SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 3254 WMO= 5906960


Cycle 19 GMT 17/12/2024 20:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 30 15.21 419 2 2
2 7 2004.24 38 14.94 2830 2 4
3 13 1328.36 18 15.05 2030 2 6
4 13 749.72 18 15.15 1288 2 7
5 13 322.60 18 15.24 716 2 5
6 8 0.04 165 15.25 272 2 14

Cycle 18 GMT 8/12/2024 1: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 30 15.21 414 2 2
2 10 1005.00 2 15.27 1649 2 3
3 3 963.44 -1 15.60 0 2 3
4 7 2009.76 38 14.96 2832 2 4
5 13 1335.44 18 15.05 2025 2 7
6 13 743.44 18 15.16 1278 2 7
7 13 318.56 18 15.24 718 2 6
8 13 52.28 18 15.28 355 2 4
9 8 0.16 165 15.25 275 2 13

Cycle 17 GMT 28/11/2024 5:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 15.20 396 2 2
2 7 2004.56 38 14.95 2852 2 5
3 13 1285.04 18 15.07 1996 2 7
4 13 810.08 18 15.14 1374 2 9
5 13 363.84 18 15.24 781 2 6
6 13 49.20 18 15.29 343 2 4
7 8 0.24 165 15.26 269 2 14

Cycle 16 GMT 18/11/2024 10:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 30 15.20 400 2 2
2 7 2010.60 38 14.96 2840 2 4
3 13 1321.36 18 15.05 2021 2 7
4 13 818.20 18 15.15 1364 2 7
5 13 364.56 18 15.24 776 2 7
6 13 52.52 18 15.29 349 2 4
7 8 0.28 165 15.25 273 2 15

Cycle 15 GMT 8/11/2024 15:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 30 15.20 420 2 2
2 7 2008.16 38 14.97 2833 2 4
3 13 1284.16 18 15.08 1970 2 6
4 13 793.96 18 15.16 1343 2 6
5 13 313.72 18 15.25 708 2 5
6 13 50.64 18 15.29 349 2 5
7 8 0.12 165 15.26 277 2 14

Cycle 14 GMT 29/10/2024 19:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 15.20 385 2 2
2 7 2007.68 38 14.97 2823 2 4
3 13 1289.80 18 15.06 1980 2 6
4 13 847.68 18 15.14 1414 2 7
5 13 306.56 18 15.25 701 2 5
6 13 50.68 18 15.29 352 2 5
7 8 -0.36 165 15.25 272 2 14

Cycle 13 GMT 20/10/2024 0:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 15.21 388 2 2
2 7 2004.92 38 14.96 2844 2 5
3 13 1263.40 18 15.07 1958 2 6
4 13 785.00 18 15.17 1318 2 7
5 13 391.96 18 15.25 810 2 6
6 13 39.00 18 15.30 328 2 5
7 8 0.16 165 15.26 264 2 14

Cycle 12 GMT 10/10/2024 5:18: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 30 15.22 409 2 2
2 7 2007.88 39 14.97 2840 2 5
3 13 1320.12 18 15.08 2019 2 6
4 13 822.12 18 15.16 1377 2 8
5 13 293.60 18 15.26 681 2 5
6 13 42.72 18 15.30 332 2 4
7 8 -0.08 165 15.27 264 2 16

Cycle 11 GMT 30/ 9/2024 10: 2:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 30 15.24 400 2 2
2 7 2004.20 38 14.97 2873 2 5
3 13 1293.04 18 15.07 1969 2 6
4 13 771.44 18 15.17 1308 2 7
5 13 343.32 18 15.25 747 2 5
6 13 37.60 18 15.30 330 2 5
7 8 -0.24 165 15.26 266 2 12

Cycle 10 GMT 20/ 9/2024 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 15.22 380 2 2
2 7 2008.72 39 14.99 2831 2 4
3 13 1330.36 18 15.09 2027 2 6
4 13 907.72 18 15.15 1491 2 7
5 13 268.88 18 15.28 639 2 5
6 13 34.44 18 15.32 318 2 4
7 8 0.12 165 15.28 265 2 13

Cycle 9 GMT 10/ 9/2024 19:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 15.22 402 2 2
2 7 2005.80 38 14.99 2841 2 3
3 13 1239.56 18 15.11 1896 2 6
4 13 795.20 18 15.16 1352 2 7
5 13 353.28 18 15.25 768 2 5
6 13 40.40 18 15.32 334 2 4
7 8 -0.36 165 15.26 263 2 12

Cycle 8 GMT 31/ 8/2024 23:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 29 15.23 412 2 2
2 7 2006.24 38 14.99 2818 2 4
3 13 1331.16 18 15.08 2014 2 4
4 13 786.76 18 15.17 1327 2 7
5 13 344.20 18 15.26 750 2 5
6 13 39.28 18 15.32 333 2 4
7 8 -0.36 165 15.28 269 2 9

Cycle 7 GMT 22/ 8/2024 4:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 29 15.24 398 2 2
2 3 1019.48 1 15.34 1656 2 2
3 7 2004.76 38 14.98 2847 2 5
4 13 1168.32 18 15.10 1821 2 5
5 13 745.24 18 15.19 1263 2 7
6 13 319.52 18 15.27 714 2 6
7 13 36.64 18 15.31 321 2 4
8 8 0.24 165 15.27 260 2 10

Cycle 6 GMT 12/ 8/2024 9:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 28 15.24 353 2 2
2 3 1022.44 1 15.35 1640 2 3
3 7 2006.96 38 15.00 2825 2 4
4 13 1203.28 18 15.13 1852 2 5
5 13 782.16 18 15.19 1302 2 8
6 13 293.08 18 15.28 639 2 6
7 13 26.44 18 15.32 274 2 6
8 8 -0.24 165 15.28 237 2 13

Cycle 5 GMT 2/ 8/2024 13:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 30 15.26 390 2 2
2 3 942.20 -1 15.68 0 2 2
3 7 2007.12 74 14.89 2811 2 6
4 13 486.08 18 15.26 905 2 6
5 13 87.80 18 15.32 365 2 5
6 13 16.12 18 15.32 267 2 5
7 8 -0.20 165 15.29 237 2 14

Cycle 4 GMT 23/ 7/2024 16:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 28 15.26 385 2 2
2 7 1526.56 74 15.06 2238 2 5
3 13 311.12 18 15.32 675 2 5
4 13 33.48 18 15.35 294 2 4
5 8 -0.16 165 15.31 240 2 13

Cycle 3 GMT 22/ 7/2024 16:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 28 15.27 384 2 2
2 3 971.80 -1 15.68 0 2 2
3 3 1028.16 1 15.38 1663 2 2
4 7 1507.92 74 15.06 2208 2 7
5 13 270.44 18 15.32 621 2 5
6 13 26.84 18 15.35 287 2 5
7 8 -0.32 165 15.32 240 2 13

Cycle 2 GMT 21/ 7/2024 17:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 32 15.30 386 2 2
2 3 847.36 -3 15.70 0 2 2
3 7 1517.96 74 15.07 2226 2 6
4 13 290.68 18 15.32 634 2 5
5 13 27.96 18 15.37 282 2 6
6 8 0.08 165 15.32 239 2 13

Cycle 1 GMT 20/ 7/2024 17:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 27 15.47 344 3 3
2 7 989.08 75 15.24 1542 2 11
3 8 0.04 165 15.38 240 2 12

Cycle 0 GMT 20/ 7/2024 7: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 27 15.61 332 3 14
2 7 118.44 75 15.59 357 3 3
3 8 0.32 240 15.55 191 3 14