SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8630 WMO= 7900683


Cycle 259 GMT 7/ 3/2024 19:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 32 14.82 530 3 3
2 10 1015.40 3 14.65 1799 3 3
3 3 955.24 -1 15.31 0 3 3
4 12 1174.76 4 14.71 1979 3 3
5 7 2002.04 33 14.17 2892 3 3
6 13 1642.68 27 14.23 2463 3 3
7 13 842.92 27 14.53 1467 3 3
8 13 105.20 27 14.85 527 3 3
9 8 -0.12 180 14.86 362 3 5

Cycle 258 GMT 27/ 2/2024 0:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 33 14.78 522 3 3
2 12 1167.00 4 14.68 1977 3 3
3 7 1525.24 33 14.45 2323 3 3
4 13 1484.12 27 14.42 2283 3 3
5 13 686.68 27 14.68 1278 3 3
6 13 28.76 27 14.98 447 3 3
7 8 0.08 180 14.93 377 3 5

Cycle 257 GMT 26/ 2/2024 3:53: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 33 14.73 516 3 3
2 12 1174.72 4 14.66 1935 3 3
3 7 1506.08 33 14.44 2316 3 3
4 13 1466.72 27 14.43 2252 3 3
5 13 728.48 27 14.67 1339 3 3
6 13 42.64 27 14.97 457 3 3
7 8 0.08 180 14.93 372 3 4

Cycle 256 GMT 25/ 2/2024 6:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 33 14.72 522 3 3
2 12 1168.68 4 14.68 1913 3 3
3 7 1506.08 33 14.43 2281 3 3
4 13 1467.48 27 14.42 2239 3 3
5 13 740.04 27 14.65 1356 3 3
6 8 0.16 180 14.94 365 3 7

Cycle 255 GMT 24/ 2/2024 9:24: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 26 14.75 511 3 3
2 10 1040.56 6 14.45 1836 3 3
3 3 1049.28 1 14.80 1826 3 3
4 12 1183.44 4 14.73 1979 3 3
5 7 2006.44 33 14.17 2913 3 3
6 13 1650.08 27 14.23 2499 3 3
7 13 853.28 27 14.52 1483 3 3
8 13 70.84 27 14.87 492 3 3
9 8 -0.12 180 14.86 363 3 5

Cycle 254 GMT 14/ 2/2024 14:21: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 26 14.81 520 3 3
2 12 1180.16 4 14.72 1973 3 3
3 7 2002.16 33 14.17 2900 3 3
4 13 1695.04 27 14.23 2543 3 3
5 13 891.08 27 14.51 1546 3 3
6 13 157.76 27 14.83 588 3 3
7 8 -0.24 180 14.86 365 3 14
8 14 -0.24 25 14.85 372 3 3

Cycle 253

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 26 14.82 539 3 3
2 12 1178.44 4 14.72 1945 3 3
3 7 2003.24 33 14.16 2909 3 3
4 13 1651.40 27 14.25 2478 3 3
5 13 903.64 27 14.51 1545 3 3
6 13 115.92 7 14.93 559 3 3

Cycle 252

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 27 14.81 517 3 3
2 12 1155.56 4 14.73 1889 3 3
3 7 2002.32 33 14.16 2898 3 3
4 13 1644.08 27 14.24 2461 3 3
5 13 843.68 27 14.53 1457 3 3
6 13 65.20 6 14.95 489 3 3

Cycle 251

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 27 14.81 528 3 3
2 12 1159.28 4 14.70 1954 3 3
3 7 2006.76 33 14.18 2902 3 3
4 13 1696.60 27 14.23 2530 3 3
5 13 892.12 27 14.51 1530 3 3
6 13 99.24 6 14.94 538 3 3

Cycle 250

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 14.81 517 3 3
2 3 880.72 -2 15.28 0 3 3
3 3 954.12 -1 15.32 0 3 3
4 12 1182.48 4 14.72 1949 3 3
5 7 2002.12 33 14.17 2904 3 3
6 13 1651.80 27 14.24 2483 3 3
7 13 906.92 27 14.50 1558 3 3
8 13 66.60 6 14.95 492 3 3

Cycle 249

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 26 14.81 561 3 3
2 10 1047.76 5 14.51 1781 3 3
3 12 1168.44 4 14.73 1957 3 3
4 7 2006.12 33 14.16 2910 3 3
5 13 1690.72 27 14.23 2534 3 3
6 13 882.04 27 14.51 1528 3 3
7 13 99.44 6 14.93 547 3 3

Cycle 248

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 31 14.81 517 3 3
2 3 834.76 -3 15.28 0 3 3
3 3 931.68 -1 15.32 0 3 3
4 12 1135.64 4 14.73 1909 3 3
5 7 2002.36 33 14.17 2929 3 3
6 13 1647.40 27 14.25 2465 3 3
7 13 847.92 27 14.54 1482 3 3
8 13 45.20 5 14.98 477 3 3

Cycle 247

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 32 14.81 531 3 3
2 3 956.60 -1 15.28 0 3 3
3 12 1164.64 4 14.71 1919 3 3
4 7 2008.04 33 14.16 2928 3 3
5 13 1704.68 27 14.22 2539 3 3
6 13 842.28 27 14.54 1495 3 3
7 13 117.60 7 14.93 564 3 3

Cycle 246

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 27 14.82 540 3 3
2 10 1022.36 6 14.50 1793 3 3
3 3 1022.96 1 14.93 1784 3 3
4 12 1171.96 4 14.72 1990 3 3
5 7 2002.96 33 14.16 2905 3 3
6 13 1696.64 27 14.23 2543 3 3
7 13 881.32 27 14.52 1524 3 3
8 13 145.60 8 14.89 600 3 3

Cycle 245

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 30 14.83 505 3 3
2 3 875.00 -2 15.29 0 3 3
3 3 940.72 -1 15.33 0 3 3
4 12 1138.16 4 14.74 1876 3 3
5 7 2001.96 33 14.17 2899 3 3
6 13 1646.68 27 14.24 2468 3 3
7 13 855.20 27 14.53 1479 3 3
8 13 126.60 7 14.93 568 3 3

Cycle 244

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 26 14.81 560 3 3
2 10 1051.00 4 14.53 1778 3 3
3 12 1174.92 4 14.72 1968 3 3
4 7 2002.48 33 14.18 2892 3 3
5 13 1641.76 27 14.25 2469 3 3
6 13 835.92 27 14.54 1456 3 3
7 13 95.12 6 14.95 526 3 3

Cycle 243

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.82 524 3 3
2 3 877.20 -2 15.29 0 3 3
3 3 947.88 -1 15.33 0 3 3
4 12 1151.16 4 14.71 1983 3 3
5 7 2005.76 33 14.17 2871 3 3
6 13 1651.16 27 14.25 2467 3 3
7 13 851.12 27 14.53 1471 3 3
8 13 73.64 6 14.95 500 3 3

Cycle 242

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 26 14.81 547 3 3
2 10 1046.96 5 14.55 1776 3 3
3 12 1178.16 4 14.73 1959 3 3
4 7 2002.36 33 14.18 2893 3 3
5 13 1646.00 27 14.25 2447 3 3
6 13 844.32 27 14.53 1487 3 3
7 13 105.48 7 14.93 549 3 3

Cycle 241

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 30 14.81 542 3 3
2 3 885.60 -2 15.29 0 3 3
3 3 952.60 -1 15.33 0 3 3
4 12 1165.36 4 14.71 1989 3 3
5 7 2002.64 33 14.18 2906 3 3
6 13 1637.88 27 14.25 2451 3 3
7 13 885.48 27 14.52 1523 3 3
8 13 137.08 7 14.93 584 3 3

Cycle 240

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 27 14.82 540 3 3
2 10 1039.96 3 14.59 1769 3 3
3 12 1155.04 4 14.73 1948 3 3
4 7 2001.92 33 14.17 2900 3 3
5 13 1640.56 27 14.25 2470 3 3
6 13 782.44 27 14.56 1397 3 3
7 13 66.88 6 14.95 518 3 3

Cycle 239

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 27 14.81 562 3 3
2 3 1022.56 1 14.92 1806 3 3
3 12 1171.64 4 14.71 1959 3 3
4 7 2003.04 33 14.17 2914 3 3
5 13 1701.96 27 14.23 2516 3 3
6 13 882.24 27 14.53 1495 3 3
7 13 142.12 7 14.93 571 3 3
8 13 46.16 5 14.98 478 3 3

Cycle 238

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 27 14.80 558 3 3
2 12 1161.64 4 14.73 1978 3 3
3 7 2007.52 33 14.16 2929 3 3
4 13 1648.48 27 14.24 2462 3 3
5 13 837.44 27 14.54 1473 3 3
6 13 83.20 6 14.95 523 3 3
7 13 41.36 5 14.98 493 3 3

Cycle 237

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 31 14.82 530 3 3
2 3 873.08 -2 15.29 0 3 3
3 3 944.04 -1 15.33 0 3 3
4 12 1153.56 4 14.73 1943 3 3
5 7 2007.04 33 14.17 2896 3 3
6 13 1590.24 27 14.26 2413 3 3
7 13 792.20 27 14.55 1412 3 3
8 13 144.08 8 14.89 602 3 3

Cycle 236

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 30 14.81 532 3 3
2 3 1030.56 1 14.85 1802 3 3
3 12 1175.60 4 14.69 1954 3 3
4 7 2002.44 33 14.17 2899 3 3
5 13 1597.28 27 14.27 2404 3 3
6 13 792.48 27 14.56 1396 3 3
7 13 122.12 7 14.93 572 3 3
8 13 44.40 5 14.97 494 3 3

Cycle 235

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 30 14.80 575 3 3
2 3 1022.48 1 14.93 1769 3 3
3 12 1165.40 4 14.70 1934 3 3
4 7 2007.20 33 14.19 2896 3 3
5 13 1648.48 27 14.24 2481 3 3
6 13 893.64 27 14.52 1542 3 3
7 13 156.24 8 14.90 612 3 3

Cycle 234

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 26 14.81 555 3 3
2 10 1039.72 4 14.52 1783 3 3
3 12 1170.80 4 14.72 1945 3 3
4 7 2006.08 33 14.18 2899 3 3
5 13 1701.20 27 14.23 2542 3 3
6 13 836.04 27 14.54 1470 3 3
7 13 49.76 5 14.99 488 3 3

Cycle 233

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 26 14.83 537 3 3
2 12 1160.76 4 14.71 1964 3 3
3 7 2006.92 33 14.15 2912 3 3
4 13 1642.88 27 14.23 2487 3 3
5 13 822.16 27 14.54 1464 3 3
6 13 130.24 7 14.93 596 3 3
7 13 57.00 5 14.98 508 3 3

Cycle 232

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 26 14.82 524 3 3
2 12 1175.04 4 14.70 1953 3 3
3 7 2003.44 33 14.18 2894 3 3
4 13 1748.24 27 14.23 2583 3 3
5 13 858.96 27 14.54 1471 3 3
6 13 119.28 7 14.94 558 3 3

Cycle 231

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 26 14.83 517 3 3
2 3 1030.36 1 14.91 1802 3 3
3 12 1168.76 4 14.71 1940 3 3
4 7 2005.40 33 14.19 2895 3 3
5 13 1697.20 27 14.23 2560 3 3
6 13 839.92 27 14.54 1473 3 3
7 13 109.88 7 14.94 554 3 3

Cycle 230

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 27 14.84 502 3 3
2 3 968.72 -1 15.30 0 3 3
3 12 1177.08 4 14.72 1989 3 3
4 7 2002.00 33 14.18 2886 3 3
5 13 1686.60 27 14.24 2517 3 3
6 13 818.92 27 14.55 1449 3 3
7 13 50.52 5 14.98 498 3 3

Cycle 229

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 30 14.83 509 3 3
2 3 882.72 -2 15.30 0 3 3
3 3 957.48 -1 15.34 0 3 3
4 12 1181.12 4 14.69 1962 3 3
5 7 2005.84 33 14.17 2910 3 3
6 13 1696.12 27 14.23 2556 3 3
7 13 833.32 27 14.56 1442 3 3
8 13 101.76 6 14.95 539 3 3

Cycle 228

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 27 14.82 535 3 3
2 10 1040.52 3 14.62 1810 3 3
3 12 1160.08 4 14.73 1912 3 3
4 7 2001.96 33 14.18 2918 3 3
5 13 1698.16 27 14.25 2517 3 3
6 13 828.76 27 14.55 1436 3 3
7 13 106.36 7 14.95 538 3 3

Cycle 227

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 31 14.82 508 3 3
2 3 857.56 -3 15.29 0 3 3
3 12 1168.76 4 14.72 2001 3 3
4 7 2002.52 33 14.17 2915 3 3
5 13 1747.48 27 14.19 2611 3 3
6 13 849.32 27 14.54 1474 3 3
7 13 85.92 6 14.95 517 3 3

Cycle 226

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 27 14.81 541 3 3
2 10 1046.60 5 14.53 1826 3 3
3 12 1170.32 4 14.68 1979 3 3
4 7 2006.28 34 14.16 2914 3 3
5 13 1598.88 27 14.25 2415 3 3
6 13 867.20 27 14.52 1500 3 3
7 13 177.24 8 14.88 632 3 3

Cycle 225

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 26 14.80 554 3 3
2 3 1044.52 1 14.81 1897 3 3
3 12 1178.64 4 14.69 2001 3 3
4 7 2003.12 34 14.16 2912 3 3
5 13 1642.00 27 14.25 2473 3 3
6 13 835.76 27 14.54 1467 3 3
7 13 157.64 8 14.89 624 3 3

Cycle 224

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 14.82 537 3 3
2 3 860.36 -3 15.29 0 3 3
3 3 957.08 -1 15.34 0 3 3
4 12 1178.24 4 14.69 1991 3 3
5 7 2005.72 33 14.17 2924 3 3
6 13 1641.56 27 14.25 2464 3 3
7 13 893.40 27 14.51 1530 3 3
8 13 108.16 7 14.94 553 3 3

Cycle 223

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 26 14.81 540 3 3
2 10 1053.44 5 14.51 1868 3 3
3 3 1031.36 1 14.88 1806 3 3
4 12 1171.00 4 14.71 2005 3 3
5 7 2002.88 33 14.16 2911 3 3
6 13 1697.32 27 14.23 2537 3 3
7 13 835.32 27 14.54 1464 3 3
8 13 102.60 6 14.94 552 3 3

Cycle 222

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 32 14.83 516 3 3
2 3 806.32 -4 15.30 0 3 3
3 3 952.20 -1 15.34 0 3 3
4 12 1167.72 4 14.70 1932 3 3
5 7 2008.40 33 14.16 2912 3 3
6 13 1755.84 27 14.21 2609 3 3
7 13 849.20 27 14.53 1500 3 3
8 13 67.96 6 14.96 495 3 3

Cycle 221

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 33 14.82 529 3 3
2 3 952.28 -1 15.30 0 3 3
3 12 1169.04 4 14.71 1984 3 3
4 7 2006.48 34 14.16 2912 3 3
5 13 1592.24 27 14.25 2402 3 3
6 13 789.04 27 14.55 1405 3 3
7 13 51.00 5 14.99 502 3 3

Cycle 220

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 34 14.75 532 3 3
2 12 1156.96 4 14.74 1966 3 3
3 7 2007.52 33 14.18 2898 3 3
4 13 1650.00 27 14.24 2469 3 3
5 13 893.44 27 14.52 1526 3 3
6 13 110.60 7 14.95 556 3 3

Cycle 219 GMT 9/ 3/2023 4: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 34 14.82 531 3 3
2 12 1161.56 4 14.72 1971 3 3
3 7 2002.36 33 14.18 2913 3 3
4 13 1628.40 27 14.24 2452 3 3
5 13 819.32 27 14.54 1435 3 3
6 13 42.36 27 14.91 441 3 3
7 8 0.12 180 14.87 368 3 3
8 14 0.12 25 14.86 383 3 7

Cycle 218 GMT 27/ 2/2023 9: 0: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 34 14.82 535 3 3
2 12 1150.24 4 14.68 1896 3 3
3 7 1522.44 33 14.42 2321 3 3
4 13 1381.40 27 14.47 2138 3 3
5 13 653.76 27 14.70 1240 3 3
6 13 19.00 27 14.99 421 3 3
7 8 0.20 180 14.94 367 3 5

Cycle 217 GMT 26/ 2/2023 12:11: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 34 14.71 531 3 3
2 12 1164.80 4 14.68 1937 3 3
3 7 1507.80 33 14.45 2303 3 3
4 13 1382.24 27 14.45 2151 3 3
5 13 664.00 27 14.69 1260 3 3
6 13 25.08 27 14.98 432 3 3
7 8 0.36 180 14.94 370 3 4

Cycle 216 GMT 25/ 2/2023 15:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 34 14.70 519 3 3
2 12 1176.40 4 14.66 1994 3 3
3 7 1511.32 34 14.43 2302 3 3
4 13 1384.40 27 14.46 2144 3 3
5 13 502.16 27 14.76 1038 3 3
6 8 -0.56 180 14.94 371 3 6

Cycle 215

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 33 14.70 532 3 3
2 12 1166.96 4 14.65 1957 3 3
3 7 1525.08 33 14.42 2314 3 3
4 13 1393.88 27 14.45 2178 3 3
5 13 688.00 27 14.68 1273 3 3
6 13 23.28 27 14.97 438 3 3
7 8 0.64 180 14.93 366 3 5
8 14 0.64 25 14.92 372 3 7

Cycle 214 GMT 23/ 2/2023 19:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 14.69 532 3 3
2 10 1007.84 6 14.45 1788 3 3
3 12 1161.80 4 14.66 1957 3 3
4 7 1522.00 33 14.43 2316 3 3
5 13 1378.72 27 14.44 2144 3 3
6 13 661.92 27 14.69 1258 3 3
7 13 23.88 27 14.97 426 3 3
8 8 -0.04 180 14.92 374 3 5

Cycle 213 GMT 22/ 2/2023 20: 3: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 29 14.71 516 3 3
2 10 1008.04 6 14.44 1726 3 3
3 12 1176.04 4 14.70 1950 3 3
4 7 2002.52 34 14.16 2918 3 3
5 13 1521.60 27 14.27 2341 3 3
6 13 646.92 27 14.62 1222 3 3
7 13 29.80 27 14.91 436 3 3
8 8 -0.24 180 14.87 372 3 5

Cycle 212

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 29 14.81 552 3 3
2 12 1162.56 4 14.70 1959 3 3
3 7 2002.80 33 14.17 2930 3 3
4 13 1523.12 27 14.27 2343 3 3
5 13 797.44 27 14.53 1427 3 3
6 13 43.92 27 14.90 456 3 3
7 8 1.56 180 14.85 387 3 8
8 14 1.56 25 14.84 402 3 6

Cycle 211

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 29 14.81 560 3 3
2 12 1177.28 4 14.70 1989 3 3
3 7 2007.00 33 14.15 2945 3 3
4 13 1525.32 27 14.27 2347 3 3
5 13 788.28 27 14.55 1419 3 3
6 13 57.96 5 14.99 501 3 3

Cycle 210

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 29 14.82 516 3 3
2 12 1167.08 4 14.70 1969 3 3
3 7 2007.32 33 14.18 2929 3 3
4 13 1526.08 27 14.29 2347 3 3
5 13 800.88 27 14.55 1427 3 3
6 13 57.00 5 14.99 493 3 3

Cycle 209

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 29 14.80 540 3 3
2 3 1020.16 1 14.98 1853 3 3
3 12 1166.20 4 14.72 1985 3 3
4 7 2001.96 34 14.17 2897 3 3
5 13 1513.84 27 14.28 2311 3 3
6 13 643.16 27 14.61 1228 3 3

Cycle 208

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 29 14.82 536 3 3
2 12 1170.00 4 14.70 1936 3 3
3 7 2002.52 33 14.16 2897 3 3
4 13 1669.64 27 14.22 2506 3 3
5 13 765.00 27 14.56 1367 3 3
6 13 86.96 6 14.94 541 3 3

Cycle 207

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 29 14.81 552 3 3
2 12 1175.96 4 14.72 1996 3 3
3 7 2002.48 34 14.16 2906 3 3
4 13 1509.20 27 14.28 2313 3 3
5 13 763.92 27 14.55 1385 3 3
6 13 51.48 5 14.99 505 3 3

Cycle 206

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 29 14.82 546 3 3
2 12 1173.08 4 14.74 1990 3 3
3 7 2001.76 33 14.18 2909 3 3
4 13 1518.80 27 14.27 2307 3 3
5 13 789.84 27 14.56 1400 3 3
6 13 55.56 5 15.00 497 3 3

Cycle 205

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 14.83 527 3 3
2 12 1172.12 4 14.69 2027 3 3
3 7 2002.40 33 14.19 2893 3 3
4 13 1525.52 27 14.29 2318 3 3
5 13 797.96 27 14.56 1409 3 3
6 13 55.76 5 15.00 487 3 3

Cycle 204

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 28 14.82 547 3 3
2 12 1171.72 4 14.74 1927 3 3
3 7 2006.68 33 14.17 2902 3 3
4 13 1525.16 27 14.28 2308 3 3
5 13 790.20 27 14.56 1392 3 3
6 13 54.72 5 15.00 485 3 3

Cycle 203

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 28 14.82 541 3 3
2 12 1162.00 4 14.71 1918 3 3
3 7 2002.24 33 14.17 2907 3 3
4 13 1524.56 27 14.28 2328 3 3
5 13 794.88 27 14.55 1409 3 3
6 13 57.36 5 15.00 503 3 3

Cycle 202

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 27 14.82 527 3 3
2 10 1013.52 3 14.66 1789 3 3
3 3 950.00 -1 15.36 0 3 3
4 12 1153.44 4 14.73 1963 3 3
5 7 2007.20 34 14.16 2932 3 3
6 13 1514.80 27 14.28 2339 3 3
7 13 771.76 27 14.56 1389 3 3

Cycle 201

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.84 510 3 3
2 3 963.92 -1 15.36 0 3 3
3 12 1165.28 4 14.70 2005 3 3
4 7 2005.76 33 14.18 2908 3 3
5 13 1521.72 27 14.28 2318 3 3
6 13 791.44 27 14.56 1407 3 3
7 13 57.12 5 15.00 501 3 3

Cycle 200

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 27 14.84 531 3 3
2 3 1049.32 1 14.87 1876 3 3
3 12 1178.60 4 14.67 2006 3 3
4 7 2003.24 34 14.17 2918 3 3
5 13 1511.92 27 14.30 2294 3 3
6 13 776.52 27 14.57 1375 3 3

Cycle 199

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.82 542 3 3
2 3 972.44 -1 15.36 0 3 3
3 12 1173.84 4 14.72 1988 3 3
4 7 2006.00 34 14.18 2925 3 3
5 13 1516.36 27 14.28 2316 3 3
6 13 638.00 27 14.63 1207 3 3
7 13 47.28 5 15.00 484 3 3

Cycle 198

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 27 14.83 531 3 3
2 10 1018.48 3 14.63 1771 3 3
3 3 956.48 -1 15.36 0 3 3
4 12 1163.00 4 14.74 1985 3 3
5 7 2008.32 33 14.19 2909 3 3
6 13 1507.84 27 14.30 2296 3 3
7 13 766.24 27 14.57 1379 3 3

Cycle 197

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 30 14.84 515 3 3
2 3 931.28 -1 15.36 0 3 3
3 3 962.52 -1 15.39 0 3 3
4 12 1164.04 4 14.72 1991 3 3
5 7 2006.00 33 14.20 2891 3 3
6 13 1527.64 27 14.28 2342 3 3
7 13 797.64 27 14.56 1405 3 3
8 13 59.28 5 15.01 496 3 3

Cycle 196

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 29 14.83 543 3 3
2 10 1019.20 3 14.61 1782 3 3
3 3 955.96 -1 15.36 0 3 3
4 12 1161.32 4 14.71 2025 3 3
5 7 2007.64 33 14.18 2910 3 3
6 13 1508.88 27 14.30 2291 3 3
7 13 773.88 27 14.57 1382 3 3

Cycle 195

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 14.82 537 3 3
2 3 1018.60 1 14.99 1800 3 3
3 12 1169.08 4 14.71 1993 3 3
4 7 2008.20 33 14.18 2917 3 3
5 13 1523.40 27 14.30 2312 3 3
6 13 654.60 27 14.62 1220 3 3
7 13 59.36 5 15.00 486 3 3
8 13 48.16 5 15.00 470 3 3

Cycle 194

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 28 14.84 543 3 3
2 12 1165.08 4 14.72 1994 3 3
3 7 2007.28 33 14.18 2927 3 3
4 13 1515.08 27 14.30 2334 3 3
5 13 788.16 27 14.56 1410 3 3
6 13 86.76 6 14.96 527 3 3

Cycle 193

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 28 14.83 529 3 3
2 3 1025.40 1 14.98 1869 3 3
3 12 1176.00 4 14.68 2005 3 3
4 7 2007.40 33 14.19 2915 3 3
5 13 1524.68 27 14.29 2311 3 3
6 13 650.20 27 14.63 1215 3 3

Cycle 192

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 29 14.83 556 3 3
2 3 966.24 -1 15.37 0 3 3
3 12 1163.36 4 14.71 2013 3 3
4 7 2004.36 33 14.19 2908 3 3
5 13 1523.04 27 14.30 2328 3 3
6 13 799.20 27 14.56 1414 3 3
7 13 57.44 5 15.00 482 3 3

Cycle 191

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 29 14.82 554 3 3
2 12 1167.80 4 14.73 1976 3 3
3 7 2005.72 33 14.17 2915 3 3
4 13 1517.88 27 14.30 2299 3 3
5 13 634.64 27 14.63 1203 3 3

Cycle 190

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 14.83 532 3 3
2 12 1168.32 4 14.71 1949 3 3
3 7 2004.12 33 14.18 2909 3 3
4 13 1513.84 27 14.29 2327 3 3
5 13 786.76 27 14.55 1419 3 3
6 13 55.52 5 15.01 500 3 3

Cycle 189

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 14.84 518 3 3
2 12 1172.24 4 14.72 1985 3 3
3 7 2005.04 33 14.20 2902 3 3
4 13 1514.16 27 14.30 2292 3 3
5 13 771.40 27 14.57 1368 3 3
6 13 79.16 6 14.97 513 3 3

Cycle 188

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 28 14.83 558 3 3
2 12 1155.24 4 14.73 1940 3 3
3 7 2003.36 33 14.19 2909 3 3
4 13 1502.28 27 14.29 2322 3 3
5 13 764.00 27 14.58 1383 3 3
6 13 75.76 6 14.98 505 3 3

Cycle 187

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 28 14.83 545 3 3
2 3 1021.68 1 15.01 1805 3 3
3 12 1168.68 4 14.73 1899 3 3
4 7 2006.52 33 14.19 2900 3 3
5 13 1513.80 27 14.31 2325 3 3
6 13 635.24 27 14.63 1221 3 3

Cycle 186

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 14.84 526 3 3
2 12 1149.24 4 14.74 1966 3 3
3 7 2007.12 33 14.20 2929 3 3
4 13 1519.72 27 14.31 2310 3 3
5 13 783.32 27 14.57 1405 3 3
6 13 45.12 5 15.01 492 3 3

Cycle 185

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 29 14.82 570 3 3
2 3 963.96 -1 15.37 0 3 3
3 12 1166.12 4 14.71 1965 3 3
4 7 2007.84 33 14.19 2923 3 3
5 13 1518.12 27 14.30 2311 3 3
6 13 785.56 27 14.57 1399 3 3
7 13 54.04 5 15.00 492 3 3

Cycle 184

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 29 14.83 542 3 3
2 10 1006.56 3 14.68 1776 3 3
3 3 946.60 -1 15.37 0 3 3
4 12 1143.12 4 14.75 1923 3 3
5 7 2005.72 33 14.20 2894 3 3
6 13 1526.24 27 14.29 2326 3 3
7 13 644.92 27 14.64 1218 3 3
8 13 46.12 5 15.01 473 3 3

Cycle 183

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 14.83 544 3 3
2 12 1172.84 4 14.72 1946 3 3
3 7 2007.68 33 14.21 2899 3 3
4 13 1518.80 27 14.31 2316 3 3
5 13 776.24 27 14.58 1376 3 3
6 13 55.20 5 15.01 484 3 3
7 13 46.84 5 15.01 501 3 3

Cycle 182

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 29 14.84 525 3 3
2 12 1162.60 4 14.73 1955 3 3
3 7 2005.16 33 14.20 2905 3 3
4 13 1526.20 27 14.30 2305 3 3
5 13 780.88 27 14.58 1390 3 3
6 13 55.56 5 15.01 494 3 3

Cycle 181

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 29 14.82 569 3 3
2 12 1162.40 4 14.72 1988 3 3
3 7 2003.88 33 14.20 2905 3 3
4 13 1517.92 27 14.32 2329 3 3
5 13 780.08 27 14.57 1416 3 3
6 13 54.64 5 15.01 490 3 3

Cycle 180

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 29 14.84 552 3 3
2 12 1182.12 4 14.73 2010 3 3
3 7 2005.56 34 14.19 2909 3 3
4 13 1501.00 27 14.31 2304 3 3
5 13 757.80 27 14.58 1361 3 3
6 13 51.72 5 15.01 493 3 3

Cycle 179

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 27 14.85 537 3 3
2 10 1002.88 4 14.61 1717 3 3
3 3 953.28 -1 15.37 0 3 3
4 12 1153.32 4 14.74 1908 3 3
5 7 2004.40 33 14.21 2904 3 3
6 13 1514.60 27 14.31 2322 3 3
7 13 774.04 27 14.59 1395 3 3
8 13 53.08 5 15.01 503 3 3

Cycle 178

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 32 14.90 532 3 3
2 3 815.80 -3 15.40 0 3 3
3 3 911.08 -2 15.43 0 3 3
4 12 1166.64 4 14.75 1952 3 3
5 7 2003.64 33 14.21 2899 3 3
6 13 1520.88 27 14.30 2300 3 3
7 13 655.12 27 14.65 1220 3 3
8 13 59.96 5 15.02 493 3 3

Cycle 177

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 33 14.88 555 3 3
2 3 828.28 -3 15.41 0 3 3
3 3 927.12 -1 15.44 0 3 3
4 12 1143.40 4 14.72 1969 3 3
5 7 1523.52 33 14.46 2337 3 3
6 13 1380.52 27 14.48 2164 3 3
7 13 480.96 27 14.79 1004 3 3

Cycle 176

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 33 14.77 527 3 3
2 12 1161.56 4 14.71 1974 3 3
3 7 1505.92 33 14.47 2302 3 3
4 13 1373.52 27 14.48 2161 3 3
5 13 490.40 27 14.79 1023 3 3
6 13 41.12 5 15.08 475 3 3

Cycle 175

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 33 14.76 539 3 3
2 12 1170.56 4 14.71 1962 3 3
3 7 1524.44 33 14.47 2302 3 3
4 13 1384.96 27 14.48 2152 3 3
5 13 647.40 27 14.72 1213 3 3
6 13 20.76 27 15.00 417 3 3
7 8 0.44 180 14.96 361 3 4
8 14 0.44 25 14.95 373 3 5

Cycle 174 GMT 28/ 2/2022 7:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 33 14.73 535 3 3
2 12 1168.44 4 14.70 2024 3 3
3 7 1526.60 34 14.45 2364 3 3
4 13 1386.80 27 14.48 2144 3 3
5 13 492.76 27 14.77 1045 3 3
6 8 0.20 180 14.96 372 3 4

Cycle 173 GMT 27/ 2/2022 8:14: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 32 14.76 527 3 3
2 3 1049.64 1 14.91 1850 3 3
3 12 1174.20 4 14.72 2007 3 3
4 7 1506.76 34 14.45 2319 3 3
5 13 1371.84 27 14.48 2155 3 3
6 13 478.52 27 14.78 999 3 3
7 13 23.56 27 14.99 427 3 3
8 8 -0.12 180 14.94 371 3 4

Cycle 172 GMT 26/ 2/2022 9:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 14.74 529 3 3
2 10 1019.84 6 14.49 1801 3 3
3 12 1162.68 4 14.71 1971 3 3
4 7 1526.16 33 14.44 2315 3 3
5 13 1388.92 27 14.47 2159 3 3
6 13 658.24 27 14.69 1233 3 3
7 13 22.88 27 14.99 419 3 3
8 8 0.00 180 14.94 373 3 5

Cycle 171 GMT 25/ 2/2022 10:20: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 14.76 526 3 3
2 10 1055.56 5 14.52 1814 3 3
3 12 1175.48 4 14.77 1928 3 3
4 7 2003.64 33 14.21 2913 3 3
5 13 1519.96 27 14.31 2325 3 3
6 13 627.40 27 14.65 1197 3 3
7 13 24.60 27 14.94 421 3 3
8 8 -0.08 180 14.90 369 3 4

Cycle 170

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 14.84 555 3 3
2 12 1170.32 4 14.74 1988 3 3
3 7 2005.36 33 14.20 2938 3 3
4 13 1520.68 27 14.31 2313 3 3
5 13 637.56 27 14.64 1216 3 3
6 13 26.24 27 14.93 433 3 3
7 8 2.20 180 14.88 379 3 5
8 14 2.20 25 14.87 389 3 5

Cycle 169

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 28 14.84 539 3 3
2 10 1000.64 3 14.72 1776 3 3
3 3 948.08 -1 15.38 0 3 3
4 12 1153.48 4 14.73 1965 3 3
5 7 2004.00 33 14.20 2935 3 3
6 13 1509.12 27 14.30 2321 3 3
7 13 762.08 27 14.58 1373 3 3

Cycle 168

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 14.83 569 3 3
2 12 1175.56 4 14.77 1969 3 3
3 7 2005.76 33 14.21 2899 3 3
4 13 1517.12 27 14.30 2327 3 3
5 13 783.76 27 14.58 1389 3 3
6 13 54.16 5 15.02 492 3 3

Cycle 167

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 28 14.84 539 3 3
2 12 1156.68 4 14.73 1926 3 3
3 7 2003.64 33 14.20 2905 3 3
4 13 1516.68 27 14.30 2331 3 3
5 13 784.04 27 14.58 1397 3 3

Cycle 166

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 28 14.85 545 3 3
2 12 1159.04 4 14.78 1943 3 3
3 7 2004.56 33 14.20 2936 3 3
4 13 1514.80 27 14.31 2323 3 3
5 13 645.12 27 14.64 1232 3 3

Cycle 165

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 28 14.83 564 3 3
2 12 1174.32 4 14.70 2001 3 3
3 7 2005.40 33 14.21 2907 3 3
4 13 1514.96 27 14.32 2304 3 3
5 13 772.84 27 14.59 1385 3 3

Cycle 164

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 14.84 546 3 3
2 12 1159.60 4 14.74 1969 3 3
3 7 2004.76 33 14.23 2891 3 3
4 13 1508.56 27 14.33 2295 3 3
5 13 770.36 27 14.58 1383 3 3

Cycle 163

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 28 14.84 547 3 3
2 12 1163.08 4 14.74 1921 3 3
3 7 2006.84 34 14.21 2896 3 3
4 13 1506.68 27 14.34 2285 3 3
5 13 617.16 27 14.66 1171 3 3

Cycle 162

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 28 14.85 518 3 3
2 12 1173.28 4 14.76 1979 3 3
3 7 2005.48 33 14.20 2908 3 3
4 13 1507.20 27 14.33 2296 3 3
5 13 623.44 27 14.66 1184 3 3

Cycle 161

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 28 14.85 517 3 3
2 12 1150.56 4 14.73 2019 3 3
3 7 2005.56 33 14.20 2923 3 3
4 13 1513.24 27 14.32 2314 3 3
5 13 766.68 27 14.58 1364 3 3

Cycle 160

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 28 14.85 525 3 3
2 12 1155.36 4 14.74 1964 3 3
3 7 2003.48 33 14.20 2920 3 3
4 13 1515.76 27 14.31 2318 3 3
5 13 637.36 27 14.65 1206 3 3

Cycle 159

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 14.84 557 3 3
2 3 1031.60 1 14.97 1844 3 3
3 12 1173.32 4 14.75 1972 3 3
4 7 2005.24 33 14.20 2912 3 3
5 13 1518.00 27 14.32 2306 3 3
6 13 634.92 27 14.65 1205 3 3

Cycle 158

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 14.85 525 3 3
2 12 1180.64 4 14.72 1972 3 3
3 7 2004.08 33 14.21 2899 3 3
4 13 1513.84 27 14.31 2324 3 3
5 13 637.12 27 14.64 1219 3 3
6 13 46.80 5 15.01 492 3 3

Cycle 157

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 29 14.85 517 3 3
2 3 963.16 -1 15.38 0 3 3
3 12 1164.28 4 14.71 2051 3 3
4 7 2004.64 33 14.20 2894 3 3
5 13 1518.16 27 14.32 2319 3 3
6 13 640.84 27 14.64 1208 3 3

Cycle 156

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 28 14.83 553 3 3
2 10 1036.64 3 14.62 1849 3 3
3 3 970.04 -1 15.38 0 3 3
4 12 1169.88 4 14.72 2035 3 3
5 7 2003.32 33 14.21 2908 3 3
6 13 1508.68 27 14.32 2313 3 3
7 13 769.20 27 14.58 1377 3 3

Cycle 155

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 27 14.83 560 3 3
2 12 1169.76 4 14.76 1939 3 3
3 7 2003.56 33 14.20 2901 3 3
4 13 1513.60 27 14.30 2340 3 3
5 13 621.88 27 14.64 1207 3 3
6 13 61.88 5 15.01 522 3 3

Cycle 154

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 14.85 521 3 3
2 3 971.04 -1 15.38 0 3 3
3 12 1169.12 4 14.75 1981 3 3
4 7 2004.76 33 14.21 2908 3 3
5 13 1525.44 27 14.31 2328 3 3
6 13 645.20 27 14.64 1219 3 3

Cycle 153

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 14.84 540 3 3
2 10 1004.08 3 14.63 1794 3 3
3 3 927.36 -1 15.38 0 3 3
4 3 960.12 -1 15.41 0 3 3
5 12 1160.88 4 14.70 1964 3 3
6 7 2003.20 33 14.22 2897 3 3
7 13 1498.96 27 14.33 2283 3 3
8 13 762.84 27 14.59 1370 3 3

Cycle 152

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 28 14.84 536 3 3
2 12 1168.12 4 14.73 1937 3 3
3 7 2001.96 33 14.21 2915 3 3
4 13 1510.00 27 14.32 2338 3 3
5 13 623.44 27 14.66 1185 3 3
6 13 45.80 5 15.02 488 3 3

Cycle 151

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 28 14.85 534 3 3
2 12 1171.52 4 14.74 2001 3 3
3 7 2003.36 33 14.19 2928 3 3
4 13 1502.68 27 14.31 2310 3 3
5 13 613.52 27 14.66 1190 3 3

Cycle 150

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 14.83 575 3 3
2 12 1166.24 4 14.76 2000 3 3
3 7 2003.04 34 14.21 2896 3 3
4 13 1497.84 27 14.33 2285 3 3
5 13 603.80 27 14.66 1173 3 3

Cycle 149

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 28 14.84 551 3 3
2 12 1157.92 4 14.73 2028 3 3
3 7 2006.08 33 14.21 2912 3 3
4 13 1528.36 27 14.31 2350 3 3
5 13 641.88 27 14.64 1236 3 3

Cycle 148

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 14.85 528 3 3
2 12 1180.44 4 14.73 2014 3 3
3 7 2005.88 33 14.21 2917 3 3
4 13 1527.84 27 14.31 2324 3 3
5 13 641.84 27 14.65 1220 3 3

Cycle 147

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 14.85 546 3 3
2 12 1164.08 4 14.73 1941 3 3
3 7 2003.44 34 14.20 2903 3 3
4 13 1496.84 27 14.32 2295 3 3
5 13 608.80 27 14.67 1166 3 3

Cycle 146

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 28 14.84 561 3 3
2 12 1179.28 4 14.72 1975 3 3
3 7 2001.92 33 14.21 2894 3 3
4 13 1514.20 27 14.31 2327 3 3
5 13 649.00 27 14.65 1236 3 3

Cycle 145

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 14.84 569 3 3
2 12 1162.40 4 14.75 1988 3 3
3 7 2002.52 33 14.20 2928 3 3
4 13 1501.60 27 14.33 2335 3 3
5 13 622.64 27 14.66 1198 3 3

Cycle 144

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 28 14.86 512 3 3
2 12 1151.72 4 14.76 1921 3 3
3 7 2002.92 33 14.21 2922 3 3
4 13 1519.48 27 14.33 2335 3 3
5 13 633.32 27 14.64 1222 3 3

Cycle 143

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 28 14.88 513 3 3
2 12 1177.20 4 14.77 1959 3 3
3 7 2003.64 33 14.21 2890 3 3
4 13 1511.36 27 14.33 2318 3 3
5 13 760.24 27 14.60 1365 3 3

Cycle 142

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 28 14.86 528 3 3
2 12 1162.88 4 14.76 1969 3 3
3 7 2003.20 33 14.21 2908 3 3
4 13 1504.56 27 14.33 2315 3 3
5 13 622.08 27 14.67 1169 3 3

Cycle 141

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 28 14.84 569 3 3
2 3 1026.32 1 15.02 1801 3 3
3 12 1165.12 4 14.76 1993 3 3
4 7 2008.12 33 14.21 2909 3 3
5 13 1522.36 27 14.33 2331 3 3
6 13 617.00 27 14.67 1181 3 3

Cycle 140

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 14.87 522 3 3
2 12 1163.84 4 14.75 1927 3 3
3 7 2004.04 33 14.20 2906 3 3
4 13 1490.64 27 14.34 2279 3 3
5 13 734.48 27 14.59 1369 3 3
6 13 64.84 6 14.99 526 3 3

Cycle 139

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 28 14.86 555 3 3
2 12 1171.36 4 14.77 1971 3 3
3 7 2005.76 33 14.21 2909 3 3
4 13 1512.28 27 14.34 2313 3 3
5 13 610.56 27 14.67 1167 3 3

Cycle 138

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 26 14.87 526 3 3
2 10 1014.16 3 14.66 1773 3 3
3 3 963.52 -1 15.39 0 3 3
4 12 1164.40 4 14.76 1941 3 3
5 7 2001.28 33 14.22 2906 3 3
6 13 1486.16 27 14.34 2291 3 3
7 13 614.00 27 14.67 1175 3 3

Cycle 137

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 33 14.90 544 3 3
2 3 791.36 -4 15.41 0 3 3
3 3 927.32 -1 15.44 0 3 3
4 12 1127.68 4 14.79 1927 3 3
5 7 2001.08 33 14.22 2932 3 3
6 13 1500.76 27 14.35 2311 3 3
7 13 609.12 27 14.67 1199 3 3
8 13 56.64 5 15.03 512 3 3

Cycle 136

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 27 14.91 568 3 3
2 12 1159.28 4 14.71 1984 3 3
3 7 1525.24 33 14.45 2351 3 3
4 13 1386.04 27 14.47 2185 3 3
5 13 639.92 27 14.71 1238 3 3

Cycle 135

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 27 14.90 553 3 3
2 12 1167.24 4 14.69 1976 3 3
3 7 1524.28 33 14.46 2353 3 3
4 13 1379.84 27 14.48 2137 3 3
5 13 466.88 27 14.79 1006 3 3

Cycle 134

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 27 14.90 554 3 3
2 12 1168.12 4 14.71 1980 3 3
3 7 1524.76 33 14.46 2350 3 3
4 13 1383.24 27 14.46 2189 3 3
5 13 494.36 27 14.78 1041 3 3

Cycle 133

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 27 14.91 542 3 3
2 12 1168.32 4 14.71 1925 3 3
3 7 1525.72 33 14.46 2328 3 3
4 13 1379.60 27 14.46 2153 3 3
5 13 472.68 27 14.79 1015 3 3

Cycle 130 GMT 10/ 3/2021 0:34: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 14.77 551 3 3
2 10 1016.60 3 14.63 1777 3 3
3 3 935.00 -1 15.38 0 3 3
4 3 972.00 -1 15.41 0 3 3
5 12 1197.60 4 14.75 1981 3 3
6 7 2002.60 33 14.22 2927 3 3
7 13 1497.48 27 14.33 2306 3 3
8 13 596.28 27 14.68 1174 3 3
9 13 37.36 27 14.94 460 3 3
10 8 0.24 180 14.90 385 3 4

Cycle 128 GMT 18/ 2/2021 4: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 14.84 571 3 3
2 3 946.68 -1 15.40 0 3 3
3 12 1151.28 4 14.74 1932 3 3
4 7 2003.12 33 14.21 2894 3 3
5 13 1507.84 27 14.33 2336 3 3
6 13 606.80 27 14.66 1204 3 3
7 13 19.60 27 14.94 458 3 3
8 8 0.24 180 14.87 414 3 4

Cycle 127

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 28 14.84 579 3 3
2 10 1013.28 3 14.68 1832 3 3
3 3 944.16 -1 15.39 0 3 3
4 12 1153.72 4 14.73 2028 3 3
5 7 2002.84 33 14.21 2932 3 3
6 13 1498.04 27 14.34 2314 3 3
7 13 748.56 27 14.60 1371 3 3

Cycle 126

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 28 14.85 560 3 3
2 12 1155.52 4 14.75 1976 3 3
3 7 2002.76 33 14.21 2929 3 3
4 13 1505.36 27 14.34 2318 3 3
5 13 616.76 27 14.66 1204 3 3
6 13 41.12 5 15.04 465 3 3

Cycle 94 GMT 17/ 3/2020 21:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 33 14.82 603 3 3
2 12 1148.44 4 14.77 1976 3 3
3 7 1519.32 34 14.49 2350 3 3
4 13 1369.80 27 14.50 2198 3 3
5 13 459.56 27 14.83 1022 3 3
6 8 0.48 180 14.98 410 3 3
7 14 0.48 25 14.97 420 3 3

Cycle 93 GMT 16/ 3/2020 22:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 33 14.82 606 3 3
2 12 1175.28 4 14.72 2070 3 3
3 7 1525.96 33 14.49 2357 3 3
4 13 1381.88 27 14.48 2203 3 3
5 13 480.20 27 14.82 1045 3 3
6 8 0.16 180 14.98 418 3 3

Cycle 92 GMT 16/ 3/2020 0:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 33 14.78 599 3 3
2 12 1157.44 4 14.75 2000 3 3
3 7 1505.68 34 14.48 2340 3 3
4 13 1361.44 27 14.49 2165 3 3
5 13 449.72 27 14.83 1000 3 3
6 8 0.08 180 14.97 420 3 3

Cycle 91 GMT 15/ 3/2020 1:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 31 14.83 579 3 3
2 10 1030.80 3 14.67 1805 3 3
3 3 964.64 -1 15.43 0 3 3
4 12 1177.56 4 14.76 2052 3 3
5 7 2002.40 33 14.23 2929 3 3
6 13 1497.56 27 14.39 2300 3 3
7 13 589.60 27 14.71 1187 3 3
8 13 44.24 5 15.08 494 3 3
9 8 0.08 180 14.92 421 3 5
10 14 0.08 25 14.91 425 3 6

Cycle 90 GMT 5/ 3/2020 3: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 33 14.81 622 3 3
2 12 1165.92 4 14.74 2012 3 3
3 7 1523.80 33 14.49 2361 3 3
4 13 1376.96 27 14.50 2187 3 3
5 13 480.24 27 14.83 1043 3 3
6 8 0.16 180 14.98 420 3 9

Cycle 89 GMT 4/ 3/2020 4:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 14.82 601 3 3
2 12 1173.36 4 14.77 1974 3 3
3 7 1524.68 33 14.48 2367 3 3
4 13 1379.80 27 14.50 2193 3 3
5 13 464.84 27 14.83 1023 3 3
6 8 0.32 180 14.97 436 3 4

Cycle 88 GMT 3/ 3/2020 5:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 33 14.82 583 3 3
2 12 1166.96 4 14.74 2015 3 3
3 7 1524.76 33 14.49 2385 3 3
4 13 1384.28 27 14.49 2206 3 3
5 13 495.20 27 14.82 1066 3 3
6 8 0.20 180 14.97 432 3 4

Cycle 87 GMT 2/ 3/2020 6:41: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 33 14.81 600 3 3
2 12 1171.84 4 14.77 1988 3 3
3 7 1521.00 33 14.50 2357 3 3
4 13 1372.64 27 14.50 2188 3 3
5 13 471.20 27 14.83 1032 3 3
6 8 0.00 180 14.98 419 3 3

Cycle 86 GMT 1/ 3/2020 7:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 33 14.82 591 3 3
2 3 1018.60 1 15.07 1866 3 3
3 12 1167.64 4 14.74 2061 3 3
4 7 1505.96 33 14.49 2353 3 3
5 13 1374.76 27 14.49 2208 3 3
6 13 478.44 27 14.81 1061 3 3
7 8 0.24 180 14.96 438 3 4

Cycle 85 GMT 29/ 2/2020 9: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 33 14.79 600 3 3
2 12 1163.36 4 14.75 2003 3 3
3 7 1525.84 34 14.48 2342 3 3
4 13 1381.40 27 14.47 2223 3 3
5 13 467.80 27 14.81 1049 3 3
6 8 0.12 180 14.96 440 3 6

Cycle 84 GMT 28/ 2/2020 10:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 18 14.81 580 3 3
2 10 1053.16 8 14.48 1825 3 3
3 10 1096.08 4 14.52 1964 3 3
4 3 1091.12 2 14.75 1966 3 3
5 12 1180.84 4 14.79 1969 3 3
6 7 2002.28 33 14.26 2921 3 3
7 13 1503.92 27 14.39 2336 3 3
8 13 626.52 27 14.70 1240 3 3
9 8 0.04 180 14.93 431 3 4
10 14 0.04 25 14.92 432 3 5

Cycle 83 GMT 18/ 2/2020 12: 5: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 20 14.90 586 3 3
2 3 930.20 -1 15.43 0 3 3
3 12 1153.40 4 14.75 1967 3 3
4 7 2004.40 33 14.26 2938 3 3
5 13 1502.32 27 14.40 2336 3 3
6 13 766.36 27 14.63 1419 3 3
7 13 17.24 27 14.99 464 3 3
8 8 0.08 180 14.91 437 3 4

Cycle 82

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 24 14.90 595 3 3
2 3 811.52 -4 15.43 0 3 3
3 12 1181.12 4 14.74 2054 3 3
4 7 2001.32 33 14.27 2913 3 3
5 13 1497.64 27 14.39 2325 3 3
6 13 593.92 27 14.72 1185 3 3

Cycle 81

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 24 14.89 608 3 3
2 12 1164.52 4 14.77 1973 3 3
3 7 2004.16 33 14.26 2946 3 3
4 13 1498.84 27 14.40 2340 3 3
5 13 594.32 27 14.72 1193 3 3

Cycle 80

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 24 14.90 591 3 3
2 12 1174.60 4 14.80 2003 3 3
3 7 2001.04 33 14.26 2918 3 3
4 13 1497.40 27 14.41 2328 3 3
5 13 598.24 27 14.72 1185 3 3

Cycle 79

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 23 14.89 610 3 3
2 10 1006.56 3 14.72 1852 3 3
3 3 944.92 -1 15.43 0 3 3
4 12 1161.44 4 14.79 1979 3 3
5 7 2004.52 33 14.26 2909 3 3
6 13 1489.96 27 14.41 2293 3 3
7 13 586.24 27 14.73 1175 3 3

Cycle 78

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 23 14.90 608 3 3
2 12 1174.04 4 14.80 1993 3 3
3 7 2004.20 33 14.26 2947 3 3
4 13 1507.76 27 14.40 2350 3 3
5 13 602.44 27 14.72 1203 3 3

Cycle 77

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 24 14.89 612 3 3
2 3 943.36 -1 15.44 0 3 3
3 12 1153.72 4 14.81 1970 3 3
4 7 2002.88 33 14.27 2943 3 3
5 13 1503.76 27 14.41 2341 3 3
6 13 608.84 27 14.72 1202 3 3

Cycle 76

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 23 14.90 602 3 3
2 10 1007.56 3 14.73 1810 3 3
3 3 943.16 -1 15.43 0 3 3
4 12 1164.20 4 14.79 2013 3 3
5 7 2001.08 33 14.27 2943 3 3
6 13 1505.24 27 14.40 2363 3 3
7 13 606.44 27 14.72 1208 3 3

Cycle 75

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 24 14.90 593 3 3
2 12 1159.24 4 14.79 1953 3 3
3 7 2002.96 33 14.27 2927 3 3
4 13 1491.32 27 14.40 2325 3 3
5 13 575.44 27 14.74 1175 3 3

Cycle 74

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 23 14.90 594 3 3
2 3 1020.16 1 15.05 1814 3 3
3 12 1168.88 4 14.80 1962 3 3
4 7 2002.84 33 14.28 2927 3 3
5 13 1504.20 27 14.42 2334 3 3
6 13 747.04 27 14.66 1391 3 3

Cycle 73

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 19 14.92 587 3 3
2 10 1047.92 5 14.61 1900 3 3
3 12 1166.12 4 14.82 1949 3 3
4 7 2004.16 33 14.28 2926 3 3
5 13 1509.40 27 14.41 2343 3 3
6 13 620.48 27 14.71 1232 3 3

Cycle 72

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 20 14.91 592 3 3
2 3 971.72 -1 15.44 0 3 3
3 12 1185.32 4 14.79 1979 3 3
4 7 2001.16 33 14.28 2892 3 3
5 13 1494.80 27 14.42 2299 3 3
6 13 602.52 27 14.74 1198 3 3

Cycle 71

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 19 14.92 594 3 3
2 3 1042.56 1 14.99 1875 3 3
3 12 1168.68 4 14.80 1992 3 3
4 7 2003.28 33 14.27 2926 3 3
5 13 1518.20 27 14.40 2353 3 3
6 13 610.04 27 14.72 1211 3 3
7 13 56.36 5 15.09 519 3 3

Cycle 70

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 21 14.92 596 3 3
2 3 915.00 -2 15.44 0 3 3
3 12 1168.52 4 14.82 1987 3 3
4 7 2002.12 33 14.28 2922 3 3
5 13 1491.72 27 14.42 2309 3 3
6 13 592.56 27 14.74 1182 3 3

Cycle 69

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 19 14.92 593 3 3
2 10 1026.04 3 14.71 1817 3 3
3 3 962.32 -1 15.44 0 3 3
4 12 1173.60 4 14.80 1951 3 3
5 7 2003.76 33 14.28 2937 3 3
6 13 1498.20 27 14.42 2324 3 3
7 13 600.32 27 14.73 1205 3 3

Cycle 68

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 24 14.92 592 3 3
2 3 777.92 -4 15.44 0 3 3
3 3 963.64 -1 15.47 0 3 3
4 12 1192.28 4 14.76 2090 3 3
5 7 2003.40 33 14.29 2924 3 3
6 13 1517.36 27 14.42 2362 3 3
7 13 615.72 27 14.73 1223 3 3

Cycle 67

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 24 14.91 602 3 3
2 12 1168.72 4 14.78 1966 3 3
3 7 1870.08 33 14.32 2768 3 3
4 13 1552.60 27 14.40 2397 3 3
5 13 625.12 27 14.72 1233 3 3

Cycle 66

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 24 14.90 617 3 3
2 12 1173.16 4 14.78 2056 3 3
3 7 2003.00 33 14.26 2909 3 3
4 13 1512.68 27 14.40 2367 3 3
5 13 573.48 27 14.75 1165 3 3

Cycle 65

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.90 588 3 3
2 3 846.84 -3 15.44 0 3 3
3 12 1149.44 4 14.79 2022 3 3
4 7 2002.84 33 14.30 2925 3 3
5 13 1497.04 27 14.43 2321 3 3
6 13 588.72 27 14.75 1184 3 3
7 13 51.20 5 15.10 524 3 3

Cycle 64

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 24 14.95 589 3 3
2 10 1007.36 5 14.68 1788 3 3
3 3 971.88 -1 15.47 0 3 3
4 12 1223.24 4 14.76 2090 3 3
5 7 2009.92 33 14.28 2918 3 3
6 13 1376.68 27 14.46 2167 3 3
7 13 546.88 27 14.76 1133 3 3

Cycle 63

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 22 14.94 592 3 3
2 10 1017.72 4 14.69 1785 3 3
3 3 968.24 -1 15.45 0 3 3
4 12 1155.48 4 14.83 1953 3 3
5 7 1574.28 33 14.47 2416 3 3
6 13 1253.20 27 14.54 2031 3 3
7 13 524.72 27 14.80 1105 3 3
8 13 53.84 5 15.13 512 3 3

Cycle 62

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 19 14.94 594 3 3
2 10 1029.80 5 14.64 1814 3 3
3 12 1164.80 4 14.80 1961 3 3
4 7 2003.72 33 14.31 2927 3 3
5 13 1505.80 27 14.42 2334 3 3
6 13 758.80 27 14.68 1391 3 3

Cycle 61

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 18 14.94 578 3 3
2 12 1161.72 4 14.82 1960 3 3
3 7 2002.44 33 14.32 2903 3 3
4 13 1504.60 27 14.43 2345 3 3
5 13 589.28 27 14.77 1157 3 3

Cycle 60

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 20 14.94 594 3 3
2 3 953.00 -1 15.45 0 3 3
3 12 1158.12 4 14.81 1942 3 3
4 7 2003.04 33 14.30 2937 3 3
5 13 1493.28 27 14.45 2304 3 3
6 13 602.04 27 14.75 1201 3 3

Cycle 59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 20 14.95 573 3 3
2 12 1177.96 4 14.81 2028 3 3
3 7 2001.04 33 14.29 2948 3 3
4 13 1508.80 27 14.42 2362 3 3
5 13 594.04 27 14.75 1198 3 3

Cycle 58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 26 14.93 580 3 3
2 3 722.84 -5 15.45 0 3 3
3 3 947.12 -1 15.48 0 3 3
4 12 1169.20 4 14.82 2001 3 3
5 7 2002.08 33 14.31 2937 3 3
6 13 1494.64 27 14.44 2310 3 3
7 13 578.84 27 14.77 1177 3 3

Cycle 57

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 28 14.94 590 3 3
2 3 949.40 -1 15.45 0 3 3
3 12 1160.48 4 14.81 1995 3 3
4 7 2002.72 33 14.30 2940 3 3
5 13 1480.28 27 14.45 2307 3 3
6 13 567.96 27 14.78 1159 3 3

Cycle 56

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 14.94 583 3 3
2 3 896.40 -2 15.46 0 3 3
3 12 1168.72 4 14.77 2011 3 3
4 7 2001.00 33 14.32 2932 3 3
5 13 1488.24 27 14.46 2302 3 3
6 13 577.72 27 14.78 1158 3 3
7 13 52.24 5 15.12 503 3 3

Cycle 55

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 33 14.94 594 3 3
2 3 857.84 -3 15.46 0 3 3
3 12 1163.00 4 14.81 1987 3 3
4 7 2000.76 33 14.31 2936 3 3
5 13 1499.04 27 14.44 2328 3 3
6 13 598.76 27 14.77 1193 3 3
7 13 50.48 5 15.12 494 3 3

Cycle 54

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 33 14.86 594 3 3
2 12 1171.44 4 14.80 1995 3 3
3 7 2002.88 33 14.32 2935 3 3
4 13 1501.96 27 14.45 2348 3 3
5 13 575.88 27 14.78 1169 3 3

Cycle 53 GMT 26/ 4/2019 19:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 33 14.88 581 3 3
2 10 1006.52 3 14.74 1811 3 3
3 3 933.80 -1 15.44 0 3 3
4 12 1164.88 4 14.81 1978 3 3
5 7 2002.00 33 14.32 2936 3 3
6 13 1504.72 27 14.45 2354 3 3
7 13 590.44 27 14.78 1189 3 3
8 13 51.84 5 15.12 518 3 3
9 8 0.40 180 14.98 436 3 4

Cycle 52 GMT 16/ 4/2019 21: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 14.87 577 3 3
2 12 1158.04 4 14.82 1982 3 3
3 7 2000.20 33 14.33 2924 3 3
4 13 1485.20 27 14.46 2320 3 3
5 13 728.80 27 14.72 1380 3 3
6 8 0.32 180 14.99 436 3 4

Cycle 51 GMT 6/ 4/2019 22:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 33 14.88 596 3 3
2 12 1162.44 4 14.82 1953 3 3
3 7 2003.12 33 14.33 2948 3 3
4 13 1492.84 25 14.47 2306 3 3
5 13 751.28 25 14.71 1405 3 3
6 13 77.72 6 15.09 542 3 3
7 13 45.28 5 15.13 512 3 3
8 8 0.04 180 14.98 442 3 4

Cycle 50 GMT 27/ 3/2019 23:46: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 33 14.89 590 3 3
2 12 1178.80 4 14.85 1975 3 3
3 7 2001.00 34 14.31 2943 3 3
4 13 1484.40 25 14.47 2322 3 3
5 13 757.16 25 14.71 1400 3 3
6 13 51.80 5 15.14 503 3 3
7 8 0.32 180 15.00 429 3 9

Cycle 49 GMT 18/ 3/2019 0:54: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 33 14.88 603 3 3
2 3 969.20 -1 15.46 0 3 3
3 12 1166.52 4 14.75 2037 3 3
4 7 1523.84 33 14.54 2348 3 3
5 13 1378.24 25 14.54 2163 3 3
6 13 501.08 25 14.85 1076 3 3
7 13 18.16 25 15.07 466 3 3
8 8 0.24 180 15.00 432 3 3

Cycle 48 GMT 17/ 3/2019 2: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 34 14.87 590 3 3
2 3 971.76 -1 15.49 0 3 3
3 12 1204.76 4 14.77 2045 3 3
4 7 1514.12 33 14.53 2343 3 3
5 13 1377.32 25 14.54 2185 3 3
6 13 645.16 25 14.79 1246 3 3
7 8 0.04 180 15.02 428 3 5

Cycle 47 GMT 16/ 3/2019 3:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 33 14.87 586 3 3
2 10 1015.24 3 14.78 1822 3 3
3 3 967.12 -1 15.44 0 3 3
4 12 1162.28 3 14.83 2000 3 3
5 7 1523.68 35 14.51 2354 3 3
6 13 1375.08 25 14.53 2181 3 3
7 13 629.84 25 14.78 1242 3 3
8 13 44.16 5 15.15 480 3 3
9 8 0.20 180 15.02 417 3 4

Cycle 46 GMT 15/ 3/2019 5: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 31 14.88 582 3 3
2 10 1013.76 3 14.73 1828 3 3
3 3 963.76 -1 15.45 0 3 3
4 12 1176.64 3 14.86 2035 3 3
5 7 2003.08 35 14.33 2918 3 3
6 13 1336.16 25 14.52 2130 3 3
7 13 664.52 25 14.76 1290 3 3
8 13 58.40 5 15.14 517 3 3
9 13 42.80 5 15.14 499 3 3
10 8 -0.08 180 15.00 429 3 5

Cycle 45 GMT 5/ 3/2019 6:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 33 14.87 582 3 3
2 12 1167.48 3 14.84 2037 3 3
3 7 1524.96 35 14.54 2354 3 3
4 13 1374.48 25 14.56 2146 3 3
5 13 494.16 25 14.85 1071 3 3
6 8 0.16 180 15.02 427 3 6

Cycle 44 GMT 4/ 3/2019 7:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 33 14.87 593 3 3
2 12 1150.84 3 14.87 1992 3 3
3 7 1525.24 35 14.53 2356 3 3
4 13 1376.20 25 14.54 2169 3 3
5 13 477.96 25 14.87 1019 3 3
6 13 18.12 25 15.08 452 3 3
7 8 0.20 180 15.01 420 3 4

Cycle 43 GMT 3/ 3/2019 9: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 14.88 591 3 3
2 10 1028.04 4 14.66 1877 3 3
3 12 1154.36 3 14.84 1972 3 3
4 7 1523.88 35 14.52 2357 3 3
5 13 1374.40 25 14.53 2189 3 3
6 13 625.48 25 14.79 1228 3 3
7 13 43.32 5 15.15 479 3 3
8 8 0.00 180 15.01 435 3 4

Cycle 42 GMT 2/ 3/2019 10:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 21 14.89 602 3 3
2 10 1016.96 8 14.59 1848 3 3
3 10 1049.16 3 14.71 1847 3 3
4 12 1161.72 3 14.90 1988 3 3
5 7 2002.96 35 14.34 2958 3 3
6 13 1471.56 24 14.50 2308 3 3
7 13 742.88 24 14.74 1399 3 3
8 13 35.44 24 15.06 490 3 3
9 8 0.12 180 15.00 439 3 5

Cycle 41 GMT 20/ 2/2019 12:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 20 14.99 611 3 3
2 10 1012.28 3 14.82 1817 3 3
3 3 947.08 -1 15.48 0 3 3
4 12 1166.88 3 14.87 1993 3 3
5 7 2003.08 35 14.33 2951 3 3
6 13 1494.24 24 14.50 2322 3 3
7 13 762.52 24 14.73 1424 3 3
8 13 37.80 24 15.06 486 3 3
9 8 0.32 180 14.99 443 3 4

Cycle 40

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 17 15.00 602 3 3
2 10 1022.16 4 14.73 1790 3 3
3 12 1153.48 3 14.93 1953 3 3
4 7 2002.60 35 14.34 2938 3 3
5 13 1481.08 24 14.49 2316 3 3
6 13 746.92 24 14.74 1400 3 3
7 13 51.92 5 15.16 490 3 3

Cycle 39

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 21 15.00 586 3 3
2 3 849.92 -3 15.49 0 3 3
3 12 1150.00 3 14.89 2022 3 3
4 7 2002.04 35 14.34 2936 3 3
5 13 1474.20 24 14.50 2303 3 3
6 13 728.20 24 14.75 1378 3 3
7 13 68.08 6 15.12 533 3 3

Cycle 38

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 21 14.98 613 3 3
2 12 1166.28 3 14.92 1986 3 3
3 7 2002.68 35 14.35 2928 3 3
4 13 1474.88 24 14.51 2297 3 3
5 13 746.12 24 14.75 1382 3 3
6 13 51.20 5 15.15 504 3 3
7 13 23.44 5 15.16 481 3 3

Cycle 37

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 20 14.99 621 3 3
2 10 1001.32 3 14.82 1810 3 3
3 3 938.80 -1 15.49 0 3 3
4 12 1158.00 3 14.90 1938 3 3
5 7 2002.12 35 14.35 2934 3 3
6 13 1483.80 24 14.50 2319 3 3
7 13 610.56 24 14.81 1218 3 3
8 13 56.56 5 15.15 517 3 3

Cycle 36

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 20 14.99 631 3 3
2 3 965.08 -1 15.49 0 3 3
3 12 1169.96 3 14.91 1986 3 3
4 7 2005.96 35 14.36 2948 3 3
5 13 1338.08 24 14.56 2137 3 3
6 13 646.32 24 14.79 1271 3 3
7 13 42.80 5 15.16 487 3 3

Cycle 35

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 19 15.00 613 3 3
2 10 1013.52 3 14.82 1783 3 3
3 3 956.20 -1 15.49 0 3 3
4 12 1170.24 3 14.90 1955 3 3
5 7 2003.40 35 14.35 2940 3 3
6 13 1481.00 24 14.51 2316 3 3
7 13 594.96 24 14.82 1195 3 3
8 13 58.20 5 15.15 519 3 3

Cycle 34

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 16 15.00 593 3 3
2 10 1013.48 5 14.73 1808 3 3
3 3 966.40 -1 15.49 0 3 3
4 3 1020.52 1 15.19 1796 3 3
5 12 1167.72 3 14.92 1984 3 3
6 7 2004.44 35 14.36 2930 3 3
7 13 1487.28 24 14.51 2334 3 3
8 13 604.16 24 14.82 1203 3 3
9 13 55.88 5 15.15 522 3 3

Cycle 33

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 19 15.00 600 3 3
2 3 847.04 -3 15.50 0 3 3
3 12 1158.32 3 14.91 2018 3 3
4 7 2002.52 35 14.36 2889 3 3
5 13 1341.96 24 14.57 2128 3 3
6 13 639.64 24 14.80 1263 3 3
7 13 58.16 5 15.16 512 3 3

Cycle 32

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 19 15.00 621 3 3
2 12 1167.64 3 14.92 2004 3 3
3 7 2010.84 35 14.35 2964 3 3
4 13 1346.20 24 14.56 2161 3 3
5 13 656.72 24 14.79 1294 3 3
6 13 58.48 5 15.15 525 3 3

Cycle 31

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 20 14.99 638 3 3
2 12 1157.44 3 14.93 1990 3 3
3 7 2003.20 35 14.36 2935 3 3
4 13 1480.28 24 14.53 2314 3 3
5 13 744.68 24 14.75 1398 3 3
6 13 72.16 6 15.13 536 3 3

Cycle 30

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 19 15.02 625 3 3
2 3 1027.68 1 15.10 1826 3 3
3 12 1169.92 3 14.93 1990 3 3
4 7 2002.20 35 14.37 2950 3 3
5 13 1477.96 24 14.52 2312 3 3
6 13 735.56 24 14.77 1378 3 3
7 13 51.32 5 15.17 508 3 3

Cycle 29

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 19 15.02 600 3 3
2 12 1143.28 3 14.93 1951 3 3
3 7 2002.68 35 14.37 2941 3 3
4 13 1479.40 24 14.52 2312 3 3
5 13 606.08 24 14.83 1213 3 3
6 13 55.60 5 15.17 516 3 3

Cycle 28

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 19 15.02 602 3 3
2 3 1042.72 1 15.07 1854 3 3
3 12 1179.60 3 14.94 1994 3 3
4 7 2002.60 35 14.38 2956 3 3
5 13 1471.28 24 14.53 2308 3 3
6 13 591.52 24 14.83 1191 3 3
7 13 54.40 5 15.17 510 3 3

Cycle 27

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 18 15.02 611 3 3
2 12 1169.64 3 14.93 2010 3 3
3 7 2002.80 35 14.38 2940 3 3
4 13 1481.16 24 14.54 2313 3 3
5 13 602.28 24 14.83 1206 3 3
6 13 53.88 5 15.18 507 3 3

Cycle 26

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 19 15.01 616 3 3
2 12 1145.32 3 14.91 1973 3 3
3 7 2004.40 35 14.38 2943 3 3
4 13 1490.84 24 14.53 2333 3 3
5 13 754.24 24 14.77 1414 3 3
6 13 51.84 5 15.17 509 3 3

Cycle 25

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 20 15.02 602 3 3
2 3 962.36 -1 15.52 0 3 3
3 12 1164.60 3 14.94 2010 3 3
4 7 2003.32 35 14.38 2947 3 3
5 13 1478.76 24 14.53 2325 3 3
6 13 596.24 24 14.84 1205 3 3
7 13 55.76 5 15.17 523 3 3

Cycle 24

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 21 15.01 632 3 3
2 3 954.76 -1 15.52 0 3 3
3 12 1177.40 3 14.91 2004 3 3
4 7 2001.96 35 14.39 2957 3 3
5 13 1477.72 24 14.54 2327 3 3
6 13 592.24 24 14.85 1203 3 3
7 13 47.12 5 15.18 518 3 3

Cycle 23

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 19 15.01 626 3 3
2 10 1002.12 3 14.84 1825 3 3
3 3 938.72 -1 15.52 0 3 3
4 12 1159.76 3 14.94 2032 3 3
5 7 2001.68 35 14.38 2943 3 3
6 13 1477.32 24 14.55 2318 3 3
7 13 591.48 24 14.85 1203 3 3
8 13 58.80 5 15.17 511 3 3

Cycle 22

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 18 15.02 629 3 3
2 3 1043.20 1 15.07 1863 3 3
3 12 1175.32 3 14.92 1989 3 3
4 7 2002.12 35 14.39 2960 3 3
5 13 1483.48 24 14.54 2332 3 3
6 13 741.16 24 14.78 1408 3 3
7 13 68.72 6 15.15 528 3 3
8 13 45.28 5 15.18 523 3 3

Cycle 21

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 19 15.02 611 3 3
2 12 1157.72 3 14.93 2002 3 3
3 7 2003.84 36 14.40 2946 3 3
4 13 1336.16 24 14.59 2147 3 3
5 13 633.16 24 14.83 1263 3 3
6 13 45.64 5 15.18 516 3 3

Cycle 20

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 18 15.03 628 3 3
2 3 1018.44 1 15.18 1875 3 3
3 12 1169.20 3 14.93 1979 3 3
4 7 2001.16 35 14.40 2938 3 3
5 13 1474.96 24 14.56 2318 3 3
6 13 730.64 24 14.79 1387 3 3
7 13 68.16 6 15.16 540 3 3

Cycle 19

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 18 15.04 616 3 3
2 3 1033.84 1 15.14 1833 3 3
3 12 1178.64 3 14.94 2024 3 3
4 7 2002.56 35 14.42 2946 3 3
5 13 1483.96 24 14.55 2315 3 3
6 13 595.04 24 14.86 1221 3 3
7 13 57.12 5 15.18 527 3 3

Cycle 18

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 19 15.05 593 3 3
2 3 944.00 -1 15.54 0 3 3
3 12 1162.16 3 14.95 1997 3 3
4 7 2002.36 35 14.41 2960 3 3
5 13 1480.00 24 14.56 2334 3 3
6 13 731.72 24 14.80 1371 3 3
7 13 67.68 6 15.16 533 3 3

Cycle 17

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 19 15.04 616 3 3
2 12 1149.28 3 14.96 1982 3 3
3 7 2003.24 35 14.41 2950 3 3
4 13 1479.68 24 14.58 2303 3 3
5 13 730.52 24 14.81 1380 3 3

Cycle 16

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 19 15.05 621 3 3
2 3 1028.00 1 15.16 1882 3 3
3 12 1169.04 3 14.98 1995 3 3
4 7 2003.16 35 14.41 2948 3 3
5 13 1484.32 24 14.58 2337 3 3
6 13 745.00 24 14.80 1404 3 3
7 13 73.76 6 15.17 544 3 3

Cycle 15

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 20 15.05 636 3 3
2 3 959.76 -1 15.55 0 3 3
3 12 1179.24 3 14.97 2026 3 3
4 7 2001.80 35 14.44 2957 3 3
5 13 1332.52 24 14.63 2144 3 3
6 13 624.20 24 14.86 1254 3 3
7 13 57.80 5 15.20 534 3 3

Cycle 14

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 32 15.05 603 3 3
2 3 517.28 -9 15.56 0 3 3
3 3 893.76 -2 15.58 0 3 3
4 12 1177.04 3 14.96 2017 3 3
5 7 2003.32 35 14.44 2949 3 3
6 13 1486.32 24 14.58 2340 3 3
7 13 599.44 24 14.88 1191 3 3
8 13 58.44 5 15.20 530 3 3

Cycle 13

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 32 14.95 619 3 3
2 12 1182.24 3 14.98 2041 3 3
3 7 2002.12 35 14.45 2935 3 3
4 13 1339.48 24 14.64 2124 3 3
5 13 636.12 24 14.87 1251 3 3

Cycle 12 GMT 9/ 5/2018 0:43: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 32 14.97 613 3 3
2 12 1174.36 3 14.95 2010 3 3
3 7 2001.68 35 14.45 2969 3 3
4 13 1478.68 24 14.61 2327 3 3
5 13 575.28 24 14.90 1183 3 3
6 8 0.36 180 15.08 448 3 3
7 14 0.36 25 15.07 444 3 3

Cycle 11 GMT 29/ 4/2018 2:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 32 14.99 596 3 3
2 12 1169.44 3 14.97 2044 3 3
3 7 2001.64 35 14.47 2926 3 3
4 13 1481.84 24 14.61 2300 3 3
5 13 582.60 24 14.90 1197 3 3
6 13 56.36 5 15.22 532 3 3
7 8 0.20 180 15.07 454 3 4

Cycle 10 GMT 19/ 4/2018 4:14: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 31 14.99 616 3 3
2 12 1175.08 3 14.99 2005 3 3
3 7 2003.08 35 14.47 2924 3 3
4 13 1484.48 24 14.61 2339 3 3
5 13 581.00 24 14.91 1188 3 3
6 13 52.28 5 15.22 532 3 3
7 8 -0.08 180 15.08 457 3 3

Cycle 9 GMT 9/ 4/2018 6: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 31 14.99 606 3 3
2 12 1172.88 3 14.97 2061 3 3
3 7 2002.24 35 14.47 2941 3 3
4 13 1473.20 24 14.62 2298 3 3
5 13 582.80 24 14.92 1165 3 3
6 13 53.24 5 15.23 523 3 3
7 8 0.20 180 15.08 455 3 3

Cycle 8 GMT 30/ 3/2018 7:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 31 14.99 616 3 3
2 12 1182.68 3 14.96 2007 3 3
3 7 2002.04 35 14.46 2947 3 3
4 13 1325.24 19 14.69 2113 3 3
5 13 817.52 19 14.84 1501 3 3
6 13 123.60 7 15.18 603 3 3
7 13 74.00 6 15.19 561 3 3
8 8 0.24 180 15.08 456 3 3

Cycle 7 GMT 20/ 3/2018 8:45: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 30 15.00 611 3 3
2 3 1019.40 1 15.23 1838 3 3
3 12 1175.72 3 14.98 2027 3 3
4 7 2002.96 35 14.48 2930 3 3
5 13 1480.56 19 14.65 2334 3 3
6 13 777.32 19 14.86 1437 3 3
7 13 119.96 7 15.19 597 3 3
8 13 54.72 5 15.23 531 3 3
9 13 43.60 5 15.22 527 3 3
10 8 -0.04 180 15.08 455 3 4

Cycle 6 GMT 10/ 3/2018 9:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 28 15.01 569 3 3
2 10 1043.76 4 14.84 1860 3 3
3 3 971.44 -1 15.54 0 3 3
4 7 2008.64 36 14.48 2934 3 3
5 13 1487.56 18 14.66 2333 3 3
6 13 828.60 18 14.85 1514 3 3
7 13 304.24 18 15.05 830 3 3
8 8 0.32 180 15.09 451 3 4

Cycle 5 GMT 28/ 2/2018 11:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 22 15.03 591 3 3
2 10 1048.04 6 14.74 1865 3 3
3 3 1059.20 2 15.05 1854 3 3
4 7 2006.16 36 14.48 2905 3 3
5 13 1486.80 18 14.66 2321 3 3
6 13 809.76 18 14.86 1466 3 3
7 13 291.64 18 15.06 797 3 3
8 13 23.92 18 15.16 482 3 3
9 8 -0.20 180 15.09 439 3 3

Cycle 4 GMT 18/ 2/2018 14:12: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 15.01 592 3 3
2 7 1505.96 36 14.66 2336 3 3
3 13 1356.68 18 14.73 2168 3 3
4 13 665.80 18 14.92 1314 3 3
5 13 147.80 18 15.13 628 3 3
6 8 0.36 180 15.10 447 3 5

Cycle 3 GMT 17/ 2/2018 15:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 29 15.00 597 3 3
2 3 1022.56 1 15.19 1829 3 3
3 7 1526.24 36 14.66 2355 3 3
4 13 1232.52 18 14.76 2016 3 3
5 13 721.20 18 14.90 1374 3 3
6 13 94.12 18 15.15 575 3 3
7 8 0.24 180 15.10 451 3 4

Cycle 2 GMT 16/ 2/2018 16:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 24 15.06 588 3 3
2 10 1045.32 5 14.82 1831 3 3
3 7 1506.00 74 14.56 2307 3 3
4 13 123.08 22 15.14 602 3 3
5 8 -0.20 240 15.09 443 3 4

Cycle 1 GMT 15/ 2/2018 18:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 23 15.31 592 3 3
2 10 1024.16 3 14.99 1849 3 3
3 7 976.40 74 14.78 1664 3 3
4 8 -0.04 240 15.14 448 3 5

Cycle 0 GMT 15/ 2/2018 8: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.32 23 15.54 592 3 3
2 7 180.56 74 15.48 585 3 3
3 8 0.32 240 15.43 363 3 24