SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 29 | 15.23 | 441 | 3 | 3 |
2 | 7 | 2010.76 | 38 | 14.98 | 2789 | 2 | 3 |
3 | 13 | 1463.52 | 18 | 15.02 | 2153 | 2 | 4 |
4 | 13 | 978.24 | 18 | 15.09 | 1553 | 2 | 5 |
5 | 13 | 268.16 | 18 | 15.25 | 646 | 2 | 7 |
6 | 8 | 0.16 | 165 | 15.27 | 289 | 2 | 14 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 29 | 15.23 | 438 | 3 | 3 |
2 | 7 | 2011.56 | 38 | 14.98 | 2783 | 2 | 3 |
3 | 13 | 1436.00 | 18 | 15.02 | 2113 | 2 | 4 |
4 | 13 | 916.28 | 18 | 15.10 | 1476 | 2 | 5 |
5 | 13 | 324.04 | 18 | 15.23 | 719 | 2 | 7 |
6 | 8 | 0.20 | 165 | 15.27 | 287 | 2 | 18 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 29 | 15.25 | 429 | 3 | 3 |
2 | 7 | 2015.64 | 38 | 14.97 | 2791 | 2 | 3 |
3 | 13 | 1484.28 | 18 | 15.02 | 2168 | 2 | 4 |
4 | 13 | 947.52 | 18 | 15.10 | 1511 | 2 | 5 |
5 | 13 | 230.84 | 18 | 15.27 | 597 | 2 | 7 |
6 | 8 | 0.04 | 165 | 15.27 | 286 | 2 | 17 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 29 | 15.25 | 437 | 3 | 3 |
2 | 7 | 2006.04 | 38 | 14.99 | 2753 | 2 | 3 |
3 | 13 | 1472.64 | 18 | 15.03 | 2159 | 2 | 3 |
4 | 13 | 982.32 | 18 | 15.10 | 1555 | 2 | 5 |
5 | 13 | 279.92 | 18 | 15.26 | 659 | 2 | 7 |
6 | 8 | 0.16 | 165 | 15.28 | 285 | 2 | 17 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 31 | 15.25 | 427 | 2 | 3 |
2 | 3 | 903.08 | -2 | 15.62 | 0 | 2 | 3 |
3 | 3 | 1032.40 | 1 | 15.34 | 1664 | 2 | 3 |
4 | 7 | 2016.08 | 74 | 14.87 | 2757 | 2 | 4 |
5 | 13 | 655.96 | 18 | 15.18 | 1122 | 2 | 6 |
6 | 8 | 0.20 | 165 | 15.29 | 283 | 2 | 18 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 28 | 15.25 | 422 | 2 | 3 |
2 | 7 | 1821.00 | 74 | 14.92 | 2553 | 2 | 4 |
3 | 13 | 551.16 | 18 | 15.20 | 997 | 2 | 6 |
4 | 8 | 0.32 | 165 | 15.30 | 280 | 2 | 13 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 28 | 15.26 | 428 | 2 | 3 |
2 | 3 | 1027.08 | 1 | 15.34 | 1637 | 2 | 3 |
3 | 7 | 1806.64 | 74 | 14.94 | 2535 | 2 | 4 |
4 | 13 | 469.88 | 18 | 15.23 | 890 | 2 | 6 |
5 | 8 | 0.20 | 165 | 15.29 | 277 | 2 | 13 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 28 | 15.26 | 423 | 2 | 3 |
2 | 7 | 1821.00 | 74 | 14.93 | 2548 | 2 | 4 |
3 | 13 | 436.40 | 18 | 15.24 | 847 | 2 | 6 |
4 | 8 | 0.00 | 165 | 15.30 | 274 | 2 | 14 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 29 | 15.27 | 423 | 3 | 3 |
2 | 3 | 928.08 | -1 | 15.61 | 0 | 3 | 3 |
3 | 7 | 1517.96 | 74 | 15.05 | 2185 | 2 | 4 |
4 | 13 | 407.24 | 18 | 15.27 | 811 | 2 | 6 |
5 | 8 | -0.08 | 165 | 15.31 | 270 | 2 | 15 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 30 | 15.25 | 438 | 3 | 3 |
2 | 7 | 1514.32 | 74 | 15.06 | 2174 | 3 | 4 |
3 | 13 | 425.96 | 18 | 15.25 | 834 | 2 | 6 |
4 | 8 | -0.08 | 165 | 15.32 | 269 | 2 | 17 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 33 | 15.28 | 425 | 2 | 3 |
2 | 3 | 829.32 | -3 | 15.63 | 0 | 2 | 3 |
3 | 7 | 1528.64 | 74 | 15.03 | 2187 | 2 | 4 |
4 | 13 | 424.00 | 18 | 15.24 | 824 | 2 | 6 |
5 | 8 | 0.08 | 165 | 15.30 | 269 | 2 | 14 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 28 | 15.44 | 375 | 3 | 3 |
2 | 7 | 1001.28 | 74 | 15.20 | 1526 | 2 | 7 |
3 | 8 | 0.04 | 165 | 15.36 | 269 | 2 | 18 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 87.32 | 28 | 15.57 | 357 | 3 | 3 |
2 | 7 | 102.20 | 74 | 15.54 | 372 | 3 | 3 |
3 | 8 | 0.64 | 240 | 15.51 | 231 | 3 | 16 |