SIO Argo AUX Buoyancy Pumping Time Series Data:



Serial= 3179 WMO= 7900809


Cycle 53 GMT 22/ 4/2024 7:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 25 15.16 571 2 29
2 10 1013.68 2 15.07 1797 2 23
3 7 2004.24 38 14.82 2920 2 19
4 13 1300.52 18 14.97 2075 2 23
5 13 673.20 18 15.10 1287 2 27
6 13 84.52 6 15.27 516 2 27
7 13 49.92 5 15.29 452 2 11
8 8 0.48 165 15.23 400 2 15

Cycle 52 GMT 12/ 4/2024 12:22: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 25 15.18 574 2 29
2 3 969.84 -1 15.52 1 2 29
3 7 2003.16 38 14.82 2920 2 18
4 13 1311.16 18 14.96 2090 2 22
5 13 713.48 18 15.08 1346 2 26
6 13 70.36 6 15.29 475 2 15
7 13 55.24 5 15.29 457 2 14
8 8 -0.20 165 15.23 397 2 16

Cycle 51 GMT 2/ 4/2024 16:50: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 26 15.18 560 2 29
2 7 2002.96 38 14.83 2922 2 18
3 13 1314.20 18 14.98 2100 2 22
4 13 673.40 18 15.11 1288 2 27
5 13 73.88 6 15.29 485 2 24
6 13 57.28 5 15.29 460 2 13
7 8 0.20 165 15.24 397 2 16

Cycle 50 GMT 23/ 3/2024 21:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 25 15.14 572 2 28
2 10 1001.44 2 15.06 1781 2 23
3 3 978.20 -1 15.51 1 2 23
4 7 2010.08 38 14.84 2947 2 18
5 13 1316.48 18 14.96 2125 2 22
6 13 642.64 18 15.12 1269 2 26
7 13 71.60 6 15.30 477 2 15
8 13 56.88 5 15.31 461 2 13
9 8 -0.04 165 15.25 400 2 16

Cycle 49 GMT 14/ 3/2024 1:30: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 25 15.17 558 2 28
2 7 2011.64 39 14.82 2931 2 18
3 13 1399.44 18 14.96 2208 2 22
4 13 718.72 18 15.09 1371 2 26
5 13 69.48 6 15.29 471 2 14
6 13 58.28 5 15.30 462 2 13
7 13 40.44 5 15.31 444 2 9
8 13 33.76 5 15.30 435 2 9
9 13 25.20 5 15.30 418 2 4
10 13 19.60 18 15.28 418 2 5
11 8 0.12 165 15.22 400 2 14

Cycle 48 GMT 4/ 3/2024 5:48: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 24 15.14 568 2 28
2 3 1051.12 1 15.08 1842 2 23
3 7 2003.68 38 14.83 2936 2 18
4 13 1314.48 18 14.97 2129 2 22
5 13 724.64 18 15.08 1381 2 26
6 13 91.64 18 15.27 533 2 29
7 8 -0.08 165 15.24 394 2 15

Cycle 47 GMT 23/ 2/2024 10:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 26 15.11 569 2 28
2 7 1749.00 38 14.86 2643 2 19
3 13 1248.52 18 14.96 2038 2 23
4 13 674.08 18 15.07 1317 2 26
5 13 103.96 18 15.23 546 2 29
6 8 0.40 165 15.21 396 2 16

Cycle 46 GMT 22/ 2/2024 8:27: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 26 15.11 572 2 28
2 7 1779.60 38 14.86 2678 2 19
3 13 1286.16 18 14.95 2079 2 22
4 13 653.32 18 15.07 1288 2 26
5 13 59.04 18 15.26 456 2 12
6 13 34.08 18 15.25 430 2 7
7 8 -0.12 165 15.19 401 2 16

Cycle 45 GMT 21/ 2/2024 6:26: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 24 15.13 578 2 27
2 10 1009.48 3 15.03 1798 2 22
3 7 1735.48 38 14.88 2613 2 19
4 13 1268.88 18 14.97 2059 2 22
5 13 674.96 18 15.10 1312 2 26
6 13 59.36 18 15.27 454 2 13
7 8 0.08 165 15.21 396 2 22

Cycle 44 GMT 20/ 2/2024 4:35: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1094.92 8 14.96 1896 2 20
2 10 1192.00 6 14.93 2051 2 20
3 10 1264.00 4 14.92 2138 2 20
4 10 1307.00 3 14.93 2220 2 20
5 3 1287.96 8 14.95 2153 2 21
6 3 1027.68 1 15.14 1831 2 21
7 7 2003.88 38 14.83 2915 2 18
8 13 1272.76 18 14.98 2054 2 22
9 13 725.92 18 15.10 1355 2 26
10 13 115.88 18 15.26 563 2 29
11 8 0.00 165 15.23 402 2 12

Cycle 43 GMT 10/ 2/2024 8:50: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 790.00 -6 15.56 0 2 2
2 7 2008.52 38 14.85 2944 2 17
3 13 1467.52 18 14.96 2305 2 20
4 13 754.40 18 15.12 1416 2 25
5 13 130.92 7 15.28 595 2 27
6 8 -0.12 165 15.26 396 2 11

Cycle 42

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 765.68 -7 15.57 1 2 2
2 3 975.20 -1 15.61 1 2 2
3 7 2010.04 38 14.84 2924 2 17
4 13 1389.16 18 14.96 2193 2 21
5 13 705.92 18 15.09 1351 2 25
6 13 74.12 6 15.30 505 2 24
7 13 58.08 5 15.30 461 2 11
8 13 49.12 5 15.31 454 2 12

Cycle 41

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 771.44 -7 15.58 1 2 2
2 7 2002.92 38 14.85 2938 2 17
3 13 1366.32 18 14.97 2179 2 21
4 13 730.20 18 15.11 1389 2 25
5 13 101.96 7 15.30 544 2 29
6 13 52.52 5 15.32 448 2 12

Cycle 40

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 764.60 -7 15.58 1 2 2
2 3 974.20 -1 15.60 1 2 2
3 7 2007.84 38 14.86 2931 2 18
4 13 1290.16 18 15.00 2088 2 22
5 13 703.52 18 15.11 1350 2 26
6 13 71.56 6 15.31 486 2 22
7 13 43.56 5 15.32 439 2 8

Cycle 39

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 752.04 -7 15.58 1 2 2
2 3 951.20 -1 15.62 1 2 2
3 7 2008.80 38 14.85 2924 2 18
4 13 1289.16 18 15.00 2073 2 22
5 13 712.80 18 15.11 1365 2 26
6 13 68.88 6 15.30 472 2 17
7 13 54.96 5 15.33 458 2 12

Cycle 38

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 752.80 -7 15.57 1 2 2
2 3 959.52 -1 15.59 1 2 2
3 7 2011.16 39 14.86 2961 2 18
4 13 1308.72 18 15.00 2118 2 23
5 13 725.16 18 15.11 1382 2 26
6 13 87.76 6 15.31 530 2 28

Cycle 37

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 758.76 -7 15.57 0 2 2
2 3 968.28 -1 15.60 1 2 2
3 7 2007.12 39 14.84 2945 2 19
4 13 1301.16 18 14.98 2108 2 23
5 13 676.08 18 15.11 1321 2 27
6 13 80.24 6 15.30 512 2 27

Cycle 36

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 760.96 -7 15.58 1 2 2
2 3 968.20 -1 15.61 1 2 2
3 7 2009.00 38 14.85 2931 2 19
4 13 1263.40 18 15.00 2034 2 24
5 13 684.96 18 15.12 1334 2 27
6 13 84.28 6 15.30 517 2 28

Cycle 35

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 763.16 -7 15.59 0 2 2
2 3 971.28 -1 15.62 1 2 2
3 7 2008.08 38 14.86 2952 2 19
4 13 1309.44 18 14.99 2113 2 23
5 13 680.60 18 15.13 1313 2 27
6 13 77.20 6 15.31 513 2 26

Cycle 34

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 788.36 -6 15.59 1 2 2
2 3 974.32 -1 15.62 1 2 2
3 7 2003.24 38 14.86 2944 2 19
4 13 1302.84 18 15.01 2108 2 23
5 13 718.96 18 15.12 1378 2 27
6 13 79.76 6 15.32 506 2 28

Cycle 33

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 783.20 -6 15.59 1 2 2
2 3 972.48 -1 15.62 1 2 2
3 7 2009.16 38 14.88 2937 2 19
4 13 1395.40 18 15.00 2202 2 23
5 13 760.80 18 15.11 1430 2 27
6 13 108.56 7 15.31 562 2 29
7 13 54.60 5 15.34 451 2 14

Cycle 32

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 753.44 -7 15.59 1 2 2
2 3 959.96 -1 15.63 1 2 2
3 7 2009.32 39 14.86 2932 2 19
4 13 1303.00 18 15.01 2082 2 24
5 13 677.00 18 15.14 1311 2 27
6 13 81.44 6 15.33 515 2 28
7 13 60.36 5 15.34 457 2 15

Cycle 31

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 756.08 -7 15.59 0 2 2
2 3 965.96 -1 15.62 0 2 2
3 7 2004.40 38 14.87 2942 2 19
4 13 1257.40 18 15.02 2049 2 24
5 13 666.36 18 15.14 1309 2 27
6 13 75.12 6 15.32 516 2 26

Cycle 30

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 753.88 -7 15.59 1 2 2
2 3 955.00 -1 15.62 1 2 2
3 7 2009.84 38 14.87 2938 2 20
4 13 1312.28 18 15.00 2120 2 24
5 13 726.12 18 15.12 1388 2 28
6 13 78.52 6 15.32 517 2 27

Cycle 29

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 753.52 -7 15.60 1 2 2
2 3 958.52 -1 15.62 1 2 2
3 7 2009.20 38 14.88 2960 2 20
4 13 1280.68 18 15.02 2080 2 24
5 13 706.32 18 15.13 1364 2 27
6 13 94.68 6 15.32 532 2 30

Cycle 28

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 761.68 -7 15.60 1 2 2
2 3 969.28 -1 15.63 0 2 2
3 7 2009.68 38 14.88 2923 2 19
4 13 1273.64 18 15.04 2038 2 24
5 13 649.24 18 15.16 1257 2 28
6 13 83.12 6 15.32 497 2 28

Cycle 27

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 824.68 -5 15.60 2 2 2
2 7 2007.12 39 14.88 2952 2 20
3 13 1270.88 18 15.03 2063 2 24
4 13 684.04 18 15.15 1325 2 28
5 13 62.68 6 15.34 476 2 15
6 13 46.24 5 15.35 448 2 13

Cycle 26

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 764.76 -7 15.61 1 2 2
2 3 964.48 -1 15.64 1 2 2
3 7 2006.64 38 14.88 2951 2 20
4 13 1292.12 18 15.03 2100 2 24
5 13 698.64 18 15.15 1348 2 28
6 13 204.52 10 15.28 700 2 31

Cycle 25

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 764.84 -7 15.61 1 2 2
2 3 980.40 -1 15.63 1 2 2
3 7 1720.40 38 14.98 2579 2 21
4 13 1230.08 18 15.09 1989 2 24
5 13 636.72 18 15.18 1251 2 27
6 13 66.40 6 15.35 475 2 15

Cycle 24

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 840.20 -5 15.66 1 2 2
2 3 979.24 -1 15.68 0 2 2
3 7 2003.64 38 14.89 2944 2 19
4 13 1209.84 18 15.05 1998 2 23
5 13 610.80 18 15.17 1241 2 27
6 13 68.52 6 15.34 487 2 18

Cycle 23

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 791.96 -6 15.61 1 2 2
2 3 980.36 -1 15.65 1 2 2
3 7 849.36 39 15.31 1525 2 25
4 13 830.64 18 15.29 1521 2 26
5 13 351.08 14 15.38 897 2 29
6 13 52.64 5 15.47 453 2 13
7 13 43.68 5 15.48 444 2 11

Cycle 22

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 770.48 -7 15.61 1 2 2
2 7 2011.60 38 14.91 2951 2 18
3 13 1234.12 18 15.06 2026 2 23
4 13 728.60 18 15.15 1393 2 27
5 13 80.04 6 15.35 520 2 27
6 13 44.96 5 15.36 443 2 11

Cycle 21

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 802.92 -6 15.62 1 2 2
2 3 980.24 -1 15.65 1 2 2
3 7 2004.60 38 14.91 2921 2 19
4 13 1295.48 18 15.05 2070 2 23
5 13 712.28 18 15.16 1346 2 27
6 13 69.52 6 15.34 485 2 17

Cycle 20

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 788.20 -6 15.62 1 2 2
2 3 981.32 -1 15.64 1 2 2
3 7 1695.40 38 15.02 2561 2 21
4 13 1225.16 18 15.10 2013 2 23
5 13 630.60 18 15.21 1259 2 26
6 13 55.00 5 15.40 450 2 13

Cycle 19

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 25 15.30 581 2 30
2 3 109.36 -26 15.61 1 2 30
3 3 559.44 -13 15.64 1 2 30
4 7 2004.56 38 14.90 2940 2 18
5 13 1402.76 18 15.02 2223 2 22
6 13 631.52 18 15.18 1264 2 26
7 13 63.52 6 15.35 471 2 13
8 13 52.16 5 15.36 462 2 12

Cycle 18

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 25 15.23 581 2 31
2 7 2008.32 38 14.91 2928 2 19
3 13 1192.24 18 15.08 1961 2 24
4 13 666.88 18 15.18 1311 2 27
5 13 69.96 6 15.35 498 2 21
6 13 55.36 5 15.37 465 2 14

Cycle 17 GMT 30/ 5/2023 23:59: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 25 15.24 570 2 31
2 7 2003.32 38 14.93 2932 2 20
3 13 1241.28 18 15.07 2033 2 24
4 13 689.64 18 15.17 1340 2 28
5 13 62.88 6 15.37 459 2 15
6 8 0.32 165 15.31 404 2 17

Cycle 16 GMT 21/ 5/2023 4:29: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 25 15.25 575 2 31
2 7 2004.52 38 14.94 2930 2 20
3 13 1267.00 18 15.08 2042 2 24
4 13 666.68 18 15.19 1281 2 28
5 13 83.12 6 15.37 498 2 28
6 8 0.00 165 15.31 402 2 17

Cycle 15 GMT 11/ 5/2023 9: 3: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 25 15.23 587 2 30
2 7 2005.28 38 14.94 2936 2 20
3 13 1230.04 18 15.09 1998 2 24
4 13 708.04 18 15.18 1365 2 28
5 13 68.28 6 15.36 491 2 20
6 13 56.32 5 15.36 468 2 14
7 8 0.08 165 15.32 410 2 15

Cycle 14 GMT 1/ 5/2023 13: 7: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 25 15.30 566 2 29
2 7 2008.24 38 14.94 2932 2 19
3 13 1228.36 18 15.09 1989 2 24
4 13 781.48 18 15.17 1424 2 27
5 13 55.56 5 15.38 437 2 14
6 13 48.52 5 15.39 427 2 13
7 13 42.00 5 15.39 408 2 11
8 8 0.16 165 15.31 403 2 17

Cycle 13 GMT 21/ 4/2023 17:32: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 25 15.28 570 2 29
2 7 1405.08 38 15.15 2217 2 23
3 13 1130.64 18 15.19 1897 2 25
4 13 537.32 18 15.30 1141 2 29
5 13 61.40 6 15.45 473 2 15
6 8 0.00 165 15.38 406 2 15

Cycle 12 GMT 11/ 4/2023 20:38: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 25 15.28 564 2 29
2 3 977.40 -1 15.66 0 2 18
3 7 1513.48 38 15.12 2349 2 23
4 13 1222.40 18 15.16 2009 2 25
5 13 519.20 18 15.29 1115 2 29
6 13 50.04 5 15.43 446 2 13
7 8 0.92 165 15.37 405 2 14

Cycle 11 GMT 1/ 4/2023 23:31: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 25 15.31 565 2 29
2 7 1727.36 38 15.06 2590 2 21
3 13 1192.44 18 15.16 1949 2 25
4 13 583.44 18 15.26 1175 2 29
5 13 84.80 6 15.41 504 2 29
6 8 0.36 165 15.35 395 2 13

Cycle 10 GMT 23/ 3/2023 1:51: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 25 15.27 576 2 28
2 3 1029.32 1 15.22 1830 2 23
3 7 1464.64 39 15.15 2286 2 22
4 13 1054.44 18 15.21 1791 2 26
5 13 500.44 18 15.30 1091 2 29
6 8 0.08 165 15.38 395 2 15

Cycle 9 GMT 13/ 3/2023 4:43: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 23 15.26 558 2 28
2 10 1034.56 2 15.20 1835 2 24
3 7 1916.36 38 14.99 2831 2 20
4 13 1255.00 18 15.11 2031 2 24
5 13 667.40 18 15.21 1303 2 28
6 13 68.56 6 15.39 492 2 24
7 8 0.16 165 15.33 401 2 16

Cycle 8 GMT 3/ 3/2023 6:51: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 15.25 569 2 29
2 3 850.36 -3 15.61 0 2 29
3 3 943.88 -1 15.65 0 2 29
4 7 2010.64 74 14.84 2916 2 20
5 13 439.80 18 15.26 978 2 29
6 8 0.28 165 15.33 387 2 17

Cycle 7 GMT 21/ 2/2023 11:59: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 24 15.25 561 2 28
2 10 1010.24 2 15.19 1780 2 23
3 3 972.60 -1 15.67 0 2 23
4 7 1690.28 74 14.91 2547 2 22
5 13 225.40 18 15.32 714 2 30
6 8 0.56 165 15.33 395 2 17

Cycle 6 GMT 20/ 2/2023 11:39: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 24 15.27 561 2 28
2 7 1523.60 75 14.96 2349 2 22
3 13 145.52 18 15.36 604 2 30
4 8 -0.04 165 15.34 389 2 15

Cycle 5 GMT 19/ 2/2023 11:54: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 24 15.28 514 2 28
2 7 1523.44 74 14.98 2321 2 22
3 13 72.36 18 15.40 463 2 27
4 8 0.08 165 15.36 365 2 17

Cycle 4 GMT 18/ 2/2023 11:49: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 24 15.29 528 2 28
2 3 1020.80 1 15.28 1800 2 21
3 7 1506.48 75 14.98 2296 2 23
4 13 58.52 18 15.40 420 2 15
5 8 0.08 165 15.35 355 2 16

Cycle 3 GMT 17/ 2/2023 11:55: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 23 15.30 533 2 28
2 3 1023.56 1 15.30 1803 2 22
3 7 1506.80 74 14.99 2303 2 23
4 13 137.64 18 15.38 565 2 31
5 8 0.16 165 15.36 354 2 17

Cycle 2 GMT 16/ 2/2023 12:16: 0

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 31 15.36 533 2 29
2 3 780.76 -4 15.71 0 2 29
3 3 918.08 -2 15.72 0 2 29
4 7 1510.08 74 15.00 2301 2 23
5 13 58.92 18 15.41 422 2 14
6 8 0.04 165 15.37 352 2 12

Cycle 1 GMT 15/ 2/2023 12:13: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 26 15.56 460 2 19
2 7 993.36 74 15.19 1655 2 27
3 8 0.08 165 15.43 355 2 14

Cycle 0 GMT 15/ 2/2023 1:40: 1

Pump Count Mission Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.92 25 15.70 526 2 8
2 7 179.64 74 15.65 532 2 11
3 8 -0.08 240 15.62 288 2 20