SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 3262 WMO= 5906968


Cycle 3 GMT 26/ 7/2024 17:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 30 15.29 401 2 2
2 7 1506.76 74 15.03 2170 2 4
3 13 325.52 18 15.35 708 2 5
4 13 142.16 18 15.36 448 2 5
5 13 77.00 18 15.35 354 2 6
6 8 0.00 165 15.33 245 2 18

Cycle 2 GMT 25/ 7/2024 18: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 32 15.35 394 2 2
2 3 893.84 -2 15.71 0 2 2
3 7 1507.68 75 15.05 2161 2 4
4 13 317.04 18 15.35 691 2 5
5 13 141.00 18 15.36 446 2 6
6 13 80.76 18 15.35 360 2 6
7 8 0.32 165 15.33 248 2 18

Cycle 1 GMT 24/ 7/2024 18:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 27 15.52 361 3 4
2 10 1029.32 2 15.39 1644 2 3
3 7 998.96 74 15.23 1540 2 9
4 13 77.20 18 15.45 357 2 7
5 8 0.12 165 15.41 247 2 10

Cycle 0 GMT 24/ 7/2024 7:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 90.72 27 15.67 322 3 3
2 7 110.88 74 15.65 366 3 16
3 13 60.68 18 15.64 284 3 3
4 8 0.12 240 15.60 209 3 18