SIO Argo AUX Buoyancy Pumping Time Series Data: |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 31 | 15.19 | 429 | 2 | 2 |
2 | 7 | 2011.88 | 38 | 14.89 | 2825 | 2 | 5 |
3 | 13 | 1304.20 | 18 | 14.99 | 1970 | 2 | 5 |
4 | 13 | 767.40 | 18 | 15.09 | 1304 | 2 | 9 |
5 | 13 | 253.24 | 18 | 15.22 | 636 | 2 | 10 |
6 | 13 | 16.16 | 18 | 15.26 | 309 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.23 | 282 | 2 | 19 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 31 | 15.20 | 429 | 2 | 2 |
2 | 7 | 2004.24 | 39 | 14.90 | 2826 | 2 | 3 |
3 | 13 | 1258.92 | 18 | 15.00 | 1915 | 2 | 6 |
4 | 13 | 814.28 | 18 | 15.08 | 1360 | 2 | 9 |
5 | 13 | 208.24 | 18 | 15.22 | 578 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.23 | 282 | 2 | 17 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 31 | 15.22 | 425 | 2 | 2 |
2 | 7 | 2009.44 | 75 | 14.77 | 2816 | 2 | 7 |
3 | 13 | 461.00 | 18 | 15.17 | 912 | 2 | 10 |
4 | 13 | 20.72 | 18 | 15.27 | 315 | 2 | 8 |
5 | 8 | 0.04 | 165 | 15.24 | 283 | 2 | 19 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 30 | 15.22 | 422 | 2 | 2 |
2 | 10 | 1011.16 | 2 | 15.24 | 1643 | 2 | 3 |
3 | 7 | 2007.44 | 74 | 14.78 | 2813 | 2 | 6 |
4 | 13 | 517.64 | 18 | 15.16 | 984 | 2 | 8 |
5 | 13 | 20.32 | 18 | 15.27 | 314 | 2 | 8 |
6 | 8 | 0.12 | 165 | 15.25 | 281 | 2 | 19 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 31 | 15.21 | 425 | 2 | 2 |
2 | 3 | 969.64 | -1 | 15.59 | 0 | 2 | 2 |
3 | 7 | 2004.84 | 74 | 14.78 | 2816 | 2 | 6 |
4 | 13 | 423.60 | 18 | 15.19 | 861 | 2 | 10 |
5 | 13 | 20.92 | 18 | 15.28 | 311 | 2 | 8 |
6 | 8 | 0.00 | 165 | 15.24 | 277 | 2 | 18 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 29 | 15.21 | 431 | 2 | 2 |
2 | 7 | 1819.84 | 74 | 14.86 | 2587 | 2 | 7 |
3 | 13 | 375.04 | 18 | 15.21 | 800 | 2 | 9 |
4 | 13 | 20.40 | 18 | 15.28 | 313 | 2 | 8 |
5 | 8 | 0.00 | 165 | 15.24 | 281 | 2 | 18 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 29 | 15.21 | 429 | 2 | 2 |
2 | 3 | 1023.32 | 1 | 15.28 | 1643 | 2 | 4 |
3 | 7 | 1818.24 | 74 | 14.86 | 2584 | 2 | 9 |
4 | 13 | 411.96 | 18 | 15.19 | 842 | 2 | 9 |
5 | 13 | 13.00 | 18 | 15.27 | 299 | 2 | 8 |
6 | 8 | 0.12 | 165 | 15.24 | 279 | 2 | 21 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 29 | 15.23 | 427 | 2 | 2 |
2 | 7 | 1807.92 | 74 | 14.86 | 2568 | 2 | 7 |
3 | 13 | 360.92 | 18 | 15.21 | 775 | 2 | 8 |
4 | 13 | 16.04 | 18 | 15.28 | 304 | 2 | 9 |
5 | 8 | 0.08 | 165 | 15.24 | 280 | 2 | 20 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 29 | 15.23 | 421 | 2 | 2 |
2 | 7 | 1506.88 | 74 | 14.98 | 2196 | 2 | 6 |
3 | 13 | 333.96 | 18 | 15.24 | 739 | 2 | 7 |
4 | 8 | 0.24 | 165 | 15.27 | 281 | 2 | 18 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 27 | 15.24 | 419 | 2 | 2 |
2 | 10 | 1016.60 | 2 | 15.24 | 1643 | 2 | 3 |
3 | 7 | 1507.92 | 75 | 14.98 | 2193 | 2 | 6 |
4 | 13 | 322.64 | 18 | 15.25 | 714 | 2 | 9 |
5 | 8 | 0.12 | 165 | 15.27 | 278 | 2 | 17 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 33 | 15.28 | 407 | 2 | 2 |
2 | 3 | 830.68 | -3 | 15.61 | 0 | 2 | 2 |
3 | 3 | 924.24 | -1 | 15.63 | 0 | 2 | 2 |
4 | 7 | 1521.60 | 74 | 14.98 | 2203 | 2 | 6 |
5 | 13 | 302.92 | 18 | 15.26 | 692 | 2 | 8 |
6 | 8 | 0.04 | 165 | 15.27 | 272 | 2 | 15 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 28 | 15.43 | 368 | 2 | 2 |
2 | 7 | 990.56 | 74 | 15.16 | 1553 | 2 | 9 |
3 | 8 | -0.12 | 165 | 15.32 | 273 | 2 | 20 |
Pump Count | Mission Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 87.40 | 28 | 15.59 | 322 | 2 | 3 |
2 | 7 | 104.44 | 74 | 15.55 | 368 | 2 | 4 |
3 | 8 | 0.44 | 240 | 15.50 | 225 | 2 | 17 |