/ 8/2023 20:53: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.5 8 36 15.07 515 2 17
2 6 5489.8 731 192 14.32 3888 2 42
3 7 2970.6 12002 80 15.02 2427 2 47
4 13 2095.5 12201 80 14.98 1879 2 56
5 13 1451.5 12315 80 15.00 1482 3 56
6 13 993.7 12381 80 15.03 1165 2 49
7 13 734.6 12410 80 15.02 988 2 44
8 13 23.8 12485 80 15.06 475 2 54
9 14 0.0 12491 24 15.07 457 9 112
10 14 0.0 12492 76 15.05 424 43 247

Cycle 52 GMT 9/ 8/2023 10:17: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.1 8 37 15.07 501 2 17
2 6 5452.5 729 194 14.33 3868 2 41
3 7 2908.0 12002 80 15.02 2399 2 48
4 13 2007.9 12213 80 14.99 1835 2 56
5 13 1360.6 12327 80 15.02 1429 3 56
6 13 977.6 12381 80 15.03 1163 2 47
7 13 747.1 12407 80 15.02 1002 2 44
8 14 -0.1 12486 101 15.07 473 2 107

Cycle 51 GMT 29/ 7/2023 23:49: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.0 8 36 15.08 517 3 17
2 6 5579.9 747 193 14.31 3950 2 41
3 3 3034.8 0 1 15.09 2610 2 37
4 7 3006.0 12002 80 15.01 2449 2 48
5 13 2049.1 12231 80 14.99 1851 2 55
6 13 1386.1 12351 80 15.02 1438 3 56
7 13 967.6 12411 80 15.04 1160 2 49
8 13 738.2 12437 80 15.02 1003 2 44
9 14 0.3 12517 108 15.07 462 2 109

Cycle 50 GMT 19/ 7/2023 12:31: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.2 8 36 15.08 529 3 17
2 6 5427.1 710 193 14.33 3881 2 41
3 7 2960.4 12002 80 15.02 2433 2 48
4 13 2065.0 12207 80 14.99 1870 2 55
5 13 1509.3 12303 80 15.00 1519 3 56
6 13 1000.3 12375 80 15.04 1180 2 49
7 13 723.8 12407 80 15.03 990 2 43
8 14 -0.3 12484 105 15.08 471 3 119

Cycle 49 GMT 9/ 7/2023 2:25: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.2 8 38 15.08 513 3 17
2 6 5603.1 783 193 14.31 3966 2 42
3 7 2924.7 12002 80 15.03 2417 2 48
4 13 2006.7 12213 80 15.00 1834 2 56
5 13 1469.5 12309 80 15.01 1498 3 56
6 13 973.8 12381 80 15.04 1163 2 48
7 13 745.4 12407 80 15.03 1005 2 43
8 14 -0.1 12487 101 15.08 463 2 104

Cycle 48 GMT 28/ 6/2023 14:59: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.2 8 39 15.08 515 3 17
2 6 5602.6 791 196 14.31 3973 2 41
3 7 2848.1 12002 80 15.04 2367 2 49
4 13 1984.5 12201 80 15.01 1813 2 56
5 13 1307.1 12321 80 15.04 1386 2 55
6 13 972.6 12369 80 15.04 1158 2 46
7 13 740.8 12395 80 15.03 1003 2 44
8 14 0.5 12475 97 15.08 477 2 103
9 14 0.4 12475 3 15.07 478 42 92

Cycle 47 GMT 18/ 6/2023 3:37: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.8 8 38 15.08 539 3 16
2 6 5560.8 734 193 14.31 3976 2 41
3 3 3066.6 0 3 15.07 2646 2 37
4 3 3019.7 601 1 15.18 2617 2 38
5 7 3007.3 12002 80 15.02 2458 2 48
6 13 2097.0 12201 80 14.99 1890 2 55
7 13 1536.0 12297 80 15.00 1542 3 56
8 13 986.5 12375 80 15.05 1175 2 49
9 13 734.5 12404 80 15.03 1006 2 43
10 14 -0.1 12484 112 15.08 472 2 116

Cycle 46 GMT 7/ 6/2023 17: 7: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.9 8 39 15.08 515 3 17
2 6 5530.6 748 194 14.32 3928 2 42
3 7 2913.2 12002 80 15.04 2398 2 48
4 13 2045.2 12195 80 15.00 1863 2 56
5 13 1425.6 12303 80 15.02 1473 2 55
6 13 965.9 12369 80 15.05 1167 2 48
7 13 732.2 12395 80 15.03 1006 2 44
8 14 -0.2 12473 103 15.07 512 2 115

Cycle 45 GMT 28/ 5/2023 6:31: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.3 8 38 15.08 530 3 16
2 6 5493.9 705 192 14.32 3927 2 41
3 3 3061.3 0 3 15.09 2592 2 37
4 7 3021.7 12002 80 15.02 2486 2 47
5 13 2091.3 12213 80 15.00 1900 2 55
6 13 1516.8 12315 80 15.01 1542 3 56
7 13 966.5 12393 80 15.05 1175 2 49
8 13 743.3 12419 80 15.03 1018 2 43
9 14 0.2 12499 110 15.08 473 2 112

Cycle 44 GMT 17/ 5/2023 20:14: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.8 8 41 15.08 540 2 16
2 6 5263.6 699 191 14.36 3781 2 42
3 7 2783.0 12002 80 15.06 2337 2 49
4 13 1983.6 12177 80 15.01 1830 2 56
5 13 1375.1 12279 80 15.03 1444 2 55
6 13 983.6 12333 80 15.05 1176 2 47
7 13 743.5 12359 80 15.03 1009 2 44
8 14 -0.4 12438 95 15.08 482 2 111
9 14 -0.2 12438 5 15.08 465 50 130

Cycle 43 GMT 7/ 5/2023 11: 1: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.6 8 42 15.09 518 2 14
2 6 5243.1 679 190 14.37 3764 2 43
3 7 2940.3 12002 80 15.04 2421 2 48
4 13 1998.9 12225 80 15.01 1841 2 55
5 13 1517.7 12309 80 15.01 1539 2 56
6 13 963.0 12387 80 15.05 1173 2 48
7 13 727.2 12413 80 15.03 1011 2 43
8 14 0.5 12492 103 15.08 506 2 103

Cycle 42 GMT 27/ 4/2023 1:15: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.9 8 41 15.09 541 3 14
2 6 5257.8 658 192 14.37 3768 2 45
3 7 3000.9 12002 80 15.04 2453 2 48
4 13 2153.5 12195 80 14.99 1928 2 55
5 13 1441.9 12321 80 15.03 1482 2 55
6 13 981.7 12387 80 15.06 1175 2 48
7 13 731.6 12416 80 15.04 1001 2 42
8 14 -0.1 12494 110 15.09 470 2 108

Cycle 41 GMT 16/ 4/2023 15:52: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.5 8 42 15.09 544 3 14
2 6 4951.5 583 189 14.42 3578 2 44
3 7 2973.5 12002 80 15.04 2450 2 48
4 13 2026.2 12225 80 15.02 1861 2 55
5 13 1448.1 12327 80 15.03 1493 2 55
6 13 983.0 12393 80 15.06 1186 2 48
7 13 734.1 12422 80 15.04 1010 2 42
8 14 -0.1 12500 108 15.09 481 3 105

Cycle 40 GMT 6/ 4/2023 7:36: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.4 8 42 15.10 530 3 13
2 6 5457.6 707 192 14.33 3950 2 44
3 7 2996.4 12002 80 15.05 2469 2 48
4 13 2104.6 12207 80 15.01 1911 2 55
5 13 1393.4 12333 80 15.05 1451 2 54
6 13 980.5 12393 80 15.07 1172 2 48
7 13 734.2 12421 80 15.05 1006 2 42
8 14 -0.1 12500 108 15.09 507 2 105

Cycle 39 GMT 26/ 3/2023 21:16: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.9 8 43 15.10 554 3 13
2 6 5481.3 734 192 14.35 3907 2 45
3 7 2945.4 12002 80 15.06 2436 2 48
4 13 2026.2 12213 80 15.03 1863 2 55
5 13 1394.1 12327 80 15.05 1451 2 55
6 13 988.8 12387 80 15.07 1185 2 48
7 13 733.4 12416 80 15.05 1014 2 42
8 14 0.1 12495 106 15.10 479 3 120

Cycle 38 GMT 16/ 3/2023 10:36: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 45 15.04 547 2 14
2 6 5403.3 731 192 14.35 3862 2 46
3 7 2848.9 12002 80 15.08 2378 2 48
4 13 1991.9 12195 80 15.04 1850 2 55
5 13 1371.7 12303 80 15.06 1456 2 55
6 13 991.0 12357 80 15.07 1193 2 47
7 13 730.8 12386 80 15.06 1023 2 43
8 14 0.0 12463 101 15.10 517 2 113

Cycle 37 GMT 6/ 3/2023 0:28: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.0 9 48 15.04 528 3 17
2 6 5439.4 721 63 14.58 3948 2 40
3 7 4882.6 12243 80 14.81 3610 2 46
4 13 3917.0 12471 80 14.76 3018 2 49
5 13 2736.4 12719 80 14.86 2311 2 50
6 13 1874.7 12879 80 14.94 1757 2 54
7 13 993.0 13027 80 15.05 1185 2 49
8 13 965.2 13031 80 14.98 1150 3 44
9 13 714.5 13058 80 14.98 995 2 46
10 14 0.1 13130 73 15.04 510 2 111
11 14 0.3 13131 27 15.03 468 55 247

Cycle 36 GMT 24/ 2/2023 1:25: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.1 9 53 15.05 534 3 18
2 6 5408.1 729 63 14.59 3921 2 40
3 7 4769.6 12243 80 14.84 3546 2 47
4 13 3882.3 12443 80 14.78 2992 2 48
5 13 2592.3 12715 80 14.90 2208 2 50
6 13 1921.3 12835 80 14.93 1789 2 55
7 13 990.8 12983 80 15.05 1203 2 50
8 13 963.9 12987 80 14.98 1167 3 44
9 13 728.0 13012 80 14.98 1013 2 49
10 14 0.0 13083 65 15.05 518 3 108
11 14 0.1 13084 35 15.03 486 51 247

Cycle 35 GMT 14/ 2/2023 3: 0: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.7 9 58 15.08 504 3 18
2 6 5378.6 702 62 14.60 3870 2 41
3 7 4830.9 12243 80 14.84 3554 2 46
4 13 3889.7 12471 80 14.79 2982 2 48
5 13 2766.6 12699 80 14.88 2302 2 50
6 13 1835.3 12863 80 14.96 1720 2 55
7 13 1024.3 12995 80 15.05 1205 2 49
8 13 999.2 12999 80 14.99 1173 3 44
9 13 732.2 13026 80 14.98 1003 2 48
10 14 0.0 13098 67 15.06 496 3 100
11 14 0.1 13099 33 15.04 466 49 247

Cycle 34 GMT 4/ 2/2023 4:43: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.7 9 58 15.05 533 2 18
2 6 5241.2 701 65 14.61 3802 2 41
3 7 4702.9 12243 80 14.86 3481 2 47
4 13 3906.4 12415 80 14.80 2990 2 49
5 13 2516.7 12711 80 14.93 2141 2 50
6 13 1808.0 12835 80 14.97 1697 2 55
7 13 987.1 12963 80 15.06 1166 2 50
8 13 743.4 12994 80 15.05 1000 2 42
9 14 0.1 13079 135 15.09 456 2 109

Cycle 33 GMT 25/ 1/2023 6:51: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.1 9 58 15.09 519 3 20
2 6 5299.9 728 62 14.62 3859 2 41
3 7 4667.9 12243 80 14.87 3460 2 47
4 13 3737.2 12455 80 14.82 2900 2 49
5 13 2469.3 12723 80 14.94 2119 2 51
6 13 1797.0 12843 80 14.97 1696 2 55
7 13 983.3 12967 80 15.06 1179 2 49
8 13 955.3 12971 80 15.00 1138 3 44
9 13 732.9 12994 80 14.99 989 2 53
10 14 0.0 13064 54 15.07 503 3 105
11 14 -0.1 13065 46 15.05 463 49 247

Cycle 32 GMT 15/ 1/2023 8:46: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 9 69 15.08 498 3 22
2 6 5365.8 903 63 14.63 3932 2 41
3 7 4360.9 12484 80 14.92 3296 2 47
4 13 3379.7 12712 80 14.88 2664 2 49
5 13 2219.9 12964 80 14.98 1958 2 53
6 13 1563.4 13080 80 15.02 1552 2 55
7 13 982.8 13164 80 15.07 1168 2 48
8 13 718.2 13194 80 15.06 984 2 42
9 14 -0.2 13273 114 15.10 465 3 110

Cycle 31 GMT 5/ 1/2023 8:17: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.3 9 61 15.09 496 3 18
2 6 5458.8 643 63 14.60 3991 2 40
3 3 5280.5 884 10 14.83 3879 2 39
4 3 5118.8 0 1 14.97 3902 2 37
5 7 5132.1 3843 80 14.85 3754 2 45
6 13 4256.3 4044 80 14.77 3253 2 47
7 13 2928.9 4328 80 14.89 2415 2 49
8 13 1988.8 4508 80 14.98 1814 2 53
9 13 1208.3 4636 80 15.06 1305 2 51
10 13 945.0 4672 80 15.05 1123 2 45
11 13 744.7 4694 80 15.03 984 2 43
12 14 0.1 4770 86 15.09 456 3 111
13 14 0.2 4770 14 15.07 446 53 247

Cycle 30 GMT 1/ 1/2023 5:50: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 45 15.11 487 3 18
2 6 5430.2 614 63 14.60 4011 2 39
3 3 5428.0 855 19 14.77 3947 2 39
4 3 5150.6 0 2 14.94 3929 2 37
5 7 5168.7 3843 80 14.85 3751 2 45
6 13 4153.9 4084 80 14.80 3155 2 47
7 13 2950.5 4348 80 14.89 2423 2 48
8 13 1989.2 4532 80 14.98 1816 2 53
9 13 1263.5 4648 80 15.05 1348 2 51
10 13 969.9 4688 80 15.04 1152 2 46
11 13 726.0 4714 80 15.03 981 2 43
12 14 -0.2 4789 86 15.09 456 2 107
13 14 -0.2 4789 14 15.08 452 53 247

Cycle 29 GMT 28/12/2022 3:34: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.7 9 70 15.11 501 3 21
2 6 5004.8 632 62 14.66 3730 2 42
3 3 4619.6 873 6 14.91 3476 2 40
4 3 4518.5 0 1 15.01 3559 2 38
5 7 4512.1 963 80 14.88 3419 2 46
6 13 3552.8 1184 80 14.86 2815 2 47
7 13 2377.2 1432 80 14.97 2062 2 49
8 13 1708.3 1548 80 15.01 1631 2 54
9 13 989.4 1652 80 15.09 1155 2 48
10 13 740.8 1682 80 15.08 981 2 41
11 14 0.1 1766 127 15.12 450 2 111

Cycle 28 GMT 26/12/2022 3:25: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.7 9 72 15.11 500 3 22
2 6 5003.7 676 62 14.67 3743 2 40
3 7 4453.5 963 80 14.90 3395 2 46
4 13 3454.6 1203 80 14.89 2760 2 47
5 13 2218.8 1479 80 15.00 1975 2 50
6 13 1753.9 1559 80 15.01 1670 2 53
7 13 991.8 1671 80 15.09 1161 2 48
8 13 737.5 1702 80 15.08 988 2 41
9 14 -0.1 1785 125 15.12 453 2 116

Cycle 27 GMT 24/12/2022 2:12: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.3 9 70 15.11 504 3 21
2 6 5007.2 649 62 14.67 3765 2 41
3 3 4531.7 890 1 14.95 3590 2 37
4 7 4538.3 963 80 14.89 3474 2 46
5 13 3588.6 1180 80 14.87 2873 2 47
6 13 2443.5 1416 80 14.96 2148 2 50
7 13 1613.9 1560 80 15.04 1592 2 54
8 13 989.3 1656 80 15.10 1171 2 48
9 13 737.6 1686 80 15.09 993 2 41
10 14 -0.1 1770 127 15.13 450 2 110

Cycle 26 GMT 22/12/2022 1:42: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.7 10 117 15.13 496 3 21
2 6 4004.2 540 61 14.80 3136 2 42
3 3 3624.9 722 6 15.00 2892 2 41
4 7 3499.7 1565 80 15.00 2819 2 47
5 13 2724.0 1734 80 14.98 2317 2 49
6 13 1986.8 1862 80 15.01 1835 2 53
7 13 990.0 2014 80 15.13 1176 2 48
8 13 962.6 2018 80 15.07 1145 3 43
9 13 732.0 2040 80 15.06 987 2 48
10 14 0.1 2111 67 15.13 466 2 103
11 14 0.0 2112 33 15.11 452 52 247

Cycle 25 GMT 20/12/2022 14:19: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.8 10 118 15.11 507 3 21
2 6 4003.6 563 61 14.81 3131 2 42
3 3 3530.4 744 1 15.03 2912 2 36
4 7 3462.4 482 80 15.01 2793 2 46
5 13 2553.5 695 80 15.01 2219 2 49
6 13 1981.1 795 80 15.01 1834 2 53
7 13 998.7 947 80 15.14 1187 2 49
8 13 750.6 977 80 15.12 1012 2 41
9 14 0.0 1066 144 15.15 456 2 117

Cycle 24 GMT 19/12/2022 1:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 10 119 15.14 506 3 23
2 6 4007.1 573 62 14.82 3128 2 42
3 3 3542.4 754 2 15.03 2942 2 38
4 7 3424.6 482 80 15.02 2771 2 46
5 13 2532.0 687 80 15.02 2208 2 49
6 13 1865.5 803 80 15.04 1757 2 53
7 13 998.9 935 80 15.14 1184 2 48
8 13 970.9 939 80 15.07 1151 2 43
9 13 738.0 961 80 15.07 995 2 49
10 14 0.0 1032 63 15.13 468 3 102
11 14 0.1 1033 37 15.12 443 46 247

Cycle 23 GMT 17/12/2022 13:59: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 10 130 15.13 517 3 22
2 6 4002.3 636 61 14.83 3144 2 43
3 7 3233.2 482 80 15.06 2658 2 47
4 13 2316.6 691 80 15.05 2068 2 50
5 13 1835.2 771 80 15.04 1749 2 53
6 13 981.8 895 80 15.14 1175 2 48
7 13 726.7 925 80 15.13 994 2 41
8 14 0.0 1005 127 15.16 465 2 105

Cycle 22 GMT 16/12/2022 1:26:58

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.5 10 138 15.05 503 3 23
2 6 4004.9 601 61 14.81 3133 2 42
3 7 3314.1 482 80 15.04 2696 2 47
4 13 2359.6 707 80 15.05 2089 2 49
5 13 1819.6 803 80 15.05 1739 2 53
6 13 997.3 923 80 15.14 1198 2 48
7 13 734.5 955 80 15.13 1008 2 41
8 14 0.0 1039 133 15.16 471 3 106

Cycle 21 GMT 14/12/2022 12:53: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.0 10 125 15.07 518 3 23
2 6 4008.2 326 61 14.82 3152 2 42
3 3 3793.3 508 16 14.96 3003 2 42
4 3 3539.9 689 2 15.10 2987 2 37
5 7 3508.8 1352 80 15.01 2830 2 46
6 13 2525.7 1584 80 15.02 2216 2 49
7 13 1989.8 1679 80 15.01 1855 2 53
8 13 1116.0 1808 80 14.99 1279 2 49
9 13 458.0 1894 80 15.03 816 2 38
10 14 -0.1 1955 148 15.08 461 2 106

Cycle 20 GMT 13/12/2022 1: 3:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.6 10 148 14.69 484 3 21
2 6 3867.8 541 61 14.84 3089 2 43
3 7 2931.6 1565 80 15.10 2461 2 47
4 13 2000.8 1772 80 15.10 1868 2 50
5 13 998.7 1964 80 15.04 1208 2 49
6 13 729.7 2004 80 15.02 1015 2 42
7 13 598.2 2020 80 14.99 911 2 46
8 14 0.0 2092 110 15.08 475 3 105

Cycle 19 GMT 11/12/2022 11: 1: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.8 10 155 14.72 487 2 21
2 6 4003.1 413 61 14.80 3141 2 42
3 7 3315.2 1437 80 15.04 2720 2 46
4 13 2446.5 1634 80 15.01 2165 2 48
5 13 1981.8 1711 80 14.98 1863 2 52
6 13 1968.8 1713 80 14.85 1827 3 51
7 13 1952.0 1714 80 14.75 1799 3 47
8 13 1932.3 1716 80 14.65 1775 2 49
9 13 1910.0 1718 80 14.55 1749 3 98
10 13 1885.2 1720 80 14.52 1395 42 247
11 13 1858.8 1722 80 14.64 504 247 247
12 13 1831.8 1723 80 14.62 569 247 247
13 13 1805.5 1725 80 14.63 467 247 247
14 13 1779.0 1727 80 14.62 482 247 247
15 13 1752.6 1729 80 14.61 438 247 247
16 13 1726.4 1731 80 14.60 441 247 247
17 13 1700.5 1733 80 14.61 389 247 247
18 13 1674.1 1734 80 14.60 384 247 247
19 13 1647.8 1736 80 14.59 385 247 247
20 13 1621.9 1738 80 14.58 406 247 247
21 13 1595.7 1740 80 14.57 382 247 247
22 13 1490.9 1747 80 14.53 373 247 247
23 13 1464.4 1749 80 14.52 382 247 247
24 13 1438.1 1751 80 14.51 412 247 247
25 13 1412.2 1753 80 14.50 409 247 247
26 13 1386.6 1755 80 14.49 395 247 247
27 13 1361.0 1756 80 14.47 396 247 247
28 13 1336.0 1758 80 14.47 392 247 247
29 13 1311.5 1760 80 14.45 397 247 247
30 13 1286.9 1762 80 14.44 372 247 247
31 13 1261.7 1764 80 14.43 368 247 247
32 13 1236.6 1766 80 14.42 387 247 247
33 13 1211.4 1767 80 14.42 358 247 247
34 13 1186.0 1769 80 14.41 357 247 247
35 13 1160.7 1771 80 14.40 367 247 247
36 13 1136.0 1773 80 14.39 379 247 247
37 13 1111.1 1775 80 14.38 374 247 247
38 13 1086.1 1777 80 14.37 391 247 247
39 13 1061.2 1778 80 14.36 376 247 247
40 13 1036.5 1780 80 14.35 371 247 247
41 13 1011.8 1782 80 14.35 362 247 247
42 13 986.9 1784 80 14.34 366 247 247
43 13 888.2 1791 80 14.31 364 247 247
44 13 863.9 1793 80 14.30 366 247 247
45 13 839.8 1795 80 14.30 360 247 247
46 13 815.9 1797 80 14.29 357 247 247
47 13 792.4 1799 80 14.29 365 247 247
48 13 769.1 1800 80 14.28 363 247 247
49 13 740.7 1803 80 14.28 356 247 247
50 14 0.1 1867 100 14.65 402 247 247

Cycle 18 GMT 10/12/2022 0:38:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.6 11 201 15.10 515 3 21
2 6 3004.4 249 61 14.97 2495 2 42
3 3 2654.0 430 8 15.12 2280 2 41
4 7 2524.4 1274 80 15.16 2203 2 47
5 13 1982.2 1379 80 15.09 1833 2 52
6 13 1970.7 1381 80 14.97 1808 3 52
7 13 1954.9 1383 80 14.87 1781 3 48
8 13 1935.9 1385 80 14.76 1769 3 45
9 13 1913.9 1386 80 14.67 1734 2 65
10 13 1889.9 1388 80 14.60 1607 13 247
11 13 1864.2 1390 80 14.69 716 247 247
12 13 1837.9 1392 80 14.72 484 247 247
13 13 1811.5 1394 80 14.71 509 247 247
14 13 1785.1 1396 80 14.70 474 247 247
15 13 1758.9 1397 80 14.71 407 247 247
16 13 1732.8 1399 80 14.69 461 247 247
17 13 1707.2 1401 80 14.68 419 247 247
18 13 1681.7 1403 80 14.67 441 247 247
19 13 1656.6 1405 80 14.66 449 247 247
20 13 1631.6 1407 80 14.66 412 247 247
21 13 1606.4 1408 80 14.65 409 247 247
22 13 1504.6 1416 80 14.61 406 247 247
23 13 1479.0 1418 80 14.60 417 247 247
24 13 1453.2 1419 80 14.59 414 247 247
25 13 1426.9 1421 80 14.59 400 247 247
26 13 1400.6 1423 80 14.58 397 247 247
27 13 1374.3 1425 80 14.57 407 247 247
28 13 1347.8 1427 80 14.56 371 247 247
29 13 1321.4 1429 80 14.56 360 247 247
30 13 1294.4 1430 80 14.55 361 247 247
31 13 1267.6 1432 80 14.54 361 247 247
32 13 1241.1 1434 80 14.53 361 247 247
33 13 1215.0 1436 80 14.53 360 247 247
34 13 1189.0 1438 80 14.51 361 247 247
35 13 1163.3 1440 80 14.50 404 247 247
36 13 1138.4 1441 80 14.49 385 247 247
37 13 1113.7 1443 80 14.48 383 247 247
38 13 1089.1 1445 80 14.47 380 247 247
39 13 1064.7 1447 80 14.46 384 247 247
40 13 1039.7 1449 80 14.45 359 247 247
41 13 1014.1 1450 80 14.45 350 247 247
42 13 989.1 1452 80 14.44 350 247 247
43 13 889.1 1460 80 14.40 369 247 247
44 13 864.7 1461 80 14.39 374 247 247
45 13 840.1 1463 80 14.38 365 247 247
46 13 815.9 1465 80 14.37 367 247 247
47 13 791.8 1467 80 14.37 347 247 247
48 13 767.7 1469 80 14.36 343 247 247
49 13 738.3 1471 80 14.36 342 247 247
50 14 0.2 1533 100 14.67 402 246 247

Cycle 17 GMT 8/12/2022 19:52:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.8 11 207 15.27 498 3 23
2 6 3002.9 299 60 15.03 2487 2 42
3 7 2365.6 1324 80 15.20 2084 2 47
4 13 1985.6 1395 80 15.12 1841 2 52
5 13 748.7 1598 80 15.10 1019 2 45
6 13 613.6 1616 80 15.07 914 2 42
7 14 -0.2 1695 157 15.14 456 3 105

Cycle 16 GMT 7/12/2022 12:28: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.6 13 333 15.25 507 3 22
2 6 1008.0 192 43 15.27 1168 2 34
3 3 826.3 313 1 15.37 1109 2 31
4 7 805.8 1038 80 15.43 1042 2 40
5 13 781.4 1043 80 15.38 997 3 39
6 13 742.5 1048 80 15.33 960 3 43
7 13 376.2 1084 80 15.33 715 3 53
8 14 0.0 1119 43 15.33 462 8 107
9 14 -0.1 1120 57 15.31 437 52 247

Cycle 15 GMT 6/12/2022 17:40: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.4 13 335 15.25 518 3 22
2 6 1006.4 202 43 15.27 1154 2 34
3 7 738.9 1047 80 15.45 987 2 40
4 13 713.4 1053 80 15.40 942 3 38
5 13 673.8 1058 80 15.35 907 3 43
6 13 374.1 1088 80 15.34 712 3 53
7 14 0.1 1123 41 15.34 459 3 118
8 14 0.1 1124 59 15.32 437 59 247

Cycle 14 GMT 5/12/2022 22:48:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.2 13 335 15.26 521 3 22
2 6 1008.6 197 43 15.28 1160 3 34
3 3 821.0 318 1 15.38 1105 2 29
4 7 771.8 1043 80 15.44 1019 2 40
5 13 750.9 1048 80 15.39 985 3 38
6 13 714.7 1053 80 15.34 946 2 43
7 13 389.8 1086 80 15.34 726 3 55
8 14 0.1 1124 43 15.33 460 4 105
9 14 0.1 1125 57 15.31 442 53 247

Cycle 13 GMT 5/12/2022 3:57: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.8 13 333 15.26 521 3 22
2 6 1008.4 191 43 15.27 1166 3 34
3 3 840.9 312 2 15.37 1124 2 30
4 7 791.4 1037 80 15.44 1026 2 40
5 13 767.0 1042 80 15.39 1002 3 39
6 13 387.1 1088 80 15.38 758 2 42
7 14 0.0 1134 123 15.34 477 3 117

Cycle 12 GMT 4/12/2022 8:56: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.3 13 328 15.26 526 2 22
2 6 1010.3 179 43 15.27 1172 2 33
3 3 900.3 300 5 15.35 1153 2 33
4 7 815.6 1025 80 15.44 1051 2 40
5 13 791.9 1030 80 15.38 1010 3 39
6 13 383.8 1080 80 15.37 759 2 42
7 14 0.1 1126 125 15.34 490 3 117

Cycle 11 GMT 3/12/2022 14: 1: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.0 13 315 15.29 534 3 21
2 6 1010.1 171 43 15.27 1173 3 33
3 3 1046.9 293 12 15.34 1240 2 35
4 3 887.8 414 4 15.39 1172 2 35
5 7 804.8 1018 80 15.43 1063 2 40
6 13 782.0 1023 80 15.38 1025 3 39
7 13 212.0 1096 80 15.40 650 2 41
8 13 170.6 1100 80 15.36 613 3 53
9 14 -0.1 1116 41 15.36 490 4 109
10 14 0.0 1117 59 15.34 457 51 247

Cycle 10 GMT 2/12/2022 19:15:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 40.5 11 317 15.31 513 3 22
2 6 1007.3 203 43 15.29 1177 3 34
3 7 742.3 1048 80 15.45 1019 2 39
4 13 718.1 1053 80 15.40 983 3 38
5 13 183.6 1118 80 15.41 627 3 42
6 14 -0.1 1139 116 15.37 499 3 107

Cycle 9 GMT 2/12/2022 0:10: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 31.0 10 280 15.30 504 3 19
2 6 1009.4 146 57 15.25 1168 3 31
3 3 1270.2 268 34 15.28 1368 2 38
4 3 941.4 389 17 15.34 1185 2 38
5 3 651.8 509 2 15.42 1036 2 29
6 7 483.5 993 80 15.47 834 3 38
7 13 457.1 998 80 15.43 803 3 37
8 13 187.1 1031 80 15.41 626 3 43
9 14 0.0 1051 101 15.38 499 3 104

Cycle 8 GMT 1/12/2022 6:32: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 30.5 10 280 15.29 512 3 19
2 6 1809.3 310 58 15.04 1736 2 39
3 3 1485.3 432 45 15.15 1551 2 44
4 3 1037.4 553 22 15.26 1275 2 42
5 3 634.3 674 1 15.37 1047 2 30
6 7 314.1 1158 80 15.48 716 3 35
7 13 289.2 1162 80 15.44 687 3 34
8 14 0.1 1201 174 15.38 484 3 114

Cycle 7 GMT 30/11/2022 10:22:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 26.5 11 334 15.28 501 3 22
2 6 1006.3 202 57 15.27 1176 2 35
3 3 689.7 323 4 15.37 1022 2 33
4 7 450.3 1047 80 15.49 814 2 37
5 13 424.7 1052 80 15.44 782 3 36
6 14 0.1 1106 178 15.38 489 3 103

Cycle 6 GMT 29/11/2022 15:49: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.3 12 307 15.28 522 3 20
2 6 1592.4 311 58 15.06 1583 2 40
3 3 1204.9 433 30 15.19 1373 2 42
4 3 788.1 554 9 15.31 1116 2 37
5 7 349.2 1158 80 15.48 745 3 36
6 13 325.6 1162 80 15.43 718 3 34
7 14 -0.1 1207 174 15.38 492 2 104

Cycle 5 GMT 28/11/2022 19:35:59

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.9 12 307 15.28 521 3 20
2 6 1584.1 311 58 15.06 1585 2 40
3 3 1191.5 433 30 15.19 1366 2 42
4 3 795.5 554 9 15.31 1136 2 38
5 7 353.1 1158 80 15.48 749 3 35
6 13 328.9 1163 80 15.43 719 3 34
7 14 0.0 1207 176 15.37 495 3 106

Cycle 4 GMT 27/11/2022 23:21: 2

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.5 12 307 15.23 528 3 21
2 6 1603.0 311 58 15.03 1607 2 40
3 3 1208.3 433 31 15.17 1383 2 43
4 3 793.7 554 9 15.28 1142 2 37
5 7 335.6 1158 80 15.47 744 3 35
6 13 313.2 1162 80 15.43 710 3 33
7 14 0.0 1204 176 15.37 494 3 111

Cycle 3 GMT 27/11/2022 3:11: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.7 12 307 14.93 524 3 21
2 6 1644.5 311 58 14.88 1601 2 40
3 3 1280.6 433 34 15.03 1406 2 43
4 3 855.6 554 12 15.17 1163 2 39
5 7 354.7 1158 80 15.43 744 3 35
6 13 331.2 1162 80 15.38 716 3 33
7 14 0.2 1207 178 15.33 500 3 112

Cycle 2 GMT 26/11/2022 6:54: 1

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.7 12 307 15.04 536 3 20
2 6 -99.0 322 55 14.94 1639 2 40
3 7 1164.3 197 80 15.00 1331 2 45
4 13 991.0 230 80 14.97 1208 2 43
5 13 342.2 320 80 14.99 752 2 39
6 14 -0.1 365 155 15.01 500 3 105

Cycle 1 GMT 25/11/2022 10:42:58

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.4 12 307 15.24 477 3 20
2 6 -99.0 321 55 15.08 1625 2 40
3 7 1154.3 197 80 15.12 1316 2 45
4 13 1006.7 225 80 15.09 1231 2 43
5 13 251.4 328 80 15.11 728 2 39
6 14 -0.1 363 153 15.11 528 3 108

Cycle 0 GMT 24/11/2022 14:39: 0

Pump Count Mission Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 156.2 50475 435 15.50 562 3 25
2 7 226.3 50478 80 15.40 565 3 24
3 13 201.6 50482 80 15.36 549 3 24
4 14 0.5 50510 168 15.32 437 3 101