SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8448 WMO= 7900668


Cycle 358 GMT 16/11/2024 15:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 31 10.55 506 2 2
2 12 2000.48 92 7.30 3067 2 2
3 7 1994.84 22 7.35 3065 2 2
4 13 1861.24 40 7.65 2862 2 2
5 13 1033.44 40 8.89 1768 2 2
6 13 460.40 40 9.85 1008 2 2
7 13 15.60 40 10.71 382 2 3
8 8 0.00 180 10.75 358 2 10

Cycle 357 GMT 15/11/2024 13:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 10.55 511 2 2
2 3 1035.64 1 8.97 1775 2 2
3 3 1015.12 1 9.24 1751 2 2
4 12 1130.60 92 8.62 1884 2 2
5 7 1124.80 22 8.72 1875 2 2
6 13 563.68 40 9.67 1138 2 2
7 13 46.48 5 10.72 424 2 3
8 8 0.08 180 10.76 352 2 4

Cycle 356 GMT 5/11/2024 19: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 33 10.55 519 2 2
2 3 969.48 -1 10.55 519 2 2
3 3 1013.68 1 9.20 1743 2 2
4 12 1138.40 92 8.64 1905 2 2
5 7 1132.64 22 8.78 1901 2 2
6 13 554.64 40 9.72 1130 2 2
7 13 45.44 5 10.73 421 2 3
8 13 42.76 5 10.70 432 2 3
9 13 17.64 40 10.71 386 2 3
10 8 -0.20 180 10.76 356 2 5

Cycle 355 GMT 27/10/2024 1: 3:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 33 10.63 501 2 2
2 12 1105.72 92 8.78 1864 2 2
3 7 1100.32 22 8.86 1871 2 2
4 13 405.88 40 10.02 935 2 3
5 8 0.12 180 10.78 359 2 6

Cycle 354 GMT 17/10/2024 6:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 35 10.61 496 2 2
2 3 930.80 -1 10.61 496 2 2
3 3 973.00 -1 10.61 496 2 2
4 12 1998.76 92 7.76 3059 2 2
5 7 1992.20 22 7.82 3060 2 2
6 13 1440.36 40 8.57 2316 2 2
7 13 856.24 40 9.40 1555 2 2
8 13 144.44 5 10.61 571 2 3
9 13 62.80 5 10.73 463 2 3
10 13 41.80 5 10.77 442 2 3
11 13 16.32 40 10.76 389 2 3
12 8 0.08 180 10.81 361 2 11

Cycle 353 GMT 16/10/2024 4:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 32 10.61 511 2 2
2 3 961.80 -1 10.61 511 2 2
3 12 1125.64 92 8.85 1886 2 2
4 7 1119.40 22 8.98 1888 2 2
5 13 672.88 40 9.66 1287 2 2
6 8 0.20 180 10.81 353 2 4

Cycle 352 GMT 6/10/2024 10:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 34 10.63 502 2 2
2 3 951.52 -1 10.63 502 2 2
3 12 1115.72 92 8.96 1866 2 2
4 7 1109.32 22 9.03 1869 2 2
5 13 525.16 40 9.93 1084 2 2
6 13 16.88 40 10.79 375 2 3
7 13 4.80 40 10.80 359 2 4
8 8 0.04 180 10.82 349 2 10

Cycle 351 GMT 26/ 9/2024 16:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 31 10.65 508 2 2
2 10 1005.48 5 9.39 1724 2 2
3 3 944.88 -1 9.39 1724 2 2
4 12 1086.84 92 9.04 1832 2 2
5 7 1080.64 22 9.07 1829 2 2
6 13 509.84 40 9.98 1068 2 3
7 8 0.28 180 10.83 351 2 8

Cycle 350 GMT 16/ 9/2024 22:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 31 10.70 507 2 2
2 10 1023.76 4 9.35 1776 2 2
3 12 1998.44 92 8.10 3065 2 2
4 7 1991.80 22 8.06 3073 2 2
5 13 1278.08 40 9.04 2122 2 2
6 13 714.36 40 9.78 1355 2 2
7 13 121.92 5 10.72 536 2 3
8 8 -0.04 180 10.87 356 2 5

Cycle 349 GMT 15/ 9/2024 20:14: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 32 10.70 500 2 2
2 12 1112.28 92 9.04 1878 2 2
3 7 1105.68 22 9.14 1872 2 2
4 13 506.24 40 10.02 1064 2 3
5 8 0.08 180 10.84 358 2 4

Cycle 348 GMT 6/ 9/2024 2:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 31 10.67 520 2 2
2 12 1125.52 92 9.09 1882 2 2
3 7 1119.48 22 9.16 1892 2 2
4 13 418.12 40 10.19 945 2 3
5 13 45.80 5 10.82 432 2 3
6 13 42.64 5 10.82 431 2 3
7 8 0.20 180 10.85 356 2 8

Cycle 347 GMT 27/ 8/2024 8:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 29 10.73 509 2 2
2 3 1029.88 1 9.66 1761 2 2
3 3 1017.28 1 9.77 1746 2 2
4 12 1141.40 92 9.12 1913 2 2
5 7 1134.92 22 9.22 1904 2 2
6 13 530.52 40 10.07 1098 2 3
7 13 64.20 5 10.81 457 2 3
8 13 17.60 40 10.84 379 2 3
9 8 0.36 180 10.87 351 2 8

Cycle 346 GMT 17/ 8/2024 14: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 10.69 513 2 2
2 12 1999.48 92 8.37 3068 2 2
3 7 1992.36 22 8.42 3052 2 2
4 13 1147.88 40 9.41 1925 2 2
5 13 581.28 40 10.07 1177 2 3
6 13 17.60 40 10.86 390 2 3
7 8 -0.16 180 10.90 359 2 6

Cycle 345 GMT 16/ 8/2024 11:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 31 10.71 520 2 2
2 3 1015.16 1 9.70 1748 2 2
3 12 1107.40 92 9.22 1866 2 2
4 7 1100.76 22 9.31 1870 2 2
5 13 365.92 11 10.34 878 2 3
6 13 133.00 5 10.75 558 2 3
7 13 87.76 5 10.81 491 2 3
8 13 62.04 5 10.82 462 2 3
9 13 40.48 5 10.83 434 2 3
10 8 0.24 180 10.87 357 2 8

Cycle 344 GMT 6/ 8/2024 17:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 31 10.76 505 2 2
2 3 968.80 -1 10.76 505 2 2
3 12 1144.68 92 9.19 1930 2 3
4 7 1137.96 22 9.33 1922 3 2
5 13 391.36 12 10.34 920 2 3
6 13 143.36 5 10.74 568 2 3
7 13 94.40 5 10.82 507 2 3
8 13 66.36 5 10.83 467 2 3
9 8 0.80 180 10.89 356 2 7

Cycle 343 GMT 27/ 7/2024 22:56: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 31 10.79 505 2 3
2 12 1081.28 92 9.34 1836 2 2
3 7 1073.40 22 9.41 1834 2 3
4 13 330.64 10 10.47 831 2 3
5 13 205.84 5 10.67 661 2 3
6 13 126.04 5 10.77 547 2 3
7 13 43.36 5 10.89 433 2 3
8 13 15.96 40 10.86 383 2 3
9 8 0.24 180 10.89 358 2 3

Cycle 342 GMT 18/ 7/2024 4:52: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 10.76 508 2 2
2 12 1998.48 92 8.58 3073 2 2
3 7 1991.60 22 8.73 3044 2 2
4 13 1561.40 40 9.11 2489 2 2
5 13 535.44 40 10.23 1111 2 3
6 13 4.00 40 10.93 365 2 4
7 8 -0.24 180 10.94 352 2 14

Cycle 341 GMT 17/ 7/2024 2:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 29 10.75 520 2 3
2 3 1034.44 1 9.79 1767 2 2
3 12 1115.60 92 9.32 1881 2 2
4 7 1108.84 22 9.43 1879 2 2
5 13 390.56 12 10.38 923 2 3
6 13 143.08 5 10.73 577 2 3
7 13 88.32 5 10.84 496 2 3
8 13 64.20 5 10.85 465 2 3
9 8 0.16 180 10.91 352 2 4

Cycle 340 GMT 7/ 7/2024 8: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 31 10.76 514 2 2
2 12 1105.36 92 9.35 1875 2 2
3 7 1097.92 22 9.46 1868 2 2
4 13 474.44 40 10.27 1023 2 3
5 8 0.04 180 10.92 356 2 6

Cycle 339 GMT 27/ 6/2024 14:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 10.81 513 2 3
2 3 1042.32 1 9.90 1787 2 2
3 3 1021.12 1 10.02 1748 2 2
4 12 1127.84 92 9.39 1896 2 2
5 7 1121.60 22 9.48 1902 2 2
6 13 361.00 11 10.46 870 2 3
7 13 232.48 6 10.68 695 2 3
8 13 86.52 5 10.87 491 2 3
9 13 65.48 5 10.87 470 2 3
10 13 53.16 5 10.89 451 2 3
11 13 46.72 5 10.90 443 2 3
12 13 43.44 5 10.89 438 2 3
13 8 0.16 180 10.92 352 2 10

Cycle 338 GMT 17/ 6/2024 20: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 10.77 524 2 2
2 3 1034.40 1 9.90 1781 2 2
3 12 2005.00 92 8.71 3084 2 2
4 7 1998.32 22 8.82 3055 2 2
5 13 1289.24 40 9.50 2135 2 2
6 13 574.80 40 10.24 1172 2 3
7 8 0.16 180 10.96 357 2 11

Cycle 337 GMT 16/ 6/2024 17:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 10.79 508 2 2
2 3 953.44 -1 10.79 508 2 2
3 12 1116.12 92 9.42 1890 2 2
4 7 1109.20 22 9.52 1876 2 2
5 13 360.56 11 10.47 881 2 3
6 13 124.60 5 10.81 548 2 3
7 13 57.88 5 10.89 454 2 3
8 13 48.72 5 10.89 449 2 3
9 8 -0.16 180 10.92 357 2 6

Cycle 336 GMT 6/ 6/2024 23:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 30 10.80 505 2 2
2 3 957.92 -1 10.80 505 2 2
3 3 1024.96 1 10.02 1755 2 2
4 12 1101.60 92 9.45 1866 2 2
5 7 1094.28 22 9.57 1858 2 2
6 13 354.20 10 10.51 865 2 3
7 13 120.92 5 10.83 540 2 3
8 13 78.88 5 10.88 487 2 3
9 13 44.08 5 10.91 440 2 3
10 13 40.80 5 10.91 428 2 3
11 13 5.64 40 10.92 366 2 3
12 8 0.28 180 10.93 351 2 6

Cycle 335 GMT 28/ 5/2024 5:32: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 29 10.86 509 2 2
2 3 1026.04 1 10.00 1767 2 2
3 12 1103.76 92 9.50 1870 2 2
4 7 1095.72 22 9.57 1859 2 2
5 13 493.16 40 10.31 1050 2 3
6 8 0.36 180 10.95 353 2 4

Cycle 334 GMT 18/ 5/2024 11:37:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 30 10.82 509 2 2
2 12 1997.32 92 8.86 3079 2 2
3 7 1989.36 22 9.02 3041 2 2
4 13 1245.64 40 9.64 2074 2 2
5 13 343.84 10 10.59 856 2 3
6 13 216.76 6 10.80 674 2 3
7 13 120.72 5 10.88 544 2 3
8 13 81.04 5 10.92 491 2 3
9 13 59.80 5 10.97 452 2 3
10 13 4.88 40 10.98 363 2 5
11 8 -0.44 180 10.98 347 2 4

Cycle 333 GMT 17/ 5/2024 8:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 29 10.80 515 2 2
2 3 1048.56 2 9.95 1804 2 2
3 12 1125.00 92 9.50 1897 2 2
4 7 1117.48 22 9.67 1884 2 2
5 13 350.00 10 10.54 855 2 3
6 13 223.44 6 10.72 680 2 3
7 13 80.56 5 10.90 481 2 3
8 13 60.68 5 10.89 460 2 3
9 13 50.64 5 10.92 444 2 3
10 8 0.40 180 10.95 348 2 5

Cycle 332 GMT 7/ 5/2024 14:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 31 10.85 502 2 2
2 3 963.92 -1 10.85 502 2 2
3 12 1132.24 92 9.52 1910 2 2
4 7 1124.96 22 9.64 1900 2 2
5 13 349.04 10 10.56 859 2 3
6 13 220.52 6 10.69 686 2 3
7 13 75.36 5 10.90 482 2 3
8 13 47.60 5 10.96 438 2 3
9 13 44.00 5 10.94 441 2 3
10 13 40.96 5 10.91 443 2 4
11 8 -0.32 180 10.95 351 2 5

Cycle 331 GMT 27/ 4/2024 20:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 29 10.85 506 2 2
2 3 1043.04 2 10.02 1813 2 2
3 12 1123.08 92 9.56 1897 2 2
4 7 1116.80 22 9.63 1898 2 2
5 13 253.28 7 10.70 723 2 3
6 13 152.16 5 10.84 585 2 3
7 13 91.88 5 10.91 504 2 3
8 13 71.48 5 10.92 476 2 3
9 13 54.76 5 10.93 451 2 3
10 8 0.28 180 10.97 344 2 7

Cycle 330 GMT 18/ 4/2024 2:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 28 10.85 513 2 2
2 3 1037.80 1 10.03 1800 2 2
3 12 2005.56 92 8.94 3096 2 2
4 7 1998.84 22 8.97 3131 2 2
5 13 1264.56 40 9.71 2110 2 2
6 13 374.80 11 10.59 899 2 3
7 13 134.48 5 10.90 554 2 3
8 13 84.32 5 10.94 491 2 3
9 13 62.16 5 10.98 460 2 3
10 13 44.96 5 10.99 440 2 3
11 8 -0.04 180 10.99 349 2 7

Cycle 329 GMT 16/ 4/2024 23:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 30 10.82 517 2 2
2 3 965.20 -1 10.82 517 2 2
3 3 1022.16 1 10.05 1756 2 2
4 12 1141.16 92 9.54 1929 2 2
5 7 1134.24 22 9.71 1906 2 2
6 13 493.36 40 10.36 1056 2 3
7 8 0.00 180 10.96 350 2 5

Cycle 328 GMT 7/ 4/2024 5:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 10.87 502 2 2
2 3 958.44 -1 10.87 502 2 2
3 12 1125.04 92 9.59 1896 2 2
4 7 1118.36 22 9.73 1894 2 2
5 13 465.44 40 10.41 1014 2 3
6 13 15.52 40 10.95 373 2 3
7 8 -0.12 180 10.97 346 2 10

Cycle 327 GMT 28/ 3/2024 12: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 27 10.88 512 2 2
2 3 1071.32 2 9.99 1857 2 2
3 3 1021.52 1 10.12 1774 2 2
4 12 1135.92 92 9.63 1905 2 2
5 7 1129.36 22 9.73 1912 2 2
6 13 235.24 6 10.76 694 2 3
7 13 139.40 5 10.86 573 2 3
8 13 95.72 5 10.91 504 2 3
9 13 17.40 40 10.95 376 2 3
10 8 0.04 180 10.97 344 2 7

Cycle 326 GMT 18/ 3/2024 17:55: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 30 10.91 523 2 2
2 3 956.60 -1 10.91 523 2 2
3 12 2003.60 92 9.11 3089 2 2
4 7 1996.16 22 9.20 3076 2 2
5 13 1099.20 40 9.89 1887 2 2
6 13 365.24 11 10.62 879 2 3
7 13 128.40 5 10.87 558 2 3
8 13 85.08 5 10.94 489 2 3
9 13 17.56 40 10.96 383 2 4
10 8 0.04 180 10.98 351 2 11

Cycle 325 GMT 17/ 3/2024 15:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 30 10.96 511 2 2
2 12 1118.84 92 9.68 1895 2 2
3 7 1112.56 22 9.86 1886 2 2
4 13 515.12 40 10.43 1088 2 3
5 8 0.20 180 11.02 354 2 10

Cycle 324 GMT 7/ 3/2024 21:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 29 11.10 504 2 2
2 3 965.00 -1 11.10 504 2 2
3 12 1154.36 92 9.72 1946 2 2
4 7 1147.40 22 9.90 1936 2 2
5 13 245.84 40 10.82 699 2 3
6 8 -0.04 180 11.09 356 2 7

Cycle 323 GMT 27/ 2/2024 3:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 11.13 516 2 2
2 3 1025.04 1 10.46 1753 2 2
3 12 1110.00 92 9.81 1882 2 2
4 7 1101.96 22 9.97 1870 2 2
5 13 164.60 40 10.99 578 2 3
6 8 0.00 180 11.18 353 2 12

Cycle 322 GMT 17/ 2/2024 9:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 27 11.22 499 2 2
2 10 1017.80 5 10.27 1803 2 2
3 3 969.80 -1 10.27 1803 2 2
4 12 2001.64 92 9.16 3093 2 2
5 7 1994.00 22 9.26 3073 2 2
6 13 999.16 40 10.17 1736 2 2
7 13 251.80 40 10.90 709 2 3
8 8 -0.04 180 11.19 352 2 14

Cycle 321 GMT 16/ 2/2024 7:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 28 11.36 502 2 2
2 3 1032.44 1 10.50 1775 2 2
3 3 1028.40 1 10.53 1769 2 2
4 12 1118.04 92 9.66 1893 2 2
5 7 1110.48 22 9.88 1882 2 2
6 13 334.32 40 10.86 813 2 3
7 8 0.00 180 11.26 350 2 9

Cycle 320 GMT 6/ 2/2024 13:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 30 11.51 498 2 2
2 3 966.92 -1 11.51 498 2 2
3 12 1128.72 92 10.20 1914 2 2
4 7 1120.80 22 10.23 1911 2 2
5 13 173.84 5 11.36 606 2 3
6 13 112.84 5 11.40 534 2 3
7 13 55.16 5 11.48 447 2 3
8 13 47.12 5 11.49 438 2 3
9 8 0.12 180 11.41 347 2 4

Cycle 319 GMT 27/ 1/2024 19:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 27 11.56 504 2 2
2 10 1027.60 4 11.00 1798 2 2
3 3 964.72 -1 11.00 1798 2 2
4 3 1016.88 1 10.72 1775 2 2
5 12 1110.24 92 10.09 1884 2 2
6 7 1102.12 22 10.27 1878 2 2
7 13 164.44 5 11.37 603 2 3
8 13 100.52 5 11.45 516 2 3
9 13 71.00 5 11.50 480 2 4
10 13 54.28 5 11.53 460 2 4
11 8 0.08 180 11.50 350 2 10

Cycle 318 GMT 18/ 1/2024 1:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 26 11.89 517 2 2
2 10 1030.92 5 11.57 1813 2 2
3 3 965.76 -1 11.57 1813 2 2
4 3 970.44 -1 11.57 1813 2 2
5 12 2001.68 92 9.60 3106 2 2
6 7 1994.24 22 9.64 3091 2 2
7 13 1087.84 40 10.41 1872 2 2
8 13 99.56 5 11.52 510 2 4
9 13 71.04 5 11.52 479 2 3
10 13 54.72 5 11.52 459 2 4
11 8 0.28 180 11.53 356 2 5

Cycle 317 GMT 16/ 1/2024 23:20: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 25 12.41 509 2 3
2 10 1008.20 5 12.17 1785 2 3
3 3 928.76 -1 12.17 1785 2 3
4 12 1099.84 92 9.74 1866 2 2
5 7 1092.88 22 10.27 1869 2 2
6 13 175.72 5 11.67 622 2 4
7 13 109.60 5 11.76 532 2 4
8 13 71.76 5 11.82 476 2 4
9 13 57.24 5 11.82 462 2 4
10 13 48.00 5 11.82 445 2 4
11 8 -0.08 180 11.80 354 2 6

Cycle 316 GMT 7/ 1/2024 5:26: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 26 12.60 520 2 3
2 3 1031.00 1 11.91 1798 2 2
3 12 1131.84 92 10.50 1930 2 2
4 7 1123.92 22 10.92 1920 2 2
5 13 88.72 5 12.27 495 2 4
6 13 64.80 5 12.27 476 2 4
7 13 45.08 5 12.29 454 2 4
8 13 41.84 5 12.28 449 2 4
9 8 0.16 180 12.29 360 2 8

Cycle 315 GMT 28/12/2023 11:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 26 12.85 534 2 3
2 12 1129.52 92 10.34 1919 2 2
3 7 1122.32 22 10.90 1917 2 2
4 13 90.16 5 12.37 502 2 4
5 13 69.04 5 12.38 480 2 4
6 13 55.20 5 12.38 466 2 4
7 13 47.20 5 12.41 458 2 5
8 13 43.60 5 12.35 454 2 4
9 13 40.52 5 12.35 451 2 4
10 8 0.16 180 12.40 367 2 11

Cycle 314 GMT 18/12/2023 17:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 24 13.24 521 2 3
2 3 1057.80 2 12.07 1883 2 2
3 12 1997.08 92 10.04 3104 2 2
4 7 1988.68 22 10.28 3109 2 2
5 13 756.20 40 11.85 1411 2 3
6 13 59.28 5 12.67 476 2 4
7 13 49.16 5 12.69 466 2 4
8 8 0.04 180 12.61 372 2 19

Cycle 313 GMT 17/12/2023 15:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 24 13.55 541 2 4
2 3 1033.00 1 12.20 1836 2 2
3 12 1127.56 92 9.92 1910 2 2
4 7 1120.80 22 10.79 1920 2 2
5 13 170.52 5 13.04 630 2 5
6 13 112.72 5 13.10 562 2 5
7 13 42.92 5 13.22 467 2 4
8 8 0.20 180 13.04 375 2 9

Cycle 312 GMT 7/12/2023 21:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 26 13.64 541 2 3
2 12 1100.96 92 10.27 1883 2 2
3 7 1094.12 22 11.04 1892 2 2
4 13 175.88 5 13.39 643 2 5
5 13 73.16 5 13.52 495 2 4
6 13 55.16 5 13.56 486 2 5
7 13 47.36 5 13.55 482 2 5
8 13 43.52 5 13.51 471 2 5
9 8 0.08 180 13.30 385 2 9

Cycle 311 GMT 28/11/2023 3:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 23 13.78 538 2 4
2 3 1056.16 2 12.68 1863 2 2
3 3 1018.84 1 12.02 1805 2 2
4 12 1096.60 92 10.44 1874 2 2
5 7 1088.52 22 11.16 1877 2 2
6 13 147.80 5 13.54 595 2 6
7 13 17.20 40 13.70 411 2 5
8 8 0.04 180 13.23 370 2 9

Cycle 310 GMT 18/11/2023 9:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 25 13.82 533 2 4
2 3 970.28 -1 13.82 533 2 4
3 12 1994.88 92 10.33 3101 2 2
4 7 1986.36 22 10.70 3083 2 2
5 13 585.56 40 13.10 1195 2 5
6 8 0.12 180 13.50 385 2 8

Cycle 309 GMT 17/11/2023 7:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 26 13.89 546 2 4
2 3 968.04 -1 13.89 546 2 4
3 12 1120.88 92 9.74 1904 2 2
4 7 1112.80 22 10.90 1923 2 2
5 13 192.32 5 13.63 670 2 6
6 13 110.04 5 13.70 569 2 5
7 13 71.68 5 13.79 511 2 5
8 13 54.76 5 13.86 495 2 5
9 13 16.00 40 13.91 426 2 5
10 8 -0.16 180 13.44 383 2 11

Cycle 308 GMT 7/11/2023 13: 7:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 25 13.91 545 2 4
2 3 971.84 -1 13.91 545 2 4
3 12 1149.44 92 10.02 1942 2 2
4 7 1143.24 22 11.05 1951 2 2
5 13 127.28 5 13.71 579 2 5
6 13 87.96 5 13.81 531 2 5
7 13 65.16 5 13.85 505 2 5
8 13 52.96 5 13.88 485 2 5
9 8 0.16 180 13.63 393 2 6

Cycle 307 GMT 28/10/2023 19: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 25 13.97 546 2 4
2 12 1097.44 92 10.54 1883 2 2
3 7 1089.40 22 11.28 1899 2 3
4 13 120.00 5 13.77 573 2 5
5 13 79.12 5 13.84 515 2 6
6 13 57.84 5 13.87 495 2 5
7 13 17.24 40 13.96 431 2 5
8 8 -0.28 180 13.54 384 2 11

Cycle 306 GMT 19/10/2023 1:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 25 14.00 541 2 4
2 12 2004.92 92 10.32 3120 2 2
3 7 1997.12 22 10.74 3120 2 2
4 13 660.68 40 13.18 1321 2 5
5 8 0.20 180 13.68 395 2 11

Cycle 305 GMT 17/10/2023 23:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 24 13.99 547 2 4
2 3 1034.76 1 12.17 1834 2 2
3 12 1099.80 92 9.96 1875 2 2
4 7 1092.12 22 11.08 1883 2 2
5 13 148.28 5 13.76 608 2 6
6 13 61.68 5 13.85 495 2 5
7 8 0.12 180 13.72 384 2 10

Cycle 304 GMT 8/10/2023 5:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 26 14.01 547 2 4
2 3 964.92 -1 14.01 547 2 4
3 3 1023.48 1 12.19 1815 2 2
4 12 1101.20 92 10.19 1888 2 2
5 7 1092.76 22 11.21 1891 2 3
6 13 130.64 5 13.80 586 2 5
7 13 85.24 5 13.84 530 2 5
8 13 2.36 40 14.00 403 2 6
9 8 0.12 180 13.67 386 2 26

Cycle 303 GMT 28/ 9/2023 11:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 26 13.96 542 2 4
2 12 1085.44 92 10.54 1869 2 2
3 7 1076.84 22 11.41 1871 2 3
4 13 57.80 5 13.91 477 2 4
5 13 48.76 5 13.87 479 2 5
6 8 0.36 180 13.75 389 2 10

Cycle 302 GMT 18/ 9/2023 17:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 25 13.95 543 2 4
2 12 1997.60 92 10.46 3118 2 2
3 7 1988.16 22 10.87 3094 2 2
4 13 793.16 40 13.09 1483 2 4
5 8 0.08 180 13.76 388 2 6

Cycle 301 GMT 17/ 9/2023 15:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 24 14.01 527 2 5
2 10 1013.36 4 12.94 1823 2 3
3 3 945.28 -1 12.94 1823 2 3
4 3 971.56 -1 12.94 1823 2 3
5 12 1132.08 92 9.92 1912 2 2
6 7 1125.24 22 11.09 1931 2 2
7 13 202.28 5 13.75 683 2 6
8 13 113.48 5 13.84 565 2 5
9 13 74.36 5 13.89 513 2 5
10 8 0.16 180 13.75 393 2 9

Cycle 300 GMT 7/ 9/2023 21:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 26 13.97 559 2 4
2 12 1094.48 92 10.18 1877 2 2
3 7 1087.16 22 11.25 1875 2 2
4 13 134.92 5 13.87 592 2 6
5 13 61.12 5 13.90 496 2 5
6 8 0.32 180 13.76 391 2 12

Cycle 299 GMT 29/ 8/2023 3:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 24 14.06 534 2 4
2 3 1040.40 1 12.75 1859 2 2
3 3 1017.80 1 12.32 1798 2 2
4 12 1100.24 92 10.47 1885 2 2
5 7 1092.52 22 11.40 1898 2 3
6 13 91.32 5 13.89 520 2 5
7 13 64.52 5 13.92 500 2 5
8 13 44.80 5 13.97 474 2 5
9 13 41.92 5 13.95 479 2 5
10 8 0.56 180 13.81 391 2 5

Cycle 298 GMT 19/ 8/2023 9:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 25 14.03 548 2 4
2 3 1022.24 1 12.32 1822 2 2
3 12 1997.04 92 10.56 3124 2 2
4 7 1988.20 22 10.98 3089 2 2
5 13 837.36 40 13.07 1550 2 4
6 8 -0.04 180 13.80 389 2 7

Cycle 297 GMT 18/ 8/2023 7:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 26 14.04 538 2 4
2 3 959.52 -1 14.04 538 2 4
3 12 1115.20 92 9.97 1890 2 2
4 7 1107.68 22 11.09 1917 2 2
5 13 101.16 5 13.91 541 2 5
6 13 72.96 5 13.95 510 2 5
7 13 56.00 5 13.99 490 2 5
8 13 17.16 40 14.01 423 2 5
9 8 0.28 180 13.76 386 2 7

Cycle 296 GMT 8/ 8/2023 13:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 24 14.01 547 2 4
2 10 1031.96 4 13.00 1850 2 3
3 3 948.52 -1 13.00 1850 2 3
4 3 972.32 -1 13.00 1850 2 3
5 12 1134.28 92 10.11 1926 2 2
6 7 1126.88 22 11.23 1931 2 2
7 13 172.32 5 13.83 636 2 5
8 13 104.92 5 13.94 551 2 5
9 13 76.16 5 13.92 515 2 5
10 13 58.32 5 13.97 495 2 5
11 13 16.52 40 14.03 417 2 5
12 8 -0.56 180 13.86 382 2 19

Cycle 295 GMT 29/ 7/2023 19:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 25 14.02 540 2 4
2 3 958.12 -1 14.02 540 2 4
3 12 1122.76 92 10.39 1917 2 2
4 7 1115.28 22 11.40 1923 2 2
5 13 94.88 5 13.92 534 2 5
6 13 67.96 5 13.99 500 2 5
7 13 54.48 5 14.01 488 2 4
8 13 46.80 5 13.98 477 2 5
9 8 0.32 180 13.84 388 2 11

Cycle 294 GMT 20/ 7/2023 1:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 26 13.98 545 2 5
2 3 968.48 -1 13.98 545 2 5
3 3 1022.96 1 12.24 1805 2 2
4 12 1996.48 92 10.59 3118 2 2
5 7 1987.92 22 10.94 3123 2 2
6 13 568.76 40 13.39 1181 2 6
7 8 0.16 180 13.83 386 2 8

Cycle 293 GMT 18/ 7/2023 23:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 24 13.97 558 2 4
2 3 1035.72 1 12.61 1832 2 2
3 12 1095.76 92 10.00 1864 2 2
4 7 1088.28 22 11.13 1888 2 2
5 13 104.12 5 13.91 541 2 5
6 13 74.24 5 13.92 512 2 5
7 8 0.16 180 13.81 390 2 10

Cycle 292 GMT 9/ 7/2023 5:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 25 14.01 558 2 4
2 12 1104.00 92 10.10 1888 2 2
3 7 1096.52 22 11.22 1896 2 2
4 13 160.24 5 13.88 625 2 6
5 13 51.40 5 13.98 483 2 5
6 8 0.28 180 13.82 394 2 10

Cycle 291 GMT 29/ 6/2023 11:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 25 14.02 539 2 4
2 12 1103.64 92 10.32 1894 2 2
3 7 1096.16 22 11.40 1906 2 3
4 13 138.88 5 13.92 587 2 6
5 13 86.00 5 14.02 526 2 6
6 8 -0.12 180 13.83 391 2 11

Cycle 290 GMT 19/ 6/2023 17:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 25 13.97 553 2 4
2 3 1025.12 1 12.36 1829 2 2
3 12 1996.20 92 10.58 3114 2 2
4 7 1987.28 22 10.90 3107 2 2
5 13 662.04 40 13.33 1317 2 6
6 8 0.16 180 13.84 391 2 10

Cycle 289 GMT 18/ 6/2023 15:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 24 14.01 532 2 4
2 12 1104.04 92 9.98 1871 2 2
3 7 1096.64 22 11.12 1890 2 2
4 13 163.28 5 13.84 627 2 5
5 13 98.56 5 13.96 543 2 5
6 8 0.40 180 13.85 387 2 8

Cycle 288 GMT 8/ 6/2023 21:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 25 13.99 533 2 4
2 12 1115.88 92 10.09 1903 2 2
3 7 1108.40 22 11.22 1911 2 2
4 13 152.68 5 13.95 609 2 5
5 13 95.40 5 13.95 541 2 6
6 13 6.48 40 14.03 409 2 5
7 8 -0.04 180 13.82 386 2 10

Cycle 287 GMT 30/ 5/2023 3:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 25 14.02 548 2 4
2 12 1102.00 92 10.31 1889 2 2
3 7 1094.24 22 11.40 1892 2 3
4 13 140.12 5 13.98 595 2 6
5 13 62.20 5 14.02 497 2 5
6 13 50.64 5 14.01 487 2 5
7 8 -0.08 180 13.87 388 2 14

Cycle 286 GMT 20/ 5/2023 9:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 23 13.93 545 2 4
2 10 1002.64 4 13.01 1807 2 4
3 3 953.20 -1 13.01 1807 2 4
4 12 1997.52 92 10.55 3130 2 2
5 7 1989.20 22 10.88 3107 2 2
6 13 701.20 40 13.31 1369 2 5
7 13 16.36 40 14.04 424 2 5
8 8 0.00 180 13.83 390 2 9

Cycle 285 GMT 19/ 5/2023 7:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 24 13.93 547 2 4
2 12 1082.68 92 10.00 1854 2 2
3 7 1075.24 22 11.15 1869 2 2
4 13 141.08 5 13.94 591 2 5
5 13 87.16 5 13.98 530 2 6
6 13 40.72 5 14.00 470 2 5
7 8 0.04 180 13.85 392 2 10

Cycle 284 GMT 9/ 5/2023 13:54: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 25 13.96 555 2 4
2 12 1113.80 92 10.09 1899 2 2
3 7 1106.60 22 11.21 1914 2 2
4 13 164.08 5 13.89 626 2 5
5 13 102.84 5 14.00 557 2 6
6 13 44.96 5 14.03 468 2 5
7 13 42.20 5 14.00 468 2 5
8 13 17.08 40 14.02 426 2 6
9 8 0.32 180 13.87 389 2 13

Cycle 283 GMT 29/ 4/2023 19:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 25 13.98 534 2 4
2 12 1102.32 92 10.25 1886 2 2
3 7 1094.20 22 11.38 1901 2 3
4 13 139.44 5 13.99 604 2 5
5 13 85.36 5 14.00 540 2 5
6 8 -0.04 180 13.86 393 2 9

Cycle 282 GMT 20/ 4/2023 1:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 24 13.93 534 2 5
2 3 973.60 -1 13.93 534 2 5
3 12 1995.16 92 10.49 3107 2 2
4 7 1986.56 22 10.88 3114 2 2
5 13 725.64 40 13.28 1405 2 5
6 13 64.80 5 14.07 488 2 6
7 13 53.04 5 14.01 482 2 6
8 13 47.28 5 14.04 483 2 6
9 13 44.00 5 13.98 476 2 6
10 8 -0.28 180 13.86 390 2 8

Cycle 281 GMT 18/ 4/2023 23:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 23 13.95 534 2 4
2 3 1047.24 2 12.67 1882 2 2
3 12 1120.56 92 9.94 1900 2 2
4 7 1112.92 22 11.17 1911 2 2
5 13 153.20 5 13.93 621 2 5
6 13 94.28 5 13.92 547 2 5
7 13 17.72 40 14.00 425 2 5
8 8 0.08 180 13.81 391 2 11

Cycle 280 GMT 9/ 4/2023 5:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 24 13.99 530 2 3
2 3 1013.64 1 12.39 1804 2 2
3 12 1122.20 92 10.06 1901 2 2
4 7 1115.76 22 11.24 1915 2 3
5 13 98.44 5 13.93 537 2 6
6 13 69.08 5 13.97 503 2 5
7 13 46.08 5 14.02 473 2 5
8 8 0.28 180 13.86 390 2 10

Cycle 279 GMT 30/ 3/2023 11:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 24 13.95 540 2 3
2 12 1101.28 92 10.19 1875 2 2
3 7 1093.24 22 11.35 1896 2 3
4 13 146.56 5 13.97 605 2 5
5 13 49.24 5 14.04 487 2 5
6 13 44.84 5 13.98 476 2 5
7 8 -0.04 180 13.86 393 2 12

Cycle 278 GMT 20/ 3/2023 17:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 23 13.94 542 2 4
2 3 1029.20 1 12.57 1831 2 2
3 12 2001.20 92 10.53 3118 2 2
4 7 1992.40 22 10.92 3113 2 2
5 13 703.36 40 13.32 1371 2 6
6 8 0.08 180 13.85 392 2 13

Cycle 277 GMT 19/ 3/2023 15:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 25 13.91 535 2 4
2 3 971.68 -1 13.91 535 2 4
3 12 1120.52 92 9.95 1899 2 2
4 7 1113.56 22 11.19 1909 2 3
5 13 177.16 5 13.96 642 2 5
6 13 104.56 5 13.97 563 2 6
7 13 70.20 5 13.98 506 2 5
8 13 53.96 5 14.00 491 2 5
9 13 17.20 40 13.98 419 2 7
10 8 -0.24 180 13.80 384 2 13

Cycle 276 GMT 9/ 3/2023 21:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 24 13.94 534 2 4
2 12 1117.60 92 10.07 1898 2 2
3 7 1110.12 22 11.24 1920 2 3
4 13 86.36 40 13.92 512 2 6
5 8 0.60 180 13.84 386 2 11

Cycle 275 GMT 28/ 2/2023 3:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 24 13.96 537 2 3
2 12 1092.52 92 10.19 1878 2 2
3 7 1084.52 22 11.38 1890 2 3
4 13 69.20 40 13.96 483 2 6
5 8 -0.56 180 13.85 386 2 10

Cycle 274 GMT 18/ 2/2023 9:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 25 13.88 535 2 3
2 3 948.80 -1 13.88 535 2 3
3 12 2000.56 92 10.45 3130 2 2
4 7 1991.72 22 10.90 3105 2 2
5 13 701.76 40 13.30 1374 2 5
6 13 14.96 40 14.01 420 2 5
7 8 0.16 180 13.83 388 2 14

Cycle 273 GMT 17/ 2/2023 7:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 25 13.94 534 2 3
2 12 1089.36 92 9.97 1867 2 2
3 7 1081.88 22 11.23 1872 2 2
4 13 134.40 40 13.86 571 2 7
5 8 0.16 180 13.83 387 2 12

Cycle 272 GMT 7/ 2/2023 13:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 23 13.95 545 2 4
2 12 1117.48 92 10.04 1903 2 2
3 7 1110.12 22 11.24 1928 2 2
4 13 156.92 5 13.96 620 2 6
5 13 66.44 5 14.01 507 2 5
6 13 52.12 5 14.00 490 2 5
7 8 -0.32 180 13.85 390 2 11

Cycle 271 GMT 28/ 1/2023 19:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 25 13.94 536 2 3
2 3 969.28 -1 13.94 536 2 3
3 12 1111.16 92 10.10 1889 2 2
4 7 1103.84 22 11.37 1908 2 3
5 13 170.84 5 13.98 636 2 5
6 13 67.84 5 14.05 501 2 5
7 13 16.68 40 14.00 427 2 5
8 8 0.08 180 13.84 389 2 12

Cycle 270 GMT 19/ 1/2023 1:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 24 13.96 540 2 3
2 3 1040.04 1 12.61 1846 2 2
3 12 1997.52 92 10.50 3120 2 2
4 7 1989.00 22 10.92 3092 2 2
5 13 825.12 40 13.17 1548 2 4
6 8 0.36 180 13.88 389 2 7

Cycle 269 GMT 17/ 1/2023 23:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 25 13.92 527 2 3
2 12 1097.52 92 10.00 1872 2 2
3 7 1090.08 22 11.23 1897 2 2
4 13 98.08 5 13.96 531 2 5
5 13 69.52 5 13.99 502 2 5
6 13 55.84 5 13.98 492 2 5
7 13 47.88 5 14.01 481 2 5
8 8 -0.16 180 13.87 384 2 16

Cycle 268 GMT 8/ 1/2023 6: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 25 13.91 534 2 3
2 12 1137.52 92 10.05 1918 2 2
3 7 1130.44 22 11.23 1943 2 2
4 13 211.20 5 13.91 698 2 5
5 13 124.80 5 13.97 575 2 6
6 13 82.28 5 13.97 522 2 5
7 8 0.08 180 13.87 385 2 6

Cycle 267 GMT 29/12/2022 11:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 24 13.94 537 2 4
2 3 1029.96 1 12.68 1835 2 2
3 12 1123.40 92 10.10 1903 2 2
4 7 1116.20 22 11.35 1929 2 3
5 13 154.48 5 13.97 606 2 5
6 13 92.60 5 13.98 532 2 5
7 13 64.48 5 13.98 492 2 5
8 8 0.08 180 13.87 384 2 17

Cycle 266 GMT 19/12/2022 17:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 25 13.86 537 2 4
2 3 961.92 -1 13.86 537 2 4
3 12 2000.48 92 10.46 3123 2 2
4 7 1991.56 22 10.86 3109 2 2
5 13 849.36 40 13.16 1568 2 4
6 8 0.08 180 13.85 390 2 10

Cycle 265 GMT 18/12/2022 15:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 26 13.81 552 2 4
2 3 957.00 -1 13.81 552 2 4
3 3 1013.96 1 12.32 1814 2 2
4 12 1098.04 92 9.99 1866 2 2
5 7 1091.00 22 11.26 1890 2 2
6 13 156.04 5 13.93 610 2 5
7 13 107.12 5 13.92 553 2 5
8 13 72.92 5 13.94 514 2 5
9 8 0.24 180 13.84 391 2 10

Cycle 264 GMT 8/12/2022 21:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 25 13.92 543 2 3
2 3 940.44 -1 13.92 543 2 3
3 12 1142.80 92 10.06 1927 2 2
4 7 1136.44 22 11.27 1954 2 2
5 13 141.20 5 13.95 604 2 6
6 13 93.32 5 13.97 541 2 5
7 13 66.44 5 13.96 507 2 5
8 8 -0.16 180 13.84 392 2 9

Cycle 263 GMT 29/11/2022 3:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 25 13.86 535 2 5
2 12 1068.80 92 10.19 1834 2 2
3 7 1060.28 22 11.43 1859 2 3
4 13 127.84 5 13.95 580 2 5
5 13 84.76 5 13.96 535 2 5
6 13 40.08 5 14.01 476 2 5
7 13 4.76 40 13.98 413 2 4
8 8 0.08 180 13.80 390 2 7

Cycle 262 GMT 19/11/2022 9:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 25 13.90 542 2 4
2 12 1998.12 92 10.48 3111 2 2
3 7 1990.40 22 10.90 3097 2 2
4 13 587.92 40 13.41 1207 2 6
5 8 0.16 180 13.87 385 2 9

Cycle 261 GMT 18/11/2022 7:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 25 13.89 543 2 3
2 3 1021.20 1 12.51 1798 2 2
3 12 1100.40 92 9.98 1860 2 2
4 7 1092.80 22 11.32 1881 2 2
5 13 176.48 5 13.88 648 2 5
6 13 69.00 5 13.97 501 2 4
7 13 47.60 5 14.00 477 2 4
8 13 44.60 5 13.98 482 2 4
9 13 41.32 5 13.96 471 2 4
10 8 -0.08 180 13.82 389 2 12

Cycle 260 GMT 8/11/2022 13:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 24 13.92 540 2 4
2 10 1012.04 4 13.07 1825 2 3
3 3 936.92 -1 13.07 1825 2 3
4 12 1093.08 92 10.14 1860 2 2
5 7 1086.28 22 11.34 1880 2 2
6 13 299.64 8 13.82 826 2 6
7 13 48.96 5 14.01 472 2 5
8 8 0.36 180 13.86 386 2 8

Cycle 259 GMT 29/10/2022 19:48:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 25 13.88 548 2 4
2 3 967.64 -1 13.88 548 2 4
3 12 1125.40 92 10.10 1895 2 2
4 7 1117.76 22 11.39 1929 2 3
5 13 321.92 9 13.83 842 2 5
6 13 68.36 5 14.02 496 2 5
7 13 53.04 5 14.02 486 2 5
8 8 -0.08 180 13.88 386 2 9

Cycle 258 GMT 20/10/2022 1:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 25 13.86 536 2 4
2 12 2000.92 92 10.40 3111 2 2
3 7 1993.16 22 10.89 3117 2 2
4 13 572.64 40 13.42 1195 2 5
5 13 48.32 5 14.04 467 2 5
6 13 44.12 5 13.98 474 2 5
7 8 0.04 180 13.85 388 2 15

Cycle 257 GMT 18/10/2022 23:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 25 13.85 549 2 4
2 12 1070.88 92 10.05 1838 2 2
3 7 1062.96 22 11.33 1860 2 3
4 13 90.60 5 13.97 533 2 6
5 13 68.16 5 13.93 505 2 5
6 13 54.96 5 13.98 490 2 5
7 13 16.44 40 13.94 422 2 4
8 8 0.20 180 13.77 390 2 12

Cycle 256 GMT 9/10/2022 5:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 25 13.88 556 2 4
2 12 1120.72 92 10.10 1899 2 2
3 7 1113.32 22 11.31 1935 2 3
4 13 168.60 5 13.90 633 2 5
5 13 66.48 5 13.98 502 2 5
6 13 46.08 5 13.99 482 2 5
7 8 0.00 180 13.86 388 2 10

Cycle 255 GMT 29/ 9/2022 11:37: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 25 13.87 548 2 4
2 12 1109.52 92 10.08 1895 2 2
3 7 1101.68 22 11.43 1910 2 2
4 13 167.36 5 13.94 632 2 5
5 13 102.08 5 13.98 548 2 5
6 8 -0.04 180 13.86 387 2 11

Cycle 254 GMT 19/ 9/2022 17:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 25 13.81 540 2 5
2 12 2001.00 92 10.37 3116 2 2
3 7 1992.44 22 10.89 3112 2 2
4 13 580.72 40 13.40 1195 2 5
5 8 0.20 180 13.83 392 2 10

Cycle 253 GMT 18/ 9/2022 15:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 25 13.83 536 2 5
2 12 1092.56 92 10.03 1864 2 2
3 7 1084.88 22 11.35 1875 2 2
4 13 286.76 8 13.79 793 2 5
5 13 86.56 5 13.91 523 2 5
6 13 62.28 5 13.94 497 2 5
7 13 16.92 40 13.93 423 2 6
8 8 -0.04 180 13.77 385 2 14

Cycle 252 GMT 8/ 9/2022 21:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 25 13.86 537 2 4
2 12 1108.00 92 10.05 1883 2 2
3 7 1100.64 22 11.33 1898 2 3
4 13 170.36 5 13.92 629 2 6
5 13 67.16 5 13.92 502 2 5
6 13 54.12 5 13.99 483 2 5
7 13 46.92 5 13.96 482 2 5
8 8 0.20 180 13.83 392 2 14

Cycle 251 GMT 30/ 8/2022 3:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 25 13.83 549 2 4
2 12 1085.92 92 10.13 1859 2 2
3 7 1078.88 22 11.46 1878 2 3
4 13 478.72 40 13.50 1055 2 6
5 8 0.20 180 13.83 387 2 6

Cycle 250 GMT 20/ 8/2022 9:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 25 13.84 542 2 4
2 12 1997.12 92 10.30 3106 2 2
3 7 1988.88 22 10.87 3096 2 2
4 13 587.64 40 13.39 1205 2 5
5 8 0.28 180 13.84 388 2 7

Cycle 249 GMT 19/ 8/2022 7:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 25 13.87 544 2 4
2 12 1083.68 92 10.08 1838 2 2
3 7 1076.16 22 11.38 1874 2 3
4 13 146.88 5 13.85 606 2 6
5 13 92.12 5 13.91 531 2 6
6 13 7.88 40 13.95 405 2 4
7 8 -0.56 180 13.78 382 2 14

Cycle 248 GMT 9/ 8/2022 13:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 25 13.86 543 2 4
2 12 1088.44 92 10.18 1857 2 2
3 7 1081.28 22 11.41 1878 2 3
4 13 141.56 40 13.82 584 2 6
5 8 0.48 180 13.81 388 2 11

Cycle 247 GMT 30/ 7/2022 19:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 24 13.84 546 2 4
2 3 1016.76 1 12.56 1790 2 2
3 12 1101.64 92 10.10 1862 2 2
4 7 1093.92 22 11.47 1892 2 3
5 13 287.20 40 13.69 778 2 6
6 8 0.08 180 13.84 384 2 11

Cycle 246 GMT 21/ 7/2022 2: 6: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 25 13.83 532 2 3
2 12 2002.76 92 10.43 3106 2 2
3 7 1994.56 22 10.97 3097 2 2
4 13 717.48 40 13.25 1400 2 5
5 8 -0.12 180 13.86 385 2 10

Cycle 245 GMT 19/ 7/2022 23:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 23 13.85 534 2 3
2 3 1039.36 1 12.71 1854 2 2
3 12 1130.84 92 9.91 1902 2 2
4 7 1123.88 23 11.36 1925 2 2
5 13 192.72 40 13.76 650 2 6
6 8 -0.12 180 13.83 380 2 13

Cycle 244 GMT 10/ 7/2022 5:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 24 13.84 536 2 3
2 10 1000.16 4 13.12 1826 2 3
3 3 915.76 -2 13.12 1826 2 3
4 12 1065.76 92 10.12 1823 2 2
5 7 1058.80 22 11.44 1856 2 2
6 13 144.28 40 13.81 584 2 6
7 8 0.36 180 13.84 380 2 6

Cycle 243 GMT 30/ 6/2022 12:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 24 13.81 551 2 3
2 12 1118.80 92 10.08 1885 2 2
3 7 1111.48 22 11.48 1913 2 2
4 13 320.20 40 13.67 822 2 6
5 8 -0.28 180 13.88 378 2 10

Cycle 242 GMT 20/ 6/2022 18:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 25 13.85 535 2 3
2 12 1994.92 92 10.45 3097 2 2
3 7 1986.28 22 10.97 3078 2 2
4 13 707.48 40 13.27 1380 2 4
5 13 18.00 40 13.97 412 2 8
6 8 0.04 180 13.87 381 2 16

Cycle 241 GMT 19/ 6/2022 16:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 27 13.93 507 2 2
2 3 920.36 -2 13.93 507 2 2
3 12 1083.64 92 9.99 1842 2 2
4 7 1077.08 22 11.44 1866 2 2
5 13 93.48 40 13.86 510 2 6
6 8 -0.08 180 13.86 375 2 12

Cycle 240 GMT 9/ 6/2022 22:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 26 13.90 518 2 2
2 3 965.84 -1 13.90 518 2 2
3 12 1110.48 92 10.08 1882 2 2
4 7 1103.72 22 11.47 1901 2 2
5 13 189.40 40 13.77 649 2 6
6 8 -0.08 180 13.91 367 2 13

Cycle 239 GMT 31/ 5/2022 4:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 26 13.94 516 2 2
2 12 1093.12 92 10.20 1850 2 2
3 7 1085.52 22 11.56 1876 2 2
4 13 168.16 40 13.82 609 2 6
5 8 -0.04 180 13.94 367 2 12

Cycle 238 GMT 21/ 5/2022 10:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 26 13.90 525 2 2
2 3 968.20 -1 13.90 525 2 2
3 12 2000.28 92 10.41 3111 2 2
4 7 1991.64 22 11.03 3094 2 2
5 13 724.40 40 13.26 1411 2 4
6 13 1.96 40 14.07 375 2 11
7 8 -0.12 180 14.01 362 2 16

Cycle 237 GMT 20/ 5/2022 8:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 25 14.02 491 2 2
2 3 1034.36 1 12.76 1828 2 2
3 3 1013.84 1 12.14 1819 2 2
4 12 1094.80 92 9.97 1855 2 2
5 7 1087.68 22 11.45 1886 2 2
6 13 197.76 40 13.75 667 2 7
7 8 -0.20 180 13.93 366 2 15

Cycle 236 GMT 10/ 5/2022 14:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 26 13.95 502 2 2
2 12 1152.12 92 10.12 1927 2 2
3 7 1145.36 22 11.47 1955 2 2
4 13 61.88 40 13.99 442 2 6
5 8 0.20 180 14.03 357 2 14

Cycle 235 GMT 30/ 4/2022 20:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 25 13.96 503 2 2
2 3 1027.88 1 12.73 1830 2 2
3 12 1121.92 92 10.21 1878 2 2
4 7 1115.04 22 11.52 1915 2 3
5 13 175.20 40 13.81 615 2 6
6 8 -0.20 180 13.93 364 2 14

Cycle 234 GMT 21/ 4/2022 2:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 25 13.90 501 2 2
2 3 1040.72 1 12.80 1843 2 2
3 12 1994.88 92 10.51 3077 2 2
4 7 1986.64 22 11.09 3061 2 2
5 13 750.24 40 13.21 1442 2 4
6 8 0.00 180 13.99 361 2 15

Cycle 233 GMT 20/ 4/2022 0:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 25 13.87 515 2 2
2 12 1143.00 92 10.02 1896 2 2
3 7 1136.48 22 11.44 1942 2 3
4 13 250.16 40 13.70 734 2 5
5 8 -0.28 180 13.94 352 2 13

Cycle 232 GMT 10/ 4/2022 6:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 25 13.93 516 2 2
2 12 1140.36 92 10.06 1924 2 2
3 7 1133.36 22 11.48 1942 2 2
4 13 109.96 40 13.86 530 2 7
5 8 -0.08 180 13.92 369 2 14

Cycle 231 GMT 31/ 3/2022 12:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 25 13.83 517 2 2
2 12 1107.32 92 10.23 1864 2 2
3 7 1100.16 22 11.59 1889 2 2
4 13 99.96 40 13.86 522 2 6
5 8 -0.44 180 13.92 371 2 14

Cycle 230 GMT 21/ 3/2022 18:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 25 13.94 504 2 2
2 12 1995.44 92 10.52 3091 2 2
3 7 1986.84 22 11.09 3077 2 2
4 13 721.80 40 13.26 1399 2 4
5 13 19.00 40 13.99 407 2 8
6 8 -0.16 180 13.94 375 2 14

Cycle 229 GMT 20/ 3/2022 16:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 23 13.94 505 2 2
2 3 1057.60 2 12.87 1865 2 2
3 12 1135.04 92 9.97 1904 2 2
4 7 1127.68 22 11.45 1941 2 2
5 13 224.36 40 13.71 692 2 6
6 8 0.04 180 13.91 368 2 15

Cycle 228 GMT 10/ 3/2022 22:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 24 13.87 516 2 2
2 3 1026.24 1 12.77 1814 2 2
3 12 1132.64 92 10.14 1901 2 2
4 7 1125.12 22 11.49 1929 2 2
5 13 335.24 40 13.61 847 2 5
6 8 -0.12 180 13.89 373 2 12

Cycle 227 GMT 1/ 3/2022 5: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 25 13.93 507 2 2
2 3 952.48 -1 13.93 507 2 2
3 12 1103.08 92 10.22 1871 2 2
4 7 1095.60 22 11.59 1893 2 2
5 13 154.28 40 13.80 596 2 6
6 8 -0.24 180 13.90 376 2 18

Cycle 226 GMT 19/ 2/2022 11:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 25 13.85 517 2 2
2 12 1997.72 92 10.55 3091 2 2
3 7 1989.48 22 11.11 3061 2 2
4 13 621.48 40 13.34 1271 2 5
5 13 21.80 40 13.98 414 2 7
6 8 -0.28 180 13.95 377 2 9

Cycle 225 GMT 18/ 2/2022 8:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 25 13.93 510 2 2
2 3 973.64 -1 13.93 510 2 2
3 12 1130.76 92 9.99 1905 2 2
4 7 1123.68 22 11.48 1933 2 2
5 13 341.48 40 13.60 851 2 5
6 8 0.00 180 13.90 369 2 10

Cycle 224 GMT 8/ 2/2022 15:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 23 13.89 513 2 2
2 3 1053.20 2 12.88 1836 2 2
3 3 1015.36 1 12.19 1838 2 2
4 12 1117.72 72 10.13 1887 2 2
5 7 1112.68 22 11.65 1915 2 2
6 13 557.44 40 13.38 1165 2 5
7 8 0.04 180 13.91 369 2 14

Cycle 223 GMT 29/ 1/2022 21:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 25 13.94 511 2 2
2 3 970.40 -1 13.94 511 2 2
3 12 1134.64 72 10.30 1905 2 2
4 7 1128.88 22 11.69 1944 2 2
5 13 557.96 40 13.41 1162 2 5
6 8 -0.52 180 13.93 368 2 9

Cycle 222 GMT 20/ 1/2022 3:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 24 13.86 518 2 2
2 3 1023.44 1 12.58 1816 2 2
3 12 1998.52 72 10.69 3094 2 2
4 7 1990.76 22 11.14 3096 2 2
5 13 955.72 40 13.02 1725 2 3
6 13 25.24 40 13.98 417 2 7
7 8 -0.20 180 13.97 371 2 14

Cycle 221 GMT 19/ 1/2022 1: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 25 13.93 503 2 2
2 12 1083.24 72 10.15 1837 2 2
3 7 1077.92 22 11.64 1876 2 2
4 13 640.68 40 13.29 1289 2 5
5 8 -0.08 180 13.89 373 2 11

Cycle 220 GMT 9/ 1/2022 7:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 20 13.92 508 2 2
2 10 1034.56 4 13.19 1838 2 2
3 3 1018.20 1 12.47 1802 2 2
4 12 1154.04 72 10.06 1934 2 2
5 7 1149.56 22 11.67 1961 2 2
6 13 591.36 40 13.36 1215 2 5
7 13 20.04 40 13.98 407 2 6
8 8 -0.08 180 13.94 368 2 13

Cycle 219 GMT 30/12/2021 13:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 29 13.93 512 2 3
2 3 809.52 -4 13.93 512 2 3
3 3 942.88 -1 13.93 512 2 3
4 12 1114.88 72 10.37 1886 2 2
5 7 1109.20 22 11.74 1925 2 2
6 13 411.84 40 13.55 952 2 5
7 13 11.92 40 13.97 402 2 7
8 8 -0.44 180 13.88 376 2 18

Cycle 218 GMT 20/12/2021 19:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 22 13.89 510 2 2
2 3 1039.64 1 12.88 1840 2 2
3 12 1999.84 72 10.73 3108 2 2
4 7 1992.28 22 11.16 3083 2 2
5 13 943.24 40 13.04 1718 2 3
6 13 28.60 40 13.97 425 2 6
7 8 -0.12 180 13.94 375 2 12

Cycle 217 GMT 19/12/2021 17: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 25 13.83 529 2 2
2 12 1086.88 72 10.17 1838 2 2
3 7 1081.08 22 11.70 1873 2 2
4 13 507.80 40 13.41 1100 2 5
5 13 8.64 40 13.97 391 2 6
6 8 -0.40 180 13.88 372 2 23

Cycle 216 GMT 9/12/2021 23:14: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 24 14.09 473 2 2
2 10 1032.76 5 13.01 1849 2 2
3 12 1021.12 72 10.49 1762 2 2
4 7 1017.28 22 11.82 1800 2 3
5 13 438.32 40 13.49 1002 2 5
6 8 -0.28 180 13.88 377 2 15

Cycle 215 GMT 30/11/2021 5:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 24 13.84 535 2 3
2 7 1101.72 23 11.67 1885 3 2
3 13 999.48 40 12.94 1784 2 3
4 13 111.80 40 14.02 495 2 4
5 8 0.00 180 14.16 341 2 12

Cycle 214 GMT 25/11/2021 20:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 26 13.84 526 2 3
2 3 914.92 -2 13.84 526 2 3
3 12 1997.28 72 10.82 3105 2 2
4 7 1989.64 22 11.16 3082 2 2
5 13 1061.28 40 12.94 1858 2 3
6 13 53.52 40 13.94 457 2 6
7 8 0.00 180 13.91 382 2 13

Cycle 213 GMT 24/11/2021 18:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 25 13.84 538 2 3
2 12 1099.08 72 10.19 1860 2 2
3 7 1094.08 22 11.63 1906 2 2
4 13 519.28 40 13.41 1096 2 5
5 13 27.96 40 13.94 405 2 6
6 8 -0.24 180 13.89 361 2 10

Cycle 212 GMT 15/11/2021 0:22: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 23 13.84 551 2 3
2 10 1010.44 5 13.12 1820 2 3
3 3 904.44 -2 13.12 1820 2 3
4 12 1060.40 72 10.30 1798 2 2
5 7 1054.60 22 11.71 1844 2 3
6 13 475.84 40 13.44 1057 2 5
7 8 -0.16 180 13.84 384 2 7

Cycle 211 GMT 5/11/2021 6:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 25 13.86 523 2 3
2 3 966.88 -1 13.86 523 2 3
3 12 1111.24 72 10.48 1893 2 2
4 7 1102.60 22 11.77 1904 2 3
5 13 496.04 40 13.46 1076 2 5
6 8 0.12 180 13.87 379 2 11

Cycle 210 GMT 26/10/2021 13: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 25 13.87 535 2 3
2 3 1042.52 1 12.81 1850 2 2
3 12 1699.00 72 11.19 2710 2 2
4 7 1693.04 22 11.43 2707 2 2
5 13 1608.76 40 12.42 2599 2 2
6 13 30.40 40 13.97 425 2 6
7 8 0.00 180 13.92 374 2 13

Cycle 209 GMT 25/10/2021 9:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 23 13.85 532 2 4
2 3 1025.56 1 12.81 1821 2 2
3 12 1161.44 72 10.14 1942 2 2
4 7 1155.84 22 11.67 1977 2 2
5 13 604.84 40 13.34 1227 2 4
6 8 -0.08 180 13.89 372 2 13

Cycle 208 GMT 15/10/2021 15:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 25 13.83 545 2 4
2 12 1109.32 72 10.34 1882 2 2
3 7 1103.24 22 11.69 1914 2 2
4 13 530.36 40 13.40 1131 2 5
5 8 -0.08 180 13.83 383 2 9

Cycle 207 GMT 5/10/2021 21:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 25 13.85 540 2 4
2 12 1133.88 68 10.45 1914 2 2
3 7 1128.80 22 11.76 1949 2 2
4 13 675.76 38 13.30 1330 2 5
5 8 0.04 180 13.83 385 2 10

Cycle 206 GMT 26/ 9/2021 4: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 26 13.81 540 2 3
2 3 936.08 -1 13.81 540 2 3
3 12 1088.60 1 12.00 1866 2 2
4 12 1890.52 68 10.95 2971 2 2
5 7 1883.04 22 11.26 2968 2 2
6 13 782.72 38 13.19 1488 2 4
7 8 -0.04 180 13.84 389 2 11

Cycle 205 GMT 25/ 9/2021 0:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 27 13.82 521 2 3
2 3 923.76 -1 13.82 521 2 3
3 3 959.28 -1 13.82 521 2 3
4 12 1128.24 68 10.13 1914 2 2
5 7 1123.16 22 11.69 1926 2 2
6 13 697.72 38 13.24 1364 2 4
7 13 16.60 38 13.93 411 2 5
8 8 0.12 180 13.81 379 2 16

Cycle 204 GMT 15/ 9/2021 6:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 25 13.82 531 2 4
2 12 1100.32 68 10.27 1863 2 2
3 7 1095.28 22 11.71 1905 2 2
4 13 654.00 38 13.27 1305 2 5
5 8 -0.24 180 13.82 381 2 13

Cycle 203 GMT 5/ 9/2021 12:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 27 13.85 541 2 3
2 3 973.52 -1 13.85 541 2 3
3 12 1062.08 68 10.52 1823 2 2
4 7 1056.48 22 11.83 1854 2 3
5 13 476.08 38 13.47 1048 2 5
6 8 0.20 180 13.82 384 2 8

Cycle 202 GMT 26/ 8/2021 18:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 26 13.84 537 2 3
2 12 1080.96 1 11.69 1880 2 2
3 12 1877.32 68 10.89 2944 2 2
4 7 1867.16 22 11.29 2931 2 2
5 13 1027.80 38 12.98 1831 2 4
6 8 0.12 180 13.90 384 2 8

Cycle 201 GMT 25/ 8/2021 15:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 26 13.82 539 2 3
2 12 1126.28 68 10.14 1888 2 2
3 7 1122.36 22 11.73 1930 2 2
4 13 704.32 38 13.22 1382 2 4
5 8 -0.08 180 13.86 382 2 11

Cycle 200 GMT 15/ 8/2021 21:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 13.84 536 2 3
2 10 1008.32 4 13.06 1819 2 3
3 3 920.52 -2 13.06 1819 2 3
4 12 1082.04 68 10.34 1834 2 2
5 7 1077.00 22 11.75 1878 2 3
6 13 547.48 38 13.40 1159 2 4
7 8 0.24 180 13.87 382 2 9

Cycle 199 GMT 6/ 8/2021 3:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 26 13.86 545 2 3
2 12 1117.12 68 10.46 1892 2 2
3 7 1111.40 22 11.84 1921 2 3
4 13 661.88 38 13.32 1310 2 4
5 8 -0.16 180 13.91 371 2 8

Cycle 198 GMT 27/ 7/2021 9:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 26 13.82 541 2 3
2 12 1113.32 1 11.90 1907 2 2
3 12 1963.36 68 10.80 3063 2 2
4 7 1956.24 22 11.31 3049 2 2
5 13 1028.40 38 12.98 1831 2 3
6 13 16.28 38 14.01 406 2 5
7 8 0.08 180 13.91 375 2 10

Cycle 197 GMT 26/ 7/2021 5:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 26 13.87 516 2 3
2 12 1117.40 68 10.19 1879 2 2
3 7 1112.00 22 11.76 1916 2 2
4 13 547.40 38 13.39 1149 2 5
5 8 0.00 180 13.88 371 2 8

Cycle 196 GMT 16/ 7/2021 11:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 26 13.79 537 2 4
2 12 1117.88 68 10.30 1887 2 2
3 7 1112.96 22 11.75 1919 2 2
4 13 671.20 38 13.27 1339 2 4
5 8 0.24 180 13.89 377 2 16

Cycle 195 GMT 6/ 7/2021 18: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 26 13.85 538 2 3
2 12 1120.72 68 10.56 1903 2 2
3 7 1115.00 22 11.87 1913 2 2
4 13 510.88 38 13.46 1097 2 5
5 8 -0.24 180 13.89 373 2 12

Cycle 194 GMT 27/ 6/2021 0:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 26 13.83 542 2 3
2 12 2001.96 68 10.95 3110 2 2
3 7 1994.68 22 11.31 3102 2 2
4 13 1121.48 38 12.90 1948 2 3
5 13 82.92 38 13.91 497 2 6
6 8 0.16 180 13.91 377 2 8

Cycle 193 GMT 25/ 6/2021 22: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 26 13.86 540 2 3
2 12 1120.92 68 10.11 1886 2 2
3 7 1116.96 22 11.69 1927 2 2
4 13 702.48 38 13.19 1382 2 4
5 8 -0.16 180 13.86 376 2 11

Cycle 192 GMT 16/ 6/2021 4: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 26 13.89 539 2 3
2 12 1120.44 68 10.22 1888 2 2
3 7 1115.88 22 11.73 1924 2 2
4 13 703.44 38 13.25 1375 2 4
5 8 0.28 180 13.87 377 2 13

Cycle 191 GMT 6/ 6/2021 10:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 26 13.88 528 2 3
2 12 1105.52 68 10.52 1890 2 2
3 7 1100.36 22 11.77 1920 2 3
4 13 526.60 38 13.44 1130 2 5
5 8 0.28 180 13.86 382 2 10

Cycle 190 GMT 27/ 5/2021 16:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 18 13.93 539 2 3
2 10 1045.80 4 13.30 1852 2 3
3 10 1078.68 3 13.34 1933 2 3
4 3 1054.84 1 12.97 1870 2 2
5 3 1020.80 1 12.42 1837 2 2
6 12 1129.32 5 12.87 1967 2 2
7 12 1812.92 68 11.38 2866 2 2
8 7 1804.84 22 11.51 2865 2 2
9 13 546.32 38 13.45 1159 2 5
10 8 0.12 180 13.92 381 2 12

Cycle 189 GMT 26/ 5/2021 12:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 26 13.85 551 2 3
2 12 2006.88 68 9.06 3015 2 2
3 7 2001.12 22 11.07 3095 2 2
4 13 1583.12 38 12.41 2572 2 2
5 13 521.64 38 13.44 1129 2 5
6 8 -0.36 180 13.90 384 2 11

Cycle 188 GMT 16/ 5/2021 13:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 26 13.90 534 2 3
2 12 2000.48 68 8.96 3004 2 2
3 7 1994.96 22 11.07 3103 2 2
4 13 1577.88 38 12.43 2560 2 3
5 13 510.76 38 13.46 1102 2 5
6 8 0.20 180 13.91 379 2 13

Cycle 187 GMT 6/ 5/2021 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 26 13.90 529 2 3
2 12 1999.64 68 8.98 3007 2 2
3 7 1993.80 22 11.10 3103 2 2
4 13 1561.08 38 12.44 2545 2 2
5 13 630.92 38 13.34 1285 2 4
6 8 0.12 180 13.91 382 2 8

Cycle 186 GMT 26/ 4/2021 15:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 26 13.91 536 2 4
2 12 2000.84 68 9.03 3015 2 2
3 7 1995.24 22 11.05 3111 2 2
4 13 1571.68 38 12.44 2546 2 2
5 13 648.80 38 13.33 1302 2 5
6 8 0.20 180 13.92 381 2 12

Cycle 185 GMT 16/ 4/2021 16:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 26 13.86 542 2 4
2 12 2003.36 68 8.97 3000 2 2
3 7 1997.12 22 11.11 3098 2 2
4 13 1457.40 38 12.59 2398 2 3
5 13 390.12 38 13.58 922 2 5
6 8 -0.24 180 13.92 379 2 14

Cycle 184 GMT 6/ 4/2021 17: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 25 13.92 536 2 3
2 3 1035.16 1 13.00 1826 2 2
3 12 2000.60 68 9.05 2999 2 2
4 7 1994.88 22 11.15 3101 2 2
5 13 1560.28 38 12.47 2549 2 2
6 13 640.36 38 13.34 1294 2 5
7 8 0.08 180 13.91 385 2 12

Cycle 183 GMT 27/ 3/2021 18:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 26 13.90 536 2 3
2 3 962.96 -1 13.90 536 2 3
3 12 2005.20 68 9.03 3002 2 2
4 7 2000.12 22 11.12 3101 2 2
5 13 1566.28 38 12.46 2543 2 2
6 13 491.24 38 13.48 1074 2 5
7 8 0.00 180 13.92 380 2 12

Cycle 182 GMT 17/ 3/2021 19:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 26 13.94 533 2 3
2 12 2000.32 68 9.09 3011 2 2
3 7 1994.52 22 11.14 3102 2 2
4 13 1571.56 38 12.44 2561 2 2
5 13 641.04 38 13.34 1290 2 4
6 8 0.20 180 13.92 384 2 14

Cycle 181 GMT 7/ 3/2021 20: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 25 13.94 531 2 3
2 3 1018.84 1 12.67 1823 2 2
3 12 2008.12 68 9.04 3017 2 2
4 7 2002.40 22 11.13 3131 2 2
5 13 1449.76 38 12.57 2397 2 3
6 13 542.04 38 13.44 1148 2 5
7 8 -0.12 180 13.93 379 2 12

Cycle 180 GMT 25/ 2/2021 21: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 13.93 537 2 3
2 3 953.76 -1 13.93 537 2 3
3 12 2005.44 68 8.88 3013 2 2
4 7 2000.00 22 11.19 3078 2 2
5 13 1585.40 38 12.46 2566 2 2
6 13 646.88 38 13.35 1292 2 5
7 8 -0.12 180 13.93 378 2 17

Cycle 179 GMT 15/ 2/2021 21:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 27 13.94 531 2 3
2 12 2000.72 68 9.10 3020 2 2
3 7 1994.36 22 11.14 3099 2 2
4 13 1562.64 38 12.46 2541 2 2
5 13 644.40 38 13.34 1291 2 5
6 8 0.04 180 13.93 380 2 13

Cycle 178 GMT 5/ 2/2021 22:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 26 13.94 543 2 3
2 12 2007.48 61 9.03 2997 2 2
3 7 2002.20 22 11.17 3111 2 2
4 13 1589.28 38 12.45 2578 2 3
5 13 545.52 38 13.45 1151 2 5
6 8 0.08 180 13.93 384 2 10

Cycle 177 GMT 26/ 1/2021 23:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 26 13.96 526 2 3
2 12 2008.64 61 9.01 3001 2 2
3 7 2002.80 22 11.19 3120 2 2
4 13 1733.52 38 12.30 2774 2 2
5 13 799.48 38 13.20 1518 2 4
6 8 -0.28 180 13.93 380 2 13

Cycle 176 GMT 17/ 1/2021 0: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 25 13.95 535 2 3
2 12 2000.12 61 9.01 2997 2 2
3 7 1994.88 22 11.24 3086 2 2
4 13 1599.80 38 12.47 2590 2 2
5 13 695.36 38 13.31 1370 2 4
6 8 0.04 180 13.93 381 2 10

Cycle 175 GMT 7/ 1/2021 1: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 26 13.91 536 2 3
2 3 973.00 -1 13.91 536 2 3
3 12 2001.44 61 9.00 3014 2 2
4 7 1996.36 22 11.19 3111 2 2
5 13 1731.48 38 12.30 2784 2 2
6 13 683.56 38 13.32 1356 2 4
7 8 -0.08 180 13.92 383 2 12

Cycle 174 GMT 28/12/2020 2: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 26 13.96 535 2 3
2 12 2000.68 61 9.01 2995 2 2
3 7 1996.04 22 11.19 3121 2 2
4 13 1592.40 38 12.44 2585 2 2
5 13 680.08 38 13.31 1342 2 4
6 8 0.16 180 13.93 380 2 14

Cycle 173 GMT 18/12/2020 2:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 26 13.96 533 2 3
2 12 2000.76 61 9.04 2988 2 2
3 7 1995.64 22 11.23 3117 2 2
4 13 1589.68 38 12.48 2576 2 2
5 13 548.88 38 13.46 1157 2 5
6 8 -0.16 180 13.92 382 2 11

Cycle 172 GMT 8/12/2020 3:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 26 13.91 543 2 4
2 12 2006.80 61 9.13 3034 2 2
3 7 2001.20 22 11.18 3109 2 2
4 13 1596.40 38 12.43 2597 2 2
5 13 684.36 38 13.32 1354 2 4
6 8 0.16 180 13.93 381 2 18

Cycle 171 GMT 28/11/2020 4:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 26 13.96 527 2 3
2 12 2004.64 61 8.94 2985 2 2
3 7 1999.20 22 11.19 3137 2 2
4 13 1734.88 38 12.31 2775 2 2
5 13 651.16 38 13.35 1304 2 4
6 8 -0.16 180 13.93 382 2 11

Cycle 170 GMT 18/11/2020 5:34: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 27 13.88 556 2 3
2 3 960.56 -1 13.88 556 2 3
3 12 2000.52 61 8.87 2961 2 2
4 7 1995.08 23 11.27 3110 2 2
5 13 1735.80 38 12.32 2776 2 2
6 13 763.72 38 13.25 1472 2 4
7 8 0.00 180 13.93 382 2 10

Cycle 169 GMT 8/11/2020 6:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 17 13.99 534 2 3
2 10 1001.28 6 13.34 1816 2 3
3 10 1037.52 3 13.40 1869 2 3
4 3 1024.68 1 12.74 1816 2 2
5 12 2003.28 61 8.81 2953 2 2
6 7 1998.04 22 11.26 3119 2 2
7 13 1728.04 38 12.35 2770 2 2
8 13 803.48 38 13.21 1527 2 4
9 8 0.16 180 13.93 386 2 9

Cycle 168 GMT 29/10/2020 7:42:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 26 13.92 548 2 3
2 3 868.24 -3 13.92 548 2 3
3 3 788.04 -4 13.92 548 2 3
4 12 2001.44 61 8.74 2945 2 2
5 7 1996.40 22 11.23 3115 2 2
6 13 1720.92 38 12.34 2767 2 2
7 13 773.56 38 13.23 1484 2 4
8 8 0.28 180 13.92 384 2 10

Cycle 167 GMT 19/10/2020 9: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 26 14.00 543 2 3
2 12 1331.76 61 9.90 2159 2 2
3 7 1326.28 22 11.69 2217 2 2
4 13 1206.88 38 12.70 2064 2 3
5 13 668.24 38 13.28 1330 2 5
6 8 -0.12 180 13.90 385 2 10

Cycle 166 GMT 9/10/2020 9:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 26 13.95 542 2 3
2 12 2005.64 61 9.23 3015 2 2
3 7 2000.60 22 11.28 3109 2 2
4 13 1729.20 38 12.37 2763 2 2
5 13 678.08 38 13.34 1349 2 4
6 8 0.12 180 13.95 383 2 13

Cycle 165 GMT 29/ 9/2020 10:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 25 13.99 543 2 3
2 12 1999.88 61 9.08 2980 2 2
3 7 1993.76 22 11.30 3103 2 2
4 13 1566.60 38 12.53 2551 2 2
5 13 799.16 38 13.23 1520 2 4
6 8 0.08 180 13.93 383 2 8

Cycle 164 GMT 19/ 9/2020 11:14: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 25 13.94 548 2 3
2 3 1020.24 1 12.74 1839 2 2
3 12 2008.72 61 9.08 2968 2 2
4 7 2003.60 22 11.33 3121 2 2
5 13 1581.84 38 12.50 2576 2 2
6 13 932.88 38 13.12 1692 2 4
7 13 26.92 38 14.03 421 2 6
8 8 0.48 180 13.95 378 2 14

Cycle 163 GMT 9/ 9/2020 12:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 26 13.92 551 2 3
2 3 969.68 -1 13.92 551 2 3
3 12 2018.52 61 9.06 3003 2 2
4 7 2013.80 22 11.29 3126 2 2
5 13 1491.60 38 12.58 2448 2 3
6 13 714.36 38 13.29 1398 2 5
7 8 0.00 180 13.94 385 2 12

Cycle 162 GMT 30/ 8/2020 13: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 26 14.02 531 2 3
2 12 1087.48 2 5.81 1757 2 2
3 12 1948.00 61 9.30 2928 2 2
4 7 1941.72 22 11.36 3025 2 2
5 13 1356.32 38 12.68 2275 2 3
6 13 414.36 38 13.59 964 2 5
7 8 0.16 180 13.95 379 2 16

Cycle 161 GMT 20/ 8/2020 12: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 25 14.01 529 2 3
2 3 1025.12 1 12.94 1801 2 2
3 12 1127.96 2 5.87 1688 2 2
4 12 1951.16 61 9.41 2984 2 2
5 7 1945.12 22 11.33 3039 2 2
6 13 1251.68 38 12.81 2130 2 3
7 13 329.00 38 13.68 846 2 6
8 8 0.24 180 13.97 376 2 13

Cycle 160 GMT 10/ 8/2020 10:52: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 25 14.02 540 2 3
2 12 2005.20 61 9.13 3006 2 2
3 7 2000.04 22 11.32 3107 2 2
4 13 1466.76 38 12.60 2427 2 3
5 13 709.00 38 13.31 1392 2 4
6 8 -0.08 180 13.96 375 2 14

Cycle 159 GMT 31/ 7/2020 11:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 25 13.95 537 2 3
2 12 2001.44 61 9.27 2991 2 2
3 7 1996.40 22 11.30 3104 2 2
4 13 1454.84 38 12.65 2404 2 2
5 13 699.16 38 13.33 1376 2 4
6 8 -0.12 180 13.96 378 2 12

Cycle 158 GMT 21/ 7/2020 12:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 26 14.01 542 2 3
2 3 966.60 -1 14.01 542 2 3
3 12 2008.16 61 9.24 2969 2 2
4 7 2003.08 22 11.36 3115 2 2
5 13 1596.56 38 12.50 2588 2 2
6 13 674.72 38 13.35 1341 2 5
7 8 0.64 180 13.98 376 2 8

Cycle 157 GMT 11/ 7/2020 13: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 26 14.04 537 2 3
2 12 2000.40 56 9.14 2986 2 2
3 7 1995.36 22 11.36 3109 2 2
4 13 1719.52 38 12.37 2754 2 2
5 13 676.08 38 13.32 1349 2 4
6 8 -0.24 180 13.95 384 2 9

Cycle 156 GMT 1/ 7/2020 13:47: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 25 14.02 542 2 3
2 3 1037.28 1 12.93 1830 2 2
3 12 2001.72 56 9.30 2963 2 2
4 7 1996.40 22 11.34 3136 2 2
5 13 1725.52 38 12.37 2767 2 2
6 13 662.20 38 13.35 1324 2 5
7 8 0.40 180 13.96 379 2 12

Cycle 155 GMT 21/ 6/2020 14:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 26 13.98 553 2 3
2 3 970.44 -1 13.98 553 2 3
3 12 2004.88 56 9.29 2957 2 2
4 7 2000.32 22 11.34 3126 2 2
5 13 1866.20 38 12.20 2951 2 2
6 13 767.32 38 13.25 1475 2 4
7 8 0.00 180 13.96 381 2 13

Cycle 154 GMT 11/ 6/2020 15:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 26 13.99 551 2 3
2 12 2007.48 48 9.23 2951 2 2
3 7 2003.20 22 11.45 3116 2 2
4 13 1616.20 38 12.48 2630 2 2
5 13 739.36 38 13.26 1438 2 4
6 13 46.48 38 14.02 449 2 6
7 8 0.24 180 13.95 379 2 15

Cycle 153 GMT 1/ 6/2020 15:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 26 14.01 541 2 3
2 12 2005.92 48 9.25 2957 2 2
3 7 2001.04 22 11.38 3123 2 2
4 13 1736.52 38 12.34 2781 2 2
5 13 818.76 38 13.19 1544 2 4
6 8 0.12 180 13.96 380 2 17

Cycle 152 GMT 22/ 5/2020 16:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 26 14.01 543 2 3
2 12 2001.68 48 9.30 2987 2 2
3 7 1996.84 22 11.43 3108 2 2
4 13 1726.60 38 12.37 2778 2 2
5 13 813.48 38 13.22 1536 2 4
6 13 11.76 38 14.06 407 2 6
7 8 -0.28 180 13.92 380 2 13

Cycle 151 GMT 12/ 5/2020 17:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 25 14.01 538 2 3
2 3 1026.60 1 12.75 1808 2 2
3 12 2001.64 45 9.53 2955 2 2
4 7 1997.56 22 11.44 3117 2 2
5 13 1867.60 38 12.21 2936 2 2
6 13 932.28 38 13.11 1701 2 4
7 8 0.12 180 13.96 378 2 11

Cycle 150 GMT 2/ 5/2020 18: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 25 14.00 551 2 3
2 12 2004.92 45 9.47 3031 2 2
3 7 2000.72 22 11.41 3126 2 2
4 13 1867.00 38 12.22 2952 2 2
5 13 937.12 38 13.11 1706 2 3
6 8 0.16 180 13.95 379 2 12

Cycle 149 GMT 22/ 4/2020 18:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 25 14.05 542 2 3
2 12 2006.08 45 9.44 2991 2 2
3 7 2001.84 22 11.47 3097 2 2
4 13 1867.48 38 12.19 2947 2 2
5 13 920.48 38 13.11 1683 2 4
6 8 0.16 180 13.94 381 2 13

Cycle 148 GMT 12/ 4/2020 19:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 25 14.02 546 2 3
2 12 2006.56 45 9.49 3000 2 2
3 7 2001.72 22 11.49 3104 2 2
4 13 1740.08 38 12.35 2793 2 2
5 13 823.96 38 13.19 1553 2 4
6 8 0.20 180 13.96 377 2 13

Cycle 147 GMT 2/ 4/2020 20:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 24 14.06 530 2 3
2 3 1023.96 1 12.64 1804 2 2
3 12 2005.92 45 9.68 2987 2 2
4 7 2001.40 22 11.43 3123 2 2
5 13 1734.24 38 12.35 2778 2 2
6 13 810.28 38 13.21 1528 2 4
7 13 31.56 38 14.03 429 2 6
8 13 18.64 38 13.97 407 2 8
9 8 -0.20 180 13.88 374 2 11

Cycle 146 GMT 23/ 3/2020 21: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 25 14.02 537 2 3
2 3 973.08 -1 14.02 537 2 3
3 12 2004.68 45 9.81 2974 2 2
4 7 2000.04 22 11.46 3109 2 2
5 13 1733.36 38 12.37 2774 2 2
6 13 688.40 38 13.31 1363 2 5
7 8 0.08 180 13.95 374 2 17

Cycle 145 GMT 13/ 3/2020 21:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 24 14.02 541 2 3
2 12 2014.56 45 9.86 2998 2 2
3 7 2010.80 22 11.47 3154 2 2
4 13 1876.68 38 12.22 2958 2 2
5 13 787.36 38 13.23 1491 2 4
6 13 10.04 38 14.06 393 2 8
7 8 0.24 180 13.90 373 2 12

Cycle 144 GMT 3/ 3/2020 22:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 25 14.01 540 2 3
2 3 968.60 -1 14.01 540 2 3
3 12 2007.64 45 9.92 3007 2 2
4 7 2003.20 22 11.51 3131 2 2
5 13 1737.56 38 12.38 2782 2 2
6 13 819.76 38 13.20 1547 2 4
7 8 -0.12 180 13.96 373 2 16

Cycle 143 GMT 22/ 2/2020 23:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 24 14.06 542 2 3
2 3 1054.36 1 12.86 1881 2 2
3 3 1022.00 1 12.36 1853 2 2
4 12 2001.80 45 9.93 3034 2 2
5 7 1996.80 22 11.49 3126 2 2
6 13 1727.96 38 12.37 2772 2 2
7 13 795.44 38 13.21 1512 2 4
8 8 0.36 180 13.94 378 2 9

Cycle 142 GMT 13/ 2/2020 0:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 25 14.04 532 2 3
2 3 958.88 -1 14.04 532 2 3
3 12 2005.36 45 9.98 3024 2 2
4 7 2000.00 22 11.53 3118 2 2
5 13 1719.44 38 12.37 2764 2 2
6 13 784.08 38 13.21 1503 2 4
7 8 -0.04 180 13.93 378 2 15

Cycle 141 GMT 3/ 2/2020 1:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 25 14.05 545 2 3
2 12 2004.96 45 10.05 3033 2 2
3 7 1999.96 22 11.51 3131 2 2
4 13 1590.60 38 12.49 2597 2 3
5 13 689.36 38 13.31 1361 2 5
6 13 14.40 38 14.04 406 2 6
7 8 0.20 180 13.86 380 2 14

Cycle 140 GMT 24/ 1/2020 2: 2: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 25 14.03 545 2 3
2 12 2005.32 45 10.15 3039 2 2
3 7 2000.32 22 11.52 3124 2 2
4 13 1597.08 38 12.51 2601 2 2
5 13 688.36 38 13.29 1361 2 5
6 8 -0.24 180 13.92 380 2 22

Cycle 139 GMT 14/ 1/2020 2:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 25 14.04 530 2 3
2 12 2000.76 45 10.13 3045 2 2
3 7 1995.56 22 11.51 3123 2 2
4 13 1722.88 38 12.37 2769 2 2
5 13 653.80 38 13.33 1317 2 5
6 8 0.32 180 13.93 379 2 11

Cycle 138 GMT 4/ 1/2020 3:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 25 13.99 540 2 3
2 12 2001.56 45 10.18 3049 2 2
3 7 1996.60 22 11.58 3102 2 2
4 13 1582.20 38 12.52 2563 2 2
5 13 674.40 38 13.31 1355 2 5
6 8 0.16 180 13.92 376 2 15

Cycle 137 GMT 25/12/2019 4:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 25 14.03 541 2 3
2 12 2004.44 45 10.26 3060 2 2
3 7 1999.16 22 11.59 3107 2 2
4 13 1720.52 38 12.40 2760 2 2
5 13 777.76 38 13.24 1483 2 4
6 8 -0.16 180 13.92 377 2 15

Cycle 136 GMT 15/12/2019 5: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 25 13.96 545 2 3
2 12 2000.32 45 10.39 3035 2 2
3 7 1995.20 22 11.57 3129 2 2
4 13 1581.72 38 12.52 2576 2 2
5 13 670.60 38 13.31 1332 2 4
6 8 0.20 180 13.90 374 2 9

Cycle 135 GMT 5/12/2019 6: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 25 14.04 520 2 3
2 12 2001.64 45 10.46 3027 2 2
3 7 1996.52 22 11.53 3123 2 2
4 13 1573.52 38 12.53 2551 2 2
5 13 642.08 38 13.35 1289 2 5
6 8 0.00 180 13.89 377 2 13

Cycle 134 GMT 25/11/2019 6:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 25 13.96 544 2 3
2 12 2001.36 45 10.48 3032 2 2
3 7 1996.12 22 11.52 3135 2 2
4 13 1588.44 38 12.52 2579 2 2
5 13 665.72 38 13.33 1323 2 5
6 8 0.44 180 13.89 375 2 10

Cycle 133 GMT 15/11/2019 7:37: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 24 14.00 548 2 3
2 12 2008.84 45 10.57 3035 2 2
3 7 2003.80 22 11.56 3135 2 2
4 13 1594.04 38 12.51 2591 2 3
5 13 673.64 38 13.32 1337 2 5
6 8 -0.20 180 13.91 374 2 14

Cycle 132 GMT 5/11/2019 8: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 25 14.00 532 2 3
2 3 948.00 -1 14.00 532 2 3
3 12 2002.96 45 10.52 3042 2 2
4 7 1998.04 22 11.55 3124 2 2
5 13 1593.00 38 12.51 2593 2 2
6 13 549.36 38 13.44 1160 2 5
7 8 0.16 180 13.91 377 2 13

Cycle 131 GMT 26/10/2019 8:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 24 14.04 531 2 3
2 3 1030.64 1 12.63 1825 2 2
3 12 2000.60 45 10.61 3037 2 2
4 7 1995.48 22 11.62 3110 2 2
5 13 1456.96 38 12.66 2374 2 3
6 13 552.28 38 13.44 1157 2 5
7 8 0.28 180 13.92 373 2 10

Cycle 130 GMT 16/10/2019 9:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 24 14.03 538 2 3
2 12 2000.76 45 10.67 3038 2 2
3 7 1995.28 22 11.57 3136 2 2
4 13 1569.92 38 12.54 2557 2 2
5 13 511.68 38 13.47 1112 2 5
6 8 -0.16 180 13.89 384 2 10

Cycle 129 GMT 6/10/2019 9:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 26 14.03 540 2 3
2 3 962.96 -1 14.03 540 2 3
3 12 2006.08 45 10.61 3051 2 2
4 7 2000.48 22 11.59 3107 2 2
5 13 1581.56 38 12.53 2572 2 2
6 13 647.48 38 13.34 1303 2 5
7 8 0.24 180 13.90 382 2 9

Cycle 128 GMT 26/ 9/2019 10:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 24 14.00 556 2 3
2 3 1030.84 1 12.61 1834 2 2
3 3 1022.36 1 12.17 1841 2 2
4 12 2000.56 45 10.72 3025 2 2
5 7 1994.84 22 11.56 3118 2 2
6 13 1567.92 38 12.56 2544 2 2
7 13 496.68 38 13.49 1084 2 5
8 8 0.12 180 13.90 381 2 22

Cycle 127 GMT 16/ 9/2019 11:29: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 24 13.99 554 2 4
2 12 2002.56 45 10.73 3034 2 2
3 7 1997.28 22 11.56 3120 2 2
4 13 1579.28 38 12.54 2581 2 2
5 13 641.60 38 13.35 1296 2 5
6 8 0.24 180 13.91 382 2 13

Cycle 126 GMT 6/ 9/2019 12:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 24 14.00 532 2 3
2 12 2000.20 45 10.71 3043 2 2
3 7 1994.68 22 11.55 3112 2 2
4 13 1449.28 38 12.64 2406 2 2
5 13 558.44 38 13.42 1179 2 5
6 8 0.04 180 13.89 384 2 15

Cycle 125 GMT 27/ 8/2019 12:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 24 14.02 536 2 3
2 12 2004.48 45 10.76 3040 2 2
3 7 1999.20 22 11.56 3138 2 2
4 13 1571.84 38 12.53 2576 2 2
5 13 646.80 38 13.34 1306 2 5
6 8 0.20 180 13.90 378 2 15

Cycle 124 GMT 17/ 8/2019 13:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 24 13.98 534 2 3
2 12 2007.04 45 10.77 3063 2 2
3 7 2001.80 22 11.62 3130 2 2
4 13 1565.20 38 12.56 2552 2 2
5 13 635.44 38 13.35 1282 2 5
6 8 0.24 180 13.90 376 2 17

Cycle 123 GMT 7/ 8/2019 14:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 24 14.01 539 2 3
2 12 2001.68 45 10.83 3032 2 2
3 7 1996.24 22 11.58 3122 2 2
4 13 1562.44 38 12.55 2555 2 3
5 13 624.88 38 13.36 1275 2 5
6 8 0.12 180 13.84 385 2 16

Cycle 122 GMT 28/ 7/2019 15:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 24 14.03 540 2 3
2 12 2001.84 45 10.77 3036 2 2
3 7 1996.64 22 11.58 3114 2 2
4 13 1708.76 38 12.44 2745 2 2
5 13 740.32 38 13.28 1430 2 5
6 13 9.64 38 14.03 404 2 5
7 8 -0.44 180 13.79 380 2 12

Cycle 121 GMT 18/ 7/2019 16:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 24 14.01 543 2 3
2 12 2000.32 45 10.75 3045 2 2
3 7 1994.48 22 11.61 3114 2 2
4 13 1569.68 38 12.57 2561 2 2
5 13 615.52 38 13.38 1259 2 5
6 8 0.36 180 13.90 377 2 12

Cycle 120 GMT 8/ 7/2019 17: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 24 13.94 541 2 3
2 12 2000.36 45 10.35 3032 2 2
3 7 1995.12 22 11.49 3102 2 2
4 13 1572.24 38 12.54 2567 2 3
5 13 521.44 38 13.47 1117 2 5
6 8 -0.04 180 13.85 391 2 8

Cycle 119 GMT 28/ 6/2019 17:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 24 13.96 533 2 4
2 12 1084.36 45 11.19 1893 2 2
3 12 777.88 40 12.77 1487 2 4
4 7 770.36 22 12.84 1482 4 4
5 8 0.08 180 13.81 388 2 8

Cycle 118 GMT 18/ 6/2019 19:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 24 14.01 546 2 3
2 12 1068.68 45 11.29 1853 2 2
3 12 777.64 40 12.88 1480 2 4
4 7 769.64 22 12.89 1476 4 4
5 8 -0.16 180 13.82 387 2 9

Cycle 117 GMT 8/ 6/2019 21: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 23 14.00 529 2 3
2 12 1173.40 45 11.65 2033 2 2
3 12 812.80 40 12.91 1530 2 3
4 7 805.32 22 12.95 1522 3 3
5 8 0.60 180 13.88 377 2 10

Cycle 116 GMT 29/ 5/2019 22:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 23 14.04 538 2 3
2 12 2000.44 40 10.90 3059 2 2
3 7 1995.64 22 11.66 3122 2 2
4 13 1586.00 36 12.59 2586 2 3
5 13 844.76 36 13.21 1580 2 5
6 8 -0.20 180 13.85 384 2 11

Cycle 115 GMT 19/ 5/2019 23:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 23 13.98 555 2 4
2 12 2000.52 40 10.93 3060 2 2
3 7 1995.44 22 11.67 3121 2 2
4 13 1718.20 36 12.49 2757 2 2
5 13 767.00 36 13.27 1470 2 5
6 13 8.84 36 14.01 408 2 6
7 8 0.32 180 13.78 384 2 6

Cycle 114 GMT 9/ 5/2019 23:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 24 14.00 547 2 3
2 3 973.56 -1 14.00 547 2 3
3 12 2003.80 39 10.96 3043 2 2
4 7 1998.20 22 11.63 3140 2 2
5 13 1572.32 36 12.60 2572 2 3
6 13 813.80 36 13.23 1537 2 5
7 13 23.68 36 13.98 430 2 5
8 8 -0.28 180 13.78 388 2 20

Cycle 113 GMT 30/ 4/2019 0:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 24 13.99 539 2 3
2 12 2005.68 39 10.91 3058 2 2
3 7 2000.80 22 11.62 3134 2 2
4 13 1592.12 36 12.57 2607 2 3
5 13 670.04 36 13.36 1331 2 5
6 8 0.36 180 13.85 386 2 7

Cycle 112 GMT 20/ 4/2019 1: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 24 14.02 543 2 3
2 12 2002.88 39 10.89 3057 2 2
3 7 1998.36 22 11.65 3138 2 2
4 13 1577.36 36 12.63 2552 2 2
5 13 794.92 36 13.25 1501 2 4
6 8 0.24 180 13.84 383 2 8

Cycle 111 GMT 10/ 4/2019 1:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 24 14.00 540 2 3
2 12 2002.72 39 10.94 3063 2 2
3 7 1998.36 22 11.66 3126 2 2
4 13 1478.24 36 12.69 2447 2 3
5 13 726.00 36 13.30 1411 2 5
6 13 40.48 36 13.99 450 2 6
7 8 0.24 180 13.81 385 2 14

Cycle 110 GMT 31/ 3/2019 2:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 23 14.00 549 2 3
2 12 2004.00 39 11.00 3069 2 2
3 7 1998.84 22 11.66 3143 2 2
4 13 1589.52 34 12.64 2600 2 3
5 13 678.04 34 13.37 1343 2 5
6 8 0.04 180 13.84 386 2 11

Cycle 109 GMT 21/ 3/2019 2:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 23 13.98 537 2 3
2 12 2001.84 39 11.03 3033 2 2
3 7 1997.04 22 11.66 3129 2 2
4 13 1583.20 34 12.64 2597 2 3
5 13 670.60 34 13.37 1344 2 5
6 13 64.60 5 13.96 493 2 5
7 13 51.56 5 13.92 490 2 6
8 8 -0.04 180 13.84 386 2 7

Cycle 108 GMT 11/ 3/2019 3:19: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 23 14.01 551 2 3
2 12 2006.92 37 11.03 3043 2 2
3 7 2002.04 22 11.71 3138 2 2
4 13 1604.88 36 12.60 2605 2 3
5 13 699.40 36 13.34 1370 2 5
6 8 -0.08 180 13.84 388 2 10

Cycle 107 GMT 1/ 3/2019 3:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 23 14.02 549 2 3
2 12 2002.64 37 11.08 3040 2 2
3 7 1997.52 22 11.69 3135 2 2
4 13 1717.76 36 12.50 2762 2 2
5 13 761.32 36 13.28 1463 2 5
6 8 -0.04 180 13.82 388 2 11

Cycle 106 GMT 19/ 2/2019 4:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 23 13.99 545 2 3
2 12 2002.12 37 11.05 3072 2 2
3 7 1996.56 22 11.70 3126 2 2
4 13 1715.24 36 12.50 2764 2 2
5 13 647.32 36 13.37 1302 2 5
6 8 0.24 180 13.82 390 2 9

Cycle 105 GMT 9/ 2/2019 5: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 23 14.01 550 2 3
2 12 2001.96 35 11.08 3040 2 2
3 7 1997.80 22 11.73 3124 2 2
4 13 1725.32 36 12.49 2782 2 2
5 13 665.88 36 13.37 1322 2 5
6 8 0.12 180 13.83 388 2 13

Cycle 104 GMT 30/ 1/2019 5:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 24 14.02 536 2 3
2 3 953.72 -1 14.02 536 2 3
3 12 2008.16 35 11.05 3056 2 2
4 7 2004.08 22 11.71 3124 2 2
5 13 1732.04 36 12.47 2790 2 2
6 13 810.68 36 13.24 1530 2 4
7 8 0.12 180 13.81 390 2 6

Cycle 103 GMT 20/ 1/2019 6:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 24 13.97 538 2 3
2 12 2003.84 35 11.01 3059 2 2
3 7 1999.68 22 11.62 3150 2 2
4 13 1722.64 36 12.47 2776 2 2
5 13 671.28 36 13.35 1340 2 5
6 13 5.32 36 14.01 411 2 4
7 8 -0.08 180 13.72 389 2 9

Cycle 102 GMT 10/ 1/2019 6:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 24 13.99 534 2 3
2 12 2001.40 35 11.10 3055 2 2
3 7 1997.56 22 11.69 3130 2 2
4 13 1601.20 36 12.58 2579 2 3
5 13 840.04 36 13.21 1567 2 5
6 8 0.16 180 13.82 390 2 10

Cycle 101 GMT 31/12/2018 7:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 23 13.99 541 2 3
2 12 1109.68 3 12.01 1922 2 2
3 12 1843.16 34 11.28 2931 2 2
4 7 1838.16 22 11.78 2915 2 2
5 13 1271.68 36 12.82 2139 2 3
6 13 372.40 8 13.75 927 2 5
7 13 133.56 5 13.89 601 2 5
8 13 61.20 5 13.94 507 2 5
9 13 50.04 5 13.90 493 2 5
10 8 0.20 180 13.77 394 2 11

Cycle 100 GMT 21/12/2018 6: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 23 13.95 546 2 3
2 12 1096.52 3 11.95 1893 2 2
3 12 1834.72 34 11.31 2901 2 2
4 7 1829.52 22 11.80 2904 2 2
5 13 1267.56 36 12.81 2162 2 3
6 13 344.60 7 13.79 893 2 6
7 13 218.12 5 13.85 727 2 6
8 13 76.04 5 13.94 520 2 5
9 8 0.04 180 13.80 393 2 5

Cycle 99 GMT 11/12/2018 5: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 23 14.00 542 2 4
2 7 2003.44 51 11.24 3124 4 2
3 13 1743.40 36 12.43 2800 2 2
4 13 974.92 36 13.08 1762 2 4
5 8 0.20 180 13.79 393 2 12

Cycle 98 GMT 1/12/2018 5:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 23 13.96 548 2 4
2 7 2003.36 50 11.21 3136 4 2
3 13 1883.24 35 12.26 2989 2 2
4 13 989.64 35 13.08 1754 2 4
5 13 105.16 5 13.90 561 2 5
6 13 2.68 35 14.01 412 2 6
7 8 0.32 180 13.70 389 2 15

Cycle 97 GMT 21/11/2018 5:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 23 13.98 564 2 4
2 7 2005.60 51 11.23 3130 4 2
3 13 1747.64 35 12.43 2812 2 2
4 13 863.40 35 13.18 1598 2 4
5 13 3.64 35 14.05 414 2 3
6 8 -0.16 180 13.69 389 2 12

Cycle 96 GMT 11/11/2018 6:14: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 23 13.99 543 2 3
2 3 1019.16 1 11.60 1826 2 2
3 7 2007.88 51 11.31 3131 2 2
4 13 1747.84 35 12.46 2809 2 2
5 13 741.08 35 13.30 1424 2 5
6 13 6.36 35 13.99 415 2 3
7 8 0.04 180 13.69 391 2 9

Cycle 95 GMT 1/11/2018 6:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 27 14.02 519 2 4
2 3 871.92 -2 14.02 519 2 4
3 3 944.44 -1 14.02 519 2 4
4 7 2003.76 51 11.33 3120 4 2
5 13 1876.68 35 12.29 2978 2 2
6 13 957.04 35 13.13 1705 2 4
7 13 97.68 5 13.94 552 2 5
8 8 0.16 180 13.79 392 2 8

Cycle 94 GMT 22/10/2018 7: 3:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 27 13.89 528 2 3
2 7 2004.56 51 11.35 3135 2 2
3 13 1875.92 35 12.29 2988 2 2
4 13 791.64 35 13.24 1494 2 4
5 13 50.36 5 13.95 483 2 5
6 8 0.04 180 13.80 391 2 9

Cycle 93 GMT 12/10/2018 7:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 27 13.92 550 2 3
2 7 2003.12 51 11.29 3128 3 2
3 13 1723.56 35 12.46 2748 2 2
4 13 1132.40 35 12.95 1956 2 4
5 13 82.76 5 13.92 541 2 5
6 13 43.84 5 13.93 496 2 4
7 13 40.60 5 13.91 496 2 4
8 8 0.04 180 13.68 410 2 12

Cycle 92 GMT 2/10/2018 7:51:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 26 13.93 541 2 3
2 3 1019.56 1 11.62 1842 2 2
3 7 2003.52 51 11.42 3135 2 2
4 13 1728.32 35 12.47 2751 2 2
5 13 957.36 35 13.08 1729 2 4
6 13 40.44 5 13.95 487 2 4
7 8 0.00 180 13.72 410 2 10

Cycle 91 GMT 22/ 9/2018 8:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 26 13.93 559 2 3
2 7 2002.32 50 11.39 3128 3 2
3 13 1879.68 35 12.26 2990 2 2
4 13 855.64 35 13.18 1579 2 5
5 13 107.76 5 13.94 574 2 5
6 8 0.16 180 13.70 412 2 12

Cycle 90 GMT 12/ 9/2018 8:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 26 13.91 542 2 3
2 7 2001.84 50 11.37 3133 3 2
3 13 1608.04 35 12.58 2573 2 3
4 13 878.52 35 13.17 1618 2 5
5 13 113.60 5 13.92 582 2 5
6 13 4.04 35 13.96 427 2 4
7 8 -0.08 180 13.61 406 2 11

Cycle 89 GMT 2/ 9/2018 9:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 26 13.84 548 2 3
2 7 2002.96 50 11.43 3132 2 2
3 13 1882.68 35 12.28 2994 2 2
4 13 832.92 35 13.19 1555 2 5
5 13 65.64 5 13.94 524 2 4
6 13 17.96 35 13.95 440 2 3
7 8 0.24 180 13.66 406 2 8

Cycle 88 GMT 23/ 8/2018 9:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 26 13.96 542 2 3
2 7 2006.84 51 11.38 3137 3 2
3 13 1877.48 35 12.28 2992 2 2
4 13 953.92 35 13.10 1712 2 4
5 13 138.96 5 13.91 612 2 6
6 8 0.04 180 13.72 406 2 6

Cycle 87 GMT 13/ 8/2018 10: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 26 13.95 529 2 3
2 7 2010.28 50 11.40 3141 3 2
3 13 1891.20 35 12.29 2998 2 2
4 13 1014.04 35 13.06 1801 2 4
5 13 191.72 5 13.87 684 2 7
6 13 45.08 5 13.97 483 2 4
7 8 0.24 180 13.73 402 2 4

Cycle 86 GMT 3/ 8/2018 10:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 26 13.92 545 2 3
2 7 2007.52 50 11.41 3140 2 2
3 13 1744.68 35 12.46 2785 2 2
4 13 697.36 35 13.32 1360 2 5
5 13 4.60 35 13.99 422 2 5
6 8 0.04 180 13.64 402 2 13

Cycle 85 GMT 24/ 7/2018 10:25: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 25 13.96 534 2 3
2 7 2004.04 51 11.39 3136 2 2
3 13 1747.28 35 12.44 2806 2 2
4 13 855.60 35 13.20 1586 2 5
5 13 52.76 5 13.94 487 2 5
6 8 0.16 180 13.73 404 2 10

Cycle 84 GMT 14/ 7/2018 10:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 23 13.93 548 2 3
2 3 1049.08 1 13.32 1895 2 2
3 7 2002.28 51 11.38 3132 2 2
4 13 1590.76 35 12.60 2560 2 2
5 13 813.32 35 13.23 1529 2 5
6 13 62.72 5 13.97 507 2 4
7 13 16.56 35 13.97 440 2 3
8 8 -0.20 180 13.61 403 2 9

Cycle 83 GMT 4/ 7/2018 11:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 23 14.00 526 2 3
2 3 1034.40 1 13.18 1850 2 2
3 7 2006.28 50 11.37 3140 2 2
4 13 1740.24 35 12.47 2779 2 2
5 13 851.12 35 13.20 1576 2 5
6 13 74.16 5 13.97 517 2 5
7 13 59.16 5 13.94 506 2 5
8 13 50.48 5 13.92 499 2 5
9 13 45.52 5 13.92 488 2 5
10 8 0.36 180 13.72 400 2 13

Cycle 82 GMT 24/ 6/2018 11:23: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 24 14.05 544 2 4
2 3 949.08 -1 14.05 544 2 4
3 7 2034.72 51 11.30 3178 4 2
4 13 1931.32 35 12.26 3057 2 2
5 13 1313.04 35 12.85 2206 2 3
6 13 59.44 5 13.98 497 2 5
7 13 49.72 5 13.94 496 2 5
8 13 17.64 35 13.97 439 2 3
9 8 -0.04 180 13.64 398 2 7

Cycle 81 GMT 14/ 6/2018 11:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 22 14.01 560 2 4
2 3 1051.20 1 13.39 1903 2 2
3 7 2004.32 51 11.31 3125 2 2
4 13 1743.88 35 12.46 2817 2 2
5 13 719.08 35 13.33 1399 2 5
6 13 16.96 35 14.01 430 2 5
7 8 0.12 180 13.67 395 2 9

Cycle 80 GMT 4/ 6/2018 11:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 22 14.07 548 2 3
2 7 2004.36 51 11.28 3123 3 2
3 13 1745.24 35 12.50 2794 2 2
4 13 971.56 35 13.15 1739 2 4
5 13 61.20 5 13.96 494 2 5
6 13 55.48 5 13.97 495 2 5
7 13 50.84 5 13.95 492 2 5
8 13 47.72 5 13.92 486 2 5
9 13 44.64 5 13.90 479 2 5
10 13 41.92 5 13.91 474 2 5
11 8 -0.24 180 13.75 393 2 9

Cycle 79 GMT 25/ 5/2018 11:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 22 14.04 563 2 4
2 7 2007.72 50 11.37 3142 4 2
3 13 1604.72 35 12.61 2612 2 3
4 13 891.64 35 13.21 1638 2 4
5 13 72.36 5 13.97 518 2 5
6 8 0.24 180 13.82 397 2 10

Cycle 78 GMT 15/ 5/2018 12:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 22 14.05 553 2 3
2 7 2007.52 50 11.31 3146 2 2
3 13 1875.04 35 12.33 2970 2 2
4 13 921.72 35 13.18 1684 2 4
5 13 80.84 5 13.95 536 2 5
6 13 60.84 5 13.97 513 2 5
7 13 16.16 35 13.99 434 2 6
8 8 0.08 180 13.67 397 2 15

Cycle 77 GMT 5/ 5/2018 12:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 22 14.06 542 2 4
2 7 2003.44 50 11.24 3139 2 2
3 13 1747.12 35 12.50 2785 2 2
4 13 830.36 35 13.27 1550 2 5
5 13 51.12 5 14.01 488 2 5
6 8 -0.08 180 13.80 396 2 11

Cycle 76 GMT 25/ 4/2018 13: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 22 14.05 556 2 3
2 3 972.64 -1 14.05 556 2 3
3 3 1022.84 1 12.72 1849 2 2
4 7 2004.64 50 11.30 3141 2 2
5 13 1745.52 35 12.53 2798 2 2
6 13 959.44 35 13.18 1734 2 4
7 13 4.08 35 14.06 414 2 3
8 8 -0.12 180 13.73 395 2 13

Cycle 75 GMT 15/ 4/2018 13:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 22 14.12 551 2 3
2 7 2004.40 51 11.25 3140 3 2
3 13 1740.76 35 12.53 2798 2 2
4 13 845.80 35 13.28 1574 2 4
5 13 45.96 5 14.00 475 2 5
6 13 43.60 5 14.01 476 2 5
7 13 40.80 5 14.00 475 2 5
8 8 0.20 180 13.79 394 2 11

Cycle 74 GMT 5/ 4/2018 14: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 21 14.12 542 2 3
2 3 1028.64 1 13.22 1864 2 2
3 7 2008.88 50 11.32 3143 2 2
4 13 1739.88 35 12.55 2792 2 2
5 13 715.84 35 13.40 1398 2 5
6 8 -0.20 180 13.85 393 2 11

Cycle 73 GMT 26/ 3/2018 14:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 22 14.08 550 2 4
2 3 970.52 -1 14.08 550 2 4
3 7 2001.84 51 11.28 3129 2 2
4 13 1873.84 35 12.37 2985 2 2
5 13 958.28 35 13.22 1726 2 4
6 13 48.12 5 14.02 486 2 5
7 8 0.04 180 13.82 398 2 12

Cycle 72 GMT 16/ 3/2018 15: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 22 14.13 549 2 4
2 7 2004.72 50 11.20 3134 4 2
3 13 1873.32 35 12.37 2985 2 2
4 13 947.40 35 13.22 1725 2 4
5 13 81.20 5 14.02 527 2 5
6 13 44.12 5 14.02 484 2 5
7 8 0.00 180 13.85 393 2 8

Cycle 71 GMT 6/ 3/2018 15:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 22 14.14 539 2 3
2 7 2004.80 50 11.27 3134 3 2
3 13 1749.68 35 12.57 2805 2 3
4 13 981.16 35 13.22 1760 2 4
5 8 0.48 180 13.82 400 2 10

Cycle 70 GMT 24/ 2/2018 15:50: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 22 14.08 555 2 4
2 7 2003.76 51 11.30 3142 4 2
3 13 1749.20 35 12.59 2822 2 2
4 13 845.52 35 13.33 1580 2 5
5 13 5.92 35 14.08 417 2 5
6 8 -0.16 180 13.75 393 2 13

Cycle 69 GMT 14/ 2/2018 16:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 22 14.14 530 2 4
2 7 2002.84 50 11.39 3131 4 2
3 13 1743.52 35 12.61 2790 2 2
4 13 838.92 35 13.36 1562 2 5
5 13 6.48 35 14.09 412 2 3
6 8 -0.08 180 13.76 390 2 8

Cycle 68 GMT 4/ 2/2018 16:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 21 14.13 538 2 3
2 3 1027.12 1 13.59 1866 2 2
3 7 2002.32 51 11.47 3132 2 2
4 13 1607.96 35 12.76 2609 2 3
5 13 848.80 35 13.36 1574 2 5
6 8 0.52 180 13.88 391 2 11

Cycle 67 GMT 25/ 1/2018 17:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 21 14.15 547 2 4
2 7 2007.44 50 11.51 3136 2 2
3 13 1607.84 35 12.77 2593 2 3
4 13 842.76 35 13.38 1571 2 5
5 13 44.72 5 14.02 481 2 5
6 8 -0.24 180 13.85 395 2 9

Cycle 66 GMT 15/ 1/2018 17:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 22 14.08 557 2 4
2 3 972.08 -1 14.08 557 2 4
3 7 2002.76 51 11.51 3137 2 2
4 13 1745.52 35 12.66 2789 2 2
5 13 819.84 35 13.40 1539 2 5
6 13 16.68 35 14.08 428 2 5
7 8 -0.24 180 13.76 391 2 9

Cycle 65 GMT 5/ 1/2018 18:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 22 14.15 542 2 4
2 7 2003.96 50 11.55 3144 4 2
3 13 1876.96 35 12.47 2997 2 2
4 13 926.32 35 13.33 1693 2 5
5 13 54.60 5 14.05 495 2 5
6 13 16.16 35 14.08 432 2 5
7 8 -0.08 180 13.75 395 2 11

Cycle 64 GMT 26/12/2017 18:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 24 14.08 555 2 4
2 3 945.32 -1 14.08 555 2 4
3 7 2003.20 51 11.57 3143 4 2
4 13 1738.96 35 12.70 2777 2 2
5 13 703.48 35 13.51 1380 2 5
6 8 0.24 180 13.88 402 2 10

Cycle 63 GMT 16/12/2017 19:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 22 14.12 557 2 4
2 3 1036.88 1 13.79 1881 2 2
3 7 2003.68 50 11.67 3140 2 2
4 13 1736.68 35 12.72 2782 2 2
5 13 828.80 35 13.44 1556 2 5
6 13 58.64 5 14.03 504 2 5
7 13 50.40 5 14.03 500 2 5
8 13 44.92 5 14.04 492 2 5
9 13 41.88 5 14.02 490 2 5
10 8 0.00 180 13.82 400 2 12

Cycle 62 GMT 6/12/2017 19:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 24 14.06 557 2 4
2 3 956.24 -1 14.06 557 2 4
3 7 2003.00 50 11.75 3139 2 2
4 13 1872.28 35 12.53 2990 2 2
5 13 680.56 35 13.54 1349 2 5
6 13 43.60 5 14.05 479 2 4
7 13 40.36 5 14.09 481 2 4
8 8 0.04 180 13.85 400 2 16

Cycle 61 GMT 26/11/2017 20:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 23 14.17 544 2 3
2 3 1027.40 1 13.82 1882 2 2
3 7 2005.88 50 11.86 3142 2 2
4 13 1606.96 35 12.87 2609 2 3
5 13 715.56 35 13.53 1397 2 5
6 13 51.40 5 14.06 487 2 4
7 13 45.80 5 14.05 491 2 4
8 13 42.80 5 14.07 481 2 5
9 8 0.32 180 13.85 399 2 11

Cycle 60 GMT 16/11/2017 20:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 22 14.15 551 2 4
2 3 1043.68 1 13.90 1901 2 2
3 7 2005.96 50 11.86 3151 2 2
4 13 1598.96 35 12.91 2582 2 3
5 13 824.52 35 13.46 1549 2 5
6 8 0.20 180 13.88 398 2 8

Cycle 59 GMT 6/11/2017 20:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 24 14.09 555 2 4
2 3 940.08 -1 14.09 555 2 4
3 3 973.64 -1 14.09 555 2 4
4 7 2002.72 55 11.91 3151 4 2
5 13 1869.64 32 12.69 2983 2 2
6 13 752.76 32 13.57 1445 2 5
7 13 2.56 32 14.14 415 2 3
8 8 -0.12 180 13.82 397 2 6

Cycle 58 GMT 27/10/2017 21:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 24 14.15 553 2 4
2 7 2002.80 55 11.99 3148 4 2
3 13 1588.84 32 13.00 2587 2 3
4 13 672.32 32 13.62 1340 2 5
5 13 3.60 32 14.12 421 2 3
6 8 0.20 180 13.82 401 2 16

Cycle 57 GMT 17/10/2017 21:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 23 14.17 536 2 3
2 3 1031.68 1 13.92 1897 2 2
3 7 2002.08 55 12.14 3144 2 2
4 13 1569.24 32 13.06 2549 2 3
5 13 665.72 32 13.65 1327 2 6
6 8 0.04 180 13.91 404 2 13

Cycle 56 GMT 7/10/2017 22:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 23 14.10 567 2 4
2 7 2002.96 56 12.19 3150 2 2
3 13 1590.32 32 13.05 2580 2 3
4 13 528.40 32 13.74 1133 2 6
5 8 0.04 180 13.90 400 2 10

Cycle 55 GMT 27/ 9/2017 22:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 23 14.11 547 2 4
2 7 2002.44 55 12.23 3154 4 2
3 13 1454.44 32 13.15 2401 2 3
4 13 686.76 32 13.64 1359 2 6
5 8 0.16 180 13.90 401 2 10

Cycle 54 GMT 17/ 9/2017 22:39:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 24 14.18 539 2 4
2 3 941.12 -1 14.18 539 2 4
3 7 2003.68 51 12.32 3149 4 2
4 13 1585.44 34 13.06 2562 2 3
5 13 663.04 34 13.64 1318 2 5
6 8 0.12 180 13.91 400 2 16

Cycle 53 GMT 7/ 9/2017 22:56: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 24 14.16 548 2 3
2 7 2006.84 51 12.37 3149 2 2
3 13 1735.40 34 12.95 2791 2 3
4 13 656.20 34 13.65 1314 2 6
5 8 -0.20 180 13.91 402 2 10

Cycle 52 GMT 28/ 8/2017 23:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 24 14.17 556 2 3
2 7 2003.40 51 12.35 3155 3 2
3 13 1573.88 34 13.07 2556 2 3
4 13 646.72 34 13.66 1306 2 5
5 8 -0.04 180 13.90 409 2 12

Cycle 51 GMT 18/ 8/2017 23:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 24 14.17 548 2 3
2 7 2006.44 51 12.33 3159 3 2
3 13 1598.52 34 13.04 2594 2 3
4 13 688.60 34 13.63 1363 2 6
5 8 0.28 180 13.91 405 2 10

Cycle 50 GMT 9/ 8/2017 0: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 24 14.15 546 2 3
2 7 2006.04 51 12.33 3154 3 2
3 13 1604.08 34 13.03 2595 2 3
4 13 670.36 34 13.64 1334 2 6
5 8 -0.08 180 13.94 404 2 18

Cycle 49 GMT 30/ 7/2017 0:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 24 14.22 548 2 3
2 7 2002.84 51 12.31 3149 2 2
3 13 1592.00 34 13.03 2576 2 3
4 13 675.36 34 13.63 1349 2 6
5 13 45.92 5 14.08 488 2 4
6 8 0.36 180 13.95 404 2 10

Cycle 48 GMT 20/ 7/2017 0:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 24 14.19 538 2 3
2 7 2005.36 51 12.31 3152 3 2
3 13 1472.12 34 13.11 2426 2 3
4 13 448.64 34 13.81 1024 2 6
5 8 -0.04 190 13.93 404 2 10

Cycle 47 GMT 10/ 7/2017 0:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 23 14.20 536 2 3
2 3 1036.16 1 14.12 1888 2 2
3 7 2002.48 51 12.31 3151 2 2
4 13 1597.60 34 13.03 2590 2 3
5 13 680.60 34 13.65 1343 2 5
6 8 -0.08 190 13.96 401 2 8

Cycle 46 GMT 30/ 6/2017 0:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 23 14.25 556 2 4
2 7 2002.12 51 12.32 3156 4 2
3 13 1456.40 34 13.14 2409 2 3
4 13 568.12 34 13.74 1191 2 6
5 8 0.36 190 13.95 405 2 8

Cycle 45 GMT 20/ 6/2017 0:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 23 14.21 559 2 4
2 7 2007.96 51 12.36 3152 2 2
3 13 1586.28 34 13.08 2570 2 3
4 13 817.28 34 13.58 1540 2 6
5 13 16.44 34 14.20 432 2 3
6 8 0.12 190 13.88 402 2 7

Cycle 44 GMT 10/ 6/2017 1:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 22 14.29 539 2 3
2 3 1019.52 1 14.08 1877 2 2
3 7 2002.36 48 12.44 3151 2 2
4 13 1872.24 34 12.79 2977 2 3
5 13 626.80 34 13.72 1271 2 6
6 8 0.00 190 13.97 398 2 13

Cycle 43 GMT 31/ 5/2017 1:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 22 14.30 549 2 4
2 7 2002.84 49 12.51 3142 2 2
3 13 1728.80 34 13.03 2759 2 3
4 13 637.56 34 13.72 1288 2 6
5 13 43.64 5 14.16 484 2 5
6 13 40.44 5 14.23 487 2 5
7 8 0.32 190 13.95 404 2 12

Cycle 42 GMT 21/ 5/2017 2:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 23 14.25 559 2 4
2 3 952.84 -1 14.25 559 2 4
3 7 2004.04 48 12.57 3140 4 2
4 13 1496.60 34 13.19 2458 2 3
5 13 498.64 34 13.85 1088 2 6
6 13 16.48 34 14.23 434 2 4
7 8 0.08 190 13.92 400 2 16

Cycle 41 GMT 11/ 5/2017 2:12: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 23 14.32 560 2 4
2 3 1031.12 1 14.22 1891 2 2
3 7 2001.88 48 12.58 3158 2 2
4 13 1472.24 34 13.22 2427 2 3
5 13 455.36 34 13.90 1028 2 6
6 13 45.08 5 14.21 488 2 5
7 8 0.16 190 14.00 402 2 13

Cycle 40 GMT 1/ 5/2017 2:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 22 14.30 555 2 4
2 7 2007.04 48 12.62 3141 2 2
3 13 1483.56 34 13.23 2425 2 3
4 13 358.64 8 14.07 916 2 6
5 13 250.04 5 14.12 767 2 6
6 13 154.36 5 14.17 633 2 5
7 13 46.36 5 14.24 486 2 5
8 8 0.32 190 14.02 399 2 10

Cycle 39 GMT 21/ 4/2017 2: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 22 14.35 553 2 4
2 7 2003.32 48 12.67 3109 4 2
3 13 1347.48 34 13.32 2268 2 3
4 13 477.76 34 13.91 1053 2 7
5 13 5.32 34 14.28 416 2 4
6 8 -0.20 190 13.97 394 2 15

Cycle 38 GMT 11/ 4/2017 2:10: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 22 14.31 554 2 4
2 7 2002.72 49 12.68 3137 4 2
3 13 1370.88 34 13.30 2313 2 4
4 13 383.60 8 14.10 956 2 6
5 13 158.64 5 14.20 641 2 6
6 13 100.36 5 14.23 567 2 5
7 13 7.60 34 14.28 428 2 4
8 8 -0.12 190 13.96 397 2 11

Cycle 37 GMT 1/ 4/2017 1:34: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 22 14.38 539 2 4
2 3 1019.08 1 14.23 1855 2 2
3 7 2006.44 39 12.86 3154 2 2
4 13 1642.76 18 13.41 2686 2 3
5 13 1119.08 18 13.70 1966 2 4
6 13 488.12 18 14.04 1080 2 6
7 13 81.08 5 14.25 529 2 5
8 13 62.76 5 14.30 517 2 5
9 13 51.96 5 14.28 501 2 5
10 13 43.68 5 14.28 491 2 4
11 13 41.08 5 14.30 485 2 5
12 8 0.48 190 14.02 402 2 14

Cycle 36 GMT 22/ 3/2017 1:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 22 14.40 542 2 3
2 7 2007.16 39 12.88 3157 2 2
3 13 1892.80 18 13.22 3023 2 3
4 13 1378.20 18 13.56 2338 2 4
5 13 722.96 18 13.93 1418 2 6
6 13 200.28 5 14.22 693 2 6
7 13 126.28 5 14.25 598 2 5
8 13 86.96 5 14.27 547 2 5
9 13 64.56 5 14.28 524 2 5
10 8 -0.24 190 14.06 397 2 9

Cycle 35 GMT 12/ 3/2017 0:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 21 14.40 545 2 4
2 3 1024.64 1 14.27 1876 2 2
3 7 2003.52 39 12.91 3150 2 2
4 13 1760.36 18 13.39 2834 2 3
5 13 1095.64 18 13.73 1942 2 4
6 13 579.40 18 14.03 1211 2 6
7 13 72.24 5 14.27 532 2 4
8 13 56.64 5 14.32 513 2 5
9 13 48.92 5 14.30 504 2 4
10 8 -0.04 190 14.05 399 2 15

Cycle 34 GMT 1/ 3/2017 23:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 24 14.36 545 2 4
2 3 915.92 -2 14.36 545 2 4
3 7 2003.64 39 12.94 3143 4 2
4 13 1601.68 18 13.48 2620 2 3
5 13 986.04 18 13.80 1791 2 5
6 13 386.60 18 14.14 942 2 6
7 13 89.36 18 14.31 539 2 4
8 8 -0.16 190 14.05 401 2 13

Cycle 33 GMT 19/ 2/2017 22:58: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 22 14.40 557 2 4
2 3 1055.92 1 14.41 1919 2 3
3 7 2003.52 39 12.97 3153 2 2
4 13 1803.20 19 13.32 2896 2 3
5 13 974.80 19 13.78 1760 2 5
6 13 371.60 19 14.15 914 2 6
7 13 74.00 19 14.33 517 2 4
8 8 -0.04 190 14.07 397 2 10

Cycle 32 GMT 9/ 2/2017 22: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 22 14.41 537 2 4
2 7 2002.32 40 12.98 3133 4 2
3 13 1596.08 19 13.46 2609 2 3
4 13 950.12 19 13.81 1729 2 5
5 13 323.36 7 14.22 873 2 6
6 13 193.20 5 14.27 696 2 6
7 13 120.44 5 14.30 591 2 5
8 13 62.52 5 14.31 516 2 5
9 8 0.32 190 14.09 397 2 13

Cycle 31 GMT 30/ 1/2017 21:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 22 14.36 545 2 4
2 7 2002.64 44 12.95 3116 2 2
3 13 1370.44 20 13.59 2298 2 3
4 13 747.76 20 13.93 1444 2 6
5 13 186.00 5 14.28 681 2 6
6 13 121.56 5 14.31 600 2 5
7 13 82.12 5 14.31 548 2 5
8 13 63.20 5 14.33 526 2 5
9 8 0.04 190 14.08 401 2 8

Cycle 30 GMT 20/ 1/2017 20:42: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 23 14.38 557 2 4
2 3 963.80 -1 14.38 557 2 4
3 7 2002.44 45 12.96 3125 2 2
4 13 1380.76 20 13.58 2333 2 3
5 13 757.52 20 13.94 1458 2 6
6 13 193.04 5 14.30 680 2 6
7 13 120.72 5 14.32 590 2 5
8 13 48.72 5 14.34 496 2 4
9 13 18.00 20 14.37 448 2 3
10 8 -0.04 190 14.06 401 2 13

Cycle 29 GMT 10/ 1/2017 19:56: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 23 14.32 545 2 3
2 7 2004.96 45 12.99 3127 3 2
3 13 1351.68 20 13.60 2277 2 3
4 13 752.20 20 13.94 1463 2 6
5 13 184.72 5 14.29 685 2 6
6 13 121.52 5 14.31 598 2 6
7 13 88.16 5 14.33 558 2 5
8 13 66.76 5 14.36 530 2 5
9 13 5.56 20 14.35 434 2 3
10 8 0.04 190 14.03 405 2 15

Cycle 28 GMT 31/12/2016 19:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 22 14.40 539 2 3
2 3 1023.20 1 14.36 1881 2 2
3 7 2007.40 45 12.99 3123 2 2
4 13 1374.36 20 13.61 2305 2 4
5 13 756.44 20 13.94 1467 2 6
6 13 312.12 6 14.26 861 2 6
7 13 117.24 5 14.34 585 2 5
8 13 79.16 5 14.36 542 2 4
9 13 44.76 5 14.38 502 2 4
10 8 0.12 190 14.06 406 2 8

Cycle 27 GMT 21/12/2016 18:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 24 14.40 554 2 3
2 3 968.76 -1 14.40 554 2 3
3 7 2003.64 44 13.01 3124 2 2
4 13 1584.36 20 13.50 2586 2 3
5 13 715.40 20 13.98 1400 2 6
6 13 171.32 5 14.31 651 2 6
7 13 108.92 5 14.33 574 2 5
8 13 75.64 5 14.36 537 2 5
9 8 0.04 190 14.09 405 2 7

Cycle 26 GMT 11/12/2016 17:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 23 14.41 544 2 3
2 3 1027.88 1 14.44 1873 2 2
3 7 2004.00 50 12.95 3120 2 2
4 13 1339.36 28 13.49 2269 2 3
5 13 403.96 28 14.10 948 2 7
6 13 5.36 28 14.39 425 2 3
7 8 0.32 190 14.04 403 2 17

Cycle 25 GMT 1/12/2016 17:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 22 14.45 529 2 3
2 7 2005.72 51 12.93 3112 2 2
3 13 1147.84 28 13.61 1979 2 4
4 13 292.72 6 14.28 825 2 6
5 13 188.88 5 14.34 679 2 6
6 13 121.72 5 14.35 587 2 5
7 13 81.24 5 14.36 546 2 5
8 13 6.28 28 14.35 434 2 4
9 8 0.28 190 14.03 403 2 9

Cycle 24 GMT 21/11/2016 16:58: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 24 14.42 549 2 3
2 3 965.84 -1 14.42 549 2 3
3 7 2002.64 51 12.94 3131 2 2
4 13 1329.12 28 13.51 2234 2 4
5 13 427.56 28 14.09 984 2 7
6 8 -0.12 190 14.11 405 2 7

Cycle 23 GMT 11/11/2016 16:48:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 24 14.41 549 2 3
2 7 2002.48 50 12.96 3137 3 2
3 13 1337.20 28 13.52 2240 2 4
4 13 431.04 28 14.09 1001 2 7
5 8 0.04 190 14.11 409 2 13

Cycle 22 GMT 1/11/2016 16:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 23 14.41 558 2 3
2 7 2003.36 50 12.98 3129 2 3
3 13 1336.92 28 13.52 2245 2 4
4 13 417.16 28 14.11 981 2 7
5 8 0.44 190 14.11 409 2 14

Cycle 21 GMT 22/10/2016 16:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 23 14.43 560 2 3
2 7 2004.12 50 12.99 3161 3 2
3 13 1355.60 28 13.52 2274 2 4
4 13 422.76 28 14.11 982 2 6
5 8 0.36 190 14.11 409 2 12

Cycle 20 GMT 12/10/2016 15:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 23 14.39 567 2 3
2 3 1019.88 1 14.48 1871 2 2
3 7 2004.16 50 13.02 3111 2 3
4 13 1150.40 28 13.64 2000 2 4
5 13 293.68 6 14.31 837 2 6
6 13 182.88 5 14.36 680 2 6
7 13 120.92 5 14.39 592 2 6
8 13 84.64 5 14.41 555 2 5
9 13 17.08 28 14.37 455 2 3
10 8 0.00 190 14.05 409 2 13

Cycle 19 GMT 2/10/2016 14:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 23 14.42 548 2 3
2 7 2003.64 50 13.02 3131 3 3
3 13 1331.88 28 13.55 2231 2 4
4 13 420.16 28 14.11 996 2 7
5 13 6.52 28 14.40 435 2 3
6 8 0.32 190 14.03 408 2 11

Cycle 18 GMT 22/ 9/2016 14:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 22 14.42 558 2 3
2 3 1030.60 1 14.51 1900 2 2
3 7 2002.04 50 13.04 3127 2 2
4 13 1161.96 28 13.64 2031 2 4
5 13 300.48 6 14.32 847 2 6
6 13 193.36 5 14.37 706 2 6
7 13 124.44 5 14.41 610 2 6
8 13 84.16 5 14.41 558 2 5
9 13 5.28 28 14.39 445 2 3
10 8 0.64 190 14.03 411 2 11

Cycle 17 GMT 12/ 9/2016 13:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 22 14.43 557 2 3
2 7 2003.20 51 13.02 3119 2 3
3 13 1328.64 28 13.55 2237 2 4
4 13 359.84 8 14.29 926 2 6
5 13 205.08 5 14.36 721 2 6
6 13 132.84 5 14.40 614 2 5
7 13 87.20 5 14.42 558 2 5
8 8 -0.08 190 14.09 414 2 7

Cycle 16 GMT 2/ 9/2016 13:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 22 14.43 555 2 3
2 7 2001.60 51 13.05 3120 3 3
3 13 1341.52 28 13.55 2261 2 4
4 13 420.84 28 14.13 987 2 7
5 13 17.56 28 14.42 454 2 3
6 8 0.08 190 14.04 411 2 11

Cycle 15 GMT 23/ 8/2016 13: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 21 14.45 563 2 4
2 3 1018.68 1 14.47 1890 2 2
3 7 2002.64 50 13.07 3148 2 2
4 13 1322.92 28 13.57 2238 2 4
5 13 400.84 28 14.15 960 2 7
6 8 0.20 190 14.12 410 2 15

Cycle 14 GMT 13/ 8/2016 12:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 21 14.47 566 2 4
2 3 1027.20 1 14.52 1891 2 2
3 7 2003.00 51 13.07 3134 2 2
4 13 1113.08 28 13.68 1960 2 4
5 13 249.92 5 14.36 768 2 6
6 13 158.20 5 14.42 643 2 6
7 13 104.96 5 14.45 578 2 6
8 13 73.56 5 14.44 542 2 5
9 13 17.64 28 14.41 452 2 4
10 8 -0.08 190 14.07 409 2 12

Cycle 13 GMT 3/ 8/2016 11:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 20 14.49 558 2 4
2 7 2003.64 50 13.08 3116 2 3
3 13 1330.76 28 13.58 2237 2 4
4 13 414.40 28 14.14 974 2 7
5 13 49.88 5 14.53 499 2 5
6 8 0.88 190 14.13 409 2 10

Cycle 12 GMT 24/ 7/2016 11:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 20 14.50 566 2 4
2 7 2002.24 51 13.09 3134 2 2
3 13 1309.64 28 13.59 2216 2 3
4 13 389.96 8 14.33 961 2 7
5 13 218.80 5 14.45 729 2 6
6 13 132.40 5 14.49 612 2 6
7 13 42.88 5 14.54 495 2 5
8 8 -0.32 190 14.15 404 2 16

Cycle 11 GMT 14/ 7/2016 10:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 19 14.52 561 2 5
2 7 2002.96 51 13.08 3132 2 2
3 13 1146.64 28 13.65 2003 2 4
4 13 450.36 28 14.11 1028 2 7
5 13 4.80 28 14.49 426 2 5
6 8 0.04 190 14.08 404 2 11

Cycle 10 GMT 4/ 7/2016 10:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 21 14.48 550 2 5
2 3 952.44 -1 14.48 550 2 5
3 7 2002.16 51 13.08 3134 5 2
4 13 1124.44 28 13.66 1971 2 4
5 13 258.68 5 14.40 787 2 6
6 13 169.36 5 14.44 662 2 6
7 13 111.56 5 14.48 583 2 6
8 13 17.00 28 14.45 451 2 5
9 8 -0.48 190 14.06 400 2 18

Cycle 9 GMT 24/ 6/2016 9:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 21 14.50 550 2 4
2 7 2001.72 50 13.09 3126 4 2
3 13 1317.16 28 13.54 2247 2 4
4 13 391.20 8 14.33 958 2 6
5 13 231.72 5 14.44 740 2 6
6 13 89.04 5 14.53 549 2 6
7 13 46.16 5 14.54 496 2 4
8 8 0.56 190 14.15 397 2 11

Cycle 8 GMT 14/ 6/2016 8:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 20 14.49 566 2 5
2 3 1028.36 1 14.50 1892 2 3
3 7 2005.24 50 13.07 3139 2 3
4 13 1319.88 28 13.55 2219 2 3
5 13 400.64 28 14.16 954 2 6
6 8 0.08 190 14.15 398 2 16

Cycle 7 GMT 4/ 6/2016 7:30: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 19 14.49 565 2 5
2 3 1037.48 1 14.51 1875 2 3
3 7 2002.88 50 13.06 3100 2 2
4 13 1315.96 28 13.52 2218 2 4
5 13 382.64 8 14.33 938 2 6
6 13 139.08 5 14.50 606 2 6
7 13 91.68 5 14.49 546 2 5
8 13 17.96 28 14.45 442 2 4
9 8 -0.08 190 14.07 402 2 15

Cycle 6 GMT 25/ 5/2016 6:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 14 14.54 546 2 4
2 10 1005.84 3 14.49 1809 2 4
3 3 1047.32 1 14.54 1906 2 4
4 7 2002.20 74 12.88 3085 2 2
5 13 513.00 25 14.08 1111 2 7
6 13 91.04 5 14.52 538 2 6
7 8 0.16 190 14.11 402 2 15

Cycle 5 GMT 15/ 5/2016 5:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 23 14.36 545 2 6
2 3 746.96 -5 14.36 545 2 6
3 3 902.68 -2 14.36 545 2 6
4 7 1989.64 74 12.85 3074 6 2
5 13 526.88 25 14.06 1128 2 7
6 13 64.72 5 14.53 504 2 6
7 8 0.08 190 14.11 400 2 14

Cycle 4 GMT 5/ 5/2016 4:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 18 14.44 556 2 4
2 7 1504.04 74 13.06 2466 2 3
3 13 315.64 6 14.29 849 2 6
4 13 189.84 5 14.38 680 2 5
5 13 80.88 5 14.45 528 2 5
6 13 62.64 5 14.43 511 2 6
7 13 43.16 5 14.42 480 2 5
8 13 40.36 5 14.38 478 2 5
9 13 17.36 25 14.33 438 2 5
10 8 0.40 190 13.99 394 2 14

Cycle 3 GMT 4/ 5/2016 4:48: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 21 14.38 560 2 4
2 3 924.92 -1 14.38 560 2 4
3 3 966.64 -1 14.38 560 2 4
4 7 1507.44 75 12.97 2458 4 3
5 13 294.96 6 14.24 823 2 7
6 13 184.20 5 14.31 674 2 7
7 13 112.68 5 14.35 575 2 6
8 13 48.76 5 14.41 488 2 6
9 13 16.28 25 14.35 435 2 4
10 8 -0.16 190 13.97 391 2 10

Cycle 2 GMT 3/ 5/2016 5: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 23 14.31 546 2 5
2 3 918.48 -2 14.31 546 2 5
3 7 1509.96 74 12.84 2409 5 3
4 13 342.64 7 14.13 870 2 5
5 13 204.84 5 14.23 690 2 7
6 13 132.08 5 14.31 588 2 5
7 13 87.52 5 14.32 531 2 7
8 13 45.64 5 14.35 479 2 6
9 8 0.20 240 13.95 383 2 15

Cycle 1 GMT 2/ 5/2016 5:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 23 14.38 506 2 3
2 3 855.76 -3 14.38 506 2 3
3 3 913.56 -2 14.38 506 2 3
4 7 955.80 74 12.99 1709 3 4
5 8 -0.16 240 13.93 381 2 16

Cycle 0 GMT 1/ 5/2016 18: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.68 23 14.44 403 2 2
2 7 69.72 74 14.18 407 2 2
3 8 0.40 240 14.18 314 2 21