SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 8914 WMO= 7900797


Cycle 169 GMT 16/ 2/2022 7: 2:11

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 55 15.06 492 2 2
2 10 1789.72 5 14.90 2698 2 2
3 7 2112.24 38 14.73 2955 2 3
4 13 1522.96 20 14.80 2259 2 2
5 13 809.52 20 14.93 1374 2 2
6 13 372.04 14 15.04 819 2 3
7 13 16.00 20 15.14 318 2 2
8 8 -0.40 165 15.08 298 2 2
9 14 -0.40 35 15.06 301 2 2

Cycle 168 GMT 29/ 1/2022 5:41: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 55 15.03 502 2 3
2 7 2128.84 38 14.77 2975 2 3
3 13 1540.20 20 14.87 2282 2 2
4 13 922.20 20 14.98 1504 2 3
5 13 344.28 13 15.12 780 2 3
6 13 106.72 7 15.17 480 2 3
7 8 -0.08 165 15.15 303 2 2

Cycle 167 GMT 28/ 1/2022 12:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 55 15.03 494 2 2
2 10 1788.04 5 14.90 2699 2 2
3 7 2116.12 38 14.72 2963 2 2
4 13 1682.56 20 14.79 2454 2 3
5 13 1128.48 20 14.88 1769 2 3
6 13 840.00 20 14.94 1403 2 3
7 13 266.40 11 15.09 678 2 3
8 13 50.76 5 15.15 380 2 2
9 8 0.04 165 15.11 305 2 2

Cycle 166 GMT 27/ 1/2022 23:18: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 55 15.01 515 2 2
2 7 2121.12 38 14.72 2973 2 3
3 13 1519.60 20 14.84 2256 2 2
4 13 801.00 20 14.98 1367 2 3
5 13 371.72 14 15.09 823 2 3
6 13 60.76 5 15.18 406 2 2
7 8 0.12 165 15.12 312 2 2

Cycle 165 GMT 27/ 1/2022 10:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 55 15.05 527 2 2
2 7 2125.16 38 14.72 2973 2 2
3 13 1708.08 20 14.79 2481 2 2
4 13 1293.84 20 14.85 1980 2 3
5 13 864.36 20 14.94 1433 2 2
6 13 424.08 20 15.04 895 2 3
7 8 0.12 165 15.10 332 2 2

Cycle 164 GMT 26/ 1/2022 21: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 55 15.06 507 2 3
2 7 2116.92 38 14.77 2965 2 3
3 13 1530.48 20 14.87 2267 2 2
4 13 930.36 20 14.97 1535 2 3
5 13 342.88 13 15.11 801 2 3
6 13 62.28 6 15.18 434 2 3
7 8 0.16 165 15.14 338 2 2

Cycle 163 GMT 26/ 1/2022 3:53: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 55 15.06 499 2 2
2 7 2119.88 38 14.77 2967 2 2
3 13 1404.00 20 14.88 2110 2 2
4 13 977.52 20 14.95 1580 2 3
5 13 562.76 20 15.04 1079 2 3
6 13 114.80 7 15.16 515 2 2
7 8 0.20 165 15.14 314 2 2

Cycle 162 GMT 25/ 1/2022 10: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 55 15.06 500 2 2
2 7 2117.24 38 14.77 2964 2 3
3 13 1393.68 20 14.89 2104 2 2
4 13 975.44 20 14.95 1595 2 3
5 13 536.88 20 15.06 1038 2 3
6 13 65.40 6 15.19 424 2 2
7 13 19.68 1 15.20 348 2 2
8 8 -0.04 165 15.14 314 2 2

Cycle 161 GMT 24/ 1/2022 16:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 55 15.06 491 2 2
2 7 2111.68 38 14.77 2958 2 3
3 13 1390.04 20 14.90 2090 2 2
4 13 977.28 20 14.96 1585 2 2
5 13 527.88 20 15.06 1021 2 3
6 13 60.52 5 15.20 401 2 3
7 8 0.08 165 15.16 304 2 2

Cycle 160 GMT 23/ 1/2022 23: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 55 15.03 504 2 3
2 7 2118.64 38 14.77 2968 2 3
3 13 1399.48 20 14.89 2108 2 3
4 13 977.40 20 14.95 1585 2 3
5 13 406.60 20 15.08 870 2 3
6 8 0.28 165 15.15 307 2 2

Cycle 159 GMT 23/ 1/2022 5:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 55 15.07 480 2 2
2 7 2120.12 38 14.74 2968 2 3
3 13 1399.36 20 14.87 2097 2 2
4 13 992.28 20 14.93 1613 2 3
5 13 573.32 20 15.03 1077 2 3
6 13 129.48 7 15.15 520 2 3
7 8 0.20 165 15.13 311 2 2

Cycle 158 GMT 22/ 1/2022 15:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 55 15.05 503 2 2
2 7 2122.68 38 14.78 2974 2 2
3 13 1520.92 20 14.88 2257 2 3
4 13 802.52 20 15.01 1366 2 3
5 13 358.88 14 15.11 801 2 3
6 13 59.16 5 15.19 403 2 2
7 8 1.00 165 15.16 305 2 2
8 14 1.00 35 15.13 307 2 3

Cycle 157 GMT 21/ 1/2022 22: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 55 15.04 496 2 2
2 7 2125.32 38 14.72 2970 2 3
3 13 1534.68 20 14.83 2268 2 2
4 13 810.08 20 14.98 1369 2 3
5 13 374.24 14 15.10 823 2 3
6 8 -0.20 165 15.14 309 2 2

Cycle 156 GMT 21/ 1/2022 9: 2: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 55 15.05 497 2 2
2 7 2120.04 39 14.73 2955 2 3
3 13 1704.36 20 14.81 2476 2 3
4 13 1271.48 20 14.86 1953 2 3
5 13 652.40 20 15.00 1183 2 3
6 13 100.92 7 15.16 473 2 3
7 8 0.20 165 15.14 307 2 2

Cycle 155 GMT 20/ 1/2022 19:57: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 55 15.03 493 2 2
2 7 2128.24 39 14.77 2976 2 3
3 13 1533.04 20 14.87 2266 2 3
4 13 1100.92 20 14.94 1734 2 3
5 13 685.68 20 15.02 1228 2 3
6 13 254.76 11 15.12 672 2 3
7 13 16.36 20 15.18 327 2 2
8 8 -0.12 165 15.14 308 2 2

Cycle 154 GMT 20/ 1/2022 2: 9: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 55 15.05 496 2 2
2 10 1785.40 5 14.93 2674 2 2
3 7 2125.00 38 14.72 2969 2 2
4 13 1528.68 20 14.84 2267 2 3
5 13 1114.16 20 14.90 1741 2 3
6 13 680.24 20 14.99 1196 2 3
7 13 246.32 11 15.11 651 2 3
8 8 0.08 165 15.13 306 2 2

Cycle 153 GMT 19/ 1/2022 12:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 55 15.02 486 2 2
2 7 2110.68 38 14.75 2948 2 3
3 13 1400.56 20 14.88 2102 2 2
4 13 966.28 20 14.96 1566 2 3
5 13 533.52 20 15.04 1025 2 3
6 13 59.64 5 15.18 406 2 3
7 8 0.04 165 15.14 307 2 2

Cycle 152 GMT 18/ 1/2022 21:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 55 15.06 507 2 3
2 7 2126.80 38 14.74 2966 2 2
3 13 1721.32 20 14.79 2491 2 2
4 13 1453.72 20 14.81 2167 2 2
5 13 1027.60 20 14.89 1653 2 2
6 13 583.92 20 15.01 1084 2 2
7 13 73.08 6 15.15 431 2 4
8 13 53.44 5 15.15 394 2 3
9 8 -0.08 165 15.12 305 2 2
10 14 -0.08 35 15.09 307 2 2

Cycle 151 GMT 18/ 1/2022 8:31: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 55 15.05 495 2 2
2 7 2126.52 38 14.78 2970 2 3
3 13 1409.08 20 14.91 2108 2 2
4 13 846.04 20 14.99 1414 2 3
5 13 399.96 15 15.09 857 2 3
6 13 60.84 5 15.19 427 2 2
7 8 0.00 165 15.15 321 2 3

Cycle 150 GMT 17/ 1/2022 15:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 55 15.03 501 2 3
2 7 2124.16 38 14.78 2972 2 2
3 13 1529.60 20 14.86 2266 2 3
4 13 968.56 20 14.96 1572 2 3
5 13 556.40 20 15.05 1071 2 3
6 13 114.96 7 15.18 495 2 3
7 8 0.28 165 15.15 310 2 2
8 14 0.28 35 15.12 313 2 2

Cycle 149 GMT 16/ 1/2022 21:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 55 15.04 482 2 2
2 7 2110.04 39 14.72 2951 2 3
3 13 1406.60 20 14.85 2117 2 2
4 13 983.40 20 14.92 1614 2 3
5 13 554.36 20 15.02 1080 2 3
6 13 109.76 7 15.15 488 2 2
7 8 0.00 165 15.13 311 2 2
8 14 0.00 35 15.11 313 2 3

Cycle 148 GMT 16/ 1/2022 8: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 55 15.04 485 2 2
2 7 2112.96 39 14.73 2951 2 3
3 13 1707.20 20 14.80 2475 2 2
4 13 1461.80 20 14.82 2178 2 2
5 13 1026.76 20 14.89 1643 2 2
6 13 574.16 20 14.99 1086 2 3
7 13 65.64 6 15.15 413 2 2
8 8 -0.04 165 15.12 306 2 2
9 14 -0.04 35 15.10 308 2 2

Cycle 147 GMT 15/ 1/2022 18:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 55 15.06 487 2 3
2 10 1782.08 5 14.91 2683 2 2
3 7 2123.00 38 14.71 2965 2 3
4 13 1522.40 20 14.82 2254 2 3
5 13 805.40 20 14.97 1365 2 3
6 13 369.60 14 15.09 817 2 3
7 13 60.64 5 15.16 408 2 2
8 8 0.04 165 15.14 301 2 2

Cycle 146 GMT 15/ 1/2022 5:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 55 15.07 490 2 3
2 7 2122.28 39 14.74 2972 2 2
3 13 1519.80 20 14.84 2255 2 2
4 13 1093.08 20 14.90 1723 2 3
5 13 540.20 20 15.03 1030 2 3
6 13 102.72 7 15.16 475 2 2
7 8 0.12 165 15.13 301 2 2

Cycle 145 GMT 14/ 1/2022 16:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 55 15.06 492 2 2
2 10 1795.68 5 14.92 2718 2 2
3 7 2107.36 38 14.80 2954 2 2
4 13 1518.96 20 14.87 2253 2 2
5 13 1080.40 20 14.93 1705 2 2
6 13 509.76 20 15.07 986 2 3
7 13 59.12 5 15.21 402 2 2
8 8 0.00 165 15.17 294 2 2

Cycle 144 GMT 5/ 1/2022 1: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 55 15.09 495 2 2
2 7 2138.48 38 14.78 2991 2 3
3 13 1408.92 20 14.91 2121 2 2
4 13 996.64 20 14.96 1600 2 3
5 13 584.12 20 15.05 1097 2 3
6 13 143.20 8 15.17 526 2 3
7 8 0.04 165 15.15 303 2 2

Cycle 143 GMT 4/ 1/2022 7: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 55 15.02 503 2 3
2 10 1783.48 5 14.92 2673 2 2
3 7 2109.60 39 14.82 2959 2 3
4 13 1513.32 20 14.88 2236 2 2
5 13 1081.48 20 14.94 1697 2 2
6 13 663.76 20 15.04 1178 2 3
7 13 231.40 10 15.16 639 2 3
8 13 62.08 6 15.20 405 2 3
9 8 0.04 165 15.17 298 2 2

Cycle 142 GMT 25/12/2021 15:14: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 55 15.04 501 2 2
2 10 1792.52 5 14.92 2658 2 2
3 7 2122.68 39 14.72 2978 2 2
4 13 1510.64 20 14.84 2230 2 2
5 13 1095.76 20 14.90 1725 2 3
6 13 539.44 20 15.03 1029 2 3
7 13 110.92 7 15.15 494 2 3
8 8 0.24 165 15.13 314 2 3
9 14 0.24 35 15.09 318 2 2

Cycle 141 GMT 25/12/2021 2: 1: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 55 15.07 498 2 3
2 7 2107.96 38 14.73 2960 2 2
3 13 1508.96 20 14.85 2238 2 3
4 13 1073.68 20 14.91 1702 2 2
5 13 632.24 20 15.01 1169 2 2
6 13 89.60 6 15.16 466 2 3
7 8 0.08 165 15.13 316 2 2

Cycle 140 GMT 24/12/2021 13: 1: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 55 15.03 500 2 3
2 7 2118.92 38 14.76 2965 2 2
3 13 1698.92 20 14.83 2476 2 2
4 13 1438.16 20 14.85 2161 2 3
5 13 858.44 20 14.97 1443 2 3
6 13 279.40 12 15.12 707 2 3
7 8 0.16 165 15.15 315 2 2

Cycle 139 GMT 23/12/2021 19:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 55 15.06 498 2 2
2 7 2114.68 38 14.74 2969 2 3
3 13 1696.72 20 14.80 2478 2 3
4 13 1285.36 20 14.85 1982 2 3
5 13 725.16 20 14.99 1275 2 3
6 13 289.84 12 15.09 738 2 3
7 13 15.72 20 15.17 330 2 2
8 8 0.20 165 15.12 312 2 2

Cycle 138 GMT 23/12/2021 6:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 55 15.05 503 2 3
2 7 2110.76 38 14.77 2947 2 2
3 13 1496.84 20 14.87 2223 2 3
4 13 972.64 20 14.96 1567 2 3
5 13 558.64 20 15.05 1057 2 3
6 13 64.48 6 15.19 415 2 2
7 8 0.28 165 15.15 308 2 2

Cycle 137 GMT 22/12/2021 13: 6:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 55 15.04 504 2 3
2 7 2118.92 38 14.78 2959 2 3
3 13 1530.76 20 14.88 2260 2 3
4 13 783.60 20 15.02 1336 2 3
5 13 352.68 14 15.11 796 2 3
6 13 61.04 5 15.19 409 2 2
7 8 0.16 165 15.15 315 2 2

Cycle 136 GMT 21/12/2021 19:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 55 15.07 496 2 3
2 7 2114.56 38 14.74 2964 2 3
3 13 1523.44 20 14.85 2255 2 3
4 13 951.64 20 14.95 1563 2 3
5 13 679.92 20 14.99 1213 2 3
6 13 242.20 11 15.10 677 2 2
7 13 62.04 6 15.16 420 2 2
8 8 0.00 165 15.12 317 2 2

Cycle 135 GMT 21/12/2021 6: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 55 15.05 500 2 2
2 7 2114.64 38 14.78 2951 2 3
3 13 1396.56 20 14.90 2111 2 2
4 13 987.00 20 14.96 1593 2 3
5 13 571.60 20 15.05 1076 2 3
6 13 143.24 8 15.16 551 2 3
7 13 44.00 5 15.20 389 2 2
8 8 -0.12 165 15.16 316 2 2

Cycle 134 GMT 20/12/2021 12:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 55 15.07 483 2 2
2 7 2122.60 38 14.75 2964 2 3
3 13 1396.80 20 14.87 2106 2 3
4 13 1000.16 20 14.93 1600 2 3
5 13 602.60 20 15.02 1108 2 3
6 13 177.16 9 15.13 576 2 3
7 8 0.12 165 15.13 307 2 2

Cycle 133 GMT 19/12/2021 22:21: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 55 15.05 488 2 2
2 7 2115.80 38 14.78 2961 2 3
3 13 1517.40 20 14.89 2251 2 2
4 13 980.20 20 14.97 1578 2 2
5 13 610.32 20 15.04 1122 2 3
6 13 208.48 10 15.15 612 2 2
7 13 60.60 5 15.19 414 2 2
8 8 0.24 165 15.17 304 2 2
9 14 0.24 35 15.15 307 2 3

Cycle 132 GMT 19/12/2021 4:17: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 55 15.07 509 2 2
2 7 2118.44 39 14.75 2957 2 3
3 13 1516.96 20 14.85 2251 2 2
4 13 1088.44 20 14.92 1721 2 2
5 13 498.32 20 15.06 983 2 3
6 13 46.96 5 15.19 378 2 2
7 13 16.64 20 15.18 331 2 2
8 8 0.20 165 15.14 308 2 2

Cycle 131 GMT 18/12/2021 14:46: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 55 15.02 504 2 2
2 7 2128.04 38 14.78 2965 2 2
3 13 1401.92 20 14.91 2104 2 2
4 13 819.96 20 15.01 1381 2 3
5 13 377.84 14 15.11 843 2 3
6 13 62.16 6 15.19 426 2 3
7 8 0.04 165 15.15 324 2 2

Cycle 130 GMT 17/12/2021 20:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 55 15.03 502 2 3
2 7 2118.56 38 14.73 2959 2 3
3 13 1505.76 20 14.85 2251 2 2
4 13 1074.00 20 14.91 1728 2 3
5 13 474.36 20 15.05 964 2 3
6 13 44.72 5 15.18 385 2 3
7 8 -0.08 165 15.13 321 2 2

Cycle 129 GMT 17/12/2021 7:35:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 55 15.07 501 2 2
2 7 2108.16 38 14.74 2947 2 3
3 13 1696.00 20 14.80 2485 2 2
4 13 1427.72 20 14.83 2151 2 2
5 13 996.80 20 14.91 1610 2 2
6 13 566.28 20 15.02 1061 2 3
7 13 132.16 7 15.14 530 2 2
8 8 0.08 165 15.12 317 2 2

Cycle 128 GMT 16/12/2021 18:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 55 15.06 498 2 3
2 7 2109.80 38 14.79 2958 2 2
3 13 1690.88 20 14.86 2466 2 3
4 13 1260.88 20 14.91 1938 2 3
5 13 703.16 20 15.04 1248 2 3
6 13 281.96 12 15.14 710 2 3
7 13 52.40 5 15.20 391 2 2
8 8 0.20 165 15.16 310 2 2

Cycle 127 GMT 16/12/2021 0:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 55 15.05 509 2 2
2 7 2119.32 38 14.76 2964 2 3
3 13 1514.68 20 14.87 2253 2 2
4 13 1089.84 20 14.94 1722 2 2
5 13 665.92 20 15.02 1193 2 3
6 13 248.56 11 15.14 665 2 3
7 8 0.20 165 15.15 309 2 2

Cycle 126 GMT 15/12/2021 8:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 55 15.03 506 2 2
2 7 2124.28 38 14.74 2971 2 3
3 13 1534.32 20 14.84 2274 2 2
4 13 1102.68 20 14.92 1736 2 3
5 13 549.20 20 15.03 1053 2 2
6 13 66.28 6 15.18 441 2 2
7 8 0.08 165 15.14 328 2 2

Cycle 125 GMT 14/12/2021 19: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 55 15.05 499 2 3
2 10 1788.28 5 14.90 2701 2 2
3 7 2110.24 39 14.72 2947 2 3
4 13 1497.76 20 14.85 2219 2 3
5 13 946.16 20 14.95 1534 2 2
6 13 549.84 20 15.03 1058 2 3
7 13 131.88 7 15.15 539 2 3
8 8 0.08 165 15.13 319 2 2

Cycle 124 GMT 14/12/2021 5:55: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 55 15.05 508 2 2
2 7 2107.00 39 14.73 2953 2 3
3 13 1395.56 20 14.86 2109 2 3
4 13 978.20 20 14.93 1579 2 3
5 13 557.68 20 15.02 1081 2 3
6 13 117.28 7 15.15 498 2 3
7 8 0.20 165 15.13 310 2 2

Cycle 123 GMT 13/12/2021 16:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 55 15.06 494 2 2
2 7 2117.88 38 14.74 2962 2 3
3 13 1388.16 20 14.87 2100 2 3
4 13 805.92 20 14.99 1370 2 3
5 13 386.00 15 15.10 839 2 3
6 13 19.08 4 15.19 352 2 2
7 8 0.08 165 15.15 327 2 2

Cycle 122 GMT 13/12/2021 3:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 55 15.09 500 2 3
2 7 2111.76 38 14.78 2945 2 3
3 13 1379.52 20 14.91 2073 2 2
4 13 971.48 20 14.97 1575 2 3
5 13 566.16 20 15.05 1086 2 3
6 13 123.72 7 15.18 517 2 3
7 13 8.76 20 15.20 329 2 2
8 8 0.00 165 15.15 316 2 2

Cycle 121 GMT 12/12/2021 11:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 55 15.03 487 2 2
2 5 2089.92 9 14.87 3098 2 2
3 7 2108.20 38 14.81 2949 2 2
4 13 1509.92 20 14.89 2234 2 3
5 13 1056.24 20 14.96 1668 2 2
6 13 454.80 20 15.11 909 2 3
7 8 -0.04 165 15.18 310 2 2
8 14 -0.04 35 15.17 311 2 2

Cycle 120 GMT 2/12/2021 19:29: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 55 15.09 519 2 3
2 7 2115.20 38 14.75 2949 2 2
3 13 1704.60 20 14.82 2469 2 2
4 13 1458.12 20 14.84 2169 2 3
5 13 879.40 20 14.95 1462 2 3
6 13 439.36 20 15.06 926 2 3
7 13 42.92 5 15.18 375 2 3
8 8 0.16 165 15.12 316 2 3
9 14 0.16 35 15.10 318 2 2

Cycle 119 GMT 2/12/2021 6:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 55 15.06 482 2 2
2 5 2081.72 9 14.88 3050 2 2
3 7 2109.44 38 14.82 2951 2 3
4 13 1677.88 20 14.85 2440 2 2
5 13 1101.28 20 14.96 1730 2 2
6 13 520.52 20 15.09 997 2 3
7 13 59.08 5 15.22 402 2 2
8 8 0.04 165 15.18 326 2 2

Cycle 118 GMT 22/11/2021 13:55:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 55 15.03 516 2 2
2 7 2124.72 38 14.75 2967 2 3
3 13 1413.88 20 14.88 2119 2 3
4 13 847.68 20 14.99 1412 2 2
5 13 409.88 20 15.07 861 2 3
6 8 0.16 165 15.15 314 2 2

Cycle 117 GMT 21/11/2021 23:46: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 55 15.06 521 2 2
2 7 2119.08 38 14.76 2957 2 2
3 13 1710.36 20 14.82 2479 2 2
4 13 1449.52 20 14.84 2160 2 2
5 13 1042.84 20 14.91 1652 2 3
6 13 634.52 20 15.01 1155 2 3
7 13 109.84 7 15.15 510 2 3
8 8 0.32 165 15.13 320 2 2
9 14 0.32 35 15.10 322 2 2

Cycle 116 GMT 21/11/2021 9:17: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 55 15.04 517 2 2
2 7 2108.44 38 14.78 2946 2 3
3 13 1501.04 20 14.88 2230 2 2
4 13 1076.96 20 14.95 1701 2 3
5 13 503.04 20 15.08 994 2 3
6 13 64.36 6 15.21 433 2 2
7 13 50.08 5 15.20 411 2 3
8 8 -0.12 165 15.16 328 2 2
9 14 -0.12 35 15.14 328 2 2

Cycle 115 GMT 20/11/2021 15: 1: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 55 15.07 488 2 2
2 7 2116.24 38 14.75 2956 2 2
3 13 1406.68 20 14.88 2109 2 3
4 13 837.92 20 14.99 1396 2 3
5 13 388.16 15 15.10 842 2 3
6 13 61.76 6 15.19 432 2 3
7 8 0.20 165 15.14 330 2 2
8 14 0.20 35 15.11 330 2 2

Cycle 114 GMT 20/11/2021 0:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 55 15.06 509 2 2
2 7 2116.16 38 14.78 2958 2 3
3 13 1523.36 20 14.88 2253 2 2
4 13 1085.44 20 14.95 1706 2 2
5 13 518.20 20 15.07 988 2 3
6 13 59.56 5 15.20 401 2 2
7 8 0.08 165 15.17 311 2 2
8 14 0.08 35 15.14 314 2 2

Cycle 113 GMT 19/11/2021 8: 4: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 55 15.08 499 2 2
2 7 2121.20 38 14.75 2967 2 3
3 13 1382.96 20 14.88 2081 2 3
4 13 983.44 20 14.96 1585 2 3
5 13 583.32 20 15.04 1087 2 3
6 13 91.44 6 15.18 472 2 3
7 13 47.32 5 15.20 404 2 2
8 8 0.08 165 15.15 322 2 2
9 14 0.08 35 15.12 323 2 2

Cycle 112 GMT 18/11/2021 17:44: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 55 15.07 524 2 2
2 7 2111.24 39 14.80 2951 2 2
3 13 1694.36 20 14.86 2459 2 2
4 13 1300.72 20 14.90 1992 2 2
5 13 760.56 20 15.01 1322 2 3
6 13 202.84 9 15.16 615 2 3
7 13 60.56 5 15.19 425 2 3
8 8 0.24 165 15.17 313 2 2

Cycle 111 GMT 17/11/2021 23: 5: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 55 15.07 497 2 2
2 7 2113.76 38 14.79 2957 2 3
3 13 1505.68 20 14.89 2236 2 3
4 13 1071.16 20 14.96 1699 2 2
5 13 483.64 20 15.10 973 2 3
6 13 81.44 6 15.20 467 2 3
7 8 0.04 165 15.16 338 2 2

Cycle 110 GMT 17/11/2021 4:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 55 15.09 510 2 2
2 7 2112.56 38 14.74 2948 2 3
3 13 1528.20 20 14.87 2261 2 3
4 13 921.36 20 14.97 1503 2 2
5 13 320.76 13 15.12 748 2 2
6 13 44.92 5 15.20 379 2 2
7 8 0.00 165 15.15 314 2 2

Cycle 109 GMT 16/11/2021 15:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 55 15.08 507 2 3
2 7 2116.52 38 14.79 2954 2 2
3 13 1528.00 20 14.89 2264 2 2
4 13 799.00 20 15.02 1365 2 2
5 13 376.16 14 15.14 830 2 3
6 8 0.16 165 15.18 318 2 2

Cycle 108 GMT 15/11/2021 21:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 55 15.09 508 2 2
2 5 2099.88 9 14.90 3078 2 2
3 7 2114.16 38 14.77 2949 2 2
4 13 1388.40 20 14.91 2089 2 2
5 13 820.12 20 15.01 1398 2 2
6 13 367.92 14 15.14 827 2 3
7 13 15.76 20 15.21 333 2 2
8 8 -0.12 165 15.17 314 2 2

Cycle 107 GMT 15/11/2021 1:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 55 15.07 497 2 2
2 7 2115.64 38 14.79 2962 2 3
3 13 1496.76 20 14.91 2219 2 3
4 13 1073.36 20 14.96 1693 2 3
5 13 641.76 20 15.05 1166 2 3
6 13 93.96 6 15.21 470 2 3
7 8 0.16 165 15.18 319 2 2

Cycle 106 GMT 14/11/2021 7:15:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 55 15.09 497 2 3
2 7 2118.08 38 14.75 2954 2 2
3 13 1395.00 20 14.88 2103 2 2
4 13 967.68 20 14.96 1570 2 3
5 13 404.88 20 15.10 857 2 3
6 8 0.00 165 15.16 310 2 2

Cycle 105 GMT 13/11/2021 17:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 55 15.09 495 2 3
2 7 2110.76 38 14.80 2948 2 3
3 13 1387.80 20 14.93 2078 2 3
4 13 990.80 20 14.98 1598 2 3
5 13 558.68 20 15.07 1059 2 3
6 13 109.44 7 15.20 491 2 3
7 8 0.52 165 15.18 307 2 2

Cycle 104 GMT 12/11/2021 23:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 55 15.06 506 2 3
2 7 2120.64 39 14.79 2958 2 3
3 13 1540.12 20 14.89 2272 2 3
4 13 972.84 20 14.99 1580 2 2
5 13 562.08 20 15.07 1061 2 3
6 13 121.04 7 15.19 494 2 3
7 13 50.08 5 15.21 391 2 2
8 8 -0.16 165 15.18 308 2 2
9 14 -0.16 35 15.15 309 2 3

Cycle 103 GMT 12/11/2021 4:43:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 55 15.07 495 2 3
2 7 2119.36 38 14.78 2956 2 3
3 13 1414.60 20 14.89 2117 2 2
4 13 1009.32 20 14.96 1620 2 3
5 13 586.92 20 15.06 1094 2 3
6 13 72.80 6 15.19 456 2 3
7 8 -0.08 165 15.16 326 2 2
8 14 -0.08 35 15.13 325 2 2

Cycle 102 GMT 11/11/2021 12:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 55 15.07 500 2 2
2 7 2119.40 38 14.75 2960 2 3
3 13 1527.48 20 14.86 2261 2 2
4 13 1094.16 20 14.93 1730 2 2
5 13 694.72 20 15.01 1226 2 3
6 13 134.04 8 15.15 522 2 3
7 13 51.32 5 15.19 397 2 3
8 8 0.16 165 15.15 309 2 2

Cycle 101 GMT 10/11/2021 22: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 55 15.07 508 2 2
2 7 2113.28 38 14.78 2957 2 3
3 13 1695.24 20 14.84 2484 2 3
4 13 1119.52 20 14.93 1767 2 2
5 13 697.96 20 15.02 1235 2 3
6 13 252.88 11 15.14 674 2 3
7 8 0.00 165 15.16 308 2 2

Cycle 100 GMT 10/11/2021 5:47: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 55 15.08 492 2 2
2 7 2114.04 38 14.76 2947 2 2
3 13 1523.60 20 14.87 2256 2 2
4 13 960.44 20 14.98 1552 2 3
5 13 562.20 20 15.06 1066 2 3
6 13 145.40 8 15.17 545 2 2
7 13 54.68 5 15.19 406 2 2
8 8 0.04 165 15.15 313 2 2

Cycle 99 GMT 9/11/2021 15:33: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 55 15.04 507 2 3
2 7 2107.64 39 14.81 2943 2 2
3 13 1691.88 20 14.86 2467 2 2
4 13 1274.48 20 14.91 1961 2 3
5 13 826.60 20 15.01 1396 2 4
6 13 279.56 12 15.14 705 2 3
7 13 54.32 5 15.21 407 2 3
8 8 -0.04 165 15.17 314 2 2

Cycle 98 GMT 8/11/2021 20:26: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 55 15.06 508 2 3
2 7 2118.56 38 14.78 2961 2 3
3 13 1706.24 20 14.84 2482 2 2
4 13 1434.96 20 14.86 2156 2 2
5 13 890.52 20 14.97 1479 2 2
6 13 497.80 20 15.06 994 2 3
7 13 95.12 6 15.18 473 2 3
8 13 17.44 20 15.18 336 2 2
9 8 0.24 165 15.14 312 2 2
10 14 0.24 35 15.12 314 2 2

Cycle 97 GMT 8/11/2021 3:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 55 15.05 513 2 3
2 7 2116.44 39 14.75 2955 2 2
3 13 1397.12 20 14.89 2118 2 2
4 13 988.68 20 14.95 1599 2 3
5 13 401.36 20 15.10 865 2 3
6 8 0.00 165 15.16 315 2 2
7 14 0.00 35 15.14 321 2 3

Cycle 96 GMT 7/11/2021 14:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 55 15.06 523 2 2
2 7 2111.52 39 14.76 2950 2 3
3 13 1396.64 20 14.89 2099 2 2
4 13 973.92 20 14.97 1568 2 2
5 13 549.04 20 15.06 1044 2 4
6 13 64.96 6 15.19 427 2 3
7 8 0.32 165 15.15 321 2 2
8 14 0.32 35 15.12 323 2 2

Cycle 95 GMT 6/11/2021 23:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 55 15.07 487 2 2
2 7 2115.84 38 14.79 2959 2 2
3 13 1692.80 20 14.85 2474 2 3
4 13 1010.76 20 14.98 1639 2 3
5 13 468.84 20 15.09 966 2 4
6 13 79.92 6 15.19 474 2 3
7 8 0.20 165 15.15 342 2 2

Cycle 94 GMT 6/11/2021 7:34:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 55 15.10 512 2 2
2 7 2110.88 39 14.78 2960 2 2
3 13 1685.04 20 14.85 2449 2 2
4 13 1264.16 20 14.90 1945 2 2
5 13 824.28 20 14.98 1410 2 3
6 13 379.36 14 15.10 854 2 3
7 13 49.44 5 15.20 399 2 2
8 8 0.12 165 15.16 321 2 2

Cycle 93 GMT 5/11/2021 17:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 55 15.08 507 2 2
2 5 2086.40 9 14.89 3038 2 2
3 7 2107.40 38 14.83 2950 2 3
4 13 1663.40 20 14.90 2431 2 2
5 13 1250.84 20 14.95 1908 2 3
6 13 976.88 20 14.98 1588 2 3
7 13 406.60 20 15.14 870 2 4
8 13 68.96 6 15.23 429 2 3
9 13 43.68 5 15.24 383 2 2
10 8 0.56 165 15.20 319 2 2
11 14 0.56 35 15.18 323 2 2

Cycle 92 GMT 27/10/2021 1:18: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 55 15.10 492 2 3
2 7 2110.60 38 14.82 2954 2 3
3 13 1711.00 20 14.88 2485 2 2
4 13 1441.36 20 14.88 2155 2 2
5 13 862.16 20 15.00 1454 2 3
6 13 411.64 20 15.12 875 2 3
7 13 18.64 10 15.23 333 2 2
8 8 0.00 165 15.17 317 2 2

Cycle 91 GMT 26/10/2021 5:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 55 15.06 508 2 2
2 7 2113.96 38 14.80 2947 2 2
3 13 1533.00 20 14.90 2271 2 2
4 13 804.92 20 15.05 1365 2 4
5 13 224.24 10 15.20 630 2 3
6 13 48.12 5 15.24 387 2 3
7 8 0.08 165 15.19 324 2 2

Cycle 90 GMT 25/10/2021 10:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 55 15.06 506 2 2
2 7 2117.32 38 14.75 2953 2 3
3 13 1515.64 20 14.87 2248 2 2
4 13 943.28 20 14.98 1543 2 2
5 13 410.00 20 15.11 870 2 3
6 13 67.28 6 15.20 423 2 2
7 8 0.08 165 15.17 311 2 2

Cycle 89 GMT 24/10/2021 20: 9: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 55 15.11 495 2 2
2 7 2106.84 38 14.77 2948 2 2
3 13 1500.96 20 14.90 2239 2 3
4 13 1047.48 20 14.96 1684 2 2
5 13 618.20 20 15.04 1155 2 3
6 13 92.56 6 15.19 485 2 2
7 13 60.60 5 15.21 434 2 2
8 8 0.28 165 15.16 329 2 2
9 14 0.28 35 15.13 327 2 3

Cycle 88 GMT 24/10/2021 6:30:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 55 15.13 503 2 2
2 7 2113.76 38 14.81 2957 2 3
3 13 1499.60 20 14.91 2220 2 2
4 13 946.84 20 15.02 1534 2 3
5 13 553.08 20 15.10 1040 2 3
6 13 116.48 7 15.21 490 2 3
7 8 0.12 165 15.19 308 2 2

Cycle 87 GMT 23/10/2021 12: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 55 15.08 518 2 3
2 5 2077.24 9 14.89 3057 2 2
3 7 2106.96 38 14.83 2950 2 3
4 13 1387.36 20 14.95 2081 2 2
5 13 942.32 20 15.02 1531 2 2
6 13 499.28 20 15.13 978 2 3
7 13 44.92 5 15.27 375 2 2
8 13 15.28 20 15.26 337 2 2
9 8 0.28 165 15.21 316 2 2

Cycle 86 GMT 13/10/2021 19:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 55 15.11 511 2 2
2 7 2117.16 38 14.81 2952 2 2
3 13 1705.60 20 14.87 2469 2 2
4 13 1285.16 20 14.93 1959 2 3
5 13 882.72 20 15.00 1479 2 3
6 13 444.28 20 15.09 920 2 3
7 13 44.80 5 15.24 384 2 2
8 13 42.48 5 15.23 382 2 2
9 13 18.32 11 15.21 344 2 2
10 8 -0.16 165 15.17 315 2 2

Cycle 85 GMT 12/10/2021 23:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 55 15.08 522 2 2
2 5 2079.40 9 14.90 3025 2 2
3 7 2119.04 38 14.80 2961 2 3
4 13 1402.20 20 14.93 2101 2 2
5 13 976.80 20 15.00 1567 2 3
6 13 402.32 20 15.14 850 2 3
7 8 0.16 165 15.20 300 2 2

Cycle 84 GMT 12/10/2021 3:22:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 55 15.08 503 2 3
2 7 2111.96 38 14.81 2952 2 3
3 13 1400.44 20 14.92 2091 2 2
4 13 994.84 20 15.00 1596 2 3
5 13 448.48 20 15.12 909 2 3
6 13 81.04 6 15.21 455 2 3
7 8 0.16 165 15.18 340 2 2

Cycle 83 GMT 11/10/2021 8:50: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 55 15.08 518 2 3
2 7 2108.68 38 14.77 2947 2 2
3 13 1372.72 20 14.91 2062 2 2
4 13 965.24 20 14.98 1562 2 3
5 13 550.52 20 15.07 1052 2 3
6 13 120.52 7 15.19 498 2 2
7 8 0.04 165 15.17 313 2 2

Cycle 82 GMT 10/10/2021 18:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 55 15.09 514 2 2
2 7 2113.56 38 14.77 2953 2 3
3 13 1689.68 20 14.85 2453 2 2
4 13 1085.40 20 14.96 1707 2 3
5 13 649.28 20 15.05 1162 2 3
6 13 100.56 7 15.20 472 2 3
7 8 0.04 165 15.17 327 2 2

Cycle 81 GMT 10/10/2021 3:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 55 15.08 508 2 2
2 7 2106.56 38 14.82 2947 2 3
3 13 1510.44 20 14.91 2246 2 3
4 13 939.80 20 15.01 1557 2 2
5 13 544.32 20 15.09 1048 2 3
6 13 121.00 7 15.21 532 2 3
7 8 0.16 165 15.19 331 2 2

Cycle 80 GMT 9/10/2021 8:10: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 55 15.09 509 2 2
2 7 2110.76 38 14.77 2956 2 3
3 13 1510.28 20 14.88 2233 2 3
4 13 897.44 20 15.01 1474 2 3
5 13 326.28 13 15.14 772 2 2
6 13 60.12 5 15.22 416 2 2
7 8 0.08 165 15.17 321 2 2

Cycle 79 GMT 8/10/2021 17:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 55 15.11 506 2 2
2 7 2115.96 38 14.78 2960 2 3
3 13 1386.12 20 14.91 2072 2 3
4 13 798.64 20 15.05 1354 2 3
5 13 231.08 10 15.18 652 2 3
6 13 113.40 7 15.20 506 2 3
7 8 0.08 165 15.18 321 2 2

Cycle 78 GMT 8/10/2021 2:59: 3

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 55 15.11 513 2 3
2 7 2111.40 38 14.79 2962 2 2
3 13 1491.48 20 14.91 2213 2 2
4 13 769.40 20 15.06 1314 2 3
5 13 198.32 9 15.20 594 2 3
6 8 0.00 165 15.19 318 2 2

Cycle 77 GMT 7/10/2021 10:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 55 15.10 522 2 3
2 7 2111.56 38 14.82 2958 2 2
3 13 1484.28 20 14.93 2206 2 2
4 13 1060.04 20 15.00 1678 2 2
5 13 495.08 20 15.12 968 2 3
6 13 98.92 7 15.22 467 2 3
7 8 0.16 165 15.20 309 2 2

Cycle 76 GMT 6/10/2021 14:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 55 15.11 498 2 3
2 7 2109.40 38 14.80 2951 2 3
3 13 1696.56 20 14.86 2458 2 3
4 13 1113.68 20 14.97 1759 2 3
5 13 510.32 20 15.10 1020 2 4
6 13 59.64 5 15.23 437 2 2
7 8 0.00 165 15.18 348 2 2

Cycle 75 GMT 5/10/2021 21:38:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 55 15.10 509 2 2
2 7 2113.68 38 14.80 2956 2 2
3 13 1383.00 20 14.94 2083 2 2
4 13 971.88 20 15.01 1564 2 3
5 13 543.76 20 15.10 1028 2 3
6 13 19.76 12 15.24 335 2 2
7 8 0.00 165 15.19 317 2 2

Cycle 74 GMT 5/10/2021 4:18:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 55 15.03 514 2 2
2 7 2115.28 38 14.80 2955 2 2
3 13 1385.80 20 14.95 2091 2 3
4 13 975.36 20 15.01 1573 2 2
5 13 553.24 20 15.09 1058 2 3
6 13 109.36 7 15.21 498 2 3
7 8 0.32 165 15.20 316 2 2
8 14 0.32 35 15.17 318 2 2

Cycle 73 GMT 4/10/2021 8:15: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 55 15.07 499 2 2
2 7 2110.68 38 14.75 2954 2 2
3 13 1668.32 20 14.84 2437 2 2
4 13 1412.56 20 14.86 2113 2 2
5 13 1010.60 20 14.94 1616 2 3
6 13 580.24 20 15.04 1097 2 3
7 13 146.36 8 15.14 560 2 2
8 13 54.04 5 15.17 423 2 3
9 13 16.76 20 15.17 366 2 2
10 8 5.56 165 15.12 343 2 2
11 14 5.56 35 15.11 339 2 2

Cycle 72 GMT 3/10/2021 17:56: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.48 55 15.05 522 2 2
2 7 2105.96 39 14.75 2935 2 2
3 13 1493.76 20 14.88 2230 2 3
4 13 1082.56 20 14.93 1717 2 3
5 13 659.68 20 15.03 1196 2 3
6 13 111.32 7 15.18 500 2 2
7 8 -0.08 165 15.15 321 2 2
8 14 -0.08 35 15.14 322 2 2

Cycle 71 GMT 3/10/2021 4:10:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 55 15.08 494 2 2
2 7 2111.00 38 14.77 2960 2 3
3 13 1675.20 20 14.83 2437 2 2
4 13 1277.08 20 14.90 1942 2 2
5 13 711.36 20 15.02 1242 2 2
6 13 158.28 8 15.17 549 2 2
7 13 19.32 8 15.20 338 2 2
8 8 0.36 165 15.16 323 2 2
9 14 0.36 35 15.13 325 2 2

Cycle 70 GMT 2/10/2021 13:45: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 55 15.10 528 2 3
2 7 2105.92 38 14.78 2948 2 2
3 13 1700.60 20 14.84 2467 2 2
4 13 1312.28 20 14.90 1985 2 3
5 13 1032.44 20 14.95 1644 2 3
6 13 498.68 20 15.08 969 2 3
7 13 105.76 7 15.19 485 2 3
8 8 0.12 165 15.16 302 2 2
9 14 0.12 35 15.14 316 2 2

Cycle 69 GMT 1/10/2021 22:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 55 15.11 510 2 3
2 7 2112.96 38 14.81 2956 2 3
3 13 1392.64 20 14.96 2095 2 2
4 13 975.88 20 15.02 1584 2 3
5 13 556.20 20 15.11 1061 2 3
6 13 59.60 5 15.24 434 2 2
7 13 30.80 5 15.25 396 2 2
8 13 18.60 11 15.24 376 2 2
9 8 -0.08 165 15.19 346 2 2
10 14 -0.08 35 15.17 344 2 2

Cycle 68 GMT 1/10/2021 3:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 55 15.09 509 2 2
2 7 2106.60 38 14.82 2951 2 2
3 13 1679.68 20 14.90 2450 2 2
4 13 1255.56 20 14.95 1918 2 2
5 13 833.32 20 15.03 1398 2 3
6 13 404.16 20 15.14 861 2 3
7 13 17.16 20 15.24 333 2 2
8 8 0.16 165 15.19 314 2 2

Cycle 67 GMT 30/ 9/2021 7:13: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 55 15.09 499 2 3
2 7 2110.60 39 14.79 2961 2 3
3 13 1396.28 20 14.93 2102 2 3
4 13 991.68 20 15.00 1597 2 3
5 13 427.64 20 15.13 883 2 3
6 8 -0.04 165 15.19 315 2 2
7 14 -0.04 35 15.17 320 2 2

Cycle 66 GMT 29/ 9/2021 13:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 55 15.10 511 2 3
2 7 2113.88 38 14.78 2953 2 3
3 13 1382.12 20 14.93 2071 2 3
4 13 962.80 20 15.00 1565 2 2
5 13 541.68 20 15.08 1038 2 3
6 13 67.20 6 15.21 423 2 2
7 8 0.08 165 15.19 313 2 4

Cycle 65 GMT 28/ 9/2021 23:42: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 55 15.12 501 2 3
2 7 2107.80 38 14.83 2947 2 3
3 13 1669.40 20 14.90 2429 2 2
4 13 1098.88 20 14.99 1731 2 3
5 13 520.72 20 15.12 1039 2 3
6 8 0.16 165 15.21 318 2 2
7 14 0.16 35 15.18 320 2 2

Cycle 64 GMT 28/ 9/2021 3:44: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 55 15.08 509 2 3
2 7 2106.80 38 14.82 2949 2 3
3 13 1355.96 20 14.95 2047 2 3
4 13 786.60 20 15.06 1341 2 2
5 13 208.32 10 15.21 606 2 3
6 13 61.00 5 15.25 409 2 2
7 13 48.64 5 15.25 380 2 2
8 13 8.96 20 15.24 318 2 2
9 8 0.12 165 15.20 317 2 2
10 14 0.12 35 15.17 320 2 2

Cycle 63 GMT 27/ 9/2021 8:11: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 55 15.04 506 2 2
2 7 2110.24 38 14.79 2952 2 3
3 13 1497.20 20 14.90 2225 2 2
4 13 1071.12 20 14.97 1694 2 2
5 13 652.44 20 15.05 1192 2 3
6 13 199.44 9 15.18 626 2 3
7 8 0.12 165 15.17 324 2 2

Cycle 62 GMT 26/ 9/2021 14:57: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 55 15.06 521 2 3
2 7 2111.44 38 14.76 2943 2 2
3 13 1697.88 20 14.84 2469 2 2
4 13 1434.96 20 14.85 2149 2 2
5 13 1028.72 20 14.93 1650 2 2
6 13 614.40 20 15.02 1140 2 3
7 13 84.48 6 15.16 471 2 2
8 13 46.28 5 15.18 403 2 2
9 8 0.16 165 15.13 326 2 2
10 14 0.16 35 15.11 327 2 2

Cycle 61 GMT 26/ 9/2021 0:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 55 15.11 507 2 3
2 7 2111.48 38 14.78 2956 2 3
3 13 1696.84 20 14.86 2474 2 2
4 13 1300.76 20 14.91 2008 2 3
5 13 881.16 20 14.99 1497 2 2
6 13 314.04 13 15.14 772 2 3
7 13 55.48 5 15.21 410 2 2
8 8 0.40 165 15.17 323 2 2
9 14 0.40 35 15.15 326 2 2

Cycle 60 GMT 25/ 9/2021 10:14:58

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 55 15.10 494 2 3
2 7 2106.12 38 14.82 2943 2 2
3 13 1374.80 20 14.95 2065 2 2
4 13 805.64 20 15.06 1363 2 3
5 13 243.40 11 15.20 663 2 2
6 13 68.80 6 15.24 436 2 3
7 8 0.12 165 15.21 326 2 2

Cycle 59 GMT 24/ 9/2021 14:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 55 15.11 515 2 2
2 7 2111.76 39 14.80 2956 2 3
3 13 1378.32 20 14.93 2078 2 2
4 13 939.56 20 15.01 1537 2 3
5 13 498.80 20 15.11 976 2 3
6 13 40.20 5 15.24 372 2 2
7 8 0.16 165 15.19 327 2 2
8 14 0.16 35 15.17 327 2 2

Cycle 58 GMT 23/ 9/2021 20:58: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 55 15.10 512 2 3
2 7 2111.64 38 14.81 2950 2 2
3 13 1686.60 20 14.87 2460 2 2
4 13 1266.64 20 14.93 1942 2 3
5 13 655.44 20 15.06 1188 2 3
6 13 113.00 7 15.22 518 2 3
7 8 0.28 165 15.19 329 2 2

Cycle 57 GMT 23/ 9/2021 3:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 55 15.10 504 2 3
2 7 2109.44 38 14.79 2955 2 3
3 13 1389.88 20 14.93 2089 2 2
4 13 1095.92 20 14.97 1719 2 2
5 13 239.44 10 15.19 662 2 3
6 13 121.48 7 15.21 515 2 3
7 8 0.12 165 15.19 321 2 2

Cycle 56 GMT 22/ 9/2021 10:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 55 15.07 503 2 2
2 7 2111.64 38 14.79 2958 2 3
3 13 1494.32 20 14.90 2218 2 2
4 13 759.92 20 15.06 1312 2 3
5 13 328.44 13 15.15 769 2 3
6 13 91.68 6 15.21 475 2 3
7 8 -0.04 165 15.19 320 2 2

Cycle 55 GMT 21/ 9/2021 17:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 55 15.04 506 2 3
2 7 2108.44 39 14.76 2943 2 3
3 13 1500.16 20 14.87 2230 2 3
4 13 773.76 20 15.03 1323 2 3
5 13 332.40 13 15.12 766 2 3
6 13 17.52 20 15.21 333 2 2
7 8 0.16 165 15.16 320 2 2

Cycle 54 GMT 21/ 9/2021 3:36: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 55 15.09 502 2 2
2 7 2108.96 38 14.77 2952 2 2
3 13 1661.12 20 14.85 2414 2 2
4 13 1237.20 20 14.90 1905 2 3
5 13 827.60 20 14.99 1389 2 3
6 13 416.88 20 15.08 877 2 3
7 13 47.68 5 15.18 397 2 2
8 8 0.00 165 15.14 320 2 2
9 14 0.00 35 15.12 319 2 2

Cycle 53 GMT 20/ 9/2021 13:23:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 55 15.13 496 2 2
2 7 2111.48 38 14.78 2953 2 2
3 13 1678.16 20 14.85 2450 2 2
4 13 1262.08 20 14.92 1924 2 2
5 13 991.84 20 14.96 1595 2 3
6 13 383.72 15 15.13 829 2 3
7 8 0.08 165 15.18 300 2 2

Cycle 52 GMT 19/ 9/2021 23:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 55 15.09 493 2 2
2 7 2110.52 38 14.82 2959 2 2
3 13 1510.68 20 14.94 2235 2 2
4 13 938.08 20 15.03 1531 2 3
5 13 507.44 20 15.13 988 2 3
6 13 93.72 6 15.23 465 2 2
7 8 -0.04 165 15.21 302 2 2

Cycle 51 GMT 19/ 9/2021 3:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 55 15.08 475 2 2
2 7 2113.92 38 14.78 2951 2 3
3 13 1502.96 20 14.89 2229 2 2
4 13 1078.16 20 14.96 1707 2 3
5 13 518.48 20 15.07 1003 2 3
6 13 62.12 6 15.21 414 2 3
7 8 0.12 165 15.18 308 2 2

Cycle 50 GMT 18/ 9/2021 12:51: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 55 15.13 466 2 2
2 5 2100.20 9 14.89 3053 2 2
3 7 2108.28 38 14.78 2944 2 2
4 13 1676.52 20 14.86 2431 2 2
5 13 1402.08 20 14.89 2100 2 2
6 13 858.96 20 15.00 1428 2 3
7 13 328.96 13 15.14 758 2 3
8 13 96.80 6 15.20 471 2 2
9 13 48.28 5 15.22 388 2 2
10 8 0.16 165 15.18 304 2 2
11 14 0.16 35 15.16 305 2 2

Cycle 49 GMT 17/ 9/2021 20:19: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 55 15.10 476 2 2
2 7 2111.52 38 14.83 2951 2 3
3 13 1384.36 20 14.96 2086 2 2
4 13 952.08 20 15.04 1545 2 3
5 13 395.76 15 15.16 853 2 3
6 13 123.88 7 15.23 508 2 3
7 8 0.40 165 15.22 303 2 2
8 14 0.40 35 15.21 303 2 2

Cycle 48 GMT 16/ 9/2021 22:47:59

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 55 15.13 474 2 2
2 7 2110.60 38 14.78 2950 2 3
3 13 1520.24 20 14.90 2250 2 2
4 13 957.96 20 15.00 1546 2 3
5 13 407.00 20 15.13 856 2 3
6 13 60.92 5 15.23 414 2 3
7 13 43.36 5 15.23 378 2 2
8 8 0.12 165 15.20 302 2 2
9 14 0.12 35 15.17 303 2 2

Cycle 47 GMT 16/ 9/2021 8: 7: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 55 15.10 496 2 3
2 7 2106.48 38 14.82 2942 2 2
3 13 1693.92 20 14.89 2464 2 2
4 13 1427.72 20 14.92 2134 2 2
5 13 846.00 20 15.04 1411 2 3
6 13 391.60 15 15.14 838 2 3
7 13 48.88 5 15.24 390 2 2
8 8 0.44 165 15.20 302 2 2

Cycle 46 GMT 15/ 9/2021 11:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 55 15.13 475 2 2
2 7 2110.28 38 14.79 2949 2 2
3 13 1397.96 20 14.92 2102 2 2
4 13 826.80 20 15.03 1390 2 2
5 13 260.28 11 15.18 676 2 3
6 13 44.44 5 15.23 374 2 2
7 13 19.16 13 15.22 329 2 2
8 8 0.24 165 15.19 299 2 2
9 14 0.24 35 15.17 299 2 2

Cycle 45 GMT 14/ 9/2021 20:49: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 55 15.13 479 2 3
2 7 2111.20 38 14.80 2959 2 2
3 13 1501.68 20 14.91 2230 2 3
4 13 881.04 20 15.03 1458 2 3
5 13 275.68 11 15.18 692 2 2
6 13 85.16 6 15.23 458 2 3
7 8 0.00 165 15.21 303 2 2
8 14 0.00 35 15.19 304 2 2

Cycle 44 GMT 14/ 9/2021 6: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 55 15.17 481 2 3
2 7 2108.68 38 14.81 2952 2 2
3 13 1507.08 20 14.92 2243 2 3
4 13 938.20 20 15.03 1531 2 3
5 13 362.52 14 15.17 806 2 3
6 13 111.28 7 15.23 492 2 2
7 8 -0.04 165 15.22 302 2 2
8 14 -0.04 35 15.19 302 2 2

Cycle 43 GMT 13/ 9/2021 15:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 55 15.18 471 2 2
2 5 2100.04 9 14.92 3087 2 2
3 7 2108.16 38 14.89 2946 2 3
4 13 1391.24 20 15.00 2090 2 2
5 13 979.64 20 15.06 1582 2 3
6 13 551.24 20 15.15 1040 2 3
7 13 115.32 7 15.28 493 2 2
8 8 0.16 165 15.26 299 2 2
9 14 0.16 35 15.24 301 2 2

Cycle 42 GMT 3/ 9/2021 22:27: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 55 15.16 487 2 2
2 7 2094.24 38 14.91 2934 2 2
3 13 1351.72 20 15.03 2045 2 2
4 13 774.76 20 15.13 1319 2 3
5 13 164.04 8 15.28 553 2 2
6 8 1.88 165 15.29 299 2 2
7 14 1.88 35 15.27 300 2 2

Cycle 41 GMT 25/ 8/2021 1:38: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 55 15.18 499 2 2
2 7 2108.60 39 14.84 2952 2 2
3 13 1364.72 20 14.99 2061 2 2
4 13 933.12 20 15.05 1524 2 2
5 13 358.16 14 15.21 803 2 2
6 13 104.44 7 15.28 481 2 2
7 8 -0.12 165 15.25 301 2 2

Cycle 40 GMT 24/ 8/2021 8:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 55 15.13 482 2 2
2 5 2103.56 9 14.92 3111 2 2
3 7 2106.56 38 14.90 2947 2 2
4 13 1510.44 20 14.99 2241 2 2
5 13 930.64 20 15.10 1520 2 2
6 13 504.16 20 15.19 986 2 2
7 13 58.40 5 15.31 414 2 2
8 8 0.16 165 15.28 304 2 3
9 14 0.16 35 15.26 304 2 2

Cycle 39 GMT 14/ 8/2021 15:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 55 15.14 491 2 2
2 5 2104.96 9 14.90 3099 2 2
3 7 2110.28 38 14.81 2953 2 2
4 13 1376.72 20 14.96 2076 2 2
5 13 949.44 20 15.03 1543 2 2
6 13 509.12 20 15.14 998 2 2
7 13 94.16 6 15.25 471 2 2
8 8 0.00 165 15.23 304 2 2

Cycle 38 GMT 13/ 8/2021 19:28: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 55 15.18 488 2 3
2 7 2105.48 38 14.85 2955 2 2
3 13 1689.24 20 14.93 2447 2 2
4 13 1414.52 20 14.94 2115 2 2
5 13 838.32 20 15.07 1403 2 2
6 13 260.64 11 15.22 677 2 2
7 13 132.56 7 15.25 518 2 2
8 8 -0.04 165 15.24 301 2 2
9 14 -0.04 35 15.22 301 2 2

Cycle 37 GMT 12/ 8/2021 21:23: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 55 15.19 481 2 2
2 7 2107.44 38 14.86 2952 2 2
3 13 1368.88 20 15.00 2062 2 2
4 13 675.28 20 15.14 1198 2 2
5 13 249.64 11 15.25 660 2 2
6 8 0.08 165 15.27 299 2 2

Cycle 36 GMT 11/ 8/2021 23:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 55 15.19 491 2 3
2 5 2102.72 9 14.91 3093 2 2
3 7 2106.80 38 14.90 2952 2 2
4 13 1380.20 18 15.03 2078 2 2
5 13 1095.40 18 15.06 1730 2 2
6 13 656.32 18 15.15 1184 2 2
7 13 112.72 7 15.30 492 2 2
8 13 17.60 18 15.31 330 2 2
9 8 0.00 165 15.27 304 2 2

Cycle 35 GMT 2/ 8/2021 7: 7: 2

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 55 15.17 477 2 2
2 5 2104.52 9 14.94 3134 2 2
3 7 2107.28 38 14.91 2945 2 2
4 13 1690.96 18 14.97 2454 2 2
5 13 1150.40 18 15.06 1791 2 2
6 13 743.24 18 15.14 1292 2 2
7 13 340.12 13 15.23 781 2 2
8 13 102.52 7 15.30 477 2 2
9 8 0.24 165 15.29 303 2 2

Cycle 34 GMT 23/ 7/2021 14: 4: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 55 15.21 478 2 2
2 5 2099.00 9 14.93 3086 2 2
3 7 2109.16 38 14.84 2964 2 2
4 13 1388.96 18 14.99 2086 2 2
5 13 965.60 18 15.05 1564 2 2
6 13 693.60 18 15.11 1223 2 2
7 13 139.08 8 15.27 520 2 2
8 13 77.08 6 15.27 438 2 2
9 8 0.44 165 15.25 298 2 2

Cycle 33 GMT 22/ 7/2021 21:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 55 15.13 490 2 2
2 5 2104.08 9 14.91 3095 2 2
3 7 2106.24 38 14.91 2944 2 2
4 13 1368.56 18 15.05 2059 2 2
5 13 968.92 18 15.11 1565 2 2
6 13 548.04 18 15.20 1032 2 2
7 13 64.32 6 15.34 412 2 3
8 8 -0.16 165 15.31 297 2 2

Cycle 32 GMT 13/ 7/2021 4:24: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 55 15.15 480 2 2
2 5 2104.96 9 14.89 3077 2 2
3 7 2105.28 38 14.82 2942 2 2
4 13 1500.44 18 14.93 2224 2 2
5 13 1092.20 18 15.00 1710 2 2
6 13 668.16 18 15.09 1194 2 2
7 13 232.48 10 15.20 641 2 2
8 13 47.32 5 15.26 386 2 2
9 8 0.08 165 15.23 299 2 2
10 14 0.08 35 15.21 300 2 2

Cycle 31 GMT 12/ 7/2021 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 55 15.19 495 2 2
2 5 2101.12 9 14.92 3059 2 2
3 7 2105.36 39 14.83 2952 2 2
4 13 1670.32 18 14.92 2434 2 2
5 13 1252.44 18 14.98 1922 2 2
6 13 681.96 18 15.11 1215 2 2
7 13 263.48 11 15.22 676 2 2
8 13 50.16 5 15.27 392 2 2
9 8 0.04 165 15.25 299 2 2
10 14 0.04 35 15.22 301 2 2

Cycle 30 GMT 11/ 7/2021 18:40: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 55 15.22 480 2 2
2 7 2107.28 38 14.89 2943 2 2
3 13 1386.76 18 15.02 2091 2 2
4 13 974.36 18 15.09 1575 2 2
5 13 430.88 18 15.21 888 2 2
6 13 70.36 6 15.31 428 2 2
7 8 0.12 165 15.29 301 2 2
8 14 0.12 35 15.27 302 2 2

Cycle 29 GMT 10/ 7/2021 22: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 55 15.16 477 2 2
2 5 2088.24 9 14.91 3074 2 2
3 5 2104.36 9 14.92 3109 2 2
4 7 2106.12 38 14.92 2942 2 2
5 13 1363.68 18 15.06 2053 2 2
6 13 948.84 18 15.12 1544 2 2
7 13 395.64 15 15.26 842 2 2
8 13 114.32 7 15.33 489 2 2
9 8 -0.12 165 15.32 302 2 3

Cycle 28 GMT 1/ 7/2021 5:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 55 15.18 488 2 2
2 5 2100.00 9 14.92 3054 2 2
3 7 2106.56 39 14.83 2956 2 2
4 13 1507.20 18 14.95 2236 2 2
5 13 938.56 18 15.06 1527 2 2
6 13 372.68 14 15.20 827 2 2
7 13 107.88 7 15.27 484 2 3
8 13 43.12 5 15.28 382 2 2
9 8 0.32 165 15.25 302 2 2

Cycle 27 GMT 30/ 6/2021 11:52: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 55 15.24 481 2 2
2 7 2107.08 38 14.87 2943 2 2
3 13 1501.40 18 14.99 2231 2 2
4 13 951.44 18 15.10 1547 2 2
5 13 561.16 18 15.17 1056 2 2
6 13 153.04 8 15.27 540 2 2
7 13 54.96 5 15.31 406 2 2
8 13 17.12 18 15.31 333 2 2
9 8 0.12 165 15.26 300 2 2

Cycle 26 GMT 29/ 6/2021 18: 0: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 55 15.20 472 2 3
2 5 2081.72 9 14.94 3080 2 2
3 5 2101.16 9 14.93 3085 2 2
4 7 2105.96 38 14.93 2955 2 2
5 13 1505.96 18 15.04 2235 2 2
6 13 922.76 18 15.15 1509 2 2
7 13 489.40 18 15.23 972 2 2
8 13 61.80 6 15.36 424 2 3
9 8 0.40 165 15.33 306 2 2
10 14 0.40 35 15.31 306 2 2

Cycle 25 GMT 20/ 6/2021 1:16: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 55 15.22 498 2 2
2 5 2101.04 9 14.99 3106 2 2
3 7 2105.08 39 14.89 2944 2 2
4 13 1511.52 18 15.00 2243 2 2
5 13 905.20 18 15.12 1497 2 2
6 13 310.24 12 15.27 740 2 2
7 13 85.60 6 15.32 454 2 3
8 8 -0.12 165 15.30 304 2 2
9 14 -0.12 35 15.27 304 2 2

Cycle 24 GMT 18/ 6/2021 23:42: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 55 15.23 480 2 3
2 5 2095.44 9 14.99 3081 2 2
3 7 2108.24 38 14.93 2953 2 2
4 13 1276.12 18 15.10 1949 2 2
5 13 1003.24 18 15.12 1613 2 2
6 13 553.88 18 15.21 1046 2 2
7 13 17.00 18 15.36 334 2 2
8 8 0.24 165 15.32 307 2 2
9 14 0.24 35 15.30 307 2 2

Cycle 23 GMT 9/ 6/2021 6: 9: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 55 15.25 485 2 2
2 5 2088.76 9 14.98 3115 2 2
3 7 2106.56 38 14.94 2954 2 2
4 13 1371.76 18 15.07 2071 2 2
5 13 813.72 18 15.18 1378 2 2
6 13 386.64 15 15.27 839 2 2
7 13 63.52 6 15.36 422 2 2
8 8 -0.16 165 15.33 305 2 2
9 14 -0.16 35 15.31 304 2 2

Cycle 22 GMT 30/ 5/2021 13:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 55 15.22 486 2 2
2 5 2096.08 9 14.96 3078 2 2
3 5 2098.52 9 14.96 3100 2 2
4 5 2102.88 9 14.96 3099 2 2
5 7 2106.00 38 14.93 2959 2 2
6 13 1694.60 18 15.00 2482 2 2
7 13 1130.12 18 15.10 1778 2 2
8 13 562.88 18 15.22 1059 2 2
9 13 132.24 7 15.34 521 2 3
10 13 52.36 5 15.35 402 2 2
11 8 0.16 165 15.33 302 2 2

Cycle 21 GMT 20/ 5/2021 19:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 55 15.23 491 2 2
2 5 2091.76 9 14.96 3063 2 2
3 7 2102.84 39 14.94 2945 2 2
4 13 1682.48 18 15.02 2460 2 2
5 13 1129.36 18 15.11 1768 2 2
6 13 579.52 18 15.23 1082 2 2
7 13 150.56 8 15.34 539 2 2
8 13 54.04 5 15.36 404 2 2
9 13 41.08 5 15.36 382 2 2
10 13 16.08 18 15.36 330 2 2
11 8 0.16 165 15.32 302 2 2

Cycle 20 GMT 10/ 5/2021 22:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 55 15.26 486 2 2
2 5 2091.80 9 15.03 3098 2 2
3 7 2104.28 38 14.94 2945 2 2
4 13 1374.60 18 15.08 2078 2 2
5 13 948.72 18 15.16 1550 2 2
6 13 523.12 18 15.25 1018 2 2
7 13 122.60 7 15.36 516 2 3
8 13 50.84 5 15.36 413 2 2
9 8 0.16 165 15.33 310 2 2

Cycle 19 GMT 1/ 5/2021 1:46: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 45 15.25 490 2 2
2 10 1830.84 4 15.04 2751 2 2
3 10 1882.56 3 15.06 2814 2 2
4 10 1918.72 2 15.06 2869 2 2
5 10 1994.60 2 15.05 2965 2 2
6 3 1994.96 7 14.97 2933 2 2
7 3 2093.48 10 14.92 3078 2 2
8 7 2100.48 38 14.94 2949 2 2
9 13 1364.16 18 15.09 2065 2 2
10 13 955.96 18 15.16 1554 2 2
11 13 520.76 18 15.24 1007 2 2
12 13 97.52 7 15.36 482 2 3
13 8 0.04 165 15.34 309 2 2
14 14 0.04 35 15.32 309 2 2

Cycle 18 GMT 21/ 4/2021 3:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 46 15.26 488 2 2
2 3 1191.48 -11 15.63 1 2 2
3 3 1889.92 4 15.08 2838 2 2
4 5 2088.04 10 14.97 3096 2 2
5 7 2098.64 38 14.96 2953 2 2
6 13 1503.04 18 15.08 2242 2 2
7 13 943.48 18 15.18 1547 2 2
8 13 420.60 18 15.29 887 2 2
9 13 77.96 6 15.38 453 2 2
10 13 55.96 5 15.39 418 2 2
11 8 -0.16 165 15.36 309 2 3
12 14 -0.16 35 15.34 310 2 2

Cycle 17 GMT 11/ 4/2021 2: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 36 15.28 490 2 2
2 10 1799.64 4 15.09 2703 2 2
3 10 1843.88 3 15.09 2802 2 2
4 3 1844.44 3 15.07 2733 2 2
5 3 2081.36 9 14.97 3068 2 2
6 5 2086.60 9 14.95 3053 2 2
7 5 2092.44 10 14.96 3081 2 2
8 5 2092.36 10 14.98 3132 2 2
9 7 2102.08 38 14.97 2953 2 2
10 13 1377.84 18 15.10 2075 2 2
11 13 704.00 18 15.24 1246 2 2
12 13 304.80 12 15.32 737 2 2
13 13 89.04 6 15.38 470 2 2
14 8 0.28 165 15.35 313 2 2

Cycle 16 GMT 1/ 4/2021 4: 8: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 30 15.30 478 2 2
2 10 1766.96 4 15.07 2648 2 2
3 10 1811.92 3 15.08 2720 2 2
4 10 1844.76 2 15.07 2770 2 2
5 10 1880.08 2 15.05 2820 2 2
6 3 1948.28 6 15.03 2904 2 2
7 3 1780.96 1 15.16 2704 2 2
8 7 2086.40 38 14.98 2938 2 2
9 13 1472.84 18 15.09 2202 2 2
10 13 877.48 18 15.21 1463 2 2
11 13 288.40 12 15.34 717 2 2
12 13 51.96 5 15.39 407 2 2
13 13 46.24 5 15.39 395 2 2
14 8 0.16 165 15.35 307 2 2

Cycle 15 GMT 22/ 3/2021 3:28: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 38 15.28 483 2 2
2 10 1066.24 3 15.25 1742 2 2
3 10 1099.20 2 15.25 1823 2 2
4 10 1175.00 2 15.22 1890 2 2
5 10 1213.32 2 15.23 1945 2 2
6 10 1249.44 2 15.23 1985 2 2
7 3 1261.84 7 15.19 2018 2 2
8 3 1032.68 1 15.33 1710 2 2
9 7 2004.16 38 15.00 2824 2 2
10 13 1541.16 18 15.09 2286 2 2
11 13 793.80 18 15.22 1358 2 2
12 13 355.72 14 15.33 805 2 2
13 13 62.64 6 15.40 424 2 2
14 8 -0.20 165 15.38 307 2 2
15 14 -0.20 35 15.36 303 2 2

Cycle 14 GMT 12/ 3/2021 5:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 69 15.18 486 2 2
2 2 231.00 27 15.24 642 2 2
3 10 1078.52 4 15.15 1760 2 2
4 10 1120.64 3 15.15 1817 2 2
5 10 1149.32 2 15.15 1859 2 2
6 10 1176.92 2 15.16 1897 2 2
7 10 1257.32 3 15.14 1985 2 2
8 10 1286.80 2 15.14 2050 2 2
9 10 1346.56 2 15.15 2126 2 2
10 10 1379.76 2 15.11 2174 2 2
11 3 1407.32 11 15.07 2211 2 2
12 3 1056.40 2 15.25 1731 2 2
13 7 2008.80 38 15.01 2839 2 2
14 13 1581.24 18 15.09 2333 2 2
15 13 1187.40 18 15.14 1842 2 2
16 13 758.68 18 15.22 1308 2 2
17 13 180.60 9 15.36 581 2 2
18 13 59.04 5 15.39 420 2 2
19 8 0.00 165 15.36 313 2 2

Cycle 13 GMT 2/ 3/2021 7: 5: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 55 15.22 492 2 2
2 10 1001.16 5 15.27 1682 2 2
3 10 1056.08 3 15.25 1756 2 2
4 3 1056.84 2 15.27 1725 2 2
5 3 1456.76 13 15.12 2261 2 2
6 5 1681.96 19 15.01 2536 2 2
7 7 2007.44 38 14.91 2836 2 2
8 13 1582.52 18 14.99 2345 2 2
9 13 1302.92 18 15.01 1985 2 2
10 13 705.04 18 15.16 1240 2 2
11 13 151.56 8 15.30 543 2 2
12 13 58.76 5 15.32 421 2 2
13 8 0.16 165 15.29 310 2 2

Cycle 12 GMT 1/ 3/2021 13:10: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 49 15.28 476 2 2
2 3 749.32 -5 15.65 1 2 2
3 3 1225.32 6 15.27 1959 2 2
4 5 1628.60 18 15.09 2475 2 2
5 7 2035.08 38 14.93 2872 2 2
6 13 1435.48 18 15.05 2153 2 2
7 13 993.44 18 15.13 1607 2 2
8 13 424.68 18 15.26 886 2 2
9 13 63.08 18 15.35 419 2 2
10 8 0.04 165 15.32 311 2 2

Cycle 11 GMT 28/ 2/2021 19:15: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 36 15.30 479 2 2
2 10 1000.52 3 15.27 1685 2 2
3 10 1039.24 2 15.27 1721 2 2
4 10 1069.52 2 15.27 1776 2 2
5 10 1140.28 2 15.26 1850 2 2
6 3 1176.88 5 15.25 1890 2 2
7 3 1329.52 9 15.19 2113 2 2
8 5 1572.60 16 15.10 2417 2 2
9 5 1325.92 9 15.21 2071 2 2
10 7 2002.88 38 15.03 2830 2 2
11 13 1425.76 18 15.13 2142 2 2
12 13 830.76 18 15.24 1401 2 2
13 13 395.36 18 15.33 853 2 2
14 13 51.80 18 15.41 400 2 2
15 8 0.28 165 15.38 310 2 2

Cycle 10 GMT 18/ 2/2021 21:25: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 70 15.21 491 2 2
2 2 221.32 27 15.24 632 2 2
3 10 1083.52 5 15.15 1776 2 2
4 10 1131.24 3 15.15 1836 2 2
5 10 1161.52 2 15.16 1888 2 2
6 10 1189.72 2 15.17 1942 2 2
7 10 1217.64 2 15.16 1977 2 2
8 10 1284.92 2 15.15 2071 2 2
9 10 1312.04 2 15.16 2073 2 2
10 3 1328.36 9 15.11 2088 2 2
11 3 1509.96 14 15.06 2340 2 2
12 5 1342.40 10 15.13 2130 2 2
13 5 1862.00 24 14.94 2756 2 2
14 5 1326.56 9 15.18 2079 2 2
15 7 2003.60 74 14.91 2818 2 2
16 13 345.96 18 15.36 784 2 2
17 13 43.28 18 15.43 386 2 2
18 8 -0.20 165 15.38 312 2 2

Cycle 9 GMT 9/ 2/2021 0: 6: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 70 15.26 492 2 2
2 2 209.96 27 15.33 618 2 2
3 10 1084.16 5 15.22 1767 2 2
4 10 1147.80 4 15.22 1853 2 2
5 10 1184.44 2 15.21 1906 2 2
6 10 1236.28 2 15.22 1976 2 2
7 3 1283.00 8 15.20 2029 2 2
8 3 1449.32 13 15.13 2251 2 2
9 5 1709.24 20 15.01 2559 2 2
10 7 2037.68 74 14.79 2864 2 2
11 13 724.92 18 15.16 1265 2 2
12 13 291.20 18 15.27 718 2 2
13 8 0.12 165 15.31 314 2 2

Cycle 8 GMT 8/ 2/2021 6:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 70 15.22 485 2 2
2 2 224.20 27 15.26 631 2 2
3 10 1077.80 5 15.19 1779 2 2
4 10 1121.64 3 15.20 1825 2 2
5 10 1155.88 2 15.18 1871 2 2
6 10 1185.96 2 15.18 1922 2 2
7 3 1195.52 6 15.21 1914 2 2
8 3 1455.60 13 15.12 2274 2 2
9 5 1838.56 24 14.96 2773 2 2
10 5 1346.40 10 15.18 2112 2 2
11 7 2006.16 74 14.92 2815 2 2
12 13 349.28 18 15.35 792 2 2
13 8 0.52 165 15.39 313 2 2
14 14 0.52 75 15.36 309 2 2

Cycle 7 GMT 29/ 1/2021 9: 8: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 47 15.32 486 2 2
2 3 960.64 -1 15.66 1 2 2
3 3 1416.40 12 15.18 2209 2 2
4 5 1670.48 19 15.06 2514 2 2
5 7 2018.12 74 14.83 2834 2 2
6 13 765.72 18 15.19 1320 2 2
7 13 346.52 18 15.27 789 2 2
8 8 0.08 165 15.32 309 2 3

Cycle 6 GMT 28/ 1/2021 15:39: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 64 15.19 479 2 2
2 2 219.48 27 15.24 628 2 2
3 10 1071.80 4 15.15 1746 2 2
4 10 1116.60 3 15.16 1811 2 2
5 3 1137.52 4 15.21 1859 2 2
6 3 1310.88 9 15.16 2062 2 2
7 7 2003.96 75 14.94 2808 2 2
8 13 349.12 18 15.35 787 2 2
9 8 0.12 165 15.40 310 2 2

Cycle 5 GMT 18/ 1/2021 18:52: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 15.26 476 2 2
2 10 1112.64 6 15.17 1802 2 2
3 10 1185.84 5 15.16 1898 2 2
4 10 1236.12 3 15.14 1972 2 2
5 10 1277.92 3 15.14 2035 2 2
6 10 1322.88 3 15.13 2097 2 2
7 10 1356.28 2 15.13 2133 2 2
8 3 1342.00 10 15.13 2116 2 2
9 3 1039.04 1 15.30 1720 2 2
10 5 1453.40 13 15.12 2266 2 2
11 7 2016.20 74 14.81 2824 2 2
12 13 769.44 18 15.14 1319 2 2
13 13 349.96 18 15.23 791 2 2
14 8 0.08 165 15.29 307 2 2

Cycle 4 GMT 18/ 1/2021 0:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 83 15.22 476 2 2
2 2 233.80 27 15.25 638 2 2
3 10 1068.28 4 15.19 1746 2 2
4 10 1114.32 3 15.18 1805 2 2
5 10 1153.60 2 15.18 1860 2 2
6 10 1182.48 2 15.18 1902 2 2
7 10 1255.24 2 15.18 2014 2 2
8 10 1292.72 2 15.18 2045 2 2
9 3 1304.00 9 15.15 2063 2 2
10 3 1038.92 1 15.30 1718 2 2
11 5 1319.32 9 15.17 2095 2 2
12 5 1449.40 13 15.12 2244 2 2
13 7 1524.12 74 15.02 2236 2 2
14 13 374.56 18 15.30 821 2 2
15 13 51.44 18 15.38 392 2 2
16 8 -0.04 165 15.35 305 2 2

Cycle 3 GMT 17/ 1/2021 1:36: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 55 15.27 471 2 2
2 3 788.16 -4 15.65 1 2 2
3 3 1508.64 14 15.14 2326 2 2
4 7 1895.64 74 14.87 2676 2 2
5 13 391.48 18 15.27 838 2 2
6 8 -0.04 165 15.33 308 2 2

Cycle 2 GMT 16/ 1/2021 11:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 30 15.29 469 2 2
2 10 1036.08 6 15.23 1696 2 2
3 10 1114.44 5 15.21 1805 2 2
4 10 1166.52 3 15.21 1874 2 2
5 10 1195.28 2 15.22 1931 2 2
6 3 1234.84 7 15.26 1968 2 2
7 3 1031.72 1 15.39 1710 2 2
8 5 1311.32 9 15.24 2068 2 2
9 5 1411.04 12 15.19 2197 2 2
10 5 1448.76 13 15.18 2257 2 2
11 7 1525.76 74 15.05 2232 2 2
12 13 289.76 18 15.35 705 2 2
13 8 0.08 165 15.38 297 2 2

Cycle 1 GMT 15/ 1/2021 12:22: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 26 15.53 421 2 2
2 10 1129.12 6 15.30 1805 2 2
3 3 1130.80 4 15.28 1832 2 2
4 3 1762.60 21 15.04 2607 2 2
5 7 1821.68 74 14.90 2573 2 2
6 13 596.68 18 15.24 1086 2 2
7 13 180.60 18 15.35 564 2 2
8 8 20.96 165 15.34 308 2 2

Cycle 0 GMT 15/ 1/2021 2:37: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 25 15.66 432 2 2
2 7 125.08 74 15.63 435 2 2
3 8 -0.16 240 15.60 265 2 6