SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 3234 WMO= 6990601


Cycle 28 GMT 21/12/2024 1:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 15.18 431 2 8
2 7 2011.04 38 14.89 2858 2 14
3 13 1517.60 18 14.95 2277 2 18
4 13 904.48 18 15.09 1517 2 19
5 13 317.88 18 15.23 755 2 21
6 13 53.72 18 15.29 371 2 16
7 8 0.16 165 15.26 282 2 13

Cycle 27 GMT 11/12/2024 6:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 15.19 431 2 9
2 7 2005.64 38 14.88 2852 2 15
3 13 1500.76 18 14.96 2267 2 17
4 13 896.72 18 15.07 1518 2 21
5 13 413.80 18 15.18 882 2 21
6 13 66.60 18 15.28 394 2 18
7 13 16.04 18 15.29 314 2 11
8 8 0.04 165 15.25 285 2 17

Cycle 26 GMT 1/12/2024 11:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 30 15.21 426 2 8
2 7 2005.20 38 14.90 2844 2 14
3 13 1561.36 18 14.96 2328 2 17
4 13 947.88 18 15.08 1575 2 20
5 13 496.36 18 15.17 990 2 20
6 13 79.80 18 15.28 415 2 20
7 8 0.12 165 15.25 281 2 15

Cycle 25 GMT 21/11/2024 17: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 15.21 417 2 8
2 7 2010.80 38 14.89 2861 2 15
3 13 1506.48 18 14.97 2274 2 18
4 13 855.36 18 15.08 1458 2 20
5 13 368.28 18 15.20 820 2 20
6 13 81.08 18 15.28 412 2 20
7 8 0.12 165 15.26 280 2 18

Cycle 24 GMT 11/11/2024 22: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 30 15.21 418 2 8
2 7 2008.96 38 14.90 2850 2 14
3 13 1516.44 18 14.96 2275 2 17
4 13 920.72 18 15.08 1535 2 20
5 13 416.08 18 15.20 890 2 21
6 13 37.44 18 15.29 339 2 10
7 13 14.24 18 15.29 308 2 10
8 8 -0.04 165 15.25 282 2 18

Cycle 23 GMT 2/11/2024 3: 6: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 30 15.22 420 2 7
2 7 2007.52 38 14.91 2848 2 15
3 13 1420.76 18 15.00 2165 2 18
4 13 900.88 18 15.08 1517 2 20
5 13 351.16 18 15.22 795 2 21
6 13 69.72 18 15.29 400 2 19
7 13 19.24 18 15.30 312 2 11
8 8 -0.12 165 15.26 280 2 16

Cycle 22 GMT 23/10/2024 8: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 30 15.21 424 2 7
2 7 2011.64 38 14.91 2853 2 14
3 13 1421.52 18 15.01 2170 2 17
4 13 982.24 18 15.08 1618 2 19
5 13 428.80 18 15.21 898 2 21
6 13 74.88 18 15.30 405 2 19
7 13 20.00 18 15.31 308 2 10
8 8 0.00 165 15.27 275 2 24

Cycle 21 GMT 13/10/2024 13: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 30 15.20 421 2 8
2 7 2004.40 38 14.90 2844 2 15
3 13 1517.36 18 14.98 2278 2 18
4 13 969.92 18 15.08 1595 2 20
5 13 376.28 18 15.22 826 2 20
6 13 83.80 18 15.29 425 2 20
7 13 20.92 18 15.30 314 2 11
8 8 0.04 165 15.26 277 2 17

Cycle 20 GMT 3/10/2024 18: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 30 15.21 417 2 7
2 7 2007.72 38 14.91 2845 2 15
3 13 1584.28 18 14.97 2358 2 16
4 13 1011.88 18 15.06 1651 2 19
5 13 501.60 18 15.18 1000 2 21
6 13 58.32 18 15.30 377 2 18
7 13 15.92 18 15.31 307 2 10
8 8 -0.20 165 15.26 280 2 18

Cycle 19 GMT 23/ 9/2024 23: 5: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 30 15.22 412 2 7
2 7 2008.92 38 14.91 2849 2 14
3 13 1441.84 18 15.00 2189 2 19
4 13 997.88 18 15.07 1640 2 20
5 13 357.76 18 15.23 806 2 20
6 13 75.56 18 15.29 405 2 19
7 13 19.76 18 15.30 310 2 10
8 8 -0.04 165 15.26 275 2 16

Cycle 18 GMT 14/ 9/2024 4: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 29 15.22 410 2 6
2 7 2003.60 38 14.92 2844 2 14
3 13 1463.48 18 14.99 2214 2 18
4 13 874.28 18 15.11 1485 2 19
5 13 385.56 18 15.22 842 2 20
6 13 51.20 18 15.30 368 2 17
7 13 19.64 18 15.31 311 2 10
8 8 0.08 165 15.26 276 2 18

Cycle 17 GMT 4/ 9/2024 8:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 15.24 410 2 6
2 7 2004.04 38 14.91 2838 2 14
3 13 1460.84 18 15.01 2217 2 17
4 13 957.72 18 15.09 1590 2 19
5 13 355.00 18 15.23 799 2 21
6 13 37.08 18 15.32 343 2 15
7 13 24.92 18 15.32 310 2 11
8 8 0.04 165 15.27 271 2 15

Cycle 16 GMT 25/ 8/2024 13:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 15.24 415 2 7
2 7 2003.96 38 14.92 2855 2 15
3 13 1459.92 18 15.01 2216 2 17
4 13 911.64 18 15.11 1534 2 20
5 13 358.00 18 15.25 806 2 21
6 13 37.88 18 15.32 344 2 13
7 13 14.68 18 15.32 303 2 10
8 8 0.12 165 15.27 277 2 17

Cycle 15 GMT 15/ 8/2024 18:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 15.25 413 2 6
2 7 2007.00 38 14.93 2854 2 14
3 13 1452.24 18 15.02 2201 2 19
4 13 906.00 18 15.11 1529 2 20
5 13 359.28 18 15.25 812 2 21
6 13 48.44 18 15.32 364 2 17
7 8 0.12 165 15.29 279 2 16

Cycle 14 GMT 5/ 8/2024 23:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 29 15.25 419 2 7
2 7 2008.12 38 14.94 2856 2 15
3 13 1474.80 18 15.03 2239 2 18
4 13 959.88 18 15.10 1600 2 20
5 13 298.96 18 15.28 724 2 21
6 13 77.24 18 15.32 412 2 20
7 8 0.08 165 15.29 278 2 19

Cycle 13 GMT 27/ 7/2024 4:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 29 15.24 422 2 7
2 7 2003.04 38 14.94 2845 2 15
3 13 1502.16 18 15.03 2267 2 18
4 13 944.76 18 15.11 1576 2 20
5 13 337.12 18 15.27 779 2 21
6 13 67.28 18 15.33 395 2 18
7 13 17.68 18 15.33 308 2 10
8 8 0.04 165 15.30 278 2 17

Cycle 12 GMT 17/ 7/2024 9:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 29 15.24 423 2 8
2 7 2006.28 38 14.94 2852 2 15
3 13 1511.68 18 15.01 2279 2 18
4 13 956.68 18 15.11 1588 2 21
5 13 452.16 18 15.22 935 2 22
6 13 64.40 18 15.31 386 2 19
7 8 0.16 165 15.30 277 2 15

Cycle 11 GMT 7/ 7/2024 14:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 29 15.27 428 2 9
2 7 2003.00 38 14.93 2849 2 15
3 13 1416.72 18 15.04 2161 2 19
4 13 886.60 18 15.13 1503 2 21
5 13 342.32 18 15.25 782 2 21
6 13 72.60 18 15.32 401 2 19
7 8 0.04 165 15.29 274 2 17

Cycle 10 GMT 27/ 6/2024 19:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 29 15.26 440 2 8
2 3 1020.88 1 15.30 1721 2 13
3 7 2002.92 38 14.97 2854 2 14
4 13 1514.00 18 15.03 2282 2 18
5 13 1008.72 18 15.12 1659 2 20
6 13 337.96 18 15.27 778 2 21
7 13 73.00 18 15.33 402 2 20
8 8 0.04 165 15.32 278 2 20

Cycle 9 GMT 18/ 6/2024 0:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 28 15.26 421 2 8
2 3 1021.84 1 15.29 1717 2 13
3 7 2004.80 38 14.96 2850 2 15
4 13 1424.48 18 15.05 2176 2 18
5 13 903.12 18 15.13 1523 2 21
6 13 347.00 18 15.26 793 2 21
7 13 108.80 18 15.32 470 2 21
8 8 0.00 165 15.31 283 2 17

Cycle 8 GMT 8/ 6/2024 5:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 29 15.26 420 2 8
2 3 957.00 -1 15.65 0 2 8
3 7 2006.80 74 14.84 2833 2 16
4 13 463.72 18 15.24 941 2 21
5 13 126.80 18 15.32 484 2 21
6 8 0.16 165 15.32 275 2 16

Cycle 7 GMT 29/ 5/2024 8:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 15.26 423 2 8
2 7 1778.76 75 14.92 2558 2 16
3 13 340.24 18 15.28 773 2 21
4 13 115.12 18 15.32 462 2 21
5 8 0.08 165 15.31 271 2 15

Cycle 6 GMT 28/ 5/2024 7:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 27 15.26 416 2 7
2 3 1022.08 1 15.34 1737 2 15
3 7 1794.24 74 14.91 2575 2 15
4 13 507.60 18 15.23 1001 2 21
5 13 102.80 18 15.33 447 2 20
6 8 0.12 165 15.31 274 2 14

Cycle 5 GMT 27/ 5/2024 6:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 27 15.28 427 2 7
2 7 1805.28 74 14.91 2591 2 16
3 13 409.16 18 15.25 867 2 21
4 13 119.56 18 15.32 471 2 21
5 8 0.16 165 15.31 273 2 21

Cycle 4 GMT 26/ 5/2024 6: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 27 15.28 423 2 8
2 7 1526.36 74 15.03 2253 2 16
3 13 255.20 18 15.33 657 2 20
4 13 96.20 18 15.36 437 2 20
5 8 0.04 165 15.33 274 2 15

Cycle 3 GMT 25/ 5/2024 6:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 26 15.26 413 2 7
2 3 1061.40 2 15.31 1788 2 16
3 7 1520.48 74 15.03 2239 2 17
4 13 305.08 18 15.30 723 2 21
5 13 86.84 18 15.36 424 2 20
6 8 0.00 165 15.32 278 2 18

Cycle 2 GMT 24/ 5/2024 6:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 32 15.33 415 2 8
2 3 825.40 -3 15.67 0 2 8
3 3 918.60 -2 15.69 0 2 8
4 7 1523.68 74 15.03 2242 2 16
5 13 307.28 18 15.30 729 2 20
6 13 88.36 18 15.35 423 2 20
7 8 -0.08 165 15.32 275 2 18

Cycle 1 GMT 23/ 5/2024 7:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 27 15.52 363 2 4
2 7 991.88 74 15.20 1565 2 18
3 8 0.04 165 15.39 277 2 18

Cycle 0 GMT 22/ 5/2024 20:47: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 98.80 26 15.67 373 2 4
2 7 115.80 74 15.64 387 2 7
3 8 0.16 240 15.60 222 2 18